TVD-LWB-2 L-shaped Wall Bracket Installation Instructions Description Dimensions: Weight: Screw C 4 x 25 mm (4 pcs ) (Used for attaching brackets to the wall) Drywall anchor 6 x 29 mm (4 pcs ) Black rubber circular liner A (The liner may be used between the wall mount and camera back box to minimize the impact from dust, dirt, or moisture.) Black rubber circular liner B (The liner may be used between the wall mount and camera back box to minimize the impact from dust, dirt, or moisture.) 100 × 162 × 70 mm (3.93 × 6.38 × 2.75 in.) 265 g (0.58 lb.) Accessories: Screw A 4 pcs (Used for attaching the camera to the brackets) Screw B 4 pcs (Used for attaching the camera to the brackets) Supported cameras: Hole 1 TruVision IP S3 VF dome TVD-5303, TVD-5304, TVD-5305, TVD-5306, TVD-5307 © 2017 United Technologies Corporation. P/N 1072967-EN • REV B • ISS 22NOV17 Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved. Hole 2 TruVision HD-TVI VF dome with back box NTSC: TVD-4402, TVD-4404, TVD-4405, TVD-4406 PAL: TVD-2402, TVD-2404, TVD-2405, TVD-2406 TruVision 960H analog VF dome with back box NTSC: TVD-4202 PAL: TVD-2202 TruVision IP S4 VF dome TVD-5401, TVD-5402, TVD-5403 TruVision IP S4 VF dome TVD-5404, TVD-5405, TVD-5406, TVD-5407, TVD-5408 Installation To attach a dome that includes an adapter mounting plate that uses Hole 2 (see the Supported cameras list) to a TVD-LWB-2 bracket: 1. Attach the bracket to the wall by using the four C screws and drywall anchors, if required. 2. Attach the adaptor plate to the TVD-LWB-2 bracket using the four A screws into holes 2 (see Dimensions). To attach a dome that uses Hole 1 (see the Supported cameras list) to a TVD-LWB-2 bracket: 1. Attach the bracket to the wall by using the four C screws and drywall anchors, if required. 2. Remove the bubble assembly from the housing and attach the dome to the bracket by inserting three A screws into holes 1 (see Dimensions). 3. Attach the camera by rotating it to lock the camera to the adapter. 3. Finish cabling and lens adjustment, then attach the bubble assembly to the camera. 4. Finish cabling and lens adjustment. 2/4 P/N 1072967-EN • REV B • ISS 22NOV17 To attach an analog VF dome that uses Hole 2 (see the Supported cameras list) to a TVD-LWB-2 bracket: 1. Attach the bracket to the wall by using the four C screws and drywall anchors, if required. 2. Optional. Drill holes in the black rubber circular liner A to line up with the holes in the back box. 3. Remove the housing from the back box. 4. Attach the black rubber circular liner A to the bottom of the back box. 5. Attached the back box to the TVD-LWB-2 bracket by inserting the four A or B (depending on your preference) screws into holes 2 (see Dimensions). 6. Install the camera to back box with the screws included in the camera package (refer to the dome installation instructions). P/N 1072967-EN • REV B • ISS 22NOV17 7. Finish cabling and lens adjustment, then attach the bubble assembly to the camera. To attach a motorized VF dome that uses Hole 2 (see the Supported cameras list) to a TVD-LWB-2 bracket: 1. Attach the bracket to the wall by using the four C screws and drywall anchors, if required. 2. Optional. Drill holes in the black rubber circular liner B to line up with the holes in the back box. 3. Remove the housing from the back box. 4. Attach the black rubber circular liner B to the bottom of the back box. 5. Attached the back box to the TVD-LWB-2 bracket by inserting the four A or B (depending on your preference) screws into holes 2 (see Dimensions). 3/4 6. Remove the bubble assembly and install the camera to the back box with the screws included in camera package (refer to the dome installation instructions). Regulatory information Trademarks and patents The trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Certification Product warnings and disclaimers 7. THESE PRODUCTS ARE INTENDED FOR SALE TO, AND INSTALLATION BY, AN EXPERIENCED SECURITY PROFESSIONAL. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL SECURITY RELATED PRODUCTS. For more information on warranty disclaimers and product safety information, please check www.firesecurityproducts.com/policy/productwarning/ or scan the following code: Finish cabling and lens adjustment, and reinstall the bubble assembly to the camera. Contact information and manuals For contact information go to: www.interlogix.com or www.firesecurityproducts.com To get translations for this and other product manuals go to: www.firesecurityproducts.com 4/4 P/N 1072967-EN • REV B • ISS 22NOV17
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Modify Date : 2017:11:22 10:12:45-05:00 Create Date : 2017:11:22 08:10:02+01:00 Metadata Date : 2017:11:22 10:12:45-05:00 Creator Tool : Acrobat PDFMaker 10.1 for Word Document ID : uuid:da688772-517b-413a-a5b5-d3cb15b447c4 Instance ID : uuid:ef6a0599-bf76-44d5-b533-9e721c5fc085 Subject : 2 Format : application/pdf Title : TVD-LWB-2 L-shaped Wall Bracket Installation Instructions Description : TVD-LWB-2 L-shaped Wall Bracket Creator : J ONeill Producer : Adobe PDF Library 10.0 Source Modified : D:20171122070915 Company : UTC Fire & Security Comments : R07 Template for Installation Sheet..Medium: Paper, A4, 08.27 x 11.69..Layout: Portrait, duplex with 0.22 binding..Columns: 2 x 3.50 with 0.25 gutter Category : Installation Instructions Part 0020number : 1072967-EN Revision 0020date : 22NOV17 Revision 0020number : B Model 0020name : TVD-LWB-2 L-shaped Wall Bracket Model 0020number : Chop : P/N 000000-XX • REV 01 • DRAFT 00.01 Language : EN Headline : TVD-LWB-2 L-shaped Wall Bracket Page Layout : OneColumn Page Count : 4 Author : J ONeill Model Name : TVD-LWB-2 L-shaped Wall Bracket Model Number : Part Number : 1072967-EN Revision Date : 22NOV17 Revision Number : BEXIF Metadata provided by EXIF.tools