IR TEC GC171910 Motion Detector User Manual

Ir Tec International Ltd Motion Detector

a href="https://usermanual.wiki/IR-TEC" itemprop="url"> IR TEC >

Contents

Manual DP 250

DUOGUARD PIR + Microwave Motion Detector DP-250 Installation Instructions R  INTERNAL VIEW ALARM TAMPER SW4C17C28BY1C31C4C33C32LED2LED3 LED11/3MAX.2/3MW.RANGEC10 C12 C8ALMMWPIRSWBSWACT35TerminalsMicrowave sensorPIR LED(Yellow)Microwave rangeadjustmentTamper switchRelayAlarm LED(Red)Infrared sensor(Don't touch!)Microwave LEC(Green)Jumper switchLocking boltCable access INSTALLATION HINTS The DUOGUARD may be either wall or corner mounted by applying different knockouts. The MB-95 or MB-99 mounting bracket can be applied for ceiling or wall mount. Corner mount is generally recommended for optimum detection. Do not install where the detector is in or facing direct/reflected sunlight, windows onto main roads (car head lights) or strong draughts / heaters. Ensure that there are not any obstructions (plants, screens, furniture etc.) in the field of view which may cause incorrect cover/ operation of the detector. Avoid locating the detector in areas which contain equipment that may change the environment temperature rapidly.  Locate the detector at least 1 meter away from any illumination to avoid possible interference to microwave sensor.  )Avoid running alarm wiring close to mains cables !!!  DETECTION PATTERN Model: DP-250 110°, 15 x 15m at 25°C      Top View  Side View              INSTALLATION & WIRING Installation 1.  Open the front cover by loosening the locking bolt at the bottom of the case.  2.  Remove the printed circuit board from the base of the unit, by bending the P.C.B clips gently upwards (handle printed circuit board with care).   3.  Punch out the required knockouts and mount the unit base to the wall, corner or bracket.  4.  Lead the cable through the access hole and then refit the printed circuit board.   5.  Connect the wires to the respective terminals according to the wiring instructions. 6.  Replace the front cover  after completing the wiring and carry out a through walk test. Wiring   +ALARM TAMPER-Tamper output (N.C loop)      Alarm output (N.C loop)Power input (9 ~ 16 VDC)  Min. 1mLight ) TAMPER terminals should be connected to the 24 hours N.C supervised  loop of control panel.
Download:
Mirror Download [FCC.gov]
Document ID709325
Application IDa7cWkkp2CTDIg8eelTMQwQ==
Document DescriptionManual DP 250
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.35kB (304327 bits)
Date Submitted2006-09-26 00:00:00
Date Available2006-09-26 00:00:00
Creation Date2006-07-27 11:36:36
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2006-09-22 09:33:33
Document Title中文目錄
Document CreatorAcrobat PDFMaker 6.0 for Word
Document Author: Jesse Huang
FCC ID Filing: NRIGC171910