FTP 1000 Touchpad/Display Installation Manual Touchpad Display Install 466 2231 REV B
2015-08-27
: InterLogix Ftp-1000 Touchpad-Display Install Manual 466-2231 Rev B FTP-1000_Touchpad-Display_Install Manual_466-2231 REV B library
Open the PDF directly: View PDF .
Page Count: 11
Download | |
Open PDF In Browser | View PDF |
FTP-1000 Touchpad/Display Installation Manual A B Stay P/N 466-2231 • REV B • January 2011 1 2 3 4 5 6 7 8 9 * 0 # Away Disarm C Quick Exit D Copyright Copyright © 2011 Interlogix, a UTC Fire & Security Company. All rights reserved. This document may not be copied or otherwise reproduced, in whole or in part, except as specifically permitted under US and international copyright law, without the prior written consent from UTC fire & Security Company. Document number/revision: 466-2231B (January 2011). Disclaimer THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. UTC FIRE & SECURITY ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR OMISSIONS AND SPECIFICALLY DISCLAIMS ANY LIABILITIES, LOSSES, OR RISKS, PERSONAL OR OTHERWISE, INCURRED AS A CONSEQUENCE, DIRECTLY OR INDIRECTLY, OF THE USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE LATEST DOCUMENTATION, CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT WWW.UTCFIREANDSECURITY.COM. This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental. Trademarks and patents FTP-1000 touchpad/display product and logo are registered trademarks of UTC Fire and Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Manufacturer UTC Fire & Security Americas Corporation, Inc. 1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA Intended use Use this product only for the purpose it was designed for; refer to the data sheet and user documentation. For the latest product information, contact your local supplier or visit us online at www.utcfireandsecurity.com. FCC compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Contact information For contact information, see www.utcfireandsecurity.com. Product overview The FTP-1000 lets you control the operation of compatible security systems (see Appendix A). The large display provides easy to read messages to indicate the current status of the system. The touchpad includes police, fire, and auxiliary panic buttons that can be activated anytime. A built-in speaker provides alarm, status, and buttonpress sounds. A swing-down door reveals a label with basic system operating commands. The door can be removed by simply opening it past its stop point. The door can also be reattached later if desired. Tools and equipment needed • 4-conductor, 22- or 18-gauge wire • Screwdriver • #6 screws and anchors (included) • Panhead screws for gang box installation • Saw or utility knife for cutting wallboard Installation Use the following instructions to install and wire your touchpad. Guidelines • Mount the touchpad in an environmentally controlled area (32 to 120°F or 0 to 49°C). • When mounting the touchpad, allow at least 3 inches below it for the swingdown cover. • Do not exceed the maximum available power. See the panel installation instructions for maximum available power. • Table 1 describes the power used by the touchpad. • Table 2 describes the maximum wire lengths allowed between the touchpad and the panel. Table 1: Touchpad power usage Current (mA) Conditions 75 Maximum alarm current with the buzzer sounding and the touchpad illuminated from a button press 50 Typical operation FTP-1000 Touchpad/Display Installation Manual 1 12 Power saving mode (no panel AC power) Table 2: Touchpad power usage Wire gauge (unshielded or shielded) Max touchpad wire length between touchpad and panel 18 750 feet 22 300 feet Mounting plate installation To install the mounting plate, do the following: 1. Separate the mounting plate from the touchpad by first loosening the screw, then lift the touchpad away from the mounting plate (see Figure 1). Figure 1. Mounting plate screw Mounting plate screw 2. For wall mounting, place the mounting plate on the wall and mark the mounting holes (see Figure 2). Be sure to leave a 3-inch clearance below for the touchpad door to open. 2 FTP-1000 Touchpad/Display Installation Manual Figure 2. Mounting hole locations 3. Insert anchors into the wall at the marked locations where studs are not present. 4. Align the mounting plate holes with the wall or gang box screw holes and secure the back plate using the screws provided. Note: Do not overtighten screws or the mounting plate may bind and prevent the touchpad from mounting properly. 5. For wall-mount installations, cut a hole in the wall behind the mounting plate to pull the wiring cable through. Wiring the touchpad to the panel To wire the touchpad to the panel, do the following: 1. Remove panel AC and backup battery power. 2. Run a 4-conductor, 18- to 22-gauge wire from the panel to the touchpad location (see Table 2). 3. Connect the touchpad +12V, Bus A, Bus B, and GND terminals to the matching panel terminals (Figure 3). Note: The wiring should extend from the right side of the connector. FTP-1000 Touchpad/Display Installation Manual 3 Figure 3. Touchpad wiring connections +12V GND Bus B Bus A Attaching the touchpad to the mounting plate Align the tabs at the top of the mounting plate with the slots on the touchpad and swing the touchpad bottom toward the mounting plate. Gently tighten the screw into the bottom of the touchpad. Power-up and bus communication After making all wiring connections from the touchpad to the panel, you are ready to power up the panel and verify correct communication between the touchpad and the panel. Upon power-up, the panel scans the bus for connected devices and automatically learns the unit number of each bus device. Note: If you plan to install systems with no alphanumeric touchpads, we recommend that you keep an alphanumeric touchpad with you, specifically for installer programming. This touchpad can be quickly connected and disconnected from the header pins on the lower-left portion of the panel, just above the terminal strip. To power up the panel and verify bus communication: 1. Verify that all wiring between the panel and touchpad is correct. 2. Connect the panel battery and plug in the panel transformer. The touchpad should display BUS SCAN, then show a time display with the PRESS STATUS prompt in the upper-left corner. Note: If the touchpad does not power up (show any display) or respond as described above, unplug the panel AC transformer and disconnect the backup battery. See Troubleshooting section for more information. 4 FTP-1000 Touchpad/Display Installation Manual Testing Use the following procedures to test the touchpad for display function, button function, and system operation. Test touchpad display function Press and hold the 4, 5, and 6 buttons together for about three seconds, then release them. The touchpad cycles though all text messages, then returns to the time display. Test button function To test the button functions, do the following: 1. Press and hold the 7, 8, and 9 buttons together for about three seconds, then release them. The display should go blank. 2. Press each touchpad button to display a different string of letters or numbers for each button. For example, 11111111111, AAAAAAAAAAA, etc. Pressing * displays Es and pressing # displays Fs. After about 15 seconds of no touchpad activity, the touchpad returns to the time display. Test system operation Testing the system operation requires you to perform some standard operations to ensure that they work properly. Caution: Contact the central monitoring station before activating alarms, to avoid dispatching local police and fire departments. To test the system’s operation, do the following: Arm/disarm the system, activate the touchpad panics, bypass sensors, and turn chime on/off to verify correct operation. Note: You must enable the touchpad panic buttons in order to activate them. Please see the panel installation instructions for more information. Refer to the panel’s user manual for complete system operating instructions and user programming procedures. Adjusting display brightness You can adjust the background lighting (provided by yellow LEDs) of each touchpad individually to help compensate for lighting conditions at the touchpad location. The brightness adjustment lightens or darkens the display background and button lighting. FTP-1000 Touchpad/Display Installation Manual 5 Adjust display background brightness To adjust display background brightness, do the following: 1. Enter user programming mode by pressing 9 + system master code. The display shows SYSTEM MENU, then TIME - dATE. 2. Press A or B until the display shows OPTIONS, then press #. The display shows dOWnLd ON. 3. Press A or B until the display shows BRIgHT 2 (default setting). 4. Enter a setting from 0 (LEDs off) to 3 (brightest), then press #. The display shows the new setting. 5. Exit user programming by pressing: • * + 4 + # for Concord Express panels, • or * + 00 + # for Concord panels. Changing chime and trouble beep tones The frequency (pitch) of chime and trouble beep tones from each touchpad can be adjusted to a more desirable or distinct tone, and to compensate for hearing impaired persons. Note: Chime and trouble beep tones sound (using the default frequency) during, or within 15 seconds of any button activity at that specific touchpad. Change status tone pitch To change the status tone pitch, do the following: 1. Press and hold the * and 0 buttons together until you hear a steady tone, then release the buttons. 2. Press and hold 1 to lower the pitch or press and hold 2 to raise the pitch. 3. Release the button when the desired pitch is heard. After about 15 seconds of no touchpad activity, the steady tone stops sounding. Troubleshooting The following describes what to do if the touchpad does not operate correctly. The touchpad doesn’t power up (no display and no beeps when buttons are pressed). • Check for correct wiring connections at touchpad and panel terminals. • Make sure that the panel battery is connected correctly and that the panel transformer is plugged in. 6 FTP-1000 Touchpad/Display Installation Manual • Make sure panel transformer is not plugged into an electrical outlet controlled by a switch. Relocate the transformer to an unswitched outlet location, if necessary. The touchpad display appears blank, but beeps sound when I press buttons. • Check for correct bus wiring connections (green and white wires) at touchpad and panel terminals. Contact information For contact information, see www.utcfireandsecurity.com or www.interlogix.com. For technical support, toll-free: 888.437.3287 in the US including Alaska, Hawaii, Puerto Rico, and Canada. Outside the tool-free area, contact your dealer. FTP-1000 Touchpad/Display Installation Manual 7 Appendix A>Specifications and notices Specification Rating Compatibility Concord, Concord Express, Concord Ultra, Concord 4 Power requirements 12 VDC nominal, 75 mA Temperature range 32 to 120°F (0 to 49°C) Operating -30 to 140°F (-34 to 60°C) Storage Maximum humidity 85% relative, noncondensing Dimensions 5 in. x 4.50 in. x 0.75 in. (L x W x D) UL/cUL listings UL (985, 1023, 1610) cUL (C1023 - 1974, S545 - M89) For cUL listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code. Note: See specific panel installation instructions for complete UL installation requirements for the system you are installing. Radio interference information to the user If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits. • Consult the dealer or an experienced radio/TV technician help. 8 FTP-1000 Touchpad/Display Installation Manual
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Bob Nelson Category : IP Type Comments : R01 Template for UTCFS Manual Medium..Medium: Paper, letter, 08.50 x 11.00..Layout: Portrait, duplex with 0.50 binding..Columns: 1 x 06.00.. Company : UTC Fire & Security Create Date : 2011:01:05 13:00:22-06:00 Modify Date : 2013:08:15 10:48:11-07:00 Part Number : 466-2231 Revision Date : 30DEC10 Revision Number : B Source Modified : D:20110105185737 Subject : FTP-1000 Touchpad/Display Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : Acrobat PDFMaker 9.1 for Word Metadata Date : 2013:08:15 10:48:11-07:00 Producer : Acrobat Distiller 9.4.0 (Windows) Keywords : Format : application/pdf Creator : Bob Nelson Title : FTP-1000 Touchpad/Display Installation Manual Description : FTP-1000 Touchpad/Display Document ID : uuid:445572bb-6c59-4215-a29a-d651f6c6970a Instance ID : uuid:d78297fd-48b4-436d-a7ae-80572b0a1bab Part 0020number : 466-2231 Revision 0020date : 30DEC10 Revision 0020number : B Headline : FTP-1000 Touchpad/Display Page Layout : OneColumn Page Count : 11EXIF Metadata provided by EXIF.tools