Contents
- 1. Manual
- 2. Manual.pdf
Manual.pdf
Intégration Guide Contactless payment iUC150 & iUC180 Ingenico – 28-32 Boulevard de Grenelle - 75015 PARIS Tél. 33(0)1 58 01 80 00 - Fax 33 (0)1 58 01 91 35 The scope of this document is to assist third party integrators when dealing with Ingenico UNattended products (iUN) such as iUC150 and iUC180, or others. It offers all information needed for a successful integration of iUC150 and iUC180 products into unattended kiosk machines. For any sales information please refer to your Ingenico contact into the region. Updates table Version 0.1 Date 26/04/12 31/05/2012 Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 Nature of modifications First Draft First diffusion 2/70 Author O.Fabregoule E.Dubois A. Soubiranne O.Fabregoule Y. Moreno E.Dubois Visa Copyright © 2012 Ingenico All rights reserved Table of contents GENERAL .............................................................................................................6 1.1 Definition of acronyms .....................................................................................6 1.2 iUC150 & iUC180 payment solution presentation..........................................7 1.2.1 Diagram of iUC180 & iUC150 connectivity and communications..................8 1.2.2 Services ........................................................................................................9 1.3 Description of modules ..................................................................................10 1.3.1 iUC180........................................................................................................10 1.3.1.1 Technical Hardware characteristics ......................................................11 1.3.1.2 iUC180 output connectors description ..................................................12 1.3.1.3 SAM & µSD Installation ........................................................................19 1.3.1.4 Buzzer...................................................................................................20 1.3.1.5 RGB backlight.......................................................................................20 1.3.1.6 Contactless LEDs & Contactless Logo .................................................21 1.3.1.7 Maintenance Button and LED ...............................................................22 1.3.1.8 Keypad..................................................................................................23 1.3.1.9 Cable Protection ...................................................................................24 1.3.1.10 Antenna Installation.............................................................................25 1.3.1.11 Grounding connections .......................................................................26 1.3.1.12 Appearance personalisation................................................................27 1.3.2 iUC150........................................................................................................29 1.3.2.1 Technical Hardware characteristics ......................................................29 1.3.2.2 iUC150 output connectors description ..................................................31 1.3.2.3 SAM Installation....................................................................................33 1.3.2.4 Buzzer...................................................................................................34 1.3.2.5 Contactless LEDs & Contactless Logo .................................................35 1.3.2.6 Cable Protection ...................................................................................36 1.3.2.7 Grounding connections .........................................................................37 1.3.2.8 Appearance personalisation .................................................................38 1.3.2.9 Contactless reader iUC150 and i9500 interconnectivity........................39 1.4 Professional installation Requirement .........................................................40 MAIN ACCESSORIES ........................................................................................40 2.1.1 Generality ...................................................................................................40 2.1.2 Optional USB cable ....................................................................................40 2.1.3 iUC150 Power supply .................................................................................41 2.1.4 Serial cable .................................................................................................41 2.1.5 Adapter cable..............................................................................................42 2.1.6 LLT cable ....................................................................................................42 2.1.7 Stand-by management cable ......................................................................43 IUC180/IUC150 SOFTWARE ..............................................................................44 3.1.1 Software Architecture .................................................................................45 Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 3/70 Copyright © 2012 Ingenico All rights reserved 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 Secure management of software ................................................................46 Operating system........................................................................................47 TELIUM MANAGER on iUC180 only ..........................................................48 Software downloading ................................................................................50 Development station (iUC180)....................................................................53 TERMINAL MANAGEMENT SYSTEM (IUC180) ................................................55 4.1 Introduction.....................................................................................................55 4.2 Basic functions ...............................................................................................55 4.3 Advanced functions .......................................................................................55 4.4 Customers savings with Ingenico TMS solution .........................................55 INSTALLATION PROCEDURE IN KIOSKS .......................................................56 5.1 Kiosk mechanical requirements....................................................................56 5.2 General installation recommendations.........................................................56 5.3 Kiosk suggested layouts for iUC150 iUR250 IUP250...................................57 ASSEMBLY PROCEDURE FOR IUC180 AND IUC150 .....................................57 6.1 Kiosk minimum volume for iUC180...............................................................57 6.2 Kiosk minimum volume for iUC150...............................................................58 6.3 Kiosk preparation for iUC150 or 180 new installation .................................59 6.4 Installing the iUC150/iUC180 in new kiosk ...................................................60 6.5 Connecting the iUC180 or 150 to the kiosk ground.....................................61 Kiosk mechanical requirements ..............................................................................61 MAINTENANCE ..................................................................................................62 7.1 Configuration ..................................................................................................62 7.2 Operating life...................................................................................................62 CLEANING INSTRUCTIONS ..............................................................................62 DISASSEMBLING THE PRODUCTS ACCORDING TO WEEE DIRECTIVE .....63 9.1 iUC180 End-of–life disassembly instructions ..............................................63 9.2 IUC150 End-of–life disassembly instructions ..............................................65 Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 4/70 Copyright © 2012 Ingenico All rights reserved 10 STANDARDS ...................................................................................................67 10.1 iUC 150 Electrical consumptions ...............................................................67 10.2 iUC 180 Electrical consumptions ...............................................................67 10.3 Temperature and humidity..........................................................................67 10.4 Environmental specification continued .....................................................67 10.5 EC standard compliance marking ..............................................................68 10.6 IC statements ...............................................................................................68 10.7 FCC Statement .............................................................................................69 10.8 Environment (WEEE, Batteries and Packaging) .......................................70 Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 5/70 Copyright © 2012 Ingenico All rights reserved 1 GENERAL 1.1 DEFINITION OF ACRONYMS EMC EVA GND GPRS GSM LCD LLT MDB RAM RS232 SMA Electro Magnetic Compatibility European Vending Association Ground General Packet Radio Service Global System for Mobile communications Liquid Crystal Display Local Loading Tool Multi Drop Bus Random Access Memory Recommended Standard 232. A standard for serial binary communications Secure Access Module – the chips storing the electronic cash register in a stored value scheme such as Moneo, Proton or VISA Cash. SubMiniature version A USB Universal Serial Bus SAM Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 6/70 Copyright © 2012 Ingenico All rights reserved 1.2 IUC150 & IUC180 PAYMENT SOLUTION PRESENTATION The iUN series is the new range of Ingenico UNattended (iUN) devices to offer payment into any kiosk through any segments (petrol, transport, vending, parking, etc.). The modules for contactless reading are: • iUC150, • iUC180. These compact devices are designed to fit everywhere, thanks to an easy installation, respectful of EVA standard. Usage can be indoor or outdoor, resisting to harsh environment. Remarks: • For iUC180, additional peripherals can be added to build a complete solution such as printer or bar code reader. Ingenico does not provide these devices so far but they can be connected to the iUC180 (through USB, or RS232). • Ingenico is also offering other iUN modules dedicated to PINPad like iUP250 or Hybrid Card Reader iUR250. • The iUC150 is the preferred contactless peripheral for the iUP250+iUR250 system. The iUN series is the next generation of Ingenico leveraging of experience from previous product ranges, i9500 series or CAD30 series, to renew your experience of unattended payment. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 7/70 Copyright © 2012 Ingenico All rights reserved 1.2.1 Diagram of iUC180 & iUC150 connectivity and communications iUC180 Ethernet 1USB device Power supply 12 – 30 V Max 4 USB host 3A Serial port com0 display MDB slave Main Power supply Contactless cards (Option) GSM / GPRS (Option) Bluetooth (Option) MDB master (Option) Serial port com2 iUC150 Contactless cards Serial port com0 USB device Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 8/70 Copyright © 2012 Ingenico All rights reserved 1.2.2 Services Training Support After-Sales Service Downloading server centre Softwares / Licences Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 − − − − − − − − − − − − − − − − − − − − Installation and exploitation Softwares OEMC/M²OS development ( days) EMV Level 2 package (2 days) Development workstation SDK Hot-line support Technical assistance Fixed cost repair of iUN products User licence Installation and commissioning User training Hot-line support Technical assistance User licence for local loading tool, LLT User licence for applications software User licence for M²OS Licence for software signature tool, SAT Licence for "EMV Level 2 package " Licence for TCP/IP … 9/70 Copyright © 2012 Ingenico All rights reserved 1.3 DESCRIPTION OF MODULES 1.3.1 iUC180 Front view Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 Rear view 10/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.1 Technical Hardware characteristics iUC180 technical characteristics: Mass 680 g 250 x 120 x 64.5 mm (67 with cable protection) (height x width x depth) Dimensions Operating conditions Functional temperature* -20°C, +65°C Max relative humidity 85% at 55°C, non-condensing Maximum backward leaning No constraints Power Supply 12 – 30 V Max Platform Telium2 Memory 16 Mb SDRAM and 128 Mb Flash 3A Contactless cards reading 128 x 64 graphic display RGB Backlight Buzzer RGB LED internal status indicator Functionality 1 Maintenance Button µSD 2 SAMs 1 SIM (optional) 1 Jack for wake-up Wake-up mechanism on RS232 connectors Ethernet GSM/GPRS (optional) Bluetooth (optional) Link 4 USB host (1.2 A total max) 1 USB device 2x RS232 (1 optional) MDB slave MDB Master (optional) Storage conditions Storage temperature -20°C,+65°C Max relative humidity 85% at 55°C, non-condensing Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 11/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.2 iUC180 output connectors description COM 0 MDB Slave MDB Master µSD 2 SAMs SIM COM2 Link Wake-Up Link Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 12/70 Copyright © 2012 Ingenico All rights reserved USB Device USB Hosts Ethernet Bluetooth Antenna GPRS Antenna LLT/Maintenance Button LLT/Maintenance LED 1.3.1.2.1 Ethernet The iUC180 contactless Reader unit can be connected to Ethernet. The connector type is shielded RJ45. The Ethernet cable is standard and not provided. The Ethernet cable must be shielded. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 13/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.2.2 USB device The IUC180 contactless reader unit can be connected by type B USB. 1.3.1.2.3 USB host The iUC180 contactless reader unit can drive 4 USB accessories. The connector is standard type A. The power available is limited to 1.2A Max dispatched between the 4 USB. 1.3.1.2.4 Wake-up mechanism iUC180 is designed to save power thanks to a “stand-by mode”. If the stand-by mode is used, use Wake-up mechanism: - with button connected on jack (optional) - with Pin 2 of COM0 link & COM2 link - by pressing the green key on the maintenance keyboard. Wake-up pin state Hz (high impedance) Stand-by authorized Drive to “0” Wake-up / Stand-by unauthorized The Wake-up pin is drive to “0” by the one asking the wake-up. It could be driven by iUP250, iUR250 or any devices designed to be compliant (Host device…). Contactless Reader IUC180 IUC180 USB COM0 & 2 HZ => Stand-by « 0 » => Wake-up 1 – GND 2 – Wake-up Any devices design to be compliant. HZ => Stand-by « 0 » => Wake-up Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 14/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.2.5 COM0 link The iUC180 contactless reader unit can be connected to serial port COM0. The connector type is RJ11. Pin N° Function GND Wake-up RXD TXD CTS RTS 1.3.1.2.6 COM2 link (optional) The iUC180 contactless reader unit can be connected to serial port COM2 if the option is available. The connector type is RJ11. Pin N° Function GND Wake-up RXD TXD CTS RTS Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 15/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.2.7 MDB Slave iUC180 contactless reader unit can be connected by MDB slave. The connector type is MDB 6 pins (Mini – Fit series 87827 (MOLEX)). iUC180 is powered on the MDB connectors by power supply 12 to 30V DC (30V is a maximum). Pin N° Function Vin GND NC MDBS_RXD MDBS_TXD MDBS_COMMUN A ferrite B & F ELECTRONICS CO., LTD. ref MD-05-265C or equivalent must be added on the power cable. 1.3.1.2.8 MDB master (optional) The iUC180 contactless reader unit can be connected by MDB master if option available. The connector type is MDB master 8 pins (Mini – Fit series 87827 (MOLEX)). iUC180 does not support EXE power supply. A Würth ferrite ref 74271222 or equivalent must be added with two turns on the cable. Pin N° Function NC NC NC NC MDBM_RXD ISO_GND MDBM_TXD ISO_GND Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 16/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.2.9 Wake-Up Jack This connector is used for Wake-up mechanism. Pin N° Function GND HZ Stand-by authorized “0” Wake-up / Stand-by unauthorized The specific jack and cable is a spare part, contact commercial service to purchase it. 1.3.1.2.10 Bluetooth (optional) When the iUC180 contactless reader is ordered with Bluetooth option, it must be connected to an external Bluetooth antenna. Ingenico can provide an antenna, or a standard one can be used. This standard Antenna must have an impedance of 50 Ohm and a maximum gain of 0 dBi. Ingenico recommended antennas: Antenna type bipolar manufacturer EAD Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 model gain FBTS35024SM-ST 0dBi 17/70 impedance 50ohm Minimum Ingenico cable Reference length 192023282 Copyright © 2012 Ingenico All rights reserved 1.3.1.2.11 GPRS (optional) When the contactless reader unit is provided with GPRS functionality (configuration upon request), the external antenna is not provided with the unit. Ingenico can provide an antenna, or a standard one can be used. This standard Antenna must have an impedance of 50 Ohm and a maximum gain of 3.5 dBi. The SIM used for GSM functionality must be assigned to SIM slot. Ingenico recommended antennas: Antenna type manufacturer bipolar AMPHENOL 90-00234 1.7dBi 50ohm 179900131 bipolar HIRSHMANN MCA 18 90 MP 2.1dBi 50ohm 2.5m 189968573 bipolar Giga concept GC300M011-2500 2.2dBi 50ohm 2.5m 189963487 Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 model gain 18/70 impedance Minimum Ingenico cable Reference length Copyright © 2012 Ingenico All rights reserved 1.3.1.3 SAM & µSD Installation 1. 2. 3. 4. 5. 6. Disconnect the iUC180 contactless reader from the main power supply. Open the SAM door by removing the screw. Insert the SAM cards in SAM slot 1 and /or slot 2 Insert µSD card in µSD slot Insert SIM card in SIM slot. Slide the SAM door and screw. SAM cover Screwed with M2X6 T6 Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 19/70 Copyright © 2012 Ingenico All rights reserved SAM Slot 2 µSD Slot SIM Slot SAM Slot 1 Cut angle for GPRS SIM Cut angle for µSD card Cut angle for SAM For SAM/SIM cards, take care of cards orientation and do not push in excess the cards. After insertion, the cards position is 4 mm out of the products as shown on picture. 1.3.1.4 Buzzer The buzzer is controlled by application. The frequency depends of software. 1.3.1.5 RGB backlight The iUC180 has a RGB backlight controlled by applications. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 20/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.6 Contactless LEDs & Contactless Logo The iUC180 contains 4 green LEDs dedicated to Contactless application, and one blue backlighted Contactless logo. Green LEDs Blue backlighted Contactless logo Contactless LEDs are visible from the top Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 21/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.7 Maintenance Button and LED The iUC180 contactless reader has a maintenance button at the back. To enter LLT mode, press the button at power up or at restart, until the red LED lights on. To enter Maintenance mode, press the button at power up or at restart, until the red LED starts blinking. To restart the product, press the button until the blue LED lights on. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 22/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.8 Keypad Remarks: The rear display and the keyboard can only be used in maintenance mode. “*” and “.” are used for Up and Down. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 23/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.9 Cable Protection A cable sealing sleeve is provided with iUC180 to protect the top of product against water runoff. Connect the cables, and snap in the part on the rear cover to cover the cables. This sleeve also holds the antenna tool for GPRS and BT options. Proposed position for cables: Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 24/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.10 Antenna Installation A tool is provided to help screwing the external antenna. 1. Remove the antenna tool from the cable sleeve. 2. Insert the SMA antenna cable through the slot of the antenna tool. 3. Slide the antenna tool over the SMA Cable connector. 4. Screw the cable. The antenna tool has a rest position on the cable sealing sleeve. Antenna tool rest position Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 25/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.11 Grounding connections The grounding connections must respect the following scheme. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 26/70 Copyright © 2012 Ingenico All rights reserved 1.3.1.12 Appearance personalisation 1 Remove the 4 CHC M4 X 10 screws. 2 Dismount the front cover 3 Put the film as shown in the pictures. 4 Screw the front cover with 1mN torque. 6 fixings of the film Film snap in Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 27/70 Copyright © 2012 Ingenico All rights reserved Film Dimensions for iUC180 (2D drawing at your disposal for serigraphic process) Warning: The film must not use metal or conductive ink. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 28/70 Copyright © 2012 Ingenico All rights reserved 1.3.2 iUC150 Front view Rear view 1.3.2.1 Technical Hardware characteristics iUC150 technical characteristics: Mass 550 g Dimensions Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 250 x 120 x 53 mm (67 with cable protection) (height x width x depth) 29/70 Copyright © 2012 Ingenico All rights reserved Operating conditions Functional temperature -20°C,+65°C Max relative humidity 85% at 55°C, non-condensing Fixing Tilt No constraints Power Supply USB 5V Platform Telium2 Functionality Buzzer 500 mA USB device Link RS232 connection only for wake-up mechanism Storage conditions Storage temperature -20°C,+65°C Max relative humidity 85% at 55°C, non-condensing Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 30/70 Copyright © 2012 Ingenico All rights reserved 1.3.2.2 iUC150 output connectors description COM 0 USB 1.3.2.2.1 USB device The iUC150 contactless reader unit can be connected by type B USB. 1.3.2.2.2 Wake-up mechanism iUC150 is design to save power thanks to a “stand-by mode”. To wake-up iUC150 use Wake-up mechanism. Pin 2 of COM0 link drive the wake-up mechanism. Wake-up pin state Hz (high impedance) Stand-by authorized Drive to “0” Wake-up / Stand-by unauthorized The Wake-up pin is drive to “0” by the one asking the wake-up. It could be driven by iUC180 or iUC150 or any devices designed to be compliant (Host device…). Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 31/70 Copyright © 2012 Ingenico All rights reserved Contactless Card Reader iUC 150 PINPad iUP 250 HZ => Stand-by « 0 » => Wake-up USB USB COM0 & 2 COM0 1 - GND 2 - Wake-up 1 - GND 2 - Wake-up HZ => Stand-by « 0 » => Wake-up Any devices design to be compliant. HZ => Stand-by « 0 » => Wake-up 1.3.2.2.3 COM0 link The iUC150 contactless reader unit can be connected to serial port COM0. The connector type is RJ11. Pin N° Function GND Wake-up RXD TXD CTS RTS Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 32/70 Copyright © 2012 Ingenico All rights reserved 1.3.2.3 SAM Installation 1 Disconnect the iUC150 from the main power supply. 2 Open the SAM door by removing the screw. 3 Insert the SAM cards in SAM slot 1 and /or slot 2 4 Slide the SAM door and screw. SAM door Screwed with M2X6 SAM slot2 SAM slot1 Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 33/70 Copyright © 2012 Ingenico All rights reserved Cut angle For SAM/SIM cards, take care of cards orientation and do not push in excess the cards. After insertion, the cards position is 4 mm out of the products as shown on picture. 1.3.2.4 Buzzer The buzzer is controlled by application. The frequency depends of software. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 34/70 Copyright © 2012 Ingenico All rights reserved 1.3.2.5 Contactless LEDs & Contactless Logo The iUC150 contains 4 green LEDs dedicated to Contactless application, and one blue backlighted Contactless logo. Green LEDs Blue backlighted Contactless logo Contactless LEDs are visible from the top Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 35/70 Copyright © 2012 Ingenico All rights reserved 1.3.2.6 Cable Protection A cable sealing sleeve is provided with iUC180 to protect the top of product against water runoff. Connect the cables, and snap in the part on the rear cover to cover the cables. This sleeve also holds the antenna tool for GPRS and BT options. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 36/70 Copyright © 2012 Ingenico All rights reserved 1.3.2.7 Grounding connections The grounding connections must respect the following scheme. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 37/70 Copyright © 2012 Ingenico All rights reserved 1.3.2.8 Appearance personalisation 1 Remove the 4 CHC M4 X 10 screws. 2 Dismount the front cover 3 Put the film as shown in the pictures. 4 Screw the front cover with 1mN torque. 6 fixings of the film Film snap in Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 38/70 Copyright © 2012 Ingenico All rights reserved Film Dimensions for iUC150 (2D drawing at your disposal for serigraphic process) Warning: The film must not use metal or conductive ink. 1.3.2.9 Contactless reader iUC150 and i9500 interconnectivity Connection between the iUC150 and i9500 is done through RS232. Plug the RS232 cable on iUC150 and i9500 with an Ingenico RS232 cable. Use the power supply and cable adapter to power the iUC150. RS232 iUC150 Kit (296138220) contains: PACK BA MULTI EU/US/UK 5V 1A JACK SP Serial cable Adapter cable USB B iUC150 192011323 296137294 296135469 Warning : iUC150 have to be grounded to respect EMC. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 39/70 Copyright © 2012 Ingenico All rights reserved 1.4 PROFESSIONAL INSTALLATION REQUIREMENT Ingenico only sells its products, to qualified partners and integrators. They are in charge of professionally resell, integrate, and install these products inside complete solution for end customers. These end customers solution can be: • Petrol station. • Ticketing kiosk (Airline tickets, cinema, transport, etc.) • Vending machine operator • Parking kiosk (On / off street) • Other Thus, the general public cannot purchase Ingenico hardware or software. Partners, resellers, and Integrators must have qualified electronics engineers to be able to install or integrate our products. Furthermore, they must follow a specific technical training conducted by Ingenico technical experts. In addition installation must follow Ingenico recommendations, as describe in this document, in order to respect: • Local regulations for Electrical Safety and Radio emission levels • Ferrite beam installation Our field support & maintenance engineers are available for follow up and commissioning of installation. 2 MAIN ACCESSORIES 2.1.1 Generality For a complete description of Ingenico Accessories, please refer to iUN accessories catalog. 2.1.2 Optional USB cable An optional USB cable (spare part reference 296129367) with short right-angle overmolded connectors can be purchased as an accessory. This cable is designed to optimize the required volume for iUC180 & iUC150 installation in the kiosk and allows the use of the cable sleeve. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 40/70 Copyright © 2012 Ingenico All rights reserved 2.1.3 iUC150 Power supply Ingenico power supply can be ordered under reference 192017549 (only for 0 to 40°C use) Input: Main voltage supply ranging from 100V to 240V Maximum current of 3A Working frequency range between 47Hz and 63Hz Output: Regulated DC voltage 12V 2.1.4 Serial cable Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 41/70 Copyright © 2012 Ingenico All rights reserved 2.1.5 Adapter cable 2.1.6 LLT cable Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 42/70 Copyright © 2012 Ingenico All rights reserved 2.1.7 Stand-by management cable Definition of the jack connector: Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 43/70 Copyright © 2012 Ingenico All rights reserved 3 IUC180/IUC150 SOFTWARE The system unit, equipped with Telium2® technology, is designed with a structure supporting several applications without any mutual interference. The operating system is a multi-task, real time, preemptive system. The inputs and outputs are managed by interrupts. This provides for simultaneous processing of peripherals, thus increasing system unit performance. It is downloadable to FLASH memory. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 44/70 Copyright © 2012 Ingenico All rights reserved 3.1.1 Software Architecture Power up In Grey : On iUC 180 only Bootstrap Resident loading System Operating system Local loading Memory Contactless USB COM SAM Ethernet µSD GPRS Display MDB Keypad Bluetooth Telium manager UCMC Application manager UCM component Local diagnostics Remote diagnostics Downloading Applications Transaction Flow USB slave/ PSU 5V Management CB Appli Appli 2 Appli 3 Appli n The software architecture is divided into levels: • System • Multi-application manager • Universal Controller Module Component (UCMC) for iUC180 • Independent applications for iUC180 Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 45/70 Copyright © 2012 Ingenico All rights reserved The system manages access to all the terminal’s peripherals. Access is achieved through standard C primitives for all the input/output peripherals (keypad…) and through specific primitives for the other peripherals (smart cards and magnetic stripe cards). Further, the system takes charge of memory management. It allocates memory space to the software applications and access control. The multi-application manager is the entity, which calls the various applications downloaded in the terminal in response to the various events that occur in the terminal. The UCMC component interfaces between the applications and the peripherals (PINPad, Reader, Printer…). This makes the applications independent of the peripherals. It can also manage the « transaction flow ». The applications are modeled around the demands made by the multi-application manager. Each request or input point represents a processing operation to be performed. Each application manages the execution of these processing operations according to its specifications. This standardization based on input points simplifies the implementation of the applications on terminals. The terminal provides natural access to the modularity concepts and improves the maintainability and quality of the applications. 3.1.2 Secure management of software The terminal is designed to execute authentic software only and to do this in a ranked context. The terminal performs the following checks: 1. During a software download, the terminal checks : • Its authenticity, by checking its signature with the RSA algorithm with a 2048 bit key. 2. Before running a software, the terminal checks : • Its presence by looking for the software’s identity. • Its integrity by checking checksums and CRCs. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 46/70 Copyright © 2012 Ingenico All rights reserved 3.1.3 Operating system Bootstrap Bootstrap is resident. The bootstrap very briefly takes control of the terminal after each power up to perform the initialization and the self-test. Then, it automatically runs the operating system, which in turn starts the applications manager. Thus, the Bootstrap provides the following functionalities: • Memory and checksum self-test • Local download of the operating system if absent • Operating system authenticity check and start-up. Operating system characteristics The operating system is downloaded (locally or remotely) into the memory. It is upgradeable. After a few fractions of a second following a power-up, the operating system takes control. It checks the presence, integrity and authenticity of the system components and application software present in the terminal. The maintenance sub-system takes control in the following cases: • if no authentic application is present, • or, if a manual action is made by the operator during power up, • or, if it is activated by an application. The maintenance sub-system ensures, among other things, the downloading of the application software. The operating system ensures the start of the multi-task core and then runs the applications by making a set of services available to them: • • • • • • Multi-task management: Availability of a pre-emptive real-time environment, based on interruptions, events and mailboxes. This management enables simultaneous processing, which improves the terminal’s performance. Input/Output management: This is carried out under interruptions, generally in buffered mode. Thus, the application developer enters a “conventional” C context. System alarm management: Certain incidents detected by the operating system are recorded. They can be used later by the maintenance sub-system during remote or local diagnostics. Application alarm management: A number of incidents detected by the applications can be saved by the operating system at their request. This recording is used later as in the case of system alarms. Application isolation management: The operating system provides the mechanisms described in the section on software isolation and memory protection. Inter-application isolation is managed by the Memory Management Unit (MMU). Application download management: The operating system offers the downloading services described in the « Software download » section. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 47/70 Copyright © 2012 Ingenico All rights reserved 3.1.4 TELIUM MANAGER on iUC180 only The main functions offered by the manager are the following: • Application management • Terminal initialization • Terminal maintenance • Card Recognition and routing to the applications When the EMV DC module is present, it selects the applications: • EMV applications (EMV level 2 compliant) • Non-EMV applications In France, it is compatible with the following environments • Health system • French banking system • "Private applications" Terminal initialization Required operating conditions For iUC150: To operate, the system unit has to be equipped with its system and the application manager. For iUC180: To operate, the system unit has to be equipped with its system, the application manager, the UCMC and at least one application. If no application is initialized, the application manager displays a message requesting initialization for an application (in maintenance mode). If at least one application is initialized, the terminal is operational. The application manager then waits for an event to poll the applications loaded in the terminal. Initialisation of common parameters (iUC180 in maintenance mode) The application manager is used to initialize the common parameters: Date, time, message display language, IP network configuration data, local loading or remote diagnostics. System unit maintenance (iUC180 in maintenance mode) The system unit has maintenance functions. • Properties • Local downloading • Diagnostics Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 48/70 Copyright © 2012 Ingenico All rights reserved Properties The properties function is used to obtain the following information: • List of applications loaded in terminal, version number, checksum, etc. The application manager gives this information for itself and for the operating system. • Application call time: remote collection, loading, etc. • Total number of transactions in each application file contained in system unit. Download The downloading function uses the information supplied on initialization of the application manager. The program update function is used to update the system unit by: • Using a special local loading tool connected to the terminal, • Using a remote loading tool, • Using a USB key. The iUC180 must be in maintenance mode with a USB key containing the software to load plugged in. Then, launch the download by using the manager menu Diagnostics The diagnostics function is used for: • Local diagnostics The operator can request the incidents or alarms stored in the terminal. The storage function implements two sets of elements: o Incident counters: Used for « repetitive » incidents, for which only the number of occurrences is significant. For example, number of power on. o Events: Exceptional in nature. The information content depends on the type of incident. Generally, this comprises the date, time and information relative to the incident itself. The events are stored in a rotating file where the most recent events are kept. • Remote diagnostics This function is used by the operator to trigger a call to a server to dump the information stored in the terminal. The server thus enriches a database by which it can efficiently monitor a terminal population, or propose services such as preventive maintenance, operating statistics, etc. • Diagnostics by USB key (iUC180 only) Diagnostic files are copied to a USB key if present at start-up. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 49/70 Copyright © 2012 Ingenico All rights reserved 3.1.5 Software downloading Downloading The software can be downloaded: • • • Locally via the serial link (COM or USB). Remotely, via the switched telephone network (PSTN) using an external modem, Ethernet, GPRS, TCP/IP network. By a USB key. The iUC180 must be in maintenance mode with a USB key containing the software to load plugged in. Then, launch the download by using the manager menu. The techniques used: • • • • Data compression, Authenticity checking, Memory allocation management, TCP/IP, best optimize the software downloading operations. These features provide faster downloading time, enhanced security, an ease in upgrading, and a larger number of software installed on the system unit. Local Loading Tool (LLT) The LLT is used for local software download. The LLT is formed by: • A PC running with Windows Seven, Vista Pro, XP, 2003 Server, 2000 Professional SP2 • A INGENICO loading software, • A PC-terminal connecting cable Local loading is performed: • From a PC equipped with the Local Loading Tool (LLT) on the COM serial or slave USB link • By automatic switching to the local loader of the operating system. Two connections are possible: • By COM link: Speed 115200 bits/s • By slave USB link: Speed 8 Mbits/s approx. Selection of the software to be loaded is guided on the PC screen by an Explorer type Windows system (Windows loader). Loading time for a 1Mo application is 4s by USB port. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 50/70 Copyright © 2012 Ingenico All rights reserved Loading by USB key (iUC180 only) With the USB key loading method, the software is loaded locally with no need for a PC type tool. The loading time is identical to that of the USB. Terminal Management Server (TMS) For a complete description of the TMS possibilities, refer to the "TMS" section. Loading and management of memory space in system unit Before a (down)load, the system ensures that the necessary memory space is available. The software (possibly compressed) are downloaded to flash. If software is deleted, the system frees the space. If software is upgraded, the system loads the new software, checks it, and deletes the old version. The entire memory area is used and is usable. No area is reserved for upgrades. On start-up of the terminal (power up or reset), the applications are decompressed and the code is copied to RAM. Improved software downloading Includes the following characteristics: Softwares are loaded by FTP TCP/IP and PPP for optimized loading. • • • • • • • Downloading performance in V32bis is around 1.4 kbps on the original files. Once the connection is set up with the V32bis modem, a 120 Kbytes application is downloaded in around 1 minute. Automatic dialling and access to downloading server by switched telephone network (STN) or by X25 (TRANSPAC, in France) using a public PAD or private PAD access. Downloading can be performed in IP mode via Ethernet via a secure channel (SSL). Data is compressed in accordance with an algorithm derived from the LempelZiv method ensuring compression rates of the order of 40 %. For downloading, only the improved application will be downloaded. This management function is handled by the system unit itself and not by the remote server, providing enhanced functional security in a multiple source loading context. Recovery management in the event of loss of communication. This service resumes the downloading which has been interrupted at the exact location where the interruption took place, so that only the missing portion is downloaded when the communication is recovered. The downloaded software is run in a secure context by authenticity check. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 51/70 Copyright © 2012 Ingenico All rights reserved Downloading Starting The downloading can be requested: • Using the application manager on maintainer request. This is the case, in particular, where a program upgrade is concerned or when a new software is added in the terminal memory. In this case, the procedure is simplified to the utmost. The user triggers the call from the application manager by choosing the upgrade function in the menus and using the dialogue keys. Connection to the server takes place automatically. For an upgrade, the user has nothing to enter. To request a new software, the user is guided on the screen in making his choice. The identity of the business is not requested. The identity stored in the system unit is automatically transmitted to the server. • Using the application software on request by the center or merchant (Example: in France, by « envelopes"). In this case, downloading takes place entirely automatically. The downloading ticket informs the merchant. Local loading procedure on: iUC180 iUC150 Trigger the LLT software on the PC Switch off the product Connect the PC to the COM or slave USB Insert the LLT cable in the COM port of the connector. iUC150. Press the rear button and switch on the Connect the PC to the slave USB iUC180. connector. When the LED near the button becomes fix Wait 3 seconds. red, release the button. “LLT” text is now displayed on screen. Trigger the LLT and follow the instructions given in the « LLT User’s guide v4 » to load the software. The parameter definition files must be placed in the "HOST" directory. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 52/70 Copyright © 2012 Ingenico All rights reserved 3.1.6 Development station (iUC180) Introduction With this development station, it is possible to develop application software for the entire range of iUN products. The software is written in high level C language in a multi-application environment. Ingenico provides the complete set of software and the equipment required for development. This also includes the documentations. Training sessions can also be proposed. Required Configuration The development station executes on a Pentium PC running under Windows 2000/XP/Vista/Seven. Development tools for ARM such as a cross-compiler are required. These comprise: • A C compiler (GNU), an assembler and a link editor for ARM and Thumb, • A development environment, • A remote debugger. Supply The SDK 30 development station comprises: • • • • The user license for the M²OS software which includes: o The operating system, o The application manager, o The libraries o The associated documentation in PDF format The user license for the Software Authentication Tool (SAT) software, The user license for the Local Loading Tool (LLT), The card reader and the RSA cards used to sign the applications. SDK + Add On Unattended For iUC180: minimum configuration SDK 9.2 and Add-On Unattended 3.1 are required Associated services • Training Development of applications on iUN Duration: 1 day Location: R&D center. • Pre-requisites for training: A good understanding of the C language is required. Familiarity with firmware can be useful. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 53/70 Copyright © 2012 Ingenico All rights reserved • Technical support Duration: 6 months after the training This includes the hot line, and updates to the documentations and softwares during this period. • Software package A set of software packages, used to simplify development of applications (EMV level 2, contactless…) is available. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 54/70 Copyright © 2012 Ingenico All rights reserved 4 TERMINAL MANAGEMENT SYSTEM (IUC180) 4.1 INTRODUCTION Ingenico developed its own Terminal Estate Management System called IngEstate. It is a link between an organisation with an estate of payment terminals and their merchants. It allows users to remotely manage payment terminals, modify their software content and interact with merchants. 4.2 BASIC FUNCTIONS • • • • • The basic functions are: be able to locally download software on a terminal using a direct cable link (usually RS232); be able to remotely download software on a particular terminal using modems and IP connections; be able to remotely download applications and configuration updates to a large estate of terminals; be able to upload terminal configurations and check software status; Be able to inform merchants when terminals are out of use during maintenance periods. 4.3 ADVANCED FUNCTIONS The advanced functions are extremely various, with new ones being requested frequently: • draw statistics and reports about terminal configurations; • optimise automatic call scheduling/download balancing for large estates of terminals; • be able to display written messages on the terminal, using the display or the printer; • be able to easily configure a complete terminal (i.e. several applications) and to download it in one operation; • be able to analyse the status of terminal software and do only delta downloads (i.e. only the parts that are damaged or need updates); • be able to download to either a Peripheral or a terminal when connected; • Customise the system easily; • Integrate with systems such as SAP easily; • … and many others. 4.4 CUSTOMERS SAVINGS WITH INGENICO TMS SOLUTION The most obvious cost saving is not having to send a technician to service the terminal at the merchant location. Many other costs savings are derived from the ability to have a “clean” estate; better diagnostics and remote software repairs mean less shipping of replacement terminals, less downtime, less mail and phone communication costs, more efficient update campaigns, etc. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 55/70 Copyright © 2012 Ingenico All rights reserved 5 INSTALLATION PROCEDURE IN KIOSKS Note: It is required to use ESD-protective clothing while handling these devices. 5.1 KIOSK MECHANICAL REQUIREMENTS The kiosk panel can be metallic or plastic. The kiosk panel can be coated with painting but grounding of iUN modules must be insured. The kiosk panel thickness must be between 2 mm and 5 mm. This is very important for Contactless performance. With a metallic kiosk panel more than 5mm thick or with metal parts near the antenna, the performance may not be correct. Metallic front plane Plastic or metallic kiosk plane Metallic part should not exceed corner marks 5.2 GENERAL INSTALLATION RECOMMENDATIONS Installation requirements: • Ensure that you have enough free space for installation, operational and maintenance needs. • Be aware of the safety regulations. • Carefully consider the general and local payment security requirements and any impact they may have on the kiosk. • Carefully consider the ergonomic aspects and also the local acts or recommendations concerning disabled and visually impaired people. • See environmental specification and especially in case of very cold or humid weather, take steps to ensure that the internal temperature is at least -20 °C. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 56/70 Copyright © 2012 Ingenico All rights reserved 5.3 KIOSK SUGGESTED LAYOUTS FOR IUC150 IUR250 IUP250 Some propositions are provided by ingenico to optimise unattended modules integration. See specific document “iUP250 iUR250 integration guide”. 6 ASSEMBLY PROCEDURE FOR IUC180 AND IUC150 6.1 KIOSK MINIMUM VOLUME FOR IUC180 The iUC180 requires a minimum volume inside the kiosk. It is detailed in the drawing below. 3D design on demand. The minimum volume is 120 mm width x 134 mm height x 39 mm deep. Picture of iUC180 minimum volume Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 57/70 Copyright © 2012 Ingenico All rights reserved 6.2 KIOSK MINIMUM VOLUME FOR IUC150 The iUC150 requires a minimum volume inside the kiosk. It is detailed in the drawing below. 3D design on demand. The minimum volume is 120 mm width x 134 mm height x 27 mm deep. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 58/70 Copyright © 2012 Ingenico All rights reserved 6.3 KIOSK PREPARATION FOR IUC150 OR 180 NEW INSTALLATION iUC150 and iUC180 use EVA mounting standard. It requires a cut out in the kiosk to the dimensions detailed in the diagram below (all dimensions are in millimeters). The drawing below shows the footprint of iUC150/iUC180 products. CAUTION: It is important that the iUC150/iUC180 footprint surface on the kiosk must be flat and cleared of any holes and burrs to prevent from dust and water penetration in the kiosk. (IP64 standard) 3D step files are also available upon request. Fixing must be done by 4 M4x16mm welded studs. Drawing of the cut-out for the iUC150 or iUC180 3D design on demand. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 59/70 Copyright © 2012 Ingenico All rights reserved 6.4 INSTALLING THE IUC150/IUC180 IN NEW KIOSK iUC150/iUC180 requires standards hexagonal nuts for integration into a kiosk. Screw the 4 nuts M4 with a 1.0 N.m torque. It is recommended to use washers. Picture showing a new installation of the iUC180 or iUC150 Mounting with 6 studs is possible. The two middle studs will not be screwed. For connectors access, limit the stud length at Lmax = 11.5mm on both back studs L max of the 2 back studs Installation of the iUC180 or iUC150 with 6 studs position Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 60/70 Copyright © 2012 Ingenico All rights reserved 6.5 CONNECTING THE IUC180 OR 150 TO THE KIOSK GROUND Ground studs to connect copper braid to ground. Picture showing the grounding of the iUC180 To insure good connexion of iUC180 or iUC150 to the kiosk ground, it is recommended to install one copper braid connecting the 2 grounding studs and connect this braid to the chassis. Kiosk mechanical requirements See chapter 5.1 Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 61/70 Copyright © 2012 Ingenico All rights reserved 7 MAINTENANCE 7.1 CONFIGURATION The iUC180 & iUC150 supplied to you has operational configuration loaded. In factory, software is loaded in the iUC180 & iUC150, as well as parameter definition files. For iUC180: The parameter definition file of the UCMC component is used, in particular, to determine the type of printer used (local/host) and the position of the host (COMx). To change configuration, you must load a new parameter definition file (supplied by Ingenico). This operation can be performed using the LLT or a USB key (see § Loading by USB key) For more information concerning configuration, contact Ingenico Technical Support. 7.2 OPERATING LIFE Minimum operating life of 5 years. 8 CLEANING INSTRUCTIONS The external front face of the contactless reader should be carefully cleaned on a regular basis. First of all, unplug all the wires from the terminal during this operation. Good rules for proper cleaning of the terminal are: • • • • • • Use a soft cloth that is very slightly soaked with soapy water to clean the outside of the terminal. The glass has special surface treatment but must be carefully clean. Do not clean the electrical connections. Do not use in any case, solvents, detergents or abrasive products: Those materials might damage the plastic or electrical contacts. Avoid also the use of pressurized liquids. Avoid exposing the terminal to the direct rays of the sun. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 62/70 Copyright © 2012 Ingenico All rights reserved 9 DISASSEMBLING THE PRODUCTS ACCORDING TO WEEE DIRECTIVE 9.1 IUC180 END-OF–LIFE DISASSEMBLY INSTRUCTIONS This document is intended for treatment and recycling facilities. It provides the basic instructions for the disassembly of Ingenico products to remove components and materials requiring selective treatment, as defined by EU directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE). Ce document est destiné aux installations de traitement et de recyclage. Il fournit les instructions de base pour le démontage de produits Ingenico afin de retirer les composants et matériaux nécessitant un traitement sélectif, tel que défini par la directive européenne 2002/96/CE, sur les Déchets d’Equipements Electriques et Electroniques (DEEE). 1. MODELS AND DESCRIPTIONS MODÈLES ET DESCRIPTIONS Products covered by this disassembly instructions. Produits concernés par ces instructions de démontage. Product Name Product description Product mass (g) Nom du produit IUC180 Description du produit Unattended payment PINPad Masse du produit (g) 680g 2. COMPONENTS AND MATERIALS REQUIRING SELECTIVE TREATMENT COMPOSANTS ET MATERIAUX NÉCESSITANT UN TRAITEMENT SÉLECTIF The following components and materials, if present in the Ingenico product(s), have to be removed and selectively treated. Les composants et matériaux suivants, si présents dans le(s) produit(s) Ingenico, doivent être retirés et faire l’objet d’un traitement sélectif. Quantity included in product(s) Components and materials ICO-ETU-11-1858-CL-V1 Composants et matériaux Quantité contenue dans le(s) produit(s) Capacitors containing Polychlorinated biphenyls (PCB) Condensateurs contenant du polychlorobiphényle (PCB) Components containing Mercury, such as switches or backlighting lamps Composants contenant du mercure, tels que les interrupteurs ou les lampes à rétroéclairage Batteries Piles et accumulateurs Printed circuit boards greater than 10 cm² Cartes de circuits imprimés de plus de 10 cm² Toner cartridges Cartouches de toner Plastic containing brominated flame retardants Matières plastiques contenant des retardateurs de flamme bromés Asbestos waste and components which contain asbestos Déchets d'amiante et composants contenant de l'amiante Cathode ray tubes Tubes cathodiques Chlorofluorocarbons (CFC), Hydrochlorofluorocarbons (HCFC) or Hydrofluorocarbons (HFC), Hydrocarbons (HC) Chlorofluorocarbones (CFC), hydrochlorofluorocarbone (HCFC) ou hydrofluorocarbone (HFC), hydrocarbures (HC) Gas discharge lamps Lampes à décharge Liquid crystal displays (LCD) of a surface greater than 100 cm² and all those back-lighted with gas discharge lamps Écrans à cristaux liquides (LCD) d'une surface supérieure à 100 cm² et tous les écrans rétroéclairés par des lampes à décharge Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 63/70 4max (2 + 2) Copyright © 2012 Ingenico All rights reserved External electric cables Câbles électriques extérieurs Components containing refractory ceramic fibres Composants contenant des fibres céramiques réfractaires Components containing radioactive substances Composants contenant des substances radioactives Electrolyte capacitors measuring greater 2,5 cm in diameter or height Condensateurs électrolytiques mesurant plus de 2,5 cm de diamètre ou de hauteur 3. PRODUCT DISASSEMBLY PROCESS PROCESSUS DE DEMONTAGE DU PRODUIT Basic steps to remove components and materials previously identified and requiring selective treatment. Etapes de base pour retirer les composants et matériaux précédemment identifiés et nécessitant un traitement sélectif. Step Etape Product disassembly process Processus de démontage du produit Remove the 4 screws of front casing and of the rear cover Oter les 4 vis du caport avant et du capot arrière Remove the cover, remove the FPC Oter le capot, ôter le FPC. Remove the 4 screws on the extension card. Lift the card, disconnect the FPC below. Remove the extension card. Oter les 4 vis sur la carte d’extension, Soulever la carte d’extension et déconnecter le FPC dessous. Oter la carte extension. Remove the battery from extension card Oter la pile de la carte extension. Remove the 4 screws on the plastic spacer. Remove the plastic spacer, the rear metal plate, the plastic antenna holder Oter les 4 vis maintenant l’entretoise plastique. Oter l’entretoise plastique, puis la tôle arrière, puis le support plastique de l’antenne Remove the keypad card and the displays. Oter la carte clavier et les afficheurs Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 64/70 Copyright © 2012 Ingenico All rights reserved 9.2 IUC150 END-OF–LIFE DISASSEMBLY INSTRUCTIONS This document is intended for treatment and recycling facilities. It provides the basic instructions for the disassembly of Ingenico products to remove components and materials requiring selective treatment, as defined by EU directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE). Ce document est destiné aux installations de traitement et de recyclage. Il fournit les instructions de base pour le démontage de produits Ingenico afin de retirer les composants et matériaux nécessitant un traitement sélectif, tel que défini par la directive européenne 2002/96/CE, sur les Déchets d’Equipements Electriques et Electroniques (DEEE). 4. MODELS AND DESCRIPTIONS MODÈLES ET DESCRIPTIONS Products covered by this disassembly instructions. Produits concernés par ces instructions de démontage. Product Name Product description Product mass (g) Nom du produit IUC150 Description du produit unattended electronic payment reader Masse du produit (g) 550g 5. COMPONENTS AND MATERIALS REQUIRING SELECTIVE TREATMENT COMPOSANTS ET MATERIAUX NÉCESSITANT UN TRAITEMENT SÉLECTIF The following components and materials, if present in the Ingenico product(s), have to be removed and selectively treated. Les composants et matériaux suivants, si présents dans le(s) produit(s) Ingenico, doivent être retirés et faire l’objet d’un traitement sélectif. Quantity included in product(s) Components and materials Composants et matériaux Quantité contenue dans le(s) produit(s) Capacitors containing Polychlorinated biphenyls (PCB) Condensateurs contenant du polychlorobiphényle (PCB) Components containing Mercury, such as switches or backlighting lamps Composants contenant du mercure, tels que les interrupteurs ou les lampes à rétroéclairage Batteries Piles et accumulateurs Printed circuit boards greater than 10 cm² Cartes de circuits imprimés de plus de 10 cm² Toner cartridges Cartouches de toner Plastic containing brominated flame retardants Matières plastiques contenant des retardateurs de flamme bromés Asbestos waste and components which contain asbestos Déchets d'amiante et composants contenant de l'amiante Cathode ray tubes Tubes cathodiques Chlorofluorocarbons (CFC), Hydrochlorofluorocarbons (HCFC) or Hydrofluorocarbons (HFC), Hydrocarbons (HC) Chlorofluorocarbones (CFC), hydrochlorofluorocarbone (HCFC) ou hydrofluorocarbone (HFC), hydrocarbures (HC) Gas discharge lamps Lampes à décharge Liquid crystal displays (LCD) of a surface greater than 100 cm² and all those back-lighted with gas discharge lamps Écrans à cristaux liquides (LCD) d'une surface supérieure à 100 cm² et tous les écrans rétro éclairés par des lampes à décharge External electric cables Câbles électriques extérieurs Components containing refractory ceramic fibres Composants contenant des fibres céramiques réfractaires Components containing radioactive substances Composants contenant des substances radioactives Electrolyte capacitors measuring greater 2,5 cm in diameter or height Condensateurs électrolytiques mesurant plus de 2,5 cm de diamètre ou de hauteur Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 65/70 Copyright © 2012 Ingenico All rights reserved 6. PRODUCT DISASSEMBLY PROCESS PROCESSUS DE DEMONTAGE DU PRODUIT Basic steps to remove components and materials previously identified and requiring selective treatment. Etapes de base pour retirer les composants et matériaux précédemment identifiés et nécessitant un traitement sélectif. Step Etape Product disassembly process Processus de démontage du produit Remove the 4 screws of front casing and of the rear cover Oter les 4 vis du caport avant et du capot arrière Remove the cover Oter le capot Remove the 4 screws on the extension card. Lift the card, disconnect the FPC below. Remove the extension card. Oter les 4 vis sur la carte d’extension, Soulever la carte d’extension et déconnecter le FPC dessous. Oter la carte extension. Remove the battery from extension card Oter la pile de la carte extension. Remove the 4 screws on the plastic spacer. Remove the plastic spacer, the rear metal plate, the plastic antenna holder Oter les 4 vis maintenant l’entretoise plastique. Oter l’entretoise plastique, puis la tôle arrière, puis le support plastique de l’antenne Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 66/70 Copyright © 2012 Ingenico All rights reserved 10 STANDARDS 10.1 IUC 150 ELECTRICAL CONSUMPTIONS • Average consumptions device waiting for host solicitation (5 VDC input.): - Less than 50 mA Value measured for Power supply 5V at 25°C • Maximum average external supply current (5 VDC input.): - Less than 500 mA Value measured for Power supply 5V at 25°C • Maximum consumption in stand-by mode (5 VDC input.): - Less than 50µA Value measured for Power supply 5V at 25°C 10.2 IUC 180 ELECTRICAL CONSUMPTIONS • Average consumptions device waiting for host solicitation (12 VDC input.): - Less than 120 mA Value measured for Power supply 5V at 25°C • Maximum average external supply current (12 VDC input.): - Less than 2500 mA Value measured for Power supply 5V at 25°C • Maximum consumption in stand-by mode (12 VDC input.): - Less than 400 µA Value measured for Power supply 5V at 25°C 10.3 TEMPERATURE AND HUMIDITY • Operating & Storage conditions : o Relative humidity: 5% to 85% non-condensing. o External temperature range: -20 °C to 65 °C. 10.4 ENVIRONMENTAL SPECIFICATION CONTINUED • Operating conditions : o Front face shock resistance: IK10 o Vibrations resistance: 5-9Hz, 6.2mm; 9-200Hz, 1g; 200-500 Hz, 1.5g; 10ct/mn, 10 Cycles o Bumps resistant: 6ms, 25g, 500 cycles each direction • Natural events: o Water and dust resistant IP64 for iUC180 and iUC150 (outside the kiosk). Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 67/70 Copyright © 2012 Ingenico All rights reserved • Drop: o Drop 1m on concrete surface all faces 10.5 EC STANDARD COMPLIANCE MARKING EC standard compliance marking certifies that the product stipulated below: iUC180 iUC150 Conforms to the following harmonized standards: • IEC/EN 60950-1: Electrical safety of data processing equipment including electrical office equipment. Issue dec. 2001 • EN 55022: Data processing equipment – Radiofrequency disturbance characteristics - Limits and measurement methods. EN 55022 2006 + A1 (2007) • EN 55024: Data processing equipment – Immunity characteristics - Limits and measurement methods. Issue 1998 + A1- 2001 + A2 – 2003 10.6 IC STATEMENTS This class (B) digital apparatus complies with Canadian ICES-003. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication." Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. "This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device." Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 68/70 Copyright © 2012 Ingenico All rights reserved This radio transmitter (2586D-IUC18XWD) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio (2586D-IUC18XWD ) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. 10.7 FCC STATEMENT FCC standard compliance marking certifies that the product stipulated below: iUC180 iUC150 • conforms to the following harmonized standards : – part 15 subpart B of the FCC rules This class (B) digital apparatus complies with Canadian ICES-003. Information to users: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. This device complies with FCC and IC radiation exposure limits set forth for general population. This device must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 69/70 Copyright © 2012 Ingenico All rights reserved 10.8 ENVIRONMENT (WEEE, BATTERIES AND PACKAGING) This product is labeled in accordance with European Directives 2002/96/EC concerning Waste Electrical and Electronic Equipment (WEEE) and 2006/66/EC concerning Batteries and Accumulators. Those provisions are requiring producers and manufacturers to become liable for take-back, treatment and recycling upon end of life of equipment and batteries. The associated symbol means that WEEE and waste batteries must not be thrown away but collected separately and recycled. Ingenico ensures that efficient collection and recycling schemes are set-up for WEEE and batteries according to the local regulation of your country. Please contact your retailers for more detailed information about the compliance solution in place for disposing of your old product and used batteries. Packaging waste must also be collected separately to assure a proper disposal and recycling. *296146 392* Please note that proper recycling of the electrical and electronic equipment and waste batteries will ensure safety of human health and environment. Intégration Guide_iUC150&iUC180 900009816 R11 000 01/1223 70/70 Copyright © 2012 Ingenico All rights reserved
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 70 Producer : GPL Ghostscript 8.54 Create Date : 2012:08:28 11:10:26+02:00 Modify Date : 2012:08:28 11:10:26 Title : 900009816 R11 000 01_296146392_Integration guide_IUC150180_EN_28 08 2012 Creator : PDFCreator Version 0.9.3 Author : ofabregoule Subject :EXIF Metadata provided by EXIF.tools