Inpeco Spa a Socio Unico CANBUSGW0271 Radio Frequency Identification Device for Sample Carriers User Manual Copia di 2 Security

Inpeco Spa a Socio Unico Radio Frequency Identification Device for Sample Carriers Copia di 2 Security

User Manual

APTIO - Operations Manual 2-1799.007.203.0— February 2011Section 2 SecuritySecurity1. General Security, Section 2-2a. Security Notes, Section 2-2Sb. Safety Labels, Section 2-32. Environmental and power specifications, Section 2-6a. Environmental conditions, Section 2-6b. Power requirements, Section 2-6c. Compressed Air Requirements, Section 2-6d. Manufacturer, Section 2-7e. Waste Disposal, Section 2-7f. Hazardous substances, Section 2-7g. Installation Specifications, Section 2-8h. Bar Code Reader Lasers, Section 2-8i. Moving Parts, Section 2-8j. Equipment Protection, Section 2-8k. FCC warning statements, Section 2-8
Security Section 22-2 APTIO - Operations Manual 799.007.203.0— February 2011General Security Personnel operating the automation must be proficient in its operation, maintenance, andprocedures. To ensure safety, follow basic precautions.Security NotesWarnings, cautions, and notes are included throughout this manual to emphasizeimportant instructions.WARNING: Defined as a physical, mechanical, or procedural condition that could result in moderate to serious personal injury.CAUTION: Defined as a condition that could result in minor injury or interfere with proper functioning of the Automation System.IMPORTANT: Defined as precautions which, if not followed, could cause a negative impact on system operations or assay results.NOTE: Defined as supplemental information that is relevant to the current subject matter.
APTIO - Operations Manual 2-3799.007.203.0— February 2011Section 2 SecuritySafety LabelsThe following labels are affixed to the Automation System to alert the operator to safetyconsiderations.Icon DescriptionThe operator should refer to the FlexLab 3.6Operations Manual before performing procedures onthe Automation System.Indicates the Automation System l was manufactured in the European Union in compliance with European regulations.Manufacturing location.Manufactured by Inpeco S.p.A. Segrate (MI) - Italy in Borgone di Susa Factory Plan.The Waste Electrical and Electronic Equipment (WEEE) indicates separate collections for electrical and electronic equipment. Dispose of electrical or electronic components in a separate container in accordance with local legislation.Rotate the knob to lock or unlock the coverIdentifies the In Vitro Diagnostic device.Identifies for the U.S. and Canada: An Nemko-CCL mark that means the product is certified for both U.S. and Canadian markets to applicable U.S. and Canadian standards.
Security Section 22-4 APTIO - Operations Manual 799.007.203.0— February 2011Table Section 2.1: LabelsIcon DescriptionIdentifies an area where operators can be exposed to moving parts. Be careful around these parts when performing diagnostics and maintenance operations with safety shield and covers removed.Identifies an activity that may present a safety-related hazard and advises the operator to consult the associated caution or warning instructions provided.Identifies an activity or area where operators may be exposed to potentially infectious material.Identifies an activity or area where the operator may be exposed to hot surfaces (> 70°C/158°F).Identifies an area containing cutting parts. Follow manufacturer instructions written in this guide when performing maintenance.Identifies the warn of electrical hazards. Identifies that hazardous voltage is present behind the protective cover.
APTIO - Operations Manual 2-5799.007.203.0— February 2011Section 2 SecurityAvoid eye exposure to laser light.Do not stare into beam.Warns against direct viewing of the beam or reflections from the beam.• Input Output Module, Centrifuge Module and Storage and Retrieval Module cover lids should be opened completely to engage the locking mechanism.• When closing the Input Output Module, Centrifuge Module and Storage and Retrieval Module safety shields, pull out the lock and lower the safety shield.Use caution when opening the Input Output Module, Centrifuge Module and Storage and Retrieval Module safety shields to ensure they are fully open. Do not place objects on the top surface.Table Section 2.1: LabelsIcon Description
Security Section 22-6 APTIO - Operations Manual 799.007.203.0— February 2011Environmental and power specificationsEnvironmental conditionsTable 2.2: Storage ConditionsPower requirementsCompressed Air RequirementsDescription ValueOperating altitude up to 2000 meters above sea levelOperating temperature range 16° to 30° COperating humidity Max 80% at 30°C Overvoltage Category IPollution Degree 2Description ValueNon Operating altitude up to 12,000 meters above sea levelNon Operating Humidity 5% to 90%Non Operating Temperature -20°C to +60°CDescription ValueMains Line Frequency 50/60 HzMains Line voltages fluctuation Up to ± 10 %• Mains Line Voltages depending on system configuration as follow:Single phase configuration with UPS 230 V ~  3680 VASingle phase configuration without UPS 230 V ~  9200 VAThree phases configuration without UPS 400 V 3N ~  27600Mains Line voltages fluctuations Up to ± 10 %Description SpecificationCompressed air must be clean Oil free and dryCompressed air pressure range 7 to 9 bar
APTIO - Operations Manual 2-7799.007.203.0— February 2011Section 2 SecurityManufacturerThis equipment is manufactured by Inpeco S.p.A. in Borgone di Susa factory plant. www.inpeco.comInpeco S.p.A Via G. Di Vittorio, 11 - Segrate (MI) - ITALY Phone +39 (02) 36681300 - Fax +39 (02) 36681399.Viale Europa, 14. Borgone di Susa (TO) - ITALY Phone +39 (02) 36681400 - Fax +39 (02) 36681499.Waste DisposalDispose of all waste produced during the workcell operation according to local, state,and country regulations.Treatment of waste electrical and electronic equipment.The product at the end of its useful life, should be disposed of following the rules fordisposing differentiated and can not be treated as a simple urban waste.The product should be disposed of at collection centers or dedicated shall be returnedto the dealer if you want to replace it with another equivalent new.Figure 2.1: Waste symbolIndicates that the product meets the requirements of the new guidelines introduced toprotect the environment (2002/95/EC, 2002/96/EC, 2003/108/EC) and must be disposedof properly at the end of his life cycle.Request information from local authorities about the areas devoted to waste disposal.Who does not dispose of the product by following the instructions in this sectionresponds according to current regulations.Hazardous substancesPrecaution should be taken handling tubes. Tube handling must be done using protectivegloves and protective goggles. Automation system operators should follow ClinicalLaboratory Safety (i.e: NCCLS document GP17-A2-Clinical Laboratory Safety; ApprovedGuideline-Second Edition).IMPORTANT: Do not allow bleach or soapy water to spill through the Automation cover, or set any bleach solution or soapy water containers on the Automation surface. This could lead to contamination of samples, possibly causing erroneous patient results.
Security Section 22-8 APTIO - Operations Manual 799.007.203.0— February 2011Installation SpecificationsThe  FlexLab 3.6 Automation system must be installed by a qualified Inpecorepresentative. System installation includes a complete checkout to ensure the equipment is fullyoperational.This equipment is intended only for internal use.Bar Code Reader LasersThe Automation system has one or more Bar Code Readers emitting laser beams. All barcode reader laser beams are protected by means of a metallic shield. There are no laserbeams that are accessible and visible to the operator. Laser beam metallic shields must beleft in place. Moving PartsDue to the necessity to insert the sample tube racks in the Automation system modules(i.e.: IOM, RIM, etc) there are moving parts that are unavoidably exposed during thenormal use. Automation system operators should be adequately warned and trained. Theresidual potential risk is mitigated by means of warning labels.Equipment ProtectionIf the equipment is used in manner not specified in this Operations Manual the protectionprovided by the equipment may be impaired.FCC warning statementsThis device complies with Part 15 of the FCC rules subject to the following twoconditions:1) This device may not cause harmful interference2) This device must accept all interference received, including interference that may causeundesired operation.The antenna CANBUS antenna wirings incorporated in this equipment has been modifiedto comply with the Part 15 of the FCC rules. Ferrite Fair Rite 046117645 Bin H4 has been added on transponder cables.

Navigation menu