Inovonics Wireless 3B6OT9HPT Extended Range Universal Transmitter User Manual 06431B

Inovonics Wireless Corporation Extended Range Universal Transmitter 06431B

manual

Download: Inovonics Wireless 3B6OT9HPT Extended Range Universal Transmitter User Manual 06431B
Mirror Download [FCC.gov]Inovonics Wireless 3B6OT9HPT Extended Range Universal Transmitter User Manual 06431B
Document ID1882309
Application IDnhhPz7ZTJR499UT+SAgCIA==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize3.78kB (47290 bits)
Date Submitted2013-01-18 00:00:00
Date Available2013-01-18 00:00:00
Creation Date2013-01-17 12:43:41
Producing SoftwareAcrobat Distiller 9.2.0 (Windows)
Document Lastmod2013-01-17 12:59:36
Document Title06431B.fm
Document CreatorPScript5.dll Version 5.2.2
Document Author: bwhitmer

1.3 What’s In the Carton
•
•
•
•
One 3.0V lithium battery, Inovonics part number BAT604
Three drywall anchors
Three mounting screws
Two selection jumpers
EN1252 Extended Range Universal
Transmitter
2 Installation and Startup
Installation Instructions
2.1 Installation Notes
1 Overview
The EN1252 extended range universal transmitter provides five
times the power of standard Inovonics universal transmitters. To
support the increased power, the EN1252 can operate using an
external power source or the internal battery. The unit is
designed for use with any standard contact or sensor that
provides a contact closure – normally open or closed – and
includes connections for two alarm inputs as well as tamper and
reset.
Note: The EN1252 requires use of a serial receiver or network
coordinator, as well as an application designed to support
advanced functionality.
• These products are designed to be maintained by
professional security technicians
• Products are tested for indoor use
• All products should be manually tested weekly
2.2 Install the Battery
1. Pry the top lip of the mounting bracket up, and lift the bracket
off of the transmitter.
2. Use your thumb to depress the housing release tab on the
bottom of the transmitter; separate the housing.
3. Install the battery.
2.3 Connect Input Wiring
If you have any problems with this procedure, contact Inovonics
technical services:
• E-mail: support@inovonics.com
• Phone: (800) 782-2709; (303) 939-9336
The transmitter has a three-terminal contact block that can
connect inputs from one or two external contact loops. The
middle terminal is a ground, which is shared by both contact
loops. Input one can be configured for either a normally open or
a normally closed contact loop using the NO/NC selection pins;
input two is always normally closed.
4. Connect cabling to input one and/or input two, as desired.
1.2 EN1252 Internal Components
2.4 Select Input Type
1.1 Inovonics Contact Information
2.5 Enable/Disable Housing Tamper
The N/O-N/C selection pins allow the choice of a normally open
or normally closed state for the contact circuit wired to the input
one terminal. The terminal is shipped set for normally closed,
with no selection jumper on the N/O selections pins. If you need
the input one terminal set for normally closed, no action is
needed; skip to 2.5, “Enable/Disable Housing Tamper”.
5. Place a selection jumper on the selection pins to select
normally open.
The tamper disable selection pins allow the housing tamper to be
disabled. If you do not wish to disable the tamper, no action is
needed; skip to 2.6, “Register the EN1252”. If you wish to disable
the housing tamper:
6. Place a selection jumper on the tamper disable selection pins
to disable the housing tamper.
7. Press the reset button to complete configuration.
Figure 1 EN1252 internal components
A Reset button
B Tamper disable selection pins
C Input two terminal
D Ground terminal
E Input one terminal
F NO/NC selection pins
G Housing tamper button
1.17.13 06431B © Inovonics, 2013 - www.inovonics.com
Caution: When pressing the reset button, make sure you don’t
also touch any selection pins. Touching selection pins while
pressing the reset button can inadvertently set the EN1252 to an
undesired configuration.
2.6 Register the EN1252
Transmitters must be registered with the system in order to be
monitored and supervised. When supervised, the transmitter will
send a check-in message to the receiver. Transmitters will send
a check-in message every three minutes. Each transmitter has a
unique factory-programmed identification number.
Note: Refer to the receiver installation instructions for details
about registering a transmitter.
8. When prompted by the receiver to reset transmitter, press
the reset button.
9. Replace the cover.
Caution: The EN1252 should be tested after registration to
ensure operation. To test the EN1252, activate each of the
conditions and ensure an appropriate response.
2.7 Mount the EN1252
10. Mount the bracket on the wall with the screws provided so
that the catch is on the bottom.
11. Clip the transmitter onto the bracket. Hook the bottom catch
first, then press the top into place.
3 Specifications
Dimensions: 3.5x1.7x0.9”
Weight: 1.9 oz
Typical battery life: 1 – 2 years (This does not include current
drawn by external devices)
Internal battery type: 3.0V lithium battery, Inovonics part number
BAT604
RF output power: 24 dBm (250 milliwatts) equivalent isotropically
radiated power
Operating environment: Temperature: -4°F to 140°F using
internal battery (-40°F to 185°F using appropriate external power
source)
Humidity: Up to 90% (non-condensing)
Market: North America
EchoStream® frequency: 902-928 MHz, Frequency hopping
spread spectrum
Regulatory compliance: FCC, Industry Canada, RoHS
Note: Specifications and data are subject to change without
notice.
4 Television and Radio Interference
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
5 Compliance Information
This device complies with part 15 of the FCC Rules and Industry
Canada license-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the
device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le
fonctionnement.
5.1 Comment to the User
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
5.2 Compliance Notification
The integrator is responsible to ensure the final configuration is
in compliance with the applicable FCC and IC regulations. This
module is limited to battery powered operation only. Connection
to the AC power lines, either directly or through another device,
requires a separate approval from the modular approval
obtained by Inovonics. The integrator is instructed to verify
compliance with the applicable requirements for modular
transmitters. The integrator is responsible for properly labeling
the product containing the module. Product labels must be
permanently affixed on the exterior of the enclosure containing
the module. Labels must include a statement indicating the
product contains the module and the label must specify the FCC
and IC identification numbers:
Example 1: "Contains RF Module - FCC ID: HCQ3B6OT9HPT /
IC IDL 2309A-0T9HPT"
Example 2: "Contains FCC ID: HCQ3B6OT9HPT / IC IDL
2309A-0T9HPT"
1.17.13 06431B © Inovonics, 2013 - www.inovonics.com
Caution: To maintain compliance to FCC RF exposure
guidelines, install the module at least 20 centimeters (7.8inches)
from the body of the user or nearby persons. The module may
not be co-located with any other transmitters or antennas except
in accordance with FCC multi-transmitter procedures.
6 Warranty and Disclaimer
Inovonics, Inc. ("Inovonics") warrants its products ("Product" or
"Products") to conform to its own specifications and to be free of
defects in materials and workmanship under normal use for a
period of thirty-six (36) months from the date of manufacture.
Within the warranty period, Inovonics will repair or replace, at its
option, all or any part of the warranted Product. Inovonics will not
be responsible for dismantling and/or reinstallation charges. To
exercise the warranty, the User ("User", "Installer" or
"Consumer") must work directly through their authorized
distributor who will be given a Return Material Authorization
("RMA") Number by Inovonics. Details of shipment will be
arranged directly through the authorized distributor.
This warranty is void in cases of improper installation, misuse,
failure to follow installation and operating instructions, alteration,
accident or tampering, and repair by anyone other than
Inovonics.
This warranty is exclusive and expressly in lieu of all other
warranties, obligations or liabilities, whether written, oral,
express, or implied. There is no warranty by Inovonics that
Inovonics product will be merchantable or fit for any particular
purpose, nor is there any other warranty, expressed or implied,
except as such is expressly set forth herein. In no event shall
Inovonics be liable for an incidental, consequential, indirect,
special, or exemplary damages, including but not limited to loss
of profit, revenue or contract, loss of use, cost of down time, or
interruption of business, nor any claim made by distributor's
customers or any other person or entity.
This warranty will not be modified or extended. Inovonics does
not authorize any person to act on its behalf to modify or extend
this warranty. This warranty will apply only to Inovonics Products.
Inovonics will not be liable for any direct, incidental or
consequential damage or loss whatsoever, caused by the
malfunction of Product due to products, accessories, or
attachments of other manufacturers, including batteries, used in
conjunction with Inovonics Products.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : bwhitmer
Create Date                     : 2013:01:17 12:43:41-07:00
Modify Date                     : 2013:01:17 12:59:36-07:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2013:01:17 12:59:36-07:00
Producer                        : Acrobat Distiller 9.2.0 (Windows)
Format                          : application/pdf
Title                           : 06431B.fm
Creator                         : bwhitmer
Document ID                     : uuid:d8bccae5-4d71-493c-b95a-14d121ebf125
Instance ID                     : uuid:8b2feed8-6bb2-4e9e-866f-79c0b5d99ba1
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: HCQ3B6OT9HPT

Navigation menu