TruVision Stainless Steel Dome Camera Installation Guide 1073434a En
2018-06-15
: Interlogix 1073434A-Truvision-Stainless-Steel-Dome-Camera-Installation-Guide-En 1073434a-truvision-stainless-steel-dome-camera-installation-guide-en library
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
TruVision Stainless Steel Dome Camera Installation Guide P/N 1073434-EN • REV A • ISS 27FEB18 Copyright Trademarks and patents Manufacturer © 2018 United Technologies Corporation, Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved. Trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Interlogix 2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands Certification FCC compliance Class A: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC conditions This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This Device must accept any interference received, including interference that may cause undesired operation. ACMA compliance Notice! This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Canada This Class A digital apparatus complies with CAN ICES-003 (A)/NMB-3 (A). Cet appareil numérique de la classe A est conforme à la norme CAN ICES-003 (A)/NMB-3 (A). This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU. European Union directives 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. Product warnings and disclaimers THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS. For more information on warranty disclaimers and product safety information, please check www.firesecurityproducts.com/policy/product-warning/ or scan the QR code: Contact information and manuals For contact information go to: www.interlogix.com or www.firesecurityproducts.com To get translations for this and other product manuals go to: www.firesecurityproducts.com Content Introduction 6 Product overview 6 Installation 6 Installation environment 6 Package contents 7 Camera description 9 IR illuminators 10 Alarm input and output connections 10 SD memory card installation 11 Mounting the dome camera 12 Mounting the TVJ-JBS junction box 12 Using the camera with an Interlogix NVR or Hybrid DVR or another system 12 Using the camera with TruVision Navigator 13 Access the camera over the internet 13 Specifications 16 Pin definitions 17 Installation Guide 5 Introduction Product overview This is the installation guide for the TruVision Stainless Steel dome camera model: • TVD-5801 (2MPX camera, 2.8-12 mm lens) Installation This section provides information on how to install the cameras. Installation environment When installing your product, consider these factors: • Electrical: Install electrical wiring carefully. It should be done by qualified service personnel. Always use a proper PoE switch or a 12 VDC UL listed Class 2 or CE certified power supply to power the camera. Do not overload the power cord or adapter. • Ventilation: Ensure that the location planned for the installation of the camera is well ventilated. • Temperature: Do not operate the camera beyond the specified temperature, humidity, or power source ratings. Humidity is below 90%. For the outdoor cameras that feature built-in heaters, the operating temperature range is -40 to 60°C (-40 to140°F) • Moisture: Do not expose the camera to rain or moisture or try to operate it in wet areas. Turn the power off 6 Installation Guide immediately if the camera is wet and ask a qualified service person for servicing. Moisture can damage the camera and also create the danger of electric shock. • Servicing: Do not attempt to service this camera yourself. Any attempt to dismantle or remove the covers from this product will invalidate the warranty and may also result in serious injury. Refer all servicing to qualified service personnel. • Cleaning: Do not touch the sensor modules with fingers. If cleaning is necessary, use a clean cloth with some ethanol and wipe the camera gently. If the camera will not be used for an extended period of time, put on the lens cap to protect the sensors from dirt. Package contents Check the package and contents for visible damage. If any components are damaged or missing, do not attempt to use the unit; contact the supplier immediately. If the unit is returned, it must be shipped back in its original packaging. Package contents include the following: Camera Installation guide IN DC12V Installation Guide 7 CD with configuration manual and TruVision Device Manager Equipment disposal sheet Battery disposal sheet Drill template Video test cable Screws Drywall anchor 7.5 × 24.5 mm (4 pcs) Screw M4 × 25 mm (4 pcs) Torx driver 8 Water joint: Provides water resistance to network cable connector Installation Guide CAUTION: Use direct plug-in UL listed power supplies marked Class 2/CE certified or LPS (limited power source) of the required output rating as listed on the unit. Camera description Figure 1: Dome camera description and connectors 3 2 4 5 1 10 11 12 13 IN DC12V 9 6 7 8 1. Bubble assembly 8. SD card slot 2. Lens 9. Video test port 3. Dome liner 10. Ethernet RJ45 PoE port 4. Rubber sealing 11. Alarm I/O 5. Base 12. Audio I/O 6. Reset button 13. 12 VDC power cable 7. Serial port (for internal use) Installation Guide 9 IR illuminators The camera’s built-in IR illumination provides high-quality video in low-light environments, even when there is no other illumination available. You can configure the IR illumination using a web browser or a client software, such as TruVision Navigator. If the function is enabled, the IR light is On when the camera enters night (black and white) mode. If disabled, the IR light is always Off. The visible IR range may vary due to multiple factors such as weather, IR reflection level of objects in frame, lens adjustment, and camera settings. Please refer to the camera datasheet for the standard IR range. Note: Avoid installing the IR camera in close proximity to a solid object such as a tree or wall. The reflection will cause over-exposure and loss of visibility of detail in the field of view. Alarm input and output connections The alarm output can be used to turn on and off an external alarm device. Connect a 30 VDC/1A external power supply to the alarm output. If using an AC power supply, an external relay must be used to prevent electric shock and damage to the device. See Figure 2 below. Figure 2: External alarm output 10 Installation Guide SD memory card installation To install the SD memory card in the dome camera 1. Loosen the three torx screws on the bubble assembly. 2. Insert the memory card into the SD card slot until it clicks into place. 3. Reinstall the bubble assembly on the camera base. Installation Guide 11 Mounting the dome camera To mount the dome on a wall: The TruVision Stainless Steel Dome Wall Mount (TVD-WBS, not included) is required to wall mount the dome camera. Refer to the installation guides provided with the TVD-WBS wall mount for instructions on mounting the stainless steel dome camera to the wall. To mount the dome on the ceiling: The TruVision Stainless Steel Pendant Mount (TVP-PAS, not included) is required to ceiling mount the dome camera. Refer to the installation guides provided with the TVP-PAS pendant mount for instructions on mounting the stainless steel dome camera to the ceiling. Mounting the TVJ-JBS junction box Refer to the installation guide provided with the TVJ-JBS junction box for instructions on mounting the camera in conjunction with the TVJ-JBS junction box. Using the camera with an Interlogix NVR or Hybrid DVR or another system Please refer to the NVR/DVR user manuals for instructions on connecting and operating the camera with these systems. 12 Installation Guide Using the camera with TruVision Navigator The camera can be connected to an Interlogix NVR, hybrid DVR, or directly to TruVision Navigator. Please refer to the user manual of TruVision Navigator and/or of the NVR or hybrid DVR for instructions. Access the camera over the internet Use the web browser to access and control the camera over the internet. Note: Any changes made to the camera’s configuration only apply to this camera. Only authorized users should be able to modify camera settings. When you first start up the camera, the Activation window appears. You must define a high-security admin password before accessing the camera. There is no default password provided. You can activate a password via a web browser and via TruVision Device Manager (included on the CD to find the IP address of the camera). To activate the camera via the web browser: 1. Power on the camera and connect the camera to the network. 2. Type the IP address into the address bar of the web browser and press Enter to enter the activation interface. Installation Guide 13 Note: 3. • The default IP address of the camera is 192.168.1.70. • For the camera to enable DHCP by default, you must activate the camera via TruVision Device Manager. Please refer to the following section, “To activate the camera via TruVision Device Manager.” Type the password in the Password field. Note: A valid password range must be between 8 and 16 characters. You can use a combination of numbers, lower and upper case letters, and special characters : _ - , . * & @ / $ ? Space. The password must contain characters from at least two of these groups. We also recommend that you reset your password regularly. For high security systems, it is particularly recommended to reset the password monthly or weekly for better protection. 4. Confirm the password. 5. Click OK to save the password and enter the live view interface. 14 Installation Guide 6. Click the Configuration tab on the top of the screen and select the parameter to change. Figure 3: Example of a configuration window To activate the camera via TruVision Device Manager: For instructions on how to activate the camera using TruVision Device Manager, refer to the TruVision Device Manager User Manual. Go to www.interlogix.com/video/product/truvisiondevice-manager and click Downloads. Installation Guide 15 Specifications Electrical Voltage input 12 VDC, PoE+ Power consumption Max. 16 W Miscellaneous Connectors Audio In/Out, Alarm In/Out, 12 VDC Power, Ethernet RJ45 PoE port Operating temperature -40 to +60°C (-40 to +140°F) Dimensions 165.4 × 130 mm (6.51 x 5.12 in.) Weight 3.36 kg (7.41 lb.) Environmental rating IP67 16 Installation Guide Pin definitions There are eight wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight and crossover cable connection: Figure 4: Straight-through cable 1 White/Orange 2 Orange 3 White-Green 4 Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown White/Orange 1 Orange 2 White-Green 3 Blue 4 White/Blue 5 Green 6 White/Brown 7 Brown 8 White/Orange 1 Orange 2 White-Green 3 Blue 4 White/Blue 5 Green 6 White/Brown 7 Brown 8 Figure 5: Cross-over cable 1 White/Orange 2 Orange 3 White-Green 4 Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown Ensure that the connected cables have the same pin assignment and color as above before deploying them in the network. Installation Guide 17 18 Installation Guide Installation Guide 19 20 Installation Guide
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Language : EN-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Modify Date : 2018:02:27 08:47:10-08:00 Create Date : 2018:02:27 08:46:41-08:00 Metadata Date : 2018:02:27 08:47:10-08:00 Creator Tool : Acrobat PDFMaker 11 for Word Document ID : uuid:741a9d1b-1192-449e-82e9-b780966b1e45 Instance ID : uuid:697929e7-c8eb-429f-bbb8-1a1e7d4e9bcd Subject : 8 Format : application/pdf Title : TruVision Stainless Steel Dome Camera Installation Guide Description : TruVision Stainless Steel Dome Camera Creator : Daniel Lapham Producer : Adobe PDF Library 11.0 Source Modified : D:20180227164630 Company : United Technologies Corporation Category : Installation Guide Part 0020number : 1073434-EN Revision 0020date : 27FEB18 Revision 0020number : A Language 0020code : EN Chop : P/N 000000-XX • REV 01 • DRAFT 00.01 Content Type Id : 0x0101005D71FB1E2E6FF14FAB462EA02A7580DE Headline : TruVision Stainless Steel Dome Camera Page Layout : OneColumn Page Mode : UseOutlines Page Count : 20 Author : Daniel Lapham Language Code : EN Part Number : 1073434-EN Revision Date : 27FEB18 Revision Number : AEXIF Metadata provided by EXIF.tools