Intermec Technologies 700C-SMC45-1 Notepad Computer with 3 Radio Lans User Manual back let85x11

Intermec Technologies Corporation Notepad Computer with 3 Radio Lans back let85x11

User Manual

Download: Intermec Technologies 700C-SMC45-1 Notepad Computer with 3 Radio Lans User Manual back let85x11
Mirror Download [FCC.gov]Intermec Technologies 700C-SMC45-1 Notepad Computer with 3 Radio Lans User Manual back let85x11
Document ID323292
Application IDAKcxxypA4qMkMX9gcMWDMg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize297.08kB (3713556 bits)
Date Submitted2003-05-06 00:00:00
Date Available2004-02-05 00:00:00
Creation Date2002-12-14 00:15:06
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2003-01-13 10:11:36
Document Titleback_let85x11
Document CreatorADOBEPS4.DRV Version 4.53
Document Author: thinga

User’s Manual
700 Series Color
Mobile Computer
User’s Manual
700 Series Color
Mobile Computer
S NOTICE
The information contained herein is proprietary and is provided solely for the purpose of allowing
customers to operate and service Intermec manufactured equipment and is not to be released,
reproduced, or used for any other purpose without written permission of Intermec.
Disclaimer of Warranties. The sample source code included in this document is presented for
reference only. The code does not necessarily represent complete, tested programs. The code is
provided “AS IS WITH ALL FAULTS.” ALL WARRANTIES ARE EXPRESSLY
DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE.
We welcome your comments concerning this publication. Although every effort has been made to
keep it free of errors, some may occur. When reporting a specific problem, please describe it
briefly and include the book title and part number, as well as the paragraph or figure number and
the page number.
Send your comments to:
Intermec Technologies Corporation
Publications Department
550 Second Street SE
Cedar Rapids, IA 52401
ANTARES, INTERMEC, NORAND, NOR*WARE, PEN*KEY, ROUTEPOWER,
TRAKKER, and TRAKKER ANTARES are registered trademarks and ArciTech, ENTERPRISE
WIRELESS LAN, i-gistics, INCA, Mobile Framework, MobileLAN, TE 2000, UAP, and
UNIVERSAL ACCESS POINT are trademarks of Intermec Technologies Corporation.

2002 Intermec Technologies Corporation. All rights reserved.
Acknowledgments
ActiveSync, ActiveX, Microsoft, MS, MS-DOS, Outlook, Pocket Outlook, Pocket PC, Windows,
Windows NT, and the Windows logo are registered trademarks and MSDN, SQL Server, Visual
Basic, Visual C++, and Windows for Pen are trademarks of Microsoft Corporation in the United
States and/or other countries. Microsoft products are licensed to OEMs by Microsoft Licensing,
Inc., a wholly owned subsidiary of Microsoft Corporation.
Bluetooth is a trademark of Bluetooth SIG, Inc., U.S.A.
CDMA2000 is a trademark of the Telecommunications Industry Association (TIA).
GSM is a registered trademark of the GSM Association.
Microclean II is a registered trademark of Foresight International.
MultiMediaCard is a trademark of Infineon Technologies AG, Germany, and is licensed to
MMCA (MultiMediaCard Association).
SanDisk is a trademark of SanDisk Corporation.
Siemens is a registered trademark of Siemens AG. Siemens product names are either trademarks or
registered trademarks of Siemens or Siemens AG.
Sprint is a registered trademark of Sprint Communications Company L.P.
This product includes software developed by the OpenSSL Project for use in the OpenSSL
Toolkit. (http://www.openssl.org/)
This product includes cryptographic software written by Eric Young (eay@cryptsoft.com)
ii
Contents
Contents
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Safety Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Warnings, Cautions, and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
Format Conventions for Input From a Keyboard or Keypad . . . . . . . . . . . . . . . . . . . . . . xvii
Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii
Global Services and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii
Web Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii
Introduction
About the 700 Series Color Mobile Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Audio System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Speaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Microphone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
External Headset Jack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low Battery Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Status Maintained . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAB Files Within 700C Software Tools CD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modem Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Network Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removeable Card Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CompactFlash Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SecureDigital Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MultiMediaCards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Software Build Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What’ s New . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
700 Series Color Mobile Computer User’s Manual
iii
Contents
Pocket PC 2002
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Premium versus Professional Editions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Where to Find Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Basic Skills . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Buttons and Stylus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Today Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Navigation Bar and Command Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pop-up Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enter Information on Your 700 Series Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typing With the Soft Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Block Recognizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Letter Recognizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Transcriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selecting Typed Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Writing on the Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selecting the Writing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Converting Writing to Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drawing on the Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selecting a Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recording a Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using My Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Finding and Organizing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Customizing Your 700 Series Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjusting Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adding or Removing Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
11
11
13
14
15
15
16
17
17
18
18
18
19
19
20
22
22
22
23
23
24
25
26
26
26
Microsoft ActiveSync . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Microsoft Pocket Outlook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Calendar: Scheduling Appointments and Meetings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating an Appointment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Summary Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating Meeting Requests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scheduling a Meeting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contacts: Tracking Friends and Colleagues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Finding a Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Summary Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tasks: Keeping a To Do List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Task . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Summary Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes: Capturing Thoughts and Ideas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Note . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iv
31
31
32
33
33
33
34
34
35
36
37
38
39
40
41
700 Series Color Mobile Computer User’s Manual
Contents
Inbox: Sending and Receiving E-mail Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Synchronizing E-mail Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting Directly to an E-mail Server . . . . . . . . . . . . . . . . . . . . . . . .
Using the Message List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Composing Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Managing E-mail Messages and Folders . . . . . . . . . . . . . . . . . . . . . . . . .
Folder Behavior With a Direct Connection to an E-mail Server . . . . . . .
42
42
42
43
45
46
46
Companion Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pocket Word . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typing Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Writing Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drawing Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recording Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pocket Excel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Workbook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tips for Working in Pocket Excel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MSN Messenger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Working with Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chatting with Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Windows Media Player for Pocket PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Microsoft Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Getting Books on Your 700 Series Computer . . . . . . . . . . . . . . . . . . . . .
Using the Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reading a Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Reader Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing a Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
47
47
47
49
50
51
51
52
52
53
53
54
54
55
57
58
58
59
60
61
61
Pocket Internet Explorer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The Mobile Favorites Folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Favorite Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mobile Favorites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using AvantGo Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Pocket Internet Explorer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viewing Mobile Favorites and Channels . . . . . . . . . . . . . . . . . . . . . . . .
Browsing the Internet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
62
62
62
62
64
65
66
66
Getting Connected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transferring Items Using Infrared . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sending Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receiving Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to an Internet Service Provider . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Modem Connection to an ISP . . . . . . . . . . . . . . . . . . . . . . .
Creating an Ethernet Connection to an ISP . . . . . . . . . . . . . . . . . . . . . .
Connecting to Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Modem Connection to Work . . . . . . . . . . . . . . . . . . . . . . . .
Creating an Ethernet Connection to Work . . . . . . . . . . . . . . . . . . . . . . .
Ending a Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting Directly to an E-mail Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting Up an E-mail Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
67
67
67
67
68
68
69
70
70
71
72
72
73
700 Series Color Mobile Computer User’s Manual
Contents
Installing Applications
Packaging an Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Installing Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Microsoft ActiveSync . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the FTP Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Application Manager in Unit Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using a Storage Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Copying to a CompactFlash Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Copying to a SecureDigital Storage Card . . . . . . . . . . . . . . . . . . . . . . . .
76
77
78
78
78
78
79
Updating the System Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Application Migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Cabinet File Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Network Support
CORE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Network Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Ethernet Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
802.11b Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Import/Export . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Scan List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Network Selection APIs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Function Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
802.11b Radio CORE Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
WWAN Radio Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
GSM/GPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
CDMA/1xRTT SB555 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
WAN Radio CORE Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
AT Command Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Wireless Printing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Bluealps CORE Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
AutoIP/DHCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
SNMP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The Focus was “Simple” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Retrieval of Management Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
An Early Approach to Getting More than One Item at a Time . . . . . . . . . . . . . . . . . . .
Conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SNMP Configuration on the 700 Series Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Management Information Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Object Identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring with SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi
123
123
123
124
124
124
125
125
126
126
700 Series Color Mobile Computer User’s Manual
Contents
Printer Support
Printing ASCII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Directly to a Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Directly to a Generic Serial Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
IrDA Printer Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
NPCP Printer Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
About NPCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NPCP Driver Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Opening the NPCP Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Closing the NPCP Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reading from the NPCP Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Writing to the NPCP Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NPCP Driver I/O Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NPCP Printer Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sample Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NPCP Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
129
129
129
130
130
130
130
131
132
132
133
O’ Neil Printer Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTR Driver Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Opening the DTR Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Closing the DTR Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Writing to the DTR Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTR Printer Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
134
134
135
135
135
135
Scanner Support
Scanner Control and Data Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Automatic Data Collection COM Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multiple ADC COM Object Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to Create and Use the ADC COM Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read-Ahead Bar Code Data Access . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Grid Data Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Filter Expression Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Editing Expression Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2D Imager Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Data Collection Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Image Acquisition Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Create and Delete ADC COM Object Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ITCDeviceOpen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ITCDeviceClose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
700 Series Color Mobile Computer User’s Manual
138
139
140
140
141
142
144
145
146
146
147
149
149
150
vii
Contents
IADC Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IADC::CancelReadRequest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IADC::Initialize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IADC::QueryAttribute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IADC::QueryData . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IADC::Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IADC::SetAttribute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IBarCodeReaderControl Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IBarCodeReaderControl::CancelReadRequest . . . . . . . . . . . . . . . . . . .
IBarCodeReaderControl::ControlLED . . . . . . . . . . . . . . . . . . . . . . . . .
IBarCodeReaderControl::Initialize . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IBarCodeReaderControl::IssueBeep . . . . . . . . . . . . . . . . . . . . . . . . . . .
IBarCodeReaderControl::QueryAttribute . . . . . . . . . . . . . . . . . . . . . . .
IBarCodeReaderControl::Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IBarCodeReaderControl::SetAttribute . . . . . . . . . . . . . . . . . . . . . . . . .
IBarCodeReaderControl::TriggerScanner . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetCodabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetCodabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Codabar Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Codabar Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetCode39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetCode39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 39 Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 39 Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetCode93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetCode93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 93 Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 93 Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetCode128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetCode128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 128/EAN 128 Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 128 Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetI2of5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetI2of5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interleaved 2 of 5 Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interleaved 2 of 5 Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetMatrix2of5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetMatrix2of5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Matrix 2 of 5 Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Matrix 2 of 5 Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetMSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetMSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MSI Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MSI Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetPDF417 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetPDF417 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PDF 417 Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PDF 417 Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetPlessey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetPlessey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plessey Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plessey Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetStandard2of5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetStandard2of5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
viii
151
152
153
154
155
156
157
159
160
161
162
163
164
165
167
171
172
173
174
175
175
176
177
177
178
179
179
179
180
180
181
181
182
183
184
184
185
185
186
186
186
187
187
187
188
188
189
190
190
192
192
193
193
194
195
700 Series Color Mobile Computer User’s Manual
Contents
Standard 2 of 5 Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard 2 of 5 Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetTelepen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetTelepen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Telepen Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Telepen Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::GetUpcEan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig::SetUpcEan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UPC/EAN Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UPC/EAN Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2::GetCode11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2::SetCode11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 11 Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 11 Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2::GetCustomSymIds . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2::SetCustomSymIds . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Custom Identifier Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Custom Identifier Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Custom Identifier Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2::GetGlobalAmble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2::SetGlobalAmble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Postamble and Preamble Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2::GetPDF417Ext . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2::SetPDF417Ext . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PDF 417 Extended: Micro PDF 417 Default Settings . . . . . . . . . . . . .
IS9CConfig2::GetSymIdXmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig2::SetSymIdXmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbology ID Transmission Option . . . . . . . . . . . . . . . . . . . . . . . . . .
IS9CConfig3 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ISCP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ISCP::GetConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ISCP::SetConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AIM Symbology ID Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
196
196
197
197
197
198
198
200
201
201
204
205
205
206
206
207
208
209
210
210
211
212
212
213
213
214
214
214
215
216
216
217
218
219
IImage Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IImage::ReadSigCapBuffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IImage::ReadSigCapFile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IImage::ReadImage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IImage::CancelReadImage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IImage::Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IImage::Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IImage::Open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IImage::Close . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
221
221
224
225
226
226
227
227
228
Data Collection Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
700 Series Color Mobile Computer User’s Manual
ix
Contents
Tethered Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enabling and Disabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Changing Comm Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tethered Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sabre 1551E or 1553 Tethered Scanner . . . . . . . . . . . . . . . . . . . . . . . .
Welch Allyn 1470 Imager Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Error Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scanner Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Limitations and Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
230
230
231
231
232
232
232
232
233
Programming
Creating CAB Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating Device-Specific CAB Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating an .INF File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sample .INF File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Installation Functions in SETUP.DLL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
After the CAB File Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating CAB Files with CAB Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting the CAB Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
236
236
236
245
248
248
249
250
FTP Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configurable Parameters Via the Registry Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BlockSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DeviceName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DeviceURL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IDNATarget . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ManifestName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PauseAtStartup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Root . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transferring Files Over TCP/IP Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stopping the FTP Server from Your Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Autostart FTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
251
252
252
253
253
254
254
255
255
256
260
260
Full Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
Kernel I/O Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_GET_DEVICE_INFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_ITC_READ_PARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_ITC_WRITE_SYSPARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_GET_DEVICEID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_GET_OAL_VERINFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_GET_BOOTLOADER_VERINFO . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_WARMBOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_COLDBOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_GET_RESET_INFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_GET_BOOT_DEVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_REBOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_PROCESSOR_INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_GET_CPU_ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
264
264
265
270
272
273
274
275
275
276
277
278
279
280
700 Series Color Mobile Computer User’s Manual
Contents
Reboot Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_REBOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_COLDBOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IOCTL_HAL_WARMBOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
280
280
280
280
Remapping the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unshifted Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gold Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alpha Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Key Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How Key Values Are Stored in Registry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Change Notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Advanced Keypad Remapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scan Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sample View of Registry Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
281
281
281
281
282
282
283
283
283
284
Control Panel Applets
Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286
Changing a Parameter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286
About Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
Data Collection Control Panel Applet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UPC/EAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plessey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PDF 417 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Matrix 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Telepen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
QR Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Data Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbology Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbology ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Beeper/LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Beeper Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Beeper Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Good Read Beeps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Good Read Beep Duration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Imager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Aimer LED duration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Image Dimension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
700 Series Color Mobile Computer User’s Manual
288
289
290
291
292
293
294
295
298
299
300
303
304
305
306
307
308
309
309
315
316
317
318
320
321
322
323
323
324
xi
Contents
Virtual Wedge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Virtual Wedge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preamble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Postamble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
325
325
326
327
328
329
SNMP Control Panel Applet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read Only Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read/Write Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read Encryption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write Encryption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Encryption Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
330
331
331
332
333
334
335
336
336
337
338
338
339
340
Unit Information Control Panel Applet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Battery Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAB Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
341
342
343
344
Unit Manager
Data Collection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbology ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Beeper/LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Imager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Virtual Wedge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
348
348
349
349
350
350
SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
350
350
351
351
Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Date/Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Backlight Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Key Clicks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Automatic Shutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
352
352
353
354
355
356
Using Reader Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
Change Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
Set Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358
xii
700 Series Color Mobile Computer User’s Manual
Contents
Bar Codes
Bar Code Symbologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Encoded Code 39 (Concatenation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Encoded Code 39 (Full ASCII) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I 2 of 5 (Interleaved) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S 2 of 5 (Standard 2 of 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plessey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MSI Code (Variant of Plessey) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
360
362
362
362
363
363
363
363
364
364
366
366
367
367
Bar Code Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Audio Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Automatic Shutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Backlight Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Key Clicks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Virtual Wedge Grid, Preamble, Postamble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preamble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Postamble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
368
368
369
369
370
371
371
371
371
Index
Classes and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
General Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
Files Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398
700 Series Color Mobile Computer User’s Manual
xiii
Contents
xiv
700 Series Color Mobile Computer User’s Manual
Before You Begin
Before You Begin
This section introduces you to standard warranty provisions, safety
precautions, warnings and cautions, document formatting conventions,
and sources of additional product information. A documentation roadmap
is also provided to guide you in finding the appropriate information.
Warranty Information
To receive a copy of the standard warranty provision for this product, contact your local Intermec support services organization. In the U.S. call
1-800-755-5505, and in Canada call 1-800-668-7043. If you live outside
of the U.S. or Canada, you can find your local Intermec support services
organization on the Intermec Web site at www.intermec.com.
Note: Opening this product may void the warranty. The internal workings
of this product can only be accessed by Intermec service personnel. Radio
replacements and upgrades require Intermec service personnel.
Safety Summary
Your safety is extremely important. Follow these guidelines:
S Read and follow all warnings and cautions in this book before handling
and operating Intermec equipment. You can be seriously injured, and
equipment and data can be damaged if you do no follow the safety
warnings and cautions.
S Do not repair or adjust energized equipment alone under any circumstances. Someone capable of providing first aid must always be present
for your safety.
S Always obtain first aid or medical attention immediately after an injury.
Never neglect an injury, no matter how slight it seems.
S Begin resuscitation immediately if someone is injured and stops breathing. Any delay could result in death. To work on or near high voltage,
you should be familiar with approved industrial first aid methods.
S Never work on energized equipment unless authorized by a responsible
authority. Energized electrical equipment is dangerous. Electrical shock
from energized equipment can cause death. If you must perform authorized emergency work on energized equipment, be sure that you comply
strictly with approved safety regulations.
700 Series Color Mobile Computer User’s Manual
xv
Before You Begin
Warnings, Cautions, and Notes
The warnings, cautions, and notes in this manual use this format:
A warning alerts you of an operating procedure, practice, condition, or
statement that must be strictly observed to avoid death or serious injury
to the persons working on the equipment.
Attention Danger: Un avertissement vous avertit d’une procédure de
fonctionnement, d’une méthode, d’un état ou d’un rapport qui doit être
strictement respecté pour éviter l’occurrence de mort ou de blessures
graves aux personnes manupulant l’équipement.
A caution alerts you to an operating procedure, practice, condition, or
statement that must be strictly observed to prevent equipment damage or
destruction, or corruption or loss of data.
Attention: Une précaution vous avertit d’une procédure de
fonctionnement, d’une méthode, d’un état ou d’un rapport qui doit être
strictement respecté pour empêcher l’endommagement ou la destruction
de l’équipement, ou l’altération ou la perte de données.
Note: Notes are statements that either provide extra information about a
topic or contain special instructions for handling a particular condition or
set of circumstances.
About This Manual
The 700 Series Color Mobile Computer User’ s Manual provides you with
information about the features of the 700 Series Color Mobile Computer
and how to configure, troubleshoot, and support it. You must be familiar
with your host PC, your network, and your other Intermec equipment.
S Chapter 1 — Introduction
Introduces the 700 Series Color Mobile Computer.
S Chapter 2 — Pocket PC 2002
Introduces the Pocket PC 2002 operating system from Microsoft Corporation, and explains how to use its Outlook, ActiveSync, Internet Explorer, and other companion programs.
S Chapter 3 — Installing Applications
Provides methods to install applications and CAB files, also covers application migration.
S Chapter 4 — Network Support
Introduces the CORE application, network adapters such as Ethernet,
802.11b radios, GSM/GPRS or CDMA/1xRTT embedded radio modules, and wireless printing equipped with a Bluetooth module, SNMP
configuration, and Network Selection APIs.
S Chapter 5 — Printer Support
Provides information on printing ASCII to either a port or to a generic
serial port, and on working with IrDA, NPCP, and O’ Neil printer drivers.
xvi
700 Series Color Mobile Computer User’s Manual
Before You Begin
S Chapter 6 — Scanner Support
Provides Automatic Data Collection COM and IImage interfaces and
lists settings via Data Collection parameters.
S Chapter 7 — Programming
Programming information that includes creating CAB files, the FTP
Server, Full Screen, Kernel I/O Control Functions, Reboot Functions,
and remapping the keypad.
S Appendix A — Control Panel Applets
Contains detailed information about the Data Collection, SNMP, and
Unit Information control panel applets.
S Appendix B — Unit Manager
Describes how to configure some parameters via the Unit Manager application and includes reader commands.
S Appendix C — Bar Codes
Describes some of the more common bar code symbologies and includes
bar code labels that can be scanned to configure your 700 Series Computer.
Format Conventions for Input From a Keyboard or Keypad
This table describes the formatting conventions for input from PC or host
computer keyboards and device keypads.
Format Conventions
Convention
Description
Special text
Shows the command as you should enter it into the device.
Italic text
Indicates a variable that you must replace the parameter with a value.
Bold text
Indicates the keys you must press on a PC or host computer keyboard. For example, “press Enter” means you press the key labeled
“Enter” on the PC or host computer keyboard.
where
This word introduces a list of parameters and explains the values you
can specify for them.
700 Series Color Mobile Computer User’s Manual
xvii
Before You Begin
Related Publications
To order printed versions of the Intermec manuals, contact your local Intermec representative or distributor. Following are related Intermec
manuals, CD-ROMs, and part numbers (P/N). For other versions and
languages, consult your Intermec sales representative.
S 700 Series Color Mobile Computer Quick Start Guide
(P/N: 962-054-053)
S 700 Color Recovery CD PPC 2002 Professional Edition WWE
(P/N: 235-100-001 Kit)
S 700 Color Recovery CD PPC 2002 Premium Edition WWE
(P/N: 235-101-001 Kit)
S 700 Series Color Software Tools CD (P/N: 235-099-001)
S Windows 95 and Windows CE Configuration Utilities Reference Manual
(P/N: 978-054-010)
Global Services and Support
Select any of the following services available from Intermec Technologies
Corporation:
S Factory Repair and On-site Repair
To request a return authorization number for one of our authorized service centers, or to request an on-site repair technician, call
1-800-755-5505, then select option 1.
S Technical Support
For technical support on your Intermec product, call 1-800-755-5505,
then select option 2.
S Service Contract Status
To inquire about an existing contract, or to renew a contract, call
1-800-755-5505, then select option 3.
S Schedule Site Surveys or Installations
To schedule a site survey, or to request a product or system installation,
call 1-800-755-5505, then select option 4.
Web Support
Visit our Web site at http://www.intermec.com to download many of our
current manuals in PDF format.
Visit our technical knowledge base (Knowledge Central) at
http://intermec.custhelp.com to review technical information or to request
technical help for all Intermec products.
xviii
700 Series Color Mobile Computer User’s Manual
1
Introduction
This chapter introduces the 700 Series Color (700C) Mobile Computer,
developed by Intermec Technologies Corporation to enhance wireless connectivity needs.
700 Series Color Mobile Computer User’s Manual
Chapter 1 — Introduction
About the 700 Series Color Mobile Computer
Audio System
Speaker
A speaker capable of variable volume levels is located on the back of the
computer. This speaker has a transducer volume of 85 dB min at 10 CM
and a frequency range of 1-8 KHz.
Internal Microphone
The internal microphone is located on the bottom of the unit to the left of
the hirose connector.
External Headset Jack
The external headset jack connects a mono headset to your mobile computer for use in noisy environments. The jack is a 2.5 mm, three-conductor jack, with autosensing of the headset jack insertion which disables the
internal speaker and microphone. The external headset jack is located on
the bottom of the mobile computer to the right of the hirose connector.
Battery
The 700 Series Computer comes equipped with a nominal 14.4
Watt-hour, 7.2V (two 2000 mAh cells), replaceable Lithium-Ion (LiIon)
battery. To view the status of this battery from the 700 Series Computer,
tap Start → Settings → the System tab → the Power icon to view the
current status of both the main battery and the backup battery. Tap ok to
exit this information.
700 Series Color Mobile Computer User’s Manual
Chapter 1 — Introduction
Note: The Unit Information control panel applet is only available in the
700 Series Computer if Intermec Content is enabled, the Plus region is
enabled and installed, and a laser scanner is installed.
You can also view the battery status for the 700 Series Computer by
accessing the Unit Information control panel applet. Tap the Unit
Information icon, then tap the Battery Status tab to view the current
status. Tap ok to exit this information.
Low Battery Shutdown
If your computer shuts down because of low battery conditions, your computer will not operate. This is done to ensure that data is protected. Although the battery will protect the data against loss for several hours, you
should connect your computer to a power source when you first detect a
low battery condition.
Your computer contains an internal super capacitor, a temporary power
storage device, that protects data for up to ten minutes. This is to give you
time to replace the main battery pack before that data is lost. Be sure to put
the computer in a suspend mode before doing so.
The battery power fail level is set so that after the system shuts down in a
low battery condition, there is still sufficient charge to allow the unit to
remain configured, keep proper time, and maintain DRAM (Dynamic
Random Access Memory) for at least 72 hours at room temperature if the
main battery remains in the mobile computer. The configuration and time
are lost if:
S The battery discharges beyond this level.
S The battery is removed when the computer is not in suspend mode.
S A cold reset is performed on the computer.
700 Series Color Mobile Computer User’s Manual
Chapter 1 — Introduction
System Status Maintained
System status is maintained in “suspend” when the main battery is removed:
S 10 minutes for 64 MB low-power chips
S 5 minutes for 128 MB low-power chips
CAB Files Within 700C Software Tools CD
If you leave the default destination while you install the “\700 Color
Mgmt Tools” directory onto your desktop PC, then “C:\Intermec\Intermec 700 Color Mgmt Tools\Cab Files” will be the default directory. There
are folders within the “\Cab Files” directory that contain demos and program files. See the 700 Series Color Software Tools CD User’ s Manual for
more information about these files.
Modem Support
Modem PC Cards are not supported by the 700 Series Computer. However, modem options do include the following:
S Switchable dock that includes a built-in modem and a serial port between which an application can switch.
S Mini-Landline Modem that can be tethered to the port on the bottom
of the 700 Series Computer.
S Other external modems that may be connected to the bottom of the
700 Series Computer or to the dock.
Network Support
Radio CompactFlash Cards cannot be installed by a user. The 700 Series
Computer must be serviced to install or replace radios. See Chapter 4,
“Network Support” for more information.
S 802.11b radio
S Integrated GSM/GPRS radio
S CDPM/1xRTT radio
S Wireless printing equipped with a Bluetooth qualified module by Socket
Communications
700 Series Color Mobile Computer User’s Manual
Chapter 1 — Introduction
Removeable Card Support
To access either the CompactFlash (CF) or SecureDigital (SD) card slot,
locate the access door at the top of the 700 Series Computer, remove its
two screws, then remove the door.
CompactFlash Cards
Support is limited to one CompactFlash (CF) Storage Card in the 700 Series Computer, either for storage or for the 802.11b radio.
SecureDigital Cards
Support is limited to one SecureDigital (SD) Storage Card in the 700 Series Computer for storage.
MultiMediaCards
MultiMediaCards (MMCs) are not supported in the 700 Series Computers because current technology shows that SD cards will quickly surpass
MMC cards in storage capacity.
Software Build Version
To check to see if your 700 Series Computer has the latest build, select
Start → Internet Explorer → the Intermec logo.
The latest software build version is displayed beneath the Patent Information title. This information will be useful should you need customer assistance.
Note: The Unit Information control panel applet is only available in the
700 Series Computer if Intermec Content is enabled, the Plus region is
enabled and installed, and a laser scanner is installed.
700 Series Color Mobile Computer User’s Manual
Chapter 1 — Introduction
You can also view the latest software build version on your 700 Series
Computer by accessing the Unit Information control panel applet. Select
Start → Settings → the System tab → the Unit Information icon → the
Versions tab to view the current build version on your 700 Series
Computer.
What’ s New
The newest functionality is available in software build versions 1.30 or
greater. The following changes have occurred since the last release of this
manual:
S Applied new publications standards to this manual.
S Adapted instructions using Ethernet connections to fit Intermec requirements in Chapter 2, “Pocket PC 2002.”
S Moved “Updating System Software” and “EFlash” information to the Recovery CD User’ s Manual from Chapter 3, “Installing Applications.”
S Removed several 802.11 APIs not related to the 700 Series Color Computer from Chapter 4, “Network Support.”
S Added the Siemens MC45 radio module to Chapter 4, “Network Support.”
S Added tethered scanner information to Chapter 6, “Scanner Support.”
S Added CAB extraction information and FTP Server parameters to
Chapter 7, “Programming.”
S Added imager option information via the Data Collection control panel
applet to Appendix A, “Control Panel Applets.” Note that this is for 700
Series Computers using an imager.
700 Series Color Mobile Computer User’s Manual
2
Pocket PC 2002
This chapter introduces the Pocket PC 2002 operating system from
Microsoft Corporation.
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Introduction
Congratulations on purchasing a Pocket PC. Due to the size and capabilities of this 700 Series Color Mobile Computer, you can keep your most
important business and personal information up-to-date and close at hand.
Microsoft ActiveSync increases the power of your 700 Series Computer by
allowing you to synchronize the information on your desktop or laptop
computer with your 700 Series Computer. Picture yourself in the following situations:
S A Calendar reminder alerts you that it is time to catch the bus. You grab
your 700 Color Pocket PC Mobile Computer and catch the bus just in
time. Because ActiveSync keeps the information on your 700 Series
Computer up-to-date, you leisurely review your task list, make notes
about the new books and CDs you want to buy, and read and respond
to e-mail messages. When you get back to the office, ActiveSync transfers any task changes you made, your notes, and your e-mail message
responses to your desktop computer. For more information on ActiveSync, see “Microsoft ActiveSync” on page 29.
S While walking with a colleague, your 700 Color Pocket PC Mobile
Computer rings. You look at the caller ID and see it is your manager
who is calling. She asks if you two are free this afternoon for an emergency meeting. While your colleague fumbles through his paper organizer, you press a button on your 700 Series Computer and instantly see
a list of today’ s appointments and meetings. You are quickly able to tell
your manager your available times, and make a note of the new meeting
while on the call. You hang up, send an e-mail with a schedule request
for the three of you at the desired location. For more information on
scheduling appointments and meetings, see “Microsoft Pocket Outlook”
on page 31.
S You are meeting your friends tonight for dinner and a movie. You
download the latest movie information from the Internet to your desktop computer and then synchronize it with your 700 Series Computer.
At dinner, you pull out your 700 Color Pocket PC Mobile Computer
and review your movie options with your friends. For more information
on downloading Web pages to your 700 Series Computer, see “Pocket
Internet Explorer” on page 62.
Premium versus Professional Editions
Your 700 Series Computer will have either the Premium Edition or the
Professional Edition of Pocket PC 2002. Do the following to determine
which edition of Pocket PC 2002 is on your unit.
1 Select Start → Internet Explorer → the Intermec logo.
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
2 Note the “Software Build” information displayed beneath the Version
Information title.
Note: If you have an older software build, your unit may say either
“PREM” (which indicates the Premium Edition) or “PRO” (which indicates
the Professional Edition).
3 Tap the Close icon in the top right corner to exit the Internet Explorer.
Below is a list of components for each edition of Pocket PC 2002:
Component
Premium Professional
Edition
Edition
Microsoft ActiveSync Client (page 29)
Microsoft Pocket Outlook (page 31)
Pocket Word (page 47)
Pocket Excel (page 52)
MSN Messenger (page 53)
Windows Media Player for Pocket PC (page 57)
RAM
Microsoft Reader (page 58)
RAM
Pocket Internet Explorer (page 62)
Note: Components marked with “RAM” are provided on a Companion
CD for download into RAM rather than burned into Flash ROM.
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Where to Find Information
This chapter describes your 700 Series Computer hardware, provides an
overview of the programs on your 700 Series Computer, and explains how
to connect your 700 Series Computer to a desktop computer, a network,
or the Internet. For instructions on setting up your 700 Series Computer
and installing ActiveSync, see the Quick Start Card. The following is a
guide to more information to assist you use your 700 Series Computer.
For information on:
See this source:
Programs on your mobile computer.
This chapter and mobile computer Help. To view Help,
tap Start → Help.
Additional programs that can be installed on the mobile
computer.
The Pocket PC Companion CD.
Connecting to and synchronizing with a desktop computer.
The Quick Start Card or AutoSync Help on your desktop
computer. To view Help, click Help → Microsoft ActiveSync Help.
Last-minute updates and detailed technical information.
The Read Me files, located in the Microsoft ActiveSync
folder on the desktop computer and on the Pocket PC
Companion CD.
Up-to-date information on your Pocket PC.
http://www.microsoft.com/mobile/pocketpc
Pocket PC and many of the technologies supported by the 700 Series
Computer are not from Intermec Technologies. Many of the utilities and
features on a Pocket PC device come directly from Microsoft without any
modification from Intermec Technologies. There may be certain Microsoft-specific issues that Intermec Technologies would not be able to support, so you will have to contact Microsoft Corporation. Use these URLs
to determine your Microsoft support options:
S http://msdn.microsoft.com/support/
S http://support.microsoft.com/
S news://news.microsoft.com (a free support option)
10
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Basic Skills
Learning to use your 700 Series Computer is easy. This describes the basic
concepts of using and customizing your 700 Series Computer.
Buttons and Stylus
Your 700 Series Computer has hardware buttons that control actions and
scroll functions, and a stylus for selecting items and entering information.
On the 700 Series Computer, the stylus replaces the mouse.
S Tap:
Touch the screen once with the stylus to open items and select options.
S Drag:
Hold the stylus on the screen and drag across the screen to select text
and images. Drag in a list to select multiple items.
S Tap and hold:
Tap and hold the stylus on an item to see a list of actions available for
that item. On the pop-up menu that appears, tap the action to be performed.
Today Screen
When you turn on your 700 Series Computer for the first time each day
(or after four hours of inactivity), you will see the Today screen. You can
also display it by tapping the Start flag (shown left) and then Today. On
the Today screen, you can see at a glance important information for the
day.
700 Series Color Mobile Computer User’s Manual
11
Chapter 2 — Pocket PC 2002
Following are some of the status icons you may see:
Status Icon
Meaning:
Turns all sounds on and off.
Backup battery is low.
Main batteries are charging.
Main batteries are low.
Main batteries are very low.
Main batteries are full.
Connection is active.
Synchronization is beginning or ending.
Synchronization is occurring.
Notification or one or more instant messages received.
Notification of one or more e-mail messages received.
If more notification icons need to be displayed than there is
room to display them, the Notification icon (shown left) will
display. Tap the icon to view all notification icons.
12
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Programs
You can switch from one program to another by selecting it from the Start
menu. (You can customize which programs you see on this menu. For
information, see “Adjusting Settings” on page 26.) To access some
programs, tap Start → Programs, and then the program name.
You can also switch to some programs by pressing a program button. Your
700 Series Computer has one or more program buttons located on the
front or side of the computer. The icons on the buttons identify the programs to which they switch.
Note: Some programs have abbreviated labels for check boxes and dropdown menus. To see the full spelling of an abbreviated label, tap and hold
the stylus on the label. Drag the stylus off the label so that the command is
not carried out.
The following is a partial list of programs that are on your 700 Series
Computer. Look on the Pocket PC Companion CD for additional programs that you can install onto your 700 Series Computer.
ActiveSync
Synchronize information between your 700 Series Computer and desktop
computer.
Calendar
Keep track of your appointments and create meeting requests.
Contacts
Keep track of your friends and colleagues.
Inbox
Send and receive e-mail messages.
Pocket Internet Explorer
Browse Web and WAP (Wireless Application Protocol) sites, and download
new programs and files from the Internet.
Notes
Create handwritten or typed notes, drawings, and recordings.
Tasks
Keep track of your tasks.
Pocket Excel
Create new workbooks or view and edit Excel workbooks created on your
desktop computer.
MSN Messenger
Send and receive instant messages with your MSN Messenger contacts.
Pocket Word
Create new documents or view and edit Word documents created on your
desktop computer.
700 Series Color Mobile Computer User’s Manual
13
Chapter 2 — Pocket PC 2002
Navigation Bar and Command Bar
The navigation bar is located at the top of the screen. It displays the active
program and current time, and allows you to switch to programs and close
screens.
Use the command bar at the bottom of the screen to perform tasks in programs. The command bar includes menu names, buttons, and the Input
Panel button. To create a new item in the current program, tap New. To
see the name of a button, tap and hold the stylus on the button. Drag the
stylus off the button so that the command is not carried out.
14
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Pop-up Menus
With pop-up menus, you can quickly choose an action for an item. For
example, you can use the pop-up menu in the contact list to quickly delete
a contact, make a copy of a contact, or send an e-mail message to a contact. The actions in the pop-up menus vary from program to program. To
access a pop-up menu, tap and hold the stylus on the item name that you
want to perform the action on. When the menu appears, lift the stylus,
and tap the action you want to perform. Or tap anywhere outside the
menu to close the menu without performing an action.
Notifications
Your 700 Series Computer reminds you in a variety of ways when you
have something to do. For example, if you have set up an appointment in
Calendar, a task with a due date in Tasks, or an alarm in Clock, you will be
notified in any of the following ways:
S A message box appears on the screen.
S A sound, which you can specify, is played.
S A light flashes on your 700 Series Computer.
S A vibrator resonates from the 700 Series Computer.
To choose reminder types and sounds for your 700 Series Computer, tap
Start → Settings → the Personal tab → Sounds & Notifications. The
options you choose here apply throughout the 700 Series Computer.
700 Series Color Mobile Computer User’s Manual
15
Chapter 2 — Pocket PC 2002
Enter Information on Your 700 Series Computer
You have several options for entering new information:
S Use the input panel to enter typed text, either by using the soft keyboard or other input method.
S Write directly on the screen.
S Draw pictures on the screen.
S Speak into your 700 Series Computer microphone to record a message.
S Use Microsoft ActiveSync to synchronize or copy information from
your desktop computer to your 700 Series Computer. For more information on ActiveSync, see ActiveSync Help on your desktop computer.
Use the input panel to enter information in any program on your 700
Series Computer. You can either type using the soft keyboard or write
using Block Recognizer, Letter Recognizer, or Transcriber. In either case,
the characters appear as typed text on the screen.
To show or hide the input panel, tap the Input Panel button. Tap the
arrow next to the Input Panel button to see your choices.
16
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
When you use the input panel, your 700 Series Computer anticipates the
word you are typing or writing and displays it above the input panel.
When you tap the displayed word, it is inserted into your text at the
insertion point. The more you use your 700 Series Computer, the more
words it learns to anticipate.
Note: To change word suggestion options, such as the number of words
suggested at one time, tap Start → Settings → the Personal tab → Input
→ the Word Completion tab.
Typing With the Soft Keyboard
1 Tap the arrow next to the Input Panel button, and then Keyboard.
2 On the soft keyboard that is displayed, tap the keys with your stylus.
Using Block Recognizer
With Block Recognizer, you can input character strokes using the stylus
that are similar to those used on other 700 Series Computers.
1 Tap the arrow next to the Input Panel button, then Block Recognizer.
2 Write a letter in the box.
When you write a letter, it is converted to typed text that appears on the
screen. For specific instructions on using Block Recognizer, with Block
Recognizer open, tap the question mark next to the writing area.
700 Series Color Mobile Computer User’s Manual
17
Chapter 2 — Pocket PC 2002
Using Letter Recognizer
With Letter Recognizer, you can write letters using the stylus just as you
would on paper.
1 Tap the arrow next to the Input Panel button, then Letter Recognizer.
2 Write a letter in the box.
When you write a letter, it is converted to typed text that appears on the
screen. For specific instructions on using Letter Recognizer, with Letter
Recognizer open, tap the question mark next to the writing area.
Using Transcriber
With Transcriber, you can write anywhere on the screen using the stylus
just as you would on paper. Unlike Letter Recognizer and Block Recognizer, you can write a sentence or more of information. Then, pause and let
Transcriber change the written characters to typed characters.
1 Tap the arrow next to the Input Panel button, and then Transcriber.
2 Write anywhere on the screen.
For specific instructions on using Transcriber, with Transcriber open, tap
the question mark in the lower right hand corner of the screen.
Selecting Typed Text
If you want to edit or format typed text, you must select it first.
S Drag the stylus across the text you want to select.
You can cut, copy, and paste text by tapping and holding the selected
words and then tapping an editing command on the pop-up menu, or by
tapping the command on the Edit menu.
18
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Writing on the Screen
In any program that accepts writing, such as the Notes program, and in
the Notes tab in Calendar, Contacts, and Tasks, you can use your stylus to
write directly on the screen. Write the way you do on paper. You can edit
and format what you have written and convert the information to text at a
later time.
S Tap the Pen button to switch to writing mode. This action displays lines
on the screen to help you write.
Note: Some programs that accept writing may not have the Pen button.
See the documentation for that program to find out how to switch to writing mode.
Selecting the Writing
If you want to edit or format writing, you must select it first.
1 Tap and hold the stylus next to the text you want to select until the insertion point appears.
2 Without lifting, drag the stylus across the text you want to select.
If you accidentally write on the screen, tap Tools → Undo and try again.
You can also select text by tapping the Pen button to deselect it and then
dragging the stylus across the screen.
You can cut, copy, and paste written text in the same way you work with
typed text: tap and hold the selected words and then tap an editing command on the pop-up menu, or tap the command on the Edit menu.
700 Series Color Mobile Computer User’s Manual
19
Chapter 2 — Pocket PC 2002
Converting Writing to Text
S Tap Tools → Recognize.
If you want to convert only certain words, select them before tapping Recognize on the Tools menu (or tap and hold the selected words and then tap
Recognize on the pop-up menu). If a word is not recognized, it is left as
writing.
20
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
If the conversion is incorrect, you can select different words from a list of
alternates or return to the original writing. To do so, tap and hold the incorrect word (tap one word at a time). On the pop-up menu, tap Alternates. A menu with a list of alternate words appears. Tap the word you want
to use, or tap the writing at the top of the menu to return to the original
writing.
Tips for getting good recognition:
S Write neatly.
S Write on the lines and draw descenders below the line. Write the cross
of the “t” and apostrophes below the top line so that they are not confused with the word above. Write periods and commas above the line.
S For better recognition, try increasing the zoom level to 300% using the
Tools menu.
S Write the letters of a word closely and leave big gaps between words so
that the 700 Series Computer can easily tell where words begin and end.
S Hyphenated words, foreign words that use special characters such as accents, and some punctuation cannot be converted.
S If you add writing to a word to change it (such as changing a “3” to an
“8”) after you attempt to recognize the word, the writing you add will
not be included if you attempt to recognize the writing again.
700 Series Color Mobile Computer User’s Manual
21
Chapter 2 — Pocket PC 2002
Drawing on the Screen
You can draw on the screen in the same way that you write on the screen.
The difference between writing and drawing on the screen is how you select items and how they can be edited. For example, selected drawings can
be resized, while writing cannot.
Creating a Drawing
S Cross three ruled lines on your first stroke. A drawing box appears. Subsequent strokes in or touching the drawing box become part of the drawing. Drawings that do not cross three ruled lines will be treated as
writing.
Note: You may want to change the zoom level so that you can more easily
work on or view your drawing. Tap Tools and then a zoom level.
Selecting a Drawing
If you want to edit or format a drawing, you must select it first.
S Tap and hold the stylus on the drawing until the selection handle appears. To select multiple drawings, deselect the Pen button and then
drag to select the drawings you want.
You can cut, copy, and paste selected drawings by tapping and holding the
selected drawing and then tapping an editing command on the pop-up
menu, or by tapping the command on the Edit menu. To resize a drawing,
make sure the Pen button is not selected, and drag a selection handle.
22
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Recording a Message
In any program where you can write or draw on the screen, you can also
quickly capture thoughts, reminders, and phone numbers by recording a
message. In Calendar, Tasks, and Contacts, you can include a recording in
the Notes tab. In the Notes program, you can create a stand-alone recording or include a recording in a written note. If you want to include the recording in a note, open the note first. In the Inbox program, you can add a
recording to an e-mail message.
Creating a Recording
1 Hold your computer’ s microphone near your mouth or source of
sound.
2 Press and hold the Record hardware button on your 700 Series Computer until you hear a beep.
3 While holding down the Record button, make your recording.
4 To stop recording, release the Record button. Two beeps will sound.
The new recording appears in the note list or as an embedded icon.
Note: You can also make a recording by tapping the Record button on the
Recording toolbar.
To play a recording, tap it in the list or tap its icon in the note.
700 Series Color Mobile Computer User’s Manual
23
Chapter 2 — Pocket PC 2002
Using My Text
When using Inbox or MSN Messenger, use My Text to quickly insert preset or frequently used messages into the text entry area. To insert a message, tap My Text and tap a message.
Note: You can add text after inserting a My Text message before sending
it.
To edit a My Text message, in the Tools menu, tap Edit → My Text Messages. Select the message you wish to edit and make desired changes.
24
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Finding and Organizing Information
The Find feature on your 700 Series Computer helps you quickly locate
information.
Tap Start → Find. Enter the text you want to find, select a data type, and
then tap Go to initiate the search.
Note: To quickly find information that is taking up storage space on your
700 Series Computer, select Larger than 64 KB in Type.
You can also use the File Explorer to find files on your 700 Series Computer and to organize these files into folders. Tap Start → Programs → File
Explorer.
Note: You can move files in File Explorer by tapping and holding the item
you want to move, and then tapping Cut or Copy and Paste on the popup menu.
700 Series Color Mobile Computer User’s Manual
25
Chapter 2 — Pocket PC 2002
Customizing Your 700 Series Computer
You can customize your 700 Series Computer by adjusting settings and
installing additional software.
Adjusting Settings
You can adjust settings to suit the way you work. To see available options,
tap Start → Settings → either the Personal tab or the System tab located at
the bottom of the screen. You might want to adjust the following:
S Clock:
To change the time or to set alarms.
S Menus:
To customize what appears on the Start menu, and to enable a pop-up
menu from the New button.
S Owner Information:
To enter your contact information.
S Password:
To limit access to your 700 Series Computer.
S Power:
To maximize battery life.
S Today:
To customize the look and information displayed on the Today screen.
Adding or Removing Programs
Programs added to your 700 Series Computer at the factory are stored in
ROM (Read Only Memory). You cannot remove this software, and you
will never accidentally lose ROM contents. ROM programs can be updated using special installation programs with a *.XIP extension. All other
programs and data files added to your 700 Series Computer after factory
installation are stored in RAM (Random Access Memory).
You can install any program created for your 700 Series Computer, as long
as your 700 Series Computer has enough memory. The most popular place
to find software for your 700 Series Computer is on the Pocket PC Web
site (http://www.microsoft.com/mobile/pocketpc).
Adding Programs Using ActiveSync
You will need to install the appropriate software for your 700 Series Computer on your desktop computer before installing it on your 700 Series
Computer.
1 Determine your 700 Series Computer and processor type so that you
know which version of the software to install. Tap Start → Settings →
the System tab → About → the Version tab, then make a note of the
information in Processor.
2 Download the program to your desktop computer (or insert the CD or
disk that contains the program into your desktop computer). You may
see a single *.XIP, *.EXE, or *.ZIP file, a SETUP.EXE file, or several
versions of files for different 700 Series Computer types and processors.
Be sure to select the program designed for the Pocket PC and your 700
Series Computer processor type.
26
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
3 Read any installation instructions, Read Me files, or documentation that
comes with the program. Many programs provide special installation
instructions.
4 Connect your 700 Series Computer and desktop computer.
5 Double-click the *.EXE file.
S If the file is an installer, the installation wizard will begin. Follow the
directions on the screen. Once the software has been installed on your
desktop computer, the installer will automatically transfer the software to your 700 Series Computer.
S If the file is not an installer, you will see an error message stating that
the program is valid but it is designed for a different type of computer. You will need to move this file to your 700 Series Computer. If
you cannot find any installation instructions for the program in the
Read Me file or documentation, use ActiveSync Explore to copy the
program file to the Program Files folder on your 700 Series Computer. For more information on copying files using ActiveSync, see ActiveSync Help.
Once installation is complete, tap Start → Programs, and then the program icon to switch to it.
Adding a Program Directly from the Internet
1 Determine your 700 Series Computer and processor type so that you
know which version of the software to install. Tap Start → Settings →
the System tab → About → the Version tab, then make a note of the
information in Processor.
2 Download the program to your 700 Series Computer straight from the
Internet using Pocket Internet Explorer. You may see a single *.XIP,
*.EXE, or *.ZIP file, a SETUP.EXE file, or several versions of files for
different 700 Series Computer types and processors. Be sure to select the
program designed for the Pocket PC and your 700 Series Computer
processor type.
3 Read any installation instructions, Read Me files, or documentation that
comes with the program. Many programs provide installation instructions.
4 Tap the file, such as a *.XIP or *.EXE file. The installation wizard will
begin. Follow the directions on the screen.
700 Series Color Mobile Computer User’s Manual
27
Chapter 2 — Pocket PC 2002
Adding a Program to the Start Menu
Tap Start → Settings → Menus → the Start Menu tab, and then the check
box for the program. If you do not see the program listed, you can either
use File Explorer on the 700 Series Computer to move the program to the
Start Menu folder, or use ActiveSync on the desktop computer to create a
shortcut to the program and place the shortcut in the Start Menu folder.
S Using File Explorer on the 700 Series Computer:
Tap Start → Programs → File Explorer, and locate the program (tap the
folder list, labeled My Documents by default, and then My Device to
see a list of all folders on the 700 Series Computer). Tap and hold the
program and tap Cut on the pop-up menu. Open the Start Menu folder located in the Windows folder, tap and hold a blank area of the window, and tap Paste on the pop-up menu. The program will now appear
on the Start menu. For more information on using File Explorer, see
“Finding and Organizing Information” on page 25.
S Using ActiveSync on the desktop computer:
Use the Explorer in ActiveSync to explore your 700 Series Computer
files and locate the program. Right-click the program, and then click
Create Shortcut. Move the shortcut to the Start Menu folder in the
Windows folder. The shortcut now appears on the Start menu. For
more information, see ActiveSync Help.
Removing Programs
S Tap Start → Settings → the System tab → Remove Programs.
If the program does not appear in the list of installed programs, use File
Explorer on your 700 Series Computer to locate the program, tap and hold
the program, and then tap Delete on the pop-up menu.
28
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Microsoft ActiveSync
Visit the following Microsoft Web site for the latest in updates, technical
information, and samples:
S http://www.microsoft.com/mobile/pocketpc/downloads/activesync.asp
Using Microsoft ActiveSync, you can synchronize the information on your
desktop computer with the information on your 700 Series Computer.
Synchronization compares the data on your 700 Series Computer with
your desktop computer and updates both computers with the most recent
information. For example:
S Keep Pocket Outlook data up-to-date by synchronizing your 700 Series
Computer with Microsoft Outlook data on your desktop computer.
S Synchronize Microsoft Word and Microsoft Excel files between your
700 Series Computer and desktop computer. Your files are automatically
converted to the correct format
Note: By default, ActiveSync does not automatically synchronize all types
of information. Use ActiveSync options to turn synchronization on and off
for specific information types.
With ActiveSync, you can also:
S Back up and restore your 700 Series Computer data.
S Copy (rather than synchronize) files between your 700 Series Computer
and desktop computer.
S Control when synchronization occurs by selecting a synchronization
mode. For example, you can synchronize continually while connected to
your desktop computer or only when you choose the synchronize command.
S Select which information types are synchronized and control how much
data is synchronized. For example, you can choose how many weeks of
past appointments you want synchronized.
Before you begin synchronization, install ActiveSync on your desktop
computer from the Pocket PC Companion CD. For more information on
installing ActiveSync, see your Quick Start card. ActiveSync is already
installed on your 700 Series Computer.
After installation is complete, the ActiveSync Setup Wizard helps you connect your 700 Series Computer to your desktop computer, set up a partnership so you can synchronize information between your 700 Series
Computer and your desktop computer, and customize your synchronization settings. Your first synchronization process will automatically begin
when you finish using the wizard.
After your first synchronization, take a look at Calendar, Contacts, and
Tasks on your 700 Series Computer. You will notice that information you
have stored in Microsoft Outlook on your desktop computer has been
copied to your 700 Series Computer, and you did not have to type a word.
Disconnect your 700 Series Computer from your computer and you are
ready to go!
700 Series Color Mobile Computer User’s Manual
29
Chapter 2 — Pocket PC 2002
Once you have set up ActiveSync and completed the first synchronization
process, you can initiate synchronization from your 700 Series Computer.
To switch to ActiveSync on your 700 Series Computer, tap Start →
ActiveSync. Note that if you have a wireless LAN card, you can
synchronize remotely from your 700 Series Computer.
For information about using ActiveSync on your desktop computer, start
ActiveSync on your desktop computer, and then see ActiveSync Help.
For more information about ActiveSync on your 700 Series Computer,
switch to ActiveSync, then tap Start → Help.
30
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Microsoft Pocket Outlook
Note: The Professional Edition of Microsoft Pocket Outlook does not include a spell checker.
Microsoft Pocket Outlook includes Calendar, Contacts, Tasks, Inbox, and
Notes. You can use these programs individually or together. For example,
e-mail addresses stored in Contacts can be used to address e-mail messages
in Inbox.
Using ActiveSync, you can synchronize information in Microsoft Outlook
or Microsoft Exchange on your desktop computer with your 700 Series
Computer. You can also synchronize this information directly with a
Microsoft Exchange server. Each time you synchronize, ActiveSync
compares the changes you made on your 700 Series Computer and desktop computer or server and updates both computers with the latest information. For information on using ActiveSync, see ActiveSync Help on
the desktop computer.
You can switch to any of these programs by tapping them on the Start
menu.
Calendar: Scheduling Appointments and Meetings
Use Calendar to schedule appointments, including meetings and other
events. You can check your appointments in one of several views (Agenda,
Day, Week, Month, and Year) and easily switch views by using the View
menu.
700 Series Color Mobile Computer User’s Manual
31
Chapter 2 — Pocket PC 2002
Note: You can customize the Calendar display, such as changing the first
day of the week, by tapping Options on the Tools menu.
Creating an Appointment
1 If you are in Day or Week view, tap the desired date and time for the
appointment.
2 Tap New.
3 Using the input panel, enter a description and a location. Tap first to
select the field.
4 If needed, tap the date and time to change them.
5 Enter other desired information. You will need to hide the input panel
to see all available fields.
6 To add notes, tap the Notes tab. You can enter text, draw, or create a
recording. For more information on creating notes, see “Notes: Capturing
Thoughts and Ideas” on page 40.
7 When finished, tap OK to return to the calendar.
Note: If you select Remind me in an appointment, your 700 Series Computer will remind you according to the options set in Start → Settings →
the Personal tab → Sounds & Reminders.
32
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Using the Summary Screen
When you tap an appointment in Calendar, a summary screen is displayed.
To change the appointment, tap Edit.
Creating Meeting Requests
You can use Calendar to set up meetings with users of Outlook or Pocket
Outlook. The meeting request will be created automatically and sent either
when you synchronize Inbox or when you connect to your e-mail server.
Indicate how you want meeting requests sent by tapping Tools →
Options. If you send and receive e-mail messages through ActiveSync,
select ActiveSync.
Scheduling a Meeting
1 Create an appointment.
2 In the appointment details, hide the input panel, and then tap
Attendees.
3 From the list of e-mail addresses you have entered in Contacts, select the
meeting attendees.
The meeting notice is created automatically and placed in the Outbox
folder.
For more information on sending and receiving meeting requests, see Calendar Help and Inbox Help on the 700 Series Computer.
700 Series Color Mobile Computer User’s Manual
33
Chapter 2 — Pocket PC 2002
Contacts: Tracking Friends and Colleagues
Contacts maintains a list of your friends and colleagues so that you can
easily find the information you are looking for, whether you are at home
or on the road. Using the 700 Series Computer infrared (IR) port, you can
quickly share Contacts information with other 700 Series Computer users.
Note: To change the way information is displayed in the list, tap Tools →
Options.
Creating a Contact
1 Tap New.
2 Using the input panel, enter a name and other contact information. You
will need to scroll down to see all available fields.
3 To assign the contact to a category, scroll to and tap Categories and select a category from the list. In the contact list, you can display contacts
by category.
4 To add notes, tap the Notes tab. You can enter text, draw, or create a
recording. For more information on creating notes, see “Notes: Capturing
Thoughts and Ideas” on page 40.
34
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
5 When finished, tap OK to return to the contact list.
Finding a Contact
There are four ways to find a contact:
S In the contact list, enter a contact name in the box under the navigation
bar. To show all contacts again, clear text from the box or tap the button
to the right of the box.
S In the contact list, tap the category list (labeled All Contacts by default)
and select the type of contact that you want displayed. To show all contacts again, select All Contacts. To view a contact not assigned to a category, select None.
S To view the names of companies your contacts work for, in the contact
list, tap View → By Company. The number of contacts that work for
that company will be displayed to the right of the company name.
S Tap Start → Find, enter the contact name, select Contacts for the type,
and then tap Go.
700 Series Color Mobile Computer User’s Manual
35
Chapter 2 — Pocket PC 2002
Using the Summary Screen
When you tap a contact in the contact list, a summary screen is displayed.
To change the contact information, tap Edit.
36
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Tasks: Keeping a To Do List
Use Tasks to keep track of what you have to do.
Note: To change the way information is displayed in the list, tap Tools →
Options.
700 Series Color Mobile Computer User’s Manual
37
Chapter 2 — Pocket PC 2002
Creating a Task
1 Tap New.
2 Using the input panel, enter a description.
3 You can enter a start date and due date or enter other information by
first tapping the field. If the input panel is open, you will need to hide it
to see all available fields.
4 To assign the task to a category, tap Categories and select a category
from the list. In the task list, you can display tasks by category.
5 To add notes, tap the Notes tab. You can enter text, draw, or create a
recording. For more information on creating notes, see “Notes: Capturing
Thoughts and Ideas” on page 40.
6 When finished, tap OK to return to the task list.
Note: To quickly create a task with only a subject, tap Entry Bar on the
Tools menu. Then, tap Tap here to add a new task and enter your task
information.
38
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Using the Summary Screen
When you tap a task in the task list, a summary screen is displayed. To
change the task, tap Edit.
700 Series Color Mobile Computer User’s Manual
39
Chapter 2 — Pocket PC 2002
Notes: Capturing Thoughts and Ideas
Quickly capture thoughts, reminders, ideas, drawings, and phone numbers
with Notes. You can create a written note or a recording. You can also include a recording in a note. If a note is open when you create the recording, it will be included in the note as an icon. If the note list is displayed, it
will be created as a stand-alone recording.
40
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Creating a Note
1 Tap New.
2 Create your note by writing, drawing, typing, and recording. For more
information about using the input panel, writing and drawing on the
screen, and creating recordings, see “Basic Skills” on page 11.
700 Series Color Mobile Computer User’s Manual
41
Chapter 2 — Pocket PC 2002
Inbox: Sending and Receiving E-mail Messages
Use Inbox to send and receive e-mail messages in either of these ways:
S Synchronize e-mail messages with Microsoft Exchange or Microsoft
Outlook on your desktop computer.
S Send and receive e-mail messages by connecting directly to an e-mail
server through an Internet Service Provider (ISP) or a network.
Synchronizing E-mail Messages
E-mail messages can be synchronized as part of the general synchronization
process. You will need to enable Inbox synchronization in ActiveSync. For
information on enabling Inbox synchronization, see ActiveSync Help on the
desktop computer. During synchronization:
S Messages are copied from the mail folders of Exchange or Outlook on
your desktop computer to the ActiveSync folder in Inbox on your 700
Series Computer. By default, you will receive messages from the past
three days only, the first 100 lines of each message, and file attachments
of less than 100 KB in size.
S E-mail messages in the Outbox folder on your 700 Series Computer are
transferred to Exchange or Outlook, and then sent from those programs.
S E-mail messages in subfolders must be selected in ActiveSync on your
desktop computer in order to be transferred.
Connecting Directly to an E-mail Server
In addition to synchronizing e-mail messages with your desktop computer,
you can send and receive e-mail messages by connecting to an e-mail server
using a modem or network card connected to your 700 Series Computer.
You will need to set up a remote connection to a network or an ISP, and a
connection to your e-mail server. For more information, see “Getting Connected” on page 67.
When you connect to the e-mail server, new messages are downloaded to
the 700 Series Computer Inbox folder, messages in the 700 Series Computer Outbox folder are sent, and messages that have been deleted on the
e-mail server are removed from the 700 Series Computer Inbox folder.
Messages that you receive directly from an e-mail server are linked to your
e-mail server rather than your desktop computer. When you delete a message on your 700 Series Computer, it is also deleted from the e-mail server
the next time you connect based on the settings selected in ActiveSync.
You can work online or offline. When working online, you read and respond to messages while connected to the e-mail server. Messages are sent
as soon as you tap Send, which saves space on your 700 Series Computer.
When working offline, once you have downloaded new message headers or
partial messages, you can disconnect from the e-mail server and then decide which messages to download completely. The next time you connect,
Inbox downloads the complete messages you have marked for retrieval and
sends the messages you have composed.
42
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Using the Message List
Messages you receive are displayed in the message list. By default, the most
recently received messages are displayed first in the list.
700 Series Color Mobile Computer User’s Manual
43
Chapter 2 — Pocket PC 2002
When you receive a message, tap it to open it. Unread messages are displayed in bold.
When you connect to your e-mail server or synchronize with your desktop
computer, by default, you will receive messages from the last five days
only, the first 100 lines of each new message, and file attachments of less
than 100 KB in size. The original messages remain on the e-mail server or
your desktop computer.
You can mark the messages that you want to retrieve in full during your
next synchronization or e-mail server connection. In the message list, tap
and hold the message you want to retrieve. On the pop-up menu, tap
Mark for Download. The icons in the Inbox message list give you visual
indications of message status.
You specify your downloading preferences when you set up the service or
select your synchronization options. You can change them at any time:
S Change options for Inbox synchronization using ActiveSync options.
For more information, see ActiveSync Help.
S Change options for direct e-mail server connections in Inbox on your
700 Series Computer. Tap Tools → Options → the Service tab, then
tap the service you want to change. Tap and hold the service and select
Delete to remove a service.
44
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Composing Messages
To compose a message:
1 Tap New.
2 In the To field, enter an e-mail or SMS address of one or more recipients, separating them with a semicolon, or select a name from the contact list by tapping the Address Book button. All e-mail addresses entered in the e-mail fields in Contacts appear in the Address Book.
3 Compose your message. To enter preset or frequently used messages, tap
My Text and select a message.
4 Tap Send when you have finished the message. If you are working offline, the message is moved to the Outbox folder and will be sent the
next time you connect.
If you are sending an SMS message and want to know if it was received,
tap Edit → Options → Request SMS text message delivery notification
before sending the message.
700 Series Color Mobile Computer User’s Manual
45
Chapter 2 — Pocket PC 2002
Managing E-mail Messages and Folders
By default, messages are displayed in one of five folders for each service
you have created: Inbox, Deleted Items, Drafts, Outbox, and Sent Items.
The Deleted Items folder contains messages that have been deleted on the
700 Series Computer. The behavior of the Deleted and Sent Items folders
depends on the options you have chosen. In the message list, tap Tools →
Options → the Message tab, then select your options.
If you want to organize messages into additional folders, tap Tools →
Manage Folders to create new folders. To move a message to another folder, in the message list, tap and hold the message and then tap Move to on
the pop-up menu.
Folder Behavior With a Direct Connection to an E-mail Server
The behavior of the folders you create depends on whether you are using
ActiveSync, SMS, POP3, or IMAP4.
S If you use ActiveSync:
E-mail messages in the Inbox folder in Outlook will automatically be
synchronized with your 700 Series Computer. You can select to synchronize additional folders by designating them for ActiveSync. The
folders you create and the messages you move will then be mirrored on
the server. For example, if you move two messages from the Inbox folder to a folder named Family, and you have designated Family for synchronization, the server creates a copy of the Family folder and copies
the messages into that folder. You can then read the messages while away
from your desktop computer.
S If you use SMS:
Messages are stored in the Inbox folder.
S If you use POP3:
and you move e-mail messages to a folder you created, the link is broken
between the messages on the 700 Series Computer and their copies on
the mail server. The next time you connect, the mail server will see that
the messages are missing from the 700 Series Computer Inbox and delete them from the server. This prevents you from having duplicate copies of a message, but it also means that you will no longer have access to
messages that you move to folders created from anywhere except the
700 Series Computer.
S If you use IMAP4:
The folders you create and the e-mail messages you move are mirrored
on the server. Therefore, messages are available to you anytime you connect to your mail server, whether it is from your 700 Series Computer
or desktop computer. This synchronization of folders occurs whenever
you connect to your mail server, create new folders, or rename/delete
folders when connected.
46
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Companion Programs
The companion programs consist of Microsoft Pocket Word, Microsoft
Pocket Excel, Windows Media Player for Pocket PC, and Microsoft
Reader. To switch to a companion program on your 700 Series Computer,
tap Start → Programs, then tap the program name.
Pocket Word
Pocket Word works with Microsoft Word on your desktop computer to
give you easy access to copies of your documents. You can create new documents on your 700 Series Computer, or you can copy documents from
your desktop computer to your 700 Series Computer. Synchronize documents between your desktop computer and your 700 Series Computer so
that you have the most up-to-date content in both locations.
Creating a Document
Use Pocket Word to create documents, such as letters, meeting minutes,
and trip reports. To create a new file, tap Start → Programs → Pocket
Word → New. A blank document appears. Or, if you have selected a template for new documents in the Options dialog box, that template appears
with appropriate text and formatting already provided. You can open only
one document at a time; when you open a second document, you will be
asked to save the first. You can save a document you create or edit in a variety of formats, including Word (.DOC), Pocket Word (.PSW), Rich Text
Format (.RTF), and Plain Text (.TXT).
700 Series Color Mobile Computer User’s Manual
47
Chapter 2 — Pocket PC 2002
Pocket Word contains a list of the files stored on your 700 Series Computer. Tap a file in the list to open it. To delete, make copies of, and send files,
tap and hold a file in the list. Then, select the appropriate action on the
pop-up menu.
You can enter information in Pocket Word in one of four modes (typing,
writing, drawing, and recording), which are displayed on the View menu.
Each mode has its own toolbar, which you can show and hide by tapping
the Show/Hide Toolbar button on the command bar.
Note: You can change the zoom magnification by tapping View → Zoom,
then select the percentage you want. Select a higher percentage to enter
text and a lower one to see more of your document.
If you are opening a Word document created on a desktop computer, select
Wrap to Window on the View menu so that you can see the entire
document.
48
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Typing Mode
Using the input panel, enter typed text into the document. For more information on entering typed text, see “Basic Skills” on page 11.
To format existing text and to edit text, first select the text. You can select
text as you do in a Word document, using your stylus instead of the mouse
to drag through the text you want to select. You can search a document to
find text by tapping Edit → Find/Replace.
700 Series Color Mobile Computer User’s Manual
49
Chapter 2 — Pocket PC 2002
Writing Mode
In writing mode, use your stylus to write directly on the screen. Ruled
lines are displayed as a guide, and the zoom magnification is greater than
in typing mode to allow you to write more easily. For more information on
writing and selecting writing, see “Basic Skills” on page 11.
Note: If you cross three ruled lines in a single stylus stroke, the writing
becomes a drawing, and can be edited and manipulated as described in
“Drawing Mode” on the next page.
Written words are converted to graphics (metafiles) when a Pocket Word
document is converted to a Word document on your desktop computer.
50
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Drawing Mode
In drawing mode, use your stylus to draw on the screen. Grid lines appear
as a guide. When you lift your stylus off the screen after the first stroke,
you will see a drawing box indicating the boundaries of the drawing. Every
subsequent stroke within or touching the drawing box becomes part of the
drawing. For more information on drawing and selecting drawings, see
“Basic Skills” on page 11.
Recording Mode
In recording mode, embed a recording into your document. Recordings are
saved as .WAV files. For more information on recording, see “Basic Skills”
on page 11.
For more information on using Pocket Word, tap Start → Help.
700 Series Color Mobile Computer User’s Manual
51
Chapter 2 — Pocket PC 2002
Pocket Excel
Pocket Excel works with Microsoft Excel on your desktop computer to
give you easy access to copies of your workbooks. You can create new
workbooks on your 700 Series Computer, or you can copy workbooks
from your desktop computer to your 700 Series Computer. Synchronize
workbooks between your desktop computer and your 700 Series Computer so that you have the most up-to-date content in both locations.
Creating a Workbook
Use Pocket Excel to create workbooks, such as expense reports and mileage
logs. To create a new file, tap Start → Programs → Pocket Excel → New.
A blank workbook appears. Or, if you have selected a template for new
workbooks in the Options dialog box, that template appears with
appropriate text and formatting already provided. You can open only one
workbook at a time; when you open a second workbook, you will be asked
to save the first. You can save a workbook you create or edit in a variety of
formats, including Pocket Excel (.PXL) and Excel (.XLS).
Pocket Excel contains a list of the files stored on your 700 Series Computer. Tap a file in the list to open it. To delete, make copies of, and send files,
tap and hold a file in the list. Then select the appropriate action from the
pop-up menu.
Pocket Excel provides fundamental spreadsheet tools, such as formulas,
functions, sorting, and filtering. To display the toolbar, tap View →
Toolbar.
52
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Note: If your workbook contains sensitive information, you can protect it
with a password. To do so, open the workbook, tap Edit → Password. Every time you open the workbook, you will need to enter the password, so
choose one that is easy for you to remember but hard for others to guess.
Tips for Working in Pocket Excel
Note the following when working in large worksheets in Pocket Excel:
S View in full-screen mode to see as much of your worksheet as possible.
Tap View → Full Screen. To exit full-screen mode, tap Restore.
S Show and hide window elements. Tap View and then tap the elements
you want to show or hide.
S Freeze panes on a worksheet. First select the cell where you want to
freeze panes. Tap View → Freeze Panes. You might want to freeze the
top and leftmost panes in a worksheet to keep row and column labels
visible as you scroll through a sheet.
S Split panes to view different areas of a large worksheet. Tap View →
Split. Then drag the split bar to where you want it. To remove the split,
tap View → Remove Split.
S Show and hide rows and columns. To hide a hidden row or column, select a cell in the row or column you want to hide. Then tap Format ,
Row or Column → Hide. To show a hidden row or column, tap Tools
→ Go To, and then type a reference that is in the hidden row or column. Then tap Format → Row or Column → Unhide.
For more information on using Pocket Excel, tap Start → Help.
MSN Messenger
Note: MSN Messenger is only available on the Premium Edition of Pocket
PC 2002.
MSN Messenger on your 700 Series Computer is an instant messaging
program that lets you:
S See who is online.
S Send and receive instant messages.
S Have instant message conversations with groups of contacts.
To use MSN Messenger, you must have a Microsoft Passport account or a
Microsoft Exchange e-mail account. You must have a Passport to use MSN
Messenger Service. If you have a Hotmail or MSN account, you already
have a Passport. Once you have obtained either a Microsoft Passport or a
Microsoft Exchange account, you are ready to set up your account.
S Sign up for a Microsoft Passport account at http://www.passport.com.
S Get a free Microsoft Hotmail e-mail address at http://www.hotmail.com.
To switch to MSN Messenger, tap Start → Programs → MSN Messenger.
700 Series Color Mobile Computer User’s Manual
53
Chapter 2 — Pocket PC 2002
Setting Up
Before you can connect, you must enter Passport or Exchange account information. To set up an account and sign in:
1 In the Tools menu, tap Options.
2 In the Accounts tab, enter your Passport or Exchange account information.
3 To sign in, tap the sign-in screen and enter your e-mail address and password.
Note: If you already use MSN Messenger on your desktop computer, your
contacts will show up on your 700 Series Computer without being added
again.
Working with Contacts
The MSN Messenger window shows all of your messenger contacts at a
glance, divided into Online and Not Online categories. From this view,
while connected, you can chat, send e-mail, block the contact from chatting with you, or delete contacts from your list using the pop-up menu.
Note: To see others online without being seen, in the Tools menu, tap My
Status → Appear Offline.
If you block a contact, you will appear offline but will remain on the
blocked contact’ s list. To unblock a contact, tap and hold the contact, then
tap Unblock on the pop-up menu.
54
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Chatting with Contacts
Tap a contact name to open a chat window. Enter your message in the text
entry area at the bottom of the screen, or tap My Text to enter a preset
message, and tap Send. To invite another contact to a multi-user chat, in
the Tools menu, tap Invite and tap the contact you want to invite.
Note: To switch back to the main window without closing a chat, tap the
Contacts button. To revert back to your chat window, tap Chats and select
the person whom you were chatting with.
700 Series Color Mobile Computer User’s Manual
55
Chapter 2 — Pocket PC 2002
To know if the contact you are chatting with is responding, look for the
message under the text entry area.
For more information on using MSN Messenger, tap Start → Help.
56
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Windows Media Player for Pocket PC
Use Microsoft Windows Media Player for Pocket PC to play digital audio
and video files that are stored on your 700 Series Computer or on a network. To switch to Windows Media Player for Pocket PC, tap Start →
Programs → Windows Media.
Use Microsoft Windows Media Player on your desktop computer to copy
digital audio and video files to your Pocket PC. You can play Windows
Media and MP3 files on your Pocket PC.
For more information about using Windows Media Player for Pocket PC,
tap Start → Help.
700 Series Color Mobile Computer User’s Manual
57
Chapter 2 — Pocket PC 2002
Microsoft Reader
Use Microsoft Reader to read eBooks on your 700 Series Computer.
Download books to your desktop computer from your favorite eBook Web
site. Then, use ActiveSync to copy the book files to your activated 700 Series Computer. The books appear in the Reader Library, where you can tap
them in the list to open them. Each book consists of a cover page, an optional table of contents, and the pages of the book. You can:
S Page through the book by using the Up/Down control on your 700 Series Computer or by tapping the page number on each page.
S Annotate the book with highlighting, bookmarks, notes, and drawings.
S Search for text and look up definitions for words.
The Guidebook contains all the information you will need to use the software. To open the Guidebook, tap Help on the Reader command bar. Or,
on a book page, tap and hold on the book title, and then tap Help on the
pop-up menu. To switch to Microsoft Reader, tap Start → Programs →
Microsoft Reader.
Getting Books on Your 700 Series Computer
You can download book files from the Web. Just visit your favorite eBook
retailer and follow the instructions to download the book files.
Sample books and a dictionary are also included in the MSReader folder in
the Extras folder on the Pocket PC Companion CD.
Use ActiveSync to download the files from your desktop computer to your
activated mobile computer as described in the Read Me file in the
MSReader folder.
58
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Using the Library
The Library is your Reader home page; it displays a list of all books stored
on your 700 Series Computer or storage card. To open the Library:
1 On the Reader command bar, tap Library.
2 On a book page, tap the book title, then tap Library on the pop-up
menu.
3 To open a book, tap its title in the Library list.
700 Series Color Mobile Computer User’s Manual
59
Chapter 2 — Pocket PC 2002
Reading a Book
Each book consists of a cover page, an optional table of contents, and the
pages of the book. Navigation options are listed in the bottom portion of
the cover page.
The first time you open a book, you will probably want to go to the first
page or to the table of contents, if there is one. Subsequently, whenever
you open the book, you will be automatically taken to the last page read.
In addition to the text, each book page includes a page number and book
title.
You can also page through a book by using the Up/Down control on your
700 Series Computer.
60
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Using Reader Features
Reading a book electronically gives you several options not available with
paper books. These options are available from any book page.
Select text by dragging across the text on the page. Then, tap an option on
the pop-up menu, as described here:
S Searching for Text
Find text in a book by tapping Find on the pop-up menu. Enter the
word you want to search for, and tap the desired Find option. Reader
highlights found text on the page. To close Find, tap outside the box.
To return to your original page, tap the title and then tap Return on the
pop-up menu.
S Copying Text
You can copy text from books that support this feature into any program that accepts text. On a book page, select the text you want to copy.
Then, tap Copy Text on the pop-up menu. The text can be pasted into
the program of your choice.
S Adding Bookmarks
When you add a bookmark to a book, a color-coded bookmark icon
appears in the right margin. You can add multiple bookmarks to a book.
Then, from anywhere in the book, tap the bookmark icon to go to the
bookmarked page.
S Highlighting Text
When you highlight text, it appears with a colored background.
S Attaching Notes to Text
When you attach a note to text, you enter the text in a notepad that appears on top of the book page. A Note icon will display in the left margin. To show or hide the note, tap the icon.
S Adding Drawings
When you add a drawing, a Drawing icon appears in the bottom-left
corner of the page, and drawing tools appear across the bottom of the
page. Draw by dragging your stylus.
S Annotations Index
To see a list of a book’ s annotations, including bookmarks, highlights,
text notes, and drawings, tap Annotations Index on the book’ s cover
page. You can tap an entry in the list to go to the annotated page.
Removing a Book
When you finish reading a book, you can delete it to conserve space on
your 700 Series Computer. If a copy of the book is stored on your desktop
computer, you can download it again at any time.
To remove a book from your 700 Series Computer, tap and hold the title
in the Library list, and then tap Delete on the pop-up menu.
700 Series Color Mobile Computer User’s Manual
61
Chapter 2 — Pocket PC 2002
Pocket Internet Explorer
Note: The Professional Edition of Pocket Internet Explorer does not support WAP pages.
Use Microsoft Pocket Internet Explorer to view Web or WAP pages in either of these ways:
S During synchronization with your desktop computer, download your
favorite links and mobile favorites that are stored in the Mobile Favorites subfolder in Internet Explorer on the desktop computer.
S Connect to an ISP or network and browse the Web. To do this, you will
need to create the connection first, as described in “Getting Connected”
on page 67.
When connected to an ISP or network, you can also download files and
programs from the Internet or intranet.
To switch to Pocket Internet Explorer, tap Start → Internet Explorer.
The Mobile Favorites Folder
Only items stored in the Mobile Favorites subfolder in the Favorites folder
in Internet Explorer on your desktop computer will be synchronized with
your 700 Series Computer. This folder was created automatically when
you installed ActiveSync.
Favorite Links
During synchronization, the list of favorite links in the Mobile Favorites
folder on your desktop computer is synchronized with Pocket Internet Explorer on your 700 Series Computer. Both computers are updated with
changes made to either list each time you synchronize. Unless you mark
the favorite link as a mobile favorite, only the link will be downloaded to
your 700 Series Computer, and you will need to connect to your ISP or
network to view the content. For more information on synchronization,
see ActiveSync Help on the desktop computer.
Mobile Favorites
If you are using Microsoft Internet Explorer 5.0 or later on your desktop
computer, you can download mobile favorites to your 700 Series Computer. Synchronizing mobile favorites downloads Web content to your 700
Series Computer so that you can view pages while you are disconnected
from your ISP and desktop computer.
Use the Internet Explorer plug-in installed with ActiveSync to create mobile favorites quickly. To create a mobile favorite:
1 In Internet Explorer on your desktop computer, click Tools → Create
Mobile Favorite.
2 To change the link name, enter a new name in the Name box.
3 Optionally, in Update, select a desired update schedule.
62
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
4 Click OK. Internet Explorer downloads the latest version of the page to
your desktop computer.
5 If you want to download the pages that are linked to the mobile favorite
you just created, in Internet Explorer on the desktop computer,
right-click the mobile favorite just created and then click Properties. In
the Download tab, specify the number of links deep you want to
download. To conserve 700 Series Computer memory, go only one level
deep.
6 Synchronize your 700 Series Computer and desktop computer. Mobile
favorites that are stored in the Mobile Favorites folder in Internet Explorer are downloaded to your 700 Series Computer.
Note: If you did not specify an update schedule in step 3 above, you will
need to manually download content to keep the information updated on
your desktop computer and 700 Series Computer. Before synchronizing
with your 700 Series Computer, in Internet Explorer on your desktop
computer, click Tools → Synchronize. You will see the last time content
was downloaded to the desktop computer, and you can manually download
content if needed.
You can add a button to the Internet Explorer toolbar for creating mobile
favorites. In Internet Explorer on your desktop computer, click View →
Toolbars → Customize.
Mobile favorites take up storage memory on your 700 Series Computer.
To minimize the amount of memory used:
S In the settings for the Favorites information, type in ActiveSync options,
turn off pictures and sounds, or stop some mobile favorites from being
downloaded to the 700 Series Computer. For more information, see ActiveSync Help.
S Limit the number of downloaded linked pages. In Internet Explorer on
the desktop computer, right-click the mobile favorite you want to
change and then Properties. In the Download tab, specify “0” or “1” for
the number of linked pages you want to download.
700 Series Color Mobile Computer User’s Manual
63
Chapter 2 — Pocket PC 2002
Using AvantGo Channels
AvantGo is a free interactive service that gives you access to personalized
content and thousands of popular Web sites. You subscribe to AvantGo
channels directly from your 700 Series Computer. Then, you synchronize
your 700 Series Computer and desktop computer, or connect to the Internet to download the content. For more information, visit the AvantGo
Web site. To sign up for AvantGo:
1 In ActiveSync options on the desktop computer, turn on synchronization for the AvantGo information type.
2 In Pocket Internet Explorer on your 700 Series Computer, tap the Favorites button to display your list of favorites.
3 Tap the AvantGo Channels link.
4 Tap the Activate button.
5 Follow the directions on the screen. You will need to synchronize your
700 Series Computer with your desktop computer and then tap the My
Channels button to complete the AvantGo setup.
When synchronization is complete, tap the AvantGo Channels link in
your list of favorites to see a few of the most popular channels. To add or
remove channels, tap the Add or Remove link.
64
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Using Pocket Internet Explorer
You can use Pocket Internet Explorer to browse mobile favorites and channels that have been downloaded to your 700 Series Computer without
connecting to the Internet. You can also connect to the Internet through
an ISP or a network connection and browse the Web.
700 Series Color Mobile Computer User’s Manual
65
Chapter 2 — Pocket PC 2002
Viewing Mobile Favorites and Channels
1 Tap the Favorites button to display your list of favorites.
2 Tap the page you want to view.
You will see the page that was downloaded the last time you synchronized
with your desktop computer. If the page is not on your 700 Series Computer, the favorite will be dimmed. You will need to synchronize with your
desktop computer again to download the page to your 700 Series Computer, or connect to the Internet to view the page.
Browsing the Internet
1 Set up a connection to your ISP or corporate network using Connections, as described in “Getting Connected” on page 67.
2 To connect and start browsing, do one of the following:
S Tap the Favorites button, and then tap the favorite you want to view.
S Tap View → Address Bar. In the address bar that appears at the top
of the screen, enter the Web address you want to visit and then tap
Go. Tap the arrow to choose from previously entered addresses.
Note: To add a favorite link while using the 700 Series Computer, go to
the page you want to add, tap and hold on the page, and tap Add to
Favorites.
66
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Getting Connected
You can use your 700 Series Computer to exchange information with other 700 Series Computers as well as your desktop computer, a network, or
the Internet. You have the following connection options:
S Use the infrared (IR) port on your 700 Series Computer to send and
receive files between two 700 Series Computers. If this is the method
you want to use, see “Transferring Items Using Infrared” below.
S Connect to your ISP. Once connected, you can send and receive e-mail
messages by using Inbox and view Web or WAP pages by using Pocket
Internet Explorer. The communication software for creating an ISP connection is already installed on your 700 Series Computer. Your service
provider will provide software needed to install other services, such as
paging and fax services. If this is the method you want to use, see “Connecting to an Internet Service Provider” on page 68.
S Connect to the network at your company or organization where you
work. Once connected, you can send and receive e-mail messages by
using Inbox, view Web or WAP pages by using Pocket Internet Explorer,
and synchronize with your desktop computer. If this is the method you
want to use, see “Connecting to Work” on page 70.
S Connect to your desktop computer to synchronize remotely. Once connected, you can synchronize information such as your Pocket Outlook
information. If this is the method you want to use, see ActiveSync Help
on your desktop computer or Connections Help on the 700 Series
Computer.
Transferring Items Using Infrared
Using infrared (IR), you can send and receive information, such as contacts and appointments, between two 700 Series Computers.
Sending Information
1 Switch to the program where you created the item you want to send and
locate the item in the list.
2 Align the IR ports so that they are unobstructed and within a close
range.
3 Tap and hold the item, and tap Beam Item on the pop-up menu.
Note: You can also send items, but not folders, from File Explorer. Tap
and hold the item you want to send, and then tap Beam File on the popup menu.
Receiving Information
1 Align the IR ports so that they are unobstructed and within a close
range.
2 Have the owner of the other 700 Series Computer send the information
to you. Your 700 Series Computer will automatically receive it.
700 Series Color Mobile Computer User’s Manual
67
Chapter 2 — Pocket PC 2002
Connecting to an Internet Service Provider
You can connect to your ISP, and use the connection to send and receive
e-mail messages and view Web or WAP pages. You can connect to your
ISP in one of two ways:
S Create a modem connection. If this is the method you want to use, see
“Creating a Modem Connection to an ISP” below.
S Use an Ethernet card and a net tap to connect to the network. If this is
the method you want to use, see “Creating an Ethernet Connection to an
ISP” on page 69.
Creating a Modem Connection to an ISP
1 Obtain the following information from your ISP. Some ISPs require information in front of the user name, such as MSN/username.
S ISP dial-up access telephone number
S User name
S Password
S TCP/IP settings
2 If your 700 Series Computer does not have a built-in modem, install a
modem card, or use or use a NULL modem cable and appropriate
adapters to connect an external modem to your 700 Series Computer
through the serial port.
3 Tap Start → Settings → the Connections tab → Connections. Under
The Internet settings, select Internet Settings → Modify.
4 In the Modem tab, tap New.
5 Enter a name for the connection, such as “ISP Connection.”
6 In Select a modem list, select your modem type. If your modem type
does not appear, try reinserting the modem card. If you are using an external modem that is connected to your 700 Series Computer with a
cable, select “Hayes Compatible on COM1.”
7 You should not need to change any settings in Advanced. Most ISPs
now use a dynamically-assigned address. If the ISP you are connecting
to does not use a dynamically-assigned address, tap Advanced → the
TCP/IP tab, then enter the address. When finished, tap OK → Next.
8 Enter the access phone number, and tap Next.
9 Select other desired options, and tap Finish.
10 In the Dialing Locations tab, specify your current location and phone
type (most phone lines are tone). These settings will apply to all connections you create.
68
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
To start the connection, simply start using one of the following programs.
Your 700 Series Computer will automatically begin connecting. Once connected, you can:
S Send and receive e-mail messages by using Inbox. Before you can use
Inbox, you need to provide the information it needs to communicate
with the e-mail server. For specific instructions, see “Connecting Directly
to an E-mail Server” on page 72.
S Visit Web and WAP pages by using Pocket Internet Explorer. For more
information, see “Pocket Internet Explorer” on page 62.
S Send and receive instant messages with MSN Messenger. For more information, see “MSN Messenger” on page 53.
Creating an Ethernet Connection to an ISP
1 You do not need to create a new connection on your 700 Series Computer. Instead, you must purchase a dock to enable on-board Ethernet
or purchase a CompactFlash Ethernet card that is compatible with your
700 Series Computer.
2 Obtain the following information from your ISP:
S User name
S Password
S Domain name
3 Insert the Ethernet card into your 700 Series Computer. For instructions on inserting and using the Ethernet card, see the owner’ s manual.
If using an on-board Ethernet, place your 700 Series Computer in a dock,
tap Start → Today, then look in the System Tray for the Ethernet icon
(shown left). If not there, then tap the antenna icon for the NDISTRAY
pop-up menu and select Built-in Ethernet from the menu.
4 The first time you insert the card, Network Settings will appear
automatically so that you can configure the Ethernet card. Most
networks use DHCP, so you should not have to change these settings
unless your network administrator instructs you to do so. Tap OK. (If it
does not appear or to change settings later, tap Start → Settings → the
Connections tab → Network, tap the adapter you want to change, and
then tap Properties.)
S If using an on-board Ethernet, then select Start → Settings → the
Connections tab → Network Adapters. Select “NE2000 Compatible
Ethernet Driver” from the list of adapters installed, then tap Properties to configure the Ethernet driver.
700 Series Color Mobile Computer User’s Manual
69
Chapter 2 — Pocket PC 2002
5 Connect the Ethernet card or dock to the network by using a network
cable. For information, see your owner’ s manual.
6 Tap Start → Settings → the Connections tab → Connections. From
the My network card connects to list, select “Internet.”
To start the connection, simply start using one of the programs listed in
the preceding section. Once connected, you can perform the same activities as listed in the preceding section.
Connecting to Work
If you have access to a network at work, you can send e-mail messages,
view intranet pages, synchronize your 700 Series Computer, and possibly
access the Internet. You can connect to work in one of two ways:
S Create a modem connection by using a RAS (Remote Access Server) account. Before you can create this modem connection, your network administrator will need to set up a RAS account for you. If this is the
method you want to use, see “Creating a Modem Connection to Work”
below. Your network administrator may also give you VPN settings.
S Use an Ethernet card and a net tap to connect to the network. If this is
the method you want to use, see “Creating an Ethernet Connection to
Work” on page 71.
Creating a Modem Connection to Work
1 Get the following information from your network administrator:
S Dial-up access telephone number
S User name
S Password
S Domain name
S TCP/IP settings
2 If your 700 Series Computer does not have a built-in modem, install a
modem card.
3 Tap Start → Settings → the Connections tab → Connections. Under
The Internet settings, select Internet Settings and tap Modify.
4 In the Modem tab, tap New.
5 Enter a name for the connection, such as “Company Connection.”
6 In the Select a modem list, select your modem type. If your modem
type does not appear, try reinserting the modem card. If you are using
an external modem that is connected to your 700 Series Computer with
a cable, select “Hayes Compatible on COM1.”
7 You should not need to change any settings in Advanced. Most servers
now use a dynamically-assigned address. If the server you are connecting
to does not use a dynamically-assigned address, tap Advanced → the
TCP/IP tab and then enter the address. When finished, tap OK →
Next.
70
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
8 Enter the access phone number, and tap Next.
9 Select other desired options, and tap Finish.
10 In the Dialing Locations tab, specify your current location and phone
type (most phone lines are tone). These settings will apply to all connections you create.
To start the connection, start using one of the following programs. Your
700 Series Computer will automatically begin connecting. Once connected, you can:
S Send and receive e-mail messages by using Inbox. Before you can use
Inbox, you need to provide the information it needs to communicate
with the e-mail server. For specific instructions, see “Connecting Directly
to an E-mail Server” on page 72.
S Visit Internet or intranet Web or WAP pages via Pocket Internet Explorer.
S Send and receive instant messages with MSN Messenger. For more information, see “MSN Messenger” on page 53.
S Synchronize. For more information, see ActiveSync Help on the desktop
computer.
Creating an Ethernet Connection to Work
1 You do not need to create a new connection on your 700 Series Computer. Instead, you must purchase a dock to enable on-board Ethernet
or purchase a CompactFlash Ethernet card that is compatible with your
700 Series Computer.
2 Obtain the following information from your ISP:
S User name
S Password
S Domain name
3 Insert the Ethernet card into your 700 Series Computer. For instructions on inserting and using the Ethernet card, see the owner’ s manual.
S If using an on-board Ethernet, place your 700 Series Computer in a
dock, tap Start → Today, then look in the System Tray for the Ethernet icon (shown left). If not there, then tap the antenna icon for the
NDISTRAY pop-up menu and select Built-in Ethernet from the
menu.
700 Series Color Mobile Computer User’s Manual
71
Chapter 2 — Pocket PC 2002
4 The first time you insert the card, Network Settings will appear
automatically so that you can configure the Ethernet card. Most
networks use DHCP, so you should not have to change these settings
unless your network administrator instructs you to do so. Tap OK. (If it
does not appear or to change settings later, tap Start → Settings → the
Connections tab → Network, tap the adapter you want to change, and
then tap Properties.)
S If using an on-board Ethernet, then select Start → Settings → the
Connections tab → Network Adapters. Select “NE2000 Compatible
Ethernet Driver” from the list of adapters installed, then tap Properties to configure the Ethernet driver.
5 Connect the Ethernet card or dock to the network by using a network
cable. For information, see your owner’ s manual.
6 To synchronize your 700 Series Computer, tap Start → ActiveSync. In
the Tools menu, tap Options. → the PC tab, select Include PC when
synchronizing remotely and connect to, and select your computer’ s
name. Remote synchronization with a desktop computer will work only
if a partnership is set up with that computer through ActiveSync and
ActiveSync is set to allow remote connections. Other restrictions apply.
For more information, see ActiveSync Help on the desktop computer.
To start the connection, simply start using one of the programs listed in
the preceding section. Once connected, you can perform the same activities as listed in the preceding section.
Ending a Connection
To disconnect, do one of the following:
S When connected via dial-up or VPN, tap the Connection icon (shown
left) on your navigation bar, and then tap End.
S When connected via cable or cradle, detach your 700 Series Computer
from the cable or cradle.
S When connected via Infrared, move the 700 Series Computer away
from the PC.
S When connected via a network (Ethernet) card, remove the card from
your 700 Series Computer.
Connecting Directly to an E-mail Server
You can set up a connection to an e-mail server so that you can send and
receive e-mail messages by using a modem or network connection and Inbox on your 700 Series Computer.
Note: The ISP or network must use a POP3 or IMAP4 e-mail server and
an SMTP gateway.
You can use multiple e-mail services to receive your messages. For each email service you intend to use, first set up and name the e-mail service. If
you use the same service to connect to different mailboxes, set up and
name each mailbox connection.
72
700 Series Color Mobile Computer User’s Manual
Chapter 2 — Pocket PC 2002
Setting Up an E-mail Service
S In Inbox on your 700 Series Computer, tap Services → New Service.
Follow the directions in the New Service wizard.
For an explanation of a screen, tap Start → Help. When finished, to connect to your e-mail server, tap Services → Connect. For more information
on using the Inbox program, see “Inbox: Sending and Receiving E-mail Messages” on page 42.
700 Series Color Mobile Computer User’s Manual
73
Chapter 2 — Pocket PC 2002
74
700 Series Color Mobile Computer User’s Manual
3
Installing Applications
There are multiple ways to get an application to your 700 Series Color
Mobile Computer; just as there are multiple ways to package the application for delivery.
700 Series Color Mobile Computer User’s Manual
75
Chapter 3 — Installing Applications
Packaging an Application
Use any of the following methods to package an application for installation:
S For very simple applications, the application itself might be the only file
that needs to be delivered.
S It could be a directory structure that contains the application, supporting files like ActiveX controls, DLLs, images, sound files, and data files.
S Via a CAB file.
Consider either of the following when choosing a location into which to
store your application:
S In the basic 700 Series Computer, there are no built-in storage options
other than the Object Store. The Object Store is RAM that looks like a
disk. Anything copied here will be deleted when a cold-boot is performed on the 700 Series Computer.
S If the optional SecureDigital or CompactFlash storage card is in the system, then consider this card the primary location for placing an applications install files. The following folders represent either card:
S The SecureDigital storage card creates the “\SDMMC Disk” folder.
S The CompactFlash storage card creates the “\Storage Card” folder.
S Files copied to either of these locations will be safe when a cold-boot is
performed on a 700 Series Computer - providing the AutoRun system is
installed onto the storage card. You can find this system on the Recovery
CD. Copying a CAB file to the “\CABFILES” folder on one of these
cards will automatically extract that CAB file on every cold boot to ensure that your system is properly set up. See page 82 for more details on
how this works.
Installing Applications
Consider any of the following options to get the package to the preferred
location on your 700 Series Computer.
S Microsoft ActiveSync
S FTP Server (page 78)
S Application Manager in Unit Manager (page 78)
S SecureDigital or CompactFlash storage card (page 78)
76
700 Series Color Mobile Computer User’s Manual
Chapter 3 — Installing Applications
Using Microsoft ActiveSync
Note: These instructions assume that the 700 Color Management Tools
portion of the 700 Series Color Software Tools CD was installed onto your
desktop.
The Microsoft ActiveSync tool is located on the 700C Companion CD,
which contains Microsoft products, such as Outlook and ActiveSync. See
Chapter 2, “Pocket PC 2002,” for information about this tool as provided
by Microsoft Corporation.
This can be a serial, USB, Ethernet, InfraRed, or 802.11b ActiveSync connection. Files can then be copied using File Explorer on a PC or a laptop
computer. This option is usually only good when updating a few 700 Series Computers.
These instructions assume that Microsoft ActiveSync had been installed
onto your desktop computer and is up and running. If not, go to Chapter
2, “Pocket PC 2002,” for an URL from which you can download the latest
application.
1 Connect your 700 Series Computer to your desktop computer via an
ActiveSync cable or IrDA.
2 Wait for a “Connected” message to appear in the Microsoft ActiveSync
application to signal a connection to the 700 Series Computer. If necessary, select File → Get Connected to initiate a connection.
3 Click Explore to access the Mobile Device directory on your 700 Series
Computer.
700 Series Color Mobile Computer User’s Manual
77
Chapter 3 — Installing Applications
4 From your desktop, select Start → Windows Explorer, then browse the
applicable path for any of the system files needed for your 700 Series
Computer (listed with their paths). Select to highlight the appropriate
file, right-click the file for a pop-up menu, then select Copy.
S Base operating system files:
“C:\Intermec\Intermec 700 Color Mgmt Tools\Drive Images”
S CAB files:
“C:\Intermec\Intermec 700 Color Mgmt Tools\Cab Files”
5 Within the Mobile Device directory, go to the directory where you want
the files located on the 700 Series Computer, do a right-click for a popup menu, then select Paste.
6 When all of the files are pasted, perform a warm-boot on the 700 Series
Computer. When the computer reboots, wait for the LED on the top
left of your keypad to stop blinking. Tap Start → Programs → File Explorer to locate the newly copied executable files, then tap these files to
activate their utilities.
Using the FTP Server
The 700 Series Computer has a built-in FTP Server that connects to a network via Ethernet or 802.11b. This “ftp”s to the IP address of the 700 Series Computer and places files. The benefit of using FTP is that a script
can be created that will automate the process of copying files to the 700
Series Computer. This option is good for when a large number of 700 Series Computers need to be updated. See Chapter 7, “Programming,” for
more information.
Using the Application Manager in Unit Manager
This requires the 700 Series Computer to connect to the network via
Ethernet or 802.11b. The process is still manual so it would take longer
than the FTP method but it would still be a better option than ActiveSync
where many 700 Series Computers need to be updated. The Unit Manager
applications are available on the 700 Series Color Unit Manager CD-ROM.
For more information, consult your Intermec sales representative.
Using a Storage Card
The following steps pertain to installing an application using a storage
card.
Copying to a CompactFlash Card
Follow the steps below to install your application on the device using a
CompactFlash storage card:
1 Suspend the 700 Series Color Mobile Computer and remove its CompactFlash drive, which holds a SanDisk CompactFlash storage card.
2 Using a CompactFlash Adapter card, place the CompactFlash Drive in
your desktop PC card drive.
78
700 Series Color Mobile Computer User’s Manual
Chapter 3 — Installing Applications
3 Create a subdirectory on the PCMCIA CompactFlash drive in which to
store your application.
4 Add the autorun system to the storage card using the CEImager
application. See the Software Tools User’ s Manual for information about
CEImager.
5 Copy your application, data files, and all required DLLs and drivers to
the subdirectory created on the CompactFlash drive.
6 Add your application to the AUTOUSER.DAT file on the
“\Storage Card\2577” directory that contains the following statement,
where your directory is the directory on the CompactFlash storage card
where the application was installed, and yourapp.exe is the name of your
application. Finish the “RUN=” statement with a carriage return linefeed combination. There may be multiple run statements in the file.
RUN=\\
7 Remove the CompactFlash drive from your desktop computer and reinstall it into the 700 Series Computer.
8 Warm-boot the 700 Series Computer to add these files to the CompactFlash storage card.
If the AUTOUSER.DAT file is found and the “RUN=” statement is correct, then the task manager will launch and execute your program on startup.
Copying to a SecureDigital Storage Card
Do the same steps as for the CompactFlash storage Card, except replace
the “\Storage Card\2577” directory with the “\SDMMC Disk\2577” directory.
Updating the System Software
You can use the Recovery CD to reinstall or update the operating system
software on the 700 Series Color Computer. For more information, contact your Intermec sales representative.
700 Series Color Mobile Computer User’s Manual
79
Chapter 3 — Installing Applications
Application Migration
Note: These instructions assume that the 700 Color Management Tools
portion of the 700C Software Tools CD was installed onto your desktop
and that a storage card has been added to the base configuration of the 700
Color Computer.
The following steps are required to ensure that the following will happen
on a cold-boot:
S CAB files can be restored,
S applications will automatically start,
S and the registry will be restored.
Do the following for the cold-boot procedure:
1 From your desktop, double-click the Intermec CE Imager desktop icon
to access the Intermec CEImager application. If this icon is not on your
desktop, then double-click the CEIMAGER.EXE executable from the
“C:\Intermec\Intermec 700 Color Mgmt Tools\Tools\CEImager” folder.
2 Click Default under Components List to activate the components.
3 Click (+) to expand the AutoRun System component, click (+) to expand the Destination Media option, then select either the CompactFlash Card option or the SecureDigital Card option. Do not select both
storage cards, as the AutoRun files copied will work for one storage card, but
not work on the other storage card.
80
700 Series Color Mobile Computer User’s Manual
Chapter 3 — Installing Applications
4 Click Install to install the AUTORUN files onto the storage card.
5 Create a “\Cabfiles” folder on the storage card. Copy any CAB files that
are to be extracted on every startup into this folder.
6 In the “\2577” directory, add your custom AUTOUSER.DAT file. See
the Recovery Help for more information on how to set up an
AUTOUSER.DAT file.
7 If you are using the RegFlushKey() API, the application must use a special API to make sure the registry is written to the appropriate card; or
you can use the Utilities control panel applet, as follows:
a From the 700 Series Computer, tap Start → Settings → the System
tab → the Utilities icon → the Registry Save tab.
b Tap Enable Registry Storage, then tap either of the following:
S SD
To write the registry to the SecureDigital storage card.
S CF
To write the registry to the CompactFlash storage card.
c Tap ok to save your entry and exit the Utilities control panel applet.
Note: If you are using a SecureDigital storage card, you must change any
disk access from “Storage Card” to “SDMMC Disk.”
8 Remove the storage card from the desktop PC and install the card into
the 700 Series Color Computer.
9 Perform a cold-boot on the 700 Series Color Computer. Files will
automatically install from the storage card upon reboot. Any calls to the
RegFlushKey() API will automatically write the registry to the
appropriate location.
700 Series Color Mobile Computer User’s Manual
81
Chapter 3 — Installing Applications
When converting a 700 Series Monochrome Computer application to run
on the 700 Series Color Computer, most APIs should work without changes. Below are a few exceptions:
S The 700 Series Monochrome Computer used the “\Storage Card” folder
for nonvolatile storage. You may need to change the application to store
data in a volatile location or onto the “SDMMC Disk” if a SecureDigital storage card is present in the system.
S If the application uses the RegFlushKey() API, it must first verify that
the proper media is available in the system and call the special API mentioned in Step 7 on the previous page.
S If the application will be using the 700 Color switchable dock, use the
API to set the proper port on the dock before communications.
S Some WAN radio options have changed. Review the WAN radio section
to determine if any changes will be required in your application.
S The arrow and tab keys are swapped from the way they were on the 700
Series Monochrome Computers. Keyboard remapping is available on
the 700 Series Color Computer if these keys need to be changed. See
page 79 for more details.
S No special SDK is needed to compile applications for the Xscale processor. Targeting the SA1110 processor will create applications that run on
the 700 Series Color Computer.
Cabinet File Installation
CAB files (short for cabinet files) are like .ZIP files, plus they register DLLs,
create shortcuts, modify registry entries, and run custom set up programs.
Tap a CAB file to extract that file or place the CAB file on one of the approved storage devices in the “\Cab Files” folder, then perform a warmboot on the 700 Series Computer. There are two methods available to extract a CAB file:
S Tap a CAB file to extract it. When using this method, the CAB file is
automatically deleted when the extraction process is successful, unless
the CAB file is set with the read-only attribute.
S Use the AUTOCAB method where all files are extracted when a coldboot is performed on the 700 Series Computer. This AutoCab application is on the Recovery CD, see its “Recovery Help” for more information.
82
700 Series Color Mobile Computer User’s Manual
4
Network Support
The 700 Series Color Mobile Computer can integrate up to three radios in
a single unit, and will automatically install the appropriate software for radio use when the unit is powered on. The Intermec CORE application
defaults to the most recently used module. If a module has not yet been
used or set, CORE will default to the first module as listed alphabetically.
The following communication options on the 700 Series Computer provide wired and wireless connectivity:
S Onboard wired Ethernet (standard)
S Wireless Local Area Network (LAN)
This 802.11b radio option provides up to 11 Mb/sec throughput.
S Wireless Wide Area Network (WAN)
Includes support for GSM/GPRS and CDMA/1xRTT radios.
S Wireless Printing
This allows for cable-free communications with peripheral devices, such
as printers, over a ten-meter range. This compatibility is provided via a
Bluetooth qualified module by Socket Communications.
700 Series Color Mobile Computer User’s Manual
83
Chapter 4 — Network Support
CORE
The Intermec Common Object Resource Environment (CORE) application provides a framework for various modules that let you configure and
manage your Intermec products. These modules are software plug-ins that
can be configuration tools, such as the 802.11b radio configuration module, or they can provide information on your environment, such as a battery life module.
CORE is built into the operating system of every 700 Series Computer.
On the 700 Series Computer, tap Start → Programs → the Intermec
CORE icon to access this application.
CORE modules are collections of specific information. This information is
usually related to a particular radio technology, but not always. Each
module can display general and detailed information. Tap the General and
Details tabs near the bottom to switch between general and detailed
information. Note that not all modules will have detailed information.
To learn more about this application, see its online help. Tap Start →
Help from the menu to see the CORE online help.
Note: Once CORE is running, you can return to it by tapping its icon
from the System Tray via the Today screen. Tap Start → Today → the
Intermec CORE three-ring icon (circled in the following illustration).
84
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
Network Adapters
Your 700 Series Computer can have up to three radios installed. The default network adapter or radio is dependent on what card is inserted in
your 700 Computer. Below are the the network adapters that exist as of
this publication. See the Developer’s Support web site for the latest information on network adapters for your unit.
S Ethernet Communications (LAN9000) - page 86.
S 802.11b Radios (802.11b Wireless LAN driver) - page 87.
S WWAN (Wireless WAN) - page 110.
S Wireless Printing (PAN) - page 120.
Note that the tip of the antenna attached to your 700 Series Computer is
color-coded to identify its radio type. Refer to the following to determine
your radio type:
S Green
802.11b diversity
S Red
CDMA (non-Sprint networks)
S White
GPRS US/Canada and CDMA Sprint networks
S Blue
GPRS International
700 Series Color Mobile Computer User’s Manual
85
Chapter 4 — Network Support
Ethernet Communications
Follow the steps below to start Ethernet communications on the 700 Series
Computer. If your system does not contain an 802.11b radio, then
Ethernet networking using DHCP will be selected as the default.
When “Built-in Ethernet” is selected from the NDISTRY pop-up menu,
then the antenna shown to the left will appear in the System Tray. When
“No networking” is selected, then this icon will appear with a red “X”
above it.
From the 700 Series Computer, tap Start → Settings → the Connections
tab → Network Adapters to access the network connections for this unit.
Make the changes necessary for your network, then tap ok when finished.
Note: “LAN9000” is for Ethernet and ”802.11b Wireless LAN” is for
802.11b radios.
86
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
802.11b Communications
The 700 Series Computer can integrate the 802.11b radio module along
with either the GSM/GPRS or the CDMA/1xRTT radio and the Wireless
Printing option. The 802.11b radio module accommodates any Wireless
LAN (WLAN) requirements, such as using WLAN access points for crossdocking or load-planning applications.
When “Wireless 802.11” is selected via the NDISTRY pop-up menu, then
the antenna shown to the left will appear in the System Tray.
To start 802.11b communications on the 700 Series Computer, tap Start
→ Settings → the System tab → the Wireless Network icon to access the
Profile Wizard for the 802.11b radio module. The Profile Wizard defaults
to the Profiles page.
Profiles
Use the Profiles page to add, edit, or delete multiple networking environments for this 802.11b radio. To add a profile from this screen, enter up to
32 alphanumeric characters in the Profile field, then tap Add. See “Basic”
on page 89 and “Security” on page 90 for more information.
Leave Use Profile Name for SSID checked for the SSID (or Network
Name) to use this profile name. If this is cleared (check mark removed),
the SSID will default to using the factory-assigned “INTERMEC” network name.
700 Series Color Mobile Computer User’s Manual
87
Chapter 4 — Network Support
S To add a profile:
Tap Add, enter up to 32 alphanumeric characters to name this profile if
you have not already entered a description in the Profiles page, configure the basic and security information for this profile, then click Done to
configure its basic and security information.
S Leave Use Profile Name for SSID checked for the SSID to use this assigned profile name. If this is cleared (check mark removed), the SSID
will default to using the factory-assigned “INTERMEC” network name.
Go to the next page to continue.
S To edit a profile:
Select an existing profile from the Profile drop-down list, tap Edit,
make the changes needed for this profile (starting in the next paragraph), then tap OK to return to the Profiles page.
S To delete a profile:
Select a profile from the Profile drop-down list, tap Delete, then tap Yes
to remove the selected profile.
88
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
Basic
Use the Basic page to set the network type and radio channel for this profile. Click OK to return to the Profiles page.
S Network type:
Tap the drop-down list to select either Infrastructure or Ad-hoc.
S SSID (Network Name):
This assumes the profile name when Use Profile Name for SSID is
checked on the previous screen, unless another name is entered in this
field. If you want to connect to the next available network or are not
familiar with the network name, enter “ANY” in this field. Consult your
LAN administrator for network names.
S Channel:
If “Ad-hoc” were selected as the network type, then this is enabled. Tap
the drop-down list to select a channel, from 1-15, through which to
handle connections (default is 3).
S Enable Power Management:
Check this box to conserve battery power (default), or clear this box to
disable this feature.
700 Series Color Mobile Computer User’s Manual
89
Chapter 4 — Network Support
Security
Use the Security page to set this profile as read-only or to enable WEP
(Wired Equivalent Privacy) encryption. Click OK to return to the Profiles
page. The following securities are available from the Security Method
drop-down list. Note that the last three methods are available if you have purchased the security package. Contact your Intermec Representative for more information.
S 802.11 WEP Encryption (next page)
S 802.1x TLS (page 92)
S 802.1x TTLS (page 93)
S LEAP (page 93)
90
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
802.11 WEP Encryption:
WEP keys are only needed if they are expected by your clients. There are
two types available: 64-bit (5-character strings, 12345) (default) and
128-bit (13-character strings, 1234567890123). These can be entered as
either ASCII (12345) or Hex (0x3132333435).
To enter WEP keys, select “802.11 WEP Encryption” from the Security
Method drop-down list. Select a data transmission key from the Data TX
Key drop-down list near the bottom of this screen, then enter the encryption key for that data transmission in the appropriate Key # field.
700 Series Color Mobile Computer User’s Manual
91
Chapter 4 — Network Support
802.1x TLS (Transport Layer Security):
TLS is a protocol that ensures privacy between communicating applications and their users on the Internet. To use this protocol, select “802.1x
TLS” from the Security Method drop-down list, then enter the following:
S Client Key File:
Enter the file location where the certificate for your identity is stored.
S Password:
Enter the password for the certificate in this field.
S Supplicant ID:
Enter the user ID associated with this certificate.
S Server Cert CN (Certificate Common Name):
Enter the common name of your authentication server.
S CA List (Certificate Authority):
Enter the file location, or path, of the server certificates.
92
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
802.1x TTLS (EAP-Tunneled TLS):
To use this protocol, select “802.1x TTLS” from the Security Method
drop-down list, then enter the following:
S Username:
Enter your user name for this security protocol.
S Password:
Enter your password for this security protocol.
S Supplicant ID:
Enter “anonymous” unless your administrator indicates otherwise.
S Server Cert CN (Certificate Common Name):
Enter the common name of your authentication server.
S CA List:
Enter the file location, or path, of the server certificates.
LEAP (Cisco Wireless EAP (Extensible Authentication Protocol)):
Enter your unique user name and password to use this protocol.
700 Series Color Mobile Computer User’s Manual
93
Chapter 4 — Network Support
Advanced
Use this page to secure the configuration for this profile or to make all
fields read-only.
S Make Profile Read-Only:
Check this box, then enter and reenter a password to “lock” or render
“read-only” all configurations for this profile. To reverse this step, clear
the check box, then enter the password assigned with the “read-only”
status.
S Certificates:
If “802.1x TLS,” “802.1x TTLS,” or “LEAP” were enabled via the Security tab, then this button will appear. Tap this button to configure the
available certificates. See “Certificates” on the next page for more information.
94
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
Certificates
Use this page to view, modify, or remove certificates assigned to your
particular security method. Note that you can also access this page by tapping
Start → certificates from the Today screen.
S CA Name/IP:
Enter a valid CA name or IP address assigned to the certificate in question. This allows you to enroll the certificate or to browse for its latest
information.
S Enroll File Name:
Enter the file name of the certificate to be enrolled.
S Store Location:
Enter the path where the certificate is to be stored within your 700 Series Computer.
S Enroll:
Tap this to assign the file entered in Enroll File Name to the location
specified in Store Location.
S CA Vert:
Tap this to view the contents of the certificate via the Internet Explorer.
S View:
Tap this to view information about the certificate, such as to whom this
certificate was issued, who issued the certificate, and the span of time
the certificate is valid.
S Remove:
Select a file from the list, then tap this button to delete that file.
700 Series Color Mobile Computer User’s Manual
95
Chapter 4 — Network Support
Import/Export
Use this page to send a profile or to retrieve a profile to or from another
location within your 700 Series Computer.
S To export a profile:
Select to highlight a profile, then tap Export. Select from the drop-down
lists, the folder, type of files, and location within the folder where the
profile is to go, tap OK to export the profile, tap ok to close the confirmation screen, then tap OK again to exit the Profile Wizard.
96
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
S To import a profile:
Tap Import to access the Open screen, from the drop-down lists, select a
folder and file type, then tap a profile from the list provided. Tap ok to
close the confirmation screen, then tap OK again to exit the Profile
Wizard.
Scan List
Use this Scan List page to monitor network connections, and if lost, to attempt to reestablish connections with these networks.
Selected Profile
Select this option to use the profile defined in the Profiles page, then tap
OK to exit the Profile Wizard. When connections are lost, attempts will be
made to connect to the specified profile.
700 Series Color Mobile Computer User’s Manual
97
Chapter 4 — Network Support
Scan List
Use this option to select a number of profiles with which to establish connections. When connections are lost, attempts will be made to contact each
of the profiles listed, in the order they appear in the list.
1 Tap this option, then tap Edit Scan List.
2 Select profiles from the Available Profiles drop-down list, then tap Add
to include each selection in the Scan List.
3 To arrange the hierarchy of profiles, tap to select a profile, then tap either Move Up or Move Down to move each profile. To remove a profile from the list, tap to select that profile, then tap Delete.
4 Click either ok or Close to return to the Scan List page, then click OK
to exit the Profile Wizard.
Network Selection APIs
The Network Selection APIs allow the user to change network adapter
configuration programmatically. Both drivers support the same IOCTL
function numbers for loading and unloading the drivers.
Loading and unloading of the 802.11b driver is performed by the FWV1:
device in the system by performing DeviceIOControl() calls to the driver.
Loading and unloading of the driver for the built-in Ethernet adapter is
performed by the SYI1: device in the system by performing DeviceIOControl() calls to the driver.
S For loading an NDIS driver associated with an adapter, the IOCTL is
IOCTL_LOAD_NDIS_MINIPORT.
S For unloading NDIS drivers associated with an adapter the IOCTL is
IOCTL_UNLOAD_NDIS_MINIPORT.
98
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
#include 
#include “sysio.h”
void DoLoad(int nDevice) {
LPTSTR devs[] = { _T(“SYI1:”), _T(“FWV1:”) };
HANDLE hLoaderDev;
DWORD bytesReturned;
hLoaderDev = CreateFile(devs[nDevice], GENERIC_READ|GENERIC_WRITE, 0,
NULL, OPEN_EXISTING, 0, NULL);
if (hLoaderDev != INVALID_HANDLE_VALUE) {
if (!DeviceIoControl( hLoaderDev, IOCTL_LOAD_NDIS_MINIPORT, NULL, -1, NULL, 0,
&bytesReturned, NULL)){
MessageBox(NULL, TEXT(“SYSIO IoControl Failed”), TEXT(“Network
loader”),MB_ICONHAND);
if (hLoaderDev!=INVALID_HANDLE_VALUE) CloseHandle(hLoaderDev);
hLoaderDev = INVALID_HANDLE_VALUE; // bad handle
}else {
CloseHandle(hLoaderDev);
void DoUnload(int nDevice) {
LPTSTR devs[] = { _T(“SYI1:”), _T(“FWV1:”) };
HANDLE hLoaderDev;
DWORD bytesReturned;
hLoaderDev = CreateFile(devs[nDevice], GENERIC_READ|GENERIC_WRITE, 0,
NULL, OPEN_EXISTING, 0, NULL);
if (hLoaderDev != INVALID_HANDLE_VALUE) {
if (!DeviceIoControl( hLoaderDev, IOCTL_UNLOAD_NDIS_MINIPORT, NULL, -1, NULL, 0,
&bytesReturned, NULL)){
MessageBox(NULL, TEXT(“SYSIO IoControl Failed”),TEXT(“Network
loader”),MB_ICONHAND);
if (hLoaderDev!=INVALID_HANDLE_VALUE) CloseHandle(hLoaderDev);
hLoaderDev = INVALID_HANDLE_VALUE; // bad handle
}else {
CloseHandle(hLoaderDev);
700 Series Color Mobile Computer User’s Manual
99
Chapter 4 — Network Support
The API provided by Intermec Technologies exposes a limited set of routines that allows a programmer to access and affect the 802.11b network
interface card from within their application. The routines provided will
also read/write values to the CE registry that pertain to the 802.11b radio
driver. By using the provided functions, a programmer can alter the
802.11b parameters of Network Name (SSID), WEP Keys, Infrastructure
Modes, Radio Channel, and Power Management Modes. A programmer
can also retrieve network connect status and signal strength indication
from the RF network card.
The API is contained within the 80211API.DLL file that should be present in any load that has the 802.11b networking installed.
S NETWLAN.DLL
This file is the 802.11b driver. It will be present in all 700 CE loads that
use the 802.11b network interface card.
S 80211API.DLL
This file is an Intermec authored file that provides the programmer with
a set of API calls to configure or monitor status of the 802.11b network.
S MOD80211.DLL
The CORE module for the 802.11b NIC. It provides the 802.11b status information displayed when the CORE application is running.
S 80211CONF.EXE
This is the “Control Panel” for configuring the 802.11b network parameters. Note that it is an EXE file and is actually called by
CPL802.CPL (see below). It is also called by the CORE application
when the “Configuration” button is pressed.
S CPL802.CPL
A control panel application that does nothing but call
80211CONF.EXE.
S 80211SCAN.EXE
Internally manages the Scan List activity.
The 80211API.DLL supports an unlimited number of radio configuration
profiles. These profiles are the same as those set by the Wireless Network
control panel applet that runs on the Windows CE unit. You can configure
different 802.11b profiles and switch between them using the 802.11 API.
See the ConfigureProfile() function on page 106 for more information.
100
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
Function Summary
Below are functions available for the 700 Series Color Computer when
enabled with the 802.11b radio module.
RadioConnect()
Connects to the available radio. Use this function if you plan on using a
lot of API calls that talk directly to the radio.
Syntax: UINT RadioConnect( );
Parameters: None.
Returns: ERROR_SUCCESS when successful, otherwise
ERR_CONNECT_FAILED.
RadioDisconnect()
Cleans up the connection from the RadioConnect() function after an application closes.
Syntax: UINT RadioDisconnect( );
Parameters: None.
Returns: ERROR_SUCCESS when successful, otherwise
ERR_CONNECT_FAILED.
GetMac()
Gets the radio MAC address.
Syntax: UINT GetMac( TCHAR * );
Parameters: Pointer to a character array, which is populated with MAC addresses.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
GetBSSID()
Gets the associated access point name, the BSSID.
Syntax: UINT GetBSSID( TCHAR * );
Parameters: Pointer to a character array, which is populated with the current BSSID.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed
GetSSID()
Gets the current SSID (network name).
Syntax: UINT GetSSID( TCHAR * );
Parameters: Pointer to a character array, which is populated with the current SSID.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
700 Series Color Mobile Computer User’s Manual
101
Chapter 4 — Network Support
GetLinkSpeed()
Retrieves the current link speed of the radio connection.
Syntax: UINT GetLinkSpeed( int & );
Parameters: &
References an integer.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
GetNetworkType()
Retrieves the network type.
Syntax: UINT GetNetworkType( ULONG & );
Parameters: & References a ULONG value, populated with one of the following:
NDIS_NET_TYPE_FH Frequency Hopping Radio
NDIS_NET_TYPE_DS Direct Sequence Radio
NDIS_NET_TYPE_UNDEFINED
Unknown or information not available.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
GetTXPower()
Gets the current TX power of the radio in milliwatts.
Syntax: UINT GetTXPower( ULONG & );
Parameters: & References a ULONG value, populated with one of the following
in milliwatts (mW):
NDIS_POWER_LEVEL_63
63 mW.
NDIS_POWER_LEVEL_30
30 mW.
NDIS_POWER_LEVEL_15
15 mW.
NDIS_POWER_LEVEL_5
5 mW.
NDIS_POWER_LEVEL_1
1 mW.
NDIS_POWER_LEVEL_UNKNOWN
Unknown Value or Error.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
102
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
GetNetworkMode()
Retrieves the network mode.
Syntax: UINT GetNetworkMode( ULONG & );
Parameters: & References a ULONG value, populated with one of the following:
NDIS_NET_MODE_IBSS
802.11 Ad-Hoc Mode.
NDIS_NET_MODE_ESS
802.11 Infrastructure Mode.
NDIS_NET_MODE_UNKNOWN
Unknown Value or Error.
NDIS_NET_AUTO_UNKNOWN
Automatic Selection. Use of this option is not recommended.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
SetNetworkMode()
Sets the radio and updates the CE registry.
Syntax: UINT SetNetworkMode( ULONG & );
Parameters: & References a ULONG value, populated with one of the values defined
in GetNetworkMode().
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
AddWep()
Adds a WEP key to the radio configuration.
Syntax: UINT AddWep( ULONG 1, BOOL 2, TCHAR * 3 );
Parameters: ULONG
BOOL
TCHAR
Pointer that identifies what key to be set.
Specifies whether the key being set is the default TX key.
Pointer that specifies the key data either in hex (string
lengths of 10 or 26) or ASCII (string lengths of 5 or 13).
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
GetRSSI()
Sets the current RSSI (Received Signal Strength Indication).
Syntax: UINT GetRSSI( ULONG & );
Parameters: &
References a ULONG value.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
700 Series Color Mobile Computer User’s Manual
103
Chapter 4 — Network Support
GetAssociationStatus()
Gets the current connection, or association status.
Syntax: UINT GetAssociationStatus( ULONG & );
Parameters: & References a ULONG value, a current connection status as follows:
NDIS_RADIO_ASSOCIATED Radio is associated w/access point.
NDIS_RADIO_SCANNING
Radio is scanning for network.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
GetWepStatus()
Gets the current WEP status.
Syntax: UINT GetWepStatus( ULONG & );
Parameters: & References a ULONG status value which include the following:
NDIS_RADIO_WEP_ENABLED
WEP is currently enabled.
NDIS_RADIO_WEP_DISABLED
WEP is currently disabled.
NDIS_RADIO_WEP_ABSENT
WEP key is absent.
NDIS_RADIO_WEP_NOT_SUPPORTED
WEP is not supported.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
GetAuthenticationMode()
Gets the current authentication mode.
Syntax: UINT GetAuthenticationMode( ULONG & );
Parameters: & References a ULONG value which include the following current
authentication mode:
NDIS_RADIO_AUTH_MODE_OPEN
Open System is in use.
NDIS_RADIO_AUTH_MODE_SHARED Shared Key is in use.
NDIS_RADIO_AUTH_MODE_AUTO
Automatic Detection.
NDIS_RADIO_AUTH_MODE_ERROR Unknown value/Error.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
SetAuthenticationMode()
Sets the radio authentication mode with a value defined in the
GetAuthenticationMode() function.
Syntax: UINT SetAuthenticationMode( ULONG );
Parameters: Passes in a ULONG set to one of the values as defined in
GetAuthenticationMode().
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
104
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
SetChannel()
Sets the radio channel, ranging from 1 to 14.
Syntax: UINT SetChannel( USHORT );
Parameters: USHORT set to a desired channel (1-14).
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
EnableWep()
Enables or disables WEP encryption.
Syntax: UINT EnableWep( BOOL );
Parameters: Set to TRUE (0) to enable WEP encryption or FALSE (1) to disabled
WEP encryption.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
GetPowerMode()
Gets the current power management mode of the radio.
Syntax: UINT GetPowerMode( ULONG & );
Parameters: & References a ULONG value which include the following current radio
power management mode:
NDIS_RADIO_POWER_MODE_CAM
Continuous Access Mode (uses most power).
NDIS_RADIO_POWER_MODE_MAX
Maximum Power Savings.
NDIS_RADIO_POWER_MODE_PSP
Power Saving Mode, best balance of power and performance.
NDIS_RADIO_POWER_UNKNOWN
Unknown mode reported or error.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
SetSSID()
Passes the desired SSID (network name).
Syntax: UINT SetSSID( TCHAR * );
Parameters: Pointer to a character array that contains the desired SSID.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
700 Series Color Mobile Computer User’s Manual
105
Chapter 4 — Network Support
isOrinoco()
Confirms whether the present radio is an ORiNOCO radio.
Syntax: UINT isOrinoco( );
Parameters: None.
Returns: TRUE when an ORiNOCO radio.
FALSE when other than an ORiNOCO radio.
EncryptWepKeyForRegistry()
Encrypts a key for registry storage. Requires TCHAR pointers for a destination and a source.
Syntax: UINT EncryptWepKeyForRegistry( TCHAR * szDest, TCHAR *
szSource );
Parameters: szDest
szSource
String for the destination.
String for the source.
Returns: ERROR_SUCCESS when successful,
ERR_QUERY_FAILED when the query failed, or
ERR_CONNECT_FAILED if a connection with the radio failed.
SetRTSThreshold()
Sets the radio RTS (Request To Send) threshold.
Syntax: UINT SetRTSThreshold( USHORT & );
Parameters: &
References a USHORT value.
Returns: None.
GetRTSThreshold()
Gets the radio RTS threshold.
Syntax: UINT GetRTSThreshold( USHORT & );
Parameters: &
References a USHORT value.
Returns: None.
ConfigureProfile()
If using the Intermec 802.11b Profile Management system, you can program the API to configure the radio to a specific profile by passing the profile name.
Syntax: UINT ConfigureProfile( TCHAR * );
Parameters: Pointer to a string that contains the name of the profile to be activated.
Returns: None.
106
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
StartScanList()
If a scan list is configured, this will start the API looking for a network on
that scan list and configuring the radio appropriately. This call can take a
long time to process.
Syntax: UINT StartScanList( );
Parameters: None.
Returns: None.
802.11b Radio CORE Module
The 802.11b radio CORE module displays helpful information about the
802.11b radio option built into your 700 Series Computer.
Note that you can configure the 802.11b radio module from this CORE
application. Select Configure → Configure 802.11 CF from the bottom
menu bar to access the Profile Wizard application. Information about this
application starts on page 87.
Select Modules → Intermec 802.11 CF Help for more information on
the contents of this CORE module.
General
Below are descriptions and meanings for each piece of information provided via the General tab, reading from top to bottom starting on the left.
S ESS 802.11 Station:
This identifies the type of network to which you are attached, either an
ESS (Embedded Security Subsystem) Station, or Ad-hoc.
S Adapter MAC:
This identifies the MAC address for this 802.11b adapter.
S Scanning:
Status of association. When connected to a network, this changes to
“Connected to NET” with NET being the name of the network to
which you are connected.
700 Series Color Mobile Computer User’s Manual
107
Chapter 4 — Network Support
S Encryption:
This indicates whether WEP encryption is “Enabled” or “Disabled
(Open).” See page 90 for more information.
S Link:
This indicates the speed at which a connection is made.
S TX Power:
This shows the speed (in milliwatts) at which transmissions are made.
S Signal:
This identifies the radio signal strength (in dBm).
S Antenna:
This identifies the antenna being used with the assigned profile.
S AP Mac:
This identifies the MAC address of the access point to which this 700
Series Computer is connected.
S IP:
This provides the IP address which can be set as either DHCP (Dynamic Host Configuration Protocol) or statically.
S Power:
This indicates the power status of this 700 Series Computer: “Always
On” is the default.
S History:
This bar graph displays an active history of this radio module’ s quality
of connections.
S Friendly Indicator:
If the radio stack is loaded, then all three dots are filled. These dots are
left empty if the stack is not loaded. These dots do vary based on the
CORE application’ s perception of the overall connection quality.
108
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
Details
Below are descriptions and meanings for each piece of information provided via the Details tab, reading from top to bottom.
S Attach-Roam Cnt:
This includes the number of new associations made during the current
session, including any found roaming.
S Scanlist:
This indicates whether the Scan List option was enabled or disabled. See
page 97 for more information.
S Watchdog Status:
This monitors the activity of the Scan List: “Running” or “Stopped.”
S Supplicant:
This monitors the 802.1x security activity on the client: “Running” or
“Stopped.”
700 Series Color Mobile Computer User’s Manual
109
Chapter 4 — Network Support
WWAN Radio Options
The 700 Series Computer can integrate either the GSM/GPRS or the
CDMA/1xRTT radio along with the 802.11b radio and the Wireless
Printing option. The WWAN radio option accommodates any Wireless
WAN requirements, such as taking the 700 Series Computer off the premises in a delivery vehicle to cover a much larger area.
GSM/GPRS
The GSM (Global System for Mobile communications) and GPRS (General Packet Radio Service) wireless infrastructure increases voice capacity,
enables personalized “user-aware” services, and creates networking efficiencies to help wireless service providers drive reduced operating costs.
S GSM is an open, nonproprietary system. One of its great strengths is
the international roaming capability. This provides seamless and samestandardized same-number contactability world-wide. GSM satellite
roaming has extended service access to areas with unavailable terrestrial
coverage.
S GPRS is the high-speed data evolution of GSM. GPRS supports Internet Protocol (IP), enabling access to Internet and intranet content and
applications from GPRS wireless devices. The anticipated data rate for
GPRS is 115 Kbps and throughput rates of 30-60 Kbps have been
achieved initially. This high speed capability enables vehicle applications
to become real-time and to use the Internet for access to corporate data
or information in the form of traffic or navigation.
CDMA/1xRTT SB555
Code Division Multiple Access (CDMA) is a form of “spread-spectrum,” a
family of digital communication techniques used in military applications
for years. The core principle of spread-spectrum is the use of noise-like
carrier waves, and, as the name implies, bandwidths much wider than that
required for simple point-to-point communication at the same data rate.
S 1XRTT, the first phase of CDMA2000, is designed to support up to
144 KB per second packet data transmission and to double the voice
capacity of current generation CDMA networks.
S SB555 Embedded Module, from Sierra Wireless, provides complete
wireless functionality and integrates easily into the most compact and
slender mobile applications with its small flexible design. The SB555
offers maximum coverage and access to entire CDMA networks.
110
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
WAN Radio CORE Module
The WAN radio CORE module displays helpful information about either
the GSM/GPRS radio or the CDMA/1xRTT radio option built into your
700 Series Computer. The following illustrations are for a GSM/GPRS
GEM350X radio.
General
Below are descriptions and meanings for each piece of information provided via the General tab, reading from top to bottom starting on the left.
The information applies to both the GSM/GPRS and the CDMA/1xRTT radio modules unless otherwise indicated.
S Network Type:
This is the network type which would list either “GSM-GPRS” or
“CDMA-1XRTT.” Scatternets are not supported.
S IWS (GSM/GPRS) or Sprint PCS Network (CDMA/1xRTT):
This lists the name of the wireless network provider, such as T-Mobile,
Voicestream, AT&T Wireless, etc. “IWS” is short for the Iowa Wireless
Service carrier.
S Registered on home network:
If the WAN radio module has registered with a service provider network, then one of the following will appear:
S Registered on home network:
The radio module is registered on its “home” network.
S Registered on roamed network:
The radio module is registered on another service provider’ s network.
S Radio Not Registered:
There is no network within range of this radio module.
S Radio ESN:
This displays the Electronic Serial Number (ESN) assigned to this radio
module or lists “Unavailable” if a number cannot be read from the radio.
700 Series Color Mobile Computer User’s Manual
111
Chapter 4 — Network Support
S RSSI:
This displays the Received Signal Strength Indicator (RSSI) frequency or
lists “Unavailable” if there is no signal or the signal cannot be retrieved
from the radio module.
S BER (GSM/GPRS GEM 350X, CDMA/1xRTT):
This shows the Bit Error Rate (BER), the percentage of bits with errors
divided by the total number of bits transmitted, received, or processed
over a given period of time.
S f/w:
This identifies the firmware version, if available.
S h/w:
This identifies the hardware version, if available.
S Serial Status:
This indicates whether serial communications passed (“Serial com OK”)
or failed (“Serial com FAIL”) in its last transaction. A status of “Serial
com FAIL” typically indicates that the 700 Series Computer is unable to
establish communication with the radio module installed within.
S Xircom GEM3503 (GSM/GPRS), Siemens MC45 (GSM/GPRS), or
Sierra Wireless SB555 (CDMA/1xRTT):
This identifies the product name for this radio module.
S Band (GSM/GPRS) or Channel (CDMA/1xRTT):
This identifies the bandwidth or channel available for this radio module,
if any.
S History:
This bar graph displays an active history of this radio module’ s quality
of connections.
S Friendly Indicator:
Usually indicates the signal strength for this radio module. Three filled
dots indicate a high quality or strong signal. Three empty dots indicate
that the signal is out of range or there is no signal detected.
112
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
Details
Below are descriptions and meanings for each piece of information provided via the Details tab, reading from top to bottom. Most of this is similar to what is shown under the General tab. The information applies to both
the GSM/GPRS and the CDMA/1xRTT radio modules unless otherwise indicated.
S Serial Status:
This indicates whether serial communications passed (“PASS”) or failed
(“FAIL”) in its last transaction. A status of “FAIL” typically indicates
that the 700 Series Computer is unable to establish communication
with the radio module installed within.
S Manufacturer:
This lists the name of the manufacturer that developed this radio module, such as “Xircom, an Intel Corporation,” “Siemens,” or “Sierra Wireless.”
S Model:
This identifies the product name for this radio module, such as
“SB555,” “GEM350X,” or “MC45.”
S IMEI # (GSM/GPRS):
This is the IMEI (International Mobile station Equipment Identity) serial number of the GSM/GPRS radio module.
S RSSI:
This displays the RSSI frequency or lists “Unavailable” if there is no signal or the signal cannot be retrieved from the radio module.
S Operator:
This lists the name of the service providing the network support.
S SIM Status (GSM/GPRS MC45):
Identifies whether a Subscriber Identity Module (SIM) card is installed
in this 700 Series Computer.
700 Series Color Mobile Computer User’s Manual
113
Chapter 4 — Network Support
S Band (CDMA/1xRTT):
This identifies the frequency bands used by this radio module.
S IMSI # (GSM/GPRS):
This shows the IMSI (International Mobile Subscriber Identity) number
assigned to the SIM card installed in this 700 Series Computer.
S Radio Temp (CDMA/1xRTT):
This identifies the temperature of the radio module, or lists “Unavailable degrees” if there is no information or the temperature cannot be
measured.
S Firmware Rev:
This identifies the firmware version, if available.
S Firmware Date (GSM/GPRS):
This provides the last date when this firmware was updated, if available.
Terminal Application
Tap Terminal App from the Details page to send standard AT commands.
Information about these AT commands are available under “AT Command
Interface” on page 115.
Select an AT command from the drop-down list, then tap Send. The results of each test appears in the text box. Tap Exit or ok to close this screen
and return to the Details page.
114
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
Phone Application
With the WAN radio module installed in your 700 Series Computer, you
can send and receive telephone calls. Use the speaker on the back of the
computer as your earpiece and use the connector on the bottom of the
computer for your mouthpiece.
Tap Phone App from the Details page to access the application which will
process your phone calls. Tap Exit or ok to close this application and
return to the Details page.
S Tap the numbers for a phone call, using Clear to erase each digit, then
tap Send to initiate the call.
S Tap Answer to receive an incoming call.
S Tap End to disconnect a transaction.
S Tap Vol ^ or Vol v to adjust the speaker volume.
S Tap Mic ^ or Mic v to adjust the microphone sensitivity.
AT Command Interface
This interface specification is based on the following recommendation:
S ETSI GSM 07.05:
European Digital Cellular Telecommunication System (phase 2)
Use of DTE-DCE interface for Short message and cell broadcast service.
S ETSI GSM 07.07:
European Digital Cellular Telecommunication System (phase 2)
AT command set for GSM Mobile Equipment.
S ITU-T Recommendation V.25 ter
Serial asynchronous automatic dialing and control.
700 Series Color Mobile Computer User’s Manual
115
Chapter 4 — Network Support
Note: You will need the Adobe Acrobat Reader application to view a PDF
document. Go to “http://www.adobe.com/prodindex/acrobat/readstep.html”
to install or download the latest Adobe Acrobat Reader according to
Adobe’ s instructions.
Command Set for Sierra Wireless SB555
Use the AT command interface from Sierra Wireless to program the
CDMA/1xRTT SB555 radio module. Documentation for this interface is
available via the following URL. Click the “General AT command reference” link for a PDF document, which is 680 KB in size. Note that this
URL is subject to change.
http://www.sierrawireless.com/ProductsOrdering/embedded_docs.html
Command Set for Xircom/Intel GEM350X
Use the GEM350X AT command list from Intel Corporation to program
the GPRS/GSM GEM350X radio module. The “GEM350X Programmer’ s
Reference” is available either from Intermec Technologies or from Intel
Corporation. Contact either your Intermec representative or the Intel Corporation support personnel at the following URL for more information.
Note that this URL is subject to change.
http://support.intel.com/sites/support/index.htm?iid=intelhome1+support&
Command Set for Siemens MC45
Use the MC45 AT command interface from Siemens AG to program the
GPRS/GSM MC45 radio module. The “MC45 Siemens Cellular Engine
AT Command Set” is available either from Intermec Technologies or from
Siemens AG. Contact either your Intermec representative or the Siemens
AG support personnel at the following URL for more information. Note
that this URL is subject to change.
http://www.siemens-mobile.com/btob/CDA/presentation/ap_btob_cda_presentation_fron
tdoor/0,2950,12,FF.html
116
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
Testing the AT Commands
These commands can be sent to either WAN radio by setting up a dial-up
networking connection to COM4. Do the following to initiate this connection and test these commands to your radio:
1 From the 700 Series Computer, select Start → Settings → the
Connections tab → the Connections icon.
2 Tap Modify beneath the Internet Settings drop-down list.
3 Tap New.. to make a new connection.
700 Series Color Mobile Computer User’s Manual
117
Chapter 4 — Network Support
4 Enter a name for the connection, select “WANA on COM4” from the
Select a modem drop-down list, and select “115200” from the Baud
rate drop-down list. Tap Advanced to continue.
5 On the Port Settings tab, check Enter dialing commands manually,
then tap ok, Next, then Finish to return to the Internet Settings screen
with your new connection.
118
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
6 Press and hold the new connection for a pop-up menu, then tap
Connect to initiate the connection. Wait for about ten seconds for the
Network Log On screen, then tap OK. Note: You do not need to enter any
information within the Network Log On screen.
7 Use either the onscreen keyboard, or press the keys to type any of the
AT commands provided by Sierra Wireless. Press or tap Enter to send
each command. The results of each command sent will print onscreen see the sample illustration below. Note that each “AT” command must
start with either the “at” or “at+” characters.
S To see what you typed onscreen, type “ate1” to initiate the AT Echo
command, then press Enter.
700 Series Color Mobile Computer User’s Manual
119
Chapter 4 — Network Support
Wireless Printing
The 700 Series Computer can integrate the Wireless Printing option
(which is equipped with a Bluetooth qualified module by Socket Communications) along with either the GSM/GPRS or the CDMA/1xRTT radio and
the 802.11b radio. This option uses the network to print information
stored on the 700 Series Computer.
“Bluetooth” is the name given to a technology standard using short-range
radio links, intended to replace the cables connecting portable and fixed
electronic devices. The standard defines a uniform structure for a wide
range of devices to communicate with each other, with minimal user effort. Its key features are robustness, low complexity, low power, and low
cost. The technology also offers wireless access to LANs, the mobile phone
network, and the internet for a host of home appliances and portable
hand-held interfaces.
Documentation
Information about additional “Bluetooth” software, including the Bluetooth Device Manager and the BTctrl program, can be found within the
Wireless Printing SDK. This is located on the 700C Software Tools CD,
via the directory off the root of the toolkit called “Wireless Printing SDK.”
It also can be found in the Wireless Printing Development Guide, also on the
700C Tools CD.
Bluealps CORE Module
The Bluealps CORE module displays helpful information about this Wireless Printing option within your 700 Series Computer. Below are descriptions and meanings for each piece of information provided via the General
tab, reading from top to bottom starting on the left.
120
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
S Bluetooth Point to Point:
This is the network type. “Point to Point” is the type of connection supported as of this publication. Scatternets are not supported. The only supported application is wireless printing to Intermec wireless printers, such
as the 781T Belt-Mount Printer.
S Device Address:
This provides the network address, which in this case, will be replaced
by the device address of the Bluetooth compatible module within your
700 Series Computer. Note that this address is universally unique.
S Discoverable:
The following is displayed depending on whether the 700 Series Computer is configured to be discoverable:
“Gen” Generally discoverable
“Lim” Limited discovery
“No”
Not discoverable
S Connectable:
This defines whether the 700 Series Computer is able to accept other
devices with Bluetooth compatible modules connecting to it. “Yes” if the
connection is doable, “No” if not.
S Bondable:
This defines the security element of the 700 Series Computer, which is
the bondable setting. If the unit is bondable, then “Yes” is displayed,
otherwise “No” is displayed.
S Module Firmware:
This reflects the firmware (hardware) version of the 700 Series Computer. When the CORE module first installs onto the unit, the firmware
level is unknown, thus “...reading” is displayed. Once the firmware level
is read from the unit, then a three-digit decimal is displayed.
S Stack [Stack Version] [loaded/not loaded]:
[Stack Version] displays the Bluetooth stack version, which appears in the
“1.2.3.4” format. If the stack is loaded, then “loaded” is displayed after
the stack version, otherwise “not loaded” is displayed.
S Device Name:
This displays the device name as assigned to the Bluetooth compatible
module by the end-user. If the configured name is longer than the space
allowed, it will be truncated.
S BTpak Version:
This displays the driver version of additional Bluetooth components
within the 700 Series Computer and is usually presented in the “1.2.3”
format. The version may also contain a letter at either end.
S History:
This bar graph displays an active history of this wireless printer driver’ s
quality of connections.
S Friendly Indicator:
If the Bluetooth stack is loaded, then all three dots are filled. These dots
are left empty if the stack is not loaded. These dots do vary based on the
CORE application’ s perception of the overall connection quality.
700 Series Color Mobile Computer User’s Manual
121
Chapter 4 — Network Support
AutoIP/DHCP
Automatic Private IP Addressing (AutoIP) is enabled by default in Pocket
PC 2002. To remain compatible with other Pocket PC devices, this setting
needs to be enabled. You can configure the registry settings in the
following to set the required AutoIP/DHCP behavior:
S For Ethernet:
HKEY_LOCAL_MACHINE\Comm\LAN9001\TcpIp
S Fot 802.11b:
HKEY_LOCAL_MACHINE\Comm\NETWLAN1\TcpIp
Other registry keys that can modify the behavior of AutoIP are as follows.
You can find the appropriate settings and behavior of each of these keys in
Microsoft Help.
S AutoInterval
S AutoMask
S AutoSubnet
S AutoIP
S AutoSeed
When a TCP/IP client cannot find a DHCP server, it generates an AutoIP
address from the 169.254.xxx.xxx block. The client then tries to check for
a DHCP server every 300 seconds (5 minutes) and if a DHCP server is
found, the client drops the AutoIP address and uses the address from the
DHCP server.
In the MSDN Windows CE documentation, see “Automatic Client Configuration” for more information on AutoIP.
To disable AutoIP, set the AutoCfg registry entry to “0.” If a DHCP server
cannot be found, instead of using AutoIP, the system will display the “Unable to obtain a server assigned IP address” message.
Note: If AutoIP is defined using CAB files, the EnableDHCP registry key
must also be defined and set to “1” before the system will attempt to obtain a DHCP address.
To extend the number of attempts that a DHCP client makes to get a
DHCP address, use the DhcpRetryDialogue and DhcpMaxRetry registry
settings.
Change the AutoInterval registry key value to make the client retry more
often to obtain a DHCP address.
122
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
SNMP Configuration
Simple Network Management Protocol (SNMP) was developed in the late
1980s to provide a general-purpose internetworking management protocol.
Its primary goal was to be simple so nothing would stand in the way of its
ubiquitous deployment. To this end, it has been very successful as it is currently deployed in almost every major internetworking product on the
market. However, like many achieved goals, the primary strength can also
become a weakness.
The Focus was “Simple”
An extreme example of simplicity versus power can be realized by comparing SNMP against the Common Management Information Protocol
(CMIP), the ISO entry to the standard management protocol world.
CMIP has a very rich set of primitives and a core set of data elements.
However, to implement CMIP, a subset of the protocol must be selected.
Then, to achieve interoperability, this subset must be agreed upon with
other implementors. As SNMP was specified completely and with no options, one implemented what was there and interoperability was assured.
Returning to simplicity, SNMP was built simply for a number of reasons
other than time to market: robustness in the face of network failure, low
overhead in the devices running the protocol; and ease of debugging the
protocol itself (the last thing you want to debug is the management protocol
that is supposed to be helping you debug your network). Thus, the SNMP
limited itself to the User Datagram Protocol (UDP). This gave the
implementor the ability and responsibility to manage lost packets and
perform any necessary retransmissions. As network debugging in the face
of changing routes will certainly mean losing packets, retaining this control
from the transport service (layer 4) was considered essential. Since a
network management protocol will run continuously, it is mandatory that
it consume as minimal a network resource as possible. UDP allows the
necessary control over packet transmissions, packet size and content
(packetization). It is a natural choice.
Using SNMP
SNMP has three control primitives that initiate data flow from the
requester (get, get-next, and set). There are two control primitives the
responder uses to reply. One is used in response to the requester’ s direct
query (get-response) and the other is an asynchronous response to obtain
the requester’ s attention (trap). All five of these primitives are carried by
UDP and are thus limited in size by the amount of data that can fit into a
single UDP packet. The relatively small message size was a goal of the
design but for some reasonable set of network management functions, it
imposes a limitation.
Often in network management, it is necessary to obtain bulk information
without knowing at first what is in that bulk. In one case, there is a set of
problems having to do with packets not going where they are supposed to,
due to device misconfiguration that prevents proper protocol operation
where one needs to view the entire set of data.
700 Series Color Mobile Computer User’s Manual
123
Chapter 4 — Network Support
Retrieval of Management Information
SNMP has the get-next primitive which permits the viewing of data
without requiring prior knowledge. If you know what you are looking for,
the get primitive will return it. When you want an entire table of
information, the get-next primitive will obtain it. However, unless
employed with care, the get-next primitive can be extremely
resource-intensive in real time, network bandwidth, and the agent’ s CPU
time. The simplest use of the get-next primitive is to start at the beginning
of a table, await the response and then issue another get-next with the
name returned. As an example, say you wanted the next-hop address,
next-hop interface, and route-type from a routing table containing 1000
entries. Using the simplest form of get-next, this would require 2x3x1000
or 6000 packets (get-next and get-response packets, columns, and rows). A
straight-forward optimization would be to request the three columns in a
single packet. This puts the number of packets at 2x1000 or 2000 packets.
In real time, it is the product of the round trip by the number of request.
In agent CPU time, this is still 6000 lookups in the routing table for both
cases.
An Early Approach to Getting More than One Item at a Time
The ability to retrieve only one piece or object at a time has been a
problem for SNMP. This is particularly an issue with the use of this
protocol in wireless environments where the wireless datapipe is small and
overhead due to network management it is considered overhead. One
approach creates multiple get-next requests running concurrently. A second
algorithm, reduces the packet count by combining the multiple concurrent
get-nexts into a single packet. Neither approach has been implemented
which makes network management in wireless environment, though
essential to the success of the operation, tenuous. The issue has been
resolved in SNMP V2 protocol where a get-bulk primitive has been
defined.
Conclusion
Software development moves forward by evolving the unknown into the
known and wireless environments are moving from vertical only
application to wide spread implementation. At the time of the SNMP
inception, it was not possible to conceive of a reliable transport based
network management protocol. Today’ s problems require more
sophisticated data to analyze a problem. This puts the burden back on the
protocol to send and receive data quickly and efficiently. Work continues
in subcommittees to improve SNMP and resolve the issues that are
developing with new applications and new network architectures.
124
700 Series Color Mobile Computer User’s Manual
Chapter 4 — Network Support
SNMP Configuration on the 700 Series Computer
In short, SNMP is an application-layer protocol that facilitates the exchange of management information between network devices. The 700
Series Computer is such an SNMP-enabled device. Use SNMP to control
and configure the 700 Series Computer anywhere on an SNMP-enabled
network.
The 700 Series Computer supports four proprietary Management Information Bases (MIBs) and Intermec Technologies provides SNMP support
for MIB-II through seven read-only MIB-II (RFC1213-MIB) Object
Identifiers (OIDs).
Note: You can only query these seven OIDs through an SNMP management station, these are not available in the Unit Manager applications.
Management Information Base
The Management Information Base is a database that contains information
about the elements to be managed. The information identifies the management element and specifies its type and access mode (Read-Only, ReadWrite). MIBs are written in ASN.1 (Abstract Syntax Notation.1) - a machine independent data definition language. Note: Elements to be managed
are represented by objects. The MIB is a structured collection of such objects.
You will find the following MIB files either on the 700C Tools CD or on
the web via http://www.intermec.com:
S INTERMEC.MIB
Defines the root of the Intermec MIB tree.
S ITCADC.MIB
Defines objects for Automated Data Collection (ADC), such as bar code
symbologies.
S ITCSNMP.MIB
Defines objects for Intermec SNMP parameters and security methods,
such as an SNMP security IP address.
S ITCTERMINAL.MIB
Defines objects for 700 Series parameters, such as key clicks.
700 Series Color Mobile Computer User’s Manual
125
Chapter 4 — Network Support
Object Identifiers
Each object has a unique identifier called an OID. OIDs consist of a sequence of integer values represented in dot notation. Objects are stored in
a tree structure. OIDs are assigned based on the position of the object in
the tree. Seven MIB OIDs are shown in the followig table.
Example
The internet OID = 1.3.6.1.
MIB Object Identifiers
MIB-II Item
OID
Group or Table
Description
ifNumber
1.3.6.1.2.1.2.1.0
Interfaces Group
Indicates the number of adapters
present in the system. For the 700
Series Computer, if one adapter is
present in the system, then ifNumber = 1 and ifIndex = 1.
ifIndex
1.3.6.1.2.1.2.2.1.1.ifIndex
Interfaces Table (ifTable)
A unique value for each interface.
The value ranges between 1 and the
value of ifNumber.
ifDescr
1.3.6.1.2.1.2.2.1.2.ifIndex
Interfaces Table (ifTable)
A textual string containing information about the interface.
ifType
1.3.6.1.2.1.2.2.1.3.ifIndex
Interfaces Table (ifTable)
An integer containing information
about the type of the interface. It is
equal to 1 for Other.
ipAdEntAddr
1.3.6.1.2.1.4.20.1.1.IpAddress IP address Table
(ipAddrTable)
The IP address to which this entry’ s
addressing information pertains
(same as 700 IP address), where IP
Address is the valid non-zero IP address of the 700 Series Computer.
ipAdEntIfIndex
1.3.6.1.2.1.4.20.1.2.IpAddress IP address Table
(ipAddrTable)
The index value that uniquely identifies the interface to which this
entry is applicable (same as ifIndex).
ipAdEntNetMask
1.3.6.1.2.1.4.20.1.3.IpAddress IP address Table
(ipAddrTable)
The subnet mask associated with
the IP address of this entry (same as
Subnet Mask).
Configuring with SNMP
The community string allows an SNMP manager to manage the 700 Series
Computer with a specified privilege level. The default read-only community string is “public” and “private” is the default read/write community
string. See the specific configuration parameter to find its OID. To configure the 700 Series Computers using SNMP:
1 Configure 700 Series Computers for RF or Ethernet communications.
2 Determine the OID (Object Identifier) for the parameter to be changed. The Intermec base OID is 1.3.6.1.4.1.1963.
3 Use your SNMP management station to get and set variables that are
defined in the Intermec MIBs. You can set the traps, identification, or
security configuration parameters for SNMP. See Appendix A, “Control
Panel Applets,” to learn more about these parameters.
126
700 Series Color Mobile Computer User’s Manual
5
Printer Support
The 700 Series Color Mobile Computer works with the following printers
from Intermec Technologies. Contact an Intermec Representative for information about these printers.
S 6820
A full-page, 80-column printer.
S 6808
A 4-inch belt-mount printer.
S 781T
A 2-inch belt-mount printer with a Bluetooth compatible module from
Socket Communications.
S 782T
A 2-inch workboard printer.
700 Series Color Mobile Computer User’s Manual
127
Chapter 5 — Printer Support
Printing ASCII
The following methods for printing using Pocket PC at this time is as follows:
S Add port drivers to print ASCII directly to the port.
S Use LinePrinter ActiveX Control from the Software Developer’ s Kit
(SDK) - see the SDK User’ s Manual for more information.
S Via wireless printing - see the Wireless Printing Development Guide on the
700C Software Tools CD for more information.
Directly to a Port
Printing directly to the port sends RAW data to the printer. The format of
this data depends upon your application and the printer capabilities.
You must understand the printer commands available for your specific
printer. Generally, applications just send raw ASCII text to the printer.
Since you are sending data to the printer from your application directly to
the port you are in complete control of the printers operations. This allows
you to do line printing (print one line at a time) rather than the page format printing offered by the GDI approach. It is also much faster since data
does not have to be converted from one graphics format to the other (display to printer). Most Intermec printers use Epson Escape Sequences to
control print format operations.
These commands are available in documentation you receive with your
printers or from technical support. Win32 APIs are required to print directly to the port.
Directly to a Generic Serial Port
To print directly to a generic serial port printer (non-Intermec printers):
S Use CreateFile() to open ports - COM1: can be opened on most devices.
S Use WriteFile() to send data directly to the printer.
S Use CloseHandle() when you are finished printing to close the port.
IrDA Printer Driver
IrDA printing is only available on the certain devices and is supported directly by the Windows CE load via the IrSock API provided by the Microsoft Win32 API without need for additional drivers. Intermec 6804, 6805,
6806, 6808 and 6820 and other IrDA printers are supported.
128
700 Series Color Mobile Computer User’s Manual
Chapter 5 — Printer Support
NPCP Printer Driver
The NPCP printer communications driver (NPCPPORT.DLL) is a
Stream Device Driver built into the operating system. The driver supports
only NPCP communications to and from the 6820 and 4820 printers over
a selected serial port.
All applications use WIN32 API functions to access the drivers. Basic operations are easily implemented by applications through the CreateFile(),
WriteFile(), ReadFile(), DeviceIOControl(), and CloseHandle() Win32
APIs.
Operations to upgrade printer modules, perform printer diagnostics, and
get printer configuration are performed largely via DeviceIOControl()
functions.
About NPCP
NPCP (Norand Portable Communications Protocol) is a proprietary protocol that provides session, network, and datalink services for Intermec
mobile computers in the Intermec LAN environment used with printers
and data communications.
NPCP Driver Installation and Removal
Use LPT9: for the NPCP printer device and COM1 for the last parameter.
COM1 is the connection available via the 700 Series Computer.
Applications use the RegisterDevice() function to install the driver.
DeregisterDevice() uninstalls the device driver and frees memory space
when the driver is not required. Use the HANDLE returned by
RegisterDevice() as the parameter to DeregisterDevice().
Use the RegisterDevice() function call as demonstrated below. Specify the
full path name to the driver starting at the root for the RegisterDevice()
function to work properly. The last parameter to RegisterDevice() is a
DWORD that represents the name of the port for the NPCP stream driver
to use. Build this parameter on the stack if it is not to be paged out during
the call. The first parameter “LPT” (Device Name) and the second
parameter “9’ (index), indicate the name of the registered device, such as
LPT9. This is used in the CreateFile() function call.
Install()
HANDLE hDevice;
TCHAR port[6];
port[0] = TCHAR(‘C’);
port[1] = TCHAR(‘O’);
port[2] = TCHAR(‘M’);
port[3] = TCHAR(‘1’);
port[4] = TCHAR(‘:’);
port[5] = TCHAR(0);
hDevice = RegisterDevice ( (TEXT(”LPT”), 9,
TEXT(“\\STORAGE CARD\\WINDOWS\\NPCPPORT.dll”), (DWORD)port);
700 Series Color Mobile Computer User’s Manual
129
Chapter 5 — Printer Support
Opening the NPCP Driver
The application opens the NPCP driver by using the CreateFile()
function. The call can be implemented as follows. The first parameter
“LPT9:” must reflect the device name and index used in the
RegisterDevice() function call and will fail for any of the following reasons:
hFile = CreateFile(_T(”LPT9:”), GENERIC_WRITE |
GENERIC_READ, 0, NULL, OPEN_ALWAYS, FILE_ATTRIBUTE_NORMAL,
NULL);
S The port associated with the device during RegisterDevice() is in use.
S The NPCP device is already open.
S The share mode is not set to zero. The device cannot be shared.
S Access permissions are not set to GENERIC_WRITE |
GENERIC_READ. Both modes must be specified.
Closing the NPCP Driver
Using the CloseHandle() (hFile) function closes the NPCP driver. Where
hFile is the handle returned by the CreateFile() function call.
S TRUE = the device is successfully closed.
S FALSE = an attempt to close NULL HANDLE or an already closed device.
Reading from the NPCP Driver
Reading of the NPCP printers is not supported since all responses from the
printer are the result of commands sent to the printer. DeviceIoControl()
functions are provided where data is to be received from the printer.
Writing to the NPCP Driver
All Print data can be sent to the printer using the WriteFile() function.
The print data written to the driver must contain the proper printer
commands for formatting. If the function returns FALSE, the NPCP error
may be retrieved using IOCTL_NPCP_ERROR. See the description on
the next page.
130
700 Series Color Mobile Computer User’s Manual
Chapter 5 — Printer Support
NPCP Driver I/O Controls
An application uses the DeviceIoControl() function to specify an printer
operation to be performed. Certain I/O controls are required to bind and
close communication sessions with the printer, and must be completed
before any other commands to the driver can execute properly.
The function returns TRUE to indicate the device successfully completed
its specified I/O control operation, otherwise it returns FALSE. The
following I/O control codes are defined:
#define IOCTL_NPCP_CANCEL
CTL_CODE(FILE_DEVICE_SERIAL_PORT,0x400,METHOD_BUFFERED,FILE_ANY_ACCESS)
#define IOCTL_NPCP_BIND
CTL_CODE(FILE_DEVICE_SERIAL_PORT,0x401,METHOD_BUFFERED,FILE_ANY_ACCESS)
#define IOCTL_NPCP_CLOSE
CTL_CODE(FILE_DEVICE_SERIAL_PORT,0x402,METHOD_BUFFERED,FILE_ANY_ACCESS)
#define IOCTL_NPCP_ERROR
CTL_CODE(FILE_DEVICE_SERIAL_PORT,0x403,METHOD_BUFFERED,FILE_ANY_ACCESS)
#define IOCTL_NPCP_FLUSH
CTL_CODE(FILE_DEVICE_SERIAL_PORT,0x404,METHOD_BUFFERED,FILE_ANY_ACCESS)
#define IOCTL_NPCP_IOCTL
CTL_CODE(FILE_DEVICE_SERIAL_PORT,0x405,METHOD_BUFFERED,FILE_ANY_ACCESS)
#define IOCTL_NPCP_PRTVER
CTL_CODE(FILE_DEVICE_SERIAL_PORT,0x406,METHOD_BUFFERED,FILE_ANY_ACCESS)
S IOCTL_NPCP_CANCEL
This cancels all printing at the printer. It flushes the printer buffers and
reinitializes the printer to its default state. No parameters are required.
S IOCTL_NPCP_BIND
This command is required before any data is sent or received by the
printer. Once the driver is opened, the application must bind the communications session with the printer before any data can be sent or received by the printer. If an error occurs during the bind, the application
may use IOCTL_NPCP_ERROR to get the current extended error
code. No parameters are required.
S IOCTL_NPCP_CLOSE
This command closes the current session with the printer. This function
always returns TRUE. No parameters are required.
S IOCTL_NPCP_ERROR
This command returns the extended NPCP error code in PL/N format.
The word returned will contain the PL/N compatible error code in the
low byte and completion flags in the high byte. If the frame that returned an error was not received correctly by the printer the
FRAME_NOT_ACKED bit will be set in the high byte. This operation
always returns TRUE. An output buffer of at least 2 bytes is required.
See “NPCP Error Codes” on page 133.
S IOCTL_NPCP_FLUSH
This command allows the application to poll the printer for errors while
the report is completing the print process at the printer. If an error occurs during the polling process, the operation will return FALSE and the
application can get the extended error code by using
IOCTL_NPCP_ERROR. No parameters are required.
700 Series Color Mobile Computer User’s Manual
131
Chapter 5 — Printer Support
NPCP Printer Communications
All NPCP printer communications should be based on the following flow:
1 Use CreateFile(); to open the printer driver.
2 Use IOCTL_NPCP_BIND to bind a session with the printer;
IOCTL_NPCP_ERROR to check for errors on the bind to ensure success; and IOCTL_NPCP_CANCEL to cancel any outstanding print
jobs.
3 Use IOCTL_NPCP_FLUSH to poll the printer to free up printer buffer resources. Use IOCTL_NPCP_FLUSH to poll the printer’ s status. If
an error is reported by the IOCTL, then use IOCTL_NPCP_ERROR
to get the error and determine the correct recovery procedure.
4 Use WriteFile(); to write your data to the printer. Check for errors and
that all data were written. Use IOCTL_NPCP_ERROR to get the extended error. If the error is critical in nature, use
IOCTL_NPCP_CLOSE, followed by CloseFile(), to end the communications session. Start a new session, beginning with step 1 to ensure
proper printing. For noncritical errors display the error and retry the
operation.
5 After all data is sent to the printer, ensure that the printer continues to
print the report properly by polling the printer’ s status. Use
IOCTL_NPCP_FLUSH to poll the printer’ s status. If an error is reported by the IOCTL, then use IOCTL_NPCP_ERROR to get the error and determine the correct recovery procedure.
Sample Code
See sample code in the “\700 Color Dev Tools\Installable Drivers\Port
Drivers\Npcp\NPCPPrint\” directory for more details on printing, printer
communications and error code handling.
132
700 Series Color Mobile Computer User’s Manual
Chapter 5 — Printer Support
NPCP Error Codes
Call the IOCTL_NPCP_ERROR I/O control function to receive PL/N
compatible error codes. Applications must decide how to act upon the data
returned.
// Definition of NPCP communications Errors and Printer Errors
#define PNRDY (BYTE)102 // link not ready error
#define RXTMO (BYTE)104 // link no receive error
#define TXTMO (BYTE)106 // link no transmit error
#define BADADR (BYTE)111 // frame address error
#define GAPERR (BYTE)112 // link gap error (timeout) in receive data
#define LSRPE (BYTE)113 // frame parity error on length field
#define IFTS (BYTE)120 // session layer - invalid frame this state
#define NS_NE_VR (BYTE)121 // session layer sequence error
#define NR_NE_VS (BYTE)122 // session layer sequence error
#define MAC_CRCERR (BYTE)124 // MAC CRC error
#define RLENERR (BYTE)123 // MAC too much data received
#define FRMERR (BYTE)200 // Frame Reject
#define FRMERR_IF (BYTE)201 // Frame Reject - Invalid Frame
#define FRMERR_NR (BYTE)202 // Frame Reject - NR Mismatch
#define FRMERR_NS (BYTE)203 // Frame Reject - NS Mismatch
#define NDMERR (BYTE)204 // Normal Disconnect mode error
#define BINDERR (BYTE)210 // bind error
#define IPLDUR (BYTE)221 // invalid presentation layer response
#define HEADJAM (BYTE)222 // printer head jam
#define PAPEROUT (BYTE)223 // printer paper out
#define LOWVOLTS (BYTE)224 // printer low voltage
#define HIVOLTS (BYTE)225 // printer over voltage
#define LOWBAT (BYTE)226 // printer low battery
#define COVEROFF (BYTE)227 // printer cover off error
#define HEADFAULT (BYTE)228 // printer head short or driver short error
#define PFFAULT (BYTE)229 // paper feed motor fault.
#define FRAME_NOT_ACKED 0x8000 // frame was not received by printer and need to
be resent.
700 Series Color Mobile Computer User’s Manual
133
Chapter 5 — Printer Support
O’ Neil Printer Driver
The DTR printer communications driver is a Stream Device Driver
named ONEIL.DLL.
All applications use WIN32 API functions to access drivers. Basic
operations are easily implemented by applications through the CreateFile(),
WriteFile(), DeviceIOControl() and CloseHandle() Win32 APIs.
The driver supports communications to 6804DM, 6804T, 6805A, 6806,
6808, 681T, and 781 printers over a selected serial port.
DTR Driver Installation and Removal
Your application must install the device driver by using the RegisterDevice() function. The driver name is ONEIL.DLL. We recommend that
you use “DTR” for the Device Name parameter, “1” for the Device Driver
index parameter, and use any of the following strings for the last parameter:
S NULL (==0) Defaults to COM1 @ 9600
S “COM1” only COM port specified defaults to 9600
S “COM1:9600” sets to COM port and specified bit rate
S “COM1:19200” sets to COM port and specified bit rate
Use the HANDLE returned by RegisterDevice() as the parameter to
DeregisterDevice(). The correct usage of the RegisterDevice() function call
is demonstrated below. You may use DeregisterDevice() to uninstall the
driver.
Install()
HANDLE hDevice;
TCHAR port[6];
port[0] = TCHAR(‘C’);
port[1] = TCHAR(‘O’);
port[2] = TCHAR(‘M’);
port[3] = TCHAR(‘1’);
port[4] = TCHAR(‘:’);
port[5] = TCHAR(0);
hDevice = RegisterDevice ( (TEXT(”DTR”), 1, TEXT(”\\WINDOWS\\ONEIL.DLL”),
(DWORD)port);
134
700 Series Color Mobile Computer User’s Manual
Chapter 5 — Printer Support
Opening the DTR Driver
The application opens the DTR driver by using the CreateFile() function.
The call can be implemented as follows:
hFile = CreateFile(_T(”DTR1:”), GENERIC_WRITE, 0, NULL,
OPEN_ALWAYS, FILE_ATTRIBUTE_NORMAL, NULL);
The first parameter “DTR1:” must reflect the device name and index used
in the RegisterDevice() function call.
The function call will fail for any of the following reasons:
S The port associated with the device during RegisterDevice() is currently
in use.
S The DTR device is already open.
S The share mode is not set to zero. The device cannot be shared.
S Access permissions are not set to GENERIC_WRITE.
Closing the DTR Driver
Using the CloseHandle() (hFile) function closes the DTR driver. Where
hFile is the handle returned by the CreateFile() function call.
S TRUE indicates the device is successfully closed.
S FALSE indicates an attempt to close a NULL HANDLE or an already
closed device.
Writing to the DTR Driver
You can use the WriteFile() function to send all Print data to the printer.
The print data being written must contain the proper formatting printer
commands.
DTR Printer Communications
All DTR printer communications should be based on the following flow:
1 Use CreateFile(); to open the printer driver.
2 Use WriteFile() to write your data to the printer. Check for errors and
that all data were written.
3 Use CloseHandle() to close the driver.
700 Series Color Mobile Computer User’s Manual
135
Chapter 5 — Printer Support
136
700 Series Color Mobile Computer User’s Manual
6
Scanner Support
The 700 Series Color Mobile Computer is available with imaging or laser
scanning technologies, including the following:
S APS linear imager:
Reads 1D symbologies and PDF 417 bar codes. Linear imaging using
Vista Scanning technology reads low-contrast bar codes, laminated bar
codes, and bar codes displayed on CRT or TRT displays. This imaging
uses harmless LEDs for illumination and does not require any warning
labels. Vista Scanning is more reliable than lasers as it is a completely
solid state with no moving parts or oscillating mirrors.
S 2D Imager:
This decodes several stacked 1D and 2D symbologies, including PDF
417 and Data Matrix without “painting.” It can also read 1D codes
from any orientation, for example the scan beam does not need to be
aligned perpendicular to the symbol in order to read it. Photography is a
secondary application; the lens in the device will favor bar code reading.
Photos are 640x480, 256 gray-scale.
S 1D laser scanner:
Traditional laser scanner that decodes 1D bar codes.
S PDF 417 laser scanner:
Higher speed laser scanner that can read PDF 417 labels by “painting”
the label.
700 Series Color Mobile Computer User’s Manual
137
Chapter 6 — Scanner Support
Scanner Control and Data Transfer
Note: To use the methods described below, enable Data Collection functionality on the 700 Computer using the bootloader configuration menu.
See Chapter 3, “Installing Applications” for more information.
The Data Server and associated software provide several ways to manipulate scanner control and data transfer between the scanner subsystem and
user applications:
S Automatic Data Collection COM Interfaces:
These COM interfaces allow user applications to receive bar code data,
and configure and control the bar code reader engine.
S ITCAxBarCodeReaderControl functions:
These ActiveX controls allow user applications to collect bar code data
from the scanner, to configure the scanner, and to configure audio and
visual notification when data arrives. For more information, see the
SDK User’ s Manual.
S ITCAxReaderCommand functions:
Use these ActiveX controls to modify and retrieve configuration information using the reader interface commands. For more information, see
the SDK User’ s Manual.
S Scanning EasySet bar code labels:
You can use the EasySet bar code creation software from Intermec
Technologies Corporation to print configuration labels. Scan the labels
to change the scanner configuration and data transfer settings.
Automatic Data Collection COM Interfaces
Data collection configuration and functionality cannot be accessed by any
means (including control panel applets or remote management applications)
until after the 700 Series Computer has completed initialization, which
occurs during a warm- or cold-boot or after a firmware upgrade.
When initialization is complete, the green LED on the 700 Series Computer stops flashing. Changes made to configuration settings remain after a
warm boot. After a cold-boot, all configuration settings are reset to their
defaults with the exception of scanner configurations, which remain except
for the Symbology Identifier transmission option or the Preamble and
Postamble strings. To reset all configuration settings to the factory defaults,
the S9C scanner firmware must be reloaded.
138
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
The Automatic Data Collection (ADC) functions are accessed through
custom COM interfaces. These interfaces allow the application to receive
bar code data and configure and control the bar code reader engine. The
COM interfaces include the following functions:
S IADC (starting on page 151)
S IBarCodeReaderControl (starting on page 159)
S IS9CConfig (starting on page 172)
S IS9CConfig2 (starting on page 204)
S IS9CConfig3 (starting on page 216)
S IImage Interface (starting on page 221)
Multiple ADC COM Object Support
A 700 Series Computer may have multiple reader engines to decode different types of ADC data. For example, a bar code reader engine decodes raw
bar code data and passes it to a bar code reader COM object. An RFID
reader engine decodes raw RFID tag data and passes it to an RFID tag
reader COM object.
ADC COM interfaces are implemented as in-process COM objects. An
instance of the ADC COM object creates a logical connection to access or
control the reader engine. Specifically, the IBarCodeReadConfig or IBarCodeReaderControl COM objects can manage the bar code scanner configuration while the ADC COM object can gather data simultaneously.
These ADC COM objects or connections can be created in a single application or multiple applications. Up to seven instances of a COM object
can be created for a reader engine. For more information, see “How to
Create and Use the ADC COM Interfaces” below.
For data collection features, ADC COM objects also provide for read
ahead and non-read ahead data access and grid data editing.
700 Series Color Mobile Computer User’s Manual
139
Chapter 6 — Scanner Support
How to Create and Use the ADC COM Interfaces
You can also use the Input Device Functions (starting on page 149) to
create and use the ADC COM interfaces.
1 Create and initialize the in-process Bar Code Reader object using
ITCDeviceOpen() (see page 149). This function returns a COM
Interface pointer to the Bar Code Reader Object created by the
function.
2 Set the data grid if data filtering is desired (default grid gives the application all the data). Below is a sample code of how to set the grid to accept
Code 39 data that starts with the letter “A” and is not a reader command.
ITC_BARCODEREADER_GRID stBCGrid;
stBCGrid.stDIGrid.szDataMask = TEXT(”A%s”);
stBCGrid.stDDGrid.dwSymbologyMask = BARCODE_SYMBOLOGY_CODE39;
stBCGrid.dwDataSourceTypeMask = ITC_DATASOURCE_USERINPUT;
HRESULT hrStatus = pIBCControl->SetAttribute(
ITC_RDRATTR_GRID,
reinterpret_cast(&stBCGrid),
sizeof(stBCGrid)
);
3 Issue a read to accept the bar code data. The timestamp, symbology, and
data type are put into the ITC_BARCODE_DATA_DETAILS structure. Passing in a pointer to this structure is optional. The following
sample code uses an infinite timeout.
ITC_BARCODE_DATA_DETAILS stBCDetails;
BYTE rgbBCData[1024]; // Buffer used to accept the bar code data
DWORD dwBytesReceived; // Number of bytes in the return data.
HRESULT hrStatus = pIBCControl->Read(
rgbBCData,
sizeof(rgbBCData),
&dwBytesReceived,
& stBCDetails,
INFINITE
);
4 Compile and link the application.
Read-Ahead Bar Code Data Access
The Bar Code Reader COM object delivers ADC data to the connection
in read-ahead mode. In this mode, the data is queued until a COM connection is ready to read it. Read-ahead mode decouples reader device performance from the application performance. That is, data is read as fast as
the user can scan it, independent of the connection processing load. No
data will be scanned until the first Read() function is posted.
140
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Grid Data Filtering
The virtual wedge retrieves scanned Automatic Data Collection (ADC)
data and sends it to the keypad driver so that the 700 Series Computer can
receive and interpret the data as keypad input. The data can be filtered so
that only data conforming to a certain text pattern or symbology will be
sent to an application. After the data is filtered, it can be edited by adding,
deleting, or rearranging portions of the text or by extracting portions of
text for further editing. To filter and edit data, you need to define the
virtual wedge grid parameters.
S Grid Processing:
Grid processing takes place in two steps:
S Compilation:
In which the user’ s grid expressions are checked for errors and
reduced to a binary form for faster matching. This is done whenever
the virtual wedge grid is set or changed by configuration software.
S Matching:
In which data is tested against the grids set in compilation. Matching
can be performed multiple times after a compilation. The AIM
symbology ID of the data being tested, including the enclosing angle
brackets, must be prepended to the incoming data.
Syntax
The basic syntax of each grid expression is:
 filter-expression= > editing-expression
where:
S symID
Is the AIM symbology ID (see the AIM Symbology ID Defaults table
starting on page 219).
S filterexpression
Is any character string that includes valid filter expression values (see
the “Filter Expression Values” table on the next page).
S editing-expression
Is any character string that includes valid editing expression values (see
the “Editing Expression Values” table on page 144).
700 Series Color Mobile Computer User’s Manual
141
Chapter 6 — Scanner Support
Filter Expression Values
A filter-expression can be any string of text containing the operators listed
below.
Filter Expression Values
Operator
Meaning
Example
Any character string not containing
the special characters: . ? [ ] { } or \
(period, question mark, left/right
brackets, left/right curly brackets, backslash).
Match the string literally.
super20 matches super20
\c where c is any of the special characters: . ? [ ] { } or \
(period, question mark, left/right
brackets, left/right curly brackets, backslash)
Remove any special meaning of c.
\* matches *
. (period)
Any character.
. matches x
^ (tarot)
Anchor the match at the beginning
of the string.
^abc matches abc, but not aabc
$ (dollar sign)
Anchor the match at the end of the
string.
abc$ matches abc but not abcc
? (question mark)
Repeat the preceding expression zero
or one time.
aa? matches a or aa
* (asterisk)
Repeat the preceding expression zero
or more times.
ab*c matches ac, abc, abbc, etc.
+ (plus symbol)
Repeat the preceding expression one
or more times.
ab+c matches abc, abbc, etc.
[characterclass]
A series of nonrepeating characters
denoting a class.
[abcdefhijklmnopqrstuvwxyz] is the
class of all lowercase alphas.
[rangel`rangeh]
A sequential range of nonrepeating
characters denoting a class.
[a-z] is the class of all lowercase alphas.
[^characterclass]
Any character except those denoted
by a character class.
[^a-z] matches a numeric digit or a
punctuation mark.
[characterclass_tag]
[:alnum:] - Alphanumeric characters [[:alpha:]]* matches Dynaction,
[:alpha:] - Alphabetic characters
Selmer, or NewWonder but not Su[:blank:] - Tab and space
per20
[:cntrl:] - Control characters
[:digit:] - Numeric characters
[:graph:] - All printable characters except space
[:lower:] - Lowercase letters
[:print:] - All printable characters
[:punct:] - Punctuation
[:space:] - White space characters
[:upper:] - Uppercase letters
[:xdigit:] - Hexadecimal digits
{num}
Matches exactly num repetitions.
a{3} matches only aaa
{min,}
Matches at least num repetitions.
a{3,} matches aaaa but not aa
142
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Filter Expression Values (continued)
Operator
Meaning
Example
{min,max}
A repetition operator like + or *, ex- [a-z]{1,3} matches a, ab, or aab, but
cept the number of repetitions is spe- not aabc
cified by min and max.
(expr1)|(expr2)
Matches expr1 or expr2.
a|b matches a or b
(subexpression)
Grouping operator to consolidate
terms into a subexpression, which
can override the order of evaluation.
Overriding evaluation order: (ab)*c
matches c, abc, ababc, etc.
Back-referencing: (aa)bb\1 matches
The subexpression is available for lat- aabbaa.
er matching or editing by means of
\index, where \index is between 1-9
and refers to the index-th group in
the string, counting from left to
right. \0 refers to the whole expression.
700 Series Color Mobile Computer User’s Manual
143
Chapter 6 — Scanner Support
Editing Expression Values
This table lists the valid operators for editing expressions.
Operator
Meaning
\index
The index-th subexpression (reading left-right) M([0-9]{6})= > \1 produces 270494 when
in the matched string. index must be between M270494 is scanned, stripping off the first
0`9. \0 is the matched expression itself.
character.
& or \0
The matched expression itself.
M[0-9]{6}= > \0-Conn and
M[0-9]{6}= > &-Conn
both produce
M270494-Conn
when M270494 is scanned.
\xhh
A concise representation of the lower 256
characters in the Unicode set. When converted, this is still a 16-bit value.
\x0d inserts a carriage return.
any character string Inserts any character string in the output
string.
Example
See previous examples.
S  is optional. If present, only data in the indicated symbology is
accepted.
S If the entire expression is blank, all data is passed unchanged. If = >
editing-expression is omitted, then all data that passes through the filter is
returned unchanged. If = > editing expression is present, the data is transformed by editing-expression.
S Multiple grid expressions can be compiled and are related in a logical
OR fashion. These are expressed as single grid expressions separated by
semicolons. When matching is attempted, the first grid expression from
left to right that achieves a match will cause the data to be accepted.
S All pattern expressions and parsed data are in Unicode.
Grid Filter Example 1
This accepts a serial number in which the encoded number is a six-character string beginning with M followed by six numeric characters.
S Filter
M[0-9]{6}
S Effect
When a bar code, such as M270494, is scanned, all data is passed.
Grid Filter Example 2
This formats a scanned Social Security number and forms it into an XML
element tagged “SSN”.
S Filter
([0-9]{3})([0-9]{2})([0-9]{4})= >  \1-\2-\3
S Effect
A bar code, such as 123456789, is passed and reformatted to
 123-45-6789
144
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Grid Filter Example 3
This deletes the first three and last five characters of a 21-character Code
128 label and deletes the first two characters of a 10-character Interleaved
2 of 5 label.
S Filter
<]C > ...(.{13}).....= > \1; <]I > ..(........)= > \1
S Effect
If Code 128, AAA1234567890123BBBBB becomes 1234567890123
If Interleaved 2 of 5, AA12345678 becomes 12345678
Grid Filter Example 4
This inverts data such that the first alphabetic string (like a first name) and
second alphabetic string (like a last name) are reversed and separated by a
comma and a space.
S Filter
([[:alpha:]])+ ([[:alpha:]])+= > \2, \1
S Effect
When a bar code with the data “Dexter Gordon” is scanned, the data is
modified to read “Gordon, Dexter”.
ADC Connection
A 700 Series Computer can have both Bar Code and RFID reader engines
with each engine supporting multiple connections. Each connection allows
an application to access data or manage a configuration. An application
could have multiple connections.
// Get an instance of the ADC COM object that corresponds integrated scanner
IBarCodeReaderControl *pIBCControl;
// Pointer to the Bar Code Reader object
HRESULT hrStatus = ITCDeviceOpen( TEXT(”default”),
IID_IBarCodeReaderControl, ITC_DHDEVFLAG_READAHEAD,
(LPVOID *) &pIBCControl);
// If the ADC object was successfully created and initialized, accept bar
code data.
ITC_BARCODE_DATA_DETAILS stBCDetails;
stBCDetails.wStructSize = sizeof(stBCDetails);
BYTE rgbBCData[1024];
//Buffer used to accept the bar code data
DWORD dwBytesReceived;
// Number of bytes in the return data.
HRESULT hrStatus = pIBCControl->Read(
rgbBCData,
sizeof(rgbBCData),
&dwBytesReceived,
& stBCDetails,
INFINITE
);
700 Series Color Mobile Computer User’s Manual
145
Chapter 6 — Scanner Support
2D Imager Overview
The 700 Color optional integrated 2D Imager captures 640x480
256-grayscale images at 20 frames per second. The imager features can be
categorized into data collection features and image acquisition features as
follows:
Data Collection Features
The imager includes a decode engine capable of decoding 2D matrix
symbologies such as Data Matrix as well as the traditional 1D and stacked
symbologies (see the table on the next page for supported symbologies). The
application programming interfaces used to collect bar code data and configure the imager are the same as those used for the laser scanner. This includes the keyboard wedge as well as the ADC COM interfaces and includes functionality such as data editing and data filtering. In addition, the
imager has the following configuration features (see “IS9CConfig3 Functions” starting on page 216 for configuration details):
S Aimer LED:
A small, rectangular-aiming LED is displayed periodically during the
image capture and decoding process. The initial duration (after scan buttons are pressed) of the aimer LED can be configured. This helps to select
the specific bar code to be scanned with multiple bar codes in the
image.
S Scaled Illumination LED:
When the ambient light is not sufficient to decode the bar code, the red
illumination LEDs will be turned on to brighten the image. The intensity of the illumination LEDs is scaled to brighten the image just
enough for decode. The reduces power consumption and the effect of
specular reflection.
S Window size and position:
The default window size (640x480) can be reduced in size and positioned. This is useful in applications where multiple bar codes may be
present in the image and the specific bar code must be selected to be
read. For example, the window can be sized and positioned around the
aimer LED. The entire bar code must reside in the configured window
for a good decode.
Omni-directional scanning is a feature that does not require configuration.
1D and stacked symbologies as well as 2D matrix symbologies can be
scanned with the 700 Series Computer in any orientation. Thus, time is
not needed to orient the 700 horizontal as with laser scanners.
146
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
The following table shows which bar code symbologies are supported either by an imager or by a laser scanner.
Bar Code Symbology
Imager
Laser Scanner
Code 39
Interleaved 2 of 5
Standard 2 of 5
Matrix 2 of 5
Code 128
Code 93
Codabar
MSI
Plessey
UPC
EAN/EAN 128
Code 11
PDF 417
Micro PDF 417
Telepen
Data Matrix
QR Code
Image Acquisition Features
The integrated imager provides the following image acquisition features:
S Real-time and Still Image Acquisition:
This includes functions that start and stop image acquisition and read
acquired images.
S Signature Capture:
This allows the application to retrieve an image of the normalized signature. This means the image is always oriented as if the picture were taken at right angles to the signature, at the same distance, and in the center of the image no matter in what orientation the picture was taken.
Signature capture requires a PDF 417 or Code 128 bar code symbology
to be present in the image and requires the application to identify the
X,Y offsets relative to the center the bar code, the X,Y dimension of
image to be captured, and the aspect ratio of the bar code. Note the
units are in terms of the narrow element width of the bar code.
700 Series Color Mobile Computer User’s Manual
147
Chapter 6 — Scanner Support
See the following example signature capture label and dimensions. These
image acquisition features are provided through the IImage Interface
defined on page 221.
Y-axis
Bar code height
–X
Intelligent bar code
units
–Y
148
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Create and Delete ADC COM Object Functions
Use these functions to create and release ADC COM interfaces.
ITCDEVMGMT.H is the header file and ITCDEVMGMT.LIB is the
library.
ITCDeviceOpen
This function opens and initializes a communication channel to the device. In C++, this function returns a pointer to an interface on which the
methods are called. In C, this function returns a handle, which is the first
parameter in each of the interface function calls.
Syntax
HRESULT ITCDeviceOpen( LPCTSTR pszDeviceName, REFIID iid,
ITC_DEVICE_FLAGS eDeviceFlags, void** ppvObject );
Parameters
pszDevice
[in]
Pointer to a string that contains the device name
on which to initialize the logical connection.
The device name (Merlin 1) identifies a
communications port.
Use “default” for all internal scanners, such as
Imager, SE900, etc. Use “ExtScanner” for
tethered scanners.
iid
[in]
The identifier of the interface being requested.
eDeviceFlags
[in]
Enumeration that identifies the read
characteristics as follows:
S ITC_DHDEVFLAG_READAHEAD
Data is buffered on behalf of the calling
applications. Data Buffering starts after the
first call to IADC::Read ().
S ITC_DHDEVFLAG_NODATA
The client application is managing the device
to set its configuration or control its interface
but not to collect data from the device.
ppvObject
[out]
A pointer to the interface pointer identified by
iid. If the object does not support this interface,
ppvObject is set to NULL.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
S ITCDeviceClose
700 Series Color Mobile Computer User’s Manual
149
Chapter 6 — Scanner Support
ITCDeviceClose
This function closes the interface opened with ITCDeviceOpen.
Syntax:
HRESULT ITCDeviceClose( IUnknown** ppvObject );
Parameters
ppvObject
[in,out]
A pointer to the interface pointer created by
ITCDeviceOpen. If successful on output, this
pointer is set to NULL.
Return Values
None.
Remarks
On Windows, this interface decrements the reference count. So alternatively, IUnknown::Release() could be used and must be used if reference
counting is performed with IUnknown::AddRef(). On DOS, this function
closes all resources associated with the channel.
See Also
None.
150
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IADC Functions
IADC functions provide ADC data in an input device independent manner. This interface can receive bar code data, RFID data, and other ADC
data from data collection engines, such as a bar code scanner. Use IADC
functions if bar code specifics such as symbology are not important to the
application.
IADC functions are the following. IADC.H is the header file and
ITCUUID.LIB contains the IID_IADC Interface GUID value used to
obtain the interface.
S IADC::CancelReadRequest (page 152)
S IADC::Initialize (page 153)
S IADC::QueryAttribute (page 154)
S IADC::QueryData (page 155)
S IADC::Read (page 156)
S IADC::SetAttribute (page 157)
700 Series Color Mobile Computer User’s Manual
151
Chapter 6 — Scanner Support
IADC::CancelReadRequest
This function cancels a pending Read() request. This call can be made on a
separate thread as a Read() or on the same thread. On a separate thread,
the function is useful in unblocking a blocked Read() so that other operations can be performed. On the same thread, this function is useful in
stopping data from being collected on behalf of a Read Ahead Client.
Syntax
HRESULT IADC::CancelReadRequest( BOOL FlushBufferedData,WORD
*pwTotalDiscardedMessages, DWORD *pdwTotalDiscardedBytes );
Parameters
FlushBufferedData
[in] True Flush and discard all already
buffered data.
False Do not discard data, data will be
returned on the next read call.
pwTotalDiscardedMessages [in/out]
Total number of discarded buffered
labels or tags.
pdwTotalDiscardedBytes
Total number of discarded bytes.
Return Values
HRESULT that indicates success or failure.
Remarks
The return value indicates whether a read was pending.
See Also
S IADC::Initialize
S IADC::QueryAttribute
S IADC::QueryData
S IADC::Read
S IADC::SetAttribute
152
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IADC::Initialize
This function initializes a connection by opening a communications channel with a logical reader engine. The communications port is implicitly
identified. This communication channel is required to collect data or configure the device.
Syntax
HRESULT IADC::Initialize ( LPCTSTR pszDeviceName,
ITC_DEVICE_FLAGS eDeviceFlags ) ;
Parameters
pszDeviceName
[in] Pointer to a string that contains the device name
on which to initialize the logical connection.
The device name (Merlin 1) identifies a
communications port.
Use “default” for all internal scanners, such as
Imager, SE900, etc. Use “ExtScanner” for
tethered scanners.
eDeviceFlags
[in] Enumeration that identifies the read
characteristic as follows:
S ITC_DHDEVFLAG_READAHEAD
Data is buffered on behalf of the calling
application. Data buffering starts after the
first call to IADC::Read ().
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
S IADC::CancelReadRequest
S IADC::QueryAttribute
S IADC::QueryData
S IADC::Read
S IADC::SetAttribute
700 Series Color Mobile Computer User’s Manual
153
Chapter 6 — Scanner Support
IADC::QueryAttribute
This function retrieves a specified attribute that is device-independent.
The specified attribute can be a grid or multiclient enable status.
Syntax
HRESULT IADC::QueryAttribute (
ITC_ADC_ATTRIBUTE_ID eAttribID, BYTE rgbBuffer[], DWORD
dwBufferSize, DWORD *pnBufferData );
Parameters
eAttribID
[in]
Specifies the attribute. Only one attribute can be
queried at a time. See IADC::SetAttribute.
rgbBuffer
[out]
Contains buffer for the attribute to be queried.
The structure of lpBuffer depends on the
attribute being queried. See IADC::SetAttribute
for a description of these structures.
dwBufferSize
[in]
The maximum number of bytes rgbBuffer can
store.
pnBufferData [out]
Pointer to the DWORD location to put the
number of bytes stored in rgbBuffer.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
S IADC::CancelReadRequest
S IADC::Initialize
S IADC::QueryData
S IADC::Read
S IADC::SetAttribute
154
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IADC::QueryData
This function returns the status of user input data that has been buffered.
Syntax
HRESULT IADC::QueryData ( DWORD *dwTotalBufferedBytes, WORD
*wNumberOfMessages, DWORD *dwNextMessageSize );
Parameters
dwTotalBufferedBytes
[out]
Total bytes buffered for connection.
wNumberOfMessages
[out]
Total messages buffered. For example,
each buffer contains a single bar code scan.
dwNextMessageSize
[out]
Size (in bytes) of the next buffered
message.
Return Values
A standard status code that indicates success or failure.
Remarks
None.
See Also
S IADC::CancelReadRequest
S IADC::Initialize
S IADC::QueryAttribute
S IADC::Read
S IADC::SetAttribute
700 Series Color Mobile Computer User’s Manual
155
Chapter 6 — Scanner Support
IADC::Read
This function requests user input data from the reader engine. This is a
blocking function that returns either when there is data or after a timeout.
Syntax
HRESULT IADC::Read ( BYTE rgbDataBuffer[], DWORD
dwDataBufferSize, DWORD pnBytesReturned, SYSTEMTIME
pSystemTime, DWORD dwTimeout );
Parameters
rgbDataBuffer
[in]
Pointer to the buffer that receives the data
from the device.
dwDataBufferSize
[in]
Maximum number of bytes that can be
stored in rgbDataBuffer.
pnBytesReturned
[out]
Pointer to the DWORD location to store
the number of bytes returned in
rgbDataBuffer.
pSystemTime
[out]
Pointer to a SYSTEMTIME structure that
will hold the time stamp of the received
data. This can be NULL if a timestamp is
not needed.
dwTimeout
[in]
Number of milliseconds caller waits for
data. This parameter is ignored if the
Read Ahead flag is not set.
S 0
If data is not available, returns quickly.
S INFINITE
Waits until data is available.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
S IADC::CancelReadRequest
S IADC::Initialize
S IADC::QueryAttribute
S IADC::QueryData
S IADC::SetAttribute
156
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IADC::SetAttribute
This function changes an attribute such as a grid specification.
Syntax
HRESULT IADC::SetAttribute ( ITC_ADC_ATTRIBUTE_ID eAttribID,
BYTE rgbData[], DWORD nBufferSize );
Parameters
eAttribID
rgbData
[in] Identifies the attribute to set. Only one attribute
can be set at a time. The attribute is:
S ITC_MULTICLIENT_ENABLE
Indicates whether this client can coexist with
other clients.
[in] Contains data for the attribute to be set.
Depending on the eAttribID, this will be mapped
to the appropriate structure as follows:
S ITC_MULTICLIENT_ENABLE
BOOL is the rgbData Data Structure.
S TRUE, Client can receive data with other
clients (default).
S FALSE, Data stream to this client is turned
off when there are other clients.
S ITC_DHATTR_READFILTER
ITC_READFILTER is the rgbData Data
Structure. The ITC_READFILE structure is
defined in IADCDEVICE.H as follows:
typedef struct
#define ITC_MAXFILTER_CHARS 240
WORD
nFilterChars;
TCHAR
szFilter[ITC_MAXFILTER_CHARS];
} ITC_READFILTER;
where:
S ITC_MAXFILTER_CHARS
Maximum number of characters in a filter
specification. Includes NULL termination.
S nFilterChars Number of characters in
pszDataMask.
S szFilter
Data mask specification. See
“Grid Data Filtering.”
nBufferSize [in] Number of bytes in rgbData.
ITC_DHATTR_READFILTER
Regular expression that performs data filtering and data editing. See “Grid
Data Filtering” on page 141 for more information.
Return Values
A standard status code that indicates success or failure.
Remarks
None.
700 Series Color Mobile Computer User’s Manual
157
Chapter 6 — Scanner Support
See Also
S IADC::CancelReadRequest
S IADC::Initialize
S IADC::QueryAttribute
S IADC::QueryData
S IADC::Read
158
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IBarCodeReaderControl Functions
IBarCodeReaderControl functions provide functionality for bar code
collection and control only. These functions allow an application to:
S Trigger the bar code laser scanner
S Disable the scanner
S Receive a bar code with details such as symbology scanned, data type
(Unicode, ASCII), and the time the data was received.
These functions include the following. IBARCODEREADER.H is the
header file and ITCUUID.LIB contains the IID_IADC Interface GUID
value used to obtain the interface.
S IBarCodeReaderControl::CancelReadRequest (page 160)
S IBarCodeReaderControl::ControlLED (page 161)
S IBarCodeReaderControl::Initialize (page 162)
S IBarCodeReaderControl::IssueBeep (page 163)
S IBarCodeReaderControl::QueryAttribute (page 164)
S IBarCodeReaderControl::Read (page 165)
S IBarCodeReaderControl::SetAttribute (page 167)
S IBarCodeReaderControl::TriggerScanner (page 171)
700 Series Color Mobile Computer User’s Manual
159
Chapter 6 — Scanner Support
IBarCodeReaderControl::CancelReadRequest
This function cancels a pending IBarCodeReaderControl::Read request. If
the read request is blocked, issue the CancelReadRequest from a separate
thread.
Syntax
HRESULT IBarCodeReaderControl::CancelReadRequest( BOOL
FlushBufferedData, WORD *pwTotalDiscardedMessages,WORD
*pwTotalDiscardedBytes );
Parameters
FlushBufferedData
[in] TRUE
FALSE
Flushes and discards all buffered
data.
Does not discard data; data will
be returned on the next read
call.
pwTotalDiscardedMessages [in/out]
Total number of discarded
buffered labels or tags.
pwTotalDiscardedBytes
Total number of discarded
bytes.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
S IBarCodeReaderControl::ControlLED
S IBarCodeReaderControl::Initialize
S IBarCodeReaderControl::IssueBeep
S IBarCodeReaderControl::QueryAttribute
S IBarCodeReaderControl::Read
S IBarCodeReaderControl::SetAttribute
S IBarCodeReaderControl::TriggerScanner
160
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IBarCodeReaderControl::ControlLED
This function controls LED illumination on a tethered scanner. The good
read LED and any valid LEDs will be turned on and off based on defined
parameters.
Syntax
HRESULT IBarCodeReaderControl::ControlLED(
ITC_BARCODE_LASER_LED_ID eLED, BOOL fLedOn );
Parameters
eLED
[in] The specified LED identifier.
S ITC_BARCODE_LASER_GOOD_READ_LED
Identifies the good read LED.
fLedOn
[in] TRUE turns on the LED. FALSE turns off the LED.
Return Values
HRESULT that indicates success or failure.
Remarks
This function does not coordinate LED control with the scanner. If the
scanner LED control is enabled, function results will be unpredictable.
See Also
S IBarCodeReaderControl::CancelReadRequest
S IBarCodeReaderControl::Initialize
S IBarCodeReaderControl::IssueBeep
S IBarCodeReaderControl::QueryAttribute
S IBarCodeReaderControl::Read
S IBarCodeReaderControl::SetAttribute
S IBarCodeReaderControl::TriggerScanner
700 Series Color Mobile Computer User’s Manual
161
Chapter 6 — Scanner Support
IBarCodeReaderControl::Initialize
This function opens and initializes a communications channel with a logical bar code reader engine.
Syntax
HRESULT IBarCodeReaderControl::Initialize ( LPCTSTR
pszDeviceName, ITC_DEVICE_FLAGS eDeviceFlags ) ;
Parameters
pszDeviceName
[in] Pointer to a string with device on which to
initialize the logical connection. The device
identifies a communications port. Use “default”
for all internal scanners, such as Imager, SE900,
etc. Use “ExtScanner” for tethered scanners.
eDeviceFlags
[in] Enumeration that identifies the read
characteristic as follows:
S ITC_DHDEVFLAG_READAHEAD
Data is buffered on behalf of the calling
applications. Data Buffering starts after the
first call to IADC::Read ().
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
S IBarCodeReaderControl::CancelReadRequest
S IBarCodeReaderControl::ControlLED
S IBarCodeReaderControl::IssueBeep
S IBarCodeReaderControl::QueryAttribute
S IBarCodeReaderControl::Read
S IBarCodeReaderControl::SetAttribute
S IBarCodeReaderControl::TriggerScanner
162
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IBarCodeReaderControl::IssueBeep
This function causes the reader engine to generate a high beep, a low beep,
or a custom beep. The high beep and low beep are preconfigured beep
tones and durations. The custom beep allows the client to specify the frequency and duration. The volume is the current volume setting. Note this
is not implemented.
Syntax
HRESULT IBarCodeReaderControl::IssueBeep( ITC_BEEP_SPEC
rgBeepRequests[], DWORD dwNumberOfBeeps );
Parameters
rgBeepRequests
[in] Array of ITC_BEEP_SPEC structures that
identifies the beep type. The beep structure
is:
typedef struct tagITCBeepSpec
ITC_BEEP_TYPE eBeepType; // Identifies the type of beep
// Following fields used only if the beep type is ITC_CUSTOM_BEEP.
WORD wPitch; // Frequency, in Hz, of the beep.
WORD wOnDuration; // Duration, in milliseconds, of Beep On.
WORD wOffDuration; // Duration, in milliseconds, of Beep Off
// Beep Off is used to separate individual beeps
} ITC_BEEP_SPEC;
typedef enum tagITCBeepType
ITC_LOW_BEEP, // Issue the default low beep.
ITC_HIGH_BEEP, // Issue the default high beep.
ITC_CUSTOM_BEEP, // Issue a custom beep.
} ITC_BEEP_TYPE;
dwNumberOfBeeps
[in] Identifies the total number of beeps in
rgBeepRequests.
Return Values
E_NOTIMPL as this function is not implemented.
Remarks
None.
See Also
S IBarCodeReaderControl::CancelReadRequest
S IBarCodeReaderControl::ControlLED
S IBarCodeReaderControl::Initialize
S IBarCodeReaderControl::QueryAttribute
S IBarCodeReaderControl::Read
S IBarCodeReaderControl::SetAttribute
S IBarCodeReaderControl::TriggerScanner
700 Series Color Mobile Computer User’s Manual
163
Chapter 6 — Scanner Support
IBarCodeReaderControl::QueryAttribute
This function retrieves the device-specific grid, the scanner enable status,
and the LED control status for the current bar code reader engine.
Syntax
HRESULT IBarCodeReaderControl::QueryAttribute (
ITC_BARCODEREADER_ATTRIBUTE_ID eAttr, BYTE rgbAttrBuffer[],
DWORD dwAttrBufferSize );
Parameters
eAttr
[in]
Specifies the attribute. See
IBarCodeReaderControl::SetAttribute on
page 167 for the attributes.
rgbAttrBuffer
[out]
Contains buffer for the attribute to be
queried. The structure of rgbAttrBuffer
depends on the attribute being queried.
See IBarCodeReaderControl::SetAttritbute
for a description of these structures.
dwAttrBufferSize
[in]
The maximum number of bytes that
rgbAttrBuffer can store.
Return Values
A standard status code that indicates success or failure.
Remarks
The following attributes are not supported on the imager:
S ITC_RDRATTR_TONE_ENABLE
S ITC_RDRATTR_VOLUME_LEVEL
S ITC_RDRATTR_TONE_FREQUENCY
S ITC_RDRATTR_GOOD_READ_BEEPS_NUMBER
S ITC_RDRATTR_GOOD_READ_BEEP_DURATION
See Also
S IBarCodeReaderControl::CancelReadRequest
S IBarCodeReaderControl::ControlLED
S IBarCodeReaderControl::Initialize
S IBarCodeReaderControl::IssueBeep
S IBarCodeReaderControl::Read
S IBarCodeReaderControl::SetAttribute
S IBarCodeReaderControl::TriggerScanner
164
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IBarCodeReaderControl::Read
This function reads data from the bar code input device. This method performs the same function as IADC::Read () except that it provides additional information about data received such as bar code symbology used, data
type, and time stamp of received data.
Syntax
HRESULT IBarCodeReaderControl::Read ( BYTE
rgbDataBuffer[],DWORD dwDataBufferSize, DWORD
pnBytesReturned,ITC_BARCODE_DATA_DETAILS
pBarCodeDataDetails, DWORD dwTimeout );
Parameters
rgbDataBuffer
[in]
Pointer to the buffer that receives data
from the device.
dwDataBufferSize
[in]
Maximum number of bytes that can be
stored in rgbDataBuffer.
pnBytesReturned
[out]
Pointer to the DWORD location that will
store the bytes returned in rgbDataBuffer.
pBarCodeDataDetails [in]
Address of data structure in which to put
the data details. This may be NULL. The
ITC_BARCODE_DATA_DETAILS is:
typedef struct tagITCBarCodeDetails
WORD wStructSize,
ITC_BARCODE_SYMBOLOGY_ID eSymbology,
ITC_BARCODE_DATATYPE eDataType,
SYSTEMTIME stTimeStamp,
}ITC_BARCODE_DATA_DETAILS;
typedef enum tagBarCodeDataType
BARCODE_DATA_TYPE_UNKNOWN = 1,
BARCODE_DATA_TYPE_ASCII,
BARCODE_DATA_TYPE_UNICODE,
}ITC_BARCODE_DATATYPE;
where:
S wStructSize
Size of structure. Used for versioning structure.
S eSymbology
Symbology of the returned data.
S eDataType
Identifies data types as ASCII, UNICODE, etc.
S stTimeStamp
Timestamp of the received data.
S BARCODE_DATA_TYPE_UNKNOWN
Data in unknown.
S BARCODE_DATA_TYPE_ASCII
Data is ASCII.
S BARCODE_DATA_TYPE_UNICODE
Data is UNICODE.
700 Series Color Mobile Computer User’s Manual
165
Chapter 6 — Scanner Support
dwTimeout
[in]
Number of milliseconds caller waits for
data. If you set a timeout, the call will be
blocked until data is received.
S 0
If data not available, returns quickly.
S INFINITE
Waits until data is available.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
S IBarCodeReaderControl::CancelReadRequest
S IBarCodeReaderControl::ControlLED
S IBarCodeReaderControl::Initialize
S IBarCodeReaderControl::IssueBeep
S IBarCodeReaderControl::QueryAttribute
S IBarCodeReaderControl::SetAttribute
S IBarCodeReaderControl::TriggerScanner
166
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IBarCodeReaderControl::SetAttribute
This function enables and disables the laser scanner, sets the bar code reader engine specific grid, and enables or disables the reader engine LED control.
Syntax
HRESULT IBarCodeReaderControl::SetAttribute (
ITC_BARCODEREADER_ATTRIBUTE_ID eAttr, BYTE rgbAttrBuffer[],
DWORD dwAttrBufferSize );
Parameters
eAttr
[in] Identifies the attribute to set. Only one attribute can be set
at a time. The attributes are:
S ITC_RDRATTR_SCANNER_ENABLE
Enable or disable scanner for all connections.
S ITC_RDRATTR_GOOD_READ_LED_ENABLE
Enables and disables the reader engine from controlling
the good read LED.
S ITC_RDRATTR_TONE_ENABLE
Enables and disables the reader engine from issuing
beeps.
S ITC_RDRATTR_VOLUME_LEVEL
Sets beep volume level.
S ITC_RDRATTR_TONE_FREQUENCY
Sets beep frequency.
S ITC_RDRATTR_GOOD_READ_BEEPS_NUMBER
Sets number of beeps for a good read.
S ITC_RDRATTR_GOOD_READ_BEEP_DURATION
Sets duration of beeps for a good read.
S ITC_DHATTR_READFILTER
The ITC_READFILTER is the rgbData Data Structure.
The ITC_READFILE structure is defined in
IADCDEVICE.H as follows:
typedef struct
#define ITC_MAXFILTER_CHARS 240
WORD nFilterChars;
TCHAR szFilter[ITC_MAXFILTER_CHARS];
} ITC_READFILTER;
where:
S nFilterChars Number of characters in pszDataMask.
S szFilter
Data mask specification. See “Grid Data
Filtering.”
S ITC_MAXFILTER_CHARS
Maximum number of characters in a filter specification.
Includes NULL termination.
700 Series Color Mobile Computer User’s Manual
167
Chapter 6 — Scanner Support
rgbAttrBuffer [in] Contains data for the attribute to be set. Depending
on eAttr, the rgbAttrData will be mapped to the
appropriate structure as shown in the following table .
rgbAttrBuffer Data Structures
eAttr
Data Structure contained in rgbAttrBuffer
ITC_RDRATTR_GRID
ITC_BARCODEREADER_READER_GRID
Reader Engine specific grid only.
ITC_RDRATTR_SCANNER_ENABLE
BOOL
TRUE Enable scanner.
FALSE Disable scanner.
ITC_RDRATTR_GOOD_READ_LED_ENABLE
BOOL
TRUE Reader Engine controls good read LED.
FALSE Good read LED is not controlled.
ITC_RDRATTR_DATA_VALID_LED_ENABLE
BOOL
TRUE Reader Engine controls data valid LED.
FALSE Data valid LED is not controlled.
ITC_RDRATTR_TONE_ENABLE
BOOL
TRUE Reader Engine issues beeps.
FALSE Beeps are not issued.
ITC_RDRATTR_VOLUME_LEVEL
ITC_BEEP_VOLUME
An enumerator that identifies the beep volume level control. Valid range for S9C:
typedef enum tagBeepVolume
ITC_BEEP_VOLUME_LOW = 0,
ITC_BEEP_VOLUME_MEDIUM = 2,
ITC_BEEP_VOLUME_HIGH = 1 //Default
}ITC_BEEP_VOLUME
Note: Due to the hardware design on this 700 Series Computer, the volume level can be either
OFF (ITC_BEEP_VOLUME_LOW) or
ON (ITC_BEEP_VOLUME_MEDIUM/HIGH).
ITC_RDRATTR_TONE_FREQUENCY
168
DWORD
A value that identifies the tone frequency in Hz. Valid
range for S9C: 1000`4095 Hz (default: 2090).
Note: Value is divided by 10 for storage. On retrieval, the
scanner rounds off the value to the nearest 10 Hz, then multiplies the value by 10. For example, the value sent to the
scanner is 2095. On retrieval, the value returned is 2090.
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
rgbAttrBuffer Data Structures (continued)
eAttr
Data Structure contained in rgbAttrBuffer
ITC_RDRATTR_GOOD_READ_BEEPS_NUMBER
ITC_GOOD_READ_BEEPS_NUMBER
An enumerator identifying the good read beeps number.
Valid range for S9C:
typedef enum tagGoodReadBeepsNumber
ITC_NUM_BEEPS_NONE = 0,
ITC_NUM_BEEPS_ONE = 1, // Default
ITC_NUM_BEEPS_TWO = 2
}ITC_GOOD_READ_BEEPS_NUMBER
ITC_RDRATTR_GOOD_READ_BEEP_DURATION
dwAttrBufferSize
DWORD
Value identifying the good read beep duration in ms.
Valid range for S9C: 0`2550 ms (Default: 80).
Note: Value is divided by 10 for storage. On retrieval, the
scanner rounds the value to the nearest 10 ms, then multiplies the value by 10.
[in] The size of rgbAttrBuffer in bytes.
Return Values
HRESULT that indicates success or failure.
Remarks
Read ahead and non-read ahead clients can change the grid. Since
changing the grid changes the entire reader engine grid, use
IBarCodeReaderControl::QueryAttribute to retrieve the current reader
engine grid and grid changes before sending back using SetAttribute. The
grid structure is typedef struct tagBarCodeReaderGrid.
ITC_DI_GRID stDIGrid; // Device independent grid.
ITC_DDBARCODE_GRID stDDGrid; // Reader engine dependent grid
DWORD dwDataSourceTypeMask;
} ITC_BARCODEREADER_GRID;
ITC_DI_GRID
typedef struct tagItcBarCodeGrid
DWORD dwSymbologyMask; // Symbologies to be received.
} ITC_DDBARCODE_GRID;
When the scanner is enabled, it scans when the scan button is pressed or
the trigger is pulled. When the scanner is disabled, it does not respond
when the scan button is pressed or the trigger is pulled.
700 Series Color Mobile Computer User’s Manual
169
Chapter 6 — Scanner Support
The following attributes are not supported on the imager:
S ITC_RDRATTR_TONE_ENABLE
S ITC_RDRATTR_VOLUME_LEVEL
S ITC_RDRATTR_TONE_FREQUENCY
S ITC_RDRATTR_GOOD_READ_BEEPS_NUMBER
S ITC_RDRATTR_GOOD_READ_BEEP_DURATION
See Also
S IBarCodeReaderControl::CancelReadRequest
S IBarCodeReaderControl::ControlLED
S IBarCodeReaderControl::Initialize
S IBarCodeReaderControl::IssueBeep
S IBarCodeReaderControl::QueryAttribute
S IBarCodeReaderControl::Read
S IBarCodeReaderControl::TriggerScanner
170
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IBarCodeReaderControl::TriggerScanner
This function turns the scanner on and off. The client application must
coordinate control of the scanner with the user.
Syntax
HRESULT IBarCodeReaderControl::TriggerScanner ( BOOL
fScannerOn );
Parameters
fScannerOn
[in] Set TRUE to turn the scanner on. Set FALSE to turn
the scanner off.
Return Values
HRESULT that indicates success or failure.
Remarks
The scanner will be turned on or off independent of the actions of the users. The client application must coordinate control of the scanner with the
user. When the scanner is turned on, its behavior is controlled by the trigger mode. That is, in one shot mode, the laser turns off when a label is
scanned; in auto-trigger mode, the laser remains on.
See Also
S IBarCodeReaderControl::CancelReadRequest
S IBarCodeReaderControl::ControlLED
S IBarCodeReaderControl::Initialize
S IBarCodeReaderControl::IssueBeep
S IBarCodeReaderControl::QueryAttribute
S IBarCodeReaderControl::Read
S IBarCodeReaderControl::SetAttribute
700 Series Color Mobile Computer User’s Manual
171
Chapter 6 — Scanner Support
IS9CConfig Functions
This interface provides methods to set and retrieve the 700 Series Computer bar code configuration. All supported symbologies are initialized to
their defaults when the S9C firmware is loaded.
GET/SET functions use enumerations as their parameters. In most enumerations, there is an enumerator xx_NO_CHANGE (such as
ITC_CODE39_NO_CHANGE), where xx refers to a particular enumeration. This enumerator can be used during a call to a SET to indicate
that no change is to be made to that particular parameter. This prevents
the called function from having to format the same S9C command and
send down to the S9C scanner.
For all symbologies, to set a bar code length of “any length,” use a value of
“0” for the bar code length argument.
IS9CConfig functions are the following. IS9CCONFIG.H is the header
file and ITCUUID.LIB contains the IID_IADC Interface GUID value
used to obtain the interface.
172
IS9CConfig::GetCodabar (page 173)
IS9CConfig::SetCodabar (page 174)
IS9CConfig::GetCode39 (page 176)
IS9CConfig::SetCode39 (page 177)
IS9CConfig::GetCode93 (page 179)
IS9CConfig::SetCode93 (page 179)
IS9CConfig::GetCode128 (page 180)
IS9CConfig::SetCode128 (page 181)
IS9CConfig::GetI2of5 (page 183)
IS9CConfig::SetI2of5 (page 184)
IS9CConfig::GetMatrix2of5 (page 185)
IS9CConfig::SetMatrix2of5 (page 186)
IS9CConfig::GetMSI (page 187)
IS9CConfig::SetMSI (page 187)
IS9CConfig::GetPDF417 (page 188)
IS9CConfig::SetPDF417 (page 189)
IS9CConfig::GetPlessey (page 192)
IS9CConfig::SetPlessey (page 192)
IS9CConfig::GetStandard2of5 (page 194)
IS9CConfig::SetStandard2of5 (page 195)
IS9CConfig::GetTelepen (page 197)
IS9CConfig::SetTelepen (page 197)
IS9CConfig::GetUpcEan (page 198)
IS9CConfig::SetUpcEan (page 200)
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig::GetCodabar
This function retrieves the current settings of Codabar symbology.
Syntax
HRESULT IS9CConfig::GetCodabar( ITC_CODABAR_DECODING*
peDecode, ITC_CODABAR_START_STOP* peSS, ITC_CODABAR_CLSI*
peCLSI, ITC_CODABAR_CHECK_DIGIT* peCheck,
ITC_BARCODE_LENGTH_ID* peLengthId, BYTE rgbLengthBuff[],
DWORD* pdwNumBytes );
Parameters
peDecode
[out]
Pointer to the ITC_CODABAR_DECODING
location to receive the decoding for Codabar
symbology.
peSS
[out]
Pointer to the
ITC_CODABAR_START_STOP location to
receive the Start/Stop option.
peCLSI
[out]
Pointer to the ITC_CODABAR_CLSI location
to receive the CLSI library system.
peCheck
[out]
Pointer to the
ITC_CODABAR_CHECK_DIGIT location to
receive the check digit.
peLengthId
[out]
Pointer to the ITC_BARCODE_LENGTH_ID
location to receive an indicator of either
ITC_BARCODE_LENGTH or
ITC_BARCODE_FIXED_LENGTH.
rgbLengthBuff
[out,size_is(3)]
An array of bytes to receive 1 byte of data for
ITC_BARCODE_LENGTH, or 3 bytes of data
for ITC_BARCODE_FIXED_LENGTH.
pdwNumBytes
[out]
Pointer to the DWORD location to receive a
number indicating number of bytes in
rbgLengthBuff[]: 1 byte for
ITC_BARCODE_LENGTH or 3 bytes for
ITC_BARCODE_FIXED_LENGTH.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
700 Series Color Mobile Computer User’s Manual
173
Chapter 6 — Scanner Support
IS9CConfig::SetCodabar
This function updates the Codabar settings with new values.
Syntax
HRESULT IS9CConfig::SetCodabar( ITC_CODABAR_DECODING
eDecode, ITC_CODABAR_START_STOP eSS, ITC_CODABAR_CLSI
eCLSI,ITC_CODABAR_CHECK_DIGIT eCheck, ITC_BARCODE_LENGTH_ID
eLengthId, BYTE rgbLengthBuff[],DWORD dwNumBytes );
Parameters
eDecode
[in] Identifies the decoding for Codabar symbology.
eSS
[in] Identifies the Start/Stop option.
eCLSI
[in] Identifies the CLSI library system.
eCheck
[in] Identifies the check digit.
eLengthId
[in] Use
ITC_BARCODE_LENGTH_NO_CHANGE to
indicate no change for bar code length. Use
ITC_BARCODE_LENGTH for any length and
minimum length, and set rgbLengthBuff[0] to a
valid length value.
Use ITC_BARCODE_FIXED_LENGTH to
compose 1 or 2 or 3 fixed lengths, and set 3 bytes:
rgbLengthBuff[0], rgbLengthBuff[1],
rgbLengthBuff[2] with valid values.
rgbLengthBuff
[in,size_is(dwNumBytes)]
An array of bytes containing bar code lengths when
eLengthId = ITC_BARCODE_LENGTH or
ITC_BARCODE_FIXED_LENGTH.
dwNumBytes
[in] Number of bytes in rbgLengthBuff[]. For S9C, this
value is 1 when
eLengthId = ITC_BARCODE_LENGTH or 3
when eLengthId =
ITC_BARCODE_FIXED_LENGTH
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
174
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Codabar Default Settings
Parameter
Default
Valid Range
Decode
Not Active
ITC_CODABAR_DECODING
CLSI Library System
Not Active
ITC_CODABAR_CLSI
Start/Stop
Not Transmitted
ITC_CODABAR_START_STOP
Check Digit
Not Used
ITC_CODABAR_CHECK_DIGIT
Bar Code Length
Minimum Length = 6
0x00`0xFE
ITC_BC_LENGTH_NO_CHANGE
Codabar Enumerations
typedef enum tagCodabarDecoding
ITC_CODABAR_NOTACTIVE = 0,
ITC_CODABAR_ACTIVE = 1,
ITC_CODABAR_NO_CHANGE = 255
} ITC_CODABAR_DECODING;
typedef enum tagCodabarStartStop
ITC_CODABAR_SS_NOTXMIT,
ITC_CODABAR_SS_LOWERABCD,
ITC_CODABAR_SS_UPPERABCD,
ITC_CODABAR_SS_LOWERABCDTN,
ITC_CODABAR_SS_DC1TODC4,
ITC_CODABAR_SS_NO_CHANGE = 255
} ITC_CODABAR_START_STOP;
typedef enum tagCodabarClsi
ITC_CODABAR_CLSI_NOTACTIVE = 0,
ITC_CODABAR_CLSI_ACTIVE = 1,
ITC_CODABAR_CLSI_NO_CHANGE = 255
} ITC_CODABAR_CLSI;
// Default
//
//
//
//
//
Default
a,b,c,d
A,B,C,D
a,b,c,d / t,n,*,e
DC1,DC2,DC3,DC4
// Default
typedef enum tagCodabarCheckDigit
ITC_CODABAR_CHECK_NOTUSED,
ITC_CODABAR_CHECK_XMIT,
ITC_CODABAR_CHECK_NOTXMIT,
ITC_CODABAR_CHECK_NO_CHANGE = 255
} ITC_CODABAR_CHECK_DIGIT;
// Default
typedef enum tagBarcodeLengthId
ITC_BARCODE_LENGTH = 0,
ITC_BARCODE_FIXED_LENGTH,
ITC_BARCODE_LENGTH_NO_CHANGE = 255
} ITC_BARCODE_LENGTH_ID;
700 Series Color Mobile Computer User’s Manual
175
Chapter 6 — Scanner Support
IS9CConfig::GetCode39
This function retrieves the current settings of Code 39.
Syntax
HRESULT IS9Cconfig::GetCode39( ITC_CODE39_DECODING*
peDecode, ITC_CODE39_FORMAT* peFormat,
ITC_CODE39_START_STOP* peSS,ITC_CODE39_SS_CHARS* peSSChars,
ITC_CODE39_CHECK_DIGIT* peCheck, DWORD* pwLength );
Parameters
peDecode
[out]
Pointer to the ITC_CODE39_DECODING
location to receive the decoding for Code 39.
peFormat
[out]
Pointer to the ITC_CODE39_FORMAT location
to receive the Code 39 format.
peSS
[out]
Pointer to the ITC_CODE39_START_STOP
location to receive the Code 39 start/stop.
peSSChars
[out]
Pointer to the ITC_CODE39_SS_CHARS
location to receive the Start/Stop character.
peCheck
[out]
Pointer to the ITC_CODE39_CHECK_DIGIT
location to receive the check digit.
pwLength
[out]
Pointer to the DWORD location to receive the bar
code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
176
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig::SetCode39
This function updates the Code 39 settings with new values.
Syntax
HRESULT IS9CConfig::SetCode39( ITC_CODE39_DECODING
eDecode,ITC_CODE39_FORMAT eFormat, ITC_CODE39_START_STOP
eSS,ITC_CODE39_SS_CHARS eSSChars, ITC_CODE39_CHECK_DIGIT
eCheck, DWORD dwLength );
Parameters
eDecode
[in] Identifies the decoding for Code 39.
eFormat
[in] Identifies the Code 39 Format.
eSS
[in] Identifies the Start/Stop option.
eSSChars
[in] Identifies the Start/Stop character.
eCheck
[in] Identifies the Check digit.
dwLength
[in] Identifies the bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
Code 39 Default Settings
Parameter
Default
Valid Range
Decoding
Active
ITC_CODE39_DECODING
Format
Standard 43 Character ITC_CODE39_FORMAT
Start/Stop
Not Transmitted
ITC_CODE39_START_STOP
Accepted Start/stop Characters * only
ITC_CODE39_SS_CHARS
Check Digit
Not Used
ITC_CODE39_CHECK_DIGIT
Bar Code Length
Any Bar Code Length
0x00`0xFE
700 Series Color Mobile Computer User’s Manual
ITC_BC_LENGTH_NO_CHANGE
177
Chapter 6 — Scanner Support
Code 39 Enumerations
typedef enum tagCode39Decoding
ITC_CODE39_NOTACTIVE = 0,
ITC_CODE39_ACTIVE = 1,
ITC_CODE39_NO_CHANGE = 255
} ITC_CODE39_DECODING;
typedef enum tagCode39Format
ITC_CODE39_FORMAT_STANDARD43,
ITC_CODE39_FORMAT_FULLASCII,
ITC_CODE39_FORMAT_NO_CHANGE = 255
} ITC_CODE39_FORMAT;
typedef enum tagCode39StartStop
ITC_CODE39_SS_NOTXMIT,
ITC_CODE39_SS_XMIT,
ITC_CODE39_SS_NO_CHANGE = 255
} ITC_CODE39_START_STOP;
// Default
// Default
// Default
typedef enum tagCode39StartStopChars
ITC_CODE39_SS_CHARS_DOLLARSIGN,
ITC_CODE39_SS_CHARS_ASTERISK,
// Default
ITC_CODE39_SS_CHARS_BOTH,
ITC_CODE39_SS_CHARS_NO_CHANGE = 255
} ITC_CODE39_SS_CHARS;
typedef enum tagCode39CheckDigit
ITC_CODE39_CHECK_NOTUSED,
// Default
ITC_CODE39_CHECK_MOD43_XMIT,
ITC_CODE39_CHECK_MOD43_NOTXMIT,
ITC_CODE39_CHECK_FRENCH_CIP_XMIT,
ITC_CODE39_CHECK_FRENCH_CIP_NOTXMIT,
ITC_CODE39_CHECK_ITALIAN_CPI_XMIT,
ITC_CODE39_CHECK_ITALIAN_CPI_NOTXMIT,
ITC_CODE39_CHECK_NO_CHANGE = 255
} ITC_CODE39_CHECK_DIGIT;
178
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig::GetCode93
This function retrieves the current settings of Code 93.
Syntax
HRESULT IS9CConfig::GetCode93( ITC_CODE93_DECODING*
peDecode, DWORD* pdwLength );
Parameters
peDecode
[out]
Pointer to the ITC_CODE93_DECODING
location to receive the decoding for Code 93
symbology.
pdwLength
[out]
Pointer to the DWORD location to receive a value
for bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
IS9CConfig::SetCode93
This function updates the Code 93 settings with new values.
Syntax
HRESULT IS9CConfig::SetCode93( ITC_CODE93_DECODING
eDecode,DWORD dwLength );
Parameters
eDecode
[in] Identifies the decoding for Code93 Symbology.
dwLength
[in] Identifies the bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
Code 93 Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_CODE93_DECODING
Bar Code Length
Any Bar Code Length
0x00`0xFE
700 Series Color Mobile Computer User’s Manual
ITC_BC_LENGTH_NO_CHANGE
179
Chapter 6 — Scanner Support
Code 93 Enumerations
Use this when the bar code length does not require any change.
typedef enum tagCode93Decoding
ITC_CODE93_NOTACTIVE = 0,
// Default
ITC_CODE93_ACTIVE = 1,
ITC_CODE93_NO_CHANGE = 255
} ITC_CODE93_DECODING;
#define ITC_BC_LENGTH_NO_CHANGE 255.
IS9CConfig::GetCode128
This function retrieves the current settings of Code 128 symbology.
Syntax
HRESULT IS9Cconfig::GetCode128( ITC_CODE128_DECODING*
peDecode, ITC_EAN128_IDENTIFIER* peEan128Ident,
ITC_CODE128_CIP128 peCip128State, BYTE* pbyFNC1, DWORD*
pdwLength );
Parameters
peDecode
[out]
Pointer to the ITC_CODE128_DECODING
location to receive the decoding for Code 128
symbology.
peEan128Ident
[out]
Pointer to the ITC_EAN128_IDENTIFIER
location to receive the EAN 128 identifier.
peCip128State
[out]
Pointer to the ITC_CODE128_CIP128
location to receive the CIP 128.
pbyFNC1
[out]
Pointer to the BYTE location to receive the
FNC1 separator character.
pdwLength
[out]
Pointer to the DWORD location to receive a
value for bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
180
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig::SetCode128
This function updates the Code 128 settings with new values.
Syntax
HRESULT IS9CConfig::SetCode128( ITC_CODE128_DECODING
eDecode, ITC_EAN128_IDENTIFIER eEan128Ident,
ITC_CODE128_CIP128 eCip128State, BYTE byFNC1, DWORD dwLength
);
Parameters
eDecode
[in] Identifies the decoding for Code 128 symbology.
eEan128Ident
[in] Identifies the EAN 128 identifier.
eCip128State
[in] Identifies the CIP 128.
byFNC1
[in] Identifies the FNC1 separator character, usually
any ASCII value.
dwLength
[in] Identifies the bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
Code 128/EAN 128 Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_CODE128_DECODING
EAN 128 Identifier
Include ]C1
ITC_EAN128_IDENTIFIER
CIP 128 French Pharmaceutical
Codes
Not Active
ITC_CODE128_CIP128
FNC1 Separator Character (EAN
128 norms)
GS function Char
ASCII 29 or 0x1D
0x00`0xFE
ITC_CODE128_FNC1_NO_CHANGE
Bar Code Length
Any Bar Code Length
0x00`0xFE
ITC_BC_LENGTH_NO_CHANGE
700 Series Color Mobile Computer User’s Manual
181
Chapter 6 — Scanner Support
Code 128 Enumerations
typedef enum tagCode128Decoding
ITC_CODE128_NOTACTIVE = 0, // Default
ITC_CODE128_ACTIVE = 1,
ITC_CODE128_NO_CHANGE = 255
} ITC_CODE128_DECODING;
typedef enum tagEan128Identifier
ITC_EAN128_ID_REMOVE,
ITC_EAN128_ID_INCLUDE, // Default
ITC_EAN128_ID_NO_CHANGE = 255
} ITC_EAN128_IDENTIFIER;
typedef enum tagCode128Cip128
ITC_CODE128_CIP128_NOTACTIVE = 0, // Default
ITC_CODE128_CIP128_ACTIVE = 1,
ITC_CODE128_CIP128_NO_CHANGE = 255
} ITC_CODE128_CIP128;
#define ITC_CODE128_FNC1_NO_CHANGE 255.
This definition can be used when the Code128 FNC1 does not require any change.
#define ITC_BC_LENGTH_NO_CHANGE 255. This definition can be used when the bar
code length does not require any change.
The table below shows what to be expected for EAN 128 labels for various
symbology identifier transmit configurations and EAN 128 Identifier options.
Setup
Application’s Expected Result
EAN 128 ]C1 ID
Symbology ID option
EAN 128 Label
Other Labels
Include ]C1
Disabled


Remove ]C1
Disabled


Include ]C1
AIM ID Transmitted
]C1
]XY
Remove ]C1
AID ID Transmitted
]C1
]XY
Include ]C1
Custom ID Transmitted
Z]C1
Z
Remove ]C1
Custom ID Transmitted
Z
Z
where “X” is the symbology identifier, “Y” is the modifier character, and “Z” is the 1-byte symbology identifier.
182
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig::GetI2of5
This function retrieves the current settings of Interleaved 2 of 5.
Syntax
HRESULT IS9CConfig::GetI2of5( ITC_INTERLEAVED2OF5_DECODING*
peDecode, ITC_INTERLEAVED2OF5_CHECK_DIGIT* peCheck,
ITC_BARCODE_LENGTH_ID* peLengthId, BYTE rbgLengthBuff[],
DWORD* pdwNumBytes );
Parameters
peDecode
[out]
Pointer to the
ITC_INTERLEAVED2OF5_DECODING
location to receive the decoding for Interleaved
2 of 5 symbology.
peCheck
[out]
Pointer to the
ITC_INTERLEAVED2OF5_CHECK_DIGIT
location to receive the check digit.
peLengthId
[out]
Pointer to the ITC_BARCODE_LENGTH_ID
location to receive an indicator of either
ITC_BARCODE_LENGTH or
ITC_BARCODE_FIXED_LENGTH.
rgbLengthBuff
[out,size_is(3)]
An array of bytes to receives 1 byte of data for
ITC_BARCODE_LENGTH or 3 bytes of data
for ITC_BARCODE_FIXED_LENGTH.
pdwNumBytes
[out]
Pointer to the DWORD location to receive a
number indicating number of bytes in
rbgLengthBuff[]: 1 byte for
ITC_BARCODE_LENGTH or 3 bytes for
ITC_BARCODE_FIXED_LENGTH.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
700 Series Color Mobile Computer User’s Manual
183
Chapter 6 — Scanner Support
IS9CConfig::SetI2of5
This function updates the Interleaved 2 of 5 settings with new values.
Syntax
HRESULT IS9CConfig::SetI2of5( ITC_INTERLEAVED2OF5_DECODING
eDecode, ITC_INTERLEAVED2OF5_CHECK_DIGIT eCheck,
ITC_BARCODE_LENGTH_ID eLengthId, BYTE rgbLengthBuff[], DWORD
dwNumBytes );
Parameters
eDecode
[in] Identifies the decoding for Interleaved 2 of 5
symbology.
eCheck
[in] Identifies the check digit.
eLengthId
[in] Use
ITC_BARCODE_LENGTH_NO_CHANGE to
indicate no change for bar code length. Use
ITC_BARCODE_LENGTH for any length and
minimum length, and set rgbLengthBuff[0] to a
valid length value. Use
ITC_BARCODE_FIXED_LENGTH to compose
1 or 2 or 3 fixed lengths, and set 3 bytes:
rgbLengthBuff[0], rgbLengthBuff[1],
rgbLengthBuff[2] with valid values.
rgbLengthBuff
[in,size_is(dwNumBytes)]
Contains bar code lengths when eLengthId =
Use ITC_BARCODE_LENGTH or
Use ITC_BARCODE_FIXED_LENGTH.
dwNumBytes
[in] Number of bytes in rbgLengthBuff[]. For S9C, this
value is 1 when eLengthId =
ITC_BARCODE_LENGTH or 3 when eLengthId
= ITC_BARCODE_FIXED_LENGTH.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
Interleaved 2 of 5 Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_INTERLEAVED2OF5_DECODING
Check Digit
Not Used
ITC_INTERLEAVED2OF5_CHECK_DIGIT
Bar Code Length
Minimum Length = 6
0x00`0xFE
184
ITC_BC_LENGTH_NO_CHANGE
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Interleaved 2 of 5 Enumerations
typedef enum tagInterleaved2of5Decoding
ITC_INTERLEAVED2OF5_NOTACTIVE = 0,
// Default
ITC_INTERLEAVED2OF5_ACTIVE = 1,
ITC_INTERLEAVED2OF5_NO_CHANGE = 255
} ITC_INTERLEAVED2OF5_DECODING;
typedef enum tagInterleaved2of5CheckDigit
ITC_INTERLEAVED2OF5_CHECK_NOTUSED,
// Default
ITC_INTERLEAVED2OF5_CHECK_MOD10_XMIT,
ITC_INTERLEAVED2OF5_CHECK_MOD10_NOTXMIT,
ITC_INTERLEAVED2OF5_CHECK_FRENCH_CIP_XMIT,
ITC_INTERLEAVED2OF5_CHECK_FRENCH_CIP_NOTXMIT,
ITC_INTERLEAVED2OF5_CHECK_NO_CHANGE = 255
} ITC_INTERLEAVED2OF5_CHECK_DIGIT;
typedef enum tagBarcodeLengthId
ITC_BARCODE_LENGTH = 0,
ITC_BARCODE_FIXED_LENGTH,
ITC_BARCODE_LENGTH_NO_CHANGE = 255
} ITC_BARCODE_LENGTH_ID;
IS9CConfig::GetMatrix2of5
This function retrieves the current settings of Matrix 2 of 5.
Syntax
HRESULT IS9CConfig::GetMatrix2of5( ITC_MATRIX2OF5_DECODING*
peDecode, DWORD* pdwLength );
Parameters
peDecode
[out]
Pointer to the ITC_MATRIX2OF5_DECODING
location to receive the decoding for Matrix 2 of 5
symbology.
pdwLength
[out]
Pointer to the DWORD location to receive a value
for the bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
700 Series Color Mobile Computer User’s Manual
185
Chapter 6 — Scanner Support
IS9CConfig::SetMatrix2of5
This function updates the Matrix 2 of 5 settings with new values.
Syntax
HRESULT IS9CConfig::SetMatrix2of5( ITC_MATRIX2OF5_DECODING
eDecode, DWORD dwLength );
Parameters
eDecode
[in] Identifies the decoding for Matrix 2 of 5 symbology.
dwLength
[in] Identifies the bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
Matrix 2 of 5 Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_MATRIX2OF5_DECODING
Bar Code Length
Minimum Length = 6
0x00`0xFE
ITC_BC_LENGTH_NO_CHANGE
Matrix 2 of 5 Enumerations
typedef enum tagMatrix2of5Decoding
ITC_MATRIX2OF5_NOTACTIVE = 0, // Default
ITC_MATRIX2OF5_ACTIVE = 1,
ITC_MATRIX2OF5_NO_CHANGE = 255
} ITC_MATRIX2OF5_DECODING;
#define ITC_BC_LENGTH_NO_CHANGE 255. This definition can be used when the bar
code length does not require any change.
186
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig::GetMSI
This function retrieves the current MSI settings.
Syntax
HRESULT IS9CConfig::GetMSI( ITC_MSI_DECODING* peDecode,
ITC_MSI_CHECK_DIGIT* peCheck, DWORD* pdwLength );
Parameters
peDecode
[out]
peCheck
[out]
pdwLength
[out]
Pointer to the ITC_MSI_DECODING location to
receive the decoding for MSI symbology.
Pointer to the ITC_MSI_CHECK_DIGIT
location to receive the check digit.
Pointer to the DWORD location to receive the bar
code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
IS9CConfig::SetMSI
This function updates the MSI settings with new values.
Syntax
HRESULT IS9CConfig::SetMSI( ITC_MSI_DECODING eDecode,
ITC_MSI_CHECK_DIGIT eCheck, DWORD dwLength );
Parameters
eDecode
eCheck
dwLength
[in] Identifies the decoding for MSI symbology.
[in] Identifies the check digit.
[in] Identifies the bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
MSI Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_MSI_DECODING
Check Digit
MOD 10 checked and transmitted
ITC_MSI_CHECK_DIGIT
Bar Code Length
Minimum Length = 6
0x00`0xFE
700 Series Color Mobile Computer User’s Manual
ITC_BC_LENGTH_NO_CHANGE
187
Chapter 6 — Scanner Support
MSI Enumerations
typedef enum tagMsiDecoding
ITC_MSI_NOTACTIVE = 0, // Default
ITC_MSI_ACTIVE = 1,
ITC_MSI_NO_CHANGE = 255
} ITC_MSI_DECODING;
typedef enum tagMsiCheckDigit
ITC_MSI_CHECK_MOD10_XMIT, // Default
ITC_MSI_CHECK_MOD10_NOTXMIT,
ITC_MSI_CHECK_DOUBLEMOD10_XMIT,
ITC_MSI_CHECK_DOUBLEMOD10_NOTXMIT,
ITC_MSI_CHECK_NO_CHANGE = 255
} ITC_MSI_CHECK_DIGIT;
#define ITC_BC_LENGTH_NO_CHANGE 255. This definition can be used when the bar
code length does not require any change.
IS9CConfig::GetPDF417
This function retrieves the current PDF417 settings.
Syntax
HRESULT IS9CConfig::GetPDF417( ITC_PDF417_DECODING*
pePdf417Decode, ITC_PDF417_MACRO_PDF* peMacroPdf,
ITC_PDF417_CTRL_HEADER* pePdfControlHeader,
ITC_PDF417_FILE_NAME* pePdfFileName,
ITC_PDF417_SEGMENT_COUNT* pePdfSegmentCount,
ITC_PDF417_TIME_STAMP* pePdfTimeStamp, ITC_PDF417_SENDER*
pePdfSender, ITC_PDF417_ADDRESSEE* pePdfAddressee,
ITC_PDF417_FILE_SIZE* pePdfFileSize, ITC_PDF417_CHECKSUM*
pePdfChecksum );
Parameters
188
pePdf417Decode
[out]
Pointer to the
ITC_PDF417_DECODING location to
receive the decoding for PDF417
symbology.
Pointer to the
ITC_PDF417_MACRO_PDF location to
receive the Macro PDF.
peMacroPdf
[out]
pePdfControlHeader
[out]
Pointer to the
ITC_PDF417_CTRL_HEADER location
to receive the control header.
pePdfFileName
[out]
pePdfSegmentCount
[out]
pePdfTimeStamp
[out]
Pointer to the
ITC_PDF417_FILE_NAME location to
receive the file name.
Pointer to the
ITC_PDF417_SEGMENT_COUNT
location to receive the segment count.
Pointer to the
ITC_PDF417_TIME_STAMP location to
receive the time stamp.
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
pePdfSender
[out]
pePdfAddressee
[out]
pePdfFileSize
[out]
pePdfChecksum
[out]
Pointer to the ITC_PDF417_SENDER
location to receive the sender.
Pointer to the
ITC_PDF417_ADDRESSEE location to
receive the addressee.
Pointer to the ITC_PDF417_FILE_SIZE
location to receive the file size.
Pointer to the
ITC_PDF417_CHECKSUM location to
receive the checksum.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
IS9CConfig::SetPDF417
This function updates the PDF417 settings with new values.
Syntax
HRESULT IS9CConfig::SetPDF417( ITC_PDF417_DECODING
ePdf417Decode, ITC_PDF417_MACRO_PDF eMacroPdf,
ITC_PDF417_CTRL_HEADER ePdfControlHeader,
ITC_PDF417_FILE_NAME ePdfFileName, ITC_PDF417_SEGMENT_COUNT
ePdfSegmentCount, ITC_PDF417_TIME_STAMP ePdfTimeStamp,
ITC_PDF417_SENDER ePdfSender, ITC_PDF417_ADDRESSEE
ePdfAddressee, ITC_PDF417_FILE_SIZE ePdfFileSize,
ITC_PDF417_CHECKSUM ePdfChecksum );
Parameters
ePdf417Decode
[in] Identifies the decoding for PDF417 symbology.
eMacroPdf
[in] Identifies the Macro PDF.
ePdfControlHeader [in] Identifies the control header.
ePdfFileName
ePdfSegmentCount
ePdfTimeStamp
ePdfSender
[in]
[in]
[in]
[in]
Identifies the file name.
Identifies the segment count.
Identifies the time stamp.
Identifies the sender.
ePdfAddressee
ePdfFileSize
ePdfChecksum
[in] Identifies the addressee.
[in] Identifies the file size.
[in] Identifies the checksum.
Return Values
HRESULT that indicates success or failure.
700 Series Color Mobile Computer User’s Manual
189
Chapter 6 — Scanner Support
Remarks
None.
See Also
None.
PDF 417 Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_PDF417_DECODING
Macro PDF
Macro PDF Buffered
ITC_PDF417_MACRO_PDF
Control Header
Not Transmitted
ITC_PDF417_CTRL_HEADER
*File Name
Not Transmitted
ITC_PDF417_FILE_NAME
*Segment Count
Not Transmitted
ITC_PDF417_SEGMENT_COUNT
*Time Stamp
Not Transmitted
ITC_PDF417_TIME_STAMP
*Sender
Not Transmitted
ITC_PDF417_SENDER
*Address
Not Transmitted
ITC_PDF417_ADDRESSEE
*File Size
Not Transmitted
ITC_PDF417_FILE_SIZE
*Check Sum
Not Transmitted
ITC_PDF417_CHECKSUM
* These are Macro PDF Optional Fields.
PDF 417 Enumerations
typedef enum tagPdf417Decoding
ITC_PDF417_NOTACTIVE = 0,
ITC_PDF417_ACTIVE = 1,
//
ITC_PDF417_NO_CHANGE = 255
} ITC_PDF417_DECODING;
typedef enum tagPdf417MacroPdf
ITC_PDF417_MACRO_UNBUFFERED = 0,
ITC_PDF417_MACRO_BUFFERED = 1,
//
ITC_PDF417_MACRO_NO_CHANGE = 255
} ITC_PDF417_MACRO_PDF;
typedef enum tagPdf417ControlHeader
ITC_PDF417_CTRL_HEADER_NOTXMIT = 0,
ITC_PDF417_CTRL_HEADER_XMIT = 1,
ITC_PDF417_CTRL_HEADER_NO_CHANGE = 255
} ITC_PDF417_CTRL_HEADER;
typedef enum tagPdf417FileName
ITC_PDF417_FILE_NAME_NOTXMIT = 0,
//
ITC_PDF417_FILE_NAME_XMIT = 1,
ITC_PDF417_FILE_NAME_NO_CHANGE = 255
} ITC_PDF417_FILE_NAME;
typedef enum tagPdf417SegmentCount
ITC_PDF417_SEGMENT_COUNT_NOTXMIT = 0, //
ITC_PDF417_SEGMENT_COUNT_XMIT = 1,
190
Default
Default
// Default
Default
Default
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
ITC_PDF417_SEGMENT_COUNT_NO_CHANGE = 255
} ITC_PDF417_SEGMENT_COUNT;
typedef enum tagPdf417TimeStamp
ITC_PDF417_TIME_STAMP_NOTXMIT = 0,
//
ITC_PDF417_TIME_STAMP_XMIT = 1,
ITC_PDF417_TIME_STAMP_NO_CHANGE = 255
} ITC_PDF417_TIME_STAMP;
typedef enum tagPdf417Sender
ITC_PDF417_SENDER_NOTXMIT = 0,
//
ITC_PDF417_SENDER_XMIT = 1,
ITC_PDF417_SENDER_NO_CHANGE = 255
} ITC_PDF417_SENDER;
typedef enum tagPdf417Addressee
ITC_PDF417_ADDRESSEE_NOTXMIT = 0,
//
ITC_PDF417_ADDRESSEE_XMIT = 1,
ITC_PDF417_ADDRESSEE_NO_CHANGE = 255
} ITC_PDF417_ADDRESSEE;
typedef enum tagPdf417FileSize
ITC_PDF417_FILE_SIZE_NOTXMIT = 0,
//
ITC_PDF417_FILE_SIZE_XMIT = 1,
ITC_PDF417_FILE_SIZE_NO_CHANGE = 255
} ITC_PDF417_FILE_SIZE;
typedef enum tagPdf417Checksum
ITC_PDF417_CHECKSUM_NOTXMIT = 0,
ITC_PDF417_CHECKSUM_XMIT = 1,
ITC_PDF417_CHECKSUM_NO_CHANGE = 255
} ITC_PDF417_CHECKSUM;
700 Series Color Mobile Computer User’s Manual
Default
Default
Default
Default
// Default
191
Chapter 6 — Scanner Support
IS9CConfig::GetPlessey
This function retrieves the current Plessey settings.
Syntax
HRESULT IS9CConfig::GetPlessey( ITC_PLESSEY_DECODING*
peDecode, ITC_PLESSEY_CHECK_DIGIT* peCheck, DWORD* pdwLength
);
Parameters
peDecode
[out]
Pointer to the ITC_PLESSEY_DECODING
location to receive the decoding for Plessey
symbology.
peCheck
[out]
Pointer to the ITC_PLESSEY_CHECK_DIGIT
location to receive the check digit.
pdwLength
[out]
Pointer to the DWORD location to receive the bar
code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
IS9CConfig::SetPlessey
This function updates the Plessey settings with new values.
Syntax
HRESULT IS9CConfig::SetPlessey( ITC_PLESSEY_DECODING
eDecode, ITC_PLESSEY_CHECK_DIGIT eCheck, DWORD dwLength );
Parameters
eDecode
[in] Identifies the decoding for Plessey symbology.
eCheck
[in] Identifies the check digit.
dwLength
[in] Identifies the bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
192
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Plessey Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_PLESSEY_DECODING
Check Digit
Not Transmitted
ITC_PLESSEY_CHECK_DIGIT
Bar Code Length
Any Bar Code Length
0x00`0xFE
ITC_BC_LENGTH_NO_CHANGE
Plessey Enumerations
typedef enum tagPlesseyDecoding
ITC_PLESSEY_NOTACTIVE = 0,
// Default
ITC_PLESSEY_ACTIVE = 1,
ITC_PLESSEY_NO_CHANGE = 255
} ITC_PLESSEY_DECODING;
typedef enum tagPlesseyCheckDigit
ITC_PLESSEY_CHECK_NOTXMIT = 0,
// Default
ITC_PLESSEY_CHECK_XMIT = 1,
ITC_PLESSEY_CHECK_NO_CHANGE = 255
} ITC_PLESSEY_CHECK_DIGIT;
#define ITC_BC_LENGTH_NO_CHANGE 255. This definition can be used when the bar
code length does not require any change.
700 Series Color Mobile Computer User’s Manual
193
Chapter 6 — Scanner Support
IS9CConfig::GetStandard2of5
This function retrieves the current Standard 2 of 5 settings.
Syntax
HRESULT IS9CConfig::GetStandard2of5(
ITC_STANDARD2OF5_DECODING* peDecode,
ITC_STANDARD2OF5_FORMAT* peFormat,
ITC_STANDARD2OF5_CHECK_DIGIT* peCheck,
ITC_BARCODE_LENGTH_ID* peLengthId, BYTE rgbLengthBuff,
DWORD* pdwNumBytes );
Parameters
peDecode
[out]
Pointer to the
ITC_STANDARD2OF5_DECODING
location to receive the decoding for Standard
2 of 5 symbology.
peFormat
[out]
Pointer to the
ITC_STANDARD2OF5_FORMAT location
to receive the format.
peCheck
[out]
Pointer to the
ITC_STANDARD2OF5_CHECK_DIGIT
location to receive Modulo 10 check digit.
peLengthId
[out]
Pointer to the ITC_BARCODE_LENGTH_ID
location to receive an indicator of either
ITC_BARCODE_LENGTH or
ITC_BARCODE_FIXED_LENGTH.
rgbLengthBuff
[out,size_is(3)]
An array of bytes to receives 1 byte of data for
ITC_BARCODE_LENGTH, or 3 bytes of data
for ITC_BARCODE_FIXED_LENGTH.
pdwNumBytes
[out]
Pointer to the DWORD location to receive a
number indicating number of bytes in
rbgLengthBuff[]: 1 byte for
ITC_BARCODE_LENGTH or 3 bytes for
ITC_BARCODE_FIXED_LENGTH.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
194
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig::SetStandard2of5
This function updates the Standard 2 of 5 settings with new values.
Syntax
HRESULT IS9CConfig::SetStandard2of5(
ITC_STANDARD2OF5_DECODING eDecode, ITC_STANDARD2OF5_FORMAT
eFormat, ITC_STANDARD2OF5_CHECK_DIGIT eCheck,
ITC_BARCODE_LENGTH_ID eLengthId, BYTE rgbLengthBuff[], DWORD
dwNumBytes );
Parameters
eDecode
[in] Identifies the decoding for Standard 2 of 5
symbology.
eFormat
[in] Identifies the format.
eCheck
[in] Identifies the Modulo 10 check digit.
eLengthId
[in] Use
ITC_BARCODE_LENGTH_NO_CHANGE to
indicate no change for bar code length. Use
ITC_BARCODE_LENGTH for any length and
minimum length, and set rgbLengthBuff[0] to a
valid length value. Use
ITC_BARCODE_FIXED_LENGTH to compose
1 or 2 or 3 fixed lengths, and set 3 bytes:
rgbLengthBuff[0], rgbLengthBuff[1],
rgbLengthBuff[2] with valid values.
rgbLengthBuff
[in,size_is(dwNumBytes)]
An array of bytes containing bar code lengths when
eLengthId = ITC_BARCODE_LENGTH or
ITC_BARCODE_FIXED_LENGTH.
dwNumBytes
[in] Number of bytes in rbgLengthBuff[]. For S9C, this
value is 1 when eLengthId =
ITC_BARCODE_LENGTH or 3 when eLengthId
= ITC_BARCODE_FIXED_LENGTH.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
700 Series Color Mobile Computer User’s Manual
195
Chapter 6 — Scanner Support
Standard 2 of 5 Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_STANDARD2OF5_DECODING
Format
Identicon (6 Start/Stop bars)
ITC_STANDARD2OF5_FORMAT
Check Digit
Not Used
ITC_STANDARD2OF5_CHECK_DIGIT
Bar Code Length
Minimum Length = 6
0x00-0xFE ITC_BC_LENGTH_NO_CHANGE
Standard 2 of 5 Enumerations
typedef enum tagStandard2of5Decoding
ITC_STANDARD2OF5_NOTACTIVE = 0, // Default
ITC_STANDARD2OF5_ACTIVE = 1,
ITC_STANDARD2OF5_NO_CHANGE = 255
} ITC_STANDARD2OF5_DECODING;
typedef enum tagStandard2of5Format
ITC_STANDARD2OF5_FORMAT_IDENTICON, // Default
ITC_STANDARD2OF5_FORMAT_COMPUTER_IDENTICS,
ITC_STANDARD2OF5_FORMAT_NO_CHANGE = 255
} ITC_STANDARD2OF5_FORMAT;
typedef enum tagStandard2of5CheckDigit
ITC_STANDARD2OF5_CHECK_NOTUSED, // Default
ITC_STANDARD2OF5_CHECK_XMIT,
ITC_STANDARD2OF5_CHECK_NOTXMIT,
ITC_STANDARD2OF5_CHECK_NO_CHANGE = 255
} ITC_STANDARD2OF5_CHECK_DIGIT;
typedef enum tagBarcodeLengthId
ITC_BARCODE_LENGTH = 0,
ITC_BARCODE_FIXED_LENGTH,
ITC_BARCODE_LENGTH_NO_CHANGE = 255
} ITC_BARCODE_LENGTH_ID;
196
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig::GetTelepen
This function retrieves the current Telepen settings.
Syntax
HRESULT IS9CConfig::GetTelepen( ITC_TELEPEN_DECODING*
peDecode, ITC_TELEPEN_FORMAT* peFormat );
Parameters
peDecode
[out]
peFormat [out]
Pointer to the ITC_TELEPEN_DECODING
location to receive the decoding for TELEPEN
symbology.
Pointer to the ITC_TELEPEN_FORMAT location to
receive the format.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
IS9CConfig::SetTelepen
This function updates the Telepen settings with new values.
Syntax
HRESULT IS9CConfig::SetTelepen( ITC_TELEPEN_DECODING*
eDecode, ITC_TELEPEN_FORMAT* eFormat );
Parameters
eDecode
[in] Identifies the decoding for Telepen symbology.
eFormat
[in] Identifies the format.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
Telepen Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_TELEPEN_DECODING
Format
ASCII
ITC_TELEPEN_FORMAT
700 Series Color Mobile Computer User’s Manual
197
Chapter 6 — Scanner Support
Telepen Enumerations
typedef enum tagTelepenDecoding
ITC_TELEPEN_NOTACTIVE = 0, // Default
ITC_TELEPEN_ACTIVE = 1,
ITC_TELEPEN_NO_CHANGE = 255
} ITC_TELEPEN_DECODING;
typedef enum tagTelepenDecoding
ITC_TELEPEN_FORMAT_ASCII, // Default
ITC_TELEPEN_FORMAT_NUMERIC,
ITC_TELEPEN_FORMAT_NO_CHANGE = 255
} ITC_TELEPEN_FORMAT;
IS9CConfig::GetUpcEan
This function retrieves the current UPC/EAN settings.
Syntax
HRESULT IS9CConfig::GetUpcEan( ITC_UPCEAN_DECODING*
upceanDecode, ITC_UPCA_SELECT* upcASelect, ITC_UPCE_SELECT*
upcESelect, ITC_EAN8_SELECT* ean8Select, ITC_EAN13_SELECT*
ean13Select, ITC_UPCEAN_ADDON_DIGITS* upcAddOnDigits,
ITC_UPCEAN_ADDON_TWO* upcAddOn2, ITC_UPCEAN_ADDON_FIVE*
upcAddOn5, ITC_UPCA_CHECK_DIGIT* upcACheck,
ITC_UPCE_CHECK_DIGIT* upcECheck, ITC_EAN8_CHECK_DIGIT*
ean8Check, ITC_EAN13_CHECK_DIGIT* ean13Check,
ITC_UPCA_NUMBER_SYSTEM* upcANumSystem,
ITC_UPCE_NUMBER_SYSTEM* upcENumSystem, ITC_UPCA_REENCODE*
upcAReencode, ITC_UPCE_REENCODE* upcEReencode,
ITC_EAN8_REENCODE* ean8Reencode );
Parameters
upceanDecode
[out]
upcASelect
[out]
upcESelect
[out]
ean8Select
[out]
ean13Select
[out]
upcAddOnDigits [out]
198
upcAddOn2
[out]
upcAddOn5
[out]
Pointer to the ITC_UPCEAN_DECODING
location to receive the decoding for UPC/EAN
symbology.
Pointer to the ITC_UPCA_SELECT location to
receive the UPC-A selection state.
Pointer to the ITC_UPCE_SELECT location to
receive the UPC-E selection state.
Pointer to the ITC_EAN8_SELECT location to
receive the EAN-8 selection state.
Pointer to the ITC_EAN13_SELECT location
to receive the EAN-13 selection state.
Pointer to the
ITC_UPCEAN_ADDON_DIGITS location to
receive the add-on digits.
Pointer to the
ITC_UPCEAN_ADDON_TWO location to
receive the add-on 2 digits.
Pointer to the ITC_UPCEAN_ADDON_FIVE
location to receive the add-on 5 digits.
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
upcACheck
[out]
Pointer to the ITC_UPCA_CHECK_DIGIT
location to receive the UPC-A check digit.
upcECheck
[out]
Pointer to the ITC_UPCE_CHECK_DIGIT
location to receive the UPC-E check digit.
ean8Check
[out]
Pointer to the ITC_EAN8_CHECK_DIGIT
location to receive the EAN-8 check digit.
ean13Check
[out]
Pointer to the ITC_EAN13_CHECK_DIGIT
location to receive the EAN-13 check digit.
upcANumSystem [out]
Pointer to the
ITC_UPCA_NUMBER_SYSTEM location to
receive the UPC-A number system.
upcENumSystem [out]
Pointer to the
ITC_UPCE_NUMBER_SYSTEM location to
receive the UPC-E number system.
upcAReencode
[out]
Pointer to the ITC_UPCA_REENCODE
location to receive the UPC-A reencoding.
upcEReencode
[out]
Pointer to the ITC_UPCE_REENCODE
location to receive the UPC-E reencoding.
ean8Reencode
[out]
Pointer to the ITC_EAN8_REENCODE
location to receive the EAN-8 reencoding.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
700 Series Color Mobile Computer User’s Manual
199
Chapter 6 — Scanner Support
IS9CConfig::SetUpcEan
This function updates the UPC/EAN settings with new values.
Syntax
HRESULT IS9CConfig::SetUpcEan( ITC_UPCEAN_DECODING
upceanDecode, ITC_UPCA_SELECT upcASelect, ITC_UPCE_SELECT
upcESelect, ITC_EAN8_SELECT ean8Select, ITC_EAN13_SELECT
ean13Select, ITC_UPCEAN_ADDON_DIGITS upcAddOnDigits,
ITC_UPCEAN_ADDON_TWO upcAddOn2, ITC_UPCEAN_ADDON_FIVE
upcAddOn5, ITC_UPCA_CHECK_DIGIT upcACheck,
ITC_UPCE_CHECK_DIGIT upcECheck, ITC_EAN8_CHECK_DIGIT
ean8Check, ITC_EAN13_CHECK_DIGIT ean13Check,
ITC_UPCA_NUMBER_SYSTEM upcANumSystem, ITC_UPCE_NUMBER_SYSTEM
upcENumSystem, ITC_UPCA_REENCODE upcAReencode,
ITC_UPCE_REENCODE upcEReencode, ITC_EAN8_REENCODE
ean8Reencode );
Parameters
upceanDecode
[in] Identifies the decoding for UPC/EAN symbology.
upcASelect
[in] Identifies the UPC-A selection state.
upcESelect
[in] Identifies the UPC-E selection state.
ean8Select
[in] Identifies the EAN-8 selection state.
ean13Select
[in] Identifies the EAN-13 selection state.
upcAddOnDigits [in] Identifies the Add-on digits.
upcAddOn2
[in] Identifies the Add-on 2 digits.
upcAddOn5
[in] Identifies the Add-on 5 digits.
upcACheck
[in] Identifies the UPC-A check digit.
upcECheck
[in] Identifies the UPC-E check digit.
ean8Check
[in] Identifies the EAN-8 check digit.
ean13Check
[in] Identifies the EAN-13 check digit.
upcANumSystem [in] Identifies the UPC-A number system.
upcENumSystem [in] Identifies the UPC-E number system.
upcAReencode
[in] Identifies the UPC-A reencoding.
upcEReencode
[in] Identifies the UPC-E reencoding.
ean8Reencode
[in] Identifies the EAN-8 reencoding.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
200
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
UPC/EAN Default Settings
Parameter
Default
Valid Range
Decoding
ITC_UPCEAN_NO_CHANGE
This parameter is no longer used, set it to this value.
UPC-A
Active
ITC_UPCA_SELECT
UPC-E
Active
ITC_UPCE_SELECT
EAN-8
Active
ITC_EAN8_SELECT
EAN-13
Active
ITC_EAN13_SELECT
Add On Digits
Not Required
ITC_UPCEAN_ADDON_DIGITS
Add On 2 Digits
Not Active
ITC_UPCEAN_ADDON_TWO
Add On 5 Digits
Not Active
ITC_UPCEAN_ADDON_FIVE
UPC-A Check Digit
Transmitted
ITC_UPCA_CHECK_DIGIT
UPC-E Check Digit
Transmitted
ITC_UPCE_CHECK_DIGIT
EAN-8 Check Digit
Transmitted
ITC_EAN8_CHECK_DIGIT
EAN-13 Check Digit
Transmitted
ITC_EAN13_CHECK_DIGIT
UPC-A Number System Transmitted
ITC_UPCA_NUMBER_SYSTEM
UPC-E Number System Transmitted
ITC_UPCE_NUMBER_SYSTEM
Reencode UPC-A
UPC-A transmitted as EAN-13
ITC_UPCA_REENCODE
Reencode UPC-E
UPC-E transmitted as UPC-E
ITC_UPCE_REENCODE
Reencode EAN-8
EAN-8 transmitted as EAN-8
ITC_EAN8_REENCODE
UPC/EAN Enumerations
typedef enum tagUpcEanDecoding
ITC_UPCEAN_NOTACTIVE = 0,
ITC_UPCEAN_ACTIVE = 1,
ITC_UPCEAN_NO_CHANGE = 255
} ITC_UPCEAN_DECODING;
typedef enum tagUpcASelect
ITC_UPCA_DEACTIVATE,
ITC_UPCA_ACTIVATE,
ITC_UPCA_NO_CHANGE = 255
} ITC_UPCA_SELECT;
typedef enum tagUpcESelect
ITC_UPCE_DEACTIVATE,
ITC_UPCE_ACTIVATE,
ITC_UPCE_NO_CHANGE = 255
} ITC_UPCE_SELECT;
typedef enum tagEan8Select
ITC_EAN8_DEACTIVATE,
ITC_EAN8_ACTIVATE,
ITC_EAN8_NO_CHANGE = 255
} ITC_EAN8_SELECT;
typedef enum tagEan13Select
ITC_EAN13_DEACTIVATE,
700 Series Color Mobile Computer User’s Manual
// Default
// Default
// Default
// Default
201
Chapter 6 — Scanner Support
ITC_EAN13_ACTIVATE,
ITC_EAN13_NO_CHANGE = 255
} ITC_EAN13_SELECT;
typedef enum tagUpcEanAddonDigits
ITC_UPCEAN_ADDON_NOT_REQUIRED,
ITC_UPCEAN_ADDON_REQUIRED,
ITC_UPCEAN_ADDON_NO_CHANGE = 255
} ITC_UPCEAN_ADDON_DIGITS;
typedef enum tagUpcEanAddonTwo
ITC_UPCEAN_ADDON_TWO_NOTACTIVE = 0,
ITC_UPCEAN_ADDON_TWO_ACTIVE = 1,
ITC_UPCEAN_ADDON_TWO_NO_CHANGE = 255
} ITC_UPCEAN_ADDON_TWO;
typedef enum tagUpcEanAddonFive
ITC_UPCEAN_ADDON_FIVE_NOTACTIVE = 0,
ITC_UPCEAN_ADDON_FIVE_ACTIVE = 1,
ITC_UPCEAN_ADDON_FIVE_NO_CHANGE = 255
} ITC_UPCEAN_ADDON_FIVE;
typedef enum tagUpcACheckDigit
ITC_UPCA_CHECK_NOTXMIT = 0,
ITC_UPCA_CHECK_XMIT = 1,
ITC_UPCA_CHECK_NO_CHANGE = 255
} ITC_UPCA_CHECK_DIGIT;
typedef enum tagUpcECheckDigit
ITC_UPCE_CHECK_NOTXMIT = 0,
ITC_UPCE_CHECK_XMIT = 1,
ITC_UPCE_CHECK_NO_CHANGE = 255
} ITC_UPCE_CHECK_DIGIT;
typedef enum tagEan8CheckDigit
ITC_EAN8_CHECK_NOTXMIT = 0,
ITC_EAN8_CHECK_XMIT = 1,
ITC_EAN8_CHECK_NO_CHANGE = 255
} ITC_EAN8_CHECK_DIGIT;
typedef enum tagEan13CheckDigit
ITC_EAN13_CHECK_NOTXMIT = 0,
ITC_EAN13_CHECK_XMIT = 1,
ITC_EAN13_CHECK_NO_CHANGE = 255
} ITC_EAN13_CHECK_DIGIT;
typedef enum tagUpcANumberSystem
ITC_UPCA_NUM_SYS_NOTXMIT = 0,
ITC_UPCA_NUM_SYS_XMIT = 1,
ITC_UPCA_NUM_SYS_NO_CHANGE = 255
} ITC_UPCA_NUMBER_SYSTEM;
typedef enum tagUpcENumberSystem
ITC_UPCE_NUM_SYS_NOTXMIT = 0,
ITC_UPCE_NUM_SYS_XMIT = 1,
ITC_UPCE_NUM_SYS_NO_CHANGE = 255
} ITC_UPCE_NUMBER_SYSTEM;
typedef enum tagUpcAReencode
202
// Default
// Default
// Default
// Default
// Default
// Default
// Default
// Default
// Default
// Default
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
ITC_UPCA_XMIT_AS_EAN13,
ITC_UPCA_XMIT_AS_UPCA,
ITC_UPCA_XMIT_NO_CHANGE = 255
} ITC_UPCA_REENCODE;
typedef enum tagUpcEReencode
ITC_UPCE_XMIT_AS_UPCE,
ITC_UPCE_XMIT_AS_UPCA,
ITC_UPCE_XMIT_NO_CHANGE = 255
} ITC_UPCE_REENCODE;
typedef enum tagEan8Reencode
ITC_EAN8_XMIT_AS_EAN8,
ITC_EAN8_XMIT_AS_EAN13,
ITC_EAN8_XMIT_NO_CHANGE = 255
} ITC_EAN8_REENCODE;
700 Series Color Mobile Computer User’s Manual
// Default
// Default
//Default
203
Chapter 6 — Scanner Support
IS9CConfig2 Functions
This interface is derived from the IS9CConfig interface and provides additional methods that can be used to set and retrieve the 700 Series Computer’ s bar code configuration. All supported symbologies are initialized to
their defaults when the S9C firmware is loaded.
GET/SET functions use enumerations as their parameters. In most enumerations, there is an enumerator xx_NO_CHANGE (such as
ITC_CODE39_NO_CHANGE), where xx refers to a particular enumeration. This enumerator can be used during a call to a SET to indicate
that no change is to be made to that particular parameter. This prevents
the called function from having to format the same S9C command and
send it down to the scanner.
To specify a bar code length of “any length,” use a value of “0” for the bar
code length argument.
IS9CConfig2 functions are the following. IS9CCONFIG.H is the header
file and ITCUUID.LIB contains the IID_IADC Interface GUID value
used to obtain the interface.
S IS9CConfig2::GetCode11 (page 205)
S IS9CConfig2::SetCode11 (page 205)
S IS9CConfig2::GetCustomSymIds (page 207)
S IS9CConfig2::SetCustomSymIds (page 208)
S IS9CConfig2::GetGlobalAmble (page 211)
S IS9CConfig2::SetGlobalAmble (page 212)
S IS9CConfig2::GetPDF417Ext (page 213)
S IS9CConfig2::SetPDF417Ext (page 213)
S IS9CConfig2::GetSymIdXmit (page 214)
S IS9CConfig2::SetSymIdXmit (page 214)
204
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig2::GetCode11
This function retrieves the current settings for Code 11.
Syntax
HRESULT GetCode11( ITC_CODE11_DECODING* peDecode,
ITC_CODE11_CHECK_DIGIT* peCheck,
ITC_CODE11_CHECK_VERIFICATION* peVer );
Parameters
peDecode
[out]
Pointer to ITC_CODE11_DECODING location to
receive Code 11 decoding.
peCheck
[out]
Pointer to ITC_CODE11_CHECK_DIGIT location
to receive the check digit option.
peVer
[out]
Pointer to
ITC_CODE11_CHECK_VERIFICATION location
to receive the check verification option.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
IS9CConfig2::SetCode11
This function updates the current setting of Code 11 symbology.
Syntax
HRESULT SetCode11( ITC_CODE11_DECODING eDecode,
ITC_CODE11_CHECK_DIGIT eCheck, ITC_CODE11_CHECK_VERIFICATION
eVer );
Parameters
eDecode
[in] An enumeration that identifies decoding option for
Code 11.
eCheck
[in] An enumeration that identifies the check digit option.
eVer
[in] An enumeration that identifies check verification option.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
700 Series Color Mobile Computer User’s Manual
205
Chapter 6 — Scanner Support
Code 11 Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_CODE11_DECODING
Check Verification
1 Digit
ITC_CODE11_CHECK_VERIFICATION
Check Digit
Enable
ITC_CODE11_CHECK_DIGIT
Code 11 Enumerations
typedef enum tagCode11Decoding
ITC_CODE11_NOTACTIVE = 0,
ITC_CODE11_ACTIVE = 1, // Default
ITC_CODE11_NO_CHANGE = 255
} ITC_CODE11_DECODING;
typedef enum tagCode11CheckVerification
ITC_CODE11_CHK_VERIFY_ONEDIGIT = 1,
ITC_CODE11_CHK_VERIFY_TWODIGIT = 2, // Default
ITC_CODE11_CHK_VERIFY_NO_CHANGE = 255
} ITC_CODE11_CHECK_VERIFICATION;
typedef enum tagCode11CheckDigit
ITC_CODE11_CHECK_NOTXMIT = 0, // Default
ITC_CODE11_CHECK_XMIT = 1,
ITC_CODE11_CHECK_NO_CHANGE = 255
} ITC_CODE11_CHECK_DIGIT;
206
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig2::GetCustomSymIds
This function retrieves all the custom symbology identifiers defined for the
currently supported symbologies. This is not supported when using an imager on the 700 Series Computer.
Syntax
HRESULT GetCustomSymIds( ITC_CUST_SYM_ID_PAIR*
pStructSymIdPair,DWORD dwMaxNumElement, DWORD* pdwNumElement
);
Parameters
pStructSymIdPair
[out]
Pointer to ITC_CUST_SYM_ID_PAIR
location to receive the current defined
symbology identifiers for the supported
symbologies. The caller must preallocate
this buffer with dwMaxNumElement
elements.
dwMaxNumElement
[in]
Maximum number of elements allocated
for the pStructSymIdPair buffer which
should always be equal to the last defined
enumeration constant + 1 of the
enumeration ITC_CUSTOM_ID. In this
case, it is
ITC_CUSTOMID_LAST_ELEMENT.
pdwNumElement
[out]
Pointer to DWORD location to receive
the actual number of elements returned in
the pStructSymIdPair buffer, which should
be the same as dwMaxNumElement.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
S Custom Identifier Assignments (page 209)
S Custom Identifier Example (page 210)
S Custom Identifier Default Settings (page 210)
700 Series Color Mobile Computer User’s Manual
207
Chapter 6 — Scanner Support
IS9CConfig2::SetCustomSymIds
This function updates the symbology identifiers (any ASCII values) for the
currently supported symbologies. This is not supported when using an imager on the 700 Series Computer.
Syntax
HRESULT SetCustomSymIds( ITC_CUST_SYM_ID_PAIR*
pStructSymIdPair, DWORD dwNumElement );
Parameters
pStructSymIdPair
[in] Pointer to ITC_CUST_SYM_ID_PAIR
location, containing the new symbology
identifiers for any supported symbologies to
update.
dwNumElement
[in] Identifies the number of symbology identifiers
to update in the pStructSymIdPair buffer.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
208
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Custom Identifier Assignments
Each custom identifier is a one byte ASCII value within the range from
0x00 to 0xff. The enumerations in the ITC_CUSTOM_ID enumerator
can be used as symbology identifications in the GetCustomSymIds() and
SetCustomSymIds() functions.
typedef enum tagCustomId
ITC_CUSTOMID_CODABAR = 0
Identifies
ITC_CUSTOMID_CODE39
Identifies
ITC_CUSTOMID_CODE93
Identifies
ITC_CUSTOMID_CODE128_EAN_128
Identifies
ITC_CUSTOMID_EAN8
Identifies
ITC_CUSTOMID_EAN13
Identifies
ITC_CUSTOMID_I2OF5
Identifies
ITC_CUSTOMID_MATRIX2OF5
Identifies
ITC_CUSTOMID_MSI
Identifies
ITC_CUSTOMID_PDF417
Identifies
ITC_CUSTOMID_PLESSEY
Identifies
ITC_CUSTOMID_CODE2OF5
Identifies
ITC_CUSTOMID_TELEPEN
Identifies
ITC_CUSTOMID_UPCA
Identifies
ITC_CUSTOMID_UPCE
Identifies
ITC_CUSTOMID_CODE11
Identifies
ITC_CUSTOMID_LAST_ELEMENT
Identifies
the buffer on GetCustomSymIds
}ITC_CUSTOM_ID;
typedef struct tagCustSymbIdPair
ITC_CUSTOM_ID eSymbology;
the
the
the
the
the
the
the
the
the
the
the
the
the
the
the
the
the
Codabar symbology
Code 39 symbology
Code 93 symbology
Code 128 symbology
EAN-8 symbology
EAN-13 symbology
Interleaved 2 of 5 symbology
Matrix 2 of 5 symbology
MSI symbology
PDF 417 symbology
Plessey symbology
Standard 2 of 5 symbology
Telepen symbology
UPC-A symbology
UPC-E symbology
Code 11 symbology
last element. Use to preallocate
Identifies the symbology of interest
BYTE byteId;
ASCII value (1 byte within the range0x00 – 0xf)
}ITC_CUST_SYM_ID_PAIR;
700 Series Color Mobile Computer User’s Manual
209
Chapter 6 — Scanner Support
Custom Identifier Default Settings
Symbology
Default
Valid Range
Codabar
0x00-0xFF
Code 11
0x00-0xFF
Code 39
0x00-0xFF
Code 93
0x00-0xFF
Code128/EAN 128
0x00-0xFF
EAN-8
0xFF
0x00-0xFF
EAN-13
0x00-0xFF
Interleaved 2 of 5
0x00-0xFF
Matrix 2 of 5
0x00-0xFF
MSI
0x00-0xFF
PDF 417
0x00-0xFF
Plessey
0x00-0xFF
Standard 2 of 5
0x00-0xFF
Telepen
0x00-0xFF
UPC-A
0x00-0xFF
UPC-E
0x00-0xFF
Custom Identifier Example
The following code segment is an example of updating the UPC-E and
UPC-A symbology identifiers with new values, and then retrieving the
currently defined symbology identifiers for all the supported symbologies:
ITC_CUST_SYM_ID_PAIR oStructSymIdPair [ITC_CUSTOMID_LAST_ELEMENT];
oStructSymIdPair[0].eSymbology = ITC_CUSTOMID_UPCE;
oStructSymIdPair[0].byteId = 0x41;
// ASCII char A
oStructSymIdPair[1].eSymbology = ITC_CUSTOMID_UPCA;
oStructSymIdPair[1].byteId = 0x42;
// ASCII char B
HRESULT hr = pIS9CConfig2->SetCustomSymIds(&oStructSymIdPair[0], 2];
DWORD dwNum = 0;
HRESULT hr = pIS9CConfig2->GetCustomSymIds(&oStructSymIdPair[0],
ITC_CUSTOMID_LAST_ELEMENT, &dwNum);
210
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig2::GetGlobalAmble
This retrieves the scanner’ s current preamble or postamble setting.
Syntax
HRESULT GetGlobalAmble( ITC_GLOBAL_AMBLE_ID eAmbleId, BYTE
rgbBuffer[], DWORD dwBufferSize, DWORD* pdwBufferSize );
Parameters
eAmbleId
[in]
An enumeration of type
ITC_GLOBAL_AMBLE_ID identifies whether
the preamble or postamble setting is to be
retrieved. Only one setting can be queried at a
time.
rgbBuffer
[in]
Contains the buffer for the postamble or
preamble setting to be queried.
dwBufferSize
[in]
The maximum number of bytes that rgbBuffer
can store. Must be at least
ITC_GLOBAL_AMBLE_MAX_CHARS bytes.
pdwBufferSize
[out]
A pointer to DWORD location to store the
actual number of returned bytes in rgbBuffer.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
700 Series Color Mobile Computer User’s Manual
211
Chapter 6 — Scanner Support
IS9CConfig2::SetGlobalAmble
This function updates the scanner’ s current preamble or postamble setting
depending on the input parameters.
Syntax
HRESULT SetGlobalAmble( ITC_GLOBAL_AMBLE_ID eAmbleId, BYTE
rgbBuffer[], DWORD dwBufferSize );
Parameters
eAmbleId
[in] An enumeration of type
ITC_GLOBAL_AMBLE_ID identifies whether
the preamble or postamble setting is to be updated.
Only one setting can be updated at a time.
rgbBuffer
[in] Contains the buffer for the postamble or preamble
setting to be updated.
dwBufferSize
[in] Identifies number of bytes in rgbBuffer.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
Postamble and Preamble Defaults
Parameter
Default
Valid Range
Preamble
Null
0 to 20 ASCII characters
Postamble
Null
0 to 20 ASCII characters
212
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IS9CConfig2::GetPDF417Ext
This function is an extended function for retrieving the PDF 417 settings
not included in the IS9CConfig::GetPDF417.
Syntax
HRESULT GetPDF417Ext( ITC_MICRO_PDF417_DECODING* peDecode,
ITC_MICRO_PDF417_CODE128_EMULATION* peCode128 );
Parameters
peDecode
[out]
Pointer to ITC_MICRO_PDF417_DECODING
location to receive the Micro PDF 417 decoding.
peCode128
[out] Pointer to
ITC_MICRO_PDF417_CODE128_EMULATION*
location to receive the Micro PDF 417 Code 128
emulation option.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
IS9CConfig2::SetPDF417Ext
This function is an extended function for updating the additional PDF
417 settings not included in IS9CConfig::SetPDF417.
Syntax
HRESULT SetPDF417Ext( ITC_MICRO_PDF417_DECODING eDecode,
ITC_MICRO_PDF417_CODE128_EMULATION eCode128 );
Parameters
eDecode
[in] An enumeration that identifies decoding option for the
Micro PDF 417.
eCode128 [in] An enumeration that identifies the Code 128 emulation
option for the Micro PDF 417.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
700 Series Color Mobile Computer User’s Manual
213
Chapter 6 — Scanner Support
PDF 417 Extended: Micro PDF 417 Default Settings
Parameter
Default
Valid Range
Decoding
Not Active
ITC_MICRO_PDF417_DECODING
Code 128 Emulation
Not Active
ITC_MICRO_PDF417_CODE128_EMULATION
* These are Micro PDF 417 parameters.
IS9CConfig2::GetSymIdXmit
This function retrieves the current symbology ID transmission option as
described on the next page.
Syntax
HRESULT GetSymIdXmit( ITC_SYMBOLOGY_ID_XMIT* peSymIdXmit );
Parameters
peSymIdXmit
[out]
Pointer to ITC_SYMBOLOGY_ID_XMIT
location to receive the current symbology
identifier transmission option.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
IS9CConfig2::SetSymIdXmit
This updates the symbology ID transmission option shown next page.
Syntax
HRESULT SetSymIdXmit( ITC_SYMBOLOGY_ID_XMIT eSymIdXmit );
Parameters
eSymIdXmit
[in] Identifies the symbology identifier transmission
option to update.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.
214
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Symbology ID Transmission Option
The symbology identifier (or code mark) concept provides a standardized
way for a device receiving data from a bar code reader to differentiate between the symbologies.
The following symbology ID transmission option specifies whether or not
the symbology ID should be transmitted as part of the scanned bar code
label to all the connected data collection applications. Options for transmission are: do not transmit, transmit the standard AIM identifiers, or
transmit the one byte custom defined identifiers. AIM and custom identifiers cannot be selected to be transmitted at the same time; only the last
selected option will be active.
typedef enum tagSymbologyIdXmit
ITC_ID_XMIT_DISABLE = 0
Symbology identifier will not be transmitted as part of the
label. This is the default setting.
ITC_ID_XMIT_CUSTOM = 1
Activate custom symbology identifier transmission for all
symbologies. Example of the transmitted label:
[preamble] [Custom ID]  [postamble]
ITC_ID_XMIT_AIM = 2
Activate AIM symbology identifier transmission for all
symbologies. Example of the transmitted label:
[preamble] [AIM symbology ID]  [postamble]
}ITC_SYMBOLOGY_ID_XMIT;
700 Series Color Mobile Computer User’s Manual
215
Chapter 6 — Scanner Support
IS9CConfig3 Functions
The IS9CConfig3 interface provides generic methods for retrieving and
setting configuration using ISCP commands.
ISCP Commands
An ISCP Command is composed of three or more bytes formatted as
 where:
S SG
Setup group.
S FID
Function ID.
S parameters One or more configuration value bytes depending on the
configuration.
ISCP commands include the following:
Imager Settings
This dictates the start and end column positions for the image dimension.
SG
0x7B
0x7B
FID
80
81
Parameter
Value [0..639]
Value [0..639]
Description
Start column position.
End column position.
Trigger Settings
This sets the duration of the aiming beam before acquiring images to be
decoded.
SG
0x70
FID
81
Parameter
Value [0..65535]
Description
Number of milliseconds.
QRCode Symbology
This enables or disables the QRCode symbology.
SG
0x55
0x55
FID
40
40
Parameter
Description
Disable this symbology.
Enable this symbology.
Data Matrix Symbology
This enables or disables the Data Matrix symbology.
SG
0x54
0x54
216
FID
40
40
Parameter
Description
Disable this symbology.
Enable this symbology.
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
ISCP::GetConfig
This retrieves configurations using the ISCP commands format.
Syntax
HRESULT ISCPGetConfig( BYTE rgbCommandBuff[], DWORD
dwCommandBuffSize, BYTE rgbReplyBuff[], DWORD
dwReplyBuffMaxSize, DWORD *pdwReplyBuffSize );
Parameters
rgbCommandBuff
[in, size_is]
Contains ISCP commands in
array of bytes.
dwCommandBuffSize [in]
Number of bytes in
rgbCommandBuff.
rgbReplyBuff
[in, out, size_is]
Results of query in array of
bytes.
dwReplyBuffMaxSize
[in]
Maximum size of rgdReplyBuff.
pdwReplyBuffSize
[in, out]
Number of bytes placed in
rbfReplyBuff.
Return Values
None.
Remarks
None.
See Also
None.
700 Series Color Mobile Computer User’s Manual
217
Chapter 6 — Scanner Support
ISCP::SetConfig
This updates configurations using the ISCP commands format.
Syntax
HRESULT ISCPSetConfig( BYTE rgbCommandBuff[], DWORD
dwCommandBuffSize, BYTE rgbReplyBuff[], DWORD
dwReplyBuffMaxSize, DWORD *pdwReplyBuffSize );
Parameters
rgbCommandBuff
[in, size_is]
Contains ISCP commands in
array of bytes.
dwCommandBuffSize [in]
Number of bytes in
rgbCommandBuff.
rgbReplyBuff
[in, out, size_is]
Results of request in array of
bytes.
dwReplyBuffMaxSize
[in]
Maximum size of rgbReplyBuff.
pdwReplyBuffSize
[in, out]
Number of bytes placed in
rgbReplyBuff.
Return Values
None.
Remarks
None.
See Also
None.
218
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
AIM Symbology ID Defaults
Refer to the official AIM documentation on symbology identifiers for full
information on the different processing options supported.
Symbology
ID Character Modifier Characters
Codabar
Standard Codabar symbol. No special processing.
ABC Codabar (American Blood commission)
concatenate/message append performed.
Reader has validated the check character.
Reader has stripped the check character before transmission.
Code 11
Single modulo 11 check character validated and transmitted.
Two modulo 11 check characters validated and transmitted.
Check characters validated but not transmitted.
Code 39
No check character validation nor full ASCII processing. All data
transmitted as decoded.
Modulo 43 check character validated and transmitted.
Modulo 43 check character validated but not transmitted.
Full ASCII character conversion performed. No check character
validation.
Full ASCII character conversion performed. Modulo 43 check
character validated and transmitted.
Full ASCII character conversion performed. Modulo 43 check
character validated but not transmitted.
Code 93
No options specified. Always transmit 0.
Code128
Standard data packet. No FNC1 in first or second symbol
character position after start character.
EAN/UCC-128 data packet. FNC1 in first symbol character
position after start character.
FNC1 in second symbol character position after start character.
Concatenation according to International Society for Blood
Transfusion specifications was performed. Concatenated data
follows.
Interleaved 2 of 5
Matrix 2 of 5
0`F
No check character validation.
Modulo 10 symbol check character validated and transmitted
Modulo 10 symbol check character validated but not transmitted.
For symbologies or symbology options not listed, a code character
with the value 0-F may be assigned by the decoder manufacturer
to identify those symbologies and options implemented in the
reader.
MSI
Modulo 10 symbol check character validated and transmitted.
Modulo 10 symbol check character validated but not transmitted.
700 Series Color Mobile Computer User’s Manual
219
Chapter 6 — Scanner Support
Symbology (continued)
ID Character
Modifier Characters
PDF 417/
Micro PDF 417
Reader set to conform with protocol defined in 1994 PDF 417
specifications.
Reader set to follow protocol of ENV 12925 for Extended
Channel Interpretation (all data characters 92 doubled).
Reader set to follow protocol of ENV 12925 for Basic Channel
Interpretation (data characters 92 are not doubled).
Code 128 emulation: implied FNC1 in first position.
Code 128 emulation: implied FNC1 after initial letter or pair of
digits.
Code 128 emulation: no implied FNC1.
Plessey
No options specified. Always transmit 0.
Standard 2 of 5
(2-bar start/stop)
No check character validation.
Modulo 7 check character validated and transmitted.
Modulo 7 check character validated but not transmitted.
Standard 2 of 5
(3-bar start/stop)
No options specified. Always transmit 0.
Telepen
Full ASCII mode
Double density numeric only mode
Double density numeric followed by full ASCII
Full ASCII followed by double density numeric
UPC/EAN
Consider UPC/EAN symbols with supplements as two separate symbols. The first symbol is the main data packet, and the second symbol
is the 2 or 5 digit supplement. Transmit these two symbols separately,
each with its own symbology identifier. Provision is made for the option of transmitting both symbols as a single data packet.
0 Standard data packet in full EAN format (13 digits for EAN-13,
UPC-A, and UPC-E; does not include add-on data).
1 Two digit add-on data only.
2 Five digit add-on data only.
3 Combined data packet comprising 13 digits from EAN-13,
UPC-A, or UPC-E symbol and 2 or 5 digits from add-on symbol.
4 EAN-8 data packet
IMPORTANT: The “symbology_id” character letter must be uppercase for the above definitions.
220
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IImage Interface
The IImage interface gives the application the capability to acquire images.
The image acquired can be either a raw image as captured by the digital
camera or it can be normalized. A normalized image is presented the same
as if the picture were taken at right angles to the image and at the same
distance. The normalized image is commonly used for signature capture
applications.
S IImage::ReadSigCapBuffer (page 221)
S IImage::ReadSigCapFile (page 224)
S IImage::ReadImage (page 225)
S IImage::CancelReadImage (page 226)
S IImage::Start (page 226)
S IImage::Stop (page 227)
S IImage::Open (page 227)
S IImage::Close (page 228)
IImage::ReadSigCapBuffer
Syntax
HRESULT IImage::ReadSigCapBuffer( ITC_SIGCAP_SPEC
*pSigCapSpec, ITC_IMAGE_SPEC *pImgBuffer, DWORD nMaxBuffSize
);
Parameters
Parameters:
pSigCapSpec
[in] Pointer to the structure that identifies the signature
capture region. This structure is defined as follows:
typedef struct tagITCSigCapSpec
DWORD dwStructSize;
INT iAspectRatio;
INT iOffsetX;
INT iOffsetY;
UINT uiWidth;
UINT uiHeight;
INT iResolution;
ITCFileFormat eFormat;
DWORD eDepth;
} ITC_SIGCAP_SPEC;
where:
S dwStructSize
Size, in bytes, of this struct. This is for version control.
S iAspectRatio
Ratio of the bar code height (linear bar codes) or row
height (2D bar codes) to the narrow element width.
S iOffsetX
Offset in X direction, relative to barcode center.
Positive values are right of the bar code, negative
values to the left.
700 Series Color Mobile Computer User’s Manual
221
Chapter 6 — Scanner Support
S iOffsetY
Offset in Y direction, relative to barcode center.
Positive values are higher than the bar code, negative
values lower.
Width of signature capture image region in intelligent
bar code units.
Height of the signature capture image region in
intelligent bar code units.
Number of pixels per intelligent bar code unit.
Format of the image buffer returned as follows.
Currently, only ITC_FILE_RAW is supported.
S uiWidth
S uiHeight
S iResolution
S eFormat
ITC_FILE_KIM =
ITC_FILE_TIFF_BIN =
ITC_FILE_TIFF_BIN_GROUP4 =
ITC_FILE_TIFF_GRAY_SCALE =
ITC_FILE_RAW =
ITC_FILE_JPEG =
S eDepth
pImgBuffer
0,
1,
2,
3,
4,
5,
//
//
//
//
//
//
Returns data a KIM file
TIFF Binary file
TIFF Binary Group 4 compressed
TIFF Gray Scale
Raw image
JPEG image
Number of bits per pixel. Currently, only one
(monochrome) or eight (gray-scale) are supported.
[out] Pointer to the buffer in which the signature capture
image will be put.
typedef struct tagITCImageSpec
DWORD dwStructSize;
LONG biWidth;
LONG biHeight;
WORD biBitCount;
ITC_FILE_FORMAT eFormat;
DWORD biActualImageSize;
DWORD biMaxImageBytes;
BYTE rgbImageData[1];
} ITC_IMAGE_SPEC;
where:
S dwStructSize
biWidth
biHeight
biBitCount
eFormat
biActualImageSize
biMaxImageBytes
S rgbImageData
222
Size, in bytes, of this struct. This is for version
control.
The width of each row in pixels.
The number of rows in the image data.
The number of bits per pixel.
Identifies the image format.
Total bytes of image data returned.
Maximum bytes that can be stored in
rgbImageData[].
Buffer containing the actual data, for example a
640x480 uses a 307200-byte buffer. The array size
of this buffer is arbitrary so do not use this
structure directly to reserve memory. The actual
dimension of the buffer is identified by
biMaxImageBytes.
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Return Values
HRESULT identifying success or error. On error, the following codes will
be returned:
S S_OK
Image successfully returned.
S ITC_RESULT_ERR_BADREGION_E
The specified region is not in the image.
S ITC_RESULT_NO_BC_DECODED_E
A bar code has not yet been decoded or the last bar code decoded was
not a signature capture symbology.
S ITC_IMGBUFF_TOO_SMALL_E
pImgBuffer is too small to contain the signature captured image.
S ITC_INV_PARAMETER_E
One of the parameters is invalid.
S S_DEVICE_NOT_OPENED_E
The device had not been opened.
Remarks
ReadSigCapBuffer() will return the image from the last decoded label with
dimensions identified by the calling parameter. This signature capture
region must include the signature capture bar code. The supported bar
codes for signature capture are: PDF 417, Code 128, and Code 39. The
caller specifies the width, height, and center of the image to be retrieved.
This image is independent of any rotation of the bar code relative to the
imager. Thus, if the bar code is decoded with the code itself upside down
to the imager, the retrieved image will still be right side up. However, if
the specified image is outside the field of view a result code of
ITC_RESULT_ERR_BADREGION_E will be returned.
This function uses the dimensions of the last decoded bar code as its coordinate system. Thus, all the parameters describing the image size and position are in units called “Intelligent Bar Code Units.” An Intelligent Bar
Code Unit is equivalent to the narrow element width of the bar code.
The dimensions of the resulting image can be calculated with this formula:
Resulting Width = Specified Width * Specified Resolution
Resulting Height = Specified Height * Specified Resolution
See Also
None.
700 Series Color Mobile Computer User’s Manual
223
Chapter 6 — Scanner Support
IImage::ReadSigCapFile
Note: This has not been implemented as of this publication.
Syntax
HRESULT IImage::ReadSigCapFile( ITC_SIGCAP_SPEC
*pSigCapSpec, LPCTSTR pszFileName );
Parameters
pSigCapSpec
[in] Pointer to the structure that identifies the signature
capture region. See ReadSigCapFile (page 221) for
a description of this structure.
pszFileName
[in] Name of the file in which to copy the image.
Return Values
HRESULT identifying success or error. On error, the following codes will
be returned:
S S_OK
Image successfully returned.
S ITC_RESULT_ERR_BADREGION_E
The specified region is not in the image.
S ITC_RESULT_NO_BC_DECODED_E
A bar code has not yet been decoded or the last bar code decoded was
not a signature capture symbology.
S ITC_FILE_OPEN_E
The file could not be opened.
S ITC_INV_PARAMETER_E
One of the parameters is invalid.
S S_DEVICE_NOT_OPENED_E
The device had not been opened.
Remarks
ReadSigCapFile() will write the image from the last decoded label with dimensions identified by the calling parameter. If the file already exists, its
contents will be overwritten.
This signature capture region must include the signature capture bar code.
The supported bar codes for signature capture are: PDF 417, Code 128,
and Code 39. The caller specifies the width, height, and center of the
image to be retrieved. This image is independent of any rotation of the bar
code relative to the imager. Thus, if the bar code is decoded with the code
itself upside down to the imager, the retrieved image will still be right side
up. However, if the specified image is outside the field of view a result
code of ITC_RESULT_ERR_BADREGION_E will be returned.
This function uses the dimensions of the last decoded bar code as its coordinate system. Thus, all the parameters describing the image size and position are in units called “Intelligent Bar Code Units”. An Intelligent Bar
Code Unit is equivalent to the narrow element width of the bar code.
224
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
The dimensions of the resulting image can be calculated with this formula:
Resulting Width = Specified Width * Specified Resolution
Resulting Height = Specified Height * Specified Resolution
See Also
None.
IImage::ReadImage
Syntax
HRESULT IImage::Read( ITCFileFormat eFormat, DWORD nDepth,
ITC_IMAGE_SPEC *pImgBuffer, DWORD dwTimeout );
Parameters
eFormat
ITC_FILE_KIM =
ITC_FILE_TIFF_BIN =
ITC_FILE_TIFF_BIN_GROUP4 =
ITC_FILE_TIFF_GRAY_SCALE =
ITC_FILE_RAW =
ITC_FILE_JPEG =
[in]
0,
1,
2,
3,
4,
5,
//
//
//
//
//
//
Format of the image buffer returned as follows.
Currently, only ITC_FILE_RAW is supported.
Returns data a KIM file
TIFF Binary file
TIFF Binary Group 4 compressed
TIFF Gray Scale
Raw image
JPEG image
nDepth
[in]
Number of bits per pixel. Currently, only eight
(gray-scale) are supported.
pImgBuffer
[in/out] Pointer to the buffer containing the image.
dwTimeout
[in]
Milliseconds to wait for the image to be returned.
Return Values
HRESULT identifying success or error. On error, these will be returned:
S S_OK
Image successfully returned.
S ITC_IMGBUFF_TOO_SMALL_E pImgBuffer is too small to contain
the signature captured image.
S ITC_TIMEOUT_E
Timeout.
S ITC_INV_PARAMETER_E
One of the parameters is invalid.
S S_DEVICE_NOT_OPENED_E
The device had not been opened.
Remarks
The image is returned in pImgBuffer in the caller specified format.
See Also
None.
700 Series Color Mobile Computer User’s Manual
225
Chapter 6 — Scanner Support
IImage::CancelReadImage
Syntax
HRESULT IImage::CancelReadImage( );
Parameters
None.
Return Values
Status code indicating success or failure as follows:
S S_OK
Imager closed.
S S_DEVICE_NOT_OPENED_E
The device had not been opened.
Remarks
This function causes a pending image read of IImage::ReadImage() to return immediately with an error status. The purpose of this function is to
allow the application to release a thread blocked on the ReadImage() call.
See Also
None.
IImage::Start
Syntax
HRESULT IImage::Start( );
Parameters
None.
Return Values
Status code indicating success or failure as follows:
S S_OK
Imager started.
S S_DEVICE_NOT_OPENED_E
The device had not been opened.
Remarks
This function starts the image continuously capturing images.
See Also
None.
226
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
IImage::Stop
Syntax
HRESULT IImage::Stop( );
Parameters
None.
Return Values
Status code indicating success or failure as follows:
S S_OK
Imager started.
S S_IMG_NOT_PRESENT_E
Unit does not contain an imager.
S S_DEVICE_NOT_OPENED_E
Device had not been opened.
Remarks
This function stops the image continuously capturing images.
See Also
None.
IImage::Open
Syntax
HRESULT IImage::Open( BOOL fSigCapEnable );
Parameters
fSigCapEnable
[in] When TRUE, signature capture is enabled. When
FALSE, it is disabled. Bar code labels are decoded
and images (via IImage::ReadImage) the same.
Return Values
Status code indicating success or failure as follows:
S S_OK
Imager opened.
S S_IMG_NOT_PRESENT_E
Unit does not contain an imager.
S S_DEVICE_CONTENTION_E
Device has already been opened.
Remarks
This function exclusively allocates the imager device so that the other IImage methods can be safely called.
See Also
None.
700 Series Color Mobile Computer User’s Manual
227
Chapter 6 — Scanner Support
IImage::Close
Syntax
HRESULT IImage::Close( );
Parameters
None.
Return Values
Status code indicating success or failure as follows:
S S_OK
Imager closed.
S S_DEVICE_NOT_OPENED_E
The device had not been opened.
Remarks
This function releases the imager device so that other applications can
open it. An IImage::Release() will also close the imager device.
See Also
None.
228
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Data Collection Configuration
Scanner settings for the 700 Series Computer can be configured via the
Data Collection control panel applet. From the 700 Series Computer, tap
Start → Settings → the System tab → the Data Collection icon. See Appendix A, “Control Panel Applets” for more information about the following
parameters. Note that these are in alphabetical order.
S Codabar (page 292)
S Code 11 (page 306)
S Code 128 (page 295)
S Code 128 Options (page 296)
S Code 128 FNC1 Character (page 297)
S Code 39 (page 290)
S Code 93 (page 294)
S Code 93 Length (page 294)
S Data Matrix (page 308)
S Interleaved 2 of 5 (page 303)
S Matrix 2 of 5 (page 304)
S MSI (page 299)
S PDF 417 (page 300)
S Macro PDF (page 300)
S Micro PDF 417 (page 302)
S Plessey (page 298)
S QR Code (page 307)
S Standard 2 of 5 (page 291)
S Telepen (page 305)
S UPC/EAN (page 293)
700 Series Color Mobile Computer User’s Manual
229
Chapter 6 — Scanner Support
Tethered Scanner
The Intermec Tethered Scanner feature accepts data from the COM1 port
wedges it to the keyboard interface, and allows some ADC. This feature
can be enabled or disabled from the Today Screen on the 700 Series Computer.
Enabling and Disabling
On the 700 Series Computer, tap Start → Today. Tap the bar code scanner icon in the System Tray (circled in the following illustration). Initially,
the bar code scanner icon indicates that this feature is disabled (shown to
the left).
S Select Comm Port Wedge to send any data, coming into the 700 Series
Computer through the COM1 port from an external input device, as
keyboard data to an application on the desktop.
For example, if you have Pocket Word running on your 700 Series
Computer desktop, information scanned with a scanner connected to
the COM1 port will appear in the Word document. If another data
collection application is running and is active on the 700 Series Computer, the scanned information will appear in that application.
Note: When Comm Port Wedge is selected, regardless of the data sent by
the external input device, you cannot control the device or the data format
using any of the Intermec scanner control or data transfer APIs from the
SDK or the internal Data Collection software. The external input device is
governed by what software it has onboard to tell it how to scan, take pictures, or send the data elsewhere.
230
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
S Select 1551/1553 to enable the Sabre 1551E or 1553 Tethered Scanner
to scan, then send data as keyboard data. The 1551/1553 Tethered
Scanner has software onboard that translates scanned data into characters, so the running/active application does not need to know how to do
that. All the scanner control and data transfer APIs will work with the
1551/1553 Tethered Scanner, so you can control the device.
S Select Disable All to disable this feature and use the COM1 port for
another application, such as ActiveSync. An error message will result if
this option were not selected, but this action was attempted. Similarly, if
ActiveSync is using the COM1 port, and you select Comm Port Wedge
or 1551/1553, an error message will result. See “Error Message” on page
232 for more information.
Changing Comm Settings
Tap Change Comm Settings to configure the settings for the COM1 port.
Current settings are restored after a warm-boot, but are lost after a coldboot. When these settings have not been changed, the OK button is disabled (grayed out). When changes are made, tap OK after it is enabled to
accept these changes.
S Baud Rate:
1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200
S Data Bits:
7 or 8
S Parity:
None, Odd, Even, Mark, Space
S Stop Bits:
1 or 2
S Flow Control: None or Hardware
Tethered Scanner
The default settings for the Tethered Scanner are shown in the following
illustration:
700 Series Color Mobile Computer User’s Manual
231
Chapter 6 — Scanner Support
Sabre 1551E or 1553 Tethered Scanner
The default communication configuration for the Sabre 1551E or 1553
Tethered Scanner is shown in the following illustration. Scan the EasySet
Reset Factory Defaults label to set the Sabre 1551E or 1553 tethered scanner communications settings to this configuration. The COM1 port configuration settings must also match those of the scanner to scan labels.
Welch Allyn 1470 Imager Settings
The Welch Allyn 1470 Imager can be set to this configuration by scanning
the Factory Default Settings label.
Error Message
If the COM1 port is used by another application, such as ActiveSync, neither the Comm Port Wedge nor the 1551/1553 Tethered Scanner can be
enabled. As a result, the following message may appear. Note that this message is for the Comm Port Wedge. You must disable that application to free
up the COM1 port before you can enable either the wedge or the scanner.
Scanner Cabling
A null modem cable is required for the Welch Allyn 1470 Imager to communicate with the 700 Series Computer when using the 700 Series Serial
Cable (P/N: 226-999-001).
The Sabre 1551E / 1553 Cable connects directly to the Model 700 Comm
Port.
232
700 Series Color Mobile Computer User’s Manual
Chapter 6 — Scanner Support
Limitations and Capabilities
The Tethered Scanner has the following limitations:
S No auto detection of a scanner’ s physical connection to COM1 port.
User needs to ensure the communication settings of COM1 port
matched the settings of the device.
S The Pocket PC Pocket Office applications misbehave when control
characters such as carriage return are wedged. This is a known Pocket
PC problem, which is being worked with Microsoft and for which a
work around is being developed.
S Communications port is COM1 and cannot be changed.
S A complete bar code label is detected when the time between bytes (the
inter-byte gap) exceeds 100 ms. This allows that data could be concatenated if two labels were received while the Comm Port Wedge or the
1551/1553 Tethered Scanner was not performing a read. That is, it
could be wedging data just read or the read thread could be preempted.
Also, the labels could appear concatenated if the scanner itself were to
buffer the labels before transmitting them.
When enabled, the Comm Port Wedge menu option has the following
limitation:
S There is no bar code API to get bar code data from the bar code scanner. The Comm Port Wedge transmits the data through the keyboard
interface only.
When enabled, the 1551/1553 menu option has the following capabilities:
S Grid Data Editing is available.
S The source of the symbology configurations is only available via the
Easy Set command labels. Only the Virtual Wedge configurations can be
configured via the Data Collection Control Panel Applet Virtual Wedge
page. See Appendix A, “Control Panel Applets,” for more information.
S May transmit the data through the keyboard interface (via the Virtual
Wedge).
700 Series Color Mobile Computer User’s Manual
233
Chapter 6 — Scanner Support
S The bar code APIs, defined in the IADC interface, are available to get
bar code data from the bar code scanner. The following example shows
how to programmatically collects bar code data:
#include “IADC.h”
#include “ITCAdcMgmt.h”
// Linked with ITCUUID.LIB
// Linked with ITCAdcDevMgmt.lib
IADC* pIADC;
HRESULT hrStatus = S_OK;
// Create a ADC COM interface to collect bar code data from the 1551E/1553
// when the 1551/1553 menu option is enabled.
hrStatus =
ITCDeviceOpen(TEXT(“ExtScanner”), // Name of the ADC device.
IID_IADC,
// COM interface to return
ITC_DHDEVFLAG_READAHEAD,
// Device’s Flags
(LPVOID *) &pIADC);
// the returned interface
if( SUCCEEDED(hrStatus) )
BYTE byteBuffer[MAX_LABEL_SIZE];
DWORD dwLength = 0;
HRESULT hr = pIDC->Read(
byteBuffer,
MAX_LABEL_SIZE,
&dwLength,
NULL,
INFINITE
);
//
//
//
//
//
Buffer to put the ADC data.
Size of pDataBuffer in bytes.
Number bytes returned.
Time stamp of the received data. NULL.
Number of milliseconds to wait.
when done using this COM interface, delete it:
ITCDeviceClose( (IUnknown **) pIADC);
234
700 Series Color Mobile Computer User’s Manual
7
Programming
The following programming information pertains to the 700 Series Color
Mobile Computer:
S Creating CAB Files (page 236)
S FTP Server (page 251)
S Full Screen (page 262)
S Kernel I/O control functions (page 264)
S Reboot Functions (page 280)
S Remapping the Keypad (page 281)
700 Series Color Mobile Computer User’s Manual
235
Chapter 7 — Programming
Creating CAB Files
The Windows CE operating system uses a .CAB file to install an application on a Windows CE-based device. A .CAB file is composed of multiple
files that are compressed into one file. Compressing multiple files into one
file provides the following benefits:
S All application files are present.
S A partial installation is prevented.
S The application can be installed from several sources, such as a desktop
computer or a Web site.
Use the CAB Wizard application (CABWIZ.EXE) to generate a .CAB file
for your application.
Creating Device-Specific CAB Files
Do the following to create a device-specific .CAB file for an application, in
the order provided:
1 Create an .INF file with Windows CE-specific modifications (page 236).
2 Optional Create a SETUP.DLL file to provide custom control of the
installation process (page 248).
3 Use the CAB Wizard to create the .CAB file, using the .INF file, the
optional SETUP.DLL file, and the device-specific application files as
parameters (page 249).
Creating an .INF File
An .INF file specifies information about an application for the CAB Wizard. Below are the sections of an .INF file:
[Version]
This specifies the creator of the file, version, and other relevant information.
Required? Yes
S Signature:
“signature_name”
Must be “$Windows NT$” as Windows CE is not available on Windows 95.
S Provider:
“INF_creator”
The company name of the application, such as “Microsoft.”
S CESignature:
“$Windows CE$”
EXAMPLE:
[Version]
Signature = “$Windows NT$”
Provider = “Microsoft”
CESignature = “$Windows CE$”
236
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
[CEStrings]
This specifies string substitutions for the application name and the default
installation directory.
Required? Yes
S AppName: app_name
Name of the application. Other instances of %AppName% in the .INF
file will be replaced with this string value, such as RP32.
S InstallDir: default_install_dir
Default installation directory on the device. Other instances of %InstallDir% in the .INF file will be replaced with this string value. Example:
\storage_card\%AppName%
EXAMPLE:
[CEStrings]
AppName=“Game Pack”
InstallDir=%CE1%\%AppName%
[Strings]
This section is optional and defines one or more string keys. A string key
represents a string of printable characters.
Required? No
S string_key: value
String consisting of letters, digits, or other printable characters. Enclose
value in double quotation marks ““”” if the corresponding string key is
used in an item that requires double quotation marks. No string_keys is
okay.
EXAMPLE:
[Strings]
reg_path = Software\Microsoft\My Test App
700 Series Color Mobile Computer User’s Manual
237
Chapter 7 — Programming
[CEDevice]
Describes the platform for the targeted application. All keys in this section
are optional. If a key is nonexistent or has no data, Windows CE does not
perform any checking with the exception being UnsupportedPlatforms. If
the UnsupportedPlatforms key exists but no data, the previous value is not
overridden.
Required? Yes
S ProcessorType :
processor_type
The value that is returned by SYSTEMINFO.dwProcessorType. For
example, the value for the SH3 CPU is 10003 and the MIPS CPU is
4000.
S UnsupportedPlatforms: platform_family_name
This lists known unsupported platform family names. If the name
specified in the [CEDevice.xxx] section is different from that in the
[CEDevice] section, both platform_family_name values are unsupported
for the microprocessor specified by xxx. That is, the list of unsupported
platform family names is appended to the previous list of unsupported
names. Application Manager will not display the application for an
unsupported platform. Also, a user will be warned during the setup
process if the .CAB file is copied to an unsupported device.
EXAMPLE:
[CEDevice]
UnsupportedPlatforms = pltfrm1 ; pltfrm1 is unsupported
[CEDevice.SH3]
UnsupportedPlatforms = ; pltfrm1 is still unsupported
S VersionMin:
minor_version
Numeric value returned by OSVERSIONINFO.dwVersionMinor. The
.CAB file is valid for the currently connected device if the version of this
device is greater than or equal to VersionMin. For Windows CE Japanese language devices, set this to 2.01
S VersionMax:
major_version
Numeric value returned by OSVERSIONINFO.dwVersionMajor. The
.CAB file is valid for the currently connected device if the version of this
device is less than or equal to VersionMax. For Windows CE Japanese
language devices, set this to 2.01
Note: Supported Windows CE operating system versions include 1.0,
1.01, 2.0, 2.01, and 2.10. When using these numbers, be sure to include
all significant digits.
S BuildMin:
build_number
Numeric value returned by OSVERSIONINFO.dwBuildNumber. The
.CAB file is valid for the currently connected device if the version of this
device is greater than or equal to BuildMin.
S BuildMax:
build_number
Numeric value returned by OSVERSIONINFO.dwBuildNumber. The
.CAB file is valid for the currently connected device if the version of this
device is less than or equal to BuildMax.
238
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
EXAMPLE:
The following code example shows three [CEDevice] sections: one that
gives basic information for any CPU and two that are specific to the SH3
and the MIPS microprocessors.
[CEDevice]
; A “template” for all platforms
UnsupportedPlatforms = pltfrm1 ; Does not support pltfrm1
; The following specifies version 1.0 devices only.
VersionMin = 1.0
VersionMax = 1.0
[CEDevice.SH3]
; Inherits all [CEDevice] settings
; This will create a .CAB file specific to SH3 devices.
ProcessorType = 10003
; SH3 .cab file is valid for SH3 microprocessors.
UnsupportedPlatforms =
; pltfrm1 is still unsupported
; The following overrides the version settings so that no version checking is
performed.
VersionMin =
VersionMax =
[CEDevice.MIPS]
; This will create a .CAB file
ProcessorType = 4000
UnsupportedPlatforms =pltfrm2
; Inherits all [CEDevice] settings
specific to “MIPS” devices.
; MIPS .CAB file is valid for MIPS microprocessor.
; pltfrm1, pltfrm2 unsupported for MIPs .CAB file.
Note: To create the two CPU-specific .CAB files for the SETUP.INF file
in the previous example, run the CAB Wizard with the “/cpu sh3 mips”
parameter.
700 Series Color Mobile Computer User’s Manual
239
Chapter 7 — Programming
[DefaultInstall]
This describes the default installation of your application. Note that under
this section, you will list items expanded upon later in this description.
Required? Yes
S Copyfiles:
copyfile_list_section
Maps to files defined later in the .INF file, such as Files.App, Files.Font,
and Files.Bitmaps.
S AddReg:
add_registry_section
Example: RegSettings.All
S CEShortcuts:
shortcut_list_section
String that identifies one more section that defines shortcuts to a file, as
defined in the [CEShortcuts] section.
S CESetupDLL:
setup_DLL
Optimal string that specifies a SETUP.DLL file. It is written by the Independent Software Vendor (ISV) and contains customized functions
for operations during installation and removal of the application. The
file must be specified in the [SourceDisksFiles] section.
S CESelfRegister:
self_reg_DLL_filename
String that identifies files that self-register by exporting the DllRegisterServer and DllUnregisterServer Component Object Model (COM)
functions. Specify these files in the [SourceDiskFiles] section. During
installation, if installation on the device fails to call the file’ s exported
DllRegisterServer function, the file’ s exported DllUnregisterServer
function will not be called during removal.
EXAMPLE:
[DefaultInstall]
AddReg = RegSettings.All
CEShortcuts = Shortcuts.All
[SourceDiskNames]
This section describes the name and path of the disk on which your application resides.
Required? Yes
S disk_ordinal:
disk_label,,path
1=,“App files” , C:\Appsoft\RP32\...
2=,“Font files”,,C:\RpTools\...
3=,“CE Tools” ,,C:\windows ce tools...
S CESignature:
“$Windows CE$”
Example
[SourceDisksNames]
1 = ,“Common files”,,C:\app\common
[SourceDisksNames.SH3]
2 = ,“SH3 files”,,sh3
[SourceDisksNames.MIPS]
2 = ,“MIPS files”,,mips
240
; Required section
; Using an absolute path
; Using a relative path
; Using a relative path
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
[SourceDiskFiles]
This describes the name and path of the files in which your application
resides.
Required? Yes
S filename:
disk_number[,subdir]
RPM.EXE = 1,c:\appsoft\...
WCESTART.INI = 1
RPMCE212.INI = 1
TAHOMA.TTF = 2
Note: [,subdir] is relative to the location of the INF file.
Example
[SourceDisksFiles]
; Required section
begin.wav = 1
end.wav = 1
sample.hlp = 1
[SourceDisksFiles.SH3]
sample.exe = 2
; Uses the SourceDisksNames.SH3 identification of 2.
[SourceDisksFiles.MIPS]
sample.exe = 2
; Uses the SourceDisksNames.MIPS identification of 2.
700 Series Color Mobile Computer User’s Manual
241
Chapter 7 — Programming
[DestinationDirs]
This describes the names and paths of the destination directories for the
application on the target device. Note Windows CE does not support directory
identifiers.
Required? Yes
S file_list_section:
0,subdir
String that identifies the destination directory. The following list shows
the string substitutions supported by Windows CE. These can be used
only for the beginning of the path. \
%CE1% \Program Files
%CE2% \Windows
%CE3% \My Documents
%CE4% \Windows\Startup
%CE5% \My Documents
%CE6% \Program Files\Accessories
%CE7% \Program Files\Communication
%CE8% \Program Files\Games
%CE9% \Program Files\Pocket Outlook
%CE10% \Program Files\Office
%CE11% \Windows\Start Menu\Programs
%CE12% \Windows\Start Menu\Programs\Accessories
%CE13% \Windows\Start Menu\Programs\Communications
%CE14% \Windows\Start Menu\Programs\Games
%CE15% \Windows\Fonts
%CE16% \Windows\Recent
%CE17% \Windows\Start Menu
%InstallDir%
Contains the path to the target directory selected during installation. It
is declared in the [CEStrings] section
%AppName%
Contains the application name defined in the [CEStrings] section.
Example
[DestinationDirs]
Files.Common = 0,%CE1%\My Subdir
Files.Shared = 0,%CE2%
242
; \Program Files\My Subdir
; \Windows
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
[CopyFiles]
This section, under the [DefaultInstall] section, describes the default files
to copy to the target device. Within the [DefaultInstall] section, files were
listed that must be defined elsewhere in the INF file. This section identifies that mapping and may contain flags.
Required? Yes
S copyfile_list_section:
destination_filename,[source_filename]
The source_filename parameter is optional if it is the same as destination_filename.
S copyfile_list_section:
flags
The numeric value that specifies an action to be done while copying files. The following table shows values supported by Windows CE.
Flag
Value
Description
COPYFLG_WARN_IF_SKIP
0x00000001 Warn user if skipping a file is attempted after error.
COPYFLG_NOSKIP
0x00000002 Do not allow a user to skip copying a file.
COPYFLG_NO_OVERWRITE
0x00000010 Do not overwrite files in destination directory.
COPYFLG_REPLACEONLY
0x00000400 Copy the source file to the destination directory only if the
file is already in the destination directory.
CE_COPYFLG_NO_DATE_DIALOG
0x20000000 Do not copy files if the target file is newer.
CE_COPYFLG_NODATECHECK
0x40000000 Ignore date while overwriting the target file.
CE_COPYFLG_SHARED
0x80000000 Create a reference when a shared DLL is counted.
Example
[DefaultInstall.SH3]
CopyFiles = Files.Common, Files.SH3
[DefaultInstall.MIPS]
CopyFiles = Files.Common, Files.MIPS
700 Series Color Mobile Computer User’s Manual
243
Chapter 7 — Programming
[AddReg]
This section, under the [DefaultInstall] section, is optional and describes
the keys and values that the .CAB file adds to the device registry. Within
the [DefaultInstall] section, a reference may have been made to this
section, such as “AddReg=RegSettings.All”. This section defines the
options for that setting.
Required? No
S add_registry_section: registry_root_string
String that specifies the registry root location. The following list shows
the values supported by Windows CE.
S HKCR
Same as HKEY_CLASSES_ROOT
S HKCU
Same as HKEY_CURRENT_USER
S HKLM
Same as HKEY_LOCAL_MACHINE
S add_registry_section: value_name
Registry value name. If empty, the “default” registry value name is used.
S add_registry_section: flags
Numeric value that specifies information about the registry key. The
following table shows the values that are supported by Window CE.
Flag
Value
Description
FLG_ADDREG_NOCLOBBER
0x00000002 If the registry key exists, do not overwrite it. Can be used
with any of the other flags in this table.
FLG_ADDREG_TYPE_SZ
0x00000000 REG_SZ registry data type.
FLG_ADDREG_TYPE_MULTI_SZ
0x00010000 REG_MULTI_SZ registry data type. Value field that follows
can be a list of strings separated by commas.
FLG_ADDREG_TYPE_BINARY
0x00000001 REG_BINARY registry data type. Value field that follows
must be a list of numeric values separated by commas, one
byte per field, and must not use the 0x hexadecimal prefix.
FLG_ADDREG_TYPE_DWORD
0x00010001 REG_DWORD data type. The noncompatible format in the
Win32 Setup .INF documentation is supported.
Example
AddReg = RegSettings.All
[RegSettings.All]
HKLM,%reg_path%,,0x00000000,alpha
HKLM,%reg_path%,test,0x00010001,3
HKLM,%reg_path%\new,another,0x00010001,6
244
;  = “alpha”
; Test = 3
; New\another = 6
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
[CEShortCuts]
This section, a Windows CE-specific section under the [DefaultInstall]
section, is optional and describes the shortcuts that the installation application creates on the device. Within the [DefaultInstall] section, a reference
may have been made to this section, such as “ShortCuts.All”. This section
defines the options for that setting.
Required? No
S shortcut_list_section:
shortcut_filename
String that identifies the shortcut name. It does not require the .LNK
extension.
S shortcut_list_section:
shortcut_type_flag
Numeric value. Zero or empty represents a shortcut to a file; any nonzero numeric value represents a shortcut to a folder.
S shortcut_list_section:
target_file_path
String value that specifies the destination location. Use the target file
name for a file, such as MyApp.exe, that must be defined in a file copy
list. For a path, use a file_list_section name defined in the [DestinationDirs] section, such as DefaultDestDir, or the %InstallDir% string.
S shortcut_list_section:
standard_destination_path
Optional string value. A standard %CEx% path or %InstallDir%. If no
value is specified, the shortcut_list_section name of the current section or
the DefaultDestDir value from the [DestinationDirs] section is used.
Example
CEShortcuts = Shortcuts.All
[Shortcuts.All]
Sample App,0,sample.exe
App,0,sample.exe,%InstallDir%
; Uses the path in DestinationDirs. Sample
; The path is explicitly specified.
Sample .INF File
[Version]
; Required section
Signature = “$Windows NT$”
Provider = “Intermec Technologies Corporation”
CESignature = “$Windows CE$”
;[CEDevice]
;ProcessorType =
[DefaultInstall]
; Required section
CopyFiles = Files.App, Files.Fonts, Files.BitMaps, Files.Intl,
Files.TelecomNcsCE, Files.Windows, Files.Import, Files.Export, Files.Work,
Files.Database, Files.WinCE AddReg = RegSettings.All ;CEShortcuts =
Shortcuts.All
[SourceDisksNames] ; Required section
1 = ,“App files” ,,c:\appsoft\...
2 = ,”Font files” ,,c:\WinNT\Fonts
3 = ,”CE Tools” ,,c:\windows ce tools\wce212\6110ie\mfc\lib\x86
[SourceDisksFiles] ; Required section
rpm.exe
= 1,C:\Appsoft\program\wce212\WCEX86Rel6110
wcestart.ini = 1
700 Series Color Mobile Computer User’s Manual
245
Chapter 7 — Programming
rpmce212.ini = 1
intermec.bmp = 1
rpmlogo.bmp = 1
rpmname.bmp = 1
import.bmp = 1
export.bmp = 1
clock.bmp = 1
printer.bmp = 1
filecopy.bmp = 1
readme.txt = 1
lang_eng.bin = 1
rpmdata.dbd = 1,database\wce1
tahoma.ttf = 2
mfcce212.dll = 3
olece212.dll = 3
olece211.dll = 1,c:\windows ce tools\wce211\NMSD61102.11\mfc\lib\x86
rdm45wce.dll = 1,c:\rptools\rdm45wce\4_50\lib\wce212\wcex86rel
picfmt.dll = 1,c:\rptools\picfmt\1_00\wce212\wcex86rel6110
fmtctrl.dll = 1,c:\rptools\fmtctrl\1_00\wce212\wcex86rel6110
ugrid.dll = 1,c:\rptools\ugrid\1_00\wce212\wcex86rel6110
simple.dll = 1,c:\rptools\pspbm0c\1_00\wce211\wcex86rel
psink.dll = 1,c:\rptools\psink\1_00\wce211\WCEX86RelMinDependency
pslpwce.dll =1,c:\rptools\pslpm0c\1_00\wce211\WCEX86RelMinDependency
npcpport.dll = 1,c:\rptools\cedk\212_03\installable drivers\printer\npcp
;dexcom.dll = 1,c:\rptools\psdxm0c\1_00\x86
ncsce.exe = 1,c:\rptools\ncsce\1_04
nrinet.dll = 1,c:\rptools\ncsce\1_04
[DestinationDirs] ; Required section
;Shortcuts.All = 0,%CE3% ; \Windows\Desktop
Files.App
= 0,%InstallDir%
Files.DataBase
= 0,%InstallDir%\DataBase
Files.BitMaps
= 0,%InstallDir%\Bitmaps
Files.Fonts
= 0,%InstallDir%\Fonts
Files.Intl
= 0,%InstallDir%\Intl
Files.TelecomNcsCE = 0,%InstallDir%\Telecom\NcsCE
Files.Windows
= 0,%InstallDir%\Windows
Files.Import
= 0,%InstallDir%\Import
Files.Export
= 0,%InstallDir%\Export
Files.Work
= 0,%InstallDir%\Work
Files.WinCE
= 0,\storage_card\wince
[CEStrings]
; Required section
AppName = Rp32
InstallDir = \storage_card\%AppName%
[Strings]
; Optional section
;[Shortcuts.All]
;Sample App,0,sample.exe
;Sample App,0,sample.exe,%InstallDir%
; Uses the path in DestinationDirs.
; The path is explicitly specified.
[Files.App]
rpm.exe,,,0
rpm.ini,rpmce212.ini,,0
mfcce212.dll,,,0
olece212.dll,,,0
olece211.dll,,,0
rdm45wce.dll,,,0
picfmt.dll,,,0
246
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
fmtctrl.dll,,,0
ugrid.dll,,,0
simple.dll,,,0
psink.dll,,,0
pslpwce.dll,,,0
npcpport.dll,,,0
;dexcom.dll,,,0
[Files.DataBase]
rpmdata.dbd,,,0
[Files.Fonts]
tahoma.ttf,,,0
[Files.BitMaps]
intermec.bmp,,,0
rpmlogo.bmp,,,0
rpmname.bmp,,,0
import.bmp,,,0
export.bmp,,,0
clock.bmp,,,0
printer.bmp,,,0
filecopy.bmp,,,0
[Files.Intl]
lang_eng.bin,,,0
[Files.TelecomNcsCE]
ncsce.exe,,,0
nrinet.dll,,,0
[Files.Windows]
readme.txt,,,0
[Files.Import]
readme.txt,,,0
[Files.Export]
readme.txt,,,0
[Files.Work]
readme.txt,,,0
[Files.WinCE]
wcestart.ini,,,0
[RegSettings.All]
HKLM,”SOFTWARE\Microsoft\Shell\AutoHide”,,0x00010001,1
; Autohide the taskbar HKLM,”SOFTWARE\Microsoft\Shell\OnTop”,,0x00010001,0
; Shell is not on top HKLM,”SOFTWARE\Microsoft\Clock”,SHOW_CLOCK,0x00010001,0
; Clock is not on taskbar
700 Series Color Mobile Computer User’s Manual
247
Chapter 7 — Programming
Using Installation Functions in SETUP.DLL
SETUP.DLL is an optional file that enables you to perform custom operations during installation and removal of your application. The following
list shows the functions that are exported by SETUP.DLL.
S Install_Init
Called before installation begins. Use this function to check the application version when reinstalling an application and to determine if a dependent application is present.
S Install_Exit
Called after installation is complete. Use this function to handle errors
that occur during application installation.
S Uninstall_Init
Called before the removal process begins. Use this function to close the
application, if the application is running.
S Uninstall_Exit
Called after the removal process is complete. Use this function to save
database information to a file and delete the database and to tell the user
where the user data files are stored and how to reinstall the application.
Note; Use [DefaultInstall] → CESelfRegister (page 240) in the .INF file
to point to SETUP.DLL.
After the CAB File Extraction
Cab files that need to cause a warm reset after cab extraction will need to
create the __RESETMEPLEASE__.TXT file in the “\Windows” directory.
The preferred method to create this file is within the DllMain portion of
the SETUP.DLL file. It looks like this:
BOOL APIENTRY DllMain( HANDLE hModule, DWORD ul_reason_for_call, LPVOID
lpReserved )
switch (ul_reason_for_call)
case DLL_PROCESS_ATTACH:
break;
case DLL_THREAD_ATTACH:
break;
case DLL_THREAD_DETACH:
break;
case DLL_PROCESS_DETACH:
if (bInstallSuccessful) {
HANDLE h;
h = CreateFile(L”\\Windows\\__resetmeplease__.txt”,
GENERIC_READ|GENERIC_WRITE, 0, NULL, CREATE_ALWAYS,
FILE_ATTRIBUTE_HIDDEN, NULL);
if (h != INVALID_HANDLE_VALUE)
CloseHandle(h);
break;
return TRUE;
248
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
The system software looks for the following directory structure and files on
the installed media card whether it be an SD card or CF card or embedded
flash file system. No other folders need exist.
\2577\autorun.exe
\2577\autorun.dat
\2577\autocab.exe
\2577\autocab.dat
\cabfiles\*.cab
Creating CAB Files with CAB Wizard
After you create the .INF file and the optional SETUP.DLL file, use the
CAB Wizard to create the .CAB file. The command-line syntax for the
CAB Wizard is as follows:
cabwiz.exe “inf_file” [/dest dest_directory] [/err error_file] [/cpu cpu_type
[cpu_type]]
A batch file, located in  directory, with the following commands, works well:
cd\“Windows CE Tools”\WCE211\”MS HPC Pro”\support\appinst\bin
cabwiz.exe c:\appsoft\\
cd \appsoft\
S “inf_file”
The SETUP.INF file path.
S dest_directory
The destination directory for the .CAB files. If no directory is specified,
the .CAB files are created in the “inf_file” directory.
S error_file
The file name for a log file that contains all warnings and errors that are
encountered when the .CAB files are compiled. If no file name is specified, errors are displayed in message boxes. If a file name is used, the
CAB Wizard runs without the user interface (UI); this is useful for automated builds.
S cpu_type
Creates a .CAB file for each specified microprocessor tag. A microprocessor tag is a label used in the Win32 SETUP.INF file to differentiate
between different microprocessor types. The /cpu parameter, followed by
multiple cpu_type values, must be the last qualifier in the command line.
Example
This example creates .CAB files for the SH3 and MIPS microprocessors,
assuming that the Win32 SETUP.INF file contains the SH3 and MIPS
tags:
cabwiz.exe “c:\myfile.inf” /err myfile.err /cpu sh3 mips
Note: CABWIZ.EXE, MAKECAB.EXE, and CABWIZ.DDF (Windows
CE files available on the Windows CE Toolkit) must be installed in the
same directory on the desktop computer. Call CABWIZ.EXE using its full
path for the CAB Wizard application to run correctly.
700 Series Color Mobile Computer User’s Manual
249
Chapter 7 — Programming
Troubleshooting the CAB Wizard
To identify and avoid problems that might occur when using the CAB
Wizard, follow these guidelines:
S Use %% for a percent sign (%) character when using this character in
an .INF file string, as specified in Win32 documentation. This will not
work under the [Strings] section.
S Do not use .INF or .CAB files created for Windows CE to install applications on Windows-based desktop platforms.
S Ensure the MAKECAB.EXE and CABWIZ.DDF files, included with
Windows CE, are in the same directory as CABWIZ.EXE.
S Use the full path to call CABWIZ.EXE.
S Do not create a .CAB file with the MAKECAB.EXE file included with
Windows CE. You must use CABWIZ.EXE, which uses MAKECAB.EXE to generate the .CAB files for Windows CE.
S Do not set the read-only attribute for .CAB files.
250
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
FTP Server
FTP support is provided through the FTP Server application
FTPDCE.EXE (MS Windows CE Versions) which is provided as part the
base system.
FTPDCE is the Internet File Transfer Protocol (FTP) server process. The
server can be invoked from an application or command line. Besides servicing FTP client requests the FTP Server also send a “network announcement” to notify prospective clients of server availability.
Synopsis
ftpdce [ options ]
Options
S -Aaddr
Sets the single target address to which to send the network announcement. Default is broadcast.
S -Bbyte
Sets the FTP data block size. Smaller sizes may be useful over slower
links. Default is 65536.
S -Cname
Sets the device name. Used by Intermec management software.
S -Fvalue
Disables the default Intermec account. A value of “0” disables the account. Default is “1”.
Note: Disabling the default account without providing a working access
control list on the server will result in a device that will not accept any
FTP connections.
S -Hsec
Sets the interval between network announcements in seconds.A value of
“0” turns the network announcement off. Default is 30 seconds.
S -Iip
Sets the preferred 6920 Communications Server (optional).
S -Llog
Sets the state of logging. Default is 0 (disabled).
S -Nsec
Specifies the number of seconds to wait before starting FTP server services.
S -Pport
Sets the UDP port on which the network announcement will be sent.
Default port is 52401.
S -Qport
Sets the port on which the FTP Server will listen for connections.
Default port is 21.
700 Series Color Mobile Computer User’s Manual
251
Chapter 7 — Programming
S -Rdir
Sets the FTP mount point to this directory. Default is the rootdirectory
of the drive from which the FTP Server program was executed.
S -Tscript
Sets the script name for the 6920 Communications Server to process.
S -Uurl
Sets the default URL for this device.
S -Z“parms”
Sets extended parameters to be included in the network announcement.
Configurable Parameters Via the Registry Editor
The following parameters receive default values during the installation of
the Intermec FTP Server components. A few of the parameters are visible
in the registry by default, but most must be created in order to modify the
default behavior of the FTP server.
BlockSize
Setting this parameter forces the Intermec FTP Server to transmit and receive Ethernet packets using the specified data block size. By default, the
FTP server transmits and receives data using a 64K data block size. Adjusting this value may be useful in certain wireless TCP/IP installations.
Key
HKLM\Software\Intermec\IFTP
Value Type
REG_DWORD - data block size, in bytes.
Valid Range
0x100-0x10000 (256-65536 decimal).
Default
65536
252
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
DeviceName
This parameter forces the Intermec FTP Server to include the specified
device name in the Intermec Device Network Announcement (IDNA).
Adjusting this value may be useful in assigning a symbolic name to this
device for asset tracking.
Key
HKLM\Software\Intermec\IFTP
Value Type
REG_SZ
Valid Range
None.
Default
None.
DeviceURL
This parameter forces the Intermec FTP Server to transmit the specified
URL in the IDNA. This can be used by Intermec management software
for asset management.
Key
HKLM\Software\Intermec\IFTP
Value Type
REG_SZ
Valid Range
None.
Default
None.
700 Series Color Mobile Computer User’s Manual
253
Chapter 7 — Programming
IDNATarget
This parameter forces the Intermec FTP Server to transmit the IDNA to a
specific destination instead of a general UDP broadcast. This parameter is
useful on networks that do not allow UDP broadcasts to be routed between subnets. The use of this parameter will restrict the reception of the
IDNA to the target destination only.
Key
HKLM\Software\Intermec\IFTP
Value Type
REG_SZ
Valid Range
None.
Default
None.
ManifestName
This parameter forces the Intermec FTP Server to transmit the specified
manifest name in the IDNA. This parameter is used by the Intermec 6920
Communications Server for communication transactions. See the 6920
Communications Server documentation for proper use of this parameter.
Key
HKLM\Software\Intermec\IFTP
Value Type
REG_SZ
Valid Range
None.
Default
iftp.ini
254
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
PauseAtStartup
This parameter forces the Intermec FTP Server to sleep for the specified
number of seconds before making the FTP service available on the device.
Key
HKLM\Software\Intermec\IFTP
Value Type
REG_DWORD - stored in seconds.
Valid Range
None.
Default
Root
This parameter forces the Intermec FTP Server to set the root of the FTP
mount point to the specified value. Note that this must map to an existing
directory or you will not be able to log into the FTP Server.
Key
HKLM\Software\Intermec\IFTP
Value Type
REG_SZ
Valid Range
None.
Default
700 Series Color Mobile Computer User’s Manual
255
Chapter 7 — Programming
Transferring Files Over TCP/IP Networks
The File Transfer Protocol (FTP) server transfers files over TCP/IP networks. The FTPDCE.EXE program is a version that does not display a
window, but can run in the background.
FTPDCE is the Internet File Transfer Protocol (FTP) server process. The
server can be invoked from an application or command line. Besides servicing FTP client requests, the FTP Server also sends a “network announcement” to notify prospective clients of server availability.
Remarks
The FTP Server currently supports the following FTP requests:
S CDUP
Changes to the parent directory of the current working directory.
S CWD
Changes working directory.
S DELE
Deletes a file.
S HELP
Gives help information.
S LIST (This FTP request is the same as the ls -lgA command).
Gives list files in a directory.
S MKD
Makes a directory.
S MODE (Always Uses Binary).
Specifies data transfer mode.
S NLST
Gives a name list of files in directory (this FTP request is the same as
the ls command).
S NOOP
Does nothing.
S PASS
Specifies a password.
S PWD
Prints the current working directory.
S QUIT
Terminates session.
S RETR
Retrieves a file.
S RMD
Removes a directory.
S RNFR
Specifies rename-from file name.
256
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
S RNTO
Specifies rename-to file name.
S STOR
Stores a file.
S SYST
Shows the operating system type of server system.
S TYPE (Binary transfers only.)
Specifies the data transfer type with the Type parameter.
S USER
Specifies user name.
S XCUP (Not Normally Used)
Changes the parent directory of the current working directory.
S XCWD (Not Normally Used)
Changes the current directory.
S XMKD (Not Normally Used)
Creates a directory.
S XPWD (Not Normally Used)
Prints the current working directory.
S XRMD (Not Normally Used)
Removes a directory.
S SITE
The following nonstandard or operating system (OS)-specific commands are supported by the SITE request. For Microsoft FTP clients,
you can send site commands by preceding the command with “quote”
such as “quote site status.”
S ATTRIB
Gets or sets the attributes of a given file. (SITE ATTRIB)
Usage:
QUOTE SITE ATTRIB [+R | -R] [+A | -A ] [+S | -S]
[+H | -H] [[path] filename]
Sets an attribute.
Clears an attribute.
Read-only file attribute.
Archive file attribute.
System file attribute.
H Hidden file attribute.
To retrieve the attributes of a file, only specify the file. The server response will be: 200-AD SHRCEIX filename
If the flag exists in its position shown above, it is set. Also, in addition
to the values defined above, there is also defined:
Compressed file attribute.
Encrypted file attribute.
INROM file attribute.
XIP file attribute (execute in ROM, not shadowed in RAM).
700 Series Color Mobile Computer User’s Manual
257
Chapter 7 — Programming
S BOOT
Reboots the server OS. This will cause the system on which the server is executing to reboot. The FTP Server will shut down cleanly before reboot. All client connections will be terminated. Cold boot is
default except for the PocketPC build in which the default is warm
boot.
(SITE BOOT)
Usage:
QUOTE SITE BOOT [WARM | COLD]
S COPY
Copies a file from one location to another. (SITE COPY)
Usage:
QUOTE SITE COPY [source] [destination]
Example
QUOTE SITE COPY ‘\Storage Card\one.dat’ ‘\Storage
Card\two.dat’
S EXIT
Exits the FTP Server. This command will shut down the FTP Server
thus terminating all client connections. (SITE EXIT)
Usage:
QUOTE SITE EXIT
S HELP
Gives site command help information. (SITE HELP)
Usage:
QUOTE SITE HELP [command]
S KILL
Terminates a running program. (SITE KILL)
Usage:
QUOTE SITE KILL [program | pid]
S LOG
Opens or closes the program log. (SITE LOG)
Usage:
QUOTE SITE LOG [open [filename]| close]
S PLIST
Lists the running processes (not supported on all platforms).
(SITE PLIST)
Usage:
QUOTE SITE PLIST
S RUN
Starts a program running. If the program to run has spaces in path or
filename, wrapping the name with single quotes is required.
Usage:
QUOTE SITE RUN [program]
Example
QUOTE SITE RUN ‘\Storage Card\app.exe’
258
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
S STATUS
Returns the current settings of the FTP Server. MAC, serial number,
model, IP address, network announcement information as well as OS
memory usage are returned. (SITE STATUS)
Usage:
QUOTE SITE STATUS
S TIMEOUT
Toggles idle timeout between 120 to 1200 seconds (2 to 20 minutes).
If this timer expires with no activity between the client and the server,
the client connection will be disconnected. If the optional seconds
argument is supplied, the server will set the connection timeout to
the number of seconds specified. Default is 120 seconds or 2 minutes.
(SITE TIMEOUT)
Usage:
QUOTE SITE TIMEOUT [seconds]
The remaining FTP requests specified in RFC 959 are recognized, but not
implemented.
The banner returned in the parenthetical portion of its greeting shows the
version number of the FTP Server as well as the MAC address, serial number and OS of the machine hosting the server.
The FTP Server supports browsing from the latest Netscape and Microsoft
web browsers. Drag-and-drop capability is available using this environment.
The FTPDCMDS subdirectory contains commands that can be used from
the web browser.
S Click EXITME.BIN to execute a SITE EXIT command.
S Click REBOOTME.BIN to execute SITE BOOT command.
S Use the GET command on these files to have the FTP Server execute
these commands.
S Security:
A customer configurable access control list may be installed on the
700 Series Computer. This list will allow customers to restrict access
via the FTP Server to the users they wish. This is in addition to the
default Intermec account which can be disabled using the -F0 option
at runtime.
The access control list is named FTPDCE.TXT and is placed in the
same directory on the 700 Series Computer as the FTPDCE.EXE
server. The FTP Server will encrypt this file to keep the information
safe from unauthorized users. This file is encrypted when the FTP
Server is started so a file that is placed onto the 700 Series Computer
after the FTP Server starts will require a restart of the FTP Server to
take effect.
The format of the FTPDCE.TXT is as follows:
FTPDCE:user1!passwd1user2!passwd2user3!passw
d3...
700 Series Color Mobile Computer User’s Manual
259
Chapter 7 — Programming
Note: The user accounts and passwords are case sensitive.
Once the access control list is encrypted on the 700 Series Computer, the
FTP Server will hide this file from users. Once an access control list has
been installed on the 700 Series Computer, a new one will not be accepted
by the FTP Server until the previous one is removed.
Encrypted access control lists are not portable between 700 Series Computers.
Stopping the FTP Server from Your Application
To allow application programmers the ability to programmatically shut
down the FTP Server, the FTP Server periodically tests to see if a named
event is signaled. The name for this event is “ITC_IFTP_STOP” (no
quotes).
For examples on how to use this event, consult the Microsoft Developer
Network Library at http://www.msdn.com. The MSDN Library is an essential resource for developers using Microsoft tools, products, and technologies. It contains a bounty of technical programming information, including sample code, documentation, technical articles, and reference guides.
Autostart FTP
This automatically starts the FTP Server (FTPDCE.EXE) when the 700
Series Computer is powered on. This is provided with the NDISTRAY
program, which displays the popup menu that currently allows you to load
and unload the network drivers. Tap the antenna icon in the System Tray
of the Today screen (a sample antenna icon is circled below) to get this popup menu.
260
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
The default is to start the FTP Server at boot time, unless the following
registry entry is defined and set to “0” which disables AutoFTP. “1” enables
the AutoFTP. The entry can be set from the NDISTRAY pop-up menu by
selecting either AutoFTP On or AutoFTP Off.
HKEY_LOCAL_MACHINE\Software\Intermec\Ndistray\StartupIFTP
These new entries are located below the selections to load the network
drivers. If the StartupIFTP registry key is not defined, the FTP Server is
loaded by default, to provide “out-of-the-box” capability for customers
who want to begin loading files to the 700 Series Computer without any
prior configuration.
Note: If a network driver is unloaded using the NDISTRAY popup menu,
and the FTP Server is running, the FTP Server is stopped.
On a resume, if AutoFTP is enabled and the FTP Server is running, it is
stopped and restarted. NDISTRAY uses a helper application named RESETIFTP to implement the restart on resume feature. To do an AutoFTP
Installation Check:
1 Ensure the FTP Server is running “out-of-the-box” the first time.
2 Tap Start → Today to access the Today screen, then tap the antenna
icon in the System Tray to bring up the NDISTRAY pop-up menu.
Select AutoFTP Off to disable AutoFTP. Do a warm boot and confirm
the FTP Server is not running.
3 Tap Start → Today to access the Today screen, then tap the antenna
icon in the System Tray to bring up the NDISTRAY pop-up menu.
Select AutoFTP On to enable AutoFTP, reboot and confirm it is
running.
4 Unload the network driver when the FTP Server is running and confirm
that it is not running any more.
5 Load the FTP Server, establish a connection, then suspend and resume.
The server should still be running, but the FTP connection to the client
should be dropped.
700 Series Color Mobile Computer User’s Manual
261
Chapter 7 — Programming
Full Screen
Pocket PC is a hardware specification created by Microsoft Corporation.
Devices that wish to carry the Pocket PC logo must meet the minimum
hardware requirements set in the Pocket PC specification. Manufacturers
are free to add extra hardware functionality.
Pocket PC 2002 devices also use a specialized version of the CE operating
system. This OS is built from Windows CE 3.0 but contains customizations, most notably the lack of a desktop and the addition of the Today
Screen.
To carry the Pocket PC logo, all devices must be tested at an Independent
Test Laboratory. The ITL testing is done based on Microsoft requirements.
The test lab then reports the findings back to Microsoft Corporation and
Intermec Technologies. If the 700 Series Computer passed all tests, Intermec is allowed to ship the device with the Pocket PC logo. Each time the
operating system is modified, Intermec must resubmit to ITL testing.
This means we cannot change the operating system much and still be a
Pocket PC device. For example, if we remove Word from the Start menu,
the device would fail ITL testing and we would not be able to ship devices
with the Pocket PC logo.
Although many customers want a Pocket PC device, some customers
would prefer that their users not have access to all of the Pocket PC features. Intermec cannot customize the operating system in any way but a custom application can:
S Delete items from the Start menu, and Programs folder. These items are
just shortcuts in the file system so the application is not really being
deleted. Cold booting the device will bring these items back so the application will need to be run on every cold boot.
S Use the RegFlushKey() API to save a copy of the registry to a storage
device. See the Recovery CD Help for more information on how to do
this. Saving a copy of the registry will allow most system settings to be
restored in a cold boot situation.
S Use the SHFullScreen() API in conjunction with other APIs to make the
application take up the entire display and prevent the start menu from
being available.
S Remap keys and disable keys on the keypad.
S Create a custom SIP.
S Make changes to the registry to configure the device.
262
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
Should you want your 700 Series Computer to display a full screen, keep
in mind that your computer is Pocket-PC certified by Microsoft Corporation. Check out resources on programming for the Pocket PC, using the
following links. These instructions give full instructions on how to display
full screen.
S Instructions on how to create a full screen application for eVC++ applications using an SHFullScreen() API:
http://support.microsoft.com/support/kb/articles/Q266/2/44.ASP
S Instructions on how to create a full screen application for eVB applications also using the SHFullScreen() API:
http://support.microsoft.com/support/kb/articles/Q265/4/51.ASP
700 Series Color Mobile Computer User’s Manual
263
Chapter 7 — Programming
Kernel I/O Controls
This describes the KernelIoControl() functions available to application
programmers. Most C++ applications will need to prototype the function
as the following to avoid link and compile errors.
extern “C” BOOL KernelIoControl(DWORD dwIoControlCode, LPVOID lpInBuf, DWORD
nInBufSize, LPVOID lpOutBuf, DWORD nOutBufSize, LPDWORD lpBytesReturned);
IOCTL_HAL_GET_DEVICE_INFO
This IOCTL returns either the platform type or the OEMPLATFORM
name based on an input value.
Syntax
BOOL KernelIoControl( IOCTL_HAL_GET_DEVICE_INFO, LPVOID
lpInBuf, DWORD nInBufSize, LPVOID lpOutBuf, DWORD
nOutBufSize, LPDWORD lpBytesReturned );
Parameters
lpInBuf
Points to a DWORD containing either the
SPI_GETPLATFORMTYPE or SPI_GETOEMINFO
value.
lpInBufSize
Must be set to sizeof(DWORD).
lpOutBuf
Must point to a buffer large enough to hold the return
data of the function. If SPI_GETPLATFORMTYPE is
specified in lpInBuf, then the “PocketPC\0” Unicode
string is returned. If SPI_GETOEMINFO is specified in
lpInBuf, then the “Intermec 700\0” Unicode string is
returned.
nOutBufSize
The size of lpOutBuf in bytes. Must be large enough to
hold the string returned.
lpBytesReturned The actual number of bytes returned by the function for
the data requested.
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the extended error value.
264
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
IOCTL_HAL_ITC_READ_PARM
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_ITC_READ_PARM,LPVOID
lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
lpInBuf
Points to this structure. See “ID Field Values” below.
struct PARMS {
BYTE id;
BYTE ClassId;
};
nInBufSize
Must be set to the size of the PARMS structure.
lpOutBuf
Must point to a buffer large enough to hold the return
data of the function. If this field is set to NULL and
nOutBufSize is set to zero when the function is called the
function will return the number bytes required by the
buffer.
nOutBufSize
The size of lpOutBuf in bytes.
lpBytesReturned The number of bytes returned by the function for the
data requested.
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the error value. Either
ERROR_INVALID_PARAMETER or
ERROR_INSUFFICIENT_BUFFER may be returned when this function
is used to get the error.
ID Field Values
The id field of the PARMS structure may be one of the following values:
S ITC_NVPARM_ETHERNET_ID
This IOCTL returns the Ethernet 802.11 MAC Address. Six bytes are
returned in the buffer pointed to by the lpOutBuffer parameter.
S ITC_NVPARM_SERIAL_NUM
This IOCTL returns the serial number of the device in BCD format.
Six bytes are returned in the buffer pointed to by the lpOutBuffer parameter.
S ITC_NVPARM_MANF_DATE
This IOCTL returns the device date of manufacture in the
BCD YYYY/MM/DD format. Four bytes are returned in the buffer
pointed to by the lpOutBuffer parameter.
700 Series Color Mobile Computer User’s Manual
265
Chapter 7 — Programming
S ITC_NVPARM_SERVICE_DATE
This IOCTL returns the device’ s date of last service in BCD YYYY/
MM/DD format. Four bytes are returned in the buffer pointed to by
the lpOutBuffer parameter.
S ITC_NVPARM_DISPLAY_TYPE
This IOCTL returns the device’ s display type. One byte is returned in
the buffer pointed to by the lpOutBuffer parameter.
S ITC_NVPARM_EDG_IP
This IOCTL returns the device Ethernet debug IP address. Four bytes
are returned in the buffer pointed to by the lpOutBuffer parameter.
S ITC_NVPARM_EDBG_SUBNET
This IOCTL returns the device Ethernet debug subnet mask. Four bytes are returned in the buffer pointed to by the lpOutBuffer parameter.
S ITC_NVPARM_ECN
This IOCTL returns ECNs applied to the device in a bit array format.
Four bytes are returned in the buffer pointed to by the lpOutBuffer parameter.
S ITC_NVPARM_CONTRAST
This IOCTL returns the device default contrast setting. Two bytes are
returned in the buffer pointed to by the lpOutBuffer parameter.
S ITC_NVPARM_MCODE
This IOCTL returns the manufacturing configuration code for the device. Sixteen bytes are returned in the buffer pointed to by the lpOutBuffer parameter.
S ITC_NVPARM_VERSION_NUMBER
This IOCTL returns the firmware version for various system components. These values for the ClassId field of the PARMS structure are allowed when ITC_NVPARM_VERSION_NUMBER is used in the id
field:
S VN_CLASS_KBD
Returns a five-byte string, including null terminator, that contains an
ASCII value which represents the keyboard microprocessor version in
the system. The format of the string is x.xx with a terminating null
character.
S VN_CLASS_ASIC
Returns a five-byte string, including null terminator, that contains an
ASCII value which represents the version of the FPGA firmware in
the system. The format of the string is x.xx with a terminating null
character.
S VN_CLASS_BOOTSTRAP
Returns a five-byte string, including null terminator, that contains an
ASCII value which represents the version of the Bootstrap Loader
firmware in the system. The format of the string is x.xx with a terminating null character.
266
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
S ITC_NVPARM_INTERMEC_SOFTWARE_CONTENT
This IOCTL reads the manufacturing flag bits from the non-volatile
data store that dictates certain software parameters. A BOOLEAN
DWORD is returned in the buffer pointed to by lpOutBuffer that indicates if Intermec Content is enabled in the XIP regions. TRUE indicates
that it is enabled. FALSE indicates that it is not enabled.
S ITC_NVPARM_ANTENNA_DIVERSITY
This IOCTL reads the state of the antenna diversity flag. A BOOLEAN
DWORD is returned in the buffer pointed to by lpOutBuffer that indicates if there is a diversity antenna installed. TRUE indicates that it is
installed. FALSE indicates that it is not installed.
S ITC_NVPARM_WAN_RI
This IOCTL reads the state of the WAN ring indicator flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer that
indicates the polarity of the WAN RI signal. TRUE indicates active
high. FALSE indicates active low.
S ITC_NVPARM_RTC_RESTORE
This IOCTL reads the state of the real-time clock restore flag. A
BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the RTC will be restored upon a cold boot.
FALSE indicates that the RTC will not be restored.
S ITC_NVPARM_INTERMEC_DATACOLLECTION_SW
This IOCTL reads the state of the data collection software enabled flag.
A BOOLEAN DWORD is returned in the buffer pointer to by lpOutBuffer that indicates the data collection software is to be installed at boot
time. FALSE indicates the data collection software should not be
installed.
S ITC_NVPARM_INTERMEC_DATACOLLECTION_HW
This IOCTL reads the data collection hardware flags. A BYTE is returned in the buffer pointer to by lpOutBuffer that indicates the type of
data collection hardware installed. The maximum possible value returned is ITC_DEVID_SCANHW_MAX.
S ITC_DEVID_SCANHW_NONE
No scanner hardware is installed.
S ITC_DEVID_OEM2D_IMAGER
OEM 2D imager is installed.
S ITC_DEVID_INTERMEC2D_IMAGER
Intermec 2D imager is installed.
S ITC_DEVID_SE900_LASER
SE900 laser is installed.
S ITC_DEVID_SE900HS_LASER
SE900HS laser is installed.
The high bit indicates whether the S6 scanning engine is installed. The
bit mask for this is ITC_DEVID_S6ENGINE_MASK. A non-zero value indicates that the S6 scanning engine is installed.
700 Series Color Mobile Computer User’s Manual
267
Chapter 7 — Programming
S ITC_NVPARM_WAN_INSTALLED
This IOCTL reads the state of the WAN radio installed flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer.
TRUE indicates that the WAN radio is installed. FALSE indicates that
no WAN radio is installed.
S ITC_NVPARM_WAN_FREQUENCY
This IOCTL reads the state of the WAN radio frequency flag. A
BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the WAN radio frequency is United States.
FALSE indicates that the WAN radio frequency is European.
S ITC_NVPARM_WAN_RADIOTYPE
This IOCTL reads the WAN radio ID installed by manufacturing. A
BYTE is returned in the buffer pointer to by lpOutBuffer which indicates the type of WAN radio hardware installed. The maximum possible
value returned is ITC_DEVID_WANRADIO_MAX. The current definitions are:
S ITC_DEVID_WANRADIO_NONE
No WAN radio installed.
S ITC_DEVID_WANRADIO_SIERRA_SB555
CDMA Sierra Wireless radio.
S ITC_DEVID_WANRADIO_XIRCOM_GEM3503
GSM/GPRS Intel (Xircom) radio.
S ITC_DEVID_WANRADIO_SIEMENS_MC45
GSM/GPRS Siemens radio.
S ITC_NVPARM_80211_INSTALLED
This IOCTL reads the state of the 802.11b radio installed flag. A
BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the 802.11b radio is installed. FALSE indicates
that no 802.11b radio is installed.
S ITC_NVPARM_80211_RADIOTYPE
This IOCTL reads the 802.11b radio ID installed by manufacturing. A
BYTE is returned in the buffer pointer to by lpOutBuffer that indicates
the type of 802.11b radio hardware installed. The maximum possible
value returned is ITC_DEVID_80211RADIO_MAX. The current definitions are:
S ITC_DEVID_80211RADIO_NONE
No 802.11b radio installed.
S ITC_DEVID_80211RADIO_INTEL_2011B
Intel 2011B radio installed.
S ITC_NVPARM_BLUETOOTH_INSTALLED
This IOCTL reads the state of the Bluetooth radio installed flag. A
BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the Bluetooth radio is installed. FALSE indicates that no Bluetooth radio is installed.
268
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
S ITC_NVPARM_SERIAL2_INSTALLED
This IOCTL reads the state of the serial 2 (COM2) device installed
flag. A BOOLEAN DWORD is returned in the buffer pointed to by
lpOutBuffer. TRUE indicates that the serial 2 device is installed. FALSE
indicates that no serial 2 device is installed.
S ITC_NVPARM_VIBRATE_INSTALLED
This IOCTL reads the state of the vibrate device installed flag. A
BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the vibrate device is installed. FALSE indicates
that no vibrate device is installed.
S ITC_NVPARM_LAN9000_INSTALLED
This IOCTL reads the state of the Ethernet device installed flag. A
BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the Ethernet device is installed. FALSE indicates that no Ethernet device is installed.
S ITC_NVPARM_SIM_PROTECT_HW_INSTALLED
This IOCTL reads the state of the SIM card protection hardware
installed flag. A BOOLEAN DWORD is returned in the buffer pointed
to by lpOutBuffer. TRUE indicates that the SIM card protection hardware is installed. FALSE indicates that no SIM card protection hardware
is installed.
S ITC_NVPARM_SIM_PROTECT_SW_INSTALLED
This IOCTL reads the state of the SIM card protection software
installed flag. A BOOLEAN DWORD is returned in the buffer pointed
to by lpOutBuffer. TRUE indicates that the SIM card protection software is installed. FALSE indicates that no SIM card protection software
is installed.
700 Series Color Mobile Computer User’s Manual
269
Chapter 7 — Programming
IOCTL_HAL_ITC_WRITE_SYSPARM
Describes and enables the registry save location.
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_ITC_WRITE_SYSPARM,LPVOID
lpInBuf,DWORD nInBufSize, LPVOID lpOutBuf, DWORD
nOutBufSize, LPDWORD lpBytesReturned );
Parameters
lpInBuf
A single byte that may be one of the id values.
See “ID Field Values” below.
nInBufSize
Must be set to the size of the lpInBuf in bytes.
lpOutBuf
Must point to a buffer large enough to hold the data to
be written to the non-volatile data store.
nOutBufSize
The size of lpOutBuf in bytes.
lpBytesReturned The number of bytes returned by the function.
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the error value. Either
ERROR_INVALID_PARAMETER or
ERROR_INSUFFICIENT_BUFFER may be returned when this function
is used to get the error.
ID Field Values
The id field of lpInBuf may be one of the following values:
S ITC_REGISTRY_LOCATION
This IOCTL sets the default location for where to write the registry
when RegFlushKey() is called by an application. The registry may be
saved to Flash, a CompactFlash storage card or a SecureDigital storage
card. lpOutBuf must point to a buffer that contains a byte value of “1”
for the CompactFlash card or “2” for the SecureDigital card to specify
the location.
S ITC_REGISTRY_SAVE_ENABLE
This function enables or disables the save registry to non-volatile media
feature of the RegFlushKey() function. lpOutBuf must be set to zero
(FALSE) if the feature is to be disabled or one (TRUE) if the feature is
to be enabled.
S ITC_ DOCK_SWITCH
This IOCTL sets a position of the dock switch. The dock switch may
be set to either “modem” or “serial” positions. lpOutBuf must point to a
buffer that contains a byte value of either DOCK_MODEM or
DOCK_SERIAL as defined in OEMIOCTL.H; the value specifies the
position the switch is to be set.
270
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
S ITC_ WAKEUP_MASK
This IOCTL sets a bit mask that represents the mask for the five programmable wakeup keys. The I/O key is not a programmable wakeup
key. By default it is always the system resume key and all other keys are
set to disable key wakeup. A zero in a bit position masks the wakeup for
that key. A one in a bit position enables wakeup for that key. lpOutBuf
must point to a buffer that contains a byte value of a wakeup mask consisting of the OR’ ed constants as defined in OEMIOCTL.H. Only the
following keys are programmable as wakeup events.
#define
#define
#define
#define
#define
SCANNER_TRIGGER 1
SCANNER_LEFT
SCANNER_RIGHT 4
GOLD_A1
GOLD_A2
0x10
S ITC_AMBIENT_KEYBOARD
This IOCTL sets the threshold for the keyboard ambient sensor. This
can be a value from 0 (always off ) to 255 (always on). lpOutBuf must
point to a buffer that contains a byte value of the desired setting.
S ITC_AMBIENT_FRONTLIGHT
This IOCTL sets the threshold for the frontlight ambient sensor. This
can be a value from 0 (always off ) to 255. lpOutBuf must point to a
buffer that contains a byte value of the desired setting.
700 Series Color Mobile Computer User’s Manual
271
Chapter 7 — Programming
IOCTL_HAL_GET_DEVICEID
This IOCTL returns the device ID. There are two types of device IDs supported, which are differentiated based on the size of the output buffer. The
UUID is returned if the buffer size is set to sizeof(UNIQUE_DEVICEID),
otherwise the oldstyle device ID is returned.
Usage
#include “pkfuncs.h”
#include “deviceid.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_GET_DEVICEID,LPVOID
lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
lpInBuf
Should be set to NULL. STRICT_ID settings are not
supported.
lpInBufSize
Should be set to zero.
lpOutBuf
Must point to a UNIQUE_DEVICEID structure as
defined by DEVICEID.H if the UUID is to be returned.
nOutBufSize
The size of the UNIQUE_DEVICEID in bytes if the
UUID is to be returned. A DEVICE_ID as defined by
PKFUNCS.H is returned if the size in bytes is greater
than or equal to sizeof(DEVICE_ID).
lpBytesReturned The number of bytes returned by the function.
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the extended error value.
272
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
IOCTL_HAL_GET_OAL_VERINFO
Returns the HAL version information of the Pocket PC image.
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_GET_OAL_VERINFO,LPVOID
lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
lpInBuf
Should be set to NULL.
lpInBufSize
Should be set to zero.
lpOutBuf
Must point to a VERSIONINFO structure as defined by
OEMIOCTL.H. The fields should have these values:
sizeof (tagOemVerInfo);
S cboemverinfo
S verinfover
S sig;
“ITC\0”
S id;
‘ N’
S tgtcustomer
“”
tgtplat
SeaRay
S tgtplatversion
Current build version number
S tgtcputype[8];
“Intel\0”
S tgtcpu
“PXA250\0”;
S tgtcoreversion
“”
S date
Build time
S time
Build date
nOutBufSize
The size of VERSIONINFO in bytes.
lpBytesReturned Returns sizeof(PVERSIONINFO).
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the extended error value.
700 Series Color Mobile Computer User’s Manual
273
Chapter 7 — Programming
IOCTL_HAL_GET_BOOTLOADER_VERINFO
Returns the HAL version information of the Pocket PC image.
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_GET_OAL_VERINFO,LPVOID
lpInBuf, DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
lpInBuf
Should be set to NULL.
lpInBufSize
Should be set to zero.
lpOutBuf
Must point to a VERSIONINFO structure as defined by
OEMIOCTL.H. The fields should have these values:
Sizeof (tagOemVerInfo);
S cboemverinfo
S verinfover
S sig;
“ITC\0”
S id;
‘ B’
S tgtcustomer
“”
tgtplat
SeaRay
S tgtplatversion Current build version number of
the bootstrap loader
S tgtcputype[8]; “Intel\0”;
S tgtcpu
“PXA250\0”
S tgtcoreversion “”
S date
Build time
S time
Build date
nOutBufSize
The size of VERSIONINFO in bytes.
lpBytesReturned The number of bytes returned to lpOutBuf.
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the extended error value.
274
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
IOCTL_HAL_WARMBOOT
Causes the system to perform a warm-boot. The object store is retained.
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_WARMBOOT,LPVOID
lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
lpInBuf
Should be set to NULL.
lpInBufSize
Should be set to zero.
lpOutBuf
Should be NULL.
nOutBufSize Should be zero.
Return Values
None.
IOCTL_HAL_COLDBOOT
Causes the system to perform a cold-boot. The object store is cleared.
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_COLDBOOT,LPVOID
lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
lpInBuf
Should be set to NULL.
lpInBufSize
Should be set to zero.
lpOutBuf
Should be NULL.
nOutBufSize Should be zero.
Return Values
None.
700 Series Color Mobile Computer User’s Manual
275
Chapter 7 — Programming
IOCTL_HAL_GET_RESET_INFO
This IOCTL code allows software to check the type of the most recent reset.
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_GET_RESET_INFO,LPVOID
lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
lpInBuf
Should be set to NULL.
lpInBufSize
Should be set to zero.
lpOutBuf
Must point to a HAL_RESET_INFO structure:
typedef struct {
DWORD ResetReason;
DWORD ObjectStoreState;
} HAL_RESET_INFO, * PHAL_RESET_INFO;
// most recent reset type
// state of object store
// Reset reason types
#define HAL_RESET_TYPE_UNKNOWN
#define HAL_RESET_REASON_HARDWARE
#define HAL_RESET_REASON_SOFTWARE
#define HAL_RESET_REASON_WATCHDOG
#define HAL_RESET_BATT_FAULT
#define HAL_RESET_VDD_FAULT
16
// Object store state flags
#define HAL_OBJECT_STORE_STATE_UNKNOWN
#define HAL_OBJECT_STORE_STATE_CLEAR
nOutBufSize
// cold
// suspend
// power fail
// warm boot
The size of HAL_RESET_INFO in bytes.
lpBytesReturned The number of bytes returned by the function.
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the extended error value.
276
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
IOCTL_HAL_GET_BOOT_DEVICE
This IOCTL code allows software to check which device CE booted from.
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_GET_BOOT_DEVICE,LPVOID
lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
lpInBuf
Should be set to NULL.
lpInBufSize
Should be set to zero.
lpOutBuf
Must point to a buffer large enough to hold a DWORD
(4 bytes) that contains the boot device. The following
boot devices are supported:
#define
#define
#define
#define
#define
#define
#define
HAL_BOOT_DEVICE_UNKNOWN
HAL_BOOT_DEVICE_ROM_XIP
HAL_BOOT_DEVICE_ROM
HAL_BOOT_DEVICE_PCMCIA_ATA
HAL_BOOT_DEVICE_PCMCIA_LINEAR
HAL_BOOT_DEVICE_IDE_ATA
HAL_BOOT_DEVICE_IDE_ATAPI
nOutBufSize
The size of lpOutBuf in bytes (4).
lpBytesReturned The number of bytes returned by the function.
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the extended error value.
700 Series Color Mobile Computer User’s Manual
277
Chapter 7 — Programming
IOCTL_HAL_REBOOT
Causes the system to perform a warm-boot. The object store is retained.
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_HAL_REBOOT,LPVOID lpInBuf,DWORD
nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD
lpBytesReturned );
Parameters
lpInBuf
Should be set to NULL.
lpInBufSize
Should be set to zero.
lpOutBuf
Should be NULL.
nOutBufSize
Should be zero.
Return Values
None.
278
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
IOCTL_PROCESSOR_INFORMATION
Returns processor information.
Usage
#include “pkfuncs.h”
Syntax
BOOL KernelIoControl( IOCTL_PROCESSOR_INFORMATION,LPVOID
lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
Parameters:
lpInBuf
Should be set to NULL.
lpInBufSize
Should be set to zero.
lpOutBuf
Should be a pointer to the PROCESSOR_INFO
structure. The PROCESSOR_INFO structure stores
information that describes the CPU more descriptively.
typedef
WORD
WCHAR
WORD
WCHAR
WORD
WCAHR
WCHAR
DWORD
DWORD
__PROCESSOR_INFO {
wVersion;
szProcessorCore[40];
wCoreRevision;
szProcessorName[40];
wProcessorRevision;
szCatalogNumber[100];
szVendor[100];
dwInstructionSet;
dwClockSpeed;
nOutBufSize
//
//
//
//
//
//
//
//
//
Set to value 1
“ARM\0”
“PXA250\0”
“Intel Corporation\0”
400
Should be set to sizeof(PROCESSOR_INFO) in bytes.
lpBytesReturned Returns sizeof(PROCESSOR_INFO);
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the extended error value.
700 Series Color Mobile Computer User’s Manual
279
Chapter 7 — Programming
IOCTL_GET_CPU_ID
Returns Xscale processor ID.
Usage
#include “oemioctl.h”
Syntax
BOOL KernelIoControl( IOCTL_GET_CPU_ID,LPVOID lpInBuf, DWORD
nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD
lpBytesReturned );
Parameters
lpInBuf
Should point to a CPUIdInfo structure defined in
OEMIOCTL.H.
lpInBufSize
Should be sizeof(CPUIdInfo).
lpOutBuf
Should be NULL.
nOutBufSize
Should be set to 0.
lpBytesReturned Returns sizeof(PROCESSOR_INFO);
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the extended error value.
Reboot Functions
There are several methods, via Kernel I/O Control functions, that an application program can use to force the 700 Series Computer to reboot.
IOCTL_HAL_REBOOT
IOCTL_HAL_REBOOT performs a warm-boot. See page 278.
IOCTL_HAL_COLDBOOT
Invoking the KernelIOControl function with
IOCTL_HAL_COLDBOOT forces a cold reboot. This resets the 700
Series Computer and reloads Windows CE as if a power-up had been
performed. The contents of the Windows CE RAM-based object store are
discarded. See page 275.
IOCTL_HAL_WARMBOOT
This function is supported on the 700 Series Computers. It performs a
warm boot of the system, preserving the object store. See page 275.
280
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
Remapping the Keypad
Note; Use caution when remapping the keypad. Improper remapping may
render the keypad unusable. Data within the 700 Series Computer could
also be lost, should any problems occur.
Applications have the ability to remap keys on the 700 Color Keypad. This
will allow applications to enable keys that would otherwise not be available, such as the [F1] function key. Also, to disable keys that should not be
available, such as the alpha key because no alpha entry is required. Care
should be exercised when attempting to remap the keypad because improper remapping may cause the keypad to become unusable. This can be
corrected by cold booting the device which will cause the default keymap
to be loaded again.
Note that remapping the keys in this way affects the key mapping for the
entire system, not just for the application that does the remapping.
There are three “planes” supported for the 740 Keypad. Keys that are to be
used in more than one shift plane must be described in each plane.
Unshifted Plane
The unshifted plane contains values from the keypad when not pressed
with other keys, such as the following:
S [1]
S [5]
S [9]
Gold Plane
The gold plane contains values from the keypad when a key is simultaneously pressed with the [Gold] key, such as the following:
S [Gold] + [1]
Send
S [Gold] + [5]
A3
S [Gold] + [9]
PageDown
Alpha Plane
The alpha plane contains values from the keypad when the keypad has
been placed in alpha mode by pressing the blue alpha key, such as the following:
S [Alpha] + [1]
Caps
S [Alpha] + [5]
JKL
S [Alpha] + [9]
WXYZ
700 Series Color Mobile Computer User’s Manual
281
Chapter 7 — Programming
Key Values
Key values for each plane are stored in the registry. All units ship with a
default key mapping already loaded in the registry. Applications that wish
to change the default mapping need to read the appropriate key from the
registry into an array of Words, modify the values required and then write
the updated values back into the registry. The registry access can be done
with standard Microsoft API calls, such as RegOpenKeyEx(), RegQueryValueEx(), and RegSetValueEx().
S The unshifted plane mapping can be found in the registry at:
HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\KEYBD\Vkey
S The gold plane mapping can be found in the registry at:
HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\KEYBD\VkeyGold
S The alpha plane mapping can be found in the registry at:
HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\KEYBD\VkeyAlpha
How Key Values Are Stored in Registry
To know which fields to update in the registry, you must know what Scan
Codes are assigned to each physical key (see the table below). The Scan
Code is used at the lowest level of the system to let the keypad driver know
which physical key has been pressed. The keypad driver takes that scan
code and looks it up in a table (a copy of the one stored in the registry) to
determine which values to pass on to the operating system.
Each registry key is just an array that describes to the keypad driver what
value needs to be passed for each physical key. The key values are indexed
by the scan code, this is a zero-based index. For example in the unshifted
plane, the [4] key has a scan code of 0x06. This means that the seventh
word under the “Vkey” registry key will have the value for the [4] key.
Taking a sample of the “Vkey” registry key shows the following values:
00,00,0B,05,02,03,C1,07,04,03,BE,00,34,00,00,00,. . .
The value is 34,00. The values are in reverse byte order because that is the
way the processor handles data. When writing an application, nothing
needs to be done to swap the bytes, as this will happen automatically when
the data is read into a byte value. This is something you just need to be
aware of this when looking at the registry. Knowing this, we can see that
the value that the keypad driver will pass to the system is a hex 34. Looking that up on an UNICODE character chart, we see that it maps to a “4”.
If you wanted the key, labeled “4”, to output the letter “A” instead, you
would need to change the seventh word to “41” (the hexadecimal representation of “A” from the UNICODE chart), then put the key back into the
registry.
Note: Do not remap scan codes 0x01, 0x41, 0x42, 0x43, 0x44. Remapping these scan codes could render your 700 Series Computer unusable
until a cold-boot is performed.
If you wish to disable a certain key, remap its scan code to 0x00.
282
700 Series Color Mobile Computer User’s Manual
Chapter 7 — Programming
Change Notification
Just changing the registry keys will not immediately change the key
mappings. To notify the keypad driver that the registry has been updated,
signal the “ITC_KEYBOARD_CHANGE” named event using the
CreateEvent() API.
Advanced Keypad Remapping
It is also possible to map multiple key presses to one button and to map
named system events to a button. The multiple key press option could be
useful to cut down on the number of keys needed to press in a given situation or to remap which key behaves like the action key. Mapping events to
a button could be useful to change which buttons will fire the scanner,
control volume, and allow for suspending and resuming the device. If you
need help performing one of these advanced topics please contact Intermec
Technical Support.
Scan Codes
At the lowest driver level, the 740 Keypad identifies keys as scan codes.
These scan codes are sent via the keypad microcontroller, and cannot be
changed without modifying the keypad firmware.
Key/Meaning
Reserved
I/O Button
Scanner Trigger
Scanner Left
Scanner Right
None
Left Arrow
None
Backspace
Gold Key
None
ESC
Down Arrow
Alpha Key
None
Up Arrow
Right Arrow
None
700 Series Color Mobile Computer User’s Manual
Scancode
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
0x14
0x15
0x16
0x17
0x18
0x19
283
Chapter 7 — Programming
Key/Meaning
Action Key
ENTER
None
Charge Detect
Scancode
0x1A
0x1B
0x1C
0x1D
0x1E
0x1F-0x40
0x41
LCD Frontlight
Ambient Light
Threshold Crossed
0x42
0x42
0x42
Headset Detected
0x43
Keypad Backlight
Ambient Light
Threshold Crossed
0x44
0x44
0x44
Sample View of Registry Keys
The following is a sample view of the current default key mapping. See the
registry on your device for the latest key mappings.
[HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\KEYBD]
”ResumeMask”=dword:7
”Vkey”=hex: 00,00,0B,05,02,03,C1,07,04,03,BE,00,34,00,00,00,\
25,00,00,00,08,00,03,02,00,00,1B,00,28,00,31,00,\
37,00,01,02,00,00,26,00,27,00,32,00,38,00,30,00,\
35,00,00,00,01,03,33,00,39,00,0D,00,36,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,07,05,01,05,03,05,02,05
”VkeyGold”=hex: 00,00,0B,05,02,03,C1,07,04,03,BE,00,34,00,00,00,\
09,01,00,00,BF,00,03,02,00,00,BD,00,75,00,72,00,\
21,00,01,02,00,00,76,00,09,00,73,00,38,01,5B,00,\
35,00,00,00,BB,01,09,05,22,00,32,01,36,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,07,05,01,05,03,05,02,05
”VkeyAlpha”=hex: 00,00,0B,05,02,03,C1,07,04,03,BE,00,47,00,00,00,\
25,00,00,00,08,00,03,02,00,00,1B,00,28,00,02,02,\
50,00,01,02,00,00,26,00,27,00,41,00,54,00,20,00,\
4A,00,00,00,01,03,44,00,57,00,0D,00,4D,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\
00,00,07,05,01,05,03,05,02,05
284
700 Series Color Mobile Computer User’s Manual
A
Control Panel Applets
This appendix contains information about the Data Collection, SNMP,
and User Information Control Panel applets that may be on your 700 Series Color Mobile Computer.
SNMP and Data Collection settings that can appear under Settings are
dependent on what hardware configuration is done for each 700 Series
Computer at the time of shipment. These settings will currently only appear if a scanner or an imager option is present.
Likewise, other control panel applets that are specifically related to the
802.11b radio module will appear when a 802.11b radio module is
installed in a 700 Series Computer. Control panel applets that are specific
for Wireless Printing, CDMA/1xRTT, and GSM/GPRS radio modules
will only appear when each respective hardware configuration is done on
the 700 Series Computer. See Chapter 4, “Network Support,” for more information about the radio modules or the wireless printing.
700 Series Color Mobile Computer User’s Manual
285
Appendix A — Control Panel Applets
Configuration Parameters
A configuration parameter changes the way the 700 Series Color (700C)
Mobile Computer operates, such as configuring a parameter to have the
700 Series Computer emit a very loud beep in a noisy environment. Use
any of the following methods to execute configuration parameters:
S Change Data Collection and SNMP parameters via control panel applets later in this appendix.
S Access the 700 Series Computer via the Unit Manager through a web
browser on your desktop PC via the SRDEVMGMT.CAB file. To use
the Unit Manager, install this CAB file from the 700 Color Software
Tools CD-ROM. Unit Manager applications are available on the 700
Series Color Unit Manager CD-ROM. For more information, consult
your Intermec sales representative.
S Send parameters from an SNMP management station. See “SNMP Configuration” starting on page 123.
S Scan EasySet bar codes. You can use the EasySet bar code creation software from Intermec Technologies Corporation to print configuration
labels. Scan the labels to change the scanner configuration and data
transfer settings.
Changing a Parameter Setting
Menus of available parameters for each group are listed. Use the scroll bars
to go through the list. Expand each menu (+) to view its parameter settings. Tap a parameter to select, or expand a parameter (+) to view its subparameters.
Note that each parameter or subparameter is shown with its default setting
or current setting in (< >) brackets. Tap a parameter or subparameter to
select that parameter, then do any of the following to change its setting:
Tap Apply to apply any changes. Note that these illustrations are from a
Symbologies parameter.
S Typing a new value in an entry field.
S Choosing a new value from the drop-down list.
S Selecting a different option. The selected option contains a bullet.
S Tap Defaults, then Apply to restore factory-default settings. Tap Yes
when you are prompted to verify this action.
286
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
S Tap Refresh to discard changes and start again. Tap Yes when you are
prompted to verify this action.
About Configuration Parameters
You can find the following information about each configuration parameter:
S Name and Purpose:
Describes the parameter and its function.
S Action:
Describes what to do with a parameter once that parameter is selected.
S SNMP OID:
Lists the SNMP OID for the parameter.
S Syntax or Options:
Syntax lists the two-character code for the parameter, if the parameter is
configurable by scanning a bar code or by sending parameters through a
network. Both Syntax and Options list acceptable values for the parameter. Default settings are noted in italic.
700 Series Color Mobile Computer User’s Manual
287
Appendix A — Control Panel Applets
Data Collection Control Panel Applet
See “Scanner Control and Data Transfer” in the Intermec Windows CE/Pocket
PC Software Developer’ s Kit (SDK) User’ s Manual shipped with the Software Developer’ s Kit (SDK) for information about data collection functions.
Note: Icons are shown to the left.
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the Data Collection icon to access its control panel
applet.
Use the left and right arrows to scroll through the tabs along the bottom of
the control panel applet, then tap a tab to access its menus. These tabs represent the following groups of settings or parameters:
S Symbologies
S Symbology Options (starting on page 309)
S Beeper/LED (starting on page 317)
S Imager (starting on page 323)
S Virtual Wedge (starting on page 325)
288
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Symbologies
You can change bar code symbology parameter settings in your 700 Series
Computer via the Data Collection control panel applet. The following
parameters are for bar code symbologies. Additional information about the
more common bar code symbologies are in Appendix C, “Bar Code
Symbologies.” Note that these parameters are listed in the order of their
appearance within this tab.
Most of these symbologies apply to both the imager and the laser scanner
tools. However, when using an imager, the Macro PDF (page 300), Micro
PDF 417 (page 302), Matrix 2 of 5 (page 304), Telepen (page 305), and
Code 11 (page 306) symbologies are not supported. Likewise, when using
a laser scanner, the QR Code (page 307) and Data Matrix (page 308)
symbologies are not supported.
The following table shows which bar code symbologies are supported either by an imager or by a laser scanner.
Bar Code Symbology
Imager
Laser Scanner
Code 39
Interleaved 2 of 5
Standard 2 of 5
Matrix 2 of 5
Code 128
Code 93
Codabar
MSI
Plessey
UPC
EAN/EAN 128
Code 11
PDF 417
Micro PDF 417
Telepen
Data Matrix
QR Code
700 Series Color Mobile Computer User’s Manual
289
Appendix A — Control Panel Applets
Code 39
Code 39 is a discrete, self-checking, variable length symbology. The character set is uppercase A-Z, 0-9, dollar sign ($), period (.), slash (/), percent
(%), space ( ), plus (+), and minus (-).
Action
Tap (+) to expand the Code 39 parameter, select the setting to be changed,
then tap an option to change this setting or select an option from the
drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.3.1
Options
Decoding
Not active
Active (default)
Format
Standard 43 characters (default)
Full ASCII
Start/Stop
Not transmitted (default)
Transmitted
Start/Stop characters (Not supported when using an imager):
$ (dollar sign) only
* (asterisk) only (default)
& and * (dollar sign and asterisk)
Check digit
Not used (default)
Mod 43 transmitted
Mod 43 not transmitted
French CIP transmitted
French CIP not transmitted
Italian CPI transmitted
Italian CPI not transmitted
Bar code length
Any length (default)
Minimum length
Minimum length
000-254 Minimum length 1-254 (6)
Note: If Bar code length = “1” then Minimum length is entered.
290
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Standard 2 of 5
Standard 2 of 5 is a discrete and self-checking symbology that uses the bars
to encode information and the spaces to separate the individual bars.
Action
Tap (+) to expand the Standard 2 of 5 parameter, select the setting to be
changed, then tap an option to change this setting or select an option from
the drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.4.1
Options
Decoding
Format
Check digit
Bar code length
Minimum length
Fixed length 1
Fixed length 2
Fixed length 3
001-254
000-254
000-254
000-254
Not active (default)
Active
Identicon, 6 start/stop bars (default)
Computer Identics, 4 start/stop
Not used (default)
Mod 10 transmitted
Mod 10 not transmitted
Any length
Minimum length (default)
Fixed lengths
Minimum length 1-254 (6)
Fixed bar code length 0-254 (0)
Fixed bar code length 0-254 (0)
Fixed bar code length 0-254 (0)
Note: If Bar code length = “1” then Minimum length is entered. If Bar
code length = “2” then Fixed length 1, Fixed length 2, or Fixed length 3
is entered.
700 Series Color Mobile Computer User’s Manual
291
Appendix A — Control Panel Applets
Codabar
Codabar is a self-checking, discrete symbology.
Action
Tap (+) to expand the Codabar parameter, select a setting to be changed,
then select an option from the drop-down list to change this setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.5.1
Options
Decoding
Not active (default)
Active
Start/Stop
Not transmitted (default)
abcd transmitted
ABCD transmitted
abcd/tn*e transmitted
DC1`DC4 transmitted
CLSI library system (Not supported when using an imager):
Not active (default)
Active
Check digit
Not used (default)
Transmitted
Not transmitted
Bar code length
Any length
Minimum length (default)
Fixed lengths
Minimum length
003-254
Minimum length 3-254 (6)
Fixed length 1
000-254
Fixed length 0-254 (0)
Fixed length 2
000-254
Fixed length 0-254 (0)
Fixed length 3
000-254
Fixed length 0-254 (0)
Note: If Bar code length = “1” then Minimum length is entered. If Bar
code length = “2” then Fixed length 1, Fixed length 2, or Fixed length 3
is entered.
292
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
UPC/EAN
UPC/EAN are fixed-length, numeric, continuous symbologies that use
four element widths.
Action
Tap (+) to expand the UPC/EAN parameter, select the setting to be
changed, then select an option to change this setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.6.1
Options
UPC A
0 Not active
1 Active (default)
UPC E
0 Not active
1 Active (default)
EAN 8
0 Not active
1 Active (default)
EAN 13
0 Not active
1 Active (default)
Add-on digits
0 Not required (default)
1 Required
Add-on 2 digits
0 Not active (default)
1 Active
Add-on 5 digits (Not supported when using an imager):
0 Not active (default)
1 Active
UPC A check digit
0 Not transmitted
1 Transmitted (default)
UPC E check digit
0 Not transmitted
1 Transmitted (default)
EAN 8 check digit
0 Not transmitted
1 Transmitted (default)
EAN 13 check digit
0 Not transmitted
1 Transmitted (default)
UPC A number system
0 Not transmitted
1 Transmitted (default)
UPC E number system
0 Not transmitted
1 Transmitted (default)
UPC A re-encoding
0 UPC A transmitted as EAN 13 (default)
1 UPC A transmitted as UPC A
UPC E re-encoding
0 UPC E transmitted as UPC E (default)
1 UPC E transmitted as UPC A
EAN 8 re-encoding
0 EAN 8 transmitted as EAN 8 (default)
1 EAN 8 transmitted as EAN 13
700 Series Color Mobile Computer User’s Manual
293
Appendix A — Control Panel Applets
Code 93
Code 93 is a variable length, continuous symbology that uses four element
widths.
Action
Tap the Code 93 parameter, then select an option to change this parameter
setting. Tap (+) to access the Code 93 Lengths parameter.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.7.1
Options
Not active (default)
Active
Code 93 Length
Sets the Code 93 bar code length.
Action
Tap (+) to expand the Code 93 parameter, then tap (+) to expand the
Code 93 Lengths parameter. Tap the setting to be changed, then tap an
option to change this setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.19.1
Options
Bar code length
Minimum length
001-254
Any length (default)
Minimum length
Minimum length 1-254 (6)
Note: If Bar code length = “1” then Minimum length is entered.
294
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Code 128
Code 128 is a variable-length, continuous, high-density, alphanumeric
symbology that uses multiple element widths and supports the extended
ASCII character set.
Action
Tap the Code 128 parameter, then select an option to change this parameter setting. The following illustration is for a 700 Series Computer using a laser scanner.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.9.1
Options
Not active (default)
Active
700 Series Color Mobile Computer User’s Manual
295
Appendix A — Control Panel Applets
Code 128 Options
Set the following for the Code 128 parameter. Note that the EAN 128 ]C1
and CIP 128 French Pharmaceutical options are not available when you use
an imager with your 700 Series Computer.
Action
Tap (+) to expand the Code 128 Options parameter, select a setting, then
select an option to change this setting.
SNMP OID
None.
Options
EAN 128 ]C1 Identifier (disabled when using an imager)
Remove
Include (default)
CIP 128 French Pharmaceutical (disabled when using an imager)
Not active (default)
Active
Bar code length
Any length (default)
Minimum length
Minimum length
001-254 Minimum length 1-254 (6)
296
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Code 128 FNC1 Character
The Code 128 FNC1 character (EAN 128 norms) can be any ASCII character and is used as a separator when multiple identifiers and their fields
are concatenated. Note that this is not available when you use an imager with
your 700 Series Computer.
Non-printable ASCII characters can be entered using the following syntax
where HH is the hexadecimal value of the character.
\xHH
For example, the GS character, whose hexadecimal value is 1D, would be
entered as \x1D. In addition,the following characters have their own identifiers:
S BEL \a
S BS
\b
S FF
\f
S LF
\n
S CR
\r
S HT
\t
S VT
\v
Action
Tap (+) to expand the Code 128 parameter, then type the ASCII characters to be set for the Code 128 FNC1 character parameter.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.21.1
Options
Any ASCII character (default is the GS function character - ID hex)
700 Series Color Mobile Computer User’s Manual
297
Appendix A — Control Panel Applets
Plessey
Plessey is a pulse-width modulated symbology like most other bar codes. It
includes a start character, data characters, an eight-bit cyclic check digit,
and a termination bar. The code is continuous and not self-checking. You
need to configure two parameters for Plessey code: Start Code and Check
Digit. Note that this is not available when you use an imager with your 700
Series Computer.
Action
Tap (+) to expand the Plessey parameter, select the setting to be changed,
then select an option to change this setting or select an option from the
drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.10.1
Options
Decoding
Check digit
Bar code length
Minimum length
001-254
Not active (default)
Active
Not transmitted (default)
Transmitted
Any length (default)
Minimum length
Minimum bar code length 1-254 (6)
Note: If Bar code length = “1” then Minimum length is entered.
298
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
MSI
MSI is a symbology similar to Plessey code (page 298) that includes a start
pattern, data characters, one or two check digits, and a stop pattern. Note
that this is not available when you use an imager with your 700 Series Computer.
Action
Tap (+) to expand the MSI parameter, select the setting to be changed,
then select an option to change this setting or select an option from the
drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.15.1
Options
Decoding
Check digit
Bar code length
Minimum length
001-254
Not active (default)
Active
Mod 10 transmitted (default)
Mod 10 Not transmitted
Double Mod 10 transmitted
Double Mod 10 not transmitted
Any length
Minimum length (default)
Minimum length 1-254 (6)
Note: If Bar code length = “1” then Minimum length is entered.
700 Series Color Mobile Computer User’s Manual
299
Appendix A — Control Panel Applets
PDF 417
PDF 417 is a stacked two-dimensional symbology that provides the ability
to scan across rows of code. Each row consists of start/stop characters, row
identifiers, and symbol characters, which consist of four bars and four
spaces each and contain the actual data. This symbology uses error correction symbol characters appended at the end to recover loss of data.
Because the virtual wedge translates incoming data into keypad input, the
size of the keypad buffer limits the effective length of the label to 128
characters. Longer labels may be truncated. For PDF 417 labels of more
than 128 characters, you can develop an application that bypasses the keypad buffer.
Action
Tap the PDF 417 parameter, then select an option to change this parameter setting. Tap (+) to access either the Macro PDF options parameter or
the Micro PDF 417 parameter.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.17.1
Options
Not active
Active (default)
Macro PDF options
Macro PDF is used when a long message requires more than one PDF 417
label. Note that this is not available when you use an imager with your 700
Series Computer.
S Select Buffered to store a multi-label PDF 417 message in the Sabre
buffer, thus transmitting the entire message when all labels have been
read.
300
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
S Select Unbuffered for multi-label PDF 417 messages that are too long
for the Sabre buffer (memory overflow). Each part of the PDF 417 label
is transmitted separately, and the host application must then assemble
the message using the macro PDF control header transmitted with each
label. Control Header is only present in macro PDF codes and is always
transmitted with unbuffered option.
Action
Tap (+) to expand the PDF 417 parameter, tap (+) to expand the Macro
PDF parameter, select a setting to be changed, then select an option to
change this setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.22.1
Options
Macro PDF
Control header
File name
Segment count
Time stamp
Sender
Addressee
File size
Checksum
700 Series Color Mobile Computer User’s Manual
Unbuffered
Buffered (default)
Not transmitted (default)
Transmitted
Not transmitted (default)
Transmitted
Not transmitted (default)
Transmitted
Not transmitted (default)
Transmitted
Not transmitted (default)
Transmitted
Not transmitted (default)
Transmitted
Not transmitted (default)
Transmitted
Not transmitted (default)
Transmitted
301
Appendix A — Control Panel Applets
Micro PDF 417
Micro PDF 417 is a multi-row symbology derived from and closely based
on PDF 417 (page 300). A limited set of symbology sizes is available, together with a fixed level of error correction for each symbology size. Note
that this is not available when you use an imager with your 700 Series Computer.
Action
Tap (+) to expand the PDF 417 parameter, tap (+) to expand the Micro
PDF 417 parameter, select a setting to be changed, then select an option
to change this setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.27.1
Options
Decoding
Code 128 Emulation
302
Not active (default)
Active
Not active (default)
Active
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Interleaved 2 of 5
Interleaved 2 of 5 (I 2 of 5) is a high-density, self-checking, continuous,
numeric symbology used mainly in inventory distribution and the automobile industry.
Note: An Interleaved 2 of 5 bar code label must be at least three characters
long for the 700 Series Computer to scan and decode correctly.
Action
Tap (+) to expand the Interleaved 2 of 5 parameter, select the setting to be
changed, then tap an option to change this setting or select an option from
the drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.23.1
Options
Decoding
Not active (default)
Active
Check digit
Not used (default)
Mod 10 transmitted
Mod 10 not transmitted
French CIP transmitted
French CIP not transmitted
Bar code length
Any length
Minimum length (default)
Fixed lengths
Minimum length 003-254 Minimum length 3-254 (6)
Fixed length 1
003-254 Fixed length 3-254 (0)
Fixed length 2
003-254 Fixed length 3-254 (0)
Fixed length 3
003-254 Fixed length 3-254 (0)
Note: If Bar code length = “1” then Minimum length is entered. If Bar
code length =“2” then Fixed length 1, Fixed length 2, or Fixed length 3 is
entered.
700 Series Color Mobile Computer User’s Manual
303
Appendix A — Control Panel Applets
Matrix 2 of 5
Matrix 2 of 5 is a numerical symbology. Note that this is not available when
you use an imager with your 700 Series Computer.
Action
Tap (+) to expand the Matrix 2 of 5 parameter, select the setting to be
changed, then tap an option to change this setting or select an option from
the drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.24.1
Options
Decoding
Bar code length
Minimum length
001-254
Not active (default)
Active
Any length
Minimum length (default)
Minimum length 1-254 (6)
Note: If Bar code length = “1” then Minimum length is entered.
304
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Telepen
Telepen is an alphanumeric, case-sensitive, full ASCII symbology. Note that
this is not available when you use an imager with your 700 Series Computer.
Action
Tap (+) to expand the Telepen parameter, select the setting to be changed,
then tap an option to change this setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.25.1
Options
Decoding
Format
Not active (default)
Active
ASCII (default)
Numeric
700 Series Color Mobile Computer User’s Manual
305
Appendix A — Control Panel Applets
Code 11
Code 11 is a high density, discrete numeric symbology that is extensively
used in labeling telecommunications components and equipment. Note
that this is not available when you use an imager with your 700 Series Computer.
Action
Tap (+) to expand the Code 11 parameter, select the setting to be changed,
then tap an option to change this setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.26.1
Options
Decoding
Check digit verification
Check digit transmit
306
Not active (default)
Active
1 digit (default)
2 digits
Disable (default)
Enable
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
QR Code
QR Code (Quick Response Code) is a two-dimensional matrix symbology
containing dark and light square data modules. It has position detection
patterns on three of its four corners and features direct encodation of the
Japanese Kana-Kanji character set. It can encode up to 2509 numeric or
1520 alphanumeric characters and offers three levels of error detection.
Note that this is not available when you use a laser scanner with your 700 Series Computer.
Action
Tap (+) to expand the QR Code parameter, select the setting to be
changed, then tap an option to change this setting or select an option from
the drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.35.1
Options
Decoding 0 Not active
1 Active (default)
700 Series Color Mobile Computer User’s Manual
307
Appendix A — Control Panel Applets
Data Matrix
A two-dimensional matrix symbology, which is made of square modules
arranged within a perimeter finder pattern. The symbology utilizes Error
Checking and Correcting (ECC) algorithm with selectable levels for data
error recovery and Cyclic Redundancy Check algorithm to validate the data. The character set includes either 128 characters conforming to ISO
646 (ANSI X3.4 - 1986) or 256 extended character set. Maximum capacity of a symbol is 2335 alphanumeric characters, 1556 8-bit byte characters or 3116 numeric digits. Note that this is not available when you use a
laser scanner with your 700 Series Computer.
Action
Tap (+) to expand the Data Matrix parameter, select the setting to be
changed, then tap an option to change this setting or select an option from
the drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.34.1
Options
Decoding 0 Not active
1 Active (default)
308
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Symbology Options
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the Data Collection icon to access its control panel
applet.
Use the right and left arrows to scroll to the Symbology Options tab, then
tap this tab to access its parameters. The following are parameters for bar
code symbology options. Note that these are listed in the order of their
appearance within the Symbology Options tab.
Symbology ID
Identifies the bar code symbology in which data has been encoded by prepending a user-specified symbology identifier to the data. You can prepend
one of these types of character strings to identify the symbology:
S User-defined ASCII Character (Option 1):
A user-defined symbology identifier is a single ASCII character. You can
assign a custom identifier character to each bar code symbology. Note
that this is not available when you use an imager with your 700 Series
Computer.
S AIM ISO/IEC Standard (Option 2 - Required to define symbology IDs):
The AIM Standard has a three-character structure which indicates the
symbology and optional features. See the AIM ISO/IEC Standard for
more information.
Action
Select Symbology ID, then select an option to change this parameter setting. Tap (+) to expand the Symbology ID parameter, then select any of
the user ID parameters listed. See the top of the next page for a sample screen
of the Code 39 user ID.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.4.1.22.1
Options
Disable (default)
User defined (disabled when using an imager)
ISO/IEC Standard
700 Series Color Mobile Computer User’s Manual
309
Appendix A — Control Panel Applets
Code 39 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Code 39 bar code data. Note that this is not
available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Code 39 user
ID parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.3.1
Options: x
where x is a single ASCII character. Default is asterisk (*).
Code 128 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Code 128 bar code data. Note that this is not
available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Code 128 user
ID parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.5.1
Options: x
where x is a single ASCII character. Default is asterisk (*).
Codabar User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Codabar bar code data. Note that this is not
available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Codabar user
ID parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.2.1
Options: x
310
where x is a single ASCII character. Default is D.
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Code 93 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Code 93 bar code data. Note that this is not
available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Code 93 user
ID parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.4.1
Options: x
where x is a single ASCII character. Default is asterisk (*).
Interleaved 2 of 5 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Interleaved 2 of 5 bar code data. Note that this
is not available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Interleaved 2
of 5 user ID parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.10.1
Options: x
where x is a single ASCII character. Default is I (not lowercase L).
PDF-417 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify PDF 417 bar code data. Note that this is not
available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the PDF 417 user
ID parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.12.1
Options: x
where x is a single ASCII character. Default is an asterisk (*).
MSI User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify MSI bar code data. Note that this is not available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the MSI user ID
parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.11.1
Options: x
where x is a single ASCII character. Default is D.
700 Series Color Mobile Computer User’s Manual
311
Appendix A — Control Panel Applets
Plessey User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Plessey bar code data. Note that this is not available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Plessey user ID
parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.13.1
Options: x
where x is a single ASCII character. Default is D.
Standard 2 of 5 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Standard 2 of 5 bar code data. Note that this is
not available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Standard 2 of
5 user ID parameter, then enter a user ID value to change this parameter
setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.23.1
Options: x
where x is a single ASCII character. Default is D.
UPC A User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify UPC-A (Universal Product Code) bar code
data. Note that this is not available when you use an imager with your 700
Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the UPC A user ID
parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.6.1
Options: x
where x is a single ASCII character. Default is A.
UPC E User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify UPC-E bar code data. Note that this is not
available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the UPC E user ID
parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.7.1
Options: x
312
where x is a single ASCII character. Default is E.
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
EAN 8 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify EAN-8 bar code data. Note that this is not
available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the EAN 8 user ID
parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.8.1
Options: x
where x is a single ASCII character. Default is \xFF.
EAN 13 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify EAN-13 (European Article Numbering) bar
code data. Note that this is not available when you use an imager with your
700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the EAN 13 user
ID parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.9.1
Options: x
where x is a single ASCII character. Default is F.
Matrix 2 of 5 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Matrix 2 of 5 bar code data. Note that this is
not available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Matrix 2 of 5
user ID parameter, then enter a user ID value to change this parameter
setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.24.1
Options: x
where x is a single ASCII character. Default is D.
Telepen User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Telepen bar code data. Note that this is not
available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Telepen user
ID parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.25.1
Options: x
where x is a single ASCII character. Default is an asterisk (*).
700 Series Color Mobile Computer User’s Manual
313
Appendix A — Control Panel Applets
Code 11 User ID
If “1” was selected in the Symbology ID parameter, you can set your own
ASCII character to identify Code 11 bar code data. Note that this is not
available when you use an imager with your 700 Series Computer.
Action: Tap (+) to expand the Symbology ID parameter, select the Code 11 user
ID parameter, then enter a user ID value to change this parameter setting.
SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.16.1
Options: x
314
where x is a single ASCII character. Default is asterisk (*).
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Prefix
Prepends a string of up to 20 ASCII characters to all scanned data.
Action
Tap the Prefix parameter, then enter a prefix value to change this parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.4.1.29.1
Options
Acceptable values are up to 20 ASCII characters.
Embedded null () characters are not allowed.
Default is no characters (disabled).
700 Series Color Mobile Computer User’s Manual
315
Appendix A — Control Panel Applets
Suffix
Appends a string of up to 20 ASCII characters to all scanned data.
Action
Tap the Suffix parameter, then enter a suffix value to change this parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.4.1.30.1
Options
Acceptable values are up to 20 ASCII characters. Embedded null () characters are not allowed. Default is no characters (disabled).
316
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Beeper/LED
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the Data Collection icon to access its control panel
applet.
Use the right and left arrows to scroll to the Beeper/LED tab, then tap this
tab to access its parameters.
Most of these functions are not available when using an imager. The following
table shows which functions are supported either by an imager or by a laser
scanner.
Beeper Function
Imager
Laser Scanner
Beeper Volume
Beeper Frequency
Good Read Beeps
Good Read Beep Duration
The following are parameters for features on the 700 Series Computer.
Note that these are listed in the order of their appearance.
700 Series Color Mobile Computer User’s Manual
317
Appendix A — Control Panel Applets
Beeper Volume
Sets the volume for the good read beep.
Action
Tap the Beeper volume parameter, then select an option to change this parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.1.4.1.6.1
Laser Scanner Options
318
Low
High (default)
Medium
Off
Vibrate
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Imager Options
Beeper (default)
Vibrate
Silencing the Beeper Volume
To turn the beeper off, tap Start → Settings → the Personal tab →
Sounds and Notifications → the Volume tab, drag the System volume
slider bar to the left “Silent” position, then tap ok to exit this applet.
700 Series Color Mobile Computer User’s Manual
319
Appendix A — Control Panel Applets
Beeper Frequency
Sets the frequency for the good read beep. Note that this is not available
when you use an imager with your 700 Series Computer.
Action
Tap the Beeper frequency parameter, then enter a frequency value to
change this parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.1.4.1.7.1
Options
1000-4095 (default is 2090)
320
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Good Read Beeps
Sets the number of good read beeps. Note that this is not available when you
use an imager with your 700 Series Computer.
Action
Tap the Good read beeps parameter, then select an option to change this
parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.1.4.1.8.1
Options
No beeps
One beep (default)
Two beeps
700 Series Color Mobile Computer User’s Manual
321
Appendix A — Control Panel Applets
Good Read Beep Duration
Sets the duration of the good read beep. Note that this is not available when
you use an imager with your 700 Series Computer.
Action
Tap the Good read beep duration parameter, then enter a duration value
to change this parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.1.4.1.9.1
Options
0`2550
322
Beep duration in milliseconds. (default is 80)
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Imager
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the Data Collection icon to access its control panel
applet.
Use the right and left arrows to scroll to the Imager tab, then tap this tab
to access its parameters.
The following are parameters for the imager. Note that these are listed in
the order of their appearance within the Imager tab.
Aimer LED duration
The Aimer LED duration controls the time the Aimer LED is turned on
when the scan button is pressed. After this time, images are captured for
decoding. The purpose is to position the Aimer LED on the bar code symbol before attempting to decode the bar code. Note that this is not available
when you use a laser scanner with your 700 Series Computer.
Action
Tap the Aimer LED duration parameter, then enter a value to change this
setting. Note that values must be in 50 ms increments, such as 500, 650,
or 32500. Values not entered in 50 ms increments will be rounded down.
For example, 2489 ms would be rounded down to 2450 ms, 149 ms
would be rounded down to 100 ms, etc..
SNMP OID
1.3.6.1.4.1.1963.15.3.3.3.1.1.21.1
Options
0-65500 ms (Default is 0)
700 Series Color Mobile Computer User’s Manual
323
Appendix A — Control Panel Applets
Image Dimension
The image dimensions control the horizontal size of the image for decoding. This can restrict the image to one bar code when otherwise, there
might be more than one bar code in the image to be decoded. Note that
this is not available when you use a laser scanner with your 700 Series Computer.
Action
Tap the Image dimension parameter, select the position to be changed,
then tap an option or enter a value to change this position.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.3.1.1.22.1
Options
Left position
Right position
Top position
Bottom position
324
0-478
0-479
Not supported
Not supported
Position in pixels (0)
Position in pixels (479)
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Virtual Wedge
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the Data Collection icon to access its control panel
applet.
Use the right and left arrows to scroll to the Virtual Wedge tab, then tap
this tab to access its parameters.
The following are parameters for the virtual wedge scanner. Note that these
are listed in the order of their appearance within the Virtual Wedge tab.
Virtual Wedge
Enables or disables the virtual wedge for the internal scanner. The virtual
wedge retrieves scanned Automatic Data Collection (ADC) data and sends
it to the keypad driver so that the 700 Series Computer can receive and
interpret the data as keypad input.
Because the virtual wedge translates incoming data into keypad input, the
size of the keypad buffer limits the effective length of the label to 128
characters. Longer labels may be truncated. For labels of more than 128
characters, you need to develop an application that bypasses the keypad
buffer.
Action
Tap the Virtual Wedge parameter, then tap an option to change this parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.2.1.1.2.1
Options
Disable
Enable (default)
700 Series Color Mobile Computer User’s Manual
325
Appendix A — Control Panel Applets
Preamble
Sets the preamble that precedes any data you scan with the 700 Series
Computer. Common preambles include a data location number or an operator number.
Action
Tap the Preamble parameter, then enter a preamble value to change this
parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.2.1.1.3.1
Syntax
ADdata
where data is acceptable values up to 31 ASCII characters. Embedded null
() characters are not allowed. Default is no characters (disabled).
Note: When you enter the AD command without data, the preamble is
disabled. If you want to use quotation marks or the following combinations of characters as part of the appended data, separate those characters
from the AD command with quotes. If you do not use quotes as described
here, the 700 Series Computer will interpret the characters as another configuration command:
AD
AE
AF
KC
BV
EX
DF
EXAMPLE:
To use the two-character string BV as a preamble, scan this command (as a
Code 39 label) or send this command through the network: $+AD“BV”
326
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Postamble
Sets the postamble that is appended to any data you scan with the 700 Series Computer. Common postambles include cursor controls, such as tabs
or carriage return line feeds.
Action
Tap the Postamble parameter, then enter a postamble value to change this
parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.2.1.1.4.1
Syntax
AEdata
where data is any acceptable values up to 31 ASCII characters. Embedded
null () characters are not allowed. Default is the tab character (\t).
Note: When you enter the AE command without data, the postamble is
disabled. If you want to use quotation marks or the following combinations of characters as part of the appended data, separate those characters
from the AE command with quotes. If you do not use quotes as described
here, the 700 Series Computer will interpret the characters as another configuration command.
AD
AE
AF
KC
BV
EX
DF
EXAMPLE:
To use the two-character string BV as a postamble, scan this command (as
a Code 39 label) or send this command through the network: $+AE“BV”
700 Series Color Mobile Computer User’s Manual
327
Appendix A — Control Panel Applets
Grid
Sets the virtual wedge grid, which filters the data coming from this 700
Series Computer. The data server supports data filtering, which allows you
to selectively send scanned data. The virtual wedge grid is similar to the
“format” argument of the C Runtime Library scan function.
Action
Tap the Grid parameter, then enter a grid value to change this parameter
setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.2.1.1.5.1
Syntax
AF filter-expression= > editing-expression
where:
S 
The AIM symbology ID.
S filter-expression
Any character string that includes valid filter expression values, and editing-expression is any character string that includes valid editing expression values.
S 
Any positive integer or NULL. A NULL width means that the field type
(defined next) applies all the way to the end of the data string. A nonNULL width means that the field applies to that many characters of data. The grid can be up to 240 characters in length. Default is NULL.
328
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Code Page
Sets the virtual wedge code page. The code page controls the translation
from the character set of the raw collected data to Unicode, which is the
character set expected by Windows CE applications. The default code page
is 1252, which is the Windows Latin 1 (ANSI) character set.
Action
Tap the Code Page parameter, then select an option to change this parameter setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.2.1.1.6.1
Options
The only acceptable value for the code page parameter is “1252,” which is
the default.
700 Series Color Mobile Computer User’s Manual
329
Appendix A — Control Panel Applets
SNMP Control Panel Applet
Simple Network Management Protocol (SNMP) parameters include identification information, security encryption, security community strings,
and traps.
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the SNMP icon to access its control panel applet.
Tap a tab to access its menus. These tabs represent three groups of settings
or parameters:
S Security (starting on the next page)
S Traps (starting on page 336)
S Identification (starting on page 338)
330
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Security
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the SNMP icon → the Security tab to access its
parameters.
The following are parameters that affect encryption and community
strings. Note that these are listed in the order of their appearance within the
Security tab.
Read Only Community
Sets the read-only community string for this 700 Series Computer, which
is required for processing of SNMP get and get next requests.
Action
Tap the Read Only Community parameter, then enter a community string
to change this parameter setting.
SNMP OID
1.3.6.1.4.1.1963.10.5.1.2.0
Options
The read-only community string can be up to 128 ASCII characters. Default is Public.
700 Series Color Mobile Computer User’s Manual
331
Appendix A — Control Panel Applets
Read/Write Community
Sets the read/write community string, which is required for processing of
SNMP set requests by this 700 Series Computer. An SNMP packet with
this name as the community string will also process SNMP get and next
requests.
Action
Tap the Read/Write Community parameter, then enter a community
string to change this parameter setting.
SNMP OID
1.3.6.1.4.1.1963.10.5.1.3.0
Options
The read/write community string can be up to 128 ASCII characters. Default is Private.
332
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Read Encryption
Sets the packet-level mode of security for SNMP read-only requests. If you
enable read encryption, all received SNMP get and get next packets have
to be encrypted or the packet will not be authorized. If encryption is enabled, you can only use software provided by Intermec Technologies.
Note: To enable security encryption, you also need to set the Security Encryption Key (page 335).
Action
Tap the Read Encryption parameter, then select an option to change this
parameter setting.
SNMP OID
1.3.6.1.4.1.1963.10.5.1.4.0
Options
On SNMP get and get next packets must be encrypted
Off SNMP packets do not have to be encrypted (default)
700 Series Color Mobile Computer User’s Manual
333
Appendix A — Control Panel Applets
Write Encryption
Sets the packet-level mode of security for SNMP read/write requests. If
you enable write encryption, all SNMP packets that are received with the
read/write community string have to be encrypted or the packet will not
be authorized. You need to use software from Intermec Technologies that
supports encryption.
Note: To enable security encryption, you also need to set the Security Encryption Key (page 335).
Action
Tap the Write Encryption parameter, then select an option to change this
parameter setting.
SNMP OID
1.3.6.1.4.1.1963.10.5.1.5.0
Options
334
On SNMP packets must be encrypted
Off SNMP packets do not have to be encrypted (default)
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Encryption Key
Identifies the key that this 700 Series Computer uses to encrypt or decipher SNMP packets. Encryption is used only by software provided by Intermec Technologies. If encryption is enabled, SNMP management platforms will not be able to communicate with the 700 Series Computer. The
encryption key is returned encrypted.
Action
Tap the Encryption Key parameter, then enter a security encryption key
value to change this parameter setting.
Note: You also need to set either Read Encryption (page 333) or Write
Encryption (page 334) or both.
SNMP OID
1.3.6.1.4.1.1963.10.5.1.6.0
Options
The encryption key can be from 4 to 20 ASCII characters. Default is
NULL.
700 Series Color Mobile Computer User’s Manual
335
Appendix A — Control Panel Applets
Traps
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the SNMP icon → the Traps tab to access its
parameters.
The following are authentication and threshold parameters for traps. Note
that these are listed in the order of their appearance within the Traps tab.
Authentication
Determines whether to send authentication traps. When trap authentication is enabled, an authentication trap is sent if an SNMP packet is received by the master agent with an invalid community string.
Action
Tap the Authentication parameter, then select an option to change this
parameter setting.
SNMP OID
1.3.6.1.4.1.1963.10.5.2.2.0
Options
336
On (default)
Off
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Threshold
Determines the maximum number of traps per second that the master
agent generates. If the threshold is reached, the trap will not be sent.
Action
Tap the Threshold parameter, then enter a threshold value to change this
parameter setting.
SNMP OID
1.3.6.1.4.1.1963.10.5.2.3.0
Options
Any positive integer value. Default is 10.
700 Series Color Mobile Computer User’s Manual
337
Appendix A — Control Panel Applets
Identification
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the SNMP icon → the Identification tab to access
its parameters.
The following are parameters for contact, location, and name information
for support purposes. Note that these are listed in the order of their appearance within the Identification tab.
Contact
Sets the contact information for the person responsible for this 700 Series
Computer.
Action
Tap the Contact parameter, then enter the name of your contact representative to change this parameter setting.
SNMP OID
1.3.6.1.2.1.1.4.0
Options
The identification contact may be up to 255 ASCII characters. Default is
no characters or blank.
338
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Name
Sets the assigned name for this 700 Series Computer.
Action
Tap the Name parameter, then enter the name of your 700 Series Computer to change this parameter setting.
SNMP OID
1.3.6.1.2.1.1.5.0
Options
The identification name may be up to 255 ASCII characters. Default is no
characters or blank.
700 Series Color Mobile Computer User’s Manual
339
Appendix A — Control Panel Applets
Location
Sets the identification location for this 700 Series Computer, such as
“Shipping.”
Action
Tap the Location parameter, then enter the location of where your 700
Series Computer to change this parameter setting.
SNMP OID
1.3.6.1.2.1.1.6.0
Options
The identification location may be up to 255 ASCII characters. Default is
no characters or blank.
340
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Unit Information Control Panel Applet
Unit Information is a read-only control panel applet that provides information about your 700 Series Computer, such as software version builds,
available CAB files, and the internal battery status.
This control panel applet is only available in the 700 Series Computer if
Intermec Content is enabled, the Plus region is enabled and installed, and
a laser scanner is installed.
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the Unit Information icon to access its control panel
applet.
Tap a tab to access its menus. These tabs represent three groups of settings
or parameters:
S Versions (starting on the next page)
S Battery Status (starting on page 343)
S CAB Files (starting on page 344)
700 Series Color Mobile Computer User’s Manual
341
Appendix A — Control Panel Applets
Versions
You can view the latest software build version on your 700 Series
Computer by accessing the Unit Information control panel applet.
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the Unit Information icon → the Versions tab to
view the latest software build version. Tap ok to exit this information.
Below are some of the software applications you may find on this screen:
S 700 Platform Build:
Shows the latest development or released version of the software build
for the 700 Series Computer.
S S9C:
Provides the name and version of the scanner file built into this 700 Series Computer, along with the current CPU version.
S DataCollection Build:
Shows the latest development or released version of the software build
for the Data Collection control panel applet.
342
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
Battery Status
You can view the battery status for your 700 Series Computer by accessing
the Unit Information control panel applet. Unit Manager applications are
available on the 700 Series Color Unit Manager CD-ROM. For more
information, consult your Intermec sales representative.
To access the settings from the 700 Series Computer, tap Start → Settings
→ the System tab → the Unit Information icon → the Battery Status tab
to view the current status. Tap ok to exit this information.
700 Series Color Mobile Computer User’s Manual
343
Appendix A — Control Panel Applets
CAB Files
You can view the latest developer or released version of each CAB file from
Intermec Technologies Corporation that are installed in your 700 Series
Computer via the Unit Information control panel applet. Custom CAB
files are not displayed in this applet. See the Software Tools User’ s Manual for
more information about these files.
To access the information from the 700 Series Computer, tap Start →
Settings → the System tab → the Unit Information icon → the CAB
Files tab to view the current CAB file versions. Tap ok to exit this
information.
When a CAB file is built, a registry entry is created with a build number
for that file. This CAB Files control panel applet looks for a registry key
for each CAB file installed. When the registry entry is found, the CAB file
name and version number information are displayed. If a CAB file has not
been installed, then its information is not displayed.
Below is a list of CAB files from Intermec Technologies that are available
for your 700 Series Computer with their latest developer or released version of the software build. Should you need to add any of these to your
700 Series Computer, contact an Intermec representative.
S BtMainStack:
Installation of the Main Bluetooth Stack is handled automatically as part
of the operating system boot-up procedure. See Chapter 4, “Network
Support,” for more information about Bluetooth wireless printing.
S Comm Port Wedge:
The software build for the Comm Port Wedge. Note that the Comm Port
Wedge CAB file is available on the 700C Tools CD.
S NPCPTest:
This installs a Norand Portable Communications Protocol (NPCP)
Printing test application which will print to an Intermec 4815, 4820,
or 6820 Printer. See Chapter 5, “Printer Support,” for more information.
344
700 Series Color Mobile Computer User’s Manual
Appendix A — Control Panel Applets
S PDWPM0C:
This is the installer for the Wireless Printing Demo application. To run
this demonstration, tap Start → Programs → the Wireless Printing
Demo icon. Press Help in the demo application for more information.
S S9C Upgrade:
Installs the files needed to upgrade the S9C scanner firmware. See the
Recovery CD Help for more information about upgrading the firmware.
S SDK:
Installs the Intermec Software Developer’ s Kit (SDK). See the SDK
User’ s Manual for more information.
S Unit Manager:
Installs the Unit Manager application which provides tools for remotely
managing the 700 Series Computer. Unit Manager applications are
available on the 700 Series Color Unit Manager CD-ROM. For more information, consult your Intermec sales representative.
S Unit Manager Help:
Installs the online help for the Unit Manager application.
S WinCfg:
Configures the NRINET.INI file, launches the NRINet client, and
loads and unloads the LAN and WLAN device drivers. See the Windows
95 and Windows CE Configuration Utilities Reference Manual (P/N:
978-054-010) for more information.
S Wireless Printing Sample:
Installs a sample application that developers can use for reference when
they are developing their own Wireless Printing applications. The source
code for this application is included as part of the Wireless Printing
SDK on the 700C Tools CD. See the SDK User’ s Manual for more information.
S ActiveX Control Tools:
This lists some of the CAB files that may be available with which to
install ActiveX Control Tools. See the SDK Online Help for more information.
S AXCommunication:
Communication controls that transmit or receive messages from input connections.
S AXFileTransfer:
File transfer controls that transmit and receive files using the Trivial
File Transfer Protocol (TFTP).
S AXReaderCommand:
Reader command functions that modify and retrieve configuration
information from your 700 Series Computer.
S AXVWedge:
The virtual wedge control that retrieves scanned ADC data and sends
it to the keyboard driver to interpret data as keyboard input.
700 Series Color Mobile Computer User’s Manual
345
Appendix A — Control Panel Applets
346
700 Series Color Mobile Computer User’s Manual
B
Unit Manager
Configuration parameters are also configurable using a Unit Manager application which accesses the 700 Series Computer through a web browser
on your desktop PC via the SRDEVMGMT.CAB file.
Unit Manager applications are available on the 700 Series Color Unit
Manager CD-ROM. For more information, consult your Intermec sales
representative.
Note: Parameter information, such as SNMP OID and options, is detailed
in Appendix A, “Control Panel Applets.”
700 Series Color Mobile Computer User’s Manual
347
Appendix B — Unit Manager
Data Collection
Within the Unit Manager, click Configuration from the left navigation
bar, then click the Data Collection icon to access any of these tabs:
Symbologies, Symbology ID, Beeper/LED, or Virtual Wedge.
Symbologies
Within the Unit Manager, select Configuration Management → Data
Collection, then click the Symbologies tab to access the following parameters. Options for these parameters are listed on the page provided. These
are listed in alphabetical order.
S Codabar (page 292)
S Code 11 (page 306)
S Code 128 (page 295)
S Code 128 Options (page 296)
S Code 128 FNC1 Character (page 297)
S Code 39 (page 290)
S Code 93 (page 294)
S Code 93 Length (page 294)
S Data Matrix (page 308)
S Interleaved 2 of 5 (page 303)
S Matrix 2 of 5 (page 304)
S MSI (page 299)
S PDF 417 (page 300)
S Macro PDF (page 300)
S Micro PDF 417 (page 302)
S Plessey (page 298)
S QR Code (page 307)
S Standard 2 of 5 (page 291)
S Telepen (page 305)
S UPC/EAN (page 293)
348
700 Series Color Mobile Computer User’s Manual
Appendix B — Unit Manager
Symbology ID
Within the Unit Manager, select Configuration Management → Data
Collection, then click the Symbology ID tab to access the following
parameters. Options for these parameters are listed on the page provided.
These are listed in alphabetical order.
S Prefix (page 315)
S Suffix (page 316)
S Symbology ID (page 309)
S Codabar user ID (page 310)
S Code 11 user ID (page 314)
S Code 128 user ID (page 310)
S Code 39 user ID (page 310)
S Code 93 user ID (page 311)
S EAN-13 user ID (page 313)
S EAN-8 user ID (page 313)
S Interleaved 2 of 5 user ID (page 311)
S Matrix 2 of 5 user ID (page 313)
S MSI user ID (page 311)
S PDF 417 user ID (page 311)
S Plessey user ID (page 312)
S Standard 2 of 5 user ID (page 312)
S Telepen user ID (page 313)
S UPC-A user ID (page 312)
S UPC-E user ID (page 312)
Beeper/LED
Within the Unit Manager, select Configuration Management → Data
Collection, then click the Beeper/LED tab to access the following
parameters. Options for these parameters are listed on the page provided.
These are listed in alphabetical order.
S Beeper Frequency (page 320)
S Beeper Volume (page 318)
S Good Read Beep Duration (page 322)
S Good Read Beeps (page 321)
700 Series Color Mobile Computer User’s Manual
349
Appendix B — Unit Manager
Imager
Within the Unit Manager, select Configuration Management → Data
Collection, then click the Imager tab to access the following parameters.
Options for these parameters are listed on the page provided. These are
listed in alphabetical order.
S Aimer LED Duration (page 323)
S Image Dimension (page 324)
Virtual Wedge
Within the Unit Manager, select Configuration Management → Data
Collection, then click the Virtual Wedge tab to access the following
parameters. Options for these parameters are listed on the page provided.
These are listed in alphabetical order.
S Code Page (page 329)
S Grid (page 328)
S Postamble (page 327)
S Preamble (page 326)
S Virtual Wedge (page 325)
SNMP
Within the Unit Manager, click Configuration from the left navigation
bar, then click the SNMP icon to access any of these tabs: Security, Traps,
or Identification.
Security
Within the Unit Manager, select Configuration Management → SNMP,
then click the Security tab to access the following parameters. Options for
these parameters are listed on the page provided. These are listed in alphabetical order.
S Encryption Key (page 335)
S Read Encryption (page 333)
S Read Only Community (page 331)
S Read/Write Community (page 332)
S Write Encryption (page 334)
350
700 Series Color Mobile Computer User’s Manual
Appendix B — Unit Manager
Traps
Within the Unit Manager, select Configuration Management → SNMP,
then click the Traps tab to access the following parameters. Options for
these parameters are listed on the page provided. These are listed in alphabetical order.
S Authentication (page 336)
S Threshold (page 337)
Identification
Within the Unit Manager, select Configuration Management → SNMP,
then click the Identification tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed
in alphabetical order.
S Contact (page 338)
S Location (page 340)
S Name (page 339)
700 Series Color Mobile Computer User’s Manual
351
Appendix B — Unit Manager
Unit
Within the Unit Manager, click Configuration from the left navigation
bar, then click the Unit icon to access any of these tabs: Date/Time, Display, Keypad, Power Management, or Speaker.
Date/Time
Sets the current date and time.
Action
Click the Date/Time tab, then select Date or Time and make changes in
the entry field, or tap (+) to expand either the Date or Time parameter,
select the setting to be changed, then select a value from the drop-down
list or enter a new value to change this setting.
SNMP OID
Date:
Time:
1.3.6.1.4.1.1963.15.501.2.1.0
1.3.6.1.4.1.1963.15.501.2.2.0
Options
Date
Time
352
Year
Month
Day
Hour
Minute
Second
0000`999
1-12 (6)
1-31 (1)
0-23 (0)
0-59 (00)
0-59 (00)
(1999)
700 Series Color Mobile Computer User’s Manual
Appendix B — Unit Manager
Backlight Timeout
Sets the length of time that the display backlight remains on. If you set a
longer timeout value, you use the battery power at a faster rate.
Action
Click the Display tab, then select an option from the Backlight timeout
drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.13.1.0
Syntax
DFdata
where data is any of the following:
10
30
60
120
180
240
300
10 seconds
30 seconds
1 minute (default)
2 minutes
3 minutes
4 minutes
5 minutes
700 Series Color Mobile Computer User’s Manual
353
Appendix B — Unit Manager
Key Clicks
Enables or disables the keypad clicks. The 700 Series Computer emits a
click each time you press a key or decode a row of a two-dimensional
symbology.
Action
Click the Keypad tab, then select an option from the Key clicks dropdown list.
SNMP OID
1.3.6.1.4.1.1963.15.12.1.0
Syntax
KCdata
where data is any of the following:
354
Disable clicks
Enable soft key clicks
Enable loud key clicks (default)
700 Series Color Mobile Computer User’s Manual
Appendix B — Unit Manager
Automatic Shutoff
Sets the length of time the 700 Series Computer remains on when there is
no activity. When you turn on the 700 Computer, it either resumes exactly
where it was when you turned it off or boots and restarts your application.
Action
Click the Power Management tab, then select an option from the Automatic shutoff drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.11.3.0
Syntax
EZdata
where data is any of the following:
1 minute
2 minutes
3 minutes (default)
4 minutes
5 minutes
700 Series Color Mobile Computer User’s Manual
355
Appendix B — Unit Manager
Volume
Changes the volume of all audio signals.
Action
Click the Speaker tab, then select an option from the Volume drop-down
list.
SNMP OID
1.3.6.1.4.1.1963.15.3.1.3.0
Syntax
BVdata
where data is any of the following:
356
Off
Very quiet
Quiet
Normal (default)
Loud
Very loud
700 Series Color Mobile Computer User’s Manual
Appendix B — Unit Manager
Using Reader Commands
After the 700 Series Computer is connected to your network, you can send
the 700 Series Computer a reader command from an application to perform a task, such as changing the time and date. Some reader commands
temporarily override the configuration settings and some change the configuration settings.
Change Configuration
The Change Configuration command must precede any configuration
command. If you enter a valid string, the 700 Series Computer configuration is modified and the computer emits a high beep. To send the Change
Configuration command through the network, use the $+ [command]
syntax where command is the two-letter command syntax for the configuration command followed by the value to be set for that command.
You can also make changes to several different commands by using the
$+ [command]...[command n] syntax. There are seven configuration
command settings that can be changed in this way. See each command for
information on respective acceptable “data” values.
Command
Syntax
Audio Volume
BVdata
Automatic Shutoff
EZdata
Backlight Timeout
DFdata
Key Clicks
KCdata
Virtual Wedge Grid
AFdata
Virtual Wedge Postamble
AEdata
Virtual Wedge Preamble
ADdata
Note: See Appendix A, “Control Panel Applets” for more information about
the Virtual Wedge Postamble and Virtual Wedge Preamble commands.
Example 1
To change the Beep Volume to Off, you can send this string to the 700
Series Computer through the network: $+BV0
where:
$+
Indicates Change Configuration.
BV
Specifies the Audio Volume parameter.
Specifies a value of Off.
Example 2
To change the Beep Volume to Very Quiet and the Virtual Wedge Grid to
123: $+BV1AF123
where:
$+
Indicates Change Configuration
BV1
Specifies Audio Volume, set to Very Quiet (1)
AF123
Specifies Virtual Wedge Grid, set to a value of 123.
700 Series Color Mobile Computer User’s Manual
357
Appendix B — Unit Manager
Set Time and Date
This command sets the date and time on the 700 Series Computer. The
default date and time is June 1, 1999 at 12:00 AM.
From the network, send the following:
/+ yyyymmddhhmmss
where acceptable values for the date are:
yyyy
mm
dd
hh
mm
ss
0000-9999 Year
01-12
Month of the year
01-31
Day of the month
00-23
Hour
00-59
Minutes
00-59
Seconds
You can also set the time and date by using Configuration Management in
Unit Manager, or by using the Clock control panel applet in the Settings
menu. To access this control panel applet, tap Start → Settings → the
System tab → the Clock icon to access its control panel applet.
358
700 Series Color Mobile Computer User’s Manual
C
Bar Codes
This appendix contains a brief explanation of some of the bar code
symbologies that the 700 Series Color (700C) Mobile Computer decodes
and explains some of the general characteristics and uses of these bar code
types. It also includes several bar code labels that can be scanned into your
700 Series Computer.
700 Series Color Mobile Computer User’s Manual
359
Appendix C — Bar Codes
Bar Code Symbologies
Specific bar code algorithms can be enabled using the setup menus or the
host computer. Once the computer correctly decodes a bar code, the computer encodes data with descriptive information about the symbol. Response time is improved by limiting the computer to the bar codes being
used.
Bar Code Data String Formats
Data Bar Code Type
Data Format
Data Length
UPC short (UPC-E)
nddddddc
EAN short (EAN-8)
fndddddc
UPC long (UPC-A)
nddddddddddc
12
EAN long (EAN-13)
fnddddddddddc
13
UPC short add-on 2
nddddddcaa
10
EAN short add-on 2
fndddddcaa
10
UPC long add-on 2
nddddddddddcaa
14
EAN long add-on 2
fnddddddddddcaa
15
UPC short add-on 5
nddddddcaaaaa
13
EAN short add-on 5
fndddddcaaaaa
13
UPC long add-on 5
nddddddddddcaaaaa
17
EAN long add-on 5
fnddddddddddcaaaaa
18
Interleaved 2 of 5
d......d
Scan device dependent
Standard 2 of 5
d......d
Scan device dependent
Plessey
d......dc
Scan device dependent
Codabar
sd....ds
Scan device dependent
Code 11
d......d
Scan device dependent
Code 39
d......d
Scan device dependent
Extended Code 39
d......d
Scan device dependent
Code 93
d......d
Scan device dependent
Code 128
d......d
Scan device dependent
Note: These bar code data definitions apply to the Data Format column in
the previous table
a Add-on code digits
c Check digits
d Bar code digits
f EAN flag 1 characters
n Number system digits
s Start and stop digits
If MOD 10 or MOD 11 check digits are enabled, the digit falls at the end
of a bar code data string. Each check digit enabled extends the bar code
data string length by one character.
360
700 Series Color Mobile Computer User’s Manual
Appendix C — Bar Codes
The 700 Series Computer recognizes eleven of the most widely used bar
code symbologies. With bar code symbologies, like languages, there are
many different types. A bar code symbology provides the required flexibility for a particular inventory tracking system.
A symbology may be for particular industries, such as food and beverage,
automotive, railroad, or aircraft. Some of these industries have established
their own bar code symbology because other symbologies did not meet
their needs.
Without going into great detail on the bar code structure, note that no two
products use the same bar code. Each product gets a unique bar code.
Industries that use a particular type of bar code symbology have formed
regulating committees or are members of national institutes that issue and
keep track of bar codes. This ensures that each organization that contributes to a particular industry conforms to its standard. Without some form
of governing body, bar coding would not work.
S UPC (Universal Product Code) with/without add-ons
S EAN (European Article Numbering Code) with/without add-ons
S Codabar
S C11 (Code 11)
S C39 (Code 39)
S C93 (Code 93)
S C128 (Code 128)
S I 2 of 5 (Interleaved 2 of 5 Code)
S S 2 of 5 (Standard 2 of 5)
S Plessey
S MSI (a variant of Plessey)
700 Series Color Mobile Computer User’s Manual
361
Appendix C — Bar Codes
UPC
The UPC (Universal Product Code) is the symbology used throughout the
grocery and retail industries. This bar code symbology contains two pieces
of numerical information encoded on the bar code, producer identification, and product identification information.
The UPC symbol is 12 characters long. The first character of the UPC
symbol is a number system character, such as “0” for grocery items and “3”
for drug- and health-related items.
The UPC symbology is for retail environments such as grocery stores, convenience stores, and general merchandise stores.
Some retail items are so small that a standard UPC bar code cannot fit on
the packaging. When this occurs there is a permitted shorter version of the
UPC symbology, referred to as UPC-E. UPC-E is six characters long (eight
including number system and check digit), approximately half the size of a
standard UPC bar code.
EAN
EAN (European Article Numbering) symbology is similar to UPC symbology, except that it contains 13 characters and uses the first two to identify
countries.
The EAN symbology is used in the retail environment throughout most of
Europe. Though similar to UPC symbology, these are not interchangeable.
Codabar
Codabar was for retail price-labeling systems. Today it is widely accepted
by libraries, medical industries, and photo finishing services.
Codabar is a discrete, self-checking code with each character represented
by a stand-alone group of four bars and three intervening spaces.
Four different start or stop characters get defined and designated “a”, “b”,
“c”, and “d”. These start and stop characters are constructed using one
wide bar and two wide spaces. A complete Codabar symbol begins with
one of the start or stop characters followed by some number of data characters and ending in one of the start or stop characters.
Any of the start or stop characters may be used on either end of the symbol. It is possible to use the 16 unique start or stop combinations to identify label type or other information.
Since Codabar is variable-length, discrete, and self-checking, it is a versatile
symbology. The width of space between characters is not critical and may
vary significantly within the same symbol. The character set consists of “0”
through “9”, “-”, “$”, “:”, “/”, “.”, and “+”.
The specific dimensions for bars and spaces in Codabar optimize performance of certain early printing and reading equipment. Codabar has 18
different dimensions for bar and space widths. So many different dimensions often result in labels printed out of specification and cause Codabar
printing equipment to be more expensive.
362
700 Series Color Mobile Computer User’s Manual
Appendix C — Bar Codes
Code 11
Code 11 satisfies the requirements for a very high density, discrete numeric
bar code. The name Code 11 derives from 11 different data characters that
can be represented, in addition to a start or stop character.
The character set includes the 10 digits and the dash symbol. Each character is represented by a stand-alone group of three bars and two intervening
spaces. Although Code 11 is discrete, it is not self-checking. A single printing defect can transpose one character into another valid character. One or
two check digits obtain data security.
The specifications for Code 11 suggest that this code should have a narrow
element width of 7.5 mils. This results in an information density of 15
characters per inch.
Code 39
Code 39 (C39) is the most widely used symbology among the industrial
bar codes. Most major companies, trade associations, and the federal government find this code to fit their needs. The main feature of this symbology is the ability to encode messages using the full alphanumeric character
set, seven special characters, and ASCII characters.
Programming for this symbology can be for any length that the application
requires. The application program for the 700 Series Computer handles
symbology at least one character but no more than 32 characters in length.
When programming the computer for Code 39, it is important to set the
symbology limit as close as possible (minimum and maximum bar code
lengths being scanned). Doing so keeps the computer bar code processing
time to a minimum and conserves battery power.
Bar code readers can respond to Uniform Symbology Specification symbols
in non-standard ways for particular applications. These methods are not
for general applications, because of the extra programming required. Code
39 Full ASCII is one example of non-standard code.
Note: See page 368 to scan several Code 39 bar code labels available to
change settings on your 700 Series Computer.
Encoded Code 39 (Concatenation)
If the first data character of a symbol is a space, the reader may be programmed to append the information contained in the remainder of the
symbol to a storage buffer. This operation continues for all successive symbols that contain a leading space, with messages being added to the end of
previously stored ones. When a message is read which does not contain a
leading space, the contents are appended to the buffer, the entire buffer is
transmitted, and the buffer is cleared.
Encoded Code 39 (Full ASCII)
If the bar code reader is programmed for the task, the entire ASCII character set (128 characters) could be coded using two character sequences: a
symbol (“$”,“.”,“%”,“/”) followed by a letter of the alphabet.
700 Series Color Mobile Computer User’s Manual
363
Appendix C — Bar Codes
Code 93
The introduction of Code 93 provided a higher density alphanumeric
symbology designed to supplement Code 39. The set of data characters in
Code 93 is identical with that offered with Code 39. Each character consists of nine modules arranged into three bars and three spaces.
Code 93 uses 48 of the 56 possible combinations. One of these characters,
represented by a square, is reserved for a start or stop character, four are
used for control characters, and the remaining 43 data characters coincide
with the Code 39 character set. An additional single module termination
bar after the stop character concludes the final space.
Code 93 is a variable length, continuous code that is not self-checking. Bar
and spaces widths may be one, two, three, or four modules wide. Its structure uses edge-to-similar-edge decoding. This makes the bar code immune
to uniform ink spread, which allows liberal bar width tolerances.
Code 93 uses two check characters. Its supporters believes this makes it the
highest density alphanumeric bar code. The dual check digit scheme provides for high data integrity. All substitution errors in a single character are
detected for any message length.
Code 128
Code 128 (C128) is one of the newest symbologies used by the retail and
manufacturing industries. It responds to the need for a compact alphanumeric bar code symbol that could encode complex product identification.
The fundamental requirement called for a symbology capable of being
printed by existing data processing printers (primarily dot-matrix printers)
that produce daily, work-in-progress, job, and product traceability documents. The ability to print identification messages between 10 and 32
characters long, on existing forms and labels deemed an important requirement.
Code 128 uniquely addresses this need as the most compact, complete,
alphanumeric symbology available.
Additionally, the Code 128 design with geometric features, improves scanner read performance, does self-checking, and provides data message management function codes.
Code 128 encodes the complete set of 128 ASCII characters without adding extra symbol elements. Code 128 contains a variable-length symbology and the ability to link one message to another for composite message
transmission. Code 128, being a double-density field, provides two numeric values in a single character.
Code 128 follows the general bar code format of start zone, data, check
digit, stop code, and quiet zone. An absolute minimum bar or space dimension of nine mils (0.010 inch minimum nominal ± 0.001 inch tolerance) must be maintained.
Characters in Code 128 consist of three bars and three spaces so that the
total character set includes three different start characters and a stop character.
364
700 Series Color Mobile Computer User’s Manual
Appendix C — Bar Codes
UCC/EAN-128 Shipping Container Labeling is a versatile tool that can
ease movement of products and information. The Shipping Container Labeling bar code can take any form and usually has meaning only within the
company or facility where applied.
Because this random data can get mistaken later for an industry standard
code format, the UCC and EAN chose a symbology uniquely identified
from these other bar codes. This standard is for maximum flexibility, to
handle the diversity of distribution in global markets by cost efficiency.
The UCC/EAN-128 Container Labeling specification calls for a FUNC1
to immediately follow the bar code’ s start character. FUNC1 also follows
any variable-length application field. The specification also calls for the
computer to send “]C1” for the first FUNC1. The specification requires
that the computer send a “” (hex 1D) for subsequent FUNC1 codes
in the bar code.
Because “” is not compatible with computer emulation data streams,
the Uniform Code Council has been asked to change the specification.
This change is made to send the same three character sequence “]C1” to
identify the embedded FUNC1 codes.
This implementation should provide for clean application coding by identifying the same sequences for the same scanned codes. If the communication of Norand bar code types is enabled, the Shipping Container Label
codes precede with a “J”. These strings will appear on the computer display. The application may have to allow for strings longer than 48 characters (maximum length indicated in the specification). Actual length variance depends on the number of variable-length data fields. Allowing for 60
characters should be sufficient. Within the Code 128 specification, the
computer can link bar codes together. If this is to happen, allow for more
characters (computer limit is 100 characters).
The Application Identifier Standard, that is part of the UCC/EAN Shipping Label concept, complements, rather than replaces, other UCC/EAN
standards. Most UCC/EAN standards primarily identify products.
Several industries expressed the need to standardize more than product
identification. The UCC/EAN Code 128 Application Identifier Standard
supplies this tool. The standard adds versatility for inter-enterprise exchanges of perishability dating, lot and batch identification, units of use
measure, location codes, and several other information attributes.
For more detailed information on Code 128 UCC/EAN Shipping Label
bar code and Application Identifier Standard, refer to the UCC/EAN-128
Application Identifier Standard specification.
700 Series Color Mobile Computer User’s Manual
365
Appendix C — Bar Codes
I 2 of 5 (Interleaved)
I 2 of 5 (Interleaved 2 of 5 Code) is an all-numeric symbology, widely used
for warehouse and heavy industrial applications. Its use has been particularly prevalent in the automobile industry. The I 2 of 5 symbology can be
placed on smaller labels than what the standard UPC symbology requires.
I 2 of 5 also provides a little more flexibility on the type of material it can
print on. Interleaved 2 of 5 Code has its name because of the way the bar
code is configured.
I 2 of 5 bars and spaces both carry information. The bars represent the
odd number position digits, while spaces represent the even number position digits. The two characters are interleaved as one. Messages encoded
with this symbology have to use an even number of characters since two
numeric characters always get interleaved together.
S 2 of 5 (Standard 2 of 5)
The code S 2 of 5 (Standard 2 of 5 Code) is designed primarily for:
S Warehouse inventory handling
S Identification of photo finishing envelopes
S Airline tickets
S Baggage and cargo handling
The code S 2 of 5 is simple and straightforward. All information is contained in the widths of the bars, with the spaces serving only to separate
the individual bars.
Bars can either be wide or narrow, and the wide bars are usually three
times the widths of the narrow bars. Spaces may be any reasonable width
but are typically equal to the narrow bars. Narrow bars are identified as
zero bits and wide bars as one bits.
Remember the code structure by associating the bar positions from left to
right with weighting factors 1, 2, 4, 7, and parity. Exceptions to this rule
are zero, start, and stop. This code is a discrete code, since the white spaces
between the characters are not part of the code. Because the white spaces
carry no information, their dimensions are not critical.
The S 2 of 5 code is self-checking, meaning a scanner passing through a
printing void would detect the proper ratio of wide bars to total bars.
When the scanner spots an error, a non-read will occur.
366
700 Series Color Mobile Computer User’s Manual
Appendix C — Bar Codes
Plessey
Plessey finds its origin in the pulse width modulated (PWM) code developed in England. It is widely used for shelf markings in grocery stores.
Pulse width modulated codes represent each bit of information by a bar
and space pair. A zero bit consists of a narrow bar followed by a wide
space, while a one bit consists of a wide bar followed by a narrow space. It
is mainly a numeric symbology (0-9) with six extra characters available for
assigning any symbol or letter desired.
Plessey codes are not self-checking and employ a variety of check characters. Plessey employs a polynomial-based Cyclic Redundancy Check
(CRC). For start and stop characters, Plessey employs a 1101 and previously used a 0101.
This symbology is very limited about what information can be encoded. It
is not considered for new applications.
MSI Code (Variant of Plessey)
In addition to Plessey characteristics, the MSI Code employs a Modulus
10 Check. For start and stop checks, MSI employs a single bit pair of 1 as
a start symbol and a single bit pair of 0 as a stop symbol. MSI reverses the
1-2-4-8 BCD pattern for bit pair weighting to 8-6-2-1.
700 Series Color Mobile Computer User’s Manual
367
Appendix C — Bar Codes
Bar Code Labels
You can change some settings on your 700 Series Computer by scanning
the following Code 39 bar code labels.
S You can use the Unit Manager application to set the Automatic Shutoff,
Volume, Backlight Timer, or Key Clicks parameters (starting on page
352).
S You can use the Unit Manager application or the Data Collection control panel to set the three Virtual Wedge parameters (starting on page
325).
Note: When you use a bar code creation utility to make a scannable bar
code label, the utility probably adds opening and closing asterisks automatically. Asterisks are included here for translation purposes.
Audio Volume
Note: The Audio Volume parameter information is on page 356.
Turn Audio Off
*$+BV0*
*$+BV0*
Set Audio Volume to very quiet
*$+BV1*
*$+VB1*
Set Audio Volume to quiet
*$+BV2*
*$+BV2*
Set Audio Volume to normal (default)
*$+BV3*
*$+BV3*
Set Audio Volume to loud
*$+BV4*
*$+BV4*
Set Audio Volume to very loud
*$+BV5*
*$+BV5*
368
700 Series Color Mobile Computer User’s Manual
Appendix C — Bar Codes
Automatic Shutoff
Note: The Automatic Shutoff parameter information is on page 355.
Set Automatic Shutoff to 1 minute
*$+EZ1*
*$+EZ1*
Set Automatic Shutoff to 2 minutes
*$+EZ2*
*$+EZ2*
Set Automatic Shutoff to 3 minutes (default)
*$+EZ3*
*$+EZ3*
Set Automatic Shutoff to 4 minutes
*$+EZ4*
*$+EZ4*
Set Automatic Shutoff to 5 minutes
*$+EZ5*
*$+EZ5*
Backlight Timeout
Note: The Backlight Timeout parameter information is on page 353.
Backlight Timeout 10 seconds
*$+DF10*
*$+DF10*
Backlight Timeout 30 seconds
*$+DF30*
*$+DF30*
Backlight Timeout 1 minute (default)
*$+DF60*
*$+DF60*
700 Series Color Mobile Computer User’s Manual
369
Appendix C — Bar Codes
Backlight Timeout 2 minutes
*$+DF120*
*$+DF120*
Backlight Timeout 3 minutes
*$+DF180*
*$+DF180*
Backlight Timeout 4 minutes
*$+DF240*
*$+DF240*
Backlight Timeout 5 minutes
*$+DF300*
*$+DF300*
Key Clicks
Note: The Key Clicks parameter information is on page 354.
Disable key clicks
*$+KC0*
*$+KC0*
Enable soft key clicks
*$+KC1*
*$+KC1*
Enable loud key clicks (default)
*$+KC2*
*$+KC2*
370
700 Series Color Mobile Computer User’s Manual
Appendix C — Bar Codes
Virtual Wedge Grid, Preamble, Postamble
The following parameters are user-configurable strings. Refer to a full
ASCII chart for more information.
Grid
For Virtual Wedge Grid, the first part of the bar code would be the following, which can include a string of up to 240 characters. Parameter information starts on page 328.
*$+AF
*$+AF
Preamble
For Virtual Wedge Preamble, the first part of the bar code would be below,
followed by a string of up to 31 characters (no ) and an asterisk.
Default is no characters. Parameter information is on page 326.
*$+AD
*$+AD
Postamble
For Virtual Wedge Postamble, the first part of the bar code would be below, followed by a string of up to 31 characters (no ) and an asterisk. Default is no characters. Parameter information is on page 327.
*$+AE
*$+AE
700 Series Color Mobile Computer User’s Manual
371
Appendix C — Bar Codes
372
700 Series Color Mobile Computer User’s Manual
I
Index
The Classes and Functions Index covers classes and functions for the 700 Series
Color Mobile Computer.
The General Index covers all topics. Those in italics are figures, those in bold are
tables.
The Files Index is to assist you in locating descriptions for device drivers, applications, utilities, batch files, or other files within this publication.
700 Series Color Mobile Computer User’s Manual
373
Index
Classes and Functions
add_registry_section, [AddReg]
flags, 244
registry_root_string, 244
value_name, 244
AddReg, [DefaultInstall], 240
[AddReg], add_registry_section
flags, 244
registry_root_string, 244
value_name, 244
AddWep(), 103
AppName, [CEStrings], 237
BuildMax, [CEDevice], 238
BuildMin, [CEDevice], 238
CancelReadImage, IImage, 226
CancelReadRequest
IADC, 152
IBarCodeReaderControl, 160
[CEDevice]
BuildMax, 238
BuildMin, 238
ProcessorType, 238
UnsupportedPlatforms, 238
VersionMax, 238
VersionMin, 238
CESelfRegister, [DefaultInstall], 240
CESetupDLL, [DefaultInstall], 240
CEShortcuts, [DefaultInstall], 240
[CEShortcuts], shortcut_list_section
shortcut_filename, 245
shortcut_type_flag, 245
target_file/path, 245
target_file_path, 245
CESignature
[SourceDiskNames], 240
[Version], 236
[CEStrings]
AppName, 237
InstallDir, 237
Close, IImage, 228
CloseHandle()
DTR printing, 134, 135
IrDA printing, 128
NPCP printing, 129, 130
ConfigureProfile(), 106
ControlLED, IBarCodeReaderControl, 161
Copyfiles, [DefaultInstall], 240
[CopyFiles], file_list_section
destination_filename, 243
flags, 243
source_filename, 243
create/delete ADC COM objects, 149
CreateEvent(), 283
374
CreateFile()
DTR printing, 134, 135
IrDA printing, 128
NPCP printing, 129, 130
[DefaultInstall]
AddReg, 240
CESelfRegister, 240
CESetupDLL, 240
CEShortcuts, 240
Copyfiles, 240
DeregisterDevice(), 129
DTR printing, 134
[DestinationDirs], file_list_section, 242
DeviceIOControl(), 98
DTR printing, 134
NPCP printing, 129
DeviceIoControl(), NPCP printing, 130, 131
disk_ordinal, [SourceDiskNames], 240
DllRegisterServer, 240
DllUnregisterServer, 240
EnableWep(), 105
EncryptWepKeyForRegistry(), 106
file_list_section
[CopyFiles]
destination_filename, 243
flags, 243
source_filename, 243
[DestinationDirs], 242
filename, [SourceDiskFiles], 241
GetAssociationStatus(), 104
GetAuthenticationMode(), 104
GetBSSID(), 101
GetCodabar, IS9CConfig, 173
GetCode11, IS9CConfig2, 205
GetCode128, IS9CConfig, 180
GetCode39, IS9CConfig, 176, 200
GetCode93, IS9CConfig, 179
GetConfig, ISCP, 217
GetCustomSymIds, IS9CConfig2, 207
GetGlobalAmble, IS9CConfig2, 211
GetI2of5, IS9CConfig, 183
GetLinkSpeed(), 102
GetMac(), 101
GetMatrix2of5, IS9CConfig, 185
GetMSI, IS9CConfig, 187
GetNetworkMode(), 103
GetNetworkType(), 102
GetPDF417, IS9CConfig, 188
GetPDF417Ext, IS9CConfig2, 213
GetPlessey, IS9CConfig, 192
GetPowerMode(), 105
GetRSSI(), 103
GetRTSThreshold(), 106
GetSSID(), 101
700 Series Color Mobile Computer User’s Manual
Index
GetStandard2of5, IS9CConfig, 194
GetSymIdXmit, IS9CConfig2, 214
GetTelepen, IS9CConfig, 197
GetTXPower(), 102
GetUpcEan, IS9CConfig, 198
GetWepStatus(), 104
IADC, 151
CancelReadRequest, 152
Initialize, 153
QueryAttribute, 154
QueryData, 155
Read, 156
SetAttribute, 157
IBARCODEREADER.H, IBarCodeReaderControl functions, 159
IBarCodeReaderControl, 159
CancelReadRequest, 160
ControlLED, 161
Initialize, 162
IssueBeep, 163
QueryAttribute, 164
Read, 165
SetAttribute, 167
TriggerScanner, 171
IImage
CancelReadImage, 226
Close, 228
Open, 227
ReadImage, 225
ReadSigCapBuffer, 221
ReadSigCapFile, 224
Start, 226
Stop, 227
Imager, settings, IS9CConfig3, 216
Initialize
IADC, 153
IBarCodeReaderControl, 162
InstallDir, [CEStrings], 237
IS9CConfig, 172
GetCodabar, 173
GetCode128, 180
GetCode39, 176, 200
GetCode93, 179
GetI2of5, 183
GetMatrix2of5, 185
GetMSI, 187
GetPDF417, 188
GetPlessey, 192
GetStandard2of5, 194
GetTelepen, 197
GetUpcEan, 198
SetCodabar, 174
SetCode128, 181
SetCode39, 177
SetCode93, 179
SetI2of5, 184
SetMatrix2of5, 186
700 Series Color Mobile Computer User’s Manual
SetMSI, 187
SetPDF417, 189
SetPlessey, 192
SetStandard2of5, 195
SetTelepen, 197
IS9CConfig2, 204
GetCode11, 205
GetCustomSymIds, 207
GetGlobalAmble, 211
GetPDF417Ext, 213
GetSymIdXmit, 214
SetCode11, 205
SetCustomSymIds, 208
SetGlobalAmble, 212
SetPDF417Ext, 213
SetSymIdXmit, 214
IS9CConfig3, 216
ISCP
GetConfig, 217
SetConfig, 218
isOrinoco(), 106
IssueBeep, IBarCodeReaderControl, 163
ITCDeviceClose, 150
ITCDeviceOpen, 140, 149
ITCUUID.LIB, IBarCodeReaderControl functions, 159
KernelIoControl(), 264
Open, IImage, 227
OSVERSIONINFO.dwBuildNumber, 238
OSVERSIONINFO.dwVersionMajor, 238
OSVERSIONINFO.dwVersionMinor, 238
ProcessorType, [CEDevice], 238
Provider, [Version], 236
QueryAttribute
IADC, 154
IBarCodeReaderControl, 164
QueryData, IADC, 155
RadioConnect(), 101
RadioDisconnect(), 101
Read, 140
IADC, 156
IBarCodeReaderControl, 165
ReadFile(), NPCP printing, 129
ReadImage, IImage, 225
ReadSigCapBuffer, IImage, 221
ReadSigCapFile, IImage, 224
RegFlushKey(), 81, 262, 270
RegisterDevice(), 129
DTR printing, 134
RegOpenKeyEx(), 282
RegQueryValueEx(), 282
RegSetValueEx(), 282
375
Index
SetAttribute
IADC, 157
IBarCodeReaderControl, 167
SetAuthenticationMode(), 104
SetChannel(), 105
SetCodabar, IS9CConfig, 174
SetCode11, IS9CConfig2, 205
SetCode128, IS9CConfig, 181
SetCode39, IS9CConfig, 177
SetCode93, IS9CConfig, 179
SetConfig, ISCP, 218
SetCustomSymIds, IS9CConfig2, 208
SetGlobalAmble, IS9CConfig2, 212
SetI2of5, IS9CConfig, 184
SetMatrix2of5, IS9CConfig, 186
SetMSI, IS9CConfig, 187
SetNetworkMode(), 103
SetPDF417, IS9CConfig, 189
SetPDF417Ext, IS9CConfig2, 213
SetPlessey, IS9CConfig, 192
SetRTSThreshold(), 106
SetSSID(), 105
SetStandard2of5, IS9CConfig, 195
SetSymIdXmit, IS9CConfig2, 214
SetTelepen, IS9CConfig, 197
SHFullScreen(), 262, 263
shortcut_list_section, [CEShortcuts]
shortcut_filename, 245
shortcut_type_flag, 245
target_file/path, 245
target_file_path, 245
376
Signature, [Version], 236
[SourceDiskFiles], filename, 241
[SourceDiskNames]
CESignature, 240
disk_ordinal, 240
SourceDisksNames.MIPS, 241
SourceDisksNames.SH3, 241
Start, IImage, 226
StartScanList(), 107
Stop, IImage, 227
string_key, [Strings], 237
[Strings], string_key, 237
SYSTEMINFO.dwProcessorType, 238
Trigger settings, IS9CConfig3, 216
TriggerScanner, IBarCodeReaderControl, 171
UnsupportedPlatforms, [CEDevice], 238
[Version]
CESignature, 236
Provider, 236
Signature, 236
VersionMax, [CEDevice], 238
VersionMin, [CEDevice], 238
WriteFile()
DTR printing, 134, 135
IrDA printing, 128
NPCP printing, 129, 130
700 Series Color Mobile Computer User’s Manual
Index
General Index
Numbers
1470 Imager. See Imager
1551/1553 Tethered Scanner. See Tethered scanner
1D laser scanner, about, 137
2D Imager
about, 137
data collection features, 146
aimer LED, 146
scaled illumination LED, 146
window size and position, 146
image acquisition features, 147
overview, 146
4820 printer, NPCP driver, 129
6804DM printer
DTR driver, 134
IrDA driver, 128
6804T printer
DTR driver, 134
IrDA driver, 128
6805A printer
DTR driver, 134
IrDA driver, 128
6806 printer
DTR driver, 134
IrDA driver, 128
6808 printer
DTR driver, 134
IrDA driver, 128
printer support, 127
681T printer, DTR driver, 134
6820 printer
IrDA driver, 128
NPCP driver, 129
printer support, 127
6920 Communications Server, ManifestName parameter,
254
700 Platform Build, version number, 342
740 Color Computer, 281
781 printers
DTR driver, 134
printer support, 127
782T printer, printer support, 127
802.11 CR radio CORE module, 107
802.11 WEP Encryption, profile security information, 91
802.11b
antenna color code, 85
API, 100
channel, 89
communications setup, 87
configuration profiles, 100
CORE module, 107
network type, 89
profiles, 87
basic information, 89
certificates, 95
exporting, 96
700 Series Color Mobile Computer User’s Manual
import/export, 96
importing, 97
read-only, 94
scan list, 97, 98
security information, 90
selected, 97
SSID (network name), 89
WEP encryption, 91
802.1x TLS, profile security information, 92
802.1x TTLS, profile security information, 93
Abstract Syntax Notation.1. See ASN.1
ActiveSync
ActiveSync Help, 30
adding programs, 26
adding programs to Start menu, 28
Folder behavior connected to e-mail server, 46
installing applications, 77
Microsoft Reader, 58
Pocket Internet Explorer
favorite links, 62
Mobile Favorites folder, 62
Pocket PC, 29
Pocket PC icon, 13
Pocket PC status icons, 12
URL, 29
ActiveX control tools, unit information control panel, CAB
files, 345
AD command, with/without data, 326
ADC COM interfaces, 138
functions
create/delete objects, 149
IADC, 151
IBarCodeReaderControl, 159
IS9CConfig, 172
IS9CConfig2, 204
IS9CConfig3, 216
Adding a profile, 88
Adding bookmarks, Microsoft Reader, 61
Adding drawings to text, Microsoft Reader, 61
Adding programs
ActiveSync, 26
Pocket Internet Explorer, 27
Pocket PC, 26
to the Start menu, 28
via ActiveSync, 28
via File Explorer, 28
Adjusting settings, Pocket PC, 26
Adobe Acrobat Reader, URL, 116
AE command, with/without data, 327
Aimer LED duration, configuration parameter, 323
Alpha plane on keypad, 281
Annotations index, Microsoft Reader, 61
Antenna, radio type, 85
APIs
802.11b, 100
AT command interface, 115
IrSock, 128
Appointments, via Calendar, 31
377
Index
APS linear imager, about, 137
ASCII
printing, 128
printing to a port, port print method, 128
raw text to printer, 128
ASN.1, 125
Asset management, DeviceURL parameter, 253
AT command interface, 115
terminal application, 114
testing, 117
Attaching notes to text, Microsoft Reader, 61
Audio files, Windows Media Player, 57
Audio system
external headset jack, 2
internal microphone, 2
speaker, 2
AutoCab, command line syntax, 82
AutoFTP, 260
AutoIP, 122
Automatic Data Collection. See ADC COM interfaces
Automatic Private IP. See AutoIP
Automatic shutoff
bar code configuration, 369
configuration parameter, 355
Autostart FTP, 260
AvantGo channels, Pocket Internet Explorer, 64
AXCommunication, 345
AXFileTransfer, 345
AXReaderCommand, 345
AXVWedge, 345
Backlight timeout
bar code configuration, 369
configuration parameter, 353
Bar Code
scanning labels, 368
supported symbologies, 147, 289
symbologies, 360
Codabar, 362
Code 11, 363
Code 128, 364
Code 39, 363
Code 39 concatenation, 363
Code 39 full ASCII, 363
Code 93, 364
data string formats, 360
EAN, 362
I 2 of 5, 366
MSI code, 367
Plessey, 367
S 2 of 5, 366
UPC, 362
Bar code configuration
audio volume, 368
automatic shutoff, 369
378
backlight timeout, 369
Code 39, 368
key clicks, 370
BARCODE_DATA_TYPE_ASCII, IBarCodeReaderControl::Read, 165
BARCODE_DATA_TYPE_UNICODE, IBarCodeReaderControl::Read, 165
BARCODE_DATA_TYPE_UNKNOWN, IBarCodeReaderControl::Read, 165
Battery
low battery conditions, 3
Pocket PC status icons, 12
status, 2
Battery status, unit information control panel applet, 343
Beeper
configuration parameter
frequency, 320
volume, 318
silencing the volume, 319
supported functions, 317
Unit Manager, 349
when not available
beeper frequency, 320
good read beep duration, 322
good read beeps, 321
biActualImageSize, pImgBuffer, IImage::ReadSigCapBuffer,
222
biBitCount, pImgBuffer, IImage::ReadSigCapBuffer, 222
biHeight, pImgBuffer, IImage::ReadSigCapBuffer, 222
biMaxImageBytes, pImgBuffer, IImage::ReadSigCapBuffer,
222
biWidth, pImgBuffer, IImage::ReadSigCapBuffer, 222
Block recognizer, Pocket PC input panel, 17
BlockSize, FTP Server, 252
Bluealps CORE module, 120
Bluetooth
CORE module, 120
unit information control panel, main stack CAB file,
344
Bluetooth compatibility, network support, 120
Bluetooth Device Manager, documentation, 120
Books, Microsoft Reader
adding bookmarks, 61
adding drawings, 61
annotations index, 61
attaching notes, 61
copying, 61
downloading, 58
highlighting, 61
reading, 60
removing, 61
searching, 61
Browing the Internet, Pocket Internet Explorer, 66
BTctrl program, documentation, 120
Build information, 5
byFNC1, IS9CConfig::SetCode128, 181
700 Series Color Mobile Computer User’s Manual
Index
CAB files
after the extraction, 248
creating, 236
INF files, 236
with CAB Wizard, 249
information regarding, 4
installation functions, SETUP.DLL, 248
placing files onto storage card, 80
unit information control panel applet, 344
Cabinet Wizard
creating CAB files, 249
troubleshooting, 250
using the application, 236
Cabling, scanner, 232
Calendar
creating
an appointment, 32
meeting requests, 33
Pocket Outlook, 31
Pocket PC icon, 13
scheduling a meeting, 33
using the summary screen, 33
Capacitor, internal super, 3
Capturing thoughts and ideas, via Notes, 40
Card support
CompactFlash cards, 5
modems, 4
MultiMediaCards, 5
radios, 4
SecureDigital cards, 5
CDMA/1xRTT, 110
antenna color code, 85
AT command set, 116
CORE module, 111
CEImager
location of the executable file, 80
migrating AUTORUN.DAT files, 80
Channel, 802.11 radio module, 89
ClassID field values
VN_CLASS_ASIC, 266
VN_CLASS_BOOTSTRAP, 266
VN_CLASS_KBD, 266
Clock
Pocket PC settings, 26
setting date and time, 358
Closing drivers, NPCP, 130
CMIP, 123
Codabar, 362
configuration parameter, 292
user ID, 310
default S9C settings, 175
enumerations, 175
IS9CConfig::GetCodabar, 173
IS9CConfig::SetCodabar, 174
modifier characters, 219
Code 11, 363
configuration parameter, 306
user ID, 314
700 Series Color Mobile Computer User’s Manual
default S9C settings, 206
enumerations, 206
IS9CConfig2::GetCode11, 205
IS9CConfig2::SetCode11, 205
modifier characters, 219
Code 128, 364
configuration parameter, 295
FNC1 character, 297
user ID, 310
default S9C settings, 181
enumerations, 182
IImage::ReadSigCapBuffer, 223
IImage::ReadSigCapFile, 224
IS9CConfig::GetCode128, 180
IS9CConfig::SetCode128, 181
modifier characters, 219
Code 39, 363
configuration parameter, 290
user ID, 310
default S9C settings, 177
enumerations, 178
IImage::ReadSigCapBuffer, 223
IImage::ReadSigCapFile, 224
IS9CConfig::GetCode39, 176
IS9CConfig::SetCode39, 177
modifier characters, 219
Code 93, 364
configuration parameter, 294
length, 294
user ID, 311
default S9C settings, 179
enumerations, 180
IS9CConfig::GetCode93, 179
IS9CConfig::SetCode93, 179
modifier characters, 219
Code Division Multiple Access. See CDMA/1xRTT
Codes
11, 363
128, 364
39, 363
39 concatenation, 363
39 full ASCII, 363
93, 364
Cold boot, IOCTL_HAL_COLDBOOT, 275
COM port
configuration, 231
wedge settings, 231
COM1, NPCP parameter, 129
COM1 port, 128
Comm port wedge
disabling, 231
enabling, 230
error messages, 232
limitations, 233
settings, 231
unit information control panel, 344
Command line syntax, AutoCab, 82
Common Object Resource Environment. See CORE
379
Index
Communications
DTR, 135
NPCP, 132
Communications options, 83
CompactFlash cards
card support, 5
installing applications, 78
Composing Messages, via Inbox, 45
Computer shutdown, 3
Concatenation, 363
Configuration Management. See Unit Manager
Configuration parameters
aimer LED duration, 323
automatic shutoff, 355
backlight timeout, 353
beeper
frequency, 320
volume, 318
codabar, 292
user ID, 310
code 11, 306
user ID, 314
code 128, 295
FNC1 character, 297
user ID, 310
code 39, 290
user ID, 310
code 93, 294
length, 294
user ID, 311
data matrix, 308
date/time, 352
EAN
13 user ID, 313
8 user ID, 313
good read
beep duration, 322
beeps, 321
identification
contact, 338
location, 340
name, 339
image dimension, 324
interleaved 2 of 5, 303
user ID, 311
key clicks, 354
macro PDF, 300
matrix 2 of 5, 304
user ID, 313
micro PDF 417, 302
MSI, 299
user ID, 311
PDF 417, 300
user ID, 311
plessey, 298
user ID, 312
prefix, 315
QR code, 307
380
security
encryption key, 335
read encryption, 333
read-only community string, 331
read/write community string, 332
write encryption, 334
SNMP, security subnet mask, 309
standard 2 of 5, 291
user ID, 312
suffix, 316
telepen, 305
user ID, 313
trap
authentication, 336
threshold, 337
UPC
A user ID, 312
E user ID, 312
UPC/EAN, 293
virtual wedge, 325
code page, 329
grid, 328
postamble, 327
preamble, 326
volume, 356
Connecting directly to e-mail server, via Inbox, 42
Connecting to
an ISP, 68
e-mail server, 72
work, 70
Connections
See also Getting connected
directly to e-mail server, 72
ending, 72
setting up an e-mail service, 73
status icon, 12
to an ISP, 68
via Ethernet, 69
via modem, 68
to work, 70
via Ethernet, 71
via modem, 70
via Ethernet
to an ISP, 69
to work, 71
via modem
to an ISP, 68
to work, 70
Contacts
creating a contact, 34
finding a contact, 35
MSN Messenger
chatting with, 55
working with, 54
Pocket Outlook, 34
Pocket PC icon, 13
using the summary screen, 36
700 Series Color Mobile Computer User’s Manual
Index
Control panel applets
clock, 358
data collection, 288
beeper/LED, 317
imager, 323
symbologies, 289
symbology options, 309
virtual wedge, 325
power, battery status, 2
SNMP, 330
identification, 338
security, 331
traps, 336
system, wireless network, 87
unit information, 341
battery status, 3, 343
CAB files, 344
versions, 6, 342
utilities, 81
Converting writing to text, 20
Copying text, Microsoft Reader, 61
CORE, 84
802.11b radio module, 107
details, 109
general, 107
accessing from
Programs panel, 84
Today screen, 84
Bluealps module, 120
Bluetooth, 120
module for 802.11b NIC, 100
WAN radio module, 111
details, 113
general, 111
Creating
a modem connection
to an ISP, 68
to work, 70
an Ethernet connection
to an ISP, 69
to work, 71
appointment via Calendar, 32
CAB files, 236
with CAB Wizard, 249
contact via Contacts, 34
document via Pocket Word, 47
drawing via Notes, 22
INF files, 236
meeting requests, 33
note via Notes, 41
recording via Notes, 23
task via Tasks, 38
workbook via Pocket Excel, 52
Customer Support, xviii
Data collection
2D imager features, 146
ADC COM interfaces, 138
build version number, 342
700 Series Color Mobile Computer User’s Manual
configuration parameters
aimer LED duration, 323
beeper frequency, 320
beeper volume, 318
codabar, 292
codabar user ID, 310
code 11, 306
code 11 user ID, 314
code 128, 295
code 128 FNC1 character, 297
code 128 user ID, 310
code 39, 290
code 39 user ID, 310
code 93, 294
code 93 length, 294
code 93 user ID, 311
data matrix, 308
EAN-13 user ID, 313
EAN-8 user ID, 313
good read beep duration, 322
good read beeps, 321
image dimension, 324
interleaved 2 of 5, 303
interleaved 2 of 5 user ID, 311
macro PDF, 300
matrix 2 of 5, 304
matrix 2 of 5 user ID, 313
micro PDF 417, 302
MSI, 299
MSI user ID, 311
PDF 417, 300
PDF 417 user ID, 311
plessey, 298
plessey user ID, 312
prefix, 315
QR code, 307
standard 2 of 5, 291
standard 2 of 5 user ID, 312
suffix, 316
telepen, 305
telepen user ID, 313
UPC-E user ID, 312
UPC-A user ID, 312
UPC/EAN, 293
virtual wedge, 325
virtual wedge code page, 329
virtual wedge grid, 328
virtual wedge postamble, 327
virtual wedge preamble, 326
functions
create/delete ADC COM objects, 149
IADC, 151
IBarCodeReaderControl, 159
IS9CConfig, 172
IS9CConfig2, 204
IS9CConfig3, 216
initialization, 138
Unit Manager, 348
Data filtering, virtual wedge grid, 141
381
Index
Data Matrix
configuration parameter, 308
IS9CConfig3 function, 216
Date, setting, 358
Date/Time, configuration parameter, 352
Deleting a profile, 88
DeviceName, FTP Server, 253
DeviceURL, FTP Server, 253
DHCP, 122
Display full screen, 263
Docks, modem support, 4
DRAM, low battery shutdown, 3
Drawing mode, Pocket Word, 51
Drawing on the screen
See also Notes
Pocket Word, 51
Drivers
DTR
communications, 135
installing, 134
opening, 135
removing, 134
writing to, 135
NPCP
closing, 130
communications, 132
I/O controls, 131
installing, 129
opening, 130
reading from, 130
removing, 129
writing to, 130
O’ Neil. See DTR printing
DTR printing, 134
closing driver, 135
communications, 135
opening driver, 135
removing driver, 134
writing to driver, 135
dwAttrBufferSize
IBarCodeReaderControl::QueryAttribute, 164
IBarCodeReaderControl::SetAttribute, 169
dwBufferSize
IADC::QueryAttribute, 154
IS9CConfig2::GetGlobalAmble, 211
IS9CConfig2::SetGlobalAmble, 212
dwCommandBuffSize
ISCP::GetConfig, 217
ISCP::SetConfig, 218
dwDataBufferSize
IADC::Read, 156
IBarCodeReaderControl::Read, 165
dwLength
IS9CConfig::SetCode128, 181
IS9CConfig::SetCode39, 177
IS9CConfig::SetCode93, 179
IS9CConfig::SetMatrix2of5, 186
IS9CConfig::SetMSI, 187
IS9CConfig::SetPlessey, 192
382
dwMaxNumElement, IS9CConfig2::GetCustomSymIds,
207
dwNextMessageSize, IADC::QueryData, 155
dwNumberOfBeeps, IBarCodeReaderControl::IssueBeep,
163
dwNumBytes
IS9CConfig::SetCodabar, 174
IS9CConfig::SetI2of5, 184
IS9CConfig::SetStandard2of5, 195
dwNumElement, IS9CConfig2::SetCustomSymIds, 208
dwReplyBuffMaxSize
ISCP::GetConfig, 217
ISCP::SetConfig, 218
dwStructSize
pImgBuffer, IImage::ReadSigCapBuffer, 222
pSigCapSpec, IImage::ReadSigCapBuffer, 221
dwTimeout
IADC::Read, 156
IBarCodeReaderControl::Read, 166
IImage::ReadImage, 225
dwTotalBufferedBytes, IADC::QueryData, 155
E-mail server
getting connected, 72
setting up a service, 73
eAmbleId
IS9CConfig2::GetGlobalAmble, 211
IS9CConfig2::SetGlobalAmble, 212
EAN, 362
configuration parameter, 293
13 user ID, 313
8 user ID, 313
default S9C settings, 181, 201
enumerations, 201
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
modifier characters, 220
ean13Check
IS9CConfig::GetUpcEan, 199
IS9CConfig::SetUpcEan, 200
ean13Select
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
ean8Check
IS9CConfig::GetUpcEan, 199
IS9CConfig::SetUpcEan, 200
ean8Reencode
IS9CConfig::GetUpcEan, 199
IS9CConfig::SetUpcEan, 200
ean8Select
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
eAttr
IBarCodeReaderControl::QueryAttribute, 164
IBarCodeReaderControl::SetAttribute, 167
eAttribID
IADC::QueryAttribute, 154
IADC::SetAttribute, 157
700 Series Color Mobile Computer User’s Manual
Index
eCheck
IS9CConfig::SetCodabar, 174
IS9CConfig::SetI2of5, 184
IS9CConfig::SetMSI, 187
IS9CConfig::SetPlessey, 192
IS9CConfig::SetStandard2of5, 195
IS9CConfig2::SetCode11, 205
eCip128State, IS9CConfig::SetCode128, 181
eCLSI, IS9CConfig::SetCodabar, 174
eCode128, IS9CConfig2::SetPDF417Ext, 213
eDataType, IBarCodeReaderControl::Read, 165
eDecode
IS9CConfig::SetCodabar, 174
IS9CConfig::SetCode128, 181
IS9CConfig::SetCode39, 177
IS9CConfig::SetCode93, 179
IS9CConfig::SetI2of5, 184
IS9CConfig::SetMatrix2of5, 186
IS9CConfig::SetMSI, 187
IS9CConfig::SetPlessey, 192
IS9CConfig::SetStandard2of5, 195
IS9CConfig::SetTelepen, 197
IS9CConfig2::SetCode11, 205
IS9CConfig2::SetPDF417Ext, 213
eDepth, pSigCapSpec, IImage::ReadSigCapBuffer, 222
eDeviceFlags
IADC::Initialize, 153
IBarCodeReaderControl::Initialize, 162
ITCDeviceOpen, 149
Editing a profile, 88
Edition information, 8
eEan128Ident, IS9CConfig::SetCode128, 181
eFormat
IImage::ReadImage, 225
IS9CConfig::SetCode39, 177
IS9CConfig::SetStandard2of5, 195
IS9CConfig::SetTelepen, 197
pImgBuffer, IImage::ReadSigCapBuffer, 222
pSigCapSpec, IImage::ReadSigCapBuffer, 222
eLED, IBarCodeReaderControl::ControlLED, 161
eLengthId
IS9CConfig::SetCodabar, 174
IS9CConfig::SetI2of5, 184
IS9CConfig::SetStandard2of5, 195
eMacroPdf, IS9CConfig::SetPDF417, 189
Embedded modules, SB555, 110
Encoded Code 39
concatenation, 363
full ASCII, 363
Ending a connection, 72
Enumerations
Codabar, 175
Code 11, 206
Code 128, 182
Code 39, 178
Code 93, 180
Interleaved 2 of 5, 185
Matrix 2 of 5, 186
MSI, 188
PDF 417, 190
700 Series Color Mobile Computer User’s Manual
Plessey, 193
Standard 2 of 5, 196
Telepen, 198
UPC/EAN, 201
ePdf417Decode, IS9CConfig::SetPDF417, 189
ePdfAddressee, IS9CConfig::SetPDF417, 189
ePdfChecksum, IS9CConfig::SetPDF417, 189
ePdfControlHeader, IS9CConfig::SetPDF417, 189
ePdfFileName, IS9CConfig::SetPDF417, 189
ePdfFileSize, IS9CConfig::SetPDF417, 189
ePdfSegmentCount, IS9CConfig::SetPDF417, 189
ePdfSender, IS9CConfig::SetPDF417, 189
ePdfTimeStamp, IS9CConfig::SetPDF417, 189
Epson Escape Sequences, 128
Error messages
comm port wedge, 232
tethered scanner, 232
ERROR_INSUFFICIENT_BUFFER
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
ERROR_INVALID_PARAMETER
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
eSS
IS9CConfig::SetCodabar, 174
IS9CConfig::SetCode39, 177
eSSChars, IS9CConfig::SetCode39, 177
eSymbology, IBarCodeReaderControl::Read, 165
eSymIdXmit, IS9CConfig2::SetSymIdXmit, 214
Ethernet
communications setup, 86
creating a connection
to an ISP, 69
to work, 71
ETSI GSM 07.05 interface specifications, 115
ETSI GSM 07.07 interface specifications, 115
European Article Numbering code. See EAN
eVer, IS9CConfig2::SetCode11, 205
Excel. See Pocket Excel
Exporting a profile, 802.11 radio module, 96
Factory repair, xviii
Favorite links, Pocket Internet Explorer, 62
File Explorer
adding programs to Start menu, 28
Pocket PC, 25
removing programs, 28
File Transfer Protocol. See FTP
Filter expression values, virtual wedge grid, 142
Find feature, Pocket PC, 25
fLedOn, IBarCodeReaderControl::ControlLED, 161
FlushBufferedData
IADC::CancelReadRequest, 152
IBarCodeReaderControl::CancelReadRequest, 160
Folder behavior connected to e-mail server
ActiveSync, 46
IMAP4, 46
POP3, 46
SMS, 46
383
Index
FRAME_NOT_ACKED, 131
fScannerOn, IBarCodeReaderControl::TriggerScanner, 171
fSigCapEnable, IImage::Open, 227
FTP
client, 256
configurable parameters, 252
BlockSize, 252
DeviceName, 253
DeviceURL, 253
IDNATarget, 254
ManifestName, 254
PauseAtStartup, 255
Root, 255
FTPDCMDS subdirectory, 259
heartbeat, 256
RTC 959, 259
server, 256
installing applications, 78
server requests
CDUP, 256
CWD, 256
DELE, 256
HELP, 256
LIST, 256
MKD, 256
MODE, 256
NLST, 256
NOOP, 256
PASS, 256
PWD, 256
QUIT, 256
RETR, 256
RMD, 256
RNFR, 256
RNTO, 257
SITE, 257
SITE ATTRIB, 257
SITE BOOT, 258
SITE COPY, 258
SITE EXIT, 258
SITE HELP, 258
SITE KILL, 258
SITE LOG, 258
SITE PLIST, 258
SITE RUN, 258
SITE STATUS, 259
SITE TIMEOUT, 259
STOR, 257
SYST, 257
TYPE, 257
USER, 257
XCUP, 257
XCWD, 257
XMKD, 257
XPWD, 257
XRMD, 257
stopping server from application, 260
384
support, 256
web browsers, 259
FTPDCMDS subdirectory, FTP support, 259
Full screen display, 263
GDI approach, 128
General Packet Radio Service. See GSM/GPRS
Getting connected
directly to an e-mail server, 72
infrared (IR) port, 67
ISP, 67
Pocket PC, 67
setting up an e-mail service, 73
to an ISP, 68
creating a modem connection, 68
creating an Ethernet connection, 69
to work, 70
creating a modem connection, 70
creating an Ethernet connection, 71
transfer items using infrared, 67
Global services and support center, xviii
Gold plane on keypad, 281
Good read, configuration parameter
beep duration, 322
beeps, 321
Grid data
configuration parameter, 328
filtering, 141
GSM/GPRS, 110
antenna color code, 85
AT command set
GEM350X, 116
MC45, 116
CORE module, 111
HAL, verion of Pocket PC
IOCTL_HAL_GET_BOOTLOADER_VERINFO,
274
IOCTL_HAL_GET_OAL_VERINFO, 273
Header files
IADC.H, IADC functions, 151
IBARCODEREADER.H, IBarCodeReaderControl
functions, 159
IS9CCONFIG.H
IS9CConfig functions, 172
IS9CConfig2 functions, 204
ITCDEVMGMT.H, 149
Headset jack, external, 2
Highlighting text, Microsoft Reader, 61
Hotmail account, 53
I 2 of 5. See Interleaved 2 of 5
I/O controls, NPCP driver, 131
iAspectRatio, pSigCapSpec, IImage::ReadSigCapBuffer,
221
700 Series Color Mobile Computer User’s Manual
Index
ID field values
IOCTL_HAL_ITC_READ_PARM
ITC_NVPARM_80211_INSTALLED, 268
ITC_NVPARM_80211_RADIOTYPE, 268
ITC_NVPARM_ANTENNA_DIVERSIT Y, 267
ITC_NVPARM_BLUETOOTH_INSTALLED, 268
ITC_NVPARM_CONTRAST, 266
ITC_NVPARM_DISPLAY_TYPE, 266
ITC_NVPARM_ECN, 266
ITC_NVPARM_EDBG_SUBNET, 266
ITC_NVPARM_EDG_IP, 266
ITC_NVPARM_ETHERNET_ID, 265
ITC_NVPARM_INTERMEC_DATACOLLECTION_HW, 267
ITC_NVPARM_INTERMEC_DATACOLLECTION_SW, 267
ITC_NVPARM_INTERMEC_SOFTWARE_CONTENT, 267
ITC_NVPARM_LAN9000_INSTALLED, 269
ITC_NVPARM_MANF_DATE, 265
ITC_NVPARM_MCODE, 266
ITC_NVPARM_RTC_RESTORE, 267
ITC_NVPARM_SERIAL_NUM, 265
ITC_NVPARM_SERIAL2_INSTALLED, 269
ITC_NVPARM_SERVICE_DATE, 266
ITC_NVPARM_SIM_PROTECT_HW_INSTALLED, 269
ITC_NVPARM_SIM_PROTECT_SW_INSTALLED, 269
ITC_NVPARM_VERSION_NUMBER, 266
ITC_NVPARM_VIBRATE_INSTALLED, 269
ITC_NVPARM_WAN_FREQUENCY, 268
ITC_NVPARM_WAN_INSTALLED, 268
ITC_NVPARM_WAN_RADIOTYPE, 268
ITC_NVPARM_WAN_RI, 267
IOCTL_HAL_ITC_WRITE_SYSPARM
ITC_ DOCK_SWITCH, 270
ITC_ WAKEUP_MASK, 271
ITC_AMBIENT_FRONTLIGHT, 271
ITC_AMBIENT_KEYBOARD, 271
ITC_REGISTRY_LOCATION, 270
ITC_REGISTRY_SAVE_ENABLE, 270
Identification
configuration parameter
contact, 338
location, 340
name, 339
Unit Manager, 351
IDNA
DeviceName, 253
DeviceURL, 253
IDNATarget, 254
ManifestName, 254
IDNATarget, FTP Server, 254
iid, ITCDeviceOpen, 149
IImage interface, 221
700 Series Color Mobile Computer User’s Manual
Image, acquisition features, 147
Image dimension, configuration parameter, 324
Imager
beeper functions not available
beeper frequency, 320
good read beep duration, 322
good read beeps, 321
control panel appet, data collection, 323
data collection parameters
aimer LED duration, 323
data matrix, 308
image dimension, 324
QR code, 307
settings, 232
supported
beeper functions, 317
functions, 323
symbologies, 289
supported symbologies, 147
symbologies not available
CIP 128 French Pharmaceutical, 296
Code 11, 306
Code 128 FNC1 character, 297
EAN 128 ]C1, 296
Macro PDF, 300
Matrix 2 of 5, 304
Micro PDF 417, 302
Telepen, 305
symbology user IDs not available
Codabar, 310
Code 11, 314
Code 128, 310
Code 39, 310
Code 93, 311
EAN 13, 313
EAN 8, 313
Interleaved 2 of 5, 311
Matrix 2 of 5, 313
MSI, 311
PDF 417, 311
Plessey, 312
Standard 2 of 5, 312
Telepen, 313
UPC A, 312
UPC E, 312
Unit Manager, 350
IMAP4, Folder behavior connected to e-mail server, 46
Import libraries
ITCDEVMGMT.LIB, 149
ITCUUID.LIB
IADC functions, 151
IBarCodeReaderControl functions, 159
IS9CConfig functions, 172
IS9CConfig2 functions, 204
Importing a profile, 802.11 radio module, 97
385
Index
Inbox
composing messages, 45
connecting directly to e-mail server, 42
Folder behavior connected to e-mail server, 46
getting connected, 67
managing e-mail messages and folders, 46
Pocket Outlook, 42
Pocket PC icon, 13
synchronizing e-mail messages, 42
using a message list, 43
using My Text, 24
INF files, creating, 236
Infrared (IR) port
Pocket PC, 67
transfer items using, 67
receiving information, 67
sending information, 67
Input panel
block recognizer, 17
keyboard, 17
letter recognizer, 18
methods available, 16
Pocket PC, 14
Pocket Word, 49
selecting typed text, 18
transcriber, 18
word suggestions, 17
Installation, site, xviii
Installation functions, SETUP.DLL, 248
Installing applications
using a storage card, 78
using CompactFlash cards, 78
using SecureDigital cards, 79
with ActiveSync, 77
with Application Manager, 78
with FTP Server, 78
Installing drivers
DTR, 134
NPCP, 129
Instant messaging, 53
Pocket PC icon, 12
Intelliget Bar Code Unit
IImage::ReadSigCapBuffer, 223
IImage::ReadSigCapFile, 224
Interface specifications, ETSI GSM 07.0x, 115
Interleaved 2 of 5, 366
configuration parameter, 303
user ID, 311
default S9C settings, 184
enumerations, 185
IS9CConfig::GetI2of5, 183
IS9CConfig::SetI2of5, 184
modifier characters, 219
Intermec Device Network Announcement. See IDNA
Internet Explorer. See Pocket Internet Explorer
Internet explorer
Pocket PC 2002 edition, 8
software build version, 5
Internet Service Provider. See ISP
IOCTL_GET_CPU_ID, 280
386
IOCTL_HAL_COLDBOOT, 275, 280
IOCTL_HAL_GET_BOOT_DEVICE, 277
IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274
IOCTL_HAL_GET_DEVICE_INFO, 264
IOCTL_HAL_GET_DEVICEID, 272
IOCTL_HAL_GET_OAL_VERINFO, 273
IOCTL_HAL_GET_RESET_INFO, 276
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
IOCTL_HAL_REBOOT, 278, 280
IOCTL_HAL_WARMBOOT, 275, 280
IOCTL_LOAD_NDIS_MINIPORT, 98
IOCTL_NPCP_BIND, 131
IOCTL_NPCP_CANCEL, 131
IOCTL_NPCP_CLOSE, 131
IOCTL_NPCP_ERROR, 131
IOCTL_NPCP_FLUSH, 131
IOCTL_PROCESSOR_INFORMATION, 279
IOCTL_UNLOAD_NDIS_MINIPORT, 98
iOffsetX, pSigCapSpec, IImage::ReadSigCapBuffer, 221
iOffsetY, pSigCapSpec, IImage::ReadSigCapBuffer, 222
IrDA printing, 128
iResolution, pSigCapSpec, IImage::ReadSigCapBuffer, 222
IS9CConfig3
Data Matrix symbology, 216
imager settings, 216
QRCode symbology, 216
trigger settings, 216
ISP
connecting to via Pocket PC, 68
creating
a modem connection, 68
an Ethernet connection, 69
Pocket Internet Explorer, 62
Pocket PC, 67
ITC_ DOCK_SWITCH, 270
ITC_ WAKEUP_MASK, 271
ITC_AMBIENT_FRONTLIGHT, 271
ITC_AMBIENT_KEYBOARD, 271
ITC_BARCODE_LASER_GOOD_READ_LED, IBarCodeReaderControl::ControlLED, 161
ITC_DEVID_80211RADIO_INTEL_2011B, 268
ITC_DEVID_80211RADIO_MAX values
ITC_DEVID_80211RADIO_INTEL_2011B, 268
ITC_DEVID_80211RADIO_NONE, 268
ITC_DEVID_80211RADIO_NONE, 268
ITC_DEVID_INTERMEC2D_IMAGER, 267
ITC_DEVID_OEM2D_IMAGER, 267
ITC_DEVID_SCANHW_MAX values
ITC_DEVID_INTERMEC2D_IMAGER, 267
ITC_DEVID_OEM2D_IMAGER, 267
ITC_DEVID_SCANHW_NONE, 267
ITC_DEVID_SE900_LASER, 267
ITC_DEVID_SE900HS_LASER, 267
ITC_DEVID_SCANHW_NONE, 267
ITC_DEVID_SE900_LASER, 267
ITC_DEVID_SE900HS_LASER, 267
ITC_DEVID_WANRADIO_NONE, 268
ITC_DEVID_WANRADIO_SIEMENS_MC45, 268
ITC_DEVID_WANRADIO_SIERRA_SB555, 268
700 Series Color Mobile Computer User’s Manual
Index
ITC_DEVID_WANRADIO_XIRCOM_GEM3503, 268
ITC_DHATTR_READFILTER
IADC::SetAttribute, rgbData, 157
IBarCodeReaderControl::SetAttribute, 167
ITC_DHDEVFLAG_NODATA, ITCDeviceOpen, 149
ITC_DHDEVFLAG_READAHEAD
IADC::Initialize, 153
IBarCodeReaderControl::Initialize, 162
ITCDeviceOpen, 149
ITC_FILE_OPEN_E, IImage::ReadSigCapFile, 224
ITC_IFTP_STOP, 260
ITC_IMGBUFF_TOO_SMALL_E
IImage::ReadImage, 225
IImage::ReadSigCapBuffer, 223
ITC_INV_PARAMETER_E
IImage::ReadImage, 225
IImage::ReadSigCapBuffer, 223
IImage::ReadSigCapFile, 224
ITC_KEYBOARD_CHANGE, CreateEvent(), 283
ITC_MAXFILTER_CHARS, IBarCodeReaderControl::SetAttribute, 167
ITC_MULTICLIENT_ENABLE, IADC::SetAttribute
eAttribID, 157
rgbData, 157
ITC_NVPARM_80211_INSTALLED, 268
ITC_NVPARM_80211_RADIOTYPE, 268
ITC_NVPARM_ANTENNA_DIVERSIT Y, 267
ITC_NVPARM_BLUETOOTH_INSTALLED, 268
ITC_NVPARM_CONTRAST, 266
ITC_NVPARM_DISPLAY_TYPE, 266
ITC_NVPARM_ECN, 266
ITC_NVPARM_EDBG_SUBNET, 266
ITC_NVPARM_EDG_IP, 266
ITC_NVPARM_ETHERNET_ID, 265
ITC_NVPARM_INTERMEC_DATACOLLECTION_HW, 267
ITC_NVPARM_INTERMEC_DATACOLLECTION_SW, 267
ITC_NVPARM_INTERMEC_SOFTWARE_CONTENT, 267
ITC_NVPARM_LAN9000_INSTALLED, 269
ITC_NVPARM_MANF_DATE, 265
ITC_NVPARM_MCODE, 266
ITC_NVPARM_RTC_RESTORE, 267
ITC_NVPARM_SERIAL_NUM, 265
ITC_NVPARM_SERIAL2_INSTALLED, 269
ITC_NVPARM_SERVICE_DATE, 266
ITC_NVPARM_SIM_PROTECT_HW_INSTALLED,
269
ITC_NVPARM_SIM_PROTECT_SW_INSTALLED,
269
ITC_NVPARM_VERSION_NUMBER, 266
ITC_NVPARM_VIBRATE_INSTALLED, 269
ITC_NVPARM_WAN_FREQUENCY, 268
ITC_NVPARM_WAN_INSTALLED, 268
ITC_NVPARM_WAN_RADIOTYPE, 268
700 Series Color Mobile Computer User’s Manual
ITC_NVPARM_WAN_RI, 267
ITC_RDRATTR_GOOD_READ_BEEP_DURATION,
IBarCodeReaderControl::SetAttribute, 167
ITC_RDRATTR_GOOD_READ_BEEPS_NUMBER,
IBarCodeReaderControl::SetAttribute, 167
ITC_RDRATTR_GOOD_READ_LED_ENABLE, IBarCodeReaderControl::SetAttribute, 167
ITC_RDRATTR_SCANNER_ENABLE, IBarCodeReaderControl::SetAttribute, 167
ITC_RDRATTR_TONE_ENABLE, IBarCodeReaderControl::SetAttribute, 167
ITC_RDRATTR_TONE_FREQUENCY, IBarCodeReaderControl::SetAttribute, 167
ITC_RDRATTR_VOLUME_LEVEL, IBarCodeReaderControl::SetAttribute, 167
ITC_REGISTRY_LOCATION, 270
ITC_REGISTRY_SAVE_ENABLE, 270
ITC_RESULT_ERR_BADREGION_E
IImage::ReadSigCapBuffer, 223
IImage::ReadSigCapFile, 224
ITC_RESULT_NO_BC_DECODED_E
IImage::ReadSigCapBuffer, 223
IImage::ReadSigCapFile, 224
ITC_TIMEOUT_E, IImage::ReadImage, 225
ITU-T interface specifications, 115
Keeping a to-do list, via Tasks, 37
KernelIoControl
IOCTL_GET_CPU_ID, 280
IOCTL_HAL_COLDBOOT, 275, 280
IOCTL_HAL_GET_BOOT_DEVICE, 277
IOCTL_HAL_GET_BOOTLOADER_VERINFO,
274
IOCTL_HAL_GET_DEVICE_INFO, 264
IOCTL_HAL_GET_DEVICEID, 272
IOCTL_HAL_GET_OAL_VERINFO, 273
IOCTL_HAL_GET_RESET_INFO, 276
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
IOCTL_HAL_REBOOT, 278, 280
IOCTL_HAL_WARMBOOT, 275, 280
IOCTL_PROCESSOR_INFORMATION, 279
Key clicks
bar code configuration, 370
configuration parameter, 354
Keyboard, Pocket PC input panel, 17
Keypad
advanced remapping, 283
change notification, 283
driver registry settings, 282
planes, 281
remapping, 281
sample registry keys, 284
Knowledge Central, xviii
387
Index
Laser scanner
configuration parameters, 286
data collection parameters
beeper frequency, 320
beeper volume, 318
codabar, 292
codabar user ID, 310
code 11, 306
code 11 user ID, 314
code 128, 295
code 128 FNC1 character, 297
code 128 user ID, 310
code 39, 290
code 39 user ID, 310
code 93, 294
code 93 length, 294
code 93 user ID, 311
EAN-13 user ID, 313
EAN-8 user ID, 313
good read beep duration, 322
good read beeps, 321
interleaved 2 of 5, 303
interleaved 2 of 5 user ID, 311
macro PDF, 300
matrix 2 of 5, 304
matrix 2 of 5 user ID, 313
micro PDF 417, 302
MSI, 299
MSI user ID, 311
PDF 417, 300
PDF 417 user ID, 311
plessey, 298
plessey user ID, 312
prefix, 315
standard 2 of 5, 291
standard 2 of 5 user ID, 312
suffix, 316
telepen, 305
telepen user ID, 313
UPC-E user ID, 312
UPC-A user ID, 312
UPC/EAN, 293
virtual wedge, 325
virtual wedge code page, 329
virtual wedge grid, 328
virtual wedge postamble, 327
virtual wedge preamble, 326
SNMP configuration parameters
identification contact, 338
identification location, 340
identification name, 339
security encryption key, 335
security read encryption, 333
security read-only community string, 331
security read/write community string, 332
388
security subnet mask, 309
security write encryption, 334
trap authentication, 336
trap threshold, 337
supported
beeper functions, 317
symbologies, 289
supported symbologies, 147
symbologies not available
data matrix, 308
Datamatrix, 307
LEAP, 802.1x profile, security information, 93
Letter recognizer, Pocket PC input panel, 18
Library, Microsoft Reader, 59
Line printing, 128
lpBytesReturned
IOCTL_GET_CPU_ID, 280
IOCTL_HAL_GET_BOOT_DEVICE, 277
IOCTL_HAL_GET_BOOTLOADER_VERINFO,
274
IOCTL_HAL_GET_DEVICE_INFO, 264
IOCTL_HAL_GET_DEVICEID, 272
IOCTL_HAL_GET_OAL_VERINFO, 273
IOCTL_HAL_GET_RESET_INFO, 276
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
IOCTL_PROCESSOR_INFORMATION, 279
lpInBuf
IOCTL_GET_CPU_ID, 280
IOCTL_HAL_COLDBOOT, 275
IOCTL_HAL_GET_BOOT_DEVICE, 277
IOCTL_HAL_GET_BOOTLOADER_VERINFO,
274
IOCTL_HAL_GET_DEVICE_INFO, 264
IOCTL_HAL_GET_DEVICEID, 272
IOCTL_HAL_GET_OAL_VERINFO, 273
IOCTL_HAL_GET_RESET_INFO, 276
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
IOCTL_HAL_REBOOT, 278
IOCTL_HAL_WARMBOOT, 275
IOCTL_PROCESSOR_INFORMATION, 279
lpInBufSize
IOCTL_GET_CPU_ID, 280
IOCTL_HAL_COLDBOOT, 275
IOCTL_HAL_GET_BOOT_DEVICE, 277
IOCTL_HAL_GET_BOOTLOADER_VERINFO,
274
IOCTL_HAL_GET_DEVICE_INFO, 264
IOCTL_HAL_GET_DEVICEID, 272
IOCTL_HAL_GET_OAL_VERINFO, 273
IOCTL_HAL_GET_RESET_INFO, 276
IOCTL_HAL_REBOOT, 278
IOCTL_HAL_WARMBOOT, 275
IOCTL_PROCESSOR_INFORMATION, 279
700 Series Color Mobile Computer User’s Manual
Index
lpOutBuf
IOCTL_GET_CPU_ID, 280
IOCTL_HAL_COLDBOOT, 275
IOCTL_HAL_GET_BOOT_DEVICE, 277
IOCTL_HAL_GET_BOOTLOADER_VERINFO,
274
IOCTL_HAL_GET_DEVICE_INFO, 264
IOCTL_HAL_GET_DEVICEID, 272
IOCTL_HAL_GET_OAL_VERINFO, 273
IOCTL_HAL_GET_RESET_INFO, 276
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
IOCTL_HAL_REBOOT, 278
IOCTL_HAL_WARMBOOT, 275
IOCTL_PROCESSOR_INFORMATION, 279
LPT9 printer device, 129
Macro PDF, configuration parameter, 300
Managing e-mail messages and folders, via Inbox, 46
ManifestName, FTP Server, 254
Matrix 2 of 5
configuration parameter, 304
user ID, 313
default S9C settings, 186
enumerations, 186
IS9CConfig::GetMatrix2of5, 185
IS9CConfig::SetMatrix2of5, 186
modifier characters, 219
Meetings, via Calendar, 31
Menus, Pocket PC settings, 26
MIBs
ASN.1, 125
files, 125
object identifier, 126
OIDs, 126
Micro PDF 417, configuration parameter, 302
Microphone, internal, 2
Microsoft Developer Network Library. See MSDN library
Microsoft Exchange e-mail account, 53
Microsoft Passport account, 53
Microsoft Reader
books
downloading, 58
reading, 60
removing, 61
features, 61
adding bookmarks, 61
adding drawings, 61
annotations index, 61
attaching notes, 61
copying text, 61
highlighting text, 61
searching for text, 61
Pocket PC, 58
using the library, 59
Microsoft Word. See Pocket Word
Migrating applications, 80
Mini-Landline modems, 4
Mobile Favorites folder, Pocket Internet Explorer, 62
700 Series Color Mobile Computer User’s Manual
Modems
card support, 4
creating a connection
to an ISP, 68
to work, 70
MP3 files, Windows Media Player, 57
MSDN library, 260
MSI, 367
configuration parameter, 299
user ID, 311
default S9C settings, 187
enumerations, 188
IS9CConfig::GetMSI, 187
IS9CConfig::SetMSI, 187
modifier characters, 219
MSN account, 53
MSN Messenger
about, 53
accounts
Hotmail, 53
Microsoft Exchange e-mail, 53
Microsoft Passport, 53
MSN, 53
contacts
chatting with, 55
working with, 54
Pocket PC icon, 13
setting up, 54
using My Text, 24
MultiMediaCards, card support, 5
nBufferSize, IADC::SetAttribute, 157
nDepth, IImage::ReadImage, 225
NDIS_NET_AUTO_UNKNOWN, GetNetworkMode(),
103
NDIS_NET_MODE_ESS, GetNetworkMode(), 103
NDIS_NET_MODE_IBSS, GetNetworkMode(), 103
NDIS_NET_MODE_UNKNOWN, GetNetworkMode(),
103
NDIS_NET_TYPE_DS, GetNetworkType(), 102
NDIS_NET_TYPE_FH, GetNetworkType(), 102
NDIS_NET_TYPE_UNDEFINED, GetNetworkType(),
102
NDIS_POWER_LEVEL_1, GetTXPower(), 102
NDIS_POWER_LEVEL_15, GetTXPower(), 102
NDIS_POWER_LEVEL_30, GetTXPower(), 102
NDIS_POWER_LEVEL_5, GetTXPower(), 102
NDIS_POWER_LEVEL_63, GetTXPower(), 102
NDIS_POWER_LEVEL_UNKNOWN, GetTXPower(),
102
NDIS_RADIO_ASSOCIATED, GetAssocationStatus(),
104
NDIS_RADIO_AUTH_MODE_AUTO, GetAuthenticationMode(), 104
NDIS_RADIO_AUTH_MODE_ERROR, GetAuthenticationMode(), 104
NDIS_RADIO_AUTH_MODE_OPEN, GetAuthenticationMode(), 104
389
Index
NDIS_RADIO_AUTH_MODE_SHARED, GetAuthenticationMode(), 104
NDIS_RADIO_POWER_MODE_CAM, GetPowerMode(), 105
NDIS_RADIO_POWER_MODE_MAX, GetPowerMode(), 105
NDIS_RADIO_POWER_MODE_PSP, GetPowerMode(),
105
NDIS_RADIO_POWER_UNKNOWN, GetPowerMode(), 105
NDIS_RADIO_SCANNING, GetAssociationStatus(), 104
NDIS_RADIO_WEP_ABSENT, GetWepStatus, 104
NDIS_RADIO_WEP_DISABLED, GetWepStatus(), 104
NDIS_RADIO_WEP_ENABLED, GetWepStatus(), 104
NDIS_RADIO_WEP_NOT_SUPPORTED, GetWepStatus(), 104
Network adapters
802.11b, 87
antenna color code, 85
Ethernet communications, 86
wireless printing, 120
WWAN radio options, 110
Network management. See SNMP
Network type, 802.11 radio module, 89
nFilterChars
IADC::SetAttribute, 157
IBarCodeReaderControl::SetAttribute, 167
nInBufSize
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
Notes
creating a note, 41
drawing on the screen, 22
creating a drawing, 22
selecting a drawing, 22
Pocket Outlook, 40
Pocket PC icon, 13
recording a message, 23
creating a recording, 23
writing on the screen, 19
alternate writing, 21
converting writing to text, 20
selecting the writing, 19
tips for good recognition, 21
nOutBufSize
IOCTL_GET_CPU_ID, 280
IOCTL_HAL_COLDBOOT, 275
IOCTL_HAL_GET_BOOT_DEVICE, 277
IOCTL_HAL_GET_BOOTLOADER_VERINFO,
274
IOCTL_HAL_GET_DEVICE_INFO, 264
IOCTL_HAL_GET_DEVICEID, 272
IOCTL_HAL_GET_OAL_VERINFO, 273
IOCTL_HAL_GET_RESET_INFO, 276
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
IOCTL_HAL_REBOOT, 278
390
IOCTL_HAL_WARMBOOT, 275
IOCTL_PROCESSOR_INFORMATION, 279
NPCP printing, 129
about, 129
closing driver, 130
COM1 parameters, 129
communications, 132
driver I/O controls, 131
installation, 129
LPT9, 129
opening driver, 130
reading from driver, 130
removal, 129
sample code, 132
unit information control panel, NPCPTEST CAB file,
344
writing to driver, 130
O’ Neil printing
See also DTR printer
installing driver, 134
Object store
IOCTL_HAL_COLDBOOT, 275
IOCTL_HAL_REBOOT, 278
IOCTL_HAL_WARMBOOT, 275
Oldstyle device ID, 272
Onsite repair, xviii
Opening drivers
DTR, 135
NPCP, 130
Operators, virtual wedge grid, 144
Other publications, xviii
Owner information, Pocket PC settings, 26
Page format printing, 128
Password
Pocket Excel, 53
Pocket PC settings, 26
PauseAtStartup, FTP Server, 255
pBarCodeDataDetails, IBarCodeReaderControl::Read, 165
pbyFNC1, IS9CConfig::GetCode128, 180
PDF 417
about the laser scanner, 137
configuration parameter, 300
user ID, 311
default S9C settings, 190
enumerations, 190
extensions
IS9CConfig2::GetPDF417ext, 213
IS9CConfig2::SetPDF417ext, 213
IImage::ReadSigCapBuffer, 223
IImage::ReadSigCapFile, 224
IS9CConfig::GetPDF417, 188
IS9CConfig::SetPDF417, 189
modifier characters, 220
pdwBufferSize, IS9CConfig2::GetGlobalAmble, 211
700 Series Color Mobile Computer User’s Manual
Index
pdwLength
IS9CConfig::GetCode128, 180
IS9CConfig::GetCode93, 179
IS9CConfig::GetMatrix2of5, 185
IS9CConfig::GetMSI, 187
IS9CConfig::GetPlessey, 192
pdwNumBytes
IS9CConfig::GetCodabar, 173
IS9CConfig::GetI2of5, 183
IS9CConfig::GetStandard2of5, 194
pdwNumElement, IS9CConfig2::GetCustomSymIds, 207
pdwReplyBuffSize
ISCP::GetConfig, 217
ISCP::SetConfig, 218
pdwTotalDiscardedBytes, IADC::CancelReadRequest, 152
peCheck
IS9CConfig::GetCodabar, 173
IS9CConfig::GetCode39, 176
IS9CConfig::GetI2of5, 183
IS9CConfig::GetMSI, 187
IS9CConfig::GetPlessey, 192
IS9CConfig::GetStandard2of5, 194
IS9CConfig2::GetCode11, 205
peCip128State, IS9CConfig::GetCode128, 180
peCLSI, IS9CConfig::GetCodabar, 173
peCode128, IS9CConfig2::GetPDF417Ext, 213
peDecode
IS9CConfig::GetCodabar, 173
IS9CConfig::GetCode128, 180
IS9CConfig::GetCode39, 176
IS9CConfig::GetCode93, 179
IS9CConfig::GetI2of5, 183
IS9CConfig::GetMatrix2of5, 185
IS9CConfig::GetMSI, 187
IS9CConfig::GetPlessey, 192
IS9CConfig::GetStandard2of5, 194
IS9CConfig::GetTelepen, 197
IS9CConfig2::GetCode11, 205
IS9CConfig2::GetPDF417Ext, 213
peEan128Ident, IS9CConfig::GetCode128, 180
peFormat
IS9CConfig::GetCode39, 176
IS9CConfig::GetStandard2of5, 194
IS9CConfig::GetTelepen, 197
peLengthId
IS9CConfig::GetCodabar, 173
IS9CConfig::GetI2of5, 183
IS9CConfig::GetStandard2of5, 194
peMacroPdf, IS9CConfig::GetPDF417, 188
700 Series Color Mobile Computer User’s Manual
pePdf417Decode, IS9CConfig::GetPDF417, 188
pePdfAddressee, IS9CConfig::GetPDF417, 189
pePdfChecksum, IS9CConfig::GetPDF417, 189
pePdfControlHeader, IS9CConfig::GetPDF417, 188
pePdfFileName, IS9CConfig::GetPDF417, 188
pePdfFileSize, IS9CConfig::GetPDF417, 189
pePdfSegmentCount, IS9CConfig::GetPDF417, 188
pePdfSender, IS9CConfig::GetPDF417, 189
pePdfTimeStamp, IS9CConfig::GetPDF417, 188
peSS
IS9CConfig::GetCodabar, 173
IS9CConfig::GetCode39, 176
peSSChars, IS9CConfig::GetCode39, 176
peSymIdXmit, IS9CConfig2::GetSymIdXmit, 214
peVer, IS9CConfig2::GetCode11, 205
pImgBuffer
IImage::ReadImage, 225
IImage::ReadSigCapBuffer, 222
Planes, keypad, 281
Plessey, 367
configuration parameter, 298
user ID, 312
default S9C settings, 193
enumerations, 193
IS9CConfig::GetPlessey, 192
IS9CConfig::SetPlessey, 192
modifier characters, 220
pnBufferData, IADC::QueryAttribute, 154
pnBytesReturned
IADC::Read, 156
IBarCodeReaderControl::Read, 165
Pocket Excel
about, 52
creating a workbook, 52
Pocket PC icon, 13
Pocket Internet Explorer
about, 62
adding programs, 27
AvantGo channels, 64
browing the Internet, 66
favorite links, 62
getting connected, 67
Mobile Favorites folder, 62
Pocket PC icon, 13
software build, 5
viewing mobile favorites and channels, 66
Pocket Outlook, 31
Calendar, 31
391
Index
Pocket PC
about, 8
ActiveSync, 29
basic skills, 11
Calendar, 31
command bar, 14
Contacts, 34
edition information, 8
getting connected, 67
Inbox, 42
input panel. See Input panel
IOCTL_HAL_GET_BOOTLOADER_VERINFO,
274
IOCTL_HAL_GET_OAL_VERINFO, 273
MSN Messenger, 53
navigation bar, 14
Notes, 40
notifications, 15
status icon, 12
Pocket Excel, 52
Pocket Word, 47
pop-up menus, 15
programs, 13
status icons, 12
support URLs, 10
Tasks, 37
Today screen, 11
where to find information, 10
Windows Media Player, 57
writing on the screen, 19
Pocket Word
about, 47
creating a document, 47
drawing mode, 51
Pocket PC icon, 13
recording mode, 51
tips, 53
typing mode, 49
writing mode, 50
POP3, Folder behavior connected to e-mail server, 46
Postamble
configuration parameter, 327
with/without data, 327
Power
control panel, battery status, 2
Pocket PC settings, 26
ppvObject
ITCDeviceClose, 150
ITCDeviceOpen, 149
Preamble
configuration parameter, 326
with/without data, 326
Prefix, configuration parameter, user ID, 315
Printer support, 128
IrDA printer driver, 128
NPCP printer driver, 129
392
O’ Neil printer driver, 134
Processor information, IOCTL_PROCESSOR_INFORMATION, 279
Profiles
802.11 radio module, 87
basic information, 89
certificates, 95
import/export, 96
read-only, 94
scan list, 97
security information, 90
adding to unit, 88
deleting, 88
editing, 88
Programs, adding or removing, Pocket PC, 26
pSigCapSpec
IImage::ReadSigCapBuffer, 221
IImage::ReadSigCapFile, 224
pStructSymIdPair
IS9CConfig2::GetCustomSymIds, 207
IS9CConfig2::SetCustomSymIds, 208
pSystemTime, IADC::Read, 156
pszDevice, ITCDeviceOpen, 149
pszDeviceName
IADC::Initialize, 153
IBarCodeReaderControl::Initialize, 162
pszFileName, IImage::ReadSigCapFile, 224
pwLength, IS9CConfig::GetCode39, 176
pwTotalDiscardedBytes, IBarCodeReaderControl::CancelReadRequest, 160
pwTotalDiscardedMessages
IADC::CancelReadRequest, 152
IBarCodeReaderControl::CancelReadRequest, 160
QR code
configuration parameter, 307
IS9CConfig3 function, 216
Quick Response code. See QR code
Radios
See also Network adapters
card support, 4
Reader commands, 357
configuration change, 357
date and time settings, 358
Reading from drivers, NPCP, 130
Reboot methods
IOCTL_HAL_COLDBOOT, 280
IOCTL_HAL_REBOOT, 280
IOCTL_HAL_WARMBOOT, 280
Record button, recording a message, 23
Recording a message
See also Notes
Pocket Word, 51
Recording mode, Pocket Word, 51
700 Series Color Mobile Computer User’s Manual
Index
Recovery CD
AutoCab method, 82
AutoRun system, 76
AUTOUSER.DAT file, 81
part numbers, xviii
RegFlushKey() API, 262
S9C upgrade, 345
updating the system software, 79
RegFlush utility, 81
Registry
FTP Server parameters, 252
keypad remapping, 282
sample view of key mapping, 284
save location, IOCTL_HAL_ITC_WRITE_SYSPARM,
270
writing to a storage card, 81
Registry settings
AutoCfg, 122
AutoFTP, 261
AutoInterval, 122
AutoIP/DHCP, 122
DhcpMaxRetry, 122
DhcpRetryDialogue, 122
EnableDHCP, 122
keypad driver, 282
keypad planes
alpha, 282
gold, 282
unshifted, 282
Related publications, xviii
Removeable card support, 5
Removing drivers
DTR, 134
NPCP, 129
Removing programs, Pocket PC, 26, 28
RFC 959, 259
rgbAttrBuffer
IBarCodeReaderControl::QueryAttribute, 164
IBarCodeReaderControl::SetAttribute, 168
rgbBuffer
IADC::QueryAttribute, 154
IS9CConfig2::GetGlobalAmble, 211
IS9CConfig2::SetGlobalAmble, 212
rgbCommandBuff
ISCP::GetConfig, 217
ISCP::SetConfig, 218
rgbData, IADC::SetAttribute, 157
rgbDataBuffer
IADC::Read, 156
IBarCodeReaderControl::Read, 165
rgBeepRequests, IBarCodeReaderControl::IssueBeep, 163
rgbImageData, pImgBuffer, IImage::ReadSigCapBuffer,
222
rgbLengthBuff
IS9CConfig::GetCodabar, 173
IS9CConfig::GetI2of5, 183
IS9CConfig::GetStandard2of5, 194
IS9CConfig::SetCodabar, 174
700 Series Color Mobile Computer User’s Manual
IS9CConfig::SetI2of5, 184
IS9CConfig::SetStandard2of5, 195
rgbReplyBuff
ISCP::GetConfig, 217
ISCP::SetConfig, 218
Root, FTP Server, 255
S 2 of 5. See Standard 2 of 5
S_DEVICE_CONTENTION_E, IImage::Open, 227
S_DEVICE_NOT_OPENED_E
IImage::CancelReadImage, 226
IImage::Close, 228
IImage::ReadImage, 225
IImage::ReadSigCapBuffer, 223
IImage::ReadSigCapFile, 224
IImage::Start, 226
IImage::Stop, 227
S_IMG_NOT_PRESENT_E
IImage::Open, 227
IImage::Stop, 227
S_OK
IImage::CancelReadImage, 226
IImage::Close, 228
IImage::Open, 227
IImage::ReadImage, 225
IImage::ReadSigCapBuffer, 223
IImage::ReadSigCapFile, 224
IImage::Start, 226
IImage::Stop, 227
S9C
initialization, 138
IS9CConfig functions, 172
IS9CConfig2 functions, 204
IS9CConfig3 functions, 216
unit information control panel, upgrade files, 345
version number, 342
Sabre 1551E or 1553
See also Tethered scanner
cabling, 232
settings, 232
Sample code, NPCP printing, 132
SB555 radio, 110
Scan list of profiles, 802.11 radio module, 98
Scanner, unit configuration parameters
automatic shutoff, 355
backlight timeout, 353
date/time, 352
key clicks, 354
volume, 356
Scanner cabling, 232
Scheduling appointments and meetings, via Calendar, 31
SDK, unit information control panel, 345
SDMMC Disk, 80
Searching for text, Microsoft Reader, 61
SecureDigital cards
card support, 5
installing applications, 78, 79
393
Index
Security
configuration parameter
encryption key, 335
read encryption, 333
read-only community string, 331
read/write community string, 332
subnet mask, 309
write encryption, 334
Unit Manager, 350
Selected profile, 802.11 radio module, 97
Selecting, drawing via Notes, 22
Sending and receiving messages, via Inbox, 42
Serial port, modem support, 4
Service contract status, xviii
Setting date and time, 358
Setting up an e-mail service, 73
SETUP.DLL, installation functions, 248
Signature capture
IImage interface, 221
IImage::CancelReadImage, 226
IImage::Close, 228
IImage::Open, 227
IImage::ReadImage, 225
IImage::ReadSigCapBuffer, 221
IImage::ReadSigCapFile, 224
IImage::Start, 226
IImage::Stop, 227
Simple Network Management Protocol. See SNMP
Site installations, xviii
Site surveys, xviii
SMS, Folder behavior connected to e-mail server, 46
SNMP, 125
about SNMP, 123
CMIP, 123
configuration parameters
identification contact, 338
identification location, 340
identification name, 339
security encryption key, 335
security read encryption, 333
security read-only community string, 331
security read/write community string, 332
security subnet mask, 309
security write encryption, 334
trap authentication, 336
trap threshold, 337
control primitives, 123
multiple retrievals, 124
retrieval, 124
Unit Manager, 350
using the protocol, 123
SNMP OIDs
aimer LED duration, 323
automatic shutoff, 355
backlight timeout, 353
beeper
frequency, 320
volume, 318
codabar, 292
user ID, 310
394
code 11, 306
user ID, 314
code 128, 295
FNC1 character, 297
user ID, 310
code 39, 290
user ID, 310
code 93, 294
length, 294
user ID, 311
data matrix, 308
date/time, 352
default S9C settings, 210
EAN
13 user ID, 313
8 user ID, 313
good read
beep duration, 322
beeps, 321
identification
contact, 338
location, 340
name, 339
image dimension, 324
interleaved 2 of 5, 303
user ID, 311
IS9CConfig2::GetCustomSymIds, 207
IS9CConfig2::GetSymIdXmit, 214
IS9CConfig2::SetCustomSymIds, 208
IS9CConfig2::SetSymIdXmit, 214
key clicks, 354
macro PDF, 300
matrix 2 of 5, 304
user ID, 313
micro PDF 417, 302
MSI, 299
user ID, 311
PDF 417, 300
user ID, 311
plessey, 298
user ID, 312
prefix, 315
QR code, 307
security
encryption key, 335
read encryption, 333
read-only community string, 331
read/write community string, 332
write encryption, 334
security subnet mask, 309
standard 2 of 5, 291
user ID, 312
suffix, 316
telepen, 305
user ID, 313
transmission option, 215
trap
authentication, 336
threshold, 337
700 Series Color Mobile Computer User’s Manual
Index
UPC
A user ID, 312
E user ID, 312
UPC/EAN, 293
virtual wedge, 325
code page, 329
grid, 328
postamble, 327
preamble, 326
volume, 356
Symbology ID defaults, 219
Software Developer’ s Kit. See SDK
Software Tools CD. See Tools CD
Software versions, 6, 342
700 Series Computer, 5
unit information control panel applet, 342, 344
Speaker, 2
SSID (network name), 802.11 radio module, 89
Standard 2 of 5, 366
configuration parameter, 291
user ID, 312
default S9C settings, 196
enumerations, 196
IS9CConfig::GetStandard2of5, 194
IS9CConfig::SetStandard2of5, 195
modifier characters, 220
Start Menu, adding programs, 28
via ActiveSync, 28
via File Explorer, 28
Status icons, Pocket PC, 12
Stream device driver
NPCPPORT.DLL, 129
ONEIL.DLL, 134
stTimeStamp, IBarCodeReaderControl::Read, 165
Suffix, configuration parameter, 316
Summary screen
Calendar, 33
Contacts, 36
Tasks, 39
Support
global services and support center, xviii
web, xviii
Symbologies, 360
scanning labels, 368
Unit Manager, 348
user IDs
Codabar, 310
Code 11, 314
Code 128, 310
Code 39, 310
Code 93, 311
EAN 13, 313
EAN 8, 313
Interleaved 2 of 5, 311
Matrix 2 of 5, 313
MSI, 311
PDF 417, 311
Plessey, 312
Standard 2 of 5, 312
Telepen, 313
700 Series Color Mobile Computer User’s Manual
UPC A, 312
UPC E, 312
when not available
imager, 298, 299, 300, 302, 304, 305, 306
laser scanner, 307, 308
Symbology ID, Unit Manager, 349
Synchronizing e-mail messages, via Inbox, 42
System status maintained, 4
szDest, EncryptWepKeyForRegistry(), 106
szFilter
IADC::SetAttribute, 157
IBarCodeReaderControl::SetAttribute, 167
szSource, EncrypWepKeyForRegistry(), 106
Tasks
creating a task, 38
Pocket Outlook, 37
Pocket PC icon, 13
using the summary screen, 39
TCP/IP client, DHCP server, 122
Technical support, xviii
Telepen
configuration parameter, 305
user ID, 313
default S9C settings, 197
enumerations, 198
IS9CConfig::GetTelepen, 197
IS9CConfig::SetTelepen, 197
modifier characters, 220
Telephone numbers, xviii
Testing AT commands, 117
Tethered scanner
capabilities, 233
disabling, 231
enabling, 231
error messages, 232
limitations, 233
settings, 231
Text messages, Pocket PC, 24
Time, setting, 358
Tips for working, Pocket Excel, 53
TLS, 802.1x profile, 92
Today, Pocket PC settings, 26
Today screen, Pocket PC, 11
Tools CD
base operating system files, 78
Bluetooth documentation, 120
CAB files, 4, 78, 344
CE Imager, 80
Comm Port Wedge CAB file, 344
management tools installed on desktop, 77
MIB files, 125
part number, xviii
sample NPCP code, 132
SRDEVMGMT.CAB file, 286
Unit Manager CAB file, 347
Wireless Printing Development Guide, 120
wireless printing sample, 345
wireless printing SDK, 120
395
Index
Tracking people, via Contacts, 34
Transcriber, Pocket PC input panel, 18
Transfer items using infrared
getting connected, 67
receiving information, 67
sending information, 67
Trap configuration parameters
authentication, 336
threshold, 337
Traps
control panel appet, SNMP, 336
Unit Manager, 351
Troubleshooting, CAB Wizard, 250
TTLS, 802.1x profile, 93
Typing mode, Pocket Word, 49
Typing on the screen, Pocket Word, 49
UDP
FTPDCE, 256
within SNMP, 123
UDP broadcasts, IDNATarget parameter, 254
uiHeight, pSigCapSpec, IImage::ReadSigCapBuffer, 222
uiWidth, pSigCapSpec, IImage::ReadSigCapBuffer, 222
Unit, configuration parameters
automatic shutoff, 355
backlight timeout, 353
date/time, 352
key clicks, 354
volume, 356
Unit information
battery status, 343
CAB files, 344
ActiveX control tools, 345
Bluetooth stack, 344
Comm Port Wedge, 344
NPCP printer, 344
S9C Upgrade, 345
SDK, 345
Unit Manager, 345
Unit Manager help, 345
Windows configuration, 345
wireless printing demo, 345
wireless printing sample, 345
versions, 6, 342
700 Platform Build, 342
DataCollection Build, 342
S9C, 342
Unit Manager
automatic shutoff, 355
backlight timeout, 353
data collection, 348
beeper/LED, 349
imager, 350
symbologies, 348
symbology ID, 349
virtual wedge, 350
date/time, 352
documentation, 347
key clicks, 354
396
reader commands, 357
changing configuration, 357
setting time and date, 358
SNMP, 350
identification, 351
security, 350
traps, 351
volume, 356
Unit manager
installing applications, 78
unit information control panel, 345
help files, 345
Universal Product Code. See UPC
Unshifted plane on keypad, 281
UPC, 362
configuration parameter, 293
A user ID, 312
E user ID, 312
default S9C settings, 201
enumerations, 201
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
modifier characters, 220
upcACheck
IS9CConfig::GetUpcEan, 199
IS9CConfig::SetUpcEan, 200
upcAddOn2
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
upcAddOn5
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
upcAddOnDigits
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
upcANumSystem
IS9CConfig::GetUpcEan, 199
IS9CConfig::SetUpcEan, 200
upcAReencode
IS9CConfig::GetUpcEan, 199
IS9CConfig::SetUpcEan, 200
upcASelect
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
upceanDecode
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
upcECheck
IS9CConfig::GetUpcEan, 199
IS9CConfig::SetUpcEan, 200
upcENumSystem
IS9CConfig::GetUpcEan, 199
IS9CConfig::SetUpcEan, 200
upcEReencode
IS9CConfig::GetUpcEan, 199
IS9CConfig::SetUpcEan, 200
upcESelect
IS9CConfig::GetUpcEan, 198
IS9CConfig::SetUpcEan, 200
Updating, bootloader, 77
700 Series Color Mobile Computer User’s Manual
Index
URLs
ActiveSync, 29
Adobe Acrobat Reader, 116
AT command interface
CDMA/1xRTT SB555, 116
GPRS/GSM GEM350X, 116
GPRS/GSM MC45, 116
customer support, xviii
full screen display, 263
Knowledge Central, xviii
MIBs, 125
Microsoft Exchange e-mail account, 53
Microsoft Passport account, 53
Microsoft support, 10
MSDN library, 260
Pocket PC, 10
Pocket PC support, 10
web support, xviii
User Datagram Protocol. See UDP
Using a message list, via Inbox, 43
UUID, 272
Video files, Windows Media Player, 57
Viewing mobile favorites and channels, Pocket Internet
Explorer, 66
Virtual wedge
bar code configuration
grid, 371
postamble, 371
preamble, 371
configuration parameter, 325
code page, 329
grid, 328
postamble, 327
preamble, 326
data filtering, 141
filter expression values, 142
global amble
IS9CConfig2::GetGlobalAmble, 211
IS9CConfig2::SetGlobalAmble, 212
operators, 144
Unit Manager, 350
VN_CLASS_ASIC, 266
VN_CLASS_BOOTSTRAP, 266
VN_CLASS_KBD, 266
Volume
bar code configuration, 368
configuration parameter, 356
WAN radio CORE module, 111
WAN radio IDs
ITC_DEVID_WANRADIO_NONE, 268
ITC_DEVID_WANRADIO_SIEMENS_MC45, 268
ITC_DEVID_WANRADIO_SIERRA_SB555, 268
WAN rado CORE module
phone application, 115
700 Series Color Mobile Computer User’s Manual
terminal application, 114
WAP pages, 62
connecting to an ISP, 68
Warm boot
IOCTL_HAL_REBOOT, 278
IOCTL_HAL_WARMBOOT, 275
Web addresses. See URLs
Web browsers, FTP support, 259
Web pages, 62
connecting to an ISP, 68
Web support, xviii
Welch Allyn 1470 Imager
cabling, 232
settings, 232
WEP encryption, 802.11 radio module, 91
Windows configuration, unit information control panel,
WinCfg CAB file, 345
Windows Media files, Windows Media Player, 57
Windows Media Player, Pocket PC, 57
Wireless Application Protocol. See WAP pages
Wireless network, 87
Wireless printing
Bluetooth compatible module, 120
unit information control panel
PDWPM0C CAB file, 345
WP_SAMPLE.CAB file, 345
Wireless TCP/IP installations, BlockSize parameter, 252
Wireless WAN
AT command interface
CDMA/1xRTT SB555, 116
GPRS/GSM GEM350X, 116
GPRS/GSM MC45, 116
CDMA/1xRTT, 110
GEM350x, 110
GSM/GPRS, 110
SB555, 110
testing AT commands, 117
wNumberOfMessages, IADC::QueryData, 155
Word documents. See Pocket Word
Work
creating
a modem connection, 70
an Ethernet connection, 71
getting connected, 70
Writing mode, Pocket Word, 50
Writing on the screen
See also Notes
Pocket Word, 50
Writing to drivers
DTR, 135
NPCP, 130
wStructSize, IBarCodeReaderControl::Read, 165
WWAN. See Wireless WAN
Xscale processor ID, IOCTL_GET_CPU_ID, 280
397
Index
Files Index
Numbers
80211API.DLL, 100
80211CONF.EXE, 100
80211SCAN.EXE, 100
AUTOUSER.DAT, 79
CABWIZ.DDF, 249
CABWIZ.EXE, 236, 249
CEIMAGER.EXE, 80
CPL802.CPL, 100
DEVICEID.H, 272
EXITME.BIN, 259
FTPDCE.EXE, 256, 259
AutoFTP, 261
FTP Server, 251
FTPDCE.TXT, 259
IADC.H, IADC functions, 151
IADCDEVICE.H
IADC::SetAttribute, 157
IBarCodeReaderControl::SetAttribute, 167
INTERMEC.MIB, 125
IS9CCONFIG.H
IS9CConfig functions, 172
IS9CConfig2 functions, 204
ITCADC.MIB, 125
ITCDEVMGMT.H, 149
ITCDEVMGMT.LIB, 149
ITCSNMP.MIB, 125
ITCTERMINAL.MIB, 125
ITCUUID.LIB
IADC functions, 151
IS9CConfig functions, 172
398
IS9CConfig2 functions, 204
MAKECAB.EXE, 249
MOD80211.DLL, 100
NETWLAN.DLL, 100
NPCPPORT.DLL, 129
NRINET.INI, 345
OEMIOCTL.H
IOCTL_GET_CPU_ID, 280
IOCTL_HAL_COLDBOOT, 275
IOCTL_HAL_GET_BOOT_DEVICE, 277
IOCTL_HAL_GET_BOOTLOADER_VERINFO,
274
IOCTL_HAL_GET_OAL_VERINFO, 273
IOCTL_HAL_GET_RESET_INFO, 276
IOCTL_HAL_ITC_READ_PARM, 265
IOCTL_HAL_ITC_WRITE_SYSPARM, 270
IOCTL_HAL_REBOOT, 278
IOCTL_HAL_WARMBOOT, 275
ONEIL.DLL, 134
PKFUNCS.H
IOCTL_HAL_GET_DEVICEID, 272
IOCTL_PROCESSOR_INFORMATION, 279
REBOOTME.BIN, 259
__RESETMEPLEASE__.T XT, 248
RPM.EXE, 241
RPMCE212.INI, 241
SETUP.DLL, 240, 248
DllMain, 248
SRDEVMGMT.CAB, 286
TAHOMA.TTF, 241
WCESTART.INI, 241
700 Series Color Mobile Computer User’s Manual
Corporate Headquarters
6001 36th Avenue West
Everett, Washington 98203
tel 425.348.2600
fax 425.355.9551
www.intermec.com
700 Series Color Mobile Computer User’s Manual - November 2002
*961054031*
*961054031* REV B

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2002:12:14 00:15:06Z
Modify Date                     : 2003:01:13 10:11:36-06:00
Page Count                      : 418
Creation Date                   : 2002:12:14 00:15:06Z
Mod Date                        : 2003:01:13 10:11:36-06:00
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : thinga
Metadata Date                   : 2003:01:13 10:11:36-06:00
Creator                         : thinga
Title                           : back_let85x11
Has XFA                         : No
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EHA700C-SMC45-1

Navigation menu