Intermec Technologies ITRM24501 Intellitag RFID Radio User Manual 24501 Rdr QkSt

Intermec Technologies Corporation Intellitag RFID Radio 24501 Rdr QkSt

Contents

Intermec Quick Start Guide

164. "#
4A=@AH
Quick Start Guide
PRELIMINARY
EDITION 28--MAR--02
ITRF24501 Reader Quick Start Guide
2
Packing List
WARNING: This is a Class A product. In a domestic
environment this product may cause radio
interference in which case the user may be
required to take adequate measures.
Check to ensure that you receive these items:
IntermecR
RR
R2450 Fixed Reader
Model Number: ITRF24501
(part number country dependent)
Product Warranty Card
Compliance Statement
RF ID 2450 MHz Dipoles on FR4 Sample Tags
p/n ITTF2451001
ITRF24501 Reader Quick Start Guide
3
Host Communication
Host communication comes through the 9-pin female D-sub
connector. Both RS-232 and RS-422 standards are supported as
ordered from the factory or service center.
Table 1-1
RS-232 Connections
Pin Number Definition
2 Serial Data from the Fixed Reader to the host
3 Serial Data to the Fixed Reader from the host
5 Ground
7 CTS (Clear to Send) to the Fixed Reader from the
host
8 RTS (Request to Send) from the Fixed Reader to the
host
Table 1-2
RS-422 Connections
Pin Number Definition
1 Serial Data Out + from the Fixed Reader to the host
4 Serial Data Out -- from the Fixed Reader to the host
5 Ground
6 Serial Data In + to the Fixed Reader from the host
9 Serial Data In -- to the Fixed Reader from the host
The default baud rate is 115.2 kbps with 8 data bits, no parity
and 1 stop bit.
ITRF24501 Reader Quick Start Guide
4
Power Requirements
Power comes in from 8 to 10 volts DC. The Fixed Reader uses
less than 2 amps. Intermec supplies 9 volts DC at 2.4 amps
from Intermec power supply, #351-066-001.
User I/O
A general purpose I/O (Input/Output) connector provides signal
lines in and out of the reader allowing monitoring and/or con-
trol of external devices or functions.
The connector for this is a 13-pin female circular DIN. The
mating male connector you need for mating with this is a CUI
# SD-130, (one source is Digi-Key #CP-1013-ND).
Table 1-3
I/O Pin-outs
Pin Number Definition
1GPIOIN0
2GPIOIN1
3GPIOIN2
4GPIOIN3
5GPIOOUT0
6GPIOOUT1
7GPIOOUT2
8GPIOOUT3
9, 10, 11, 12, 13 GROUND though individual 10 ohm resistors
Outputs and inputs have 12 volt transient suppression devices
to ground at the connector. Output signals are driven by
2N3904 NPN transistors (low level) with a 100 kohm pull--up
to +5 volts through a silicon diode, giving about a 4.3 volt high
level. An output can be pulled high from an external source as
high as 40 volts. This will however tend to pull the other out-
puts higher (through two 100k resistors). The low level will be
about 0.1 volt up to about 30 mA. The output low voltage will
ITRF24501 Reader Quick Start Guide
5
climb higher as the sink current increases. There is no protec-
tion on this. You need to ensure that their load won’t require
thereadertosinkmorethan50mA.
Input signals should be 0 to +1.5 volt for a low input and +3.5
to +5 volts for a high input. Each input has a 1.1 kohm resistor
in series with clamping diodes, but only about 1PA is used until
the input exceeds the 0 to +5 volt input range. There is also a
weak (100 kohm) pull--up to +5 volt on each input.
ITRF24501 Reader Quick Start Guide
6
Connecting and Getting Started
WARNING: FCC regulations limit exposure to
radiofrequency (RF) radiation. To comply with
these regulations, operators of this device must
maintain a distance of at least 20 cm. (8 inches)
from the cover on the antenna assembly (The
cover on the antenna is the dome shaped
surface). While the device is on, the operator’s
body and parts of the body such as eyes, hands,
or head, must be 20 cm. (8 inches) or farther
from the cover of the antenna assembly.
FCC regulations also require that the antenna
assembly of this device be installed in
accordance with the installation procedures to
allow the operator to comply with the limit.
ITRF24501 Reader Quick Start Guide
7
Antenna Installation
Ensure that you read the above warning before installing the
antennas and using your Reader product.
Back view Front view
Reader to antenna cable
Mounting bracket
1. Review the locations where the Reader products need in-
tegrated. Ensure that you have careful considered the
safe distances for product placement for workers and any
other personnel that may get in the RF path.
2. Place the radio and antennas with cabling are easily ac-
cessible for installation and troubleshooting.
3. Use the mounting bracket to attach the antenna to a
fixed surface.
4. Attach the antenna to one of the four antenna ports on
the back of the Reader.
ITRF24501 Reader Quick Start Guide
8
The following illustration is an example of a typical Reader
installation.
EXAMPLE: Two Product Line Conveyers, showing two antennas
on each line. Two antennas in a crossing pattern
provide angular diversity to improve read capability
when tag orientation is unknown.
The frames for these stations are PVC tubing with RF reflec-
tive Mylar liner X2. Ensure that an eight inch (20 cm) distance
from the antenna assembly is maintained to limit people’s ex-
posure to radiofrequency (RF) radiation.
WARNING: While the device is on, the operator’s body and
parts of the body such as eyes, hands, or head,
must be 20 cm. (8 inches) or farther from the
cover of the antenna assembly.
Conveyer Belt #1
Conveyer Belt #2
33” Max.
distance
to tag
A singular antenna in a portal may be sufficient
in applications where there is a known tag orientation
ITRF24501 Reader Quick Start Guide
9
Connecting the Antenna to the Reader
1. Connect the antenna cable to a port.
2. Connect an SMA reverse--sex SMA terminator (Intermec
p/n 345-004-001) to any port that does not have an anten-
na attached.
"NOTE: Each port must have either an antenna or a termina-
tor connected.
1234
Antenna ports
Back panel Antenna cable
SMA terminator
3. Connect the Reader to a power source using power supply
p/n 351-066-001 and country dependent AC power cord.
4. Turn on your reader.
Power supply
Power cord
ITRF24501 Reader Quick Start Guide
10
5. Review the front panel LEDs to become familiar with the
status indications you will receive from your Reader.
RS-232 or
RS-422 port
I (ON) O (OFF) switch
Auxiliary I/O connector
Power supply jack
LEDs (left to right)
LED Meaning
LED 0 Reader has power is initialized and ready.
LED 1 Reader is communicating with the host, it flashes
as data transfer occurs.
LED 2 Reader RF is ON and searching for TAGs.
LED 3 Reader is communicating with a TAG, it flashes as
transfer occurs.
ITRF24501 Reader Quick Start Guide
11
Troubleshooting
Table 1-4
Troubleshooting
Problem Solution
Doesn’t recognize tag 1. Check to ensure antenna is con-
nected to jack on Reader.
2. Ensure Reader is connected to
your computer.
3. Ensure computer is plugged into
ac outlet and computer is turned on.
4. Ensure tag is within range of an-
tenna.
5. Access the Intermec web site
http://www.intermec.com or
http://NorBBS.Norand.com to down-
load and run the diagnostic test util-
ity PENNRFID.EXE.
6. Call Intermec Technical Support
800--755--5505 (US or Canada)
425--356--1799 (elsewhere).
Diagnostic PENNRFID.EXE Utility
Should your Reader fail to read tags, download the test utility
from the Intermec web site (http://www.intermec.com). This
utility PENNRFID.EXE is a self-extracting zip file that
includes installation instructions and a test utility to check the
operation of the Reader on a laptop or desktop computer. Refer
to the README.TXT file included in the zip file for
instructions on using the test utility.
Should the reader fail after running this utility, contact Inter-
mec Technical Support and give them the error codes you ob-
serve. They will step you through further diagnostic trouble-
shooting.
ITRF24501 Reader Quick Start Guide
12
Performance Specifications
Dependent upon operating conditions and demands expected. If
used in a normal office environment with good read conditions,
you could expect to read up to 30 tags per second. Tags located
too far away or in poor locations, with respect to interfering
objects, provides poor results.
Table 1-5
ITRF24501 Reader Specification
Criteria Range
Operating Temperature --20dto +55dC(--4
dto +131dF)
Storage Temperature --40dto +85dC(--40
dto +185dF)
Humidity 10--95% relative humidity, non-con-
densing process
Frequency 2400--2483 MHz
Tag data rates 32K bits per second
Operating Voltage 8--10 VDC
Ripple 200 mV maximum Peak to Peak
Modulation AM, On/Off key
Coding Manchester: From reader to tag
RF Output Impedance 50:w/better than 10 dB return
loss
Bus Interface Serial RS-232, RS-422
Read Range Up to 33 inches (single tag, anten-
na, and environment dependent)
Write Range Typically 70% of Read Range
Tag identification Up to 30 tags per second
Write Rate 20 ms per byte per tag
Read current 1.6A
Standby (I) 600 mA
Protocol ANSI NCTIS T6 256--2001 stan-
dard
ITRF24501 Reader Quick Start Guide
13
Table 1-5 (Continued)
ITRF24501 Reader Specification
Criteria Range
Vibration 1.0 GRMS. 10 to 500 Hz in three
axis
Channel switching 30 uS (TX on a channel, to TX on
any other channel)
Frequency stability --50 to +50 PPM
Transmitter power output 900 mW(typical) 1000 (max.) mW
@ connector. Assume 1 dB of an-
tenna and cable loss across total
passband.
Safety Approvals USA: UL Listed, C22.2 No. 950/UL
1950 (605969)
Electrical Emissions USA: FCC Part 15, Class A
RF Approval USA: 2.4 GHz Frequency FCC
15.247
Europe: 2.4 GHz Frequency ETSI
300 400
Shock 20Gs, 11 ms, half sine pulse
ESD +8 KV (indirect) +4 KV (direct); 15
KV (except conductor pin (4KV)) in
direct air discharge
Mean Time Between Failures TBD hours
ITRF24501 Reader Quick Start Guide
14
Corporate Headquarters
6001 36th Avenue West
Everett, Washington 98203
tel 425.348.2600
fax 425.355.9551
www.intermec.com
ITRF24501 Reader, Quick Start Guide-March, 2002
*962054051*
962054051 REV A

Navigation menu