Identiv TSCTYMU-02 Secure RFID Physical Access Terminal User Manual

Identiv, Inc Secure RFID Physical Access Terminal

Users Manual

Download: Identiv TSCTYMU-02 Secure RFID Physical Access Terminal User Manual
Mirror Download [FCC.gov]Identiv TSCTYMU-02 Secure RFID Physical Access Terminal User Manual
Document ID2024751
Application IDTbjeTGj4HFm1Anc+P89CyA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize38.25kB (478121 bits)
Date Submitted2013-07-24 00:00:00
Date Available2013-08-02 00:00:00
Creation Date2013-07-19 14:47:27
Producing SoftwareAdobe PDF Library 10.0
Document Lastmod2013-07-19 14:47:38
Document TitleDocument Template
Document CreatorAcrobat PDFMaker 10.1 for Word
Document Author: Sixtus

TouchSecure® Connectivity User Manual
Ver2.0
TouchSecure® Connectivity User Manual
Version History
Date
16-May-13
11-Jul-13
Version
1.0
2.0
Description of Changes
Initial version
1. ICES-003 Statement removed.
2. French translation added for RSS-GEN
3. Added FCC statement
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Author
Sixtus
Sixtus
Page 2 of 11
Internal Use Only
TouchSecure® Connectivity User Manual
Contents
1.0
Introduction ................................................................................................................................ 4
2.0
Reader ......................................................................................................................................... 4
2.1
2.2
2.3
Functionality.............................................................................................................................. 4
Top Casing ............................................................................................................................... 4
TouchSecure® reader with Bottom Casing .............................................................................. 5
3.0
Product details ........................................................................................................................... 5
4.0
Specifications ............................................................................................................................. 6
5.0
Installation details ...................................................................................................................... 6
5.1
Parts List ................................................................................................................................... 6
5.2
Recommended Infrastructure ................................................................................................... 6
5.3
Wiring Information..................................................................................................................... 6
5.3.1
Cable Color codes for Pig Tail Reader .............................................................................. 6
5.3.2
Pin out for Phoenix Connector Reader ............................................................................. 7
5.4
Mounting the Reader ................................................................................................................ 8
5.4.1
Location of mounting holes on wall ................................................................................... 8
5.4.2
Reader Installation Steps .................................................................................................. 8
5.5
Power up and Testing ............................................................................................................. 10
6.0
6.1
6.2
6.3
Certifications ............................................................................................................................ 10
FCC ........................................................................................................................................ 10
IC ............................................................................................................................................ 10
CE ........................................................................................................................................... 11
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Page 3 of 11
Internal Use Only
TouchSecure® Connectivity User Manual
1.0 Introduction
This document details the Physical Access Control Reader TouchSecure® and its basic operational
and installation procedures. It covers the details of the Mullion form-factor reader
Model: Connectivity MUL
The reader comes in two variants for interfacing with the control panel
•
•
Pigtail
Phoenix connectors
2.0 Reader
2.1
Functionality
TouchSecure® is a physical access reader that can read HF and LF contactless credentials .The
reader can interface with an access control system equipped with a Wiegand or RS485 serial
interface Control Panel. It can also be interfaced with a Host Sever / Control Panel that supports
Ethernet interface. User interfaces include RGB LED’s and Buzzer.
The reader consists of the following main parts.
2.2
Top Casing
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Page 4 of 11
Internal Use Only
TouchSecure® Connectivity User Manual
2.3
TouchSecure® reader with Bottom Casing
3.0 Product details
Model Name
: Connectivity MUL
Device Type
: RFID reader, 13.56MHz (HF) / 125 KHz (LF)
Physical Access control Reader (accessory equipment)
Type of equipment
: Potted reader. Suitable for Indoor / Controlled Outdoor use
Interface Type
: Pigtail Cable (11 Core + Drain) or Phoenix connectors and RJ45
Voltage Rating
: 5-16V DC or 48VDC on RJ45 Connector
Current Rating @12V
: Pk Current – 180mA , Average Current 120mA
Communication protocol
: Wiegand, RS485 (2wire - Half Duplex) , 10BaseT ETH
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Page 5 of 11
Internal Use Only
TouchSecure® Connectivity User Manual
4.0
Specifications
Model
Op Voltage
Current @ 12V
Op temp
Cable Length
Connectivity MUL
5-16 VDC or
POE@ 48VDC
Av -120mA
Pk -180mA
-35 to +65 Deg C
RS485 - 4000ft (24AWG)
Wiegand -500ft (22AWG)/
300ft (24AWG)
Table 1
5.0 Installation details
5.1
Parts List
•
•
•
•
TouchSecure®reader -1
Screws (A #6-18X1.5" SS ) - 2Nos – Mounting screws for Wall
Snake Eye Screw (SMF #6-32X5/16" SS) – 1 No- Top casing mounting security screw
Screws (SMF #6-32x3/8" SS) - 3 No’s - 1 Top casing mounting screw and 2 Junction Box
mounting screws
Nylon anchor plug -2 Nos
6 pin phoenix plug (Phoenix connector version only) – 2 Nos
•
•
5.2
Recommended Infrastructure
•
•
•
•
•
Cable Wiegand
Cable RS485
Cable RJ45
Linear DC PS
POE Adaptor Kit
- 22AWG for 500Ft / 24AWG for 300Ft with Foil Shield
- RS485 for 1000m** (4000ft) 24AWG STP
- Cat5e / Cat6
- 5-16 V, 1A min.
- TL-POE200A
** Tested in lab conditions upto 115Kbaud
5.3
Wiring Information
5.3.1
Cable Color codes for Pig Tail Reader
Red
Black & White
Green
White
Orange
Yellow
Blue
Brown
Grey
Pink
Violet
Black / Drain
+ VDC 12V (nominal)
Ground
Wiegand Data 0
Wiegand Data 1
LED Green
Buzzer
Hold
LED Red
RS485 RS 485 +
Tamper Output
Shield Ground
Table 2
&-
Do not connect when reader is powered by Power over Ethernet
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Page 6 of 11
Internal Use Only
TouchSecure® Connectivity User Manual
5.3.2
Pin
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
P2.1
P2.2
P2.3
P2.4
P2.5
P2.6
Pin out for Phoenix Connector Reader
Cable colour
Orange
White
Green
Black
Black + White
Red
Blue
Violet
Gray
Pink
Yellow
Brown
Description
LED Green
Data 1
Data 0
Drain
Gnd
Power
Hold
Tamper
RS485RS485+
Buzzer
LED Red
Comment
Do not connect when reader is powered by PoE
Table 3
Caution:
During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might
affect reader functionality/ cause damage to the reader.
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Page 7 of 11
Internal Use Only
TouchSecure® Connectivity User Manual
5.4
Mounting the Reader
5.4.1
Location of mounting holes on wall
Phoenix connector Reader – 2 Holes and 1 Slot
5.4.2
Reader Installation Steps
a.
b.
c.
d.
Make two holes on the wall as per the image above.
Insert the nylon screw plugs into the wall.
Connect the wires as per the Table 2 or Table 3.
TouchSecure® reader with Bottom Casing is to be now secured onto the wall using the
Screws (A #6-18X1.5" SS )
e. The top casing can be inserted onto the bottom casing
f. Secure the Top and bottom casing by the Snake Eye Screw (SMF #6-32X5/16" SS)
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Page 8 of 11
Internal Use Only
TouchSecure® Connectivity User Manual
Reader Installation Steps - Phoenix Connector Version
Reader Installation Steps - Pig Tail Version
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Page 9 of 11
Internal Use Only
TouchSecure® Connectivity User Manual
5.5
Power up and Testing
Turn power on
The LED blinks 3 times green with a long beep, then turns red
Present a card
The LED blinks green, and a short Beep is emitted
This is the default reader behavior.
6.0 Certifications
6.1
FCC
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
Information to user
Changes or modifications not expressly approved by Identive could void the user's authority
to operate the equipment.
6.2
IC
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Page 10 of 11
Internal Use Only
TouchSecure® Connectivity User Manual
6.3
CE
Identive hereby declares that the TouchSecure® Model: Connectivity MUL device mentioned herein is
in compliance with the essential requirements and other relevant portions of the Directive R&TTE
1999/5/EC.
IDT.QM.P2.T1.DT
Printed copies of this document are uncontrolled
Ver1.0
Page 11 of 11
Internal Use Only

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Sixtus
Create Date                     : 2013:07:19 14:47:27-07:00
Modify Date                     : 2013:07:19 14:47:38-07:00
Subject                         : 
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2013:07:19 14:47:38-07:00
Creator Tool                    : Acrobat PDFMaker 10.1 for Word
Document ID                     : uuid:c8b8ba51-8569-4279-abca-c65782673d42
Instance ID                     : uuid:a1fb8dc6-8b20-4f27-93b9-945539c7dae9
Format                          : application/pdf
Title                           : Document Template
Description                     : 
Creator                         : Sixtus
Producer                        : Adobe PDF Library 10.0
Keywords                        : 
Source Modified                 : D:20130719214638
Company                         : SCM India
Page Layout                     : OneColumn
Page Count                      : 11
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MBPTSCTYMU-02

Navigation menu