Intermec Technologies IM5R3 IM5r3 User Manual IM5 Module QSG
Intermec Technologies Corporation IM5r3 IM5 Module QSG
Contents
- 1. Compliance Insert
- 2. Quick Start Guide
Quick Start Guide
Installation and Quick Start Guide IM5 Reader Module Packing List Check to ensure that you receive these items: S IntermecR IM5 Reader Module S Compliance Statement S Warranty Card Host Communication Host communication comes through the 9-pin female D-sub connector. RS-232 standards are supported as ordered from the factory or service center. S The maximum data rate is 115.2K baud, with 8 data bits, no parity bit, and 1 stop bit. S The maximum RS-232 distance from the reader to the host, modem, or other physical controller interface is 50 feet (15.2 meters). RS-232 Connections Pin Number Definition TXD (Transmit Data) to the host RXD (Receive Data) from the host Ground CTS (Clear to Send) from the host RTS (Request to Send) to the host Power Requirements Power comes in from 8 to 10 volts DC. Your 915 MHz Reader uses less than 2.4 amps. Intermec supplies 9 volts DC at 2.4 amps from Intermec power supply, p/n: 851-067-001. IM5 Reader Module Installation and Quick Start Guide User I/O A general purpose I/O (Input/Output) connector provides signal lines in and out of the reader allowing monitoring and/or control of external devices or functions. The connector for this is a 13-pin female circular DIN. The mating male connector you need for mating with this is an Intermec p/n: 351-184-001. I/O Pin-outs Pin Number Definition GPIO IN0 GPIO IN1 GPIO IN2 GPIO IN3 GPIO OUT0 GPIO OUT1 GPIO OUT2 GPIO OUT3 9 through 13 Ground through individual 10 ohm resistors Outputs and inputs have 12 volt transient suppression devices to ground at the connector. Output signals are driven by 2N3904 NPN transistors (low level) with a 100 kohm pull-up to +5 volts through a silicon diode, giving about a 4.3 volt high level. An output can be pulled high from an external source as high as 12 volts. This will however tend to pull the other outputs higher (through two 100k resistors). The low level will be about 0.1 volt up to about 30 mA. The output low voltage will climb higher as the sink current increases. There is no protection on this. You need to ensure that their load won’t require the reader to sink more than 50 mA. Input signals should be 0 to +1.5 volt for a low input and +3.5 to +5 volts for a high input. Each input has a 1.1 kohm resistor in series with clamping diodes, but only about 1 µA is used until the input exceeds the 0 to +5 volt input range. There is also a weak (100 kohm) pull-up to +5 volt on each input. IM5 Reader Module Installat ion and Quick Start Guide Installing the IM5 Reader Module The IM5 Reader Module requires 8-10 volts DC at 2 amps. The IF4 Serial Reader is powered through a 2-pin bulkhead barrel connector (Switchcraft p/n: 712A). The Reader Module supplies 9-volt 2.4 amps to this connector. Mating plugs for this connector are Switchcraft part numbers 760, 760K or 761K. A cable within the PSR connects the bulkhead barrel connector, via an endplate switch, to the 2-pin Molex connector on the IM5 Reader Module. IM5 Reader module Auxiliary I/O Connector Cable connector RS-232 port The IM5 Reader Module has holes along the sides that can be used for mounting. For best results, attach heat sink to case via the screwholes in the heat sink. IM5 Reader module Screw holes IM5 Reader Module Installation and Quick Start Guide Connecting and Getting Started FCC and Industry Canada regulations limit exposure to radiofrequency (RF) radiation. To comply with these regulations, operators of this device must maintain a distance of at least 23 cm. (9.1 inches) from the cover on the antenna assembly (The cover on the antenna is the dome shaped surface). While the device is on, the operator’s body and parts of the body such as eyes, hands, or head, must be 23 cm. (9.1 inches) or farther from the cover of the antenna assembly. FCC and Industry Canada regulations also require that the antenna assembly of this device be installed in accordance with the installation procedures to allow the operator to comply with the limit. Use of antennas and accessories not authorized may void the compliance of this product and may result in RF exposures beyond the limits established for this equipment. IM5 Reader Module Installat ion and Quick Start Guide Antenna Installation 1 Connect the antenna cable to a port. The four antenna connectors have lock washers and nuts to allow for panel mounting. 2 Connect a reverse SMA terminator (Intermec p/n 345-004-001) to any port that does not have an antenna attached. Each port must have either an antenna or a terminator connected. Do not apply power to the Reader unless an antenna cable or terminator is installed on each antenna port. Antenna ports (4) Washers (4) Nuts (4) Reverse SMA terminator Reverse SMA Antenna cable Reader LED Explanation LED Meaning Power On Reader communicating with host, LED flashes as data transfer occurs. Reader searching for tags Reader communicating with a tag, LED flashes as transfer occurs. IM5 Reader Module Installation and Quick Start Guide Troubleshooting Troubleshooting Doesn’t Recognize Tag 1. Ensure antenna is properly connected. 2. Ensure reader is connected to your computer. 3. Ensure computer is plugged into AC outlet and computer is On. 4. Ensure tag is within range of antenna. 5. Call Intermec Technical Support 1-800-755-5505 (option 2). Product Specifications Dependent upon operating conditions and demands expected. If used in a normal office environment with good read conditions, you could expect to read up to 60 tags per second. Tags located too far away or in poor locations, with respect to interfering objects, provides poor results. Firmware Architecture Firmware Spec Detail Protocol/Compatibility Communicates in three modes: Application Peripheral Interface (API) and Basic Reader Interface (BRI).ANSI CCITS 256.2000 for API, part 2, part 3-1 General Specifications Receiver Spec Detail Protocol ISO 180006B Tag data rates 32 kbps Transmitter Spec Detail Protocol Intellitag Transmitter type On/Off Keying Frequency stability <± 100 ppm from -25° to +55°C RF Antenna Connections Spec Detail Number of antennas up to 4, electronically switched Antenna port isolation ≥22 dB IM5 Reader Module Installat ion and Quick Start Guide General Specifications (continued) Physical Specifications Spec Detail Size 8.25 in. x 5.30 in. x 2.9 in. Weight 38.4 oz. (1.1 kg) Frequency reference Source Spec Detail Frequency of operation 902-928 MHz Usable channels 51 Transmitter Spec Detail Output power 1.00 Watt maximum Occupied frequency bandwidth <250 KHz Environmental Specifications Temperature Spec Detail Operating -4°F to +131°F (-20°C to +55°C) Storage -31°F to +158°F (-35°C to +70°C) Humidity Spec Detail Operating 95% Relative Overall Performance Dispatch Rates Spec Detail RFID tag identification rate 60 tags per second RFID tag data exchange rates Read a tag containing 8 bytes of data within 12 mS. Perform a verified write to a tag at an average rate of 31 mS per byte per tag. Write Range Spec Detail Write range Distances up to 70% of the read distance under the same conditions. IM5 Reader Module Installation and Quick Start Guide Reliability Safety and Regulatory Approvals Spec Detail Reader module UL 60950-1-UL Recognized Component. Electromagnetic Compatibility Spec Detail Reader Module EN55022 (CISPR 22) Class B digital emissions EN55024 Immunity EN61000-3-2, -3 AC Power Harmonic Emissions and Flicker Radio Frequency Device Approval Spec Detail Reader Module FCC Part 15.247 Industry Canada RSS 210 Global Services and Support Warranty Information To understand the warranty for your Intermec product, visit the Intermec web site at http://www.intermec.com and click Service & Support. The Intermec Global Sales & Service page appears. From the Service & Support menu, move your pointer over Support, and then click Warranty. Web Support Visit the Intermec web site at http://www.intermec.com to download our current manuals in PDF format. To order printed versions of the Intermec manuals, contact your local Intermec representative or distributor. Visit the Intermec technical knowledge base (Knowledge Central) at http://intermec.custhelp.com to review technical information or to request technical support for your Intermec product. IM5 Reader Module Installat ion and Quick Start Guide Telephone Support These services are available from Intermec Technologies Corporation. In the U.S.A. and Canada call 1-800-755-5505 and choose this option Service Description Factory Repair and On-site Repair Request a return authorization number for authorized service center repair, or request an on-site repair technician. Technical Support Get technical support on your Intermec product. Service Contract Status Inquire about an existing contract, renew a contract, or ask invoicing questions. Schedule Site Surveys or Installations Schedule a site survey, or request a product or system installation. Ordering Products Talk to sales administration, place an order, or check the status of your order. Outside the U.S.A. and Canada, contact your local Intermec representative. To search for your local representative, from the Intermec web site, click Contact. 10 IM5 Reader Module Installation and Quick Start Guide IM5 Reader Module Installat ion and Quick Start Guide 11 Corporate Headquarters 6001 36th Avenue West Everett, Washington 98203 U.S.A. tel 425.348.2600 fax 425.355.9551 www.intermec.com e 2004 by Intermec Technologies Corporation. All rights reserved. IM5 Reader Module Installation and Quick Start Guide *962 054 121A* P/N: 962-054-121A 12 IM5 Reader Module Installation and Quick Start Guide
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 12 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:b472b627-85cd-4895-8596-957d87059166 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2004:11:30 07:44:54-06:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2004:12:01 12:04:49-08:00 Metadata Date : 2004:12:01 12:04:49-08:00 Document ID : uuid:1ca53897-6098-4420-a2b5-ba6d748e1833 Format : application/pdf Title : IM5 Module QSG Creator : SmithLes Author : SmithLesEXIF Metadata provided by EXIF.tools