Itron 100GDLRS AMR transceiver device for utility meters User Manual

Itron Inc AMR transceiver device for utility meters Users Manual

Users Manual

Download: Itron 100GDLRS AMR transceiver device for utility meters User Manual
Mirror Download [FCC.gov]Itron 100GDLRS AMR transceiver device for utility meters User Manual
Document ID3396481
Application IDmJnORGGgwozuRIl529lgUQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize206.33kB (2579130 bits)
Date Submitted2017-05-18 00:00:00
Date Available2017-05-24 00:00:00
Creation Date2017-03-09 07:47:21
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2017-03-27 20:27:26
Document Title100G Series Gas ERT Module Installation Guide, Remote Mount
Document CreatorAcrobat PDFMaker 11 for Word
Document Author: TDC-0824-014

Natural Gas Solutions
100G Series Gas ERT Module Installation Guide,
Remote Mount
TDC-0824-014
Identification
100G Series Gas ERT Module Installation Guide, Remote Mount
24 June 2016 TDC-0824-014
100G, 100G DL, 100G DLN, 100G DLS, 100G DLT remote mount gas ERT modules
ERT module part numbers:
100G remote mount ERT module: ERG-5000-501, ERG-5000-502, ERG-5000-503
100G Datalogging remote mount ERT module: ERG-5002-501, ERG-5002-502, ERG-5002-503, ERG-5002-505
100G Datalogging FN remote mount ERT module: ERG-5003-501, ERG-5003-502, ERG-5003-503, ERG-5003-505
100G DLS Datalogging remote mount ERT module: ERG-5006-501, ERG-5006-502, ERG-5006-503, ERG-5006-505
100G DLT Datalogging remote mount ERT module: ERG-5007-501, ERG-5007-502, ERG-5007-503, ERG-5007-505
Copyright
© 2009 - 2016 Itron, Inc. All rights reserved.
Confidentiality Notice
The information contained herein is proprietary and confidential and is provided subject to the condition that (i) it is held in confidence except to the extent required otherwise by law and (ii) it is
used only for the purposes described herein. Any third party given access to this information is similarly bound in writing.
Trademark Notice
Itron is a registered trademark of Itron, Inc.
All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.
Applicable Patents
U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700
Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118
Compliance Statement
This device complies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to
the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference that may cause undesirable operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio or TV technician for help.
Compliance Statement
Déclaration de conformité
This equipment complies with policies RSS-210 and RSS-GEN of the Innovation, Science and Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
Economic Development Canada (ISED) rules. Operation is subject to the following two
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
conditions:
(1) l'appareil ne doit pas produire de brouillage, et
(1) this device may not cause interference, and
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
(2) this device must accept any interference, including interference that may cause
brouillage est susceptible d'en compromettre le fonctionnement.
undesired operation of the device.
Transportation Classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G series remote ERT module is considered an operating
transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation.
Modifications and Repairs
To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's authority to
operate the equipment.
Meter Installation/Removal
In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
Warning Follow these procedures to avoid injury to yourself or others:
•
The lithium battery may cause a fire or chemical burn if it is not disposed of properly.
•
Do not recharge, disassemble, heat above 100º Celsius (212º Fahrenheit), crush, expose to
water, or incinerate the lithium battery.
•
Keep the lithium battery away from children.
•
Fire, explosion, and severe burn hazard.
Warning Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others
might void any maintenance contract with your company. Unauthorized service personnel might also be subject
to shock hazard on some Itron equipment if removal of protective covers is attempted.
Warning Substitution of components may impair intrinsic safety.
Warning Electrostatic Ignition Hazard Ensure area is not hazardous when installing, servicing, cleaning, or
touching the ERT module.
Warning Clean only with a damp cloth.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
ii
Warning ERT modules contain sensitive electronic components which can be damaged if the module is
dropped from heights greater than 36 inches. Product warranty coverage is contingent on not exceeding this drop
height limitation.
Suggestions
If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com.
If you have questions or comments about the software or hardware product, contact Itron Technical Support:
Contact
• Internet: www.itron.com
• E-mail: support@itron.com
• Phone: 1 877 487 6602
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
iii
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
iv
Contents
Before You Begin ........................................................................................................ vii
Document Conventions ..................................................................................................................... vii
Document Purpose ............................................................................................................................ vii
About the 100G Series Gas ERT Module ..................................................................... 1
Transmission Modes ........................................................................................................................... 1
100G DLS ERT Module and Itron Security Manager .......................................................................... 2
Enabling 100G DLS ERT Module Security ............................................................................... 2
100G Series Gas ERT Module Specifications .................................................................................... 3
Related Documents ............................................................................................................................. 3
100G Series Remote ERT Module Meter Compatibility List ............................................................... 4
Installation Prerequisites ..................................................................................................................... 7
Mounting the 100G Series Gas ERT Module ............................................................... 9
Installation Options .............................................................................................................................. 9
Mounting Screw Specifications ................................................................................................. 9
Mounting Installation Considerations ................................................................................................10
Mounting the Remote ERT Module on a Pipe...................................................................................10
Adapter Plate Mounting Positions .....................................................................................................11
Mounting the Remote Gas Module on a Wall or Other Flat Vertical Surface ...................................16
Rotary Meter Installation ............................................................................................. 18
Required Installation Materials Available from Itron ..........................................................................19
Connecting the 100G Series Gas ERT Module to the GE Dresser Rotary Meter Cable ..................19
Connecting and Installing the GE Dresser D800/D1000 Meter ........................................................21
Connecting and Installing the 100G Series Module to the GE Dresser ES3 or ETC........................26
Configuring Index Settings Using the GE Dresser MeterWare Software ..........................................28
Programming the Remote ERT Module for GE Dresser Rotary Meters ...........................................30
B3, LMMA & S3A CTR/TC Meter Drive Rates for Remote ERT Module Programming .........30
Connecting the Remote ERT Module to the Romet Electronically Compensated Meter (ECM2®) .31
Wiring the 100G Series Gas ERT Module to the Romet ECM2® Meter ...........................................32
Mounting the 100G Series Gas ERT Module ....................................................................................32
Romet ECM2/100G Series Gas ERT Module Mounting Option .......................................................33
Installing the Remote ERT Module to the Elster American Meter RPM Series Rotary Meter ..........34
Programming the Remote ERT Module ............................................................................................38
Electronic Instrument Installation .............................................................................. 41
Installation Prerequisites ...................................................................................................................42
Installation Overview ...............................................................................................................42
Programming the Honeywell Instrument Parameters .............................................................43
Item Code Settings .......................................................................................................43
Wiring Dual ERT Modules to a Honeywell Instrument ............................................................45
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
Contents
Wiring the Remote ERT Module to the Honeywell TCI...........................................................47
Honeywell Software Settings ..................................................................................................50
Connecting the Remote Mount ERT to the IMC/W2 or MC2 Cable .......................................52
Installing the ERT Module to the GE Dresser Micro Corrector (IMC/W2 or MC2) .................53
Galvanic Gas Micro Installation ..............................................................................................57
Programming the Galvanic Gas Micro Electronic Volume Corrector ...........................57
Eagle Research Meter Installation ..........................................................................................58
Required Materials ........................................................................................................58
100G Series Communications with the Eagle Research Corrector .............................63
100G Series Remote Module Installation to the Romet AdEM Using a Cannon or PG9
Factory-Installed Pigtail Cable ................................................................................................69
Required Materials ........................................................................................................70
Meter Preparation .........................................................................................................70
Wiring ............................................................................................................................72
Programming the Remote ERT Module ..................................................................................74
Diaphragm Meter Installation ..................................................................................... 77
Tools and Materials Supplied By You ...............................................................................................77
Materials Available from Itron ............................................................................................................78
Replacement Gaskets .............................................................................................................78
Installing the 100G Series Gas ERT Module ....................................................................................79
Installing 100G Series Gas ERT Module Encoders ..........................................................................79
Index Cover Installation Required Materials .....................................................................................84
Programming the Remote ERT Module ............................................................................................86
DATTUS Meter Installation.......................................................................................... 89
Installation Prerequisites ...................................................................................................................89
Programming the DATTUS Meter Parameters .................................................................................89
Installation Overview ...............................................................................................................89
Installing the Remote ERT Module to Itron DATTUS Meters .................................................90
Connecting the Remote ERT Module to a DATTUS meter ....................................................90
Mounting the 100G Series Gas ERT Module Connected to the DATTUS Meter ...................91
Programming the Remote ERT Module ..................................................................................91
Sensus Sonix Meter Installation................................................................................. 93
Programming the Sensus Sonix Meter Parameters ..........................................................................93
Adjusting the Pulse Output for Sonix 600 and 880 Meters .....................................................93
Installing the 100G Series Gas ERT Module with Sensus Sonix Meters ..........................................94
Sensus Sonix2000 Pulse Output Wiring .................................................................................94
Direct Mounting the Remote ERT Module to the Sonix Meter ..........................................................95
Connecting the Remote ERT Module to a Sensus Sonix 600 or 880 Meter .....................................96
Programming the Remote ERT Module ............................................................................................96
Index ............................................................................................................................. 99
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
vi
Before You Begin
Document Conventions
The following documentation conventions are used in this installation guide.
Caution A Caution warns the installer that failure to follow the information in the note could result
in loss of data. Be sure to carefully read a caution note and follow the advice or instructions.
Warning A Warning alerts the installer about potential physical harm to the installer or hardware. It
is critical that you pay strict attention to warning notes, read the information carefully, and follow
the advice or instructions.
Tip A tip provides the installer with extra hints or tips to make a task easier to perform or a concept
easier to understand.
Note A note supplies generic information to the installer. The installer can ignore the information
and continue the task without suffering any adverse consequences.
Document Purpose
This installation guide provides step-by-step instructions for installing the 100G Series remote gas ERT
module on a wide variety of meters and instruments. This installation guide refers to all models of the 100G
remote ERT module as the 100G series remote gas module. Mechanical and electrical installation procedures
are identical. For more information about ERT to meter compatibility, see the 100G Series Remote ERT
Module Meter Compatibility List on page 4.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
vii
Before You Begin
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
viii
CHAPTER 1
About the 100G Series Gas ERT Module
Itron 100G series remote ERT modules are radio-frequency (RF) devices designed to transmit meter data to an
RF meter reading device within transmission distance of the remote ERT module. The 100G remote gas ERT
module was designed with a higher output power than earlier Itron remote gas ERT modules to achieve an
increased RF transmission distance. The 100G series remote gas ERT modules have greater output power to
meet Itron mobile and fixed network requirements. The first generation 100G remote gas ERT module offered
high transmit power capability which increased operational efficiency and reduced infrastructure costs. The
100G Datalogging remote gas ERT module was enhanced to offer higher transmit power with data logging
capability (time-stamped hourly interval data) for both mobile and fixed network applications. Itron's 100G
Datalogging Fixed Network (DLN) remote gas ERT module added improved network performance through a
higher transmit power, accomplished using increased antenna efficiency and more robust optimized
messaging structures. The 100G DLS remote gas modules brings increased efficiency in SCM+ messaging
and adds enhanced network security. SCM+ messages expand the data fields within our standard consumption
message to offer added value. The enhancement of secure communications provides greater protection for
bubble-up and two-way messaging to prevent unauthorized users from gaining access to the system.
The 100G DLT Datalogging gas ERT module (100G DLT) is a hybrid in the Itron line of 100 Series radio
frequency (RF) gas meter modules. The 100G DLT combines the circuit board hardware of the 100G DLS
module with the SCM messaging used in the 100G DLN module. This allows utilities currently using the
SCM messaging in the 100G DLN can upgrade to the 100G DLT without the upgrades required for
programming, enhanced security, or meter reading. The 100G DLT does not offer the optional ISM enhanced
security capability or extended tamper information available in the 100G DLS.
The 100G remote module features tilt and cut cable-tamper reporting and security seals to indicate physical
tampering and minimize theft. Cut cable is reported when the cable is cut or disconnected from the meter,
instrument, or ERT module. 100G ERT module circuitry senses an electrical current break to report a cut
cable tamper event.
Transmission Modes
The 100G series remote gas module can be set to transmit in fixed network, mobile and handheld, hard to read
mobile and handheld, or cellular solutions mode (fixed network applications only).
•
•
•
Fixed Network Mode. The 100G series remote gas module transmits a high-powered network interval
message (NIM) RF message every five minutes. Output power in this mode is 500 milliwatts or +27 dBm.
Interspersed in the high power NIM, the 100G series remote gas module transmits a medium power RF
message at 10 milliwatts or +10 dBm every 60 seconds; expected battery life is 20 years.
Mobile High Power Mode. The 100G series remote gas module transmits a high-powered RF message
every 60 seconds. Output power in this mode is 250 milliwatts or +24dbm; expected battery life is 20
years.
Mobile and Handheld Mode. The 100G series remote gas module transmits a medium-powered RF
message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is
20 years.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
About the 100G Series Gas ERT Module
•
•
(Optional) Hard to Read Mobile and Handheld Mode. The 100G series remote gas module transmits
a high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm;
expected battery life decreases to 15 years in this mode. The hard to read mobile and handheld mode
should only be used for exceptionally hard-to-read applications (such as meters installed on roof tops or in
sub-basements).
Itron Cellular Solutions (ICS) Mode. The 100G DLS module is compatible with the Itron Cellular
Solution and can be programmed for optimum operation with FDM Endpoint Tools Enhanced. In ICS
mode, the 100G DLS transmits a high-powered RF network interval message (NIM) every five minutes.
Output power in this mode is 500 milliwatts or +27 dBm. Interspersed in the high power NIM, the 100G
transmits a medium power RF message at 10 milliwatts or +10 dBm every 60 seconds; expected battery
life is 20 years.
Note ICS mode is for fixed network application only. ICS is optimized to work with the ICS
communications module in Itron’s electric meter. The 100G DLS must be in a full security mode to work
with ICS. This is not part of the ICS mode, but is a system level requirement.
An FCC license is not required to read 100G series remote gas module.
100G DLS ERT Module and Itron Security Manager
The 100G DLS ERT module is a component of Itron's ChoiceConnect system. ChoiceConnect system
enhanced security, provided by Itron Security Manager (ISM), applies to the RF communications between the
handheld computer, Mobile Collector, or Fixed Network system and the ERT module. ISM is available in the
100G DLS module only.
There are two fundamental security processes used in the ChoiceConnect system to ensure system
communication confidentiality and validity.
•
•
Authentication. Authentication is the process of confirming that an artifact is genuine or valid.
Authentication in the 100G DLT remote gas ERT module is the process of verifying a request is from a
valid source and in its original form.
Encryption. Encryption is the process of transforming information to make it unreadable to anyone who
does not have a valid security key. There are two types of encryption, symmetric and asymmetric.
Symmetric encryption uses a shared key to decrypt or encrypt information. Asymmetric encryption uses a
private key to encrypt and a public key to decrypt.
As a component of the Itron ChoiceConnect solution, the 100G DLT remote gas ERT module supports the
security model found in the ChoiceConnect solution for both reading and programming. If the 100G DLT
remote gas ERT module modules are shipped without ChoiceConnect enhanced security enabled (ready to
secure), the utility can—at a later date—configure the ERT modules for ISM enhanced security.
Note Enabling or working with Itron ISM enhanced security requires FDM Endpoint Tools Enhanced.
Enabling 100G DLS ERT Module Security
When 100G DLS ERT modules ship from an Itron factory, each module contains utility factory keys. The
presence of these utility factory keys does not enable the enhanced security; the installer enables the enhanced
100G DLS security at the time the ERT module is deployed or at a later time using an Itron programming
device, Field Deployment Manager Endpoint Tools Enhanced, and programming commands. Initial key
exchange commands are secured using the utility factory keys. For more information about programming the
100G DLS ERT module for security, see the FDM Endpoint Tools Mobile Application Guide (TDC-0934).
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
About the 100G Series Gas ERT Module
100G Series Gas ERT Module Specifications
Functional Specifications
Description
Power Source
100G
Two "A" cell lithium batteries
100G Datalogging
100G Datalogging FN
100G DLS Datalogging
100G DLT Datalogging
One "A" cell lithium battery
Tamper Detection
Tilt and cut cable
FCC Compliance
Part 15 certified
Innovation, Science and Economic
Development Canada (ISED)
RSS-210 certified
Intrinsically Safe per
UL Class I, Division 1, Groups C and D
Product Identification
Numeric and bar coded ERT type and serial number
Construction Materials
Gray polycarbonate housing and back plate with encapsulated electronics
Operational Specifications
Description
Operating Temperatures
-40° to 158° F (-40° to +70° C)
Operating Humidity
5 to 95 percent relative humidity
Program Frequency
908 MHz
Transmit Frequency
Frequency Hopping Spread spectrum 903 to 926.85 MHz in the ISM band
Data Integrity
Verified in every data message
NIM Message
FM modulation; all other messages are AM modulated
Related Documents
Document Title
Document Part Number
100G Series Gas ERT Module Installation Guide, Direct Mount
TDC-0823-XXX
100 Series Modules and CENTRON Bridge Meter Tamper Reference Guide
TDC-1028-XXX
100 Series Gas and Telemetry Module Technology Guide
TDC-0825-XXX
Gas and Telemetry Module Meter Compatibility List
PUB-0117-002
Gas and Telemetry Module Ordering Guide
PUB-0117-001
100G DLS Gas ERT Module Specification Sheet
Publication 101274SP-XX
100G DLN Gas ERT Module Specification Sheet
Publication 100941SP-XX
100G DLT Gas ERT Module Specification Sheet
Publication 101365SP-XX
Field Deployment Manager Endpoint Tools Mobile Application Guide
TDC-0934-XXX
Field Deployment Manager Field Representative's Guide
TDC-0936-XXX
Note The last three digits of the user and installation guides represent the document's revision level. The
revision level is subject to change without notice.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
About the 100G Series Gas ERT Module
100G Series Remote ERT Module Meter Compatibility List
The following table lists meter types compatible with the 100G series remote gas module. Due to continuous
research, product improvements and enhancements, Itron reserves the right to change product or system
specifications without notice.
Eagle Research
Meter Model
Meter Notes
100G Module Type
Itron Part Number Gas Module Notes
MPplus
Volume Corrector
Pulses with 70mS on and
500mS off timing.
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5003-502
ERG-5006-502
ERG-5007-502
XARTU-1
Pulses with 70mS and 100ms
on and 500mS off timing.
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5006-503
ERG-5007-503
Elster American (Canadian)
Meter Model
Meter Notes
100G Module Type
Itron Part Number
10 Metric (10B)
Originally manufactured by Metric 100G Remote
Metal Works
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
Rotary RPM Series
TC, STD CTR
(pulse output
connection)
Must have factory-installed pulser
with connector output. Purchase
correct cable interface from
manufacturer.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
Meter Notes
Must select 2 pulses/second from
pulse output--output frequency
menu.
100G Module Type
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
Itron Part Number
ERG-5003-503
ERG-5006-503
ERG-5007-503
Meter Notes
Pulse width must be set greater
than 100 ms. Firmware version
must be 1.71 or earlier.
100G Module Type
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
Itron Part Number
ERG-5003-503
ERG-5006-503
ERG-5007-503
ERG-5003-505
ERG-5006-505
ERG-5007-505
Rotary meters equipped with
WeigandWire solid state pulsers.
Meter must have factory-installed
pulser with connector output.
Purchase correct cable interface
from GE. Pulser must be version
17 or higher to be compatible.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
Gas Module Notes
Galvanic
Meter Model
GasMicro
Electronic Volume
Corrector
Gas Module Notes
ERT module cut cable
requires customer-supplied
cable capable of terminating
the ERT module white and
blue wires at the meter
interface.
GE Oil & Gas/Dresser Meters
Meter Model
D800/D1000
B3/LMMA Pulse
output
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
Gas Module Notes
ERG-500X-503 and -505
modules interface with this
meter
About the 100G Series Gas ERT Module
GE Oil & Gas/Dresser Meters
Meter Model
Integral Micro
Corrector IMC/W2
Meter Notes
Electronic volume corrector for
Series A (LMMA) and Series B
rotary meters. Must be meter
firmware version 1.94 or earlier.
Pulse width must be set for
125ms. Pulse output must be at
100CF (CM) or higher.
100G Module Type
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
Itron Part Number
ERG-5000-505
ERG-5002-505
ERG-5003-505
ERG-5006-505
ERG-5007-505
Integral Micro
Corrector MC2
Electronic volume corrector for
Series A (LMMA) and Series B
(rotary meters). Must be firmware
version 1.93 or earlier. Pulse
width must be set for 125 ms.
Pulse output must be at 100CF
(CM) or higher.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-505
ERG-5002-505
ERG-5003-505
ERG-5006-505
ERG-5007-505
Series 3 ES3
Electronic TC
100G Datalogging FN Remote
Electronic TC with mechanical
backup. ES3 pulse width must be 100G DLS Datalogging Remote
set greater than 100ms. Firmware 100G DLT Datalogging Remote
version 1.71 or earlier.
ERG-5000-503
ERG-5000-505
ERG-5002-503
ERG-5002-505
ERG-5003-503
ERG-5003-505
ERG-5006-503
ERG-5006-505
ERG-5007-503
ERG-5007-505
Electronic
Temperature
Compensator
(ETC)
Electronic TC with no mechanical
backup. ETC pulse width must be
set greater than 100 ms.
Firmware version 1.71 or earlier.
Gas Module Notes
Both ERT modules are
compatible with this meter
model.
100G Datalogging FN Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
100G DLT Datalogging Remote
ERG-5003-503
ERG-5003-505
ERG-5006-503
ERG-5006-505
ERG-5007-503
ERG-5007-505
Both ERT modules are
compatible with this meter
model.
Gas Module Notes
Honeywell Mercury Instruments
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Electronic
Correctors:
EC-AT
Mini-P
Mini-AT
Mini-Max
Pressure and temperature
electronic volume instruments.
Instruments must have a Form A
board, Form C is NOT supported.
Item #56 Pulse Scaling Factor
must be 2.0. Item #96 Cor Vol
Display must be 7, 6, 5, or 4 digits
(1, 2, 3, or 4 blanks). Item #115
Output Pulse Code must be set at
1, 2, or 4. For 100G connection to
Mini-Max only, Item #115 must be
set at 1 or 2. Item 124 wake up
setting on Honeywell corrector
must be set to 1. Compatible
corrector firmware versions are
2.5020 and 2.73.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-502
ERG-5002-502
ERG-5003-502
ERG-5006-502
ERG-5007-502
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
About the 100G Series Gas ERT Module
Honeywell Mercury Instruments
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Electronic TC
index:
TCI
Temperature Compensating Index.
TCI must have a Form A board,
Form C is NOT supported. Item
#56 Pulse Scaling Factor must be
2.0. Item #96 must be 7, 6, 5, or 4
digits (1, 2, 3, or 4 blanks). Item #
1014 set to the preset "Itron 100G"
selection in the drop-down menu.
Compatible TCI firmware versions
are 1.06, 1.07, and 1.10.
100G Datalogging Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
100G DLT Datalogging Remote
ERG-5002-502
ERG-5002-503
ERG-5003-502
ERG-5003-503
ERG-5006-502
ERG-5006-503
ERG-5007-502
ERG-5007-503
Gas Module Notes
Itron (Actaris, Schlumberger, Sprague)
Meter Model
Meter Notes
100G Module Type
Itron Part Number
1A
Flat-face meter where meter body
and 1A adapter plate have
interference fit issue causing direct
mount solution to be noncompatible.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
305
#2 flat-face meter
100G Remote
100G Datalogging Remote
100G Datalogging RN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
400
#3 flat-face meter
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
675, 1000
Front-mount index
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
Dattus III fM1,
fM2, fM3
For all meter types, pulse width
must be set to .050 seconds. Meter
type 11M or smaller must have
pulse weight minimum of 10 cubic
feet or 1 cubic meter. Meter type
16M or greater must have pulse
weight minimum of 100 cubic feet
or 1 cubic meter.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-502
ERG-5002-502
ERG-5003-502
ERG-5006-502
ERG-5007-502
100G Module Type
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
Itron Part Number
ERG-5000-501
ERG-5002-501
ERG-5003-501
ERG-5006-501
ERG-5007-501
Gas Module Notes
Requires a thicker gasket for
magnet hub to clear index
box.
1-hole gasket: FAB-0014-001
2-hole gasket: FAB-0014-002
3-hole gasket: FAB-0014-003
National (Lancaster)
Meter Model
All Meters
Meter Notes
Where direct mount solution is not
compatible.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
Gas Module Notes
About the 100G Series Gas ERT Module
Romet
Meter Model
RM Series
STD CTR
600—56000
TC 2000—23000
Meter Notes
Meter must have factory-installed
pulser with connector output.
Purchase cable interface from
manufacturer.
100G Module Type
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
Itron Part Number
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
RM Series
Electronically
compensated
meter ECM2
600—56000
Meter must have connector pin
with factory-installed pulse output.
Purchase correct cable interface
from Romet. ECM2 must be
configured for 750ms "off-time"
between pulses. The ECM2 must
have firmware version J or later.
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
®
Must be configured for 750ms "off
time" between pulses
100G DLS Datalogging Remote
100G DLT Datalogging Remote
ERG-5006-503
ERG-5007-503
100G Module Type
100G Remote
100G Datalogging Remote
100G Datalogging FN Remote
100G DLS Datalogging Remote
100G DLT Datalogging Remote
Iron Part Number
ERG-5000-503
ERG-5002-503
ERG-5003-503
ERG-5006-503
ERG-5007-503
AdEM Series
Correctors
®
including AdEM ®
S, AdEM -T, and
®
AdEM -PTZ
Gas Module Notes
Sensus (Invensys/Equimeter/Rockwell/EMCO)
Meter Model
Sonix Pulse
Output
12, 16, 25, 57
(Metric)
600, 880, 2000
(Cubic foot)
Meter Notes
Sonix meters are pulse output
registers which are programmed
by Sensus software. Proper pulse
output options and display options
must be selected.
Gas Module Notes
Installation Prerequisites
The following tools are required to install, program, and check the remote 100G series remote gas module.
Some specific tools may be required dependent on meter or instrument type.
•
•
•
•
•
•
•
•
•
•
•
•
Medium flat-blade screwdriver
Small flat-blade screwdriver
Medium Phillips screwdriver
Hand pliers
Side-cutting pliers
1/4-inch nut driver or similar blunt tool
One-inch width putty knife
Adjustable wrench
3M Scotchlock E-9Y crimping tool, 3M Scotchlock E-9C cartridge tool, or similar crimping tool
All-weather electrical tape
Mounting screws (for more information about mounting screws, see Mounting Screw Specifications on
page 9)
Size T-15 Torx screwdriver
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
About the 100G Series Gas ERT Module
•
Itron programming device:
FC200SR handheld computer with Field Deployment Manager (FDM) software
or
FC300 with SRead with Field Deployment Manager (FDM) software
or
900 MHz Belt Clip Radio with Field Deployment Manager (FDM) and a customer-supplied laptop
Note The FDM version required is dependent upon the 100G ERT module model in use.
Warning ERT modules contain sensitive electronic components which can be damaged if the
module is dropped from heights greater than 36 inches. Product warranty coverage is contingent
on not exceeding this drop height limitation.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
CHAPTER 2
Mounting the 100G Series Gas ERT Module
This chapter provides the instructions to mount the 100G series remote gas module on a pipe or other flat
vertical surface (wall).
Installation Options
Mount the remote ERT module using the pipe mount or wall mount (flat vertical surface) procedure.
•
•
Pipe Mount. Pipe mounting is used in conjunction with the Pipe Installation Kit (Itron part number CFG0005-003). The pipe mount option places the module on a pipe near the meter or instrument (not on a wall
surface). This option requires a meter manufacturer's cable to connect the module to the meter or
instrument.
Flat Vertical (Wall) Mount. Installation using the wall mount option places the module on a wall or
other vertical surface. A cable connects the module to the meter or instrument.
Mounting Screw Specifications
Application
Itron Part
Number
Description
To mount adapter plates on
pipe brackets
575-9930-016
8-16 x 1/2-inch length, type 8 slotted pan-head tapping
screw, corrosion-resistant steel
To mount remote modules on
adapter plates
575-9930-032
8-16 x 1-inch type 8, slotted pan-head tapping screw,
corrosion-resistant steel
To mount remote modules on SCR-0009-001
sheet metal surfaces (to mount
modules to wood surfaces, a
comparable wood screw is
required)
10-16 x 1 1/2-inch type AB thread for sheet metal, Phillips
pan-head tapping screw, corrosion-resistant steel
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
Mounting the 100G Series Gas ERT Module
Mounting Installation Considerations
Select a proper mounting location. Itron recommends mounting the 100G series remote gas module in close
proximity to the meter or instrument. Some applications may require an extended cable-length. The 100G
series remote gas module supports cable lengths up to 300 feet with a recommended one-splice limitation.
Mount the 100G series remote gas module in a vertical position with the ERT label directional arrow pointed
upward.
Caution Upright vertical positioning is very important because:
•
•
100G series remote gas modules are designed with the antenna in a vertical direction
so the antenna is parallel to the reading device (which has a vertical antenna).
Matching antenna polarity can greatly affect RF performance and enable easy ERT
module reading.
100G series remote gas modules are designed so the tilt tamper is vertical. It is
important to maintain vertical positioning in the field to enable tilt tamper stability.
Warning ERT modules contain sensitive electronic components which can be damaged if the
module is dropped from heights greater than 36 inches. Product warranty coverage is contingent on
not exceeding this drop height limitation.
Do not mount the 100G series remote gas module in an orientation other than vertical (remote ERT
module label arrow pointed upward). Violating the mounting orientation requirements may void the
product warranty
Mounting the Remote ERT Module on a Pipe
The following items are required to mount the 100G series remote gas module on a pipe or vertical flat
surface (wall):
Itron Part
Number
Description
ERG-500X-501
ERG-500X-502
ERG-500X-503
ERG-500X-505
100G series remote gas module
(ERG-5006-501 shown)
CFG-0005-003
Pipe Mount Kit Kit includes:
(2) two band clamps
(2) two tamper seals
pipe bracket
cable ties
adapter plate
Screws:
(2) 1/2-inch, to attach the adapter plate to pipe bracket
(2) 1-inch, to attach the ERT module to the adapter plate
(3) 1 1/2-inch, to attach the ERT module to a vertical surface (wall)
Warning Install the 100G series remote gas module in an upright position. Any position other than upright,
may negatively affect radio performance and reduce battery life.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
10
Mounting the 100G Series Gas ERT Module
To mount the pipe bracket on a vertical pipe
Caution A vertical mounting position is important to maximize RF performance. Mount the ERT module
with the module's label arrow pointing up. The module's arrow must never point to either side or upside
down. The module's tilt tamper functionality is designed to operate with the module installed vertically.
1. Remove the pipe bracket and band clamp from the Pipe Mount Installation Kit (Itron part number CFG0005-003).
2.
Loosen the band clamp screw until the end of the band releases.
3. Push the end of the clamp's band through the holes in the pipe bracket. The pipe bracket must be oriented
as shown below.
4. Place the band clamp around the pipe. The band will loosely wrap around the pipe.
5. Push the end of the band through the band clamp screw assembly. Turn the band clamp's screw assembly
to fit into the pipe bracket opening. Tighten the clamp screw until the band clamp is secure on the pipe.
Caution The pipe bracket must fit firmly against the pipe to prevent slippage.
Adapter Plate Mounting Positions
The following pictures show adapter plates mounted on horizontal or 45-degree angle pipes.
Caution Regardless of the pipe's direction, the adapter plate mounting lug must always be at the top.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
11
Mounting the 100G Series Gas ERT Module
If the pipe is a 45 degree angle up to the right, install the adapter plate as shown below.
Typical module mounting
Mounted adapter plate
If the pipe is a 45 degree angle up to the left, install the adapter plate as shown below.
Typical module mounting
Mounted adapter plate
If the pipe is horizontal, install the adapter plate as shown below.
Typical module mounting
Mounted adapter plate
To mount the adapter plate on the pipe bracket
Caution Vertical mounting position is important to maximize RF performance. Mount the 100G series
remote gas module with the module label arrow pointing up. The module's arrow must never point to
either side or upside down. The module tilt tamper functionality is designed to operate with the module
installed vertically.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
12
Mounting the 100G Series Gas ERT Module
1. Place the adapter plate on the pipe bracket with the mounting lug at the top or bottom. The adapter plate
screw bosses fit into the pipe bracket recess.
2. Ensure the adapter plate is positioned as shown below with the mounting lug (1) at the top or bottom. To
install the adapter plate on a vertical pipe, use the two shortest (1/2-inch) adapter plate mounting screws
from the installation kit. Place the mounting screws (2) in the holes shown below.
3. Tighten both screws securely in an alternating pattern. Tighten to 9 - 12 inch-pounds torque.
To mount the 100G series remote gas module on the adapter plate
1. Using the ERT module and the two one-inch mounting screws from the Pipe Installation kit, place the
back of the remote ERT module against the face of the adapter plate. The adapter plate mounting lug (1)
must be positioned just above the ERT module mounting lug recess (2).
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
13
Mounting the 100G Series Gas ERT Module
2. Push up on the module until the adapter plate mounting lug (1) is as far as possible inside the module
mounting lug recess (2).
3. Align the ERT module backplate mounting holes with the pipe mount adapter plate holes. Install the two
one-inch ERT module mounting screws from the installation kit.
4. Tighten the module mounting screws evenly in an alternating fashion. Tighten to 9 - 12 inch-pounds of
pressure.
To install tamper seals and cable ties
1. Place the new tamper seals from the Pipe Installation Kit over the 100G series remote gas module
mounting screws.
2. Firmly push both tamper seals all the way into place with a 1/4-inch nut driver or similar blunt tool.
Note A tamper seal is fully seated when the top of the tamper seal is approximately 1/16-inch below the
top of the screw recess.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
14
Mounting the 100G Series Gas ERT Module
3. Gather any excess ERT module cable. Loop a cable tie around the pipe and excess module cable.
4. Insert the chiseled end of the cable tie into the locking end and pull the cable tie tight. Cut off and properly
dispose the excess cable tie.
100G series remote gas module pipe mount installation is complete.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
15
Mounting the 100G Series Gas ERT Module
Mounting the Remote Gas Module on a Wall or Other Flat
Vertical Surface
Carefully select a mounting location free from electrical wires. The mounting location must have the proper
clearance to accommodate the 1-1/2-inch module mounting screws so nothing is damaged by the drill or
mounting screws.
Note For easier installation, drill three pilot holes in the mounting surface (use the correct size drill
bit to accommodate the module mounting screws [see the drilling template below]). The drilled pilot
holes for the two bottom screws must be on a horizontal line. To mount the module on a sheet metal
surface, use the mounting screws included with the Remote Mounting kit. Use a comparable wood
screw to mount the module on a vertical wood surface.
Remote module drilling template
A 3 inches
B 1-11/16 inches
C 3-3/8 inches
To mount the remote gas module on a wall or other flat vertical surface
1. Using one of the three 1-1/2-inch mounting screws from the Pipe Mount Kit, turn the mounting screw for
the mounting lug (top of module) part way into the mounting surface.
2. Place the 100G series remote gas module mounting lug recess (on the top of the module backplate) just
under the screw head.
3. Slide the module upward until the screw head fits completely inside the mounting lug recess. Several
adjustments may be necessary to properly position the screw for module mounting.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
16
Mounting the 100G Series Gas ERT Module
4. Install the bottom two mounting screws. Fasten the screws in an alternating pattern until fully tightened to
secure the module firmly in position.
To install tamper seals and cable ties
1. Place a new tamper seal (from the Pipe Installation Kit) over each ERT module mounting screw.
2. Firmly push both tamper seals into place with a 1/4-inch nut driver or similar blunt tool.
Note A tamper seal is fully seated when the top of the tamper seal is approximately 1/16-inch below the
top of the screw recess.
3. To reduce the risk of cable damage, secure the excess module cable with the cable ties from the Pipe
Mount Installation Kit. Pull the cable tight. Remove and properly dispose the excess cable tie.
100G series remote gas module installation on a vertical flat surface or wall is complete.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
17
CHAPTER 3
Rotary Meter Installation
This chapter provides the instructions to install the 100G series remote gas module on rotary gas meters.
Reference the 100G Series Remote ERT Module Meter Compatibility List on page 4 for rotary meters
compatible with the 100G series remote gas module.
GE Dresser series B3 meter
GE Dresser series LMMA rotary meter
GE Dresser series D800/D1000 meter
GE Dresser ES3
GE Dresser ETC
American rotary meter
Romet Imperial series RM meter
Romet Imperial ECM2 meter
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
18
Rotary Meter Installation
Required Installation Materials Available from Itron
The materials in the following table are required to install the remote ERT module.
Itron Part Number
ERG-500X-503
ERG-500X-503
Note this remote ERT module comes standard with 12-inch lead wires and may be
shipped directly to the meter manufacturer for a factory-installed cable (interface). The
interface cable must be purchased directly from the meter manufacturer.
Important You must purchase the interface cable directly from the meter manufacturer.
CFG-0005-003
Pipe Installation Kit
Connecting the 100G Series Gas ERT Module to the GE Dresser
Rotary Meter Cable
You may ship the Itron 100G series remote gas module directly to GE Dresser for a factory-installed cable. If
you connect the module to the meter using an existing cable purchased from GE Dresser, complete the
following cable installation procedure.
Caution The purchased cable must have a mating connector compatible to the meter receptacle.
GE Dresser cables may be wired in different configurations for specific applications. If necessary,
contact GE Dresser for wiring diagrams for your specific application.
To connect the module to the rotary meter cable
1. Remove the backplate (4 screws) from the module and expose the module lead wires. The backplate and
screws will be re-installed on the ERT module later in this procedure so store them (temporarily) in a safe,
secure place.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
19
Rotary Meter Installation
2. Insert the lead wires from the module into new 3M gel connectors (Itron part number CON-0023-001)
together with the same colored lead wire from the meter cable (see the wiring table below) and crimp
using a 3M hand-held crimping tool.
Rotary Meter to Remote ERT Module Wire Table
Rotary meter wire
Remote ERT module wire
Red
Red
White
White
Blue
Blue
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel connectors. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel connector is fully crimped (collapsed) to allow time for the low
viscosity silicone-based gel to flow (3). If the silicone gel flows out of the crimped connector, avoid
touching the gel. Gel flowing from the connector provides environmental protection for the connection.
Note Do not strip lead wire prior to inserting the wire in the gel connector.
3.
After completing the wiring connections, install a cable tie to the meter cable just below the exposed
colored lead wires on the cable insulation. Remove the excess cable tie using a hand-held side-cutter
pliers. The cable tie performs as a cable strain relief to mitigate the risk of destructive tension on the lead
wires.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
20
Rotary Meter Installation
4. Tuck the three gel connectors and cable tie inside the module housing, as shown in the following
placement schematic illustration.
5. Install the 100G series remote gas module backplate using the four screws previously removed from the
module and a Torx T-10 screwdriver.
Important Verify the cable tie and gel connectors are inside the module housing and the cable extends
out of the slot in the backplate. Torque the backplate mounting screws to 9 to 12 inch-pounds.
6. Install the module on the wall or a pipe using the Pipe Installation Kit (Itron part number CFG-0005-003).
For mounting instructions, see Mounting the 100G Series Gas ERT Module.
Connecting and Installing the GE Dresser D800/D1000 Meter
Meter manufacturers may provide ERT mounting kits and installation procedures. If GE Dresser's 100G series
to GE Dresser D800/D1000 meter installation procedure is not available, follow this procedure.
Installing the ERT module to the meter requires the following customer-supplied materials.
Requirement
Description
D800 or D1000
GE Dresser meter
ERG-500X-503
ERT modules include a cable tie for strain relief and tamper seals.
100G remote ERT module
Phillips-head screwdriver
Torx screwdriver
T-15
Screws
(1) 8-32 x 1/2"
(2) 8-32 x 3/4"
Kep® nuts
(3) 8-32"
3M UR2
3-wire gel connector
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
21
Rotary Meter Installation
To prepare the GE Dresser D800/D1000 meter for the ERT module installation
1. Loosen and remove the two screws holding the mounting brackets to the meter.
After the brackets are removed, the pulse output cable is visible.
2. Loosen the cable gland and pull the cable out until it extends 7.5 to 8" out of the cable gland.
3. Tighten the cable gland. Do not use a plier or wrench to tighten the cable gland.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
22
Rotary Meter Installation
4. Rotate one bracket. Route the meter cable through the holes located at the bend of the mounting brackets.
5. Attach the brackets to the meter using the previously removed screws.
To connect the 100G ERT module to the meter
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity
silicone-based gel to flow (3). If the silicone gel flows out of the crimped connector, avoid touching the
gel. Gel flowing from the connector provides environmental protection for the connection.
Note Connecting the D800 or D1000 to the 100G remote module requires 3M gel cap connectors. Itron
supplies the two-wire gel cap connectors. Users who want to complete three-wire connections must
supply the 3M UR2 connectors.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
23
Rotary Meter Installation
1. Splice the meter pulse output wires to the ERT module wires using gel cap connectors. Follow the wire
connections in the D800/D1000 to 100G ERT module wire connections table.
Pulse Outputs
D800/D1000 wire
Pulse output
1 only
Pulse output 1+
Brown
White and Blue
White
Pulse output 1-
Green
Red
Red
Pulse output 2+
White
White and blue
White
Pulse output 2-
Black
Red
Red
Pulse output 3+
(Fault)
Red
White
White
Pulse output 3(Fault)
Blue
Blue
Blue
Pulse Output 1 Only
Pulse output
2 only
Pulse output 2 with
fault (pulse out 3)
Pulse output 2 with fault
(pulse out 3)
Pulse Output 1 and Fault
Note See GE Dresser documentation for detailed information about pulse outputs 1 and 2. See the 100G
Series Remote ERT Module Meter Compatibility List on page 4 for pulse requirements and compatibilities.
2. After the wiring connections are completed, install the cable tie approximately 1/8" from the end of the
cable insulation as shown.
3. Position the portion of the cable with the cable tie (strain relief) into the slot on the ERT module's back
plate.
4. Carefully fold the ERT module wires into the ERT module housing. Be careful not to pinch the wires or
gel connections between the housing and the back plate.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
24
Rotary Meter Installation
5. Install the ERT module back plate using the T-15 Torx screws supplied with the ERT module.
To mount the ERT module on the D800 or D1000 meter
1. Route the cable through the channel in the backplate standoffs.
2.
Insert the 8-32 x 1/2" screw into the top hole in the meter mounting bracket and thread one of the Kep
nuts loosely onto the end of the screw.
3. Tilt the bottom of the ERT module away from the mounting bracket and slide the notched mounting hub
onto the screw and Kep nut. Do not tighten the screw.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
25
Rotary Meter Installation
4. Install the bottom two mounting screws and Kep nuts. Tighten the three mounting screws in an alternating
pattern.
5. Install the supplied red tamper seals over the bottom mounting screws on the ERT module.
Connecting and Installing the 100G Series Module to the GE
Dresser ES3 or ETC
Meter manufacturers may provide ERT mounting kits and installation procedures. If GE Dresser's 100G series
to GE Dresser ES3 or ETC device installation procedure is not available, follow this procedure.
Note You must purchase the ES3 or ETC device as AMR Ready from GE Dresser. A
successful installation requires an AMR Ready ES3 or ETC. Reference the GE Dresser
MeterWare software manual for configuration information.
To prepare the GE Dresser ES3 or ETC for the ERT module installation
1. Score (cut) the cable jacket surrounding the ES3 or ETC wires.
2. Carefully remove the cable jacket to expose the ES3 or ETC wires.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
26
Rotary Meter Installation
To connect the ES3 or ETC and 100G ERT module wires
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity
silicone-based gel to flow (3). If the silicone gel flows out of the crimped connector, avoid touching the
gel. Gel flowing from the connector provides environmental protection for the connection.
Note Connecting the ES3 or ETC to the 100G remote module requires 3M gel cap connectors. Itron
supplies the two-wire gel cap connectors. Users who want to complete three-wire connections must
supply the 3M UR2 connectors.
1. Splice the meter wires to the ERT module wires using gel cap connectors. Follow the wire connections in
the following wire connection tables.
Wire connections
Pulse Outputs
ES3/ETC Wire
Color
Pulse output 1 only
Pulse output 1 with fault (pulse output 3)
Pulse Output 1+
White
White and Blue
White
Pulse Output 1-
Black
Red
Red
Pulse Output 3+ (Fault)
Red
White
Pulse Output 3- (Fault)
Green
Blue
Pulse Output 1 Only
Pulse Output 1 and Fault
Note See the 100G Series Remote ERT Module Meter Compatibility List on page 4 for pulse requirements
and compatibilities.
Caution If alarm functionality is not required, at a minimum, you must tie the white and blue ERT module
wires together. Wiring the white and blue ERT module wires together, eliminates the possibility of the ERT
module falsely incrementing cut cable tampers.
2. Clip off the unused green, red, and shield wires from the ES3 cabling.
3. Tuck all of the wires into the module's housing.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
27
Rotary Meter Installation
4. Align the ERT module mounting holes with the ES3 or ETC bracket mounting holes. Use a T15 Torx
screwdriver to insert and tighten the mounting screws. Tighten the screws in an alternating pattern.
To confirm the correct ERT module mounting
Important Regardless of the meter orientation (side or top inlet), the 100G ERT module must always be
mounted in a vertical position with the arrow on the front label and the meter mounting bracket arrow
pointing up. Vertical positioning ensures the tilt/tamper switch in the module is in the correct position.
•
The 100G ERT module is in the correct vertical mounting position when the arrow on the front label is
pointed upward.
Configuring Index Settings Using the GE Dresser MeterWare
Software
GE Dresser MeterWare software is used to configure the ERT module's index settings.
Important This information is subject to change without notice. Refer to the GE
Dresser MeterWare product documentation to verify the most current information
about programming and configuring the corrector for use with the 100G series remote
ERT module.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
28
Rotary Meter Installation
To change ERT module index settings
1.
2.
3.
4.
Open the GE Dresser MeterWare software.
Select the LiveData tab.
Confirm the firmware version and current index settings.
If you change a variable, click Update Values to complete the change.
To view the volume configuration
1. Select the Configuration tab.
2. Confirm the volume configuration and pulse width settings.
3. Use the drop down lists to change a variable.
4. Click OK to complete the change.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
29
Rotary Meter Installation
Programming the Remote ERT Module for GE Dresser Rotary
Meters
To program 100G series remote gas modules for use with GE Dresser rotary meters, use the meter drive rates
from the drive rate table in this section.
B3, LMMA & S3A CTR/TC Meter Drive Rates for Remote ERT Module
Programming
Caution Do not use these meter drive rates to program residential direct-drive or commercial directdrive modules. Use the information in the following tables to program ERT modules connected to GE
Dresser rotary meters.
B3, LMMA, S3A CTR/TC Meter Drive Rates
B3 CTR Meter Size
B3 CTR Meter Pulse Rate
8C
10
11C
10
15C
10
2M
10
3M
10
5M
10
7M
10
11M
10
16M
100
23M
100
38M
100
56M
100
Meters built 1/99 and beyond
B3 TC Meter Size
B3 TC Meter Pulse Rate
Meters built prior to 1/99
B3 TC Meter Size
B3 TC Meter Pulse Rate
8C
10
8C
50
11C
10
11C
50
15C
10
15C
50
2M
10
2M
50
3M
10
3M
50
5M
10
5M
50
7M
10
7M
50
11M
10
11M
50
16M
100
16M
500
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
30
Rotary Meter Installation
LMMA CTR Meter
Size
LMMA CTR Meter Pulse
Rate
LMMA TC Meter Size
LMMA TC Meter Pulse Rate
1.5M
10
1.5M
10
3M
10
3M
10
5M
10
5M
10
7M
10
7M
10
11M
10
11M
10
16M
100
16M
100
23M
100
38M
100
568CM
100
102M
100
S3A CTR Meter Size
S3A CTR Meter Pulse Rate
S3A TC Meter Size
S3A TC Meter Pulse Rate
1.5M
10
1.5M
10
3M
10
3M
10
5M
10
5M
10
7M
10
7M
10
11M
10
11M
10
16M
100
16M
100
Connecting the Remote ERT Module to the Romet Electronically
Compensated Meter (ECM2®)
The Romet ECM2® meter has three Form "A" outputs that can be configured at the factory to provide any
combination of the following three outputs:
•
•
•
Uncorrected volume (UNC VOL)
Corrected volume (COR VOL)
Alarm
The pulse weight for the volumetric outputs is configured in SetUp Mode at Menu items > SET UNC OUT
and Menu items > SET COR OUT. Since Setup Mode is fully configurable, the ECM2® module is
universally adaptable to all Romet TC meter bodies. Reference the Romet technical manual for specific details
on the ECM2®.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
31
Rotary Meter Installation
Wiring the 100G Series Gas ERT Module to the Romet ECM2®
Meter
Connect the correct interface wirings and set the output pulse spacing to complete 100G series remote gas
module installation with the Romet ECM2® meter. See the ECM2® interface wiring table below to complete
wire connections.
Function
(+)UC
(-)UC
(+)CC
(-)CC
(+)ALM
(-)ALM
(+)Aux.CC
(-)Aux.CC
ERT Module wire
White and
Blue
Red
White and
Blue
Red
White and
Blue
Red
White and
Blue
Red
34-125-20
34-125-40
Pin location
for Cannon 34-125-41
Connector 34-125-42
Part
34-125-43
Number
34-125-44
34-125-45
34-125-50
34-125-51
Caution Set the ECM2® output pulse spacing to 750ms for operation with the 100G series remote gas
module. Output spacing represents an off-time between pulses.
Mounting the 100G Series Gas ERT Module
Select an appropriate mounting location on adjacent piping close to the meter. Using the pipe bracket,
mounting plate and band clamps from the Pipe Installation Kit (Itron part number CFG-0005-003), secure the
100G series remote gas module. Use the cable ties from the kit to secure any excess wire to the piping (see
Mounting the Remote ERT Module a Pipe on page 10).
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
32
Rotary Meter Installation
Romet ECM2/100G Series Gas ERT Module Mounting Option
This mounting procedure requires the Romet ECM2/ERT Mounting Kit (Romet part number 34-444-1-KIT).
To mount the 100G series remote gas module on the Romet ECM2 meter
1. Remove the module screw from the back of the ECM2 meter and discard.
2. Insert the mounting screw fitted with the three lock washers. Two lock washers are used as spacers as
shown.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
33
Rotary Meter Installation
3. Attach the mounting plate to the meter. Insert the mounting screw where the module screw was removed.
Torque the mounting screw to 5-7 ft.lbs. to secure the plate to the Romet meter.
4. Mount the 100G series remote gas module using the pre-drilled holes on the mounting plate and the
module mounting screws.
5. Place new tamper seals over the two screws. Press tamper seals into place using an 11/32-inch nut driver
or similar blunt tool.
6. Connect the module to the meter using the previously installed cable interface.
Installing the Remote ERT Module to the Elster American Meter
RPM Series Rotary Meter
Some meter manufacturers provide ERT mounting kits and installation procedures for their meters. If 100G
series remote gas module to Elster American RPM meter installation instructions are not available, follow the
installation procedure in this section.
Elster American Meter RPM Series Rotary Meter
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
34
Rotary Meter Installation
To install the 100G series remote gas module on an Elster American RPM series meter
1. Remove the meter's top plate by removing the two 5mm screws and carefully prying up on the plate. The
plate is secured with an o-ring seal. Remove the O-ring from the plate.
Caution If the O-ring is damaged during removal, obtain a replacement from Elster American Meter Co.
2. Look into the meter tower and find the meter switch lead and connector (4-pin).
3. If the lead and connector are not visible or cannot be found, remove the four 5mm mounting screws and
the register cover. The meter switch lead and connector will be visible inside the cover.
4. Feed the lead and connector into the register cover tower.
Note Save any meter tags. You will re-install them later in the installation process.
5. If you removed the register cover, replace the cover using the four (4) 5mm mounting screws.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
35
Rotary Meter Installation
6. Attach the 4-pin male connector on the Elster American Meter adapter plate to the 4-pin female connector
inside the meter's tower. The connectors will slide together and latch.
7. Carefully push the connectors and wires into the meter tower housing.
8. Lubricate the O-ring with O-ring lubricant and install the O-ring on the adapter plate. Insert the adapter
plate into the tower and tighten the two 5 mm screws.
To connect the manufacturer cable to the ERT module
Note Connection to an Elster American Meter requires a cable interface compatible to an Elster
American Meter RPM rotary meter.
1. Trim the ERT module wires to 3.5 inches.
2. Carefully strip the insulation covering from the meter cable (purchased from the meter manufacturer)
approximately 1-1/2-inches from the end.
Caution Do not cut through the individual wire insulation.
3. Separate the meter cable's black, white, and red wires for connection to the 100G series remote gas
module. Cut off the unused wires even with the outer covering (insulation).
Caution Do not strip the individual wires.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
36
Rotary Meter Installation
4. Connect the meter cable to the 100G series remote gas module using 3M gel-cap connectors. Follow the
wire connection table and wiring diagrams below. See Installation Prerequisites on page 7 for appropriate
3M crimping tools.
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity
silicone-based gel to flow. If the silicone gel flows out of the crimped connector, avoid touching the gel.
Gel flowing from the connector provides environmental protection for the connection.
American RPM Meter to the 100G series remote gas module Wire Connections
American RPM Meter wire
ERT module wire
Black
Blue
White
White
Red
Red
5. Insert the meter cable through the slot on the ERT module backplate. Install a cable tie to the meter cable
wire below the meter cable insulation to provide strain relief.
6. Tuck the connectors and cable tie into the ERT module housing. Place backplate on the assembly and
tighten the four backplate screws using a size T-10 Torx screwdriver.
Important Verify the cable tie and gel connectors are inside the module housing and the cable extends
out of the slot in the backplate. Torque the backplate mounting screws to 9-12 inch-pounds.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
37
Rotary Meter Installation
To install the 100G series remote gas module cable
1. Insert the plug on the cable connected to the ERT module into the receptacle on the meter adapter plate.
2. Tighten the threaded collar on the plug onto the American Meter interface receptacle. Verify the
connection is hand-tight.
Programming the Remote ERT Module
Caution You must program the 100G series remote gas module before use.
Program the 100G, 100G DL, 100G DLN, and 100G DLT ERT modules using:
•
•
•
An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher
or
A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or
higher or
A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
The 100G DLS ERT modules support enhanced security with the Itron Security Manager. Enabling command
or enhanced security requires additional programming.
Program the 100G DLS ERT modules using:
•
•
•
An FC200SR handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher
or
An FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 3.3
or higher or
A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 3.3 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
38
Rotary Meter Installation
To enable enhanced security and for more complete programming information, see the Field Deployment
Manager Endpoint Tools Mobile Application Guide (TDC-0934).
FC200SR
FC300 with SRead
900MHz Belt Clip Radio
To program the remote ERT module
•
•
•
Program the meter drive rate into the 100G series remote gas module using a handheld computer or Belt
Clip Radio and laptop computer.
For all programming and Check Endpoint operations using a handheld computer, hold the handheld as
close to vertical as possible. For best success, keep the handheld within six feet of the target ERT module.
Verify you have the correct programming mode (fixed network mode, mobile high power mode,
mobile/handheld mode, or hard-to-read mobile/handheld mode) for your application.
Programming parameters are based on the configuration file loaded into the programming device. During
programming, the 100G series remote gas module is set to the nearest 100 cubic feet; the last two digits (tens
and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read
to the nearest cubic foot.
•
Read or Check the 100G series remote gas module using the handheld computer or Belt Clip Radio.
• If the read result is higher than the number programmed in step 1, the 100G series remote gas module
is counting correctly.
• If the read result is not higher than the number programmed in step 1, replace the 100G series remote
gas module.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
39
Rotary Meter Installation
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
40
CHAPTER 4
Electronic Instrument Installation
This section provides the instructions to install the 100G series remote gas module on:
•
•
•
•
•
•
Honeywell Instruments Mini-P, Mini-AT, Mini-Max, and EC-AT volume correctors
Honeywell Instruments Temperature Compensated Indexes (TCI)
GE Dresser IMC/W2 and MC2 Micro Correctors
Galvanic Gas Micro volume Corrector
Eagle Research MP plus volume corrector
Romet AdEM® volume corrector
Mini-AT
IMC/W2
XARTU-1
Mini-Max
MC2
EC-AT
TCI
Gas Micro
MPplus
AdEM
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
41
Electronic Instrument Installation
Installation Prerequisites
100G series remote gas module installation to a volume corrector or instrument requires:
•
•
•
100G series remote gas module ERT module compatible to a volume corrector or instrument (see the
100G Series Remote ERT Module Meter Compatibility List on page 4).
Volume corrector or instrument compatible with the remote ERT module.
Proper tools and devices for installation and programming (see Installation Prerequisites on page 7).
Installation Overview
Installing the 100G series remote gas module to a volume corrector or instrument involves five tasks:
1. Programming the volume corrector or instrument. See the manufacturer's documentation for specific
corrector or instrument parameters.
2. Installing corrector or instrument manufacturer retrofit parts (if necessary).
3. Attaching the ERT module to a pipe or vertical flat surface (wall) (see Mounting the 100G series remote
gas module on page 9).
4. Connecting the ERT module to the volume corrector or instrument (see To wire the 100G series remote
gas module to the Honeywell Instrument on page 43), Honeywell Instrument Temperature Compensating
Index (TCI), GE Dresser Micro Corrector (IMC/W2 or MC2), Galvanic Gas MPplus Micro Corrector, or
Eagle Research MPplus corrector.
5. Programming the 100G series remote gas module (see Programming the Remote ERT Module on page
38).
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
42
Electronic Instrument Installation
Programming the Honeywell Instrument Parameters
Item Code Settings
Channel A
Corrected
Volume
Channel B
Uncorrected
Volume
Channel C
Pulse Output Spacing
#58
Instrument
Pulse Output Options
#56
#93
#57
#94
#95
#115
ECAT
Pulse Board Ver-2(3)
Form-A
Cor Vol
Unc Vol 2
Cor
Vol
Cor
Vol
1 = 1.0 sec
2 = 2.0 sec
or
4 = 0.5 sec
Pulse Board Ver-3(2)
Form-C1 Form-A
Main Board Type-2*
Mini with
Form A Main
board
Cor Vol
Mini-AT
JB29, JB30 & JB31
Jumpered for Form-A*
Cor Vol
Unc Vol
Mini-Max
All main boards
Cor Vol
Unc Vol
#1014
#1015
Terminal Board Connections/Wiring
Red ERT wire goes to K
Blue and White ERT wires go to Y
Connection must be on same terminal board channel
(for example, Ka/Ya; kb/Yb; Kc/Yc)
Ka, Ya = Channel A
Kb, Yb = Channel B
Kc, Yc = Channel C
1 = 1.0 sec
or
2 = 2.0 sec
Channel A
TCI
Form A main board
Cor Vol
Cor Vol
Itron
100G
Itron
100G
ERT
TCI
White
Orange and Brown
Red
Yellow
Blue
Blue (Alarm)
Channel B
ERT
TCI
White and Blue
White
Red
Green
Module does not support Form-C pulse output board.
100G modules do not support 8 digits (0 blank) configurations (Item #96 and Item #97)
*For optional SPA Board, jumper must be installed on J1-B as indicated in the Mercury Quick Reference
Guide (page 148) for Form A.
IItem #90 is used to set unit of measure for corrected volume.
Item #92 is used to set unit of measure for uncorrected volume.
Item #98 is used to set drive rate for the corrector. Should be the same as the plate above the uncorrected dials
and the same as the plate on the index drive of the meter.
TDC-0824-014 100G Series Gas ERT Module Installation Guide, Remote Mount
Proprietary and Confidential
43

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : TDC-0824-014
Create Date                     : 2017:03:09 07:47:21-06:00
Modify Date                     : 2017:03:27 20:27:26-07:00
Subject                         : Natural Gas Solutions
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Metadata Date                   : 2017:03:27 20:27:26-07:00
Creator Tool                    : Acrobat PDFMaker 11 for Word
Format                          : application/pdf
Title                           : 100G Series Gas ERT Module Installation Guide, Remote Mount
Description                     : Natural Gas Solutions
Creator                         : TDC-0824-014
Document ID                     : uuid:752bbf3e-813e-4964-9743-56d2713a0c3a
Instance ID                     : uuid:d6219b28-2840-42fb-af7e-b5cd009c9c5d
Producer                        : Adobe PDF Library 11.0
Comments                        : Proprietary and Confidential
Company                         : Itron
Source Modified                 : D:20160624125812
Page Count                      : 51
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EWQ100GDLRS

Navigation menu