Intermec Technologies RFID915IM5 Intellitag RFID Radio User Manual IM5 Module QSG

Intermec Technologies Corporation Intellitag RFID Radio IM5 Module QSG

Contents

Users Manual Part I

Installation andIM5 ReaderModuleQuick Start Guide
2 IM5 Reader Module Installation and Quick Start GuidePacking ListChecktoensurethatyoureceivetheseitems:SIntermecRIM5 Reader ModuleSCompliance StatementSWarranty CardHost CommunicationHost communication comes through the 9-pin female D-subconnector. RS-232 standards are supported as ordered from thefactory or service center.SThe maximum data rate is 115.2K baud, with 8 data bits, noparity bit, and 1 stop bit.SThe maximum RS-232 distance from the reader to the host,modem, or other physical controller interface is 50 feet (15.2meters).RS-232 ConnectionsPin Number Definition2TXD (Transmit Data) to the host3RXD (Receive Data) from the host5Ground7CTS (Clear to Send) from the host8RTS (Request to Send) to the hostPower RequirementsPower comes in from 8 to 10 volts DC. Your 915 MHz Readeruses less than 2.4 amps. Intermec supplies 9 volts DC at 2.4amps from Intermec power supply, p/n: 851-067-001.
3IM5 Reader Module Installat ion and Quick Start GuideUser I/OA general purpose I/O (Input/Output) connector provides sig-nal lines in and out of the reader allowing monitoring and/orcontrol of external devices or functions.Theconnectorforthisisa13-pinfemalecircularDIN.Themating male connector you need for mating with this is an In-termec p/n: 351-184-001.I/O Pin-outsPin Number Definition1GPIO IN02GPIO IN13GPIO IN24GPIO IN35GPIO OUT06GPIO OUT17GPIO OUT28GPIO OUT39 through 13 Ground through individual 10 ohmresistorsOutputs and inputs have 12 volt transient suppression devicesto ground at the connector. Output signals are driven by2N3904 NPN transistors (low level) with a 100 kohm pull-upto +5 volts through a silicon diode, giving about a 4.3 volt highlevel. An output can be pulled high from an external source ashigh as 12 volts. This will however tend to pull the other out-puts higher (through two 100k resistors). The low level will beabout0.1voltuptoabout30mA.Theoutputlowvoltagewillclimb higher as the sink current increases. There is no protectionon this. You need to ensure that their load won’t require thereader to sink more than 50 mA.Input signals should be 0 to +1.5 volt for a low input and +3.5to +5 volts for a high input. Each input has a 1.1 kohm resistorin series with clamping diodes, but only about 1 µAisusedun-til the input exceeds the 0 to +5 volt input range. There is also aweak (100 kohm) pull-up to +5 volt on each input.
4 IM5 Reader Module Installation and Quick Start GuideInstalling the IM5 Reader ModuleThe IM5 Reader Module requires 8-10 volts DC at 2 amps.The IF4 Serial Reader is powered through a 2-pin bulkhead bar-rel connector (Switchcraft p/n: 712A).The Reader Module supplies 9-volt 2.4 amps to this connector.Mating plugs for this connector are Switchcraft part numbers760, 760K or 761K. A cable within the PSR connects the bulk-head barrel connector, via an endplate switch, to the 2-pin Mo-lex connector on the IM5 Reader Module.IM5 Reader moduleCable connectorAuxiliary I/OConnectorRS-232 portThe IM5 Reader Module has holes along the sides that can beused for mounting. For best results, attach heat sink to case viathe screwholes in the heat sink.Screw holesIM5 Reader module
5IM5 Reader Module Installat ion and Quick Start GuideConnecting and Getting StartedFCC and Industry Canada regulations limitexposure to radiofrequency (RF) radiation. Tocomply with these regulations, operators of thisdevice must maintain a distance of at least 23 cm.(9.1 inches) from the cover on the antennaassembly (The cover on the antenna is the domeshaped surface). While the device is on, theoperator’s body and parts of the body such as eyes,hands, or head, must be 23 cm. (9.1 inches) orfarther from the cover of the antenna assembly.FCC and Industry Canada regulations also requirethat the antenna assembly of this device beinstalled in accordance with the installationprocedures to allow the operator to comply withthe limit. Use of antennas and accessories notauthorized may void the compliance of this productand may result in RF exposures beyond the limitsestablished for this equipment.
6 IM5 Reader Module Installation and Quick Start GuideAntenna Installation1Connect the antenna cable to a port. The four antenna con-nectors have lock washers and nuts to allow for panel mount-ing.2Connect a reverse SMA terminator (Intermec p/n345-004-001) to any port that does not have an antenna at-tached.Each port must have either an antenna or aterminator connected. Do not apply power to theReader unless an antenna cable or terminator isinstalled on each antenna port.Antenna ports (4)Washers (4)Nuts (4)Reverse SMAterminatorReverse SMA Antenna cableReader LED ExplanationLED Meaning0Power On1Reader communicating with host, LED flashes as data transferoccurs.2Reader searching for tags3Reader communicating with a tag, LED flashes as transfer occurs.
7IM5 Reader Module Installat ion and Quick Start GuideTroubleshootingTroubleshootingDoesn’t Recognize Tag1. Ensure antenna is properly connected.2. Ensure reader is connected to your computer.3. Ensure computer is plugged into AC outlet and computer is On.4. Ensure tag is within range of antenna.5. Call Intermec Technical Support 1-800-755-5505 (option 2).Product SpecificationsDependent upon operating conditions and demands expected. Ifused in a normal office environment with good read conditions,you could expect to read up to 60 tags per second. Tags locatedtoo far away or in poor locations, with respect to interferingobjects, provides poor results.Firmware ArchitectureFirmware Spec DetailProtocol/Compatibility Communicates in three modes: Ap-plication Peripheral Interface (API)and Basic Reader Interface(BRI).ANSI CCITS 256.2000 forAPI, part 2, part 3-1General SpecificationsReceiver Spec DetailProtocol ISO 180006BTag data rates 32 kbpsTransmitter Spec DetailProtocol IntellitagTransmitter type On/Off KeyingFrequency stability <±100 ppm from -25°to +55°CRF Antenna Connections Spec DetailNumber of antennas up to 4, electronically switchedAntenna port isolation ≥22 dB
8 IM5 Reader Module Installation and Quick Start GuideGeneral Specifications (continued)Physical Specifications Spec DetailSize 8.25 in. x 5.30 in. x 2.9 in.Weight 38.4 oz. (1.1 kg)Frequency reference Source Spec DetailFrequency of operation 902-928 MHzUsable channels 51Transmitter Spec DetailOutput power 1.00 Watt maximumOccupied frequency bandwidth <250 KHzEnvironmental SpecificationsTemperature Spec DetailOperating -4°F to +131°F(-20°C to +55°C)Storage -31°F to +158°F(-35°C to +70°C)Humidity Spec DetailOperating 95% RelativeOverall PerformanceDispatch Rates Spec DetailRFID tag identification rate 60 tags per secondRFID tag data exchange rates Read a tag containing 8 bytes of datawithin 12 mS.Perform a verified write to a tag at anaverage rate of 31 mS per byte pertag.Write Range Spec DetailWrite range Distances up to 70% of the read dis-tance under the same conditions.
9IM5 Reader Module Installat ion and Quick Start GuideReliabilitySafety and Regulatory Approvals Spec DetailReader module UL 60950-1-UL RecognizedComponent.Electromagnetic Compatibility Spec DetailReader Module EN55022 (CISPR 22) Class Bdigital emissionsEN55024 ImmunityEN61000-3-2, -3 AC PowerHarmonic Emissions and FlickerRadio Frequency Device Approval Spec DetailReader Module FCC Part 15.247Industry Canada RSS 210Global Services and SupportWarranty InformationTo understand the warranty for your Intermec product, visit theIntermec web site at http://www.intermec.com and click Service& Support. The Intermec Global Sales & Service page appears.From the Service & Support menu, move your pointer overSupport,andthenclickWarranty.Web SupportVisit the Intermec web site at http://www.intermec.com todownload our current manuals in PDF format. To order printedversions of the Intermec manuals, contact your local Intermecrepresentative or distributor.Visit the Intermec technical knowledge base (Knowledge Cen-tral) at http://intermec.custhelp.com to review technical infor-mation or to request technical support for your Intermec prod-uct.
10 IM5 Reader Module Installation and Quick Start GuideTelephone SupportThese services are available from Intermec Technologies Corpo-ration.Service DescriptionIn the U.S.A. and Canadacall 1-800-755-5505 andchoose this optionFactory Repair andOn-site RepairRequest a returnauthorizationnumber forauthorized servicecenter repair, orrequest an on-siterepair technician.1Technical Support Get technicalsupport on yourIntermec product.2Service ContractStatusInquire about anexisting contract,renew a contract, orask invoicingquestions.3Schedule Site Surveysor InstallationsSchedule a sitesurvey, or request aproduct or systeminstallation.4Ordering Products Talk to salesadministration,place an order, orcheck the status ofyour order.5Outside the U.S.A. and Canada, contact your local Intermecrepresentative. To search for your local representative, from theIntermec web site, click Contact.
11IM5 Reader Module Installat ion and Quick Start Guide
12 IM5 Reader Module Installation and Quick Start GuideCorporate Headquarters6001 36th Avenue WestEverett, Washington 98203tel 425.348.2600fax 425.355.9551www.intermec.com*962054121A*P/N: 962-054-121AIM5 Reader Module Installation and Quick Start Guidee2004 by Intermec Technologies Corporation. All rights reserved.U.S.A.