Intermec Technologies 06CN3 CN3 User Manual 943 002
Intermec Technologies Corporation CN3 943 002
Contents
- 1. User Manual Compliance Insert
- 2. User Manual 1 of 6
- 3. User Manual 2 of 6
- 4. User Manual 3 of 6
- 5. User Manual 4 of 6
- 6. User Manual 5 of 6
- 7. User Manual 6 of 6
- 8. Compliance Insert
- 9. User Manual
- 10. Manual
- 11. Radio Info
- 12. User Manual part 1
- 13. User Manual part 2
- 14. User Manual part 3
- 15. User Manual part 4
User Manual
all subject to change to reflect IP30 use. Dave Fry Sr. EMC Engineer Feb. 28, 2008 Instructions chg photo chg title to IP30 IP4 Portable RFID Reader Contents Introducing the IP4 Portable RFID Reader . . . . . . . . . . . . . 3 What You Get . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Using the IP4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Charging and Installing the Battery . . . . . . . . . . . . 3 Attaching Your IP4 to a 700 Color. . . . . . . . . . . . . 5 (Optional) Configuring Your IP4 as a Keyboard Wedge . . . . . . . . . . . . . . . . . . . . . . . . 6 Reading an RFID Tag . . . . . . . . . . . . . . . . . . . . . . 8 Understanding the IP4 LEDs . . . . . . . . . . . . . . . . . . . . . . . . 9 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 all subject to change to reflect IP30 use. Dave Fry Sr. EMC Engineer Feb. 28, 2008 ii IP4 Portable RFID Reader Instructions Introducing the IP4 Portable RFID Reader The IP4 Portable RFID Reader is an accessory handle for the 700 Series Color mobile computers. Together, the IP4 and 700 Color provide a high-performance mobile RFID solution that allows you to bring the read/write device to the tagged product rather than moving tagged products past a fixed reader. What You Get • IP4 Portable RFID Reader • Battery (Model AB12) • Product documentation Using the IP4 To use the IP4, you need to perform these steps: 1 Charge and install the battery. 2 Attach your IP4 to a 700 Color. 3 (Optional) Configure your IP4 as a keyboard wedge. 4 Read an RFID tag. These instructions describe each step. Charging and Installing the Battery To charge the IP4 battery, you need the Dual Pack Battery Charger (Model AC12). To charge the IP4 battery • Insert the battery into a slot on the AC12 battery charger. A fully discharged battery charges in less than 4 hours. del 700 terminal mention terminals CK61 CN3 CN3e IP4 Portable RFID Reader Instructions To install the battery 1 Insert the battery tab on the top of the battery into the IP4. Battery tab 2 Firmly press the bottom of the battery onto the IP4 until the battery snaps into place. To remove the battery • Push the battery release latch on the bottom of the IP4. Battery release latch replace diagrams with IP30 IP4 Portable RFID Reader Instructions Attaching Your IP4 to a 700 Color Your IP4 uses Infrared Data Association (IrDA) to communicate with the 700 Color. The lightpipe in the IP4 helps communicate the IrDA signal between the 700 Color and your IP4. Lightpipe Note: Do not remove the lightpipe from the IP4. To attach your IP4 to a 700 Color 1 Slide the 700 Color into the IP4 until it clicks into place. chg diagrams consider adding seperate CK61 and CN3 installed diagrams IP4 Portable RFID Reader Instructions 2 Secure the retaining screws, making sure that they are inserted straight into the 700 Color. chg or del IP30 does not require screws for attachment del keyboard wedge discussion To remove your IP4 from a 700 Color 1 Remove the two retaining screws. 2 Hold the 700 Color at the display. 3 While lifting the 700 Color up (away from the IP4), pull the 700 Color forward and out of the IP4. (Optional) Configuring Your IP4 as a Keyboard Wedge You can configure your IP4 as a keyboard wedge to allow the 700 Color to receive data from your IP4 as it would from a keyboard. To use your IP4 as a keyboard wedge, the 700 Color and your IP4 must meet these requirements: • The 700 Color must have at least 64MB of flash ROM. • The fifth character in the configuration number (CN) found on the back of the 700 Color must not be a 4 or 5. For example: • 751B6xxxx meets this requirement. • 760A4xxxx does not meet this requirement. IP4 Portable RFID Reader Instructions • The 700 Color must be running one of these operating systems (OS): • 4.95.1 or later Prem (Premium) • 4.96.4 or later GSM Phone • If the fourth character in the configuration number (CN) of your IP4 is an “A”: • The 700 Color must be running IVA 4.03.35.1043 or later. • Your IP4 must be running firmware version 5.19 or later. • If the fourth character in the configuration number (CN) of your IP4 is an “B”: • The 700 Color must be running IVA 4.03.35.1050 or later. • Your IP4 must be running firmware version 7.16 or later. Note: Use Intermec Settings to find the OS and IVA versions of the 700 Color. For help, see the user’s manual for the 700 Color. To configure your IP4 as a keyboard wedge 1 Fully charge your IP4 battery and attach your IP4 to a 700 Color. 2 On the 700 Color, start Intermec Settings. 3 Select RFID > Reader 1, and select Enable Reader. 4 Under Reader 1, select Reader Module > Tag Type, and select the type of RFID tag you are using. 5 From the main Intermec Settings menu, select Device Settings > Keypad > Scan Button Remapping > Handle Trigger, and select RFID. 6 Save your settings. edit for correct terminal config no cell phone offering in CK61 options limited for CN3 NO CDMA or GPRS radio IP4 Portable RFID Reader Instructions RF safe distance may need correction. To test the keyboard wedge 1 Start Microsoft Pocket Word. 2 Read an RFID tag. For help, see the next section. The RFID tag information appears in Pocket Word. initial distance repl 20 cm (8 in) with 23 cm (9 in) TBD Reading an RFID Tag You can scan at least six RFID tags per second with the IP4. Note: Continuously reading tags with the IP4 may cause the IP4 to overheat. If the IP4 temperature rises above the maximum operating temperature, the IP4 will stop reading tags. If this occurs, let the IP4 cool down until its temperature is within the operating temperature range. RF Exposure regulations limit exposure to radio frequency (RF) radiation. To comply with these regulations, operators of this device must maintain a distance of at least 20 cm (8 in) from the cover on the antenna assembly. (The cover on the antenna is the dome-shaped surface.) While the device is on, the operator’s body and parts of the body such as eyes, hands, or head, must be 20 cm (8 in) or farther from the cover of the antenna assembly. Avertissement: Les réglementations sur les expositions RF limitent l'exposition aux rayonnements RF. Pour se conformer à ces réglementations, les opérateurs de ce dispositif doivent maintenir une distance minimale de 20 cm du couvercle de l'antenne. (Le couvercle de l'antenne est la surface bombée.) Lorsque l'appareil est sous tension, le corps et les parties du corps (yeux, mains, tête) de l'opérateur doivent être à au moins 20 cm du couvercle de l'antenne. To read an RFID tag 1 Position the front of the IP4 within 91 cm (3 ft) of an RFID tag. 2 Pull the trigger. IP4 Portable RFID Reader Instructions Understanding the IP4 LEDs Your IP4 uses LEDs to indicate the status of certain operations. LEDs IP4 LEDs: The IP4 LEDs are located on the back of the IP4. IP4 LED Descriptions Icon LED Power (PWR) Description This LED is green when +5 power is on and the IP4 is ready to read tags. Host Communications This LED is green when data (HOST COMM) communication with the host is active. RF Power On (RF ON) This LED is green when RF power is on. Tag Communications (TAG COMM) This LED turns green after the IP4 successfully reads an RFID tag. Battery (BATT) This LED indicates the status of the battery: • Red: The battery is low (less than 20% capacity). • Green: The battery is fully charged (more than 80% capacity). • Orange: The battery is charged (from 20% to 80% capacity). replace with IP30 placements IP4 Portable RFID Reader Instructions Specifications This section contains specifications for the IP4. Environmental Specifications Specification Value Operating temperature 0°C to 50°C (32°F to 122°F) Storage temperature -30°C to 70°C (-22°F to 158°F) Relative humidity 5 to 95% non-condensing 869 MHz Frequency Specification Value Source type Single Channel Frequency band 869.525 MHz EIRP/ERP 0.5 watt ERP Output power 1 W maximum Minimum = 26.0 dBm Typical = 26.5 dBm Maximum = 27.0 dBm Modulation 80% Data Rate N/A 915 MHz Frequency Specification Value Source type Frequency hopper Frequency band 902-928 MHz EIRP/ERP 1 watt EIRP Output power 1 W maximum Minimum = 28.5 dBm Typical = 29.5 dBm Maximum = 30.0 dBm Modulation 90% Data Rate 38 to 44 Kbps 10 IP4 Portable RFID Reader Instructions Performance Specification Value RFID tag identification At least six tags per second with one to ten rate tags in the RF field, located at half the maximum reading distances from the IP4 front panel. RFID tag read distance 91 cm (3 ft) RFID tag data exchange rates Read a tag containing 8 bytes of data within 50 ms. Perform a verified write to tag at an average rate of 75 ms per byte per tag. Firmware Architecture Specification Description Firmware Communicates in Basic Reader Interface (BRI) mode. Protocol/Compatibility ANSI NCITS 256.2000 for API, part 2, part 3-1 Reader Configuration Access Summary Function Control Mechanism Responsible Party Change Country Code Hardware key or configuration tag Factory or Intermec® Field Technician Download updated firmware Intermec-only password Remote or on-site field technician Configuration file Setup, system configuration not secured at higher level, such as change battery or wake up default IP4 Portable RFID Reader Instructions Customer System Administrator 11 Patent Information Product is covered by one or more of the following patents: 5,673,037; 5,729,697; 5,777,561; 5,828,318; 5,850,187; 5,912,632; 5,942,987; 5,995,019; 6,032,127; 6,121,878; 6,172,596; 6,286,762; 6,288,629; 6,422,476; 6,429,775; 6,525,648; 6,529,880; 6,608,551; 6,639,509; 6,812,841; 6,812,852; 6,919,793. Patent Application 2002-0046173. There may be other U.S. and foreign patents pending. Worldwide Headquarters 6001 36th Avenue West Everett, Washington 98203 U.S.A. tel 425.348.2600 fax 425.355.9551 www.intermec.com © 2007 Intermec Technologies Corporation. All rights reserved. IP4 Portable RFID Reader Instructions *943-002-004* P/N 943-002-004
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Page Count : 12 Page Mode : UseOutlines Page Layout : SinglePage Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:612fded7-3b04-4f75-af8c-3da9e06bafab Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : FrameMaker 7.1 Modify Date : 2008:02:28 17:30:24-06:00 Create Date : 2007:10:26 11:40:07Z Metadata Date : 2008:02:28 17:30:24-06:00 Document ID : uuid:160c5f28-63ad-43ea-b352-fa6e15f9506b Instance ID : uuid:73c737d5-a5a1-470c-8849-095a40fda944 Format : application/pdf Title : 943-002.book Creator : tdavis Author : tdavisEXIF Metadata provided by EXIF.tools