Innovative Wireless Technologies FAP4215-050 Portable repeater or router for use in an ad-hoc wireless communications network User Manual CERTIFICATE OF COMPLIANCE

Innovative Wireless Technologies, Inc. Portable repeater or router for use in an ad-hoc wireless communications network CERTIFICATE OF COMPLIANCE

User Manual

Download: Innovative Wireless Technologies FAP4215-050 Portable repeater or router for use in an ad-hoc wireless communications network User Manual CERTIFICATE OF COMPLIANCE
Mirror Download [FCC.gov]Innovative Wireless Technologies FAP4215-050 Portable repeater or router for use in an ad-hoc wireless communications network User Manual CERTIFICATE OF COMPLIANCE
Document ID1886371
Application IDAHGKaIfs6llpwXhG++ZxcQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize37.68kB (470968 bits)
Date Submitted2013-01-24 00:00:00
Date Available2013-01-28 00:00:00
Creation Date2013-01-22 16:55:50
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2013-01-22 16:56:10
Document TitleCERTIFICATE OF COMPLIANCE
Document CreatorAcrobat PDFMaker 9.1 for Word
Document Author: Systems Administrator

Rhein Tech Laboratories, Inc.
360 Herndon Parkway
Suite 1400
Herndon, VA 20170
http://www.rheintech.com
Appendix H:
Client: IWT, Inc.
Model #: FAP4215-050
Standard: FCC 15.247
FCC ID: SP8-FAP4215-050
Report #: 2012367
Manual
Please refer to the following pages.
Page 38 of 48
Portable Mesh Node
FAP4215-050
Installation and User Guide
Innovative Wireless Technologies, Inc.
1100 Main Street
Lynchburg, VA 24504
Phone: 434-316-5230 (United States)
Fax: 434-316-5232 (United States)
www.iwtwireless.com (United States)
Revised: 1/14/2013
Approval:
6640-12-0010, Rev.A
Page 1 of 10
Contents
1.
PORTABLE MESH NODE OVERVIEW .............................................................................................................. 3
2.
SAFETY INFORMATION ................................................................................................................................. 3
2.1
2.2
2.3
2.4
PMN INSTALLED ABOVE GROUND ...................................................................................................................3
PMN INSTALLED IN UNDERGROUND COAL MINES ..........................................................................................4
PROXIMITY TO BLASTING COMPONENTS ........................................................................................................5
MODIFICATIONS ..............................................................................................................................................5
3.
SPECIFICATIONS ............................................................................................................................................ 5
4.
USER INTERFACE DESCRIPTION ..................................................................................................................... 6
4.1
4.2
5.
PRIOR TO INSTALLATION .............................................................................................................................. 7
5.1
5.2
6.
INPUTS AND OUTPUTS.....................................................................................................................................6
COMPONENTS NECESSARY FOR INSTALLATION ..............................................................................................7
SITE SURVEY .....................................................................................................................................................7
VISUAL INSPECTION .........................................................................................................................................7
BASIC INSTALLATION INSTRUCTIONS ............................................................................................................ 8
6.1
6.2
INSTALLATIONS BELOW GROUND ...................................................................................................................8
INSTALLATIONS ABOVE GROUND ....................................................................................................................9
7.
OPERATING AND MAINTENANCE INSTRUCTIONS ......................................................................................... 9
8.
WARRANTY INFORMATION ........................................................................................................................ 10
Revised: 1/14/2013
Approval:
6640-12-0010, Rev.A
Page 2 of 10
1. PORTABLE MESH NODE OVERVIEW
Innovative Wireless Technologies’ Portable Mesh Node (PMN) is a transceiver designed for use in
industrial mining applications.
The FAP4215-050 Portable Mesh Node (PMN) is a portable infrastructure device that acts as a repeater
or router in an ad-hoc wireless communications network.
The mesh network supports voice communications, text messaging, and tracking capability of personnel.
High reliability communications is inherent to the self-healing, self-configuring mesh network
architecture by providing redundant communications paths from one device to another. In the event of
any node failure, the system automatically re-routes signals to another device within radio frequency
range.
Under normal operating conditions, the PMN is powered by an internal lead acid battery.
Some key features of the PMN:
• Supports simultaneous Voice/Data/Tracking
• High reliability communications in underground environments
• Supports peer-to-peer communications with other Portable Mesh Nodes
• High quality voice communications with minimal latency
• Intrinsically safe
• Mine Safety and Health Administration I.S. Evaluation No. 23-A-120008-0
2. SAFETY INFORMATION
IMPORTANT! READ BEFORE USING THE PORTABLE MESH NODE.
This section contains important information on the safe operation of the PMN.
2.1
PMN INSTALLED ABOVE GROUND
2.1.1
Part 15 of Federal Communications Commission (FCC) Rules Compliance
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
FCC ID: SP8-FAP4215-050
Revised: 1/14/2013
Approval:
6640-12-0010, Rev.A
Page 3 of 10
When operated above ground, PMN professional installation is required with the following antenna
connected to the 900 MHz RF output port:
Laird Technologies Model No. OD9-5 or equivalent
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate RF
energy which may cause harmful interference to radio communications if not installed and used in
accordance with the instructions. It is important to note that proper installation does not guarantee
interference will not occur. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
•
•
•
•
2.1.2
reorient or relocate the receiving antenna;
increase the separation between the equipment and receiver;
connect the equipment into an outlet on a circuit different from that to which the receiver is
connected; or
Consult the dealer or an experienced radio/TV technician for help.
FCC Allowable Limits for General RF Exposure
CAUTION! To ensure that exposure to RF electromagnetic energy is within the FCC allowable limits for
general RF exposure, always adhere to the following guidelines:
•
The antenna used for the PMN transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
•
The PMN must be installed 20 cm or more from any personnel in order to comply with FCC
exposure requirements.
2.2
PMN INSTALLED IN UNDERGROUND COAL MINES
The Mine Safety and Health Administration (MSHA) has evaluated this device per Title 30 Code of
Federal Regulations Part 23.
MSHA Intrinsic Safety Evaluation Number: 23-A-120008-0
This product has been determined to be intrinsically safe under the following conditions:
• The PMN is installed with one of the following 900 MHz antennas:
1. M-2 Antenna Systems, Inc. Model No. 902-5 or 902-5MA Yagi antenna.
2. ASY-RAT-1000-018 antenna.
•
When installed underground, the PMN may not be connected to line power.
Revised: 1/14/2013
Approval:
6640-12-0010, Rev.A
Page 4 of 10
•
2.3
When installed underground in coal mines, the installed PMN is part of a MSHA approved
system. Follow the PMN installation instructions described in Sections 5.0 and 6.0 as well as any
instructions / documentation applicable to the specific MSHA approved system installation.
PROXIMITY TO BLASTING COMPONENTS
The PMN shall not be turned on or operated within 7.1 feet of explosives or blasting
components. When used in the Commonwealth of Pennsylvania, the PMN shall not be turned
on or operated within 35.5 feet of explosives or blasting circuits.
2.4
MODIFICATIONS
Changes or modifications to the PMN not expressly approved by Innovative Wireless Technologies, Inc.,
may void the user’s authority to operate this equipment.
3. SPECIFICATIONS
(Typical unless otherwise specified)
Environmental
Operating Temperature1
Storage Temperature
Dimensions
Weight
Enclosure
-10C to +50C
-40C to +80C
13.37” x 11.62” x 6.00”
13 lbs
IP5X
Power
Main
Connector
Voltage
Current w/ battery charging
Battery Only Voltage
Current
Souriau Circular MilL/Spec 10 Pin
13V to 26VDC
0.30A avg, 0.37A peak @ 24VDC
5.9V to 7.2VDC
.431 avg, @ 6.9VDC
Electrical
Frequency Range
Receiver Sensitivity2
RF Transmit Power (below ground)
RF Transmit Power (above ground)
RF input/output
Voice channels/PMN3
Data channels/PMN
902 – 928 MHz
-100 dBm
+28 dBm
+13 dBm
50 ohms nominal (N connector)
4 channels
2 channels, 250 kbps
Note 1: Ambient temperature
Note 2: Conducted sensitivity measured at BER <2%
Note 3: Supports four simultaneous voice calls (TDMA)
Revised: 1/14/2013
Approval:
6640-12-0010, Rev.A
Page 5 of 10
4. USER INTERFACE DESCRIPTION
To begin using the PMN review the information below covering the basic information you need to know
to get started.
4.1
INPUTS AND OUTPUTS
The following is an explanation of the PMN inputs and outputs as shown in Figures 1 and 2:
Main DC:
Main power input. Souriau Circular MIL/Spec 10 pin connector receives input from
AC/DC power supply (24 VDC, 3 Amps nominal). A dust cap is used when this connector
is not in use.
LED:
The blue power LED embedded in the switch indicates the status of the PMN and
embedded battery via a designated blink pattern (refer to Section 7.0)
On-Off Switch: The push button switch allows the user to power the PMN on and off to conserve
battery power.
RF Port:
900 MHz output port. Type-N connecter to connect coaxial cables, antennas, and
RF accessories.
Main DC
RF Port
LED
ON/OFF
Switch
Revised: 1/14/2013
Approval:
Figure 1
6640-12-0010, Rev.A
Page 6 of 10
4.2
COMPONENTS NECESSARY FOR INSTALLATION
The PMN installation uses the following components and accessories (refer to Sections 5.0 and 6.0 for
basic installation instructions):
Antenna (900 MHz):
The specific 900 MHz antenna connected to the PMN RF port depends on the location of the PMN.
For Above Ground (FCC Certified) use:
1. Laird Technologies OD9-5 or equivalent
2. Kent Model No. WA5VJB antenna
For Below Ground (MSHA Approved) use:
1. M-2 Antenna Systems, Inc. 902-5 or 902-5MA
2. Kent Model No. WA5VJB antenna
The PMN can only use the antenna models listed in applications that must meet FCC or MSHA
requirements.
RF Power Splitters, Couplers, Attenuators:
The use of 2-way, 3-way, or 4-way power splitters and other RF accessories depends on the specific
PMN system installation configuration. Refer to system installation drawings for approved
configurations.
RF Cable:
The RF coaxial cable connecting the antenna port of the PMN to the 900 MHz antenna is an MSHA
approved flame resistant cable with N-connectors.
5. PRIOR TO INSTALLATION
IMPORTANT! TRAINED PERSONNEL MUST PROFESSIONALLY INSTALL THE PMN.
5.1
SITE SURVEY
Conduct a survey to determine the appropriate sites to install the PMN from an RF perspective.
• Follow MSHA-approved system installation guidelines pertaining to the length of RF cables.
•
Be sure that PMN antennas are installed an appropriate distance away from any blasting
circuits (refer to Section 2.3).
5.2
VISUAL INSPECTION
Each PMN should be visually inspected to ensure the following:
•
The enclosure is free from damage and defects.
Revised: 1/14/2013
Approval:
6640-12-0010, Rev.A
Page 7 of 10
•
The enclosure has all connectors installed.
•
The DC input connector has the proper dust cap installed.
•
Properly secure the enclosure lid with the 2 latches.
6.
BASIC INSTALLATION INSTRUCTIONS
6.1
INSTALLATIONS BELOW GROUND
IMPORTANT! TRAINED PERSONNEL MUST PROFESSIONALLY INSTALL THE PMN.
IMPORTANT! WHEN USED IN AN UNDERGROUND COAL MINING APPLICATION, THE PMN
INSTALLATION MUST BE PART OF A MSHA APPROVED SYSTEM. INSTALLATION OF THE PMN MUST BE
PER REQUIREMENTS SPECIFIC TO THE APPROVED SYSTEM INCLUDING CABLE LENGTHS AND CABLE
TYPES.
At each of the sites determined by the survey described in 5.1:
Antenna Placement
Determine the placements for the 900 MHz antennas to ensure proper RF propagation. The PMN may
connect to multiple 900 MHz antennas via RF power splitters connected to the output of the unit. For
units installed in coal mines below ground, mount the antennas to roof bolts or on the PMN’s magnetic
accessory plate using the magnetic antenna mount. Select locations that ensure proper RF
communication. Antenna location should not present a safety hazard or opportunity for damage to
occur.
PMN Enclosure and RF Splitter Placement
Locate a place to emplace or mount the PMN enclosure and RF power splitter. Choose the appropriate
splitter (2-way, 3-way, or 4-way) for a given PMN antenna configuration. The PMN and splitter
installation should be in a convenient central location in order to minimize the amount of RF cable
needed to connect the splitter box to the antennas. The PMN mounts on a wall, the ceiling or can be
placed on the mine floor. The PMN enclosure orientation is not relevant.
PMN/RF Splitter/Antenna Connection
Connect the PMN 900 MHz output to the splitter and antennas. The PMN connects to the splitter box
with coaxial cable. Connect one end of the cable to the RF output port on the PMN and the other end to
the side of the splitter with only one connector. Connect each of the remaining splitter connections to
an antenna using coaxial cable.
Revised: 1/14/2013
Approval:
6640-12-0010, Rev.A
Page 8 of 10
Applying Power to the System
Before pressing the ON/OFF button, re-check all appropriate clearance distances to blasting circuits
(refer to Section 2.3). If blasting must be done near a PMN, be sure to power the device down. Install
dust caps on exposed battery connector.
Press the ON/OFF button. The power LED on the PMN will start out solid as the PMN boots up.
Verify the power indicator LED on the PMN is indicating a Discharging Battery (ON—10%, OFF—90%). It
may take up to one (1) minute to indicate a Discharging Battery.
IMPORTANT SAFETY WARNINGS!
• CONTENTS OF THE PMN ASSEMBLY INCLUDE A NONSPILLABLE SEALED LEAD ACID BATTERY.
• DO NOT BLOCK THE VENT OPENING NEAR THE HANDLE OF THE ASSEMBLY ENCLOSURE.
• DO NOT CHARGE BATTERY IN INVERTED POSITION (WITH ENCLOSURE HANDLE FACING
DOWNWARD).
• AVOID EXPOSURE OF BATTERY ASSEMBLY TO HEAT. DO NOT PLACE IN CLOSE PROXIMITY TO
HEAT SOURCE WITHOUT PROPER VENTILATION.
6.2
INSTALLATIONS ABOVE GROUND
IMPORTANT! TRAINED PERSONNEL MUST PROFESSIONALLY INSTALL THE PMN.
At each of the sites determined by the survey described in 5.1:
Follow installation instructions of 6.1. Equipment above ground should be located so it does not present
a safety hazard or cause damage. Secure all equipment using the proper hardware.
PMNs installed above ground are not required to be part of a MSHA approved system. MSHA-specific
system restrictions on cable lengths, gauges, and power supplies may not apply.
Follow all FCC guidelines listed in Section 2.0.
7. OPERATING AND MAINTENANCE INSTRUCTIONS
The PMN does not have any direct user interface.
The status of the PMN and its connected backup battery may be monitored by observing the blink
pattern of the indicator LED mounted on the outside of the enclosure:
SOLID ON:
BLINK (ON—50%, OFF—50%):
Revised: 1/14/2013
Approval:
Main DC Power ON / Bad or missing battery
(Also solid during initial power up of device)
Main DC Power ON / Battery Charging
(Charging condition)
6640-12-0010, Rev.A
Page 9 of 10
WINK (ON—10%, OFF—90%):
OFF:
Main DC Power OFF / Battery Discharging
(Normal Use condition)
PMN Power Set to off
The PMN requires little routine maintenance. Inspect each box periodically every month to ensure that
the box remains free of damage and defects. It is important that the box remains dust tight. Replace
defective boxes immediately. Do not continue to use any boxes that may have had their dust seal
compromised.
The PMN may be shut down and disconnected from antennas during maintenance or while being moved
to a new location. When removing PMN power or RF connections, place dust caps on all exposed
connectors.
8. WARRANTY INFORMATION
Disassembling the PMN will void the warranty. If a PMN is damaged, discontinue use.
Revised: 1/14/2013
Approval:
6640-12-0010, Rev.A
Page 10 of 10

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Systems Administrator
Create Date                     : 2013:01:22 16:55:50-07:00
Modify Date                     : 2013:01:22 16:56:10-07:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2013:01:22 16:56:10-07:00
Creator Tool                    : Acrobat PDFMaker 9.1 for Word
Format                          : application/pdf
Title                           : CERTIFICATE OF COMPLIANCE
Creator                         : Systems Administrator
Document ID                     : uuid:54481d2c-096b-4f3d-8e5f-8eecac2cb410
Instance ID                     : uuid:ba969add-00cb-44e6-93d3-e961938e4444
Producer                        : Adobe PDF Library 9.0
Page Count                      : 11
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SP8-FAP4215-050

Navigation menu