Invixium Access MRGCR IXM MERGE CR User Manual

Invixium Access Inc. IXM MERGE CR Users Manual

Users Manual

Download: Invixium Access MRGCR IXM MERGE CR User Manual
Mirror Download [FCC.gov]Invixium Access MRGCR IXM MERGE CR User Manual
Document ID3796290
Application IDmKlemtGMtYD+xuGEiV5mMw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.97kB (349677 bits)
Date Submitted2018-03-26 00:00:00
Date Available2018-03-27 00:00:00
Creation Date2018-03-07 10:29:07
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2018-03-07 10:29:07
Document TitleUsers Manual
Document CreatorMicrosoft® Word 2010
Document Author: Abhinav Gupta

IXM MERGE CR
Internal User Guide
Rev. 0.5
Contents
Internal User Guide............................................................................................................... 1
1.
Introduction ................................................................................................................... 3
2.
Basic Operation .............................................................................................................. 5
3.
Pin out and Signal Description ....................................................................................... 6
FCC & IC Information for Users ...................................................................................... 7
4.1.
FCC ID: S38-MRGCR................................................................................................. 7
4.2.
IC: 10981A-MRGCR.................................................................................................. 8
5.
Labeling Requirements................................................................................................... 8
6.
OEM Labeling Requirements ........................................................................................... 9
1. Introduction
IXM MERGE CR, M/N IXM006 is ISO/IEC14443A RFID module.
It is designed and manufactured by Invixium Access Inc., to provide not only the
RFID reader, but also with added LCD and fingerprint sensor, fully fledged
fingerprint biometric reader (IXM MERGE FP22, M/N IXM026).
Any other use of the IXM MERGE CR makes all certifications involved null and void,
and is strictly prohibited. IXM MERGE CR is intended for products manufactured by
Invixium Access Inc. and it is not available to third parties.
This User Guide is Internal, targeting crew in Production, QA, and Technical Support
of the Invixium Access Inc.
Block Diagram of IXM MERGE CR
Ethernet
RS-485
GPIO
Wiegand
12-24 VDC
PoE
CPU
Audio
Codec
Speaker
Integral RFID:
NXP 13.56 MHz
2. Basic Operation
IXM MERGE CR is ISO/IEC14443A RFID Card reader that can send card reading
results to an Access Control Panel via Wiegand interface, to a Time & Attendance
application via Ethernet, or can control the door entry by itself if so configured and
wired.
In Time and Attendance (T&A) application, device either sends the result to the
application via Ethernet, or stores it into transaction log locally, and T&A application
fetches it from the log.
If configured and wired as per the Installation Guide, as a Single Door Controller,
device can control door as an Access Control Panel would do.
The module is configured using Invixium’s Web-based application IXM WEB. IXM
WEB communicates with the module through Ethernet, RS-485, or through internal
USB service port.
For the testing in Production, the IXM Tester tool, configures and tests IXM MERGE
CR module automatically.
3. Pin out and Signal Description
Pin
Number
10
11
12
13
14
15
16
17
18
19
20
Signal Name in
Installation Guide
VIN+
RS485-(A)
VINRS485+(B)
EGND
DAC_OUT
DGND
SPO_1
WDATA_OUT1
WDATA_OUT0
DAC_IN2
DAC_IN1
DAC_iN3
WDATA_IN0
TAMPER
WDATA_IN1
RLY_NO
RLY_COM
SGND
RLY_NC
Description
Vin+
RS485 DVinRS485 D+
Earth GND
Single door controller output
DGND
General Purpose Output
Wiegand Output 1
Wiegand Output 0
Single door controller input 2
Single Door controller input 1
Single door control input 3
Wiegand Input 0
Tamper Alarm output
Wiegand Input 1
Relay, Normally Open Contact
Relay, Common Contact
RS-485 GND
Relay, Normally Closed Contact
Devices also have RJ-45 Ethernet connector, as well as DC input bullet connector.
The temperature range of IXM MERGE CR:
-20 to 600 C for MERGE CR
Power Requirements:
12 to 24 VDC, <4W
PoE (alternative A or B)
PoE +
4 FCC & IC Information for Users
4.1.
FCC ID: S38-MRGCR
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
This device and its antenna must not be co-located with any other transmitters except in accordance
with FCC multi-transmitter product certification procedures.
Changes or modifications made to this equipment not expressly approved by Invixium Access Inc.
could void the user’s authority to operate the equipment.
4.2.
IC: 10981A-MRGCR
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the
following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts
de licence. L’exploitation est autorisée aux deux conditions suivantes :
1) l’appareil ne doit pas produire de brouillage;
2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
This device and its antenna must not be co-located with any other transmitters except in accordance
with IC multi-transmitter product certification procedures.
Cet appareil et son antenne (s) ne doit pas être co-localisés ou fonctionnement en association avec
une autre antenne ou transmetteur.
5. Labeling Requirements
The device label will be affixed on the back of the LED portion of the PCBA.
The label content:
IXM MERGE CR
FCC ID: S38-MRGCR
IC: 10981A-MRGCR
HVIN M1_N22
6. OEM Labeling Requirements
WARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC
labeling requirements are met. This includes a clearly visible label on the outside of
the final product enclosure that displays the contents shown in the figure below.
Required FCC Label for OEM products containing this Module, including the
packaging:
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference and
(2) this device must accept any interference received, including interferences that
may cause undesired operation.
Contains FCC ID: S38-MRGCR
Contains IC: 10891A-MRGCR
IMPORTANT: OEMs must test final product to comply with unintentional radiators
(FCC section 15.107 & 15.109) before declaring compliance of their final product to
Part 15 of the FCC Rules.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 9
Language                        : en-CA
Tagged PDF                      : Yes
Author                          : Abhinav Gupta
Creator                         : Microsoft® Word 2010
Create Date                     : 2018:03:07 10:29:07-05:00
Modify Date                     : 2018:03:07 10:29:07-05:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S38-MRGCR

Navigation menu