               ILR Series i-Q310 Transponders Models CST/SET/ATR/LPT/DRT/ATN  Installation and Operation Manual
  Page 2 of 23  i-Q 310 ISO 18000-7 Transponder Series Proprietary Notice This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or disclosed to other parties in whole or in part without prior written authorization from IDENTEC SOLUTIONS. Disclaimer and Limitation of Liability IDENTEC SOLUTIONS AG and its affiliates, subsidiaries, officers, directors, employees and agents provide the information contained in this Manual on an “as-is” basis and do not make any express or implied warranties or representations with respect to such information including, without limitation, warranties as to non-infringement, reliability, fitness for a particular purpose, usefulness, completeness, accuracy or up-to-datedness. IDENTEC SOLUTIONS shall not in any circumstances be liable to any person for any special, incidental, indirect or consequential damages, including without limitation, damages resulting from use of or reliance on information presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in advance of the possibility of such damages. Trademarks “IDENTEC SOLUTIONS”,  “Intelligent Long Range”, “ILR” and the stylized “i” are registered trademarks and “i-Q”, “i-D”, “i-B”, “i-CARD”, “i-PORT”, “i-LINKS”, “Solutions. It’s in our name.”, “Smarten up your assets” are trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS AG. Copyright Notice Copyright © 2009 IDENTEC SOLUTIONS. All rights reserved. No part of this document may be reproduced or transmitted in any form by any means, photographic, electronic, mechanical or otherwise, or used in any information storage and retrieval system, without the prior written permission of IDENTEC SOLUTIONS.    Reg. No. IM.0782.EN Order Code: Issue 0 / June 2009 – 05. October 2009 –  IDENTEC SOLUTIONS, Inc.  Liberty Plaza II, Suite 375 5057 Keller Springs Rd, Addison, Texas 75001 USA Tel: (972) 535 4144, Fax: (469) 424-0404, Toll Free: 1 866 402 4211 info@identecsolutions.com www.identecsolutions.com  Subject to alteration without prior notice. © Copyright IDENTEC SOLUTIONS 2009 Printed in Germany
  Page 3 of 23  i-Q 310 ISO 18000-7 Transponder Series  Radio Frequency Compliance Statement  IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices:  MODELS:  i-Q310 CST, i-Q310 SET, i-Q310 ATR, i-Q310 LPT, i-Q310, i-Q310 DRT, i-Q310 ATN EUROPE:  CE  USA  FCC, HERO Canada  Industy Canada  USA:      FCC ID OO4-IQ310 for Models i-Q310 SET, i-Q310 ATR, i-Q310 LPT, i-Q310 DRT       FCC ID OO4-IQ310CST for Model i-Q310 CST       FCC ID OO4-IQ310ATN for Model i-Q310 ATN Industry Canada:   IC:3538A-IQ310 for Models i-Q310 SET, i-Q310 ATR, i-Q310 LPT, i-Q310 DRT       IC:3538A-IQ310CST for Model i-Q310 CST       IC:3538A-IQ310ATN for Model i-Q310 ATN HERO:  The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.   European Notification according R&TTE Directive  This equipment complies to Art. 6.4 of R&TTE Directive (1999/5/EC). It is tested for compliance with the following standards: ETSI EN 300 220, ETSI EN 301 489, EN 60950  USA Notification This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  The device has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
  Page 4 of 23  i-Q 310 ISO 18000-7 Transponder Series        Safety Precautions  Important Safety Notes The system described in this manual is for exclusive operation by trained employees. Only qualified personnel that know the potential dangers involved should perform the installation, settings, maintenance and repair of the units used.  On account of high operating temperature of 80°C (+176°F) care must be taken, if the tags are heated. To avoid burn wait a while until the tags have cooled down or use gloves. At temperatures below 0°C (+32°F) tags can be iced. In this case, wait a while until tags are warmed up or use gloves.   The models i-Q310 SET, i-Q310 CST, i-Q310 ATR, i-Q310 LPT and i-Q310 DRT contain replaceable battery. Due to UL safety clauses this battery must be replaced only by skilled personnel. See also chapter  Battery Replacement Procedure.  All tags contain a battery. That is the reason for the following instructions:  CAUTIONCAUTIONCAUTIONCAUTION    RISK OF EXPLOSION IF BATTERY IS REPLACEDRISK OF EXPLOSION IF BATTERY IS REPLACEDRISK OF EXPLOSION IF BATTERY IS REPLACEDRISK OF EXPLOSION IF BATTERY IS REPLACED    BY AN INCORRECT TYPE.BY AN INCORRECT TYPE.BY AN INCORRECT TYPE.BY AN INCORRECT TYPE.    DISPOSE OF USED BATTERIES ACCORDINGDISPOSE OF USED BATTERIES ACCORDINGDISPOSE OF USED BATTERIES ACCORDINGDISPOSE OF USED BATTERIES ACCORDING    TO THE INSTRUCTIONSTO THE INSTRUCTIONSTO THE INSTRUCTIONSTO THE INSTRUCTIONS Operational Safety The correct and safe use of these systems assumes that operating and service personnel follow the safety measures described in the manual alongside the generally acceptable safety procedures. If there is a possibility that safe operation cannot be guaranteed the system must be switched off and secured against accidental use. Then the service unit responsible must be informed.  Electrostatic Discharge  This product contains components that are sensitive to electrostatic discharges. Please observe the special instructions for their protection. Incorrect handling can damage the unit and cause the invalidation of the warranty.  Safety Documents This ILR system was designed, tested and supplied in perfect condition according to document  testreport EN60950. Condensation/Change of Temperature Moving the systems from a cold to a warm environment could lead to dangerous situations due to condensation. Therefore it must be ensured that the system can adjust itself to the warmer temperature. Spare Parts We recommend that only original products, spare and replacement parts authorized by IDENTEC SOLUTIONS be used for installation, service and repair. Otherwise IDENTEC SOLUTIONS does not accept any responsibility for materials used, work carried out or possible consequences.
  Page 5 of 23  i-Q 310 ISO 18000-7 Transponder Series Contents 1 INTRODUCTION ...........................................................................................................6 1.1 I-Q310 SERIES TRANSPONDER FUNCTIONALITY......................................................................6 1.2 CST AND SET FEATURES AND BENEFITS...............................................................................6 2 TECHNICAL SPECIFICATIONS......................................................................................7 3 TRANSPONDER DESCRIPTION.....................................................................................8 3.1 HOUSING......................................................................................................................8 3.2 TRANSPONDER DATA MEMORY............................................................................................9 3.3 USB INTERFACE .............................................................................................................9 3.4 BATTERY INSTALLATION AND POWER UP INDICATION ..............................................................10 4 INSTALLATION...........................................................................................................11 4.1 SET MOUNTING OPTIONS...............................................................................................11 4.2 MOUNTING THE SET TRANSPONDER ..................................................................................12 4.3 MOUNTING THE CST TRANSPONDER...................................................................................13 4.4 TRANSPONDER ENCLOSURE PROTECTION .............................................................................14 5 INITIAL OPERATION..................................................................................................15 5.1 ACTIVATING THE TRANSPONDER .......................................................................................15 5.1.1 How to Activate the Transponder ...............................................................................15 5.1.2 Battery Replacement Procedure..................................................................................16 5.1.3 CST/SET LED description and operation......................................................................17 5.1.3.1 Sensor LEDs......................................................................................................................... 17 5.1.3.2 Light Sensor input................................................................................................................. 17 5.1.3.3 Push Button ......................................................................................................................... 17 5.1.3.4 Humidity Sensor input...........................................................................................................17 5.1.3.5 BAT power LED..................................................................................................................... 18 5.2 CONFIGURATION...........................................................................................................18 6 USB OPERATION ........................................................................................................19 6.1 USING THE USB CONNECTION..........................................................................................19 6.2 DISCONNECTING THE USB CONNECTION.............................................................................19 7 MAINTENANCE AND TROUBLESHOOTING .................................................................21 7.1 TROUBLESHOOTING .......................................................................................................21 7.2 TRANSPONDER BATTERY .................................................................................................21 7.2.1 Replacing the Transponder’s Battery...........................................................................21 7.3 RETURNS ....................................................................................................................22 8 ASSOCIATED DOCUMENTS.........................................................................................23
  Page 6 of 23  i-Q 310 ISO 18000-7 Transponder Series 1 Introduction 1.1  i-Q310 Series Transponder Functionality The i-Q ISO 18000-7 transponders are high performance active RFID devices suitable for a wide variety of applications. The transponder responds to interrogator commands over the distance of 100 (and more) meters in line of sight. The transponders have a battery with a typical operational life of 3 or more years. This battery is easily replaceable in most models (ATR, DRT, LPT, SET and CST) for prolonged life span.  The exception is the ATN transponder that has a non-removable sealed battery.    The i-Q310 series includes the following transponders: • i-Q310 ATR = Asset Transponder  • i-Q310 ATN = Asset Transponder with Non-Replaceable Battery described on page 20 • i-Q310 DRT = Data Rich Transponder • i-Q310 LPT = License Plate Transponder • i-Q310 SET = Sensor Transponder  • i-Q310 CST = Container Security Transponder  For description and instructions for ATR, ATN, DRT and LPT Transponders, please see a separate i-Q310 Series Installation and Operation Manual for ATR, ATN, DRT and LPT. 1.2 CST and SET Features and Benefits  100-meters (300 ft) read/write range allows automated identification, tracking and tracing of assets without human intervention.  The CST and SET transponders offer two memory areas.   o The SET and CST have 128kB of memory allocated for user data o The SET and CST have 32 bits of memory allocated for a fixed, unique, Identification Code.  o The SET and CST have 32kB of memory allocated for sensor logging.   433 MHz operating frequency allows low-power, long communication range and high data transmission rates with minimal interference due to local conditions.  ISO / IEC 18000-7 compatible allows manufacturer independent interoperation. US DoD and NATO ITV compatible.    All transponders carry a speaker for acoustic signalization during search, locate, alarms.  The CST and SET transponders provide USB 2.0 Hardwire Interface for fast and secure data transfer with USB connection with mini-B connector.  3-year battery lifetime and more delivers long-time maintenance-free operation, without battery replacement.  CST and SET transponders have a replaceable battery for extended lifetime.  Communication on demand eliminates RF flooding through software-controlled read/write operations.  Non-line-of-sight data transmission allows tags to be buried while transmitting for improved tracking and tracing efficiency.
   i-Q310 ISO 18000-7 Transponder Series  Page 7 of 23 2 Technical Specifications  Performance  Read rate    Up to 100 tags/s (Collect Tag Identification Code only) Max. response time    < 150 ms (single tag)  RF Communication  Read range    Up to 100 m (300 feet) @ free air Write range    Up to 100 m (300 feet) @ free air Operating frequency    433.92MHz Data rate (download to tag)   27.778 Kbits/s Data rate (upload to reader)   27.778 Kbits/s Frequency    433.92MHz international ISM band Modulation    FSK ± 50 kHz at 27.778 kHz data rate Sensitivity    -85dBm / range at least 300ft (~100m) Maximum transmission power  1mW– comply with national regulations Standard / Certification    ISO/IEC 18000-7  Hardwire Communication   Standard               USB 2.0 Connector               Mini-B  Electrical  Power source      Lithium battery (replaceable, except ATN) Expected battery life    Typically 3 years and more depending on usage Battery monitoring    Yes  Data Data retention    >10 years without power Write cycles    100,000 writes to a tag  Memory size    128k bytes/32k bytes Identification code    32 bit fixed ID  Environmental  Operating temperature    –40°C to +80°C (–40ºF to +176ºF) Humidity        10% to 90% relative humidity at 30°C (+86ºF) Shock    50 G, 3 times DIN IEC 68-2-27 Multiple drops to concrete from 1 m (3 ft)  Vibration  3 G, 20 sine wave cycles, 5 Hz to 150 Hz,  DIN IEC 68-2-6 5 G, noise 5 Hz to 1000 Hz, 30 minutes  DIN IEC 68-2-64 Physical  Dimensions (CST)  7 in. length x 4.24 in. width x 3.97 in height.  (17.7 cm x 10.7 cm x 10 cm) Weight (CST)  200 g (7 oz) Dimensions (SET) with bracket   6.25 in. length x 2.15 in. width x 1.75 in. height (15cm x 5.5 cm x 4.5 cm) Dimensions (SET) without bracket  5.76 in length x  2.17 in width x 1.53 in height (14.6 cm x 5.5 cm  x 3.9 cm Weight (SET)  100 g (3.52 oz) Enclosure  Plastic (ASA / Luran® S) Enclosure rating  IP 65
   i-Q310 ISO 18000-7 Transponder Series  Page 8 of 23 3 Transponder Description 3.1 Housing The SET and CST i-Q310 transponders are made of a rugged plastic housing with IP 65 rating. On the front side (see Fig. 3.1 and 3.2) there are identification labels, which provide information about the type of the tag, the tag manufacturer and prime contractor, certifications, barcode and the IAW MIL-Std-129P markings where appropriate. On the rear side of the transponder, there are brackets with openings for transponder mounting and for clip-on magnetic mounts.  The SET and CST transponders have identical front panel markings, sensors, and LEDs.     Figure 3.1 Front view of the SET transponder   Product label  Sensor LEDs  Light Sensor input  Push Button  Humidity Sensor input  USB cover  Battery cover
   i-Q310 ISO 18000-7 Transponder Series  Page 9 of 23  Figure 3.2  Front view of the CST transponder  3.2 Transponder Data Memory The CST and SET models of the i-Q310 series transponders offer 128 kBytes of non-volatile memory for general purpose and user data.  In addition, 32kBytes of non-volatile memory is available for sensor logging.    3.3 USB Interface The transponders are enabled for fast and secure data transfer using USB connection with mini-B connector. The USB connector is placed next to the battery cap under a separate cover (Fig. 3.3).
   i-Q310 ISO 18000-7 Transponder Series  Page 10 of 23  Figure 3.3  USB connector  3.4 Battery installation and power up indication  The transponder ships with the battery reversed; please see Chapter 5 for details on how to power and activate the transponder.
   i-Q310 ISO 18000-7 Transponder Series  Page 11 of 23 4 Installation 4.1 SET Mounting Options The transponders are designed with two mounting holes so they can be firmly mounted onto virtually any surface. The transponder can be mounted using various methods dependent on the particular application. Among the common types of mounting are:  • Screws  • Rivets  • Double sided tape  • Wire ties • Mounting bracket (Fig. 4.1 and 4.2) • Magnetic mount (Fig. 4.3)   Figure 4.1  The SET mounting bracket   Figure 4.2  Installing the SET transponder into the bracket
   i-Q310 ISO 18000-7 Transponder Series  Page 12 of 23   Figure 4.3  Magnetic mount installation for the SET   4.2 Mounting the SET Transponder The transponder has slots that allow mounting using wire ties without the mounting bracket. The mounting bracket has also openings in order to be wire tied to a post or other object (Fig 2.4).     Figure 4.4 SET Mounting with wire ties
   i-Q310 ISO 18000-7 Transponder Series  Page 13 of 23 4.3 Mounting the CST transponder The CST is intended for ISO shipping containers like the one shown below in Fig 4.5.     Figure 4.5 ISO container (typical)   The CST transponder is shown below mounted in various orientations.  The ISO door mount opening on the CST is 55mm (2.17”) shown in Figure 4.6.  It must be mounted on the left door with the antenna outside the container and the sensor body and switch mounted inside the container, shown in Figs 4.8 and 4.9.  The roller switch arm shown in Fig 4.6 and 4.8 should contact the right door to detect a breach or opening of the door.   Figure 4.6 CST door mount opening
   i-Q310 ISO 18000-7 Transponder Series  Page 14 of 23  Figure 4.7 CST inside left door mounting    Figure 4.8 CST inside left door mounting 4.4 Transponder enclosure protection The CST and SET transponders all have enclosures rated at IP 65.  This means that the transponders are dust tight and water tight.  However care should be taken to not immerse in liquids or subject to powerful jets of water.   The transponder casing should not be opened at any time in order to preserve the integrity of the IP 65 rating and maintain the factory seal.   Figure 4.9  Transponder seal
   i-Q310 ISO 18000-7 Transponder Series  Page 15 of 23 5 Initial Operation 5.1 Activating the Transponder The i-Q310 ISO 18000-7 transponders needs to be activated. They are shipped with a reversed battery to prevent communication and battery consumption (Fig. 5.1).   Figure 5.1  Battery shown reversed with  the negative (-) terminal shown. 5.1.1 How to Activate the Transponder  Before use, the battery cover has to be opened, battery flipped over and securely closed. This activates the transponder for operation. Use only A size 3.6 V Lithium Li-SOCl2 batteries.    Figure 5.2  Battery shown in correct orientation with  the positive (+) terminal shown.
   i-Q310 ISO 18000-7 Transponder Series  Page 16 of 23 5.1.2 Battery Replacement Procedure   Before starting battery replacement regard following instructions:   1.  Due to UL safety clauses this battery must be replaced only by skilled personnel.   2.  Warning     Fire, explosion and burn hazard          Risk of explosion if battery is replaced by an incorrect type     Do not recharge, short circuit, crush, disassemble, heat above 100°(212°F)          Do not incinerate, or expose contents to water  3.  Use only  3.6 V Lithium Li-SOCl2 batteries, and only type: Saft LS 17500    4.  Do not replace the battery or open the battery compartment outdoors or in cold or moist                    environment. Always replace it in a warm and dry place. If the tag has been brought  from a         cold (less than 10 °C/50 °F) into a warm environment it should warm up for 1 hour.   5.  Do not dispose used batteries into household waste. Used batteries are hazardous waste.        1. Remove the battery cover by rotating counter clockwise while slightly depressing cover (Fig 5.3).                    Figure 5.3 Opening the Battery Cap  2. Remove the battery and put it back with the poles reversed (Fig. 5.2). The ⊕ should point out.  3. Replace the battery cover by rotating it clockwise while slightly depressing it. 4. When you hear a short beep, the transponder is activated and ready for operation (see section 5.1.3).  5. If no beep is heard, either the battery is not oriented correctly or it needs to be replaced.  6. Follow steps 2 – 4 for battery replacement in case of depletion.    Note: To keep moisture and dust out of the transponder take care to not lose the o-ring seal on the battery cover or to leave the battery cover off the transponder for extended periods.
   i-Q310 ISO 18000-7 Transponder Series  Page 17 of 23   5.1.3 CST/SET LED description and operation    Figure 5.4  LED indicators and sensor inputs  5.1.3.1 Sensor LEDs The sensor LEDs are illuminated when……….??? 5.1.3.2 Light Sensor input  Need description for content 5.1.3.3 Push Button Need description for content 5.1.3.4 Humidity Sensor input Need description for content Light Sensor    Push Button    Humidity Sensor
   i-Q310 ISO 18000-7 Transponder Series  Page 18 of 23 5.1.3.5 BAT power LED The SET and CST transponders have an LED for battery status as indicated in Fig 5.4. If the battery has more than a 15% charge remaining the LED will be green.  Below this level the battery warning flag is set in memory, and the LED will illuminate red.  The battery LED will be off when the battery charge is depleted or not installed.  5.2 Configuration The i-Q310 series transponders are not configured directly. They are configured using the i-PORT F310 device via the air interface and appropriate software. Please see the FDU and Handheld User’s Guide for information on how to configure transponders.
   i-Q310 ISO 18000-7 Transponder Series  Page 19 of 23 6 USB Operation Important Note While a transponder is connected via USB to a PC it is continuously powered by the internal battery. In order to save battery life, please close the USB connection and remove the transponder from the USB connection after data transfer.  On account of high operating temperature only use usb cable specified up to +80°C (+176°F). Recommended cable is Kabeltronic Bestell Nr. 1918010. This cable is specified from -20°C to +80°C. For that reason USB is not usable at temperatures below -20°C.  6.1 Using the USB Connection Please see the FDU Software Manual for details.  6.2 Disconnecting the USB Connection As the transponder is not operating as a USB mass storage device with buffers that must be flushed before removal, it is quite easy to disconnect it from the USB connection:  • Stop the service software or cancel the connection to the transponder in the service software. • Remove the transponder from the USB connection. • Protect the USB connector by safely tightening the protective rubber lid of the transponder.
   i-Q310 ISO 18000-7 Transponder Series  Page 20 of 23 Asset Tag i-Q310 ATN    The i-Q310 series of tags is IDENTEC SOLUTIONS’ well-established generation of Intelligent Long Range (ILR) active RFID tags based on the ISO 18000-7 standard.  ILR provides highly accurate, real-time data collection without human intervention in wireless applications such as: Identification, tracking and tracing. Using advanced UHF radio frequency technology, i-Q310 ATN tags transmit and receive data at distances of up to 100 meters (300 feet). The standardized anti-collision multi-tag-handling algorithm allows communication to tags even when thousands of tags are within the interrogator's read zone. The tag has very thin profile to fit in very small spaces. Because of its very low power consumption, the tag can operate effectively for over 3 years.  Integrated speaker supports acoustic signalization during search, locate and alarms. The i-Q310 tag line can withstand the abuse expected from work processes; the tags are very economical and an ideal fit for high volume tracking of assets.  Features Benefits  100-meters (300 ft) read/write range  Allows automated identification, tracking and tracing of assets without human intervention.  2 kBytes memory  Stores 2 kBytes of user data.   433 MHz operating frequency  Allows low-power, long communication range and high data transmission rates with minimal interference due to local conditions.  ISO/IEC 18000-7 compatible  Manufacturer independent interoperation. US DoD and NATO ITV compatible.    Speaker   Acoustic signalization during search, locate, alarms.  3-year battery lifetime and more  Delivers long-time maintenance-free operation, without battery replacement.  Dormant Mode  The tag can be set to a non-responsive mode.  Communication on demand only  Eliminates RF flooding through software-controlled read/write operations.  Non-line-of-sight data transmission  Allows tags to be buried while transmitting for improved tracking/locating efficiency.   Thin Profile  The smaller dimensions make the tag perfect for tight spaces.  Low cost  Economical tracking of large quantities of assets using high-performance active technology.
   i-Q310 ISO 18000-7 Transponder Series  Page 21 of 23 7 Maintenance and Troubleshooting 7.1 Troubleshooting  The transponder does not respond to interrogation at all. • Make sure the battery is inserted in a correct orientation. • Make sure the battery is not depleted. Change the battery. • Tighten the battery cap in order to ensure that both poles are in contact with the transponder’s circuits.  The transponder is not accessible through USB. • Ensure that the USB cable is tightly plugged into the transponder and the host PC. • Switch the USB cable. • Are the correct drivers installed, communication configured? Please refer to the FDU Software User’s Manual.  Other issues: If none of the above steps resolved the issue or there are other issues with the transponder not mentioned here, please contact technical support.  7.2 Transponder Battery The battery of the transponder has a typical lifetime expectancy of more than 3 years. A depleted battery can be replaced with a new one. 7.2.1 Replacing the Transponder’s Battery For steps on how to replace the battery, please see Chapter 5. Safety Instructions  Do not replace the battery or open the battery compartment outdoors or in cold or moist environment. Always replace it in a warm and dry place. If the transponder has been brought from a cold (less than 10 °C/50 °F) into a warm environment it should warm up for 1 hour.  Replace the battery only with a type provided by or recommended by IDENTEC SOLUTIONS.  The battery has to be disposed as special refuse.  Important Note If the battery is replaced after the transponder has signaled a “battery low” status, simply replace the battery following the description in advance. The transponder will automatically recognize the battery exchange and will automatically reset its battery usage counter.  If the battery is replaced on a regular precautionary basis without the “battery low” signal, after replacing the battery, the transponder needs a service command in order to reset its battery usage counter.
   i-Q310 ISO 18000-7 Transponder Series  Page 22 of 23  7.3 Returns  Parts or main components returned for repair or exchange must be handled with great care. All returns should include a completed returns form (see appendix) and be sent to:  IDENTEC SOLUTIONS, Inc. 5057 Keller Springs Rd., Ste 375 Addison, TX 75001 USA
   i-Q310 ISO 18000-7 Transponder Series  Page 23 of 23 8 Associated Documents Manuals IM.0780.EN  System Description, English IM.0781.EN  i-PORT F310 Hardware and Installation Manual, English IM.0782.EN  i-Q310 Series Transponder Installation and Operation Manual for ATN, ATR, DRT and LPT, English  IM.0783.EN  i-PORT H310 Handheld Interrogator Module, English  Data Sheets ID.0680.EN  i-PORT F310, English ID.0681.EN  i-Q310 ATN—Asset Transponder, English ID.0682.EN  i-Q310 ATR—Asset Transponder, English ID.0683.EN  i-Q310 DRT—Data Rich Transponder, English ID.0684.EN  i-Q310 SET—Sensor Transponder, English ID.0685.EN  i-Q310 LPT—License Plate Transponder, English ID.0686.EN  i-Q310 CST—Container Security Transponder, English ID.0689.EN  i-PORT H310 Handheld Interrogator Module, English