Instant Care 2020TX1 Two Button Remote User Manual NS 8 Manual

Instant Care, Inc. Two Button Remote NS 8 Manual

user manual

Download: Instant Care 2020TX1 Two Button Remote User Manual NS 8 Manual
Mirror Download [FCC.gov]Instant Care 2020TX1 Two Button Remote User Manual NS 8 Manual
Document ID1176439
Application IDmmfyJkvg2WvwmcS/g7oEpQ==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize21.69kB (271091 bits)
Date Submitted2009-09-28 00:00:00
Date Available2009-09-28 00:00:00
Creation Date2009-08-28 17:15:48
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2009-09-22 14:59:06
Document TitleNS-8 Manual
Document CreatorAcrobat PDFMaker 6.0 for Word
Document Author: Shelly

Remote (IC2020TX)
10-AUG-200
Identifying the Parts
Emergency Button/LED (Red/Red)
–Press once to dial the Emergency line and send
an Emergency alarm report to the Monitoring
Station.
–Red Light ON: Signal transmitted
– Red Light FLASH: Signal trasmitted & Low
Battery
Nurse Button/LED (White/Blue)
–Press once on the Nurse Button to dial the Nurse line.
–Press & hold for 5 sec to activate/deactivate Panic
Alarm.
–Blue Light ON: Signal transmitted
–Blue Light FLASH: Signal trasmitted & Low Battery
Learning-in IC2020TX
Press either the Red or White button, a radio signal will be transmitted to the Control
Panel for learning. Please refer to the operation manual of your Control Panel.
Operation
To dial Emergency Line: Press once on the Emergency button (Red) to dial the
Emergency line and send an Emergency alarm report to the Monitoring Station. The
Red button will light up in Red.
To dial Nurse Line: Press once on the Nurse button (White) to dial the Nurse line.
The White button will light up in Blue after the button is released.
To activate/deactivate Panic Alarm: Panic Alarm can be triggered ONLY when Panic
Mode Enable is set as ON on the Control Panel by Command 52 (please refer to the
separate user manual of the Control Panel CTC-1039).
Press and hold the Nurse button (White) for 5 sec. The White button will light up
steadily in Blue for 1 sec after the button is released. The Control Panel will repeatedly
play “Beep Beep Beep Emergency” until Panic Alarm is deactivated. To deactivate
Panic Alarm, press and hold the Nurse button (White) for 5 sec again. The White
button will light up steadily in Blue for 1 sec after the button is released.
No reporting is made during Panic Alarm.
However, while in Panic Alarm, pressing either the Emergency button (Red) on the
Remote (IC2020TX) or on the Control Panel (CTC-1039) will still dial the Emergency
line and send an Emergency Report to the Central Monitoring Station.
Light Indicator
When the Red or White button is pressed, the respective light will light up steadily in
Red or Blue to indicate the IC2020TX has successfully sent out a signal to the Control
Panel.
When in Low Battery status, instead of light up steadily, the respective light will flash in
Red or Blue to signal the user that it is now in Low Battery status. It is recommended to
replace the battery immediately.
Battery
The power source is one CR2032 3V 230mAh Lithium battery with a life expectancy of 8
years or over.
IC2020TX is able to detect low battery status. When the battery voltage is low, and when
either the Red or White button is pressed, the buttons will flash in Red or Blue and a low
battery signal will be transmitted to the Control Panel along with regular transmissions for
the Control Panel to alert the user accordingly. In Low Battery status, the IC2020TX
operates up to 1 year assuming 2 activations on average per day.
Auto Low Battery Detection
The Remote features Low Battery detection.
Press and hold the Red button for 15 seconds to activate this function. The Red Light will
flash 3 times then light up steadily for 1 sec to confirm; a battery status code is transmitted
to the Control Panel.
The Remote will automatically transmit a battery status code to detect Low Battery status
every 24 hours. If the Control Panel has not received the battery status code, it will then
notify the user accordingly (depending on the Control Panel setting).
Once Low Battery status is detected, the Remote will automatically transmit a battery
status code to the Control Panel every 12 hours to notify the user accordingly (depending
on the Control Panel setting).

Once Auto Low Battery Detection function is activated, it cannot be deactivated later
in any circumstances.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
You are cautioned that changes or modifications not expressly approved by the party responsible for
compliance could void your authority to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract
Page Count                      : 2
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:df98031a-8ffe-483a-bc02-45eff19c8d56
Producer                        : Acrobat Distiller 6.0 (Windows)
Comments                        : Drafted 11/28/02
Company                         : climax
Source Modified                 : D:20090825065736
Headline                        : Night Switch @868 MHZ
Create Date                     : 2009:08:28 17:15:48+08:00
Creator Tool                    : Acrobat PDFMaker 6.0 for Word
Modify Date                     : 2009:09:22 14:59:06+08:00
Metadata Date                   : 2009:09:22 14:59:06+08:00
Document ID                     : uuid:5b5e7a91-e77c-49b7-b327-fa9784911e01
Version ID                      : 2
Format                          : application/pdf
Title                           : NS-8 Manual
Creator                         : Shelly
Description                     : Night Switch @868 MHZ
Subject                         : 
Tagged PDF                      : Yes
Author                          : Shelly
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XO82020TX1

Navigation menu