Intel® Server Board S875WP1-E
Product Guide
A Guide for Technically Qualified Assemblers of Intel® Identified
Subassemblies/Products

Order Number: C32693-002

Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions.
See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at
http:\\support.intel.com.

Disclaimer
Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied
warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility for any errors that may
appear in this document. Intel makes no commitment to update nor to keep current the information contained in this
document. No part of this document may be copied or reproduced in any form or by any means without prior written consent
of Intel. Intel may make changes to documentation and product descriptions at any time, without notice.
An Intel® product, when used in accordance with its associated documentation, is "Year 2000 Capable" when, upon
installation, it accurately stores, displays, processes, provides, and/or receives date data from, into, and between the
twentieth and twenty-first centuries, including leap year calculations, provided that all other technology used in combination
with said product properly exchanges date data with it.
Intel, and Pentium are the trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States
and other countries.
* Other names and brands may be claimed as the property of others.

Copyright © 2003 Intel Corporation.

ii

Contents
1 Server Board Features................................................................................... 9
Server Board Connector and Component Locations ............................................................ 11
Back Panel Connectors................................................................................................ 12
Front Panel Connectors ............................................................................................... 12
Processor .............................................................................................................................. 13
Memory ................................................................................................................................. 13
Intel 875P Chipset................................................................................................................. 14
Intel 82875P Memory Controller Hub (MCH) ............................................................... 14
Intel 82801EB I/O Controller Hub (ICH5-R) ................................................................. 15
Intel 82802AC Firmware Hub (FWH) ........................................................................... 15
Video ..................................................................................................................................... 15
AGP Connector ............................................................................................................ 16
ATA Rage XL Video Controller..................................................................................... 16
Video Modes.................................................................................................. 16
Video Memory Interface ................................................................................ 17
Super I/O............................................................................................................................... 17
Serial Port .................................................................................................................... 18
Parallel Port.................................................................................................................. 18
Floppy Drive Controller ................................................................................................ 18
Keyboard and Mouse Connectors................................................................................ 18
USB ..................................................................................................................................... 19
High-Speed USB 2.0 Support ...................................................................................... 19
Legacy USB Support.................................................................................................... 19
PCI I/O Subsystem................................................................................................................ 20
32-bit, 33-MHz PCI Subsystem .................................................................................... 20
Device IDs (IDSEL) ....................................................................................... 21
Data Storage ......................................................................................................................... 21
Serial ATA (SATA) ....................................................................................................... 21
IDE Interfaces .............................................................................................................. 22
SCSI Hard Drive Activity LED Connector ...................................................... 22
Network Interface Controller (NIC)........................................................................................ 23
NIC Connector and Status LEDs................................................................... 23
Power Management .............................................................................................................. 24
Software Support through ACPI ................................................................................... 24
Wake-up Devices and Events ....................................................................... 26
Hardware Support ........................................................................................................ 27
Power Connector........................................................................................... 28
Fan Connectors ............................................................................................. 28
Instantly Available PC Technology ................................................................ 29
Hardware Management and Monitoring................................................................................ 30
Chassis Intrusion and Detection .................................................................................. 30
Password Security ................................................................................................................ 31
Real-Time Clock, CMOS SRAM, and Battery ....................................................................... 32
Recovering the CMOS .......................................................................................................... 32

iii

BIOS ..................................................................................................................................... 33
PCI Auto Configuration................................................................................................. 33
IDE Auto Configuration................................................................................................. 33
BIOS Updates .............................................................................................................. 34
Language Support ......................................................................................... 34
Custom Splash Screen.................................................................................. 35
Recovering BIOS Data ................................................................................................. 35
Boot Options ................................................................................................................ 35
CD-ROM and Network Boot .......................................................................... 35
Booting Without Attached Devices ................................................................ 36
Fast Booting Systems with Intel® Rapid BIOS Boot .................................................... 36
Intel Rapid BIOS Boot ................................................................................... 36
System Management BIOS (SMBIOS) ........................................................................ 37

2 Server Board Installation and Upgrades.................................................... 39
Tools and Supplies Needed .................................................................................................. 39
Before You Begin .................................................................................................................. 39
Emissions Disclaimer ................................................................................................... 39
Warnings and Cautions......................................................................................................... 39
Installing the I/O Shield ......................................................................................................... 41
Installing Chassis Standoffs .................................................................................................. 42
Intel Server Chassis SC5200 ........................................................................ 42
®
Intel Server Chassis SC5250-E ................................................................... 43
Installing the Server Board.................................................................................................... 44
Placing the Server Board into the Chassis .................................................... 44
Attaching the Server Board ........................................................................... 44
Installing the Processor......................................................................................................... 45
Removing the Processor....................................................................................................... 48
Installing and Removing Memory.......................................................................................... 49
DIMM Installation Guidelines........................................................................................ 49
Installing DIMMs........................................................................................................... 50
Removing DIMMs......................................................................................................... 51
Installing and Removing an AGP Card ................................................................................. 51
Installing an AGP Card................................................................................................. 52
Removing the AGP Card.............................................................................................. 52
Connecting the IDE Cable..................................................................................................... 53
Connecting the Serial ATA Cable (Optional)......................................................................... 54
Connecting Internal Headers ................................................................................................ 55
Connecting the Front Panel Header............................................................................. 55
Connecting the USB 2.0 Header .................................................................................. 56
Connecting Hardware Control and Power Cables ................................................................ 57
Connecting Fans .......................................................................................................... 58
Chassis Intrusion.......................................................................................................... 58
Connecting Power Cables............................................................................................ 58
Setting the BIOS Configuration Jumper ................................................................................ 58
Clearing Passwords .............................................................................................................. 59
Replacing the Battery............................................................................................................ 60

iv

Intel Server Board S875WP1-E Product Guide

3

Configuration Software and Utilities ......................................................... 63

Updating the BIOS with the Intel® Flash Memory Update Utility .......................................... 63
Obtaining the BIOS Update File ................................................................................... 63
Recording the Current BIOS Settings .......................................................................... 64
Creating Bootable Media ............................................................................... 64
Creating a BIOS Update Media.................................................................................... 65
Updating the BIOS ....................................................................................................... 66
Recovering the BIOS ............................................................................................................ 67
Using the Setup Program...................................................................................................... 68
BIOS Setup Program Modes........................................................................................ 68
Maintenance Menu....................................................................................................... 69
Main Menu.................................................................................................................... 70
Advanced Menu ........................................................................................................... 71
PCI Configuration Submenu.......................................................................... 72
Boot Configuration Submenu ........................................................................ 73
Peripheral Configuration Submenu ............................................................... 74
Drive Configuration Submenu ....................................................................... 76
Floppy Configuration Submenu ..................................................................... 79
Event Log Configuration Submenu................................................................ 80
Video Configuration Submenu....................................................................... 81
USB Configuration Submenu ........................................................................ 82
Chipset Configuration Submenu.................................................................... 83
Fan Control Configuration Submenu ............................................................. 85
Hardware Monitoring Submenu..................................................................... 86
Remote Access Configuration Submenu....................................................... 87
Security Menu .............................................................................................................. 88
Power Menu ................................................................................................................. 89
ACPI Submenu.............................................................................................. 89
Boot Menu .................................................................................................................... 90
Boot Device Priority Submenu....................................................................... 91
Hard Disk Drives Submenu ........................................................................... 91
Removable Devices Submenu ...................................................................... 92
ATAPI CDROM Drives Submenu .................................................................. 92
Exit Menu ..................................................................................................................... 93

4 Solving BIOS Problems ............................................................................... 95
BIOS Beep Codes................................................................................................................. 95
BIOS Error Messages ........................................................................................................... 96

5 Getting Help .................................................................................................. 99
World Wide Web ................................................................................................................... 99
Telephone ............................................................................................................................. 99

6 Technical Reference .................................................................................. 101
Server Board Connectors.................................................................................................... 101
Baseboard Connectors .............................................................................................. 102
Power, Fan, Chassis Intrusion Connectors ................................................. 102
Add-In Board and Peripheral Interface Connectors..................................... 103

Contents

v

Server Board Resources..................................................................................................... 104
Memory Map .............................................................................................................. 104
DMA Channels ........................................................................................................... 104
I/O Map ..................................................................................................................... 105
Interrupts .................................................................................................................... 106

7 Regulatory and Integration Information................................................... 107
Product Regulatory Compliance ......................................................................................... 107
Product Safety Compliance........................................................................................ 107
Product EMC Compliance .......................................................................................... 107
Product Regulatory Compliance Markings ................................................................. 108
Electromagnetic Compatibility Notices................................................................................ 109
FCC (USA) ................................................................................................................. 109
INDUSTRY CANADA (ICES-003) .............................................................................. 110
Europe (CE Declaration of Conformity)...................................................................... 110
Taiwan Declaration of Conformity .............................................................................. 110
Korean RRL Compliance............................................................................................ 110
Australia / New Zealand ............................................................................................. 110
Installation Precautions ....................................................................................................... 111
Installation Requirements.................................................................................................... 111
Prevent Power Supply Overload ................................................................................ 111
Place Battery Marking ................................................................................................ 112
Use Only for Intended Applications ............................................................................ 112

vi

Intel Server Board S875WP1-E Product Guide

Figures
Figure 1. Server Board Components .......................................................................................... 11
Figure 2. Back Panel Connectors ............................................................................................... 12
Figure 3. Front Panel Connectors............................................................................................... 12
Figure 4. Location of the Standby Power Indicator LED CR7J1 ................................................. 29
Figure 5. Location of Clear CMOS Jumper................................................................................. 32
Figure 6. Installing the I/O Shield................................................................................................ 41
Figure 7. Installing Chassis Standoffs in the SC5200 Chassis ................................................... 42
Figure 8. Installing Chassis Standoffs in the SC5250-E Chassis ............................................... 43
Figure 9. Placing the Server Board into the Chassis .................................................................. 44
Figure 10. Attaching the Server Board........................................................................................ 45
Figure 11. Installing the Processor in the Processor Socket ...................................................... 45
Figure 12. Attaching the Heat Sink to the Processor .................................................................. 46
Figure 13. Attaching the Fan Heat Sink Clips to the Processor Socket...................................... 47
Figure 14. Attaching the Fan Heat Sink Clips to the Processor Socket...................................... 47
Figure 15. Connecting the Processor Fan Cable to the Processor Fan Connector.................... 48
Figure 16. DIMM Socket Locations............................................................................................. 50
Figure 17. Installing the AGP Card ............................................................................................. 52
Figure 18. Connecting the IDE Cable ......................................................................................... 53
Figure 19. Connecting the SATA Cable...................................................................................... 54
Figure 20. Location of Internal Headers...................................................................................... 55
Figure 21. Location of the Fan Headers and Power Connectors................................................ 57
Figure 22. BIOS Configuration Jumper Block Location .............................................................. 58
Figure 23. Removing the Battery ................................................................................................ 62
Figure 24. Power, Fan, and Chassis Intrusion Connectors....................................................... 102
Figure 25. Add-in Board and Peripheral Interface Connectors ................................................. 103

Tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
Table 10.
Table 11.
Table 12.
Table 13.
Table 14.
Table 15.
Table 16.
Table 17.
Table 18.
Table 19.
Table 20.

Contents

Server Board Features .................................................................................... 9
Supported Processors ................................................................................... 13
Video Modes.................................................................................................. 16
PCI Bus Characteristics................................................................................. 20
PCI Bus Configuration IDs............................................................................. 21
10/100 Ethernet LAN Connector LEDs.......................................................... 23
10/100/1000 Gigabit Ethernet LAN Connector LEDs .................................... 24
Effects of Pressing the Power Switch under ACPI ........................................ 25
Wake-up Devices and Events ....................................................................... 26
Fan Connector Function/Operation ............................................................... 28
Supervisor and User Password Functions .................................................... 31
Front Panel Header (J7J1) ............................................................................ 55
USB 2.0 Header (J7E1)................................................................................. 56
Jumper Settings for the BIOS Setup Program Modes (J8J2) ........................ 59
BIOS Setup Program Menu Bar .................................................................... 68
BIOS Setup Program Function Keys ............................................................. 69
Maintenance Menu ........................................................................................ 69
Main Menu..................................................................................................... 70
Advanced Menu............................................................................................. 71
PCI Configuration Submenu.......................................................................... 72

vii

Table 21.
Table 22.
Table 23.
Table 24.
Table 25.
Table 26.
Table 27.
Table 28.
Table 29.
Table 30.
Table 31.
Table 32.
Table 33.
Table 34.
Table 35.
Table 36.
Table 37.
Table 38.
Table 39.
Table 40.
Table 41.
Table 42.
Table 43.
Table 44.
Table 45.
Table 46.
Table 47.
Table 48.

viii

Boot Configuration Submenu ........................................................................ 73
Peripheral Configuration Submenu ............................................................... 74
Drive Configuration Submenu ....................................................................... 76
Primary/Secondary/SATA-0/SATA-1 Master/Slave Submenus..................... 78
Floppy Configuration Submenu ..................................................................... 79
Event Log Configuration Submenu................................................................ 80
Video Configuration Submenu....................................................................... 81
USB Configuration Submenu ........................................................................ 82
Chipset Configuration Submenu.................................................................... 83
Fan Control Configuration Submenu ............................................................. 85
Hardware Monitoring Submenu..................................................................... 86
Remote Access Configuration Submenu....................................................... 87
Security Menu................................................................................................ 88
Power Menu .................................................................................................. 89
ACPI Submenu.............................................................................................. 89
Boot Menu ..................................................................................................... 90
Boot Device Priority Submenu....................................................................... 91
Hard Disk Drives Submenu ........................................................................... 91
Removable Devices Submenu ...................................................................... 92
ATAPI CDROM Drives Submenu .................................................................. 92
Exit Menu....................................................................................................... 93
Beep Codes................................................................................................... 95
BIOS Error Messages.................................................................................... 96
System Memory Map................................................................................... 104
DMA Channels ............................................................................................ 104
I/O Map........................................................................................................ 105
Interrupts ..................................................................................................... 106
Product Certification Markings..................................................................... 108

Intel Server Board S875WP1-E Product Guide

1 Server Board Features
This chapter briefly describes the main features of Intel® Server Board S875WP1-E. This server
board is available in two options:
• The server board S875WP1 includes dual-channel Serial ATA support with two Serial ATA
connectors. Support for RAID 0 and 1 support is planned.
• The server board S875WP1LX includes an additional four-port Serial ATA controller to
support a total of six Serial ATA connectors with support for RAID 0, 1, and 10.
Table 1 summarizes the major features of the desktop board.
Table 1.

Server Board Features

Feature

Description

Processors

Support for an Intel® Pentium® 4 processor in an mPGA478 package with an
800/533/400 MHz system bus

Memory

• Four 184-pin DDR SDRAM Dual Inline Memory Module (DIMM) sockets
• Support for up to 4 GB Unbuffered ECC system memory
• Support for single-sided or double-sided DIMMs (DDR266/333/400)

Chipset

Intel® 875P Chipset, consisting of:
• Intel® 82875P Memory Controller Hub (MCH)
• Intel® 82801EB I/O Controller Hub (ICH5-R) with support for up to six HighSpeed Universal Serial Bus 2.0 (USB 2.0) ports
• Intel® 82802AC 8 megabit Firmware Hub (FWH)

I/O Control

SMSC* LPC47M172 super I/O controller

Peripheral Interfaces

• Four external USB ports on the back panel with an additional internal header,
which provides support for an optional two USB ports for front panel support
(total possible six USB ports)
• One serial port and one serial header
• One parallel port
• Two IDE interfaces with ATA-66/100 support
• Two Serial ATA connectors (S875WP1) with support for RAID 0 and 1
planned or six Serial ATA connectors (S875WP1LX) with support for RAID 0,
1, and 10
• One floppy drive interface with support for one drive
• PS/2* keyboard and mouse ports

LAN

• One Intel® 82562ET 10/100 Fast Ethernet Controller
• One Intel® 82547EI Gigabit Ethernet Controller

Expansion Capabilities

One independent PCI bus (32-bit/33 MHz, 5 V) with three PCI connectors and
two embedded devices:
• 2D/3D graphics controller – ATI Rage* XL Video Controller with 8 MB of
SDRAM
• Serial ATA: SATA-150 controller, Promise Technology* PDC20319
• Accelerated Graphics Port (AGP) connector providing AGP 8x support
continued

9

Table 1.

Server Board Features (continued)

BIOS

Intel/AMI BIOS with support for:
• Advanced Configuration and Power Interface (ACPI)
• 8 megabit symmetrical flash memory
• Support for SMBIOS
• Intel® Rapid BIOS Boot
• Intel® Express BIOS Update

Power Management

Support for ACPI:
• Suspend to RAM (STR)
• Wake on USB, PCI, RS-232, PS/2, LAN, and front panel

Hardware Management

Hardware monitor with:
• Four fan sensing inputs used to monitor fan activity
• Remote diode temperature sensing
• Intel® Precision Cooling Technology fan speed control that automatically
adjusts chassis fan speeds based on system temperature
• Voltage sensing to detect out of range values

10

Intel Server Board S875WP1-E Product Guide

Server Board Connector and Component Locations
A

B

C

D

E

F

G

CC

H
BB
I
AA
J
K
Z

L

Y

M

X

N

W
V

O

P

U

S

T

A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.

System Fan 4 Header
+12V CPU Power Connector
Processor Socket
CPU Fan
DIMM Sockets
Main Power Connector
Floppy Drive Connector
Auxiliary Power Connector
Primary IDE Connector
Secondary IDE Connector
Serial B Header
System Fan 1 Header
System Fan 2 Header
Front Panel Connector
BIOS Configuration Jumper (J8J2)
SCSI LED Header
Hot Swap Backplane Header

R

Q

TP00182

R. Battery
S. SATA-A1 through SATA-A4 Connector
(S875WP1LX only, from left to right: SATA-A4,
SATA-A2, SATA-A3, SATA-A1)
T. Chassis Intrusion Header
U. PCI 32/33 Slots 1 – 3
(slots numbered from top to bottom)
V. System Fan 3 Header
W. Front Panel USB Header
X. Clear CMOS Jumper J8G1
Y. SATA-B1 and SATA-B2 Connectors
(slots numbered from left to right)
Z. AGP Connector
AA. NIC2 (10/100 Mb)
BB. NIC1 (1 Gb)
CC. Back Panel I/O Ports

Figure 1. Server Board Components

Server Board Features

11

Back Panel Connectors
The back panel connectors are color-coded in compliance with PC 99 recommendations.

C

F

G

A
B
D

E

H

I
TP00183

A.
B.
C.
D.
E.

PS/2 mouse
PS/2 keyboard
Parallel port
Serial port A
Video port

F.
G.
H.
I.

NIC 1 (1 Gb)
NIC 2 (10/100 Mb)
USB ports 1 and 2
USB ports 3 and 4

Figure 2. Back Panel Connectors

Front Panel Connectors
Figure 3 shows the location of the front panel connectors.

A

TP00184

B

A.
B.

SCSI LED Header
Front Panel Header

Figure 3. Front Panel Connectors

12

Processor
The S875WP1-E server board supports a single Intel Pentium 4 processor with an mPGA478
socket. The processor connects to the server board through the mPGA478 socket. The Intel
Pentium 4 processor can be removed and replaced to accommodate a supported higher speed
processor.
The server board S875WP1-E supports the following processors.
Table 2.

Supported Processors

Type

✏

Designation

System Bus

L2 Cache Size

Pentium 4 processor with Hyper- 2.40, 2.60, 2.80, and 3.0 GHz
threading (HT) Technology
3.06 GHz

800 MHz

512 KB

533 MHz

512 KB

Pentium 4 processor

2.0, 2.26, 2.4B, 2.53, 2.66, and
2.80 GHz

533 MHz

512 KB

2.0, 2.4 GHz

400 MHz

512 KB

NOTE
The processor is not included with the server board and must be purchased separately.

Memory
The S875WP1-E server board contains four 184-pin DIMM sockets and supports up to four DDR
SDRAM DIMMs. The minimum supported memory configuration is 128 MB and the maximum
configurable memory size is 4 GB with stacked unbuffered DDR266/333/400 ECC DIMMs.
Supported memory configurations are as follows:
• Up to four dual-channel 184-pin Double Data Rate (DDR) SDRAM DIMMs connectors with
gold-plated contacts. Supported memory configuration are:
 DDR400: to run DDR400 memory at full speed requires an Intel Pentium 4 processor
with 800 MHz front side bus (FSB) frequency.
 DDR333: to run DDR333 memory at full speed requires an Intel Pentium 4 processor
with 533 MHz FSB frequency. DDR333 memory will run at 320 MHz frequency when
using an Intel Pentium 4 processor with 800 MHz FSB frequency.
 DDR266: DDR266 memory may only be used with an Intel Pentium 4 processor with
400 MHz or 533 MHz FSB frequency only.
• Support for:
 Single-channel memory
 Unbuffered, single or double-sided DIMMs
 Serial Presence Detect (SPD) memory only
 Support for Suspend to RAM (STR), S3 ACPI state
 ECC and non-ECC RAM
 2.5 V memory

Server Board Features

13

•

Support for 128 Mb, 256 Mb, and 512 Mb memory technologies for the following memory
configurations:
 Up to 1.0 GB utilizing 128 Mb technology
 Up to 2.0 GB utilizing 256 Mb technology
 Up to 4.0 GB utilizing 512 Mb technology

Only DIMMs tested and qualified by Intel or a designated memory test vendor will be supported on
the S875WP1-E server board. Note that all DIMMs are supported by design, but only fully
qualified DIMMs will be supported. Mixed mode DDR DS-DIMMs (x8 and x16 on the same
DIMM) is not supported. Check the Intel Customer Support website for the latest tested memory
list:
http://support.intel.com/support/motherboards/server/S875WP1-E

Intel 875P Chipset
The Intel 875P chipset consists of the following devices:
• Intel 82875P Memory Controller Hub (MCH) with Accelerated Hub Architecture (AHA) bus
• Intel 82801EB I/O Controller Hub (ICH5) with AHA bus
• Intel 82802AC Firmware Hub (FWH)
The MCH is a centralized controller for the system bus, the memory bus, the AGP bus, and the
Accelerated Hub Architecture interface. The ICH5-R is a centralized controller for the board’s I/O
paths. The FWH provides the nonvolatile storage of the BIOS.

Intel 82875P Memory Controller Hub (MCH)
The MCH supports the data integrity features supported by the Pentium 4 processor bus, including
address, request, and response parity. The 875P chipset always generates ECC data while it is
driving the processor data bus, although the data bus ECC can be disabled or enabled by BIOS. It
is enabled by default. The MCH controls the Intel 82547EI from the CSA interface.
The MCH provides the following:
• An integrated DDR memory controller with auto detection.
• Support for ACPI Rev 2.0 compliant power management.
• AGP 2.0 slot, also known as AGP 8x

14

Intel Server Board S875WP1-E Product Guide

Intel 82801EB I/O Controller Hub (ICH5-R)
The Intel 82801EB ICH5-R has these features:
• Upstream Hub Interface to the MCH
• Integrated IDE controller (supports two Ultra ATA-100/66 mode, Ultra DMA 33 mode, and
PIO mode).
• Integrated SATA controller supports two SATA devices with transfer speeds up to 150 MB/s
and independent DMA operation on the two ports
• One USB 2.0-compliant host controller that supports all six USB ports
• SMBus 2.0 interface
• FWH interface
• Support for the Low Pin Count (LPC) interface.
• Integrated LAN controller (Intel 8562ET) for interfacing the ICH5-R LAN connect interface to
the LAN connect component
• 33 MHz Peripheral Component Interface (PCI) Local Bus slots supporting PCI
specification, Rev 2.3.
• Power management logic (ACPI Rev 2.0-compliant).
• Support for two Ultra DMA 33 / ATA 100/66 connectors.

Intel 82802AC Firmware Hub (FWH)
The Intel 82802AC Firmware Hub (FWH) includes an 8 megabit symmetrical flash memory
device. Internally, the device is grouped into eight 64 KB blocks that are individually erasable,
lockable, and unlockable.
The FWH provides the following:
• System BIOS program
• Logic that enables protection for storing and updating of platform information

Video
The server board S875WP1-E contains two separate, mutually exclusive graphics subsystems. You
can use either the AGP connector or the ATI Rage XL video controller. When an AGP card is
installed, the integrated 8 MB video controller is disabled.

Server Board Features

15

AGP Connector
AGP is a high-performance interface for graphics-intensive applications. AGP is independent of
the PCI bus and is intended for exclusive use with graphical display devices. The AGP bus follows
the AGP 3.0 specification.
The AGP connector on the server board S875WP1-E supports the following:
• 2X, 4X, or 8X AGP protocol
• 1.5 V add-in cards only
• Maximum bus bandwidth of 2.13 GB/sec

✏

NOTE
The AGP connector is keyed for 1.5 V AGP cards only. Do not attempt to
install a legacy 3.3 V AGP card. The AGP connector is not mechanically
compatible with legacy 3.3 V AGP cards.

ATA Rage XL Video Controller
The S875WP1-E server board provides an ATI Rage XL PCI graphics accelerator, along with
8 MB of video SDRAM and support circuitry for an embedded SVGA video subsystem. The ATI
Rage XL chip contains a SVGA video controller, clock generator, 2D and 3D engine, and
RAMDAC in a 272-pin PBGA. One 2Mx32 SDRAM chip provides 8 MB of video memory.
The SVGA subsystem supports a variety of modes, up to 1600 x 1200 resolution in 8/16/24/32 bpp
modes under 2D, and up to 1024 x 768 resolution in 8/16/24/32 bpp modes under 3D. It also
supports both CRT and LCD monitors up to 100 Hz vertical refresh rate.
The server board S875WP1-E provides a standard 15-pin VGA connector and supports disabling of
the on-board video through the BIOS Setup menu or when a plug-in video card is installed in the
AGP slot or any of the PCI slots.

Video Modes
The Rage XL chip supports all standard IBM* VGA modes. The following table shows the 2D/3D
modes supported for both CRT and LCD. The table specifies the minimum memory requirement
for various display resolution, refresh rates, and color depths.
Table 3.

Video Modes

2D Mode
640x480

Refresh Rate (Hz)
60, 72, 75, 90, 100

S875WP1-E 2D Video Mode Support
8 bpp
16 bpp
24 bpp
Supported
Supported
Supported

32 bpp
Supported

800x600

60, 70, 75, 90, 100

Supported

Supported

Supported

Supported

1024x768

60, 72, 75, 90, 100

Supported

Supported

Supported

Supported

1280x1024

43, 60

Supported

Supported

Supported

Supported

1280x1024

70, 72

Supported

–

Supported

Supported
continued

16

Intel Server Board S875WP1-E Product Guide

Table 3.

Video Modes (continued)

1600x1200

60, 66

Supported

Supported

Supported

Supported

1600x1200

76, 85

Supported

Supported

Supported

–

3D Mode
640x480

Refresh Rate (Hz)
60,72,75,90,100

S875WP1-E 3D Video Mode Support with Z Buffer Enabled
Supported
Supported
Supported
Supported

800x600

60,70,75,90,100

Supported

Supported

Supported

Supported

1024x768

60,72,75,90,100

Supported

Supported

Supported

Supported

1280x1024

43,60,70,72

Supported

Supported

–

–

1600x1200

60,66,76,85

Supported

–

–

–

Video Memory Interface
The memory controller subsystem of the Rage XL arbitrates requests from direct memory interface,
the VGA graphics controller, the drawing coprocessor, the display controller, the video scalar, and
hardware cursor. Requests are serviced in a manner that ensures display integrity and maximum
CPU/coprocessor drawing performance.
The server board S875WP1-E supports an 8 MB (512Kx32bitx4 Banks) SDRAM device for video
memory.

Super I/O
The SMSC LPC47M172 I/O Controller provides the following features:
• Low pin count (LPC) interface
• 3.3 V operation
• One serial port and one serial port header
• One parallel port with Extended Capabilities Port (ECP) and Enhanced Parallel Port (EPP)
support
• Serial IRQ interface compatible with serialized IRQ support for PCI systems
• PS/2-style mouse and keyboard interfaces
• Interface for one 1.2 MB, 1.44 MB, or 2.88 MB diskette drive
• Intelligent power management, including a programmable wake up event interface
• PCI power management support
The BIOS Setup program provides configuration options for the I/O controller.

Server Board Features

17

Serial Port
The server board S875WP1-E has one serial port connector and one serial port header. The serial
port A connector is located on the back panel. The serial ports’ NS16C550-compatible UART
supports data transfers at speeds up to 115.2 kb/s with BIOS support.
A DH10 10-pin serial header is available on the baseboard for an option Serial B port.

Parallel Port
The 25-pin D-Sub parallel port connector is located on the back panel. In the BIOS Setup program,
the parallel port can be set to the following modes:
• Output only (PC AT*-compatible mode)
• Bi-directional (PS/2 compatible)
• EPP
• ECP

Floppy Drive Controller
The I/O controller supports one diskette drive that is compatible with the 82077 diskette drive
controller and supports both PC-AT and PS/2 modes.

Keyboard and Mouse Connectors
PS/2 keyboard and mouse connectors are located on the back panel. The +5 V lines to these
connectors are protected with a PolySwitch* circuit that, like a self-healing fuse, reestablishes the
connection after an overcurrent condition is removed.

✏

NOTE
The keyboard is supported in the bottom PS/2 connector and the mouse is
supported in the top PS/2 connector. Power to the computer should be turned
off before a keyboard or mouse is connected or disconnected.
The keyboard controller contains the AMI keyboard and mouse controller code, provides the
keyboard and mouse control functions, and supports password protection for power-on/reset. A
power-on/reset password can be specified in the BIOS Setup program.

18

Intel Server Board S875WP1-E Product Guide

USB
High-Speed USB 2.0 Support

✏

NOTES
Use a shielded cable that meets the requirements for a full-speed USB
device. Computer systems that have an unshielded cable attached to a USB
port might not meet FCC Class B requirements, even if no device or a lowspeed USB device is attached to the cable.
USB devices are limited to USB 1.1 transfer rates prior to operating system
and driver initialization.
The server board supports up to six USB 2.0 ports via the ICH5. Four ports are routed to the back
panel. One header, supporting up to two ports, is routed to the front panel. USB 2.0 ports are
backward compatible with USB 1.1 devices. USB 1.1 devices will function normally at USB 1.1
speeds.
USB 2.0 support requires both an operating system and drivers that fully support USB 2.0 transfer
rates. Disabling High-Speed USB in BIOS reverts all USB 2.0 ports to USB 1.1 operation. This
may be required to accommodate operating systems that do not support USB 2.0.

Legacy USB Support
Legacy USB support allows USB devices such as keyboard, mice, and hubs to be used even when
the operating system’s USB drivers are not available. Legacy USB support is used to access the
BIOS Setup program, and to install an operating system that supports USB. By default, Legacy
USB support is set to Enabled.
Four of the USB ports are implemented with stacked back panel connectors; the other two are
accessible via the front panel USB header. The S875WP1-E server board fully supports UHCI and
uses UHCI-compatible software drivers.

✏

NOTE
Computer systems that have an unshielded cable attached to a USB port may not
meet FCC Class B requirements, even if no device is attached to the cable. Use
s shielded cable that meets the requirements for full-speed devices.

Server Board Features

19

Legacy USB support operates as follows:
1. When the user applies power to the computer, legacy support is disabled.
2. POST begins.
3. Legacy USB support is enabled by the BIOS allowing the user to use a USB keyboard to enter
and configure the BIOS Setup program and the maintenance menu.
4. POST completes.
5. The operating system loads. While the operating system is loading, USB keyboard and mice
are recognized and may be used to configure the operating system. (Keyboard and mice are not
recognized during this period if Legacy USB support is set to Disabled in the BIOS Setup
program.)
6. After the operating system loads the USB drivers, all legacy and non-legacy USB devices are
recognized by the operating system, and Legacy USB support from the BIOS is no longer used.
To install an operating system that supports USB, verify that Legacy USB support in the BIOS
Setup program is set to Enabled and follow the operating system’s installation instructions.

✏

NOTE
Legacy USB support is for keyboard, mice, and hubs only. Other USB
devices are not supported in legacy mode.

PCI I/O Subsystem
The primary I/O bus for the server board S875WP1-E is PCI, with one independent PCI bus. The
PCI bus complies with the PCI Local Bus Specification, Rev 2.3. The PCI bus is directed through
the Intel 82801EB I/O Controller Hub (ICH5-R). The table below lists the characteristics of the
PCI bus.
Table 4.
Voltage
5V

PCI Bus Characteristics
Width
32-bits

Speed
33 MHz

Type
Independent Bus

Comments
Supports full-length cards

32-bit, 33-MHz PCI Subsystem
All 32-bit, 33-MHz PCI I/O for the server board S875WP1-E is directed through the Intel 82801EB
I/O Controller Hub (ICH5-R). The PCI bus supports the following embedded devices and
connectors:
• 2D/3D Graphics Accelerator: ATI Rage XL Video Controller.
• Serial ATA-100 controller: Promise Technology PDC20319.
• Three PCI slots
Each of the embedded devices listed above, with exception to the Ultra DMA 33 / ATA 100/66
connectors, will be allocated a GPIO to disable the device.

20

Intel Server Board S875WP1-E Product Guide

Device IDs (IDSEL)
Each device under the PCI hub bridge has its IDSEL signal connected to one bit of AD[31:16],
which acts as a chip select on the PCI bus segment in configuration cycles. This determines a
unique PCI device ID value for use in configuration cycles. The following table shows each
IDSEL value for the PCI bus devices and the corresponding device description.
Table 5.

PCI Bus Configuration IDs

IDSEL Value
16

Device
PCI slot 1 (closest to AGP connector)

17

PCI slot 2 (middle slot)

18

PCI slot 3 (closest to left edge of board)

22

ATI Rage XL Video Controller

23

Promise Technology PDC20319 ATA-100 controller

Data Storage
Serial ATA (SATA)
The server board S875WP1-E supports Serial ATA devices using the ICH5-R controller. The
ICH-5 provides the following Serial ATA support:
• 150 MB/sec transfer rate
• Up to two SATA devices on the server board S875WP1-E. These are indicated by the
connectors labeled SATA-B1 and SATA-B2 on the server board.
• Support for RAID 0 (Striping) and 1 (Mirroring) is planned, but not currently available.
The server board S875WP1LX supports an additional four Serial ATA devices using the Promise
Technology PDC20319 host controller. These are indicated by the connectors labeled from left to
right on the server board: SATA-A4, SATA-A2, SATA-A3, and SATA-A1. The Promise
PDC20319 controller provides the following Serial ATA support:
• 150 MB/sec transfer rate
• Support for RAID 0 (Striping), 1 (Mirroring), and 10 (Mirroring and Striping).

✏

NOTES
Although the Promise Technology PDC20319 Serial ATA controller on this
product supports up to 150 MB/sec transfer rate, the PCI bus limits some
SATA devices are limited to a maximum of 133 MB/sec.
For instructions on installing and configuring Serial ATA RAID on the 4-port
Promise Controller that is available on the server board S875WP1LX, please see
http://support.intel.com/support/motherboards/server/s875wp1e/sata-install.htm

Server Board Features

21

IDE Interfaces
The ICH5-R IDE controller has two independent bus-mastering IDE interfaces that can be
independently enabled. The interface handles the exchange of information between the processor
and peripheral devices like hard disks and CD-ROM drives. The IDE interfaces supports:
• Up to four IDE devices (such as hard drives)
• ATAPI devices (such as CD-ROM drives)
• Laser servo (LS-120) drives
• PIO Mode devices
• Ultra DMA-33: DMA protocol on IDE bus supporting host and target throttling and transfer
rates of up to 33 MB/sec.
• ATA-100/66: DMA protocol on IDE bus supporting host and target throttling and transfer
rates of up to 100 MB/sec. The ATA-100/66 protocol is similar to Ultra DMA and is device
driver compatible.

✏

NOTE
ATA-100/66 is a faster timing and requires a specialized cable to reduce
reflections, noise, and inductive coupling.
The IDE interfaces also support ATAPI devices (such as CD-ROM drives) and ATA devices using
the transfer modes.
The BIOS supports Logical Block Addressing (LBA) and Extended Cylinder Head Sector (ECHS)
translation modes. The drive reports the transfer rate and translation mode to the BIOS.
The S875WP1-E server board supports Laser Servo (LS-120) diskette technology through the IDE
interfaces. An LS-120 drive can be configured as a boot device by setting the BIOS Setup
program’s Boot menu to one of the following:
• ARMD-FDD (ATAPI removable media device – floppy disk drive)
• ARMD-HDD (ATAPI removable media device – hard disk drive)

SCSI Hard Drive Activity LED Connector
The SCSI hard drive activity LED connector is a 1 x 2-pin connector that allows an add-in
SCSI controller to use the same LED as the onboard IDE controller. For proper operation, this
connector should be wired to the LED output of the add-in SCSI controller. The LED indicates
when data is being read from, or written to, both the add-in SCSI controller and the IDE controller.

22

Intel Server Board S875WP1-E Product Guide

Network Interface Controller (NIC)
The server board S875WP1-E supports two Network Interface Controllers (NICs), one that runs at
10/100Mb and is based on the Intel 82562ET NIC and the other that runs at one gigabit and is
based on the Intel 82547EI NIC. When looking at the rear of the chassis, the gigabit NIC is at the
left (closest to the video port) and the 10/100Mb NIC is at the right. You can disable either or both
NICs through BIOS Setup.
The 82562ET is controlled by the ICH5-R and supports the following features:
• Integrated IEEE 802.3 10Base-T and 100Base-TX compatible PHY
• IEEE 802.3u auto-negotiation support
• Full duplex support at both 10 Mbps and 100 Mbps operation
• Low power +3.3 V device with reduced power in unplugged mode and automatic detection of
unplugged mode
• 3-port LED support
The 82547EI is controlled by the CSA interface off of the MCH. It supports the following features:
• Basic 10/100/1000 Ethernet LAN connectivity
• Integrated Gigabit Ethernet Media Access Control (MAC) and physical layer (PHY)
• IEEE 802.3 10BASE-T/100BASE-TX/1000BASE-T compliant physical layer interface
• IEEE 802.3ab auto-negotiation support
• Low power (less than 350mW in active transmit mode)
• Reduced power in “unplugged mode” (less than 50mW)
• Automatic detection of “unplugged mode”
• Communication Streaming Architecture (CSA) port provides higher throughput and lower
latencies resulting in up to 30% higher bus throughput (up to wirespeed)
• Full device driver compatibility
• Programmable transit threshold
• Configuration EEPROM that contains the MAC address
• Teaming and Fail over support

NIC Connector and Status LEDs
Two LEDs are built into each RJ-45 LAN connector. For the 82562ET NIC, the yellow LED indicates
a link to the LAN and the green LED indicates the connection speed. Table 6 describes the LED states
when the board is powered up and the 82562ET 10/100 Ethernet LAN subsystem is operating.
Table 6.
LED Color

10/100 Ethernet LAN Connector LEDs
LED State

Green (left
LED)
Yellow
(right LED)

Server Board Features

Indicates

Off

10 Mbit/sec data rate is selected.

On

100 Mbit/sec data rate is selected.

Off

LAN link is not established.

On (steady state)

LAN link is established.

On (brighter and pulsing)

The computer is communicating with another computer on the LAN.

23

Table 7 describes the LED states when the board is powered up and the 82547EI 10/100/1000
Gigabit Ethernet LAN subsystem is operating.
Table 7.
LED Color
Green (left
LED)

Bi-color LED
(right LED)

10/100/1000 Gigabit Ethernet LAN Connector LEDs
LED State

Indicates

Off

LAN link is not established.

On (steady state)

LAN link is established.

On (brighter and
pulsing)

The computer is communicating with another computer on the LAN.

Off

10 Mbit/sec data rate is selected.

Green

100 Mbit/sec data rate is selected.

Yellow

1000 Mbit/sec data rate is selected.

Power Management
Power management is implemented at several levels, including:
• Software support through Advanced Configuration and Power Interface (ACPI)
• Hardware support:
— Suspend to RAM (Instantly Available PC technology)
— Power connectors
— Fan connectors
— Resume on Ring
— Wake from USB
— Wake from PS/2 keyboard/mouse
— PME# wakeup support

Software Support through ACPI
The Advance Configuration and Power Interface (ACPI)–aware operating system can place the
system into a state where the hard drives spin down, the system fans stop, and all processing is
halted. In this state, the power supply is still on and the processors still dissipate some power, so
the power supply fan and processor fans are still running.
Under ACPI, the operating system directs all system and device power state transitions. The
operating system puts devices in and out of low-power states based on user preferences and
knowledge of how devices are being used by applications. Devices that are not being used can be
turned off. The operating system uses information from applications and user settings to put the
system as a whole into a low-power state.

24

Intel Server Board S875WP1-E Product Guide

ACPI features include:
• Plug and Play (including bus and device enumeration)
• Power management control of individual devices, add-in boards (some add-in boards may
require an ACPI-aware driver), video displays, and hard disk drives
• Methods for achieving less than 15-watt system operation in the power-on/standby
sleeping state
• A soft-off feature that enables the operating system to power-off the computer
• Support for multiple wake-up events
• Support for a front panel power and sleep mode switch
The Server Board S875WP1-E supports sleep states S0, S1, S2, S3, S4, and S5. When the server
board is operating in ACPI mode, the operating system retains control of the system and the
operating system policy determines the entry methods and wake-up sources for each sleep state.
Sleep entry and wake-up event capabilities are provided by the hardware but are enabled by the
operating system. The following is a summary of the supported sleep states:
• S0: Normal running state.
• S1: Processor sleep state. No context will be lost in this state and the processor caches will
maintain coherency.
• S3: Suspend to RAM (Instantly Available PC Technology).
• S4: Hibernate or Save to Disk. The memory and machine state are saved to disk. Pressing the
power button or another wake-up event restores the system state from the disk and resumes
normal operation. This state assumes that no hardware changes were made to the system while
it was off.
• S5: Soft off. Only the RTC section of the chipset is running in this state.

CAUTION
The system is off only when the AC power is disconnected.
Table 8 lists the system states based on how long the power switch is pressed, depending on how
ACPI is configured with an ACPI-aware operating system.
Table 8.

Effects of Pressing the Power Switch under ACPI

If the system is in this state…

…and the power switch is
pressed for

Off
(ACPI S5 – Soft off)

Less than four seconds

On
(ACPI S0 – working state)

Less than four seconds

On
(ACPI S0 – working state)

More than four seconds

Sleep
(ACPI S1 – sleeping state)

Less than four seconds

Sleep
(ACPI S1 – sleeping state)

More than four seconds

Server Board Features

…the system enters this state
Power-on
(ACPI S0 – working state)
Soft-off/Standby
(ACPI S1 – sleeping state)
Fail safe power-off
(ACPI S5 – Soft off)
Wake-up
(ACPI S0 – working state)
Power-off
(ACPI S5 – Soft off)

25

Wake-up Devices and Events
CAUTION
For LAN wake capabilities, the 5 V standby line for the power supply must
be capable of providing adequate +5 V standby current. Failure to provide
adequate standby current when implementing LAN wake capabilities can
damage the power supply.
Table 9 provides an overview of the devices or events that can wake the computer from specific
states.
Table 9.

Wake-up Devices and Events

These devices/events can wake up the computer…

…from this state

Power button

S1, S3, S4 (Note 1), S5

RTC alarm

S1, S3, S4 (Note 1), S5

LAN

S1, S3, S4 (Note 1), S5

PCI via PME# signal

S1, S3, S4 (Note 1), S5

Resume on Ring (back panel Serial Port A)

S1, S3

USB

S1, S3

PS/2

S1, S3

Notes:
1.

✏

For LAN and PME#, S5 is disabled by default in the BIOS Setup program. Setting this option to Power On will
enable a wake-up event from LAN in the S5 state.

NOTE
The use of these wake-up events from an ACPI state requires an operating
system that provides full ACPI support. In addition, software, drivers, and
peripherals must fully support ACPI wake events.

LAN Wake
LAN wake capabilities enable remote wake-up of the computer through a network. The LAN
subsystem PCI bus network adapter monitors network traffic at the Media Independent Interface.
Upon detecting a Magic Packet* frame, the LAN subsystem asserts a wake-up signal that wakes up
the computer from ACPI S1, S3, S4, and S5 state.
Depending on the LAN implementation, the S875WP1-E server board supports LAN wake
capabilities with ACPI in the following ways:
• The PCI bus PME# signal for PCI 2.2 compliant LAN designs
• The onboard LAN subsystem
PCI via PME# Wake-up Support
When the PME# signal on the PCI bus is asserted, the computer wakes from an ACPI S1, S3, S4, or
S5 state (with Wake on PME enabled in BIOS).

26

Intel Server Board S875WP1-E Product Guide

Resume on Ring
Resume on Ring enables telephony devices to access the computer when it is in a power-managed
state. The operation of Resume on Ring wakes the system from the S1 or S3 sleep states when a
signal is sent to the serial port at the rear or the chassis or to an internally installed modem. Resume
on ring can be summarized as follows:
• Resumes operation from ACPI S1 or S3 states
• Requires only one call to access the computer
• Detects incoming call similarly for external and internal modems
• Requires modem interrupt be unmasked for correct operation
Wake from USB
USB bus activity wakes the computer from an ACPI S1 or S3 state.

✏

NOTE
Wake from USB requires the use of a USB peripheral that supports Wake
from USB.

Wake from PS/2 Devices
PS/2 device activity, such as moving a PS/2 mouse or pressing a key on a PS/2 keyboard, wakes the
computer from an ACPI S1 or S3 state.

Hardware Support
The S875WP1-E server board provides several power management hardware features, including:
• Power connector
• Fan connectors
• Instantly Available PC technology
Instantly Available PC technology and LAN Wake require power from the +5 V standby line. The
sections discussing these features describe the incremental standby power requirements.

CAUTION
Ensure that the power supply provides adequate +5 V standby current if
Instantly Available PC technology features is used. Failure to do so can
damage the power supply. The total amount of standby current required
depends on the wake devices supported and manufacturing options.

Server Board Features

27

Power Connector
When used with an ATX12V or EPS12V compliant power supply that supports remote power
on/off, the S875WP1-E server board can turn off the system power through software control.
When the system BIOS receives the correct command from the operating system, the BIOS turns
off power to the computer.
With soft-off enabled, if power to the computer is interrupted by a power outage or a disconnected
power cord, when power resumes, the computer returns to the power state it was in before power
was interrupted (on or off). The computer’s response can be set using the After Power Failure
feature in the BIOS Setup program’s Boot menu.

✏

NOTE
A standard ATX 20 pin power connector and standard ATX 12V 4-pin 2x2
connector can be used to power the S875WP1-E board. Plug the power
cables into the pin 1 end of their respective motherboard connectors, leaving
pins 21-24 unused on the main power connector and 5-8 unused on the 12V
connector.

Fan Connectors
Table 10 summarizes the function/operation of the fan connectors.
Table 10.

Fan Connector Function/Operation

Connector

Description

Processor fan (CPU
FAN)

• +12 V DC connection for a processor fan or active fan heat sink.
• Fan is on in the S0 or S1 state.
Fan is off when the system is off or in the S3, S4, or S5 state.
• Wired to a fan tachometer input of the Hardware Management ASIC.

Front and rear chassis
fans (FAN1, FAN2,
FAN3, and FAN4)

• +12 V DC connection for a system or chassis fan.
• Fan is on in the S0 or S1 state.
Fan is off when the system is off or in the S3, S4, or S5 state.
• Wired to a fan tachometer input of the Hardware Management ASIC (Fans 1, 2,
and 4 only).

28

Intel Server Board S875WP1-E Product Guide

Instantly Available PC Technology
CAUTION
For Instantly Available PC technology, the +5 V standby line for the power
supply must be capable of providing adequate +5 V standby current. Failure
to provide adequate standby current when implementing Instantly Available
PC technology can damage the power supply.
The S875WP1-E server board supports the PCI Bus Power Management Interface Specification.
An add-in board that supports this specification can participate in power management and can be
used to wake the computer.
The use of Instantly Available PC technology requires operating system support and PCI 2.2
compliant add-in cards and drivers.
The standby power indicator LED shows that power is still present even when the computer
appears to be off. Figure 4 shows the location of the standby power indicator LED.

CAUTION
If AC power has been switched off and the standby power indicator is still lit,
disconnect the power cord before installing or removing any devices
connected to the board. Failure to do so could damage the board and any
attached devices.

CR7J1

TP00185

Figure 4. Location of the Standby Power Indicator LED CR7J1

Server Board Features

29

Hardware Management and Monitoring
The Hardware Management features enable the board to be compatible with the Wired for
Management (WfM) specification. The board has several hardware management features,
including the following:
• Remote temperature sensing near the Vreg
• Power supply monitoring (+5 V, +3.3 V, 3.3 VSB, +1.5 V, and VCCP) to detect levels above
or below acceptable values
• Fan monitoring though four fan tachometer inputs. Monitoring can be implemented using
LANDesk* Client Manager or other third-party software.
• Chassis intrusion detection
The server board S875WP1-E has an integrated Hardware Management ASIC that is responsible
for hardware monitoring. Together, the Hardware Management ASIC and the LANDesk Client
Manager (LDCM) 6.3 software provide basic server hardware monitoring that alerts a system
administrator if a hardware problem occurs on an Intel Server Board S875WP1-E based system.
The LDCM software is for use with Windows 2000 Server and Windows 2000 Advanced Server
operating systems. Other operating systems, such as Red Hat* Linux* are not be monitored with
LDCM.
Intel LANDesk Client Manager software and user guides that provide more information on using
Intel LDCM software are available on the Intel Server Board S875WP1-E Resource CD and are
also available for download at:
http://www.support.intel.com/support/motherboards/server/S875WP1-E

Chassis Intrusion and Detection
The server board S875WP1-E supports a chassis security feature that detects the removal of the
chassis cover. For the chassis intrusion circuit to function, the chassis’ power supply must be
connected to AC power. The security feature uses a mechanical switch on the chassis that attaches
to the chassis intrusion connector. Chassis intrusion options can be configured through the BIOS
Setup screens.

✏

NOTE
Chassis intrusion detection may be implemented using LANDesk Client
Manager or third-party software.

30

Intel Server Board S875WP1-E Product Guide

Password Security
The BIOS includes security features that restrict whether the BIOS Setup program can be accessed
and who can boot the server. A supervisor password and a user password can be set for the Setup
menu and for booting the server, with the following restrictions:
• The supervisor password gives unrestricted access to view and change all Setup options. If
only the supervisor password is set, pressing  at the password prompt of Setup gives the
user restricted access to Setup.
• If both the supervisor and user passwords are set, you must enter either the supervisor password
or the user password to access Setup. Setup options are then available for viewing and
changing depending on whether the supervisor or user password was entered.
• Setting a user password restricts who can boot the server. The password prompt is displayed
before the server is booted. If only the supervisor password is set, the server boots without
asking for a password. If both passwords are set, you can enter either password to boot
the server.
Table 11.

Supervisor and User Password Functions

Supervisor
Password Set Mode

User Mode

Setup Options

Password to
Enter Setup

Password
During Boot

Neither

Can change all
options (Note)

Can change all None
options (Note)

None

None

Supervisor
only

Can change all
options

Can change a
limited number
of options

Supervisor

None

User only

N/A

Can change all Enter Password
options
Clear User Password

User

User

Supervisor
and user set

Can change all
options

Can change a
limited number
of options

Supervisor or
user

Supervisor or
user

Note:

Supervisor Password

Supervisor Password
Enter Password

If no password is set, any user can change all Setup options.

Server Board Features

31

Real-Time Clock, CMOS SRAM, and Battery
The real-time clock provides a time-of-day clock and a multi-century calendar with alarm features.
The real-time clock supports 256 bytes of battery-backed CMOS SRAM in two banks that are
reserved for BIOS use.
A coin-cell battery (CR2032) powers the real-time clock and CMOS memory. When the computer
is not plugged into a wall socket, the battery has an estimated life of three years. When the
computer is plugged in, the standby current from the power supply extends the life of the battery.
The clock is accurate to ± 13 minutes/year at 25 ºC with 3.3 VSB applied.
The time, date, and CMOS values can be specified in the BIOS Setup program. The CMOS values
can be returned to their defaults by using the BIOS Setup program.

✏

NOTE
If the battery and AC power fail, custom defaults, will be loaded into CMOS
RAM at power-on if they defaults have been previously saved.

Recovering the CMOS
In the unlikely event that the CMOS should be corrupt, it can be cleared by using a jumper setting
on the server board. To recover the CMOS and return the settings to the default value:
1. Power down the server and unplug all AC power cables.
2. Remove the cover from the chassis.
3. Move the jumper at jumper block J8G1 to cover pins 2 and three. For the location of jumper
block J8G1, see the figure below.

J8G1
1

2

3

TP00200

Figure 5. Location of Clear CMOS Jumper

32

Intel Server Board S875WP1-E Product Guide

4.
5.
6.
7.
8.
9.

Reattach the AC power cables and power on the server.
Power down the server and again remove all AC power cables.
Replace the jumper at jumper block J8G1 so that it covers pins 1 and 2.
Replace the chassis cover and re-attach the AC power cables.
Power on the server.
Reconfigure settings as necessary.

BIOS
The S875WP1-E server board uses an Intel/AMI BIOS that is stored in the Firmware Hub (FWH)
and can be updated using a disk-based program. The FWH contains the BIOS Setup program,
POST, the PCI auto-configuration utility, and Plug and Play support.
The S875WP1-E server board supports system BIOS shadowing, allowing the BIOS to execute
from 64-bit onboard write-protected system memory.
The BIOS displays a message during POST identifying the type of BIOS and a revision code. The
initial production BIOS is identified as WP87510A.86B.
When the S875WP1-E server board’s jumper is set to configuration mode and the server is
powered-up, the BIOS compares the processor version and the microcode version in the BIOS and
reports if the two match.

PCI Auto Configuration
The BIOS can automatically configure PCI devices. PCI devices may be onboard or add-in cards.
Auto configuration lets a user insert or remove PCI cards without having to configure the system.
When a user turns on the system after adding a PCI card, the BIOS automatically configures
interrupts, the I/O space, and other system resources. Any interrupts set to Available in Setup are
considered to be available for use by the add-in card. Auto configuration information is stored in
ESCD format.

IDE Auto Configuration
If you select Auto in the BIOS Setup program, the BIOS automatically sets up the two
IDE connectors with independent I/O channel support. The IDE interface supports hard drives up
to ATA-66/100 and recognizes any ATAPI compliant devices, including CD-ROM drives, tape
drives, and Ultra DMA drives.
The BIOS determines the capabilities of each drive and configures them to optimize capacity and
performance. To take advantage of the high capacities typically available today, hard drives are
automatically configured for Logical Block Addressing (LBA) and to PIO Mode 3 or 4, depending
on the capability of the drive. You can override the auto-configuration options by specifying
manual configuration in the BIOS Setup program.

Server Board Features

33

To use ATA-66/100 features the following items are required:
• An ATA-66/100 peripheral device
• An ATA-66/100 compatible cable
• ATA-66/100 operating system device drivers

✏

NOTE
ATA-66/100-compatible cables are backward-compatible with drives using slower
IDE transfer protocols. If an ATA-66/100 disk drive and a disk drive using any
other IDE transfer protocol are attached to the same cable, the maximum transfer
rate between the drives is reduced to that of the slowest device.

BIOS Updates
The BIOS can be updated with the Intel® Flash Memory Update Utility. This utility is available on
the Intel World Wide Web site. The Intel® Flash Memory Update Utility requires creation of a
boot diskette and manual rebooting of the system. With this utility, the BIOS can be updated from
a file on a 1.44 MB diskette (from a legacy diskette drive or an LS-120 diskette drive) or from a
CD-ROM disk.
This utility support the following BIOS maintenance functions:
• Verifies that the updated BIOS matches the target system to prevent accidentally installing an
incompatible BIOS.
• Updates both the BIOS boot block and the main BIOS. This process is fault tolerant to prevent
boot block corruption.
• Updates the BIOS boot block separately.
• Changes the language section of the BIOS.
• Updates replaceable BIOS modules, such as the video BIOS module.
• Inserts a custom splash screen.

✏

NOTE
Review the instructions distributed with the upgrade utility before attempting
a BIOS update.

Language Support
The BIOS Setup program and help messages are supported in two languages: US English and
Spanish. Additional languages may be flashed in if desired (German, Italian, and French available).
The default language of US English is used unless another language is selected in the BIOS Setup
program.

34

Intel Server Board S875WP1-E Product Guide

Custom Splash Screen
During POST, an Intel splash screen is displayed by default. This splash screen can be replaced
with a custom splash screen. A utility is available from Intel to assist with creating a custom splash
screen. The custom splash screen can be programmed into the flash memory using the BIOS
upgrade utility. Information about this capability is available on the Intel Support World Wide
Web site.

Recovering BIOS Data
Some types of failure can destroy the BIOS. For example, the data can be lost if a power outage
occurs while the BIOS is being updated in flash memory. The BIOS can be recovered from a
diskette using the BIOS recovery mode. When recovering the BIOS, be aware of the following:
• Because of the small amount of code available in the non-erasable boot block area, there is no
video support. The user can only monitor this procedure by listening to the speaker or looking
at the diskette drive LED.
• The recovery process may take several minutes; larger BIOS flash memory devices require
more time.
• Two beeps and the end of activity in the diskette drive indicate successful BIOS recovery.
• A series of continuous beeps indicates a failed BIOS recovery.
To create a BIOS recovery diskette, a bootable diskette must be created and the BIOS update files
copied to it. BIOS upgrades and the Intel Flash Memory Update Utility are available from Intel
Customer Support through the Intel World Wide Web site.

✏

NOTE
Even if the computer is configured to boot from an LS-120 diskette, the BIOS
recovery diskette must be a standard 1.44 MB diskette, not a 120 MB diskette.

Boot Options
In the BIOS Setup program, the user can choose to boot from a diskette drive, a hard drive, a
CD-ROM drive, or the network. The default setting is for the diskette drive to be the first boot
device, the hard drive second, and the ATAPI CD-ROM third. The fourth device is disabled.

CD-ROM and Network Boot
Booting from CD-ROM is supported in compliance with the El Torito bootable CD-ROM format
specification. Under the Boot menu in the BIOS Setup program, ATAPI CD-ROM is listed as a
boot device. Boot devices are defined in priority order. Accordingly, if there is not a bootable CD
in the CD-ROM drive, the system will attempt to boot from the next defined drive.
The network can be selected as a boot device. This selection allows booting from the on-board NIC
or a network add-in card with a remote boot ROM installed.

Server Board Features

35

Booting Without Attached Devices
For use in embedded applications, the BIOS has been designed so that after passing the POST, the
operating system loader is invoked even if the following devices are not present:
• Video adapter
• Keyboard
• Mouse

Fast Booting Systems with Intel® Rapid BIOS Boot
These factors affect system boot speed:
• Selecting and configuring peripherals properly
• Using an optimized BIOS, such as the Intel Rapid BIOS

Intel Rapid BIOS Boot
Using the following BIOS Setup program settings reduces the POST execution time. In the Boot Menu:
• Set the hard disk drive as the first boot device. As a result, the POST does not first seek a
diskette drive, which saves about one second from the POST execution time.
• Disable Quiet Boot, which eliminates display of the logo splash screen. This could save several
seconds of painting complex graphic images and changing video modes.
• Enabled Intel® Rapid BIOS Boot. This feature bypasses memory count and the search for a
diskette drive.

✏

NOTE
It is possible to optimize the boot process to the point where the system boots
so quickly that the Intel logo screen (or a custom logo splash screen) will not
be seen. Monitors and hard disk drives with minimum initialization times
can also contribute to a boot time that might be so fast that necessary logo
screens and POST messages cannot be seen.
This boot time may be so fast that some drives might be not be initialized at
all. If this condition should occur, it is possible to introduce a programmable
delay ranging from three to 30 seconds (using the Hard Disk Pre-Delay
feature of the Advanced Menu in the Drive Configuration Submenu of the
BIOS Setup program).

36

Intel Server Board S875WP1-E Product Guide

System Management BIOS (SMBIOS)
SMBIOS is a Server Management Interface (DMI) compliant method for managing computers in a
managed network.
The main component of SMBIOS is the Management Information Format (MIF) database, which
contains information about the computing system and its components. Using SMBIOS, a system
administrator can obtain the system types, capabilities, operational status, and installation dates for
system components. The MIF database defines the data and provides the method for accessing this
information. The BIOS enables applications such as third-party management software to use
SMBIOS.
The BIOS stores and reports the following SMBIOS information:
• BIOS data, such as the BIOS revision level
• Fixed-system data, such as peripherals, serial numbers, and asset tags
• Resource data, such as memory size, cache size, and processor speed
• Dynamic data, such as event detection and error logging
Non-Plug and Play operating systems, such as Windows NT*, require an additional interface for
obtaining the SMBIOS information. The BIOS supports an SMBIOS table interface for such
operating systems. Using this support, an SMBIOS service-level application running on a
non-Plug and Play operating system can obtain the SMBIOS information.

Server Board Features

37

2 Server Board Installation and Upgrades
Tools and Supplies Needed
•
•
•
•

Phillips* (cross head) screwdriver (#1 bit and #2 bit)
Jumper removal tool or needle nosed pliers
Pen or pencil
Antistatic wrist strap and conductive foam pad (recommended)

Before You Begin
Emissions Disclaimer
To ensure EMC compliance with your local regional rules and regulations, the final configuration
of your end system product may require additional EMC compliance testing. For more information
please contact your local Intel Representative.
See “Regulatory and Integration Information” on page 107 for product Safety and EMC regulatory
compliance information. This is an FCC Class A device. Integration of it into a Class B chassis
does not result in a Class B device.

Warnings and Cautions
These warnings and cautions apply throughout this chapter. Only a technically qualified person
should configure the server board.

WARNING
Hazardous conditions, devices & cables: Hazardous electrical
conditions may be present on power, telephone, and communication cables.
Turn off the server and disconnect the power cord, telecommunications
systems, networks, and modems attached to the server before opening it.
Otherwise, personal injury or equipment damage can result.

Server Board Installation and Upgrades

39

CAUTIONS
System power on/off: The power button DOES NOT turn off the system
AC power. To remove power from system, you must unplug the AC power
cord from the wall outlet. Make sure the AC power cord is unplugged before
you open the chassis, add, or remove any components.
Electrostatic discharge (ESD) & ESD protection: ESD can damage
disk drives, boards, and other parts. We recommend that you perform all
procedures in this chapter only at an ESD workstation. If one is not
available, provide some ESD protection by wearing an antistatic wrist strap
attached to chassis groundany unpainted metal surfaceon your server
when handling parts.
ESD and handling boards: Always handle boards carefully. They can
be extremely sensitive to ESD. Hold boards only by their edges. After
removing a board from its protective wrapper or from the server, place the
board component side up on a grounded, static free surface. Use a
conductive foam pad if available but not the board wrapper. Do not slide
board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased
conductor that slips over two jumper pins. Some jumpers have a small tab on
top that you can grip with your fingertips or with a pair of fine needle nosed
pliers. If your jumpers do not have such a tab, take care when using needle
nosed pliers to remove or install a jumper; grip the narrow sides of the
jumper with the pliers, never the wide sides. Gripping the wide sides can
damage the contacts inside the jumper, causing intermittent problems with
the function controlled by that jumper. Take care to grip, but not squeeze,
with the pliers or other tool you use to remove a jumper, or you may bend or
break the stake pins on the board.

40

Intel Server Board S875WP1-E Product Guide

Installing the I/O Shield
CAUTION
Systems based on the S875WP1-E server board need the I/O shield properly
installed to pass emissions (EMI) certification testing and to meet Class A
emissions compliance levels. Without the I/O shield, or with an improperly
installed I/O shield, the server system will not meet Class A regulatory
compliance requirements.
The boxed server board comes with an I/O shield for a general-purpose chassis. When installed in
the chassis, the shield blocks radio frequency transmissions, protects internal components from dust
and foreign objects, and promotes correct airflow within the chassis.
Install the I/O shield before installing the server board in the chassis. Place the shield inside the
chassis and press the shield into place so that it fits tightly and securely. If the shield does not fit,
obtain a proper-sized shield from the chassis supplier.

TP00186

Figure 6. Installing the I/O Shield

Server Board Installation and Upgrades

41

Installing Chassis Standoffs
If your chassis does not have standoffs placed as shown below, you must rearrange them so they
match the holes in the server board. Failure to properly rearrange the metal standoffs may cause the
server board to malfunction and may permanently damage it. Your chassis may be different from
the illustration.

Intel Server Chassis SC5200
The chassis comes with standoffs installed in positions 1, 4, 6, 20, 23, and 26. Install standoffs in
the bottom of the chassis at positions 7, 10, 13, 17, 18, and 19. Standoffs are included with your
chassis.

1

7

17

4

10

18

6

13

19

TP00187

Figure 7. Installing Chassis Standoffs in the SC5200 Chassis

42

Intel Server Board S875WP1-E Product Guide

Intel® Server Chassis SC5250-E
The Intel® Server Chassis SC5250-E comes with standoffs pre-installed in positions K, E, A, N, I,
and D. Install standoffs in the bottom of the chassis at positions L, 3, 1, M, H, and C. Standoffs are
included with your chassis.

K

L

M

E

3

H

A

1

C

TP00188

Figure 8. Installing Chassis Standoffs in the SC5250-E Chassis

Server Board Installation and Upgrades

43

Installing the Server Board
Placing the Server Board into the Chassis
When placing the board into the chassis, insert the rear I/O connector end first, carefully
positioning the board’s I/O connectors into the openings in the I/O shield on the back of the chassis.

TP00103

Figure 9. Placing the Server Board into the Chassis

Attaching the Server Board

✏

NOTES
You will need a Phillips (#2 bit) screwdriver.
Refer to Page 107 for regulatory requirements and installation instructions
and precautions.
The Intel® Server Chassis SC5200 and the Intel Server Chassis SC5250-E use
different screws to attach the server board to the chassis. Be sure to use the
appropriate screw for your chassis. See the diagram below for the correct
screw for each chassis.

WARNING
Only qualified technical personnel should attempt this procedure. Disconnect
the server from its power source before performing the procedures described
here. Failure to disconnect the power before you open the server can result in
personal injury or equipment damage.

44

Intel Server Board S875WP1-E Product Guide

Using the screws that came with your chassis, mount the board to the chassis at the 9 locations
shown in Figure 10.

SC5200

SC5250-E

TP00189

Figure 10. Attaching the Server Board

Installing the Processor
To install a processor, follow these instructions:
1. Observe the safety and ESD precautions at the beginning of this chapter.
2. Locate the processor socket and raise the socket handle completely (see Figure 11, B).
3. Aligning the pins of the processor with the socket, insert the processor into the socket
(see Figure 11, A and C).
4. Close the handle completely (see Figure 11, D).
D

B

C

A

OM14263

Figure 11. Installing the Processor in the Processor Socket

Server Board Installation and Upgrades

45

✏

NOTE
The bottom of the heat sink may have thermal interface material (TIM)
already applied. Be careful not to damage the thermal interface material.
5. If there is no thermal interface material on the bottom of the heat sink, use the enclosed syringe
and apply the thermal interface material to the top of the processor.
6. Place the fan heat sink on top of the processor.

TP00208

Figure 12. Attaching the Heat Sink to the Processor

46

Intel Server Board S875WP1-E Product Guide

7. Fully open the levers at the top of the heat sink, as shown by letter “A” in the figure below.
8. With the levers in their fully opened position, push down firmly to secure the retention
mechanism clips, represented by letter “B” in the figure below.

A

A

B

TP00209

Figure 13. Attaching the Fan Heat Sink Clips to the Processor Socket

9. Firmly push the levers closed. It may be necessary to exert pressure to close the levers. See
Figure 14.

TP00206

Figure 14. Attaching the Fan Heat Sink Clips to the Processor Socket

Server Board Installation and Upgrades

47

10. Connect the processor fan cable to the processor fan connector (see Figure 15).

TP00201

Figure 15. Connecting the Processor Fan Cable to the Processor Fan Connector

Removing the Processor
To remove the processor, follow these instructions:
1. Observe the safety and ESD precautions at the beginning of this chapter.
2. Disconnect the processor fan cable.
3. Open the levers on the heat sink.
4. Disengage the retention mechanism hooks at the bottom of the heat sink.
5. Lift the heat sink from the processor.
6. Lift the processor lever.
7. Remove the processor.

48

Intel Server Board S875WP1-E Product Guide

Installing and Removing Memory
The S875WP1-E server board contains four 184-pin DIMM sockets and supports up to four DDR
SDRAM DIMMs. The minimum supported memory configuration is 128 MB, using one DIMM in
DIMM socket 1A. The maximum configurable memory size is a 4 GB, using four 1 GB stacked
unbuffered DDR266/333/400 ECC DIMMs.
The silkscreen on the board for the DIMMs displays DIMM1A, DIMM2A, DIMM1B, and
DIMM2B, starting from the inside of the board. The DIMM1A is the socket closest to the
processor socket. One, two, or four DIMMs may be used at a time.
For dual-channel interleave, a minimum of two DIMMs must be installed and the DIMMs must be
populated as follows:
• DIMM1A and DIMM 1B: Populate these two sockets together first
• DIMM 2A and DIMM 2B: Populate these sockets in addition to DIMM 1A and DIMM 2A if
four DIMMs are to be used
When four DIMMs are installed, the system will use dual-channel interleave. For single-channel
memory, a single DIMM can be installed in socket DIMM 1A. For single-channel memory using
two DIMMs, populate the DIMM sockets in the following order:
• DIMM1A: Populate this socket if a single DIMM is to be installed
• DIMM2A: Populate this socket and the DIMM1A socket if two DIMMs are to be used
Check the Intel Customer Support website for the latest tested memory list:
http://support.intel.com/support/motherboards/server/S875WP1-E

DIMM Installation Guidelines
All memory components and DIMMs used with the server board S875WP1-E must comply with
the DDR specifications.

Server Board Installation and Upgrades

49

Installing DIMMs
To install DIMMs, follow these steps:
1. Observe the safety and ESD precautions at the beginning of this chapter.
2. Turn off all peripheral devices connected to the server. Turn off the server and disconnect the
AC power cord.
3. Remove the server’s cover and locate the DIMM sockets (see Figure 16).

3

3

1

1
2

TP00190

Figure 16. DIMM Socket Locations

4. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open
position.
5. Holding the DIMM by the edges, remove it from its anti-static package.
6. Position the DIMM above the socket. Align the two small notches in the bottom edge of the
DIMM with the keys in the socket (see inset in Figure 16).
7. Insert the bottom edge of the DIMM into the socket.
8. When the DIMM is inserted, push down on the top edge of the DIMM until the retaining clips
snap into place. Make sure the clips are firmly in place.
9. Replace the server’s cover and reconnect the AC power cord.

50

Intel Server Board S875WP1-E Product Guide

Removing DIMMs
To remove a DIMM, follow these steps:
1. Observe the safety and ESD precautions at the beginning of this chapter.
2. Turn off all peripheral devices connected to the server. Turn off the server.
3. Remove the AC power cord from the server.
4. Remove the server’s cover.
5. Gently spread the retaining clips at each end of the socket. The DIMM pops out of the socket.
6. Hold the DIMM by the edges, lift it away from the socket, and store it in an anti-static package.
7. Reinstall and reconnect any parts you removed or disconnected to reach the DIMM sockets.
8. Replace the server’s cover and reconnect the AC power cord.

Installing and Removing an AGP Card
CAUTION
When installing any AGP card in the server board, ensure that it is fully
seated in the AGP connector before you power on the system. If the card is
not fully seated in the AGP connector, an electrical short may result across
the AGP slot pins. Depending on the over-current protection of the power
supply, certain board components and/or traces may be damaged.

✏

NOTE
The AGP connector is keyed for 1.5 V AGP cards only. Do not attempt to
install a legacy 3.3 V AGP card. The AGP connector is not mechanically
compatible with legacy 3.3 V AGP cards.
The AGP connector supports 1.5 V 8X, 4X, and 2X AGP cards. The server board has an integrated
AGP card retention mechanism (RM).

Server Board Installation and Upgrades

51

Installing an AGP Card
Follow these instructions to install an AGP card:
1. Observe the precautions in "Before You Begin" on page 39.
2. Place the card in the AGP connector.
3. Press down on the card until it is fully seated in the AGP connector. A retention notch on the
card will snap into place around the retention pin on the lever that is marked “A” in the figure
below.
4. Secure the card’s metal bracket to the chassis back panel with a screw.

A
TP00191

Figure 17. Installing the AGP Card

Removing the AGP Card
Follow these instructions to remove the AGP card from the server board:
1. Observe the precautions in "Before You Begin" on page 39.
2. Remove the screw that secures the card’s metal bracket to the chassis back panel.
3. Pull back on the retention mechanism lever (marked “A” in the figure above to release the
retention pin from the notch in the card.
4. Pull straight up on the card to pull it from the socket.

52

Intel Server Board S875WP1-E Product Guide

Connecting the IDE Cable
The Intel® boxed server board package includes a 40-contact, 80-conductor IDE cable. This cable is
capable of connecting two drives to the server board. The cable supports Ultra ATA/100/66 and
Ultra ATA/100 transfer protocols and is backward-compatible with drives using slower IDE
transfer protocols.

✏

NOTE
ATA-66/100 cables are backward compatible with drives using slower IDE
transfer protocols. If an ATA-66/100 disk drive and a disk drive using any
other IDE transfer protocol are attached to the same cable, the maximum
transfer rate between the drives may be reduced to that of the slowest drive.
Do not connect an ATA device as a slave on the same IDE cable as an
ATAPI master device. For example, do not connect an ATA hard drive as a
slave to an ATAPI CD-ROM drive.
For the cable to function correctly:
• Attach the end of the cable that has a single connector (A) to the server board as shown in
Figure 18. The connector at this end of the cable is black and is labeled PRI IDE.
• Attach the end of the cable that has two closely spaced connectors (B) to the drive(s). The
connectors at this end of the cable are gray and black and are labeled P2 and P3.
• If connecting only one IDE drive, connect the drive to the gray connector (P3).

A

TP00192

B

Figure 18. Connecting the IDE Cable

Server Board Installation and Upgrades

53

Connecting the Serial ATA Cable (Optional)
The Intel server board S875WD1 includes two Serial ATA (SATA) cables and the server board
S875WD1LX includes three SATA cables. These 4-conductor cables support the Serial ATA
protocol. Each cable connects a single drive to the server board.
For correct cable function, either end of the cable can be connected to the SATA drive or to the
connector on the board (see Figure 19).
1. Observe the precautions in “Before You Begin” on page 39.
2. Attach either cable end to the connector (A) on the board.
3. Attach either cable end to the connector (B) on the drive.

A

B
TP00193

Figure 19. Connecting the SATA Cable

✏

NOTE
For instructions on installing and configuring Serial ATA RAID on the 4-port
Promise Controller that is available on the server board S875WP1LX, please see
http://support.intel.com/support/motherboards/server/s875wp1e/sata-install.htm

54

Intel Server Board S875WP1-E Product Guide

Connecting Internal Headers
Before connecting internal headers, observe the precautions in “Before You Begin” on page 39.
B
1 2

A

2

10

1

9

33 34

TP00194

A

Front Panel USB 2.0 Header

B

Front Panel Header

Figure 20. Location of Internal Headers

Connecting the Front Panel Header
Before connecting the front panel header, observe the precautions in “Before You Begin” on
page 39. Figure 20 (above) shows the location of the front panel header. Table 12 shows the pin
assignments for the front panel header.
Table 12.

Front Panel Header (J7J1)

Pin

Signal Name

Pin(s)

Function

1

Power LED Anode

2

5VSB

3

Key

4

Unused

5

GND

6

Unused

7

HDD Activity LED Anode

8

Unused

9

HDD Activity LED Cathode

10

Unused

11

Power Switch

12

NIC#1 Activity LED Anode

13

GND (Power Switch)

14

NIC#1 Activity LED Cathode

15

FP_RST*

16

I1C SDA

17

GND (Reset Switch)

18

I2C SDA
continued

Server Board Installation and Upgrades

55

Table 12.

Front Panel Header (J7J1) (continued)

19

ACPI Sleep Switch

20

Chassis Intrusion

21

GND (ACPI Sleep Switch

22

NIC#2 Activity LED Anode

23

Unused

24

NIC#2 Activity LED Cathode

25

Key

26

Key

27

Unused

28

Unused

29

Unused

30

Unused

31

Unused

32

Unused

33

Unused

34

Unused

Connecting the USB 2.0 Header
Before connecting the USB 2.0 header, observe the precautions in “Before You Begin” on page 39.
Figure 20 shows the location of the USB 2.0 header. Table 13 shows the pin assignments for the
front panel header.
Table 13.

USB 2.0 Header (J7E1)

Pin

Signal name

Pin

Signal name

1

USB_FNT1_PWR

2

USB_FNT1_PWR

3

USB_FRONT1_L*

4

USB_FRONT2_L*

5

USB_ FRONT1_L

6

USB_FRONT2_L

7

Ground

8

Ground

9

Key

10

USB_ OC_FNT_R1

Note: USB ports may be assigned as needed.

56

Intel Server Board S875WP1-E Product Guide

Connecting Hardware Control and Power Cables
Figure 21 shows the location of the hardware control (fans and chassis intrusion) headers and
power supply connectors.

J1B1

A

B

J1F1

12 V

C

D
I
E
J6J3

F
J6J2

H

J7B1

G
TP00195

J9A1

A.
B.
C.
D.
E.

System Fan 4 Header
CPU Fan
Main Power Connector
Auxiliary Power Connector
System Fan 1 Header

F.
G.
H.
I.

System Fan 2 Header
Chassis Intrusion Header
System Fan 3 Header
+12V CPU Power Connector

Figure 21. Location of the Fan Headers and Power Connectors

Server Board Installation and Upgrades

57

Connecting Fans
Connect the processor’s fan heatsink cable to the processor fan header on the board. Connect the
chassis fan cables to the board fan headers. See Figure 21 for fan header locations.

Chassis Intrusion
Connect the chassis intrusion cable from the chassis to the 1 x 2 header on the board.

Connecting Power Cables
CAUTION
Failure to use an ATX12V power supply, or not connecting the 12 V
processor core voltage power supply connector to the desktop board may
+result in damage to the desktop board and/or power supply.
Figure 21 shows the location of power connectors.
1. Observe the precautions in “Before You Begin” on page 39.
2. Connect the 12 V processor core voltage power supply cable to the 2x2 connector.
3. Connect the main power cable to the 2x10 connector.

Setting the BIOS Configuration Jumper
CAUTION
Always turn off the power and unplug the power cord from the server before
changing the jumper. Moving the jumper with the power on may result in
unreliable server operation.

J8J2
3
2
1

TP00196

Figure 22. BIOS Configuration Jumper Block Location

58

Intel Server Board S875WP1-E Product Guide

This three-pin jumper block, shown in Figure 22, enables all server board configurations to be done
in BIOS Setup. Table 14 shows the jumper settings for the Setup program modes.
Table 14.

Jumper Settings for the BIOS Setup Program Modes (J8J2)

Jumper Setting
1

3

1

3

1

3

Mode
Normal (default) (1-2)

Description
The BIOS uses the current configuration and passwords for
booting.

Configure (2-3)

After the Power-On Self-Test (POST) runs, the BIOS displays
the Maintenance Menu. Use this menu to clear passwords.

Recovery (None)

The BIOS recovers data from a recovery diskette in the event of
a failed BIOS update.

Clearing Passwords
This procedure assumes that the board is installed in the computer and the configuration jumper
block is set to normal mode.
1. Observe the precautions in “Before You Begin” on page 39.
2. Turn off all peripheral devices connected to the computer. Turn off the computer. Disconnect
the computer’s power cord from the AC power source (wall outlet or power adapter).
3. Remove the computer cover.
4. Find the configuration jumper block (see (figure to be indicated)).
5. Place the jumper on pins 2-3 as shown below.
1

3

6. Replace the cover, plug in the computer, turn on the computer, and allow it to boot.
7. The computer starts the Setup program. Setup displays the Maintenance menu.
8. Use the arrow keys to select Clear Passwords. Press  and Setup displays a pop-up
screen requesting that you confirm clearing the password. Select Yes and press .
Setup displays the maintenance menu again.
9. Press  to save the current values and exit Setup.
10. Turn off the computer. Disconnect the computer’s power cord from the AC power source.
11. Remove the computer cover.
12. To restore normal operation, place the jumper on pins 1-2 as shown below.
1

3

Replace the cover, plug in the computer, and turn on the computer.

Server Board Installation and Upgrades

59

Replacing the Battery
When your server is turned off, a lithium battery maintains the time-of-day clock and the keeps the
values in CMOS RAM. The location of the server board battery is shown in Figure 23 on page 62.
The battery should last about seven years whereupon it begins to lose voltage. When the voltage
drops below a certain level, the BIOS Setup program settings stored in CMOS RAM (for example,
the date and time) might not be accurate. Replace the battery with an equivalent one.

CAUTION
Refer to technically qualified persons only for replacement of battery.

CAUTION
Risk of explosion if the battery is replaced with an incorrect type. Batteries
should be recycled where possible. Disposal of used batteries must be in
accordance with local environmental regulations.

PRECAUTION
Risque d'explosion si la pile usagée est remplacée par une pile de type
incorrect. Les piles usagées doivent être recyclées dans la mesure du
possible. La mise au rebut des piles usagées doit respecter les
réglementations locales en vigueur en matière de protection de
l'environnement.
(French)

FORHOLDSREGEL
Eksplosionsfare, hvis batteriet erstattes med et batteri af en forkert type.
Batterier bør om muligt genbruges. Bortskaffelse af brugte batterier bør
foregå i overensstemmelse med gældende miljølovgivning.
(Danish)

OBS!
Det kan oppstå eksplosjonsfare hvis batteriet skiftes ut med feil type.
Batterier bør sendes til gjenvinning hvis det er mulig. Brukte batterier bør
kastes i henhold til gjeldende miljølovgivning.
(Norwegian)

VIKTIGT!
Risk för explosion om batteriet ersätts med felaktig batterityp. Batterier bör
om möjligt återvinnas. Batterier ska kasseras enligt de lokala
miljövårdsbestämmelserna.
(Swedish)

60

Intel Server Board S875WP1-E Product Guide

VARO
Räjähdysvaara, jos pariston tyyppi on väärä. Paristot on kierrätettävä, jos se
on mahdollista. Käytetyt paristot on hävitettävä paikallisten
ympäristömääräysten mukaisesti.
(Finnish)

VORSICHT
Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die
Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller
empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien
den Anweisungen des Herstellers entsprechend.
(German)

AVVERTIMENTO
Esiste il pericolo di un esplosione se la pila non viene sostituita in modo
corretto. Utilizzare solo pile uguali o di tipo equivalente a quelle consigliate
dal produttore. Per disfarsi delle pile usate, seguire le istruzioni del
produttore.
(Italian)

PRECAUCIÓN
Existe peligro de explosión si la pila no se cambia de forma adecuada. Utilice
solamente pilas iguales o del mismo tipo que las recomendadas por el
fabricante del equipo. Para deshacerse de las pilas usadas, siga igualmente las
instrucciones del fabricante.
(Spanish)

WAARSCHUWING
Er bestaat ontploffingsgevaar als de batterij wordt vervangen door een
onjuist type batterij. Batterijen moeten zoveel mogelijk worden gerecycled.
Houd u bij het weggooien van gebruikte batterijen aan de plaatselijke
milieuwetgeving.
(Dutch)

ATENÇÃO
Haverá risco de explosão se a bateria for substituída por um tipo de bateria
incorreto. As baterias devem ser recicladas nos locais apropriados. A
eliminação de baterias usadas deve ser feita de acordo com as
regulamentações ambientais da região.
(Brazilian Portuguese)

Server Board Installation and Upgrades

61

To replace the battery, follow these steps:
1. Observe the safety and ESD precautions at the beginning of this chapter.
2. Turn off all peripheral devices connected to the server. Disconnect the server’s power cord
from the AC power source (wall outlet or power adapter).
3. Remove the server cover.
4. Locate the battery on the board (see Figure 23).
5. With your fingertip or a flathead screwdriver, gently pull back the tab away from the battery.
Pull out the battery. Note the orientation of the “+”on the battery.
6. Install the new battery in the connector, orienting the “+” as shown in Figure 23.
7. Replace the server cover.

TP00197

Figure 23. Removing the Battery

62

Intel Server Board S875WP1-E Product Guide

3 Configuration Software and Utilities
This chapter tells you how to update the BIOS by with the Intel Flash Memory Update Utility, and
how to recover the BIOS if an update fails.

Updating the BIOS with the Intel® Flash Memory
Update Utility
With the Intel Flash Memory Update Utility you can update the system BIOS from a floppy disk or
other bootable media. The utility available from the Web provides a simple method for creating a
bootable flash memory update floppy that will automatically update your BIOS.
• Prepare for the update
• Update the BIOS
• Recover the BIOS if an update fails

Obtaining the BIOS Update File
You can update to a new version of the BIOS or change the language section of the BIOS by using
the BIOS update file. The BIOS update file is a compressed self-extracting archive that contains all
the files you need to update the BIOS. The BIOS update file contains:
• New BIOS files
• BIOS recovery files
• Intel Flash Memory Update Utility
You can obtain the BIOS update file through your server supplier or from the Intel World Wide
Web site:
http://support.intel.com/support/motherboards/server/

✏

NOTE
Review the instructions distributed with the update utility before attempting a
BIOS update.

Configuration Software and Utilities

63

Recording the Current BIOS Settings
1. Boot the server and press  when you see the message:
Press  Key if you want to run SETUP

✏

NOTE
Do not skip step 2. You will need these settings to configure your server at
the end of the upgrade procedure.
2. Write down the current settings in the BIOS Setup program.

Creating Bootable Media
You can create bootable media with a:
• CD writer
• Normal diskette drive or an LS-120 diskette drive
Creating a Bootable CD
The instructions below assume a bootable diskette is used. When using a CD writer to use a CD,
follow the instructions provided with your CD writer to make a bootable CD using floppy
emulation and bootable files.
Creating a Bootable Diskette

✏

NOTE
If your drive A is an LS-120 diskette drive, you must use a 1.44 MB diskette
as the bootable BIOS update diskette. The server is unable to recover a
BIOS from an LS-120 diskette.
To create a bootable diskette using a DOS system:
• Place an unformatted diskette in the diskette drive and format the diskette using the /s option.
Example: format a: /s
• Alternatively, place a formatted diskette in the diskette drive and use the sys command.
Example: sys a:
To create a bootable diskette using a non-DOS system:
1. Obtain the BIOS update file through your server supplier or from the Intel World Wide Web
site: http://support.intel.com/support/motherboards/server/
2. Copy the BIOS update file to a temporary directory on your hard disk.
3. Change to the temporary directory.
4. To extract the files, double click on the BIOS update file, for example, EABIOSxx.EXE.
5. One of the extracted files is MK_BOOTZ.EXE. Double click on this file to extract the
README.TXT file.
6. Follow the directions in the README.TXT file.

64

Intel Server Board S875WP1-E Product Guide

Creating a BIOS Update Media
1. Obtain the BIOS update file through your server supplier or from the Intel World Wide
Web site:
http://support.intel.com/support/motherboards/server/
2. Copy the BIOS update file to a temporary directory on your hard disk.
3. From the C:\ prompt, change to the temporary directory.
4. To extract the file, type the name of the BIOS upgrade file, for example, EABIOSxx.
5. Press . The extracted file contains the following files:
• LICENSE.TXT
• BIOINSTR.TXT
• BIOS.EXE
• MK_BOOTZ.EXE
6. Read the LICENSE.TXT file, which contains the software license agreement, and the
BIOINSTR.TXT file, which contains the instructions for the BIOS update.
7. Insert the bootable diskette into drive A.
8. Extract the BIOS.EXE file to the diskette. From the directory that contains the BIOS.EXE file
type:
BIOS A:
9. Press .
10. The diskette now holds the new BIOS files, the Intel Flash Update Utility, and the
recovery files.

Configuration Software and Utilities

65

Updating the BIOS
CAUTION
The AUTOEXEC.BAT file provided with the update files updates the BIOS
in two parts: first updating the boot block and displaying the Operation
completed successfully message and second, updating the BIOS core.
You will be asked to reboot the system when the update process is complete.
Do not interrupt the process or the system may not be capable of rebooting.
1. Boot the server with the bootable BIOS upgrade diskette in drive A. During system boot, the
AUTOEXEC.BAT file provided with the update files will automatically run the BIOS update
process.
The AUTOEXEC.BAT file updates the BIOS in two parts: first updating the boot block and
displaying the Operation completed successfully message and then updating the BIOS
core.
2. When the update process is complete, the monitor will display a message telling you to remove
the diskette and to reboot the system.
3. As the server boots, check the BIOS identifier (version number) to make sure the upgrade was
successful. If a logo appears, press  to view the POST messages.
4. Enter BIOS Setup program by pressing  when you see the message:
Press  to Run SETUP

5.
6.
7.
8.
9.
10.

66

For proper operation, load the BIOS Setup program defaults. To load the defaults, press .
To accept the defaults, press .
In Setup, enter the settings you wrote down before beginning the BIOS upgrade.
To save the settings, press .
To accept the settings, press .
Turn off the server and reboot.

Intel Server Board S875WP1-E Product Guide

Recovering the BIOS
It is unlikely that anything will interrupt the BIOS update, however, if an interruption occurs, the
BIOS could be damaged. The following steps explain how to recover the BIOS if an update fails.
The following procedure uses recovery mode for the Setup program. See page 58 for more
information on Setup modes.

✏

NOTE
Because of the small amount of code available in the boot block area, there is
no video support. You will not see anything on the screen during this
procedure. Monitor the procedure by listening to the speaker and looking at
the diskette drive LED.
1. Turn off the server, disconnect the server’s power cord, and disconnect all external peripherals.
2. Remove the server cover and locate the configuration jumper block (J8J2) (see Figure 22).
3. Remove the jumper from all pins as shown below to set recovery mode for Setup.
3

1

4. Insert the bootable BIOS update diskette into diskette drive A.
5. Replace the server cover, connect the power cord, turn on the server, and allow it to boot. The
recovery process will take a few minutes. Listen to the speaker and watch for drive A activity.
• Upon applying power, drive A will begin to show activity. In about a minute, two beeps are
heard and drive A activity ceases (temporarily) indicating the successful recovery of the
BIOS core. Drive A activity will begin again followed by two more beeps indicating the
successful recovery of the boot block. This sequence of events indicates that successful
BIOS recovery has taken place.
• A series of continuous beeps indicates that BIOS recovery has failed.
6. If recovery fails, return to step 1 and repeat the recovery process.
7. If recovery is successful, turn off the server, disconnect the power cord, and remove the server
cover.
8. On the jumper block (J8J2), reinstall the jumper back on pins 1-2 as shown below to set normal
mode for Setup.
3

1

9. Leave the update diskette in drive A, replace the server cover, and connect the server’s
power cord.
10. Turn on the server and continue with the BIOS update (see page 66).

Configuration Software and Utilities

67

Using the Setup Program
You can use the BIOS Setup program to change the configuration information and boot sequence
for the server. This chapter tells you how to access the BIOS Setup program and lists Setup
features, options, and default settings.

✏

NOTE
For reference purposes, you should write down the current Setup settings.
When you make changes to the settings, update this record.

BIOS Setup Program Modes
The BIOS Setup program has three modes of operation:
• Normal mode for normal operations
• Configure mode for clearing passwords (see Chapter 2 for instructions)
• Recovery mode for BIOS recovery
The BIOS Setup Program Operating mode is controlled by the setting of the configuration jumper
block. The jumper is set to normal mode at the factory. The Maintenance menu is not available
when Setup is used with the jumper in normal mode. The Maintenance menu is available only when
the BIOS configuration jumper covers pins two and three.
The BIOS Setup program can be used to view and change the BIOS settings for the server. The
BIOS Setup program is accessed by pressing the  key after the Power-On Self-Test (POST)
memory test begins and before the operating system boot begins. The menu bar is shown below.
Maintenance

Main

Advanced

Security

Table 15. BIOS Setup Program Menu Bar
Maintenance Main
Advanced Security
Clears
passwords and
Boot Integrity
Service (BIS)*
credentials. View
and change the
CPU frequency
ratio

View BIOS
versions,
processor
speed and
type,
memory and
memory
mode.
Set
language,
system date
and time.

Allocate
resources for
hardware
components
Configures
advanced
features
available
through the
chipset

Sets
passwords
and security
features

Power

Boot

Exit

Power

Boot

Exit

Configures
power
management
features

Selects boot
options and
power supply
controls

Saves or
discards
changes to
Setup
program
options

* For information about the BIS, refer to the Intel Web site at: http://developer.intel.com/design/security/index1.htm

68

Intel Server Board S875WP1-E Product Guide

Table 16 shows the function keys available for menu screens.
Table 16.

BIOS Setup Program Function Keys

BIOS Setup Program Function Key

Description

<←> or <→>

Selects a different menu screen.

<↑> or <↓>

Moves cursor up or down.



Moves cursor to the next field.



Executes command or selects the submenu.



Load the default configuration values for the current menu.



Save the current values and exits the BIOS Setup program.



Exits the menu.

Maintenance Menu
This menu is used to clear passwords and to access processor information. Setup only displays this
menu when the BIOS Configuration jumper is in the configure mode. See page 58 for information
about setting the configure mode. To access this menu, select Maintenance on the menu bar at the
top of the screen.
Maintenance

Table 17.

Main

Advanced

Security

Power

Boot

Exit

Maintenance Menu

Feature

Options

CPU Frequency

• 8 to 1 ratio (default)

Description

• 12 to 1 ratio through
39 to 1 ratio
Clear All Passwords

• Ok (default)

Clears the user and administrative passwords.

• Cancel
Clear BIS Credentials

• Ok (default)
• Cancel

Clears the Wired for Management Boot Integrity
Service (BIS) credentials.

CPU Stepping Signature

No options

Displays CPU’s Stepping Signature.

CPU Microcode Update
Revision

No options

Displays CPU’s Microcode Update Revision.

Configuration Software and Utilities

69

Main Menu
To access this menu, select Main on the menu bar at the top of the screen.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

Table 18 describes the Main Menu. This menu reports processor and memory information and is for
configuring the system date and system time.
Table 18.

Main Menu

Feature

✏

Options

Description

BIOS Version

No options

Displays the version of the BIOS.

Processor Type

No options

Displays processor type.

Processor Speed

No options

Displays processor speed.

System Bus Speed

No options

Displays the system bus speed.

System Memory Speed

No options

Displays the memory speed.

Cache RAM

No options

Displays the size of second-level cache.

Total Memory

No options

Displays the total amount of RAM.

Memory Mode

No options

Displays whether interleaved or single-channel memory
mode is in place.

DIMM Slot 1A
DIMM Slot 2A
DIMM Slot 1B
DIMM Slot 2B

No options

Displays the amount and type of DIMMs in the memory
banks.

Memory Configuration

• Non-ECC
• ECC

Allows the user to enable error reporting in the system and
all installed memory supported ECC. If non-ECC memory
is installed, BIOS will detect and change the setting to nonECC.

Language

• English (default)
• Español

Selects the current default language used by the BIOS
(Deutsch, Italiano, and Français available via .lng files).

System Time

• Hour, minute, and Set current time. Use the Tab key to navigate fields
second

System Date

• Day of week
Month/day/year

Set current date. Use the Tab key to navigate fields.

NOTE
Additional language support is available. For more information visit Intel’s support
web site at: www.support.intel.com/support/motherboards/server/S875WP1-E

70

Intel Server Board S875WP1-E Product Guide

Advanced Menu
To access this menu, select Advanced on the menu bar at the top of the screen.
Maintenance

Advanced

Main

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

Table 19 describes the Advanced Menu. This menu is used for setting advanced features that are
available through the chipset.
Table 19.

Advanced Menu

Feature

Options

Description

PCI Configuration

Select to display
submenu

Displays the PCI Configuration submenu.

Boot Configuration

Select to display
submenu

Displays the Boot Configuration submenu.

Peripheral Configuration

Select to display
submenu

Displays the Peripheral Configuration submenu.

Drive Configuration

Select to display
submenu

Displays the Drive Configuration submenu.

Floppy Configuration

Select to display
submenu

Displays the Floppy Configuration submenu.

Event Log Configuration

Select to display
submenu

Displays the Event Log Configuration submenu.

Video Configuration

Select to display
submenu

Displays the Video Configuration submenu

USB Configuration

Select to display
submenu

Displays the USB Configuration submenu

Chipset Configuration

Select to display
submenu

Displays the Chipset Configuration submenu

Fan Control Configuration

Select to display
submenu

Displays the Fan Control Configuration submenu

Hardware Monitoring

Select to display
submenu

Displays the Hardware Monitoring submenu.

Remote Access Configuration Select to display
submenu

Configuration Software and Utilities

Displays the Remote Access Configuration submenu.

71

PCI Configuration Submenu
To access this submenu, select Advanced on the menu bar, then PCI Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 20 is for configuring the IRQ priority of PCI slots individually.
Table 20.

PCI Configuration Submenu

Feature

Options

Description

PCI Slot 1 IRQ Priority

•
•
•
•
•

Auto (default)
5
9
10
11

Allows selection of IRQ priority.

PCI Slot 2 IRQ Priority

•
•
•
•
•

Auto (default)
5
9
10
11

Allows selection of IRQ priority.

•
•
•
•
•

Auto (default)
5
9
10
11

Allows selection of IRQ priority.

(Note 1)

PCI Slot 3 IRQ Priority
(Note 1)

Notes:
1. Additional interrupts may be available if certain on-board devices (such as the serial and parallel ports) are disabled.

72

Intel Server Board S875WP1-E Product Guide

Boot Configuration Submenu
To access this submenu, select Advanced on the menu bar, then Boot Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 21 is for setting Plug and Play (PnP) options, resetting
configuration data, and the power-on state of the Numlock key.
Table 21.

Boot Configuration Submenu

Feature

Options

Description

Plug and Play O/S

• No (default)

Specifies if manual configuration is desired.
No lets the BIOS configure all devices. This setting is
appropriate when using a Plug and Play operating system.
Yes lets the operating system configure Plug and Play
devices not required to boot the system. This option is
available for use during lab testing.

• Yes

Numlock

• Off
• On (default)

Configuration Software and Utilities

Specifies the power-on state of the Numlock feature on the
numeric keypad of the keyboard.

73

Peripheral Configuration Submenu
To access this submenu, select Advanced on the menu bar, then Peripheral Configuration.
Maintenance

Main

Advanced

Security
Power
PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

Boot

Exit

The submenu represented in Table 22 is used for configuring server peripherals.
Table 22.

Peripheral Configuration Submenu

Feature

Options

Description

Serial Port A

• Disabled
• Enabled
• Auto (default)

Configures serial port A.
Auto assigns the first free COM port, normally COM1, the address
3F8h, and the interrupt IRQ4.
An * (asterisk) displayed next to an address indicates a conflict
with another device.

Base I/O Address

•
•
•
•

3F8 (default)
2F8
3E8
2E8

This option is available only when Serial Port A is set to Enabled.
Specifies the base I/O address for serial port A.

Interrupt

• IRQ 3
• IRQ 4 (default)

This option is available only when Serial Port A is set to Enabled.
Specifies the interrupt for serial port A.

Serial Port B

• Disabled
• Enabled
• Auto (default)

Configures serial port B.
Auto assigns the first free COM port, normally COM 2, the address
3F8h, and the interrupt IRQ4.
An * (asterisk) displayed next to an address indicates a conflict
with another device.

Mode

• Normal
• IrDA SIR-A
• ASK_IR

This option is available to set Serial Port B Mode. This includes
Normal and Infared Modes.

Base I/O address

•
•
•
•

3F8
2F8 (default)
3E8
2E8

This option is displayed only if Serial Port B is set to Enabled.
Specifies the base I/O address for serial port B.

Interrupt

• IRQ 3 (default)
• IRQ 4

This option is displayed only if Serial Port B is set to Enabled
Specifies the interrupt for serial port B.
continued

74

Intel Server Board S875WP1-E Product Guide

Table 22.

Peripheral Configuration Submenu (continued)

Feature

Options

Description

Parallel Port

• Disabled

Configures the parallel port.

• Enabled

Auto assigns LPT1 the address 378h and the
interrupt IRQ7.

• Auto (default)

An * (asterisk) displayed next to an address indicates a
conflict with another device.
Mode

• Output Only
• Bi-directional
(default)

Selects the mode for the parallel port. Not available if the
parallel port is disabled.
Output Only operates in AT-compatible mode.

• EPP

Bi-directional operates in PS/2-compatible mode.

• ECP

EPP is Extended Parallel Port mode, a high-speed
bi-directional mode.
ECP is Enhanced Capabilities Port mode, a high-speed
bi-directional mode.

Base I/O Address

• 378 (default)
• 278

This feature is present only when Parallel Port is set to
Enabled
Specifies the base I/O address for the parallel port.

Interrupt

• IRQ 5
• IRQ 7 (default)

This feature is present only when Parallel Port is set to
Enabled
Specifies the interrupt for the parallel port.

DMA

• 1
• 3 (default)

This feature is present only when Parallel Port Mode is set
to ECP
Specifies the DMA channel.

10/100 NIC

• Disabled

Enables or disables the on-board LAN#1 device.

• Enabled
(default)
Gigabit NIC

• Disabled

Enables or disables the on-board LAN#2 device.

• Enabled
(default)
ATI Rage XL Video

• Disabled
• Enabled
(default)

Promise PDC20319
S150 TX4

• Disabled

Enables or disables the on-board ATI* Rage XL video
controller.
Enables or disables RAID support.

• Enabled
(default)

Configuration Software and Utilities

75

Drive Configuration Submenu
To access this submenu, select Advanced on the menu bar, then Drive Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The menu represented in Table 23 is used to configure drive options.
Table 23.

Drive Configuration Submenu

Feature

Options

Description

ATA / IDE
Configuration

• Disabled

Selects the mode for the integrated IDE controller. When
Legacy is selected, a maximum of 4 drives can be
installed. When Enhanced is selected, a maximum of 6
drives can be installed.

• Legacy
• Enhanced (default)

Legacy IDE Channels • PATA Pri Only
• PATA Sec Only

This option is available only when Legacy is selected as
the IDE Mode.

• PATA Pri and Sec
(default)
• P0 / P1 Only
• SATA P0 / P1, PATA
Sec
• SATA P0 / P1, PATA
Pri
PCI IDE Bus Master

• Enabled (default)
• Disabled
continued

76

Intel Server Board S875WP1-E Product Guide

Table 23.

Drive Configuration Submenu (continued)

Hard Disk Pre-Delay

• Disabled (default)

Specifies the hard disk drive pre-delay.

• 3 Seconds
• 6 Seconds
• 9 Seconds
• 12 Seconds
• 15 Seconds
• 21 Seconds
• 30 Seconds
Intel (R) RAID
Technology

• Disabled (default)

SATA Port -0

Select to display submenu

Reports type of connected SATA device. When selected,
displays SATA Port-0 submenu.

SATA Port -1

Select to display
sub-menu

Reports type of connected SATA device. When selected,
displays SATA Port-1 submenu.

• Enabled

PATA Primary Master Select to display
sub-menu

Reports type of connected IDE device. When selected,
displays the Primary IDE Master submenu.

PATA Primary Slave

Select to display
sub-menu

Reports type of connected IDE device. When selected,
displays the Primary IDE Slave submenu.

PATA Secondary
Master

Select to display
sub-menu

Reports type of connected IDE device. When selected,
displays the Secondary IDE Master submenu.

PATA Secondary
Slave

Select to display
sub-menu

Reports type of connected IDE device. When selected,
displays the Secondary IDE Slave submenu.

Configuration Software and Utilities

77

Primary/Secondary/SATA-0/SATA-1 Master/Slave Submenus
To access these submenus, select Advanced on the menu bar, then Drive Configuration, and then
the master or slave to be configured.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

There are four IDE submenus: primary master, primary slave, secondary master, and secondary
slave. Table 24 shows the format of the IDE submenus. For brevity, only one example is shown.
Table 24.

Primary/Secondary/SATA-0/SATA-1 Master/Slave Submenus

Feature

Options

Description

Drive Installed

No options

Displays the type of drive installed.

Type

• User
• Auto (default)

Specifies the drive configuration.
User allows capabilities to be changed.
Auto fills-in capabilities from the device.

Maximum Capacity

No options

Displays the capacity of the drive. (SATA only)

LBA / Large Mode

• Disabled
• Auto (default)

This option can be changed only if User is selected as
the type.

Block Mode

• Disabled
• Auto (default)

This option can be changed only if User is selected as
the type.

PIO Mode

•
•
•
•
•
•

Auto (default)
0
1
2
3
4

This option can be changed only if User is selected as
the type.

DMA Mode

•
•
•
•

Auto (default)
SWDMA 0, 1, or 2
MWDMA 0, 1, or 2
UDMA 0, 1, 2, 3, 4, 5

This option can be changed only if User is selected as
the type.
SWDMA = Single Word DMA
MWDMA = Multi Word DMA
UDMA = Ultra DMA
continued

78

Intel Server Board S875WP1-E Product Guide

Table 24.

Primary/Secondary/SATA-0/SATA-1 Master/Slave Submenus (continued)

Feature

Options

Description

S.M.A.R.T

• Auto (default)

This option can be changed only if User is selected as
the type. If Auto is selected, this option is not displayed.

• Disabled

Cable Detected (Note)

Note:

• Enabled

Enables or disables Self-monitoring, Analysis, and
Reporting Technology.

No options

Displays the type of cable connected to the IDE
interface: 40-conductor or 80-conductor
(for ATA-66/100 devices).

These configuration options appear only if an IDE device is installed.

Floppy Configuration Submenu
To access this menu, select Advanced on the menu bar, then Floppy Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 25 is used for configuring the diskette drive.
Table 25.

Floppy Configuration Submenu

Feature

Options

Description

Diskette Controller

• Disabled
• Enabled (default)

Disables or enables the integrated diskette
controller.

Floppy A

•
•
•
•
•
•
•

Diskette Write-Protect

Specifies the capacity and physical size of
Disabled
diskette drive A.
360 KB
5¼ inch
1.2 MB
5¼ inch
720 KB
3½ inch
1.44 MB
3½ inch (default)
2.88 MB
3½ inch
Disables or enables write-protect for the
Disabled (default)
diskette drive.
• Enabled

Configuration Software and Utilities

79

Event Log Configuration Submenu
To access this menu, select Advanced on the menu bar, then Event Log Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 26 is used to configure the event logging features.
Table 26.

Event Log Configuration Submenu

Feature

Options

Description

Event Log

No options

Indicates if there is space available in the event log.

View Event Log

[Enter]

Displays the event log.

Clear Event Log

• OK (default)

Clears the event log after rebooting.

• Cancel
Event Logging

• Disabled

Enables logging of events.

• Enabled (default)
ECC Event Logging

• Disabled

Enables logging of ECC events.

• Enabled (default)
Mark Events As Read

• OK (default)

Marks all events as read.

• Cancel

80

Intel Server Board S875WP1-E Product Guide

Video Configuration Submenu
To access this menu, select Advanced on the menu bar, then Video Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 27 is used to configure the video features.
Table 27.

Video Configuration Submenu

Feature

Options

Description

AGP Aperture Size

• 4MB

Sets the aperture size for the AGP video controller.

• 8MB
• 16MB
• 32MB
• 64MB (default)
• 128MB
• 256MB
Primary Video Adapter

• AGP (default)
• PCI

Configuration Software and Utilities

Allows selecting an AGP or PCI video controller as
the display device that will be active when the system
boots.

81

USB Configuration Submenu
To access this menu, select Advanced on the menu bar, then USB Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 28 is used to configure the USB features.
Table 28.

USB Configuration Submenu

Feature

Options

Description

High-Speed USB

• Enabled (default)
• Disabled

Enables or disables the USB 2.0 driver. Disable this
option if the driver is not available.

• Disabled

Allows the use of legacy USB accessories.

Legacy USB support

• Enabled (default)
USB 2.0 Legacy Support
USB Data Area
Relocation

82

• FullSpeed (default)

FullSpeed = 480 Mbps

• HiSpeed

HiSpeed = 12 Mbps

• Disabled (default)
• Enabled

Intel Server Board S875WP1-E Product Guide

Chipset Configuration Submenu
To access this menu, select Advanced on the menu bar, then Chipset Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 29 is used to configure the chipset features.
Table 29.

Chipset Configuration Submenu

Feature

Options

Description

ISA Enable Bit

• Disabled

This option is required by some IDE expansion
devices.

• Enabled (default)
PCI Latency Timer

• 32
• 64
• 96
• 128
• 160
• 192
• 224
• 248

continued

Configuration Software and Utilities

83

Table 29.

Chipset Configuration Submenu (continued)

Extended Configuration

• Default (default)
• User Defined

SDRAM Frequency

• Auto (default)
• 266
• 333
• 400

SDRAM Timing Control

• Auto (default)
• Manual –
Aggressive
• Manual – User
Defined

This option is available only if User Defined is
selected as the Extended Configuration option. It
allows the user to override the detected memory
frequency value.
This option is available only if User Defined is
selected as the Extended Configuration option.
Auto: Timings are programmed according to the
memory detected.
Manual – Aggressive: Selects the most aggressive
user-defined timings.
Manual – User Defined: Allows manual override of
detected SDRAM settings.

CPC Override

• Auto (default)
• Enable
• Disable

SDRAM RAS Act. To Pre.

No options

SDRAM CAS# Latency

No options

Command Per Clock. When enabled, it allows the
DRAM controller to attempt chip select assertions in
two consecutive common clocks.

SDRAM RAS# to CAS delay No options
SDRAM RAS# Precharge

84

No options

Intel Server Board S875WP1-E Product Guide

Fan Control Configuration Submenu
To access this menu, select Advanced on the menu bar, then Fan Control Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 30 is used to configure the fan control features.
Table 30.

Fan Control Configuration Submenu

Feature

Options

Fan Control

• Disabled

Description

• Enabled (default)
Lowest Fan Speed

• Slow (default)
• Off

This option is available only if Enabled is selected as
the Fan Control.
Slow: At low system temperatures, the fans will
continue to run at a slow speed.
Off: At low system temperatures, the fans will turn off.

Configuration Software and Utilities

85

Hardware Monitoring Submenu
To access this menu, select Advanced on the menu bar, then Hardware Monitoring.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 30 is used to view the hardware that is monitored. These
options can be viewed only, not changed.

86

Table 31.

Hardware Monitoring Submenu

Feature

Options

Description

Processor Zone
Temperature

No options

Displays processor zone temperature.

System Zone 1
Temperature

No options

Displays system zone 1 temperature.

System Zone 2
Temperature

No options

Displays system zone 2 temperature.

Processor Fan Speed

No options

Displays the speed at which the processor fan is
running.

VReg Fan Speed

No options

Displays the speed for the rear fan.

Front Fan Speed

No options

Displays the speed for the front fan.

+1.5Vin

No options

Displays voltage level.

Vccp

No options

Displays voltage level.

+3.3Vin

No options

Displays voltage level.

+5Vin

No options

Displays voltage level.

+12Vin

No options

Displays voltage level.

Intel Server Board S875WP1-E Product Guide

Remote Access Configuration Submenu
To access this menu, select Advanced on the menu bar, then Remote Access Configuration.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

PCI Configuration
Boot Configuration
Peripheral Configuration
Drive Configuration
Floppy Configuration
Event Log Configuration
Video Configuration
USB Configuration
Chipset Configuration
Fan Control Configuration
Hardware Monitoring
Remote Access Configuration

The submenu represented by Table 32 is used to configure the remote access features.
Table 32.

Remote Access Configuration Submenu

Feature

Options

Description

Remote Access

• Disabled (default)

Permits or denies the ability to remotely manage the
system.

• Enabled
Serial Port Number

• COM1 (default)
• COM2

This option is available only if Enabled is set for the
Remote Access option.
Specifies the serial port to use for console redirection.
In addition to selecting the port number in BIOS
setup, make sure the selected port is enabled for use.

Serial Port Mode

• 115200 8,n,1
• 57600 8,n,1 (default)

This option is available only if Enabled is set for the
Remote Access option.

• 19200 8,n,1

Specifies the modem parameters for the selected
Com port.

Terminal Type

• VT100

This option is available only if Enabled is set for the
Remote Access option.

Post Boot Support

• Disabled (default)

This option is available only if Enabled is set for the
Remote Access option.

• Enabled

Specifies whether redirection should remain active
after booting to DOS. When enabled, redirection
remains active. When disabled, redirection is disabled
upon booting to DOS.

Configuration Software and Utilities

87

Security Menu
To access this menu, select Security from the menu bar at the top of the screen.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

The menu represented by Table 33 is for setting passwords and security features.
Table 33.

Security Menu

If no password entered previously:
Feature

Options

Description

Supervisor Password Is

No options

Reports if there is a supervisor password set.

User Password Is

No options

Reports if there is a user password set.

Set Supervisor Password

Password can be up to seven
alphanumeric characters.

Specifies the supervisor password.

Set User Password

Password can be up to seven
alphanumeric characters.

Specifies the user password.

Clear User Password (Note 1) • Ok (default)

Clears the user password.

• No
User Access Level (Note 2)

• No Access
• View Only

Sets BIOS Setup Utility access rights for user
level.

• Limited

No Access: User cannot access BIOS Setup.

• Full (default)

View Only: User can view BIOS Setup, but
cannot make any changes.
Limited: User can make limited changes in
BIOS Setup.
Full: User can change any field in BIOS Setup,
except for the Supervisor Password.

Chassis Intrusion

• Disabled (default)
• Log
• Log, notify once

Determines whether the chassis will be
monitored for intrusions and how intrusion
logging should be handled.

• Log, notify till cleared
Notes:
1.
2.

88

This feature appears only if a user password has been set.
This feature appears only if both a user password and a supervisor password have been set.

Intel Server Board S875WP1-E Product Guide

Power Menu
To access this menu, select Power from the menu bar at the top of the screen.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

ACPI

The menu represented in Table 34 is for setting the power management features.
Table 34.

Power Menu

Feature

Options

Description

ACPI

No Options

When selected, displays the ACPI submenu.

After Power Failure • Stays Off

Specifies the mode of operation if an AC power loss occurs.

• Last State (default)

Power On restores power to the server.

• Power On

Stay Off keeps the power off until the power button is
pressed.
Last State restores the previous power state before power
loss occurred.

Wake on PCI PME

• Stay Off (default)
• Power On

Specifies how the computer responds to a PCI power
management event.

ACPI Submenu
To access this menu, select Power on the menu bar, then ACPI.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

ACPI

The submenu represented in Table 35 is for setting the ACPI features.
Table 35.

ACPI Submenu

Feature

Options

Description

ACPI Suspend State

• S1 State

Specifies the ACPI sleep state.

• S3 State (default)
Wake on LAN from S5

• Stay Off (default)
• Power On

Configuration Software and Utilities

In ACPI soft-off mode only, determines how the system
responds to a LAN wake-up event.

89

Boot Menu
To access this menu, select Boot from the menu bar at the top of the screen.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

The menu represented in Table 36 is used to set the boot features and the boot sequence.
Table 36.

Boot Menu

Feature

Options

Description

Silent Boot

• Disabled (default)

Disabled displays normal POST messages.

• Enabled

Enabled displays OEM graphic instead of POST
messages.

AddOn ROM Display
Mode

• Enabled (default)

Intel®

• Disabled

Rapid BIOS Boot

• Disabled
• Enabled (default)

Scan User Flash Area
PXE Boot to LAN

• Disabled

Enables the computer to boot without running certain
POST tests.

• Enabled (default)

Enables the BIOS to scan the flash memory for user binary
files that are executed at boot time.

• Disabled (default)

Enables PXE boot.

• Enabled
USB Boot

• Disabled

Enables the computer to boot from USB boot devices.

• Enabled (default)

90

Boot Device Priority

Select to display
submenu

Specifies the boot sequence from the available types of
boot devices.

Removable Devices

Select to display
submenu

Specifies the boot sequence from the available removable
devices.

ATAPI CD-ROM Drives

Select to display
submenu

Specifies the boot sequence from the available ATAPI
CD-ROM drives.

Intel Server Board S875WP1-E Product Guide

Boot Device Priority Submenu
To access this menu, select Boot on the menu bar, then Boot Devices Priority.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

Boot Device Priority
Hard Disk Drives
Removable Devices
ATAPI CDROM Drives

The submenu represented in Table 37 is for setting boot devices priority.
Table 37.

Boot Device Priority Submenu

Feature

Options

Description

st

• Removable Dev.

nd

2 Boot Device

• Hard Drive

Specifies the boot sequence from the available types of
boot devices. To specify boot sequence:

3rd Boot Device

• ATAPI CD-ROM

1.

Select the boot device with <↑> or <↓>.

• Intel® UNDI, PXE

2.

Press  to set the selection as the intended
boot device.

1 Boot Device

th

4 Boot Device (Note 1)

• Disabled

The default settings for the first through fourth boot
devices are, respectively:
• Removable Dev.
• Hard Drive
• ATAPI CD-ROM
• Intel UNDI, PXE-2.0

Hard Disk Drives Submenu
To access this menu, select Boot on the menu bar, then Hard Disk Drives.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

Boot Device Priority
Hard Disk Drives
Removable Devices
ATAPI CDROM Drives

The submenu represented in Table 38 is for setting hard disk drive priority.
Table 38.

Hard Disk Drives Submenu

Feature
st

1 Hard Disk Drive

(Note)

Options

Description

Dependent on installed
hard drives

Specifies the boot sequence from the available hard
disk drives. To specify boot sequence:
1. Select the boot device with <↑> or <↓>.
2. Press  to set the selection as the intended
boot device.

Note:

This boot device submenu appears only if at least one boot device of this type is installed. This list will display up
to twelve hard disk drives, the maximum number of hard disk drives supported by the BIOS.

Configuration Software and Utilities

91

Removable Devices Submenu
To access this menu, select Boot on the menu bar, then Removable Devices.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

Boot Device Priority
Hard Disk Drives
Removable Devices
ATAPI CDROM Drives

The submenu represented in Table 39 is for setting removable device priority.
Table 39.

Removable Devices Submenu

Feature
st

1 Removable Device
(Note)

Options

Description

Dependent on installed
removable devices

Specifies the boot sequence from the available
removable devices. To specify boot sequence:
1. Select the boot device with <↑> or <↓>.
2. Press  to set the selection as the intended
boot device.

Note:

This boot device submenu appears only if at least one boot device of this type is installed. This list will display up
to four removable devices, the maximum number of removable devices supported by the BIOS.

ATAPI CDROM Drives Submenu
To access this menu, select Boot on the menu bar, then ATAPI CDROM Drives.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

Boot Device Priority
Hard Disk Drives
Removable Devices
ATAPI CDROM Drives

The submenu represented in Table 40 is for setting ATAPI CDROM drive priority.
Table 40.

ATAPI CDROM Drives Submenu

Feature
st

1 ATAPI CDROM Drive
(Note)

Options

Description

Dependent on installed
ATAPI CDROM drives

Specifies the boot sequence from the available
ATAPI CDROM drives. To specify boot sequence:
1. Select the boot device with <↑> or <↓>.
2. Press  to set the selection as the intended
boot device.

Note: This boot device submenu appears only if at least one boot device of this type is installed. This list will display up to
four ATAPI CDROM drives, the maximum number of ATAPI CDROM drives supported by the BIOS.

92

Intel Server Board S875WP1-E Product Guide

Exit Menu
To access this menu, select Exit from the menu bar at the top of the screen.
Maintenance

Main

Advanced

Security

Power

Boot

Exit

The menu represented in Table 41 is for exiting the BIOS Setup program, saving changes, and
loading and saving defaults.
Table 41.

Exit Menu

Feature

Description

Exit Saving Changes

Exits and saves the changes in CMOS SRAM.

Exit Discarding Changes

Exits without saving any changes made in the BIOS Setup program.

Load Setup Defaults

Loads the factory default values for all the Setup options.

Load Custom Defaults

Loads the custom defaults for Setup options.

Save Custom Defaults

Saves the current values as custom defaults. Normally, the BIOS reads the Setup
values from flash memory. If this memory is corrupted, the BIOS reads the
custom defaults. If no custom defaults are set, the BIOS reads the factory
defaults.

Discard Changes

Discards changes without exiting Setup. The option values present when the
server was turned on are used.

Configuration Software and Utilities

93

4 Solving BIOS Problems
The board reports POST errors in two ways:
• By sounding a beep code
• By displaying an error message on the monitor

BIOS Beep Codes
The BIOS beep codes are listed in Table 42. The BIOS also issues a beep code (one long tone
followed by two short tones) during POST if the video configuration fails, or if an external
ROM module does not properly checksum to zero.
Table 42.

Beep Codes

Number of Beeps

Description

1

Refresh failure

2

Parity cannot be reset

3

First 64 Kb memory failure

4

Timer not operational

5

Processor failure (Reserved; not used)

6

8042 GateA20 cannot be toggled (memory failure or not present)

7

Exception interrupt error

8

Display memory R/W error

9

(Reserved; not used)

10

CMOS Shutdown register test error

11

Invalid BIOS (such as, POST module not found)

Solving BIOS Problems

95

BIOS Error Messages
When a recoverable error occurs during the POST, the BIOS displays an error message describing
the problem (see Table 43).
Table 43.

BIOS Error Messages

Error Message

Explanation

GA20 Error

An error occurred with Gate A20 when switching to protected mode
during the memory test.

Pri Master HDD Error
Pri Slave HDD Error
Sec Master HDD Error
Sec Slave HDD Error

Could not read sector from corresponding drive.

Pri Master Drive - ATAPI Incompatible
Pri Slave Drive - ATAPI Incompatible
Sec Master Drive - ATAPI Incompatible
Sec Slave Drive - ATAPI Incompatible

Corresponding drive is not an ATAPI device. Run Setup to make
sure device is selected correctly.

A: Drive Error

No response from diskette drive.

CMOS Battery Low

The battery may be losing power. Replace the battery soon.

CMOS Display Type Wrong

The display type is different than what has been stored in CMOS.
Check Setup to make sure type is correct.

CMOS Checksum Bad

The CMOS checksum is incorrect. CMOS memory may have been
corrupted. Run Setup to reset values.

CMOS Settings Wrong

CMOS values are not the same as the last boot. These values
have either been corrupted or the battery has failed.

CMOS Date/Time Not Set

The time and/or date values stored in CMOS are invalid. Run
Setup to set correct values.

DMA Error

Error during read/write test of DMA controller.

FDC Failure

Error occurred trying to access diskette drive controller.

HDC Failure

Error occurred trying to access hard disk controller.

Checking NVRAM.....

NVRAM is being checked to see if it is valid.

Update OK!

NVRAM was invalid and has been updated.

Updated Failed

NVRAM was invalid but was unable to be updated.

Keyboard Error

Error in the keyboard connection. Make sure keyboard is
connected properly.

KB/Interface Error

Keyboard interface test failed.
continued

96

Intel Server Board S875WP1-E Product Guide

Table 43.

BIOS Error Messages (continued)

Error Message

Explanation

Memory Size Decreased

Memory size has decreased since the last boot. If no memory was
removed, then memory may be bad.

Memory Size Increased

Memory size has increased since the last boot. If no memory was
added, there may be a problem with the system.

Memory Size Changed

Memory size has changed since the last boot. If no memory was
added or removed, then memory may be bad.

No Boot Device Available

System did not find a device to boot.

Off Board Parity Error

A parity error occurred on an off-board card. This error is followed
by an address.

On Board Parity Error

A parity error occurred in onboard memory. This error is followed
by an address.

Parity Error

A parity error occurred in onboard memory at an unknown
address.

NVRAM / CMOS / PASSWORD
cleared by Jumper

NVRAM, CMOS, and passwords have been cleared. The system
should be powered down and the jumper removed.

 Pressed

CMOS is ignored and NVRAM is cleared. User must enter Setup.

Solving BIOS Problems

97

5 Getting Help
World Wide Web
http://support.intel.com/support/motherboards/server/S875WP1-E

Telephone
All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card
exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at
any time without notice).
In U.S. and Canada

1-800-404-2284

In Europe
UK
France
Germany
Italy
Spain

0870 6072439
01 41 918529
069 9509 6099
02 696 33276
91 377 8166

Finland
Denmark
Norway
Sweden
Holland

9 693 79297
38 487077
23 1620 50
08 445 1251
020 487 4562

Indonesian
Malaysia
New Zealand
Pakistan
Philippines
Thailand
Vietnam

001-803 65 7249
1-800 80 1390
0800 444 365
632 6368415 (IDD via Philippines)
1-800 1 651 0117
1-800 6310003
632 6368416 (IDD via Philippines)

In Asia-Pacific region
Australia
Hong Kong
Korea
PRC
Singapore
Taiwan
India

1800 649931
852 2 844 4456
822 767 2595
800 820 1100
65 213-1311
2 2545-1640
0006517-830 3634

In Japan
0120-868686 (Domestic)

81-298-47-0800 (outside country)

In Latin America
Brazil
Mexico
Colombia
Costa Rica
Panama
Chile
Miami

0021-0811-408-5540
001-800-628-8686
980-9-122-118
0-800-011-0395
001-800-628-8686
800-532-992
1-800-621-8423

Ecuador
Guatemala
Venezuela
Argentina
Paraguay
Peru
Uruguay

999-119, 800-628-8686 (via AT&T)
99-99-190, 800-628-8686 (via AT&T)
800-11-120, 800-628-8686 (via AT&T)
001-800-222-1001, 800-628-8686 (via AT&T)
008-11, 800-628-8686 (via AT&T)
0-800-50000, 800-628-8686 (via AT&T)
000-410, 800-628-8686 (via AT&T)

* Or contact your local dealer or distributor.
For an updated support contact list, please see http://www.intel.com/support/9089.htm.

Getting Help

99

6 Technical Reference
Server Board Connectors
CAUTION
Many of the baseboard and front panel connectors provide operating voltage
(+5 V DC and +12 V DC, for example) to devices inside the server chassis,
such as fans and internal peripherals. These connectors are not overcurrent
protected. Do not use these connectors for powering devices external to the
server chassis. A fault in the load presented by the external devices could
cause damage to the server, the interconnecting cable, and the external
devices themselves.

✏

NOTE
A standard ATX 20 pin power connector and standard ATX 12V 4 pin 2x2
connector can be used to power the server board S875WP1-E. Plug the
power cables into the pin 1 end of their respective motherboard connectors,
leaving pins 21-24 unused on the main power connector and 5-8 unused on
the 12V connector.

Technical Reference

101

Baseboard Connectors
Power, Fan, Chassis Intrusion Connectors
Figure 24 shows the power, fan, and chassis intrusion connectors.

J1B1

A

B

J1F1

12 V

C

D
I
E
J6J3

F

J7B1

J6J2

H

G
TP00195

J9A1

A.
B.
C.
D.

Chassis fan
Processor fan
Main power
Auxiliary power

E.
F.
G.
H.

Chassis fan
Chassis fan
Chassis intrusion
+12V power

Figure 24. Power, Fan, and Chassis Intrusion Connectors

102

Intel Server Board S875WP1-E Product Guide

Add-In Board and Peripheral Interface Connectors
Figure 25 shows the add-in board and peripheral interface connectors.

L

K

J

A
T
A
1
0
0

A
B
C

D

E

F

G

H

I

Serial ATA

TP00199

A.
B.
C.
D.
E.
F.

PCI slot 1
PCI slot 2
PCI slot 3
Serial ATA Drive SATA-A4 (S875WP1LX only)
Serial ATA Drive SATA-A2 (S875WP1LX only)
Serial ATA Drive SATA-A3 (S875WP1LX only)

G.
H.
I.
J.
K.

Serial ATA Drive SATA-A1 (S875WP1LX only)
Serial ATA Drive SATA-B1
Serial ATA Drive SATA-B2
Secondary IDE
Primary IDEFloppy drive

Figure 25. Add-in Board and Peripheral Interface Connectors

Technical Reference

103

Server Board Resources
Memory Map
Table 44.

System Memory Map

Address Range (decimal)

Address Range (hex)

Size

Description

1024 K - 4194304 K

100000 - FFFFFFFF

4095 MB

Extended memory

960 K - 1024 K

F0000 - FFFFF

64 KB

Runtime BIOS

896 K - 960 K

E0000 - EFFFF

64 KB

Reserved

800 K - 896 K

C8000 - DFFFF

96 KB

Available high DOS memory (open
to the PCI bus)

640 K - 800 K

A0000 - C7FFF

160 KB

Video memory and BIOS

639 K - 640 K

9FC00 - 9FFFF

1 KB

Extended BIOS data (movable by
memory manager software)

512 K - 639 K

80000 - 9FBFF

127 KB

Extended conventional memory

0 K - 512 K

00000 - 7FFFF

512 KB

Conventional memory

DMA Channels
Table 45.

104

DMA Channels

DMA Channel Number

Data Width

System Resource

0

8 or 16 bits

Open

1

8 or 16 bits

Parallel port

2

8 or 16 bits

Diskette drive

3

8 or 16 bits

Parallel port (for ECP or EPP)

4

8 or 16 bits

DMA controller

5

16 bits

Open

6

16 bits

Open

7

16 bits

Open

Intel Server Board S875WP1-E Product Guide

I/O Map
Table 46.

I/O Map

Address (hex)

Size

Description

0000 - 00FF

256 bytes

0170 - 0177
01F0 - 01F7

8 bytes
8 bytes

Used by the Server Board S875WP1-E. Refer to the ICH5-R data
sheet for dynamic addressing information.
Secondary IDE channel
Primary IDE channel

0228 - 022F (Note 1)
0278 - 027F (Note 1)
02E8 - 02EF (Note 1)
02F8 - 02FF (Note 1)
0376
0377, bits 6:0
0378 - 037F
03B0 - 03BB
03C0 - 03DF
03E8 - 03EF
03F0 - 03F5
03F6
03F8 - 03FF
04D0 - 04D1
LPTn + 400
0CF8 - 0CFB (Note 2)
0CF9 (Note 3)
0CFC - 0CFF
FFA0 - FFA7
FFA8 - FFAF

8 bytes
8 bytes
8 bytes
8 bytes
1 byte
7 bits
8 bytes
12 bytes
32 bytes
8 bytes
6 bytes
1 byte
8 bytes
2 bytes
8 bytes
4 bytes
1 byte
4 bytes
8 bytes
8 bytes

LPT3
LPT2
COM4/video (8514A)
COM2
Secondary IDE channel command port
Secondary IDE channel status port
LPT1
Intel 82875P MCH
Intel 82875P MCH
COM3
Diskette channel 1
Primary IDE channel command port
COM1
Edge/level triggered PIC
ECP port, LPTn base address + 400h
PCI configuration address register
Reset control register
PCI configuration data register
Primary bus master IDE registers
Secondary bus master IDE registers

Notes:
1.

Default, but can be changed to another address range

2.

Dword access only

3.

Byte access only

Technical Reference

105

Interrupts
The interrupts can be routed through the Advanced Programmable Interrupt Controller (APIC)
portion of the ICH5-R component. The APIC is supported in Windows* 2000 Server and Windows
XP and supports a total of twenty-four interrupts.
Table 47.

Interrupts

IRQ

System Resource

NMI

I/O channel check

0

Reserved, interval timer

1

Reserved, keyboard buffer full

2

Reserved, cascade interrupt from slave PIC

3

COM2 (Note 1)

4

COM1 (Note 1)

5

LPT2 (Plug and Play option)/User available

6

Diskette drive

7

LPT1 (Note 1)

8

Real-time clock

9

Reserved for ICH5-R system management bus

10

User available

11

User available

12

Onboard mouse port (if present, else user available)

13

Reserved, math coprocessor

14

Primary IDE (if present, else user available)

15

Secondary IDE (if present, else user available)

16

USB UHCI controller 1 (through PIRQA)

17

User available (through PIRQB)

18

ICH5-R USB controller 3 (through PIRQC)

19

ICH5-R USB controller 2 (through PIRQD)

20

ICH5-R LAN (through PIRQE)

21

User available (through PIRQF)

22

User available (through PIRQG)

23

ICH5-R USB 2.0 EHCI controller/User available (through PIRQH)

Note:
1.

106

Default, but can be changed to another IRQ.

Intel Server Board S875WP1-E Product Guide

7 Regulatory and Integration Information
Product Regulatory Compliance
Product Safety Compliance
The server board S875WP1-E complies with the following safety requirements:
• UL 1950 - CSA 950 (US/Canada)
• EN 60 950 (European Union)
• IEC60 950 (International)
• CE – Low Voltage Directive (73/23/EEC) (European Union)
• EMKO-TSE (74-SEC) 207/94 (Nordics)
• GOST R 50377-92 (Russia)

Product EMC Compliance
The server board S875WP1-E has been has been tested and verified to comply with the following
electromagnetic compatibility (EMC) regulations when installed a compatible Intel® host system.
For information on compatible host system(s) refer to Intel’s Server Builder website or contact your
local Intel representative.
• FCC (Class A Verification) – Radiated & Conducted Emissions (USA)
• ICES-003 (Class A) – Radiated & Conducted Emissions (Canada)
rd
• CISPR 22, 3 Edition (Class A) – Radiated & Conducted Emissions (International)
• EN55022 (Class A) – Radiated & Conducted Emissions (European Union)
• EN55024 (Immunity) (European Union)
• CE – EMC Directive (89/336/EEC) (European Union)
• VCCI (Class A) – Radiated & Conducted Emissions (Japan)
• AS/NZS 3548 (Class A) – Radiated & Conducted Emissions (Australia / New Zealand)
• RRL (Class A) Radiated & Conducted Emissions (Korea)
• BSMI CNS13438 (Class A) Radiated & Conducted Emissions (Taiwan)
• GOST R 29216-91 (Class A) Radiated & Conducted Emissions (Russia)
• GOST R 50628-95 (Immunity) (Russia)

Regulatory and Integration Information

107

Product Regulatory Compliance Markings
This product is marked with the following Product Certification Markings:
Table 48.

Product Certification Markings

UL Recognition Mark

CE Mark

Russian GOST Mark

Australian C-Tick Mark

BSMI DOC Marking

BSMI EMC Warning

RRL MIC Mark

108

Intel Server Board S875WP1-E Product Guide

Electromagnetic Compatibility Notices
FCC (USA)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
For questions related to the EMC performance of this product, contact:
Intel Corporation
5200 N.E. Elam Young Parkway
Hillsboro, OR 97124
1-800-628-8686
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment to an outlet on a circuit other than the one to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the grantee of this device could void the
user’s authority to operate the equipment. The customer is responsible for ensuring compliance of
the modified product.
Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC
Class A or B limits may be attached to this computer product. Operation with noncompliant
peripherals is likely to result in interference to radio and TV reception.
All cables used to connect to peripherals must be shielded and grounded. Operation with cables,
connected to peripherals, that are not shielded and grounded may result in interference to radio and
TV reception.

Regulatory and Integration Information

109

Industry Canada (ICES-003)
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital
apparatus set out in the interference-causing equipment standard entitled: “Digital Apparatus,”
ICES-003 of the Canadian Department of Communications.
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils
numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Apparelis
Numériques”, NMB-003 édictee par le Ministre Canadian des Communications.

Europe (CE Declaration of Conformity)
This product has been tested in accordance to, and complies with the Low Voltage Directive
(73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to
illustrate its compliance.

Taiwan Declaration of Conformity
This product has been tested and complies with CNS13438. The product has been marked with the
BSMI DOC mark to illustrate compliance.

Korean RRL Compliance
This product has been tested and complies with MIC Notices No. 1997-41 and 1997-42. The
product has been marked with the MIC logo to illustrate compliance.

The English translation for the above is as follows:
1. Type of Equipment (Model Name): S875WP1-E
2. Certification No.: Contact Intel Representative
3. Name of Certification Recipient: Intel
4. Date of Manufacturer: Marked on Product
5. Manufacturer / Nation : Intel

Australia / New Zealand
This product has been tested and complies with AS/NZS 3548. The product has been marked with
the C-Tick mark to illustrate compliance.

110

Intel Server Board S875WP1-E Product Guide

Installation Precautions
When you install and test the server board, observe all warnings and cautions in the installation
instructions.
To avoid injury, be careful of:
• Sharp pins on connectors
• Sharp pins on printed circuit assemblies
• Rough edges and sharp corners on the chassis
• Hot components (like processors, voltage regulators, and heat sinks)
• Damage to wires that could cause a short circuit
Observe all warnings and cautions that instruct you to refer computer servicing to qualified
technical personnel.

Installation Requirements
CAUTION
Follow these guidelines to meet safety and regulatory requirements when
installing this board assembly.
Read and adhere to all of these instructions and the instructions supplied with the chassis and
associated modules. If the instructions for the chassis are inconsistent with these instructions or the
instructions for associated modules, contact the supplier’s technical support to find out how you can
ensure that your computer meets safety and regulatory requirements. If you do not follow these
instructions and the instructions provided by chassis and module suppliers, you increase safety risk
and the possibility of noncompliance with regional laws and regulations.

Prevent Power Supply Overload
Do not overload the power supply output. To avoid overloading the power supply, make sure that
the calculated total current loads of all the modules within the computer is less than the output
current rating of each of the power supplies output circuits.

Regulatory and Integration Information

111

Place Battery Marking
There is insufficient space on this server board to provide instructions for replacing and disposing
of the battery. For system safety certification, the following statement or equivalent statement may
be required to be placed permanently and legibly on the chassis near the battery.

CAUTIONS
Risk of explosion if battery is incorrectly replaced.
Replace with only the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.

Use Only for Intended Applications
This server board was evaluated as Information Technology Equipment (I.T.E.) for use in
computers that will be installed in offices, homes, schools, computer rooms, and similar locations.
The suitability of this product for other applications or environments, (such as medical, industrial,
alarm systems, test equipment, etc.) may require further evaluation.

112

Intel Server Board S875WP1-E Product Guide



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Modify Date                     : 2003:04:18 08:27:52Z
Subject                         : Bonham Board
Create Date                     : 2003:04:18 08:27:52Z
Page Count                      : 112
Creation Date                   : 2003:04:18 08:27:52Z
Mod Date                        : 2003:04:18 08:27:52Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Nancy Phillips
Metadata Date                   : 2003:04:18 08:27:52Z
Creator                         : Nancy Phillips
Title                           : Intel Server Board S815EBM Product Guide
Description                     : Bonham Board
Page Mode                       : UseNone
EXIF Metadata provided by EXIF.tools

Navigation menu