Itron 100GDLCN AMR transceiver device for utility meters User Manual 100G Datalogging Installation Guide Direct Mount

Itron Inc AMR transceiver device for utility meters 100G Datalogging Installation Guide Direct Mount

Users Manual 1

Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  57   Proprietary and Confidential     To attach the 100G Datalogging commercial gas endpoint to the Elster American Meter commercial meter    Warning  Handle the 100G Datalogging commercial gas endpoint carefully so the metal passive radiator antenna is not damaged.  1. Tilt the 100G Datalogging commercial gas endpoint at an angle and turn the wriggler until the drive notches line up with the meter wriggler's drive teeth.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  58  Proprietary and Confidential    2. Align the endpoint so the screw holes line up with the meter's top screw holes. Carefully lower the endpoint on the meter with the wriggler notches lining up with the meter's wriggler teeth.  Warning  The INLET label on the 100G Datalogging commercial gas endpoint must line up with the INLET label on the meter case.  3. Verify the bottom of the endpoint and the top of the meter meet. The endpoint housing should rest on top of the meter without gaps.  Warning  Do not press down on the 100G Datalogging commercial gas endpoint if a gap exists between the endpoint and the meter. A gap may be caused by misalignment of the endpoint wriggler and meter wriggler's drive teeth. Pushing down on the endpoint could damage the endpoint wriggler or meter drive teeth. To eliminate a gap, slowly turn the endpoint's upper wriggler back and forth until the endpoint aligns with the meter's drive teeth.     4.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  59   Proprietary and Confidential     5. Place the index cover mounting plate on the 100G Datalogging commercial gas endpoint so the printing "FLOW FRONT AL800 AL1000 AL1400 AL2300 AL5000 TURBINE ROTARY" stamped on the plate is toward the front of the meter.  (A gap between the mounting plate and meter at the screw locations is normal.)               6. Install four mounting screws included with the 100G Datalogging commercial gas endpoint and tighten them in an alternating diagonal sequence.   For metal mounting plates with a flat screw surface, use endpoint mounting screws with internal tooth washers.   For plastic mounting plates with tamper screw cups, use endpoint mounting screws (Use O-rings AS-568A-011, 5/16" ID x 7/16" OD for a maximum moisture seal). Turn each screw 1/4 to 1/2 turn after it contacts the mounting plate. If you have access to a torque driver, tighten mounting screws to 72 inch-pounds.  7. Place new tamper seals over screws (if mounting plate has tamper seal cups) and press into place with an 11/32" nut driver or similar blunt tool.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  60  Proprietary and Confidential    To attach the index/cover assembly on the meter 1. Place the mounting plate gasket (previously removed) on the index cover mounting plate. Align the gasket and index cover mounting plate screw holes. 2. Place the index/cover assembly on the index mounting plate. (The index must face the direction it faced before removal.) Attach the index/cover assembly on the mounting plate using original index screws. Insert one screw and tighten two turns to hold it in place on the mounting plate. Insert the second mounting screw and tighten until secure. Completely tighten the first mounting screw. Each index cover mounting screw must be tightened evenly. 3. Turn the 100G Datalogging commercial gas endpoint wriggler so it intersects with the index wriggler. Carefully lower the index-cover mounting plate assembly onto the 100G Datalogging commercial gas endpoint.     4. Install four endpoint mounting screws (SCR-0062-001, see Installation Prerequisites on page 7). Tighten screws in an alternating diagonal pattern.   Insert the first screw and tighten enough to hold index assembly in place.   Insert the second screw diagonal to first screw and tighten two to three turns.   Insert the third screw, tightening two or three turns.   Insert the fourth screw and tighten until secure.   Tighten the first, second, and third screws until secure. Turn each screw 1/4 to 1/2 turn after it contacts the cover.  Tighten each endpoint mounting screw evenly. If you have access to a torque-driver, tighten mounting screws to 72-inch pounds. 5. Install new tamper or wire seals. If tamper seals are installed, press into place with an 11/32 nut driver or similar blunt tool. Crimp the seal if utility-approved wire seals are installed.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  61   Proprietary and Confidential     This completes installation of the 100G Datalogging commercial gas endpoint on an Elster American Meter commercial meter.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  62  Proprietary and Confidential    Installing the 100G Datalogging Commercial Gas Endpoint on an Itron Commercial Meter This section provides instructions for installing the 100G Datalogging commercial gas endpoint on Itron/Sprague/Schlumberger 675A, 800A, and 1000A commercial meters. Installation requires an Itron adapter kit available from Itron, Owenton, KY.  Itron Adapter Kit (Part Number 80005901-001) Adapter plate  Endpoint mounting screws (4)  Screw bushings (4)  Tamper seals  Extension driver   Follow Removing the Index/Index Assembly from the Meter on page 52 to prepare the Itron/Schlumberger meter for installation. Program the 100G Datalogging commercial gas endpoint (see Programming the 100G Datalogging Gas Endpoint Assembly on page 55) prior to installation.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  63   Proprietary and Confidential     To attach the 100G Datalogging commercial gas endpoint to the meter 1. Turn the 100G Datalogging commercial gas endpoint over and place the four mounting screw bushings into the screw holes on the endpoint.   2. Turn the 100G Datalogging commercial gas endpoint on its side and align the wriggler with the meter's drive dog.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  64  Proprietary and Confidential    3. Inlet lettering on the 100G Datalogging commercial gas endpoint must line up with Inlet lettering on the meter. Slowly lower the endpoint on the Itron/Sprague/Actaris/Schlumberger commercial meter aligning the drive dog and wriggler. The endpoint housing should rest on the top of the meter without gaps.    Warning  Do not press down on the 100G Datalogging commercial gas endpoint if a gap exists between the endpoint and the meter. A gap may be caused by misalignment of the endpoint wriggler and meter wriggler's drive teeth. Pushing down on the endpoint could damage the endpoint wriggler or meter drive teeth. To eliminate a gap, remove the 100G Datalogging commercial gas endpoint and repeat steps 2 and 3.    To attach the index/cover assembly on the meter 1. Place the Itron adapter plate on the 100G Datalogging commercial gas endpoint with the two small screw holes in the adapter plate to the back of the meter.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  65   Proprietary and Confidential     2. Place the extension driver on the 100G Datalogging commercial gas endpoint wriggler securely.  3. Align the index wriggler with the commercial 100G Datalogging commercial gas endpoint wriggler driver extension.  4. Install the two index mounting screws. Tighten the first screw two or three turns. Install second screw and tighten to secure. Tighten the first screw to a snug fit. Tighten each index mounting screw evenly.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  66  Proprietary and Confidential    5. Place the index cover over the index with the clear side covering the index dials for easy reading. Align the holes in the index cover with the endpoint adapter plate mounting holes. Secure with the four mounting screws from the adapter kit. Tighten the mounting screws in a diagonal alternating pattern.   Insert the first screw and tighten enough to hold the index in place.   Insert the second screw and tighten two to three turns.   Insert the third mounting screw and tighten two to three turns.   Insert the fourth mounting screw and tighten.  Tighten the first, third, and second screws. Turn each screw 1/4 to 1/2 turn after the screw contacts the index cover. Tighten each index mounting screw evenly. If you have access to a torque-driver, tighten mounting screws to 72-inch pounds.  6. Insert tamper seals in the tamper seal cups on the index cover and press into place with an 11/32 nut driver or similar blunt tool.
Elster American and Itron Actaris Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  67   Proprietary and Confidential     This completes installation of the commercial 100G Datalogging commercial gas endpoint on the Itron Commercial meter.
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  68   Proprietary and Confidential     This chapter provides instructions to install the 100G Datalogging commercial gas endpoint on a Commercial Sensus/Rockwell diaphragm meter.   Removing the Index/ Index Assembly from the Meter 100G Datalogging commercial gas endpoints can be mounted on Sensus/Rockwell Commercial Meters in various configurations. These instructions show the index assembly mounted without a mounting plate.  Note Sensus/Rockwell diaphragm commercial meters do not require an index assembly mounting plate. Indexes can be mounted directly to the endpoint.     To remove the index/index assembly from the meter 1. Remove any tamper seals (or wire seals) from the index cover and remove the index cover mounting screws. You will re-install it later in these instructions.  CH A P T E R   7  Sensus/Rockwell Commercial Meter Installation
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  69   Proprietary and Confidential     2. Remove the index screws from the meter. Set the index cover aside where it will not be damaged or fill with dirt, rain or snow.  You will re-install the index later in this procedure.   Note  Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  70  Proprietary and Confidential    Programming the 100G Datalogging Gas Endpoint Program 100G Datalogging gas endpoints using:  A FC200SR handheld computer with Endpoint-Link® or Endpoint-Link Pro version 5.3 or higher or  A FC300 with SRead handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.5 or higher or  A 900MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. See the Endpoint-Link v5.3 (or higher) Endpoint Programming Guide (TDC-0744) for more complete programming information.        FC200SR               FC300 with SRead        900MHz Belt Clip Radio  Caution  The 100G Datalogging commercial Sensus/Rockwell endpoint must be programmed before use. Follow the steps in this section to properly program the endpoint.  Take note of the index drive rate shown on the index. The endpoint is programmed based on the drive rate. Sensus/Rockwell commercial meter index drive rates may be 5-, 10- or 100-cubic feet. The seven-dial index shown is a 100-cubic feet drive rate.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  71   Proprietary and Confidential     To program the 100G Datalogging commercial gas endpoint 1. Program the index drive rate into the commercial endpoint using the endpoint programming device. For all programming and "Check Endpoint" operations, hold the handheld programmer as close to vertical as possible. For best success, keep the handheld programmer within 6 feet of the target endpoint. Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file loaded into the endpoint programming device.  During programming, the 100G Datalogging commercial gas endpoint is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the endpoint assembly will read to the nearest cubic foot.  2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the index drive rate. This verifies the endpoint is counting properly.   Caution  Do not turn the drive wriggler faster than one turn per second.  3. Read or Check the 100G Datalogging commercial gas endpoint using the endpoint programming device.   If the read result is higher than the number programmed in Step 1, the 100G Datalogging commercial  gas endpoint is counting correctly.   If the read result is not higher than the number programmed in Step 1, replace the 100G Datalogging commercial gas endpoint.  Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commercial Diaphragm Meter    Warning  Handle the 100G Datalogging commercial gas endpoint carefully so the metal passive radiator antenna is not damaged.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  72  Proprietary and Confidential    To attach the 100G Datalogging commercial gas endpoint on the Sensus/Rockwell commercial meter 1. Tilt the 100G Datalogging commercial gas endpoint at an angle and turn the wriggler until the drive notches line up with the meter wriggler's drive teeth.  2. Align the 100G Datalogging commercial gas endpoint so the screw holes line up with the meter's top screw holes. Carefully lower the endpoint on the meter so the wriggler's bars line up with the meter drive dog. Itron recommends installation with one bar inserted into the meter drive dog's u-shaped gear.  Warning  The INLET label on the 100G Datalogging commercial gas endpoint must line up with the INLET label on the Sensus/Rockwell meter case.  3. Verify the bottom of the 100G Datalogging commercial gas endpoint and the top of the meter meet. The endpoint housing should rest on top of the meter without gaps.  Warning  Do not press down on the 100G Datalogging commercial gas endpoint if a gap exists between the endpoint and the meter. A gap may be caused by misalignment of the endpoint wriggler and meter wriggler's drive teeth. Pushing down on the endpoint could damage the endpoint wriggler or meter drive teeth. To eliminate a gap, slowly turn the 100G Datalogging commercial gas endpoint's upper wriggler back and forth until the endpoint aligns with the meter's drive teeth.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  73   Proprietary and Confidential     4. Align the 100G Datalogging commercial gas endpoint with the index mounting holes. Verify the index drive dog intersects with the endpoint's wriggler. Install the endpoint mounting screws (SCR-0062-003 see Installation Prerequisites on page 7 for screw information). Turn each screw 1/4 to 1/2 turn after it contacts the index/endpoint assembly.   5. Install the index cover. For index covers with flat-surface screw holes, use screws (SCR-0062-002), flat washers (WSH-0020-005), and cork washers (WSH-0032-001). For index covers with tamper seal cups, use screws, (AS-568A-011, 5/16" ID x 7/16 OD) O-rings, and tamper seals.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  74  Proprietary and Confidential    6. Place new tamper seals over screws (if mounting plate has tamper seal cups) and press into place with an 11/32" nut driver or similar blunt tool. If your mounting assembly requires a utility-approved wire seal, pass wires through holes in the screw heads and crimp the approved wire seal.  This completes installation of the 100G Datalogging commercial gas endpoint on the Sensus/Rockwell commercial diaphragm meter.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  75   Proprietary and Confidential     Mounting a 100G Datalogging Commercial Gas Endpoint on a Rockwell 750 meter with an Aluminum BOX Direct Reading (VDR) Installing the 100G Datalogging commercial endpoint on a Sensus/Rockwell commercial meter with an Aluminum Box Direct Reading (VDR) Index requires two Itron SCR-0062-001 mounting screws (see Installation Prerequisites on page 7) - purchased separately.    To remove the index from the 1. Remove tamper seals and screws from the top of the Aluminum Box Direct Reading Index. Set the cover and screws aside. You will use them later in the installation.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  76  Proprietary and Confidential    2. Remove the screws holding the aluminum box to the meter.  3. Carefully remove the aluminum box and set it aside. You will use it later in this installation. Program the 100G Datalogging Sensus/Rockwell Commercial endpoint before attaching it to the Sensus/Rockwell meter (see Programming the 100G Datalogging Commercial Gas Endpoint on page 70).  To install the 100 Datalogging commercial gas endpoint on a Rockwell 750  meter with an Aluminum Box Direct Reading (VDR) Index 1. Using a side-cutter, remove the two rear housing pins from the 100G Datalogging commercial endpoint.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  77   Proprietary and Confidential     2. Tilt the 100G Datalogging commercial gas endpoint at an angle and turn the wriggler until the drive notches line up with the meter wriggler's drive teeth.  3. Align the 100G Datalogging commercial gas module so the screw holes line up with the meter's top screw holes. Carefully lower the module on the meter so the wriggler's bars line up with the meter drive dog. Itron recommends installation with one bar inserted into the meter drive dog's u-shaped gear.  Warning  The INLET label on the 100G Datalogging commercial gas module must line up with the INLET label on the Rockwell meter case.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  78  Proprietary and Confidential    4. Verify the bottom of the 100G Datalogging commercial gas endpoint and the top of the meter meet. The endpoint housing must rest on top of the meter without gaps.   Warning  Do not press down on the 100G Datalogging commercial gas endpoint if a gap exists between the module and the meter. A gap may be caused by misalignment of the module wriggler and meter wriggler's drive teeth. Pushing down on the endpoint could damage the module wriggler or meter drive teeth. To eliminate a gap, slowly turn the 100G Datalogging commercial gas endpoint's upper wriggler back and forth until the module wriggler aligns with the meter's drive teeth.  5. Align the index drive wriggler with the 100G Datalogging wriggler and mounting holes. Attach using two SCR-0062-001 Itron mounting screws.
Sensus/Rockwell Commercial Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  79   Proprietary and Confidential     6. Attach the index cover with the original index cover screws and insert tamper seals in the tamper seal cups. Push tamper seals into place using an 11/32" nut driver or similar blunt tool.  This completes installation of the 100G Datalogging commercial endpoint with an Aluminum Box Direct Reading (VDR) Index on a Sensus/Rockwell commercial meter.
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount 80   Proprietary and Confidential     This chapter provides the instructions to mount 100G Datalogging gas endpoints (residential and commercial) on Dresser ROOTS® Commercial Rotary Meters. Some commercial AMR applications require a Dresser ROOTS® Rotary Meter with a residential 100G Datalogging gas endpoint. Only Elster American version residential 100G Datalogging gas endpoints are compatible with Dresser ROOTS® series rotary gas meters. This chapter provides the instructions to mount an Elster American residential 100G Datalogging gas endpoint on Dresser ROOTS® AMR-ready Rotary Commercial Meters.  Installation requires an AMR adapter kit supplied by Dresser. Refer to the Meter Compatibility List on page 2 for Dresser AMR adapter kit part numbers.  Installation Prerequisites Materials Supplied By Itron  100G Datalogging gas endpoint  New tamper seals - if applicable Materials Supplied by You  AMR-ready Dresser ROOTS® Rotary Meter   Adapter Kit from Dresser   Elster American Meter index if mounting to 5C15 or 8C15 Rotary Meter  Note  Follow the Dresser Field Installation Instructions to modify the AMR-ready Dresser ROOTS® Meter for 100G Datalogging gas endpoint installation. Contact Dresser distributor or Dresser representative for installation instructions specific to the required AMR adapter kit.    CH A P T E R   8  Dresser ROOTS® Commercial Rotary Meter Installation
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  81   Proprietary and Confidential     Installation Examples The following pictures show typical installations. Dresser B3 CTR/TC     Dresser LMMA CTR   Dresser LMMA TC  Dresser 8C15
Dresser ROOTS® Commercial Rotary Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  82  Proprietary and Confidential    Programming the 100G Datalogging Gas Endpoint Assembly Program the 100G Datalogging gas endpoints using:  A FC200SR handheld computer with Endpoint-Link® or Endpoint-Link Pro version 5.3 or higher or  A FC300 with SRead handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.5 or higher or  A 900MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. See the Endpoint-Link v5.3 (or higher) Endpoint Programming Guide (TDC-0744) for more complete programming information.       FC200SR               FC300 with SRead        900MHz Belt Clip Radio  Caution  The 100G Datalogging gas endpoint must be programmed before use. Follow the steps in this section to properly program the endpoint.  For 5C15 and 8C15 Rotary Meters, program as 4 dial, 2 cubic foot index. For all other residential 100G Datalogging gas endpoints, refer to B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive Programming Information on page 84.
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  83   Proprietary and Confidential     To program the 100G Datalogging gas endpoint 1. Program the meter drive rate into the 100G Datalogging gas endpoint using the endpoint programming device. For all programming and "Check Endpoint" operations, hold the handheld computer as close to vertical as possible. For best success, keep the handheld computer within 6 feet of the target endpoint. Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file loaded into the endpoint programming device. During programming, the 100G Datalogging gas endpoint is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the endpoint assembly will read to the nearest cubic foot.  2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the index drive rate. This verifies the endpoint is counting properly after assembly.   Caution  Do not turn the drive wriggler faster than one turn per second.  3. Read or Check  the 100G Datalogging gas endpoint using the endpoint programming device.   If the read result is higher than the number programmed in Step 1, the 100G Datalogging gas endpoint is counting correctly.   If the read result is not higher than the number programmed in Step 1, replace the 100G Datalogging gas endpoint.   B3, LMMA, and S3A CTR/TC Dresser ROOTS® Series Register Settings and Direct Drive Programming Information Use the information in the following tables to program Dresser ROOTS® Series B3, LMMA, and S3A Non-compensated Counter (CTR) and Temperature Compensated (TC) registers. Reference the Meter Compatibility List to confirm compatibility. Settings for Series B3 Registers Settings for LMMA Registers Model Meter size Settings Model Meter Size Settings CTR 8C-15C and 2M-11M    16M-56M Number of dials: 5 Drive rate: 10 PCOMP factor: NONE  Number of dials: 6 Drive rate: 100 PCOMP factor: NONE CTR 1.5M-11M    16M Number of dials: 5 Drive rate: 10 PCOMP factor: NONE  Number of dials: 6 Drive rate: 100 PCOMP factor: NONE
Dresser ROOTS® Commercial Rotary Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  84  Proprietary and Confidential    TC 8C-15C and 2M-11M    16M  Number of dials: 5 Drive rate: 100 PCOMP factor: NONE  Number of dials: 6 Drive rate: 1000 PCOMP factor: NONE TC 1.5M-11M    16M Number of dials: 5 Drive rate: 50 PCOMP factor: NONE  Number of dials: 6 Drive rate: 500 PCOMP factor: NONE  Settings for Series S3A Registers Model Meter Size Settings CTR 1.5M - 11M    16M Number of dials: 5 Drive rate: 10 PCOMP factor: NONE  Number of dials: 6 Drive rate: 100 PCOMP factor: NONE TC 1.5M - 11M    16M Number of dials: 5 Drive rate: 100 PCOMP factor: NONE  Number of dials: 6 Drive rate: 1000 PCOMP factor: NONE B3, LMMA and S3A CTR/TC Meter Drive Rates: Residential Direct Drive Programming*  B3 CTR Meter Size B3 CTR Meter Drive Rate B3 TC Meter Size B3 TC Meter Drive Rate 8C 10 8C 100 11C 10 11C 100 15C 10 15C 100 2M 10 2M 100 3M 10 3M 100 5M 10 5M 100 7M 10 7M 100 11M 10 11M 100 16M 100 16M 1000 23M 100   38M 100
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  85   Proprietary and Confidential     B3 CTR Meter Size B3 CTR Meter Drive Rate B3 TC Meter Size B3 TC Meter Drive Rate 56M 100   LMMA CTR Meter Size LMMA CTR Meter Drive Rate LMMA TC Meter Size LMMA TC Meter Drive Rate 1.5M 10 1.5M 50 3M 10 3M 50 5M 10 5M 50 7M 10 7M 50 11M 10 11M 50 16M 100 16M 500 S3A CTR Meter Size S3A CTR Meter Drive Rate S3A TC Meter Size S3A TC Meter Drive Rate 1.5M 10 1.5M 100 3M 10 3M 100 5M 10 5M 100 7M 10 7M 100 11M 10 11M 100 16M 100 16M 1000  Caution  Drive rates in these tables are for direct-mount residential style endpoints only (NOT commercial or remote endpoints).    Note  S3A rotary meters are LMMA meters retrofitted with a Series 3 accessory.   Installing the Residential 100G Datalogging Gas Endpoint Assembly to the Dresser ROOTS® Rotary Meter After 100G Datalogging gas endpoint programming is complete, attach the endpoint assembly to the Dresser ROOTS® Rotary Meter. This mounting procedure applies to B3 CTR/TC, LMMA CTR/TC, and 8C15 series Dresser ROOTS® Meters.  To attach the 100G Datalogging gas endpoint Refer to Installation Examples on page 81. 1. The 100G Datalogging gas endpoint must be mounted on the adapter plate in an upright position. Align the 100G Datalogging gas endpoint wriggler with the opening between the tabs of the adapter's drive dog.    Insert one endpoint mounting screw and tighten enough to hold the endpoint. Do not completely tighten.   Insert the second mounting screw and tighten two turns.   Insert the third mounting screw and tighten two turns.
Dresser ROOTS® Commercial Rotary Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  86  Proprietary and Confidential     Insert the last mounting screw and tighten until snug. Tighten the remaining mounting screws in an alternating, diagonal pattern until snug. Tighten all mounting screws evenly.   Warning  A gap may be caused by misalignment of the endpoint wriggler and meter wriggler's drive teeth. Pushing down on the endpoint could damage the endpoint wriggler or meter drive teeth. To eliminate a gap, remove the endpoint assembly and re-align the endpoint wriggler with the meter drive dog. 2. Complete necessary paperwork and verify all excess materials are removed from the customer's premises. 100G Datalogging residential gas endpoint installation on the Dresser ROOTS®  Rotary Meter is complete.  Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS® Rotary Meter with an Instrument Drive The information in this section guides you through the installation of the 100G Datalogging commercial gas endpoint on Dresser ROOTS® rotary meters.   Note  This installation procedure requires a Dresser ROOTS® rotary gas meter with an instrument drive. These instructions show an Elster American 100G Datalogging commercial gas endpoint. The installation procedure is identical for the Sensus/Rockwell 100G Datalogging commercial gas endpoint.
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  87   Proprietary and Confidential      100G Datalogging Elster American Commercial Gas Endpoint   100G Datalogging Sensus/Rockwell Commercial Gas Endpoint  Installation Overview Installation requires the following items:  One index mounting plate (if applicable)  Gasket and drive cover kit (if applicable)  An Elster American Meter or Sensus/Rockwell 100G Datalogging commercial gas endpoint   A flat, slot-drive screwdriver
Dresser ROOTS® Commercial Rotary Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  88  Proprietary and Confidential    Programming the 100G Datalogging Commercial Gas Endpoint Assembly Program the 100G Datalogging gas endpoints using:  A FC200SR handheld computer with Endpoint-Link® or Endpoint-Link Pro version 5.3 or higher or  A FC300 with SRead handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.5 or higher or  A 900MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. See the Endpoint-Link v5.3 (or higher) Endpoint Programming Guide (TDC-0744) for more complete programming information.       FC200SR               FC300 with SRead        900MHz Belt Clip Radio  Caution  The 100G Datalogging gas endpoint must be programmed before use. Follow the steps in this section to properly program the endpoint.  The endpoint is programmed based on the meter's drive rate. See B3, LMMA, and S3A CD/TD Dresser ROOTS® Series Meter Drive Rates on page 89.
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  89   Proprietary and Confidential     To Program the 100G Datalogging commercial gas endpoint 1. Program the meter drive rate into the 100G Datalogging Commercial Gas Endpoint using the endpoint programming device. For all programming and "Check Endpoint" operations, hold the handheld programmer as close to vertical as possible. For best success, keep the handheld programmer within 6 feet of the target endpoint. Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file loaded into the endpoint programming device. During programming, the 100G Datalogging Commercial Gas Endpoint is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the endpoint assembly will read to the nearest cubic foot.  2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the index drive rate. This verifies the endpoint is counting properly after assembly.   Caution  Do not turn the drive wriggler faster than one turn per second.  3. Read or Check  the 100G Datalogging Commercial Gas Endpoint using the endpoint programming device.   If the read result is higher than the number programmed in Step 1, the 100G Datalogging Commercial Gas Endpoint  is counting correctly.   If the read result is not higher than the number programmed in Step 1, replace the 100G Datalogging Commercial Gas Endpoint.
Dresser ROOTS® Commercial Rotary Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  90  Proprietary and Confidential    B3, LMMA, and S3A CD/TD Dresser ROOTS® Series Meter Drive Rates Use the information in the following tables to program 100G Datalogging commercial gas endpoints installed on Dresser ROOTS® Series B3, LMMA, and S3A registers. Reference the Meter Compatibility List to confirm compatibility.  Warning  Drive rates listed in the following tables are for commercial module programming. Do not use these settings to program residential or remote modules.  B3 CD Meter Size B3 CD Meter Drive Rates B3 TD Meter Size B3 TD Meter Drive Rate 8C 10 8C 100 11C 10 11C 100 15C 10 15C 100 2M 10 2M 100 3M 10 3M 100 5M 10 5M 100 7M 10 7M 100 11M 10 11M 100 16M 100 16M 1000 23M 100   38M 100   56M 100    LMMA CD Meter Size LMMA CD Meter Drive Rate LMMA TD Meter Size LMMA TD Meter Drive Rate 1.5M 10 1.5M 100 3M 10 3M 100 5M 10 5M 100 7M 10 7M 100 11M 10 11M 100 16M 100 16M 1000
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  91   Proprietary and Confidential      S3A CD Meter Size S3A CD Meter Drive Rate S3A TD Meter Size S3A TD Meter Drive Rate 1.5M 100 1.5M 100 3M 100 3M 100 5M 100 5M 100 7M 100 7M 100 11M 100 11M 100 16M 1000 16M 1000  Note S3A rotary meters are LMMA meters retrofitted with Series 3 accessory.  To attach the 100G Datalogging commercial gas endpoint to the meter  Note  A cover is installed on the 100G Datalogging commercial gas endpoint mounted to a Dresser ROOTS® Meter with S3A LMMA Accessory Units (or other Dresser ROOTS® adapters with odometer gauges). 1. Locate the INSTRUMENT FACE stamp (1) and position the meter with the drive dog (2) centered (as shown).    Warning  Handle the commercial 100G Datalogging commercial gas endpoint carefully so the metal passive radiator antenna is not damaged.
Dresser ROOTS® Commercial Rotary Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  92  Proprietary and Confidential    2. Locate the INLET (1) stamp on the endpoint and position the endpoint as shown. Verify the 100G Datalogging commercial gas endpoint wriggler (3) and drive dog shaft (2) are aligned (See To attach the 100G Datalogging commercial gas endpoint to the Elster American commercial meter on page 57 or To attach the 100G Datalogging commercial endpoint on the Sensus/Rockwell commercial meter on page 72.  3. Verify the endpoint wriggler and drive dog shaft are engaged by turning the commercial endpoint wriggler. When properly engaged, you will feel resistance. 4. Place the customer-supplied index mounting plate on the endpoint and install the four mounting screws. Do not disturb the shaft alignment.   5. Install the four 100G Datalogging commercial gas endpoint mounting screws (supplied with the commercial endpoint). Tighten mounting screws in an alternating, diagonal sequence.  Turn each screw 1/4 to 1/2 turn after it contacts the cover.    If you can utilize a torque wrench, tighten to 72 inch-pounds.  Tighten each endpoint mounting screw evenly.
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  93   Proprietary and Confidential     6. Insert new utility-approved wire seals and crimp (if required).   Note To mount an index and index cover on a rotary meter without an accessory odometer unit, remove the domed cover and reference To attach the index/cover assembly on the meter on page 64.
Dresser ROOTS® Commercial Rotary Meter Installation   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  94  Proprietary and Confidential    Completed Installation Examples 100G Datalogging Elster American Commercial  Gas Endpoint mounted on a Dresser ROOTS® Meter with an Instrument Drive  100G Datalogging Sensus/Rockwell Commercial Gas  Endpoint mounted on a Dresser ROOTS® Meter with an Instrument Drive
 TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  95   Proprietary and Confidential      Symbols & Numbers 100G Datalogging Gas Endpoint • 1 A Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commercial Diaphragm Meter • 71 Attaching the 100G Datalogging Gas Endpoint Assembly to Flat-faced Sprague Meters • 35 Attaching the 100G Datalogging Gas Endpoint Assembly to the Itron/Sprague Meter • 32 Attaching the 100G Datalogging Gas Endpoint Assembly to the Meter • 49, 16 Attaching the 100G Datalogging Gas Endpoint Assembly to the Sensus Meter • 25 B B3, LMMA, and S3A CD/TD Dresser ROOTS® Series Meter Drive Rates • 90 B3, LMMA, and S3A CTR/TC Dresser ROOTS® Series Register Settings and Direct Drive Programming Information • 83 D Dresser ROOTS® Commercial Rotary Meter Installation • 80 E Elster American and Itron Commercial Meter Installation • 52 Elster American Meter Installation • 10 I Installation Examples • 81 Installation Overview • 9 Installation Prerequisites • 7 Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS® Rotary Meter with an Instrument Drive • 86 Installing the 100G Datalogging Commercial Gas Endpoint on an Itron Commercial Meter • 62 Installing the Residential 100G Datalogging Gas Endpoint Assembly to the Dresser ROOTS® Rotary Meter • 85 Itron/Sprague Meter Installation • 28 M Meter Compatibility List • 2 Mounting a 100G Datalogging on a Rockwell 750 meter with an Aluminum BOX Direct Reading (VDR) • 75 N National/Lancaster Meter Installation • 42 P Programming the 100G Datalogging Commercial Gas Endpoint • 55 Programming the 100G Datalogging Commercial Gas Endpoint Assembly • 88 Programming the 100G Datalogging Gas Endpoint • 70 Programming the 100G Datalogging Gas Endpoint Assembly • 82, 48, 31, 23, 15 R Removing the Index/ Index Assembly from the Meter • 68, 52 S Securing Brass Meter Tags to Flat-faced Meters • 39 Sensus/Rockwell Commercial Meter Installation • 68 Sensus/Rockwell Meter Installation • 19 Specifications • 2 T To assemble the 100G Datalogging Gas Endpoint and index • 45, 29, 21, 12 To Attach • 85 To attach the 100G Datalogging Commercial Endpoint on the Sensus/Rockwell commercial meter • 72 To attach the 100G Datalogging commercial gas endpoint to the Elster American Meter commercial meter • 57 To attach the 100G Datalogging commercial gas endpoint to the meter • 91 To attach the 100G Datalogging commercial gas endpoint to the meter • 63 To attach the 100G Datalogging Gas Endpoint assembly to Flat-faced • 36 Index
Index   TDC-0823-005     100G Datalogging Installation Guide - Direct Mount  96  Proprietary and Confidential    To attach the 100G Datalogging Gas Endpoint to the meter • 50, 33, 25, 17 To attach the index/cover assembly on the meter • 64, 60 To install the 100G Datalogging commercial gas endpoint on a Rockwell 750  meter with an Aluminum Box Direct Reading (VDR) Index • 76 To Program the 100G Datalogging commercial gas endpoint • 89, 71, 56 To program the 100G Datalogging gas endpoint • 83, 49, 32, 24, 16 To remove the index assembly • 53 To remove the index from the • 75 To remove the index from the meter • 10, 19, 28, 42 To remove the index/index assembly from the meter • 68 To secure brass meter tags to flat-faced meters • 39 Transmission Modes • 1