IONX CMUE6-A Communications Manager Unit User Manual Working T4 Install

IONX LLC Communications Manager Unit Working T4 Install

Exhibit D Users Manual per 2 1033 b3

Download: IONX CMUE6-A Communications Manager Unit User Manual Working T4 Install
Mirror Download [FCC.gov]IONX CMUE6-A Communications Manager Unit User Manual Working T4 Install
Document ID4029990
Application IDGzy4OEhnEpKaFVPlI4tPTg==
Document DescriptionExhibit D Users Manual per 2 1033 b3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize227.19kB (2839883 bits)
Date Submitted2018-10-09 00:00:00
Date Available2018-10-09 00:00:00
Creation Date2018-07-10 11:34:27
Producing SoftwareMicrosoft® Word 2013
Document Lastmod2018-07-10 11:34:27
Document TitleWorking T4 Install
Document CreatorMicrosoft® Word 2013
Document Author: Heagerty, David

IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
IONX Technical Data
Installation Manual
for the
Edge E-Series
Communications Management Unit (CMU)
IONX LLC
515 S. Franklin St.
West Chester, PA 19382
www.ionxlive.com
484.653.2600
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 1 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
1) Warnings
These instructions are not designed to imply or replace any operating or safety rules.
It is the responsibility of the installer to understand and follow all company safety practices.
WARNING In order to comply with hazardous classification, only those items
specifically listed can be used and must be used only as shown. Substitution of components
may affect intrinsic safety.
WARNING Installation shall be carried out in accordance with the applicable code of
practice by suitably-trained personnel.
WARNING Repair of this equipment shall be carried out in accordance with the
applicable code of practice.
WARNING Any machining, drilling, and/or sanding related to the installation of this
system should be pre-approved by the authorized department before work is started.
WARNING If the equipment is likely to come into contact with aggressive substances,
then it is the responsibility of the user to take suitable precautions that prevent it from being
adversely affected, thus ensuring that the type of protection is not compromised.
WARNING RF Device: Unit cannot be painted or coated with any material. Coating can
adversely affect the performance of the device. Unit shall be masked appropriately if post
installation coating is required.
WARNING EXPLOSION HAZARD: The equipment temperature Class is T4 and only
certified for use in ambient temperatures. Product is rated from -40C to +55C and should not
be used outside this range in an explosive environment.
WARNING EXPLOSION HAZARD: Installation shall be carried out in accordance with
the applicable code of practice by suitable trained personnel.
WARNING POTENTIAL ELECTROSTATIC CHARGING HAZARD: Under certain extreme
circumstances, the non-metallic parts incorporated in the enclosure of this equipment may
generate an ignition-capable level of electrostatic charge. Therefore the equipment shall not be
installed in a location where the external conditions are conducive to the build-up of electrostatic
charge on such surfaces. This is particularly important if the equipment is installed in a zone 0
location.
WARNING POTENTIAL ELECTROSTATIC CHARGING HAZARD: Suitable for hose down
cleaning only. Do not clean unit with a dry cloth. Static can be generated when two dry parts are
rubbed together.
WARNING
DO NOT OPEN WHEN EXPLOSIVE ATMOSPHERE IS PRESENT. Battery
replacement shall be done in an area known to be non-hazardous. Use only replaceable battery
pack IONX model 303382 (19 mAH) or 303406 (76 mAH). See battery replacement procedure in
Appendix F.
WARNING Products contain Primary Lithium batteries. Proper disposal procedures are
required at end of life conditions. Use local regulatory disposal method for lithium Thionyl
chloride batteries. For example, disposal procedure 49 CFR 173.185.
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 2 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
1) Avertissements
Ces instructions ne sont pas conçues pour impliquer ou remplacer des règles d'utilisation ou de sécurité.
Il est de la responsabilité de l'installateur de comprendre et de suivre toutes les pratiques de sécurité de l'entreprise.
Instructions complètes pour utiliser CMU en français en attente.
AVERTISSEMENT Afin de se conformer à la classification des matières dangereuses,
seuls les éléments spécifiquement énumérés peuvent être utilisés et doivent être utilisés uniquement
comme indiqué. La substitution de composants peut affecter la sécurité intrinsèque.
AVERTISSEMENT L'installation doit être effectuée conformément au code de pratique
applicable par du personnel dûment formé.
AVERTISSEMENT La réparation de cet équipement doit être effectuée conformément au
code de pratique applicable.
AVERTISSEMENT Tout usinage, perçage et / ou ponçage lié à l'installation de ce système
doit être préalablement approuvé par le service autorisé avant le début des travaux.
AVERTISSEMENT Si l'équipement est susceptible d'entrer en contact avec des substances
agressives, il est de la responsabilité de l'utilisateur de prendre les précautions appropriées qui empêchent
qu'il soit affecté de manière négative, garantissant ainsi que le type de protection n'est pas compromis.
ATTENTION Dispositif RF: L'unité ne peut être peinte ou revêtue d'aucun matériau. Le
revêtement peut nuire aux performances de l'appareil. L'unité doit être masquée de manière appropriée si
un revêtement post-installation est requis.
ATTENTION DANGER D'EXPLOSION: La classe de température de l'équipement est T4 et
seulement certifiée pour une utilisation à des températures ambiantes. Le produit est évalué de onnement explosif.
ATTENTION DANGER D'EXPLOSION: L'installation doit être effectuée conformément au code
de pratique en vigueur par du personnel qualifié.
ATTENTION DANGER DE CHARGE ÉLECTROSTATIQUE POTENTIEL: Dans certaines
circonstances extrêmes, les pièces non métalliques incorporées dans l'enveloppe de cet équipement
peuvent générer un niveau de charge électrostatique capable d'amorçage. Par conséquent, l'équipement
ne doit pas être installé dans un endroit où les conditions externes favorisent l'accumulation de charges
électrostatiques sur ces surfaces. Ceci est particulièrement important si l'équipement est installé dans un
emplacement de la zone 0.
ATTENTION DANGER DE CHARGE ÉLECTROSTATIQUE POTENTIEL: Convient uniquement au
nettoyage par tuyau. Ne nettoyez pas l'appareil avec un chiffon sec. Statique peut être généré lorsque deux
parties sèches sont frottées ensemble.
ATTENTION NE PAS OUVRIR LORSQU'UNE ATMOSPHÈRE EXPLOSIVE EST PRÉSENTE. Le
remplacement de la batterie doit être effectué dans une zone connue comme non dangereuse. Utilisez
uniquement une batterie remplaçable IONX modèle 303382 (19 mAH) ou 303406 (76 mAH). Voir la procédure
de remplacement de la batterie à l'annexe F.
ATTENTION Les produits contiennent des batteries au lithium primaire. Des procédures
d'élimination appropriées sont requises en fin de vie. Utiliser une méthode d'élimination réglementaire
locale pour les piles au lithium-chlorure de thionyle. Par exemple, procédure d'élimination 49 CFR 173.185.
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 3 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
2 Unpacking the CMU
Required Tools/Materials
Tool Name
(Part No)
Description
3/8” Magnetic Drive
Socket
Securing self-drilling screws
T-27 Tamper-Resistant
Torx driver
Securing CMU to bracket
If using a knife to cut the tape, do not let the blade extend more than ½ inch inside of the
cardboard box.
2.1
2.2
Inspect shipping box/s to make sure there is no damage.
Carefully unpack the shipping box making sure to open the top of the box.
There will be instruction guide/s for modules associated with the system order.
Open shipping box/s and verify that the internal contents match the shipping receipt.
Contact IONX Support Center (Appendix C) in the event of any above problems.
2.3
[WDL1]
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 4 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
3 Activating the CMU
Warning: NFC tag reader is not for use in potentially explosive atmospheres. Activate the CMU
on a benchtop in a non-hazardous area.
ATTENTION: Le lecteur d'étiquette NFC ne doit pas être utilisé dans des atmosphères
potentiellement explosives. Activer la CMU sur une paillasse dans une zone non dangereuse.
3.1 Before starting
3.1.1 Confirm your email address is set-up in the IONX TARA system by emailing
tara@ionxlive.com with “help” in the subject line.
3.1.2 If there is no reply, contact the IONX Support Center (Appendix C) to get your email
address set-up to use TARA and IONXlive.net.
3.1.3 Download the IONX E-series application for NFC reader.
3.1.4 Start Ionx application.
3.2 Place NFC reader device near yellow label of CMU. This wakes the CMU from deep sleep.
3.3 Confirm device wake up message was received using IONX E-series application.
3.4 Alternately, some CMU devices may be activated by removing a magnet, under tape, on the top
surface of the CMU.
3.5 Attach the CMU to the mounting plate or car using the supplied hardware.
3.6 See mechanical installation drawings in Appendix A for specific mounting details
3.7 If the CMU is being mounted to a hatch, be sure the hatch is closed after the CMU has been
mounted (Figure 6).
Figure 6: Final CMU connection to mounting plate
3.8 Associate the CMU with the car according to Section 4.
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 5 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
4 Associating the CMU
The IONX Totally Autonomous Reporting Agent (TARA) is used to associate the car number with the
CMU. This is completed by email using an email-enabled smart phone or any computer with email
access.
4.1 Before starting
4.1.1 Confirm your email address is set-up in the IONX TARA system by emailing
tara@ionxlive.com with “help” in the subject line.
4.1.2 If there is no reply within 60 minutes, contact the IONX Support Center
(Appendix D) to get your email address set-up to use TARA and IONXlive.net.
4.2 Associating the Car Number to the CMU
4.2.1 Start a new email message


To: type TARA@IONXLive.com
Subject: type
 ‘I’ or ‘i’
 period ‘.’
 The serial number of the CMU
 Period ‘.’
 The Car initials
 Period ‘.’
 The Car number which the CMU is installed on
 Period ‘.’
 Company Name
Example: I.SerialNumber.CarInitial.CarNumber.CompanyName
Example: I.E6AA015000.ABCX.1234.ABCRailroad
4.2.2
4.2.3
Send the message
A response message confirming the installation will be sent from TARA (Figure
7)
Success!
Unit E6AA015000 now installed on ABCX 1234
associated to ABC. If this is not correct Contact IONX Support at– 484-653-2600.
**This is an automated report email, please do
not reply directly to this message as it will be
discarded.
Figure 7: Sample Installation Response
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 6 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
4.2.4
The CMU is associated with the car number. The installation is complete. The car now
can be released into service.
4.3 For replacing a device on a car, start a new email message


To: type TARA@IONXLive.net
Subject: type
‘R’ or ‘r’
period ‘.’
The serial number of the old replaced CMU
Period ‘.’
The serial number of the new CMU being installed
Period ‘.’
The Car initials
Period ‘.’
The Car number which the CMU is installed on
Example: R.OldSerialNumber.NewSerialNumber.CarInitial.CarNumber
Example: R.E5AC011001.E4AB011000.ABCX.1234
4.3.1
An email response message confirming the replacement will be sent from TARA.
4.3.2
To see details of all TARA email service commands, go to Appendix C.
4.4 Using the TARA web site
4.4.1
Click on the link below and log in using the same credentials you use to access the IONX web
site:https://www.ionxlive.net/IonxLiveMassTARA/
Note: If you receive the error message ‘User is not a valid TARA user’, please contact IONX
support to be added to the list of valid TARA users.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 7 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
4.4.2
After logging in, you should see the following screen. This is the ‘Install’ tab and should be used
if installing a device on a new car. If replacing a device on a car, please see the ‘Replace’
command instructions in section 6.3.3.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 8 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
4.4.3
If installing only one device, fill in the serial number of the CMU to be installed, the car name
and number (format ABCD 123456) and choose the customer name from the dropdown. Then
press the ‘Install’ button.
The following message should be displayed:'Success! Unit  is now installed on  associated to
. If this is not correct - Contact customer support at IONX - 484-6532600.'
If the above message is not displayed and an error message displayed which you do not
understand, please capture the message and send to IONX Support for further investigation.
Note that IONX installers will have access to all customers from the dropdown list.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 9 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
4.4.4
If installing multiple devices, please use the section at the bottom of the page. Up to five (5)
devices can be installed at one time. Success messages will be displayed for all installed devices
and they will be removed from the table. Unsuccessful installs will still remain in the table for
correction and error messages will be displayed for them.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 10 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
4.5 Other TARA Web Site Commands.
The TARA web site also can be used to send other TARA commands namely uninstall, replace, change,
wireless sensor monitor (WSM), detailed status and change battery (certain customers). Below is a short
description of each function. Note that descriptions for TARA commands not used during installation can
be found in Appendix B.
4.5.1
Uninstall
Used when uninstalling IONX CMU devices from cars.
Enter the serial number and car name for the device to be uninstalled. Check the RMA check box
if the device is to be returned to IONX and press the ‘Uninstall’ button. If the RMA checkbox is
selected, the unit will be moved to the IONX uninstalled fleet, otherwise it will be moved to the
customer uninstalled fleet. Note that the car name entered must be in the format ‘ABCD
123456’ unless the customer is designated as a European customer. European customers may
enter the car name in any format.
For multiple uninstalls, up to 5 devices can be uninstalled using the ‘Uninstall Multiple Devices’
table at the bottom of the web page above.
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 11 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
4.5.2
Change battery. See Appendix F.
4.5.3
Replace
Used when replacing an IONX CMU device on a car with another IONX CMU.
Enter old CMU serial number (to be replaced), new CMU serial number (replacement)
and car name. Press the ‘Replace’ button.
Note that the car name must be of the format ‘ABCD 123456’ unless the customer is
designated as a European customer.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 12 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
4.5.4
Wireless Sensor Monitor (WSM) – For information purposes only.
Car sets are CMU devices plus Wireless Sensor Nodes (WSNs). WSM is used to
determine if a CMU is awake and all WSNs have joined the network.
Following the instructions on the web page and then enter the IONX CMU serial number
and press the ‘Monitor’ button.
A table of the WSNs (serial number, node number and status) for the car set should be
displayed.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 13 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
5 Miscellaneous
Translations available upon request.
Traductions disponibles sur demande.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 14 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Appendix A: Mechanicals
A.1
E4S and E5S Dimensions
Warning: Mounting bracket is required for CMU-E4S and CMU-E5S models when commissioning for use
in potentially explosive atmosphere. IONX part number 302262, Isolation mount bracket for ExS, is
approved for use in explosive atmosphere.
Attention: Le support de montage est requis pour les modèles CMU-E4S et CMU-E5S lors de la mise en
service pour une utilisation dans une atmosphère potentiellement explosive. Le numéro de pièce IONX
302262, support de montage d'isolation pour ExS, est approuvé pour une utilisation en atmosphère
explosive.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 15 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
A.2
E4S and E5S Installation with Bracket
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 16 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
A.3
E4S and E5S Installation with Magnetic Bracket and Safety Tether
Required Tools/Materials for Safety Tether
Tool Name
(Part No)
Description
Electricians’ Crimping
Pliers
Crimps ferrules to wire rope
1/16 inch or 1.58 mm
Ferrules - 2 per tether
Ferrules for wire rope
1/16 inch or 1.58 mm
Wire Rope – 6 foot each
Wire rope for safety tether
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 17 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
STEP 1 CHOOSE A LOCATION FOR THE CMU BRACKET THAT WILL SEE A CLEAR VIEW OF THE SKY. THIS
WILL ENSURE GOOD GPS RECEPTION.
STEP 2 ENSURE MOUNTING SURFACE IS FREE OF ANY IMPERFECTIONS THAT MAY PREVENT THE
MAGNETS FROM MATING FLUSH AND SECURING TO THE RAILCAR SURFACE.
STEP 3 THREAD THE WIRE ROPE THROUGH THE FERRULE AND AROUND ONE OF THE BRACKET FEET AND
BACK THROUGH THE FERRULE AS SHOWN BELOW.
MAKE THE WIRE LOOP TAUT AROUND THE BRACKET FOOT SO THE SAFETY TETHER CAN NOT BE
REMOVED OVER THE MAGNET. (SEE SECOND PHOTO BELOW) USE ELECTRICIAN PLIERS TO CRIMP THE
FERRULE.
STEP 4 TAKE CAUTION THAT THE TETHER DOES NOT CAUSE A TRIPPING HAZARD OR GET TANGLED IN
OTHER EQUIPMENT.
STEP 5 IF THE ENTIRE LENGTH OF THE WIRE ROPE IS NOT NEEDED, PULL THE EXCESS WIRE THROUGH
THE SECOND FERRULE, CRIMP, AND CUT OFF ANY EXCESS WIRE ROPE.
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 18 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
DIFFERENT TYPES OF PLIERS THAT CAN BE USED - SHOWS THE FERRULES IN EACH PLIER TYPE
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 19 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
A.4
E4S and E5S Dome Mounted
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 20 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
A.5
E4S and E5S J-Bolt Mounting
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 21 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 22 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
A.6
E4X, E5X and E6S Dimensions
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 23 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
A.7
E4X, E5X and E6S Installation with Bracket
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 24 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
A.8
E4X, E5X, and E6X with the mounting bracket
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 25 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
A.9
E4X, E5X, and E6X Dome Mounted
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 26 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Appendix B: Validating the Installation
Validating the installation is an optional step that will allow new installers to confirm the installation was
completed correctly. Validation is done with the IONX Totally Autonomous Reporting Agent (TARA) or
with IONXlive.net.
B.1.
Before starting:
Contact the IONX Support Center (Appendix D) to make sure your email address is registered
to use TARA and IONXlive.net.
B.2
B.2.1
B.2.2
Install Validation using IONXlive.net
Navigate to www.IONXlive.net and login if a username and password has been supplied.
Using the tracking navigator tree view on the left (See Figure 8):
B.2.2.1 Find the unit being validated and click on the name.
B.2.2.2 If you have not associated the CMU with the car name the unit will appear as
the serial number on the website.
B.2.2.3 If you have associated the car with the CMU the unit will appear as the car name
on the website.
B.2.2.4 If you cannot find the unit serial number or the car name in the tracking
navigator please contact the IONX Support Center (Appendix D).
Figure 8: Selection of a car with the tracking navigator
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 27 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
B.2.3
Select serial number or the car name. The message pane in the lower right will update
with the latest messages (Figure 9)
Figure 9: IONXlive.net displaying the latest asset information
B.2.4
B.2.5
B.3
If the installation was completed successfully, there should be a recent message from
the device. If the message does not show up on the website please contact the IONX
Support Center (Appendix D).
If a recent message is shown on IONXlive.net the installation was successful.
Install validation using TARA
Note: TARA is case insensitive. Upper case or lower case letters may be used in the subject line
or address.
B.3.1
Find the device serial number of the CMU being installed.
B.3.2
Start a new email message


To: type TARA@IONXLive.com
Subject: type ‘M’ or ‘m’ followed by a period ‘.’ And the CMU serial number
(See Figure 11)
Example: M.SerialNumber
Example: M.GA0004522A
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 28 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Figure 11: Sample Email Request to TARA
B.3.3
Send the email message
B.3.3.1 A response email will be sent from TARA confirming:
B.3.3.2 The subscription to TARA for the CMU
B.3.3.4 Example Below-Figure 12
Figure 12: Sample Email Response from TARA
B3.4
A second email will be sent from TARA, which is the most recent location report sent from
the CMU.
B.3.4.1 The message will likely show a location message from where the IONX production
facility is located.
B.3.4.2 Disregard this message
B.3.4.3 See Figure 13
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 29 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Figure 13: Sample TARA Message
B.3.5
TARA now is configured to monitor the CMU. Repeat the process for all the CMUs being
installed today
B.3.6
The installation was successful if you find TARA emails for power up messages time
stamped the same time the CMU was activated.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 30 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Appendix C: Replace command
The IONX Totally Autonomous Reporting Agent (TARA) is used to associate the car number with the
CMU. If an IONX GPS device has already been installed on the car and associated, the replace command
will be used. This is completed by email using an email-enabled smart phone or any computer with email
access.
C.1 Before starting
C.1.1
Confirm your email address is set-up in the IONX TARA system by emailing
tara@ionxlive.com with “help” in the subject line.
C.1.2
If there is no reply, contact the IONX Support Center (Appendix D) to get your
email address set-up to use TARA and IONXlive.net.
C.2 Associating the Car Number to the CMU.
C.2.1
Start a new email message


To: type TARA@IONXLive.net
Subject: type
‘R’ or ‘r’
period ‘.’
The serial number of the old replaced CMU
Period ‘.’
The serial number of the new CMU being installed
Period ‘.’
The Car initials
Period ‘.’
The Car number which the CMU is installed on
Example: R.OldSerialNumber.NewSerialNumber.CarInitial.CarNumber
Example: R.1234A. E6AA015000.ABCX.1234
C.2.2
Send the message
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 31 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
C.2.3
A response message confirming the installation will be sent from TARA. See example
email in below:
Success!
Unit 1234A has been replaced by E6AA015000 for
ABCX.1234. If this has been done in error Contact Customer Service at IONX - 484-653-2600.
**This is an automated report email, responding to
this message will re-issue the same command.
Sample Installation Response
C.2.4
The CMU is associated with the car number. The installation is complete. The car
now can be released into service.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 32 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Appendix D: General Information
D1. IONX Support Center
An IONX Customer Service Representative can be reached via the following communication
methods:
Phone (local):
+1-484-653-2600, press 1 for Customer Service
Phone (toll-free):
+1-888-519-4050
Fax:
+1-484-653-2601
Email:
supportcenter@ionxlive.com
D2. Forcing the CMU to call
If there is a problem verifying messages on the website or through TARA, the CMU can be forced to call
for 24 hours after removing the installation magnet. Place the installation magnet onto the indentation,
where it was located, at the time of shipping for 30-seconds then remove. The CMU should send a
report within 15-minutes. If TARA is active for the CMU and no reports are received by email or on the
website, contact the IONX Support Center.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 33 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
D4. Overview of CMU physical features
IONX Contact
Information
Intrinsic Safety
Certification
Reed Switch
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 34 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Appendix E: Trouble Shooting
E1. Missed Wake-up Message
If the wakeup message does not show up through TARA within 30-minutes of the magnet being
removed, another message can be forced to be transmitted within 24 hours of the installation
magnet being removed. See Appendix D3 –General Information on “Forcing the CMU to Call.”
E2. Opening and closing the hatch is not triggering an alarm
E.2.1 If CMU was not installed in its final position within the 5-minute mounting period window
after removing the installation magnet, an open/close hatch will not trigger an alarm. Contact the
IONX Support Center (Appendix D) so a Customer Service Representative can correct the home
position of the CMU.
E.2.2 The CMU configuration is not set correctly. The CMU may not have been configured to report
open/close or tilt alarms inside facilities where authorized personal will typically be handling cars.
Contact the IONX Support Center (Appendix D) so a Customer Service Representative can check the
configuration of the CMU.
E3. Unit does not appear on IONXlive.net
E.3.1 If the asset does not appear on IONXlive.net it could be a limitation of the user’s login id.
Contact the IONX Support Center (Appendix D) so a Customer Service Representative can check the
permission level and adjust accordingly.
E.3.2 Initially the asset will be shown on IONXlive.net as the CMU serial number. When the CMU is
associated to an asset, the CMU serial number will be replaced by the car name.
E4. Power up message missing on IONXlive.net
If the CMU misses a power up message but has a recent message showing the current location,
then the CMU is OK to install.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 35 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Appendix F: Battery Replacement
Required Tools/Materials
Tool Name
(Part No)
Description
T-20 Torx driver with
torque capability of 2224 in/lbs
7.2V Power Supply or
Wall Wart
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 36 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Warning: Case can build up electrostatic charge. Clean the case by spraying with water. Do not
use cloth to clean the CMU. Remove CMU to area known to be non-hazardous.
Attention: Le boîtier peut accumuler une charge électrostatique. Nettoyez le boîtier en
pulvérisant de l'eau. N'utilisez pas de chiffon pour nettoyer le CMU. Retirer la CMU dans une
zone connue comme non dangereuse.
Warning: Do not open CMU in potentially explosive atmosphere.
ATTENTION: N'ouvrez pas la CMU dans une atmosphère potentiellement explosive.
F.1. Turn the CMUS unit over and remove the 4 T-20 Torx screws (IONX P/N 300842) that hold
the lid in place. See Figure F.1 below.
Figure F.1
T20 Screws
(300842)
F.2. Carefully turn the unit over, being sure to hold the lid in place, as you do so.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 37 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
F.3. Remove the lid, and set it aside. Inspect the enclosure and seal as directed by Appendix G. Figure F.2
below.
Figure F.2
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 38 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
F.4. Carefully lift the power cable from beside the main board and disconnect the battery. Figure F3.
Figure F.3
F.5. Remove the battery pack, and set aside.
WARNING: DO NOT PLACE USED HAZARDOUS BATTERY PACKS IN THE TRASH. THESE SHOULD BE
TAKEN TO A RECYLCING FACILITY THAT CAN PROPERLY DISPOSE OF THEM.
ATTENTION: NE PLACEZ PAS LES PACKS DE BATTERIE DANGEREUX UTILISES DANS LA POUBELLE. CES
DERNIERS DOIVENT ETRE UTILISES DANS UNE INSTALLATION DE RECYCLAGE QUI PEUT LES DISPOSER
CORRECTEMENT..
F.6. Connect a 7.2V power supply or wall wart to the power cable of the core module for a minimum of
5 minutes (preferably more) to pre-charge the core, and prevent errors once the new battery is
connected.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 39 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
F.7. Disconnect the power supply and select a new battery pack to install.
WARNING: BATTERY PACK 303382: USE ONLY ON IONX MODELS E4S and E5S.
WARNING: BATTERY PACK 303406: USE ONLY ON IONX MODELS E4X, E5X, and E6X.
ATTENTION: BATTERY PACK 303382: N'UTILISER QUE SUR LES MODÈLES IONX E4S et E5S.
ATTENTION: BATTERY PACK 303406: À UTILISER UNIQUEMENT SUR LES MODÈLES IONX E4X, E5X et
E6X.
From your email account (the one you have registered for the IONXLive web site with), start a new
email:



Enter ‘TARA@ionxlive.net’ in the ‘To’ recipient text box.
In the ‘Subject’ line of the email, enter the command for TARA in the following format:
B.CMUSerialNumber.OldBatterySerialNumber.NewBatterySerialNumber
When done, press ‘Send’. See Figure F.4 below.
Figure F.4
F.8. Within a few minutes, TARA will email back with either an error message or a message to say that
the command was successful. If successful, continue with Step 0 below. If an error message is received,
start over at Step 0 above. If the error message persists, contact IONX Customer Service at (800) 6218442.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 40 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
F.9. Install the new battery pack from Step F.7 above into battery chamber so that the connector is
facing main board, as shown in Figure F.5 below.
Figure F.5
F.10. Connect the battery to the core module.
F.11. Confirm device activation message was received using IONX E-series phone application.
F.12 Tuck the serial and power cables in the case.
F.13. Place the lid on the base enclosure as shown in Figure F.6 below.
WARNING: ENSURE NO CABLES ARE PINCHED BETWEEN THE LID AND BASE WHEN COVERING.
ATTENTION: ASSUREZ-VOUS QUE LES CÂBLES NE SONT PAS BRISÉS ENTRE LE COUVERCLE ET LA BASE LORS DE LA
COUVERTURE.
Battery Pack is
Under Here
Figure F.6
F.14. Press down on the lid around the edges to insure the O-Ring is fully seated.
F.15. Turn assembly over, and using the 4 #8-16 Plastite screws you removed in step 0 above, attach lid
to base enclosure.
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 41 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
WARNING: SLOWLY TURN THE SCREWS COUNTER-CLOCKWISE UNTIL YOU FEEL THEM
CLICK INTO THE EXISTING THREAD BEFORE TIGHTENING TO ENSURE HOLE IS NOT RETHREADED. FAILURE TO DO THIS WILL STRIP THE THREADS.
MISE EN GARDE: TOURNER LENTEMENT LES VIS DANS LE SENS ANTIHORAIRE JUSQU'À
CE QUE VOUS VOUS SENTEZ CLIQUER DANS LE FILET EXISTANT AVANT DE LE SERRER
POUR VOUS ASSURER QUE LE TROU NE SOIT PAS RETIRÉ. LE FAIT DE NE PAS FAIRE CECI
FERMERA LES FILS..
F.16. Tighten screws to a torque of 22.0-24.0 in/lbs.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 42 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Appendix G: Inspection of Equipment for
Return to Service
G.1. Enclosure base and lid shall be free of cracks.
G.2. Oring shall be free of cracks. If any part of the oring is removed, the oring gland must be cleaned to
be free of particulates.
G.3. Clean enclosure base top of oring surface with damp cloth.
G.4. Clean enclosure lid oring bump out with damp cloth.
G.5. Inspect power wires. Insulation shall be free of cracks.
G.6 Inspect NFC antenna and wire. Both shall be free of cracks.
G.7 Inspect circular Gore vent under enclosure base. Gore vent shall show no evidence of peeling,
puncture or cracking.
G.8 E6X version only: Inspect coax cable and antenna. Both shall be free of cracks.
G.9 Replace any parts that fail inspection.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 43 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Appendix H: Compliance Requirements
Intrinsic Safety Compliance
Conforms To
UL STDS 913, 60079-0, & 60079-11
Certified To
CSA STD C22.2 # 157, 60079-0, 60079-11, & 25
Electromagnetic Compliance
FCC ID 2ADEPCMUE5-A applies to CMU devices marked CMU-E5X and CMU-E5S.
FCC ID 2ADEPCMUE6-A applies to CMU devices marked CMU-E6X.
FCC ID R17HE910 applies to CMU devices marked CMU-E4S, CMU-E4X, CMU-E5S, CMU-E5X and
CMU-E6X.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Numéro de certification d'Industrie Canada IC: 12436A-CMUE5A s'applique aux appareils CMU
marqués CMU-E5X et CMU-E5S.
Numéro de certification d'Industrie Canada IC: 12436A-CMUE6A s'applique aux appareils CMU
marqués CMU-E6X.
Numéro de certification d'Industrie Canada IC: 5131A-HE910 s'applique aux appareils CMU
marqués CMU-E4S, CMU-E4X, CMU-E5S, CMU-E5X et CMU-E6X.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
Industry Canada Certification Number IC: 12436A-CMUE5A applies to CMU devices marked CMUE5X and CMU-E5S.
Industry Canada Certification Number IC: 12436A-CMUE6A applies to CMU devices marked CMUE6X.
Industry Canada Certification Number IC: 5131A-HE910 applies to CMU devices marked CMU-E4S,
CMU-E4X, CMU-E5S, CMU-E5X and CMU-E6X.
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 44 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
This device complies with Industry Canada’s license-exempt RSSs. Operation is subject
to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
[This space left blank intentionally]
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 45 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
Appendix I: Declaration of Conformity
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 46 of 47
IONX Support Center 1-800-621-8442, supportcenter@ionxlive.com
IONX LLC
515 S. Franklin St.
West Chester, PA 19382
www.ionxlive.com
484.653.2600
_____________________________________________________________________________________
303350 Installation Manual E-Series CMU
Confidential
Revision Date: 9-July-18
Revision: H
Process Owner: Engineering
Page 47 of 47

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 47
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Working T4 Install
Author                          : Heagerty, David
Creator                         : Microsoft® Word 2013
Create Date                     : 2018:07:10 11:34:27-04:00
Modify Date                     : 2018:07:10 11:34:27-04:00
Producer                        : Microsoft® Word 2013
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ADEPCMUE6-A

Navigation menu