Itron 100GDLC AMR transceiver device for utility meters User Manual 100G Datalogging Installation Guide Direct Mount
Itron, Inc. AMR transceiver device for utility meters 100G Datalogging Installation Guide Direct Mount
Itron >
Contents
- 1. Users Manual Part 1
- 2. Users Manual Part 2
- 3. Users Manual Part 3
Users Manual Part 1
Natural Gas Solutions 100G Datalogging Installation Guide Direct Mount Identification 100G Datalogging Installation Guide - Direct Mount 03/6/2009 TDC-0823-000 Endpoint Part Numbers: 100G Endpoint: ERG-5000-001, ERG-5000-002, ERG-5000-003, ERG-5000-004, ERG-5000-005, ERG-5000-006, ERG-5000-007, ERG-5000-008 100G Datalogging Endpoint: ERG-5002-001, ERG-5002-002, ERG-5002-003, ERG-5002-004, ERG-5002-005, ERG-5002-006, ERG-5002-007, ERG-5002-008 Copyright © 2009 Itron, Inc. All rights reserved. Applicable Patents U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700 Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118 Compliance Statement This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions: • This device may not cause harmful interference. • This device must accept any interference that may cause undesirable operation. This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels. Compliance Statement This equipment has been tested and found to comply with the limits, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following conditions: • This device may not cause interference. • This device must accept any interference that may cause undesired operation of the device. Compliance Statement This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Trademark Notice Itron and Endpoint-Link are registered trademarks of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Suggestions If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com If you have questions or comments about the software or hardware product, contact Itron Technical Support: Contact • • • • Mail: Itron, Inc. Attention: Customer Care, 2111 N Molter Road, Liberty Lake, WA 99019 Internet: www.itron.com E-mail: support@itron.com Phone: 1 800 635 8725 WARNING! Follow these procedures to avoid injury to yourself or others: •The lithium battery may cause a fire or chemical burn if it is not disposed of properly. •Do not recharge, disassemble, heat above 100° Celsius (212° Fahrenheit), or incinerate the lithium battery. •Keep the lithium battery away from children. •Replace the lithium battery only with batteries meeting Itron specifications. Any other battery may cause a fire or explosion. WARNING! Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted. WARNING! To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. WARNING! Substitution of components may impair intrinsic safety. 100G Datalogging Installation Guide - Direct Mount ii Transportation Classification The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G Datalogging Endpoint is considered an operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation. Modifications and Repairs To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's authority to operate the equipment. Meter Installation/Removal In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron. 100G Datalogging Installation Guide - Direct Mount iii Document Conventions The following documentation conventions are used: CAUTION! This type of note warns the user that failure to heed the information in the note could result in loss of data. Be sure to carefully read a CAUTION note and heed the advice/instructions. WARNING! This type of note is used to warn of potential physical harm to the user or hardware. It is critical that you pay strict attention to WARNING notes, read the information carefully, and heed the advice, instructions. This type of note provides the user with extra hints/tips to make a task easier to perform or a concept easier to understand. This type of note supplies generic information to the user. The information could be ignored and the user could still continue with a task without suffering any adverse consequences. 100G Datalogging Installation Guide - Direct Mount iv Contents Chapter 1 100G Datalogging Gas Endpoint................................................................ 1 Transmission Modes ........................................................................................................................... 1 Specifications ...................................................................................................................................... 2 Related Documents .................................................................................................................. 2 Meter Compatibility List ....................................................................................................................... 2 Installation Prerequisites ..................................................................................................................... 8 Chapter 2 Elster American Meter Installation........................................................... 11 Programming the 100G Datalogging Gas Endpoint Assembly .........................................................16 Attaching the 100G Datalogging Gas Endpoint Assembly to the Elster American Meter .................18 Chapter 3 Sensus/Rockwell Meter Installation......................................................... 21 Programming the 100G Datalogging Gas Endpoint Assembly .........................................................25 Attaching the 100G Datalogging Gas Endpoint Assembly to the Sensus Meter ..............................27 Chapter 4 Itron/Actaris Meter Installation ................................................................. 31 Programming the 100G Datalogging Gas Endpoint Assembly .........................................................34 Attaching the 100G Datalogging Gas Endpoint Assembly to the Itron/Actaris Meter .......................36 Attaching the 100G Datalogging Gas Endpoint Assembly to Flat-faced Itron/Actaris Meters 39 Securing Brass Meter Tags to Flat-faced Meters ...................................................................43 Chapter 5 National/Lancaster Meter Installation ...................................................... 47 Programming the 100G Datalogging Gas Endpoint Assembly .........................................................53 Attaching the 100G Datalogging Gas Endpoint Assembly to the National/Lancaster Meter ............55 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation ........ 57 Removing the Index/ Index Assembly from the Meter ......................................................................58 Programming the 100G Datalogging Commercial Gas Endpoint .....................................................60 Installing the 100G Datalogging Commercial Gas Endpoint on an Itron/Actaris Commercial Meter 67 Chapter 7 Sensus/Rockwell Commercial Meter Installation ................................... 73 Removing the Index/ Index Assembly from the Meter ......................................................................73 Programming the 100G Datalogging Gas Endpoint ..........................................................................74 Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commercial Diaphragm Meter ...............................................................................................................................76 100G Datalogging Installation Guide - Direct Mount Contents Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation ......................... 81 Installation Prerequisites .........................................................................................................81 Installation Examples ..............................................................................................................82 Programming the 100G Datalogging Gas Endpoint Assembly .........................................................83 B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive Programming Information ..................................................................................................................85 B3, LMMA and S3A CTR/TC Meter Drive Rates: Residential Direct Drive Programming* ...87 Installing the Residential 100G Datalogging Gas Endpoint Assembly to the Dresser ROOTS Rotary Meter ........................................................................................................................89 Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter ...90 Programming the 100G Datalogging Commercial Gas Endpoint Assembly ..........................91 B3, LMMA, and S3A CD/TD Dresser ROOTS Series Meter Drive Rates ..............................93 To Attach the 100G Datalogging Commercial Gas Endpoint to the Meter .............................95 Completed Installation Examples............................................................................................97 vi 100G Datalogging Installation Guide - Direct Mount CHAPTER 1 100G Datalogging Gas Endpoint Itron 100G Datalogging Gas Endpoints are radio-frequency (RF) devices designed to transmit meter data to an RF meter reading device within transmission distance of the endpoint. 100G Datalogging Gas Endpoints have the same increased output power as the first generation 100G Gas Endpoints for greater RF transmission distance. The 100G directmount endpoint reads and transmits a Standard Consumption Message (SCM) with magnetic-tamper and tilt-tamper data. The Itron 100G Datalogging direct-mount endpoint adds functionality by storing up to 40 days of hourly data. This installation guide provides step-by-step instructions for installing the 100G Gas Endpoint and the 100G Datalogging Gas Endpoint on a wide variety of meters. This installation guide refers to both 100G endpoint versions as the 100G Datalogging Endpoint. Mechanical installation procedures are identical for both modules. 100G Datalogging Gas Endpoint compatible meters are listed in the Meter Compatibility List. Transmission Modes The 100G Datalogging Gas Endpoint transmits in one of three modes: • Fixed Network Mode In this mode, a 100G Datalogging Gas Endpoint transmits a high-powered RF message every 60 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life is 20 years. • Mobile and Handheld Mode In this mode, a 100G Datalogging Gas Endpoint transmits a medium-powered RF message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is 20 years. • (Optional) Hard to Read Mobile and Handheld Mode In this mode, a 100G Datalogging Gas Endpoint transmits a high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode should only be used for exceptionally hard-to-read applications (such as meters installed on roof tops or in sub-basements). An FCC license is not required to read 100G Datalogging Gas Endpoint. 100G Datalogging Installation Guide - Direct Mount Chapter 1 100G Datalogging Gas Endpoint Specifications Functional Specifications Description Power Source 100G 100G Datalogging Tamper Detection Two "A" cell lithium batteries One "A" cell lithium battery FCC Compliance Part 15 certified Industry Canada Compliance RSS-210 certified Intrinsically Safe per UL Class I, Division 1, Groups C and D Product Identification Numeric and barcoded endpoint type and serial number Construction Materials Gray polycarbonate housing and back plate with encapsulated electronics Operational Specifications Description Operating Temperatures -40° to 158° F (-40° to +70° C) Operating Humidity 5 to 95 percent relative humidity Program Frequency 908 MHz Transmit Frequency Spread spectrum 908 to 924 MHz ISM band Data Integrity Verified in every data message Tilt tamper and magnetic tamper Related Documents Document Title Document Part Number Gas Endpoint Meter Compatibility List PUB-0117-002 Gas Endpoint Ordering Guide PUB-0117-001 100G Datalogging Specification Sheet Publication 100941SP-01 Endpoint Link® Programming Guide TDC-0744 Meter Compatibility List The Meter Compatibility table lists meters compatible with the 100G Datalogging Gas Endpoint. Due to continuous research, product improvements, and enhancements, Itron reserves the right to change this list without notice. Note On rare occasions the location of endpoint-to-meter mounting holes on older diaphragm gas meters might not match up with the mounting holes on the 100G Datalogging Gas Endpoint. This can prevent the 100G Datalogging Gas Endpoint from properly mounting to the meter. 100G Datalogging Installation Guide - Direct Mount Meter Compatibility List Mfg. 100G Series Meter Compatibility List Model Description Class Comments Endpoint Type Endpoint Part No. Elster American/ Canadian W75AL Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AL-175 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AT-175 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian ALC-175 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AT-210 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AL-225 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AL-250 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AR-250 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AC-250 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AM-250 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AL-310 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AL-350 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AT-350 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AL-425 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian AC-630 Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian 5B 225 Aluminum case Residential 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian 35B Iron case Commercial 100G ERG-5000-007 Elster American/ Canadian 60B Iron case Commercial 100G ERG-5000-007 Elster American/ Canadian 80B Iron case Commercial 100G ERG-5000-007 Elster American/ Canadian 250B Iron case Commercial 100G ERG-5000-007 Elster American/ Canadian 500B Iron case Commercial 100G ERG-5000-007 Elster American/ Canadian AL800 100G ERG-5000-007 Canada only Commercial 100G Datalogging Installation Guide - Direct Mount Must have front reading index. Aluminum case meters only Chapter 1 100G Datalogging Gas Endpoint Mfg. Model Elster American/ Canadian Description Class Comments Endpoint Type Endpoint Part No. AL1000 Commercial Aluminum case meters only 100G ERG-5000-007 Elster American/ Canadian AL1400 Commercial Aluminum case meters only 100G ERG-5000-007 Elster American/ Canadian AL2300 Commercial Aluminum case meters only 100G ERG-5000-007 Elster American/ Canadian AL3000 Commercial Aluminum case meters only 100G ERG-5000-007 Elster American/ Canadian AL5000 Commercial Aluminum case meters only 100G ERG-5000-007 R-175 11-tooth Residential R-200 11-tooth Residential RT-200 11-tooth Residential RC-225 11-tooth (Canada only) Residential RT-230 11-tooth Residential R-275 11-tooth Residential RT-275 11-tooth Residential R-315 11-tooth Residential 250 11-tooth Residential Sensus/Invensys/ Equimeter/Rockwell 310 11-tooth Sensus/Invensys/ Equimeter/Rockwell S-110 Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-002 ERG-5002-002 100G 100G Datalogging ERG-5000-002 ERG-5002-002 100G 100G Datalogging ERG-5000-002 ERG-5002-002 100G 100G Datalogging ERG-5000-002 ERG-5002-002 100G 100G Datalogging ERG-5000-002 ERG-5002-002 100G 100G Datalogging ERG-5000-002 ERG-5002-002 100G 100G Datalogging ERG-5000-002 ERG-5002-002 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-002 ERG-5002-002 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-002 ERG-5002-002 Residential 100G 100G Datalogging ERG-5000-002 ERG-5002-002 11-tooth Residential 100G 100G Datalogging ERG-5000-002 ERG-5002-002 S-200 11-tooth Residential 100G 100G Datalogging ERG-5000-002 ERG-5002-002 175-S 18-tooth Residential 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-004 ERG-5002-004 RT-100 18-tooth Residential 24- and 30-tooth gears are not compatible 100G 100G Datalogging ERG-5000-004 ERG-5002-004 S-190 18-tooth Residential 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-004 ERG-5002-004 24- and 30-tooth gears are not compatible. 100G Datalogging Installation Guide - Direct Mount Meter Compatibility List Mfg. Model Description Class Sensus/Invensys/ Equimeter/Rockwell S-120 11-tooth Sensus/Invensys/ Equimeter/Rockwell T-120 Sensus/Invensys/ Equimeter/Rockwell Endpoint Type Endpoint Part No. Residential 100G 100G Datalogging ERG-5000-002 ERG-5002-002 11-tooth Residential 100G 100G Datalogging ERG-5000-002 ERG-5002-002 T-110 11-tooth Residential 100G 100G Datalogging ERG-5000-002 ERG-5002-002 R-415 18-tooth Residential 100G 100G Datalogging ERG-5000-004 ERG-5002-004 100G 100G Datalogging ERG-5000-004 ERG-5002-004 100G 100G Datalogging ERG-5000-003 ERG-5002-003 100G 100G Datalogging ERG-5000-003 ERG-5002-003 Sensus/Invensys/ Equimeter/Rockwell RT-360 18-tooth Residential Sensus/Invensys/ Equimeter/Rockwell MR8 (R-275 Metric) 16-tooth Residential Sensus/Invensys/ Equimeter/Rockwell MR12 (R-415 Metric) 16-tooth Residential Sensus/Invensys/ Equimeter/Rockwell Comments Older meters may have endpoint-to-meter mounting hole variations that can make them incompatible. Sensus/Invensys/ Equimeter/Rockwell 750 Commercial 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 1000 Commercial 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 1600 Commercial 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 3000 Commercial 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 5000 Commercial 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 10000 Commercial 100G ERG-5000-008 National/ Lancaster 175 Residential Actaris/Schlumberger/ Sprague direct-read (odometer) indexes cannot be used. 100G ERG-5000-006 National/ Lancaster U175 UL175 Residential Actaris/Schlumberger/ Sprague direct-read (odometer) indexes cannot be used. 100G ERG-5000-006 National/ Lancaster 250 Residential Actaris/Schlumberger/ Sprague direct-read (odometer) indexes cannot be used. 100G ERG-5000-006 Itron/Actaris/ Schlumberger/ Sprague 175 Residential Index boxes with 3 mounting holes 100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 175 WC Index boxes with 3 mounting holes 100G ERG-5000-005 3-hole index box 3-hole index box Residential 100G Datalogging Installation Guide - Direct Mount Vertical index only Vertical index only Vertical index only Chapter 1 100G Datalogging Gas Endpoint Mfg. Model Description Class Comments Itron/Actaris/ Schlumberger/ Sprague 175 Combination 3-hole index box Residential Index boxes with 3 mounting holes Itron/Actaris/ Schlumberger/ Sprague 210 Itron/Actaris/ Schlumberger/ Sprague 240 Itron/Actaris/ Schlumberger/ Sprague 240 Combination Itron/Actaris/ Schlumberger/ Sprague 240 Itron/Actaris/ Schlumberger/ Sprague 240 1-hole cover flat face Residential Itron/Actaris/ Schlumberger/ Sprague 240 2-hole cover Residential Itron/Actaris/ Schlumberger/ Sprague 250 Itron/Actaris/ Schlumberger/ Sprague 250 WC Itron/Actaris/ Schlumberger/ Sprague 250 Combination Integrated regulator Residential Itron/Actaris/ Schlumberger/ Sprague 1A Flat face Residential Itron/Actaris/ Schlumberger/ Sprague METRIS 250 Itron/Actaris/ Schlumberger/ Sprague Integrated regulator Endpoint Part No. 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 + CFG-0015-001 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 + Residential Canadian Version of 250 Residential Integrated regulator Residential Residential Requires Itron 1A Adapter P/N CFG-0015-001 Kit Residential Residential Includes 3-dial, 2cf indexes. 3-hole index box Slant-faced Residential 305 Combination Integrated regulator Residential Itron/Actaris/ Schlumberger/ Sprague 400 Slant-faced Residential Itron/Actaris/ Schlumberger/ Sprague 400A Itron/Actaris/ Schlumberger/ Sprague 675A Top-mount index Itron/Actaris/ Schlumberger/ Sprague 800A Top-mount index Endpoint Type Slant-faced Requires Itron 1A adapter kit, CFG-0015-001 Index boxes with 3 mounting holes CFG-0015-001 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 Commercial 100G Requires Itron/Actaris adapter p/n 80005901-001; purchase from Itron/Actaris ERG-5000-007 Commercial 100G Requires Itron/Actaris adapter p/n 80005901-001; purchase from Itron/Actaris ERG-5000-007 Residential 100G Datalogging Installation Guide - Direct Mount Meter Compatibility List Mfg. Model Description Class Comments Itron/Actaris/ Schlumberger/ Sprague 1000A Top-mount index Commercial 100G Requires Itron/Actaris adapter p/n 80005901-001; purchase from Itron/Actaris ERG-5000-007 EMCO #2 ½ Commercial 100G ERG-5000-008 EMCO #3 Commercial 100G ERG-5000-008 EMCO #4 Commercial 100G ERG-5000-008 EMCO #4 ½ Commercial 100G ERG-5000-008 EMCO #5 Commercial 100G ERG-5000-008 Dresser ROOTS Series B3 8C - 56M 8C - 16M CTR TC (No pulser, No instrument drive) Commercial To attach an Elster American endpoint, install Dresser's Elster American AMR adapter kit. 100G 100G Datalogging Dresser adapter P/N 059599-000 ERG-5000-001 ERG-5002-001 Dresser ROOTS Series A1 (LMMA) CTR Commercial To attach an Elster American endpoint, install Dresser's Elster American AMR adapter kit. 100G 100G Datalogging Dresser adapter P/N 058530-610 ERG-5000-001 ERG-5002-001 1.5M - 5M (No pulser, No instrument drive) Endpoint Type Endpoint Part No. Dresser ROOTS Series A1 (LMMA) 7M - 16M CTR (No pulser No instrument drive) Commercial To attach an Elster American endpoint, install Dresser's Elster American adapter kit. 100G 100G Datalogging Dresser adapter P/N 058531-610 ERG-5000-001 ERG-5002-001 Dresser ROOTS Series A1 (LMMA) TC (No pulser No instrument drive) Commercial To attach an Elster American endpoint, install Dresser's Elster American AMR adapter kit. 100G 100G Datalogging Dresser adapter P/N 058224-641 ERG-5000-001 ERG-5002-001 1.5M - 16M Dresser ROOTS 5C/8C15 Series Z compact meter Commercial To attach an Elster American endpoint, install Dresser's Elster American adapter kit. 100G 100G Datalogging Dresser adapter P/N 059847-000 ERG-5000-001 ERG-5002-001 Dresser ROOTS B3/LMMA Instrument drive Commercial Standard index drive and no instrument. 100G ERG-5000-007 CD/TD 100G Datalogging Installation Guide - Direct Mount Chapter 1 100G Datalogging Gas Endpoint Installation Prerequisites Prior to installation, verify you have the following items: 1. 100G Datalogging Gas Endpoints designed for your specific brand of residential or commercial gas meters (endpoints include new tamper seals). 2. A compatible meter (see the Meter Compatibility List on page 2). 3. A compatible index. Itron 100G Datalogging Gas Endpoints are compatible with standard dial and direct-read (odometer) indexes. Exceptions are noted on the Meter Compatibility List on page 2. 4. Installation tools (provided by installer or customer) • Small and medium flat-blade or Phillips screwdrivers - to remove and tighten index and index-cover screws. • Side-cutting plier/wire snips - to cut wire seals, if applicable. • Small putty knife - residential meters. • Meter seals, wire seal, and seal press - to protect the meter from tampering, if applicable. • 11/32-inch nut driver or other blunt tool - to securely seat new tamper plugs over screw holes. • FC200SR handheld computer with Endpoint-Link® or EndPoint-Link Pro® software - to program and check 100G Datalogging Gas Endpoint installation and operation. Caution The 100G Datalogging Gas Endpoints can only be programmed using ® ® FC200SR Handheld Computers loaded with EndPoint-Link or EndPoint-Link Pro software version 5.3 or later. 100G Datalogging Installation Guide - Direct Mount Installation Prerequisites • Replacement screws - to mount the 100G Datalogging Gas Endpoint assembly to the meter and the index to the endpoint housing: Replacement Screws Meter To mount the 100G Datalogging Gas Endpoint on the meter: Itron Part Number Elster American 1/4 - 20 x 5/8" slotted, Fillister head 8 - 32 x 3/16" slotted, round pan-head Sensus/Rockwell 10 - 24 x 5/8" slotted Fillister head 6 - 32 x 5/8" slotted, round pan-head Itron/Actaris 10 - 24 x 5/8" slotted Fillister head 10 - 24 x 1/4" slotted, round pan-head National/Lancaster 10 - 24 x 3/4" Phillips flathead stainless steel SCR-0014-004 To mount the index on the Itron Part 100G Datalogging Gas Number Endpoint housing: 6 - 19 x 3/8" thread-forming, Phillips pan-head to mount indexes with legs 6 - 19 x 3/8" thread-forming, Phillips, Fillister head to mount indexes with screw holes Commercial Meter Elster American Sensus/Rockwell To mount the 100G Datalogging Commercial endpoint on the meter: SCR-0015-001 SCR-0037-001 Itron Part Number To mount the index (and Itron Part index assembly, if Number applicable) on the 100G Datalogging Commercial endpoint housing: 2A x 3.25" length, slotted SCR-0062-001 12 - 24 x 1/2" slotted, Fillister round-head drilled to accept (Elster American) head machine screws, drilled utility-approved wire seals to accept utility-approved wire seals 2A x 3.63" length, slotted SCR-0062-002 round-head drilled to accept utility-approved wire seals 100G Datalogging Installation Guide - Direct Mount 2A x 2.94" length, slotted round-head SCR-0062-003 Chapter 1 10 100G Datalogging Gas Endpoint 100G Datalogging Installation Guide - Direct Mount CHAPTER 2 Elster American Meter Installation This chapter provides instructions to install the 100G Datalogging Gas Endpoint on an Elster American Meter. Installing the 100G Datalogging Gas Endpoint involves four tasks: 1. Removing the index from the meter. 2. Assembling the 100G Datalogging Gas Endpoint and index. 3. Programming the 100G Datalogging Gas Endpoint assembly. 4. Attaching the 100G Datalogging Gas Endpoint assembly to the meter. Note Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises. To remove the index from the meter 1. Remove the four index cover screws and the index cover from the Elster American meter. Alternate screw removal following the numbered pattern in the photo. 100G Datalogging Installation Guide - Direct Mount 11 Chapter 2 Elster American Meter Installation 2. Examine the mounting screws. If they are 5/8" long and not corroded, keep them to reattach the 100G Datalogging Gas Endpoint assembly. If the screws are not the correct length or if the screws are corroded, discard. Note You may use the removed index cover as a temporary storage container for screws. Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises. 3. Unscrew one index mounting screw completely. Hold one hand under the index to catch the screw. While removing the other mounting screw, pull the index away from the meter to keep the index backplate against the back of the screw. Remove the screw completely after the index is free of the meter. Set the index aside where it will not be damaged or fill with dirt, rain or snow. The index will be mounted to the endpoint later in this procedure. Verify the index mounting screws are 3/16" long and not corroded. If the screws are the correct length and not corroded, retain for later use. If the original screws were discarded, use the correct replacement screws (see Installation Prerequisites on page 8.) 4. Remove the old gasket, gasket residue and dirt from the meter (if applicable). The meter face must be free of gasket residue before you install the 100G Datalogging Gas Endpoint. 12 100G Datalogging Installation Guide - Direct Mount Installation Prerequisites To Assemble the 100G Datalogging Gas Endpoint and Index 1. Separate the 100G Datalogging Gas Endpoint housing from the cover by pulling the cover straight out from the housing. 2. Set the endpoint cover aside where it will not be damaged or fill with rain, dirt or snow. The cover will be used later in this installation procedure. 100G Datalogging Installation Guide - Direct Mount 13 Chapter 2 Elster American Meter Installation Note Elster American meter indexes are available in different models: Index wrigglers on one-foot meters with drive slots Index meters on two-foot meters with drive posts An Elster American index with mounting screw holes An Elster American index with mounting slots If your index has mounting screw slots, skip steps 3 and 4. If your index has mounting screw holes, perform steps 3 and 4, and skip steps 5 and 6. 3. Using the original index mounting screw or a replacement screw, if necessary, place one 8 - 32 3/16" screw into the index's right-hand mounting screw hole. 14 100G Datalogging Installation Guide - Direct Mount Installation Prerequisites 4. Attach the screw to the endpoint housing's right-index mounting post just enough to hold the screw and the right end of the index in place. 5. Screw one 8 - 32 x 3/16" screw into the right index mounting post one or two turns. Do not tighten the screw. 6. Place the right index mounting screw slot under the screw head. Do not tighten the screw. 7. Slide the index drive post into the endpoint wriggler. Verify positive engagement. Caution If the index wriggler has a drive slot, place the endpoint wriggler's drive post into the index drive slot. Failure to mate the endpoint wriggler with the index drive post (or slot) can cause binding and lead to poor registration or meter failure. 8. Install and tighten the left index mounting screw (for indexes with either mounting screw slots or holes). Tighten the right index mounting screw. 100G Datalogging Installation Guide - Direct Mount 15 Chapter 2 Elster American Meter Installation 9. Slide the endpoint cover over the index and housing. Verify the cover is installed correctly. The endpoint label should be clearly visible and easily read. Programming the 100G Datalogging Gas Endpoint Assembly The 100G Datalogging Gas Endpoint must be programmed with the FC200SR handheld computer loaded with EndPoint-Link® or Point-Link Pro® software version 5.3 or later. See the Endpoint-Link v5.3 (or later) Endpoint Programming Guide (TDC-0744) for more complete programming information. Caution The 100G Datalogging Gas Endpoint must be programmed before use. Follow the steps in this section to properly program the endpoint. 16 100G Datalogging Installation Guide - Direct Mount Programming the 100G Datalogging Gas Endpoint Assembly The endpoint is programmed based on the meter's drive rate. Take note of the index drive rate shown on a lower left dial on the index. The endpoint is programmed based on the drive rate. Elster American meter index drive rates are either 1-cubic foot or 2-cubic feet. To Program the 100G Datalogging Gas Endpoint 1. Program the meter drive rate into the 100G Datalogging Gas Endpoint using the FC200SR. For all programming and "Check Endpoint" operations, hold the FC200SR as close to vertical as possible. For best success, keep the FC200SR within 6 feet of the target endpoint. Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the mode defined by your system administrator. During programming, the 100G Datalogging Gas Endpoint is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the endpoint assembly will read to the nearest cubic foot. 2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the index drive rate. This verifies the endpoint is counting properly after assembly. Caution Do not turn the drive wriggler faster than one turn per second. 3. Read the 100G Datalogging Gas Endpoint using the FC200SR. • If the read result is higher than the number programmed in Step 1, the 100G Datalogging Gas Endpoint is counting correctly. • If the read result is not higher than the number programmed in Step 1, replace the 100G Datalogging Gas Endpoint. 100G Datalogging Installation Guide - Direct Mount 17 Chapter 2 Elster American Meter Installation Attaching the 100G Datalogging Gas Endpoint Assembly to the Elster American Meter After 100G Datalogging Gas Endpoint programming is complete, attach the endpoint assembly to the Elster American Meter. Warning For 5B Meters only: If the 100G Datalogging Gas Endpoint will be installed on a 5B-225 aluminum meter, cut 1/16" off each endpoint wriggler post to prevent the wriggler from rubbing on the face of the nut holding the meter drive dog in place. To Attach the 100G Datalogging Gas Endpoint 1. Align the endpoint wriggler to connect with the drive post (or slot) of the meter. For one-foot meters: Align the endpoint assembly wriggler perpendicular to the meter drive post. For two-foot meters: Align the endpoint assembly wriggler perpendicular to the meter drive slot. The pin on the endpoint wriggler may be installed inside or outside the meter drive slot. For easy assembly, Itron recommends installing the pin on the 100G Datalogging Gas Endpoint wriggler outside the meter drive slot. 18 100G Datalogging Installation Guide - Direct Mount Attaching the 100G Datalogging Gas Endpoint Assembly to the Elster American Meter 2. Carefully align the endpoint's four screw holes with the holes on the meter. Attach using the original mounting screws if they are the correct size and are not corroded (1/4 - 20 x 5/8" screws.) If the original screws were discarded, use the correct replacement screws (see Installation Prerequisites on page 8). Tighten in an alternating, diagonal pattern as shown in the photo: • Insert first screw and tighten 1/4 to 1/2 turn after the screw contacts the meter connection. • Insert the second screw and tighten 1/4 to 1/2 turn after contact with the meter connection. • Insert the third screw and tighten 1/4 to 1/2 turn after contact with the meter connection. • Insert the last screw and tighten 1/4 to 1/2 turn after contact with the meter connection. Return to the first screw and tighten. Continue with the second, third and last screw until all screws are tight. Use equal screw tension to tighten each screw. Note Meter manufacturers should torque the mounting screws 15 to 20 inchpounds. 3. Place new tamper seals over the two screws with tamper seal mounts. Press tamper seals into place using the 11/32" nut driver or similar blunt tool. 100G Datalogging Installation Guide - Direct Mount 19 Chapter 2 Elster American Meter Installation 4. Complete necessary paperwork and verify all excess materials are removed from the customer's premises. 100G Datalogging Gas Endpoint installation on the Elster American meter is complete. 20 100G Datalogging Installation Guide - Direct Mount
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Itron Create Date : 2009:04:22 09:19:11-05:00 Modify Date : 2009:04:22 09:19:21-05:00 Subject : Gas Solutions Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2009:04:22 09:19:21-05:00 Creator Tool : Acrobat PDFMaker 9.1 for Word Format : application/pdf Title : 100G Datalogging Installation Guide - Direct Mount Description : Gas Solutions Creator : Itron Document ID : uuid:1dde0f21-cd0d-4660-9002-f82c8e44ea28 Instance ID : uuid:b7c9006c-cc00-4800-9356-172335e1c56f Producer : Adobe PDF Library 9.0 Page Count : 26EXIF Metadata provided by EXIF.tools