Ibm Redpaper 520Q Users Manual GST, Inc. System P, P5, PSeries, RS/6000, I, I5, ISeries, AS/400, OpenPower And TotalStorage Experts.
P5 520 to the manual ee09489e-38c3-46c9-8954-fa05e2ec6bc0
2015-02-02
: Ibm Ibm-Redpaper-520Q-Users-Manual-431794 ibm-redpaper-520q-users-manual-431794 ibm pdf
Open the PDF directly: View PDF .
Page Count: 110
Download | |
Open PDF In Browser | View PDF |
Front cover IBM System p5 520 and 520Q Technical Overview and Introduction Finer system granulation using Micro-Partitioning technology to help lower TCO Support for versions of AIX 5L and Linux operating systems From Web servers to integrated cluster solutions Giuliano Anselmi Charlie Cler Carlo Costantini Bernard Filhol SahngShin Kim Gregor Linzmeier Ondrej Plachy ibm.com/redbooks Redpaper International Technical Support Organization IBM System p5 520 and 520Q Technical Overview and Introduction September 2006 Note: Before using this information and the product it supports, read the information in “Notices” on page vii. Second Edition (September 2006) This edition applies to IBM System p5 520 (product number 9131-52A), Linux, and IBM AIX 5L Version 5.3, product number 5765-G03. © Copyright International Business Machines Corporation 2006. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix The team that wrote this Redpaper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix Become a published author . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .x Comments welcome. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .x Chapter 1. General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 System specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2 Physical package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2.1 Deskside model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2.2 Rack-mount model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3 Minimum and optional features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.3.1 Processor features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.3.2 Memory features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.3.3 Disk and media features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.3.4 USB diskette drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1.3.5 I/O drawers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1.3.6 Hardware Management Console models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.4 Express Product Offerings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.4.1 Express Product Offerings requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.4.2 Configurator starting points for Express Product Offerings. . . . . . . . . . . . . . . . . . 11 1.5 System racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 1.5.1 IBM 7014 Model T00 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 1.5.2 IBM 7014 Model T42 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 1.5.3 IBM 7014 Model S11 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 1.5.4 IBM 7014 Model S25 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 1.5.5 S11 rack and S25 rack considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 1.5.6 The ac power distribution unit and rack content . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1.5.7 Rack-mounting rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 1.5.8 Additional options for the rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 1.5.9 OEM rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Chapter 2. Architecture and technical overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 The POWER5+ processor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Processor and cache . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.1 POWER5+ single-core module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.2 The p5-520 POWER5+ dual-core module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.3 The p5-520Q quad-core module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.4 Available processor speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 Memory subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.1 Memory placement rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.2 OEM memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.3 Memory throughput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 I/O buses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 Internal I/O subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6 64-bit and 32-bit adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.1 LAN adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . © Copyright IBM Corp. 2006. All rights reserved. 25 26 27 27 28 29 30 30 31 32 32 33 34 35 35 iii iv 2.6.2 SCSI adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.3 Integrated RAID options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.4 iSCSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.5 Fibre Channel adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.6 Graphic accelerators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.7 InfiniBand Host Channel adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.8 Asynchronous PCI-X adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.9 PCI-X Cryptographic Coprocessor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.10 Additional support for PCI-X adapters you own . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.11 Internal system ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.12 Ethernet ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7 Internal storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7.1 Internal media devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7.2 Internal hot-swappable SCSI disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8 External I/O subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8.1 I/O drawers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8.2 7311 I/O drawer RIO-2 cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8.3 7311 Model D20 I/O drawer SPCN cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9 External disk subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9.1 IBM TotalStorage EXP24 Expandable Storage . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9.2 IBM System Storage N3000 and N5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9.3 IBM TotalStorage DS4000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9.4 IBM TotalStorage DS6000 and DS8000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10 Logical partitioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10.1 Dynamic logical partitioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11 Virtualization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11.1 POWER Hypervisor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12 Advanced POWER Virtualization feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12.1 Micro-Partitioning technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12.2 Logical, virtual, and physical processor mapping . . . . . . . . . . . . . . . . . . . . . . . . 2.12.3 Virtual I/O Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12.4 Partition Load Manager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12.5 Integrated Virtualization Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13 Hardware Management Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13.1 High availability using the HMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13.2 IBM System Planning Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.14 Operating system support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.14.1 AIX 5L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.14.2 Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.1 Touch point colors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.2 Securing a rack-mounted system into a rack . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.3 Placing a rack-mounted system into a rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.4 Cable-management arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.5 Operator control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.6 System firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.7 Service processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.8 Hardware management user interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 36 36 38 39 39 39 40 40 40 41 41 41 41 43 43 44 45 46 46 47 47 47 48 48 48 49 51 51 52 54 57 57 60 62 62 64 64 65 66 67 67 67 68 69 70 73 73 Chapter 3. RAS and manageability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Reliability, availability, and serviceability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.1 Fault avoidance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.2 First-failure data capture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 78 78 78 IBM System p5 520 and 520Q Technical Overview and Introduction 3.1.3 Permanent monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.4 Self-healing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.5 N+1 redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.6 Fault masking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.7 Resource deallocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.8 Serviceability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Manageability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.1 Service processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.2 Partition diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.3 Service Agent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.4 IBM System p5 firmware maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 Cluster solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 80 81 81 81 82 83 83 84 85 87 88 Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IBM Redbooks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Other publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Online resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How to get IBM Redbooks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Help from IBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 91 91 92 93 93 Contents v vi IBM System p5 520 and 520Q Technical Overview and Introduction Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing, IBM Corporation, North Castle Drive Armonk, NY 10504-1785 U.S.A. The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. COPYRIGHT LICENSE: This information contains sample application programs in source language, which illustrates programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. You may copy, modify, and distribute these sample programs in any form without payment to IBM for the purposes of developing, using, marketing, or distributing application programs conforming to IBM's application programming interfaces. © Copyright IBM Corp. 2006. All rights reserved. vii Trademarks The following terms are trademarks of the International Business Machines Corporation in the United States, other countries, or both: Eserver® Redbooks (logo) pSeries® AIX 5L™ AIX® Chipkill™ DS4000™ DS6000™ DS8000™ FICON® ™ HACMP™ IBM® Micro-Partitioning™ OpenPower™ PowerPC® POWER™ POWER Hypervisor™ POWER4™ POWER5™ POWER5+™ PTX® Redbooks™ RS/6000® Service Director™ System p™ System p5™ System Storage™ TotalStorage® Virtualization Engine™ 1350™ The following terms are trademarks of other companies: Internet Explorer, Microsoft, Windows, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. UNIX is a registered trademark of The Open Group in the United States and other countries. Linux is a trademark of Liux Torvalds in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. viii IBM System p5 520 and 520Q Technical Overview and Introduction Preface This IBM Redpaper is a comprehensive guide that covers the IBM® System p5™ 520 and 520Q UNIX® servers. It introduces major hardware offerings and discusses their prominent functions. Professionals who want to acquire a better understanding of IBM System p™ products should read this document. The intended audience includes: Clients Marketing representatives Technical support professionals IBM Business Partners Independent software vendors This document expands the current set of IBM System p documentation and provides a desktop reference that offers a detailed technical description of the p5-520 and the p5-520Q system. This publication does not replace the latest IBM System p marketing materials and tools. It is intended as an additional source of information that you can use, together with existing sources, to enhance your knowledge of IBM server solutions. The team that wrote this Redpaper This Redpaper was produced by a team of specialists from around the world working at the International Technical Support Organization (ITSO), Austin Center. Giuliano Anselmi is a certified pSeries® Presales Technical Support Specialist who works in the Field Technical Sales Support group based in Rome, Italy. For seven years, he was an IBM Sserver pSeries Systems Product Engineer, supporting the Web Server Sales Organization in EMEA, IBM Sales, IBM Business Partners, Technical Support Organizations, and IBM Dublin eServer Manufacturing. Giuliano has worked for IBM for 14 years, devoting himself to RS/6000® and pSeries systems with his in-depth knowledge of the related hardware and solutions. Charlie Cler is a Certified IT Specialist for IBM and has over 21 years of experience with IBM. He currently works in the United States as a presales Systems Architect representing IBM Systems and Technology Group product offerings. He has been working with IBM System p servers for over 16 years. Carlo Costantini is a Certified IT Specialist for IBM and has over 28 years of experience with IBM and IBM Business Partners. He currently works in Italy Presales Field Technical Sales Support for IBM Sales Representatives and IBM Business Partners for all pSeries and IBM System p5 systems offerings. He has broad marketing experience. He is a certified specialist for pSeries and IBM System p servers. Bernard Filhol is a UNIX Server Customer Satisfaction Resolution Team Leader for NEE and SWE IOTs in Montpellier, France. He has more than 25 years of experience in mainframes and five years of experience in pSeries Customer Satisfaction. He holds a degree in Electronics from Montpellier University Institute of Technology. His areas of © Copyright IBM Corp. 2006. All rights reserved. ix expertise include Mainframe Channel Subsystem, FICON®, and pSeries RAS. He has written extensively on FICON. SahngShin Kim is a sales specialist of STG infra-solution sales team in Seoul, Korea. For three years, he was a sales specialist of IBM eServer pSeries, for two years of grid computing, and for one year for infra-solutions. SahngShin has worked for IBM for six years, devoting himself to RS/6000 and pSeries systems and STG server products and as an architect for these products. Gregor Linzmeier is an IBM Advisory IT Specialist for RS/6000 and pSeries workstation and entry servers as part of the Systems and Technology Group in Mainz, Germany, supporting IBM sales, IBM Business Partners, and clients with pre-sales consultation and implementation of client/server environments. He has worked for more than 15 years as an infrastructure specialist for RT, RS/6000, and AIX® in large CATIA client/server projects. Ondrej Plachy is an IT specialist in IBM Czech Republic responsible for project design, implementation, and support of large scale computer systems. He has 11 years of experience in the UNIX field. He holds the Ing. academic degree in Computer Science from Czech Technical University (CVUT), Prague. He has worked at Supercomputing Centre of Czech Technical University for four years and currently works for IBM (seven years) in the AIX 5L™ support team. The project that produced this document was managed by: Scott Vetter IBM U.S. Thanks to the following people for their contributions to this project: Larry Amy, Baba Arimilli, Ron Arroyo, Joergen Berg, Terry Brennan, Erin Burke, Mark Dewalt, Bob Foster, Ron Gonzalez, Dan Henderson, David A. Hepkin, Tenley Jackson, Hal Jennings, Carolyn Jones, Brian J King, Bill Mihaltse, Thoi Nguyen, Ken Rozendal, Craig Shempert, Doug Szerdi, and Dave Willoughby IBM Become a published author Join us for a two- to six-week residency program! Help write an IBM Redbook dealing with specific products or solutions, while getting hands-on experience with leading-edge technologies. You'll team with IBM technical professionals, Business Partners, or clients. Your efforts will help increase product acceptance and client satisfaction. As a bonus, you'll develop a network of contacts in IBM development labs, and increase your productivity and marketability. Find out more about the residency program, browse the residency index, and apply online at: ibm.com/redbooks/residencies.html Comments welcome Your comments are important to us! We want our papers to be as helpful as possible. Send us your comments about this Redpaper or other Redbooks™ in one of the following ways: x IBM System p5 520 and 520Q Technical Overview and Introduction Use the online Contact us review redbook form found at: ibm.com/redbooks Send your comments in an e-mail to: redbook@us.ibm.com Mail your comments to: IBM Corporation, International Technical Support Organization Dept. HYTD Mail Station P099 2455 South Road Poughkeepsie, NY 12601-5400 Preface xi xii IBM System p5 520 and 520Q Technical Overview and Introduction 1 Chapter 1. General description The IBM System p5 520 and IBM System p5 520Q rack-mount and deskside servers (9131-52A) give you new tools for managing on demand business, greater application flexibility, and innovative technology in 1-core, 2-core, and 4-core configurations — all designed to help you capitalize on the on demand business revolution. To simplify naming, both products are referred to as p5-520 or p5-520Q. The p5-520 and p5-520Q have POWER5+™ processors which provide performance and reliability advances (or enhancements) over the POWER5™ architecture that it replaces. Chief among the enhancements is 90 nm processor fabrication technology. The p5-520 processor is packaged as a 1-core single-core module running at 1.65 GHz with no L3 cache or as a 1-core single-core module running at 2.1 GHz with 36 MB of L3 cache or a 2-core dual-core module running at 1.65 or 1.9 or 2.1 GHz with 36 MB of L3. The p5-520Q offers the same features but comes with a 4-core POWER5+ quad-core module running at 1.5 or 1.65 GHz with two 36 MB of L3 caches. When you purchase a p5-520 or p5-520Q Express Product Offering that is only available on an initial order request, you might qualify for processor activation at no extra charge. The number of processors, total memory, quantity and size of disk, and the presence of a media device are the only features that determine if you are entitled to a processor entitlement at no additional charge. Contact your marketing representative regarding the feature for Express Product Offering or volume offering. The p5-520 and p5-520Q server have a base of 1 GB of DDR2 memory that can be expanded to 32 GB, designed for performance and exploitation of 64-bit addressing as used in large database applications. The p5-520 and p5-520Q include four front-accessible, hot-swap capable disk bays in a minimum configuration with an additional four hot-swap capable disk bays as an optional feature. The eight disk bays can accommodate up to 2.4 TB of disk storage using the 300 GB Ultra320 SCSI disk drives. Other features included in the p5-520 and p5-520Q are six hot-plug PCI-X slots with Enhanced Error Handling (EEH), integrated service processor, integrated 10/100/1000 Mbps two-port Ethernet, two system, two USB, and two Hardware Management Console (HMC) ports, integrated dual-channel Ultra320 SCSI controller, hot-swappable power and cooling, and optional redundant power. © Copyright IBM Corp. 2006. All rights reserved. 1 Three non-hot-swappable media bays are used to accommodate additional devices. Two media bays only accept slim-line media devices, such as DVD-ROM or DVD-RAM drives, and one half-height bay is used for a tape drive. The rack-mount model also has I/O extension capability using the RIO-2 bus that allows attachment of the 7311 Model D20 I/O drawers. For partitioning, we recommend an HMC. Dynamic LPAR is supported on the p5-520 and p5-520Q servers, allowing up to two logical partitions. In addition, the optional Advanced POWER™ Virtualization feature supports up to 40 micro-partitions using Micro-Partitioning™ technology. The Integrated Virtualization Manager provides partition management in settings where an HMC is unavailable or not desired. Additional reliability and availability features include redundant hot-swappable cooling fans and redundant power supplies. Along with these components, the p5-520 and p5-520Q are designed to provide an extensive set of reliability, availability, and serviceability (RAS) features that include a dual service processor, fault isolation, recovery from errors without stopping the system, avoidance of recurring failures, and predictive failure analysis. The p5-520 and p5-520Q are backed by a three-year limited warranty. Check with your IBM representative for particular warranty availability in your region. 2 IBM System p5 520 and 520Q Technical Overview and Introduction 1.1 System specifications Table 1-1 lists the general system specifications of the p5-520 and p5-520Q systems. Table 1-1 IBM System p5 520 and IBM System p5 520Q specifications Description Range Operating temperature 5 to 35 degrees Celsius (41 to 95 F) Relative humidity 8% to 80% Operating voltage 100 to 127 or 200 to 240 V ac (auto-ranging) Operating frequency 47/63 Hz Maximum power consumption 750 watts maximum Maximum thermal output 2560 BTU/hour (maximum) 1.2 Physical package This section discusses the major physical attributes of the p5-520 and p5-520Q systems in rack-mounted and deskside versions that are selectable through a feature code. 1.2.1 Deskside model The p5-520 and p5-520Q can be configured as deskside models. Table 1-2 lists the physical attributes1 and Figure 1-1 on page 4 shows the system. Table 1-2 Physical attributes of the deskside model Dimensiona Deskside (FC 7919) Height 533 mm (21.0 in.) Width 201 mm (7.9 in.) Depth (without rear cover; FC 6587) 630.0 mm (23.0 in.) Depth (with rear cover; FC 6587) 706.0 mm (27.8 in.) Weight Weight 43 kg (95 lb.) Shipping weight 50 kg (110 lb.) a. For a specific region, such as China, check specifications for specific dimensions. 1 One Electronic Industries Association Unit (1U) is 44.45 mm (1.75 in.). Chapter 1. General description 3 Figure 1-1 The deskside model (FC 7184) and acoustic cover (right FC 7185) The p5-520 or p5-520Q, when configured as a deskside server, is ideal for environments that require local access to the machine, such as applications that require a native graphics display. To order a system as a deskside version, FC 7184 or FC 7185 is required. FC 7185 is designed for quiet operation in office environments. The system is designed to be set up by the client and, in most cases, does not require the use of any tools. The system includes full setup instructions. The GXT135P 2D graphics accelerator with analog and digital interfaces (FC 1980) is available and is supported for SMS, firmware menus, and other low-level functions, as well as when AIX 5L or Linux® starts the X11-based graphical user interface. You can use graphical AIX 5L system tools for configuration management if the adapter is connected to the primary console, such as the IBM 15-inch, 17-inch, 19-inch, or 20-inch TFT Color Monitor (FC 3641, FC 3645, FC 3644, and FC 3643). 4 IBM System p5 520 and 520Q Technical Overview and Introduction 1.2.2 Rack-mount model The IBM System p5 520 or IBM System p5 520Q can be configured as a 4U rack-mount model with the selected feature code. Table 1-3 lists the physical attributes and Figure 1-2 shows the system. Table 1-3 Physical attributes of the rack-mount model Dimensiona Rack (FC 7918) Height 178 mm (7.0 in.) Width 437 mm (17.2 in.) Depth 584 mm (23.0 in.) Weight Weight 43.0 kg (95 lb.) Shipping weight 53.0 kg (117 lb.) a. For a specific region, such as China, check specifications for specific dimensions. Figure 1-2 IBM System p5 520 and IBM System p5 520Q rack-type model (FC 7160) The p5-520 or p5-520Q, when configured as a 4U rack-mounted server, is intended to be installed in a 19-inch rack, thereby enabling efficient use of computer room floor space. If the IBM 7014 T42 rack is used to mount the server, it is possible to place up to 10 systems in an area of 644 mm (25.5 in.) x 1147 mm (45.2 in.). To order a p5-520 or p5-520Q system as a rack-mounted version, FC 7190 must be selected. In addition to the rack-mounted version, the server can be installed in either IBM or OEM racks. Therefore, you are required to select one of the following features: IBM Rack-mount Drawer Rail Kit (FC 7160) OEM Rack-mount Drawer Rail Kit (FC 7161) Included with the rack-mounted server packaging are all of the components and instructions necessary to enable installation in a 19-inch rack using suitable tools. The GXT135P 2D graphics accelerator with analog and digital interfaces (FC 1980) is available and is supported for SMS, firmware menus, and other low-level functions, as well as when AIX 5L or Linux starts the X11-based graphical user interface. You can use graphical Chapter 1. General description 5 AIX 5L system tools for configuration management if the adapter is connected to a common maintenance console, such as the 7316-TF3 rack-mounted flat-panel display. 1.3 Minimum and optional features The systems are based on a flexible, modular design based on POWER5+ processors. The server is available in 1-core, 2-core, and 4-core configurations that feature the following: 1.65 (SCM and DCM), 1.9 or 2.1 GHz (DCM), and 1.5 or 1.65 GHz (QCM) POWER5+ processors. From 1 GB to 32 GB of total system memory capacity using 533 MHz DDR2 DIMM technology. Four SCSI disk drives in a minimum configuration, eight SCSI disk drives with an optional second 4-pack enclosure for a total internal storage capacity of 2.4 TB using 300 GB disk drives. Six PCI-X slots (one 266 MHz 64-bit PCIX-2, three 133 MHz 64-bit PCI-X, two 66 MHz 32-bit PCI-X). All slots support Enhanced Error Handling (EEH). Two slim-line media bays for optional storage devices. One half-high bay for an optional tape device. The p5-520 and p5-520Q, including the service processor that is described in 3.2.1, “Service processor” on page 83, support the following native ports: Two 10/100/1000 Ethernet ports on a single controller Two system ports Two USB 2.0 ports on a single controller Optionally, an external USB diskette drive 1.44 (FC 2591) is available. Two HMC ports Optional GX+ Bus to RIO-2 adapter card (FC 2888) Two SPCN ports In addition, the p5-520 and p5-520Q feature one internal Ultra320 SCSI dual channel controller, redundant hot-swap power supply (optional), and cooling fans. The system supports 32-bit and 64-bit applications and requires specific levels of AIX 5L and Linux operating systems. For more information, see 2.14, “Operating system support” on page 64. 1.3.1 Processor features The p5-520 features one or two POWER5+ processors, each with one or two cores running at 1.65 GHz, 1.9 GHz, or 2.1 GHz, or the p5-520Q with four cores running at 1.5 GHz or 1.65 GHz. The processors are installed on either single-core modules (SCM), dual-core modules (DCM), or quad-core modules (QCM). The POWER5+ processor modules are mounted directly to the system planar. Table 1-4 on page 7 lists the available processor features. 6 IBM System p5 520 and 520Q Technical Overview and Introduction Table 1-4 Processor feature codes Feature code Description 8321 1-core 1.65 GHz POWER5+ Processor Card, no L3 Cache 8323 2-core 1.65 GHz POWER5+ Processor Card, 36 MB L3 Cache 8330 2-core 1.9 GHz POWER5+ Processor Card, 36 MB L3 Cache 8315 1-core 2.1 GHz POWER5+ Processor Card, 36 MB L3 Cache 8316 2-core 2.1 GHz POWER5+ Processor Card, 36 MB L3 Cache 8333 4-core 1.5 GHz POWER5+ Processor Card, 2 x 36 MB L3 Cache 8314 4-core 1.65 GHz POWER5+ Processor Card, 2 x 36 MB L3 Cache Note: When configuring p5-520 and p5-520Q systems, remember that the processor modules are mounted directly on the system planar and cannot be upgraded. 1.3.2 Memory features The minimum memory requirement for the p5-520 and p5-520Q servers is 1 GB, and the maximum capacity is 32 GB using 533 MHz DDR2 technology. The planar of each system has eight sockets for memory DIMMs. Table 1-5 lists the available memory features. Table 1-5 Memory feature codes Feature code Description 1930 1 GB (2 x 512 MB) DIMMs, 276-pin DDR2, 533 MHz SDRAM 1931 2 GB (2 x 1 GB) DIMMs, 276-pin DDR2, 533 MHz SDRAM 1932 4 GB (2 x 2 GB) DIMMs, 276-pin DDR2, 533 MHz SDRAM 1934 8 GB (2 x 4 GB) DIMMs, 276-pin DDR2, 533 MHz SDRAM Note that an amount of memory is always in use by the Hypervisor, even when the machine is not partitioned. You can use the System Planning Tool to calculate the amount of available memory for an operating system based on machine configuration as follows: http://www.ibm.com/servers/eserver/iseries/lpar/systemdesign.html 1.3.3 Disk and media features The minimum configuration includes a 4-pack disk drive enclosure. A second 4-pack disk drive enclosure can be installed by ordering FC 6574 or FC 6594, so that the maximum internal storage capacity can reach 2.4 TB (using the disk drive features available at the time of writing). The p5-520 and p5-520Q feature up to eight disk drive bays, two slim-line media device bays, and one half-height media bay. The minimum configuration requires at least one disk drive. Table 1-6 shows the disk drive feature codes that each bay can contain. Chapter 1. General description 7 Table 1-6 Hot-swappable disk drive options Feature code Description 1968 73.4 GB ULTRA320 10 K rpm SCSI hot-swappable disk drive 1969 146.8 GB ULTRA320 10 K rpm SCSI hot-swappable disk drive 1970 36.4 GB ULTRA320 15 K rpm SCSI hot-swappable disk drive 1971 73.4 GB ULTRA320 15 K rpm SCSI hot-swappable disk drive 1972 146.8 GB ULTRA320 15 K rpm SCSI hot-swappable disk drive 1973 300 GB ULTRA320 10 K rpm SCSI hot-swappable disk drive You can install any combination of the following DVD-ROM and DVD-RAM drives in the two slim-line bays: DVD-RAM drive, FC 1993 DVD-ROM drive, FC 1994 A logical partition running a supported release of Linux requires a DVD-ROM drive or DVD-RAM drive to provide a way to run the diagnostics CD for hardware diagnostics. Concurrent diagnostics, as provided by the AIX 5L diag command, are not available on the Linux operating system at the time of writing. You can install supplementary devices in the half-height media bay, such as: Internal 4 mm 36/72 GB LVD tape drive, FC 1991 IBM 80/160 GB internal tape drive VXA, FC 1992 IBM 160/320 GB internal tape drive with VXA-3 technology, FC 1892 IBM 200/400 GB LTO2 tape drive, FC 1997 DVD devices installed in the slim-line bays must be assigned as a group to a single LPAR on a partitioned system. A dual-channel RAID enablement daughter card is also available (FC 1907). 1.3.4 USB diskette drive The externally attached USB diskette drive provides storage capacity up to 1.44 MB (FC 2591) on high-density (2HD) floppy disks and 720 KB on a double density floppy disk. It includes a 350 mm (13.7 in.) cable with standard USB connector. This super slim-line and lightweight USB V2-attached diskette drive takes its power requirements from the USB port. The drive can be attached to the integrated USB ports or to a USB adapter (FC 2738). A maximum of one USB diskette drive is supported per integrated controller/adapter. The same controller can share a USB mouse and keyboard. 1.3.5 I/O drawers The p5-520 and p5-520Q have six internal PCI-X slots — three long slots and three short slots. If you need more PCI-X slots to extend the number of LPARs and partitions, you can connect up to four 7311 Model D20 drawers to the optional RIO-2 ports (FC 2888) that are provided on the rear of the system in a minimum configuration. The 7311 Model D20 I/O drawer is a 4U full-size drawer, which must be mounted in a rack. It features seven hot-pluggable PCI-X slots and, optionally, up to 12 hot-swappable disks arranged in two 6-packs. Redundant, concurrently maintainable power and cooling is an optional feature (FC 6268). The 7311 Model D20 I/O drawer offers a modular growth path for a system with increasing I/O requirements. When a p5-520 or p5-520Q is fully configured with 8 IBM System p5 520 and 520Q Technical Overview and Introduction four attached 7311 Model D20 drawers, the combined system supports up to 34 PCI-X adapters (in a maximum configuration, remote I/O expansion cards are required) and 56 hot-swappable SCSI disks, for a total internal capacity of 16.8 TB using 300 GB disks. PCI-X and PCI cards are inserted from the top of the I/O drawer down into the slot from the drawer’s front service position. The installed adapters are protected by plastic separators, which are designed to prevent grounding and damage when adding or removing adapters. The drawer has the following attributes: 4U rack-mount enclosure assembly Seven PCI-X slots 3.3 volt, keyed, 133 MHz hot-pluggable Two 6-pack hot-swappable SCSI bays (optional) Redundant hot-swap power (optional) Two RIO-2 ports and two SPCN ports Note: A 7311 Model D20 I/O drawer initial order or an existing 7311 Model D20 I/O drawer that is migrated from another pSeries system must have the RIO-2 ports available (FC 6417). The I/O drawer has the following physical characteristics: Width: 482 mm (19.0 in.) Depth: 610 mm (24.0 in.) Height: 178 mm (7.0 in.) Weight: 45.9 kg (101 lb.) Figure 1-3 shows the different views of the 7311-D20 I/O drawer. Adapters Service Access I/O Drawer Front Rear Operator panel Power supply 2 Power supply 1 1 8 9 A B C D 8 9 A B SCSI disk locations and IDs C RIO ports 2 3 4 5 6 7 D SPCN ports PCI-X slots Reserved ports Rack indicator Figure 1-3 7311-D20 I/O drawer views Chapter 1. General description 9 Note: The 7311 Model D20 I/O drawer is designed to be installed by an IBM service representative. Only the 7311 Model D20 I/O drawer is supported on a p5-520 or p5-520Q system. 1.3.6 Hardware Management Console models A p5-520 or p5-520Q can be either HMC-managed or non-HMC-managed. In HMC-managed mode, an HMC is required as a dedicated workstation that allows you to configure and manage partitions. The HMC provides a set of functions to manage the system LPARs, dynamic LPAR operations, virtual features, Capacity on Demand, inventory and microcode management, and remote power control functions. These functions also include the handling of the partition profiles that define the processor, memory, and I/O resources allocated to an individual partition. For detailed information about the HMC, see 2.13, “Hardware Management Console” on page 60. Note: Non-HMC-managed modes are full system partition modes, where only one partition contains all system resources that exist on the system. For more information about using the Integrated Virtualization Manager (IVM), see 2.12.5, “Integrated Virtualization Manager” on page 57. Table 1-7 lists the HMC options for POWER5 processor-based systems that are available at the time of writing. You can also use existing HMC models. Table 1-7 Supported HMC models Type-model Description 7310-C05 IBM 7310 Model C05 Deskside Hardware Management Console 7310-CR3 IBM 7310 Model CR3 Rack-Mount Hardware Management Console Systems require Ethernet connectivity between HMC and one of the Ethernet ports of the service processor. Ensure that sufficient HMC Ethernet ports are available to enable public and private networks if you need both. The 7310 Model C05 is a deskside model with one native 10/100/1000 Ethernet port. It can be extended with two additional two-port 10/100/1000 Gb adapters. The 7310 Model CR3 is a 1U, 19-inch rack mountable drawer that has two native Ethernet ports and can be extended with one additional two-port 10/100/1000 Gb adapter. In HMC-managed installations with very high demand for high availability, you should consider deployment of two HMCs. The service processor allows for connection of two HMCs, and there is no need for special handling of a dual HMC environment. HMCs provide a locking mechanism so that only one HMC has write access to the service processor at a time. When an HMC is connected to the system, the integrated system ports are disabled. To support a non-Ethernet HACMP™ heartbeat, you need to provide an asynchronous adapter (FC 5723 or FC 2943). Note: It is not possible to connect POWER4™ with POWER5 or POWER5+ processor-based systems simultaneously to the same HMC. However, it is possible to connect POWER5 and POWER5+ processor-based systems together to the same HMC. 10 IBM System p5 520 and 520Q Technical Overview and Introduction 1.4 Express Product Offerings The Express Product Offerings provide a convenient way to order any of several configurations that are designed to meet typical client requirements. Special reduced pricing is available when a system order satisfies specific configuration requirements for memory, disk drives, and processors. 1.4.1 Express Product Offerings requirements When you order an Express Product Offering, the configurator offers a choice of starting points onto which you can add. You can configure systems with one or two processor cards and two or four processor activations. With the purchase of an Express Product Offering, for each paid processor activation, you are entitled to one processor activation at no additional charge, if the following requirements are met: The system must have at least two disk drives of at least 73.4 GB each. There must be at least 2 GB of memory installed for each active processor. If you order a p5-520 server Express Product Offering as defined here, you might qualify for a processor activation at no extra charge. The number of processors, total memory, quantity and size of disk, and presence of a media device are the only features that determine if a client is entitled to a processor entitlement at no additional charge. When you purchase an Express Product Offering, you are entitled to a lower priced AIX 5L or Linux operating system license, or you can choose to purchase the system with no operating system. The lower priced AIX 5L or Linux operating system is processed via a feature number on AIX 5L and either Red Hat or SUSE Linux. You can choose either the lower priced AIX 5L or Linux subscription, but not both. If you choose AIX 5L for your lower priced operating system, you can also order Linux but will purchase your Linux subscription at full price versus the reduced price. The same is true if you choose a Linux subscription as your lower priced operating system. Systems with a reduced price AIX 5L offering are the IBM System p5 Express Product Offering, AIX 5L edition. Systems with a lower priced Linux operating system are referred to as the IBM System p5 Express Product Offering, OpenPower™ edition. In the case of Linux, only the first subscription purchased is lower priced. So, for example, additional licenses purchased for Red Hat to run in multiple partitions will be at full price. You can make changes to the standard features as needed and still qualify for processor entitlements at no additional charge and a reduced price AIX 5L or Linux operating system license. If the system was initially ordered as an Express Product Offering, the system can be expanded at a later time using Express Product Offering pricing, when additional processors and activations along with the required memory are ordered on the same hardware upgrade order. The upgraded p5-520Q configuration must satisfy the Express Product Offering requirements for disk drives, memory, and processors. However, if the selection of total memory or disk drives is smaller than the total defined as the minimums, it disqualifies the order as an Express Product Offering. 1.4.2 Configurator starting points for Express Product Offerings All Express Product Offerings have a set of standard features for the rack-mounted or deskside versions as listed in Table 1-8 on page 12. Chapter 1. General description 11 Table 1-8 Express Product Offering standard set of feature codes Feature code description Rack-mounted feature codes Deskside feature code System bezel and hardware 7190 7916 x 1 Rack-mount rail kit 7160 x 1 n/a 850 Watt power supply 5159 x 1 5159x 1 IDE DVD-ROM 1994 x 1 1994 x 1 Media backplane 7877 x 1 7877 x 1 4-pack disk drive enclosure 6574 x 1 6574 x 1 73.4 GB 10 k disk drives 1968 x 2 1968 x 2 A specific Express Product Offering ID or specific offering feature code is used to select the processor type and quantity, and the associated memory feature code and quantity, on top of the standard set. Table 1-9 and Table 1-10 provide these configuration differences. Table 1-9 Express Product Offering features - SCM and DCM configurations Description 1.65 GHz 1.9 GHz 2.1 GHz Configuration 1-core 2-core 2-core 1-core 2-core Processor cards 8321 x 1 8323 x 1 8330 x 1 8315 x 1 8316 x 1 Processor activations n/a 7309 x 1 7320 x 1 n/a 7271 x 1 Zero-priced express activations 8418 x 1 8419 x 1 8410 x 1 8480 x 1 8481 x 1 Total active processors 1 2 1 1 2 Minimum memory 1 GB 2 GB 2 GB 1 GB 2 GB Table 1-10 Express Product Offering features - QCM configurations Description 1.5 GHz 1.65 GHz Configuration 4-core 4-core Processor cards 8333 x 1 8314 Processor activations 7337 x 2 7269 Zero-priced express activations 8421 x 2 8479 Total active processors 4 4 Minimum memory 4 GB 4 GB 1.5 System racks The IBM 7014 Model S11, S25, T00, and T42 Racks are 19-inch racks for general use with IBM System p and OpenPower Edition rack-mount servers. The racks provide increased capacity, greater flexibility, and improved floor space utilization. 12 IBM System p5 520 and 520Q Technical Overview and Introduction If a server is to be installed in a non-IBM rack or cabinet, you must ensure that the rack conforms to the EIA2 standard EIA-310-D (see 1.5.9, “OEM rack” on page 21). Note: It is the client’s responsibility to ensure that the installation of the drawer in the preferred rack or cabinet results in a configuration that is stable, serviceable, safe, and compatible with the drawer requirements for power, cooling, cable management, weight, and rail security. 1.5.1 IBM 7014 Model T00 rack The 1.8-meter (71-inch) Model T00 is compatible with past and present IBM System p systems. It is a 19-inch rack and is designed for use in all situations that have previously used the earlier rack models R00 and S00. The T00 rack has the following features: 36 EIA units (36U) of usable space. Optional removable side panels. Optional highly perforated front door. Optional side-to-side mounting hardware for joining multiple racks. Standard business black or optional white color in OEM format. Increased power distribution and weight capacity. Optional reinforced (ruggedized) rack feature (FC 6080) provides added earthquake protection with modular rear brace, concrete floor bolt-down hardware, and bolt-in steel front filler panels. Support for both ac and dc configurations. The dc rack height is increased to 1926 mm (75.8 in.) if a power distribution panel is fixed to the top of the rack. Up to four power distribution units (PDUs) can be mounted in the PDU bays (see Figure 1-4 on page 17); additional PDUs can fit inside the rack. See 1.5.6, “The ac power distribution unit and rack content” on page 16. Weights: – T00 base empty rack: 244 kg (535 pounds) – T00 full rack: 816 kg (1795 pounds) 1.5.2 IBM 7014 Model T42 rack The 2.0-meter (79.3-inch) Model T42 addresses the client requirement for a tall enclosure to house the maximum amount of equipment in the smallest possible floor space. The features that differ in the Model T42 rack from the Model T00 include: 42 EIA units (42U) of usable space (6U of additional space). The Model T42 supports ac only. Weights: – T42 base empty rack: 261 kg (575 lb.) – T42 full rack: 930 kg (2045 lb.) 2 Electronic Industries Alliance (EIA). Accredited by American National Standards Institute (ANSI), EIA provides a forum for industry to develop standards and publications throughout the electronics and high-tech industries. Chapter 1. General description 13 Optional Rear Door Heat eXchanger (FC 6858) Improved cooling from the heat exchanger enables the client to more densely populate individual racks freeing valuable floor space without the need to purchase additional air conditioning units. The Rear Door Heat eXchanger features: Water-cooled heat exchanger door designed to dissipate heat generated from the back of computer systems before it enters the room An easy-to-mount rear door design that attaches to client-supplied water, using industry standard fittings and couplings Up to 15 KW (approximately 50,000 BTUs/hr.) of heat removed from air exiting the back of a fully populated rack One year, limited warranty Physical specifications The physical specifications are: Approximate height: 1945.5 mm (76.6 in.) Approximate width: 635.8 mm (25.03 in.) Approximate depth: 141.0 mm (5.55 in.) Approximate weight: 31.9 kg (70.0 lb.) Client responsibilities The client responsibilities are: Secondary water loop (to the building chilled water) Pump solution (for secondary loop) Delivery solution (hoses and piping) Connections: standard 3/4-inch internal threads 1.5.3 IBM 7014 Model S11 rack The Model S11 rack satisfies many light-duty requirements for organizing smaller rack-mount servers and expansion drawers. The 0.6-meter-high rack has a perforated, lockable front door; a heavy-duty caster set for easy mobility; a complete set of blank filler panels for a finished look; EIA unit markings on each corner to aid assembly; and a retractable stabilizer foot. The Model S11 rack has the following specifications: Width: 520 mm (20.5 in.) with side panels Depth: 874 mm (34.4 in.) with front door Height: 612 mm (24.0 in.) Weight: 37 kg (75.0 lb.) The S11 rack has a maximum load limit of 16.5 kg (36.3 lb.) per EIA unit for a maximum loaded rack weight of 216 kg (475 lb.). 1.5.4 IBM 7014 Model S25 rack The 1.3-meter-high Model S25 rack satisfies many light-duty requirements for organizing smaller rack-mount servers. Front and rear rack doors include locks and keys, helping keep your servers secure. Side panels are a standard feature, simplifying ordering and shipping. This 25U rack can be shipped configured and can accept server and expansion units up to 28-inches deep. The front door is reversible so that it can be configured for either left or right opening. The rear door is split vertically in the middle and hinges on both the left and right sides. The S25 rack has the following specifications: 14 IBM System p5 520 and 520Q Technical Overview and Introduction Width: 605 mm (23.8 in.) with side panels Depth: 1001 mm (39.4 in.) with front door Height: 1344 mm (49.0 in.) Weight: 100.2 kg (221.0 lb.) The S25 rack has a maximum load limit of 22.7 kg (50 lb.) per EIA unit for a maximum loaded rack weight of 667 kg (1470 lb.). 1.5.5 S11 rack and S25 rack considerations The S11 and S25 racks do not have vertical mounting space that will accommodate FC 7188 PDUs. All PDUs required for application in these racks must be installed horizontally in the rear of the rack. Each horizontally mounted PDU occupies 1U of space in the rack, and therefore reduces the space available for mounting servers and other components. FC 0469 Customer Specified Rack Placement provides the ability to specify the physical location of the system modules and attached expansion modules (drawers) in the racks. The client’s request is reviewed by eConfig for safe handling by checking the weight distribution within the rack. The Manufacturing Plant provides the final approval for the configuration. This information is then used by IBM Manufacturing to assemble the system components (drawers) in the rack according to the client’s request. The CFReport from eConfig must be submitted to the following site: http://www.ibm.com/servers/eserver/power/csp Table 1-11 on page 16 lists the machine types that are supported in the S11 and S25 racks. Chapter 1. General description 15 Table 1-11 Models supported in S11 and S25 racks Machine type-model Name Supported in: 7014-S11 rack 7014-S25 rack 7037-A50 IBM System p5 185 Y Y 7031-D24/T24 EXP24 Disk Enclosure Y Y 7311-D20 I/O Expansion Drawer Y Y 9110-510 IBM System p5 510 Y Y 9111-520 IBM System p5 520 Y Y 9113-550 IBM System p5 550 Y Y 9115-505 IBM System p5 505 Y Y 9123-710 OpenPower 710 Y Y 9124-720 OpenPower 720 Y Y 9110-51A IBM System p5 510 and 510Q Y Y 9131-52A IBM System p5 520 and 520Q Y Y 9133-55A IBM System p5 550 and 550Q Y Y 9116-561 IBM System p5 560Q Y Y 9910-P33 3000VA UPS (2700 watt) Y Y 9910-P65 500VA UPS (208-240V) N Y 7315-CR3 Rack-mount HMC N Y 7315-CR3 Rack-mount HMC N Y 7026-P16 LAN-attached remote asynchronous node (RAN) N Y 7316-TF3 Rack-mounted flat-panel console kit N Y 1.5.6 The ac power distribution unit and rack content Note: Each server, or system drawer to be mounted in the rack, requires two power cords, which are not included in the base order. For maximum availability, we highly recommend that you connect power cords from the same server or system drawer to two separate PDUs in the rack. These PDUs could be connected to two independent client power sources. For rack models T00 and T42, 12-outlet PDUs (FC 9188 and FC 7188) are available. For rack models S11 and S25, FC 7188 is available. Four PDUs can be mounted vertically in the T00 and T42 racks. See Figure 1-4 on page 17 for the placement of the four vertically mounted PDUs. In the rear of the rack, two additional PDUs can be installed horizontally in the T00 rack and three in the T42 rack. The four vertical mounting locations will be filled first in the T00 and T42 racks. Mounting PDUs horizontally consumes 1U per PDU and reduces the space available for other racked components. When mounting PDUs horizontally, we recommend that you use fillers in the EIA units occupied by these PDUs to facilitate proper air flow and ventilation in the rack. 16 IBM System p5 520 and 520Q Technical Overview and Introduction The S11 and S25 racks support as many PDUs as there is available rack space. For detailed power cord requirements and power cord feature codes, see IBM System p5, IBM Eserver p5 and i5, and OpenPower Edition Planning, SA38-0508. For an online copy, select Map of pSeries books to the information center → Planning → Printable PDFs → Planning at the following Web site: http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp Note: Ensure that the appropriate power cord feature is configured to support the power that is supplied. The Base/Side Mount Universal PDU (FC 9188) and the optional, additional Universal PDU (FC 7188) support a wide range of country requirements and electrical power specifications. The PDU receives power through a UTG0247 power line connector. Each PDU requires one PDU-to-wall power cord. Nine power cord features are available for different countries and applications by varying the PDU-to-wall power cord, which must be ordered separately. Each power cord provides the unique design characteristics for the specific power requirements. To match new power requirements and save previous investments, you can request these power cords with an initial order of the rack or with a later upgrade of the rack features. The PDU has 12 client-usable IEC 320-C13 outlets. There are six groups of two outlets fed by six circuit breakers. Each outlet is rated up to 10 amps. Each group of two outlets is fed from one 15 amp circuit breaker. Note: Based on the power cord that is used, the PDU can supply from 4.8 kVA to 19.2 kVA. The total kilovolt ampere (kVA) of all the drawers plugged into the PDU must not exceed the power cord limitation. The Universal PDUs are compatible with previous models. Figure 1-4 PDU placement and PDU view Chapter 1. General description 17 1.5.7 Rack-mounting rules The primary rules that you should follow when you mount the server into a rack are: The p5-520 or p5-520Q is designed to be placed at any location in the rack. For rack stability, we advise that you start filling a rack from the bottom. Any remaining space in the rack can be used to install other systems or peripherals, provided that the maximum permissible weight of the rack is not exceeded and the installation rules for these devices are followed. Before placing or sliding a p5-520 or p5-520Q into the service position, it is essential that you have followed the rack manufacturer’s safety instructions regarding rack stability. The availability of 14-foot, 9-foot, and 6-foot jumper cords (between the drawer and the PDU) provides several options to ensure that all cables are accounted for inside the rack space. Depending on the current implementation and future enhancements of additional 7311 Model D20 drawers that are connected to the system, Table 1-12 shows examples of the minimum and maximum configurations for different combinations of servers and attached 7311 Model D20 I/O drawers. Table 1-12 Minimum and maximum configurations for servers and 7311-D20s Only servers One server, one 7311-D20 One server, four 7311-D20s 7014-T00 rack 9 4 1 7014-T42 rack 10 5 2 7014-S11 rack 2 1 0 7014-S25 rack 6 3 1 1.5.8 Additional options for the rack This section highlights some solutions available to provide a single point of management for environments composed of multiple p5-520 or p5-520Q servers or other IBM System p5 servers. IBM 7212 Model 103 IBM TotalStorage storage device enclosure The IBM 7212 Model 103 is designed to provide efficient and convenient storage expansion capabilities for selected System p servers. The IBM 7212 Model 103 is a 1U rack-mountable option to be installed in a standard 19-inch rack using an optional rack-mount hardware feature kit. The 7212 Model 103 has two bays that can accommodate any of the following storage drive features: Digital Data Storage (DDS) Gen 5 DAT72 Tape Drive provides a physical storage capacity of 36 GB (72 GB with 2:1 compression) per data cartridge. VXA-2 Tape Drive comes with a media capacity of up to 80 GB (160 GB with 2:1 compression) physical data storage capacity per cartridge. VXA-320 Tape Drive comes with a media physical capacity of up to 160 GB (320 GB with 2:1 compression) physical data storage capacity per cartridge. Half-High LTO-2 Tape Drive comes with media physical capacity of up to 200 GB (400 GB with 2:1 compression) data storage per Ultrium 2 cartridge and a sustained data transfer rate of 24.0 MB per second (48 MB per second with 2:1 compression). In addition to 18 IBM System p5 520 and 520Q Technical Overview and Introduction reading and writing on Ultrium 2 tape cartridges, it is also read and write compatible with Ultrium 1 cartridges. SLR60 Tape Drive (QIC format) comes with 37.5 GB native data physical capacity per tape cartridge and a native physical data transfer rate of up to 4 MB per second and uses 2:1 compression to achieve a single tape cartridge physical capacity up to 75 GB of data. SLR100 Tape Drive (QIC format) comes with 50 GB native data physical capacity per tape cartridge and a native physical data transfer rate of up to 5 MB per second and uses 2:1 compression to achieve single tape cartridge storage of up to 100 GB of data. DVD-RAM 2 drive can read and write on 4.7 GB and 9.4 GB DVD-RAM media. The DVD-RAM 2 uses only bare media, which reduces media costs, and is also read compatible with multisession CD, CD-RW, and 2.6 GB and 5.2 GB DVD-RAM media. The 9.4 GB physical capacity of DVD-RAM allows storage of more data than on conventional CD-R media. Fast performance also allows quick access to information, while downward compatibility helps provide investment protection. Note: Disc capacity options are 2.6 GB and 4.7 GB per side. The 5.2 GB and 9.4 GB capacities can be achieved by using double-sided DVD-RAM discs. Flat panel display options The IBM 7316-TF3 Flat Panel Console Kit can be installed in the system rack. This 1U console uses a 17-inch thin film transistor (TFT) LCD with a viewable area of 337.9 mm x 270.03 mm and a 1280 x 1024 Picture elements (pels) resolution. The 7316-TF3 Flat Panel Console Kit has the following attributes: A 17-inch, flat screen TFT color monitor that occupies only 1U (1.75 inches) in a 19-inch standard rack. Ability to mount the IBM Travel Keyboard in the 7316-TF3 rack keyboard tray. Support for the new 1x8 LCM switch (FC 4280), the Netbay LCM2 (FC 4279) with access to and control of as many as 64 servers, and support of both USB and PS/2 server-side keyboard and mouse connections. IBM Travel Keyboard mounts in the rack keyboard tray (Integrated Track point and UltraNav). IBM PS/2 Travel Keyboards are supported on the 7316-TF3 for use in configurations where only PS/2 keyboard ports are available. The IBM 7316-TF3 Flat Panel Console Kit provides an option for the USB Travel Keyboards with UltraNav. The keyboard enables the 7316-TF3 to be connected to systems that do not have PS/2 keyboard ports. The USB Travel Keyboard can be directly attached to an available integrated USB port or a supported USB adapter (2738) on System p5 servers or 7310-CR3 and 7315-CR3 HMCs. The IBM 7316-TF3 flat-panel, rack-mounted console is now available with two console switch options, which let you inexpensively cable, monitor, and manage your rack servers: the new 1x8 LCM Console Switch (FC 4280) and the LCM2 console switch (FC 4279). The 1x8 Console Switch is a cost-effective, densely-packed solution that helps you set up and control selected System p rack-mounted IBM servers: Supports one local user with PS/2 keyboard, PS/2 mouse, and video connections Features an 8-port, CAT5 console switch for single-user local management Supports both USB and PS/2 server-side keyboard and mouse connections Chapter 1. General description 19 Occupies only 1U (1.75 in) in a 19-inch standard rack The 1x8 Console Switch can be mounted in one of the following racks: 7014-T00, 7014-T42, 7014-S11, or 7014-S25. The 1x8 Console Switch supports GXT135P (FC 1980 and FC 2849) graphics accelerators. The following cables are used to attach the IBM servers to the 1x8 Console Switch: IBM 3M Console Switch Cable (PS/2) (FC 4282) IBM 3M Console Switch Cable (USB) (FC 4281) The 1x8 Console Switch supports the following monitors: 7316-TF3 rack console monitor pSeries TFT monitors (FC 3641, FC 3643, FC 3644, and FC 3645) Separately available switch cables convert KVM signals for CAT5 cabling for servers with USB and PS/2 ports. A minimum of one cable feature (FC 4281) or USB feature (FC 4282) is required to connect the IBM 1x8 Console Switch (FC 4280) to a supported server. The 3-meter cable FC 4281 has one HD15 connector for video and one USB connector for keyboard and mouse. The 3-meter cable FC 4282 has one HD15 connector for video, one PS/2 connector for keyboard, and one PS/2 connector for the mouse and is used to connect the IBM 1x8 Console Switch to a supported server. The 1x8 Console Switch is a 1U (1.75-inch) rack-mountable LCM switch containing eight analog rack interface ports for connecting switches using CAT5 cable. The switch supports a maximum video resolution of 1280x1024. The Console Switch allows for two levels of tiering and supports up to 64 servers at a single user location through switch tiering. The previous VGA switch (FC 4200), the LCM (FC 4202), and LCM2 (FC 4279) switches can be tiered with the 1x8 Console Switch. Note: When the 1x8 Console Switch is tiered with the previous VGA switch (FC 4200) or LCM (FC 4202) switch, it must be at the top level of the tier. When the 1x8 Console Switch is tiered with the LCM2 (FC 4279) switch, it must be at the secondary level of the tier. The IBM Local 2x8 Console Manager (LCM2) switch (FC 4279) provides users single-point access and control of up to 1024 servers. The IBM Local 2x8 Console Manager (LCM2) switch (FC 4279) supports connection to servers with either PS/2 or USB connections with installation of appropriate options. The maximum resolution is 1280 x 1024 at 75 Hz. The LCM2 switch can be tiered, and three levels of tiering are supported. A minimum of one LCM feature (FC 4268) or USB feature (FC 4269) is required with an IBM Local 2x8 Console Manager (LCM2) switch (FC 4279). Each feature can support up to four systems. When connecting to a p5-520 or p5-520Q, FC 4269 provides connection to the POWER5+ USB ports. Only the PS/2 keyboard is supported when attaching the 7316-TF3 to the LCM Switch. When selecting the LCM Switch, consider the following information: The KVM Conversion Option (KCO) cable (FC 4268) is used with systems with PS/2 style keyboard, display, and mouse ports. The USB cable (FC 4269) is used with systems with USB keyboard or mouse ports. 20 IBM System p5 520 and 520Q Technical Overview and Introduction The switch offers four ports for server connections. Each port in the switch can connect a maximum of 16 systems: – One KCO cable (FC 4268) or USB cable (FC 4269) is required for every four systems supported on the switch. – A maximum of 16 KCO cables or USB cables per port can be used with the Netbay LCM Switch to connect up to 64 servers. Note: A server microcode update might be required on installed systems for boot-time System Management Services (SMS) menu support of the USB keyboards. For microcode updates, see: http://www14.software.ibm.com/webapp/set2/firmware/gjsn We recommend that you have the 7316-TF3 installed between EIA 20 and EIA 25 of the rack for ease of use. The 7316-TF3 or any other graphics monitor requires a POWER GXT135P graphics accelerator (FC 1980 and FC 2849) installed in the server, or some other graphics accelerator, if supported. Hardware Management Console 7310 Model CR3 The 7310 Model CR3 Hardware Management Console (HMC) is a 1U, 19-inch rack-mountable drawer that is supported in the 7014 racks. For additional HMC specifications, see 2.13, “Hardware Management Console” on page 60. 1.5.9 OEM rack The p5-520 or p5-520Q can be installed in a suitable OEM rack, provided that the rack conforms to the EIA-310-D standard for 19-inch racks. This standard is published by the Electrical Industries Alliance, and a summary of this standard is available in the publication IBM System p5, IBM Eserver p5 and i5, and OpenPower Planning, SA38-0508. The key points mentioned in this documentation are as follows: The front rack opening must be 451 mm wide + 0.75 mm (17.73 in. + 0.03 in.), and the rail-mounting holes must be 465 mm + 0.8 mm (18.3 in. + 0.03 in.) apart on center (horizontal width between the vertical columns of holes on the two front-mounting flanges and on the two rear-mounting flanges). Figure 1-5 on page 22 shows a top view of the specification dimensions. Chapter 1. General description 21 Figure 1-5 Top view of non-IBM rack specification dimensions The vertical distance between the mounting holes must consist of sets of three holes spaced (from bottom to top) 15.9 mm (0.625 in.), 15.9 mm (0.625 in.), and 12.67 mm (0.5 in.) on center, making each three-hole set of vertical hole spacing 44.45 mm (1.75 in.) apart on center. Rail-mounting holes must be 7.1 mm + 0.1 mm (0.28 in. + 0.004 in.) in diameter. See Figure 1-6 and Figure 1-7 on page 23 for the top and bottom front specification dimensions. Figure 1-6 Rack specification dimensions, top front view 22 IBM System p5 520 and 520Q Technical Overview and Introduction Figure 1-7 Rack specification dimensions, bottom front view It might be necessary to supply additional hardware, such as fasteners, for use in some manufacturer’s racks. The system rack or cabinet must be capable of supporting an average load of 15.9 kg (35 lb.) of product weight per EIA unit. The system rack or cabinet must be compatible with drawer mounting rails, including a secure and snug fit of the rail-mounting pins and screws into the rack or cabinet rail support hole. Note: The OEM rack must only support ac-powered drawers. We strongly recommend that you use a power distribution unit (PDU) that meets the same specifications as the PDUs to supply rack power. Rack or cabinet power distribution devices must meet the drawer power requirements, as well as the requirements of any additional products that will be connected to the same power distribution device. Chapter 1. General description 23 24 IBM System p5 520 and 520Q Technical Overview and Introduction 2 Chapter 2. Architecture and technical overview This chapter discusses the overall system architecture of the p5-520 and p5-520Q. Figure 2-1 details the base system hardware and the DCM or QCM options. (You cannot mix an installation of DCM and QCM options.) The bandwidths in this chapter are theoretical maximums that are provided for reference. We always recommend that you obtain real-world performance measurements using production workloads. 33 MHz SMI-II Enhanced distributed switch 1.9 MB L2 cache C6 Long Long Long Dual SCSI Ultra320 64-bit IDE controller Operator panel 66 MHz 32-bit Slim-line media device Slim-line media device Optional media backplane SMI-II SMI-II Tape drive P4-D1 4-pack disk drive backplane P2-T15-L15-L0 P3-T11-L3-L0 P3-D4 P3-T11-L4-L0 P3-D3 P3-T11-L5-L0 P3-D2 P3-T11-L8-L0 P3-D1 P2-T11-L3-L0 P2-D4 P2-T11-L4-L0 P2-D3 P2-T11-L5-L0 P2-D2 P2-T11-L8-L0 P2-D1 DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” 2x8 B @528 MHz DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” C5 Short PCI-X to PCI-X bridge 3 133 MHz 64-bit @825 MHz 2x16B Short C4 PCI-X to PCI-X bridge 0 36 MB L3 cache 2x16B Enhanced I/O Controller Short RAID enablement card 2x8 B @528 MHz DIMM CX JXX “Ax” Mem ctrl GX+ 700 MHz (DCM) 1056 MHz 2x8 B for read 2x8 B for write SMI-II DIMM CX JXX “Ax” 133 MHz 2x4 B @ 633 MHz Core 1.65 GHz L3 ctrl 36 MB L3 cache QCM 36 MB L3 cache 1056 MHz 2x8 B for read 2x8 B for write Mem ctrl Core 1.65 GHz @825 MHz Core 1.65 GHz L3 ctrl 2x16 B @1.05 GHz DCM 1.9 MB L2 cache Core 1.65 GHz Enhanced distributed switch Enhanced distributed switch To Enhanced I/O Controller Mem Ctrl L3 Ctrl POWER5+ core 2.1 GHz 1.9 MB Shared L2 cache POWER5+ core 2.1 GHz To Enhanced I/O Controller C3 PCI-X slot 6, 64-bit, 133 MHz, 3.3 volts CoD key card buzz interface Dual 1GB Ethernet 64-bit USB 32-bit C2 PCI-X slot 5, 64-bit, 133 MHz, 3.3 volts Service Processor Ethernet ports P1-T5 T6 P1-C1 PCI-X slot 3, 32-bit, 66 MHz, 3.3 volts USB ports P1-T7 T8 PCI-X slot 4, 64-bit, 266 MHz, 3.3 volts RIO-2 bus 2B (Diff’l) Each direction @ 1GB/s PCI-X slot 2, 32-bit, 66 MHz, 3.3 volts Rack Indicator Light System Ports cable port P1-T9 P1-T1 T2 PCI-X slot 1, 64-bit, 133 MHz, 3.3 volts HMC ports P1-C7-T1 T2 Remote I/O card Two SPCN ports P1-C7-T3 T4 4-pack disk drive backplane P3-T14-L15-L0 Figure 2-1 IBM System p5 520 and IBM System p5 520Q architecture with QCM or DCM © Copyright IBM Corp. 2006. All rights reserved. 25 2.1 The POWER5+ processor The IBM POWER5+ processor capitalizes on all the enhancements brought by the POWER5 processor. For a detailed description of the POWER5 processor, refer to IBM System p5 520 Technical Overview and Introduction, REDP-9111. Figure 2-2 shows a high level view of the POWER5+ processor. POWER 5+ Processor Core 2.1 GHz Core 2.1 GHz L3 Bus L3 Intf Mem Bus Mem Cntrl GX+ Intf 1.9 MB L2 GX+ Bus SMP Fabric Bus Enhanced Distributed Switch (Fabric Bus Controller) Vertical Fabric Bus Figure 2-2 Power5+ processor The CMOS10S technology in the POWER5+ processor uses a 90 nanometer or nm fabrication process, which enables: Performance gains through faster clock rates Processor size reduction (243 mm compared with 389 mm) The POWER5+ processor is 37% smaller than the POWER5 processor. It consumes less power and requires less cooling. Thus, you can use the POWER5+ processor in servers where previously you could only use lower frequency processors due to cooling restrictions. The POWER5+ design provides the following additional enhancements: New page sizes in ERAT and TLB. Two new pages sizes (64 KB and 16 GB), which were recently added in PowerPC® architecture. New segment size in SLB. One new segment size (1 TB) was recently added in PowerPC architecture. The TLB size has been doubled in the POWER5+ over the POWER5 processors. The TLB in POWER5+ has 2048 entries. Floating-point round to integer instructions. New instructions (frfin, frfiz, frfip, frfim) have been added to round floating-point numbers with the following rounding modes: nearest, zero, integer plus, and integer minus. Improved floating-point performance. Lock performance enhancement. Enhanced SLB read. True Little-Endian mode. Support for the True Little-Endian mode as defined in the PowerPC architecture. 26 IBM System p5 520 and 520Q Technical Overview and Introduction Double the SMP support. Changes have been made in the fabric, L2 and L3 controller, memory controller, GX controller, and processor RAS to provide support for the QCM that allows the SMP system sizes to be double that which is available in POWER5 DCM-based servers. However, current POWER5+ implementations only support single address loop. Several enhancements have been made in the memory controller for improved performance. The memory controller is ready to support DDR2 667 MHz DIMMs in the future. Enhanced redundancy in L1 cache, L2 cache, and L3 directory. Independent control of the L2 cache and the L3 directory for redundancy to allow split-repair action has been added. More word line redundancy has been added in the L1 Dcache. In addition, Array Built-In Self Test (ABIST) column repair for the L2 cache and the L3 directory has been added. 2.2 Processor and cache In the p5-520 and p5-520Q, the POWER5+ processors, associated L3 cache (if present), and memory DIMMs are packaged on the system planar. The p5-520 1-core, 2-core, and p5-520Q 4-core systems use different POWER5+ processor modules. Note: Because the POWER5+ processor modules are soldered directly to the system planar, you must take special care in sizing and selecting the ideal CPU configuration. 2.2.1 POWER5+ single-core module The 1-core p5-520 POWER5+ system planar contains a single-core module (SCM) and the local memory storage subsystem for that SCM. The POWER5+ single-core processor is packaged in the SCM. The 1-core 1.65 GHz system planar contains a single-core module (SCM) and the local memory storage subsystem for that SCM. L3 Cache is not available in this configuration. Figure 2-3 on page 27 shows the layout of a 1.65 GHz p5-520 SCM and associated memory. DIMM SMI-II DIMM DIMM Single-Core Module SCM GX+ Ctrl POWER5+ core GX+ Bus DIMM 2x8B @528 MHz L3 Ctrl DIMM DIMM DIMM SMI-II DIMM Mem Ctrl 1.9 MB Shared L2 cache Enhanced distributed switch 1056 MHz 2 x 8 B for read 2 x 2 B for write Figure 2-3 p5-520 POWER5+ 1.65 SCM with DDR2 memory socket layout view The 1-core 2.1 GHz p5-520 system planar contains a single-core module (SCM), the local memory storage subsystem for that SCM, and the L3 Cache. Figure 2-4 shows the layout of a 2.1 GHz p5-520 SCM and associated memory. Chapter 2. Architecture and technical overview 27 DIMM SMI-II DIMM DIMM Single-Core Module SCM GX+ Ctrl POWER5+ core GX+ Bus DIMM 2x8B @528 MHz 36 MB L3 cache DIMM SMI-II DIMM DIMM DIMM 2x16B 2:1 L3 Ctrl Mem Ctrl 1.9 MB Shared L2 cache Enhanced distributed switch 1056 MHz 2 x 8 B for read 2 x 2 B for write Figure 2-4 p5-520 POWER5+ 2.1 GHz SCM with DDR2 memory socket layout view The storage structure for the POWER5+ processor is a distributed memory architecture that provides high-memory bandwidth. The processor is interfaced to eight memory slots that are controlled by two Synchronous Memory Interface II (SMI-II) chips, which are located in close physical proximity to the processor module. I/O connects to the p5-520 processor module using the GX+ bus. The processor module provides a single GX+ bus. The GX+ bus provides an interface to I/O devices through the RIO-2 connections. The theoretical maximum throughput of the L3 cache is 16 byte read, 16 byte write at a bus frequency of 1.05 GHz (based on a 2.1 GHz processor clock), which equates to 33600 MBps or 33.60 GBps. Additional throughput details are provided in Table 2-3 on page 33. 2.2.2 The p5-520 POWER5+ dual-core module The 2-core p5-520 system planar contains a dual-core module (DCM) and the local memory storage subsystem for that DCM. The POWER5+ dual-core processor and its associated L3 cache are packaged in the DCM. Figure 2-5 on page 28 shows a layout view of p5-520 DCM and associated memory. DIMM SMI-II DIMM DIMM DCM POWER5+ core 2.1 GHz DIMM 2x8B @528 MHz 36 MB L3 cache DIMM DIMM DIMM SMI-II DIMM 2x16B @1.05 GHz L3 Ctrl Mem Ctrl POWER5+ core 2.1 GHz GX+ Ctrl GX+ Bus 1.9 MB Shared L2 cache Enhanced distributed switch 1056 MHz 2 x 8 B for read 2 x 2 B for write Figure 2-5 The p5-520 POWER5+ 2.1 GHz DCM with DDR2 memory socket layout view The storage structure for the POWER5+ processor is a distributed memory architecture that provides high-memory bandwidth, although each processor can address all memory and 28 IBM System p5 520 and 520Q Technical Overview and Introduction sees a single shared memory resource. They are interfaced to eight memory slots, controlled by two SMI-II chips, which are located in close physical proximity to the processor modules. I/O connects to the p5-520 processor module using the GX+ bus. The processor module provides a single GX+ bus. The GX+ bus provides an interface to I/O devices through the RIO-2 connections. The theoretical maximum throughput of the L3 cache is 16 byte read, 16 byte write at a bus frequency of 1.05 GHz (based on a 2.1 GHz processor clock), which equates to 33600 MBps or 33.60 GBps. Additional throughput details are provided in Table 2-3 on page 33. 2.2.3 The p5-520Q quad-core module The 4-core p5-520Q system planar contains a new quad-core module (QCM) and the local memory storage subsystem for that QCM. Two POWER5+ dual-core processors and their associated L3 cache are packaged in the QCM. Figure 2-6 shows a layout view of a p5-520Q QCM with associated memory. 2x 8B @528 MHz DIMM DIMM QCM SMI-II DIMM DIMM 36 MB L3 cache Core 1.65 GHz L3 ctrl Mem ctrl Mem ctrl DIMM DIMM SMI-II DIMM 2 x 16B 36 MB L3 cache GX+ Ctrl GX+ Bus 2 x 16B @825 MHz 1056 MHz 2 x 8B for read 2 x 2B for write Core 1.65 GHz @825 MHz L3 ctrl Core 1.65 GHz 1.9 MB L2 cache Enhanced distributed switch Enhanced distributed switch 1.9 MB L2 cache Core 1.65 GHz GX+ Ctrl DIMM Figure 2-6 The p5-520Q POWER5+ 1.65 GHz QCM with DDR2 memory socket layout view The storage structure for the POWER5+ processor is a distributed memory architecture that provides high-memory bandwidth. Each processor in the QCM can address all memory and see a single shared memory resource. In the QCM, one POWER5+ processor has direct access to eight memory slots, controlled by two SMI-II chips, which are located in close physical proximity to the processor modules. The other POWER5+ processor has access to the same memory slots through the Vertical Fabric Bus. I/O connects to the p5-520Q QCM using the GX+ bus. The QCM provides a single GX+ bus. One POWER5+ processor has direct access to the GX+ Bus using its GX+ Bus controller and the other uses the Vertical Fabric Bus controlled by the Fabric Bus controller. The GX+ bus provides an interface to I/O devices through the RIO-2 connections. The POWER5+ processor, without direct access to memory, does have a direct access to the GX+ Bus. The theoretical maximum throughput of the L3 cache is 16 byte read, 16 byte write at a bus frequency of 825 MHz (based on a 1.65 GHz processor clock), which equates to 26400 MBps or 26.4 GBps per L3 cache. There are two L3 caches on the QCM, which provide a total L3 cache bandwidth of 52800 MBps or 52.8 GBps per QCM. Additional throughput details are provided in Table 2-3 on page 33. Chapter 2. Architecture and technical overview 29 2.2.4 Available processor speeds Table 2-1 lists the available processor capacities and speeds for the p5-520 and p5-520Q systems. Table 2-1 p5-520 and p5-520Q available processor capacities and speeds p5-520 @ 1.65 GHz p5-520 @ 1.9 GHz p5-520 @ 2.1 GHz p5-520Q @ 1.5 GHz p5-520Q @ 1.65 GHz 1-core Yes No Yes No No 2-core Yes Yes Yes No No 4-core No No No Yes Yes To determine the processor characteristics, use one of the following commands: lsattr -El procX In this command, X is the number of the processor. For example, proc0 is the first processor in the system. The output from the command is similar to the following output (False, as used in this output, signifies that the value cannot be changed through an AIX 5L command interface): frequency 1498500000 smt_enabled true smt_threads 2 state enable type powerPC_POWER5 Processor Processor Processor Processor Processor Speed SMT enabled SMT threads state type False False False False False pmcycles -m The pmcycles command (AIX 5L) uses the performance monitor cycle counter and the processor real-time clock to measure the actual processor clock speed in MHz. The following output is from a 4-core p5-520Q system running at 1.5 GHz with simultaneous multithreading enabled: Cpu Cpu Cpu Cpu 0 1 2 3 runs runs runs runs at at at at 1498 1498 1498 1498 MHz MHz MHz MHz Note: The pmcycles command is part of the bos.pmapi fileset. This component must be installed before using the lslpp -l bos.pmapi command. 2.3 Memory subsystem The p5-520 and p5-520Q servers offer pluggable DDR2 DIMMs for memory. DDR2 DIMMs have a double rate compared with DDR DIMMs (DDR DIMMs have double rate bits compared with SDRM), so that enables up to four times the performance of traditional SDRAM. The system planar provides eight slots for up to eight pluggable DDR2 DIMMs. The minimum memory for a p5-520 or p5-520Q server is 1.0 GB (2 x 512 MB) and 32 GB is the maximum installable memory option. Figure 2-7 shows the memory slot and location codes. All memory is accessed by two Synchronous Memory Interface (SMI)-II chips that are located between the memory and the processor. The SMI-II supports multiple data flow modes. 30 IBM System p5 520 and 520Q Technical Overview and Introduction DIMM CX JXX “Ax” DIMM CX JXX “Ax” DIMM CX JXX “Ax” POWER5+ DCM (Dual-Core Module) or SMI-II DIMM CX JXX “Ax” 2x8 B @528 MHz DIMM CX JXX “Ax” 1056 MHz 2x8 B for read 2x8 B for write DIMM CX JXX “Ax” SMI-II DIMM CX JXX “Ax” QCM (Quad-Core Module) DIMM CX JXX “Ax” First quad Second quad DIMM CX JXX “Ax” J2C DIMM CX JXX “Ax” J2D DIMM CX JXX “Ax” J0D DIMM CX JXX “Ax” J0C DIMM CX JXX “Ax” J0B DIMM CX JXX “Ax” J0A DIMM CX JXX “Ax” SMI-II J2B SMI-II DIMM CX JXX “Ax” 2x8 B @528 MHz J2A Figure 2-7 Memory placement for the p5-520 and p5-520Q servers 2.3.1 Memory placement rules Table 2-2 lists the memory features that are available at the time of writing for the p5-520 and p5-520Q servers. Table 2-2 Available memory features Feature code Description 1930 1 GB (2 x 512 MB) DIMMs, 276-pin DDR2, 533 MHz SDRAM 1931 2 GB (2 x 1 GB) DIMMs, 276-pin DDR2, 533 MHz SDRAM 1932 4 GB (2 x 2 GB) DIMMs, 276-pin DDR2, 533 MHz SDRAM 1934 8 GB (2 x 4 GB) DIMMs, 276-pin DDR2, 533 MHz SDRAM Memory can be pluggable in pairs or quads, as required by the total memory requirement. Memory feature numbers might be mixed within a system. The DIMMs slots are accessed by first removing the PCI riser book. When additional memory is added to a system using FC 1930, an additional feature, FC 1930, must be added to the original pair to make a quad, allowing one additional quad to be added to the system. Memory is installed in the first quad in the following order: J2A, J0A, J2C, and J0C; and for the second quad, in the order J2B, J0B, J2D, and J0D. Memory must be balanced across the DIMM quad slots. The Service Information label, located on the top cover of the system, provides memory DIMMs slot location information. Chapter 2. Architecture and technical overview 31 To determine how much memory is installed in a system, use the following command: # lsattr -El sys0 | grep realmem realmem 524288 Amount of usable physical memory in Kbytes False Note: A quad must consist of a single feature (that is, be made of identical DIMMs). Mixed DIMM capacities in a quad will result in reduced RAS. 2.3.2 OEM memory OEM memory is not supported or certified by IBM for use in an IBM System p5 server. If the server is populated with OEM memory, you could experience unexpected and unpredictable behavior, especially when the system is using Micro-Partitioning technology. All IBM memory is identified by an IBM logo and a white label that is printed with a barcode and an alphanumeric string, as illustrated in Figure 2-8. Figure 2-8 IBM memory certification label 2.3.3 Memory throughput The memory subsystem throughput is based on the speed of the memory. An elastic interface, contained in the POWER5+ processor, buffers reads and writes to and from memory and the processor. There are two Synchronous Memory Interface (SMI-II) chips, each with a single 8-byte read and 2-byte write high speed Elastic Interface-II bus to the memory controller of the processor. The bus allows double reads or writes per clock cycle. Because the bus operates at 1066 MHz, the peak processor-to-memory throughput for read is (8 x 2 x 1056) = 16896 MBps or 16.89 GBps. The peak processor-to-memory throughput for write is (2 x 2 x 1056) = 4224 MBps or 4.22 GBps, making a total of 21.12 GBps. The 533 MHz DDR2 memory DIMMS operate at 528 MHz through four 8-byte paths. Read and write operations share these paths. There must be at least four DIMMs installed to effectively use each path. In this case, the throughput between the SMI-II and the DIMMs is (8 x 4 x 528) or 16.89 GBps. These values are maximum theoretical throughputs for comparison purposes only. Table 2-3 provides the theoretical throughput values for different configurations. 32 IBM System p5 520 and 520Q Technical Overview and Introduction Table 2-3 Theoretical throughput rates Processor speed (GHz) Processor Type Cores Memory (GBps) L2 to L3 (GBps) GX+ (GBps) 1.65 POWER5+ 1-core 21.1 26.4 4.4 1.65 POWER5+ 2-core 21.1 26.4 4.4 1.9 POWER5+ 2-core 21.1 30.4 5.1 2.1 POWER5+ 1-core 21.1 33.6 5.6 2.1 POWER5+ 2-core 21.1 33.6 5.6 1.5 POWER5+ 4-core 21.1 48 4 1.65 POWER5+ 4-core 21.1 52.8 4.4 2.4 I/O buses This section provide additional information that is related to the internal RIO-2 buses and GX+ buses. The QCM or DCM provides a GX+ bus. In the past, the 6XX bus was the front end from the processor to memory, PCI Host bridge, cache, and other devices. The follow-on to the 6XX bus is the GX bus, connecting the processor to the I/O subsystems. Compared with the 6XX bus, the GX+ bus is both wider and faster and connects to the Enhanced I/O Controller. The Enhanced I/O Controller is a GX+ to PCI and PCI-X 2.0 Host bridge chip. It contains a GX+ passthru port and four PCI-X 2.0 buses. The GX+ passthru port allows other GX+ bus hubs to be connected into the system. Each Enhanced I/O Controller can provide four separate PCI-X 2.0 buses. Each PCI-X 2.0 bus is 64 bits in width and individually capable of running either PCI, PCI-X, or PCI-X 2.0 (DDR only). The p5-520 and p5-520Q systems do not have RIO-2 ports integrated on the system planar to connect supported external I/O subsystems. As shown in Figure 2-9 on page 34, one Remote I/O expansion card (FC 2888) is required to connect the supported external I/O subsystems. When this card is present, the Enhanced I/O Controller routes the GX+ bus to the external RIO-2 ports. Chapter 2. Architecture and technical overview 33 External I/O Subsystem (up to 4 7311-D20) RIO-2 Card GX+ Bus DCM or QCM Enhanced I/O Controller Internal I/O Subsystem Memory System Planar Processor Card Figure 2-9 p5-520 or p5-520Q GX+ Bus connection overview According to the processor speed, the I/O subsystem is capable of supporting 5.6 GBps when using the 2.1 GHz processor, or capable of supporting 4.4 GBps when using a 1.65 GHz processor. The bus is a dual four-byte wide bus running at a 3:1 processor to bus ratio. 2.5 Internal I/O subsystem PCI-X, where the X stands for extended, is an enhanced PCI bus, delivering a bandwidth of up to 2 GBps, running a 64-bit bus at 133 MHz or 266 MHz. PCI-X is backward compatible, so the systems can support existing 3.3 volt PCI adapters. The system planar provides six PCI-X slots and several integrated I/O devices. The PCI-X slot 1, slot 5, and slot 6 are 64-bit capable running at 133 MHz. The PCI-X slot 2 and slot 3 are 32-bit capable running at 66 MHz, but PCI-X 64-bit short adapters can be used in these slots. All the PCI-X slots and the integrated I/O devices, except the PCI-X slot 4, are connected through two EADS-X chips that function as PCI-X to PCI-X bridges to the Enhanced I/O Controller. The connections of the PCI-X slots and integrated I/O devices to the PCI-X to PCI-X bridges are properly distributed to maximize the system performances. The first three PCI-X slots can accept a short PCI-X or PCI card. The remaining PCI-X slots are full length cards. PCI-X slot 4 is a PCI-X DDR 266 MHz and 64 bit capable slot and is driven by the Enhanced I/O Controller directly. The dual 10/100/1000 Mbps Ethernet adapter and the Dual Channel SCSI Ultra320 adapter are some of the integrated devices on the system planar. The PCI-X slots in the p5-520 and p5-520Q system support hot-plug and Extended Error Handling (EEH). In the unlikely event of a problem, EEH-enabled adapters respond to a special data packet generated from the affected PCI-X slot hardware by calling system firmware, which will examine the affected bus, allow the device driver to reset it, and continue without a system reboot. 34 IBM System p5 520 and 520Q Technical Overview and Introduction 2.6 64-bit and 32-bit adapters IBM offers 64-bit adapter options for the p5-520 and p5-520Q, as well as 32-bit adapters. Higher-speed adapters use 64-bit slots because they can transfer 64 bits of data for each data transfer phase. Generally, 32-bit adapters can function in 64-bit PCI-X slots; however, some 64-bit adapters cannot be used in 32-bit slots. For a full list of the adapters that are supported on the systems and for important information regarding adapter placement, see the IBM Systems Hardware Information Center at: http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp The internal PCI-X slots support a wide range of PCI-X I/O adapters to handle your I/O requirements. 2.6.1 LAN adapters To connect a p5-520 or p5-520Q to a local area network (LAN), you can use the dual port internal 10/100/1000 Mbps RJ-45 Ethernet controller that is integrated on the system planar. Table 2-4 lists the additional LAN adapters that are available for an initial system order at the time of writing. IBM supports an installation with NIM using Ethernet and token-ring adapters (CHRP1 is the platform type). Token-ring is not allowed as the initial order. Table 2-4 Available LAN adapters Feature code Adapter description Type Slot Size Max 1954 4-port 10/100/1000 Ethernet Copper 32 or 64 Short 4 1978 Gigabit Ethernet Fibre 32 or 64 Short 6 1979 Gigabit Ethernet Copper 32 or 64 Short 6 5721 10 Gigabit Ethernet - short reach Fibre 32 or 64 Short 3 5722 10 Gigabit Ethernet - long reach Fibre 32 or 64 Short 3 1983 2-port Gigabit Ethernet Copper 32 or 64 Short 6 1984 2-port Gigabit Ethernet Fibre 32 or 64 Short 6 2.6.2 SCSI adapters To connect to external SCSI devices, the adapters that are provided in Table 2-5 are available, at the time of writing, to be configured with an initial order. Table 2-5 Available SCSI adapters Feature code Adapter description Slot Size Max 1912 Dual Channel Ultra320 SCSI 64 Short 6 1913 Dual Channel Ultra320 SCSI RAID 64 Long 3 Note: Previous SCSI adapters are also supported for use in the p5-520 and p5-520Q but cannot be part of an initial order configuration. If you want to connect existing external SCSI devices, contact your IBM service representative. 1 CHRP stands for Common Hardware Reference Platform, a specification for PowerPC-based systems that can run multiple operating systems. Chapter 2. Architecture and technical overview 35 You also have the option to make the internal Ultra320 SCSI channel externally accessible on the rear side of the system by installing FC 4275. No additional SCSI adapter is required in this case. If FC 4275 is installed, a second 4-pack disk enclosure (FC 6574 or FC 6594) cannot be installed, which limits the maximum number of internal disks to four. Slot 5 cannot be used when FC 4275 is installed. For more information about the internal SCSI system, see 2.7, “Internal storage” on page 41. 2.6.3 Integrated RAID options The p5-520 and p5-520Q can be configured with the optional SCSI RAID daughter card (FC 1907) that plugs directly on the system board or with a Dual Channel Ultra320 SCSI RAID adapter (FC 1913) to drive one 4-pack disk enclosure. RAID implementation requires a minimum of three disk drives to form a RAID set. Important: RAID Capacity limitation. There are limits to the amount of disk drive capacity allowed in a single RAID array. Using the 32-bit AIX 5L kernel, there is a capacity limitation of 1 TB per RAID array. Using the 64 bit kernel, there is a capacity limitation of 2 TB per RAID array. For RAID adapter and RAID enablement cards, this limitation is enforced by AIX 5L when RAID arrays are created using the PCI-X SCSI Disk Array Manager. These are different internal RAID options that you can consider: Install FC 1907 and up to 4 disk drives in the default 4-pack disk enclosure. This allows RAID capabilities within a single 4-pack. Install FC 1907 and a second 4-pack disk enclosure (FC 6574). This allows RAID capabilities across two 4-packs. Install FC 1907 (or later) and the Ultra320 SCSI 4-Pack Enclosure for Disk Mirroring (FC 6594). Install the PCI-X Dual Channel Ultra320 SCSI RAID adapter (FC 1913) and the SCSI cable (FC 4267), which connects the PCI-X adapter to the optional 4-pack disk enclosure. This RAID configuration provides increased reliability over first and second options Note: Because the p5-520 and p5-520Q have up to eight disk drive slots, if you are upgrading, you must plan appropriately to ensure the correct handling of your RAID arrays. 2.6.4 iSCSI iSCSI is an open, standards-based approach by which SCSI information is encapsulated using the TCP/IP protocol to allow its transport over IP networks. It allows transfer of data between storage and servers in block I/O formats (that is defined by iSCSI protocol) and thus enables the creation of IP SANs. iSCSI allows an existing network to transfer SCSI commands and data with full location independence and defines the rules and processes to accomplish the communication. The iSCSI protocol is defined in iSCSI IETF draft-20. For more information about this standard, see: http://tools.ietf.org/html/rfc3720 Although iSCSI can be, by design, supported over any physical media that supports TCP/IP as a transport, today's implementations are only on Gigabit Ethernet. At the physical and link level layers, iSCSI supports Gigabit Ethernet and its frames so that systems supporting iSCSI can be directly connected to standard Gigabit Ethernet switches and IP routers. iSCSI also enables the access to block-level storage that resides on Fibre Channel SANs over an IP network using iSCSI-to-Fibre Channel gateways such as storage routers and switches. 36 IBM System p5 520 and 520Q Technical Overview and Introduction The iSCSI protocol is implemented on top of the physical and data-link layers and presents to the operating system a standard SCSI Access Method command set. It supports SCSI-3 commands and reliable delivery over IP networks. The iSCSI protocol runs on the host initiator and the receiving target device. It can either be optimized in hardware for better performance on an iSCSI host bus adapter (such as FC 1986 and FC 1987 supported in IBM System p5 servers) or run in software over a standard Gigabit Ethernet network interface card. IBM System p5 systems support iSCSI in the following two modes: Hardware Using iSCSI adapters (see “IBM iSCSI adapters” on page 37). Software Supported on standard Gigabit adapters, additional software (see “IBM iSCSI software Host Support Kit” on page 38) must be installed. The main processor is utilized for processing related to the iSCSI protocol. Initial iSCSI implementations are targeted at small to medium-sized businesses and departments or branch offices of larger enterprises that have not deployed Fibre Channel SANs. iSCSI is an affordable way to create IP SANs from a number of local or remote storage devices. If Fibre Channel is present, which is typical in a data center, it can be accessed by the iSCSI SANs (and vice versa) via iSCSI-to-Fibre Channel storage routers and switches. iSCSI solutions always involve the following software and hardware components: Initiators These are the device drivers and adapters that reside on the client. They encapsulate SCSI commands and route them over the IP network to the target device. Targets The target software receives the encapsulated SCSI commands over the IP network. The software can also provide configuration support and storage-management support. The underlying target hardware can be a storage appliance that contains embedded storage, and it can also be a gateway or bridge product that contains no internal storage of its own. IBM iSCSI adapters New iSCSI adapters in IBM System p5 systems provide the advantage of increased bandwidth through the hardware support of the iSCSI protocol. The 1 Gigabit iSCSI TOE (TCP/IP Offload Engine) PCI-X adapters support hardware encapsulation of SCSI commands and data into TCP and transports them over the Ethernet using IP packets. The adapter operates as an iSCSI TOE. This offload function eliminates host protocol processing and reduces CPU interrupts. The adapter uses a Small form factor LC type fiber optic connector or a copper RJ45 connector. Table 2-6 provides the orderable iSCSI adapters. Table 2-6 provides the orderable iSCSI adapters. Table 2-6 Available iSCSI adapters Feature code Description Slot Size Max 1986 Gigabit iSCSI TOE PCI-X on copper media adapter 64 Short 3 1987 Gigabit iSCSI TOE PCI-X on optical media adapter 64 Short 3 Chapter 2. Architecture and technical overview 37 IBM iSCSI software Host Support Kit The iSCSI protocol can also be used over standard Gigabit Ethernet adapters. To utilize this approach, download the appropriate iSCSI Host Support Kit for your operating system from the IBM NAS support Web site at: http://www.ibm.com/storage/support/nas/ The iSCSI Host Support Kit on AIX 5L and Linux acts as a software iSCSI initiator and allows you to access iSCSI target storage devices using standard Gigabit Ethernet network adapters. To ensure the best performance, enable the TCP Large Send, TCP send and receive flow control, and Jumbo Frame features of the Gigabit Ethernet Adapter and the iSCSI Target. Tune network options and interface parameters for maximum iSCSI I/O throughput on the operating system. IBM System Storage N series The combination of IBM System p5 and IBM System Storage™ N series as the first of a whole new generation of iSCSI-enabled storage products provides an End-to-End set of solutions. Currently, the System Storage N series feature three models: N3700, N5200, and N5500. All models provide: Support for entry-level and midrange clients requiring Network Attached Storage (NAS) or Internet Small Computer System Interface (iSCSI) functionality Support for Network File System (NFS), Common Internet File System (CIFS), and iSCSI protocols Data ONTAP software (at no charge), with plenty of additional functions such as data movement, consistent snapshots, and NDMP server protocol, some available through optional licensed functions Enhanced reliability with optional clustered (2-node) failover support 2.6.5 Fibre Channel adapter The p5-520 and p5-520Q servers support direct or SAN connection to devices using Fibre Channel adapters. Single-port Fibre Channel adapters are available in 2 Gbps and 4 Gbps speeds. A dual-port 4 Gbps Fibre Channel adapter is also available. Table 2-7 provides a summary of the available Fibre Channel adapters. All of these adapters have LC connectors. If you are attaching a device or switch with an SC type fibre connector, then an LC-SC 50 Micron Fiber Converter Cable (FC 2456) or an LC-SC 62.5 Micron Fiber Converter Cable (FC 2459) is required. Supported data rates between the server and the attached device or switch are as follows: Distances of up to 500 meters running at 1 Gbps, distances up to 300 meters running at 2 Gbps data rate, and distances up to 150 meters running at 4 Gbps. When these adapters are used with IBM supported Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at 1 Gbps, 2 Gbps, and 4 Gbps data rates. 38 IBM System p5 520 and 520Q Technical Overview and Introduction Table 2-7 Available Fibre Channel adapters Feature code Description Slot Size Max 1905 4 Gigabit single-port Fibre Channel PCI-X 2.0 Adapter (LC) 64 Short 6 1910 4 Gigabit dual-port Fibre Channel PCI-X 2.0 Adapter (LC) 64 Short 6 1977 2 Gigabit Fibre Channel PCI-X Adapter (LC) 64 Short 6 2.6.6 Graphic accelerators The p5-520 and p5-520Q support up to four enhanced POWER GXT135P (FC 1980) 2D graphic accelerators. The POWER GXT135P is a low-priced 2D graphics accelerator for IBM System p5 servers. This adapter supports both analog and digital monitors and is supported for System Management Services (SMS), firmware, and other functions, as well as when AIX 5L or Linux starts an X11-based graphic user interface (GUI). 2.6.7 InfiniBand Host Channel adapter The p5-520 and p5-520Q support the RIO-2 expansion cards (FC 2888) to connect the supported additional I/O subsystems. The server also supports one GX Dual-port 4x InfiniBand Host Channel Adapter (FC 1812) that enables the attachment of the Topspin Server Switch models 120 and 270. Only a single GX Dual-port 4x InfiniBand HCA or RIO-2 expansion card can plug into the system planar, using the GX slot, at a time. Connection to the Topspin Server Switches is accomplished by using the 4x IB Cables. Topspin Server Switch models 120 and 270 Switches are the fundamental components of an InfiniBand fabric. An IBM System p5 server proposal might also include the Topspin Server Switch model 120 and 270 in an initial system order. The Topspin Server Switch models 120 and 270 are programmable switching platforms that consist of a switched multiple-terabit interconnect and an intelligent control architecture. The high-bandwidth, low-latency interconnection is extremely adaptable. The switches enable an outstanding level of application scaling, rapid deployment, and resource consolidation. For more information about Topspin Server Switch, see: http://www.topspin.com/solutions/ 2.6.8 Asynchronous PCI-X adapters Asynchronous PCI-X adapters provide connection of asynchronous EIA-232 or RS-422 devices. If you have a cluster configuration or high-availability configuration and plan to connect the IBM System p5 servers using a serial connection, the use of the two default ports is not supported. You should use one of the features listed in Table 2-8. Table 2-8 Asynchronous PCI-X adapters Feature code Description 2943 8-Port Asynchronous Adapter EIA-232/RS-422 5723 2-Port Asynchronous IEA-232 PCI Adapter Chapter 2. Architecture and technical overview 39 In many cases, the 5723 asynchronous adapter is configured to supply a backup HACMP heartbeat. In these cases, a serial cable (FC 3927 or FC 3928) must be also configured. Both of these serial cables and the 5723 adapter have 9-pin connectors. 2.6.9 PCI-X Cryptographic Coprocessor The PCI-X Cryptographic Coprocessor (FIPS 4) (FC 4764) for selected System p servers provides both cryptographic coprocessor and secure-key cryptographic accelerator functions in a single PCI-X card. The coprocessor functions are targeted to banking and finance applications. Financial PIN processing and credit card functions are provided. EMV is a standard for integrated chip-based credit cards. The securekey accelerator functions are targeted to improving the performance of Secure Sockets Layer (SSL) transactions. The FC 4764 provides the security and performance required to support On Demand Business and emerging digital signature application. The PCI-X Cryptographic Coprocessor (FIPS 4) (FC 4764) for selected System p servers provides both cryptographic coprocessor and secure-key cryptographic accelerator functions in a single PCI-X card. The FC 4764 provides secure storage of cryptographic keys in a tamper resistant hardware security module (HSM), which is designed to meet FIPS 140 security requirements. FIPS 140 is a U.S. Government National Institute of Standards & Technology (NIST)-administered standard and certification program for cryptographic modules. The firmware for the FC 4764 is available on a separately ordered and distributed CD. This firmware is an LPO product: 5733-CY1 Cryptographic Device Manager. The FC 4764 also requires LPP 5722-AC3 Cryptographic Access Provider to enable data encryption. Note: This feature has country-specific usage. Refer to the IBM representatives in your country for availability or restrictions. 2.6.10 Additional support for PCI-X adapters you own The lists of the major PCI-X adapters that you can configure in a p5-520 or p5-520Q when you build an initial configuration order are described in 2.6.1, “LAN adapters” on page 35 through 2.6.8, “Asynchronous PCI-X adapters” on page 39. The list of all the supported PCI-X adapters, with the related support for additional external devices, is more extended. If you would like to use PCI-X adapters you already own, contact your IBM service representative to verify whether those adapters are supported. 2.6.11 Internal system ports The system ports S1 and S2, at the rear of the system, are only available if the system is not managed using a Hardware Management Console (HMC). In this case, the S1 and S2 ports support the attachment of a serial console and a modem and are of limited function. If an HMC is connected, a virtual serial console is provided by the HMC (logical device vsa0 under AIX 5L), and you can also connect a modem to the HMC. The S1 and S2 ports are not usable in this case. If you need serial port function, optional PCI adapters are available. For more information, see 2.6.8, “Asynchronous PCI-X adapters” on page 39. 40 IBM System p5 520 and 520Q Technical Overview and Introduction 2.6.12 Ethernet ports The two built-in Ethernet ports provide 10/100/1000 Mbps connectivity over CAT-5 cable for up to 100 meters. Table 2-9 lists the attributes of the LEDs that are visible on the side of the jack. Table 2-9 Ethernet LED descriptions LED Light Description Link Off Green No link; could indicate a bad cable, not selected, or configuration error. Connection established. On Off Data activity. Idle. Activity 2.7 Internal storage There is one dual channel Ultra320 SCSI controller that is managed by the EADS-X chips, integrated into the system planar, and that is used to drive the internal disk drives. The eight internal drives plug into the disk drive backplane, which has two separate SCSI buses with four disk drives per bus. The internal disk drive can be used in two different modes based on whether the SCSI RAID Enablement Card (FC 1976) is installed (see 2.6.3, “Integrated RAID options” on page 36). The p5-520 and p5-520Q supports two 4-pack disk drives using a backplane that is designed for hot-pluggable disk drives. The disk drive backplane docks directly to the system planar. The virtual SCSI Enclosure Services (VSES) hot-plug control functions are provided by the Ultra320 SCSI controllers. 2.7.1 Internal media devices The p5-520 and p5-520Q provide two slim-line media bays for optional DVD-ROM (FC 1994) and optional DVD-RAM (FC 1993) and one media bay for a tape drive. Table 2-10 shows all additional media devices for the systems. Table 2-10 Available optical and tape drives Feature code Description 1993 4.7 GB IDE Slimline DVD-RAM drive 1994 IDE Slimline DVD-ROM drive 1892 VXA-320 160/320 GB Internal Tape Drive 1991 36/72 GB 4 mm Internal Tape Drive 1992 IBM 80/160 GB Internal Tape Drive with VXA Technology 1997 200/400 GB Half High Ultrium 2 Tape Drive 2.7.2 Internal hot-swappable SCSI disks The p5-520 and p5-520Q can have up to eight hot-swappable disk drives plugged in the two 4-pack disk drive backplanes. The hot-swappable process is controlled by the SCSI enclosure service (SES), which is located in the 4-pack disk drives backplane (AIX 5L Chapter 2. Architecture and technical overview 41 assigns the name ses0 to the first 4-pack, and ses1 to the second, if present). The two hot-swappable 4-pack disk drive backplanes can accommodate the devices listed in Table 2-11. Table 2-11 Available hot-swappable disk drives Feature code Description 1968 73.4 GB ULTRA320 10 K rpm SCSI hot-swappable disk drive 1969 146.8 GB ULTRA320 10 K rpm SCSI hot-swappable disk drive 1970 36.4 GB ULTRA320 15 K rpm SCSI hot-swappable disk drive 1971 73.4 GB ULTRA320 15 K rpm SCSI hot-swappable disk drive 1972 146.8 GB ULTRA320 15 K rpm SCSI hot-swappable disk drive 1973 300 GB ULTRA320 10 K rpm SCSI hot-swappable disk drive At the time of writing, if a new order is placed with two 4-pack DASD backplanes (FC 6574) and more than one disk, the system configuration shipped from manufacturing balances the total number of SCSI disks between the two 4-pack SCSI backplanes. This is for manufacturing test purposes and not because of any limitation. Having the disks balanced between the two 4-pack DASD backplanes allows the manufacturing process to systematically test the SCSI paths and devices related to them. Prior to the hot-swap of a disk in the hot-swap capable bay, all necessary operating system actions must be undertaken to ensure that the disk is capable of being deconfigured. After the disk drive has been deconfigured, the SCSI enclosure device will power off the slot, enabling safe removal of the disk. You should ensure that the appropriate planning has been given to any operating system-related disk layout, such as the AIX 5L Logical Volume Manager, when using disk hot-swap capabilities. For more information, see Problem Solving and Troubleshooting in AIX 5L, SG24-5496. Note: After you have deconfigured the disk, we recommend that you follow this procedure when removing a hot-swappable disk: 1. 2. 3. 4. Release the tray handle on the disk. Pull out the disk assembly a little bit from the original position. Wait up to 20 seconds until the internal disk stops spinning. Now, you can safely remove the disk from the 4-pack DASD backplane. After the SCSI disk hot-swap procedure, you can expect to find SCSI_ERR10 logged in the AIX 5L error log, with the second word of the sense data equal to 0017. This error is generated from a SCSI bus reset that is issued by the SES to reset all processes when a drive is inserted, and this error is not an issue. Hot-swappable disks and Linux Hot-swappable disk drives on IBM System p5 systems are supported with SUSE Linux Enterprise Server 9 for POWER, or later, and Red Hat Enterprise Linux AS for POWER Version 3, or later. 42 IBM System p5 520 and 520Q Technical Overview and Introduction 2.8 External I/O subsystem This section describes the external I/O subsystem, the 7311 D20 I/O drawer that is the only drawer supported on the p5-520 and p5-520Q systems. 2.8.1 I/O drawers As described in Chapter 1, “General description” on page 1, the p5-520 or p5-520Q systems have six internal PCI-X slots, which is enough in many cases. If more PCI-X slots are needed to dedicate more adapters to a partition or to increase the bandwidth of network adapters, up to four 7311 Model D20 I/O drawers can be added to the p5-520 or p5-520Q systems. The p5-520 or p5-520Q systems have a standard RIO-2 bus to connect the internal PCI-X slots through the PCI-X to PCI-X bridges and support up to four external I/O drawers. An optional RIO-2 adapter (FC 2888) is required for external RIO-2 devices, such as I/O drawers. The 7311 Model D20 I/O drawer must have the RIO-2 loop adapter (FC 6417) to be connected to the p5-520 or p5-520Q systems. The PCI-X host bridge inside the I/O drawer provides two primary 64-bit PCI-X buses running at 133 MHz. Therefore, a maximum bandwidth of 1 GBps is provided by each bus. To avoid overloading an I/O drawer, you should follow the recommendation in the IBM System p5 Hardware Information Center at: http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp Figure shows a conceptual diagram of the 7311 Model D20 I/O drawer subsystem. PCI-X Host B ridge 133 M Hz, 64-bit PCI-X RIO 133 M Hz, 64-bit PCI-X PC I-X Bridge PC I-X Bridge 1 2 3 4 5 6 7 6 4 / 1 3 3 6 4 / 1 3 3 6 4 / 1 3 3 6 4 / 1 3 3 6 4 / 1 3 3 6 4 / 1 3 3 6 4 / 1 3 3 Figure 2-10 Conceptual diagram of the 7311-D20 I/O drawer 7311 Model D20 internal SCSI cabling A 7311 Model D20 supports hot-swappable disks using two 6-pack disk bays for a total of 12 disks. Additionally, the SCSI cables (FC 4257) are used to connect a SCSI adapter (that can have various features) in slot 7 to each of the 6-packs, or two SCSI adapters, one in slot 4 and one in slot 7 (Figure ). Chapter 2. Architecture and technical overview 43 Connect the SCSI cable feature to the SCSI adapter in rightmost slot (7) as shown below: If a SCSI card is also placed in slot 4, wire as shown below: to 6-pack backplanes to 6-pack backplanes SCSI cables FC 4257 SCSI cables FC 4257 Figure 2-11 7311 Model D20 internal SCSI cabling Note: Any 6-packs and the related SCSI adapter can be assigned to a partition. If one SCSI adapter is connected to both 6-packs, both 6-packs can be assigned only to the same partition. When the server is configured with the Advanced POWER Virtualization hardware feature and the Virtual I/O Server is used for virtual SCSI, the disks can be shared between partitions. 2.8.2 7311 I/O drawer RIO-2 cabling As described in 2.8, “External I/O subsystem” on page 43, you can connect up to four I/O drawers in the same loop to the p5-520 or p5-520Q system. Each RIO-2 port can operate at 1 GHz in bidirectional mode and is capable of passing data in each direction on each cycle of the port. Therefore, the maximum data rate is 4 GBps per I/O drawer in double barrel mode. There is one default primary RIO-2 loop in any p5-520 or p5-520Q system. This feature provides two Remote I/O ports for attaching up to four 7311 Model D20 I/O drawers to the system in a single loop. Figure shows how you could connect four I/O drawers to one system. 44 IBM System p5 520 and 520Q Technical Overview and Introduction PCI-X slots FC 2888 I/O drawer #1 I/O drawer #2 I/O drawer #3 I/O drawer #4 Figure 2-12 RIO-2 connections The RIO-2 cables used have different lengths to satisfy the different connection requirements: Remote I/O cable, 1.2 m (FC 3146) Remote I/O cable, 1.75 m (FC 3156) Remote I/O cable, 2.5 m (FC 3168) Remote I/O cable, 3.5 m (FC 3147) Remote I/O cable, 10 m (FC 3148) 2.8.3 7311 Model D20 I/O drawer SPCN cabling The SPCN is used to control and monitor the status of power and cooling within the I/O drawer. The SPCN is a loop, the cabling starts from SPCN port 0 on the p5-520 or p5-520Q system to SPCN port 0 on the first I/O drawer. The loop is closed connecting the SPCN port 1 of the I/O drawer back to the port 1 of the p5-520 or p5-520Q system. If you have more than one I/O drawer, you continue the loop connecting the following drawer (or drawers) with the same rule. Figure shows SPCN cabling examples. Chapter 2. Architecture and technical overview 45 Primary drawer Primary drawer SPCN port 0 SPCN port 0 SPCN port 1 SPCN port 1 I/O drawer or secondary drawer I/O drawer or secondary drawer SPCN port 0 SPCN port 0 SPCN port 1 SPCN port 1 I/O drawer or secondary drawer SPCN port 0 SPCN port port 1 1 SPCN Figure 2-13 SPCN cabling examples There are different SPCN cables to satisfy different length requirements: SPCN cable drawer to drawer, 2 m (FC 6001) SPCN cable drawer to drawer, 3 m (FC 6006) SPCN cable rack to rack, 6 m (FC 6008) SPCN cable rack to rack, 15 m (FC 6007) SPCN cable rack to rack 30 m (FC 6029) 2.9 External disk subsystems The p5-520 and p5-520Q have internal hot-swappable drives. When the AIX 5L operating system is installed in a IBM System p5 servers, the internal disks are usually used for the AIX 5L rootvg volume group and paging space. Specific client requirements can be satisfied with the several external disk possibilities that the system supports. 2.9.1 IBM TotalStorage EXP24 Expandable Storage The IBM TotalStorage® EXP24 Expandable Storage disk enclosure, Model D24 or T24, can be purchased together with the p5-520 or p5-520Q and will provide low-cost Ultra320 (LVD) SCSI disk storage. This disk storage enclosure device provides more than 7 TB of disk storage in a 4U rack-mount (Model D24) or compact deskside (Model T24) unit. Whether high availability storage solutions or simply high capacity storage for a single server installation, the unit provides a cost-effective solution. It provides 24 hot-swappable disk bays, 12 accessible from the front and 12 from the rear. Disk options that can be accommodate in any of the four six-packs disk drive enclosure are 73.4 GB, 146.8 GB or 300 GB 10K rpm or 46 IBM System p5 520 and 520Q Technical Overview and Introduction 36.4 GB, 73.4 GB or 146.8 GB 15K rpm drives. Each of the four six-packs disk drive enclosure can be attached independently to an Ultra320 SCSI or Ultra320 SCSI RAID adapter. For high available configurations, a dual bus repeater card (FC 5742) allows each six-pack to be attached to two SCSI adapters, installed in one or multiple servers or logical partitions. Optionally, the two front or two rear six-packs can be connected together to form a single Ultra320 SCSI bus of 12 drives. 2.9.2 IBM System Storage N3000 and N5000 The IBM System Storage N3000 and N5000 line of iSCSI-enabled storage offerings provides the flexibility for implementing a Storage Area Network over an Ethernet network. The N3000 supports up to 16.8 TB of physical storage and the N5000 supports up to 84 TB of physical disk. Additional information about IBM iSCSI-based storage systems is available at: http://www.ibm.com/servers/storage/nas/index.html 2.9.3 IBM TotalStorage DS4000 Series The IBM System Storage DS4000™ line of Fibre Channel-enabled Storage offerings provides a wide range of storage solutions for your Storage Area Network (SAN). The DS4000 Storage server family consists of the following models: DS4100, DS4300, DS4500, and DS4800. The Model DS4100 Express model is the smallest model and scales up to 44.8 TB; the Model DS4800 is the largest and scales up to 89.6 TB of disk storage at the time of this writing. Model DS4300 provides up to 16 bootable partitions, or 64 bootable partitions if the turbo option is selected, that are attached with a Fibre Channel Adapter. Model DS4500 provides up to 64 bootable partitions. Model DS4800 provides 4 GB switched interfaces. In most cases, both the IBM TotalStorage DS4000 family and the IBM System p5 servers are connected to a storage area network. If you only need space for the rootvg, the Model DS4100 is a good solution. For support of additional features and for further information about the IBM TotalStorage DS4000 Storage Server family, refer to the following Web site: http://www.ibm.com/servers/storage/disk/ds4000/index.html 2.9.4 IBM TotalStorage DS6000 and DS8000 Series The IBM TotalStorage Models DS6000™ and DS8000™ are the high-end premier storage solution for use in storage area networks and use POWER technology-based design to provide fast and efficient serving of data. The IBM TotalStorage DS6000 provides enterprise class capabilities in a space-efficient modular package. It scales to 67.2 TB of physical storage capacity by adding storage expansion enclosures. The Model DS8000 series is the flagship of the IBM TotalStorage DS family. The DS8000 scales to 192 TB; however, the system architecture is designed to scale to over one petabyte. The Model DS6000 and DS8000 systems can also be used to provide disk space for booting logical partitions (LPARs) or partitions using Micro-Partitioning technology. DS6000 and DS8000 and the IBM System p5 servers are usually connected together to a storage area network. For further information about ESS, refer to the following Web site: http://www.ibm.com/servers/storage/disk/enterprise/ds_family.html Chapter 2. Architecture and technical overview 47 2.10 Logical partitioning Dynamic logical partitions (LPARs) and virtualization increase utilization of system resources and add a new level of configuration possibilities. This section provides details and configuration specifications about this topic. The virtualization discussion includes virtualization enabling technologies that are standard on the system, such as the POWER Hypervisor™, and optional ones, such as the Advanced POWER Virtualization feature. 2.10.1 Dynamic logical partitioning Logical partitioning (LPAR) was introduced with the POWER4 processor-based product line and the AIX 5L Version 5.1 operating system. This technology offered the capability to divide a pSeries system into separate logical systems, allowing each LPAR to run an operating environment on dedicated attached devices, such as processors, memory, and I/O components. Later, dynamic LPAR increased the flexibility, allowing selected system resources, such as processors, memory, and I/O components, to be added and deleted from dedicated partitions while they are executing. AIX 5L Version 5.2, with all the necessary enhancements to enable dynamic LPAR, was introduced in 2002. The ability to reconfigure dynamic LPARs encourages system administrators to dynamically redefine all available system resources to reach the optimum capacity for each defined dynamic LPAR. Operating system support for dynamic LPAR Table 2-12 lists AIX 5L and Linux support for dynamic LPAR capabilities. Table 2-12 Operating system supported function Function AIX 5L Version 5.2 AIX 5L Version 5.3 Linux SLES 9 Linux RHEL AS 3 Linux RHEL AS 4 Dynamic LPAR capabilities (add, remove, and move operations) Processor Y Y Y N Y Memory Y Y N N N I/O slot Y Y Y N Y 2.11 Virtualization With the introduction of the POWER5 processor, partitioning technology moved from a dedicated resource allocation model to a virtualized shared resource model. This section briefly discusses the key components of virtualization on IBM System p servers. For more information about virtualization, see the following Web site: http://www.ibm.com/servers/eserver/about/virtualization/systems/pseries.html You can also consult the following IBM Redbooks: Advanced POWER Virtualization on IBM System p5, SG24-7940 http://www.redbooks.ibm.com/abstracts/sg247940.html?Open Advanced POWER Virtualization on IBM Sserver p5 Servers: Architecture and Performance Considerations, SG24-5768 http://www.redbooks.ibm.com/abstracts/sg245768.html?Open 48 IBM System p5 520 and 520Q Technical Overview and Introduction 2.11.1 POWER Hypervisor Combined with features designed into the POWER5 and POWER5+ processors, the POWER Hypervisor delivers functions that enable other system technologies, including Micro-Partitioning technology, virtualized processors, IEEE VLAN, compatible virtual switch, virtual SCSI adapters, and virtual consoles. The POWER Hypervisor is a basic component of system firmware that is always active, regardless of the system configuration. The POWER Hypervisor provides the following functions: Provides an abstraction between the physical hardware resources and the logical partitions using them. Enforces partition integrity by providing a security layer between logical partitions. Controls the dispatch of virtual processors to physical processors. (For more information, see 2.12.2, “Logical, virtual, and physical processor mapping” on page 52.) Saves and restores all processor state information during logical processor context switch. Controls hardware I/O interrupt management facilities for logical partitions. Provides virtual LAN channels between physical partitions that help to reduce the need for physical Ethernet adapters for inter-partition communication. The POWER Hypervisor is always active when the server is running, whether the server is partitioned or not, and also even when the server is not connected to the HMC. It requires memory to support the logical partitions on the server. The amount of memory required by the POWER Hypervisor firmware varies according to several factors. Factors influencing the POWER Hypervisor memory requirements include the following: Number of logical partitions Partition environments of the logical partitions Number of physical and virtual I/O devices used by the logical partitions Maximum memory values given to the logical partitions Note: Use the System Planning Tool to estimate the memory requirements of the POWER Hypervisor. In AIX 5L V5.3, the lparstat command using the -h and -H flags displays the POWER Hypervisor statistical data. Using the -h flag adds summary POWER Hypervisor statistics to the default lparstat output. The minimum amount of physical memory for each partition is 128 MB, but in most cases the actual requirements and recommendations are between 256 MB and 512 MB for AIX 5L, Red Hat Linux, and Novell SUSE Linux. Physical memory is assigned to partitions in increments of Logical Memory Block (LMB). For POWER5+ processor-based systems, LMB can be adjusted from 16 MB to 256 MB. The POWER Hypervisor provides the following types of virtual I/O adapters: Virtual SCSI Virtual Ethernet Virtual (TTY) console Virtual SCSI The POWER Hypervisor provides a virtual SCSI mechanism for virtualization of storage devices (a special logical partition to install the Virtual I/O Server is required to use this feature, see 2.12.3, “Virtual I/O Server” on page 54). The storage virtualization is accomplished using two paired adapters: a virtual SCSI server adapter and a virtual SCSI Chapter 2. Architecture and technical overview 49 client adapter. Only the Virtual I/O Server partition can define virtual SCSI server adapters, other partitions are client partitions. The Virtual I/O Server is available with the optional Advanced POWER Virtualization feature (FC 7940). Virtual Ethernet The POWER Hypervisor provides a virtual Ethernet switch function that allows partitions on the same server to use a fast and secure form of communication without any need for physical interconnection. The virtual Ethernet allows a transmission speed in the range of 1 to 3 GBps. depending on the maximum transmission unit (MTU) size and CPU entitlement. Virtual Ethernet requires a system with either AIX 5L Version 5.3 or an appropriate level of Linux supporting virtual Ethernet devices (see 2.14, “Operating system support” on page 64). The virtual Ethernet is part of the base system configuration. Virtual Ethernet has the following major features: The virtual Ethernet adapters can be used for both IPv4 and IPv6 communication and can transmit packets with a size up to 65408 bytes. Therefore, the maximum MTU for the corresponding interface can be up to 65394 (65390 if VLAN tagging is used). The POWER Hypervisor presents itself to partitions as a virtual 802.1Q compliant switch. Maximum number of VLANs is 4096. You can configure virtual Ethernet adapters as either untagged or tagged (following IEEE 802.1Q VLAN standard). A partition supports 256 virtual Ethernet adapters. Besides a default port VLAN ID, the number of additional VLAN ID values that can be assigned per virtual Ethernet adapter is 20, which implies that each virtual Ethernet adapter can be used to access 21 virtual networks. Each partition operating system detects the virtual local area network (VLAN) switch as an Ethernet adapter without the physical link properties and asynchronous data transmit operations. Any virtual Ethernet can also have connection outside of the box if a layer-2 bridging to a physical Ethernet adapter is set in one Virtual I/O Server partition (see 2.12.3, “Virtual I/O Server” on page 54 for more details about shared Ethernet). Note: Virtual Ethernet is based on the IEEE 802.1Q VLAN standard. No physical I/O adapter is required when creating a VLAN connection between partitions, and no access to an outside network is required. Virtual (TTY) console Each partition needs to have access to a system console. Tasks such as operating system installation, network setup, and some problem analysis activities require a dedicated system console. The POWER Hypervisor provides the virtual console using a virtual TTY or serial adapter and a set of Hypervisor calls to operate on them. Virtual TTY does not require the purchase of any additional features or software such as the Advanced POWER Virtualization feature. Depending on the system configuration, the operating system console can be provided by the Hardware Management Console virtual TTY, IVM virtual TTY, or from a terminal emulator connected to a system port. 50 IBM System p5 520 and 520Q Technical Overview and Introduction 2.12 Advanced POWER Virtualization feature The Advanced POWER Virtualization feature (FC 7940) is an optional, additional cost feature. This feature enables the implementation of more fine-grained virtual partitions on IBM System p5 servers. The Advanced POWER Virtualization feature includes: Firmware enablement for Micro-Partitioning technology. Support for up to 10 partitions per processor using 1/100 of the processor granularity. Minimum CPU requirement per partition is 1/10. All processors are enabled for micro-partitions (the number of processors on the system equals the number of Advanced POWER Virtualization features ordered). Installation image for the Virtual I/O Server software that is shipped as a system image on DVD. Client partitions can be either AIX 5L Version 5.3 or Linux. It supports: – Ethernet adapter sharing (Ethernet bridge from virtual Ethernet to external network). – Virtual SCSI Server. – Partition management using Integrated Virtualization Manager (Virtual I/O Server Version 1.2 or later only). Partition Load Manager (AIX 5L Version 5.3 only) – Automated CPU and memory reconfiguration. – Real-time partition configuration and load statistics. – Graphical user interface. For more details about Advanced POWER Virtualization and virtualization in general, see: http://www.ibm.com/servers/eserver/pseries/ondemand/ve/resources.html 2.12.1 Micro-Partitioning technology The concept of Micro-Partitioning technology allows you to allocate fractions of processors to the partition. The Micro-Partitioning technology is only available with POWER5 and POWER5+ processor-based systems. From an operating system perspective, a virtual processor cannot be distinguished from a physical processor, unless the operating system has been enhanced to be made aware of the difference. Physical processors are abstracted into virtual processors that are available to partitions. See 2.12.2, “Logical, virtual, and physical processor mapping” on page 52 for more details. When defining a shared partition, you have to define several options: Minimum, desired, and maximum processing units. Processing units are defined as the processing power, or the fraction of time, that the partition is dispatched on physical processors. The processing sharing mode, either capped or uncapped. Weight (preference) in the case of an uncapped partition. Minimum, desired, and maximum number of virtual processors. POWER Hypervisor calculates a partition’s processing entitlement based on its desired processing units and logical processor settings, sharing mode, and also based on other active partitions’ requirements. The actual entitlement is never smaller than the desired processing unit’s value and can exceed the desired processing unit’s value if the LPAR is an uncapped partition. Chapter 2. Architecture and technical overview 51 A partition can be defined with a processor capacity as small as 0.10 processing units. This represents one-tenth of a physical processor. Each physical processor can be shared by up to 10 shared processor partitions, and a partition’s entitlement can be incremented fractionally by as little as one-hundredth of the processor. The shared processor partitions are dispatched and time-sliced on the physical processors under control of the POWER Hypervisor. The shared processor partitions are created and managed by the HMC or Integrated Virtualization Management (included with Virtual I/O Server software version 1.2 or later). There is only one pool of shared processors at the time of writing this publication and all shared partitions are dispatched by Hypervisor within this pool. Dedicated partitions and micro-partitions can coexist on the same POWER5+ processor-based server as long as enough processors are available. The systems support up to a 4-core processor configuration, therefore, up to four dedicated partitions, or up to 40 micro-partitions can be created. It is important to point out that the maximums stated are supported by the hardware, but the practical limits depend on the application workload demands. 2.12.2 Logical, virtual, and physical processor mapping The meaning of the term physical processor in this section is a processor core. For example, in a 2-core server with a DCM (dual-core module), there are two physical processors, and in a 4-core configuration with a QCM (quad-core module), there are four physical processors. In dedicated mode, physical processors are assigned as a whole to partitions. The simultaneous multithreading feature in the POWER5+ processor core allows the core to execute instructions from two independent software threads simultaneously. To support this feature, the concept of logical processors was introduced. The operating system (AIX 5L or Linux) sees one physical processor as two logical processors if the simultaneous multithreading feature is on. It can be turned off while operating system is executing (for AIX 5L, use the smtctl command). If simultaneous multithreading is off, then each physical processor is presented as one logical processor, and, thus, only one thread is executed on the physical processor at the time. In a micro-partitioned environment with shared mode partitions, an additional concept of virtual processors was introduced. Shared partitions can define any number of virtual processors (maximum number is 10 times the number of processing units assigned to the partition). From the POWER Hypervisor point of view, the virtual processors represent dispatching objects (for example, the POWER Hypervisor dispatches virtual processors to physical processors according to partition’s processing unit entitlement). At the end of the POWER Hypervisor’s dispatch cycle, all partitions should receive total CPU time equal to their processing unit entitlement. Virtual processors are either running (dispatched) on a physical processor or standby (waiting). The operating system is able to dispatch its software threads to these virtual processors and is completely screened from the actual number of physical processors. The logical processors are defined on top of virtual processors in the same way that physical processors are defined. So, even with a virtual processor, the concept of logical processor exists and the number of logical processors depends on whether the simultaneous multithreading is turned on or off. Some additional information related to the virtual processors: There is a one-to-one mapping of running virtual processors to physical processors at any given time. No more virtual processors can be active at any given time than the total number of physical processors in the shared processor pool. A virtual processor can be either running (dispatched) on a physical processor or standby waiting for a physical processor to become available. 52 IBM System p5 520 and 520Q Technical Overview and Introduction Virtual processors do not introduce any additional abstraction level, they are really only a dispatch entity. When running on a physical processor, they run at the full speed of the physical processor. Each partition’s profile defines a CPU entitlement that determines how much processing power any given partition should receive. The total sum of CPU entitlement of all partitions cannot exceed the number of available physical processors in the shared processor pool. A partition has the same amount of processing power regardless of the number of virtual processors that it defines. A partition can use more processing power, regardless of its entitlement, if it is defined as an uncapped partition in the partition profile. If there is spare processing power available in the shared processor pool or other partitions are not using their entitlement, an uncapped partition can use additional processing units if its entitlement is not enough to satisfy its application processing demand in the given processing entitlement. When the partition is uncapped, the number of defined virtual processors determines the limitation of the maximum processing power it can receive. For example, if the number of virtual processors is two, then the maximum usable processor units is two. You are allowed to define more virtual processors than physical processors. In that case, the virtual processor is waiting for dispatch more often, and you should consider some performance impact caused by redispatching virtual processors on physical processors. Also, some applications might benefit from using more virtual processors than physical processors. You can change the number of virtual processors dynamically through a dynamic LPAR operation. Virtual processor recommendations For each partition, you can define a number of virtual processors set to the maximum processing power the partition could ever request. If there are, for example, four physical processors installed in the system, one production partition and three test partitions, then: Define the production LPAR with four virtual processors, so that it can receive full processing power of all four physical processors during the time that the other partitions are idle. If you know that the test system never consumes more than one processor computing unit, then you should define the test system with one virtual processor. Some test systems might require additional virtual processors, such as four, in order to use idle processing power left over by a production system during off-business hours. Figure 2-14 on page 54 shows logical, virtual, and physical processor mapping, and an example of how the virtual processor and logical processor can be dispatched to the physical processor. Chapter 2. Architecture and technical overview 53 virtual processor (VP3) dispatched dispatched virtual processor (VP4) virtual processor (VP0) virtual processor (VP0) virtual processor (VP1) . dispatched physical CPU (proc0) physical CPU (proc1) logical CPU 1 logical CPU 0 logical CPU 3 logical CPU 2 logical CPU 1 logical CPU 0 logical CPU 0 logical CPU 9 logical CPU 8 logical CPU 7 logical CPU 6 logical CPU 5 virtual processor (VP2) LPAR4 dedicated 1 physical CPU SMT ON shared mode 2 virual CPU's SMT ON allways dispatched virtual processor (VP1) logical CPU 4 logical CPU 3 logical CPU 2 logical CPU 1 OS level - operating sytem (AIX, Linux) only sees logical processors logical CPU 0 virtual processor (VP0) LPAR3 - LPAR2 shared mode 1 virual CPU SMT OFF shared mode 5 virual CPU's SMT ON physical level virtual level LPAR1 - physical CPU (proc2) physical CPU (proc3) shared pool dedicated HW - physical resources driven by Hypervisor sample time 0 msec LPAR1 VP0 LP0+1 LPAR1 VP2 LP4+5 LPAR1 entitlement = 0.5 LPAR2 entitlement = 0.5 LPAR3 entitlement = 1.0 Physical CPU proc1 LPAR1 VP2 LP2+3 LPAR1 VP3 LP6+7 Physical CPU proc2 LPAR3 VP0 LP0+1 LPAR1 VP4 LP8+9 Spare Processing units LPAR2 VP0 LP0 Spare Physical CPU proc0 Dispatching example with: 10 msec LPAR3 VP1 LP2+3 LPAR3 VP1 LP2+3 LPAR3 VP0 LP0+1 Spare Processing units Spare Processing units Figure 2-14 Logical, virtual, and physical processor mapping In Figure 2-14, a system with four physical processors and four partitions is presented; one partition (LPAR4) is in dedicated mode and three partitions (LPAR1, LPAR2, and LPAR3) are running in shared mode. Dedicated mode LPAR4 is using one physical processor and, thus, three processors are available for shared processor pool. The LPAR1 defines five virtual processors and the simultaneous multithreading feature is on (thus, it sees 10 logical processors). LPAR2 defines one virtual processor and simultaneous multithreading is off (one logical processor). LPAR3 defines two virtual processors and simultaneous multithreading is on. Currently (sample time), virtual processors 2 and 3 of LPAR1 and virtual processor 0 of LPAR2 are dispatched on physical processors in the shared pool. Other virtual processors are idle waiting for dispatch by the Hypervisor. When more virtual processors are defined within a partition, any virtual processors share equal parts of the partition processing entitlement. 2.12.3 Virtual I/O Server The Virtual I/O Server (VIOS) is a special purpose partition that provides virtual I/O resources to other partitions. The Virtual I/O Server owns the physical resources (actually SCSI, Fibre Channel and network adapters, and optical devices) and allows client partitions to share access to them, thus, minimizing the number of physical adapters in the system. The Virtual I/O Server eliminates the requirement that every partition own a dedicated network adapter, disk adapter, and disk drive. Figure 2-15 on page 55 shows an organization view of a micro-partitioned system including the Virtual I/O Server. The figure also includes virtual SCSI and Ethernet connections and mixed operating system partitions. 54 IBM System p5 520 and 520Q Technical Overview and Introduction POWER5 Partitioning Network 2 CPUs 3 CPUs 3 CPUs AIX v5.3 AIX v5.3 AIX v5.2 Linux Virtual adapter AIX v5.3 Linux Virtual SCSI Linux Virtual I/O Server External storage 6 CPUs Micro-Partitioning AIX v5.3 2 CPUs Virtual Ethernet POWER Hypervisor I/O Storage Network I/O I/O I/O Sto Net Sto Net Sto Net I/O HMC S N Figure 2-15 Micro-Partitioning technology and VIOS Because the Virtual I/O Server is an operating system-based appliance server, redundancy for physical devices attached to the Virtual I/O Server can be provided by using capabilities such as Multipath I/O and IEEE 802.3ad Link Aggregation. Installation of the Virtual I/O Server partition is performed from a special system backup DVD that is provided to clients that order the Advanced POWER Virtualization feature. This dedicated software is only for the Virtual I/O Server (and IVM in case it is used) and is only supported in special Virtual I/O Server partitions. The Virtual I/O Server can be installed by: Media (assigning the DVD-ROM drive to the partition and booting from the media) The HMC (inserting the media in the DVD-ROM drive on the HMC and using the installios command) Using the Network Install Manager (NIM) Note: To increase the performance of I/O-intensive applications, use dedicated physical adapters using dedicated partitions. We recommend that you install the Virtual I/O Server in a partition with dedicated resources or at least a 0.5 processor entitlement to help ensure consistent performance. The Virtual I/O Server supports RAID configurations and SAN-attached devices (possibly with multipath driver). Logical volumes created on RAID or JBOD configurations are bootable, and the number of logical volumes is limited to the amount of storage available and architectural limits of the Logical Volume Manager. Two major functions are provided with the Virtual I/O Server: a shared Ethernet adapter and Virtual SCSI. Chapter 2. Architecture and technical overview 55 Shared Ethernet adapter A shared Ethernet adapter (SEA) is a Virtual I/O Server service that acts as a layer 2 network bridge between a physical Ethernet adapter or aggregation of physical adapters (EtherChannel) and one or more Virtual Ethernet adapters defined by the Hypervisor on the Virtual I/O Server. A SEA enables LPARs on the virtual Ethernet to share access to the physical Ethernet and communicate with stand-alone servers and LPARs on other systems. The shared Ethernet network provides this access by connecting the internal Hypervisor VLANs with the VLANs on the external switches. Because the shared Ethernet network processes packets at layer 2, the original MAC address and VLAN tags of the packet are visible to other systems on the physical network. IEEE 802.1 VLAN tagging is supported. The virtual Ethernet adapters that are used to configure a shared Ethernet adapter are required to have the trunk setting enabled. The trunk setting causes these virtual Ethernet adapters to operate in a special mode, so that they can deliver and accept external packets from the POWER5+ internal switch to the external physical switches. The trunk setting should only be used for the virtual Ethernet adapters that are part of a shared Ethernet network setup in the Virtual I/O server. A single SEA setup can have up to 16 virtual Ethernet trunk adapters and each virtual Ethernet trunk adapter can support up to 20 VLAN networks. Therefore, it is possible for a single physical Ethernet to be shared between 320 internal VLANs. The number of shared Ethernet adapters that can be set up in a Virtual I/O Server partition is limited only by the resource availability because there are no configuration limits. For a more detailed discussion about virtual networking, see: http://www.ibm.com/servers/aix/whitepapers/aix_vn.pdf Virtual SCSI Access to real storage devices is implemented through the virtual SCSI services, a part of the Virtual I/O Server partition. You accomplish this by using a pair of virtual adapters: a virtual SCSI server adapter and a virtual SCSI client adapter. The virtual SCSI server and client adapters are configured using an HMC or through Integrated Virtualization Manager on smaller systems. The virtual SCSI server (target) adapter is responsible for executing any SCSI commands it receives. It is owned by the Virtual I/O Server partition. The virtual SCSI client adapter allows a client partition to access physical SCSI and SAN-attached devices and LUNs that are assigned to the client partition. Physical disks owned by the Virtual I/O Server partition can either be exported and assigned to a client partition as a whole device, or they can be configured into a volume group and partitioned into several logical volumes. These logical volumes can then be assigned to individual partitions. From the client partition point of view, these two options are equivalent. The Virtual I/O Server provides mapping between backing devices (physical devices or logical volumes assigned to client partitions in VIOS nomenclature) and client partitions by a command line interface. The appropriate command is the mkvdev command. For syntax and semantics, see Virtual I/O Server documentation. All current storage device types, such as SAN, SCSI, and RAID are supported. SSA and iSCSI are not supported at the time of writing. For more information about the specific storage devices supported, see: http://techsupport.services.ibm.com/server/vios/home.html 56 IBM System p5 520 and 520Q Technical Overview and Introduction Important: We do not recommend using Mirrored Logical Volumes (LVs) on the Virtual I/O Server level for as backing devices. If mirroring is required, two independent devices (possibly from two separate VIO servers) should be assigned to the client partition, and then the client partition should define mirroring on top of them. Virtual I/O Server version 1.3 Virtual I/O Server version 1.3 brings a host of new enhancements, including improved monitoring such as additional topas and viostat performance metrics and the bundling of the Performance ToolKit (PTX®) agent. Virtual SCSI and Virtual Ethernet performance increases, and command line enhancements and the enablement of additional storage solutions are also included. Virtual I/O Server version 1.3 introduced several enhancements for Virtual SCSI and shared Fibre Channel adapter support: Independent Software Vendor/Independent Hardware Vendor Virtual I/O enablement iSCSI TOE adapter iSCSI directly attached n3700 storage subsystem HP storage Virtual SCSI functional enhancements: – Support for SCSI Reserve/Release for limited configurations – Changeable queue depth – Updating virtual device capacity non-disruptively so that the virtual disk can "grow" without requiring a reconfig – Configurable fast fail time (number of retries on failure) – Error log enhancements Virtual I/O Server version 1.3 also introduced several enhancements for virtual Ethernet and shared ethernet adapter support, including TCP/IP Acceleration: Large Block Send. 2.12.4 Partition Load Manager Partition Load Manager (PLM) provides automated processor and memory distribution between a dynamic LPAR and a Micro-Partitioning technology capable logical partition running AIX 5L. The PLM application is based on a client/server model to share system information, such as processor or memory events, across the concurrent present logical partitions. The following events are registered on all managed partition nodes: Memory-pages-steal high thresholds and low thresholds Memory-usage high thresholds and low thresholds Processor-load-average high threshold and low threshold Note: PLM is supported on AIX 5L Version 5.2 and AIX 5L Version 5.3. It is not supported on Linux. 2.12.5 Integrated Virtualization Manager In order to ease virtualization technology adoption in any IBM System p5 environment, IBM has developed Integrated Virtualization Manager (IVM) — a simplified hardware Chapter 2. Architecture and technical overview 57 management solution that inherits some HMC features, thus avoiding the necessity of a dedicated control workstation. This solution enables the administrator to reduce system setup time. IVM is targeted at small and medium systems. IVM supports up to the maximum 16-core configuration. The IVM provides a management model for a single system. Although it does not provide the full flexibility of an HMC, it enables the exploitation of the IBM Virtualization Engine™ technology. IVM is an enhancement of the Virtual I/O Server, offered as part of Virtual I/O Server Version 1.2 and follow-on versions, which is the product that enables I/O virtualization in POWER5 and POWER5+ systems. It provides the same Virtual I/O Server features plus a Web-based graphical user interface that enables the administrator to remotely manage the System p5 server with an Internet browser. You can use IVM to: Create and manage logical partitions. Configure the virtual Ethernet networks. Manage storage in the Virtual I/O Server. Create and manage user accounts. Create and manage serviceable events through Service Focal Point. Download and install updates to device microcode and to Virtual I/O Server software. Back up and restore logical partition configuration information. View application logs and the device inventory. The requirements for an IVM-managed server are as follows: A server managed by IVM cannot be simultaneously managed by an HMC. IVM (with Virtual I/O Server) must be installed as the first operating system. An IVM partition requires a minimum of one virtual processor and 512 MB of RAM. Virtual I/O Server version 1.3 introduced enhancements to IVM. The Integrated Virtualization Manager (IVM) adds an industry leading function in this release: support for Dynamic Logical Partitioning (DLPAR) for memory and processors in managed partitions. Additionally, a number of usability enhancements include support through the browser-based interface for IP configuration of the Virtual I/O Server: DLPAR Support for memory and processors in managed partitions GUI Support for System Plan management, including the Logical Partition (LPAR) Deployment Wizard Web UI Support for: – IP configuration support – Task Manager for long-running tasks – Various usability enhancements, including the ability to create a new partition based on an existing one The major considerations of IVM in comparison to an HMC-managed system are as follows: All physical adapters are owned by IVM, and LPARs use virtual devices. There is only one profile per partition. A maximum of four virtual Ethernet networks are available inside the system. Each LPAR can have a maximum of one Virtual SCSI adapter assigned. IVM supports a single Virtual I/O Server to support all of your mission critical production needs. Service Agent (see 3.2.3, “Service Agent” on page 85) for reporting Hardware errors to IBM is not available on IVM. 58 IBM System p5 520 and 520Q Technical Overview and Introduction IVM cannot be used by HACMP software to activate Capacity on Demand (CoD) resources on machines that support CoD. IVM provides advanced virtualization functionality without the need for an extra-cost workstation. For more information about IVM functionality and best practices, see Virtual I/O Server Integrated Virtualization Manager, REDP-4061 at this Web site: http://www.ibm.com/systems/p/hardware/meetp5/ivm.pdf Figure 2-16 shows how a system with IVM is organized. There is a Virtual I/O Server and IVM installed in one partition that owns all of the physical server resources and four client partitions. IVM communicates to the POWER Hypervisor to create, manage, and provide virtual I/O for client partitions. But the dispatch of partitions on physical processors is done by the POWER Hypervisor as in HMC-managed servers. The rules for mapping the physical processors, virtual processors, and logical processors apply for shared partitions managed by the HMC as discussed in 2.12.2, “Logical, virtual, and physical processor mapping” on page 52. Figure 2-16 IVM principles Note: IVM and HMC are two separate management systems and cannot be used at the same time. IVM targets ease of use, while HMC targets flexibility and scalability. The internal design is so different that you should never connect an HMC to a working IVM system. If you want to migrate an environment from IVM to HMC, you have to rebuild the configuration setup manually. Operating system support for advanced virtualization Table 2-13 on page 60 lists AIX 5L and Linux support for advanced virtualization. Chapter 2. Architecture and technical overview 59 Table 2-13 Operating system supported functions Advanced POWER Virtualization feature AIX 5L Version 5.2 AIX 5L Version 5.3 Linux SLES 9 Linux RHEL AS 3 Linux RHEL AS 4 Micro-partitions (1/10th of processor) N Y Y Y Y Virtual Storage N Y Y Y Y Virtual Ethernet N Y Y Y Y Partition Load Manager Y Y N N N 2.13 Hardware Management Console The Hardware Management Console (HMC) is a dedicated workstation that provides a graphical user interface for configuring, operating, and performing basic system tasks for the IBM System p5 servers that function in either non-partitioned, LPAR, or clustered environments. In addition, the HMC is used to configure and manage partitions. One HMC is capable of controlling multiple POWER5 and POWER5+ processor-based systems. At the time of writing, one HMC supports up to 48 POWER5 and POWER5+ processor-based systems and up to 254 LPARs using the HMC machine code Version 5.2. For updates of the machine code and HMC functions and hardware prerequisites, refer to the following Web site: https://www14.software.ibm.com/webapp/set2/sas/f/hmc/home.html POWER5+ and POWER5 processor-based system HMCs require Ethernet connectivity between the HMC and the server’s service processor. Moreover, if dynamic LPAR operations are required, all AIX 5L and Linux partitions must be enabled to communicate over a network to the HMC. Ensure that sufficient Ethernet adapters are available to enable public and private networks, if you need both: The HMC 7310 Model C05 is a deskside model with one integrated 10/100/1000 Mbps Ethernet port and two additional PCI slots. The 7310 Model CR3 is a 1U, 19-inch rack-mountable drawer that has two native 10/100/1000 Mbps Ethernet ports and two additional PCI slots. For any partition in a server, it is possible to use the shared Ethernet adapter in the Virtual I/O Server for a unique connection from the HMC to the partitions. Therefore, your partition does not require your own physical adapter to communicate to an HMC. It is a good practice to connect the HMC to the first HMC port on the server, which is labeled as HMC Port 1, although other network configurations are possible. You can attach a second HMC to HMC Port 2 of the server for redundancy (or vice versa). Figure 2-17 on page 61 shows a simple network configuration to enable the connection from the HMC to the server and to enable Dynamic LPAR operations. For more details about HMC and the possible network connections, refer to Hardware Management Console (HMC) Case Configuration Study for LPAR Management, REDP-3999, at: http://www.redbooks.ibm.com/abstracts/redp3999.html 60 IBM System p5 520 and 520Q Technical Overview and Introduction Management LAN Service Processor LPAR n HMC 1 LPAR... eth0 ` LPAR 2 eth1 LPAR 1 eth0 eth0 eth0 eth0 HMC 2 HMC p5 System Figure 2-17 HMC to service processor and LPARs network connection The default mechanism for allocation of the IP addresses for the service processor HMC ports is dynamic. The HMC can be configured as a DHCP server, providing the IP address at the time the managed server is powered on. If the service processor of the managed server does not receive the DHCP reply before time-out, predefined IP addresses set up on both ports. Static IP address allocation is also an option. You can configure the IP address of the service processor ports with a static IP address by using the Advanced System Management Interface (ASMI) menus. See 2.15.7, “Service processor” on page 73 for predefined IP addresses and additional information. Note: If you need to access ASMI (for example, to set up the IP address of a new POWER5+ processor-based server when HMC is not available or not providing DHCP services), you can connect any client to one of the service processor HMC ports with any kind of Ethernet cable, and use a Web browser to access the predefined IP address, such as the following example: https://192.168.2.147 Functions performed by the HMC include: Creating and maintaining a multiple partition environment Displaying a virtual operating system session terminal for each partition Displaying a virtual operator panel of contents for each partition Detecting, reporting, and storing changes in hardware conditions Powering managed systems on and off Acting as a service focal point The HMC provides both graphical and command line interface for all management tasks. Remote connection to the HMC using Web-based System Manager or SSH is possible. For accessing the graphical interface, you can use the Web-based System Manager Remote Client running on the AIX 5L, Linux, or Windows® operating systems. The Web-based System Manager client installation image can be downloaded from the HMC itself from the following URL: http:///remote_client.html Both unencrypted and encrypted Web-based System Manager connections are supported. The command line interface is also available by using the SSH secure shell connection to the HMC. The command line interface can be used by an external management system or a partition to perform HMC operations remotely. Chapter 2. Architecture and technical overview 61 2.13.1 High availability using the HMC The HMC is an important hardware component. HACMP Version 5.3 High Availability cluster software can be used to activate resources automatically (where available), thus becoming an integral part of the cluster. For some environments, we recommend that you work with redundant HMCs. eth0 HMC2 eth0 HMC1 LAN 1 1 LAN3 - outside connection eth1 eth1 POWER5 and POWER5+ processor-based systems have two service processor interfaces (HMC port 1 and HMC port 2) available for connections to the HMC. We recommend that you use both of them for redundant network configuration. Depending on your environment, you have multiple options to configure the network. Figure 2-18 shows one possible highly available configuration. 2 LAN 2 1 LAN1 – hardware management network for first FSP ports (private) LAN2 – hardware management network for second FSP ports (private), separate network hardware than LAN1 LAN3 - management network for WebSM access to HMC from outside (public) and for HMC to LPAR communication 2 FSP FSP p5 System A p5 System B LPAR A1 LPAR B1 LPAR A2 LPAR B2 LPAR A3 LPAR B3 Figure 2-18 Highly available HMC and network architecture Note that only hardware management networks (LAN1 and LAN2) are highly available on the above picture in order to keep simplicity. However, management network (LAN3) can be made highly available by using a similar concept and adding more Ethernet adapters to LPARs and HMCs. 2.13.2 IBM System Planning Tool The IBM System Planning Tool (SPT) is the next generation of the IBM LPAR Validation Tool (LVT). It contains all of the function from the LVT and is integrated with the IBM Systems Workload Estimator (WLE). System plans generated by the SPT can be deployed on the system by the Hardware Management Console (HMC). The SPT is available to assist the user in system planning, design, validation, and to provide a system validation report that reflects the user’s system requirements while not exceeding system recommendations. The SPT is a PC-based browser application designed to run in a stand-alone environment. The IBM System Planning Tool can be downloaded at no additional charge from: http://www.ibm.com/servers/eserver/support/tools/systemplanningtool/ The System Planning Tool (SPT) helps you design a system to fit your needs. You can use the SPT to design a logically partitioned system or you can use the SPT to design an 62 IBM System p5 520 and 520Q Technical Overview and Introduction unpartitioned system. You can create an entirely new system configuration, or you can create a system configuration based upon any of the following: Performance data from an existing system that the new system is to replace Performance estimates that anticipate future workloads that you must support Sample systems that you can customize to fit your needs Integration between the SPT and both the Workload Estimator (WLE) and IBM Performance Management (PM) allows you to create a system that is based upon performance and capacity data from an existing system or that is based on new workloads that you specify. You can use the SPT before you order a system to determine what you must order to support your workload. You can also use the SPT to determine how you can partition a system that you already have. Important: We recommend using the IBM System Planning Tool to estimate Hypervisor requirements and to determine the memory resources that are required for all partitioned and non-partitioned servers. Figure 2-19 shows the estimated Hypervisor memory requirements based on sample partition requirements. Figure 2-19 IBM System Planning Tool window showing Hypervisor requirements Chapter 2. Architecture and technical overview 63 2.14 Operating system support The p5-520 and p5-520Q are capable of running the AIX 5L and Linux operating systems. The AIX 5L operating system has been developed and enhanced specifically to exploit and to support the extensive RAS features on IBM System p systems. 2.14.1 AIX 5L If you are installing AIX 5L on the server, the following minimum requirements must be met: AIX 5L for POWER V5.2 with the 5200-09 Technology Level (APAR IY82425), or later AIX 5L for POWER V5.3 with the 5300-05 Technology Level (APAR IY82426), or later Note: The Advanced POWER Virtualization feature (FC 7940) is not supported on AIX 5L V5.2. It requires AIX 5L V5.3. IBM periodically releases maintenance packages for the AIX 5L operating system. These packages are available on CD-ROM or you can download them from the Internet at: http://www.ibm.com/servers/eserver/support/unixservers/index.html The Web page provides information about how to obtain the CD-ROM. You can also get individual operating system fixes and information about obtaining AIX 5L service at this Web site. In AIX 5L V5.3, the suma command is also available, which helps the administrator to automate the task of checking and downloading operating system downloads. For more information about the suma command, refer to: http://www14.software.ibm.com/webapp/set2/sas/f/suma/home.html Electronic Software Delivery (ESD) for AIX 5L V5.2 and V5.3 for POWER5 systems was made available. This is a way for clients to receive software and associated publications online, as opposed to waiting for a physical shipment to arrive. Clients requesting ESD should order FC 3450. ESD has the following requirements: POWER5 system Internet connectivity from a POWER5 system or PC and reasonable connection speed for downloading large products such as AIX 5L Registration on the ESD Web site For additional information, contact your IBM marketing representative. Software support for new features in the POWER5+ processor For a complete list of the new features introduced in the POWER5+ processor, see 2.1, “The POWER5+ processor” on page 26. Support for two new virtual memory page sizes was introduced: 64 KB and 16 GB as well as support for 1 TB segment size. While 16 GB pages are intended for use only in very high performance environments, 64 KB pages are general-purpose. AIX 5L Version 5.3 with the 5300-04 Technology Level 64-bit kernel is required for 64 KB and 16 GB page size support. As with all previous versions of AIX, 4 KB is the default page size. A process continues to use 4 KB pages, unless a user specifically requests that another page size is used. AIX 5L has rich support of 64 KB pages. They are easy to use, and we expect that many applications will see performance benefits when using 64 KB pages rather than 4 KB pages. No system 64 IBM System p5 520 and 520Q Technical Overview and Introduction configuration changes are necessary to enable a system to use 64 KB pages; they are fully pageable, and the size of the pool of 64 KB page frames on a system is dynamic and fully managed by AIX 5L. The main benefit of a larger page size is improved performance for applications that allocate and repeatedly access large amounts of memory. The performance improvement from larger page sizes is due to the overhead of translating a page address as it is used in an application, to a page address that is understood by the computer's memory subsystem. To improve performance, the information needed to translate a given page is usually cached in the processor. In POWER5+, this cache takes the form of a translation lookaside buffer (TLB). Because there are a limited number of TLB entries, using a large page size increases the amount of address space that can be accessed without incurring translation delays. Also, the size of TLB in POWER5+ has been doubled compared to POWER5. Huge pages (16 GB) are intended for use only in very high performance environments, and AIX 5L does not automatically configure a system to use these page sizes. A system administrator must configure AIX 5L to use these page sizes and specify their number using an HMC before the partition starts. A user can specify page sizes to use for three regions process' address space with an environment variable or with settings in an application's XCOFF binary using the ldedit or ld commands. These three regions are: data, stack, and program text. An application programmer can also select the page size to use for System V shared memory using a new SHM_PAGESIZE command to the shmctl() system call. The following is an example of using system variables to start a program with 64 KB page size support: LDR_CNTRL=DATAPSIZE=64K@TEXTPSIZE=64K@STACKPSIZE=64K Systems commands (ps, vmstat, svmon, and pagesize) have been enhanced to report various page size usage. 2.14.2 Linux For the p5-520 and p5-520Q, Linux distributions are available through Novell SUSE and Red Hat at the time of writing. The server requires the following version of Linux distributions: SUSE Linux Enterprise Server 9 for POWER Systems or SUSE Linux Enterprise Server 10 for POWER Systems, or later Red Hat Enterprise Linux AS 4 for POWER, or later Note: Not all features available on AIX 5L are available on Linux. IDE VD-ROM/DVD-RAM DLPAR operation is not supported by Red Hat Enterprise Linux AS 4 for POWER. For information about the features and external devices that are supported by Linux, refer to: http://www.ibm.com/systems/p/linux/ For information about SUSE Linux Enterprise Server 9, refer to: http://www.novell.com/products/linuxenterpriseserver/ For information about Red Hat Enterprise Linux AS, refer to: http://www.redhat.com/software/rhel/details/ Chapter 2. Architecture and technical overview 65 Many of the features that are described in this document are operating system dependent and might not be available on Linux. For more information, see: http://www.ibm.com/systems/p/software/whitepapers/linux_overview.pdf Note: IBM only supports the Linux systems of clients with a SupportLine contract that covers Linux. Otherwise, contact the Linux distributor for support. Specially priced Linux subscriptions Linux subscriptions are now available when ordered through IBM and combined with an IBM System p5 Express Product Offering. Clients can purchase a one-year, specially priced subscription or a greater discount for a three-year subscription. These new Linux options, available on IBM System p5 Express Product Offering servers, bring improved pricing and price performance to our clients interested in Linux as their primary operating system. Clients interested in AIX 5L can also obtain an Express Product Offering that fits their needs. Clients are still encouraged to purchase support for their Linux subscription either through IBM Global Services or through the distributor to receive updates and technical assistance as needed. Support is not included in the price of the subscription. The new lower-priced Linux subscriptions, when combined with the lower package prices of the IBM System p5 Express Product Offering, make these products an exceptional value for our smaller to mid-market clients, as well as larger enterprises. Refer to the following Web site for Red Hat information: http://www.redhat.com/software/ For additional information about Linux on POWER, visit: http://www.ibm.com/servers/eserver/linux/power/ 2.15 Service information The p5-520 and p5-520Q are customer setup (CSU) servers and are shipped with materials to assist in the general installation of the server. The server cover has a quick reference service information label that provides graphics that can aid you in identifying features and locating information. This section provides some additional service-related information. 66 IBM System p5 520 and 520Q Technical Overview and Introduction 2.15.1 Touch point colors Blue (IBM blue) or terra-cotta (orange) on a component indicates a touch point (for electronic parts) where you can grip the hardware to remove it from or install it into the system, open or close a latch, and so on. IBM defines the touch point colors as follows: Blue This requires a shutdown of the system, before the task can be performed, for example, installing additional processors contained in the second processor book. Terra-cotta The system can remain powered on while this task is performed. Keep in mind that some tasks might require that you have to perform other steps first. One example is deconfiguring a physical volume in the operating system before removing a disk from a 4-pack disk enclosure of the p5-520 and p5-520Q. Blue and terra-cotta Terra-cotta takes precedence over this color combination, and the rules for a terra-cotta only touch point apply. Important: It is important to adhere to the touch point colors on the system. Not doing so can compromise your safety and damage the system. 2.15.2 Securing a rack-mounted system into a rack The optional rack-mount drawer rail kit is a unique kit designed for use with the rack-mounted model. No tools are required to install the server or drawer rails into the system rack. The kit has a modular design that you can adapt to accommodate various rack depth specifications. The drawer rails are equipped with thumb-releases on the sides, toward the front of the server, that allow for easy slide out from its rack position for servicing. Note: Always exercise standard safety precautions when installing or removing devices from racks. By placing the rack-mounted system or expansion unit in the service position, you can access the inside of the unit. 2.15.3 Placing a rack-mounted system into a rack To place the rack-mounted system or expansion unit into the service position: 1. If necessary, open the front rack door. 2. Remove the two thumbscrews (A) that secure the system or expansion unit (B) to the rack, as shown in the Figure 2-20 on page 68. Chapter 2. Architecture and technical overview 67 Figure 2-20 Pull the server to the service position 3. Release the rack latches (C) on both the left and right sides, as shown in the Figure 2-20. 4. Review the following notes, and then slowly pull the system or expansion unit out from the rack until the rails are fully extended and locked: – If the procedure you are performing requires you to unplug cables from the back of the system or expansion unit, do so before you pull the unit out from the rack. – Ensure that the cables at the rear of the system or expansion unit do not catch or bind as you pull the unit out from the rack. – When the rails are fully extended, the rail safety latches lock into place. This action prevents the system or expansion unit from being pulled out too far. Caution: This unit weighs approximately 43 kg (95 lb.). Ensure that you can safely support this weight when removing the server unit from the system rack. The IBM Systems Hardware Information Center is available for more information or to view available video-clips that describe several of the maintenance repair-action procedures. 2.15.4 Cable-management arm The rack-mounted model is shipped with a cable-management arm to route all the cables through the hooks along the cable arm and secure them with the straps provided. The cable-management arm simplifies the cables management in the case of a service action that requires you to pull out the rack-mounted system from the rack. 68 IBM System p5 520 and 520Q Technical Overview and Introduction 2.15.5 Operator control panel The service processor provides an interface to the control panel that is used to display server status and diagnostic information. See Figure 2-21 for operator control panel physical details and buttons. Figure 2-21 Operator control panel physical details and buttons Note: For servers managed by the HMC, use the HMC to perform control panel functions. Primary control panel functions The primary control panel functions are defined as functions 01 to 20, including options to view and manipulate IPL modes, server operating modes, IPL speed, and IPL type. The following list describes the primary functions: Function 01: Display selected IPL type, system operating mode, and IPL speed Function 02: Select IPL type, IPL speed override, and system operating mode Function 03: Start IPL Function 04: Lamp test Function 05: Reserved Function 06: Reserved Function 07: SPCN functions Function 08: Fast power off Functions 09 to 10: Reserved Functions 11 to 19: System reference code Function 20: System type, model, feature code, and IPL type All the functions mentioned are accessible using the Advanced System Management Interface (ASMI), HMC, or the control panel. Extended control panel functions The extended control panel functions consist of two major groups: Functions 21 through 49, which are available when you select Manual mode from Function 02. Support service representative Functions 50 through 99, which are available when you select Manual mode from Function 02, then select and enter the customer service switch 1 (Function 25), followed by service switch 2 (Function 26). Chapter 2. Architecture and technical overview 69 Function 30 – CEC SP IP address and location Function 30 is one of the Extended control panel functions and is only available when Manual mode is selected. You can use this function to display the central electronic complex (CEC) Service Processor IP address and location segment. Table 2-14 shows an example of how to use Function 30. Table 2-14 CEC SP IP address and location Information on operator panel Action or description 3 0 Use the increment or decrement buttons to scroll to Function 30. 3 0 * * Press Enter to enter sub-function mode. 3 0 0 0 Use the increment or decrement buttons to select an IP address: 0 0 = Service Processor ETH0 or HMC1 port 0 1 = Service Processor ETH1 or HMC2 port S P A: E T H 0: _ _ _ T 5 192.168.2.147 Press Enter to display the selected IP address. 3 0 * * Use the increment or decrement buttons to select sub-function exit. 3 0 Press Enter to exit sub-function mode. 2.15.6 System firmware Server firmware is the part of the Licensed Internal Code that enables hardware, such as the service processor. Depending on your service environment, you can download, install, and manage your server firmware fixes using different interfaces and methods, including the HMC, or by using functions specific to your operating system. See 3.2.4, “IBM System p5 firmware maintenance” on page 87 for a detailed description of IBM System p5 firmware. Note: Normally, installing the server firmware fixes through the operating system is a nonconcurrent process. Temporary and permanent firmware sides The service processor maintains two copies of the server firmware: One copy is considered the permanent or backup copy and is stored on the permanent side, sometimes referred to as the p side. The other copy is considered the installed or temporary copy and is stored on the temporary side, sometimes referred to as the t side. We recommend that you start and run the server from the temporary side. The copy actually booted from is called the activated level, sometimes referred to as b. Note: The default value, from which the system boots, is temporary. 70 IBM System p5 520 and 520Q Technical Overview and Introduction The following examples are the output of the lsmcode command for AIX 5L and Linux, showing the firmware levels as they are displayed in the outputs: AIX 5L The current permanent system firmware image is SF220_005. The current temporary system firmware image is SF220_006. The system is currently booted from the temporary image. Linux system:SF220_006 (t) SF220_005 (p) SF220_006 (b) When you install a server firmware fix, it is installed on the temporary side. Note: The following points are of special interest: The server firmware fix is installed on the temporary side only after the existing contents of the temporary side are permanently installed on the permanent side (the service processor performs this process automatically when you install a server firmware fix). If you want to preserve the contents of the permanent side, you need to remove the current level of firmware (copy the contents of the permanent side to the temporary side) before you install the fix. However, if you get your fixes using the Advanced features on the HMC interface and you indicate that you do not want the service processor to automatically accept the firmware level, the contents of the temporary side are not automatically installed on the permanent side. In this situation, you do not need to remove the current level of firmware to preserve the contents of the permanent side before you install the fix. You might want to use the new level of firmware for a period of time to verify that it works correctly. When you are sure that the new level of firmware works correctly, you can permanently install the server firmware fix. When you permanently install a server firmware fix, you copy the temporary firmware level from the temporary side to the permanent side. Conversely, if you decide that you do not want to keep the new level of server firmware, you can remove the current level of firmware. When you remove the current level of firmware, you copy the firmware level that is currently installed on the permanent side from the permanent side to the temporary side. System firmware download Web site For the system firmware download Web site, go to: http://www14.software.ibm.com/webapp/set2/firmware Chapter 2. Architecture and technical overview 71 Receive server firmware fixes using an HMC If you use an HMC to manage your server and you need to configure several partitions on the server periodically, you need to download and install fixes for your server and power subsystem firmware. How you get the fix depends on whether the HMC or server is connected to the Internet: The HMC or server is connected to the Internet. There are several repository locations from which you can download the fixes using the HMC. For example, you can download the fixes from your service provider's Web site or support system, from optical media that you order from your service provider, or from an FTP server on which you previously placed the fixes. Neither the HMC nor your server is connected to the Internet (server firmware only). You need to download your new server firmware level to a CD-ROM media or FTP server. For both of these two options, you can use the interface on the HMC to install the firmware fix (from one of the repository locations or from the optical media). The Change Internal Code wizard on the HMC provides a step-by-step process for you to perform the procedure to install the fix. Perform these steps: 1. Ensure that you have a connection to the service provider (if you have an Internet connection from the HMC or server). 2. Determine the available levels of server and power subsystem firmware. 3. Create optical media (if you do not have an Internet connection from the HMC or server). 4. Use the Change Internal Code wizard to update your server and power subsystem firmware. 5. Verify that the fix installed successfully. Receive server firmware fixes without an HMC Periodically, you need to install fixes for your server firmware. If you do not use an HMC to manage your server, you must get your fixes through your operating system. In this situation, you can get server firmware fixes through the operating system regardless of whether your operating system is AIX 5L or Linux. To do this, complete the following tasks: 1. 2. 3. 4. 5. 6. 72 Determine the existing level of server firmware using the lsmcode command. Determine the available levels of server firmware. Get the server firmware. Install the server firmware fix to the temporary side. Verify that the server firmware fix installed successfully. Install the server firmware fix permanently (optional). IBM System p5 520 and 520Q Technical Overview and Introduction Note: To view existing levels of server firmware using the lsmcode command, you need to have the following service tools installed on your server: AIX 5L You must have AIX 5L diagnostics installed on your server to perform this task. AIX 5L diagnostics are installed when you install AIX 5L on your server. However, it is possible to deselect the diagnostics. Therefore, you need to ensure that the online AIX 5L diagnostics are installed before proceeding with this task. Linux – Platform Enablement Library: librtas-nnnnn.rpm – Service Aids: ppc64-utils-nnnnn.rpm – Hardware Inventory: lsvpd-nnnnn.rpm Where nnnnn represents a specific version of the RPM file. If you do not have the service tools on your server, you can download them at the following Web site: http://www14.software.ibm.com/webapp/set2/sas/f/lopdiags 2.15.7 Service processor The service processor is an embedded controller running the service processor internal operating system. The service processor operating system contains specific programs and device drivers for the service processor hardware. The host interface is a 32-bit PCI-X interface connected to the Enhanced I/O Controller. The service processor is used to monitor and manage the system hardware resources and devices. The service processor offers two Ethernet 10/100 Mbps ports: Both Ethernet ports are only visible to the service processor and can be used to attach the server to an HMC or to access the Advanced System Management Interface (ASMI) options from a client Web browser, using the http-server integrated into the service processor internal operating system. Both Ethernet ports have a default IP address – Service processor Eth0 or HMC1 port is configured as 192.168.2.147 with netmask 255.255.255.0 – Service processor Eth1 or HMC2 port is configured as 192.168.3.147 with netmask 255.255.255.0 For the major functions of the Service Processor, see 3.2.1, “Service processor” on page 83. 2.15.8 Hardware management user interfaces This section provides a brief overview of the different hardware management user interfaces available. Advanced System Management Interface The Advanced System Management Interface (ASMI) is the interface to the service processor that enables you to set flags that affect the operation of the server, such as auto power restart, and to view information about the server, such as the error log and vital product data. Chapter 2. Architecture and technical overview 73 This interface is accessible using a Web browser on a client system that is connected directly to the service processor (in this case, you can use either a standard Ethernet cable or a crossed cable) or through an Ethernet network. Using the network configuration menu, the ASMI enables the possibility to change the service processor IP addresses or to apply some security policies and avoid access from undesired IP addresses or ranges. You can also access the ASMI using a terminal attached to the system service processor ports on the server, if the server is not HMC-managed. The service processor and the ASMI are standard on all IBM System p servers. You might be able to use the service processor's default settings. In that case, accessing the ASMI is not necessary. Accessing the ASMI using a Web browser The Web interface to the Advanced System Management Interface is accessible through, at the time of writing, Microsoft® Internet Explorer® 6.0, Netscape 7.1, Mozilla Firefox, or Opera 7.23 running on a PC or mobile computer connected to the service processor. The Web interface is available during all phases of system operation including the initial program load and run time. However, some of the menu options in the Web interface are unavailable during IPL or run time to prevent usage or ownership conflicts if the system resources are in use during that phase. Accessing the ASMI using an ASCII console The Advanced System Management Interface on an ASCII console supports a subset of the functions provided by the Web interface and is available only when the system is in the platform standby state. The ASMI on an ASCII console is not available during some phases of system operation, such as the initial program load and run time. Accessing the ASMI using an HMC To access the Advanced System Management Interface using the Hardware Management Console, complete the following steps: 1. Ensure that the HMC is set up and configured. 2. In the navigation area, expand the managed system with which you want to work. 3. Expand Service Applications and click Service Focal Point. 4. In the content area, click Service Utilities. 5. From the Service Utilities window, select the managed system with which you want to work. 6. From the Selected menu on the Service Utilities window, select Launch ASM. System Management Services Use the System Management Services (SMS) menus to view information about your system or partition and to perform tasks such as changing the boot list or setting the network parameters. To start System Management Services, perform the following steps: 1. For a server that is connected to an HMC, use the HMC to restart the server or partition. If the server is not connected to an HMC, stop the system, and then restart the server by pressing the power button on the control panel. 2. For a partitioned server, watch the virtual terminal window on the HMC. For a full server partition, watch the firmware console. 74 IBM System p5 520 and 520Q Technical Overview and Introduction 3. Look for the power-on self-test (POST) indicators: memory, keyboard, network, SCSI, and speaker that appear across the bottom of the screen. Press the numeric 1 key after the word keyboard appears and before the word speaker appears. The SMS menus are useful to define the operating system installation method, choosing the installation boot device, or setting the boot device priority list for a fully managed server or a logical partition. In the case of a network boot, SMS menus are provided to set up the network parameters and network adapter IP address. HMC The Hardware Management Console is a system that controls managed systems, including IBM System p5 hardware, logical partitions, and Capacity on Demand. To provide flexibility and availability, there are different ways to implement HMCs, including a local HMC, remote HMC, redundant HMC, and the Web-based System Manager Remote Client. Local HMC A local HMC is any physical HMC that is directly connected to the server that it manages through a private service network. An HMC in a private service network can be a Dynamic Host Control Protocol (DHCP) server from which the managed server obtains the address for its firmware. Additional local HMCs in your private service network cannot be other DHCP servers, but they can be DHCP clients. Remote HMC A remote HMC is a stand-alone HMC or an HMC installed in a rack that is used to access another HMC remotely. A remote HMC can be present in an open network. Redundant HMC A redundant HMC manages a server that is already managed by another HMC. When two HMCs manage one server, those HMCs are peers and can be used simultaneously to manage the server. The redundant HMC in your private service network is usually a DHCP client. Web-based System Manager Remote Client The Web-based System Manager Remote Client is an application that you typically installed on a PC and you can download directly from an installed HMC. After you have installed an HMC, and you have assigned HMC Ethernet IP addresses, you can download the Web-based System Manager Remote Client from a Web browser, using the following URL: http://HMC_IP_address/remote_client.html You can then use the PC to access other HMCs remotely. Web-based System Manager Remote Clients can be present in private and open networks. You can perform most management tasks using the Web-based System Manager Remote Client. The remote HMC and the Web-based System Manager Remote Client allow you the flexibility to access your managed systems (including HMCs) from multiple locations using multiple HMCs. For more detailed information about the use of the HMC, refer to the IBM Systems Hardware Information Center. Open Firmware An IBM System p5 server has one instance of Open Firmware both when used in the partitioned environment and when running as a full system partition. Open Firmware has access to all devices and data in the server. Open Firmware is started when the server goes Chapter 2. Architecture and technical overview 75 through a power-on reset. Open Firmware, which runs in addition to the Hypervisor in a partitioned environment, runs in two modes: global and partition. Each mode of Open Firmware shares the same firmware binary that is stored in the flash memory. In a partitioned environment, Open Firmware runs on top of the global Open Firmware instance. The partition Open Firmware is started when a partition is activated. Each partition has its own instance of Open Firmware and has access to all the devices assigned to that partition. However, each instance of Open Firmware has no access to devices outside of the partition in which it runs. Partition firmware resides within the partition memory and is replaced when AIX 5L or Linux takes control. Partition firmware is needed only for the time that is necessary to load AIX 5L or Linux into the partition server memory. The global Open Firmware environment includes the partition manager component. That component is an application in the global Open Firmware that establishes partitions and their corresponding resources (such as CPU, memory, and I/O slots), which are defined in partition profiles. The partition manager manages the operational partitioning transactions. It responds to commands from the service processor external command interface that originates in the application running on the HMC. The ASMI can be accessed during boot time or by using the ASMI and selecting the boot to Open Firmware prompt. For more information about Open Firmware, refer to Partitioning Implementations for IBM Sserver p5 Servers, SG24-7039, at: http://www.redbooks.ibm.com/abstracts/sg247039.html 76 IBM System p5 520 and 520Q Technical Overview and Introduction 3 Chapter 3. RAS and manageability This chapter provides information about IBM System p5 design features that help lower the total cost of ownership (TCO). IBM reliability, availability, and service (RAS) technology allow you to improve your TCO architecture by reducing unplanned down time. This chapter includes several features based on the benefits that are available when you use AIX 5L. Support of these features using Linux can vary. © Copyright IBM Corp. 2006. All rights reserved. 77 3.1 Reliability, availability, and serviceability Excellent quality and reliability are inherent in all aspects of the IBM System p5 processor design and manufacturing. The fundamental objective of the design approach is to minimize outages. The RAS features help to ensure that the system operates when required, performs reliably, and efficiently handles any failures that might occur. This is achieved using capabilities that both the hardware and the operating system AIX 5L provide. The p5-520 or p5-520Q as a POWER5+ server enhances the RAS capabilities that are implemented in POWER4-based systems. RAS enhancements available on POWER5 and POWER5+ servers are: Most firmware updates allow the system to remain operational. The ECC has been extended to inter-chip connections for the fabric and processor bus. Partial L2 cache deallocation is possible. The number of L3 cache line deletes improved from two to ten for better self-healing capability. The following sections describe the concepts that form the basis of leadership RAS features of IBM System p5 systems in more detail. 3.1.1 Fault avoidance IBM System p5 servers are built on a quality-based design that is intended to keep errors from happening. This design includes the following features: Reduced power consumption and cooler operating temperatures for increased reliability, which is enabled by the use of copper circuitry, silicon-on-insulator, and dynamic clock gating Mainframe-inspired components and technologies 3.1.2 First-failure data capture If a problem should occur, the ability to diagnose that problem correctly is a fundamental requirement upon which improved availability is based. The p5-520 and p5-520Q incorporate advanced capability in start-up diagnostics and in run-time First-failure data capture (FDDC) based on strategic error checkers built into the processors. Any errors detected by the pervasive error checkers are captured into Fault Isolation Registers (FIRs), which can be interrogated by the service processor. The service processor has the capability to access system components using special purpose ports or by access to the error registers. Figure 3-1 on page 79 shows a schematic of a Fault Register Implementation. 78 IBM System p5 520 and 520Q Technical Overview and Introduction Error Checkers CPU Fault Isolation Register (FIR) (unique fingerprint of each error captured) L1 Cache L2/L3 Cache Service Processor Log Error Memory Non-volatile RAM Disk Figure 3-1 Schematic of Fault Isolation Register implementation The FIRs are important because they enable an error to be uniquely identified, thus enabling the appropriate action to be taken. Appropriate actions might include such things as a bus retry, ECC correction, or system firmware recovery routines. Recovery routines can include dynamic deallocation of potentially failing components. Errors are logged into the system non-volatile random access memory (NVRAM) and the service processor event history log, along with a notification of the event to AIX 5L for capture in the operating system error log. Diagnostic Error Log Analysis (diagela) routines analyze the error log entries and invoke a suitable action such as issuing a warning message. If the error can be recovered, or after suitable maintenance, the service processor resets the FIRs so that they can record any future errors accurately. The ability to correctly diagnose any pending or firm errors is a key requirement before any dynamic or persistent component deallocation or any other reconfiguration can take place. For further details, see 3.1.7, “Resource deallocation” on page 81. 3.1.3 Permanent monitoring The service processor (SP) included in the p5-520 or p5-520Q provides a way to monitor the system even when the main processor is inoperable. Mutual surveillance The SP can monitor the operation of the firmware during the boot process, and it can monitor the operating system for loss of control. This allows the service processor to take appropriate action, including calling for service, when it detects that the firmware or the operating system has lost control. Mutual surveillance also allows the operating system to monitor for service processor activity and can request a service processor repair action if necessary. Environmental monitoring Environmental monitoring related to power, fans, and temperature is done by the System Power Control Network (SPCN). Environmental critical and non-critical conditions generate Early Power-Off Warning (EPOW) events. Critical events (for example, Class 5 ac power loss) trigger appropriate signals from the hardware to the impacted components in order to prevent any data loss without the operating system or firmware involvement. Non-critical environmental events are logged and reported using Event Scan. Chapter 3. RAS and manageability 79 The operating system cannot program or access the temperature threshold using the SP. EPOW events can, for example, trigger the following actions: Temperature monitoring, which increases the fan’s rotation speed when ambient temperature is above a preset operating range. Temperature monitoring warns the system administrator of potential environment-related problems. It also performs an orderly system shutdown when the operating temperature exceeds a critical level. Voltage monitoring provides warning and an orderly system shutdown when the voltage is out of the operational specification. 3.1.4 Self-healing For a system to be self-healing, it must be able to recover from a failing component by first detecting and isolating the failed component, taking it offline, fixing or isolating it, and reintroducing the fixed or replacement component into service without any application disruption. Examples include: Bit steering to redundant memory in the event of a failed memory module to keep the server operational Bit-scattering, thus allowing for error correction and continued operation in the presence of a complete chip failure (Chipkill™ recovery) Single bit error correction using ECC without reaching error thresholds for main, L2, and L3 cache memory L3 cache line deletes extended from 2 to 10 for additional self-healing ECC extended to inter-chip connections on fabric and processor bus Memory scrubbing to help prevent soft-error memory faults Memory reliability, fault tolerance, and integrity The p5-520 and p5-520Q use Error Checking and Correcting (ECC) circuitry for system memory to correct single-bit and to detect double-bit memory failures. Detection of double-bit memory failures helps maintain data integrity. Furthermore, the memory chips are organized such that the failure of any specific memory module only affects a single bit within a four-bit ECC word (bit-scattering), thus allowing for error correction and continued operation in the presence of a complete chip failure (Chipkill recovery). The memory DIMMs also use memory scrubbing and thresholding to determine when spare memory modules within each bank of memory should be used to replace memory modules that have exceeded their threshold of error count (dynamic bit-steering). Memory scrubbing is the process of reading the contents of the memory during idle time and checking and correcting any single-bit errors that have accumulated by passing the data through the ECC logic. This function is a hardware function on the memory controller and does not influence normal system memory performance. 80 IBM System p5 520 and 520Q Technical Overview and Introduction 3.1.5 N+1 redundancy The use of redundant parts allows the p5-520 and p5-520Q to remain operational with full resources: Redundant spare memory bits in L1, L2, L3, and main memory Redundant fans Redundant power supplies (optional) Note: With this optional feature, every deskside or rack-mounted p5-520 or p5-520Q requires two power cords, which are not included in the base order. For maximum availability, we highly recommend that you connect power cords from the same p5-520 or p5-520Q to two separate PDUs in the rack, which are connected to two independent client power sources. For a deskside p5-520 or p5-520Q, you need to plug power cords to two independent power sources in order to achieve maximum availability. 3.1.6 Fault masking If corrections and retries succeed and do not exceed threshold limits, the system remains operational with full resources, and no intervention is required: CEC bus retry and recovery PCI-X bus recovery ECC Chipkill soft error 3.1.7 Resource deallocation If recoverable errors exceed threshold limits, resources can be deallocated with the system remaining operational, allowing deferred maintenance at a convenient time. Dynamic or persistent deallocation Dynamic deallocation of potentially failing components is nondisruptive, allowing the system to continue to run. Persistent deallocation occurs when a failed component is detected, which is then deactivated at a subsequent reboot. Dynamic deallocation functions include: Processor L3 cache line delete Partial L2 cache deallocation PCI-X bus and slots For dynamic processor deallocation, the service processor performs a predictive failure analysis based on any recoverable processor errors that have been recorded. If these transient errors exceed a defined threshold, the event is logged and the processor is deallocated from the system while the operating system continues to run. This feature (named CPU Guard) enables maintenance to be deferred until a suitable time. Processor deallocation can only occur if there are sufficient functional processors (at least two). To verify whether CPU Guard has been enabled, run the following command: lsattr -El sys0 | grep cpuguard If enabled, the output is similar to the following: cpuguard enable CPU Guard True Chapter 3. RAS and manageability 81 If the output shows CPU Guard as disabled, enter the following command to enable it: chdev -l sys0 -a cpuguard='enable' Cache or cache-line deallocation is aimed at performing dynamic reconfiguration to bypass potentially failing components. This capability is provided for both L2 and L3 caches. Dynamic run-time deconfiguration is provided if a threshold of L1 or L2 recovered errors is exceeded. In the case of an L3 cache run-time array single-bit solid error, the spare resources are used to perform a line delete on the failing line. PCI hot-plug slot fault tracking helps prevent slot errors from causing a system machine check interrupt and subsequent reboot. This provides superior fault isolation, and the error affects only the single adapter. Run-time errors on the PCI bus caused by failing adapters result in recovery action. If this is unsuccessful, the PCI device is shut down gracefully. Parity errors on the PCI bus itself result in bus retry, and if uncorrected, the bus and any I/O adapters or devices on that bus are deconfigured. The p5-520 or p5-520Q supports PCI Extended Error Handling (EEH), if it is supported by the PCI-X adapter. In the past, PCI bus parity errors caused a global machine check interrupt, which eventually required a system reboot in order to continue. In the p5-520 or p5-520Q system, hardware, system firmware, and AIX 5L interaction have been designed to allow transparent recovery of intermittent PCI bus parity errors and graceful transition to the I/O device available state in the case of a permanent parity error in the PCI bus. EEH-enabled adapters respond to a special data packet generated from the affected PCI slot hardware by calling system firmware, which examines the affected bus, allows the device driver to reset it, and continues without a system reboot. Persistent deallocation functions include: Processor Memory Deconfigure or bypass failing I/O adapters L3 cache Following a hardware error that has been flagged by the service processor, the subsequent reboot of the system invokes extended diagnostics. If a processor or L3 cache is marked for deconfiguration by persistent processor deallocation, the boot process attempts to proceed to completion with the faulty device deconfigured automatically. Failing I/O adapters are deconfigured or bypassed during the boot process. Note: The auto-restart (reboot) option, when enabled, can reboot the system automatically following an unrecoverable software error, software hang, hardware failure, or environmentally induced failure (such as a loss of the power supply). 3.1.8 Serviceability Increasing service productivity means the system is up and running for a longer time. The p5-520 and p5-520Q improve service productivity by providing the functions described in the following sections. Error indication and LED indicators The p5-520 and p5-520Q are designed for client setup of the machine and for the subsequent addition of most hardware features. The p5-520 and p5-520Q also allow clients to replace service parts (Client Replaceable Unit). To accomplish this, the p5-520 or p5-520Q provides 82 IBM System p5 520 and 520Q Technical Overview and Introduction internal LED diagnostics that identify the parts that require service. Attenuation of the error is provided through a series of light attention signals, starting on the exterior of the system (System Attention LED) which is located on the front of the system and ending with an LED near the failing Field Replaceable Unit. For more information about Client Replaceable Units, including videos, see: http://publib.boulder.ibm.com/eserver System attention LED The attention indicator is represented externally by an amber LED on the operator panel and on the back of the system unit. The amber LED indicates that the system is in one of the following states: Normal state, LED is off. Fault state, LED is on solid. Identify state, LED is blinking. Additional LEDs on I/O components such as PCI-X slots and disk drives provide status information such as power, hot-swap, and need for service. Concurrent maintenance Concurrent Maintenance provides replacement of the following parts while the system remains running: Disk drives Cooling fans Power subsystems PCI-X adapter cards Operator Panel (requires HMC-guided support) GX RIO-2/HSL-2 Adapter (FC 2888) – All PCI-X adapters connected to the involved RIO loop must be first varied offline from the operating system. – This concurrent maintenance task requires HMC-guided support. 3.2 Manageability We describe the functions and tools provided for IBM System p5 servers to ease management in the next sections. 3.2.1 Service processor The service processor (SP) is always working. CEC can be in the following states: Power standby mode (power off) Operating, ready to start partitions Operating with some partitions running and an AIX 5L or Linux system in control of the machine. The SP is still working and checking the system for errors, ensuring the connection to the HMC (if present) for manageability purposes and accepting Advanced System Management Interface (ASMI) SSL network connections. The SP provides the capability to view and Chapter 3. RAS and manageability 83 manage the machine-wide settings using the ASMI and allows complete system and partition management from the HMC. Also, the surveillance function of the SP is monitoring the operating system to check that it is still running and has not stalled. Note: The IBM System p5 service processor enables the analysis of a system that does not boot. It can be performed either from ASMI, an HMC, or an ASCI console (depending on the presence of an HMC). ASMI is provided in any case. Figure 3-2 shows an example of the ASMI accessed from a Web browser. Figure 3-2 Advanced System Management main menu 3.2.2 Partition diagnostics The diagnostics consist of stand-alone diagnostics, which are loaded from the DVD-ROM drive, and online diagnostics (available in AIX 5L): Online diagnostics, when installed, are resident with AIX 5L on the disk or server. They can be booted in single-user mode (service mode), run in maintenance mode, or run concurrently (concurrent mode) with other applications. They have access to the AIX 5L error log and the AIX 5L configuration data: – Service mode (requires service mode boot) enables you to check system devices and features. Service mode provides the most complete checkout of the system resources. All system resources, except the SCSI adapter and the disk drives used for paging, can be tested. 84 IBM System p5 520 and 520Q Technical Overview and Introduction – Concurrent mode enables the normal system functions to continue while you are checking selected resources. Because the system is running in normal operation, some devices might require additional actions by the user or diagnostic application before testing can be done. – Maintenance mode enables checking of most system resources. Maintenance mode provides the exact same test coverage as Service Mode. The difference between the two modes is the way you invoke them. Maintenance mode requires that all activity on the operating system is stopped. You use the shutdown -m command to stop all activity on the operating system and put the operating system into maintenance mode. The System Management Services (SMS) error log is accessible from the SMS menu for tests performed through SMS programs. For results of service processor tests, access the error log from the service processor menu. Note: Because the p5-520 and p5-520Q system have an optional DVD-ROM (FC 1994) and DVD-RAM (FC 1993), alternate methods for maintaining and servicing the system need to be available if you do not order the DVD-ROM or DVD-RAM. You can also use the Network Install Manager (NIM) server for this purpose. 3.2.3 Service Agent Service Agent is an application program that operates on an IBM System p server and monitors the server for hardware errors. It reports detected errors, assuming they meet certain criteria for severity, to IBM for service with no intervention. It is an enhanced version of Service Director™ with a graphical user interface. Key things you can accomplish using Service Agent for the IBM System p5, pSeries, and RS/6000 include: Automatic VPD collection Automatic problem analysis Problem-definable threshold levels for error reporting Automatic problem reporting where service calls are placed to IBM without intervention Automatic client notification In addition, there are: Commonly viewed hardware errors. You can view hardware event logs for any monitored machine in the network from any Service Agent host user interface. High-availability cluster multiprocessing (HACMP) support for full fallback. Network environment support with minimum telephone lines for modems. A communication base is provided for performance data collection and reporting tool Performance Management (PM/AIX). For more information about PM/AIX, see: http://www.ibm.com/servers/aix/pmaix.html You use the Service Agent user interface to define machines. After you define the machines, they are registered with the IBM Service Agent Server (SAS). During the registration process, an electronic key is created that becomes part of your resident Service Agent program. This key is used each time the Service Agent places a call for service. The IBM Service Agent Server checks the current client service status from the IBM entitlement database. If this reveals that you are not on Warranty or MA, the service call is refused and a message is posted back using an e-mail notification. You can connect Service Agent to connect to IBM either using a modem or a network connection. In any case, the communication is encrypted and strong authentication is used. Chapter 3. RAS and manageability 85 Service Agent sends outbound transmissions only and does not allow any inbound connection attempts. Only hardware machine configuration, machine status, or error information is transmitted. Service Agent does not access or transmit any other data on the monitored systems. Three principal ways of communication are possible: Dial-up using an attached modem device (uses the AT&T Global Network dialer for modem access; it does not accept incoming calls to the modem) VPN (IPsec is used in this case) HTTPS (can be configured to work with firewalls and authenticating proxies) Figure 3-3 shows possible communication paths for an IBM System p5 server that is configured to use all the features of Service Agent. In this figure, communication to IBM support can be through either a modem or the network. If an HMC is present, Service Agent is an integral part of the HMC and, if activated, collects hardware-related information and error messages about the entire system and partitions. If software level information (such as performance data) is also required, you can also install Service Agent on any of the partitions and configure Service Agent to act as either a gateway and a connection manager or as a client. When you configure Service Agent as a gateway and a connection manager, it gathers data from clients and communicates to IBM on behalf of them. Figure 3-3 Service Agent and possible connections to IBM Service Agent provides these additional services: My Systems: Client and IBM employees authorized by the client can view hardware and software information and error messages that are gathered by Service Agent on Electronic Services WWW pages at: http://www.ibm.com/support/electronic Premium Search: A search service using information gathered by Service Agents (this is a paid service that requires a special contract). Performance Management: Service Agent provides the means for collecting long-term performance data. The data is collected in reports accessed by the client on WWW pages of Electronic Services (this is a paid service that requires a special contract). 86 IBM System p5 520 and 520Q Technical Overview and Introduction You can download the latest version of Service Agent at: ftp://ftp.software.ibm.com/aix/service_agent_code Service Focal Point Traditional service strategies become more complicated in a partitioned environment. Each logical partition reports errors it detects, without determining if other logical partitions also detect and report the errors. For example, if one logical partition reports an error for a shared resource, such as a managed system power supply, other active logical partitions might report the same error. The Service Focal Point application helps you to avoid long lists of repetitive call-home information by recognizing that these are repeated or duplicate errors and correlating them into one error. Service Focal Point is an application on the HMC that enables you to diagnose and repair problems on the system. In addition, you can use Service Focal Point to initiate service functions on systems and logical partitions that are not associated with a particular problem. You can configure the HMC to use the Service Agent call-home feature to send IBM event information. Service Focal Point is available also in Integrated Virtualization Manager. It allows you to manage serviceable events, create serviceable events, manage dumps, and collect vital product data (VPD), but no reporting through Service Agent is possible. 3.2.4 IBM System p5 firmware maintenance The IBM System p5, pSeries, and RS/6000 Client-Managed Microcode is a methodology that enables you to manage and install microcode updates on IBM System p5, pSeries, and RS/6000 systems and associated I/O adapters. The IBM System p5 microcode can be installed either from an HMC or from a running partition. For update details, see 2.15.6, “System firmware” on page 70. If you use an HMC to manage your server, you can use the HMC interface to view the levels of server firmware and power subsystem firmware that are installed on your server and are available to download and install. Each IBM System p5 server has the following levels of server firmware and power subsystem firmware: Installed level – This is the level of server firmware or power subsystem firmware that has been installed and will be installed into memory after the managed system is powered off and powered on. It is installed on the t side of system firmware. For additional discussion about firmware sides, see 2.15.7, “Service processor” on page 73. Activated level – This is the level of server firmware or power subsystem firmware that is active and running in memory. Accepted level – This is the backup level of server or power subsystem firmware. You can return to this level of server or power subsystem firmware if you decide to remove the installed level. It is installed on the p side of system firmware. For additional discussion about firmware sides, see 2.15.7, “Service processor” on page 73. IBM introduced the Concurrent Firmware Maintenance (CFM) function on System p5 systems in system firmware level 01SF230_126_120, which was released on 16 June 2005. This function supports applying nondisruptive system firmware service packs to the system concurrently (without requiring a reboot to activate changes). For systems that are not managed by an HMC, the installation of system firmware is always disruptive. The concurrent levels of system firmware can, on occasion, contain fixes that are known as deferred. These deferred fixes can be installed concurrently but are not activated until the next IPL. For deferred fixes within a service pack, only the fixes in the service pack, which Chapter 3. RAS and manageability 87 cannot be concurrently activated, are deferred. Figure 3-4 shows the system firmware file naming convention. Firmware Release level Last disruptive Firmware Service Pack level 01SFXXX_YYY_ZZZ Firmware Service Pack level Figure 3-4 System firmware file naming convention An installation is disruptive if: The release levels (XXX) of currently installed and new firmware are different. The service pack level (YYY) and the last disruptive service pack level (ZZZ) are equal in new firmware. Otherwise, an installation is concurrent if: The service pack level (YYY) of the new firmware is higher than the service pack level currently installed on the system and the above conditions for disruptive installation are not met. 3.3 Cluster solution Today's IT infrastructure requires that servers meet increasing demands, while offering the flexibility and manageability to rapidly develop and deploy new services. IBM clustering hardware and software provide the building blocks, with availability, scalability, security, and single-point-of-management control, to satisfy these needs. The advantages of clusters are: Large-capacity data and transaction volumes, including support of mixed workloads Scale-up (add processors) or scale-out (add servers) without down time Single point-of-control for distributed and clustered server management Simplified use of IT resources Designed for 24x7 access to data applications Business continuity in the event of a disaster The POWER processor-based AIX 5L and Linux cluster target scientific and technical computing, large-scale databases, and workload consolidation. IBM Cluster Systems Management software (CSM) is designed to provide a robust, powerful, and centralized way to manage a large number of POWER5 processor-based servers, all from a single point-of-control. Cluster Systems Management can help lower the overall cost of IT ownership by helping to simplify the tasks of installing, operating, and maintaining clusters of servers. Cluster Systems Management can provide one consistent interface for managing both AIX 5L and Linux nodes (physical systems or logical partitions), with capabilities for remote parallel network installation, remote hardware control, and distributed command execution. Cluster Systems Management for AIX 5L and Linux on POWER processor-based servers is supported on the p5-520 and the p5-520Q servers. For hardware control, an HMC is required. One HMC can also control several IBM System p5 servers that are part of the 88 IBM System p5 520 and 520Q Technical Overview and Introduction cluster. If a server that is configured in partition mode (with physical or virtual resources) is part of the cluster, all partitions must be part of the cluster. Monitoring is much easier to use, and the system administrator can monitor all of the network interfaces, not just the switch and administrative interfaces. The management server pushes information out to the nodes, which releases the management server from having to trust the node. In addition, the nodes do not have to be network-connected to each other. This means that giving root access on one node does not mean giving root access on all nodes. The base security setup is all performed automatically at installation time. For information regarding the IBM Cluster Systems Management for AIX 5L, HMC control, cluster building block servers, and cluster software available, visit the following links: Cluster 1600 http://www.ibm.com/servers/eserver/clusters/hardware/1600.html Cluster 1350™ http://www.ibm.com/systems/clusters/hardware/1350.html The CSM ships with AIX 5L itself (a 60-day Try and Buy license ships with AIX). The CSM client side is installed automatically and is ready when you install AIX 5L. So, each system or logical partition is cluster-ready. The CSM V1.5 on AIX 5L and Linux introduces an optional IBM CSM High Availability Management Server feature, which is designed to allow automated failover of the CSM management server to a backup management server. In addition, sample scripts for setting up Network Time Protocol (NTP), and network tuning (AIX 5L only) configurations, and the capability to copy files across nodes or node groups in the cluster can improve cluster ease of use and site customization. Chapter 3. RAS and manageability 89 90 IBM System p5 520 and 520Q Technical Overview and Introduction Related publications The publications listed in this section are considered particularly suitable for a more detailed discussion of the topics that are covered in this Redpaper. IBM Redbooks For information about ordering these publications, see “How to get IBM Redbooks” on page 93. Note that some of the documents that are referenced here might be available in softcopy only. Advanced POWER Virtualization on IBM System p5, SG24-7940 Partitioning Implementations for IBM Eserver p5 Servers, SG24-7039 Advanced POWER Virtualization on IBM Eserver p5 Servers: Architecture and Performance Considerations, SG24-5768 IBM Eserver pSeries Sizing and Capacity Planning: A Practical Guide, SG24-7071 Problem Solving and Troubleshooting in AIX 5L, SG24-5496 IBM Eserver p5 590 and 595 System Handbook, SG24-9119 LPAR Simplification Tools Handbook, SG24-7231 Virtual I/O Server Integrated Virtualization Manager, REDP-4061 IBM Eserver p5 590 and 595 Technical Overview and Introduction, REDP-4024 IBM Eserver p5 510 Technical Overview and Introduction, REDP-4001 IBM Eserver p5 520 Technical Overview and Introduction, REDP-9111 IBM Eserver p5 550 Technical Overview and Introduction, REDP-9113 IBM Eserver p5 570 Technical Overview and Introduction, REDP-9117 IBM System p5 505 Express Technical Overview and Introduction, REDP-4079 IBM System p5 510 and 510Q Technical Overview and Introduction, REDP-4136 IBM System p5 550 and 550Q Technical Overview and Introduction, REDP-4138 IBM System p5 560Q Technical Overview and Introduction, REDP-4139 Hardware Management Console (HMC) Case Configuration Study for LPAR Management, REDP-3999 Other publications These publications are also relevant as further information sources: 7014 Series Model T00 and T42 Rack Installation and Service Guide, SA38-0577, contains information regarding the 7014 Model T00 and T42 Rack, in which you can install this server. 7316-TF3 17-Inch Flat Panel Rack-Mounted Monitor and Keyboard Installation and Maintenance Guide, SA38-0643, contains information regarding the 7316-TF3 Flat Panel Display, which you can install in your rack to manage your system units. © Copyright IBM Corp. 2006. All rights reserved. 91 IBM Sserver Hardware Management Console for pSeries Installation and Operations Guide, SA38-0590, provides information to operators and system administrators about how to use a IBM Hardware Management Console for pSeries (HMC) to manage a system. It also discusses the issues associated with logical partitioning planning and implementation. Planning for Partitioned-System Operations, SA38-0626, provides information to planners, system administrators, and operators about how to plan for installing and using a partitioned server. It also discusses some issues associated with planning and implementing partitioning. RS/6000 and Sserver pSeries Diagnostics Information for Multiple Bus Systems, SA38-0509, contains diagnostic information, service request numbers (SRNs), and failing function codes (FFCs). System p5, Server p5 Customer service support and troubleshooting, SA38-0538, contains information regarding slot restrictions for adapters that you can use in this system. System Unit Safety Information, SA23-2652, contains translations of safety information used throughout the system documentation. Online resources These Web sites and URLs are also relevant as further information sources: AIX 5L operating system maintenance packages downloads http://www.ibm.com/servers/eserver/support/unixservers/aixfixes.html News on new computer technologies http://www.ibm.com/chips/micronews Copper circuitry http://domino.research.ibm.com/comm/pr.nsf/pages/rsc.copper.html IBM Systems Hardware Information Center documentation http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp IBM Systems Information Centers http://publib.boulder.ibm.com/eserver/ IBM microcode downloads http://www14.software.ibm.com/webapp/set2/firmware/gjsn Support for IBM System p servers http://www.ibm.com/servers/eserver/support/unixservers/index.html Technical help database for AIX 5L http://www14.software.ibm.com/webapp/set2/srchBroker/views/srchBroker.jsp?rs=111 IBMlink http://www.ibmlink.ibm.com Linux for IBM System p5 http://www.ibm.com/systems/p/linux/ Microcode Discovery Service http://www14.software.ibm.com/webapp/set2/mds/fetch?page=mds.html 92 IBM System p5 520 and 520Q Technical Overview and Introduction How to get IBM Redbooks You can search for, view, or download Redbooks, Redpapers, Hints and Tips, draft publications and Additional materials, as well as order hardcopy Redbooks or CD-ROMs, at this Web site: ibm.com/redbooks Help from IBM IBM Support and downloads ibm.com/support IBM Global Services ibm.com/services Related publications 93 94 IBM System p5 520 and 520Q Technical Overview and Introduction Back cover ® IBM System p5 520 and 520Q Technical Overview and Introduction Finer system granulation using Micro-Partitioning technology to help lower TCO Support for versions of AIX 5L and Linux operating systems From Web servers to integrated cluster solutions This IBM Redpaper is a comprehensive guide that covers the IBM System p5 520 and 520Q UNIX servers. It introduces major hardware offerings and discusses their prominent functions. Professionals who want to acquire a better understanding of IBM System p products should read this document. The intended audience includes: • • • • • Clients Marketing representatives Technical support professionals IBM Business Partners Independent software vendors This document expands the current set of IBM System p documentation and provides a desktop reference that offers a detailed technical description of the IBM System p5 520 and the p5 520Q servers. This publication does not replace the latest IBM System p marketing materials and tools. It is intended as an additional source of information that you can use, together with existing sources, to enhance your knowledge of IBM server solutions. Redpaper INTERNATIONAL TECHNICAL SUPPORT ORGANIZATION BUILDING TECHNICAL INFORMATION BASED ON PRACTICAL EXPERIENCE IBM Redbooks are developed by the IBM International Technical Support Organization. Experts from IBM, Customers and Partners from around the world create timely technical information based on realistic scenarios. Specific recommendations are provided to help you implement IT solutions more effectively in your environment. For more information: ibm.com/redbooks
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Tagged PDF : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Keywords : www.gstinc.com; http://www.gstinc.com; gstinc.com; GST Inc; GST; David Breisacher; Breisacher; zSeries; z9; z/VSE; z/VM; z/OS; xSeries; Windows Server; Windows NT; Windows; WebSphere 1350; WebSphere; Virtualization Engine; UNIX; Universal Database DB2; Trackpoint; TotalStorage; Tivoli; System/38; System/36; System z; System x; System Storage; System p5; System p; System i5; System i; Sysplex; Sun Solaris; StorageTek; Solaris; Service Director; ServerProven; ServeRAID; SecureWay; Seascape; S/390; RSM; RS/6000; RPG/400; RISC System/6000; replace tape drive; replace system; replace server; replace scsi adapter; replace RAM; replace raid enablement card; replace raid enablement adapter; replace raid enablement; replace raid disk controller; replace raid adapter; replace processor; replace power supply; replace memory module; replace memory; replace iscsi adapter; replace infiniband adapter; replace graphics adapter; replace fibre adapter; replace expansion unit; replace ethernet adapter; replace dvd; replace display; replace disk drive; replace disk; replace DASD; replace cable assembly; replace async adapter; remove tape drive; remove system; remove server; remove scsi adapter; remove RAM; remove raid enablement card; remove raid enablement adapter; remove raid enablement; remove raid disk controller; remove raid adapter; remove processor; remove power supply; remove memory module; remove memory; remove iscsi adapter; remove infiniband adapter; remove graphics adapter; remove fibre adapter; remove expansion unit; remove ethernet adapter; remove dvd; remove display; remove disk drive; remove disk; remove DASD; remove cable assembly; remove async adapter; Redbooks; PTX; pSeries; Predictive Failure Analysis; POWERserver; PowerPC Architecture; PowerPC 750; PowerPC; PowerExecutive; POWER6; POWER5+; POWER5; POWER4; POWER3; POWER2; Power Series; Power PC; Power Management; POWER Hypervisor; Power Architecture; POWER; Powderhorn; Parallel; p5 595; p5 590; p5 575; p5 570; p5 560Q; p5 550Q; p5 550; p5 520Q; p5 520; p5 510Q; p5 510; p5 505; p5 185; OS/400; OS/390; Oracle; OpenPower 720; OpenPower 710; OpenPower; OLAP Server DB2; Object Content Architecture; NetView; Netfinity; MVS; Microsoft Windows; Microsoft; Micro-Partitioning; Micro Channel; Magstar; Lotus; LoadLeveler; Linux; JVM; JRE; JNI; JDBC; Java Ultra; Java Naming and Directory Interface; Java; J2EE; iSeries; IPC; IntelliStation POWER 285; IntelliStation POWER 185; IntelliStation 285; IntelliStation 185; IntelliStation; Intel; install tape drive; install system; install server; install scsi adapter; install RAM; install raid enablement card; install raid enablement adapter; install raid enablement; install raid disk controller; install raid adapter; install processor; install power supply; install memory module; install memory; install iscsi adapter; install infiniband adapter; install graphics adapter; install fibre adapter; install expansion unit; install ethernet adapter; install dvd; install display; install disk drive; install disk; install DASD; install cable assembly; install async adapter; iNotes; Informix; Infoprint Language Environment; Infoprint; ibm.com; IBM Systems; IBM System p5 560Q; IBM System p5 550Q; IBM System p5 550; IBM System p5 520Q; IBM System p5 520; IBM System p5 510Q; IBM System p5 510; IBM System p5 505; IBM System p5 185; IBM System i5 520; IBM Redbooks; IBM p5 570; IBM eServer p5 595; IBM eServer p5 590; IBM eServer p5 575; IBM eServer p5 570; IBM eServer p5 550; IBM eServer p5 520; IBM eServer p5 510; IBM eServer OpenPower 720; IBM eServer OpenPower 710; IBM eServer OpenPower; IBM eServer i5 595; IBM eServer i5 570; IBM eServer i5 550; IBM eServer i5 520; IBM eServer Hardware; IBM; i5/OS; i5 595; i5 570; i5 550; i5 520; i386; Hypervisor; HiperSockets; HACMP; GPFS; General Parallel File System; GDPS; FlashCopy; FICON; Express Portfolio; Everyplace Geographically Dispersed; eServer; ESCON; Enterprise Storage Server; Electronic Service Agent; ECKD; e-business on demand; DS8000; DS6000; DS4000; Domino; Distributed Relational Database Architecture; DFSORT; DFSMSrmm; DFSMShsm; DFSMSdss; DFSMSdfp; DFSMS/MVS; DFSMS; DFS; developerWorks; DB2; DataPropagator; Cross-Site DB2; Cloudscape; ClearCase; CICS; Chipkill; Calibrated Vectored Cooling; C/400; Blue Gene; BladeCenter; BCOCA; Asset ID; AS/400e; AS/400; AnyNet; AIX 5L; AIX; AFS; AFP; AFCCU; Advanced Peer-to-Peer Networking; Advanced Function Printing; Advanced Function Presentation; AD/Cycle; 9406-595; 9406-570; 9406-550; 9406-520; 9405-520; 9133-55A; 9131-52A; 9124-720; 9123-710; 9119-595; 9119-590; 9118-575; 9117-570; 9116-561; 9115-505; 9113-550; 9111-520; 9111-285; 9110-51A; 9110-510; 7047-185; 7037-A50; IBM System p S-9133-1EJ; IBM System p S-9133-1EF; IBM System p S-9133-1ED; IBM System p S-9133-1EB; IBM System p S-9131-1KD; IBM System p S-9131-1KB; IBM System p S-9131-1K0; IBM System p S-9117-570S; IBM System p S-9117-570R; IBM System p S-9117-570P; IBM System p S-9117-570N; IBM System p S-9117-570M; IBM System p S-9117-570A; IBM System p S-9115-1F7; IBM System p S-9115-1F6; IBM System p S-9115-1F4; IBM System p S-9110-1M6; IBM System p S-9110-1M5; IBM System p S-9110-1M4; IBM System p 9133-55A Server; IBM System p 9133-1EJ; IBM System p 9133-1EH; IBM System p 9133-1EF; IBM System p 9133-1ED; IBM System p 9133-1EB; IBM System p 9133-1E8; IBM System p 9133-1E6; IBM System p 9133-1E4; IBM System p 9133-1E2; IBM System p 9133-1E0; IBM System p 9131-52A Server; IBM System p 9131-1KD; IBM System p 9131-1KB; IBM System p 9131-1K8; IBM System p 9131-1K6; IBM System p 9131-1K4; IBM System p 9131-1K2; IBM System p 9131-1K0; IBM System p 9119-595H; IBM System p 9119-595G2; IBM System p 9119-595G1; IBM System p 9119-595G; IBM System p 9119-595F; IBM System p 9119-595E; IBM System p 9119-595D2; IBM System p 9119-595D1; IBM System p 9119-595D; IBM System p 9119-595C2; IBM System p 9119-595C1; IBM System p 9119-595C; IBM System p 9119-595B2; IBM System p 9119-595B1; IBM System p 9119-595B; IBM System p 9119-595A; IBM System p 9119-595 Server; IBM System p 9119-590D1; IBM System p 9119-590D; IBM System p 9119-590C1; IBM System p 9119-590C; IBM System p 9119-590B1; IBM System p 9119-590B; IBM System p 9119-590A1; IBM System p 9119-590A; IBM System p 9119-590 Server; IBM System p 9118-575 Server; IBM System p 9117-MMA Server; IBM System p 9117-570W4; IBM System p 9117-570W3; IBM System p 9117-570W2; IBM System p 9117-570W1; IBM System p 9117-570W; IBM System p 9117-570T4; IBM System p 9117-570T3; IBM System p 9117-570T2; IBM System p 9117-570T1; IBM System p 9117-570T; IBM System p 9117-570S; IBM System p 9117-570R; IBM System p 9117-570P; IBM System p 9117-570N; IBM System p 9117-570M; IBM System p 9117-570L; IBM System p 9117-570K; IBM System p 9117-570J; IBM System p 9117-570I; IBM System p 9117-570H; IBM System p 9117-570G; IBM System p 9117-570F; IBM System p 9117-570E; IBM System p 9117-570D; IBM System p 9117-570C; IBM System p 9117-570B; IBM System p 9117-570A; IBM System p 9117-570; IBM System p 9117-570 Server; IBM System p 9116-561 Server; IBM System p 9116-1A3; IBM System p 9116-1A2; IBM System p 9116-1A1; IBM System p 9115-505 Server; IBM System p 9115-1F7; IBM System p 9115-1F6; IBM System p 9115-1F5; IBM System p 9115-1F4; IBM System p 9115-1F3; IBM System p 9115-1F2; IBM System p 9115-1F1; IBM System p 9113-550E; IBM System p 9113-550D; IBM System p 9113-550C; IBM System p 9113-550B; IBM System p 9113-550A; IBM System p 9113-550 Server; IBM System p 9111-520B; IBM System p 9111-520A; IBM System p 9111-520; IBM System p 9111-520 Server; IBM System p 9110-51A Server; IBM System p 9110-510D; IBM System p 9110-510C; IBM System p 9110-510B; IBM System p 9110-510A; IBM System p 9110-510 Server; IBM System p 9110-1M6; IBM System p 9110-1M5; IBM System p 9110-1M4; IBM System p 9110-1M3; IBM System p 9110-1M2; IBM System p 9110-1M1; IBM System p 7037-A50 Server; IBM System p 7037-1D2; IBM System p 7037-1D1; IBM System i 9411-100 Server; IBM System i 9407-515 Server; IBM System i 9406-MMA Server; IBM System i 9406-595 Server; IBM System i 9406-570 Server; IBM System i 9406-550 Server; IBM System i 9406-525 Server; IBM System i 9406-520 Server; IBM System i 9406-270 Server; IBM System i 9405-520 Server; IBM RS/6000 9076-T70 Server; IBM RS/6000 9076-55H Server; IBM RS/6000 9076-558 Server; IBM RS/6000 9076-557 Server; IBM RS/6000 9076-556 Server; IBM RS/6000 9076-555 Server; IBM RS/6000 9076-550 Server; IBM RS/6000 9076-50H Server; IBM RS/6000 9076-500 Server; IBM RS/6000 9076-40A Server; IBM RS/6000 9076-409 Server; IBM RS/6000 9076-408 Server; IBM RS/6000 9076-407 Server; IBM RS/6000 9076-406 Server; IBM RS/6000 9076-3BA Server; IBM RS/6000 9076-3B9 Server; IBM RS/6000 9076-3B8 Server; IBM RS/6000 9076-3B7 Server; IBM RS/6000 9076-3AA Server; IBM RS/6000 9076-3A9 Server; IBM RS/6000 9076-3A8 Server; IBM RS/6000 9076-3A7 Server; IBM RS/6000 9076-30A Server; IBM RS/6000 9076-309 Server; IBM RS/6000 9076-308 Server; IBM RS/6000 9076-307 Server; IBM RS/6000 9076-306 Server; IBM RS/6000 9076-2AA Server; IBM RS/6000 9076-2A9 Server; IBM RS/6000 9076-2A8 Server; IBM RS/6000 9076-2A7 Server; IBM RS/6000 9076-20A Server; IBM RS/6000 9076-209 Server; IBM RS/6000 9076-208 Server; IBM RS/6000 9076-207 Server; IBM RS/6000 9076-206 Server; IBM RS/6000 7015-S7A Server; IBM RS/6000 7015-S70 Server; IBM RS/6000 7015-R5U Server; IBM RS/6000 7015-R50 Server; IBM RS/6000 7015-R4U Server; IBM RS/6000 7015-R40 Server; IBM RS/6000 7015-R30 Server; IBM RS/6000 7015-R24 Server; IBM RS/6000 7015-R21 Server; IBM RS/6000 7015-R20 Server; IBM RS/6000 7015-R10 Server; IBM RS/6000 7015-99F Server; IBM RS/6000 7015-99E Server; IBM RS/6000 7015-990 Server; IBM RS/6000 7015-98B Server; IBM RS/6000 7015-980 Server; IBM RS/6000 7015-97B Server; IBM RS/6000 7015-970 Server; IBM RS/6000 7015-95E Server; IBM RS/6000 7015-951 Server; IBM RS/6000 7015-950 Server; IBM RS/6000 7015-930 Server; IBM RS/6000 7013-S7A Server; IBM RS/6000 7013-S70 Server; IBM RS/6000 7013-J50 Server; IBM RS/6000 7013-J40 Server; IBM RS/6000 7013-J30 Server; IBM RS/6000 7013-J01 Server; IBM RS/6000 7013-59H Server; IBM RS/6000 7013-595 Server; IBM RS/6000 7013-591 Server; IBM RS/6000 7013-590 Server; IBM RS/6000 7013-58H Server; IBM RS/6000 7013-581 Server; IBM RS/6000 7013-580 Server; IBM RS/6000 7013-57L Server; IBM RS/6000 7013-57F Server; IBM RS/6000 7013-571 Server; IBM RS/6000 7013-570 Server; IBM RS/6000 7013-560 Server; IBM RS/6000 7013-55L Server; IBM RS/6000 7013-550 Server; IBM RS/6000 7013-540 Server; IBM RS/6000 7013-53H Server; IBM RS/6000 7013-53E Server; IBM RS/6000 7013-530 Server; IBM RS/6000 7013-52H Server; IBM RS/6000 7013-52E Server; IBM RS/6000 7013-520 Server; IBM pSeries S-7029-6C3-2; IBM pSeries S-7029-6C3-1; IBM pSeries S-7029-6C3; IBM pSeries 7046-B50 Server; IBM pSeries 7044-270 Server; IBM pSeries 7044-170 Server; IBM pSeries 7043-270 Server; IBM pSeries 7043-260 Server; IBM pSeries 7043-240 Server; IBM pSeries 7043-150 Server; IBM pSeries 7043-140 Server; IBM pSeries 7040-681 Server; IBM pSeries 7040-671 Server; IBM pSeries 7039-651 Server; IBM pSeries 7038-6M2 Server; IBM pSeries 7029-6E3 Server; IBM pSeries 7029-6C3 Server; IBM pSeries 7029-284C; IBM pSeries 7029-280C; IBM pSeries 7029-244C; IBM pSeries 7029-240C; IBM pSeries 7029-224C; IBM pSeries 7029-220C; IBM pSeries 7029-180C; IBM pSeries 7029-140C; IBM pSeries 7029-120C; IBM pSeries 7029-110C; IBM pSeries 7028-6E4 Server; IBM pSeries 7028-6E1 Server; IBM pSeries 7028-6C4 Server; IBM pSeries 7028-6C1 Server; IBM pSeries 7026-M80 Server; IBM pSeries 7026-H80 Server; IBM pSeries 7026-H70 Server; IBM pSeries 7026-H50 Server; IBM pSeries 7026-H10 Server; IBM pSeries 7026-B80 Server; IBM pSeries 7026-6M1 Server; IBM pSeries 7026-6H1 Server; IBM pSeries 7026-6H0 Server; IBM pSeries 7025-H70 Server; IBM pSeries 7025-F80 Server; IBM pSeries 7025-F50 Server; IBM pSeries 7025-F40 Server; IBM pSeries 7025-F30 Server; IBM pSeries 7025-6F1 Server; IBM pSeries 7025-6F0 Server; IBM pSeries 7017-S85 Server; IBM pSeries 7017-S80 Server; IBM pSeries 7017-S7A Server; IBM pSeries 7017-S70 Server; IBM OpenPower S-9124-720-4; IBM OpenPower S-9124-720-3; IBM OpenPower S-9124-720-2; IBM OpenPower S-9124-720-1; IBM OpenPower S-9124-720-0; IBM OpenPower S-9123-710-1; IBM OpenPower S-9123-710-0; IBM OpenPower S1-9124-720-4; IBM OpenPower S1-9124-720-3; IBM OpenPower S1-9124-720-2; IBM OpenPower S1-9124-720-1; IBM OpenPower S1-9124-720-0; IBM OpenPower S1-9123-710-1; IBM OpenPower S1-9123-710-0; IBM OpenPower 9124-720-4; IBM OpenPower 9124-720-3; IBM OpenPower 9124-720-2; IBM OpenPower 9124-720-1; IBM OpenPower 9124-720-0; IBM OpenPower 9124-720 Server; IBM OpenPower 9123-710-1; IBM OpenPower 9123-710-0; IBM OpenPower 9123-710 Server; IBM OpenPower 9123-1C6 Server; IBM OpenPower 9123-1C5 Server; IBM OpenPower 9123-1C4 Server; IBM OpenPower 9123-1C3 Server; IBM OpenPower 9123-1C2 Server; IBM OpenPower 9123-1C1 Server; IBM OpenPower 9123-1B6 Server; IBM OpenPower 9123-1B5 Server; IBM OpenPower 9123-1B4 Server; IBM OpenPower 9123-1B3 Server; IBM OpenPower 9123-1B2 Server; IBM OpenPower 9123-1B1 Server; IBM OpenPower 9123-1A8 Server; IBM OpenPower 9123-1A7 Server; IBM OpenPower 9123-1A6 Server; IBM OpenPower 9123-1A5 Server; IBM OpenPower 9123-1A4 Server; IBM OpenPower 9123-1A3 Server; IBM OpenPower 9123-1A2 Server; IBM OpenPower 9123-1A1 Server; IBM iSeries 9406-SB3 Server; IBM iSeries 9406-SB2 Server; IBM iSeries 9406-SB1 Server; IBM iSeries 9406-S40 Server; IBM iSeries 9406-S30 Server; IBM iSeries 9406-S20 Server; IBM iSeries 9406-S10 Server; IBM iSeries 9406-890 Server; IBM iSeries 9406-870 Server; IBM iSeries 9406-840 Server; IBM iSeries 9406-830 Server; IBM iSeries 9406-825 Server; IBM iSeries 9406-820 Server; IBM iSeries 9406-810 Server; IBM iSeries 9406-800 Server; IBM iSeries 9406-740 Server; IBM iSeries 9406-730 Server; IBM iSeries 9406-720 Server; IBM iSeries 9406-650 Server; IBM iSeries 9406-640 Server; IBM iSeries 9406-620 Server; IBM iSeries 9406-600 Server; IBM iSeries 9406-250 Server; IBM iSeries 9406-170 Server; IBM IntelliStation S-9114-275; IBM IntelliStation 9114-275 Workstation; IBM IntelliStation 9114-240W; IBM IntelliStation 9114-140W; IBM IntelliStation 9114-100W; IBM IntelliStation 9112-265 Server; IBM IntelliStation 9111-290W+; IBM IntelliStation 9111-290W; IBM IntelliStation 9111-285 Workstation; IBM IntelliStation 9111-190W+; IBM IntelliStation 9111-190W; IBM IntelliStation 7047-250W; IBM IntelliStation 7047-185 Workstation; IBM IntelliStation 7047-150W; IBM Tape Drive; IBM Tape 911x-6279; IBM Tape 911x-6258; IBM Tape 911x-6120; IBM Tape 911x-5755; IBM Tape 911x-1997; IBM Tape 911x-1992; IBM Tape 911x-1991; IBM Tape 911x-1955; IBM Tape 911x-1892; IBM SCSI RAID Enablement Adapter; IBM SCSI RAID Enablement 911x-5737; IBM SCSI RAID Enablement 911x-5736; IBM SCSI RAID Enablement 911x-5728; IBM SCSI RAID Enablement 911x-5727; IBM SCSI RAID Enablement 911x-5726; IBM SCSI RAID Enablement 911x-5712; IBM SCSI RAID Enablement 911x-5711; IBM SCSI RAID Enablement 911x-5710; IBM SCSI RAID Enablement 911x-5709; IBM SCSI RAID Enablement 911x-5703; IBM SCSI RAID Enablement 911x-1976; IBM SCSI RAID Enablement 911x-1975; IBM SCSI RAID Enablement 911x-1974; IBM SCSI RAID Enablement 911x-1913; IBM SCSI RAID Enablement 911x-1912; IBM SCSI RAID Enablement 911x-1908; IBM SCSI RAID Enablement 911x-1907; IBM Power Supply; IBM Power 911x-7989; IBM Power 911x-7958; IBM Power 911x-7889; IBM Power 911x-7875; IBM Power 911x-6186; IBM Power 911x-5159; IBM Power 911x-5158; IBM Memory Upgrade; IBM Memory 911x-7896; IBM Memory 911x-7894; IBM Memory 911x-7893; IBM Memory 911x-7892; IBM Memory 911x-4498; IBM Memory 911x-4497; IBM Memory 911x-4492; IBM Memory 911x-4491; IBM Memory 911x-4490; IBM Memory 911x-4463; IBM Memory 911x-4462; IBM Memory 911x-4461; IBM Memory 911x-4460; IBM Memory 911x-4454; IBM Memory 911x-4452; IBM Memory 911x-4451; IBM Memory 911x-4450; IBM Memory 911x-4449; IBM Memory 911x-4447; IBM Memory 911x-4446; IBM Memory 911x-4445; IBM Memory 911x-4444; IBM Memory 911x-4443; IBM Memory 911x-1952; IBM Memory 911x-1951; IBM Memory 911x-1950; IBM Memory 911x-1949; IBM Memory 911x-1945; IBM Memory 911x-1942; IBM Memory 911x-1940; IBM Memory 911x-1938; IBM Memory 911x-1937; IBM Memory 911x-1936; IBM Memory 911x-1934; IBM Memory 911x-1932; IBM Memory 911x-1931; IBM Memory 911x-1930; IBM iSCSI 911x-5714; IBM iSCSI 911x-5713; IBM iSCSI 911x-1987; IBM iSCSI 911x-1986; IBM iSCSI; IBM InfiniBand Adapter; IBM InfiniBand 911x-7820; IBM InfiniBand 911x-1820; IBM InfiniBand 911x-1812; IBM InfiniBand 911x-1811; IBM InfiniBand 911x-1810; IBM InfiniBand 911x-1809; IBM Graphics Adapter; IBM Graphic 911x-2849; IBM Graphic 911x-2843; IBM Graphic 911x-2842; IBM Graphic 911x-1980; IBM Fibre Adapter; IBM Fibre 911x-6239; IBM Fibre 911x-6228; IBM Fibre 911x-5759; IBM Fibre 911x-5758; IBM Fibre 911x-5716; IBM Fibre 911x-1977; IBM Fibre 911x-1957; IBM Fibre 911x-1910; IBM Fibre 911x-1905; IBM Expansion Unit; IBM Expansion 911x-7863; IBM Expansion 911x-7862; IBM Expansion 911x-7861; IBM Expansion 911x-7818; IBM Expansion 911x-7164; IBM Expansion 911x-6594; IBM Expansion 911x-6593; IBM Expansion 911x-6592; IBM Expansion 911x-6574; IBM Expansion 911x-5795; IBM Expansion 911x-5794; IBM Expansion 911x-5791; IBM Expansion 911x-1800; IBM Ethernet Adapter; IBM Ethernet 911x-5740; IBM Ethernet 911x-5722; IBM Ethernet 911x-5721; IBM Ethernet 911x-5719; IBM Ethernet 911x-5718; IBM Ethernet 911x-5707; IBM Ethernet 911x-5706; IBM Ethernet 911x-5701; IBM Ethernet 911x-5700; IBM Ethernet 911x-4962; IBM Ethernet 911x-4961; IBM Ethernet 911x-4959; IBM Ethernet 911x-2975; IBM Ethernet 911x-2969; IBM Ethernet 911x-1990; IBM Ethernet 911x-1985; IBM Ethernet 911x-1984; IBM Ethernet 911x-1983; IBM Ethernet 911x-1982; IBM Ethernet 911x-1981; IBM Ethernet 911x-1979; IBM Ethernet 911x-1978; IBM Ethernet 911x-1959; IBM Ethernet 911x-1954; IBM DVD Device; IBM DVD 911x-5764; IBM DVD 911x-5763; IBM DVD 911x-5751; IBM DVD 911x-2640; IBM DVD 911x-2591; IBM DVD 911x-1994; IBM DVD 911x-1993; IBM DVD 911x-1903; IBM DVD 911x-1900; IBM Display 911x-3645; IBM Display 911x-3644; IBM Display 911x-3643; IBM Display 911x-3642; IBM Display 911x-3641; IBM Display 911x-3640; IBM Display 911x-3639; IBM Display 911x-3638; IBM Display 911x-3637; IBM Display 911x-3636; IBM Display; IBM Disk Drive; IBM Disk 911x-3581; IBM Disk 911x-3580; IBM Disk 911x-3579; IBM Disk 911x-3578; IBM Disk 911x-3281; IBM Disk 911x-3280; IBM Disk 911x-3279; IBM Disk 911x-3278; IBM Disk 911x-3277; IBM Disk 911x-3276; IBM Disk 911x-3275; IBM Disk 911x-3274; IBM Disk 911x-3273; IBM Disk 911x-3265; IBM Disk 911x-3264; IBM Disk 911x-3159; IBM Disk 911x-3158; IBM Disk 911x-3129; IBM Disk 911x-1973; IBM Disk 911x-1972; IBM Disk 911x-1971; IBM Disk 911x-1970; IBM Disk 911x-1969; IBM Disk 911x-1968; IBM Cable Assembly; IBM Cable 911x-8133; IBM Cable 911x-8132; IBM Cable 911x-8131; IBM Cable 911x-7802; IBM Cable 911x-7801; IBM Cable 911x-6123; IBM Cable 911x-6029; IBM Cable 911x-6008; IBM Cable 911x-6007; IBM Cable 911x-6006; IBM Cable 911x-6001; IBM Cable 911x-4278; IBM Cable 911x-4274; IBM Cable 911x-4273; IBM Cable 911x-4267; IBM Cable 911x-4263; IBM Cable 911x-4256; IBM Cable 911x-4242; IBM Cable 911x-3926; IBM Cable 911x-3925; IBM Cable 911x-3168; IBM Cable 911x-3156; IBM Cable 911x-3148; IBM Cable 911x-3147; IBM Cable 911x-3146; IBM Cable 911x-3125; IBM Cable 911x-3124; IBM Cable 911x-2936; IBM Cable 911x-2459; IBM Cable 911x-2456; IBM Cable 911x-2425; IBM Cable 911x-2118; IBM Cable 911x-2114; IBM Cable 911x-1839; IBM Cable 911x-1836; IBM Cable 911x-1835; IBM Async Adapter; IBM Async 911x-8137; IBM Async 911x-8136; IBM Async 911x-6312; IBM Async 911x-5723; IBM Async 911x-2947; IBM Async 911x-2944; IBM Async 911x-2943; IBM SCSI RAID 7311-5737; IBM SCSI RAID 7311-5736; IBM SCSI RAID 7311-5712; IBM SCSI RAID 7311-5703; IBM SCSI RAID 7040-5737; IBM SCSI RAID 7040-5736; IBM SCSI RAID 7040-5711; IBM SCSI RAID 7040-5710; IBM SCSI RAID; IBM Power 7031-6261; IBM Power; IBM iSCSI 7311-5714; IBM iSCSI 7311-5713; IBM iSCSI 7040-5714; IBM iSCSI 7040-5713; IBM iSCSI; IBM InfiniBand 7311-1820; IBM InfiniBand 7040-1820; IBM InfiniBand; IBM I/O Tower 7031-T24; IBM I/O Drawer 7311-D20; IBM I/O Drawer 7311-D11; IBM I/O Drawer 7311-D10; IBM I/O Drawer 7040-61D; IBM I/O Drawer 7031-D24; IBM Graphics 7311-2849; IBM Graphics 7040-2849; IBM Graphics; IBM Fibre 7311-6239; IBM Fibre 7311-6228; IBM Fibre 7311-5759; IBM Fibre 7311-5758; IBM Fibre 7311-5716; IBM Fibre 7040-6239; IBM Fibre 7040-6228; IBM Fibre 7040-5759; IBM Fibre 7040-5758; IBM Fibre 7040-5716; IBM Fibre; IBM Expansion 7031-5742; IBM Expansion 7031-5741; IBM Expansion; IBM Ethernet 7311-5740; IBM Ethernet 7311-5722; IBM Ethernet 7311-5721; IBM Ethernet 7311-5719; IBM Ethernet 7311-5718; IBM Ethernet 7311-5707; IBM Ethernet 7311-5706; IBM Ethernet 7311-5701; IBM Ethernet 7311-5700; IBM Ethernet 7311-4962; IBM Ethernet 7311-4961; IBM Ethernet 7040-5740; IBM Ethernet 7040-5722; IBM Ethernet 7040-5721; IBM Ethernet 7040-5719; IBM Ethernet 7040-5718; IBM Ethernet 7040-5707; IBM Ethernet 7040-5706; IBM Ethernet 7040-5701; IBM Ethernet 7040-5700; IBM Ethernet 7040-4962; IBM Ethernet 7040-4961; IBM Ethernet 7040-2975; IBM Ethernet 7040-2969; IBM Ethernet; IBM Disk 7311-3578; IBM Disk 7311-3279; IBM Disk 7311-3278; IBM Disk 7311-3277; IBM Disk 7311-3275; IBM Disk 7311-3274; IBM Disk 7311-3273; IBM Disk 7040-3578; IBM Disk 7040-3279; IBM Disk 7040-3278; IBM Disk 7040-3277; IBM Disk 7040-3275; IBM Disk 7040-3159; IBM Disk 7040-3158; IBM Disk 7031-3578; IBM Disk 7031-3279; IBM Disk 7031-3278; IBM Disk 7031-3277; IBM Disk 7031-3275; IBM Disk 7031-3274; IBM Disk; IBM Async 7311-5723; IBM Async 7040-5723; IBM Async; IBM I/O Drawer; IBM VX3 Tape Drive 7212-1114; IBM VX3 Tape Drive 7206-VX3; IBM VX2 Tape Drive 7212-1104; IBM VX2 Tape Drive 7206-VX2; IBM VX2 Autoloader 7212-312; IBM Ultrium LTO4 Tape Drive 3588-F4A; IBM Ultrium LTO4 Tape Drive 3580-S43; IBM Ultrium LTO4 Tape Drive 3580-L43; IBM Ultrium LTO4 Tape Drive 3576-8142; IBM Ultrium LTO4 Tape Drive 3576-8139; IBM Ultrium LTO4 Tape Drive 3573-8145; IBM Ultrium LTO4 Tape Drive 3573-8144; IBM Ultrium LTO4 Tape Drive 3573-8143; IBM Ultrium LTO3 Tape Drive 3588-F3B; IBM Ultrium LTO3 Tape Drive 3588-F3A; IBM Ultrium LTO3 Tape Drive 3583-8035; IBM Ultrium LTO3 Tape Drive 3583-8033; IBM Ultrium LTO3 Tape Drive 3582-8036; IBM Ultrium LTO3 Tape Drive 3582-8035; IBM Ultrium LTO3 Tape Drive 3582-8034; IBM Ultrium LTO3 Tape Drive 3582-8033; IBM Ultrium LTO3 Tape Drive 3580-L33; IBM Ultrium LTO3 Tape Drive 3580-H3L; IBM Ultrium LTO3 Tape Drive 3576-8042; IBM Ultrium LTO3 Tape Drive 3576-8038; IBM Ultrium LTO3 Tape Drive 3576-8037; IBM Ultrium LTO3 Tape Drive 3573-8044; IBM Ultrium LTO3 Tape Drive 3573-8043; IBM Ultrium LTO3 Autoloader 3581-L38; IBM Ultrium LTO3 Autoloader 3581-F38; IBM Ultrium LTO2 Tape Drive 3583-8105; IBM Ultrium LTO2 Tape Drive 3583-8104; IBM Ultrium LTO2 Tape Drive 3583-8103; IBM Ultrium LTO2 Tape Drive 3582-8205; IBM Ultrium LTO2 Tape Drive 3582-8204; IBM Ultrium LTO2 Tape Drive 3582-8203; IBM Ultrium LTO2 Tape Drive 3582-8105; IBM Ultrium LTO2 Tape Drive 3582-8104; IBM Ultrium LTO2 Tape Drive 3582-8103; IBM Ultrium LTO2 Tape Drive 3580-L23; IBM Ultrium LTO2 Tape Drive 3580-H23; IBM Ultrium LTO2 Half-High Tape Drive 7212-1109; IBM Ultrium LTO2 Autoloader 3581-L28; IBM Ultrium LTO2 Autoloader 3581-L23; IBM Ultrium LTO2 Autoloader 3581-H23; IBM Ultrium LTO2 Autoloader 3581-F28; IBM Ultrium LTO1 Tape Drive 3583-8004; IBM Ultrium LTO1 Tape Drive 3583-8003; IBM Ultrium LTO1 Tape Drive 3580-L13; IBM Ultrium LTO1 Tape Drive 3580-L11; IBM Ultrium LTO1 Tape Drive 3580-H13; IBM Ultrium LTO1 Tape Drive 3580-H11; IBM Ultrium LTO1 Autoloader 3581-L17; IBM Ultrium LTO1 Autoloader 3581-L13; IBM Ultrium LTO1 Autoloader 3581-H17; IBM Ultrium LTO1 Autoloader 3581-H13; IBM Ultrium LTO Library 3582-L23; IBM TS3500 Library 3584-L53; IBM TS3500 Library 3584-L23; IBM TS3500 Expansion 3584-D53; IBM TS3500 Expansion 3584-D23; IBM TS3310 Library 3576-L5B; IBM TS3310 Expansion 3576-E9U; IBM TS3200 Library 3573-L4U; IBM TS3100 Autoloader 3573-L2U; IBM Storage Device Enclosure 7212-103; IBM Storage Device Enclosure 7212-102; IBM SLR60 Tape Drive 7212-1107; IBM SLR60 Tape Drive 7207-330; IBM SLR5 Tape Drive 7207-122; IBM SLR100 Tape Drive 7212-1108; IBM SDLT320 Tape Drive 7205-550; IBM Mammoth2 Tape Drive 7208-345; IBM Mammoth1 Tape Drive 7208-342; IBM Mammoth1 Tape Drive 7208-341; IBM Library 3583-L72; IBM Library 3583-L36; IBM Library 3583-L18; IBM DVD RAM2 Drive 7212-1103; IBM DDS4 Tape Drive 7212-1100; IBM DDS4 Tape Drive 7206-220; IBM DDS4 Autoloader 7332-220; IBM DAT72 Tape Drive 7212-1105; IBM DAT72 Tape Drive 7206-336; IBM 8mm Tape Drive 7208-222; IBM 7332 Autoloader; IBM 7212 Autoloader; IBM 7208 Tape Drive; IBM 7207 Tape Drive; IBM 7206 Tape Drive; IBM 7205 Tape Drive; IBM 3588 Ultrium LTO Tape Drive; IBM 3584 Tape Library Frame; IBM 3583 Ultrium LTO Library; IBM 3582 Ultrium LTO Library; IBM 3581-7004; IBM 3581-7003; IBM 3581-3104; IBM 3581 Ultrium LTO Autoloader; IBM 3580 Ultrium LTO Tape Drive; IBM 3576-7003; IBM 3576-5900; IBM 3576-1900; IBM 3576-1682; IBM 3576-1640; IBM 3576 Ultrium LTO Library; IBM 3573-8106; IBM 3573-7002; IBM 3573-5900; IBM 3573-1682; IBM 3573 Ultrium LTO Autoloader Library; IBM TotalStorage Storage EXP700 EXP710 Expansion; IBM TotalStorage EXP400 Storage Expansion; IBM TotalStorage DS400; IBM TotalStorage DS300 iSCSI; IBM System Storage EXN1000 Expansion; IBM System Storage 2865 N Series; IBM System Storage 2864 N Series; IBM System Storage 2863 N Series; IBM Storage Tower 2104-TU3; IBM Storage Tower 2104-TS4; IBM Storage Drawer S-2104-4646; IBM Storage Drawer S-2104-4573; IBM Storage Drawer S-2104-4536; IBM Storage Drawer S-2104-4328; IBM Storage Drawer S-2104-4327; IBM Storage Drawer S-2104-4326; IBM Storage Drawer S-2104-4300; IBM Storage Drawer S-2104-4146; IBM Storage Drawer S-2104-4073; IBM Storage Drawer S-2104-4036; IBM Storage Drawer 2104-DU3; IBM Storage Drawer 2104-DS4; IBM Storage 2104-6572; IBM Storage 2104-6536; IBM Storage 2104-6246; IBM Storage 2104-6172; IBM Storage 2104-6136; IBM Storage 2104-4646; IBM Storage 2104-4573; IBM Storage 2104-4536; IBM Storage 2104-4300; IBM Storage 2104-4146; IBM Storage 2104-4073; IBM Storage 2104-4036; IBM Storage 2104-3499; IBM Storage 2104-3448; IBM Storage 2104-3430; IBM Storage 2104-3299; IBM Storage 2104-3248; IBM Storage 2104-3230; IBM Storage 2104-2642; IBM Storage 2104-2635; IBM NAS 500 Memory 5198-4490; IBM NAS 500 Memory 5198-4454; IBM NAS 500 Memory 5198-4452; IBM NAS 500 Fibre 5198-6240; IBM NAS 500 Fibre 5198-6239; IBM NAS 500 Ethernet 5198-5707; IBM NAS 500 Ethernet 5198-5706; IBM NAS 500 Ethernet 5198-5701; IBM NAS 500 Ethernet 5198-5700; IBM NAS 500 5198-001; IBM N5500 2865-A20; IBM N5500 2865-A10; IBM N5500 2865-1005; IBM N5500 2865-1004; IBM N5500 2865-1003; IBM N5200 2864-A20; IBM N5200 2864-A10; IBM N5200 2864-1005; IBM N5200 2864-1004; IBM N5200 2864-1003; IBM N3700 Disk 2863-4004; IBM N3700 Disk 2863-4003; IBM N3700 Disk 2863-4002; IBM N3700 Disk 2863-4001; IBM N3700 Disk 2863-4000; IBM N3700 2863-A20; IBM N3700 2863-A10; IBM N3700 2863-001; IBM N3700; IBM Midrange DS4400 FAStT700 FAStT900 Disk; IBM Midrange DS4300 FAStT600 Disk; IBM Midrange DS4100 FAStT100 Disk; IBM FAStT500 Storage Server; IBM FAStT500 3552-1RU; IBM FAStT EXP500 Expansion; IBM EXP700 Disk 1740-5214; IBM EXP700 Disk 1740-5213; IBM EXP700 Disk 1740-5212; IBM EXP700 Disk 1740-5211; IBM EXP700 Disk 1740-5208; IBM EXP700 Disk 1740-5207; IBM EXP700 Disk 1740-5206; IBM EXP700 Disk 1740-5205; IBM EXP700 1740-710; IBM EXP700 1740-1RU; IBM EXP500 Disk 3560-5213; IBM EXP500 Disk 3560-5212; IBM EXP500 Disk 3560-5211; IBM EXP500 Disk 3560-5207; IBM EXP500 Disk 3560-5206; IBM EXP500 Disk 3560-5205; IBM EXP500 Disk 3560-5011; IBM EXP500 Disk 3560-5006; IBM EXP500 Disk 3560-5005; IBM EXP500 Disk 3560-5004; IBM EXP500 3560-1RU; IBM EXP400 Disk 90p1382; IBM EXP400 Disk 90p1381; IBM EXP400 Disk 90p1380; IBM EXP400 Disk 90p1307; IBM EXP400 Disk 90p1306; IBM EXP400 Disk 90p1305; IBM EXP400 1733-1RU; IBM EXN1000 2861-001; IBM ESS Disk Array; IBM ESS Disk 2105-2144; IBM ESS Disk 2105-2143; IBM ESS Disk 2105-2142; IBM ESS Disk 2105-2125; IBM ESS Disk 2105-2124; IBM ESS Disk 2105-2123; IBM ESS Disk 2105-2122; IBM ESS Cache 2105-4020; IBM ESS Cache 2105-4016; IBM ESS Cache 2105-4015; IBM ESS Cache 2105-4014; IBM ESS Cache 2105-4006; IBM ESS Cache 2105-4005; IBM ESS Cache 2105-4004; IBM ESS 2105-800; IBM ESS 2105-750; IBM Enterprise NAS 500 Gateway; IBM DS8000 Disk Array; IBM DS8000 Disk 2107-2316; IBM DS8000 Disk 2107-2116; IBM DS8000 Disk 2107-2016; IBM DS8000 Cache 2107-4105; IBM DS8000 Cache 2107-4104; IBM DS8000 Cache 2107-4103; IBM DS8000 Cache 2107-4102; IBM DS8000 Cache 2107-4004; IBM DS8000 Cache 2107-4003; IBM DS8000 Cache 2107-4002; IBM DS8000 Cache 2107-4001; IBM DS8000 2107-9AE; IBM DS8000 2107-9A2; IBM DS8000 2107-92E; IBM DS8000 2107-922; IBM DS8000 2107-921; IBM DS6000 Disk Array; IBM DS6000 Disk 1750-2054; IBM DS6000 Disk 1750-2052; IBM DS6000 Disk 1750-2004; IBM DS6000 Disk 1750-2002; IBM DS6000 1750-EX1; IBM DS6000 1750-511; IBM DS4400 1742-90U; IBM DS4400 1742-1RU; IBM DS4300 Disk 1722-5214; IBM DS4300 Disk 1722-5213; IBM DS4300 Disk 1722-5212; IBM DS4300 Disk 1722-5211; IBM DS4300 Disk 1722-5208; IBM DS4300 Disk 1722-5207; IBM DS4300 Disk 1722-5206; IBM DS4300 Disk 1722-5205; IBM DS4300 1722-6LU; IBM DS4300 1722-60U; IBM DS4300 1722-60U; IBM DS4100 Disk 1724-4602; IBM DS4100 1724-100; IBM DS400 Disk 90p1382; IBM DS400 Disk 90p1381; IBM DS400 Disk 90p1380; IBM DS400 Disk 90p1307; IBM DS400 Disk 90p1306; IBM DS400 Disk 90p1305; IBM DS400 1700-2RD; IBM DS400 1700-1RS; IBM DS300 Disk 90p1382; IBM DS300 Disk 90p1381; IBM DS300 Disk 90p1380; IBM DS300 Disk 90p1307; IBM DS300 Disk 90p1306; IBM DS300 Disk 90p1305; IBM DS300 1701-2RD; IBM DS300 1701-1RS; IBM Disk 7204-646; IBM Disk 7204-573; IBM Disk 7204-536; IBM Disk 7204-518; IBM 7204 External Disk; IBM 2104 Storage Tower; IBM 2104 Storage Drawer; IBM UPS; IBM Rack Enclosure; IBM HMC Console; IBM Flat Panel Console; IBM 9910-P65; IBM 9910-P64; IBM 9910-P33; IBM 9910-P30; IBM 7316-TF3; IBM 7316-8880; IBM 7316-4269; IBM 7316-4268; IBM 7316-4242; IBM 7316-4202; IBM 7310-CR3; IBM 7310-7802; IBM 7310-7801; IBM 7310-5706; IBM 7310-4962; IBM 7310-4256; IBM 7310-4242; IBM 7310-3645; IBM 7310-3644; IBM 7310-3643; IBM 7310-3642; IBM 7310-3641; IBM 7310-3640; IBM 7310-3637; IBM 7310-2591; IBM 7014-T42; IBM 7014-T00; IBM 7014-S25; IBM 7014-S11 Company : GST, Inc. Source Modified : D:20070902141659 Creator Tool : Acrobat PDFMaker 8.1 for Word Modify Date : 2007:09:05 23:49:15-07:00 Create Date : 2007:09:02 07:17:24-07:00 Metadata Date : 2007:09:05 23:49:15-07:00 Document ID : uuid:357385be-7310-4c9f-9613-81220e7e9a2c Instance ID : uuid:6b1f5f6e-b9d5-452a-89ec-7340ef080352 Format : application/pdf Creator : GST, Inc. - http://www.gstinc.com/store/IBM-C552.aspx Title : GST, Inc. - IBM System p, p5, pSeries, RS/6000, System i, i5, iSeries, AS/400, OpenPower and TotalStorage Experts. Description : GST, Inc. - IBM System p, p5, pSeries, RS/6000, System i, i5, iSeries, AS/400, OpenPower and TotalStorage Experts. Subject : www.gstinc.com, http://www.gstinc.com, gstinc.com, GST Inc, GST, David Breisacher, Breisacher, zSeries, z9, z/VSE, z/VM, z/OS, xSeries, Windows Server, Windows NT, Windows, WebSphere 1350, WebSphere, Virtualization Engine, UNIX, Universal Database DB2, Trackpoint, TotalStorage, Tivoli, System/38, System/36, System z, System x, System Storage, System p5, System p, System i5, System i, Sysplex, Sun Solaris, StorageTek, Solaris, Service Director, ServerProven, ServeRAID, SecureWay, Seascape, S/390, RSM, RS/6000, RPG/400, RISC System/6000, replace tape drive, replace system, replace server, replace scsi adapter, replace RAM, replace raid enablement card, replace raid enablement adapter, replace raid enablement, replace raid disk controller, replace raid adapter, replace processor, replace power supply, replace memory module, replace memory, replace iscsi adapter, replace infiniband adapter, replace graphics adapter, replace fibre adapter, replace expansion unit, replace ethernet adapter, replace dvd, replace display, replace disk drive, replace disk, replace DASD, replace cable assembly, replace async adapter, remove tape drive, remove system, remove server, remove scsi adapter, remove RAM, remove raid enablement card, remove raid enablement adapter, remove raid enablement, remove raid disk controller, remove raid adapter, remove processor, remove power supply, remove memory module, remove memory, remove iscsi adapter, remove infiniband adapter, remove graphics adapter, remove fibre adapter, remove expansion unit, remove ethernet adapter, remove dvd, remove display, remove disk drive, remove disk, remove DASD, remove cable assembly, remove async adapter, Redbooks, PTX, pSeries, Predictive Failure Analysis, POWERserver, PowerPC Architecture, PowerPC 750, PowerPC, PowerExecutive, POWER6, POWER5+, POWER5, POWER4, POWER3, POWER2, Power Series, Power PC, Power Management, POWER Hypervisor, Power Architecture, POWER, Powderhorn, Parallel, p5 595, p5 590, p5 575, p5 570, p5 560Q, p5 550Q, p5 550, p5 520Q, p5 520, p5 510Q, p5 510, p5 505, p5 185, OS/400, OS/390, Oracle, OpenPower 720, OpenPower 710, OpenPower, OLAP Server DB2, Object Content Architecture, NetView, Netfinity, MVS, Microsoft Windows, Microsoft, Micro-Partitioning, Micro Channel, Magstar, Lotus, LoadLeveler, Linux, JVM, JRE, JNI, JDBC, Java Ultra, Java Naming and Directory Interface, Java, J2EE, iSeries, IPC, IntelliStation POWER 285, IntelliStation POWER 185, IntelliStation 285, IntelliStation 185, IntelliStation, Intel, install tape drive, install system, install server, install scsi adapter, install RAM, install raid enablement card, install raid enablement adapter, install raid enablement, install raid disk controller, install raid adapter, install processor, install power supply, install memory module, install memory, install iscsi adapter, install infiniband adapter, install graphics adapter, install fibre adapter, install expansion unit, install ethernet adapter, install dvd, install display, install disk drive, install disk, install DASD, install cable assembly, install async adapter, iNotes, Informix, Infoprint Language Environment, Infoprint, ibm.com, IBM Systems, IBM System p5 560Q, IBM System p5 550Q, IBM System p5 550, IBM System p5 520Q, IBM System p5 520, IBM System p5 510Q, IBM System p5 510, IBM System p5 505, IBM System p5 185, IBM System i5 520, IBM Redbooks, IBM p5 570, IBM eServer p5 595, IBM eServer p5 590, IBM eServer p5 575, IBM eServer p5 570, IBM eServer p5 550, IBM eServer p5 520, IBM eServer p5 510, IBM eServer OpenPower 720, IBM eServer OpenPower 710, IBM eServer OpenPower, IBM eServer i5 595, IBM eServer i5 570, IBM eServer i5 550, IBM eServer i5 520, IBM eServer Hardware, IBM, i5/OS, i5 595, i5 570, i5 550, i5 520, i386, Hypervisor, HiperSockets, HACMP, GPFS, General Parallel File System, GDPS, FlashCopy, FICON, Express Portfolio, Everyplace Geographically Dispersed, eServer, ESCON, Enterprise Storage Server, Electronic Service Agent, ECKD, e-business on demand, DS8000, DS6000, DS4000, Domino, Distributed Relational Database Architecture, DFSORT, DFSMSrmm, DFSMShsm, DFSMSdss, DFSMSdfp, DFSMS/MVS, DFSMS, DFS, developerWorks, DB2, DataPropagator, Cross-Site DB2, Cloudscape, ClearCase, CICS, Chipkill, Calibrated Vectored Cooling, C/400, Blue Gene, BladeCenter, BCOCA, Asset ID, AS/400e, AS/400, AnyNet, AIX 5L, AIX, AFS, AFP, AFCCU, Advanced Peer-to-Peer Networking, Advanced Function Printing, Advanced Function Presentation, AD/Cycle, 9406-595, 9406-570, 9406-550, 9406-520, 9405-520, 9133-55A, 9131-52A, 9124-720, 9123-710, 9119-595, 9119-590, 9118-575, 9117-570, 9116-561, 9115-505, 9113-550, 9111-520, 9111-285, 9110-51A, 9110-510, 7047-185, 7037-A50, IBM System p S-9133-1EJ, IBM System p S-9133-1EF, IBM System p S-9133-1ED, IBM System p S-9133-1EB, IBM System p S-9131-1KD, IBM System p S-9131-1KB, IBM System p S-9131-1K0, IBM System p S-9117-570S, IBM System p S-9117-570R, IBM System p S-9117-570P, IBM System p S-9117-570N, IBM System p S-9117-570M, IBM System p S-9117-570A, IBM System p S-9115-1F7, IBM System p S-9115-1F6, IBM System p S-9115-1F4, IBM System p S-9110-1M6, IBM System p S-9110-1M5, IBM System p S-9110-1M4, IBM System p 9133-55A Server, IBM System p 9133-1EJ, IBM System p 9133-1EH, IBM System p 9133-1EF, IBM System p 9133-1ED, IBM System p 9133-1EB, IBM System p 9133-1E8, IBM System p 9133-1E6, IBM System p 9133-1E4, IBM System p 9133-1E2, IBM System p 9133-1E0, IBM System p 9131-52A Server, IBM System p 9131-1KD, IBM System p 9131-1KB, IBM System p 9131-1K8, IBM System p 9131-1K6, IBM System p 9131-1K4, IBM System p 9131-1K2, IBM System p 9131-1K0, IBM System p 9119-595H, IBM System p 9119-595G2, IBM System p 9119-595G1, IBM System p 9119-595G, IBM System p 9119-595F, IBM System p 9119-595E, IBM System p 9119-595D2, IBM System p 9119-595D1, IBM System p 9119-595D, IBM System p 9119-595C2, IBM System p 9119-595C1, IBM System p 9119-595C, IBM System p 9119-595B2, IBM System p 9119-595B1, IBM System p 9119-595B, IBM System p 9119-595A, IBM System p 9119-595 Server, IBM System p 9119-590D1, IBM System p 9119-590D, IBM System p 9119-590C1, IBM System p 9119-590C, IBM System p 9119-590B1, IBM System p 9119-590B, IBM System p 9119-590A1, IBM System p 9119-590A, IBM System p 9119-590 Server, IBM System p 9118-575 Server, IBM System p 9117-MMA Server, IBM System p 9117-570W4, IBM System p 9117-570W3, IBM System p 9117-570W2, IBM System p 9117-570W1, IBM System p 9117-570W, IBM System p 9117-570T4, IBM System p 9117-570T3, IBM System p 9117-570T2, IBM System p 9117-570T1, IBM System p 9117-570T, IBM System p 9117-570S, IBM System p 9117-570R, IBM System p 9117-570P, IBM System p 9117-570N, IBM System p 9117-570M, IBM System p 9117-570L, IBM System p 9117-570K, IBM System p 9117-570J, IBM System p 9117-570I, IBM System p 9117-570H, IBM System p 9117-570G, IBM System p 9117-570F, IBM System p 9117-570E, IBM System p 9117-570D, IBM System p 9117-570C, IBM System p 9117-570B, IBM System p 9117-570A, IBM System p 9117-570, IBM System p 9117-570 Server, IBM System p 9116-561 Server, IBM System p 9116-1A3, IBM System p 9116-1A2, IBM System p 9116-1A1, IBM System p 9115-505 Server, IBM System p 9115-1F7, IBM System p 9115-1F6, IBM System p 9115-1F5, IBM System p 9115-1F4, IBM System p 9115-1F3, IBM System p 9115-1F2, IBM System p 9115-1F1, IBM System p 9113-550E, IBM System p 9113-550D, IBM System p 9113-550C, IBM System p 9113-550B, IBM System p 9113-550A, IBM System p 9113-550 Server, IBM System p 9111-520B, IBM System p 9111-520A, IBM System p 9111-520, IBM System p 9111-520 Server, IBM System p 9110-51A Server, IBM System p 9110-510D, IBM System p 9110-510C, IBM System p 9110-510B, IBM System p 9110-510A, IBM System p 9110-510 Server, IBM System p 9110-1M6, IBM System p 9110-1M5, IBM System p 9110-1M4, IBM System p 9110-1M3, IBM System p 9110-1M2, IBM System p 9110-1M1, IBM System p 7037-A50 Server, IBM System p 7037-1D2, IBM System p 7037-1D1, IBM System i 9411-100 Server, IBM System i 9407-515 Server, IBM System i 9406-MMA Server, IBM System i 9406-595 Server, IBM System i 9406-570 Server, IBM System i 9406-550 Server, IBM System i 9406-525 Server, IBM System i 9406-520 Server, IBM System i 9406-270 Server, IBM System i 9405-520 Server, IBM RS/6000 9076-T70 Server, IBM RS/6000 9076-55H Server, IBM RS/6000 9076-558 Server, IBM RS/6000 9076-557 Server, IBM RS/6000 9076-556 Server, IBM RS/6000 9076-555 Server, IBM RS/6000 9076-550 Server, IBM RS/6000 9076-50H Server, IBM RS/6000 9076-500 Server, IBM RS/6000 9076-40A Server, IBM RS/6000 9076-409 Server, IBM RS/6000 9076-408 Server, IBM RS/6000 9076-407 Server, IBM RS/6000 9076-406 Server, IBM RS/6000 9076-3BA Server, IBM RS/6000 9076-3B9 Server, IBM RS/6000 9076-3B8 Server, IBM RS/6000 9076-3B7 Server, IBM RS/6000 9076-3AA Server, IBM RS/6000 9076-3A9 Server, IBM RS/6000 9076-3A8 Server, IBM RS/6000 9076-3A7 Server, IBM RS/6000 9076-30A Server, IBM RS/6000 9076-309 Server, IBM RS/6000 9076-308 Server, IBM RS/6000 9076-307 Server, IBM RS/6000 9076-306 Server, IBM RS/6000 9076-2AA Server, IBM RS/6000 9076-2A9 Server, IBM RS/6000 9076-2A8 Server, IBM RS/6000 9076-2A7 Server, IBM RS/6000 9076-20A Server, IBM RS/6000 9076-209 Server, IBM RS/6000 9076-208 Server, IBM RS/6000 9076-207 Server, IBM RS/6000 9076-206 Server, IBM RS/6000 7015-S7A Server, IBM RS/6000 7015-S70 Server, IBM RS/6000 7015-R5U Server, IBM RS/6000 7015-R50 Server, IBM RS/6000 7015-R4U Server, IBM RS/6000 7015-R40 Server, IBM RS/6000 7015-R30 Server, IBM RS/6000 7015-R24 Server, IBM RS/6000 7015-R21 Server, IBM RS/6000 7015-R20 Server, IBM RS/6000 7015-R10 Server, IBM RS/6000 7015-99F Server, IBM RS/6000 7015-99E Server, IBM RS/6000 7015-990 Server, IBM RS/6000 7015-98B Server, IBM RS/6000 7015-980 Server, IBM RS/6000 7015-97B Server, IBM RS/6000 7015-970 Server, IBM RS/6000 7015-95E Server, IBM RS/6000 7015-951 Server, IBM RS/6000 7015-950 Server, IBM RS/6000 7015-930 Server, IBM RS/6000 7013-S7A Server, IBM RS/6000 7013-S70 Server, IBM RS/6000 7013-J50 Server, IBM RS/6000 7013-J40 Server, IBM RS/6000 7013-J30 Server, IBM RS/6000 7013-J01 Server, IBM RS/6000 7013-59H Server, IBM RS/6000 7013-595 Server, IBM RS/6000 7013-591 Server, IBM RS/6000 7013-590 Server, IBM RS/6000 7013-58H Server, IBM RS/6000 7013-581 Server, IBM RS/6000 7013-580 Server, IBM RS/6000 7013-57L Server, IBM RS/6000 7013-57F Server, IBM RS/6000 7013-571 Server, IBM RS/6000 7013-570 Server, IBM RS/6000 7013-560 Server, IBM RS/6000 7013-55L Server, IBM RS/6000 7013-550 Server, IBM RS/6000 7013-540 Server, IBM RS/6000 7013-53H Server, IBM RS/6000 7013-53E Server, IBM RS/6000 7013-530 Server, IBM RS/6000 7013-52H Server, IBM RS/6000 7013-52E Server, IBM RS/6000 7013-520 Server, IBM pSeries S-7029-6C3-2, IBM pSeries S-7029-6C3-1, IBM pSeries S-7029-6C3, IBM pSeries 7046-B50 Server, IBM pSeries 7044-270 Server, IBM pSeries 7044-170 Server, IBM pSeries 7043-270 Server, IBM pSeries 7043-260 Server, IBM pSeries 7043-240 Server, IBM pSeries 7043-150 Server, IBM pSeries 7043-140 Server, IBM pSeries 7040-681 Server, IBM pSeries 7040-671 Server, IBM pSeries 7039-651 Server, IBM pSeries 7038-6M2 Server, IBM pSeries 7029-6E3 Server, IBM pSeries 7029-6C3 Server, IBM pSeries 7029-284C, IBM pSeries 7029-280C, IBM pSeries 7029-244C, IBM pSeries 7029-240C, IBM pSeries 7029-224C, IBM pSeries 7029-220C, IBM pSeries 7029-180C, IBM pSeries 7029-140C, IBM pSeries 7029-120C, IBM pSeries 7029-110C, IBM pSeries 7028-6E4 Server, IBM pSeries 7028-6E1 Server, IBM pSeries 7028-6C4 Server, IBM pSeries 7028-6C1 Server, IBM pSeries 7026-M80 Server, IBM pSeries 7026-H80 Server, IBM pSeries 7026-H70 Server, IBM pSeries 7026-H50 Server, IBM pSeries 7026-H10 Server, IBM pSeries 7026-B80 Server, IBM pSeries 7026-6M1 Server, IBM pSeries 7026-6H1 Server, IBM pSeries 7026-6H0 Server, IBM pSeries 7025-H70 Server, IBM pSeries 7025-F80 Server, IBM pSeries 7025-F50 Server, IBM pSeries 7025-F40 Server, IBM pSeries 7025-F30 Server, IBM pSeries 7025-6F1 Server, IBM pSeries 7025-6F0 Server, IBM pSeries 7017-S85 Server, IBM pSeries 7017-S80 Server, IBM pSeries 7017-S7A Server, IBM pSeries 7017-S70 Server, IBM OpenPower S-9124-720-4, IBM OpenPower S-9124-720-3, IBM OpenPower S-9124-720-2, IBM OpenPower S-9124-720-1, IBM OpenPower S-9124-720-0, IBM OpenPower S-9123-710-1, IBM OpenPower S-9123-710-0, IBM OpenPower S1-9124-720-4, IBM OpenPower S1-9124-720-3, IBM OpenPower S1-9124-720-2, IBM OpenPower S1-9124-720-1, IBM OpenPower S1-9124-720-0, IBM OpenPower S1-9123-710-1, IBM OpenPower S1-9123-710-0, IBM OpenPower 9124-720-4, IBM OpenPower 9124-720-3, IBM OpenPower 9124-720-2, IBM OpenPower 9124-720-1, IBM OpenPower 9124-720-0, IBM OpenPower 9124-720 Server, IBM OpenPower 9123-710-1, IBM OpenPower 9123-710-0, IBM OpenPower 9123-710 Server, IBM OpenPower 9123-1C6 Server, IBM OpenPower 9123-1C5 Server, IBM OpenPower 9123-1C4 Server, IBM OpenPower 9123-1C3 Server, IBM OpenPower 9123-1C2 Server, IBM OpenPower 9123-1C1 Server, IBM OpenPower 9123-1B6 Server, IBM OpenPower 9123-1B5 Server, IBM OpenPower 9123-1B4 Server, IBM OpenPower 9123-1B3 Server, IBM OpenPower 9123-1B2 Server, IBM OpenPower 9123-1B1 Server, IBM OpenPower 9123-1A8 Server, IBM OpenPower 9123-1A7 Server, IBM OpenPower 9123-1A6 Server, IBM OpenPower 9123-1A5 Server, IBM OpenPower 9123-1A4 Server, IBM OpenPower 9123-1A3 Server, IBM OpenPower 9123-1A2 Server, IBM OpenPower 9123-1A1 Server, IBM iSeries 9406-SB3 Server, IBM iSeries 9406-SB2 Server, IBM iSeries 9406-SB1 Server, IBM iSeries 9406-S40 Server, IBM iSeries 9406-S30 Server, IBM iSeries 9406-S20 Server, IBM iSeries 9406-S10 Server, IBM iSeries 9406-890 Server, IBM iSeries 9406-870 Server, IBM iSeries 9406-840 Server, IBM iSeries 9406-830 Server, IBM iSeries 9406-825 Server, IBM iSeries 9406-820 Server, IBM iSeries 9406-810 Server, IBM iSeries 9406-800 Server, IBM iSeries 9406-740 Server, IBM iSeries 9406-730 Server, IBM iSeries 9406-720 Server, IBM iSeries 9406-650 Server, IBM iSeries 9406-640 Server, IBM iSeries 9406-620 Server, IBM iSeries 9406-600 Server, IBM iSeries 9406-250 Server, IBM iSeries 9406-170 Server, IBM IntelliStation S-9114-275, IBM IntelliStation 9114-275 Workstation, IBM IntelliStation 9114-240W, IBM IntelliStation 9114-140W, IBM IntelliStation 9114-100W, IBM IntelliStation 9112-265 Server, IBM IntelliStation 9111-290W+, IBM IntelliStation 9111-290W, IBM IntelliStation 9111-285 Workstation, IBM IntelliStation 9111-190W+, IBM IntelliStation 9111-190W, IBM IntelliStation 7047-250W, IBM IntelliStation 7047-185 Workstation, IBM IntelliStation 7047-150W, IBM Tape Drive, IBM Tape 911x-6279, IBM Tape 911x-6258, IBM Tape 911x-6120, IBM Tape 911x-5755, IBM Tape 911x-1997, IBM Tape 911x-1992, IBM Tape 911x-1991, IBM Tape 911x-1955, IBM Tape 911x-1892, IBM SCSI RAID Enablement Adapter, IBM SCSI RAID Enablement 911x-5737, IBM SCSI RAID Enablement 911x-5736, IBM SCSI RAID Enablement 911x-5728, IBM SCSI RAID Enablement 911x-5727, IBM SCSI RAID Enablement 911x-5726, IBM SCSI RAID Enablement 911x-5712, IBM SCSI RAID Enablement 911x-5711, IBM SCSI RAID Enablement 911x-5710, IBM SCSI RAID Enablement 911x-5709, IBM SCSI RAID Enablement 911x-5703, IBM SCSI RAID Enablement 911x-1976, IBM SCSI RAID Enablement 911x-1975, IBM SCSI RAID Enablement 911x-1974, IBM SCSI RAID Enablement 911x-1913, IBM SCSI RAID Enablement 911x-1912, IBM SCSI RAID Enablement 911x-1908, IBM SCSI RAID Enablement 911x-1907, IBM Power Supply, IBM Power 911x-7989, IBM Power 911x-7958, IBM Power 911x-7889, IBM Power 911x-7875, IBM Power 911x-6186, IBM Power 911x-5159, IBM Power 911x-5158, IBM Memory Upgrade, IBM Memory 911x-7896, IBM Memory 911x-7894, IBM Memory 911x-7893, IBM Memory 911x-7892, IBM Memory 911x-4498, IBM Memory 911x-4497, IBM Memory 911x-4492, IBM Memory 911x-4491, IBM Memory 911x-4490, IBM Memory 911x-4463, IBM Memory 911x-4462, IBM Memory 911x-4461, IBM Memory 911x-4460, IBM Memory 911x-4454, IBM Memory 911x-4452, IBM Memory 911x-4451, IBM Memory 911x-4450, IBM Memory 911x-4449, IBM Memory 911x-4447, IBM Memory 911x-4446, IBM Memory 911x-4445, IBM Memory 911x-4444, IBM Memory 911x-4443, IBM Memory 911x-1952, IBM Memory 911x-1951, IBM Memory 911x-1950, IBM Memory 911x-1949, IBM Memory 911x-1945, IBM Memory 911x-1942, IBM Memory 911x-1940, IBM Memory 911x-1938, IBM Memory 911x-1937, IBM Memory 911x-1936, IBM Memory 911x-1934, IBM Memory 911x-1932, IBM Memory 911x-1931, IBM Memory 911x-1930, IBM iSCSI 911x-5714, IBM iSCSI 911x-5713, IBM iSCSI 911x-1987, IBM iSCSI 911x-1986, IBM iSCSI, IBM InfiniBand Adapter, IBM InfiniBand 911x-7820, IBM InfiniBand 911x-1820, IBM InfiniBand 911x-1812, IBM InfiniBand 911x-1811, IBM InfiniBand 911x-1810, IBM InfiniBand 911x-1809, IBM Graphics Adapter, IBM Graphic 911x-2849, IBM Graphic 911x-2843, IBM Graphic 911x-2842, IBM Graphic 911x-1980, IBM Fibre Adapter, IBM Fibre 911x-6239, IBM Fibre 911x-6228, IBM Fibre 911x-5759, IBM Fibre 911x-5758, IBM Fibre 911x-5716, IBM Fibre 911x-1977, IBM Fibre 911x-1957, IBM Fibre 911x-1910, IBM Fibre 911x-1905, IBM Expansion Unit, IBM Expansion 911x-7863, IBM Expansion 911x-7862, IBM Expansion 911x-7861, IBM Expansion 911x-7818, IBM Expansion 911x-7164, IBM Expansion 911x-6594, IBM Expansion 911x-6593, IBM Expansion 911x-6592, IBM Expansion 911x-6574, IBM Expansion 911x-5795, IBM Expansion 911x-5794, IBM Expansion 911x-5791, IBM Expansion 911x-1800, IBM Ethernet Adapter, IBM Ethernet 911x-5740, IBM Ethernet 911x-5722, IBM Ethernet 911x-5721, IBM Ethernet 911x-5719, IBM Ethernet 911x-5718, IBM Ethernet 911x-5707, IBM Ethernet 911x-5706, IBM Ethernet 911x-5701, IBM Ethernet 911x-5700, IBM Ethernet 911x-4962, IBM Ethernet 911x-4961, IBM Ethernet 911x-4959, IBM Ethernet 911x-2975, IBM Ethernet 911x-2969, IBM Ethernet 911x-1990, IBM Ethernet 911x-1985, IBM Ethernet 911x-1984, IBM Ethernet 911x-1983, IBM Ethernet 911x-1982, IBM Ethernet 911x-1981, IBM Ethernet 911x-1979, IBM Ethernet 911x-1978, IBM Ethernet 911x-1959, IBM Ethernet 911x-1954, IBM DVD Device, IBM DVD 911x-5764, IBM DVD 911x-5763, IBM DVD 911x-5751, IBM DVD 911x-2640, IBM DVD 911x-2591, IBM DVD 911x-1994, IBM DVD 911x-1993, IBM DVD 911x-1903, IBM DVD 911x-1900, IBM Display 911x-3645, IBM Display 911x-3644, IBM Display 911x-3643, IBM Display 911x-3642, IBM Display 911x-3641, IBM Display 911x-3640, IBM Display 911x-3639, IBM Display 911x-3638, IBM Display 911x-3637, IBM Display 911x-3636, IBM Display, IBM Disk Drive, IBM Disk 911x-3581, IBM Disk 911x-3580, IBM Disk 911x-3579, IBM Disk 911x-3578, IBM Disk 911x-3281, IBM Disk 911x-3280, IBM Disk 911x-3279, IBM Disk 911x-3278, IBM Disk 911x-3277, IBM Disk 911x-3276, IBM Disk 911x-3275, IBM Disk 911x-3274, IBM Disk 911x-3273, IBM Disk 911x-3265, IBM Disk 911x-3264, IBM Disk 911x-3159, IBM Disk 911x-3158, IBM Disk 911x-3129, IBM Disk 911x-1973, IBM Disk 911x-1972, IBM Disk 911x-1971, IBM Disk 911x-1970, IBM Disk 911x-1969, IBM Disk 911x-1968, IBM Cable Assembly, IBM Cable 911x-8133, IBM Cable 911x-8132, IBM Cable 911x-8131, IBM Cable 911x-7802, IBM Cable 911x-7801, IBM Cable 911x-6123, IBM Cable 911x-6029, IBM Cable 911x-6008, IBM Cable 911x-6007, IBM Cable 911x-6006, IBM Cable 911x-6001, IBM Cable 911x-4278, IBM Cable 911x-4274, IBM Cable 911x-4273, IBM Cable 911x-4267, IBM Cable 911x-4263, IBM Cable 911x-4256, IBM Cable 911x-4242, IBM Cable 911x-3926, IBM Cable 911x-3925, IBM Cable 911x-3168, IBM Cable 911x-3156, IBM Cable 911x-3148, IBM Cable 911x-3147, IBM Cable 911x-3146, IBM Cable 911x-3125, IBM Cable 911x-3124, IBM Cable 911x-2936, IBM Cable 911x-2459, IBM Cable 911x-2456, IBM Cable 911x-2425, IBM Cable 911x-2118, IBM Cable 911x-2114, IBM Cable 911x-1839, IBM Cable 911x-1836, IBM Cable 911x-1835, IBM Async Adapter, IBM Async 911x-8137, IBM Async 911x-8136, IBM Async 911x-6312, IBM Async 911x-5723, IBM Async 911x-2947, IBM Async 911x-2944, IBM Async 911x-2943, IBM SCSI RAID 7311-5737, IBM SCSI RAID 7311-5736, IBM SCSI RAID 7311-5712, IBM SCSI RAID 7311-5703, IBM SCSI RAID 7040-5737, IBM SCSI RAID 7040-5736, IBM SCSI RAID 7040-5711, IBM SCSI RAID 7040-5710, IBM SCSI RAID, IBM Power 7031-6261, IBM Power, IBM iSCSI 7311-5714, IBM iSCSI 7311-5713, IBM iSCSI 7040-5714, IBM iSCSI 7040-5713, IBM iSCSI, IBM InfiniBand 7311-1820, IBM InfiniBand 7040-1820, IBM InfiniBand, IBM I/O Tower 7031-T24, IBM I/O Drawer 7311-D20, IBM I/O Drawer 7311-D11, IBM I/O Drawer 7311-D10, IBM I/O Drawer 7040-61D, IBM I/O Drawer 7031-D24, IBM Graphics 7311-2849, IBM Graphics 7040-2849, IBM Graphics, IBM Fibre 7311-6239, IBM Fibre 7311-6228, IBM Fibre 7311-5759, IBM Fibre 7311-5758, IBM Fibre 7311-5716, IBM Fibre 7040-6239, IBM Fibre 7040-6228, IBM Fibre 7040-5759, IBM Fibre 7040-5758, IBM Fibre 7040-5716, IBM Fibre, IBM Expansion 7031-5742, IBM Expansion 7031-5741, IBM Expansion, IBM Ethernet 7311-5740, IBM Ethernet 7311-5722, IBM Ethernet 7311-5721, IBM Ethernet 7311-5719, IBM Ethernet 7311-5718, IBM Ethernet 7311-5707, IBM Ethernet 7311-5706, IBM Ethernet 7311-5701, IBM Ethernet 7311-5700, IBM Ethernet 7311-4962, IBM Ethernet 7311-4961, IBM Ethernet 7040-5740, IBM Ethernet 7040-5722, IBM Ethernet 7040-5721, IBM Ethernet 7040-5719, IBM Ethernet 7040-5718, IBM Ethernet 7040-5707, IBM Ethernet 7040-5706, IBM Ethernet 7040-5701, IBM Ethernet 7040-5700, IBM Ethernet 7040-4962, IBM Ethernet 7040-4961, IBM Ethernet 7040-2975, IBM Ethernet 7040-2969, IBM Ethernet, IBM Disk 7311-3578, IBM Disk 7311-3279, IBM Disk 7311-3278, IBM Disk 7311-3277, IBM Disk 7311-3275, IBM Disk 7311-3274, IBM Disk 7311-3273, IBM Disk 7040-3578, IBM Disk 7040-3279, IBM Disk 7040-3278, IBM Disk 7040-3277, IBM Disk 7040-3275, IBM Disk 7040-3159, IBM Disk 7040-3158, IBM Disk 7031-3578, IBM Disk 7031-3279, IBM Disk 7031-3278, IBM Disk 7031-3277, IBM Disk 7031-3275, IBM Disk 7031-3274, IBM Disk, IBM Async 7311-5723, IBM Async 7040-5723, IBM Async, IBM I/O Drawer, IBM VX3 Tape Drive 7212-1114, IBM VX3 Tape Drive 7206-VX3 Warning : [Minor] Extracted only 1000 dc:subject items. Ignore minor errors to extract all Caption Writer : GST, Inc. - IBM System p, p5, pSeries, RS/6000, System i, i5, iSeries, AS/400, OpenPower and TotalStorage Experts. Authors Position : GST, Inc. - http://www.gstinc.com/store/IBM-C552.aspx Marked : False Has XFA : No Page Count : 110 Page Layout : SinglePage Language : EN-US Author : GST, Inc. - http://www.gstinc.com/store/IBM-C552.aspxEXIF Metadata provided by EXIF.tools