Inovonics Wireless 3B6ETICR65 PIR Transmitter User Manual 04098A

Inovonics Wireless Corporation PIR Transmitter 04098A

Users Manual

Download: Inovonics Wireless 3B6ETICR65 PIR Transmitter User Manual 04098A
Mirror Download [FCC.gov]Inovonics Wireless 3B6ETICR65 PIR Transmitter User Manual 04098A
Document ID469115
Application IDLsOLLs0vTm+QR+T9ioIpPw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.44kB (368035 bits)
Date Submitted2004-09-15 00:00:00
Date Available2004-11-05 00:00:00
Creation Date2004-05-28 09:58:24
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2004-05-28 09:58:24
Document Title04098A_.qxd
Document CreatorQuarkXPress(tm) 5.0
Document Author: roger

EchoStream™ Select ES1265
360° Passive InfraRed Motion Detector
Installation and Operation Manual - 04098A
IMPORTANT NOTES
• Products, unless specifically noted, are intended for indoor use.
• Manually test all products regularly.
• These products are designed to be installed and maintained by professional security technicians.
OVERVIEW:
The ES1265 is a wireless, ceiling-mounted 4-element passive infrared intrusion
detector providing protection from intruders by pyro-sensor array. Micro-controller PIR signal analysis with special ASIC technology for PIR pulse processing
increases immunity to RFI, vibration, static, lightning, ambient temperature
changes and other common causes of false alarms.
Battery
Tamper Switch
Reset Button
PIR Sensitivity
Test LED
Walk Test button
Walk Test Reed Switch
Frequency Band Selector
Figure 1
AU (915-928MHz)
EU (868-869 MHz)
LOCATING THE DETECTOR:
Choose a location most likely to intercept an intruder. Refer to the following recommendations:
• Temperature changes: Do not install the detector outdoors or in a place exposed to sudden temperature changes, or
near equipment such as air conditioners, ventilators, fans, heaters, etc.
• Bright light: Avoid bright light, direct or reflected sunlight, automobile headlights or other light sources.
• Moving Objects: Objects that may move or vibrate, such as curtains, window blinds or decorative banners can cause
false alarms.
• Exposure to contaminants: Airborne vapors, mists, steam, or fumes can cause detector malfunction.
• Curtains, Glass, Screens: Infrared energy cannot pass through opaque objects or through transparent or semi-transparent materials such as glass, paper, or curtains. Barriers of these materials create "blind-spots" in intrusion protection.
• Detection Zones: Refer to zone pattern diagrams to determine optimal mounting locations.
NZ (921-928MHz
US (902-928MHz)
MF4232 compatible (915-928MHz)
Figure 2
MOUNTING THE DETECTOR:
1. Remove cover from the detector body by loosening the lock screw about 5mm and turning the cover counterclockwise. (See Figure 3.)
2. Remove the body from the bracket by turning it counterclockwise.
3. Mount the bracket to the ceiling. Hold the bracket on the ceiling. Mark and drill 4 holes for installation.
4. Attach the detector body. Install the battery and place the detector body so that the arrow is aligned with the dot
on the bracket. Turn clockwise until the arrow on the body aligns with the arrow on the bracket. (See Figure 3.)
5. Set Pulse Sensitivity jumper in desired position. Set Frequency Band Selector. (See Figure 1.)
6. Register the transmitter as described below.
7. Attach the cover. Place the four tabs of the cover into the matching notches in the base and turn the cover clockwise until it fits tightly.
Figure 3
MOUNTING HEIGHT
The ES1265 can be mounted to a maximum height of approximately 18 feet (5.5 meters). At 18', the PIR detection pattern
is about twice the diameter of a 10' (3m) installation. As mounting height increases, distance between detection zones also
increases toward the perimeter, and the effects of factors such as floor surface temperature and intruder direction and
speed are intensified. This can contribute to reducing speed of detection. (See Figures 4-6.) Every installation should
include a Walk Test of detection zones, including intrusion paths crossing the edges of the zones.
PIR SENSITIVITY
The Pulse Count jumper setting provides control for normal or difficult operating environments. Automatic Pulse Count is
recommended for reliable operation in environments which may be subject to temperature fluctuations that might cause
Figure 4
Figure 5
Figure 6
Approximate Effective Detection Diameter*
PIR Height
8'(2.4m)
10'(3m)
12'(3.6m)
18'(5.5m)
Diameter
31' (9.3m)
38' (11.7m)
46' (9.34m)
70' (21m)
* See "Mounting Height"
false alarms. The Single Pulse Count mode is more sensitive to minor temperature variations, and should be used in sites where variant heat sources will not cause alarms (See
Figure 1.)
REGISTERING
Transmitters must be registered with the system receiver in order to be monitored and supervised. Each transmitter has a unique factory-programmed identification number.
Refer to the receiver installation instructions for details on registering a transmitter.
1. Remove the ES1265 cover as described in “Mounting the Detector.”
2. To register a transmitter: when prompted by the receiver to "Reset Transmitter", press the Reset button. (See Figure 1.) Replace the ES1265 cover. Follow instructions
to test the transmitter.
Note: The ES1265 retains programming data in non-vvolatile memory. It does not require re-programming after loss of power. Install a new battery and press the reset button
to re-initialize the transmitter and restore programming.
WALK TEST:
With the cover on the unit, quickly (less than ½ second) pass a magnet near the Walk Test Reed Switch (Figure 1-G). This activates a 1-minute walk test mode. Within this
period, the Test LED will light every time the PIR senses motion. The unit will not transmit alarm signals during this test period.
Note: The LED indicator lights only during 1-minute walk test period, and during transmission test.
TRANSMISSION TEST:
With the cover on the unit, hold a magnet near the Walk Test Reed Switch for at least 1 second. This activates a 1-minute transmission test mode. Within this period, the unit
will transmit alarm and restoral cycles at regular intervals for approximately one minute. The LED will light every time the unit transmits.
OPERATION:
The ES1265 transmitter signals an alarm condition when motion is detected by the sensor. Once an alarm condition is signaled, further alarms are suppressed until no motion
is sensed for a period of more than 90 seconds.
TECHNICAL SPECIFICATIONS:
Dimensions:
Weight:
Detection Method:
Operating Temperature:
Humidity:
Battery:
Typical Battery life:
Visible Light Protection:
Temperature Compensation:
Pulse count:
LED indicator:
Frequency
5.2" x 2.25" (131mm x 57mm)
6.52 oz. (185g)
4-element PIR
32°F to 120°F (0°C to 49°C)
10% to 90% non-condensing
Inovonics BAT604 (3.0V lithium Duracell DL123A)
Note: Battery is supervised
2 years in location with low to moderate activity*
Stable against halogen light 8 feet (2.4m) or reflected light
Yes
Selectable single pulse or multiple pulse
lights only during 1-minute walk test period and during transmission test.
User selectable for Europe, Australia, New Zealand, US and MF4232 receivers. See Figure 1.
* The battery life of a PIR transmitter is highly dependent on "traffic" in its coverage area. PIRs installed in high-traffic areas may experience reduced battery life.
CHANGING THE BATTERY
1. Carefully remove old battery.
2. Install new battery.
, IMPORTANT: Press reset button to re-iinitialize the transmitter.
Discard old battery in accordance to the local laws and practices. Inovonics Wireless does not take responsibility for batteries that are not discarded properly.
WARRANTY & DISCLAIMER
Inovonics Wireless Corporation ("Inovonics") warrants its products ("Product" or "Products") to conform to its own specifications and to be free of defects in materials and
workmanship under normal use for a period of twenty-four (24) months from the date of manufacture. Within the warranty period, Inovonics will repair or replace, at its
option, all or any part of the warranted Product. Inovonics will not be responsible for dismantling and/or reinstallation charges. To exercise the warranty, the User ("User",
"Installer" or "Consumer") must work directly through their authorized distributor who will be given a Return Material Authorization ("RMA") number by Inovonics. Details of
shipment will be arranged directly through the authorized distributor.
This warranty is void in cases of improper installation, misuse, failure to follow installation and operating instructions, alteration, accident or tampering, and repair by anyone
other than Inovonics.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express, or implied. There is no warranty by Inovonics
that Inovonics product will be merchantable or fit for any particular purpose, nor is there any other warranty, expressed or implied, except as such is expressly set forth
herein. In no event shall Inovonics be liable for an incidental, consequential, indirect, special or exemplary damages, including but not limited to loss of profit, revenue or
contract, loss of use, cost of down time, or interruption of business, nor any claim made by distributor's customers, or any other person or entity.
This warranty will not be modified or extended. Inovonics does not authorize any person to act on its behalf to modify or extend this warranty. This warranty will apply only
to Inovonics Products. All other products, accessories or attachments used in conjunction with Inovonics equipment, including batteries, will be covered solely by their own
warranty, if any. Inovonics will not be liable for any direct, incidental or consequential damage or loss whatsoever, caused by the malfunction of Product due to products,
accessories, or attachments of other manufacturers, including batteries, used in conjunction with Inovonics Products.
The User recognizes that a properly installed and maintained security system may only reduce the risk of events such as burglary, robbery, personal injury and fire. It does not
insure or guarantee that there will be no death, personal damage, and/or damage to property. Inovonics does not claim that the Product may not be compromised and/or
circumvented, or that the Product will prevent any death, personal and/or bodily injury, and/or damage to property resulting from burglary, robbery, fire or otherwise, or that
the Product will in all cases provide adequate warning or protection.
Inovonics shall have no liability for any death, injury, or damage, however incurred, based on a claim that Inovonics Products failed to function. However, if Inovonics is held
liable, directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, Inovonics' maximum liability will not in any
case exceed the purchase price of the Product. This will be the complete and exclusive remedy against Inovonics.
Warning: The User should follow all installation, operation, and maintenance instructions. The User is strongly advised to conduct Product and systems tests at
least once each week. Changes in environmental conditions, electric or electronic disruptions, and tampering, may cause the Product to not perform as expected.
Warning: Inovonics warrants its Product to the User. The User is responsible for exercising all due prudence and taking necessary precautions for the safety and
protection of lives and property wherever Inovonics Products are installed. Inovonics strongly advises the User to program Products to be supervised when used in
applications affecting life safety. Users are warned that unsupervised devices are subject to undetected failure due to malfunction, battery failure, tampering, or
changes in environment.
This product bears the CE mark and certification.
Please email support@inovonics.com to request the "Declaration of Conformity."
e-mail: sales@inovonics.com • www.inovonicswireless.com
© 2004 Inovonics Wireless Corporation
04098A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:7d402cf1-7ddd-45e0-b707-abe1dcbe0a09
Producer                        : Acrobat Distiller 6.0 (Windows)
Creator Tool                    : QuarkXPress(tm) 5.0
Modify Date                     : 2004:05:28 09:58:24-06:00
Create Date                     : 2004:05:28 09:58:24-06:00
Document ID                     : uuid:55c99d5b-b168-4603-a9e8-0341d4ac4b8f
Format                          : application/pdf
Title                           : 04098A_.qxd
Creator                         : roger
Author                          : roger
EXIF Metadata provided by EXIF.tools
FCC ID Filing: HCQ3B6ETICR65

Navigation menu