Infopia IGM-1001D Lipid profile and glucose measuring system for self testing User Manual 1
Infopia Co.,Ltd. Lipid profile and glucose measuring system for self testing 1
Infopia >
User Manual
Operation Manual Dear IGM-1001D Blood Glucose Monitoring System Owner, Thank you for choosing the IGM-1001D Blood Glucose Monitoring System. This manual contains everything you need to know about your new glucometer and how it works. Please take a moment to read the instructions carefully. We understand that self-testing of blood glucose level provides a way to control your diabetes and may give you peace of mind by testing regularly. As a result, IGM-1001D has been developed to provide you with a fast and accurate reading in a convenient and simple process. Our goal for the IGM-1001D Blood Glucose Monitoring System is to provide you with the best quality healthcare products coupled with superior customer service. Always consult with your healthcare professional, before making any changes to your diabetes management. The IGM-1001D Blood Glucose Monitoring System is for in-vitro diagnostic use only. Customer Service is available 24 hours a day, 7 days a week, and 365 days a year. Please call customer support center in your local area. Important Information The IGM-1001D Blood Glucose Monitoring System is intended for use outside the body (in-vitro diagnostic use only). It should be used only for testing blood glucose and only with fresh capillary whole blood samples. It should not be used for the diagnosis of diabetes. Consult with your physician or diabetic healthcare professional about daily management of your diabetes and proper use of the glucometer. Please pay close attention when handling blood. Improper procedures may cause serious hazards to your health. The IGM-1001D Blood Glucose Monitoring System contains small parts, which could be a choking hazard for children if swallowed. WARNING: 1. All parts of the kit are considered bio-hazardous and can potentially transmit infectious diseases, even after you have taken cleaning and disinfection measures. 2. Always use a new, sterile lancet. Lancets are for single use only. 3. Avoid getting hands lotions, oil, dirt or debris in and/or on the lancets and reusable lancing device. 4. Please refer to page 12 for cleaning and disinfecting IGM1001D Blood Glucose Monitoring System. 5. Do not change your medication based on the IGM-1001D meter test results without contacting your physician or healthcare professional first. 6. Do not assemble or disassemble the blood glucose test meter 7. Keep out of direct sunlight. CAUTION: Following list of IMPORTANT SAFETY INSTRUCTIONS provided: 1. Close supervision is necessary when equipment is used by, on, or near children, handicapped persons or invalids. 2. Do not place the equipment in liquid, nor put it where it could fall into liquid. If the equipment becomes wet, remove the batteries and dry the device. 3. Use the equipment only for the purpose described in the instructions for use. 4. Do not use accessories which are not supplied or recommended by the manufacturer. 5. Do not place anything on top of the equipment. Test Principle IGM-1001D blood glucose test strip is the bio-sensor which has been made by the FAD-dependent glucose dehydrogenase(enzyme). FAD-GDH(enzyme) quantitatively reacts with the glucose in the whole blood and the mediator. 34At this moment, mediator Fe(CN)6 is reduced to Fe(CN)6 . 4This Fe(CN)6 generated by the reaction is re-oxidized on carbon electrode, for which the method is called amperometry. The measured oxidation current exists in proportion to the glucose concentration in the whole blood. INFOPIA CO., LTD Page 1 UM-M (Rev.0) Learning the System Table of Contents Intended use of Blood Glucose Test Meter The IGM-1001D Blood Glucose Monitoring System is intended for use outside the body only (in-vitro diagnostic use) and self-testing. Recorded results make it easier for your doctor to access your metabolic control. However, the self-testing should not take the place of overall diabetes management assessment from your doctor. It should be used for testing blood glucose (sugar) only with fresh capillary whole blood samples. IGM-1001D Blood Glucose Monitoring System is intended for use in places like home and in professional setting to monitor blood glucose levels. Learning the System Intended use of blood glucose test meter IGM-1001D kit components IGM-1001D meter IGM-1001D meter Display IGM-1001D test strip --- 2 --- 3 --- 3 --- 3 --- 4 Before Testing: Setting your meter Auto-coding function Performing a control solution test --- 4 --- 5 --- 5 CAUTION - Do not use system for any other purpose than blood glucose test. - Cholesterol concentrations > 500 mg/dL or triglyceride concentrations > 3,000 mg/dL may produce elevated reading. - Icodextrin does not interfere with this version of IGM-1001D test strips. - Do not use during or soon after xylose absorption testing. Xylose in the blood will cause interference. - Before using any product, please read all instructions. - Consult with your physician or diabetic healthcare professional about daily management of your diabetes and proper use of the glucometer. If you have any questions about the IGM-1001D product, please contact your local representative. Performing Your Test: Testing Blood - preparation Performing a blood test with your finger tip Test strip ejector function --- 6 --- 7 --- 9 Reviewing Your Results: Reviewing your blood sugar Reviewing your averages ---9 --10 Alternate Site Test: Lancing and sampling from an alternate site area Lancing device clear cap is used for alternate site testing --10 --11 WARNING - Before using IGM-1001D system, read all instructions in this manual, and practice for accurate and safe test. You should have commentary recommendation from your diabetes care professional for the proper use of the meter and daily management of your diabetes. - If you think your blood glucose results are too low or too high, or if the results are doubtful, please contact your doctor. - If your blood glucose result is unusually low or high, or you do not feel the result is correct, repeat the test again with a new test strip. - If the results are still inconsistent, please consult with your physician before making any decision in controlling your diabetes. Caring for Your IGM-1001D System: Cleaning your meter and maintenance Storage of your IGM-1001D system Transferring Your Result Data Download Application Battery Installation Dispose of meter and batteries Trouble-shooting Warranty Specifications Symbol Reference INFOPIA CO., LTD --12 --12 --12 --13 --13 --13 --14 --15 --15 --15 Page 2 UM-M (Rev.0) IGM-1001D Kit Components 1. IGM-1001D Meter 2. IGM-1001D Test Strip 3. Reusable Lancing Device 4. Lancets 5. Operation Manual 6. Warranty Registration Card 7. Carrying Case 8. Patient Logbook 9. 2EA of 3V Coin Battery (CR2032) Your IGM-1001D Blood Glucose Monitoring System has been sealed to protect the contents. If you find your seal has been broken, please return it to the place of purchase. CAUTION 1. Do not use IGM-1001D glucose test meter in a dry environment, especially if synthetic materials are present. Synthetic clothes, carpets, etc., may cause damaging static discharge in a dry environment. 2. Do not use IGM-1001D glucose test meter near cellular or cordless telephones, walkie-talkies, garage door openers, radio transmitters, or other electrical equipment that are sources of electromagnetic radiation, as these may interfere with the proper operation of the glucose test meter. IGM-1001D meter display Low Battery Warning Symbol IGM-1001D meter Alarm Symbol Test Strip Port: Insert the IGM-1001D test strip Troubleshooting Symbol Delete Results Display Screen: Displays your test results, symbols and messages. Average Test Result System Before Having a Meal After Having a Meal Power/Enter Button: Power the meter on/off, prompts memory data and acts as an “Enter” button during setup and after tests. After Taking Medication After Sport Activity Control Solution Symbol Blood Drop Symbol for Test Strip Code Symbol Up/Down Arrow Buttons: Scroll up or down to adjust settings or retrieve memory. Test Result Unit SymbolTemperature / Date Time / Test Result Amount IGM-1001D test strip Test Strip Ejector: Releases and discards test strip Serial Number: Battery Cover: INFOPIA CO., LTD Page 3 Number Name Function Entrance Blood goes into this area. Air exit As blood enters, air exits thru this area Confirmation Able to see through this window whether Window blood is fully filled. Connector Connect between the electrodes and meter Auto-coding label Automatic coding recognition UM-M (Rev.0) Setting Your Meter CAUTION 1. Store the IGM-1001D test strip vials in a cool, dry place. Keep out of direct sunlight. Do not freeze. 2. Store test strips in their original vial only. Do not mix the test strips in new vials or in any other container. 3. Immediately replace the vial cap and close tightly after removing any test strips from the vial. 4. Make a note of the expiry date, which is three months from the date you first open a new vial of strips. Throw IGM-1001D test strips and vial away after the expiry date. 5. Do not use the test strips after the expiration date printed on the package or vial, since it may cause inaccurate results. 6. IGM-1001D test strips should be single use only. DO NOT RE-USE. 7. Do not test at temperatures below 10℃(33.8°F) or above 40℃(104°F). 8. Do not test in the condition that humidity is below 10% or above 90%. 9. Do not bend, cut, or alter the test strip. 10. Avoid getting dirt, food, and water on the test strip with wet hands. 11. Avoid getting dirt, food, and water on the color-coding label (backside of test strip) 12. Refer to additional information in the IGM-1001D test strip package. The IGM-1001D meter has a wide variety of functions to choose from. From the setup mode you have the ability to turn activity/meal flags, set the date/time, designate three unique averages and set up to five daily alarms. Power On Press for 3 seconds at least User Activity Option After pressing and releasing either ▲ or ▼ buttons to turn the User Activity Option on/off, confirm with Year After pressing and releasing either▲ or ▼ buttons to set the year, confirm with Date / Time After pressing and releasing either▲ or ▼ buttons to set the date and time, confirm each with Number of days for average After pressing and releasing either▲ or ▼ buttons to set the number of days for average calculation (3 different possible), confirm with Alarm on/off After pressing and releasing either▲ or ▼ buttons to turn the alarm on/off, confirm with Alarm time After pressing and releasing either ▲ or ▼ buttons to set the alarm hour and minute, confirm with Alarm After programming the number of desired alarms (5 alarms possible), confirm with Before Testing WARNING To reduce the chance of infection: 1. Lancing device and lancets should NOT be shared with others. 2. Always use a new lancet and a new blood glucose test strip. 3. Practice using the lancing device and become accustomed with its use. 4. Lancets and blood glucose test strips should be single use only. 5. Wash your hands in warm clean running water using soap before testing. 6. Avoid getting hand lotion, oils, dirt or debris on the lancets or on the lancing device. 7. Dry your hands completely before testing. INFOPIA CO., LTD Page 4 CAUTION 1. VERY IMPORTANT: Set the right test unit. Your IGM-1001D Meter is pre-set to mg/dL as test unit. A wrong test unit will read to wrong test result display. Please consult your healthcare professional if you’re not sure which test unit to use. Without setting the date properly, the average glucose level and the results in memory will not show proper values. It is recommended to set the glucose test meter before use and also when new batteries are installed. 2. You cannot test your blood glucose in the setting mode. 3. To turn the meter off during the setup, press for at least 3 seconds. UM-M (Rev.0) Auto-coding Function Performing a Control Solution Test 1. IGM-1001D has automatic code recognition function(e.g. C26) IGM-1001D control solutions contain a known amount of glucose that reacts with IGM-1001D test strip. By comparing your control solution test results with the expected range printed on the test strip vial, it is able to check the meter and test strips are working properly and that you are performing the test correctly. It is very important that you perform the check routinely to make sure you get accurate results. 2. It recognizes the code number automatically. This is a very convenient function preventing the inconvenience of setting the code number on the glucose test meter every time. Check the code on the vial to see if the codes match each other The Glucose control solution should be used Before using a new box of strips Whenever you suspect the blood glucose test meter or blood glucose test strip is not functioning properly. If your blood glucose test results are not consistent with your symptoms or if you think they are not accurate. If you have dropped the blood glucose test meter. For quality control in the point of care usage. For teaching or learning the system. When using the meter for blood glucose tests after any disinfection procedure. CAUTION 1. Do not bend the glucose test strip to prevent the automatic code recognition failure. 2. If the code recognition label is damaged, code recognition may fail. Please check the code number on the LCD window together with the code number on the glucose test strip vial to see if code numbers match each other. Firmly insert the test strip into the meter test port. Insert down firmly in direction of arrow on test strip (arrow up). Please do not insert the glucose test strip upside down. When you insert the glucose test strip into the glucose test meter, the power automatically adjusts the meter accordingly. IGM-1001D 26 Backlight Function When inserting IGM-1001D glucose test strip (starting measuring process), backlight will turn on for 10 seconds. Before inserting blood, Scroll through the icons with the ▲ or ▼ button until the control solution bottle is blinking, press After the test result displays, backlight will last for 10 seconds. By pressing the power button (moving into memory mode), backlight will turn on for 10 seconds. 1. Check the expiration date before performing a control solution test. Do not use if expired. Please note the expiration date on the control solution bottle. When pressing the power button for 3 seconds (entering the setting mode), backlight will turn on for 10 seconds. 2. Gently shake the control solution before use. When inserting the PC cable into the USB port, backlight will turn on for 10 seconds. 3. Discard the 1st drop of control solution, this will eliminate any residue. Place a drop of control solution on a clean dry surface (e.g. the lid of the test strip vial) INFOPIA CO., LTD Page 5 UM-M (Rev.0) Please call customer support toll: 82-31-460-0300 4. Dip the test strip into the control solution. Results will appear in 5 seconds. Compare the result to the range printed on the test strip vial, the result should fall within that range CAUTION 1. Control solutions is for in-vitro diagnostic use only. This means that it is only used for testing outside the body. 2. Control solution is exclusively made for the IGM-1001D Blood Glucose Monitoring System. Do not use other brand control solutions made by other manufacturers. 3. Check the expiration date on the vial. Do not use, if expired. 4. Once opened, use it for the next three months only. Record the discard date on the control solution bottle. Discard after three months. 5. Do not swallow. This is NOT for human or animal consumption. 6. The control solution bottle icon contains letter ‘C,’ so as not to be confused with the medication bottle. This will allow you to understand differences between a control solution test and an actual blood test. For example only : If you are using the normal control solution, according to this particular vial of strips, your meter should show a number between 80 and 120. IGM-1001D IGM-1001D H. 255-345 N. 80-120 L. 35-65 IGM-1006 IGM-1001D IGM-1001D Follow-up Action 1. Check your meter and strip with the glucose control solution. 2. Perform your test again. CAUTION 1. If your glucose control solution falls out of range, do not perform a glucose test and please contact your local distributor. 2. The glucose control solution’s measurement range has nothing to do with individual’s blood glucose level, as its own purpose is to check the status of strip and meter. Discard the used control solution and test strips carefully, according to the local regulation. Performing Your Test Testing Blood - Preparation Lancing device is a convenient medical tool for collecting capillary blood samples for glucose monitoring or other tests which require one or two drops of blood. Being a more advanced lancing device, it provides ultimate safety and comfort for obtaining blood samples. An adjustable tip offers 5 different strength levels of skin penetration for individual user’s comfort, while a lancet ejector enables the safe disposal of the used lancet. As an added bonus, this also comes with a transparent tip for AST (Alternative Site Testing). CAUTION 1. Please note that the control values shown in the picture are not control ranges. 2. NOTE: - It is recommended that glucose control solution is stored at room temperature 20~25℃ (68~77℉) before testing. - Check the expiration date before performing a glucose control solution test. - Do not use if it expired. Once opened, the control solution expires after 3 months. 3. 4. If your control solution test falls out of range, please follow the next steps before contacting customer support: Check the expiration dates on all the products you are using. Be sure you are using IGM-1001D control solution. Try another control solution test. If this test falls out of range, try another control solution test with a new unopened bottle of strips. After following the appropriate steps and the control test still falls out of range, do not perform a glucose test. 7. INFOPIA CO., LTD Page 6 5. 6. Never use a lancet that has been used by someone else. This could lead to contamination. If the lancing device is to be used by another person, the unit must use a new tip or properly disinfected Do not leave the lancet in the device after use. A new lancet must only be placed into the lancing device directly before testing. This device has many small parts and could be a choking hazard for children if swallowed. In the case of hospital use, hospitals need to observe their own infection control protocols in order to avoid any contamination. Always dispose of the used lancet in a biohazard garbage container. UM-M (Rev.0) Performing a blood test with your fingertip Components Step 1 1. Firmly insert the test strip into the meter test port. Insert down firmly in direction of arrow on test strip (arrow up). Please do not insert the glucose test strip upside down. When you insert the glucose test strip into the glucose test meter, the power automatically turns on with the code and temperature. Using the Clear Tip(AST) 1. Place the lancing device and lancet on the skin in the chosen area, press and hold it continuously for a few seconds, then push the release button to take a blood sample. 2. Watch through the clear tip until a sufficient blood sample is taken. If there is not enough blood, gently massage the area until a sufficient sample is collected. STORAGE Products must be stored at room temperature protected from sunlight or moisture. CLEANING AND DISINFECTION -Clean and wipe the outer part of lancing device once a week at the minimum with a soft cloth dampened with mild soap and water. Wash the adjustable tip and clear tip, once a week with mild soap. -DO NOT immerse the lancing device in water or liquid. WARRANTY Lancing device has a 2-year warranty from the date of purchase. A malfunctioning device should be returned to the following address: Manufacturer : GMMC Room No. 1112, Ace Tower 9th Bldg., 345-30, Gasandong, Geumcheon-gu, Seoul, South Korea Tel : +82 2 2104 0470 Fax : +82 2 2104 0472 EU Authorized Representative : GMMC, S.L. C/Vinalopo' 4 - 1° - Pta 4 Valencia, Spain Tel : +34 963 691 484 Fax: +34 961 125 949 INFOPIA CO., LTD 2. Make sure the code number matches on the strip bottle its code (e.g. C26). The IGM-1001D automatically recognizes the test strip code number and adjusts the meter accordingly. A blinking test strip will appear at the top of the screen indication the meter is ready for testing CAUTION 1. If the code is not displayed after for a while, pull the glucose test strip out of the port, and re-start the procedure from the beginning. 2. If the code on the LCD display window as well as on the glucose test strip vial does not match, try another new glucose test strip. If the mismatch persists, please contact your local representative for assistance. 3. Avoid testing under direct sunlight, for a more accurate test result. 4. If you apply your blood sample too early, Er5 message will appear on LCD. Please refer to Page 12. Step 2 To obtain a suitable blood samples Before obtains a blood sample, wash your hands with warm, clean water and soap. Dry hands completely before testing. WARNING 1. All parts of the kit are considered bio hazardous and can potentially transmit infectious disease, even after you have conducted cleaning and disinfection measures. 2. To reduce the chances of getting infection: The test strips are for single use only. Do not reuse. 3. Avoid getting hands lotion, oil, dirt or debris in or on the lancets (single use only) and the lancing device. 4. Wash your hands thoroughly with soap and clean water after handling the meter, lancing device and/or test strip. Page 7 UM-M (Rev.0) Step 3 1. Unscrew the lancing device cap. 2. Insert a sterile lancet into the lancing device. 3. Twist the protective cover off. Do not discard. IGM-1001D test meter only requires 0.5 ul sample volume. Place the edge of the test strip to the drop of blood. The blood will automatically be ‘drawn’ into the test strip channel. When your sample blood is enough, your meter will automatically count down 4. Put the lancing cap back and twist it tightly. 5. To adjust the depth setting: Use strength level 1-2 for soft skin, 3 for average skin, 4-5 for thick or calloused skin. 6. Pull the end of the lancet device back. CAUTION 1. If the countdown does not start, do not add more blood to the glucose test strip. Discard the glucose test strip and re-start testing. 2. If you do not conduct the test within 3 minutes, the glucose test meter will automatically power off to save battery life. In this case, test procedure should start again from the beginning. 3. You may get an inaccurate result if the blood sample is not completely filled. 4. You must inject the blood sample until beep sounds. Step 4 7. To prick your finger, push the center button. CAUTION 1. If the blood smears or runs, do not use such blood sample. Dry the area and gently squeeze another drop or puncture a new area of the finger. Do not share reusable lancing device with anyone After the beeping sound, the test will begin automatically and your results will appear in 5 seconds. It should begin counting down from 5 to 1 second on the LCD display window. The LCD window will display the result of your blood glucose level. Temperature and time. After results displayed, you choose to use the activity/meal flags ( ), press and release ▲ or ▼ button to select the activity, then press and release the power button INFOPIA CO., LTD Page 8 UM-M (Rev.0) Record the result value in your logbook. When glucose test strip is removed, the glucose test meter turns off automatically. CAUTION 1. If the test result is out of the test range, “Hi/Lo” message will be shown on the LCD window. 2. Safely discard used glucose test strips and lancets in the proper place, according to the local regulation. CAUTION 1. If you push the ejector button forward too much, it may be part of the failure. 2. Do not give strong impact to blood glucose test meter. 3. Please follow the waste disposal regulations on the used lancets and strips imposed by your local authorities. Reviewing Your Results The IGM-1001D meter stores up to 365 test results in its built-in memory, along with the average sugar level for the number of days, which you had preset the glucose test meter to calculate. Test Strip Ejector Function Reviewing Your blood sugar Disposing of your test strip Once the test is complete, push the strip forward to remove the test strip from the meter Press and release button. The most recent result appears first. Note the time and day of your blood sugar result. Press and release the ▼ button and your previous result will appear on the display Reviewing Your averages Used test strips may be considered bio hazardous waste in your area. Be sure to contact your local representative for proper disposal Press and release the ▲ button and your average result will appear on the display. Average Test Result Disposing of your lancet Test Unit Test Result Amount Average Test Result Days Push the needle into the protective cover. Deleting Test Results Pull the lancet out and discard accordingly. INFOPIA CO., LTD Page 9 Deleting individual test result To delete any individual test result in the memory press ▲ or ▼ button for 3 seconds, while the test result is to delete, displayed blinking. After the third beep sound you may hear, the test result is deleted. UM-M (Rev.0) Deleting all test results To delete all test results in the memory press ▲ and ▼ button for 3 seconds, while the test result is to delete, displayed blinking. After the third beep sound you may hear, the test results are deleted. alternate site is less painful than using a fingertip. Getting a blood sample from your forearm or palm is different than getting a sample from your fingertip. Ventral palm/Dorsal hand Choose a fleshy area on the palm, below your thumb or pinky finger. Select a spot without any visible veins and away from any deep lines. This may cause your blood sample to smear. CAUTION The deleted test results cannot be recovered. Please be careful in deleting the test results. Alternate Site Test The IGM-1001D Blood Glucose Monitoring System gives you the ability to obtain a blood sample for testing your sugar from different areas of your body. The figure shown above displays the areas where you can test using your IGM-1001D meter. You may test you blood sugar from your forearm, upper arm, palm (ventral palm or dorsal hand), fingertips, thigh, or calf. IMPORTANT It is recommended that alternate site testing be used when sugars are stable: before meals and before bedtime. However, when sugars are changing, blood from the fingertip may show these changes sooner than blood from other sites. LIMITATION 1. Alternative site testing results should never be used to calibrate continuous glucose monitoring systems. 2. Alternative sampling results should never be used in insulin dosing calculations. Forearm Upper arm Calf Thigh Choose a fleshy area of the forearm, upper arm, thigh, or calf away from bone, visible veins and/or hair. Sometimes there is less blood flow to these areas than to the fingertip. To help you get a large enough drop of blood, you may gently message or apply a heating pad to the site to increase blood flow. IMPORTANT We recommend that you test on your fingertips if you are testing for hypoglycemia (low blood glucose) or if you are suffering from hypoglycemia unawareness To ensure accurate results when lancing your arm (forearm or upper arm), leg (calf or thigh), or palm (ventral palm or dorsal hand), clean the test site with soap and water. Make sure there is no cream or lotion on the test site. Thoroughly dry your hands and test site. WARNING To reduce the chances of getting infection: never share a lancet or reusable lancing device with anyone. Lancing and sampling form an alternate site area Sampling from your upper arm, forearm, dorsal hand, ventral palm, thigh, or calf allows you to use your fingertips less often. You may find that obtaining a blood sample from an INFOPIA CO., LTD Page 10 UM-M (Rev.0) The lancing device clear cap is used for alternate site testing Lance the test site with the lancing device 1. Remove the lancing cap by twisting off. 2. Insert lancet and replace with the clear cap. 3. To bring fresh blood to the surface of the test site, rub the test site vigorously for a few seconds until you feel it getting warm. Applying heat may be helpful. REMEMBER 1. Consult with your healthcare professional before using alternate site testing. 2. Choose a different puncture site each time you test. Repeated punctures in the same spot may cause soreness and calluses. 3. If bruising occurs at an alternate site or you have difficulty getting a sample, consider sampling from a fingertip instead. You may want to review the choice of sites with your healthcare professional. 4. Do not share reusable lancing device with anyone including other family members. CAUTION Do not test on you forearm or palm when 1. You think you blood glucose is rapidly falling. For example within two hours of exercise, rapid-action insulin injection, or an insulin pump bolus. 2. Testing with a fingertip sample may identify hypoglycemia or an insulin reaction sooner than testing with a forearm or palm sample. 4. Adjust clear cap to the highest setting. Hold the clear cap down against a fleshy area on the alternative site. Press the release button. Do not lift up. 5. Continue to hold the lancing device and gradually increase pressure for several seconds. 6. While holding the lancing device on your test site, look through the clear cap; until a round drop of blood appears 7. Lift the lancing device straight up; be careful not to smear the blood on your testing site. 8. Place the edge of the test strip to the drop of blood. The blood will automatically be drawn up. INFOPIA CO., LTD Page 11 UM-M (Rev.0) Caring for your IGM-1001D System Cleaning your meter and maintenance Blood glucose test meter : Your blood glucose test meter does not require special maintenance or cleaning. Avoid getting dirt, dust, blood, glucose control solution, or liquids on the blood glucose test meter, the test port, or data port. Your blood glucose test meter’s operation temperature is 10~40°C(50~104°F). It is recommended that you store the blood glucose test meter in the portable pouch after each use. A cloth dampened with water and mild detergent can be used to wipe down the outer part of the blood glucose test meter. Your IGM-1001D blood glucose test meter is a precision instrument. Please handle it with care. Lancing device : Clean the lancing device and caps with soap and tepid water. To disinfect the lancing device, prepare a disinfectant solution household bleach and water in 1(bleach) : 9(water) ratio. Dampen a cloth with this solution and wipe the lancing device thoroughly. Soak only the cap for at least 30 minutes in the disinfectant solution. Do not soak the lancing device in liquid. Rinse the lancing device and cap with water, and dry thoroughly. 1. For detailed instructions concerning IGM-1001D blood glucose test strips, refer to the blood glucose test strip package inserted and found in the blood glucose test strip box. 2. Please store the IGM-1001D blood glucose measuring system in a cool and dry area, out of reach of children. Do not freeze. For a more accurate test result, avoid testing under direct sunlight. 3. Do not soak the blood glucose test meter or blood glucose test strips in water or liquid. 4. Do not subject the meter or blood glucose test strips to excessive heat. 5. Use your meter according to the instructions in the manual. 6. If you need to purchase the lancing device, lancets or blood glucose test strips, contact your local representative. 7. Discard the used lancets carefully, to prevent any infection. away from direct sunlight and heat. Do not freeze. After removing a test strip from the vial, immediately close it tightly. Record the discarded date (date vial opened, plus 3 months) on the strip label. Do not use if it is expired(2 years) after manufacturing. Touch the test strip with clean and dry hands. Do not use if 3 months have been passed, since the opening of the vial cap for strips. Control Solution Storage Storage condition: Store in a cool, dry place at between 8~30 ℃ or 46~86 ℉ (Temperature) After use, close cap tightly. Make sure the control solution bottle is tightly closed Record the discarded date (date vial opened, plus 3 months) on the control solution on the bottle. Do not use if expiry date has passed. It expires 24 months after manufacturing date. It expires 3 months after opening the vial cap. CAUTION 1. Store the IGM-1001D test strip vials in a cool, dry place. Keep out of direct sunlight. Do not freeze. 2. Store test strips in their original vial only. Do not mix the test strips in new vials or in any other container. 3. Immediately replace the vial cap and close tightly after removing any test strips from the vial. 4. Make a note of the discard date, which is three months from the date you first open a new vial of strips. Throw IGM-1001D test strips and vial away after the discard date. 5. Do not use the test strips after the expiration date printed on the package or vial, since it may cause inaccurate results. 6. Do not test at temperatures below 10℃(50°F) or above 40℃ (104°F). 7. Do not test with humidity below 10% or above 90%. 8. Do not bend, cut, or alter the test strip. 9. Avoid getting dirt, food, and water on the test strip with wet hands. 10. Avoid getting dirt, food, and water on the color-coding label (backside of test strip) Storage of your IGM-1001D System To prevent the meter and test strips from getting dirt, dust or other contaminants, please wash and dry your hands thoroughly before use Meter Storage Storage condition: 10~40 ℃ or 50~104 ℉ (Temperature) / 10 ~ 90% (Humidity) Always store and transport the meter in its original storage case. Avoid dropping and strong impact. Avoid direct sunlight and humidity. Strip Storage Storage condition: 2~30 ℃ or 36~86 ℉ (Temperature) / 10 ~ 90% (Humidity) Store your test strips in their original vial only. Do not store the strips in other containers. Store test strip packages in a cool and dry place. Keep INFOPIA CO., LTD Page 12 UM-M (Rev.0) Transferring your results lithium batteries (CR2032), which are included. When replacing the batteries, only CR2032 or equivalent lithium battery should be used. USE to Data Transfer CABLE(Option) You can transfer test results from the IGM-1001D meter to a computer. You will need to download to software from the following web site (http://www.infopia21.com) and purchase the computer cable from your local representative. This is sold separately. Follow-up Action 1. Check your meter with the glucose control solution 2. Perform your test again. 3. If you are experiencing symptoms that are not consistent with your blood glucose test results, call you healthcare professional. NOTE: 1. Make sure your date and time are correct after changing your battery. 2. Remove both batteries from the battery compartment and dispose of them, according to your institution's guidelines.. CAUTION 1. Risk of explosion if battery is replaced by an incorrect type. 2. Dispose of used batteries according to the instructions. USE to Bluetooth Unit 1. Press the ‘Up’ button of the IGM-1001 meter, running pairing mode. LCD Screen displayed ‘P’ and start count from 0. 2. run to application on mobile phone. 3. Operating search mode on mobile phone. 4. select the operating meter in search list. 5. if pairing is succeeded, meter LCD screen displayed ‘P’ -> ‘C’ and re-start count from 0. 6. ‘Data Update’ command from the mobile phone to meter. 7. Glucose data sent from meter to mobile phone. LCD screen displayed re-start count to 0. 8. connection termination : Press ‘Power’ button or application exit on mobile phone. 8. if connection is fail, LCD screen displayed ‘C’ -> ‘P’. After some seconds meter is power off automatically. 9. if pairing is incompleted, re-start to list 1. Download application Dispose of meter : The meter must be disposed of according to the local regulations concerning the disposal of electrical and electronic equipment. The Waste Electrical and Electronic Equipment(WEEE) regulation implement provisions of the European Parliament and Council Directive 2012/19/EU aimed to reducing the amount of EEE waste going for final disposal. The manufacturer,has specific instructions for the recovery of the meter. Please contact your distributor. Dispose of batteries : Please recycle or dispose of used batteries using your local battery collection systems and in compliance with your local environmental laws and regulations. Batteries contain chemicals that, if released, may affect the environment and human health. The crossed-out wheeled-bin symbol indicates the need for the separate collection for batteries. Use apple app store or google play. Battery Installation The low battery icon will appear in the upper left corner of the LCD display to alert you when the battery power is running low, indication a new battery are needed. Your IGM-1001D blood glucose test meter uses only two 3V INFOPIA CO., LTD Page 13 UM-M (Rev.0) Troubleshooting Message What it means The following chart may help you identify certain problems, but may not solve all problems that can occur. Contact your authorized representative or Infopia Co.,Ltd. customer support if the problem persists. Message What it means Action required Problem with the blood glucose test meter Place the battery again, and set the blood glucose test meter. If the problem persists, Please contact your authorized representative or customer support. Caused by either used or wet blood glucose test strip Please, insert a new glucose test strip and perform your test again Problem with the test strip Please insert a new glucose test strip and apply the blood sample until confirming the window is completely filled. Blood glucose test strip is damaged User applied the blood sample before the LCD display was blinking Color bar of the strip is dirty or not good or there is too much light. Action required. The ambient temperature is less than 10℃ (50℉) The ambient temperature is over 40℃ (104℉) The test result is lower than 10mg/dl INFOPIA CO., LTD The test result is higher than 700mg/dl Action required performing a glucose control solution test. If the test results in a normal reading, retest your blood sample two or three times. If "Lo" persists, consult your doctor immediately. Check the accuracy of your blood glucose test strip by performing a glucose control solution test. If the test results in a normal reading, retest your blood sample two or three times. If "Hi" persists, consult your doctor immediately. There are no reading stored in the meter Not enough reading in the memory to display designated average Please insert a new glucose test strip and perform your test again Wait for the meter to display the blinking icon before applying your blood sample. Please insert a new glucose test strip and perform your test again. If blink with “Sun”, avoid to the direct sunlight and retest. Contact your local representative or customer support if the problem persists. Place the meter at a temperature between 10 ~ 40℃ (50 ~ 104 ℉) for more than 10 minutes or more and test again. The glucose test meter does not power its ON Battery is dead or there is a problem with the meter Change the battery and if the problem persists, contact your local representative. The glucose test meter does not start after applied blood sample. Insufficient amount of blood. Please insert a new test strip and perform your test again. The results are inconsistent There may be a problem with the glucose test strip Please insert a new test strip and perform your test again. Place the meter at a temperature between 10 ~ 40℃ (50 ~ 104 ℉) for more than 10 minutes or more and test again. Check the accuracy of your blood glucose test strip by Page 14 UM-M (Rev.0) Inconsistent or Unexpected Test Results Declaration of Conformity If you continue to get unexpected results, check your system with control solution. If you experience symptoms that are not consistent with your glucose results, review and follow all instruction in this manual. Never ignore symptoms or make significant changes to you diabetes control program. Inform health care professional of symptoms and/or concerns. FCC CAUTION 1. Low Glucose Results: if your result is lower than 70mg/dL, it may mean hypoglycemia (low blood sugar). This may require immediate treatment according to your healthcare profession’s recommendations. Although this result could be due to a test error, it is safer to treat first and you may test another. 2. High Glucose Results: if your test result is higher than 180 mg/dL, it may mean hyperglycemia (high blood sugar). If you are uncertain about your test results, consider with re-test. Your health care profession will help you to decide how it action. If the meter displays HI all the time, please re-check your blood sugar but still it’s higher, please find your healthcare profession immediately. Warranty Manufacturer’s Warranty Infopia Co.,Ltd. warrants to the original purchaser that this instrument will be free from defects in workmanship for 3 years from the date of original purchase. Limitations of Warranty This warranty is subject to the following exceptions and limitations. 1. Infopia Co.,Ltd. shall not be required to replace any units which are damaged or malfunction due to abuse, accidents, alteration, neglect, misuse, maintenance by someone other than Infopia Co.,Ltd. or failure to operate in accordance with the instructions. 2. Infopia Co.,Ltd. reserves the right to make changes in design without obligation to incorporate such changes into previously manufactured instruments. 3. Infopia Co.,Ltd. has no knowledge of the performance of the instrument when the test strip is altered or modified in any manner. THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. Operation is subject to the following two conditions; (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. For Warranty Service Purchaser must contact the customer service department of Infopia Co.,Ltd. by calling toll 82-31-460-0300, for assistance and/or instructions for obtaining service of this instrument. Service Information Infopia Co.,Ltd. has trained specialists to help you 24 hours a day, 7 days a week, and 365 days a year. IMPORTANT Confirming to Infopia Co.,Ltd. representative before returning your meter for any reason. You will be given the information needed to get your problem handled correctly and efficiently. Remaining your meter, test strip and control solution nearby when you call. INFOPIA CO., LTD Page 15 UM-M (Rev.0) Specifications Separate collection of batteries Sample Type Sample Volume Test Range Reading Time Hematocrit Altitude Operating Temperature Operating Humidity Strip Storage Temperature Display Type Dimension(HxDxT) Weight Power Source Batter Life Capillary, venous, arterial whole blood 0.5 ㎕ 10 ~ 600 mg/dL 5 seconds 20 ~ 60% 3048 meter Up to (10,000 feet) 10 ~ 40℃ (50 ~ 104℉) 10 ~ 90% Store 2~30 ℃ or 36~86 ℉ and no direct sunlight. Do not Freeze LCD (Including backlight model) 96 X 56 X 23.5 (mm) 66±1g (Including batteries) 3V (Coin Battery, CR2032 X 2EA) IGM-1001D: Running 1,000 Tests Infopia Co., Ltd. 132, Anyangcheondong-ro, Dongan-gu, Anyang-si, Gyeonggi-do, Korea www.infopia21.com Obelis S.A Bd. Genaral Wahis 53, 1030 Brussels, BELGIUM Tel : +(32)2.732.59.54 Fax : +(32)2.732.60.03 E-Mail : mail@obelis.net Rev. 2012-03 Symbol Reference Symbol MEMO Description Consult Instructions for use Use By date This product fulfills the requirements of Directive 98/79/EC on in-vitro diagnostic medical devices Attention, See Instructions for use For in-vitro diagnostic use Batch code Do not reuse Serial number Date of Manufacture Manufacturer Keep away from sunlight Waste electrical and electronic equipment symbol Temperature limitation Catalogue number Self-testing used Authorized representative in the European Community Biohazard INFOPIA CO., LTD Page 16 UM-M (Rev.0)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 16 Language : ko-KR Tagged PDF : Yes Title : 1 Author : 남증희 Creator : Microsoft® Word 2010 Create Date : 2014:09:29 17:16:50+09:00 Modify Date : 2014:09:29 17:16:50+09:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools