Intrusion Wireless LTE & GSM Modules For use with NetworX Systems OVERVIEW STANDARD FEATURES Cellular modules enable the NetworX series of security panels to communicate signals wirelessly over either LTE or 3G HSPA cellular networks. This provides users with Alarm.com®’s secure wireless signaling and convenient functionality including real-time event notification, Web-based remote monitoring and other home system control capabilities. • U.S. cellular coverage covers more than 95% of U.S. population* • Canadian cellular coverage covers more than 90% of Canada’s population* • Remote monitoring and control for convenient system access from virtually anywhere • Remote programming via AirFx™ toolkit troubleshoots issues without expensive "truck rolls" • Z-Wave class modems control lighting, thermostat and more • Cellular module can be located up to 90 ft. (27.4m) from the main control panel • LED status lights display signal strength and simplify troubleshooting The digital wireless communication also enables secure alarm reporting to a central station via SIA or Contact ID, regardless of whether a phone line is installed at the system location. Users can remotely monitor and control their security system via smartphone, tablet or via the Alarm.com website. Features include viewing system status and history, arming and disarming the system, setting up user codes and creating customized email and text message notifications for any type of alarm or non-alarm activity at the property. Additionally, using the Z-Wave® enabled modems enables the control of Z-Wave class devices such as lighting and thermostats. The modules interface with the NetworX panel data bus and are powered by the panel. Status LEDs on the module allow for cellular signal strength checking, as well as troubleshooting during installation. The cellular module can be used as the primary means of communication or as a backup to a landline phone connection. Each NetworX panel supports a maximum of one wireless module. For added peace of mind, an optional tamper detection switch is available that signals when the module cover is removed. *Based on publicly available information from cellular providers and industry reports. interlogix.com/networx Wireless LTE & GSM Modules For use with NetworX Systems Specifications Compatibility NetworX Panels: NX V2 4, 6, 8 and 8E. (Note: certain older V1 NX4, 6 and 8 may not be fully supported) Power requirements 9.5 to 15 VDC, 12 V nominal, 65mA (continuous) 1600mA (instantaneous peaks) maximum (from panel or auxiliary power supply) Power/data bus One three-wire NetworX power/communication data bus Cellular network Verizon® LTE, 3G HSPA AT&T™, T-Mobile® or Rogers LED indicators One module/panel communication status LED, one module power LED, one automation LED, three wireless communication status LEDs and 4 GSM status LEDs Dimensions (H x W x D) 5.25 x 4.125 x 1 in. (133 x 105 x 25mm) Case material High impact, ABS plastic, Belgian gray Operating temperature 32°F to 120°F (0°C to 49°C) Storage temperature -30°F to 140°F (-34°C to 60°C) Humidity 90% relative humidity Listings FCC Part 15, IC Ordering Information NX-592E-LTE-ZX-VZ NetworX LTE Cellular Module; Alarm.com w/Z-Wave®, Verizon NX-592E-GSM-ZX-AT NetworX Cellular Module; Alarm.com HSPA 3G GSM w/Z-Wave, AT&T NX-592E-GSM-ZX-RG NetworX Cellular Module; Alarm.com HSPA 3G GSM w/Z-Wave, Rogers (Canada Use Only) NX-592E-GSM-ZX-TM NetworX Cellular Module; Alarm.com HSPA 3G GSM w/Z-Wave, T-Mobile interlogix.com Specifications subject to change without notice. Z-Wave® is a registered US Trademark of Zensys A/S. Complies with FCC and Industry Canada regulations. © 2017 United Technologies Corporation. All rights reserved. All trademarks are the property of their respective owners. Interlogix is part of UTC Climate, Controls & Security a unit of United Technologies Corporation. 2017/02 (GSP-2302)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c137 79.159768, 2016/08/11-13:24:42 Create Date : 2017:02:06 10:40:25-05:00 Modify Date : 2017:02:06 10:40:26-05:00 Metadata Date : 2017:02:06 10:40:26-05:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:8ad3bf31-8a87-489c-84dd-eb3bbf69310f Version ID : 1 Original Document ID : adobe:docid:indd:eefb600d-eaf6-11de-b286-887d7b40b072 Document ID : xmp.id:72f3bc11-57d7-3641-b4fb-cf2eb8787fae Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:3e074e98-3696-5f43-91b9-7e8c2552e26f Derived From Document ID : xmp.did:46efbf0f-4376-f743-a282-a967e176c89a Derived From Original Document ID: adobe:docid:indd:eefb600d-eaf6-11de-b286-887d7b40b072 Derived From Version ID : 1 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:02:06 10:40:25-05:00 Format : application/pdf Rights : Copyright General Electric Company. All rights reserved. It is our intention to keep the product information current and accurate. We can not cover specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information or questions relative to this data sheet, contact GE Security. Description : GE Security Product Data Sheet: Access Control, Enclosures, M5 Enclosure for Picture Perfect & Secure Perfect Title : Data Sheet -- M5 Enclosure for Picture Perfect & Secure Perfect Creator : JE Subject : Access Control, Card Access, Enclosures Web Statement : http://www.gesecurity.com Marked : True Producer : Adobe PDF Library 15.0 Trapped : False Job Ref Name : XMP_Example_2004 Page Count : 2 Author : JEEXIF Metadata provided by EXIF.tools