Intromedic INTROMEDIC3 MiroCam Capsule Endoscope System User Manual

Intromedic Co., Ltd. MiroCam Capsule Endoscope System Users Manual

Users Manual

Download: Intromedic INTROMEDIC3 MiroCam Capsule Endoscope System User Manual
Mirror Download [FCC.gov]Intromedic INTROMEDIC3 MiroCam Capsule Endoscope System User Manual
Document ID1476111
Application IDVimddF1SLKYx/Um5CYsIVQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize401.92kB (5024048 bits)
Date Submitted2011-06-02 00:00:00
Date Available2011-06-02 00:00:00
Creation Date2011-05-17 13:00:42
Producing SoftwareHaansoft PDF 1.3.0.407
Document Lastmod2011-05-17 13:00:42
Document TitleMicrosoft Word - User Manual_English Edition for MR1100_20110511.doc
Document CreatorHaansoft PDF 1.3.0.407
Document Author: Ballista

User Manual
User Manual
Copyright© 2007 IntroMedic Co., Ltd.
Version 1.00
MM1100-U-1105
Date : 2011-05-11
Warranty
Trademarks
MiroCam®, MiroView™, IntroMedic, and the associated logos are the
registered trademarks ® or trademarks ™ of IntroMedic Co., Ltd. © IntroMedic
Co., Ltd. July 2007.
Except as required by applicable copyright laws; any use of the IntroMedic
trademarks, or any reprinting, reproduction, modification, referencing and
translations of the User Manual, without the prior written approval of
IntroMedic Co., Ltd. is strictly prohibited.
Warranty
Every effort has been made to ensure the information contained in this User
Manual is accurate, and is believed to be correct at time of printing.
IntroMedic reserves the right to change any content contained with this User
Manual without prior notice.
IntroMedic Co., Ltd. warrants the product against defects in material and
workmanship for a period of twelve (12) months from the date of sale, unless
different local regulations apply. IntroMedic Co., Ltd. will repair or replace
products that are ascertained by IntroMedic to have defects during the
warranty period. IntroMedic Co., Ltd. is not liable for the defects occurred by
misuse, careless handling, unauthorized modifications or erroneous use, or
any use that is non-compliant with instructions detailed within this User
Manual. This includes use of the product in non-appropriate locations or
conditions. Any other warranties are neither represented here nor recognized
by implication.
To validate the warranty, please complete product registration with the local
authorized IntroMedic distributor.
Page 5
Warranty
Exclusive warranty service
The warranty service provided hereby is applicable exclusively to the
purchaser of the product. IntroMedic will only warranty the product for
purposes and usage as defined in this User Manual. Any usage not heeding
the warnings, cautions and recommended usages as defined in this manual
will nullify the warranty.
Support
For warranty or repair service please contact the local authorized IntroMedic
distributor.
For customer service or support please contact your point of purchase or
IntroMedic Co., Ltd. Service agreements are only applicable to products of
IntroMedic Co., Ltd.
IntroMedic Customer Service
TEL: 82-2-801-9300
FAX: 82-2-801-9330
http://www.intromedic.com
E-mail: helpdesk@intromedic.com
Safety
Non-compliance with the user’s manual, unauthorized modifications of the
product or replacement of parts, and/or opening of the product casing is
prohibited and may be hazardous.
Declaration on translation of labeling
Based on buyer's request, IntroMedic will provide the labeling, such as ID
label, Instruction for use and other promotional materials, which is translated
into the national language(s) of European countries. And it will be evaluated
by the local language expert, and will be confirmed by the native speaker of
the local language.
Page 6
Contents
CONTENTS
1. SAFETY INFORMATION
1.1
1.2
1.3
1.4
Warnings
Symbols for Safety
Function Symbols
Notes for Safe Use
2. SYSTEM OVERVIEW
2.1
Intended Purpose
2.2
2.3
2.4
Observable Diseases
Product Lifetime
Product Specification
3. PERFORMING CAPSULE ENDOSCOPY
3.1
3.2
3.3
3.4
3.5
3.6
3.7
General Comments
Safety Warnings
Examination Preparation
Patient Preparation
Sensor Placement & Capsule Ingestion
Uploading Images
Receiver Management – Post Procedure
16
17
Page 7
Contents
4. USING MIROVIEW™
4.1
4.2
4.3
MiroView™ H/W Specifications
Overview – MiroView™ Server
Overview - MiroView™ Operator
10
4.4
4.5
4.6
4.7
Overview - MiroView™ Client
Overview - MiroView™ Viewer
Performing Capsule Endoscopy
How to import MiroView™ 1.0 files
18
31
32
52
5. USING MIROVIEW™ RTV
5.1
5.2
Overview
Using MiroView™ RTV
6. USING WIRELESS MIROVIEW™ RTV
6.1
6.2
Page 8
Overview
Using Wireless MiroView™ RTV
1
Safety Information
Safety Information
1- 2
Chapter 1
Chapter 1
Safety Information
1. SAFETY INFORMATION
1.1 Warnings
MiroCam® has been manufactured to conform with the International
Standard for Medical Electrical Equipment: General Requirements for
Safety IEC 60601-1, together
with the Collateral Standard for
Electromagnetic Compatibility Requirement and Tests IEC 60601-1-2.
MiroCam® has been manufactured to conform to the electric shock, fire
and mechanical hazard standards as defined in CAN/CSA C22.2
NO.601.1.
Based on request of the buyer, IntroMedic will provide the labeling, such
as ID labels, and the User Manual in the national language(s) of
European countries. Translated documents will be evaluated by a local
language expert, and will be confirmed by a native speaker of the
respective national language.
Safety Symbols: The User Manual incorporates various safety symbols
to ensure safe and correct use of the product and to prevent any personal
injury or property damage. These symbols are defined in the following
table:
WARNING
WARNING indicates a potential hazard that, if not avoided, could
result in serious personal injury or damage to the product.
CAUTION
CAUTION indicates a potential hazard that, if not avoided, could
result in minor personal injury or damage to the product.
NOTE
NOTE does not indicate potential hazards as in Caution or
Warning, but contains important information regarding the
installation, operation or maintenance of the product.
1-3
Safety Information
Chapter 1
1.2 Symbols for Safety
This section describes a set of symbols that the IEC (International
Electrotechnical Commission) has established for medical electronic
equipment to classify connections and warnings of any potential hazards.
IEC 348: Notice for the user to pay special attention to the
following details
IEC 878-02-03: Indicates that this is classified into Type BF
equipment
EN 980: Denotes Date of Manufacture
EN 980: Denotes Address of Manufacture
IEC60601, ANNEX D: Denotes “ON” status of main power
switch
IEC60601, ANNEX D: Denotes “OFF” status of main power
switch
SN
EN 980: Denotes serial number
IEC 417-5031: Denotes DC (Direct Current)
IEC 417-5032: Denotes AC (Alternating Current)
Denotes Ampere, the unit of current
Hz
Denote Hertz, the unit of Frequency
Denotes Volt, the unit of Voltage
IEC 417-5021: Denotes potential equalization terminal
Single Use Only
Use by date
1- 4
Chapter 1
Safety Information
1.3 Function Symbols
1.3.1
MiroView™ Function Symbols
The following table describes symbols or icons used in the
MiroView™ software.
Symbol
Description
Connect to the receiver
and open receiver control
screen.
Symbol
Description
Open the report screen to
create a patient capsule
endoscopy report.
Open screen to export
Open the patient data
(save externally) selected
screen.
image data for a specific
patient.
Open screen to review for a
Select and save an image
specific patient
being reviewed.
Place a landmark in an
Open the Color
image being reviewed.
Enhancement Window
Show images in full screen
Time Display
Show images in the Single
Show images in the Dual
Screen
Screen.
Show images in the Quad
Show images in the Range
Screen.
Mode.
Show images in the Map
View
Play all images.
Play the selected images
SGIB - Play the images
only. View images via
captured via Suspected GI
Express Mode function.
Bleeding function.
1-5
Safety Information
Symbol
Chapter 1
Description
Description
Move to the previous
Move to the previous
image.
captured image.
Play images in reverse
order.
Play
Move to the next captured
image.
Stop playback of images.
Play images in sequential
order.
Move to the next image.
Open the Positioning
Open the Comparison
Window
Window
Expand/Shrink Capture
Box
Show Circumference
Markers
Add a Line on the image
Color Palette
Redo the action
1- 6
Symbol
Statistic Box
Add a Circle on the image
Delete selected Circle /
Line
Undo the action
Check selected captured
images
Chapter 1
Symbol
Safety Information
Description
Uncheck selected
captured images
Review
Export Review
Export Captured Images
with EXMIF
Symbol
Description
Print
Save as PDF
Open PACS function
(Registered User Only)
Export Captured Images
as Image / Video /
MiroVideo
Export Segments as
Export Case as Video /
Image / Video / MiroVideo
MiroVideo
Select the area as a
Deselect the area from
Segment
Segment
1-7
Safety Information
1.3.2
Chapter 1
MiroCam® Receiver Function Symbols
Symbol
Description
SIG
Indicates status of signal from capsule
Green : Signal is being received from capsule
Yellow : Signal is not being received from capsule
INI
Initialization status of Receiver Unit
Green : Receiver is initialized
Yellow : Receiver is not initialized
BAT
1- 8
Battery Status
Green : Fully charged
Yellow : Not charged
Chapter 1
Safety Information
1.4 Notes for Safe Use
Follow the safety instructions included in this User Manual and clinical
precautions advised by the medical professional.
The manufacturer is not liable for harm or damage caused by improper,
unauthorized, unprofessional or inexpert use of the device and/or
product.
IntroMedic Co., Ltd. is NOT responsible for physical harm or
equipment problems caused by the user’s careless operation or
mismanagement of the device and/or product.
Users MUST have read and understood the User Manual. ONLY
trained
and
qualified
medical
professionals
or
authorized
representatives of IntroMedic Co., Ltd. may operate the system.
User Manual must ALWAYS be with the equipment. This is the USER’S
RESPONSIBILITY.
CAUTION: foreign substances including water, cleaning fluids,
disinfecting cleanser and such substances may harm the equipment,
and should not enter the equipment.
ONLY authorized personnel may perform repairs. Never attempt to
open covers, panels or casings.
DO NOT crease, bend, fold or twist the data cables. Take care to guard
them against mechanical stress (e.g. wheels or heels)!
The sensor pads, receiver, data cables, and capsules must not be
exposed to mechanical shock (e.g. by dropping). Any damage caused
that way will void the product warranty.
CAUTION: Damage/injuries to the sensor pad or data cable may
cause a safety hazard. Damaged items MUST be repaired
IMMEDIATELY.
DO NOT handle fluids in the vicinity of the system.
When using a cart purchased elsewhere, ensure the brake or latch
guard is in use to prevent the wheels from rolling.
1-9
Safety Information
Chapter 1
DO NOT USE in moist or damp places.
DO NOT operate the equipment with wet hands.
Avoid using the equipment in extreme temperatures or humid
environments.
DO NOT keep the equipment or carry out the procedure in places such
as areas exposed to direct sunlight, vicinity of heaters, vicinity of
chemical materials or gases, areas moist/damp or dusty, or poorly
ventilated areas.
DO NOT disassemble or open the equipment without permission. This
will invalidate the warranty.
DO NOT carry out the procedure in areas with high vibrations or in
environments where high electro-magnetic waves are generated.
DO NOT pull out the power cord by grabbing the cable. When
disconnecting the power cord, grasp the plug, and pull out.
This
prevents short-circuits, disconnection, or cord damage.
CAUTION: Verify that the power voltage supplied from the power
receptacle matches with the voltage the system requires. Check
Voltage and Frequency on the AC/DC adaptor.
CAUTION: Turn off the power switch before connecting the sensor pad.
DO NOT discard sensor pads, cables and connectors with general
waste. Discard separately as industrial or medical waste.
CAUTION: Discard the battery according to the regulations of industrial
waste.
DO NOT discard with general waste.
DO NOT carry out the procedure simultaneously with other procedures
using medical products or equipment.
DO NOT use for purposes other than medical treatment.
DO NOT connect the USB cable to the receiver while the receiver’s
data cable and sensor pads are still connected
DO NOT charge the receiver while the receiver’s data cable and
sensor pads are still connected.
1- 10
Chapter 1
Safety Information
Connect USB cable to receiver only after mounting it on charger.
DO NOT install any other programs onto the workstation utilized for
review and diagnosis of patient image data (i.e computers with the
MiroView™ software).
The capsule is disposable and should not be reused.
The capsule and sensor pads are medical waste, and should be
disposed of according to local regulations or WEEE directive on waste
disposal.
Only use the capsule, receiver, data cables and sensor pads in the
medical environment condition.
All products connected with the MiroCam® Endoscope system must be
compliant with requirements of IEC60950-1 or UL certifications.
Check the outer surface of the endoscope for rough surfaces, sharp
edges, or protrusions which may cause a safety hazard.
Please don’t try to cut the label.
1-11
Safety Information
1.4.1
Chapter 1
Environmental Conditions for Operation
Temperature
: +0 ℃ - +40℃
Relative humidity
: 45% - 75%
Atmospheric pressure
: 700hPa to 1060hPa
WARNING DO NOT operate the equipment in the vicinity of
generators, power stations, X-ray devices, and
broadcasting stations where high levels of electro-magnetic
waves are generated. The electro-magnetic waves can
cause equipment malfunctions.
CAUTION If the equipment has been brought in from a cold
environment (stock room, airfreight) into a warm room,
initial activation should take place after a few hours, to
allow for temperature adjustment and balance and
evaporation of condensed humidity.
WARNING DO NOT operate the equipment in the vicinity of heat
sources, strong electric or magnetic fields (close to a
transformer), or near instruments generating highfrequency signals.
WARNING Do not use MiroCam® alongside or together with medical
devices or procedures involving electrical currents.
Do not use MiroCam® with h.f. surgical equipment. It may
result in burns at the site of the electrodes and possible
damage to the capsule and receiver.
Do not use the unit in close radius (within 1 m) of short
wave or microwave therapy equipment. It may produce
instability in the captured image.
WARNING This device is a Class B device according to EN60601-1-2
standards. This equipment can cause radio interference in
residential areas. In this case, the owner (or operator) can
be held responsible to take appropriate measures or take
proper measures for compensation.
1- 12
Chapter 1
1.4.2
Safety Information
Safety Precaution
CAUTION -
CAUTION
Make sure the environment is without interference from
electromagnetic fields.
- Make sure the environment is without noise and
vibration.
- DO NOT carry out the procedure while using other
equipments, devices or products.
- The instruction for use of the sensor pads MUST be
observed.
- DO NOT use on patients with pacemakers or
defibrillators.
DO NOT use the capsule if the package is unsealed.
DO NOT reuse a used capsule.
To prevent unexpected accidents like fire or explosion, do not use any
product near or in the presence of inflammable or ignitable substances.
DO NOT disassemble the equipment case nor open the cover. In case
service is required, please contact IntroMedic customer support or
local point of sale immediately.
Only the accessories authorized and designed by IntroMedic Co., Ltd.
should be used with this equipment. Faults resulting from the usage of
unapproved or inappropriate accessories are not guaranteed against.
This equipment may have an effect on other products or be effected by
other products.
Follow your doctor’s instructions and abide by the guidelines in the
User Manual.
DO NOT try to upload the data while the data cables are still
connected to the receiver.
DO NOT charge the rechargeable battery in the receiver while the data
cable and sensor pads are still connected to the receiver.
1-13
Safety Information
Chapter 1
Stay away from high frequency radiation sites (such as high voltage,
radar, installation power plants, MRI, CT or electric blankets etc.)
during your capsule endoscope procedure. (It may result in serious
side effects requiring an emergency operation.)
In case of any symptoms of abdominal pain, vomiting, fever, heart
trouble, dizziness or seizure during or after the capsule endoscope
procedure, please notify your doctor.
Always check the connection between the receiver and the data cable.
Always check that the battery in the receiver is fully charged before
use.
DO NOT use the capsule if the package is unsealed.
After ingesting the capsule, always check whether the capsule has
been e xcreted.
Prior to undergoing the capsule endoscopy procedure, patients with
diabetes must be informed via a medical professional regarding
appropriate medication & dosage.
For more accurate data and better analysis, patients can have solid
food for lunch, but must have liquid food for dinner on the day prior to
the procedure. The patient must fast for 11 hours prior to ingesting the
capsule.
If recommended by the physician, the patient may take a laxative prior
to the procedure.
DO NOT smoke for at least 12 hours prior to the capsule endoscope
procedure.
DO NOT apply body lotion before the procedure.
DO NOT bite the capsule.
Avoid excessive physical activity during the capsule endoscope
procedure.
4 hours after ingesting the capsule, patients may have liquid food.
It is recommended to drink mineral water (non-colored liquid)
1- 14
Chapter 1
Safety Information
frequently, so that it may raise the possibility to take much better
quality of the image.
When undergoing the capsule endoscope procedure, DO NOT make
physical contact with another person undergoing the same procedure.
During operation of the receiver, DO NOT touch the receiver, or get the
receiver wet.
Only use the provided batteries, and never remove the battery from the
receiver during the procedure.
During upload of the data recorded in the receiver to the workstation,
avoid disconnecting the USB. This may damage the patient’s data.
Always confirm that the USB is connected by checking the Receiver
screen on the MiroView™ software.
Always check the AC Power range before use the workstation.
DO NOT touch AC Power code with wet hands.
DO NOT open the receiver bag or touch receiver outside of the
hospital.
This device is intended for patient over the age of 18.
WARNING The Capsule takes a picture for 11 hours and gets naturally
WARNING
excreted in about 24 hours under normal conditions. If the
capsule has not been excreted from the patient within 72
hours, patient should contact the physician. After
examining, the physician may need to perform a surgical
operation or treatment to remove the capsule.
Before moving the system, always make sure to disconnect
the monitor from the main system, and then safely move
the main system and monitor separately. Connect the main
system and monitor only after the hardware is fully
installed, secure and stable.
1-15
Safety Information
1.4.3
Chapter 1
Cleaning and Maintenance
System and accessories
All products should be cleanly maintained. For cleaning, rub them
lightly with a soft cloth wet with warm water at least once a week.
Do not use organic solvents such as lacquer, thinner, ethylene and
oxide because they can damage the equipment. Be careful that
foreign substances do not enter the main system when cleaning.
ALWAYS operate the equipment under sanitary environmental
conditions. DO NOT use heat or gas for disinfection of the capsule.
Service Document
If required, or upon request, the local IntroMedic Distributor (authorized
IntroMedic Representative) may provide block diagrams, lists of spare
parts, descriptions, adjustment instructions or other related information
which may help qualified technical personnel in repairing specified
parts of the equipment which have been defined repairable by
IntroMedic Co., Ltd. .
Moving the Equipment
CAUTION when moving equipment.
WARNING: Excessive impact/shock causes internal damage.
If wiring is connected/disconnected when moving, check the exact
wiring status after moving.
If damage to the equipment is discovered after moving, immediately
contact IntroMedic or local Distributor.
1- 16
Overview & Intended Usage
Overview & Intended Usage
2- 2
Chapter 2
Chapter 2
Overview & Intended Usage
2. SYSTEM OVERVIEW
MiroCam® is an orally ingested capsule endoscope designed to capture
and wirelessly transmit images of the lining of the small intestine.
Captured images are viewed via the MiroView™ software for diagnosis of
diseases related to the small intestine.
The MiroCam® capsule endoscope system consists of the MiroCam®
capsule, MiroCam® receiver, MiroView™ software, and accessories.
2.1 Intended Purpose
MiroCam® is intended for visualization of the small bowel mucosa as an
adjunctive tool in the detection of abnormalities of the small bowel. The
device captures images of the small bowel with a wireless camera
contained in a capsule. This device includes an ingestible capsule
(containing a light source, camera, transmitter, and battery), an electrode
array, a receiving/recording unit, a data storage device, computer
software to process the images (MiroView™), and accessories.
2-3
Overview & Intended Usage
2.1.1
Chapter 2
Contraindications
Not intended for patients with known or suspected gastrointestinal
tract obstructions, perforations, strictures or fistular.
Not intended for patients who have difficulty ingesting food or pills
(dysphagia).
Not intended for patients who have difficulty communicating.
Not intended for patients with indigestion, or slow gastric emptying.
Not intended for patients who may be affected by electromagnetic
radiation, such as pregnant women, infants, and patients with heart
disease or epilepsy.
Not intended for patients with diverticulosis in the Small Bowel.
Not intended for patients who are recommended against having the
procedure by a Physician.
Not intended for patients with pacemakers and/or defibrillators.
This device is intended for patient over the age of 18.
2.2 Observable Diseases
2.2.1
2.2.2
2- 4
Obscure gastrointestinal bleeding (OGIB)
Angioectasia
Meckel diverticulum
NSAIDs
Crohn’s Disease
Chapter 2
2.2.3
Overview & Intended Usage
Small Bowel Tumors
Polyps
Peutz-Jeghers Syndrome
Familial adenomatous polyposis
Lymphoma
Carcinoid
Gastro-Intestinal Stromal Tumor (GIST)
Lipoma
Hemangioma
2.2.4
Inflammation
Intestinal Tuberculosis
Typhoid Fever
Angeitis
Amyloidosis
Eosinophilic enteritis
2.2.5
Celiac Disease
2.2.6
Behcet’s Disease
2.2.7
Cowden Disease
2.2.8
Cronkhite-Canada Syndrom
2-5
Overview & Intended Usage
2.3 Product Lifetime
2.3.1
Maximum Storage Time of MiroCam® Capsule
MC1000-C : 1 Year
MC1000-F : 1 Year
MC1000-G : 1 Year
2.3.2
MiroCam® Receiver, MR1000
2- 6
MiroCam® Receiver Battery : 4.62 Year
Chapter 2
Chapter 2
Overview & Intended Usage
2.4 Product Specification
2.4.1
MiroCam® Capsule
Component
Component
Capsule
Model Name
Quantity
MC1000
1 Piece (Optional)
MC1000-F
MC1000-G
Sensor Pads
MC1000-S
10 Piece
Specification
Item
Specification
Capsule Unit
Size
11 X 24 mm
(MC1000,
Weight
3.4 ± 0.05g
Frame Rate
3 frame/sec
Field of View
150 degrees
Battery Life
12 hours
Pixels
102,400
Lighting
6 LEDs
Communication
Human
Method
Communication
MC1000-F,
MC1000-G)
Body
2-7
Overview & Intended Usage
2.4.2
Chapter 2
MiroCam® Receiver
Component
Component
Model Name
Receiver Unit
MR1100
1 piece
Battery Pack
MR1100-B
2 piece
Data Cable
MR1000-D
1 piece
Receiver Bag
MR1000-G
1 piece
System Carrying Case
MR1000-A
1 piece
Battery Charger
MR1000-C
1 piece
Adaptor
MR1000-T
1 piece
Power Code
MR1000-P
1 piece
Measuring Tape
MR1000-M
1 piece
USB Cable
MR1000-U
1 piece
Specification
Item
2- 8
Quantity
Specification
Receiver Unit
Battery Life
12 Hours
(MR1100)
Size
83.5 X 138 X 28 mm
Weight
350g(including Battery)
Chapter 2
Overview & Intended Usage
Item
Specification
Battery Pack
Type
Lithium-Ion storage cell
(MR1100-B)
Capacity
10400mA
Voltage
3.6V
Recharging Time
Approx. 4 hours
Size
73.8 X 84.3 X 21.4mm
Data Cable
Channel
(MR1000-D)
Length
90cm
Receiver Bag
Size
100 X 190 X 55mm
Size
480 X 350 X 100mm
Battery Charger
Power Source
Adaptor
(MR1000-C)
Size
135 X 75 X 105mm
Weight
285g
Adaptor
Weight
231g
(MR1000-T)
Power Rating
AC100~240V/ 50~60Hz
Power Code
Length
1.5m
Length
1.5m
(MR1000-G)
System Carrying
Case(MR1000-A)
(MR1000-P)
Measuring Tape
(MR1000-M)
2-9
Overview & Intended Usage
2.4.3
Chapter 2
MiroCam® Software
Component
Component
2- 10
Model Name
Version
MiroView™ Workstation
MiroView™
2.5
MiroView™ RTV
MiroView™ RTV
1.0
Wireless MiroView™ RTV
Wireless MiroView™ RTV
1.0
3
Performing Capsule Endoscopy
Chapter 3
3- 2
Performing Capsule Endoscopy
Performing Capsule Endoscopy
Chapter 3
3. PERFORMING CAPSULE ENDOSCOPY
3.1 General Comments
This chapter describes how to operate and control MiroCam®
capsule endoscope system.
Installation and initial operation must be done by an Authorized
IntroMedic Service Technician.
3.2 Safety Warnings
WARNING Before turning on the system, check the environment
condition for MiroCam® capsule endoscope system.
CAUTION In case the system has been brought from cold
CAUTION
CAUTION
environment (stock room or airfreight) into a warm room,
you should first switch on it after some hours for
temperature balance and removing of condensation
humidity (Risk of leakage current).
For the electrical safety, make sure that peripheral
equipments (external PC, Monitor, printer etc) should be
connected to wall socket of independent power supply with
a perfect ground. Particularly make sure whether or not
those peripheral equipments should be authorized for
medical usage.
DO NOT touch the dome of the capsule.
CAUTION if SIG indicator of the Receiver turns yellow after ingesting
CAUTION
NOTE
the capsule, immediately contact the physician.
If SIG indictor of the Receiver does not turn green when the
patient holds the capsule by the gold bands, immediately
stop the procedure.
If images of the small bowel are not captured during the
procedure, ensure the capsule has been excreted by the
patient and perform procedure again.
3-3
Chapter 3
Performing Capsule Endoscopy
3.3 Examination Preparation
The following steps (3.3.1 to 3.3.4) explain the process to initialize the
receiver and register patient data for the capsule endoscopy procedure.
For more information see section 4.2.
3.3.1
Start System
Turn on power of MiroCam® workstation.
Click
Insert the ID and password and click
icon to start the MiroView™ 2.0 Operator.
icon.
WARNING Before starting the system, check the power rating for the
workstation.
3.3.2
Initialize the Receiver
Connect the smaller connector of USB Cable to Receiver unit.
Connect normal connector of USB cable to workstation.
Turn on the power of the Receiver unit.
Click
icon in MiroView™ 2.0 Operator.
Click
icon in MiroView™ 2.0 Operator.
After completing the required fields, click the
save the patient information onto the Receiver.
3- 4
button to
Performing Capsule Endoscopy
Chapter 3
Note Before execute MiroView™ 2.0 Operator, connect USB
cable to MiroCam® Receiver unit.
WARNING If MiroCam® receiver unit is initialized, any patient data
stored on the device will be deleted permanently.
3.3.3
Receiver Preparation
Connect battery to the Receiver unit.
Insert pins on back side of the Receiver unit in the slots on the
battery.
Press battery to receiver until clasp locks battery in place.
Turn on power switch of receiver unit.
Check battery indicator (BAT) of upper side of receiver unit. If
battery is fully charged, light will be green. If light is not green,
charge the battery.
Check initialization indicator (INI) of upper side of receiver unit.
Prior to beginning a procedure, this light must be green.
Connect data cable to receiver unit.
Indicator
SIG
INI
BAT
Description
Indicates status of signal from capsule
Green : Signal is being received from capsule
Yellow : Signal is not being received from capsule
Initialization status of Receiver Unit
Green : Receiver is initialized
Yellow : Receiver is not initialized
Battery Status
Green : Fully charged
Yellow : Not charged
WARNING DO NOT do begin procedure when receiver unit’s battery
indicator is not green. This indicates battery is not fully
charge or out of order, and patient data may be lost.
3-5
Chapter 3
Performing Capsule Endoscopy
3.4 Patient Preparation
Provide the patient with the following instructions to prepare for the
capsule endoscope procedure.
3.4.1
Patient Preparation
One day prior to the capsule endoscope procedure
On the day of capsule endoscope procedure
After arriving in a hospital at the appointed time, the patient
should submit an examination permission form and check in.
After ingesting capsule endoscope
3- 6
Lunch: Patient can have a normal mean around noon, followed
by a liquid diet as instructed by the physician.
The patient should fast for at least 12 hours prior to the
procedure. Patient may only drink water (no food or other
beverages such as milk or coffee).
The patient should not take any medications two hours before
ingesting the capsule endoscope.
Male patients may need to shave area, as advised by
physician or nurse.
Patient should stop taking iron supplements 1 week before the
capsule endoscope procedure, and should not ingest any
medicine at least 2 hours prior to the procedure.
Diabetic patients need to follow any changes to insulin dosage
as prescribed by the physician.
Physician is recommended to prescribe patient a laxative such
as PEG or Sodium Phosphate. Patient should ingest laxative
12 hours prior to procedure.
Physician is recommended to prescribe patient an anti-foaming
agent (such as simethicone), to reduce bubbles in the GI tract.
This should be ingested after the laxative.
The patient should abstain from smoking 12 hours before the
procedure.
On the day of the capsule endoscope test, the patient should
wear comfortable and loose cloths. One-piece clothing should
not be worn.
Prior to the procedure, do not apply any lotions or perfumes.
The patient should refrain from taking any food or drink two
hours after ingesting the MiroCam® capsule endoscope. Water
is permitted after two hours.
Performing Capsule Endoscopy
Chapter 3
The patient can start with light food after 4 hours. When the
examination is complete, the patient can start having normal
meals.
In case of any abdominal pain, nausea or vomiting after
ingesting the MiroCam® capsule, the patient should contact
physician or nurse immediately.
3.5 Sensor Placement & Capsule Ingestion
Following is the detailed procedure required to correctly administer the
capsule endoscope procedure.
3-7
Chapter 3
3.5.1
Performing Capsule Endoscopy
Connecting Sensor Pads
After attaching sensor pads to the data cables, attach the sensor pad
correctly to each area as shown below.
Xiphoid process Line
Pelvic Line
3- 8
Performing Capsule Endoscopy
Chapter 3
3.5.2
Xiphoid
process Line
Pelvic
Line
Attach sensor pads according to the number on the data cable.
- Locate the center between the umbilical and the xiphoid process.
From this center point, attach the sensor to the distal point on
the right flank of the patient’s body.
- Place the sensor pad on the xiphoid process line, directly below
the right clavicle.
- Place the sensor pad on the xiphoid process line, directly below
the left clavicle.
- Locate the center between the umbilical and the xiphoid process.
From this center point, attach the sensor to the distal point on
the left flank of the patient’s body.
- Place the sensor pad on the right pelvic line, 2 cm behind
sensor #1.
- Place the sensor on the right inguinal line, 2 cm to the outside of
sensor #2.
- Place the sensor on the right inguinal line, 2 cm to the outside of
sensor #3.
3-9
Chapter 3
Performing Capsule Endoscopy
Place the sensor pad on the right pelvic line, 2 cm behind
sensor #4.
Place the sensor directly below the right clavicle.
CAUTION The numbering of the data cables and sensor pad must
CAUTION
WARNING
match the specified area. Please follow the numbering
sequence appropriately.
To prevent entanglement of the data cables during
procedure, organize cables and place appropriately in cable
bag.
Correct image signal may not be obtained if a sensor pad is
not in direct, immediate contact with the skin. Ensure the
sensor pads are in direct contact with the skin. Shaving
may be required for male patients.
The pictures below show the sensor pads attached in the correct locations.
3- 10
Performing Capsule Endoscopy
3.5.3
Chapter 3
Removing Capsule from Packaging
While holding the MiroCam® upside down, peel off the sterilized
packaging cover.
3.5.4
Removing the Case
Turn the package over, the MiroCam® case will slip out of the
packaging. While holding the MiroCam® case, open the lid.
3.5.5
Removing the Capsule
Grip capsule with right hand, and remove from cast. Do not touch the
dome of the capsule.
3-11
Chapter 3
Performing Capsule Endoscopy
Make sure that the capsule packaging is not damaged in any way.
When removed capsule from case, the capsule should be flashing.
CAUTION Do not use a capsule endoscope when the packaging or
the capsule is damaged.
Check if the front of the capsule is flashing when it is removed
from the case
After washing hands, patients should grip the gold section of the
capsule between the thumb and the forefinger of the both hands.
NOTE After turning the receiver power on, if a signal is not received
by the receiver within 50 seconds (i.e. the SIG indicator does
not turn green), the SIG indicator will flash orange and the
receiver will make a ‘beep’ ‘beep’ warning sound. This will
occur until a signal is received or the power is turned off.
In this case, you must begin the procedure immediately or
turn the receiver off until ready to begin the procedure.
3- 12
Performing Capsule Endoscopy
3.5.6
Chapter 3
Checking Operation of the Receiver and Signal Reception
After the patient holds the capsule as detailed above, the signal
indicator on the receiver is green and signal indication melody is
generated.. If signal indicator is yellow, there is no signal being
received from the capsule.
Switch on the receiver.
Check if the battery indicator (BAT) at the top of the receiver shows
that the battery is fully charged. The battery indicator on the
receiver should be green.
Check if the initialize indicator (INI) at the top of the receiver shows
that initialization is complete. The INI indicator on the receiver
should be green.
Connect the data cable to the MiroCam® receiver.
After patient grasps capsule by opposing gold bands (as detailed
in picture above, check the SIG indicator on the receiver is green
and signal indication melody is generate.
CAUTION If the battery indicator on the receiver shows that the
CAUTION
battery is not fully charged, do not start the endoscopy
procedure. The battery may be depleted during the
procedure and images may not be saved properly.
Please be noticed to confirm the shape and the direction of
the connector when you connect the data cable to
MiroCam® Receiver, since it may cause cable damage
problem.
3-13
Chapter 3
3.5.7
Performing Capsule Endoscopy
Ingesting the Capsule
After checking if the signal indicator on the receiver is green, ingest
the capsule with water.
CAUTION Do NOT bite the capsule while ingesting.
3- 14
Performing Capsule Endoscopy
3.5.8
Chapter 3
Checking and Wearing the Receiver
After ingesting the capsule, make sure that the SIG indicator is
green.
Place the receiver in the bag.
Organize the contents of the bag so that the cables are not
entangled.
Adjust cables, and place excess in cable bag.
Adjust the bag strap as needed.
Capsule endoscopy procedure will be complete after 11 hours.
CAUTION Patient should not touch receiver during the procedure. This
CAUTION
may lead to loss of image data.
During the procedure the SIG indicator should be green.
In this case, check data cable to ensure it is securely
inserted and check the sensor pads to ensure these are
fixed to the body.
3-15
Chapter 3
Performing Capsule Endoscopy
3.6 Uploading Images
Once the capsule endoscopy procedure is complete, upload image data
from the receiver to the workstation and start diagnosis of the data using
MiroView™ 2.0 Software.
3.6.1
Transferring and Checking image data
Switch on the workstation.
Click the
icon on the desktop to launch MiroView™ 2.0
Operator.
When the login window appears, enter the user ID and password,
and then click the
button.
Connect the smaller end of the USB cable to the receiver.
Connect the other end of the USB cable to the workstation.
Click the
When the image data in the MiroCam® receiver is successfully
button in MiroView™ 2.0 Operator.
uploaded, execute MiroView™ 2.0 client to review and report.
WARNING For more information on using MiroView™, please refer to
Chapter 4, Using MiroView™ 2.0.
3- 16
Performing Capsule Endoscopy
Chapter 3
3.7 Receiver Management – Post Procedure
3.7.1
Cleaning
Remove data cable from receiver unit.
Capsule and sensor pads should not be reused.
To clean the MiroCam® Receiver unit and Workstation, dampen a
soft cloth with warm water or with a commercial, nonabrasive
cleaner (or a mild soap or detergent solution) and wipe the exterior
surface lightly. Do not allow any liquids to come in contact with the
power connector, cable connector or switches. Do not allow any
liquids to penetrate connectors or openings in the system cover.
Cleaning of the system and accessories should be conducted at
least once a week.
CAUTION Do not immerse the MiroCam® capsule endoscope system
or its accessories in liquid or clean with caustic or abrasive
cleaners. Do not spray or pour any liquid on the system or
its accessories. Do not use the organic solvents such as a
lacquer, thinner, ethylene and oxide because they can
damage the equipment. When cleaning the data cables, do
not use the cleaning tools such as brush and sandpaper.
3.7.2
Charging Battery
Battery must be recharged after every procedure.
Battery can be individually recharged or with receiver unit.
Battery must be recharged in battery charger.
If two batteries are inserted in charger, the batteries will
automatically consecutively charge (not simultaneous).
3-17
Chapter 3
3- 18
Performing Capsule Endoscopy
Connect adapter DC cable to battery charger.
Connect AC power code to adaptor.
Connect AC power code to AC consent or multi-tap.
Battery charger indicator lights:
n Battery is charging when green light is blinking
n Battery is fully charged when light is solid blue
n Battery is not-charging if light is yellow
n Note: second battery in charger will automatically begin
charging once first battery is fully charged.
Performing Capsule Endoscopy
Chapter 3
Waiting
Charging
Charging
Charged
WARNING If the indicator on the battery charger is blinking yellow
WARNING
WARNING
there is a bad connection. Please disconnect the battery
from the battery charger and try again.
Only use batteries provided by IntroMedic. Usage of
inappropriate batteries can cause serious damage to the
receiver.
Recharge the MiroCam® receiver batteries with the
adaptor and the battery charger only from IntroMedic.
Improper adaptors and battery chargers cause serious
damage.
3-19
Chapter 3
Performing Capsule Endoscopy
WARNING Try not to contact the metallic terminal board of batteries
WARNING
WARNING
WARNING
WARNING
3- 20
with conductive objects or human body. It can cause an
electric shock or damage and/or breakage of the
batteries.
Do not use the batteries with visible surface damage on.
Usage of damaged batteries can result in leakage of
contents of the batteries.
To avoid the risk of explosion, keep batteries away from
fire.
Treat the batteries carefully from serious impact or shock.
This can cause serious damage to the batteries.
Do not expose the batteries to liquids. This can cause
serious damage.
Using MiroView™
Chapter 4
4- 2
Using MiroView™
Using MiroView™
Chapter 4
4. USING MIROVIEW™
MiroView™ is a computer software program that aids in diagnosis of disease
of the small bowel via displaying images obtained from the MiroCam®
capsule.
MiroView™ version 2.5 is an update to the MiroView™ version 1.0. The
updated functionalities and user interface further enhance the efficiency and
effectiveness of the MiroCam® capsule endoscopy procedure.
Following is a list of new & updated features:
- User Interface
v MiroView™ enables adjustable resolution, to appropriately fit to the
screen size.
v MiroView™ has been designed with a dark background to reduce eye
strain.
v MiroView™ provides intuitive and unified icons so that the user can
adapt quickly.
- Reporting Tool
- Express View
- Range View
- Network Support
- Account Management
- Multi-Review / Report Generation Support
- Multi-Receiver Management Support
The workstation where the MiroView™ is installed properly has icons for four
applications on the Desktop folder: MiroView™ Client, MiroView™ Operator,
MiroView™ Server, and MiroView™ Viewer. However this manual will not
explain how to use the MiroView™ Viewer. For additional information for
MiroView™ Viewer, please refer to the MiroView™ Viewer Instruction Manual.
To get the installation procedure for MiroView™, refer to the MiroCam®
Service Manual.
4-3
Chapter 4
Using MiroView™
MiroView™
MiroView™
MiroView™
MiroView™
Client
Operator
Server
Viewer
This program is
used for reviewing the
images
from
the
MiroCam®
capsule
and generating a
patient report. The
MiroView™
Server
should be started
prior to starting the
MiroView™ Client.
This program is
used for managing
the
receivers
(initialize, upload etc.)
and managing user
accounts.
The
MiroView™
Server
should be started
prior
to
starting
MiroView™ Operator.
The server stores
the patient data files.
Start the MiroView™
Server
prior
to
starting MiroView™
2.0 or MiroView™
Operator.
The
MiroView™
Viewer is used for
reviewing the images
exported from the
MiroView™ Software;
EXMIF
or
JPEG
images.
Functions:
Functions:
Functions:
Functions:
- List Mode
- Review Mode
- Report Mode
- Export Mode
- Image Atlas
- SGIB
(Suspected
GI Bleeding)
- Positioning Window
- Network connectivity
- Multi-Review
- Express View
- Range View
- Map View
- GI Dictionary
- Finding / Diagnosis
Information
- Input Patient
Information
- Receiver
Initialization
- Upload Data from
Receiver
- Data Backup
- Account
Management
- Network connectivity
- DB, Mass storage
- Network connectivity
- Study Information
- Image Information
- Show Findings /
Diagnosis
4- 4
Using MiroView™
Chapter 4
4.1 MiroView™ H/W Specifications
4.1.1
MiroView™ Server
Minimum Hardware Requirements
Recommended Hardware Requirements
4.1.2
OS: Windows Vista Business
CPU: > Core 2 Duo E6300
Memory: > DDR II 4GByte
Video Card: Windows Compatible
HDD: SATA 500GB
ODD: DVD+-RW
Monitor Resolution: 1024x768
OS: Windows Vista Business
CPU: > Core 2 Duo E6300
Memory: > DDR II 4GByte
Video Card: Windows Compatible
HDD: SATAII RAID 1TB
ODD: DVD+-RW
Monitor Resolution: 1680x1050
MiroView™ Client
Minimum Hardware Requirements
OS: Windows XP, Vista or Windows7
CPU: Pentium4 2 Ghz
Memory: 1GB
Video Card: Geforce 7600GT 128MB
HDD: SATA 160GB
ODD: DVD+-RW
Monitor Resolution: 1024x768
Sound Card / Mike / Speaker
Recommended Hardware Requirements
OS: Windows XP, Vista or Windows7
4-5
Chapter 4
4.1.3
CPU: > Core 2 Duo E6300
Memory: > DDR II 2GByte
Video Card: > Geforce 7600GT 128MB
HDD: SATA II 500 GB
ODD: DVD+-RW
Monitor Resolution: 1680x1050
Sound Card / Mike / Speaker
MiroView™ Operator
Minimum Hardware Requirements
4.1.4
OS: Windows XP, Vista or Windows7
CPU: Pentium4 2 Ghz
Memory: 1GB
Video Card: Windows Compatible
HDD: SATA 160GB
ODD: DVD+-RW
Monitor Resolution: 1024x768
Recommended Hardware Requirements
OS: Windows XP, Vista or Windows7
CPU: > Core 2 Duo E6300
Memory: 1GB
Video Card: Windows Compatible
HDD: SATA 160GB
ODD: DVD+-RW
Monitor Resolution: 1024x768
MiroView™ Viewer
Hardware Requirements
4- 6
Using MiroView™
OS: Windows XP, Vista or Windows7
CPU: Pentium4 2Ghz
Memory: 1GB
Video Card: Windows Compatible
HDD: SATA 160GB
ODD: DVD+-RW
Monitor Resolution: 1024x768
Using MiroView™
Chapter 4
CAUTION MiroView™ cannot be viewed on a monitor with a resolution
NOTE
under 1024x768.
The GUI is best viewed on a wide monitor of 19” or larger.
4-7
Chapter 4
4.2
Using MiroView™
Overview – MiroView™ Server
The MiroView™ Server software is intended to be used as a system
administrative managing tool. The MiroView™ Server manages file
systems and database systems.
When powering up the workstation, MiroView™ Server will start
automatically. If the following window appears, please set up the
configuration for the first run.

‚
ƒ
„
4- 8
Set the port number for the Network. If unknown, please leave this
field as ‘2000’. This field should be managed by your Network
Administrator in your hospital.
Set the password for ‘Administrator’ account. Additional accounts
can be made via Account Manager function, after logging on the
MiroView™ Operator as ‘Administrator’.
Confirm the password.
Type the Hospital Name.
Using MiroView™
Chapter 4
…
†
Type the Address that should appear on the Capsule Endoscope
Report.
Type the Telephone Number that should appear on the Capsule
Endoscope Report.
After setting up the Configuration Windows, MiroView™ Server
window above will appear. Click the
icon to hide the window.
4-9
Chapter 4
Using MiroView™
4.3 Overview - MiroView™ Operator
MiroView™ Operator software is intended to be used for administrative
purposes, including account and receiver management.
4.3.1
Start MiroView™ Operator
Double click the
icon to run the MiroView™ Operator.
When executed for the first time, the following window will appear.
Input “127.0.0.1” for the IP Address and “2000” for the Port.
Direct the “Local File Path” to the caching folder and choose the
4- 10
preferred Language settings and press
button to access
MiroView™ Operator.
After MiroView™ Operator has launched, the Log-in window will
appear.
Using MiroView™
Chapter 4
Input ‘Administrator’ for ID and password. Then press the
button.
CAUTION ID and password are encrypted. Do not forget the ID and
CAUTION
password.
Before MiroView™ Operator has launched, you must create
the password for the administrator account. When running
the MiroView™ Server for first time, the user must create
the password for the administrator account.
NOTE You can create new and edit existing accounts by using the
Account Management tool on MiroView™ Operator.
4-11
Chapter 4
Using MiroView™
The following subsections describe the main interfaces and functions
of the MiroView™ Operator.
4.3.2
List Mode
‚
†
‡
ƒ„…
○
○
○
○
○
○
○
4- 12
List Mode
Receiver Mode
Print Report
Recycle Bin
Export
Search
Show all
Opens List Mode
Opens Receiver Mode
Print out the selected Report
Open Recycle Bin Window
Export the selected Report
Search Cases and/or Reviews by keyword
Refresh and Show all the Cases and Review on
the List
Using MiroView™
4.3.3
Chapter 4
Receiver Mode
Screen enables administration and status display for upto four
 ‚ ƒ
receivers.
„
…
○
○
○
Upload
Input
Patient’s
Information
Initialization
○
Receiver Port
○
Detail View
Upload images in the receiver to the server
Input Patient’s Information to the selected
receiver
Delete all data from the receiver and/or
prepare the receiver for the next patient.
Shows the status of the connected receiver for
each of the four ports
Shows the patient’s information for the
selected receiver
4-13
Chapter 4
4.3.4
Receiver Initialization
Click the
4- 14
Using MiroView™
button to initialize the selected receiver.
Using MiroView™
4.3.5
Chapter 4
Inputting Patient Information
Click the
button to enter the patient information. After
completing the required fields, click the
button to save the
patient information onto the Receiver. The fields in the patient
information are editable and additional fields can be added. This can
be accessed via Tools à Preferences à Receiver à Set à Add /
Modify.
* indicates required fields.
4-15
Chapter 4
4.3.6
Using MiroView™
Data Upload
After the capsule endoscopy procedure, upload the data from the
Receiver to the MiroCam® system via MiroView™ Operator.
Click
the
button to upload the data from the Receiver.
After the image data in the MiroCam® Receiver has been
successfully uploaded, enter the List Mode and check if the new Case
has been created.
- Double click the
icon to run MiroView™ Client.
- Select the newly uploaded Case and enter the Review Mode.
- Play the case to check the uploaded image data.
CAUTION If you fail to upload the data from the Receiver,
NOTE
NOTE
4- 16
disconnect and reconnect the USB cable from the
workstation, then turnoff the MiroCam® Receiver
and turn it back on. Try uploading again. If the
problem persists, please contact IntroMedic.
If the user uploads a patient data which has been
uploaded before, an error message ‘Data has been
previously uploaded. Would you like to upload
again?’ will appear.
Upload progress will be displayed. The user can
stop the process while uploading by clicking the
button.
Using MiroView™
4.3.7
Chapter 4
User Account Management
MiroView™ Operator enables management of multiple users &
Groups. Users can be organized into Groups to readily control
access. The following screen can be accessed by Tools à Account
Manager.
4-17
Chapter 4
Using MiroView™
Add an account. Click
displayed below.
button to show the window as
ID: User ID
Password: Password
Name: User Name
Type: User type.
- Super User: can access all the reviews in the System
- User: can access all the reviews in the Group of the User’s
- Operator: can log in via MiroView™ Operator S/W only.
※ Administrator account can log in via both MiroView™ Client and
MiroView™ Operator.
Group: Set of users in the same Clinic or Laboratory.
4.4 Overview - MiroView™ Client
4.4.1
4- 18
Start MiroView™ Client
Double Click the
Enter the User ID and password and click the
button to run MiroView™ Client.
button.
Using MiroView™
4.4.2
Chapter 4
List Mode
List
 ‚ ƒ„
Š
11
○
12
○
…
†
‡
ˆ
‰
13
○
○
○
○
○
○
○
○
○
○
10
○
11
○
List Mode
Review Mode
Report Mode
Export Mode
Print Report
Add a Review
Delete Case
Delete Review
Recycle Bin
Search
Show all
12
○
13
○
Selection Bar
Detail View
Open List Mode
Open Receiver Mode
Open Report Mode
Open Export Mode
Print selected Report
Add a Review for the Selected Case
Delete selected Case
Delete selected Review
Open Recycle Bin
Search Cases and/or Reviews by key word
Refresh and Show all the Cases/Reviews on the
List
A rectangular area to show selected item
Show Detail Information for selected Case or
Review
4-19
Chapter 4
4.4.3
Using MiroView™
Review Mode
Select a case to review on the List Mode and click the
enter the Review Mode.
icon to
Capture Box Mode
 ‚ƒ „
28
○
25
○
26
○
27
○
6○
7○
8○
9○
10 ○
11 ○
12 ○
13 ○
14 ○
15 ○
16 ○
17 ○
18 ○
19 ○
20 ○
21 ○
22 ○
23 ○
24
5 ○
○
4- 20
○
○
○
○
○
List Mode
Review Mode
Report Mode
Export Mode
Positioning Window
Open List Mode
Open Review Mode
Open Report Mode
Open Export Mode
Current position of the capsule in 2D
○
Single View
Change to Single View
○
○
○
10
○
Dual View
Tri View
Range View
Normal View
Change to Dual View
Change to Quad View
Change to Range View
Shows all images taken by the
Capsule
Using MiroView™
11
○
Express View
12
○
SGIB
13
○
14
○
15
○
16
○
17
○
18
○
19
○
20
○
21
○
Previous Image
Previous Capture
Play Backward
Pause / Resume
Play Forward
Next Capture
Next Image
Capture
Landmark
22
○
Image Enhancement
23
○
Time Display
24
○
25
○
Zoom View
Comparison Window
26
○
Thumbnail Extension
27
○
Capture Box
Chapter 4
Actively removes images based upon
similarity; effectively reducing the
number of images for review. This
mode is recommended to review the
patient file.
Shows images that have high
possibility of bleeding and / or blood.
This mode may assist in finding areas
of suspected bleeding; however, it is
NOT 100% reliable, and should only
be used as an adjunctive tool to assist
in reviewing the images.
Go to Previous Image
Go to Previous Capture
Play Backward
Pause / Resume
Play Forward
Go to the Next Capture
Go to the Next Image
Image capture button.
Set landmarks for transition points in
the GI tract.
Alter images characteristics (ie. color,
saturation etc.) to assist in identifying
abnormalities.
Displays the time duration of the
capsule from procedure start.
Fit image to full screen
Displays the image selected from the
Image Atlas.
Extends the Capture Box to display all
captured images.
Toggle the Capture Box to Thumbnail
and Finding Summary Box
4-21
Chapter 4
Using MiroView™
Finding Summary Box
28
○
28
○
4- 22
Finding Summary Box
Toggle the Capture Box to Thumbnail
and Finding Summary Box Initially, a
captured image will be classified as a
generic ‘capture’. A user may classify
a finding through the reporting tool
Auto-Finding Checker, which will then
appear in the appropriate category in
the Finding Summary Box (if it is one
of the major categories).
Using MiroView™
Chapter 4
Mode Control
Zoom View
Click the
icon to change to Zoom View mode
NOTE Play Slide Control is available on the Zoom View
mode to set playing direction and speed.
NOTE Move the cursor away from the bottom of the
screen and the Play Control will appear.
4-23
Chapter 4
Using MiroView™
- Viewing Modes
Select one of the
icons for preferred Viewing
Mode.
Single View
Quad View
Dual View
Range View
NOTE Range View has been designed to assist in readily
finding transition points in the GI tract. The display
will show 9 images before and 9 images after the
current position. The 9 images are defaulted to 10
minutes apart, resulting in an overview of 90
minutes prior to, and 90 minutes after the current
position. The number of images displayed is set at
9, and is not configurable. The 90 minute duration
is configurable and can be adjusted by clicking and
dragging the mouse icon on the time boundary.
4- 24
Using MiroView™
Chapter 4
※ Map View
This view has been designed to
assist in findings by showing all
the images on the same page
like a wall paper.
You can move the cursor on the
designated image to see the
original image in detail.
Map View
The
icons will change to playing Mode, as detailed below.
Normal Mode
Express Mode
SGIB Mode
4-25
Chapter 4
Using MiroView™
Activated Windows
- Positioning Window
Displays the location of where the
capsule took the current image.
- Comparison Window
Displays the image selected from the
Image Atlas.
- Image Enhancement Window
Alter images characteristics (ie. color,
saturation etc.) to assist in identifying
abnormalities.
4- 26
Using MiroView™
4.4.4
Chapter 4
Report Mode
Select the desired review for the Case from the List Mode and click the
icon to move to the Report Mode.
Report Mode
‚ƒ „
…†
‡
ˆ
11
○
12
○
13
○
Š
‰
○
○
○
○
○
List Mode
Review Mode
Report Mode
Export Mode
Scale
○
Drawing Tools
○
Image
Enhancement
Open List Mode
Open Review Mode
Open Report Mode
Open Export Mode
Opens graduated scale for display on the
image
Enables users to include annotations for the
image.
Alter images characteristics (ie. color,
saturation etc.) to assist in identifying
abnormalities.
4-27
Chapter 4
○
Using MiroView™
GI Dictionary
Provides the frequently-used-words to search.
○
Text Comments
10
○
Audio Comment
11
○
12
○
13
○
Input Word
Add Word
Delete Word
Write comments for the Capture on the main
display and the report.
(Image Comments, Reason for Referral,
Procedure info & findings, Summary &
Recommendation)
Record voice commenst
(The user can record min 3 sec ~ max 300
sec for each Capture)
Input the selected word into the text editor.
Add the typed word into the Dictionary.
Delete selected word from the Dictionary.
NOTE Additional tabs in the report can be created or
modified via Tools
4- 28
-> Preferences -> Report
Using MiroView™
4.4.5
Chapter 4
Export Mode
‚ƒ „
…†
○
○
○
○
○
○
○
○
○
10
○
List Mode
Review Mode
Report Mode
Export Mode
Check
Captured
Image
Uncheck
Captured
Image
Print
Preview
Save as PDF
Export Review
11 ○
‡ ˆ‰ Š○
12 ○
13 ○
14 ○
15
Open List Mode
Open Review Mode
Open Report Mode
Open Export Mode
Select Captured image and add to the list to
print/export.
Deselect Captured image and remove from the
candidate list to print/export.
Print out the report for the Review.
Preview the report
Save the report as a PDF file.
Export Review data only without Video. Review
data is the own format of MiroView™, which
4-29
Chapter 4
11
○
Send to PACS
12
○
Export EXMIF
13
○
Export
14
○
Export
Segment
Export Entire
15
○
4- 30
Using MiroView™
contains Captured Images and Comments by
the user.
Send selected captured images to PACS system
via DICOM Sender
Export Captured Images as EXMIF
(eXchangeable Medical Information Format)
Export Captured Images as Image, Video, or
MiroVideo. MiroVideo is the own video format for
MiroView™.
Export segment as Video, MiroVideo
Export entire file as Video, MiroVideo
Using MiroView™
Chapter 4
4.5 Overview - MiroView™ Viewer
4.5.1
Start MiroView™ Viewer
Double Click the
button to run MiroView™ Viewer. Open a
Image File (EXMIF-Exchangeable Medical Image Format data or
JPEG) via ‘File -> Open’ function.
„

…
‚
ƒ
†
‡
○
○
○
○
Image Display
Title
Description
Study
Information
○
○
Image
Information
Findings
○
Diagnosis
Image Display Area (EXMIF or JPEG)
Title for the image in the Image Display
Description for the image in the Image Display
General Information (Software / Manufacturer /
Hospital Information), Patient Information
(Doctor, Patient Body Shape) and Study
Information (Doctor, Receiver, Capsule and
Procedure Information) for the image in the
Image Display
Creator Information and/or Finding Comments
for the image in the Image Display
Findings information the creator captured and
commented before for the image in the Image
Display.
Diagnosis information the creator captured and
commented on for the image in the Image
Display.
4-31
Chapter 4
Using MiroView™
4.6 Performing Capsule Endoscopy
4.6.1
4- 32
Initializing Receiver
Connect the Receiver to the workstation via USB port.
Run the MiroView™ Operator by double clicking the icon on the
desktop or from the Windows Start-up menu. Log in.
Enter the Receiver mode and select the Receiver port to initialize.
Using MiroView™
Chapter 4
Click the
Click ‘Yes’ to start the initializing process.
After the initializing process is complete, the following message will
appear.
icon. The following message will appear.
4-33
Chapter 4
Using MiroView™
Click ‘OK’ and the Patient Information window will appear. Input
the patient information for each field.
Click ‘Check Name’ button to input the patient name and then click
the ‘Check Doctor Name’ button to input the doctor name.
(The fields marked with * is required.)
Click
to save the Patient Information to the Receiver. The
Receiver is now ready for the procedure.
NOTE The fields in the patient information are editable,
and additional fields can be added. This can be
accessed via Tools à Preferences à Receiver
à Set à Add / Modify.
4- 34
Using MiroView™
4.6.2
Chapter 4
Upload Data (MiroView™ Operator)
Connect the Receiver to the workstation via USB port.
Run the MiroView™ 2.0 Operator by double clicking the icon on
the desktop or from the Windows Start-up menu. Log in.
After switching the Receiver on, enter the Receiver mode and
select the proper Receiver port to upload the patient file.
4-35
Chapter 4
Using MiroView™
Click the
After completing the Upload, the following message will appear.
4.6.3
button to start the Upload.
Review (MiroView™ Client)
Run MiroView™ Client by double clicking the icon on the desktop
or from the Windows Start-up menu. Log in.
*If you want to run the MiroView™ Client as Local Mode, click
‘Local’ button on the Log-in screen.
4- 36
Using MiroView™
Chapter 4
Select the Patient Video Data on the List Mode
- Select a patient video data to review from the List Mode and click
the
icon to enter the Review Mode.
- Check to see if another user is reviewing the patient file on the
Current User column in the List Mode.
- If the patient file is being reviewed by another user, a message will
appear.
4-37
Chapter 4
Using MiroView™
Review the Patient Video on the Review Mode
NOTE For efficient video playback the video is cached
locally in the server. During this buffering process,
the video may be reviewed.
– Click the ‘Range View’ icon to readily set landmarks.
4- 38
Using MiroView™
Chapter 4
- Use the Range View and Normal View to find all the landmarks.
NOTE Click the landmark icon and select landmark type:
Esophagus, Gastric, Duodenum, IleoCecal, and
Cecal.
- After marking the necessary landmarks, play the video via the
Express mode and capture abnormalities and / or suspected disease
pathologies in the small bowel.
4-39
Chapter 4
Using MiroView™
NOTE The user can press ‘Enter’ key to capture the
image.
- To identify abnormalities and/or disease pathology more easily, use
the Image Enhancement function to adjust preferred image settings.
Click the
4- 40
icon to open the Image Enhancement window.
Using MiroView™
Chapter 4
Composing the Report on the Report Mode
- After capturing images of suspected disease in the Review Mode
pathology, click the
icon to enter the Report Mode.
- Use the auto complete dictionary slide and choose available
disease pathology from the list.
- Completing the report:
1. Complete image comments for captured images (as required)
2. Complete the following tabs: Reason for referral; Procedure
Info & Findings; and Summary & Recommendations
3. After completing the report, enter the Export Mode to print out
the complete report and/or export MiroView™ 2.0 data.
4-41
Chapter 4
Using MiroView™
NOTE The GI Dictionary tab and findings tab allow the
user to adjust the findings and the level of severity.
The user can use the GUI easily.
CAUTION Do not detach and/or attach the Microphone
CAUTION
CAUTION
4- 42
from/to the workstation while recording the audio
comment.
Sound Card Driver must be installed prior to using
the Recording function.
Prior to recording the comments, close all the
applications using the Sound Card such as
music/video player.
Using MiroView™
Chapter 4
Print report, create file and export the Review on the Export
Mode.
Select the images to select and click
button to add the
selected captured images to the candidate list to export. (You
can remove the selected images from the candidate list using
the
button)
4-43
Chapter 4
Using MiroView™
Click the
button to use export function. A window will
appear like below.
Select the File Type to export and change the desired file
location on the Selected Folder and click the
A window will appear with a progress bar.
4- 44
button.
Using MiroView™
Chapter 4
- The user can use the
button for EXMIF, the
button
for Segment Export (Video / Miro Video) and the
button
for Export Case function.
NOTE Select the segments on the Timebar to export. If
no segment is selected, the
segments would be disabled.
button to export
NOTE MiroVideo
includes Reviews and selected
Segments so that the user can confirm the
contents and edit from ‘Open Case / Review file…’,
‘Import Case / Review file…’ main menu.
4-45
Chapter 4
Using MiroView™
Print Report and save the report as PDF on the Report Preview
- Click the
icon to print reports and/or click the
icon to
save the report as PDF.
- Show report preview on the screen.
- The user can print out the report and save the report to PDF file
in this screen.
- If the user selects the 6 images or 9 images per page mode and
tries to print out, the message ‘If you proceed with the current
Layout mode, image comments may be omitted and not printed.
Please select another Layout Mode to include all comments in the
report.’ will appear.
4- 46
Using MiroView™
4.6.4
Chapter 4
Image Atlas
Atlas
Reference images are searchable by Capsule Endoscopy
Structured Terminology (CEST), Endoscopy 2005; 37: 951 - 959
C Given Imaging Ltd.)
(February 16, 2002 ○
11
 ‚ ƒ †‡ˆ‰Š○
12
○
13
○
„
…
16
○
14
○
15
○
○
○
○
Atlas
My Atlas
Atlas + My Atlas
○
Import
Atlas
Images from file
Export
Atlas
Images to file(s)
Edit Information
○
○
○
Export
Atlas
Image(s) to E-
Default Atlas Images
Atlas Images configured by the user
Show Atlas Images and My Atlas Images at
once.
Import Atlas Images from file; BMP, JPEG,
GIF, EMF, WMF, TIFF and PNG file format.
Export Atlas Images to file; BMP, JPEG, GIF,
EMF, WMF, TIFF and PNG file format.
Edit the Information for the selected Atlas
Image.
Export Atlas selected Atlas Image(s) and
sends it / them to another doctor via E-mail.
4-47
Chapter 4
Using MiroView™
mail
○
Delete Atlas
Delete the selected Atlas Image(s)
Image(s)
○
10
○
11
○
12
○
13
○
14
○
15
○
Print Atlas
Image(s)
Save as PDF
Print the selected Atlas image(s)
Show/Hide
Marks
Search
Show / Hide Marks on the Atlas Image(s)
Comparison
Window
Browser
Tab(Findings /
Diagnosis)
Recent Images
Show the Comparison Window
Save the selected Atlas Image(s) as PDF
Search the Atlas Image
Area where to select the Category of the Atlas
Image to see.
Images that the user saw on the Comparison
Window
17
○
18
○
19
○
4- 48
Using MiroView™
17
○
18
○
19
○
Chapter 4
Image
Information
Findings /
Diagnosis
Atlas Thumbnail
Area(2)
Show the Information for the Atlas Image
Comparison
Window
Show the Current Image and Comparison
Image at once.
Show the Findings / Diagnosis Information
Search the Atlas Image
20
○
20
○
4-49
Chapter 4
Using MiroView™
Import Atlas Images from file(s)
MiroView™ allows the user to import image files for personal
purpose.
- Click the
to import.
4- 50
icon to open the ‘Open’ Browser to look for the files
Using MiroView™
Chapter 4
- Select the file to import and click ‘Open’
- Complete the ‘Title’, ‘Description’ and ‘Image Information’ fields and click
‘OK’.
4-51
Chapter 4
Using MiroView™
4.7 How to import MiroView™ 1.0 files
4.7.1
Preparing files for import
Run the MiroView™ 1.0
Export files by clicking ‘Export for MiroView Express’ function on
MiroView™ 1.0
Before using the Export to MiroView Express function, you must insert
DVD media to the DVD writer or connect the external hard disk or USB
flash memory to the workstation via USB port.
1.
Select a patient file from the list to export to MiroView Express.
2.
Execute ‘Export to MiroView Express…’ on the main menu
4- 52
Using MiroView™
3.
Chapter 4
If the form, ‘Save As’ appears like below, select the location to export and
fill in the ‘File name’ field and click ‘Save’.
4.
The window appears like below and if the function ends successfully you
will see the message, “Exporting has been completed.”
4-53
Chapter 4
4.7.2
Using MiroView™
Import MiroView 1.0 files
Run the MiroView™ 2.0 Operator or MiroView™ 2.0 Client.
Execute the ’Import Case / Review File… -> Import Case’ in the ‘List’
menu
4- 54
Using MiroView™
Chapter 4
Select MiroView™ 1.0 files from the file extension drop-down box and
look for the file to upgrade
Look for the File with extension ‘.MiroCam’ and click ‘Open’
4-55
Chapter 4
Using MiroView™
Task Manager will appear and will proceed with importation of the file.
If the Doctor name on the file is not registered on the MiroView™ 2.0
Server, ‘Doctor in charge’ registration process will start.
4- 56
Using MiroView™
Chapter 4
If the Reviewer name on the file is not registrered on the MiroView™
2.0 Server, ‘Reviewer’ registration process will start.
Complete necessary fields and click ‘OK’.
4-57
Chapter 4
Using MiroView™
Progress bar will appear.
Upgrading MiroView™ 1.0 file to MiroView™ 2.0 file will be completed.
4- 58
Using MiroView™ RTV
Chapter 5
5- 2
Using MiroView™ RTV
Using Wireless MiroView™ RTV
Chapter 5
5. USING MIROVIEW™ RTV
MiroView™ RTV, the application software for the MiroCam® System Realtime Viewer, consist of a data transmission module that directly receives
the image data from the MiroCam® Receiver and an output module for
image display.
5.1 Overview
MiroView™ RTV software can be installed on any mobile platform. Click
the corresponding icon on the desktop to launch the MiroView™ RTV.
5.1.1
Basic Screen Layout
 Name / ID / Gender / Age
‚ Start / Pause / Resume
ƒ Main Display
„ Time Display
 Patient
‚
ƒ
„
Information
Operation
Button
Main Display
Time Display
Display patient name, ID, gender and age
Change MiroView™ RTV operation status
between start, pause and resume.
Display captured image.
Indicates the MiroCam® capsule endoscope
procedure time.
5-3
Chapter 5
5.1.2
Using MiroView™ RTV
Basic Mobile PC Layout

‚
ƒ
USB Port for connect with MiroCam® Receiver
 USB Port
Connector for Mobile PC Charger
‚ DC-Jack
Power
Switch
Mobile PC Power on switch.
ƒ
WARNING Only recharge the mobile PC batteries when MiroCam®
Receiver does not connect to the mobile PC.
WARNING For safe use of mobile PC, please refer to mobile PC User
Manual.
5- 4
Using Wireless MiroView™ RTV
5.1.3
Chapter 5
Recommended Hardware Specification
Operating System : Windows XP Professional
CPU : A110 800Mhz
Memory : DDR II 1GByte(667MHz)
Display Adaptor : Windows Compatible
Hard Disk : Over 1GB
Monitor Resolution : 1024x600
Monitor Contrast : Windows Compatible
In compliance with IEC60950-1 or IEC60601-1
5-5
Chapter 5
Using MiroView™ RTV
5.2 Using MiroView™ RTV
5.2.1
Before Using MiroView™ RTV
The MiroView™ RTV software is pre-install on mobile PC
WARNING Do not use MiroView™ RTV software and mobile PC before
upgrading the MiroCam® Receiver.
WARNING Do not upgrade MiroCam® Receiver during the MiroCam®
capsule endoscopy procedure, it may result in loss if image
data.
Connect the data cable for the Real-time Viewer to the MiroCam®
Receiver.
NOTE The data cable for MiroView™ RTV has no cover for the
USB port on the MiroCam® Receiver.
Fallow the MiroCam® capsule endoscopy procedure.
NOTE For more information on the MiroCam® capsule endoscope
procedure, please refer to Chapter 3, Performing Capsule
Endoscopy.
5- 6
Using Wireless MiroView™ RTV
5.2.2
Chapter 5
Starting MiroView™ RTV
Switch on the mobile PC.
Click the
icon on the desktop to launch MiroView™ RTV.
Connect the small side of the USB cable to the MiroCam®
Receiver.
Connect the large side of the USB cable to the Mobile PC.
Click the
button to start image display
Click the
button to stop image display
Click the
button to restart image display
Click the
button on the top-right to close the MiroView™ RTV.
NOTE Start, Pause, and Resume use the same button. The
CAUTION
CAUTION
NOTE
function (Start, Pause or Resume) changes based upon the
status of MiroView™ RTV software.
MiroView™ RTV is not software for to be used for
diagnostic purposes. Use the MiroView™ software for
viewing the patient images for diagnostic purposes.
Do not disconnect the MiroCam® Receiver while the RTV is
in use. If the MiroCam® Receiver is disconnected during
use, the software may need to be restarted.
If an error message appears while using MiroView™ RTV,
reconnect the USB cable between MiroCam® Receiver and
Mobile PC
5-7
Chapter 5
5.2.3
5- 8
Using MiroView™ RTV
After Using MiroView™ RTV
Disconnect USB cable from MiroCam® Receiver and mobile PC.
Continue MiroCam® capsule endoscope procedure.
6
Using Wireless MiroView™ RTV
Chapter 6
5- 2
Using Wireless MiroView™ RTV
Using Wireless MiroView™ RTV
Chapter 5
6. USING WIRELESS MIROVIEW™ RTV
Wireless MiroView™ RTV, the application software for the MiroCam®
System Real-time Viewer, consist of a data transmission module that
directly receives the image data from the MiroCam® Receiver and an
output module for image display. Wireless MiroView™ RTV receive image
data via Wi-Fi channel.
6.1 Overview
Wireless MiroView™ RTV software can be installed on I-OS 3 or I-OS 4
running on I-Pad / I-Phone / I-Pod Touch. Click the corresponding icon on
the desktop to launch the Wireless MiroView™ RTV.
6.1.1
Basic Screen Layout – I-Phone / I-Pod Touch
 ID / Name / Gender / Age
② Receiver Scan
③ Main Display
④ Time Display
5-3
Chapter 6
Using Wireless MiroView™ RTV
 Patient
‚
Information
Receiver
Scan Button
ƒ Main Display
„ Time Display
6.1.2
Display patient name, ID, gender and age
Show the available Receiver Access Points so
that the user can choose to see the patient
image.
Display captured image.
Indicates the MiroCam® capsule endoscope
procedure time.
Basic Screen Layout – I-Pad
② Receiver Scan
 ID / Name / Gender / Age
③ Main Display
④ Time Display
NOTE If turning the I-Pad upright as Portrait View, Receiver List
will disappear for the Main Display to be enlarged.
5- 4
Using Wireless MiroView™ RTV
 Patient
‚
Information
Receiver
Scan Button
ƒ Main Display
„ Time Display
6.1.3
Chapter 5
Display patient name, ID, gender and age
Show the available Receiver Access Points so
that the user can choose to see the patient
image.
Display captured image.
Indicates the MiroCam® capsule endoscope
procedure time.
Recommended Hardware Platform
I-Phone 3G, 3GS, 4G
I-Pod Touch 3G
I-Pad
5-5
Chapter 6
Using Wireless MiroView™ RTV
6.2 Using Wireless MiroView™ RTV
6.2.1
Network configuration for Wireless MiroView™ RTV
The Wireless MiroView™ RTV software is pre-installed on I-OS 3 /
I-OS 4 running on I-Phone, I-Pod Touch or I-Pad.
NOTE When the Wireless MiroView RTV run first, network
configuration for I-Phone and I-Pad is required.
Fallow the MiroCam® capsule endoscopy procedure.
Turn on the Wi-Fi switch on the MiroCam® Receiver System
during the Capsule Procedure.
NOTE For more information on the MiroCam® capsule endoscope
procedure, please refer to Chapter 3, Performing Capsule
Endoscopy.
5- 6
Using Wireless MiroView™ RTV
Chapter 5
Click the
Click the
button on the right-top to show the available
MiroCam® Receiver Access Points
icon on the desktop to launch MiroView™ RTV.
5-7
Chapter 6
5- 8
Using Wireless MiroView™ RTV
If no available Receiver® Access Points are shown on the list, the
image will appear like below. Please make sure that the WifiSwtich on the Receiver is turned on.
If the MiroCam® Receiver Access Points are shown on the list.
Click the desirable AP (Access Point) to show the patient’s image.
Using Wireless MiroView™ RTV
Chapter 5
At the first time to connect to the AP, IP setting is required as below
steps:
l Step 1. Press the Home Button on the I-Phone/I-Pad/I-Pod touch
to close the Wireless MiroView™ RTV Software.
l Step 2. Run the Settings for the I-OS.
5-9
Chapter 6
Using Wireless MiroView™ RTV
l Step3. Set the IP for the desirable AP. (Setup as Static; IP
Address : 192.168.3.200, Subnet Mask: 255.255.255.0)
5- 10
Using Wireless MiroView™ RTV
Chapter 5
After completing the IP setting, close the setting window by clicking
the home button on the I-Phone/I-Pad/I-Pod touch and go back to
the desktop.
5-11
Chapter 6
6.2.2
Using Wireless MiroView™ RTV
Running MiroView™ RTV
Fallow the MiroCam® capsule endoscopy procedure.
Turn on the Wi-Fi switch on the MiroCam® Receiver System
during the Capsule Procedure.
NOTE For more information on the MiroCam® capsule endoscope
procedure, please refer to Chapter 3, Performing Capsule
Endoscopy.
5- 12
Using Wireless MiroView™ RTV
Chapter 5
Click the
RTV.
The Splash window will appear for a while and will disappear.
icon on the desktop to launch Wireless MiroView™
5-13
Chapter 6
Using Wireless MiroView™ RTV
After the splash window disappears, the real time play will be
started automatically. (The number of receiver is one).
※
5- 14
If there are two or more Receiver AP is available, the
Receiver AP List window will be shown. Choose one to
continue as below:
After reviewing the real time play is completed, click the home
button to close.
Using Wireless MiroView™ RTV
Chapter 5
To terminate the Software completely, double click the home button.
The menu will pop up like below.
Press the Wireless MiroView RTV icon for a while. The
will appear.
mark
5-15
Chapter 6
Using Wireless MiroView™ RTV
Click the
icon, then the Wireless MiroView RTV will be
terminated completely.
CAUTION Wireless MiroView™ RTV is not to be used for diagnostic
purposes. Use the MiroView™ software for viewing the
patient images for diagnostic purposes.
6.2.3
After Using Wireless MiroView™ RTV
5- 16
Turn off the Wi-Fi switch on the MiroCam® receiver system.
Continue MiroCam® capsule endoscope procedure.
Appendix
Case Form Report
A- 2
Case Form Report
Trial ID :
Version No. : 1.0 : 30/07/2007
CASE REPORT FORM
Subject No.:
Principal
Investigator
Subject Initials :
Center No.:
Center Name
Address
Telephone No.
Fax No.
E-mail
CONFIDENTIAL
A-3
Case Form Report
Trial ID :
Version No. : 1.0 :
30/07/2007
Screening
Subject No.:
Subject Initials :
Center No.:
Date of Informed consent signed
Inclusion Criteria
Yes
No
N/A
1. Informed consent form voluntarily signed
2. Male / Female subject of age 19 years~70 years.
If there is one or more mark of ‘No’, you shall be contradicted for this clinical test.
CONFIDENTIAL
A- 4
Case Form Report
Trial ID :
Version No. : 1.0 : 30/07/2007
Screening
Subject No.:
Subject Initials :
Center No.:
Date of visit :
Exclusion Criteria
Yes
1.
2.
3.
4.
5.
No
Do you have a gastrointestinal disorder (suspected
malignantlesions or gastrointestinal obstructive disorders,
perforation, stenosis or fistula)?
Do you have a cardiovascular disorder (dysrhythemia, trouble
with cardiac conduction system, hypertension(high blood
pressure) or ischemic heart disease)?
Have you been diagnosed of cardiac insufficiency, angina
pectoris or cardiac arrest (heart attack) in recent 6 months?
Are you with (or implanted) medical devices such as cardiac
pacemaker or defibrillator?
Do you have a swallowing disorder?
6. Do you have delayed gastric emptying or serious gastric
disorder?
7. Are you a pregnant or nursing woman, or a woman of child
bearing potential?
8. Are you an infant or epileptic? Are you easily affected by
electronic waves?
9. Do you have several small bowel diverticulums ?
10.
Did you fail to obtain a voluntary agreement?
11.
Are you judged unqualified for this test by doctors or nurses?
If there is one or more mark of ‘Yes’, you shall be contradicted for this clinical test.
CONFIDENTIAL
A-5
N/A
Case Form Report
A- 6
EC Representative
SeDa S.p.A
20090 Trezzano sul Naviglio(MI),
Via Toistoi, 7 Italy
Key Contact: Roberta Cimolato
Office: +39-02-484241
Mobile: +39-02-48424290
Email: roberta.cimolato@sedaitaly.it
Disposal of Old
Electrical &
Electronic
Equipment
Applicable in the
European Union
and other
European
countries with
separate collection
systems
IntroMedic Co.,Ltd.
Suite 1104, E&C Venture Dream Tower 6-Cha
197-28 Guro-Dong, Guro-Gu, Seoul, KOREA 152-719
Tel : +82-2-801-9300
Fax : +82-2-801-9330
http://www.intromedic.com
e-mail : help@intromedic.com
0297


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
Linearized                      : No
Page Count                      : 144
Tagged PDF                      : No
Language                        : ko-KR
Page Layout                     : SinglePage
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
PDF Version                     : 1.4
Producer                        : Haansoft PDF 1.3.0.407
Creator Tool                    : Haansoft PDF 1.3.0.407
Create Date                     : 2011:05:17 13:00:42+09:00
Modify Date                     : 2011:05:17 13:00:42+09:00
Metadata Date                   : 2011:05:17 13:00:42+09:00
Format                          : application/pdf
Creator                         : Ballista
Title                           : Microsoft Word - User Manual_English Edition for MR1100_20110511.doc
Date                            : 2011:05:17 13:00:42+09:00
Document ID                     : 04A944DF-A018-4084-842F-77681324ABE6