Intermec Technologies 700C-SMC45 Pen-notepad computer with Radio Interfaces User Manual back let85x11
Intermec Technologies Corporation Pen-notepad computer with Radio Interfaces back let85x11
Contents
User Manual pt 4
Chapter 7 — Programming S ITC_NVPARM_SERVICE_DATE This IOCTL returns the device’ s date of last service in BCD YYYY/ MM/DD format. Four bytes are returned in the buffer pointed to by the lpOutBuffer parameter. S ITC_NVPARM_DISPLAY_TYPE This IOCTL returns the device’ s display type. One byte is returned in the buffer pointed to by the lpOutBuffer parameter. S ITC_NVPARM_EDG_IP This IOCTL returns the device Ethernet debug IP address. Four bytes are returned in the buffer pointed to by the lpOutBuffer parameter. S ITC_NVPARM_EDBG_SUBNET This IOCTL returns the device Ethernet debug subnet mask. Four bytes are returned in the buffer pointed to by the lpOutBuffer parameter. S ITC_NVPARM_ECN This IOCTL returns ECNs applied to the device in a bit array format. Four bytes are returned in the buffer pointed to by the lpOutBuffer parameter. S ITC_NVPARM_CONTRAST This IOCTL returns the device default contrast setting. Two bytes are returned in the buffer pointed to by the lpOutBuffer parameter. S ITC_NVPARM_MCODE This IOCTL returns the manufacturing configuration code for the device. Sixteen bytes are returned in the buffer pointed to by the lpOutBuffer parameter. S ITC_NVPARM_VERSION_NUMBER This IOCTL returns the firmware version for various system components. These values for the ClassId field of the PARMS structure are allowed when ITC_NVPARM_VERSION_NUMBER is used in the id field: S VN_CLASS_KBD Returns a five-byte string, including null terminator, that contains an ASCII value which represents the keyboard microprocessor version in the system. The format of the string is x.xx with a terminating null character. S VN_CLASS_ASIC Returns a five-byte string, including null terminator, that contains an ASCII value which represents the version of the FPGA firmware in the system. The format of the string is x.xx with a terminating null character. S VN_CLASS_BOOTSTRAP Returns a five-byte string, including null terminator, that contains an ASCII value which represents the version of the Bootstrap Loader firmware in the system. The format of the string is x.xx with a terminating null character. 266 700 Series Color Mobile Computer User’s Manual Chapter 7 — Programming S ITC_NVPARM_INTERMEC_SOFTWARE_CONTENT This IOCTL reads the manufacturing flag bits from the non-volatile data store that dictates certain software parameters. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer that indicates if Intermec Content is enabled in the XIP regions. TRUE indicates that it is enabled. FALSE indicates that it is not enabled. S ITC_NVPARM_ANTENNA_DIVERSITY This IOCTL reads the state of the antenna diversity flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer that indicates if there is a diversity antenna installed. TRUE indicates that it is installed. FALSE indicates that it is not installed. S ITC_NVPARM_WAN_RI This IOCTL reads the state of the WAN ring indicator flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer that indicates the polarity of the WAN RI signal. TRUE indicates active high. FALSE indicates active low. S ITC_NVPARM_RTC_RESTORE This IOCTL reads the state of the real-time clock restore flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the RTC will be restored upon a cold boot. FALSE indicates that the RTC will not be restored. S ITC_NVPARM_INTERMEC_DATACOLLECTION_SW This IOCTL reads the state of the data collection software enabled flag. A BOOLEAN DWORD is returned in the buffer pointer to by lpOutBuffer that indicates the data collection software is to be installed at boot time. FALSE indicates the data collection software should not be installed. S ITC_NVPARM_INTERMEC_DATACOLLECTION_HW This IOCTL reads the data collection hardware flags. A BYTE is returned in the buffer pointer to by lpOutBuffer that indicates the type of data collection hardware installed. The maximum possible value returned is ITC_DEVID_SCANHW_MAX. S ITC_DEVID_SCANHW_NONE No scanner hardware is installed. S ITC_DEVID_OEM2D_IMAGER OEM 2D imager is installed. S ITC_DEVID_INTERMEC2D_IMAGER Intermec 2D imager is installed. S ITC_DEVID_SE900_LASER SE900 laser is installed. S ITC_DEVID_SE900HS_LASER SE900HS laser is installed. The high bit indicates whether the S6 scanning engine is installed. The bit mask for this is ITC_DEVID_S6ENGINE_MASK. A non-zero value indicates that the S6 scanning engine is installed. 700 Series Color Mobile Computer User’s Manual 267 Chapter 7 — Programming S ITC_NVPARM_WAN_INSTALLED This IOCTL reads the state of the WAN radio installed flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the WAN radio is installed. FALSE indicates that no WAN radio is installed. S ITC_NVPARM_WAN_FREQUENCY This IOCTL reads the state of the WAN radio frequency flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the WAN radio frequency is United States. FALSE indicates that the WAN radio frequency is European. S ITC_NVPARM_WAN_RADIOTYPE This IOCTL reads the WAN radio ID installed by manufacturing. A BYTE is returned in the buffer pointer to by lpOutBuffer which indicates the type of WAN radio hardware installed. The maximum possible value returned is ITC_DEVID_WANRADIO_MAX. The current definitions are: S ITC_DEVID_WANRADIO_NONE No WAN radio installed. S ITC_DEVID_WANRADIO_SIERRA_SB555 CDMA Sierra Wireless radio. S ITC_DEVID_WANRADIO_XIRCOM_GEM3503 GSM/GPRS Intel (Xircom) radio. S ITC_DEVID_WANRADIO_SIEMENS_MC45 GSM/GPRS Siemens radio. S ITC_NVPARM_80211_INSTALLED This IOCTL reads the state of the 802.11b radio installed flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the 802.11b radio is installed. FALSE indicates that no 802.11b radio is installed. S ITC_NVPARM_80211_RADIOTYPE This IOCTL reads the 802.11b radio ID installed by manufacturing. A BYTE is returned in the buffer pointer to by lpOutBuffer that indicates the type of 802.11b radio hardware installed. The maximum possible value returned is ITC_DEVID_80211RADIO_MAX. The current definitions are: S ITC_DEVID_80211RADIO_NONE No 802.11b radio installed. S ITC_DEVID_80211RADIO_INTEL_2011B Intel 2011B radio installed. S ITC_NVPARM_BLUETOOTH_INSTALLED This IOCTL reads the state of the Bluetooth radio installed flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the Bluetooth radio is installed. FALSE indicates that no Bluetooth radio is installed. 268 700 Series Color Mobile Computer User’s Manual Chapter 7 — Programming S ITC_NVPARM_SERIAL2_INSTALLED This IOCTL reads the state of the serial 2 (COM2) device installed flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the serial 2 device is installed. FALSE indicates that no serial 2 device is installed. S ITC_NVPARM_VIBRATE_INSTALLED This IOCTL reads the state of the vibrate device installed flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the vibrate device is installed. FALSE indicates that no vibrate device is installed. S ITC_NVPARM_LAN9000_INSTALLED This IOCTL reads the state of the Ethernet device installed flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the Ethernet device is installed. FALSE indicates that no Ethernet device is installed. S ITC_NVPARM_SIM_PROTECT_HW_INSTALLED This IOCTL reads the state of the SIM card protection hardware installed flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the SIM card protection hardware is installed. FALSE indicates that no SIM card protection hardware is installed. S ITC_NVPARM_SIM_PROTECT_SW_INSTALLED This IOCTL reads the state of the SIM card protection software installed flag. A BOOLEAN DWORD is returned in the buffer pointed to by lpOutBuffer. TRUE indicates that the SIM card protection software is installed. FALSE indicates that no SIM card protection software is installed. 700 Series Color Mobile Computer User’s Manual 269 Chapter 7 — Programming IOCTL_HAL_ITC_WRITE_SYSPARM Describes and enables the registry save location. Usage #include “oemioctl.h” Syntax BOOL KernelIoControl( IOCTL_HAL_ITC_WRITE_SYSPARM,LPVOID lpInBuf,DWORD nInBufSize, LPVOID lpOutBuf, DWORD nOutBufSize, LPDWORD lpBytesReturned ); Parameters lpInBuf A single byte that may be one of the id values. See “ID Field Values” below. nInBufSize Must be set to the size of the lpInBuf in bytes. lpOutBuf Must point to a buffer large enough to hold the data to be written to the non-volatile data store. nOutBufSize The size of lpOutBuf in bytes. lpBytesReturned The number of bytes returned by the function. Return Values Returns TRUE if function succeeds. Returns FALSE if the function fails. GetLastError() may be used to get the error value. Either ERROR_INVALID_PARAMETER or ERROR_INSUFFICIENT_BUFFER may be returned when this function is used to get the error. ID Field Values The id field of lpInBuf may be one of the following values: S ITC_REGISTRY_LOCATION This IOCTL sets the default location for where to write the registry when RegFlushKey() is called by an application. The registry may be saved to Flash, a CompactFlash storage card or a SecureDigital storage card. lpOutBuf must point to a buffer that contains a byte value of “1” for the CompactFlash card or “2” for the SecureDigital card to specify the location. S ITC_REGISTRY_SAVE_ENABLE This function enables or disables the save registry to non-volatile media feature of the RegFlushKey() function. lpOutBuf must be set to zero (FALSE) if the feature is to be disabled or one (TRUE) if the feature is to be enabled. S ITC_ DOCK_SWITCH This IOCTL sets a position of the dock switch. The dock switch may be set to either “modem” or “serial” positions. lpOutBuf must point to a buffer that contains a byte value of either DOCK_MODEM or DOCK_SERIAL as defined in OEMIOCTL.H; the value specifies the position the switch is to be set. 270 700 Series Color Mobile Computer User’s Manual Chapter 7 — Programming S ITC_ WAKEUP_MASK This IOCTL sets a bit mask that represents the mask for the five programmable wakeup keys. The I/O key is not a programmable wakeup key. By default it is always the system resume key and all other keys are set to disable key wakeup. A zero in a bit position masks the wakeup for that key. A one in a bit position enables wakeup for that key. lpOutBuf must point to a buffer that contains a byte value of a wakeup mask consisting of the OR’ ed constants as defined in OEMIOCTL.H. Only the following keys are programmable as wakeup events. #define #define #define #define #define SCANNER_TRIGGER 1 SCANNER_LEFT SCANNER_RIGHT 4 GOLD_A1 GOLD_A2 0x10 S ITC_AMBIENT_KEYBOARD This IOCTL sets the threshold for the keyboard ambient sensor. This can be a value from 0 (always off ) to 255 (always on). lpOutBuf must point to a buffer that contains a byte value of the desired setting. S ITC_AMBIENT_FRONTLIGHT This IOCTL sets the threshold for the frontlight ambient sensor. This can be a value from 0 (always off ) to 255. lpOutBuf must point to a buffer that contains a byte value of the desired setting. 700 Series Color Mobile Computer User’s Manual 271 Chapter 7 — Programming IOCTL_HAL_GET_DEVICEID This IOCTL returns the device ID. There are two types of device IDs supported, which are differentiated based on the size of the output buffer. The UUID is returned if the buffer size is set to sizeof(UNIQUE_DEVICEID), otherwise the oldstyle device ID is returned. Usage #include “pkfuncs.h” #include “deviceid.h” Syntax BOOL KernelIoControl( IOCTL_HAL_GET_DEVICEID,LPVOID lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters lpInBuf Should be set to NULL. STRICT_ID settings are not supported. lpInBufSize Should be set to zero. lpOutBuf Must point to a UNIQUE_DEVICEID structure as defined by DEVICEID.H if the UUID is to be returned. nOutBufSize The size of the UNIQUE_DEVICEID in bytes if the UUID is to be returned. A DEVICE_ID as defined by PKFUNCS.H is returned if the size in bytes is greater than or equal to sizeof(DEVICE_ID). lpBytesReturned The number of bytes returned by the function. Return Values Returns TRUE if function succeeds. Returns FALSE if the function fails. GetLastError() may be used to get the extended error value. 272 700 Series Color Mobile Computer User’s Manual Chapter 7 — Programming IOCTL_HAL_GET_OAL_VERINFO Returns the HAL version information of the Pocket PC image. Usage #include “oemioctl.h” Syntax BOOL KernelIoControl( IOCTL_HAL_GET_OAL_VERINFO,LPVOID lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters lpInBuf Should be set to NULL. lpInBufSize Should be set to zero. lpOutBuf Must point to a VERSIONINFO structure as defined by OEMIOCTL.H. The fields should have these values: sizeof (tagOemVerInfo); S cboemverinfo S verinfover S sig; “ITC\0” S id; ‘ N’ S tgtcustomer “” tgtplat SeaRay S tgtplatversion Current build version number S tgtcputype[8]; “Intel\0” S tgtcpu “PXA250\0”; S tgtcoreversion “” S date Build time S time Build date nOutBufSize The size of VERSIONINFO in bytes. lpBytesReturned Returns sizeof(PVERSIONINFO). Return Values Returns TRUE if function succeeds. Returns FALSE if the function fails. GetLastError() may be used to get the extended error value. 700 Series Color Mobile Computer User’s Manual 273 Chapter 7 — Programming IOCTL_HAL_GET_BOOTLOADER_VERINFO Returns the HAL version information of the Pocket PC image. Usage #include “oemioctl.h” Syntax BOOL KernelIoControl( IOCTL_HAL_GET_OAL_VERINFO,LPVOID lpInBuf, DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters lpInBuf Should be set to NULL. lpInBufSize Should be set to zero. lpOutBuf Must point to a VERSIONINFO structure as defined by OEMIOCTL.H. The fields should have these values: Sizeof (tagOemVerInfo); S cboemverinfo S verinfover S sig; “ITC\0” S id; ‘ B’ S tgtcustomer “” tgtplat SeaRay S tgtplatversion Current build version number of the bootstrap loader S tgtcputype[8]; “Intel\0”; S tgtcpu “PXA250\0” S tgtcoreversion “” S date Build time S time Build date nOutBufSize The size of VERSIONINFO in bytes. lpBytesReturned The number of bytes returned to lpOutBuf. Return Values Returns TRUE if function succeeds. Returns FALSE if the function fails. GetLastError() may be used to get the extended error value. 274 700 Series Color Mobile Computer User’s Manual Chapter 7 — Programming IOCTL_HAL_WARMBOOT Causes the system to perform a warm-boot. The object store is retained. Usage #include “oemioctl.h” Syntax BOOL KernelIoControl( IOCTL_HAL_WARMBOOT,LPVOID lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters lpInBuf Should be set to NULL. lpInBufSize Should be set to zero. lpOutBuf Should be NULL. nOutBufSize Should be zero. Return Values None. IOCTL_HAL_COLDBOOT Causes the system to perform a cold-boot. The object store is cleared. Usage #include “oemioctl.h” Syntax BOOL KernelIoControl( IOCTL_HAL_COLDBOOT,LPVOID lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters lpInBuf Should be set to NULL. lpInBufSize Should be set to zero. lpOutBuf Should be NULL. nOutBufSize Should be zero. Return Values None. 700 Series Color Mobile Computer User’s Manual 275 Chapter 7 — Programming IOCTL_HAL_GET_RESET_INFO This IOCTL code allows software to check the type of the most recent reset. Usage #include “oemioctl.h” Syntax BOOL KernelIoControl( IOCTL_HAL_GET_RESET_INFO,LPVOID lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters lpInBuf Should be set to NULL. lpInBufSize Should be set to zero. lpOutBuf Must point to a HAL_RESET_INFO structure: typedef struct { DWORD ResetReason; DWORD ObjectStoreState; } HAL_RESET_INFO, * PHAL_RESET_INFO; // most recent reset type // state of object store // Reset reason types #define HAL_RESET_TYPE_UNKNOWN #define HAL_RESET_REASON_HARDWARE #define HAL_RESET_REASON_SOFTWARE #define HAL_RESET_REASON_WATCHDOG #define HAL_RESET_BATT_FAULT #define HAL_RESET_VDD_FAULT 16 // Object store state flags #define HAL_OBJECT_STORE_STATE_UNKNOWN #define HAL_OBJECT_STORE_STATE_CLEAR nOutBufSize // cold // suspend // power fail // warm boot The size of HAL_RESET_INFO in bytes. lpBytesReturned The number of bytes returned by the function. Return Values Returns TRUE if function succeeds. Returns FALSE if the function fails. GetLastError() may be used to get the extended error value. 276 700 Series Color Mobile Computer User’s Manual Chapter 7 — Programming IOCTL_HAL_GET_BOOT_DEVICE This IOCTL code allows software to check which device CE booted from. Usage #include “oemioctl.h” Syntax BOOL KernelIoControl( IOCTL_HAL_GET_BOOT_DEVICE,LPVOID lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters lpInBuf Should be set to NULL. lpInBufSize Should be set to zero. lpOutBuf Must point to a buffer large enough to hold a DWORD (4 bytes) that contains the boot device. The following boot devices are supported: #define #define #define #define #define #define #define HAL_BOOT_DEVICE_UNKNOWN HAL_BOOT_DEVICE_ROM_XIP HAL_BOOT_DEVICE_ROM HAL_BOOT_DEVICE_PCMCIA_ATA HAL_BOOT_DEVICE_PCMCIA_LINEAR HAL_BOOT_DEVICE_IDE_ATA HAL_BOOT_DEVICE_IDE_ATAPI nOutBufSize The size of lpOutBuf in bytes (4). lpBytesReturned The number of bytes returned by the function. Return Values Returns TRUE if function succeeds. Returns FALSE if the function fails. GetLastError() may be used to get the extended error value. 700 Series Color Mobile Computer User’s Manual 277 Chapter 7 — Programming IOCTL_HAL_REBOOT Causes the system to perform a warm-boot. The object store is retained. Usage #include “oemioctl.h” Syntax BOOL KernelIoControl( IOCTL_HAL_REBOOT,LPVOID lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters lpInBuf Should be set to NULL. lpInBufSize Should be set to zero. lpOutBuf Should be NULL. nOutBufSize Should be zero. Return Values None. 278 700 Series Color Mobile Computer User’s Manual Chapter 7 — Programming IOCTL_PROCESSOR_INFORMATION Returns processor information. Usage #include “pkfuncs.h” Syntax BOOL KernelIoControl( IOCTL_PROCESSOR_INFORMATION,LPVOID lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters Parameters: lpInBuf Should be set to NULL. lpInBufSize Should be set to zero. lpOutBuf Should be a pointer to the PROCESSOR_INFO structure. The PROCESSOR_INFO structure stores information that describes the CPU more descriptively. typedef WORD WCHAR WORD WCHAR WORD WCAHR WCHAR DWORD DWORD __PROCESSOR_INFO { wVersion; szProcessorCore[40]; wCoreRevision; szProcessorName[40]; wProcessorRevision; szCatalogNumber[100]; szVendor[100]; dwInstructionSet; dwClockSpeed; nOutBufSize // // // // // // // // // Set to value 1 “ARM\0” “PXA250\0” “Intel Corporation\0” 400 Should be set to sizeof(PROCESSOR_INFO) in bytes. lpBytesReturned Returns sizeof(PROCESSOR_INFO); Return Values Returns TRUE if function succeeds. Returns FALSE if the function fails. GetLastError() may be used to get the extended error value. 700 Series Color Mobile Computer User’s Manual 279 Chapter 7 — Programming IOCTL_GET_CPU_ID Returns Xscale processor ID. Usage #include “oemioctl.h” Syntax BOOL KernelIoControl( IOCTL_GET_CPU_ID,LPVOID lpInBuf, DWORD nInBufSize,LPVOID lpOutBuf,DWORD nOutBufSize,LPDWORD lpBytesReturned ); Parameters lpInBuf Should point to a CPUIdInfo structure defined in OEMIOCTL.H. lpInBufSize Should be sizeof(CPUIdInfo). lpOutBuf Should be NULL. nOutBufSize Should be set to 0. lpBytesReturned Returns sizeof(PROCESSOR_INFO); Return Values Returns TRUE if function succeeds. Returns FALSE if the function fails. GetLastError() may be used to get the extended error value. Reboot Functions There are several methods, via Kernel I/O Control functions, that an application program can use to force the 700 Series Computer to reboot. IOCTL_HAL_REBOOT IOCTL_HAL_REBOOT performs a warm-boot. See page 278. IOCTL_HAL_COLDBOOT Invoking the KernelIOControl function with IOCTL_HAL_COLDBOOT forces a cold reboot. This resets the 700 Series Computer and reloads Windows CE as if a power-up had been performed. The contents of the Windows CE RAM-based object store are discarded. See page 275. IOCTL_HAL_WARMBOOT This function is supported on the 700 Series Computers. It performs a warm boot of the system, preserving the object store. See page 275. 280 700 Series Color Mobile Computer User’s Manual Chapter 7 — Programming Remapping the Keypad Note; Use caution when remapping the keypad. Improper remapping may render the keypad unusable. Data within the 700 Series Computer could also be lost, should any problems occur. Applications have the ability to remap keys on the 700 Color Keypad. This will allow applications to enable keys that would otherwise not be available, such as the [F1] function key. Also, to disable keys that should not be available, such as the alpha key because no alpha entry is required. Care should be exercised when attempting to remap the keypad because improper remapping may cause the keypad to become unusable. This can be corrected by cold booting the device which will cause the default keymap to be loaded again. Note that remapping the keys in this way affects the key mapping for the entire system, not just for the application that does the remapping. There are three “planes” supported for the 740 Keypad. Keys that are to be used in more than one shift plane must be described in each plane. Unshifted Plane The unshifted plane contains values from the keypad when not pressed with other keys, such as the following: S [1] S [5] S [9] Gold Plane The gold plane contains values from the keypad when a key is simultaneously pressed with the [Gold] key, such as the following: S [Gold] + [1] Send S [Gold] + [5] A3 S [Gold] + [9] PageDown Alpha Plane The alpha plane contains values from the keypad when the keypad has been placed in alpha mode by pressing the blue alpha key, such as the following: S [Alpha] + [1] Caps S [Alpha] + [5] JKL S [Alpha] + [9] WXYZ 700 Series Color Mobile Computer User’s Manual 281 Chapter 7 — Programming Key Values Key values for each plane are stored in the registry. All units ship with a default key mapping already loaded in the registry. Applications that wish to change the default mapping need to read the appropriate key from the registry into an array of Words, modify the values required and then write the updated values back into the registry. The registry access can be done with standard Microsoft API calls, such as RegOpenKeyEx(), RegQueryValueEx(), and RegSetValueEx(). S The unshifted plane mapping can be found in the registry at: HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\KEYBD\Vkey S The gold plane mapping can be found in the registry at: HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\KEYBD\VkeyGold S The alpha plane mapping can be found in the registry at: HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\KEYBD\VkeyAlpha How Key Values Are Stored in Registry To know which fields to update in the registry, you must know what Scan Codes are assigned to each physical key (see the table below). The Scan Code is used at the lowest level of the system to let the keypad driver know which physical key has been pressed. The keypad driver takes that scan code and looks it up in a table (a copy of the one stored in the registry) to determine which values to pass on to the operating system. Each registry key is just an array that describes to the keypad driver what value needs to be passed for each physical key. The key values are indexed by the scan code, this is a zero-based index. For example in the unshifted plane, the [4] key has a scan code of 0x06. This means that the seventh word under the “Vkey” registry key will have the value for the [4] key. Taking a sample of the “Vkey” registry key shows the following values: 00,00,0B,05,02,03,C1,07,04,03,BE,00,34,00,00,00,. . . The value is 34,00. The values are in reverse byte order because that is the way the processor handles data. When writing an application, nothing needs to be done to swap the bytes, as this will happen automatically when the data is read into a byte value. This is something you just need to be aware of this when looking at the registry. Knowing this, we can see that the value that the keypad driver will pass to the system is a hex 34. Looking that up on an UNICODE character chart, we see that it maps to a “4”. If you wanted the key, labeled “4”, to output the letter “A” instead, you would need to change the seventh word to “41” (the hexadecimal representation of “A” from the UNICODE chart), then put the key back into the registry. Note: Do not remap scan codes 0x01, 0x41, 0x42, 0x43, 0x44. Remapping these scan codes could render your 700 Series Computer unusable until a cold-boot is performed. If you wish to disable a certain key, remap its scan code to 0x00. 282 700 Series Color Mobile Computer User’s Manual Chapter 7 — Programming Change Notification Just changing the registry keys will not immediately change the key mappings. To notify the keypad driver that the registry has been updated, signal the “ITC_KEYBOARD_CHANGE” named event using the CreateEvent() API. Advanced Keypad Remapping It is also possible to map multiple key presses to one button and to map named system events to a button. The multiple key press option could be useful to cut down on the number of keys needed to press in a given situation or to remap which key behaves like the action key. Mapping events to a button could be useful to change which buttons will fire the scanner, control volume, and allow for suspending and resuming the device. If you need help performing one of these advanced topics please contact Intermec Technical Support. Scan Codes At the lowest driver level, the 740 Keypad identifies keys as scan codes. These scan codes are sent via the keypad microcontroller, and cannot be changed without modifying the keypad firmware. Key/Meaning Reserved I/O Button Scanner Trigger Scanner Left Scanner Right None Left Arrow None Backspace Gold Key None ESC Down Arrow Alpha Key None Up Arrow Right Arrow None 700 Series Color Mobile Computer User’s Manual Scancode 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B 0x0C 0x0D 0x0E 0x0F 0x10 0x11 0x12 0x13 0x14 0x15 0x16 0x17 0x18 0x19 283 Chapter 7 — Programming Key/Meaning Action Key ENTER None Charge Detect Scancode 0x1A 0x1B 0x1C 0x1D 0x1E 0x1F-0x40 0x41 LCD Frontlight Ambient Light Threshold Crossed 0x42 0x42 0x42 Headset Detected 0x43 Keypad Backlight Ambient Light Threshold Crossed 0x44 0x44 0x44 Sample View of Registry Keys The following is a sample view of the current default key mapping. See the registry on your device for the latest key mappings. [HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\KEYBD] ”ResumeMask”=dword:7 ”Vkey”=hex: 00,00,0B,05,02,03,C1,07,04,03,BE,00,34,00,00,00,\ 25,00,00,00,08,00,03,02,00,00,1B,00,28,00,31,00,\ 37,00,01,02,00,00,26,00,27,00,32,00,38,00,30,00,\ 35,00,00,00,01,03,33,00,39,00,0D,00,36,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,07,05,01,05,03,05,02,05 ”VkeyGold”=hex: 00,00,0B,05,02,03,C1,07,04,03,BE,00,34,00,00,00,\ 09,01,00,00,BF,00,03,02,00,00,BD,00,75,00,72,00,\ 21,00,01,02,00,00,76,00,09,00,73,00,38,01,5B,00,\ 35,00,00,00,BB,01,09,05,22,00,32,01,36,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,07,05,01,05,03,05,02,05 ”VkeyAlpha”=hex: 00,00,0B,05,02,03,C1,07,04,03,BE,00,47,00,00,00,\ 25,00,00,00,08,00,03,02,00,00,1B,00,28,00,02,02,\ 50,00,01,02,00,00,26,00,27,00,41,00,54,00,20,00,\ 4A,00,00,00,01,03,44,00,57,00,0D,00,4D,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,07,05,01,05,03,05,02,05 284 700 Series Color Mobile Computer User’s Manual A Control Panel Applets This appendix contains information about the Data Collection, SNMP, and User Information Control Panel applets that may be on your 700 Series Color Mobile Computer. SNMP and Data Collection settings that can appear under Settings are dependent on what hardware configuration is done for each 700 Series Computer at the time of shipment. These settings will currently only appear if a scanner or an imager option is present. Likewise, other control panel applets that are specifically related to the 802.11b radio module will appear when a 802.11b radio module is installed in a 700 Series Computer. Control panel applets that are specific for Wireless Printing, CDMA/1xRTT, and GSM/GPRS radio modules will only appear when each respective hardware configuration is done on the 700 Series Computer. See Chapter 4, “Network Support,” for more information about the radio modules or the wireless printing. 700 Series Color Mobile Computer User’s Manual 285 Appendix A — Control Panel Applets Configuration Parameters A configuration parameter changes the way the 700 Series Color (700C) Mobile Computer operates, such as configuring a parameter to have the 700 Series Computer emit a very loud beep in a noisy environment. Use any of the following methods to execute configuration parameters: S Change Data Collection and SNMP parameters via control panel applets later in this appendix. S Access the 700 Series Computer via the Unit Manager through a web browser on your desktop PC via the SRDEVMGMT.CAB file. To use the Unit Manager, install this CAB file from the 700 Color Software Tools CD-ROM. Unit Manager applications are available on the 700 Series Color Unit Manager CD-ROM. For more information, consult your Intermec sales representative. S Send parameters from an SNMP management station. See “SNMP Configuration” starting on page 123. S Scan EasySet bar codes. You can use the EasySet bar code creation software from Intermec Technologies Corporation to print configuration labels. Scan the labels to change the scanner configuration and data transfer settings. Changing a Parameter Setting Menus of available parameters for each group are listed. Use the scroll bars to go through the list. Expand each menu (+) to view its parameter settings. Tap a parameter to select, or expand a parameter (+) to view its subparameters. Note that each parameter or subparameter is shown with its default setting or current setting in (< >) brackets. Tap a parameter or subparameter to select that parameter, then do any of the following to change its setting: Tap Apply to apply any changes. Note that these illustrations are from a Symbologies parameter. S Typing a new value in an entry field. S Choosing a new value from the drop-down list. S Selecting a different option. The selected option contains a bullet. S Tap Defaults, then Apply to restore factory-default settings. Tap Yes when you are prompted to verify this action. 286 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets S Tap Refresh to discard changes and start again. Tap Yes when you are prompted to verify this action. About Configuration Parameters You can find the following information about each configuration parameter: S Name and Purpose: Describes the parameter and its function. S Action: Describes what to do with a parameter once that parameter is selected. S SNMP OID: Lists the SNMP OID for the parameter. S Syntax or Options: Syntax lists the two-character code for the parameter, if the parameter is configurable by scanning a bar code or by sending parameters through a network. Both Syntax and Options list acceptable values for the parameter. Default settings are noted in italic. 700 Series Color Mobile Computer User’s Manual 287 Appendix A — Control Panel Applets Data Collection Control Panel Applet See “Scanner Control and Data Transfer” in the Intermec Windows CE/Pocket PC Software Developer’ s Kit (SDK) User’ s Manual shipped with the Software Developer’ s Kit (SDK) for information about data collection functions. Note: Icons are shown to the left. To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Data Collection icon to access its control panel applet. Use the left and right arrows to scroll through the tabs along the bottom of the control panel applet, then tap a tab to access its menus. These tabs represent the following groups of settings or parameters: S Symbologies S Symbology Options (starting on page 309) S Beeper/LED (starting on page 317) S Imager (starting on page 323) S Virtual Wedge (starting on page 325) 288 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Symbologies You can change bar code symbology parameter settings in your 700 Series Computer via the Data Collection control panel applet. The following parameters are for bar code symbologies. Additional information about the more common bar code symbologies are in Appendix C, “Bar Code Symbologies.” Note that these parameters are listed in the order of their appearance within this tab. Most of these symbologies apply to both the imager and the laser scanner tools. However, when using an imager, the Macro PDF (page 300), Micro PDF 417 (page 302), Matrix 2 of 5 (page 304), Telepen (page 305), and Code 11 (page 306) symbologies are not supported. Likewise, when using a laser scanner, the QR Code (page 307) and Data Matrix (page 308) symbologies are not supported. The following table shows which bar code symbologies are supported either by an imager or by a laser scanner. Bar Code Symbology Imager Laser Scanner Code 39 Interleaved 2 of 5 Standard 2 of 5 Matrix 2 of 5 Code 128 Code 93 Codabar MSI Plessey UPC EAN/EAN 128 Code 11 PDF 417 Micro PDF 417 Telepen Data Matrix QR Code 700 Series Color Mobile Computer User’s Manual 289 Appendix A — Control Panel Applets Code 39 Code 39 is a discrete, self-checking, variable length symbology. The character set is uppercase A-Z, 0-9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). Action Tap (+) to expand the Code 39 parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.3.1 Options Decoding Not active Active (default) Format Standard 43 characters (default) Full ASCII Start/Stop Not transmitted (default) Transmitted Start/Stop characters (Not supported when using an imager): $ (dollar sign) only * (asterisk) only (default) & and * (dollar sign and asterisk) Check digit Not used (default) Mod 43 transmitted Mod 43 not transmitted French CIP transmitted French CIP not transmitted Italian CPI transmitted Italian CPI not transmitted Bar code length Any length (default) Minimum length Minimum length 000-254 Minimum length 1-254 (6) Note: If Bar code length = “1” then Minimum length is entered. 290 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Standard 2 of 5 Standard 2 of 5 is a discrete and self-checking symbology that uses the bars to encode information and the spaces to separate the individual bars. Action Tap (+) to expand the Standard 2 of 5 parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.4.1 Options Decoding Format Check digit Bar code length Minimum length Fixed length 1 Fixed length 2 Fixed length 3 001-254 000-254 000-254 000-254 Not active (default) Active Identicon, 6 start/stop bars (default) Computer Identics, 4 start/stop Not used (default) Mod 10 transmitted Mod 10 not transmitted Any length Minimum length (default) Fixed lengths Minimum length 1-254 (6) Fixed bar code length 0-254 (0) Fixed bar code length 0-254 (0) Fixed bar code length 0-254 (0) Note: If Bar code length = “1” then Minimum length is entered. If Bar code length = “2” then Fixed length 1, Fixed length 2, or Fixed length 3 is entered. 700 Series Color Mobile Computer User’s Manual 291 Appendix A — Control Panel Applets Codabar Codabar is a self-checking, discrete symbology. Action Tap (+) to expand the Codabar parameter, select a setting to be changed, then select an option from the drop-down list to change this setting. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.5.1 Options Decoding Not active (default) Active Start/Stop Not transmitted (default) abcd transmitted ABCD transmitted abcd/tn*e transmitted DC1`DC4 transmitted CLSI library system (Not supported when using an imager): Not active (default) Active Check digit Not used (default) Transmitted Not transmitted Bar code length Any length Minimum length (default) Fixed lengths Minimum length 003-254 Minimum length 3-254 (6) Fixed length 1 000-254 Fixed length 0-254 (0) Fixed length 2 000-254 Fixed length 0-254 (0) Fixed length 3 000-254 Fixed length 0-254 (0) Note: If Bar code length = “1” then Minimum length is entered. If Bar code length = “2” then Fixed length 1, Fixed length 2, or Fixed length 3 is entered. 292 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets UPC/EAN UPC/EAN are fixed-length, numeric, continuous symbologies that use four element widths. Action Tap (+) to expand the UPC/EAN parameter, select the setting to be changed, then select an option to change this setting. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.6.1 Options UPC A 0 Not active 1 Active (default) UPC E 0 Not active 1 Active (default) EAN 8 0 Not active 1 Active (default) EAN 13 0 Not active 1 Active (default) Add-on digits 0 Not required (default) 1 Required Add-on 2 digits 0 Not active (default) 1 Active Add-on 5 digits (Not supported when using an imager): 0 Not active (default) 1 Active UPC A check digit 0 Not transmitted 1 Transmitted (default) UPC E check digit 0 Not transmitted 1 Transmitted (default) EAN 8 check digit 0 Not transmitted 1 Transmitted (default) EAN 13 check digit 0 Not transmitted 1 Transmitted (default) UPC A number system 0 Not transmitted 1 Transmitted (default) UPC E number system 0 Not transmitted 1 Transmitted (default) UPC A re-encoding 0 UPC A transmitted as EAN 13 (default) 1 UPC A transmitted as UPC A UPC E re-encoding 0 UPC E transmitted as UPC E (default) 1 UPC E transmitted as UPC A EAN 8 re-encoding 0 EAN 8 transmitted as EAN 8 (default) 1 EAN 8 transmitted as EAN 13 700 Series Color Mobile Computer User’s Manual 293 Appendix A — Control Panel Applets Code 93 Code 93 is a variable length, continuous symbology that uses four element widths. Action Tap the Code 93 parameter, then select an option to change this parameter setting. Tap (+) to access the Code 93 Lengths parameter. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.7.1 Options Not active (default) Active Code 93 Length Sets the Code 93 bar code length. Action Tap (+) to expand the Code 93 parameter, then tap (+) to expand the Code 93 Lengths parameter. Tap the setting to be changed, then tap an option to change this setting. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.19.1 Options Bar code length Minimum length 001-254 Any length (default) Minimum length Minimum length 1-254 (6) Note: If Bar code length = “1” then Minimum length is entered. 294 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Code 128 Code 128 is a variable-length, continuous, high-density, alphanumeric symbology that uses multiple element widths and supports the extended ASCII character set. Action Tap the Code 128 parameter, then select an option to change this parameter setting. The following illustration is for a 700 Series Computer using a laser scanner. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.9.1 Options Not active (default) Active 700 Series Color Mobile Computer User’s Manual 295 Appendix A — Control Panel Applets Code 128 Options Set the following for the Code 128 parameter. Note that the EAN 128 ]C1 and CIP 128 French Pharmaceutical options are not available when you use an imager with your 700 Series Computer. Action Tap (+) to expand the Code 128 Options parameter, select a setting, then select an option to change this setting. SNMP OID None. Options EAN 128 ]C1 Identifier (disabled when using an imager) Remove Include (default) CIP 128 French Pharmaceutical (disabled when using an imager) Not active (default) Active Bar code length Any length (default) Minimum length Minimum length 001-254 Minimum length 1-254 (6) 296 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Code 128 FNC1 Character The Code 128 FNC1 character (EAN 128 norms) can be any ASCII character and is used as a separator when multiple identifiers and their fields are concatenated. Note that this is not available when you use an imager with your 700 Series Computer. Non-printable ASCII characters can be entered using the following syntax where HH is the hexadecimal value of the character. \xHH For example, the GS character, whose hexadecimal value is 1D, would be entered as \x1D. In addition,the following characters have their own identifiers: S BEL \a S BS \b S FF \f S LF \n S CR \r S HT \t S VT \v Action Tap (+) to expand the Code 128 parameter, then type the ASCII characters to be set for the Code 128 FNC1 character parameter. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.21.1 Options Any ASCII character (default is the GS function character - ID hex) 700 Series Color Mobile Computer User’s Manual 297 Appendix A — Control Panel Applets Plessey Plessey is a pulse-width modulated symbology like most other bar codes. It includes a start character, data characters, an eight-bit cyclic check digit, and a termination bar. The code is continuous and not self-checking. You need to configure two parameters for Plessey code: Start Code and Check Digit. Note that this is not available when you use an imager with your 700 Series Computer. Action Tap (+) to expand the Plessey parameter, select the setting to be changed, then select an option to change this setting or select an option from the drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.10.1 Options Decoding Check digit Bar code length Minimum length 001-254 Not active (default) Active Not transmitted (default) Transmitted Any length (default) Minimum length Minimum bar code length 1-254 (6) Note: If Bar code length = “1” then Minimum length is entered. 298 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets MSI MSI is a symbology similar to Plessey code (page 298) that includes a start pattern, data characters, one or two check digits, and a stop pattern. Note that this is not available when you use an imager with your 700 Series Computer. Action Tap (+) to expand the MSI parameter, select the setting to be changed, then select an option to change this setting or select an option from the drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.15.1 Options Decoding Check digit Bar code length Minimum length 001-254 Not active (default) Active Mod 10 transmitted (default) Mod 10 Not transmitted Double Mod 10 transmitted Double Mod 10 not transmitted Any length Minimum length (default) Minimum length 1-254 (6) Note: If Bar code length = “1” then Minimum length is entered. 700 Series Color Mobile Computer User’s Manual 299 Appendix A — Control Panel Applets PDF 417 PDF 417 is a stacked two-dimensional symbology that provides the ability to scan across rows of code. Each row consists of start/stop characters, row identifiers, and symbol characters, which consist of four bars and four spaces each and contain the actual data. This symbology uses error correction symbol characters appended at the end to recover loss of data. Because the virtual wedge translates incoming data into keypad input, the size of the keypad buffer limits the effective length of the label to 128 characters. Longer labels may be truncated. For PDF 417 labels of more than 128 characters, you can develop an application that bypasses the keypad buffer. Action Tap the PDF 417 parameter, then select an option to change this parameter setting. Tap (+) to access either the Macro PDF options parameter or the Micro PDF 417 parameter. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.17.1 Options Not active Active (default) Macro PDF options Macro PDF is used when a long message requires more than one PDF 417 label. Note that this is not available when you use an imager with your 700 Series Computer. S Select Buffered to store a multi-label PDF 417 message in the Sabre buffer, thus transmitting the entire message when all labels have been read. 300 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets S Select Unbuffered for multi-label PDF 417 messages that are too long for the Sabre buffer (memory overflow). Each part of the PDF 417 label is transmitted separately, and the host application must then assemble the message using the macro PDF control header transmitted with each label. Control Header is only present in macro PDF codes and is always transmitted with unbuffered option. Action Tap (+) to expand the PDF 417 parameter, tap (+) to expand the Macro PDF parameter, select a setting to be changed, then select an option to change this setting. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.22.1 Options Macro PDF Control header File name Segment count Time stamp Sender Addressee File size Checksum 700 Series Color Mobile Computer User’s Manual Unbuffered Buffered (default) Not transmitted (default) Transmitted Not transmitted (default) Transmitted Not transmitted (default) Transmitted Not transmitted (default) Transmitted Not transmitted (default) Transmitted Not transmitted (default) Transmitted Not transmitted (default) Transmitted Not transmitted (default) Transmitted 301 Appendix A — Control Panel Applets Micro PDF 417 Micro PDF 417 is a multi-row symbology derived from and closely based on PDF 417 (page 300). A limited set of symbology sizes is available, together with a fixed level of error correction for each symbology size. Note that this is not available when you use an imager with your 700 Series Computer. Action Tap (+) to expand the PDF 417 parameter, tap (+) to expand the Micro PDF 417 parameter, select a setting to be changed, then select an option to change this setting. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.27.1 Options Decoding Code 128 Emulation 302 Not active (default) Active Not active (default) Active 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Interleaved 2 of 5 Interleaved 2 of 5 (I 2 of 5) is a high-density, self-checking, continuous, numeric symbology used mainly in inventory distribution and the automobile industry. Note: An Interleaved 2 of 5 bar code label must be at least three characters long for the 700 Series Computer to scan and decode correctly. Action Tap (+) to expand the Interleaved 2 of 5 parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.23.1 Options Decoding Not active (default) Active Check digit Not used (default) Mod 10 transmitted Mod 10 not transmitted French CIP transmitted French CIP not transmitted Bar code length Any length Minimum length (default) Fixed lengths Minimum length 003-254 Minimum length 3-254 (6) Fixed length 1 003-254 Fixed length 3-254 (0) Fixed length 2 003-254 Fixed length 3-254 (0) Fixed length 3 003-254 Fixed length 3-254 (0) Note: If Bar code length = “1” then Minimum length is entered. If Bar code length =“2” then Fixed length 1, Fixed length 2, or Fixed length 3 is entered. 700 Series Color Mobile Computer User’s Manual 303 Appendix A — Control Panel Applets Matrix 2 of 5 Matrix 2 of 5 is a numerical symbology. Note that this is not available when you use an imager with your 700 Series Computer. Action Tap (+) to expand the Matrix 2 of 5 parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.24.1 Options Decoding Bar code length Minimum length 001-254 Not active (default) Active Any length Minimum length (default) Minimum length 1-254 (6) Note: If Bar code length = “1” then Minimum length is entered. 304 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Telepen Telepen is an alphanumeric, case-sensitive, full ASCII symbology. Note that this is not available when you use an imager with your 700 Series Computer. Action Tap (+) to expand the Telepen parameter, select the setting to be changed, then tap an option to change this setting. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.25.1 Options Decoding Format Not active (default) Active ASCII (default) Numeric 700 Series Color Mobile Computer User’s Manual 305 Appendix A — Control Panel Applets Code 11 Code 11 is a high density, discrete numeric symbology that is extensively used in labeling telecommunications components and equipment. Note that this is not available when you use an imager with your 700 Series Computer. Action Tap (+) to expand the Code 11 parameter, select the setting to be changed, then tap an option to change this setting. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.26.1 Options Decoding Check digit verification Check digit transmit 306 Not active (default) Active 1 digit (default) 2 digits Disable (default) Enable 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets QR Code QR Code (Quick Response Code) is a two-dimensional matrix symbology containing dark and light square data modules. It has position detection patterns on three of its four corners and features direct encodation of the Japanese Kana-Kanji character set. It can encode up to 2509 numeric or 1520 alphanumeric characters and offers three levels of error detection. Note that this is not available when you use a laser scanner with your 700 Series Computer. Action Tap (+) to expand the QR Code parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.35.1 Options Decoding 0 Not active 1 Active (default) 700 Series Color Mobile Computer User’s Manual 307 Appendix A — Control Panel Applets Data Matrix A two-dimensional matrix symbology, which is made of square modules arranged within a perimeter finder pattern. The symbology utilizes Error Checking and Correcting (ECC) algorithm with selectable levels for data error recovery and Cyclic Redundancy Check algorithm to validate the data. The character set includes either 128 characters conforming to ISO 646 (ANSI X3.4 - 1986) or 256 extended character set. Maximum capacity of a symbol is 2335 alphanumeric characters, 1556 8-bit byte characters or 3116 numeric digits. Note that this is not available when you use a laser scanner with your 700 Series Computer. Action Tap (+) to expand the Data Matrix parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.3.3.1.1.34.1 Options Decoding 0 Not active 1 Active (default) 308 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Symbology Options To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Data Collection icon to access its control panel applet. Use the right and left arrows to scroll to the Symbology Options tab, then tap this tab to access its parameters. The following are parameters for bar code symbology options. Note that these are listed in the order of their appearance within the Symbology Options tab. Symbology ID Identifies the bar code symbology in which data has been encoded by prepending a user-specified symbology identifier to the data. You can prepend one of these types of character strings to identify the symbology: S User-defined ASCII Character (Option 1): A user-defined symbology identifier is a single ASCII character. You can assign a custom identifier character to each bar code symbology. Note that this is not available when you use an imager with your 700 Series Computer. S AIM ISO/IEC Standard (Option 2 - Required to define symbology IDs): The AIM Standard has a three-character structure which indicates the symbology and optional features. See the AIM ISO/IEC Standard for more information. Action Select Symbology ID, then select an option to change this parameter setting. Tap (+) to expand the Symbology ID parameter, then select any of the user ID parameters listed. See the top of the next page for a sample screen of the Code 39 user ID. SNMP OID 1.3.6.1.4.1.1963.15.3.3.4.1.22.1 Options Disable (default) User defined (disabled when using an imager) ISO/IEC Standard 700 Series Color Mobile Computer User’s Manual 309 Appendix A — Control Panel Applets Code 39 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Code 39 bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Code 39 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.3.1 Options: x where x is a single ASCII character. Default is asterisk (*). Code 128 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Code 128 bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Code 128 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.5.1 Options: x where x is a single ASCII character. Default is asterisk (*). Codabar User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Codabar bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Codabar user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.2.1 Options: x 310 where x is a single ASCII character. Default is D. 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Code 93 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Code 93 bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Code 93 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.4.1 Options: x where x is a single ASCII character. Default is asterisk (*). Interleaved 2 of 5 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Interleaved 2 of 5 bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Interleaved 2 of 5 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.10.1 Options: x where x is a single ASCII character. Default is I (not lowercase L). PDF-417 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify PDF 417 bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the PDF 417 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.12.1 Options: x where x is a single ASCII character. Default is an asterisk (*). MSI User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify MSI bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the MSI user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.11.1 Options: x where x is a single ASCII character. Default is D. 700 Series Color Mobile Computer User’s Manual 311 Appendix A — Control Panel Applets Plessey User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Plessey bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Plessey user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.13.1 Options: x where x is a single ASCII character. Default is D. Standard 2 of 5 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Standard 2 of 5 bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Standard 2 of 5 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.23.1 Options: x where x is a single ASCII character. Default is D. UPC A User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify UPC-A (Universal Product Code) bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the UPC A user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.6.1 Options: x where x is a single ASCII character. Default is A. UPC E User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify UPC-E bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the UPC E user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.7.1 Options: x 312 where x is a single ASCII character. Default is E. 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets EAN 8 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify EAN-8 bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the EAN 8 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.8.1 Options: x where x is a single ASCII character. Default is \xFF. EAN 13 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify EAN-13 (European Article Numbering) bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the EAN 13 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.9.1 Options: x where x is a single ASCII character. Default is F. Matrix 2 of 5 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Matrix 2 of 5 bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Matrix 2 of 5 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.24.1 Options: x where x is a single ASCII character. Default is D. Telepen User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Telepen bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Telepen user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.25.1 Options: x where x is a single ASCII character. Default is an asterisk (*). 700 Series Color Mobile Computer User’s Manual 313 Appendix A — Control Panel Applets Code 11 User ID If “1” was selected in the Symbology ID parameter, you can set your own ASCII character to identify Code 11 bar code data. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Symbology ID parameter, select the Code 11 user ID parameter, then enter a user ID value to change this parameter setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.4.1.16.1 Options: x 314 where x is a single ASCII character. Default is asterisk (*). 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Prefix Prepends a string of up to 20 ASCII characters to all scanned data. Action Tap the Prefix parameter, then enter a prefix value to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.3.4.1.29.1 Options Acceptable values are up to 20 ASCII characters. Embedded null () characters are not allowed. Default is no characters (disabled). 700 Series Color Mobile Computer User’s Manual 315 Appendix A — Control Panel Applets Suffix Appends a string of up to 20 ASCII characters to all scanned data. Action Tap the Suffix parameter, then enter a suffix value to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.3.4.1.30.1 Options Acceptable values are up to 20 ASCII characters. Embedded null ( ) characters are not allowed. Default is no characters (disabled). 316 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Beeper/LED To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Data Collection icon to access its control panel applet. Use the right and left arrows to scroll to the Beeper/LED tab, then tap this tab to access its parameters. Most of these functions are not available when using an imager. The following table shows which functions are supported either by an imager or by a laser scanner. Beeper Function Imager Laser Scanner Beeper Volume Beeper Frequency Good Read Beeps Good Read Beep Duration The following are parameters for features on the 700 Series Computer. Note that these are listed in the order of their appearance. 700 Series Color Mobile Computer User’s Manual 317 Appendix A — Control Panel Applets Beeper Volume Sets the volume for the good read beep. Action Tap the Beeper volume parameter, then select an option to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.1.4.1.6.1 Laser Scanner Options 318 Low High (default) Medium Off Vibrate 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Imager Options Beeper (default) Vibrate Silencing the Beeper Volume To turn the beeper off, tap Start → Settings → the Personal tab → Sounds and Notifications → the Volume tab, drag the System volume slider bar to the left “Silent” position, then tap ok to exit this applet. 700 Series Color Mobile Computer User’s Manual 319 Appendix A — Control Panel Applets Beeper Frequency Sets the frequency for the good read beep. Note that this is not available when you use an imager with your 700 Series Computer. Action Tap the Beeper frequency parameter, then enter a frequency value to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.1.4.1.7.1 Options 1000-4095 (default is 2090) 320 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Good Read Beeps Sets the number of good read beeps. Note that this is not available when you use an imager with your 700 Series Computer. Action Tap the Good read beeps parameter, then select an option to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.1.4.1.8.1 Options No beeps One beep (default) Two beeps 700 Series Color Mobile Computer User’s Manual 321 Appendix A — Control Panel Applets Good Read Beep Duration Sets the duration of the good read beep. Note that this is not available when you use an imager with your 700 Series Computer. Action Tap the Good read beep duration parameter, then enter a duration value to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.1.4.1.9.1 Options 0`2550 322 Beep duration in milliseconds. (default is 80) 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Imager To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Data Collection icon to access its control panel applet. Use the right and left arrows to scroll to the Imager tab, then tap this tab to access its parameters. The following are parameters for the imager. Note that these are listed in the order of their appearance within the Imager tab. Aimer LED duration The Aimer LED duration controls the time the Aimer LED is turned on when the scan button is pressed. After this time, images are captured for decoding. The purpose is to position the Aimer LED on the bar code symbol before attempting to decode the bar code. Note that this is not available when you use a laser scanner with your 700 Series Computer. Action Tap the Aimer LED duration parameter, then enter a value to change this setting. Note that values must be in 50 ms increments, such as 500, 650, or 32500. Values not entered in 50 ms increments will be rounded down. For example, 2489 ms would be rounded down to 2450 ms, 149 ms would be rounded down to 100 ms, etc.. SNMP OID 1.3.6.1.4.1.1963.15.3.3.3.1.1.21.1 Options 0-65500 ms (Default is 0) 700 Series Color Mobile Computer User’s Manual 323 Appendix A — Control Panel Applets Image Dimension The image dimensions control the horizontal size of the image for decoding. This can restrict the image to one bar code when otherwise, there might be more than one bar code in the image to be decoded. Note that this is not available when you use a laser scanner with your 700 Series Computer. Action Tap the Image dimension parameter, select the position to be changed, then tap an option or enter a value to change this position. SNMP OID 1.3.6.1.4.1.1963.15.3.3.3.1.1.22.1 Options Left position Right position Top position Bottom position 324 0-478 0-479 Not supported Not supported Position in pixels (0) Position in pixels (479) 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Virtual Wedge To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Data Collection icon to access its control panel applet. Use the right and left arrows to scroll to the Virtual Wedge tab, then tap this tab to access its parameters. The following are parameters for the virtual wedge scanner. Note that these are listed in the order of their appearance within the Virtual Wedge tab. Virtual Wedge Enables or disables the virtual wedge for the internal scanner. The virtual wedge retrieves scanned Automatic Data Collection (ADC) data and sends it to the keypad driver so that the 700 Series Computer can receive and interpret the data as keypad input. Because the virtual wedge translates incoming data into keypad input, the size of the keypad buffer limits the effective length of the label to 128 characters. Longer labels may be truncated. For labels of more than 128 characters, you need to develop an application that bypasses the keypad buffer. Action Tap the Virtual Wedge parameter, then tap an option to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.2.1.1.2.1 Options Disable Enable (default) 700 Series Color Mobile Computer User’s Manual 325 Appendix A — Control Panel Applets Preamble Sets the preamble that precedes any data you scan with the 700 Series Computer. Common preambles include a data location number or an operator number. Action Tap the Preamble parameter, then enter a preamble value to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.2.1.1.3.1 Syntax ADdata where data is acceptable values up to 31 ASCII characters. Embedded null ( ) characters are not allowed. Default is no characters (disabled). Note: When you enter the AD command without data, the preamble is disabled. If you want to use quotation marks or the following combinations of characters as part of the appended data, separate those characters from the AD command with quotes. If you do not use quotes as described here, the 700 Series Computer will interpret the characters as another configuration command: AD AE AF KC BV EX DF EXAMPLE: To use the two-character string BV as a preamble, scan this command (as a Code 39 label) or send this command through the network: $+AD“BV” 326 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Postamble Sets the postamble that is appended to any data you scan with the 700 Series Computer. Common postambles include cursor controls, such as tabs or carriage return line feeds. Action Tap the Postamble parameter, then enter a postamble value to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.2.1.1.4.1 Syntax AEdata where data is any acceptable values up to 31 ASCII characters. Embedded null ( ) characters are not allowed. Default is the tab character (\t). Note: When you enter the AE command without data, the postamble is disabled. If you want to use quotation marks or the following combinations of characters as part of the appended data, separate those characters from the AE command with quotes. If you do not use quotes as described here, the 700 Series Computer will interpret the characters as another configuration command. AD AE AF KC BV EX DF EXAMPLE: To use the two-character string BV as a postamble, scan this command (as a Code 39 label) or send this command through the network: $+AE“BV” 700 Series Color Mobile Computer User’s Manual 327 Appendix A — Control Panel Applets Grid Sets the virtual wedge grid, which filters the data coming from this 700 Series Computer. The data server supports data filtering, which allows you to selectively send scanned data. The virtual wedge grid is similar to the “format” argument of the C Runtime Library scan function. Action Tap the Grid parameter, then enter a grid value to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.2.1.1.5.1 Syntax AF filter-expression= > editing-expression where: S The AIM symbology ID. S filter-expression Any character string that includes valid filter expression values, and editing-expression is any character string that includes valid editing expression values. S Any positive integer or NULL. A NULL width means that the field type (defined next) applies all the way to the end of the data string. A nonNULL width means that the field applies to that many characters of data. The grid can be up to 240 characters in length. Default is NULL. 328 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Code Page Sets the virtual wedge code page. The code page controls the translation from the character set of the raw collected data to Unicode, which is the character set expected by Windows CE applications. The default code page is 1252, which is the Windows Latin 1 (ANSI) character set. Action Tap the Code Page parameter, then select an option to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.15.3.2.1.1.6.1 Options The only acceptable value for the code page parameter is “1252,” which is the default. 700 Series Color Mobile Computer User’s Manual 329 Appendix A — Control Panel Applets SNMP Control Panel Applet Simple Network Management Protocol (SNMP) parameters include identification information, security encryption, security community strings, and traps. To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the SNMP icon to access its control panel applet. Tap a tab to access its menus. These tabs represent three groups of settings or parameters: S Security (starting on the next page) S Traps (starting on page 336) S Identification (starting on page 338) 330 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Security To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the SNMP icon → the Security tab to access its parameters. The following are parameters that affect encryption and community strings. Note that these are listed in the order of their appearance within the Security tab. Read Only Community Sets the read-only community string for this 700 Series Computer, which is required for processing of SNMP get and get next requests. Action Tap the Read Only Community parameter, then enter a community string to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.10.5.1.2.0 Options The read-only community string can be up to 128 ASCII characters. Default is Public. 700 Series Color Mobile Computer User’s Manual 331 Appendix A — Control Panel Applets Read/Write Community Sets the read/write community string, which is required for processing of SNMP set requests by this 700 Series Computer. An SNMP packet with this name as the community string will also process SNMP get and next requests. Action Tap the Read/Write Community parameter, then enter a community string to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.10.5.1.3.0 Options The read/write community string can be up to 128 ASCII characters. Default is Private. 332 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Read Encryption Sets the packet-level mode of security for SNMP read-only requests. If you enable read encryption, all received SNMP get and get next packets have to be encrypted or the packet will not be authorized. If encryption is enabled, you can only use software provided by Intermec Technologies. Note: To enable security encryption, you also need to set the Security Encryption Key (page 335). Action Tap the Read Encryption parameter, then select an option to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.10.5.1.4.0 Options On SNMP get and get next packets must be encrypted Off SNMP packets do not have to be encrypted (default) 700 Series Color Mobile Computer User’s Manual 333 Appendix A — Control Panel Applets Write Encryption Sets the packet-level mode of security for SNMP read/write requests. If you enable write encryption, all SNMP packets that are received with the read/write community string have to be encrypted or the packet will not be authorized. You need to use software from Intermec Technologies that supports encryption. Note: To enable security encryption, you also need to set the Security Encryption Key (page 335). Action Tap the Write Encryption parameter, then select an option to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.10.5.1.5.0 Options 334 On SNMP packets must be encrypted Off SNMP packets do not have to be encrypted (default) 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Encryption Key Identifies the key that this 700 Series Computer uses to encrypt or decipher SNMP packets. Encryption is used only by software provided by Intermec Technologies. If encryption is enabled, SNMP management platforms will not be able to communicate with the 700 Series Computer. The encryption key is returned encrypted. Action Tap the Encryption Key parameter, then enter a security encryption key value to change this parameter setting. Note: You also need to set either Read Encryption (page 333) or Write Encryption (page 334) or both. SNMP OID 1.3.6.1.4.1.1963.10.5.1.6.0 Options The encryption key can be from 4 to 20 ASCII characters. Default is NULL. 700 Series Color Mobile Computer User’s Manual 335 Appendix A — Control Panel Applets Traps To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the SNMP icon → the Traps tab to access its parameters. The following are authentication and threshold parameters for traps. Note that these are listed in the order of their appearance within the Traps tab. Authentication Determines whether to send authentication traps. When trap authentication is enabled, an authentication trap is sent if an SNMP packet is received by the master agent with an invalid community string. Action Tap the Authentication parameter, then select an option to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.10.5.2.2.0 Options 336 On (default) Off 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Threshold Determines the maximum number of traps per second that the master agent generates. If the threshold is reached, the trap will not be sent. Action Tap the Threshold parameter, then enter a threshold value to change this parameter setting. SNMP OID 1.3.6.1.4.1.1963.10.5.2.3.0 Options Any positive integer value. Default is 10. 700 Series Color Mobile Computer User’s Manual 337 Appendix A — Control Panel Applets Identification To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the SNMP icon → the Identification tab to access its parameters. The following are parameters for contact, location, and name information for support purposes. Note that these are listed in the order of their appearance within the Identification tab. Contact Sets the contact information for the person responsible for this 700 Series Computer. Action Tap the Contact parameter, then enter the name of your contact representative to change this parameter setting. SNMP OID 1.3.6.1.2.1.1.4.0 Options The identification contact may be up to 255 ASCII characters. Default is no characters or blank. 338 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Name Sets the assigned name for this 700 Series Computer. Action Tap the Name parameter, then enter the name of your 700 Series Computer to change this parameter setting. SNMP OID 1.3.6.1.2.1.1.5.0 Options The identification name may be up to 255 ASCII characters. Default is no characters or blank. 700 Series Color Mobile Computer User’s Manual 339 Appendix A — Control Panel Applets Location Sets the identification location for this 700 Series Computer, such as “Shipping.” Action Tap the Location parameter, then enter the location of where your 700 Series Computer to change this parameter setting. SNMP OID 1.3.6.1.2.1.1.6.0 Options The identification location may be up to 255 ASCII characters. Default is no characters or blank. 340 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Unit Information Control Panel Applet Unit Information is a read-only control panel applet that provides information about your 700 Series Computer, such as software version builds, available CAB files, and the internal battery status. This control panel applet is only available in the 700 Series Computer if Intermec Content is enabled, the Plus region is enabled and installed, and a laser scanner is installed. To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Unit Information icon to access its control panel applet. Tap a tab to access its menus. These tabs represent three groups of settings or parameters: S Versions (starting on the next page) S Battery Status (starting on page 343) S CAB Files (starting on page 344) 700 Series Color Mobile Computer User’s Manual 341 Appendix A — Control Panel Applets Versions You can view the latest software build version on your 700 Series Computer by accessing the Unit Information control panel applet. To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Unit Information icon → the Versions tab to view the latest software build version. Tap ok to exit this information. Below are some of the software applications you may find on this screen: S 700 Platform Build: Shows the latest development or released version of the software build for the 700 Series Computer. S S9C: Provides the name and version of the scanner file built into this 700 Series Computer, along with the current CPU version. S DataCollection Build: Shows the latest development or released version of the software build for the Data Collection control panel applet. 342 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets Battery Status You can view the battery status for your 700 Series Computer by accessing the Unit Information control panel applet. Unit Manager applications are available on the 700 Series Color Unit Manager CD-ROM. For more information, consult your Intermec sales representative. To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Unit Information icon → the Battery Status tab to view the current status. Tap ok to exit this information. 700 Series Color Mobile Computer User’s Manual 343 Appendix A — Control Panel Applets CAB Files You can view the latest developer or released version of each CAB file from Intermec Technologies Corporation that are installed in your 700 Series Computer via the Unit Information control panel applet. Custom CAB files are not displayed in this applet. See the Software Tools User’ s Manual for more information about these files. To access the information from the 700 Series Computer, tap Start → Settings → the System tab → the Unit Information icon → the CAB Files tab to view the current CAB file versions. Tap ok to exit this information. When a CAB file is built, a registry entry is created with a build number for that file. This CAB Files control panel applet looks for a registry key for each CAB file installed. When the registry entry is found, the CAB file name and version number information are displayed. If a CAB file has not been installed, then its information is not displayed. Below is a list of CAB files from Intermec Technologies that are available for your 700 Series Computer with their latest developer or released version of the software build. Should you need to add any of these to your 700 Series Computer, contact an Intermec representative. S BtMainStack: Installation of the Main Bluetooth Stack is handled automatically as part of the operating system boot-up procedure. See Chapter 4, “Network Support,” for more information about Bluetooth wireless printing. S Comm Port Wedge: The software build for the Comm Port Wedge. Note that the Comm Port Wedge CAB file is available on the 700C Tools CD. S NPCPTest: This installs a Norand Portable Communications Protocol (NPCP) Printing test application which will print to an Intermec 4815, 4820, or 6820 Printer. See Chapter 5, “Printer Support,” for more information. 344 700 Series Color Mobile Computer User’s Manual Appendix A — Control Panel Applets S PDWPM0C: This is the installer for the Wireless Printing Demo application. To run this demonstration, tap Start → Programs → the Wireless Printing Demo icon. Press Help in the demo application for more information. S S9C Upgrade: Installs the files needed to upgrade the S9C scanner firmware. See the Recovery CD Help for more information about upgrading the firmware. S SDK: Installs the Intermec Software Developer’ s Kit (SDK). See the SDK User’ s Manual for more information. S Unit Manager: Installs the Unit Manager application which provides tools for remotely managing the 700 Series Computer. Unit Manager applications are available on the 700 Series Color Unit Manager CD-ROM. For more information, consult your Intermec sales representative. S Unit Manager Help: Installs the online help for the Unit Manager application. S WinCfg: Configures the NRINET.INI file, launches the NRINet client, and loads and unloads the LAN and WLAN device drivers. See the Windows 95 and Windows CE Configuration Utilities Reference Manual (P/N: 978-054-010) for more information. S Wireless Printing Sample: Installs a sample application that developers can use for reference when they are developing their own Wireless Printing applications. The source code for this application is included as part of the Wireless Printing SDK on the 700C Tools CD. See the SDK User’ s Manual for more information. S ActiveX Control Tools: This lists some of the CAB files that may be available with which to install ActiveX Control Tools. See the SDK Online Help for more information. S AXCommunication: Communication controls that transmit or receive messages from input connections. S AXFileTransfer: File transfer controls that transmit and receive files using the Trivial File Transfer Protocol (TFTP). S AXReaderCommand: Reader command functions that modify and retrieve configuration information from your 700 Series Computer. S AXVWedge: The virtual wedge control that retrieves scanned ADC data and sends it to the keyboard driver to interpret data as keyboard input. 700 Series Color Mobile Computer User’s Manual 345 Appendix A — Control Panel Applets 346 700 Series Color Mobile Computer User’s Manual B Unit Manager Configuration parameters are also configurable using a Unit Manager application which accesses the 700 Series Computer through a web browser on your desktop PC via the SRDEVMGMT.CAB file. Unit Manager applications are available on the 700 Series Color Unit Manager CD-ROM. For more information, consult your Intermec sales representative. Note: Parameter information, such as SNMP OID and options, is detailed in Appendix A, “Control Panel Applets.” 700 Series Color Mobile Computer User’s Manual 347 Appendix B — Unit Manager Data Collection Within the Unit Manager, click Configuration from the left navigation bar, then click the Data Collection icon to access any of these tabs: Symbologies, Symbology ID, Beeper/LED, or Virtual Wedge. Symbologies Within the Unit Manager, select Configuration Management → Data Collection, then click the Symbologies tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. S Codabar (page 292) S Code 11 (page 306) S Code 128 (page 295) S Code 128 Options (page 296) S Code 128 FNC1 Character (page 297) S Code 39 (page 290) S Code 93 (page 294) S Code 93 Length (page 294) S Data Matrix (page 308) S Interleaved 2 of 5 (page 303) S Matrix 2 of 5 (page 304) S MSI (page 299) S PDF 417 (page 300) S Macro PDF (page 300) S Micro PDF 417 (page 302) S Plessey (page 298) S QR Code (page 307) S Standard 2 of 5 (page 291) S Telepen (page 305) S UPC/EAN (page 293) 348 700 Series Color Mobile Computer User’s Manual Appendix B — Unit Manager Symbology ID Within the Unit Manager, select Configuration Management → Data Collection, then click the Symbology ID tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. S Prefix (page 315) S Suffix (page 316) S Symbology ID (page 309) S Codabar user ID (page 310) S Code 11 user ID (page 314) S Code 128 user ID (page 310) S Code 39 user ID (page 310) S Code 93 user ID (page 311) S EAN-13 user ID (page 313) S EAN-8 user ID (page 313) S Interleaved 2 of 5 user ID (page 311) S Matrix 2 of 5 user ID (page 313) S MSI user ID (page 311) S PDF 417 user ID (page 311) S Plessey user ID (page 312) S Standard 2 of 5 user ID (page 312) S Telepen user ID (page 313) S UPC-A user ID (page 312) S UPC-E user ID (page 312) Beeper/LED Within the Unit Manager, select Configuration Management → Data Collection, then click the Beeper/LED tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. S Beeper Frequency (page 320) S Beeper Volume (page 318) S Good Read Beep Duration (page 322) S Good Read Beeps (page 321) 700 Series Color Mobile Computer User’s Manual 349 Appendix B — Unit Manager Imager Within the Unit Manager, select Configuration Management → Data Collection, then click the Imager tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. S Aimer LED Duration (page 323) S Image Dimension (page 324) Virtual Wedge Within the Unit Manager, select Configuration Management → Data Collection, then click the Virtual Wedge tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. S Code Page (page 329) S Grid (page 328) S Postamble (page 327) S Preamble (page 326) S Virtual Wedge (page 325) SNMP Within the Unit Manager, click Configuration from the left navigation bar, then click the SNMP icon to access any of these tabs: Security, Traps, or Identification. Security Within the Unit Manager, select Configuration Management → SNMP, then click the Security tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. S Encryption Key (page 335) S Read Encryption (page 333) S Read Only Community (page 331) S Read/Write Community (page 332) S Write Encryption (page 334) 350 700 Series Color Mobile Computer User’s Manual Appendix B — Unit Manager Traps Within the Unit Manager, select Configuration Management → SNMP, then click the Traps tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. S Authentication (page 336) S Threshold (page 337) Identification Within the Unit Manager, select Configuration Management → SNMP, then click the Identification tab to access the following parameters. Options for these parameters are listed on the page provided. These are listed in alphabetical order. S Contact (page 338) S Location (page 340) S Name (page 339) 700 Series Color Mobile Computer User’s Manual 351 Appendix B — Unit Manager Unit Within the Unit Manager, click Configuration from the left navigation bar, then click the Unit icon to access any of these tabs: Date/Time, Display, Keypad, Power Management, or Speaker. Date/Time Sets the current date and time. Action Click the Date/Time tab, then select Date or Time and make changes in the entry field, or tap (+) to expand either the Date or Time parameter, select the setting to be changed, then select a value from the drop-down list or enter a new value to change this setting. SNMP OID Date: Time: 1.3.6.1.4.1.1963.15.501.2.1.0 1.3.6.1.4.1.1963.15.501.2.2.0 Options Date Time 352 Year Month Day Hour Minute Second 0000`999 1-12 (6) 1-31 (1) 0-23 (0) 0-59 (00) 0-59 (00) (1999) 700 Series Color Mobile Computer User’s Manual Appendix B — Unit Manager Backlight Timeout Sets the length of time that the display backlight remains on. If you set a longer timeout value, you use the battery power at a faster rate. Action Click the Display tab, then select an option from the Backlight timeout drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.13.1.0 Syntax DFdata where data is any of the following: 10 30 60 120 180 240 300 10 seconds 30 seconds 1 minute (default) 2 minutes 3 minutes 4 minutes 5 minutes 700 Series Color Mobile Computer User’s Manual 353 Appendix B — Unit Manager Key Clicks Enables or disables the keypad clicks. The 700 Series Computer emits a click each time you press a key or decode a row of a two-dimensional symbology. Action Click the Keypad tab, then select an option from the Key clicks dropdown list. SNMP OID 1.3.6.1.4.1.1963.15.12.1.0 Syntax KCdata where data is any of the following: 354 Disable clicks Enable soft key clicks Enable loud key clicks (default) 700 Series Color Mobile Computer User’s Manual Appendix B — Unit Manager Automatic Shutoff Sets the length of time the 700 Series Computer remains on when there is no activity. When you turn on the 700 Computer, it either resumes exactly where it was when you turned it off or boots and restarts your application. Action Click the Power Management tab, then select an option from the Automatic shutoff drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.11.3.0 Syntax EZdata where data is any of the following: 1 minute 2 minutes 3 minutes (default) 4 minutes 5 minutes 700 Series Color Mobile Computer User’s Manual 355 Appendix B — Unit Manager Volume Changes the volume of all audio signals. Action Click the Speaker tab, then select an option from the Volume drop-down list. SNMP OID 1.3.6.1.4.1.1963.15.3.1.3.0 Syntax BVdata where data is any of the following: 356 Off Very quiet Quiet Normal (default) Loud Very loud 700 Series Color Mobile Computer User’s Manual Appendix B — Unit Manager Using Reader Commands After the 700 Series Computer is connected to your network, you can send the 700 Series Computer a reader command from an application to perform a task, such as changing the time and date. Some reader commands temporarily override the configuration settings and some change the configuration settings. Change Configuration The Change Configuration command must precede any configuration command. If you enter a valid string, the 700 Series Computer configuration is modified and the computer emits a high beep. To send the Change Configuration command through the network, use the $+ [command] syntax where command is the two-letter command syntax for the configuration command followed by the value to be set for that command. You can also make changes to several different commands by using the $+ [command]...[command n] syntax. There are seven configuration command settings that can be changed in this way. See each command for information on respective acceptable “data” values. Command Syntax Audio Volume BVdata Automatic Shutoff EZdata Backlight Timeout DFdata Key Clicks KCdata Virtual Wedge Grid AFdata Virtual Wedge Postamble AEdata Virtual Wedge Preamble ADdata Note: See Appendix A, “Control Panel Applets” for more information about the Virtual Wedge Postamble and Virtual Wedge Preamble commands. Example 1 To change the Beep Volume to Off, you can send this string to the 700 Series Computer through the network: $+BV0 where: $+ Indicates Change Configuration. BV Specifies the Audio Volume parameter. Specifies a value of Off. Example 2 To change the Beep Volume to Very Quiet and the Virtual Wedge Grid to 123: $+BV1AF123 where: $+ Indicates Change Configuration BV1 Specifies Audio Volume, set to Very Quiet (1) AF123 Specifies Virtual Wedge Grid, set to a value of 123. 700 Series Color Mobile Computer User’s Manual 357 Appendix B — Unit Manager Set Time and Date This command sets the date and time on the 700 Series Computer. The default date and time is June 1, 1999 at 12:00 AM. From the network, send the following: /+ yyyymmddhhmmss where acceptable values for the date are: yyyy mm dd hh mm ss 0000-9999 Year 01-12 Month of the year 01-31 Day of the month 00-23 Hour 00-59 Minutes 00-59 Seconds You can also set the time and date by using Configuration Management in Unit Manager, or by using the Clock control panel applet in the Settings menu. To access this control panel applet, tap Start → Settings → the System tab → the Clock icon to access its control panel applet. 358 700 Series Color Mobile Computer User’s Manual C Bar Codes This appendix contains a brief explanation of some of the bar code symbologies that the 700 Series Color (700C) Mobile Computer decodes and explains some of the general characteristics and uses of these bar code types. It also includes several bar code labels that can be scanned into your 700 Series Computer. 700 Series Color Mobile Computer User’s Manual 359 Appendix C — Bar Codes Bar Code Symbologies Specific bar code algorithms can be enabled using the setup menus or the host computer. Once the computer correctly decodes a bar code, the computer encodes data with descriptive information about the symbol. Response time is improved by limiting the computer to the bar codes being used. Bar Code Data String Formats Data Bar Code Type Data Format Data Length UPC short (UPC-E) nddddddc EAN short (EAN-8) fndddddc UPC long (UPC-A) nddddddddddc 12 EAN long (EAN-13) fnddddddddddc 13 UPC short add-on 2 nddddddcaa 10 EAN short add-on 2 fndddddcaa 10 UPC long add-on 2 nddddddddddcaa 14 EAN long add-on 2 fnddddddddddcaa 15 UPC short add-on 5 nddddddcaaaaa 13 EAN short add-on 5 fndddddcaaaaa 13 UPC long add-on 5 nddddddddddcaaaaa 17 EAN long add-on 5 fnddddddddddcaaaaa 18 Interleaved 2 of 5 d......d Scan device dependent Standard 2 of 5 d......d Scan device dependent Plessey d......dc Scan device dependent Codabar sd....ds Scan device dependent Code 11 d......d Scan device dependent Code 39 d......d Scan device dependent Extended Code 39 d......d Scan device dependent Code 93 d......d Scan device dependent Code 128 d......d Scan device dependent Note: These bar code data definitions apply to the Data Format column in the previous table a Add-on code digits c Check digits d Bar code digits f EAN flag 1 characters n Number system digits s Start and stop digits If MOD 10 or MOD 11 check digits are enabled, the digit falls at the end of a bar code data string. Each check digit enabled extends the bar code data string length by one character. 360 700 Series Color Mobile Computer User’s Manual Appendix C — Bar Codes The 700 Series Computer recognizes eleven of the most widely used bar code symbologies. With bar code symbologies, like languages, there are many different types. A bar code symbology provides the required flexibility for a particular inventory tracking system. A symbology may be for particular industries, such as food and beverage, automotive, railroad, or aircraft. Some of these industries have established their own bar code symbology because other symbologies did not meet their needs. Without going into great detail on the bar code structure, note that no two products use the same bar code. Each product gets a unique bar code. Industries that use a particular type of bar code symbology have formed regulating committees or are members of national institutes that issue and keep track of bar codes. This ensures that each organization that contributes to a particular industry conforms to its standard. Without some form of governing body, bar coding would not work. S UPC (Universal Product Code) with/without add-ons S EAN (European Article Numbering Code) with/without add-ons S Codabar S C11 (Code 11) S C39 (Code 39) S C93 (Code 93) S C128 (Code 128) S I 2 of 5 (Interleaved 2 of 5 Code) S S 2 of 5 (Standard 2 of 5) S Plessey S MSI (a variant of Plessey) 700 Series Color Mobile Computer User’s Manual 361 Appendix C — Bar Codes UPC The UPC (Universal Product Code) is the symbology used throughout the grocery and retail industries. This bar code symbology contains two pieces of numerical information encoded on the bar code, producer identification, and product identification information. The UPC symbol is 12 characters long. The first character of the UPC symbol is a number system character, such as “0” for grocery items and “3” for drug- and health-related items. The UPC symbology is for retail environments such as grocery stores, convenience stores, and general merchandise stores. Some retail items are so small that a standard UPC bar code cannot fit on the packaging. When this occurs there is a permitted shorter version of the UPC symbology, referred to as UPC-E. UPC-E is six characters long (eight including number system and check digit), approximately half the size of a standard UPC bar code. EAN EAN (European Article Numbering) symbology is similar to UPC symbology, except that it contains 13 characters and uses the first two to identify countries. The EAN symbology is used in the retail environment throughout most of Europe. Though similar to UPC symbology, these are not interchangeable. Codabar Codabar was for retail price-labeling systems. Today it is widely accepted by libraries, medical industries, and photo finishing services. Codabar is a discrete, self-checking code with each character represented by a stand-alone group of four bars and three intervening spaces. Four different start or stop characters get defined and designated “a”, “b”, “c”, and “d”. These start and stop characters are constructed using one wide bar and two wide spaces. A complete Codabar symbol begins with one of the start or stop characters followed by some number of data characters and ending in one of the start or stop characters. Any of the start or stop characters may be used on either end of the symbol. It is possible to use the 16 unique start or stop combinations to identify label type or other information. Since Codabar is variable-length, discrete, and self-checking, it is a versatile symbology. The width of space between characters is not critical and may vary significantly within the same symbol. The character set consists of “0” through “9”, “-”, “$”, “:”, “/”, “.”, and “+”. The specific dimensions for bars and spaces in Codabar optimize performance of certain early printing and reading equipment. Codabar has 18 different dimensions for bar and space widths. So many different dimensions often result in labels printed out of specification and cause Codabar printing equipment to be more expensive. 362 700 Series Color Mobile Computer User’s Manual Appendix C — Bar Codes Code 11 Code 11 satisfies the requirements for a very high density, discrete numeric bar code. The name Code 11 derives from 11 different data characters that can be represented, in addition to a start or stop character. The character set includes the 10 digits and the dash symbol. Each character is represented by a stand-alone group of three bars and two intervening spaces. Although Code 11 is discrete, it is not self-checking. A single printing defect can transpose one character into another valid character. One or two check digits obtain data security. The specifications for Code 11 suggest that this code should have a narrow element width of 7.5 mils. This results in an information density of 15 characters per inch. Code 39 Code 39 (C39) is the most widely used symbology among the industrial bar codes. Most major companies, trade associations, and the federal government find this code to fit their needs. The main feature of this symbology is the ability to encode messages using the full alphanumeric character set, seven special characters, and ASCII characters. Programming for this symbology can be for any length that the application requires. The application program for the 700 Series Computer handles symbology at least one character but no more than 32 characters in length. When programming the computer for Code 39, it is important to set the symbology limit as close as possible (minimum and maximum bar code lengths being scanned). Doing so keeps the computer bar code processing time to a minimum and conserves battery power. Bar code readers can respond to Uniform Symbology Specification symbols in non-standard ways for particular applications. These methods are not for general applications, because of the extra programming required. Code 39 Full ASCII is one example of non-standard code. Note: See page 368 to scan several Code 39 bar code labels available to change settings on your 700 Series Computer. Encoded Code 39 (Concatenation) If the first data character of a symbol is a space, the reader may be programmed to append the information contained in the remainder of the symbol to a storage buffer. This operation continues for all successive symbols that contain a leading space, with messages being added to the end of previously stored ones. When a message is read which does not contain a leading space, the contents are appended to the buffer, the entire buffer is transmitted, and the buffer is cleared. Encoded Code 39 (Full ASCII) If the bar code reader is programmed for the task, the entire ASCII character set (128 characters) could be coded using two character sequences: a symbol (“$”,“.”,“%”,“/”) followed by a letter of the alphabet. 700 Series Color Mobile Computer User’s Manual 363 Appendix C — Bar Codes Code 93 The introduction of Code 93 provided a higher density alphanumeric symbology designed to supplement Code 39. The set of data characters in Code 93 is identical with that offered with Code 39. Each character consists of nine modules arranged into three bars and three spaces. Code 93 uses 48 of the 56 possible combinations. One of these characters, represented by a square, is reserved for a start or stop character, four are used for control characters, and the remaining 43 data characters coincide with the Code 39 character set. An additional single module termination bar after the stop character concludes the final space. Code 93 is a variable length, continuous code that is not self-checking. Bar and spaces widths may be one, two, three, or four modules wide. Its structure uses edge-to-similar-edge decoding. This makes the bar code immune to uniform ink spread, which allows liberal bar width tolerances. Code 93 uses two check characters. Its supporters believes this makes it the highest density alphanumeric bar code. The dual check digit scheme provides for high data integrity. All substitution errors in a single character are detected for any message length. Code 128 Code 128 (C128) is one of the newest symbologies used by the retail and manufacturing industries. It responds to the need for a compact alphanumeric bar code symbol that could encode complex product identification. The fundamental requirement called for a symbology capable of being printed by existing data processing printers (primarily dot-matrix printers) that produce daily, work-in-progress, job, and product traceability documents. The ability to print identification messages between 10 and 32 characters long, on existing forms and labels deemed an important requirement. Code 128 uniquely addresses this need as the most compact, complete, alphanumeric symbology available. Additionally, the Code 128 design with geometric features, improves scanner read performance, does self-checking, and provides data message management function codes. Code 128 encodes the complete set of 128 ASCII characters without adding extra symbol elements. Code 128 contains a variable-length symbology and the ability to link one message to another for composite message transmission. Code 128, being a double-density field, provides two numeric values in a single character. Code 128 follows the general bar code format of start zone, data, check digit, stop code, and quiet zone. An absolute minimum bar or space dimension of nine mils (0.010 inch minimum nominal ± 0.001 inch tolerance) must be maintained. Characters in Code 128 consist of three bars and three spaces so that the total character set includes three different start characters and a stop character. 364 700 Series Color Mobile Computer User’s Manual Appendix C — Bar Codes UCC/EAN-128 Shipping Container Labeling is a versatile tool that can ease movement of products and information. The Shipping Container Labeling bar code can take any form and usually has meaning only within the company or facility where applied. Because this random data can get mistaken later for an industry standard code format, the UCC and EAN chose a symbology uniquely identified from these other bar codes. This standard is for maximum flexibility, to handle the diversity of distribution in global markets by cost efficiency. The UCC/EAN-128 Container Labeling specification calls for a FUNC1 to immediately follow the bar code’ s start character. FUNC1 also follows any variable-length application field. The specification also calls for the computer to send “]C1” for the first FUNC1. The specification requires that the computer send a “ ” (hex 1D) for subsequent FUNC1 codes in the bar code. Because “ ” is not compatible with computer emulation data streams, the Uniform Code Council has been asked to change the specification. This change is made to send the same three character sequence “]C1” to identify the embedded FUNC1 codes. This implementation should provide for clean application coding by identifying the same sequences for the same scanned codes. If the communication of Norand bar code types is enabled, the Shipping Container Label codes precede with a “J”. These strings will appear on the computer display. The application may have to allow for strings longer than 48 characters (maximum length indicated in the specification). Actual length variance depends on the number of variable-length data fields. Allowing for 60 characters should be sufficient. Within the Code 128 specification, the computer can link bar codes together. If this is to happen, allow for more characters (computer limit is 100 characters). The Application Identifier Standard, that is part of the UCC/EAN Shipping Label concept, complements, rather than replaces, other UCC/EAN standards. Most UCC/EAN standards primarily identify products. Several industries expressed the need to standardize more than product identification. The UCC/EAN Code 128 Application Identifier Standard supplies this tool. The standard adds versatility for inter-enterprise exchanges of perishability dating, lot and batch identification, units of use measure, location codes, and several other information attributes. For more detailed information on Code 128 UCC/EAN Shipping Label bar code and Application Identifier Standard, refer to the UCC/EAN-128 Application Identifier Standard specification. 700 Series Color Mobile Computer User’s Manual 365 Appendix C — Bar Codes I 2 of 5 (Interleaved) I 2 of 5 (Interleaved 2 of 5 Code) is an all-numeric symbology, widely used for warehouse and heavy industrial applications. Its use has been particularly prevalent in the automobile industry. The I 2 of 5 symbology can be placed on smaller labels than what the standard UPC symbology requires. I 2 of 5 also provides a little more flexibility on the type of material it can print on. Interleaved 2 of 5 Code has its name because of the way the bar code is configured. I 2 of 5 bars and spaces both carry information. The bars represent the odd number position digits, while spaces represent the even number position digits. The two characters are interleaved as one. Messages encoded with this symbology have to use an even number of characters since two numeric characters always get interleaved together. S 2 of 5 (Standard 2 of 5) The code S 2 of 5 (Standard 2 of 5 Code) is designed primarily for: S Warehouse inventory handling S Identification of photo finishing envelopes S Airline tickets S Baggage and cargo handling The code S 2 of 5 is simple and straightforward. All information is contained in the widths of the bars, with the spaces serving only to separate the individual bars. Bars can either be wide or narrow, and the wide bars are usually three times the widths of the narrow bars. Spaces may be any reasonable width but are typically equal to the narrow bars. Narrow bars are identified as zero bits and wide bars as one bits. Remember the code structure by associating the bar positions from left to right with weighting factors 1, 2, 4, 7, and parity. Exceptions to this rule are zero, start, and stop. This code is a discrete code, since the white spaces between the characters are not part of the code. Because the white spaces carry no information, their dimensions are not critical. The S 2 of 5 code is self-checking, meaning a scanner passing through a printing void would detect the proper ratio of wide bars to total bars. When the scanner spots an error, a non-read will occur. 366 700 Series Color Mobile Computer User’s Manual Appendix C — Bar Codes Plessey Plessey finds its origin in the pulse width modulated (PWM) code developed in England. It is widely used for shelf markings in grocery stores. Pulse width modulated codes represent each bit of information by a bar and space pair. A zero bit consists of a narrow bar followed by a wide space, while a one bit consists of a wide bar followed by a narrow space. It is mainly a numeric symbology (0-9) with six extra characters available for assigning any symbol or letter desired. Plessey codes are not self-checking and employ a variety of check characters. Plessey employs a polynomial-based Cyclic Redundancy Check (CRC). For start and stop characters, Plessey employs a 1101 and previously used a 0101. This symbology is very limited about what information can be encoded. It is not considered for new applications. MSI Code (Variant of Plessey) In addition to Plessey characteristics, the MSI Code employs a Modulus 10 Check. For start and stop checks, MSI employs a single bit pair of 1 as a start symbol and a single bit pair of 0 as a stop symbol. MSI reverses the 1-2-4-8 BCD pattern for bit pair weighting to 8-6-2-1. 700 Series Color Mobile Computer User’s Manual 367 Appendix C — Bar Codes Bar Code Labels You can change some settings on your 700 Series Computer by scanning the following Code 39 bar code labels. S You can use the Unit Manager application to set the Automatic Shutoff, Volume, Backlight Timer, or Key Clicks parameters (starting on page 352). S You can use the Unit Manager application or the Data Collection control panel to set the three Virtual Wedge parameters (starting on page 325). Note: When you use a bar code creation utility to make a scannable bar code label, the utility probably adds opening and closing asterisks automatically. Asterisks are included here for translation purposes. Audio Volume Note: The Audio Volume parameter information is on page 356. Turn Audio Off *$+BV0* *$+BV0* Set Audio Volume to very quiet *$+BV1* *$+VB1* Set Audio Volume to quiet *$+BV2* *$+BV2* Set Audio Volume to normal (default) *$+BV3* *$+BV3* Set Audio Volume to loud *$+BV4* *$+BV4* Set Audio Volume to very loud *$+BV5* *$+BV5* 368 700 Series Color Mobile Computer User’s Manual Appendix C — Bar Codes Automatic Shutoff Note: The Automatic Shutoff parameter information is on page 355. Set Automatic Shutoff to 1 minute *$+EZ1* *$+EZ1* Set Automatic Shutoff to 2 minutes *$+EZ2* *$+EZ2* Set Automatic Shutoff to 3 minutes (default) *$+EZ3* *$+EZ3* Set Automatic Shutoff to 4 minutes *$+EZ4* *$+EZ4* Set Automatic Shutoff to 5 minutes *$+EZ5* *$+EZ5* Backlight Timeout Note: The Backlight Timeout parameter information is on page 353. Backlight Timeout 10 seconds *$+DF10* *$+DF10* Backlight Timeout 30 seconds *$+DF30* *$+DF30* Backlight Timeout 1 minute (default) *$+DF60* *$+DF60* 700 Series Color Mobile Computer User’s Manual 369 Appendix C — Bar Codes Backlight Timeout 2 minutes *$+DF120* *$+DF120* Backlight Timeout 3 minutes *$+DF180* *$+DF180* Backlight Timeout 4 minutes *$+DF240* *$+DF240* Backlight Timeout 5 minutes *$+DF300* *$+DF300* Key Clicks Note: The Key Clicks parameter information is on page 354. Disable key clicks *$+KC0* *$+KC0* Enable soft key clicks *$+KC1* *$+KC1* Enable loud key clicks (default) *$+KC2* *$+KC2* 370 700 Series Color Mobile Computer User’s Manual Appendix C — Bar Codes Virtual Wedge Grid, Preamble, Postamble The following parameters are user-configurable strings. Refer to a full ASCII chart for more information. Grid For Virtual Wedge Grid, the first part of the bar code would be the following, which can include a string of up to 240 characters. Parameter information starts on page 328. *$+AF *$+AF Preamble For Virtual Wedge Preamble, the first part of the bar code would be below, followed by a string of up to 31 characters (no ) and an asterisk. Default is no characters. Parameter information is on page 326. *$+AD *$+AD Postamble For Virtual Wedge Postamble, the first part of the bar code would be below, followed by a string of up to 31 characters (no ) and an asterisk. Default is no characters. Parameter information is on page 327. *$+AE *$+AE 700 Series Color Mobile Computer User’s Manual 371 Appendix C — Bar Codes 372 700 Series Color Mobile Computer User’s Manual I Index The Classes and Functions Index covers classes and functions for the 700 Series Color Mobile Computer. The General Index covers all topics. Those in italics are figures, those in bold are tables. The Files Index is to assist you in locating descriptions for device drivers, applications, utilities, batch files, or other files within this publication. 700 Series Color Mobile Computer User’s Manual 373 Index Classes and Functions add_registry_section, [AddReg] flags, 244 registry_root_string, 244 value_name, 244 AddReg, [DefaultInstall], 240 [AddReg], add_registry_section flags, 244 registry_root_string, 244 value_name, 244 AddWep(), 103 AppName, [CEStrings], 237 BuildMax, [CEDevice], 238 BuildMin, [CEDevice], 238 CancelReadImage, IImage, 226 CancelReadRequest IADC, 152 IBarCodeReaderControl, 160 [CEDevice] BuildMax, 238 BuildMin, 238 ProcessorType, 238 UnsupportedPlatforms, 238 VersionMax, 238 VersionMin, 238 CESelfRegister, [DefaultInstall], 240 CESetupDLL, [DefaultInstall], 240 CEShortcuts, [DefaultInstall], 240 [CEShortcuts], shortcut_list_section shortcut_filename, 245 shortcut_type_flag, 245 target_file/path, 245 target_file_path, 245 CESignature [SourceDiskNames], 240 [Version], 236 [CEStrings] AppName, 237 InstallDir, 237 Close, IImage, 228 CloseHandle() DTR printing, 134, 135 IrDA printing, 128 NPCP printing, 129, 130 ConfigureProfile(), 106 ControlLED, IBarCodeReaderControl, 161 Copyfiles, [DefaultInstall], 240 [CopyFiles], file_list_section destination_filename, 243 flags, 243 source_filename, 243 create/delete ADC COM objects, 149 CreateEvent(), 283 374 CreateFile() DTR printing, 134, 135 IrDA printing, 128 NPCP printing, 129, 130 [DefaultInstall] AddReg, 240 CESelfRegister, 240 CESetupDLL, 240 CEShortcuts, 240 Copyfiles, 240 DeregisterDevice(), 129 DTR printing, 134 [DestinationDirs], file_list_section, 242 DeviceIOControl(), 98 DTR printing, 134 NPCP printing, 129 DeviceIoControl(), NPCP printing, 130, 131 disk_ordinal, [SourceDiskNames], 240 DllRegisterServer, 240 DllUnregisterServer, 240 EnableWep(), 105 EncryptWepKeyForRegistry(), 106 file_list_section [CopyFiles] destination_filename, 243 flags, 243 source_filename, 243 [DestinationDirs], 242 filename, [SourceDiskFiles], 241 GetAssociationStatus(), 104 GetAuthenticationMode(), 104 GetBSSID(), 101 GetCodabar, IS9CConfig, 173 GetCode11, IS9CConfig2, 205 GetCode128, IS9CConfig, 180 GetCode39, IS9CConfig, 176, 200 GetCode93, IS9CConfig, 179 GetConfig, ISCP, 217 GetCustomSymIds, IS9CConfig2, 207 GetGlobalAmble, IS9CConfig2, 211 GetI2of5, IS9CConfig, 183 GetLinkSpeed(), 102 GetMac(), 101 GetMatrix2of5, IS9CConfig, 185 GetMSI, IS9CConfig, 187 GetNetworkMode(), 103 GetNetworkType(), 102 GetPDF417, IS9CConfig, 188 GetPDF417Ext, IS9CConfig2, 213 GetPlessey, IS9CConfig, 192 GetPowerMode(), 105 GetRSSI(), 103 GetRTSThreshold(), 106 GetSSID(), 101 700 Series Color Mobile Computer User’s Manual Index GetStandard2of5, IS9CConfig, 194 GetSymIdXmit, IS9CConfig2, 214 GetTelepen, IS9CConfig, 197 GetTXPower(), 102 GetUpcEan, IS9CConfig, 198 GetWepStatus(), 104 IADC, 151 CancelReadRequest, 152 Initialize, 153 QueryAttribute, 154 QueryData, 155 Read, 156 SetAttribute, 157 IBARCODEREADER.H, IBarCodeReaderControl functions, 159 IBarCodeReaderControl, 159 CancelReadRequest, 160 ControlLED, 161 Initialize, 162 IssueBeep, 163 QueryAttribute, 164 Read, 165 SetAttribute, 167 TriggerScanner, 171 IImage CancelReadImage, 226 Close, 228 Open, 227 ReadImage, 225 ReadSigCapBuffer, 221 ReadSigCapFile, 224 Start, 226 Stop, 227 Imager, settings, IS9CConfig3, 216 Initialize IADC, 153 IBarCodeReaderControl, 162 InstallDir, [CEStrings], 237 IS9CConfig, 172 GetCodabar, 173 GetCode128, 180 GetCode39, 176, 200 GetCode93, 179 GetI2of5, 183 GetMatrix2of5, 185 GetMSI, 187 GetPDF417, 188 GetPlessey, 192 GetStandard2of5, 194 GetTelepen, 197 GetUpcEan, 198 SetCodabar, 174 SetCode128, 181 SetCode39, 177 SetCode93, 179 SetI2of5, 184 SetMatrix2of5, 186 700 Series Color Mobile Computer User’s Manual SetMSI, 187 SetPDF417, 189 SetPlessey, 192 SetStandard2of5, 195 SetTelepen, 197 IS9CConfig2, 204 GetCode11, 205 GetCustomSymIds, 207 GetGlobalAmble, 211 GetPDF417Ext, 213 GetSymIdXmit, 214 SetCode11, 205 SetCustomSymIds, 208 SetGlobalAmble, 212 SetPDF417Ext, 213 SetSymIdXmit, 214 IS9CConfig3, 216 ISCP GetConfig, 217 SetConfig, 218 isOrinoco(), 106 IssueBeep, IBarCodeReaderControl, 163 ITCDeviceClose, 150 ITCDeviceOpen, 140, 149 ITCUUID.LIB, IBarCodeReaderControl functions, 159 KernelIoControl(), 264 Open, IImage, 227 OSVERSIONINFO.dwBuildNumber, 238 OSVERSIONINFO.dwVersionMajor, 238 OSVERSIONINFO.dwVersionMinor, 238 ProcessorType, [CEDevice], 238 Provider, [Version], 236 QueryAttribute IADC, 154 IBarCodeReaderControl, 164 QueryData, IADC, 155 RadioConnect(), 101 RadioDisconnect(), 101 Read, 140 IADC, 156 IBarCodeReaderControl, 165 ReadFile(), NPCP printing, 129 ReadImage, IImage, 225 ReadSigCapBuffer, IImage, 221 ReadSigCapFile, IImage, 224 RegFlushKey(), 81, 262, 270 RegisterDevice(), 129 DTR printing, 134 RegOpenKeyEx(), 282 RegQueryValueEx(), 282 RegSetValueEx(), 282 375 Index SetAttribute IADC, 157 IBarCodeReaderControl, 167 SetAuthenticationMode(), 104 SetChannel(), 105 SetCodabar, IS9CConfig, 174 SetCode11, IS9CConfig2, 205 SetCode128, IS9CConfig, 181 SetCode39, IS9CConfig, 177 SetCode93, IS9CConfig, 179 SetConfig, ISCP, 218 SetCustomSymIds, IS9CConfig2, 208 SetGlobalAmble, IS9CConfig2, 212 SetI2of5, IS9CConfig, 184 SetMatrix2of5, IS9CConfig, 186 SetMSI, IS9CConfig, 187 SetNetworkMode(), 103 SetPDF417, IS9CConfig, 189 SetPDF417Ext, IS9CConfig2, 213 SetPlessey, IS9CConfig, 192 SetRTSThreshold(), 106 SetSSID(), 105 SetStandard2of5, IS9CConfig, 195 SetSymIdXmit, IS9CConfig2, 214 SetTelepen, IS9CConfig, 197 SHFullScreen(), 262, 263 shortcut_list_section, [CEShortcuts] shortcut_filename, 245 shortcut_type_flag, 245 target_file/path, 245 target_file_path, 245 376 Signature, [Version], 236 [SourceDiskFiles], filename, 241 [SourceDiskNames] CESignature, 240 disk_ordinal, 240 SourceDisksNames.MIPS, 241 SourceDisksNames.SH3, 241 Start, IImage, 226 StartScanList(), 107 Stop, IImage, 227 string_key, [Strings], 237 [Strings], string_key, 237 SYSTEMINFO.dwProcessorType, 238 Trigger settings, IS9CConfig3, 216 TriggerScanner, IBarCodeReaderControl, 171 UnsupportedPlatforms, [CEDevice], 238 [Version] CESignature, 236 Provider, 236 Signature, 236 VersionMax, [CEDevice], 238 VersionMin, [CEDevice], 238 WriteFile() DTR printing, 134, 135 IrDA printing, 128 NPCP printing, 129, 130 700 Series Color Mobile Computer User’s Manual Index General Index Numbers 1470 Imager. See Imager 1551/1553 Tethered Scanner. See Tethered scanner 1D laser scanner, about, 137 2D Imager about, 137 data collection features, 146 aimer LED, 146 scaled illumination LED, 146 window size and position, 146 image acquisition features, 147 overview, 146 4820 printer, NPCP driver, 129 6804DM printer DTR driver, 134 IrDA driver, 128 6804T printer DTR driver, 134 IrDA driver, 128 6805A printer DTR driver, 134 IrDA driver, 128 6806 printer DTR driver, 134 IrDA driver, 128 6808 printer DTR driver, 134 IrDA driver, 128 printer support, 127 681T printer, DTR driver, 134 6820 printer IrDA driver, 128 NPCP driver, 129 printer support, 127 6920 Communications Server, ManifestName parameter, 254 700 Platform Build, version number, 342 740 Color Computer, 281 781 printers DTR driver, 134 printer support, 127 782T printer, printer support, 127 802.11 CR radio CORE module, 107 802.11 WEP Encryption, profile security information, 91 802.11b antenna color code, 85 API, 100 channel, 89 communications setup, 87 configuration profiles, 100 CORE module, 107 network type, 89 profiles, 87 basic information, 89 certificates, 95 exporting, 96 700 Series Color Mobile Computer User’s Manual import/export, 96 importing, 97 read-only, 94 scan list, 97, 98 security information, 90 selected, 97 SSID (network name), 89 WEP encryption, 91 802.1x TLS, profile security information, 92 802.1x TTLS, profile security information, 93 Abstract Syntax Notation.1. See ASN.1 ActiveSync ActiveSync Help, 30 adding programs, 26 adding programs to Start menu, 28 Folder behavior connected to e-mail server, 46 installing applications, 77 Microsoft Reader, 58 Pocket Internet Explorer favorite links, 62 Mobile Favorites folder, 62 Pocket PC, 29 Pocket PC icon, 13 Pocket PC status icons, 12 URL, 29 ActiveX control tools, unit information control panel, CAB files, 345 AD command, with/without data, 326 ADC COM interfaces, 138 functions create/delete objects, 149 IADC, 151 IBarCodeReaderControl, 159 IS9CConfig, 172 IS9CConfig2, 204 IS9CConfig3, 216 Adding a profile, 88 Adding bookmarks, Microsoft Reader, 61 Adding drawings to text, Microsoft Reader, 61 Adding programs ActiveSync, 26 Pocket Internet Explorer, 27 Pocket PC, 26 to the Start menu, 28 via ActiveSync, 28 via File Explorer, 28 Adjusting settings, Pocket PC, 26 Adobe Acrobat Reader, URL, 116 AE command, with/without data, 327 Aimer LED duration, configuration parameter, 323 Alpha plane on keypad, 281 Annotations index, Microsoft Reader, 61 Antenna, radio type, 85 APIs 802.11b, 100 AT command interface, 115 IrSock, 128 Appointments, via Calendar, 31 377 Index APS linear imager, about, 137 ASCII printing, 128 printing to a port, port print method, 128 raw text to printer, 128 ASN.1, 125 Asset management, DeviceURL parameter, 253 AT command interface, 115 terminal application, 114 testing, 117 Attaching notes to text, Microsoft Reader, 61 Audio files, Windows Media Player, 57 Audio system external headset jack, 2 internal microphone, 2 speaker, 2 AutoCab, command line syntax, 82 AutoFTP, 260 AutoIP, 122 Automatic Data Collection. See ADC COM interfaces Automatic Private IP. See AutoIP Automatic shutoff bar code configuration, 369 configuration parameter, 355 Autostart FTP, 260 AvantGo channels, Pocket Internet Explorer, 64 AXCommunication, 345 AXFileTransfer, 345 AXReaderCommand, 345 AXVWedge, 345 Backlight timeout bar code configuration, 369 configuration parameter, 353 Bar Code scanning labels, 368 supported symbologies, 147, 289 symbologies, 360 Codabar, 362 Code 11, 363 Code 128, 364 Code 39, 363 Code 39 concatenation, 363 Code 39 full ASCII, 363 Code 93, 364 data string formats, 360 EAN, 362 I 2 of 5, 366 MSI code, 367 Plessey, 367 S 2 of 5, 366 UPC, 362 Bar code configuration audio volume, 368 automatic shutoff, 369 378 backlight timeout, 369 Code 39, 368 key clicks, 370 BARCODE_DATA_TYPE_ASCII, IBarCodeReaderControl::Read, 165 BARCODE_DATA_TYPE_UNICODE, IBarCodeReaderControl::Read, 165 BARCODE_DATA_TYPE_UNKNOWN, IBarCodeReaderControl::Read, 165 Battery low battery conditions, 3 Pocket PC status icons, 12 status, 2 Battery status, unit information control panel applet, 343 Beeper configuration parameter frequency, 320 volume, 318 silencing the volume, 319 supported functions, 317 Unit Manager, 349 when not available beeper frequency, 320 good read beep duration, 322 good read beeps, 321 biActualImageSize, pImgBuffer, IImage::ReadSigCapBuffer, 222 biBitCount, pImgBuffer, IImage::ReadSigCapBuffer, 222 biHeight, pImgBuffer, IImage::ReadSigCapBuffer, 222 biMaxImageBytes, pImgBuffer, IImage::ReadSigCapBuffer, 222 biWidth, pImgBuffer, IImage::ReadSigCapBuffer, 222 Block recognizer, Pocket PC input panel, 17 BlockSize, FTP Server, 252 Bluealps CORE module, 120 Bluetooth CORE module, 120 unit information control panel, main stack CAB file, 344 Bluetooth compatibility, network support, 120 Bluetooth Device Manager, documentation, 120 Books, Microsoft Reader adding bookmarks, 61 adding drawings, 61 annotations index, 61 attaching notes, 61 copying, 61 downloading, 58 highlighting, 61 reading, 60 removing, 61 searching, 61 Browing the Internet, Pocket Internet Explorer, 66 BTctrl program, documentation, 120 Build information, 5 byFNC1, IS9CConfig::SetCode128, 181 700 Series Color Mobile Computer User’s Manual Index CAB files after the extraction, 248 creating, 236 INF files, 236 with CAB Wizard, 249 information regarding, 4 installation functions, SETUP.DLL, 248 placing files onto storage card, 80 unit information control panel applet, 344 Cabinet Wizard creating CAB files, 249 troubleshooting, 250 using the application, 236 Cabling, scanner, 232 Calendar creating an appointment, 32 meeting requests, 33 Pocket Outlook, 31 Pocket PC icon, 13 scheduling a meeting, 33 using the summary screen, 33 Capacitor, internal super, 3 Capturing thoughts and ideas, via Notes, 40 Card support CompactFlash cards, 5 modems, 4 MultiMediaCards, 5 radios, 4 SecureDigital cards, 5 CDMA/1xRTT, 110 antenna color code, 85 AT command set, 116 CORE module, 111 CEImager location of the executable file, 80 migrating AUTORUN.DAT files, 80 Channel, 802.11 radio module, 89 ClassID field values VN_CLASS_ASIC, 266 VN_CLASS_BOOTSTRAP, 266 VN_CLASS_KBD, 266 Clock Pocket PC settings, 26 setting date and time, 358 Closing drivers, NPCP, 130 CMIP, 123 Codabar, 362 configuration parameter, 292 user ID, 310 default S9C settings, 175 enumerations, 175 IS9CConfig::GetCodabar, 173 IS9CConfig::SetCodabar, 174 modifier characters, 219 Code 11, 363 configuration parameter, 306 user ID, 314 700 Series Color Mobile Computer User’s Manual default S9C settings, 206 enumerations, 206 IS9CConfig2::GetCode11, 205 IS9CConfig2::SetCode11, 205 modifier characters, 219 Code 128, 364 configuration parameter, 295 FNC1 character, 297 user ID, 310 default S9C settings, 181 enumerations, 182 IImage::ReadSigCapBuffer, 223 IImage::ReadSigCapFile, 224 IS9CConfig::GetCode128, 180 IS9CConfig::SetCode128, 181 modifier characters, 219 Code 39, 363 configuration parameter, 290 user ID, 310 default S9C settings, 177 enumerations, 178 IImage::ReadSigCapBuffer, 223 IImage::ReadSigCapFile, 224 IS9CConfig::GetCode39, 176 IS9CConfig::SetCode39, 177 modifier characters, 219 Code 93, 364 configuration parameter, 294 length, 294 user ID, 311 default S9C settings, 179 enumerations, 180 IS9CConfig::GetCode93, 179 IS9CConfig::SetCode93, 179 modifier characters, 219 Code Division Multiple Access. See CDMA/1xRTT Codes 11, 363 128, 364 39, 363 39 concatenation, 363 39 full ASCII, 363 93, 364 Cold boot, IOCTL_HAL_COLDBOOT, 275 COM port configuration, 231 wedge settings, 231 COM1, NPCP parameter, 129 COM1 port, 128 Comm port wedge disabling, 231 enabling, 230 error messages, 232 limitations, 233 settings, 231 unit information control panel, 344 Command line syntax, AutoCab, 82 Common Object Resource Environment. See CORE 379 Index Communications DTR, 135 NPCP, 132 Communications options, 83 CompactFlash cards card support, 5 installing applications, 78 Composing Messages, via Inbox, 45 Computer shutdown, 3 Concatenation, 363 Configuration Management. See Unit Manager Configuration parameters aimer LED duration, 323 automatic shutoff, 355 backlight timeout, 353 beeper frequency, 320 volume, 318 codabar, 292 user ID, 310 code 11, 306 user ID, 314 code 128, 295 FNC1 character, 297 user ID, 310 code 39, 290 user ID, 310 code 93, 294 length, 294 user ID, 311 data matrix, 308 date/time, 352 EAN 13 user ID, 313 8 user ID, 313 good read beep duration, 322 beeps, 321 identification contact, 338 location, 340 name, 339 image dimension, 324 interleaved 2 of 5, 303 user ID, 311 key clicks, 354 macro PDF, 300 matrix 2 of 5, 304 user ID, 313 micro PDF 417, 302 MSI, 299 user ID, 311 PDF 417, 300 user ID, 311 plessey, 298 user ID, 312 prefix, 315 QR code, 307 380 security encryption key, 335 read encryption, 333 read-only community string, 331 read/write community string, 332 write encryption, 334 SNMP, security subnet mask, 309 standard 2 of 5, 291 user ID, 312 suffix, 316 telepen, 305 user ID, 313 trap authentication, 336 threshold, 337 UPC A user ID, 312 E user ID, 312 UPC/EAN, 293 virtual wedge, 325 code page, 329 grid, 328 postamble, 327 preamble, 326 volume, 356 Connecting directly to e-mail server, via Inbox, 42 Connecting to an ISP, 68 e-mail server, 72 work, 70 Connections See also Getting connected directly to e-mail server, 72 ending, 72 setting up an e-mail service, 73 status icon, 12 to an ISP, 68 via Ethernet, 69 via modem, 68 to work, 70 via Ethernet, 71 via modem, 70 via Ethernet to an ISP, 69 to work, 71 via modem to an ISP, 68 to work, 70 Contacts creating a contact, 34 finding a contact, 35 MSN Messenger chatting with, 55 working with, 54 Pocket Outlook, 34 Pocket PC icon, 13 using the summary screen, 36 700 Series Color Mobile Computer User’s Manual Index Control panel applets clock, 358 data collection, 288 beeper/LED, 317 imager, 323 symbologies, 289 symbology options, 309 virtual wedge, 325 power, battery status, 2 SNMP, 330 identification, 338 security, 331 traps, 336 system, wireless network, 87 unit information, 341 battery status, 3, 343 CAB files, 344 versions, 6, 342 utilities, 81 Converting writing to text, 20 Copying text, Microsoft Reader, 61 CORE, 84 802.11b radio module, 107 details, 109 general, 107 accessing from Programs panel, 84 Today screen, 84 Bluealps module, 120 Bluetooth, 120 module for 802.11b NIC, 100 WAN radio module, 111 details, 113 general, 111 Creating a modem connection to an ISP, 68 to work, 70 an Ethernet connection to an ISP, 69 to work, 71 appointment via Calendar, 32 CAB files, 236 with CAB Wizard, 249 contact via Contacts, 34 document via Pocket Word, 47 drawing via Notes, 22 INF files, 236 meeting requests, 33 note via Notes, 41 recording via Notes, 23 task via Tasks, 38 workbook via Pocket Excel, 52 Customer Support, xviii Data collection 2D imager features, 146 ADC COM interfaces, 138 build version number, 342 700 Series Color Mobile Computer User’s Manual configuration parameters aimer LED duration, 323 beeper frequency, 320 beeper volume, 318 codabar, 292 codabar user ID, 310 code 11, 306 code 11 user ID, 314 code 128, 295 code 128 FNC1 character, 297 code 128 user ID, 310 code 39, 290 code 39 user ID, 310 code 93, 294 code 93 length, 294 code 93 user ID, 311 data matrix, 308 EAN-13 user ID, 313 EAN-8 user ID, 313 good read beep duration, 322 good read beeps, 321 image dimension, 324 interleaved 2 of 5, 303 interleaved 2 of 5 user ID, 311 macro PDF, 300 matrix 2 of 5, 304 matrix 2 of 5 user ID, 313 micro PDF 417, 302 MSI, 299 MSI user ID, 311 PDF 417, 300 PDF 417 user ID, 311 plessey, 298 plessey user ID, 312 prefix, 315 QR code, 307 standard 2 of 5, 291 standard 2 of 5 user ID, 312 suffix, 316 telepen, 305 telepen user ID, 313 UPC-E user ID, 312 UPC-A user ID, 312 UPC/EAN, 293 virtual wedge, 325 virtual wedge code page, 329 virtual wedge grid, 328 virtual wedge postamble, 327 virtual wedge preamble, 326 functions create/delete ADC COM objects, 149 IADC, 151 IBarCodeReaderControl, 159 IS9CConfig, 172 IS9CConfig2, 204 IS9CConfig3, 216 initialization, 138 Unit Manager, 348 Data filtering, virtual wedge grid, 141 381 Index Data Matrix configuration parameter, 308 IS9CConfig3 function, 216 Date, setting, 358 Date/Time, configuration parameter, 352 Deleting a profile, 88 DeviceName, FTP Server, 253 DeviceURL, FTP Server, 253 DHCP, 122 Display full screen, 263 Docks, modem support, 4 DRAM, low battery shutdown, 3 Drawing mode, Pocket Word, 51 Drawing on the screen See also Notes Pocket Word, 51 Drivers DTR communications, 135 installing, 134 opening, 135 removing, 134 writing to, 135 NPCP closing, 130 communications, 132 I/O controls, 131 installing, 129 opening, 130 reading from, 130 removing, 129 writing to, 130 O’ Neil. See DTR printing DTR printing, 134 closing driver, 135 communications, 135 opening driver, 135 removing driver, 134 writing to driver, 135 dwAttrBufferSize IBarCodeReaderControl::QueryAttribute, 164 IBarCodeReaderControl::SetAttribute, 169 dwBufferSize IADC::QueryAttribute, 154 IS9CConfig2::GetGlobalAmble, 211 IS9CConfig2::SetGlobalAmble, 212 dwCommandBuffSize ISCP::GetConfig, 217 ISCP::SetConfig, 218 dwDataBufferSize IADC::Read, 156 IBarCodeReaderControl::Read, 165 dwLength IS9CConfig::SetCode128, 181 IS9CConfig::SetCode39, 177 IS9CConfig::SetCode93, 179 IS9CConfig::SetMatrix2of5, 186 IS9CConfig::SetMSI, 187 IS9CConfig::SetPlessey, 192 382 dwMaxNumElement, IS9CConfig2::GetCustomSymIds, 207 dwNextMessageSize, IADC::QueryData, 155 dwNumberOfBeeps, IBarCodeReaderControl::IssueBeep, 163 dwNumBytes IS9CConfig::SetCodabar, 174 IS9CConfig::SetI2of5, 184 IS9CConfig::SetStandard2of5, 195 dwNumElement, IS9CConfig2::SetCustomSymIds, 208 dwReplyBuffMaxSize ISCP::GetConfig, 217 ISCP::SetConfig, 218 dwStructSize pImgBuffer, IImage::ReadSigCapBuffer, 222 pSigCapSpec, IImage::ReadSigCapBuffer, 221 dwTimeout IADC::Read, 156 IBarCodeReaderControl::Read, 166 IImage::ReadImage, 225 dwTotalBufferedBytes, IADC::QueryData, 155 E-mail server getting connected, 72 setting up a service, 73 eAmbleId IS9CConfig2::GetGlobalAmble, 211 IS9CConfig2::SetGlobalAmble, 212 EAN, 362 configuration parameter, 293 13 user ID, 313 8 user ID, 313 default S9C settings, 181, 201 enumerations, 201 IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 modifier characters, 220 ean13Check IS9CConfig::GetUpcEan, 199 IS9CConfig::SetUpcEan, 200 ean13Select IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 ean8Check IS9CConfig::GetUpcEan, 199 IS9CConfig::SetUpcEan, 200 ean8Reencode IS9CConfig::GetUpcEan, 199 IS9CConfig::SetUpcEan, 200 ean8Select IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 eAttr IBarCodeReaderControl::QueryAttribute, 164 IBarCodeReaderControl::SetAttribute, 167 eAttribID IADC::QueryAttribute, 154 IADC::SetAttribute, 157 700 Series Color Mobile Computer User’s Manual Index eCheck IS9CConfig::SetCodabar, 174 IS9CConfig::SetI2of5, 184 IS9CConfig::SetMSI, 187 IS9CConfig::SetPlessey, 192 IS9CConfig::SetStandard2of5, 195 IS9CConfig2::SetCode11, 205 eCip128State, IS9CConfig::SetCode128, 181 eCLSI, IS9CConfig::SetCodabar, 174 eCode128, IS9CConfig2::SetPDF417Ext, 213 eDataType, IBarCodeReaderControl::Read, 165 eDecode IS9CConfig::SetCodabar, 174 IS9CConfig::SetCode128, 181 IS9CConfig::SetCode39, 177 IS9CConfig::SetCode93, 179 IS9CConfig::SetI2of5, 184 IS9CConfig::SetMatrix2of5, 186 IS9CConfig::SetMSI, 187 IS9CConfig::SetPlessey, 192 IS9CConfig::SetStandard2of5, 195 IS9CConfig::SetTelepen, 197 IS9CConfig2::SetCode11, 205 IS9CConfig2::SetPDF417Ext, 213 eDepth, pSigCapSpec, IImage::ReadSigCapBuffer, 222 eDeviceFlags IADC::Initialize, 153 IBarCodeReaderControl::Initialize, 162 ITCDeviceOpen, 149 Editing a profile, 88 Edition information, 8 eEan128Ident, IS9CConfig::SetCode128, 181 eFormat IImage::ReadImage, 225 IS9CConfig::SetCode39, 177 IS9CConfig::SetStandard2of5, 195 IS9CConfig::SetTelepen, 197 pImgBuffer, IImage::ReadSigCapBuffer, 222 pSigCapSpec, IImage::ReadSigCapBuffer, 222 eLED, IBarCodeReaderControl::ControlLED, 161 eLengthId IS9CConfig::SetCodabar, 174 IS9CConfig::SetI2of5, 184 IS9CConfig::SetStandard2of5, 195 eMacroPdf, IS9CConfig::SetPDF417, 189 Embedded modules, SB555, 110 Encoded Code 39 concatenation, 363 full ASCII, 363 Ending a connection, 72 Enumerations Codabar, 175 Code 11, 206 Code 128, 182 Code 39, 178 Code 93, 180 Interleaved 2 of 5, 185 Matrix 2 of 5, 186 MSI, 188 PDF 417, 190 700 Series Color Mobile Computer User’s Manual Plessey, 193 Standard 2 of 5, 196 Telepen, 198 UPC/EAN, 201 ePdf417Decode, IS9CConfig::SetPDF417, 189 ePdfAddressee, IS9CConfig::SetPDF417, 189 ePdfChecksum, IS9CConfig::SetPDF417, 189 ePdfControlHeader, IS9CConfig::SetPDF417, 189 ePdfFileName, IS9CConfig::SetPDF417, 189 ePdfFileSize, IS9CConfig::SetPDF417, 189 ePdfSegmentCount, IS9CConfig::SetPDF417, 189 ePdfSender, IS9CConfig::SetPDF417, 189 ePdfTimeStamp, IS9CConfig::SetPDF417, 189 Epson Escape Sequences, 128 Error messages comm port wedge, 232 tethered scanner, 232 ERROR_INSUFFICIENT_BUFFER IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 ERROR_INVALID_PARAMETER IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 eSS IS9CConfig::SetCodabar, 174 IS9CConfig::SetCode39, 177 eSSChars, IS9CConfig::SetCode39, 177 eSymbology, IBarCodeReaderControl::Read, 165 eSymIdXmit, IS9CConfig2::SetSymIdXmit, 214 Ethernet communications setup, 86 creating a connection to an ISP, 69 to work, 71 ETSI GSM 07.05 interface specifications, 115 ETSI GSM 07.07 interface specifications, 115 European Article Numbering code. See EAN eVer, IS9CConfig2::SetCode11, 205 Excel. See Pocket Excel Exporting a profile, 802.11 radio module, 96 Factory repair, xviii Favorite links, Pocket Internet Explorer, 62 File Explorer adding programs to Start menu, 28 Pocket PC, 25 removing programs, 28 File Transfer Protocol. See FTP Filter expression values, virtual wedge grid, 142 Find feature, Pocket PC, 25 fLedOn, IBarCodeReaderControl::ControlLED, 161 FlushBufferedData IADC::CancelReadRequest, 152 IBarCodeReaderControl::CancelReadRequest, 160 Folder behavior connected to e-mail server ActiveSync, 46 IMAP4, 46 POP3, 46 SMS, 46 383 Index FRAME_NOT_ACKED, 131 fScannerOn, IBarCodeReaderControl::TriggerScanner, 171 fSigCapEnable, IImage::Open, 227 FTP client, 256 configurable parameters, 252 BlockSize, 252 DeviceName, 253 DeviceURL, 253 IDNATarget, 254 ManifestName, 254 PauseAtStartup, 255 Root, 255 FTPDCMDS subdirectory, 259 heartbeat, 256 RTC 959, 259 server, 256 installing applications, 78 server requests CDUP, 256 CWD, 256 DELE, 256 HELP, 256 LIST, 256 MKD, 256 MODE, 256 NLST, 256 NOOP, 256 PASS, 256 PWD, 256 QUIT, 256 RETR, 256 RMD, 256 RNFR, 256 RNTO, 257 SITE, 257 SITE ATTRIB, 257 SITE BOOT, 258 SITE COPY, 258 SITE EXIT, 258 SITE HELP, 258 SITE KILL, 258 SITE LOG, 258 SITE PLIST, 258 SITE RUN, 258 SITE STATUS, 259 SITE TIMEOUT, 259 STOR, 257 SYST, 257 TYPE, 257 USER, 257 XCUP, 257 XCWD, 257 XMKD, 257 XPWD, 257 XRMD, 257 stopping server from application, 260 384 support, 256 web browsers, 259 FTPDCMDS subdirectory, FTP support, 259 Full screen display, 263 GDI approach, 128 General Packet Radio Service. See GSM/GPRS Getting connected directly to an e-mail server, 72 infrared (IR) port, 67 ISP, 67 Pocket PC, 67 setting up an e-mail service, 73 to an ISP, 68 creating a modem connection, 68 creating an Ethernet connection, 69 to work, 70 creating a modem connection, 70 creating an Ethernet connection, 71 transfer items using infrared, 67 Global services and support center, xviii Gold plane on keypad, 281 Good read, configuration parameter beep duration, 322 beeps, 321 Grid data configuration parameter, 328 filtering, 141 GSM/GPRS, 110 antenna color code, 85 AT command set GEM350X, 116 MC45, 116 CORE module, 111 HAL, verion of Pocket PC IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_OAL_VERINFO, 273 Header files IADC.H, IADC functions, 151 IBARCODEREADER.H, IBarCodeReaderControl functions, 159 IS9CCONFIG.H IS9CConfig functions, 172 IS9CConfig2 functions, 204 ITCDEVMGMT.H, 149 Headset jack, external, 2 Highlighting text, Microsoft Reader, 61 Hotmail account, 53 I 2 of 5. See Interleaved 2 of 5 I/O controls, NPCP driver, 131 iAspectRatio, pSigCapSpec, IImage::ReadSigCapBuffer, 221 700 Series Color Mobile Computer User’s Manual Index ID field values IOCTL_HAL_ITC_READ_PARM ITC_NVPARM_80211_INSTALLED, 268 ITC_NVPARM_80211_RADIOTYPE, 268 ITC_NVPARM_ANTENNA_DIVERSIT Y, 267 ITC_NVPARM_BLUETOOTH_INSTALLED, 268 ITC_NVPARM_CONTRAST, 266 ITC_NVPARM_DISPLAY_TYPE, 266 ITC_NVPARM_ECN, 266 ITC_NVPARM_EDBG_SUBNET, 266 ITC_NVPARM_EDG_IP, 266 ITC_NVPARM_ETHERNET_ID, 265 ITC_NVPARM_INTERMEC_DATACOLLECTION_HW, 267 ITC_NVPARM_INTERMEC_DATACOLLECTION_SW, 267 ITC_NVPARM_INTERMEC_SOFTWARE_CONTENT, 267 ITC_NVPARM_LAN9000_INSTALLED, 269 ITC_NVPARM_MANF_DATE, 265 ITC_NVPARM_MCODE, 266 ITC_NVPARM_RTC_RESTORE, 267 ITC_NVPARM_SERIAL_NUM, 265 ITC_NVPARM_SERIAL2_INSTALLED, 269 ITC_NVPARM_SERVICE_DATE, 266 ITC_NVPARM_SIM_PROTECT_HW_INSTALLED, 269 ITC_NVPARM_SIM_PROTECT_SW_INSTALLED, 269 ITC_NVPARM_VERSION_NUMBER, 266 ITC_NVPARM_VIBRATE_INSTALLED, 269 ITC_NVPARM_WAN_FREQUENCY, 268 ITC_NVPARM_WAN_INSTALLED, 268 ITC_NVPARM_WAN_RADIOTYPE, 268 ITC_NVPARM_WAN_RI, 267 IOCTL_HAL_ITC_WRITE_SYSPARM ITC_ DOCK_SWITCH, 270 ITC_ WAKEUP_MASK, 271 ITC_AMBIENT_FRONTLIGHT, 271 ITC_AMBIENT_KEYBOARD, 271 ITC_REGISTRY_LOCATION, 270 ITC_REGISTRY_SAVE_ENABLE, 270 Identification configuration parameter contact, 338 location, 340 name, 339 Unit Manager, 351 IDNA DeviceName, 253 DeviceURL, 253 IDNATarget, 254 ManifestName, 254 IDNATarget, FTP Server, 254 iid, ITCDeviceOpen, 149 IImage interface, 221 700 Series Color Mobile Computer User’s Manual Image, acquisition features, 147 Image dimension, configuration parameter, 324 Imager beeper functions not available beeper frequency, 320 good read beep duration, 322 good read beeps, 321 control panel appet, data collection, 323 data collection parameters aimer LED duration, 323 data matrix, 308 image dimension, 324 QR code, 307 settings, 232 supported beeper functions, 317 functions, 323 symbologies, 289 supported symbologies, 147 symbologies not available CIP 128 French Pharmaceutical, 296 Code 11, 306 Code 128 FNC1 character, 297 EAN 128 ]C1, 296 Macro PDF, 300 Matrix 2 of 5, 304 Micro PDF 417, 302 Telepen, 305 symbology user IDs not available Codabar, 310 Code 11, 314 Code 128, 310 Code 39, 310 Code 93, 311 EAN 13, 313 EAN 8, 313 Interleaved 2 of 5, 311 Matrix 2 of 5, 313 MSI, 311 PDF 417, 311 Plessey, 312 Standard 2 of 5, 312 Telepen, 313 UPC A, 312 UPC E, 312 Unit Manager, 350 IMAP4, Folder behavior connected to e-mail server, 46 Import libraries ITCDEVMGMT.LIB, 149 ITCUUID.LIB IADC functions, 151 IBarCodeReaderControl functions, 159 IS9CConfig functions, 172 IS9CConfig2 functions, 204 Importing a profile, 802.11 radio module, 97 385 Index Inbox composing messages, 45 connecting directly to e-mail server, 42 Folder behavior connected to e-mail server, 46 getting connected, 67 managing e-mail messages and folders, 46 Pocket Outlook, 42 Pocket PC icon, 13 synchronizing e-mail messages, 42 using a message list, 43 using My Text, 24 INF files, creating, 236 Infrared (IR) port Pocket PC, 67 transfer items using, 67 receiving information, 67 sending information, 67 Input panel block recognizer, 17 keyboard, 17 letter recognizer, 18 methods available, 16 Pocket PC, 14 Pocket Word, 49 selecting typed text, 18 transcriber, 18 word suggestions, 17 Installation, site, xviii Installation functions, SETUP.DLL, 248 Installing applications using a storage card, 78 using CompactFlash cards, 78 using SecureDigital cards, 79 with ActiveSync, 77 with Application Manager, 78 with FTP Server, 78 Installing drivers DTR, 134 NPCP, 129 Instant messaging, 53 Pocket PC icon, 12 Intelliget Bar Code Unit IImage::ReadSigCapBuffer, 223 IImage::ReadSigCapFile, 224 Interface specifications, ETSI GSM 07.0x, 115 Interleaved 2 of 5, 366 configuration parameter, 303 user ID, 311 default S9C settings, 184 enumerations, 185 IS9CConfig::GetI2of5, 183 IS9CConfig::SetI2of5, 184 modifier characters, 219 Intermec Device Network Announcement. See IDNA Internet Explorer. See Pocket Internet Explorer Internet explorer Pocket PC 2002 edition, 8 software build version, 5 Internet Service Provider. See ISP IOCTL_GET_CPU_ID, 280 386 IOCTL_HAL_COLDBOOT, 275, 280 IOCTL_HAL_GET_BOOT_DEVICE, 277 IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_DEVICE_INFO, 264 IOCTL_HAL_GET_DEVICEID, 272 IOCTL_HAL_GET_OAL_VERINFO, 273 IOCTL_HAL_GET_RESET_INFO, 276 IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 IOCTL_HAL_REBOOT, 278, 280 IOCTL_HAL_WARMBOOT, 275, 280 IOCTL_LOAD_NDIS_MINIPORT, 98 IOCTL_NPCP_BIND, 131 IOCTL_NPCP_CANCEL, 131 IOCTL_NPCP_CLOSE, 131 IOCTL_NPCP_ERROR, 131 IOCTL_NPCP_FLUSH, 131 IOCTL_PROCESSOR_INFORMATION, 279 IOCTL_UNLOAD_NDIS_MINIPORT, 98 iOffsetX, pSigCapSpec, IImage::ReadSigCapBuffer, 221 iOffsetY, pSigCapSpec, IImage::ReadSigCapBuffer, 222 IrDA printing, 128 iResolution, pSigCapSpec, IImage::ReadSigCapBuffer, 222 IS9CConfig3 Data Matrix symbology, 216 imager settings, 216 QRCode symbology, 216 trigger settings, 216 ISP connecting to via Pocket PC, 68 creating a modem connection, 68 an Ethernet connection, 69 Pocket Internet Explorer, 62 Pocket PC, 67 ITC_ DOCK_SWITCH, 270 ITC_ WAKEUP_MASK, 271 ITC_AMBIENT_FRONTLIGHT, 271 ITC_AMBIENT_KEYBOARD, 271 ITC_BARCODE_LASER_GOOD_READ_LED, IBarCodeReaderControl::ControlLED, 161 ITC_DEVID_80211RADIO_INTEL_2011B, 268 ITC_DEVID_80211RADIO_MAX values ITC_DEVID_80211RADIO_INTEL_2011B, 268 ITC_DEVID_80211RADIO_NONE, 268 ITC_DEVID_80211RADIO_NONE, 268 ITC_DEVID_INTERMEC2D_IMAGER, 267 ITC_DEVID_OEM2D_IMAGER, 267 ITC_DEVID_SCANHW_MAX values ITC_DEVID_INTERMEC2D_IMAGER, 267 ITC_DEVID_OEM2D_IMAGER, 267 ITC_DEVID_SCANHW_NONE, 267 ITC_DEVID_SE900_LASER, 267 ITC_DEVID_SE900HS_LASER, 267 ITC_DEVID_SCANHW_NONE, 267 ITC_DEVID_SE900_LASER, 267 ITC_DEVID_SE900HS_LASER, 267 ITC_DEVID_WANRADIO_NONE, 268 ITC_DEVID_WANRADIO_SIEMENS_MC45, 268 ITC_DEVID_WANRADIO_SIERRA_SB555, 268 700 Series Color Mobile Computer User’s Manual Index ITC_DEVID_WANRADIO_XIRCOM_GEM3503, 268 ITC_DHATTR_READFILTER IADC::SetAttribute, rgbData, 157 IBarCodeReaderControl::SetAttribute, 167 ITC_DHDEVFLAG_NODATA, ITCDeviceOpen, 149 ITC_DHDEVFLAG_READAHEAD IADC::Initialize, 153 IBarCodeReaderControl::Initialize, 162 ITCDeviceOpen, 149 ITC_FILE_OPEN_E, IImage::ReadSigCapFile, 224 ITC_IFTP_STOP, 260 ITC_IMGBUFF_TOO_SMALL_E IImage::ReadImage, 225 IImage::ReadSigCapBuffer, 223 ITC_INV_PARAMETER_E IImage::ReadImage, 225 IImage::ReadSigCapBuffer, 223 IImage::ReadSigCapFile, 224 ITC_KEYBOARD_CHANGE, CreateEvent(), 283 ITC_MAXFILTER_CHARS, IBarCodeReaderControl::SetAttribute, 167 ITC_MULTICLIENT_ENABLE, IADC::SetAttribute eAttribID, 157 rgbData, 157 ITC_NVPARM_80211_INSTALLED, 268 ITC_NVPARM_80211_RADIOTYPE, 268 ITC_NVPARM_ANTENNA_DIVERSIT Y, 267 ITC_NVPARM_BLUETOOTH_INSTALLED, 268 ITC_NVPARM_CONTRAST, 266 ITC_NVPARM_DISPLAY_TYPE, 266 ITC_NVPARM_ECN, 266 ITC_NVPARM_EDBG_SUBNET, 266 ITC_NVPARM_EDG_IP, 266 ITC_NVPARM_ETHERNET_ID, 265 ITC_NVPARM_INTERMEC_DATACOLLECTION_HW, 267 ITC_NVPARM_INTERMEC_DATACOLLECTION_SW, 267 ITC_NVPARM_INTERMEC_SOFTWARE_CONTENT, 267 ITC_NVPARM_LAN9000_INSTALLED, 269 ITC_NVPARM_MANF_DATE, 265 ITC_NVPARM_MCODE, 266 ITC_NVPARM_RTC_RESTORE, 267 ITC_NVPARM_SERIAL_NUM, 265 ITC_NVPARM_SERIAL2_INSTALLED, 269 ITC_NVPARM_SERVICE_DATE, 266 ITC_NVPARM_SIM_PROTECT_HW_INSTALLED, 269 ITC_NVPARM_SIM_PROTECT_SW_INSTALLED, 269 ITC_NVPARM_VERSION_NUMBER, 266 ITC_NVPARM_VIBRATE_INSTALLED, 269 ITC_NVPARM_WAN_FREQUENCY, 268 ITC_NVPARM_WAN_INSTALLED, 268 ITC_NVPARM_WAN_RADIOTYPE, 268 700 Series Color Mobile Computer User’s Manual ITC_NVPARM_WAN_RI, 267 ITC_RDRATTR_GOOD_READ_BEEP_DURATION, IBarCodeReaderControl::SetAttribute, 167 ITC_RDRATTR_GOOD_READ_BEEPS_NUMBER, IBarCodeReaderControl::SetAttribute, 167 ITC_RDRATTR_GOOD_READ_LED_ENABLE, IBarCodeReaderControl::SetAttribute, 167 ITC_RDRATTR_SCANNER_ENABLE, IBarCodeReaderControl::SetAttribute, 167 ITC_RDRATTR_TONE_ENABLE, IBarCodeReaderControl::SetAttribute, 167 ITC_RDRATTR_TONE_FREQUENCY, IBarCodeReaderControl::SetAttribute, 167 ITC_RDRATTR_VOLUME_LEVEL, IBarCodeReaderControl::SetAttribute, 167 ITC_REGISTRY_LOCATION, 270 ITC_REGISTRY_SAVE_ENABLE, 270 ITC_RESULT_ERR_BADREGION_E IImage::ReadSigCapBuffer, 223 IImage::ReadSigCapFile, 224 ITC_RESULT_NO_BC_DECODED_E IImage::ReadSigCapBuffer, 223 IImage::ReadSigCapFile, 224 ITC_TIMEOUT_E, IImage::ReadImage, 225 ITU-T interface specifications, 115 Keeping a to-do list, via Tasks, 37 KernelIoControl IOCTL_GET_CPU_ID, 280 IOCTL_HAL_COLDBOOT, 275, 280 IOCTL_HAL_GET_BOOT_DEVICE, 277 IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_DEVICE_INFO, 264 IOCTL_HAL_GET_DEVICEID, 272 IOCTL_HAL_GET_OAL_VERINFO, 273 IOCTL_HAL_GET_RESET_INFO, 276 IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 IOCTL_HAL_REBOOT, 278, 280 IOCTL_HAL_WARMBOOT, 275, 280 IOCTL_PROCESSOR_INFORMATION, 279 Key clicks bar code configuration, 370 configuration parameter, 354 Keyboard, Pocket PC input panel, 17 Keypad advanced remapping, 283 change notification, 283 driver registry settings, 282 planes, 281 remapping, 281 sample registry keys, 284 Knowledge Central, xviii 387 Index Laser scanner configuration parameters, 286 data collection parameters beeper frequency, 320 beeper volume, 318 codabar, 292 codabar user ID, 310 code 11, 306 code 11 user ID, 314 code 128, 295 code 128 FNC1 character, 297 code 128 user ID, 310 code 39, 290 code 39 user ID, 310 code 93, 294 code 93 length, 294 code 93 user ID, 311 EAN-13 user ID, 313 EAN-8 user ID, 313 good read beep duration, 322 good read beeps, 321 interleaved 2 of 5, 303 interleaved 2 of 5 user ID, 311 macro PDF, 300 matrix 2 of 5, 304 matrix 2 of 5 user ID, 313 micro PDF 417, 302 MSI, 299 MSI user ID, 311 PDF 417, 300 PDF 417 user ID, 311 plessey, 298 plessey user ID, 312 prefix, 315 standard 2 of 5, 291 standard 2 of 5 user ID, 312 suffix, 316 telepen, 305 telepen user ID, 313 UPC-E user ID, 312 UPC-A user ID, 312 UPC/EAN, 293 virtual wedge, 325 virtual wedge code page, 329 virtual wedge grid, 328 virtual wedge postamble, 327 virtual wedge preamble, 326 SNMP configuration parameters identification contact, 338 identification location, 340 identification name, 339 security encryption key, 335 security read encryption, 333 security read-only community string, 331 security read/write community string, 332 388 security subnet mask, 309 security write encryption, 334 trap authentication, 336 trap threshold, 337 supported beeper functions, 317 symbologies, 289 supported symbologies, 147 symbologies not available data matrix, 308 Datamatrix, 307 LEAP, 802.1x profile, security information, 93 Letter recognizer, Pocket PC input panel, 18 Library, Microsoft Reader, 59 Line printing, 128 lpBytesReturned IOCTL_GET_CPU_ID, 280 IOCTL_HAL_GET_BOOT_DEVICE, 277 IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_DEVICE_INFO, 264 IOCTL_HAL_GET_DEVICEID, 272 IOCTL_HAL_GET_OAL_VERINFO, 273 IOCTL_HAL_GET_RESET_INFO, 276 IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 IOCTL_PROCESSOR_INFORMATION, 279 lpInBuf IOCTL_GET_CPU_ID, 280 IOCTL_HAL_COLDBOOT, 275 IOCTL_HAL_GET_BOOT_DEVICE, 277 IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_DEVICE_INFO, 264 IOCTL_HAL_GET_DEVICEID, 272 IOCTL_HAL_GET_OAL_VERINFO, 273 IOCTL_HAL_GET_RESET_INFO, 276 IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 IOCTL_HAL_REBOOT, 278 IOCTL_HAL_WARMBOOT, 275 IOCTL_PROCESSOR_INFORMATION, 279 lpInBufSize IOCTL_GET_CPU_ID, 280 IOCTL_HAL_COLDBOOT, 275 IOCTL_HAL_GET_BOOT_DEVICE, 277 IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_DEVICE_INFO, 264 IOCTL_HAL_GET_DEVICEID, 272 IOCTL_HAL_GET_OAL_VERINFO, 273 IOCTL_HAL_GET_RESET_INFO, 276 IOCTL_HAL_REBOOT, 278 IOCTL_HAL_WARMBOOT, 275 IOCTL_PROCESSOR_INFORMATION, 279 700 Series Color Mobile Computer User’s Manual Index lpOutBuf IOCTL_GET_CPU_ID, 280 IOCTL_HAL_COLDBOOT, 275 IOCTL_HAL_GET_BOOT_DEVICE, 277 IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_DEVICE_INFO, 264 IOCTL_HAL_GET_DEVICEID, 272 IOCTL_HAL_GET_OAL_VERINFO, 273 IOCTL_HAL_GET_RESET_INFO, 276 IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 IOCTL_HAL_REBOOT, 278 IOCTL_HAL_WARMBOOT, 275 IOCTL_PROCESSOR_INFORMATION, 279 LPT9 printer device, 129 Macro PDF, configuration parameter, 300 Managing e-mail messages and folders, via Inbox, 46 ManifestName, FTP Server, 254 Matrix 2 of 5 configuration parameter, 304 user ID, 313 default S9C settings, 186 enumerations, 186 IS9CConfig::GetMatrix2of5, 185 IS9CConfig::SetMatrix2of5, 186 modifier characters, 219 Meetings, via Calendar, 31 Menus, Pocket PC settings, 26 MIBs ASN.1, 125 files, 125 object identifier, 126 OIDs, 126 Micro PDF 417, configuration parameter, 302 Microphone, internal, 2 Microsoft Developer Network Library. See MSDN library Microsoft Exchange e-mail account, 53 Microsoft Passport account, 53 Microsoft Reader books downloading, 58 reading, 60 removing, 61 features, 61 adding bookmarks, 61 adding drawings, 61 annotations index, 61 attaching notes, 61 copying text, 61 highlighting text, 61 searching for text, 61 Pocket PC, 58 using the library, 59 Microsoft Word. See Pocket Word Migrating applications, 80 Mini-Landline modems, 4 Mobile Favorites folder, Pocket Internet Explorer, 62 700 Series Color Mobile Computer User’s Manual Modems card support, 4 creating a connection to an ISP, 68 to work, 70 MP3 files, Windows Media Player, 57 MSDN library, 260 MSI, 367 configuration parameter, 299 user ID, 311 default S9C settings, 187 enumerations, 188 IS9CConfig::GetMSI, 187 IS9CConfig::SetMSI, 187 modifier characters, 219 MSN account, 53 MSN Messenger about, 53 accounts Hotmail, 53 Microsoft Exchange e-mail, 53 Microsoft Passport, 53 MSN, 53 contacts chatting with, 55 working with, 54 Pocket PC icon, 13 setting up, 54 using My Text, 24 MultiMediaCards, card support, 5 nBufferSize, IADC::SetAttribute, 157 nDepth, IImage::ReadImage, 225 NDIS_NET_AUTO_UNKNOWN, GetNetworkMode(), 103 NDIS_NET_MODE_ESS, GetNetworkMode(), 103 NDIS_NET_MODE_IBSS, GetNetworkMode(), 103 NDIS_NET_MODE_UNKNOWN, GetNetworkMode(), 103 NDIS_NET_TYPE_DS, GetNetworkType(), 102 NDIS_NET_TYPE_FH, GetNetworkType(), 102 NDIS_NET_TYPE_UNDEFINED, GetNetworkType(), 102 NDIS_POWER_LEVEL_1, GetTXPower(), 102 NDIS_POWER_LEVEL_15, GetTXPower(), 102 NDIS_POWER_LEVEL_30, GetTXPower(), 102 NDIS_POWER_LEVEL_5, GetTXPower(), 102 NDIS_POWER_LEVEL_63, GetTXPower(), 102 NDIS_POWER_LEVEL_UNKNOWN, GetTXPower(), 102 NDIS_RADIO_ASSOCIATED, GetAssocationStatus(), 104 NDIS_RADIO_AUTH_MODE_AUTO, GetAuthenticationMode(), 104 NDIS_RADIO_AUTH_MODE_ERROR, GetAuthenticationMode(), 104 NDIS_RADIO_AUTH_MODE_OPEN, GetAuthenticationMode(), 104 389 Index NDIS_RADIO_AUTH_MODE_SHARED, GetAuthenticationMode(), 104 NDIS_RADIO_POWER_MODE_CAM, GetPowerMode(), 105 NDIS_RADIO_POWER_MODE_MAX, GetPowerMode(), 105 NDIS_RADIO_POWER_MODE_PSP, GetPowerMode(), 105 NDIS_RADIO_POWER_UNKNOWN, GetPowerMode(), 105 NDIS_RADIO_SCANNING, GetAssociationStatus(), 104 NDIS_RADIO_WEP_ABSENT, GetWepStatus, 104 NDIS_RADIO_WEP_DISABLED, GetWepStatus(), 104 NDIS_RADIO_WEP_ENABLED, GetWepStatus(), 104 NDIS_RADIO_WEP_NOT_SUPPORTED, GetWepStatus(), 104 Network adapters 802.11b, 87 antenna color code, 85 Ethernet communications, 86 wireless printing, 120 WWAN radio options, 110 Network management. See SNMP Network type, 802.11 radio module, 89 nFilterChars IADC::SetAttribute, 157 IBarCodeReaderControl::SetAttribute, 167 nInBufSize IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 Notes creating a note, 41 drawing on the screen, 22 creating a drawing, 22 selecting a drawing, 22 Pocket Outlook, 40 Pocket PC icon, 13 recording a message, 23 creating a recording, 23 writing on the screen, 19 alternate writing, 21 converting writing to text, 20 selecting the writing, 19 tips for good recognition, 21 nOutBufSize IOCTL_GET_CPU_ID, 280 IOCTL_HAL_COLDBOOT, 275 IOCTL_HAL_GET_BOOT_DEVICE, 277 IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_DEVICE_INFO, 264 IOCTL_HAL_GET_DEVICEID, 272 IOCTL_HAL_GET_OAL_VERINFO, 273 IOCTL_HAL_GET_RESET_INFO, 276 IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 IOCTL_HAL_REBOOT, 278 390 IOCTL_HAL_WARMBOOT, 275 IOCTL_PROCESSOR_INFORMATION, 279 NPCP printing, 129 about, 129 closing driver, 130 COM1 parameters, 129 communications, 132 driver I/O controls, 131 installation, 129 LPT9, 129 opening driver, 130 reading from driver, 130 removal, 129 sample code, 132 unit information control panel, NPCPTEST CAB file, 344 writing to driver, 130 O’ Neil printing See also DTR printer installing driver, 134 Object store IOCTL_HAL_COLDBOOT, 275 IOCTL_HAL_REBOOT, 278 IOCTL_HAL_WARMBOOT, 275 Oldstyle device ID, 272 Onsite repair, xviii Opening drivers DTR, 135 NPCP, 130 Operators, virtual wedge grid, 144 Other publications, xviii Owner information, Pocket PC settings, 26 Page format printing, 128 Password Pocket Excel, 53 Pocket PC settings, 26 PauseAtStartup, FTP Server, 255 pBarCodeDataDetails, IBarCodeReaderControl::Read, 165 pbyFNC1, IS9CConfig::GetCode128, 180 PDF 417 about the laser scanner, 137 configuration parameter, 300 user ID, 311 default S9C settings, 190 enumerations, 190 extensions IS9CConfig2::GetPDF417ext, 213 IS9CConfig2::SetPDF417ext, 213 IImage::ReadSigCapBuffer, 223 IImage::ReadSigCapFile, 224 IS9CConfig::GetPDF417, 188 IS9CConfig::SetPDF417, 189 modifier characters, 220 pdwBufferSize, IS9CConfig2::GetGlobalAmble, 211 700 Series Color Mobile Computer User’s Manual Index pdwLength IS9CConfig::GetCode128, 180 IS9CConfig::GetCode93, 179 IS9CConfig::GetMatrix2of5, 185 IS9CConfig::GetMSI, 187 IS9CConfig::GetPlessey, 192 pdwNumBytes IS9CConfig::GetCodabar, 173 IS9CConfig::GetI2of5, 183 IS9CConfig::GetStandard2of5, 194 pdwNumElement, IS9CConfig2::GetCustomSymIds, 207 pdwReplyBuffSize ISCP::GetConfig, 217 ISCP::SetConfig, 218 pdwTotalDiscardedBytes, IADC::CancelReadRequest, 152 peCheck IS9CConfig::GetCodabar, 173 IS9CConfig::GetCode39, 176 IS9CConfig::GetI2of5, 183 IS9CConfig::GetMSI, 187 IS9CConfig::GetPlessey, 192 IS9CConfig::GetStandard2of5, 194 IS9CConfig2::GetCode11, 205 peCip128State, IS9CConfig::GetCode128, 180 peCLSI, IS9CConfig::GetCodabar, 173 peCode128, IS9CConfig2::GetPDF417Ext, 213 peDecode IS9CConfig::GetCodabar, 173 IS9CConfig::GetCode128, 180 IS9CConfig::GetCode39, 176 IS9CConfig::GetCode93, 179 IS9CConfig::GetI2of5, 183 IS9CConfig::GetMatrix2of5, 185 IS9CConfig::GetMSI, 187 IS9CConfig::GetPlessey, 192 IS9CConfig::GetStandard2of5, 194 IS9CConfig::GetTelepen, 197 IS9CConfig2::GetCode11, 205 IS9CConfig2::GetPDF417Ext, 213 peEan128Ident, IS9CConfig::GetCode128, 180 peFormat IS9CConfig::GetCode39, 176 IS9CConfig::GetStandard2of5, 194 IS9CConfig::GetTelepen, 197 peLengthId IS9CConfig::GetCodabar, 173 IS9CConfig::GetI2of5, 183 IS9CConfig::GetStandard2of5, 194 peMacroPdf, IS9CConfig::GetPDF417, 188 700 Series Color Mobile Computer User’s Manual pePdf417Decode, IS9CConfig::GetPDF417, 188 pePdfAddressee, IS9CConfig::GetPDF417, 189 pePdfChecksum, IS9CConfig::GetPDF417, 189 pePdfControlHeader, IS9CConfig::GetPDF417, 188 pePdfFileName, IS9CConfig::GetPDF417, 188 pePdfFileSize, IS9CConfig::GetPDF417, 189 pePdfSegmentCount, IS9CConfig::GetPDF417, 188 pePdfSender, IS9CConfig::GetPDF417, 189 pePdfTimeStamp, IS9CConfig::GetPDF417, 188 peSS IS9CConfig::GetCodabar, 173 IS9CConfig::GetCode39, 176 peSSChars, IS9CConfig::GetCode39, 176 peSymIdXmit, IS9CConfig2::GetSymIdXmit, 214 peVer, IS9CConfig2::GetCode11, 205 pImgBuffer IImage::ReadImage, 225 IImage::ReadSigCapBuffer, 222 Planes, keypad, 281 Plessey, 367 configuration parameter, 298 user ID, 312 default S9C settings, 193 enumerations, 193 IS9CConfig::GetPlessey, 192 IS9CConfig::SetPlessey, 192 modifier characters, 220 pnBufferData, IADC::QueryAttribute, 154 pnBytesReturned IADC::Read, 156 IBarCodeReaderControl::Read, 165 Pocket Excel about, 52 creating a workbook, 52 Pocket PC icon, 13 Pocket Internet Explorer about, 62 adding programs, 27 AvantGo channels, 64 browing the Internet, 66 favorite links, 62 getting connected, 67 Mobile Favorites folder, 62 Pocket PC icon, 13 software build, 5 viewing mobile favorites and channels, 66 Pocket Outlook, 31 Calendar, 31 391 Index Pocket PC about, 8 ActiveSync, 29 basic skills, 11 Calendar, 31 command bar, 14 Contacts, 34 edition information, 8 getting connected, 67 Inbox, 42 input panel. See Input panel IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_OAL_VERINFO, 273 MSN Messenger, 53 navigation bar, 14 Notes, 40 notifications, 15 status icon, 12 Pocket Excel, 52 Pocket Word, 47 pop-up menus, 15 programs, 13 status icons, 12 support URLs, 10 Tasks, 37 Today screen, 11 where to find information, 10 Windows Media Player, 57 writing on the screen, 19 Pocket Word about, 47 creating a document, 47 drawing mode, 51 Pocket PC icon, 13 recording mode, 51 tips, 53 typing mode, 49 writing mode, 50 POP3, Folder behavior connected to e-mail server, 46 Postamble configuration parameter, 327 with/without data, 327 Power control panel, battery status, 2 Pocket PC settings, 26 ppvObject ITCDeviceClose, 150 ITCDeviceOpen, 149 Preamble configuration parameter, 326 with/without data, 326 Prefix, configuration parameter, user ID, 315 Printer support, 128 IrDA printer driver, 128 NPCP printer driver, 129 392 O’ Neil printer driver, 134 Processor information, IOCTL_PROCESSOR_INFORMATION, 279 Profiles 802.11 radio module, 87 basic information, 89 certificates, 95 import/export, 96 read-only, 94 scan list, 97 security information, 90 adding to unit, 88 deleting, 88 editing, 88 Programs, adding or removing, Pocket PC, 26 pSigCapSpec IImage::ReadSigCapBuffer, 221 IImage::ReadSigCapFile, 224 pStructSymIdPair IS9CConfig2::GetCustomSymIds, 207 IS9CConfig2::SetCustomSymIds, 208 pSystemTime, IADC::Read, 156 pszDevice, ITCDeviceOpen, 149 pszDeviceName IADC::Initialize, 153 IBarCodeReaderControl::Initialize, 162 pszFileName, IImage::ReadSigCapFile, 224 pwLength, IS9CConfig::GetCode39, 176 pwTotalDiscardedBytes, IBarCodeReaderControl::CancelReadRequest, 160 pwTotalDiscardedMessages IADC::CancelReadRequest, 152 IBarCodeReaderControl::CancelReadRequest, 160 QR code configuration parameter, 307 IS9CConfig3 function, 216 Quick Response code. See QR code Radios See also Network adapters card support, 4 Reader commands, 357 configuration change, 357 date and time settings, 358 Reading from drivers, NPCP, 130 Reboot methods IOCTL_HAL_COLDBOOT, 280 IOCTL_HAL_REBOOT, 280 IOCTL_HAL_WARMBOOT, 280 Record button, recording a message, 23 Recording a message See also Notes Pocket Word, 51 Recording mode, Pocket Word, 51 700 Series Color Mobile Computer User’s Manual Index Recovery CD AutoCab method, 82 AutoRun system, 76 AUTOUSER.DAT file, 81 part numbers, xviii RegFlushKey() API, 262 S9C upgrade, 345 updating the system software, 79 RegFlush utility, 81 Registry FTP Server parameters, 252 keypad remapping, 282 sample view of key mapping, 284 save location, IOCTL_HAL_ITC_WRITE_SYSPARM, 270 writing to a storage card, 81 Registry settings AutoCfg, 122 AutoFTP, 261 AutoInterval, 122 AutoIP/DHCP, 122 DhcpMaxRetry, 122 DhcpRetryDialogue, 122 EnableDHCP, 122 keypad driver, 282 keypad planes alpha, 282 gold, 282 unshifted, 282 Related publications, xviii Removeable card support, 5 Removing drivers DTR, 134 NPCP, 129 Removing programs, Pocket PC, 26, 28 RFC 959, 259 rgbAttrBuffer IBarCodeReaderControl::QueryAttribute, 164 IBarCodeReaderControl::SetAttribute, 168 rgbBuffer IADC::QueryAttribute, 154 IS9CConfig2::GetGlobalAmble, 211 IS9CConfig2::SetGlobalAmble, 212 rgbCommandBuff ISCP::GetConfig, 217 ISCP::SetConfig, 218 rgbData, IADC::SetAttribute, 157 rgbDataBuffer IADC::Read, 156 IBarCodeReaderControl::Read, 165 rgBeepRequests, IBarCodeReaderControl::IssueBeep, 163 rgbImageData, pImgBuffer, IImage::ReadSigCapBuffer, 222 rgbLengthBuff IS9CConfig::GetCodabar, 173 IS9CConfig::GetI2of5, 183 IS9CConfig::GetStandard2of5, 194 IS9CConfig::SetCodabar, 174 700 Series Color Mobile Computer User’s Manual IS9CConfig::SetI2of5, 184 IS9CConfig::SetStandard2of5, 195 rgbReplyBuff ISCP::GetConfig, 217 ISCP::SetConfig, 218 Root, FTP Server, 255 S 2 of 5. See Standard 2 of 5 S_DEVICE_CONTENTION_E, IImage::Open, 227 S_DEVICE_NOT_OPENED_E IImage::CancelReadImage, 226 IImage::Close, 228 IImage::ReadImage, 225 IImage::ReadSigCapBuffer, 223 IImage::ReadSigCapFile, 224 IImage::Start, 226 IImage::Stop, 227 S_IMG_NOT_PRESENT_E IImage::Open, 227 IImage::Stop, 227 S_OK IImage::CancelReadImage, 226 IImage::Close, 228 IImage::Open, 227 IImage::ReadImage, 225 IImage::ReadSigCapBuffer, 223 IImage::ReadSigCapFile, 224 IImage::Start, 226 IImage::Stop, 227 S9C initialization, 138 IS9CConfig functions, 172 IS9CConfig2 functions, 204 IS9CConfig3 functions, 216 unit information control panel, upgrade files, 345 version number, 342 Sabre 1551E or 1553 See also Tethered scanner cabling, 232 settings, 232 Sample code, NPCP printing, 132 SB555 radio, 110 Scan list of profiles, 802.11 radio module, 98 Scanner, unit configuration parameters automatic shutoff, 355 backlight timeout, 353 date/time, 352 key clicks, 354 volume, 356 Scanner cabling, 232 Scheduling appointments and meetings, via Calendar, 31 SDK, unit information control panel, 345 SDMMC Disk, 80 Searching for text, Microsoft Reader, 61 SecureDigital cards card support, 5 installing applications, 78, 79 393 Index Security configuration parameter encryption key, 335 read encryption, 333 read-only community string, 331 read/write community string, 332 subnet mask, 309 write encryption, 334 Unit Manager, 350 Selected profile, 802.11 radio module, 97 Selecting, drawing via Notes, 22 Sending and receiving messages, via Inbox, 42 Serial port, modem support, 4 Service contract status, xviii Setting date and time, 358 Setting up an e-mail service, 73 SETUP.DLL, installation functions, 248 Signature capture IImage interface, 221 IImage::CancelReadImage, 226 IImage::Close, 228 IImage::Open, 227 IImage::ReadImage, 225 IImage::ReadSigCapBuffer, 221 IImage::ReadSigCapFile, 224 IImage::Start, 226 IImage::Stop, 227 Simple Network Management Protocol. See SNMP Site installations, xviii Site surveys, xviii SMS, Folder behavior connected to e-mail server, 46 SNMP, 125 about SNMP, 123 CMIP, 123 configuration parameters identification contact, 338 identification location, 340 identification name, 339 security encryption key, 335 security read encryption, 333 security read-only community string, 331 security read/write community string, 332 security subnet mask, 309 security write encryption, 334 trap authentication, 336 trap threshold, 337 control primitives, 123 multiple retrievals, 124 retrieval, 124 Unit Manager, 350 using the protocol, 123 SNMP OIDs aimer LED duration, 323 automatic shutoff, 355 backlight timeout, 353 beeper frequency, 320 volume, 318 codabar, 292 user ID, 310 394 code 11, 306 user ID, 314 code 128, 295 FNC1 character, 297 user ID, 310 code 39, 290 user ID, 310 code 93, 294 length, 294 user ID, 311 data matrix, 308 date/time, 352 default S9C settings, 210 EAN 13 user ID, 313 8 user ID, 313 good read beep duration, 322 beeps, 321 identification contact, 338 location, 340 name, 339 image dimension, 324 interleaved 2 of 5, 303 user ID, 311 IS9CConfig2::GetCustomSymIds, 207 IS9CConfig2::GetSymIdXmit, 214 IS9CConfig2::SetCustomSymIds, 208 IS9CConfig2::SetSymIdXmit, 214 key clicks, 354 macro PDF, 300 matrix 2 of 5, 304 user ID, 313 micro PDF 417, 302 MSI, 299 user ID, 311 PDF 417, 300 user ID, 311 plessey, 298 user ID, 312 prefix, 315 QR code, 307 security encryption key, 335 read encryption, 333 read-only community string, 331 read/write community string, 332 write encryption, 334 security subnet mask, 309 standard 2 of 5, 291 user ID, 312 suffix, 316 telepen, 305 user ID, 313 transmission option, 215 trap authentication, 336 threshold, 337 700 Series Color Mobile Computer User’s Manual Index UPC A user ID, 312 E user ID, 312 UPC/EAN, 293 virtual wedge, 325 code page, 329 grid, 328 postamble, 327 preamble, 326 volume, 356 Symbology ID defaults, 219 Software Developer’ s Kit. See SDK Software Tools CD. See Tools CD Software versions, 6, 342 700 Series Computer, 5 unit information control panel applet, 342, 344 Speaker, 2 SSID (network name), 802.11 radio module, 89 Standard 2 of 5, 366 configuration parameter, 291 user ID, 312 default S9C settings, 196 enumerations, 196 IS9CConfig::GetStandard2of5, 194 IS9CConfig::SetStandard2of5, 195 modifier characters, 220 Start Menu, adding programs, 28 via ActiveSync, 28 via File Explorer, 28 Status icons, Pocket PC, 12 Stream device driver NPCPPORT.DLL, 129 ONEIL.DLL, 134 stTimeStamp, IBarCodeReaderControl::Read, 165 Suffix, configuration parameter, 316 Summary screen Calendar, 33 Contacts, 36 Tasks, 39 Support global services and support center, xviii web, xviii Symbologies, 360 scanning labels, 368 Unit Manager, 348 user IDs Codabar, 310 Code 11, 314 Code 128, 310 Code 39, 310 Code 93, 311 EAN 13, 313 EAN 8, 313 Interleaved 2 of 5, 311 Matrix 2 of 5, 313 MSI, 311 PDF 417, 311 Plessey, 312 Standard 2 of 5, 312 Telepen, 313 700 Series Color Mobile Computer User’s Manual UPC A, 312 UPC E, 312 when not available imager, 298, 299, 300, 302, 304, 305, 306 laser scanner, 307, 308 Symbology ID, Unit Manager, 349 Synchronizing e-mail messages, via Inbox, 42 System status maintained, 4 szDest, EncryptWepKeyForRegistry(), 106 szFilter IADC::SetAttribute, 157 IBarCodeReaderControl::SetAttribute, 167 szSource, EncrypWepKeyForRegistry(), 106 Tasks creating a task, 38 Pocket Outlook, 37 Pocket PC icon, 13 using the summary screen, 39 TCP/IP client, DHCP server, 122 Technical support, xviii Telepen configuration parameter, 305 user ID, 313 default S9C settings, 197 enumerations, 198 IS9CConfig::GetTelepen, 197 IS9CConfig::SetTelepen, 197 modifier characters, 220 Telephone numbers, xviii Testing AT commands, 117 Tethered scanner capabilities, 233 disabling, 231 enabling, 231 error messages, 232 limitations, 233 settings, 231 Text messages, Pocket PC, 24 Time, setting, 358 Tips for working, Pocket Excel, 53 TLS, 802.1x profile, 92 Today, Pocket PC settings, 26 Today screen, Pocket PC, 11 Tools CD base operating system files, 78 Bluetooth documentation, 120 CAB files, 4, 78, 344 CE Imager, 80 Comm Port Wedge CAB file, 344 management tools installed on desktop, 77 MIB files, 125 part number, xviii sample NPCP code, 132 SRDEVMGMT.CAB file, 286 Unit Manager CAB file, 347 Wireless Printing Development Guide, 120 wireless printing sample, 345 wireless printing SDK, 120 395 Index Tracking people, via Contacts, 34 Transcriber, Pocket PC input panel, 18 Transfer items using infrared getting connected, 67 receiving information, 67 sending information, 67 Trap configuration parameters authentication, 336 threshold, 337 Traps control panel appet, SNMP, 336 Unit Manager, 351 Troubleshooting, CAB Wizard, 250 TTLS, 802.1x profile, 93 Typing mode, Pocket Word, 49 Typing on the screen, Pocket Word, 49 UDP FTPDCE, 256 within SNMP, 123 UDP broadcasts, IDNATarget parameter, 254 uiHeight, pSigCapSpec, IImage::ReadSigCapBuffer, 222 uiWidth, pSigCapSpec, IImage::ReadSigCapBuffer, 222 Unit, configuration parameters automatic shutoff, 355 backlight timeout, 353 date/time, 352 key clicks, 354 volume, 356 Unit information battery status, 343 CAB files, 344 ActiveX control tools, 345 Bluetooth stack, 344 Comm Port Wedge, 344 NPCP printer, 344 S9C Upgrade, 345 SDK, 345 Unit Manager, 345 Unit Manager help, 345 Windows configuration, 345 wireless printing demo, 345 wireless printing sample, 345 versions, 6, 342 700 Platform Build, 342 DataCollection Build, 342 S9C, 342 Unit Manager automatic shutoff, 355 backlight timeout, 353 data collection, 348 beeper/LED, 349 imager, 350 symbologies, 348 symbology ID, 349 virtual wedge, 350 date/time, 352 documentation, 347 key clicks, 354 396 reader commands, 357 changing configuration, 357 setting time and date, 358 SNMP, 350 identification, 351 security, 350 traps, 351 volume, 356 Unit manager installing applications, 78 unit information control panel, 345 help files, 345 Universal Product Code. See UPC Unshifted plane on keypad, 281 UPC, 362 configuration parameter, 293 A user ID, 312 E user ID, 312 default S9C settings, 201 enumerations, 201 IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 modifier characters, 220 upcACheck IS9CConfig::GetUpcEan, 199 IS9CConfig::SetUpcEan, 200 upcAddOn2 IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 upcAddOn5 IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 upcAddOnDigits IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 upcANumSystem IS9CConfig::GetUpcEan, 199 IS9CConfig::SetUpcEan, 200 upcAReencode IS9CConfig::GetUpcEan, 199 IS9CConfig::SetUpcEan, 200 upcASelect IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 upceanDecode IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 upcECheck IS9CConfig::GetUpcEan, 199 IS9CConfig::SetUpcEan, 200 upcENumSystem IS9CConfig::GetUpcEan, 199 IS9CConfig::SetUpcEan, 200 upcEReencode IS9CConfig::GetUpcEan, 199 IS9CConfig::SetUpcEan, 200 upcESelect IS9CConfig::GetUpcEan, 198 IS9CConfig::SetUpcEan, 200 Updating, bootloader, 77 700 Series Color Mobile Computer User’s Manual Index URLs ActiveSync, 29 Adobe Acrobat Reader, 116 AT command interface CDMA/1xRTT SB555, 116 GPRS/GSM GEM350X, 116 GPRS/GSM MC45, 116 customer support, xviii full screen display, 263 Knowledge Central, xviii MIBs, 125 Microsoft Exchange e-mail account, 53 Microsoft Passport account, 53 Microsoft support, 10 MSDN library, 260 Pocket PC, 10 Pocket PC support, 10 web support, xviii User Datagram Protocol. See UDP Using a message list, via Inbox, 43 UUID, 272 Video files, Windows Media Player, 57 Viewing mobile favorites and channels, Pocket Internet Explorer, 66 Virtual wedge bar code configuration grid, 371 postamble, 371 preamble, 371 configuration parameter, 325 code page, 329 grid, 328 postamble, 327 preamble, 326 data filtering, 141 filter expression values, 142 global amble IS9CConfig2::GetGlobalAmble, 211 IS9CConfig2::SetGlobalAmble, 212 operators, 144 Unit Manager, 350 VN_CLASS_ASIC, 266 VN_CLASS_BOOTSTRAP, 266 VN_CLASS_KBD, 266 Volume bar code configuration, 368 configuration parameter, 356 WAN radio CORE module, 111 WAN radio IDs ITC_DEVID_WANRADIO_NONE, 268 ITC_DEVID_WANRADIO_SIEMENS_MC45, 268 ITC_DEVID_WANRADIO_SIERRA_SB555, 268 WAN rado CORE module phone application, 115 700 Series Color Mobile Computer User’s Manual terminal application, 114 WAP pages, 62 connecting to an ISP, 68 Warm boot IOCTL_HAL_REBOOT, 278 IOCTL_HAL_WARMBOOT, 275 Web addresses. See URLs Web browsers, FTP support, 259 Web pages, 62 connecting to an ISP, 68 Web support, xviii Welch Allyn 1470 Imager cabling, 232 settings, 232 WEP encryption, 802.11 radio module, 91 Windows configuration, unit information control panel, WinCfg CAB file, 345 Windows Media files, Windows Media Player, 57 Windows Media Player, Pocket PC, 57 Wireless Application Protocol. See WAP pages Wireless network, 87 Wireless printing Bluetooth compatible module, 120 unit information control panel PDWPM0C CAB file, 345 WP_SAMPLE.CAB file, 345 Wireless TCP/IP installations, BlockSize parameter, 252 Wireless WAN AT command interface CDMA/1xRTT SB555, 116 GPRS/GSM GEM350X, 116 GPRS/GSM MC45, 116 CDMA/1xRTT, 110 GEM350x, 110 GSM/GPRS, 110 SB555, 110 testing AT commands, 117 wNumberOfMessages, IADC::QueryData, 155 Word documents. See Pocket Word Work creating a modem connection, 70 an Ethernet connection, 71 getting connected, 70 Writing mode, Pocket Word, 50 Writing on the screen See also Notes Pocket Word, 50 Writing to drivers DTR, 135 NPCP, 130 wStructSize, IBarCodeReaderControl::Read, 165 WWAN. See Wireless WAN Xscale processor ID, IOCTL_GET_CPU_ID, 280 397 Index Files Index Numbers 80211API.DLL, 100 80211CONF.EXE, 100 80211SCAN.EXE, 100 AUTOUSER.DAT, 79 CABWIZ.DDF, 249 CABWIZ.EXE, 236, 249 CEIMAGER.EXE, 80 CPL802.CPL, 100 DEVICEID.H, 272 EXITME.BIN, 259 FTPDCE.EXE, 256, 259 AutoFTP, 261 FTP Server, 251 FTPDCE.TXT, 259 IADC.H, IADC functions, 151 IADCDEVICE.H IADC::SetAttribute, 157 IBarCodeReaderControl::SetAttribute, 167 INTERMEC.MIB, 125 IS9CCONFIG.H IS9CConfig functions, 172 IS9CConfig2 functions, 204 ITCADC.MIB, 125 ITCDEVMGMT.H, 149 ITCDEVMGMT.LIB, 149 ITCSNMP.MIB, 125 ITCTERMINAL.MIB, 125 ITCUUID.LIB IADC functions, 151 IS9CConfig functions, 172 398 IS9CConfig2 functions, 204 MAKECAB.EXE, 249 MOD80211.DLL, 100 NETWLAN.DLL, 100 NPCPPORT.DLL, 129 NRINET.INI, 345 OEMIOCTL.H IOCTL_GET_CPU_ID, 280 IOCTL_HAL_COLDBOOT, 275 IOCTL_HAL_GET_BOOT_DEVICE, 277 IOCTL_HAL_GET_BOOTLOADER_VERINFO, 274 IOCTL_HAL_GET_OAL_VERINFO, 273 IOCTL_HAL_GET_RESET_INFO, 276 IOCTL_HAL_ITC_READ_PARM, 265 IOCTL_HAL_ITC_WRITE_SYSPARM, 270 IOCTL_HAL_REBOOT, 278 IOCTL_HAL_WARMBOOT, 275 ONEIL.DLL, 134 PKFUNCS.H IOCTL_HAL_GET_DEVICEID, 272 IOCTL_PROCESSOR_INFORMATION, 279 REBOOTME.BIN, 259 __RESETMEPLEASE__.T XT, 248 RPM.EXE, 241 RPMCE212.INI, 241 SETUP.DLL, 240, 248 DllMain, 248 SRDEVMGMT.CAB, 286 TAHOMA.TTF, 241 WCESTART.INI, 241 700 Series Color Mobile Computer User’s Manual Corporate Headquarters 6001 36th Avenue West Everett, Washington 98203 tel 425.348.2600 fax 425.355.9551 www.intermec.com 700 Series Color Mobile Computer User’s Manual - November 2002 *961054031* *961054031* REV B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2002:12:14 00:15:06Z Modify Date : 2003:02:04 11:39:57-08:00 Page Count : 134 Creation Date : 2002:12:14 00:15:06Z Mod Date : 2003:02:04 11:39:57-08:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : thinga Metadata Date : 2003:02:04 11:39:57-08:00 Creator : thinga Title : back_let85x11 Has XFA : No Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools