Intermec EasyCoder F4 – Installation & Operation Ed. 278 Chapter 11    MaintenancePrinthead Cleaning, cont'd.Wait for approx. 30 seconds to allow the cleaning fl uid to dissolve the residue. Insert most of the cleaning card under the printhead (1). Close the printhead (2).9Allow the cleaned parts to dry before loading any paper.Pull out the cleaning card. If necessary, repeat the process with a new cleaning card.8710
Intermec EasyCoder F4 – Installation & Operation Ed. 2   79 Chapter 11    Maintenance1External CleaningAlways remove the power cordbefore cleaning! Wipe external surfaces with a soft cloth slightly moistened with water or a mild detergent.3Never use any sharp tools for removing stuck labels. The printhead and rollers are delicate.Never spray the printer. Protect it from water when cleaning the premises.24
Intermec EasyCoder F4 – Installation & Operation Ed. 280 Chapter 11    MaintenanceCleaning the Paper GuidesBoth parts of the label stop sensor, which controls the paper feed, are covered by plastic guides. The guides are provided with seemingly non-transparent areas, through which the light between the two parts of the label stop sensor is transmitted. These areas (indicated by a shade of grey in illustration #2 below) must be kept clean from dust, stuck labels, and adhesive residue.If the printer starts to feeed our labels in an unexpected way. lift the upper guide – as described below – and check for anything that may block the beam of light (dust, stuck labels, adhesive residue etc.). If necessary, clean the guides using a cleaning card or a soft cloth soaked with isopropyl alcohol. Do not use any other the of chemical. Be careful not to scratch the guides.Caution!Isopropyl alcohol [(CH 3)2CHOH; CAS 67-63-0] is a highly fl ammable, moderately toxic and mildly irritating substance.  Lift the inner part of the upper guide and pull it outwards,disengaging it from the lower guide. Take care not to damage the cable.Tilt the upper guide upwards and clean the areas marked with grey. After cleaning, reas-semble in reverse order.1 2
Intermec EasyCoder F4 – Installation & Operation Ed. 2   81 Chapter 11    MaintenancePrinthead ReplacementThe printhead is subject to wear both from the direct thermal paper and from the rapid heating and cooling process during printing. Thus, the printhead will require periodical replacement.Time between printhead replacements depends on the print images, the type of paper in use, the amount of energy to the printhead, and several other factors.Note!While replacing the printhead, the power should be switched off.Open the side door. Turn the printhead lift knob clockwise to lift the printhead.1 2
Intermec EasyCoder F4 – Installation & Operation Ed. 282 Chapter 11    MaintenancePrinthead Replacement, cont'd.Pull the printhead bracket away from the magnet in the pressure arm.34 Disconnect the printhead bracket from the print mechanism – as indicated by the arrows –  and pull out the printhead as far as the cables allow.65Disconnect the cables from the printhead. Note the snap-lock on the inner connector. Pull at the connectors – not the cables!Remove the paper, if any.Snap-lock
Intermec EasyCoder F4 – Installation & Operation Ed. 2   83 Chapter 11    MaintenancePrinthead Replacement, cont'd.Connect the two cables to the replacement printhead. Put back the printhead in reserse order and check that the printhead cables run freely.9Load a new supply of paper as described ear-lier in this manual.Close the printhead so the magnet engages the printhead bracket.8710
Intermec EasyCoder F4 – Installation & Operation Ed. 284 Chapter 12Narrow Labels AdjustmentThe printer is factory-adjusted for full size paper width. When using paper less than full width, it is recommended to adjust the pressure arm so it becomes centred on the paper. Thereby, an even pressure across the paper is obtained. A poorly adjusted pressure arm may be detected by a weaker printout on the inner part of a less than full width paper. Similarly, when reverting to a wider paper, the arm should be adjusted, or the printout on the outer part of the paper could be weak.To adjust the pressure arm, proceed as follows:•   Loosen the nut that holds the pressure arm. Move the arm inwards or outwards until the arrow on the tip of the arm becomes centre-aligned with the paper web.      While moving the arm, push at the part where the nut is situated, not at the tip. If the arm is hard to move, lift the printhead and pull the printhead bracket free from the magnet in the arm. •   After having centred the arm, lock it by tightening the nut.     AdjustmentsCentre of PaperPressure ArmNut
Intermec EasyCoder F4 – Installation & Operation Ed. 2   85 Chapter 12    AdjustmentsLabel Stop SensorPositionThe label stop/black mark sensor (LSS) is a photoelectric sensor that controls the printer's paper feed by detecting gaps between labels, slots in paper strip, or black marks, depending on the printer's setup in regard of media type (see chapter 6 “Setting Up the Printer”). A prerequisite is obviously that the LSS is aligned with the slots or black marks.Thus, the LSS can be moved laterally between 5 fi xed positions. There is one sensor on top of the upper paper guide and underneath the bottom of the print unit. These two guides must be set individually to the same position. Push them inwards as far as they go and then pull them out – one at the time – while counting the clicks from the snap-locks.The various detection points of the sensor in relation to the inner edge of the paper are as follows:One click out                           3 mm              .118" Two clicks out                          8 mm               .315"Three clicks out                       12 mm             .472"Four clicks out                         16 mm             .639"Five clicks out                          20 mm            .787"If using irregularly shaped labels, align the LSS with the front tips of the labels Upper part of LSSPrint Unit(printhead and headlift shaft omitted for improved visibility)One Diode + One SensorLower part of LSSOne Sensor
Intermec EasyCoder F4 – Installation & Operation Ed. 286 Chapter 12   AdjustmentsPrinthead PressureThe pressure of the thermal printhead against the paper is factory adjusted. However, the use of thicker or thinner paper than normal could require the printhead pressure to be readjusted.Using a fl at-tipped screwdriver, turn the adjustment screw clockwise for increased pressure (+), or counter-clockwise for less pressure (-). Print a few labels, preferably test labels (see chapter 6 “Setting Up the Printer”), and check the printout. Increased pressure generally gives a darker printout and vice versa. Repeat until the desired result is obtained.To return to the factory setting, tighten the screw (+) as far as it goes and then loosen it (-) six (6) full turns.Note!Do not use a higher printhead pressure than necessary, because it may increase the wear of the printhead and thus shorten its life.Adjustment Screw
Intermec EasyCoder F4 – Installation & Operation Ed. 2   87 Appendix 1PrintingPrint Technique                                                                                  Direct ThermalPrinthead Resolution                                                                   8 dots/mm (203.2 dpi)                             Print Speed (variable)                                                       100 – 200 mm/sec. (≈ 4 – 8"/sec.)Print Width (max)                                                                              104 mm (4.095")                                   = 832 dotsPrint Length (max)                                                                     32767 dots  = 409.5 cm1                           Media Width (min/max)                                                            25 – 114.3 mm (1 –4.5")                            Standard paper guideMedia Width (min/max)                                                         40 – 114.3 mm (1.57 – 4.5")                         Quick-Load guidesPaper Roll Diameter (max)                                                               213 mm (8.38")                                   Short door/no rewindPaper Roll Core Diameter                                                 38 – 40 mm (1.5") or 76 mm (3")Print Directions                                                                                               4Modes of OperationTear Off                                                                                                         YesPeel Off                                                                                                     Optional                                         Requires Rewind UnitFirmwareOperating System                                                                    Intermec Fingerprint 7.31                           Incl. Direct ProtocolSmooth Fonts                                                                        TrueDoc and TrueType fontsBuilt-in scalable fonts (std)                                                                           15                                               Unicode fonts2Built-in bar code symbologies (std)                                                            36Startup Program (std)                                                                    Intermec Shell 4.4Physical MeasuresDimensions (W x L x H)                                             244 x 397 x 178 mm (9.61 x 15.63 x 7.00")            w. Long side doorWeight (excluding media)                                                               ≈ 7 kgs (15.5 lbs)                                  Depending on modelAmbient Operating Temperature                                     +5°C – +40° C (+41°F – +104° F)Humidity                                                                                    20 –80% non-condensingElectronicsMicroprocessor                                                                                     32 bit RISCOn-board Flash SIMMs                                                                             1 – 2                                            Std. 1 x 2 MbytesOn-board DRAM SIMM                                                                                1                                                Std. 4 MbytesReal-Time Clock                                                                                       Option                                           10+ years lifePower SupplyMains Voltage                                                                       >90 – <264 V AC, 45 – 65 Hz                       PFC Regulation                                                                                 IEC 61000-3-2Maximum Power Consumption                                        Continuous 140 W; Peek 300WTechnical Data
Appendix 1  Technical Data88 Intermec EasyCoder F4 – Installation & Operation Ed.2Technical Data, cont’d.SensorsLabel Gap/Black Mark/Out of Paper Yes 5 fixed positionsPrinthead Lifted YesControlsControl Lamps 3Display 2 x 16 character LCD w. background lightKeyboard 22 keys membrane switch typePrint Button 1Beeper YesData InterfacesSerial 1 x RS 232C + 1 x USBBar Code Wand YesElectronic Keys 2 For setupConnection for Optional Interface Boards 1 Future optionMemory Card Adapter 1Accessories and Options Flash or SRAM cardsRFID Module OptionRewind Unit Option For peel-off operationPaper Supply Spool Option Replaces hanger3” Adapter for Paper Supply Spool OptionShort Side Door Option3Long Side Door Option3Label Taken Sensor OptionReal-Time Clock Option 10+ years lifeQuick-Load Guides Standard Fitted in some modelsRS 232C Cable OptionEasySet Bar Code Wand Option For quick setupParallel Interface Board Option IEEE 1284Double Serial Interface Board OptionIndustrial Interface Board OptionEasyLAN 100I Interface Board Option EthernetExternal Alphanumeric Keyboard OptionFlash Memory Cards Option = 64 Mbit (8 MB)Electronic Keys Option1. The max. print length is also restricted by the amount of free DRAM memory.2. Latin, Greek, and Cyrillic fonts according to Unicode standard are included.3. Depending on model, the printer may be delivered with either a long or a short side door.
Intermec EasyCoder F4 – Installation & Operation Ed. 2   89 Appendix 2Media Specifi cationsDirect Thermal LabelsIntermec offers two quality grades of direct thermal paper for the EasyCoder range of printers:•   Premium Quality: Top-coated papers with high demands on printout quality and resistance against moisture, plasticisers and vegetable oils. Examples...     - Top Board    - Duratherm II,      - Premium    - Duratherm II Tag           - Duratherm Ltg.           - Duratherm IR•   Economy Quality: Non top-coated papers with less resistance to moisture, plasticisers and vegetable oils. In all other respects, it is equal to Premium Quality. Examples...     - Economy     - Eco Board
Intermec EasyCoder F4 – Installation & Operation Ed. 290 Appendix 2  Media Specifi cationsPaper Roll SizeCoreDiameters: 38 – 40 mm (1.5")  or 76.2 mm (3") Width:    Must not protrude outside the web.The web must be wound up on the core in such a way that the printer can pull the end of the web free.RollMax. diameter (internal supply only):            - Position 1                                          152 mm      (6.00")- Position 2                                           213 mm      (8.38")- Position 3                                          203 mm      (8.00")Max. width:                                      114.3 mm      (4.50")Min. width (standard):                         25 mm      (1.00")Min. width (Quick-Load):                   40 mm      (1.57")Max. web thickness:                            175 µm      (0.007")The maximum recommended web thickness is 175µm. A thicker web may be used, but print quality will be reduced. Web stiffness is also important and must be balanced against web thickness to maintain print quality.Paper rolls fitted inside the printer should be wound with the printable side facing outwards.The paper supply must not be exposed to dust, sand, grit, etc. Any hard particles, however small, can damage the printhead.
Intermec EasyCoder F4 – Installation & Operation Ed. 2   91 Appendix 2    Media Specifi cationsNon-Adhesive StripPaper⇐ a ⇒  Web Width:Maximum: 114.3 mm (4.50")Minimum (standard):  25.0 mm  (1.00")Minimum (Quick-Load):  40.0 mm  (1.57")Media Type Setup:• Fix length strip• Var length strip
Intermec EasyCoder F4 – Installation & Operation Ed. 292 Appendix 2  Media Specifi cations⇐ a ⇒  Web Width (including backing paper):Maximum: 114.3 mm (4.50")Minimum (standard):  25.0 mm  (1.00")Minimum (Quick-Load):  40.0 mm  (1.57")⇐ b ⇒   Backing PaperThe backing paper must not extend more than a total of 1.6 mm (0.06") outside the paper and should protrude equally on both sides.⇐ c ⇒   Paper Width (excluding backing paper):Maximum: 112.74 mm (4.43")Minimum: 23.8 mm (0.94")Media Type Setup:• Fix length strip• Var length stripSelf-Adhesive StripPaper, cont'd.
Intermec EasyCoder F4 – Installation & Operation Ed. 2   93 Appendix 2    Media Specifi cations⇐ a ⇒   Web Width (including backing paper):Maximum: 114.3 mm (4.50")Minimum (standard):  25.0 mm  (1.00")Minimum (Quick-Load):  40.0 mm  (1.57")⇐ b ⇒   Backing PaperThe backing paper must not extend more than a total of 1.6 mm (0.06") outside the paper and should protrude equally on both side. Recommended min. transparency: 40% (DIN 53147).⇐ c ⇒   Label Width (excluding backing paper):Maximum: 112.7 mm (4.43")Minimum: 23.8 mm (0.94")⇐ d ⇒   Label Length:Minimum: 8.0 mm (0.32")Max label length:  depends on DRAM  sizeUnder favourable circumstances, a minimum label length down to 4 mm (0.16") could be used. It requires the sum of the label length (d) and the label gap (e) to be larger than 7 mm (0.28"), that batch printing is used, and that no pull back of the paper is performed. Intermec does not guarantee that such short labels will work, but it is up to the user to test this in his unique application. ⇐ e ⇒   Label Gap:Maximum: 21.3 mm (0.83")Recommended: 3.0 mm (0.12")Minimum: 1.2 mm (0.05")The Label Stop Sensor must be able to detect the extreme front edges of the labels. It can be moved between 5 fi xed positions at the following distances from the inner edge of the paper.  3 mm            (.118")  8 mm            (.315")12 mm            (.472")16 mm             (.639")20 mm             (.787")Media Type Setup:• Label (w gaps)Self-Adhesive LabelsPaper, cont'd.
Intermec EasyCoder F4 – Installation & Operation Ed. 294 Appendix 2  Media Specifi cationsPaper, cont'd.Tickets with Gap⇐ a ⇒   Web Width:Maximum: 114.3 mm (4.50")Minimum (standard):  25.0 mm  (1.00")Minimum (Quick-Load):  40.0 mm  (1.57")⇐ b ⇒  Copy Length:Min. length between slots:  8.0 mm  (0.32") Max. length between slots:                 depends on DRAM sizeUnder favourable circumstances, a minimum ticket length down to 4 mm (0.16") could be used. It requires the sum of the copy length (b) and the detection slit height (e) to be larger than 7 mm (0.28"), that batch printing is used, and that no pull back of the paper is performed. Intermec does not guarantee that such short labels will work, but it is up to the user to test this in his unique application. ⇐ c ⇒   LSS Detection Position:Five fi xed positions (distance from inner edge of paper):  3 mm            (.118")  8 mm            (.315")12 mm            (.472")16 mm             (.639")20 mm             (.787")⇐ d ⇒   Detection Slit Length:The length of the detection slit (excluding corner radii) must be minimum 2.5 mm (0.10") on either side of the LSS detection position (e).⇐ e ⇒   Detection Slit Height:Maximum: 21.3 mm (0.83")Recommended: 1.6 mm (0.06")Minimum: 1.2 mm (0.05")Media Type Setup:• Ticket (w gaps)Do not allow any perforation to break the edge of the web, as this may cause the web to split, resulting in a paper jam.
Intermec EasyCoder F4 – Installation & Operation Ed. 2   95 Appendix 2    Media Specifi cationsPaper, cont'd.Tickets with Black Mark⇐ a ⇒   Web Width:Maximum: 114.3 mm (4.50")Minimum (standard):  25.0 mm  (1.00")Minimum (Quick-Load):  40.0 mm  (1.57")⇐ b ⇒   Copy Length:Minimum: 20.0 mm (0.8")Maximum:  depends on DRAM size⇐ c ⇒   LSS Detection Position:Five fi xed positions (distance from inner edge of paper):  3 mm            (.118")  8 mm            (.315")12 mm            (.472")16 mm             (.639")20 mm             (.787")⇐ d ⇒   Black Mark Width:The detectable width of the black mark should preferably be at least 5.0 mm (0.2") on either side of the LSS detection point.  ⇐ e ⇒   Black Mark Length:Maximum: 21.3 mm (0.83")Common: 12.5 mm (0.5")Minimum: 5.0 mm (0.2")⇐ f ⇒   Black Mark Y-Position:It is recommended to place the black mark as close to the front edge of the ticket as possible and use a negative Stop Adjust value to control the paper feed, so the tickets can be properly torn or cut off.Media Type Setup:• Ticket (w mark) Important! Preprint that may interfere with the detection of the black mark should be avoided on the back of the paper. However, the LBLCOND statement allows the sensor to be temporarily disabled during a specifi ed amount of paper feed in order to avoid unintentional detection, see Intermec Fingerprint manuals.The black mark should be non-refl ective carbon black on a whitish background.Do not allow any perforations to break the edge of the web, as this may cause the web to split, resulting in a paper jam.
Intermec EasyCoder F4 – Installation & Operation Ed. 296 Appendix 3InterfacesRS 232C Interface"uart1:"The EasyCoder F4 has – as standard – two serial communication interfaces: RS 232C on "uart1:" and USB (see next page).ProtocolDefault setup: Baudrate: 9600Char. length  8 bitsParity:   NoneStop bits:   1 RTS/CTS DisabledENQ/ACK: DisabledXON/XOFF:  Disabled (both ways)New Line:  CR/LFTo change the serial interface settings, see chapter 6 “Setting Up the Printer”.Interface CableComputer end:  DB-9 or DB-25 female connector (PC) Printer end:   DB-25 male connector Host  EasyCoder F4   HostSignal DB-9 DB-25 Signal  DB-25 DB-25 Signal  1 1    1 1 shieldRXD 2 2 TXD  2 3 RXDTXD 3 3 RXD  3 2 TXDCTS  8 4  RTS  4 5 CTSRTS  7 5  CTS  5 4 RTS  6 DSR 6 20 DTRGND 5 7 Signal GND 7 7 GND  16 + 5V1 16DSR  6 20  DTR  20 6  DSR  22 RI 221/. The external +5V is limited to 200 mA and is automatically turned off at overload. It is intended to drive e.g. an external alphanumeric keyboard connected to the RS 232C port.
Intermec EasyCoder F4 – Installation & Operation Ed. 2   97 Appendix 3    InterfacesUSB InterfaceThe EasyCoder F4 has – as standard – one USB communication port. To use the USB interface for printing from a PC, you need a special USB printer driver installed in your PC.Using an USB Class A - B cable, connect the Class A end to your PC or hub and the Class B end to your EasyCoder F4 printer. USB = Universal Serial BusUSB Class A connector.Connect to PC or hub.USB Class B connector.Connect to USB receptacle on the printer's rear plate.Note:The USB interface is presently not supported by the Intermec Fingerprint fi rmware (v. 7.31).USB
Intermec EasyCoder F4 – Installation & Operation Ed. 298 Appendix 3  InterfacesThe EasyCoder F4 can optionally be fi tted with an extra double serial interface board, which provides the printer with two more serial ports; "uart2:" and "uart3:". These ports can be confi gured for various types of serial communication in combination according to the customer's request. Use the Intermec Fingerprint instruction SETSTDIO to select standard IN and OUT ports (by default "uart1:" is both std IN and OUT port)1."uart2:"  "uart3:"RS 232C   RS 232CRS 422 Non-isolated  RS 422 Non-isolatedRS 422 Isolated    20 mA Current LoopRS 485 "uart2:" Serial PortThe communication ports "uart2:" uses a female DB 25 connector. Pin Signal Name Description 1    Not connected  2  TxD  RS 232 Transmitter  3  RxD  RS 232 Receiver  4  RTS  RS 232 Request To Send  5  CTS  RS 232 Clear To Send  6  DSR  RS 232 Data Set Ready 7  GND  Ground 8–14   Not connected  15  +RS422I  +RS 422 Receive  16  +5V  5 Volt for external use (max. 200 mA)1  17  -RS422I  -RS 422 Receive 18    Not connected  19  +RS422O/+RS485  +RS 422 Transmit/+RS 485  20  DTR  RS 232 Data Terminal Ready  21  -RS422O/-RS485  -RS 422 Transmit/-RS 485  22  RI  RS 232 Ring Indicator  23  Shield  Optional shield for RS 422 and RS 485 24–25   Not connected1/. The external 5V is automatically turned off at overload. Double Serial Interface Board"uart2:"1/. Intermec Shell either auto-matically sets the correct std IN and OUT port when an applica-tion is selected, e.g. a Windows driver, or prompts you to select one, see chapter 8.
Intermec EasyCoder F4 – Installation & Operation Ed. 2   99 Appendix 3    Interfaces"uart3:" Serial PortThe communication ports "uart3:" uses a male DB 25 connector. Pin  Signal Name  Description 1    Not connected  2  TxD  RS 232 Transmitter  3  RxD  RS 232 Receiver  4  RTS  RS 232 Request To Send  5  CTS  RS 232 Clear To Send  6  DSR  RS 232 Data Set Ready 7  GND  Ground 8    Not connected  9  +20M1  +20 mA current loop  10  -20M1  -20 mA current loop   11  +TXD  +TXD 20 mA current loop   12  -TXD  -TXD 20 mA current loop  13  +20M2  +20 mA current loop       (printer active receiver)  14  -20M2  -20 mA current loop        (printer active receiver)  15  +RS422I  +RS 422 Receive  16  +5V  5 Volt for external use (max. 200 mA)1  17  -RS422I  -RS 422 Receive  18  +RxD  +TXD 20 mA current loop  19  +RS422O/+RS485  +RS 422 Transmit/+RS 485  20  DTR  RS 232 Data Terminal Ready  21  -RS422O/-RS485  -RS 422 Transmit/-RS 485  22  RI  RS 232 Ring Indicator  23  Shield  Optional shield for RS 422 and RS 485 24    Not connected  25  -RxD  -TXD 20 mA current loop1/. The external 5V is automatically turned off at overload.Double Serial Interface Board, cont'd."uart3:"
Intermec EasyCoder F4 – Installation & Operation Ed. 2100 Appendix 3  Interfaces1/. Nibble, byte, ECP and EPP from printer to host are presently not supported.2/. Intermec Shell either auto-matically sets the correct std IN and OUT port when an applica-tion is selected, e.g. a Windows driver, or prompts you to select one, see chapter 8.IEEE 1284Parallel Interface BoardThe EasyCoder F4 can optionally be fi tted with an IEEE 1284-I compatible parallel interface board1. The parallel port is addressed in Intermec Fingerprint as device "centronics:". Select "centronics:" as standard IN port by means of the instruction SETSTDIO (by default, "uart1:" in std IN port)2.Interface Cable ConnectorsComputer end:  Depends on type of host computer.Printer end:  36 pin female IEEE 1284B Centron Pin Signal Name 1  DStrobe 2–9 Data 0–7 10  Ack 11  Busy 12  PE 13  Select 14  AF 15  Not connected 16  Ground 17  Screen 18  +5V Ext 19 –30 GND 31  Init 32  Error 33-35  Not connected 36  Selectin"centronics:"
Intermec EasyCoder F4 – Installation & Operation Ed. 2   101 Appendix 3    InterfacesIndustrial Interface BoardThe EasyCoder F4 can optionally be fitted with an Industrial Interface Board, that provides the printer with one extra serial communication port ("uart2:"), which can be confi gured for one of the following alternativesRS 232C    RS 422 Non-isolated   RS 422 Isolated   RS 485This port is identical to "uart2:" on the double serial interface board.The Industrial Interface Board also has a female DB-44 connector with...8 digital IN ports with optocouplers8 digital OUT ports with optocouplers4 OUT ports with relays.Refer to the installation instructions for the Industrial Interface Board for further information."uart2:"Industrial Interface
Intermec EasyCoder F4 – Installation & Operation Ed. 2102 Appendix 3  InterfacesThe Intermec EasyLAN 100i Ethernet interface board provides the printer with a 10BaseT Ethernet or 100BaseTX Fast Ethernet network connection. You can communicate with the printer via a LAN (Local Area Network) or provide the printer with its own home page, so you can reach the printer via internet on the world wide web (www).EasyLAN 100i supports most major computer systems and environ-ments. You can assign passwords to restrict both login and printer access. The internal EasyLAN 100i web pages allow you to con-tinuously monitor printer status and to upgrade the fl ash memory of the printer when new fi rmware becomes available.EasyLAN 100i supports SNMP for remote monitoring.When an EasyLAN 100i interface board is fi tted in the printer, some extra menus will be added to the Setup Mode (see chapter 7 “Setup Mode”). The Ethernet port is addressed in Intermec Fingerprint 7.3 or later as device "net1:" (communication channel 5). EasyLAN 100i Interface BoardRJ-45connector
Intermec EasyCoder F4 – Installation & Operation Ed. 2   103 Appendix 4EasySet Bar Code Wand Setup1.  Connect the optional EasySet bar code wand to the receptacle on the printer’s rear plate.3.  When the bar code has been accepted, the printer emits a short beep and the Ready control lamp on the printer’s front blinks briefl y.2.  Read the appropriate bar code to set up the printer. Hold the wand like a pencil and move it rather swiftly across the bar code. 4.  This manual only contains a selection of setup options. For information on how to produce your own setup bar codes, please refer to the Intermec Fingerprint 7.31 Reference Manual. Connecthere!Connection and Operation
Intermec EasyCoder F4 – Installation & Operation Ed. 2104 Appendix 4     EasySet Bar Code Wand SetupSerial Communication on "uart1:"BaudrateParityChar. Length
Intermec EasyCoder F4 – Installation & Operation Ed. 2   105 Appendix 4    EasySet Bar Code Wand SetupSerial Communication on "uart1:", cont'd.No. of Stop BitsRTS/CTSXON/XOFF, Data to HostReset comm. to defaultENQ/ACK
Intermec EasyCoder F4 – Installation & Operation Ed. 2106 Appendix 4     EasySet Bar Code Wand SetupStart- and StopadjustPeel OffTear OffXON/XOFF, Data from HostNew LineSerial Communication on ”uart1:”, cont’d.Default
Intermec EasyCoder F4 – Installation & Operation Ed. 2   107 Appendix 4    EasySet Bar Code Wand SetupContrast
Intermec EasyCoder F4 – Installation & Operation Ed. 2108 Appendix 4     EasySet Bar Code Wand SetupMedia WidthTest Labels
Intermec EasyCoder F4 – Installation & Operation Ed. 2   109 Appendix 4    EasySet Bar Code Wand SetupMedia Length
Intermec EasyCoder F4 – Installation & Operation Ed. 2110 Appendix 4     EasySet Bar Code Wand SetupPrint SpeedMedia Type
Intermec EasyCoder F4 – Installation & Operation Ed. 2   111 Appendix 4    EasySet Bar Code Wand SetupDirect Thermal Printing (Europe)Paper TypeDirect Thermal Printing (USA)
Intermec EasyCoder F4 – Installation & Operation Ed. 2Appendix 5  RFID ModuleRFID ModuleThe EasyCoder F4 can optionally be fitted with an Intellitag® 500 RFID (radio frequency identification) board that provides the printer with the means to pre-program Intellitag® 500 RFID SmartLabels when the bar code portion of the label is printed.The RFID board is addressed in Intermec Fingerprint 7.3 or later as device “uart2:”The RFID board does not require connection to any device external to the printer.The RFID module is fitted in the printer in the space allocated for optional interface boards and therefore cannot be used in conjuction with, or in addition to, any of the optional interface boards.Refer to the installation instructions for the RFID Option Board for further information.Chassis location for RFID module112