Itron 24GZB Automatic Meter Reading Device for Gas Meters User Manual 2 4GZ OpenWay Gas Module Installation Guide

Itron, Inc. Automatic Meter Reading Device for Gas Meters 2 4GZ OpenWay Gas Module Installation Guide

Contents

Users Manual Part 3

Download: Itron 24GZB Automatic Meter Reading Device for Gas Meters User Manual 2 4GZ OpenWay Gas Module Installation Guide
Mirror Download [FCC.gov]Itron 24GZB Automatic Meter Reading Device for Gas Meters User Manual 2 4GZ OpenWay Gas Module Installation Guide
Document ID1062739
Application IDvi9lc3Z1YfZ1N2KciVfewQ==
Document DescriptionUsers Manual Part 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize165.9kB (2073696 bits)
Date Submitted2009-01-29 00:00:00
Date Available2009-02-02 00:00:00
Creation Date2009-01-16 14:48:25
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2009-01-16 14:50:46
Document Title2.4GZ OpenWay Gas Module Installation Guide
Document CreatorAcrobat PDFMaker 7.0.7 for Word

Installing the 2.4GZ OpenWay Gas Module
4. Place a new tamper seal over two of the mounting screws as shown below.
2.4GZ OpenWay Gas Module Installation Guide
33
Chapter 3 Sensus Meter Installation
5. Press the new tamper seals into place using the 11/32-inch nut driver (or another
similar blunt tool).
6. Complete any necessary paperwork. Make sure no excess material is left on the
customer premises.
The OpenWay Gas Module is now installed on the meter.
34
2.4GZ OpenWay Gas Module Installation Guide
Installing the 2.4GZ OpenWay Gas Module
Waking Up the 2.4GZ OpenWay Gas Module
You can use an Itron magnet (part number MSE-0159-003) to wake up the 2.4GZ
OpenWay Gas Module.
To wake up the 2.4GZ OpenWay Gas Module
1. Place the magnet under the index cover with the arrow on the magnet pointing up
toward the cover.
2. Slide the magnet back toward the 2.4GZ OpenWay Gas Module backplate until it is
within a 1/4-inch of the backplate.
3. Hold the magnet there for five seconds to wake up the 2.4GZ OpenWay Gas Module.
2.4GZ OpenWay Gas Module Installation Guide
35
Chapter 3 Sensus Meter Installation
36
2.4GZ OpenWay Gas Module Installation Guide
CHAPTER 4
Actaris Meter Installation
This chapter shows you how to install a 2.4GZ OpenWay Gas Module on an Actaris meter.
Actaris meters are also known by the names: Sprague, and
Schlumberger. For consistency, all of these meter types will be referred
to as Actaris meters for this installation procedure.
Before installing the 2.4GZ OpenWay Gas Module, verify that you have:
•
A compatible meter shown in the Meter Compatibility List.
•
A compatible index. Itron 2.4GZ OpenWay Gas Modules can be used with standard
dial and direct read (odometer) indexes.
•
The list of materials defined under Installation Prerequisites in this chapter.
Installation Prerequisites
The following items are required to install the Itron 2.4GZ OpenWay Gas Module.
Materials Supplied By Itron
The following items are supplied by Itron:
•
2.4GZ OpenWay Gas Modules
•
New tamper seals
Materials Supplied By You
You must supply the following items to install, initialize, and check the 2.4GZ OpenWay
Gas Module on the meter.
2.4GZ OpenWay Gas Module Installation Guide
37
Chapter 4 Actaris Meter Installation
•
Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten
index and index-cover screws.
•
Side-cutting plier/wire snips Used for cutting wire seals, if necessary.
•
Small putty knife Used to remove all traces of old gaskets from the meter.
•
Meter seals, wire seals, and seal press Used to secure the meter from tampering, if
necessary.
•
11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs
over screw holes.
•
Replacement screws Used to mount 2.4GZ OpenWay Gas Module assembly to
meter and index to module assembly backplates.
•
FC200SR with EndPoint-Link or EndPoint-Link Pro software Used to program
and check ERT assembly.
Replacement Screws
Replacement screws used in this procedure are shown below.
For mounting 2.4GZ OpenWay Gas Module assemblies on meters:
•
Use 10 - 24 x5/8-inch slotted, Fillister head screws.
For mounting indexes on 2.4GZ OpenWay Gas Module backplates:
•
Use 10 - 24 x 1/4-inch slotted, round head screws.
Preinstallation Preparations
Before installing the 2.4GZ OpenWay Gas Module on a meter, verify that:
•
All Itron gas modules are 2.4GZ OpenWay Gas Modules for your brand of gas
meters.
•
The model numbers of all meters on which the 2.4GZ OpenWay Gas Modules will be
installed are included in the Meter Compatibility List.
Installing the 2.4GZ OpenWay Gas Module
There are four major steps to installing the 2.4GZ OpenWay Gas Module on a meter:
•
Remove the index
•
Assemble the 2.4GZ OpenWay Gas Module
•
Program the 2.4GZ OpenWay Gas Module
•
Attach the 2.4GZ OpenWay Gas Module to the meter.
NOTE Properly dispose of all unused screws, old index covers, gaskets, tamper
seals, and other left-over materials. Do not leave any materials on customer
premises.
38
2.4GZ OpenWay Gas Module Installation Guide
Installing the 2.4GZ OpenWay Gas Module
Remove the Index
The first major step when installing a 2.4GZ OpenWay Gas Module on a meter is to remove
the index from the meter.
To remove the index
1. Remove tamper seals from the meter.
2. Remove and keep the cover screws.
3. Remove the index cover from the meter.
4. Check the screws for length and corrosion. If they are 5/8 inches long and not
corroded, you can use them to attach the 2.4GZ OpenWay Gas Module to the meter.
If the screws are not the correct length, or are corroded, dispose of them properly.
Replace them with the screws listed in Replacement Screws on page 38.
5. Use the index cover just removed as a temporary storage location for screws.
NOTE Dispose of the index cover properly when finished with the installation
procedure. Do not leave it on customer premises.
6. Loosen the index mounting screws one-half turn.
2.4GZ OpenWay Gas Module Installation Guide
39
Chapter 4 Actaris Meter Installation
7. Slide the index up off its mounting screws and remove it from the meter. Set the index
where it won't get damaged or dirty.
8. Remove the index mounting screws from the meter. Check the screws for length and
corrosion. If they are 1/4 inches long and not corroded, you can use them to attach the
index to the 2.4GZ OpenWay Gas Module.
If the screws are not the correct length, or are corroded, dispose of them properly.
Replace them with the screws listed in Replacement Screws on page 38.
9. Remove all traces of the old index gasket from the meter. The new 2.4GZ OpenWay
Gas Module has its own gasket.
10. Dispose of the old gasket properly and do not leave it on the customer premises.
Assemble the 2.4GZ OpenWay Gas Module
When installing a 2.4GZ OpenWay Gas Module, the next major step is to create the
endpoint module assembly by combining the endpoint backplate and cover with the meter
index.
40
2.4GZ OpenWay Gas Module Installation Guide
Installing the 2.4GZ OpenWay Gas Module
To separate the cover from the backplate
1. Obtain a new 2.4GZ OpenWay Gas Module.
2. Place your thumb in the notch on the bottom of the endpoint to hold the backplate and
pull the cover away from the backplate.
You can also separate the cover from the backplate by gently pulling on the wriggler
until the backplate comes free.
3.
Set the cover aside where it won't be damaged.
4. Put the index mounting screws about two turns into the backplate index mounting
posts.
2.4GZ OpenWay Gas Module Installation Guide
41
Chapter 4 Actaris Meter Installation
5. Position the backplate and index wrigglers as shown below.
6. Slide the index mounting brackets onto the mounting screws.
7. Make sure the backplate wriggler post is below the index wriggler when lowering the
index mounting brackets onto the index mounting screws.
42
2.4GZ OpenWay Gas Module Installation Guide
Installing the 2.4GZ OpenWay Gas Module
8. Hold the index in place with your thumb and tighten the index mounting screws.
9. Slide the cover over the index and onto the backplate until it is against the gasket.
Program the OpenWay Gas Module
Once the OpenWay Gas Module has been assembled, the module must be programmed
using FieldPro on a laptop with a ZigBee dongle. Refer to FieldPro documentation for
programming information.
IMPORTANT You must perform the following programming procedure for
the OpenWay Gas Module to function properly.
When programming the OpenWay Gas Module, you must take note of the drive rate shown
on the index of Actaris meters.
2.4GZ OpenWay Gas Module Installation Guide
43
Chapter 4 Actaris Meter Installation
To Program the OpenWay Gas Module
1. Make sure the 2.4GZ OpenWay Gas Module is within 10 feet of the programming
device.
2. Verify that the programming software is running.
3. Verify that red LED on ZigBee dongle is on.
4. Hold the magnet under the 2.4GZ OpenWay Gas Module for 5 seconds and then
remove it. You will see three red blinks from the LED. This signifies that the 2.4GZ
OpenWay Gas Module is searching for a programming device. Within a few seconds
the red LED will blink five more times. The programming device will indicate
programming success or failure.
a) If five red LED blinks are not seen on the 2.4GZ OpenWay Gas Module, hold the
magnet under 2.4GZ OpenWay Gas Module for 5 seconds.
b) If 5 red LED blinks are seen on the 2.4GZ OpenWay Gas Module, but the
programming device indicates that programming failed, verify the following (1)
2.4GZ is within 10 foot range of programming device and (2) programming
software is using correct security key. Repeat holding magnet under 2.4GZ for 5
seconds.
When the 2.4GZ OpenWay Gas Module has been programmed to normal mode, it is ready
to commission to an OpenWay CENTRON meter. If an OpenWay CENTRON meter is
within range of the 2.4GZ OpenWay Gas Module, the red LED on the 2.4GZ OpenWay Gas
Module will blink three times, indicating that it is looking for all available OpenWay
CENTRON meters.
After choosing the OpenWay CENTRON meter with the best signal, the 2.4GZ OpenWay
Gas Module will blink five times to indicate successful commissioning to the meter. The
timing for this could be as quick as one second after being programmed. If within two
minutes of successful programming, the five blinks are not seen, make note of the
installation for further investigation.
NOTE Itron will be moving to this programming solution in 2008
1. Using the FC200 and Belt Clip radio, program the reading of the index that was on the
meter into the OpenWay Gas Module assembly.
During programming, the OpenWay Gas Module is programmed to the nearest 100
cubic feet; the last two digits (the tens and units) are programmed as zeros (0). Once
programming is complete, however, the OpenWay Gas Module assembly can be read
to the nearest cubic foot.
2. Slowly turn the OpenWay Gas Module drive wriggler two turns in the direction
indicated on the index drive rate. This lets you verify the module is counting properly
after assembly.
44
2.4GZ OpenWay Gas Module Installation Guide
Installing the 2.4GZ OpenWay Gas Module
IMPORTANT Do not turn the drive wriggler faster than one turn per second.
3. Read the OpenWay Gas Module assembly using the FC200 and Belt Clip radio.
Consult the EndPoint-Link Programming Guide or other applicable instructions for
details on how to read an OpenWay Gas Module.
•
If this reading is higher than the one you programmed in step 1 above, the
module assembly is counting correctly.
If the OpenWay Gas Module assembly reading is not higher than what was programmed in
step 1, replace the module with a new one.
2.4GZ OpenWay Gas Module Installation Guide
45
Chapter 4 Actaris Meter Installation
Attach the 2.4GZ OpenWay Gas Module to the Meter
After the endpoint has been programmed and is reading correctly, it must be attached to the
meter. Follow the steps below to do this.
To attach the 2.4GZ OpenWay Gas Module to the meter
1. Turn the white wriggler so one of its four drive slots lines up with the drive dog.
2. Gently place the 2.4GZ OpenWay Gas Module on the meter.
If there is a gap between the gasket and the meter, it is probably because the drive slot
of the ERT module assembly's wriggler is not properly aligned with the meter
wriggler drive dog. To correct this, remove the assembly and repeat the alignment
procedure in step one.
46
2.4GZ OpenWay Gas Module Installation Guide
Installing the 2.4GZ OpenWay Gas Module
WARNING! If there is a gap between the gasket and the meter, it is
probably because the drive slot of the ERT module assembly's wriggler is
not properly aligned with the meter wriggler drive dog. To correct this,
remove the assembly and repeat the alignment procedure in step one.
Failure to place the drive post into the drive slot can cause binding and lead
to poor registration or meter failure.
3. Turn each screw 1/4 to 1/2 turn after it contacts the cover.
IMPORTANT Meter manufacturers should torque the mounting screws 15 to 20
inch-pounds.
Only two screws are required to mount the 2.4GZ OpenWay Gas
Module. Dispose of the extra screw properly. Do not leave it on the
customer premises.
2.4GZ OpenWay Gas Module Installation Guide
47
Chapter 4 Actaris Meter Installation
4. Press new tamper seals into place with an 11/32 nut driver, or other blunt tool.
Attaching the 2.4GZ OpenWay Gas Module to Flat-faced
Model 1A Meters
If you want to install a 2.4GZ OpenWay Gas Module on a flat-faced model 1A meter you
will have to use the CFG-0015-001 adapter kit. Obtain the kit from Itron then use the
following procedure to install the kit and the 2.4GZ OpenWay Gas Module.
1. Make sure you have all of the following items in the kit.
2. Remove the drive dog from the meter and replace it with the one from the kit.
IMPORTANT Do not use a tool to install or tighten the new drive
dog, hand tighten only.
48
2.4GZ OpenWay Gas Module Installation Guide
Installing the 2.4GZ OpenWay Gas Module
3. Attach Adapter Shim Plate to the meter, as shown, using the two index mounting
screws from the kit. Apply 15 to 20 inch-pounds of torque to the screws to provide a
tight seal between the shim plate and the meter.
2.4GZ OpenWay Gas Module Installation Guide
49
Chapter 4 Actaris Meter Installation
4. Turn the white wriggler so one of its four drive slots lines up with the drive dog.
5. Gently place the 2.4GZ OpenWay Gas Module on the meter.
If there is a gap between the gasket and the meter, it is probably because the drive slot
of the ERT module assembly's wriggler is not properly aligned with the meter
wriggler drive dog. To correct this, remove the assembly and repeat the alignment
procedure in step one.
50
2.4GZ OpenWay Gas Module Installation Guide
Installing the 2.4GZ OpenWay Gas Module
WARNING! If there is a gap between the gasket and the meter, it is
probably because the drive slot of the ERT module assembly's wriggler is
not properly aligned with the meter wriggler drive dog. To correct this,
remove the assembly and repeat the alignment procedure in step one.
Failure to place the drive post into the drive slot can cause binding and lead
to poor registration or meter failure.
6. Turn each screw 1/4 to 1/2 turn after it contacts the cover.
IMPORTANT Meter manufacturers should torque the mounting screws 15 to 20
inch-pounds.
Only two screws are required to mount the 2.4GZ OpenWay Gas
Module. Dispose of the extra screw properly. Do not leave it on the
customer premises.
2.4GZ OpenWay Gas Module Installation Guide
51
Chapter 4 Actaris Meter Installation
7. Press new tamper seals into place with an 11/32 nut driver, or other blunt tool.
Waking Up the 2.4GZ OpenWay Gas Module
You can use an Itron magnet (part number MSE-0159-003) to wake up the 2.4GZ
OpenWay Gas Module.
To wake up the 2.4GZ OpenWay Gas Module
1. Place the magnet under the index cover with the arrow on the magnet pointing up
toward the cover.
2. Slide the magnet back toward the 2.4GZ OpenWay Gas Module backplate until it is
within a 1/4-inch of the backplate.
3. Hold the magnet there for five seconds to wake up the 2.4GZ OpenWay Gas Module.
52
2.4GZ OpenWay Gas Module Installation Guide

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Modify Date                     : 2009:01:16 14:50:46-06:00
Create Date                     : 2009:01:16 14:48:25-06:00
Metadata Date                   : 2009:01:16 14:50:46-06:00
Creator Tool                    : Acrobat PDFMaker 7.0.7 for Word
Format                          : application/pdf
Title                           : 2.4GZ OpenWay Gas Module Installation Guide
Description                     : Natural Gas Solutions
Creator                         : 
Document ID                     : uuid:b612da2c-6cfc-4bea-b7ca-005ab3474ae3
Instance ID                     : uuid:a9a1d218-5cc4-4f68-ac10-edc0214032ce
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Page Count                      : 20
Author                          : 
Subject                         : Natural Gas Solutions
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EO924GZB

Navigation menu