Itron 24GZRB AMR transceiver device for utility meters. User Manual Part1

Itron, Inc. AMR transceiver device for utility meters. Users Manual Part1

Contents

Users Manual Part1

Download: Itron 24GZRB AMR transceiver device for utility meters. User Manual Part1
Mirror Download [FCC.gov]Itron 24GZRB AMR transceiver device for utility meters. User Manual Part1
Document ID1363073
Application IDIkjO3OVEDpXB9HxQd2aGCw==
Document DescriptionUsers Manual Part1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize222.92kB (2786450 bits)
Date Submitted2010-10-19 00:00:00
Date Available2010-10-20 00:00:00
Creation Date2010-09-20 07:05:06
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2010-09-20 07:05:30
Document TitleUsers Manual Part1
Document CreatorMicrosoft® Office Word 2007

Natural Gas Solutions
2.4GZ OpenWay Gas Module Installation
Guide - Remote Mount
TDC-0838-001
Identification
2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
09/17/2010 TDC-0838-001
2.4GZ OpenWay Gas Module part numbers: OWG-5001-501, OWG-5001-502, OWG-5001-503, OWG-5001-504
OWG-5002-501, OWG-5002-502, OWG-5002-503, OWG-5002-504
Copyright
© 2010 Itron, Inc. All rights reserved.
Confidentiality Notice
The information contained herein is proprietary and confidential and is provided subject to the condition that (i) it is held in confidence except to the extent required otherwise by law and (ii) it is
used only for the purposes described herein. Any third party given access to this information is similarly bound in writing.
Trademark Notice
Itron is a registered trademark of Itron, Inc.
All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.
Safety Approvals
Intrinsically safe per UL Class I, Division 1, Groups C & D
Applicable Patents
U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700
Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118
Compliance Statement
This device complies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to
the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference that may cause undesirable operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.
Compliance Statement
This equipment has been tested and found to comply with the limits, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. Operation is subject to the following conditions:
• This device may not cause interference.
• This device must accept any interference that may cause undesired operation of the device.
Compliance Statement
This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules.
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Transportation Classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 2.4GZ OpenWay remote mount gas module is considered an
operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation.
Modifications and Repairs
To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's authority to
operate the equipment.
Meter Installation/Removal
In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
Warning To prevent ignition of flammable or combustible atmospheres, read, understand, and
follow the manufacturer’s live maintenance procedures.
Warning Follow these procedures to avoid injury to yourself or others:
The lithium battery may cause a fire or chemical burn if it is not disposed of properly.
Do not recharge, disassemble, heat above 100º Celsius (212º Fahrenheit), crush,
expose to water, or incinerate the lithium battery. Fire, explosion, and severe burn
hazard.
Keep the lithium battery away from children.
Warning Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to
do so by others might void any maintenance contract with your company. Unauthorized service
personnel might also be subject to shock hazard on some Itron equipment if removal of protective
covers is attempted.
Warning Substitution of components may impair intrinsic safety.
Suggestions
If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com
If you have questions or comments about the software or hardware product, contact Itron Technical Support:
Contact
Internet: www.itron.com
E-mail: support@itron.com
Phone: 1 877 487 6602
Contents
Before You Begin ......................................................................................................... iv
Document Conventions ............................................................................................................ iv
Chapter 1 2.4GZ OpenWay Remote Mount Gas Module Installation ........................ 1
Transmission Modes ...........................................................................................................................1
Programming Modes ...........................................................................................................................2
Specifications ......................................................................................................................................3
Related Documents .............................................................................................................................3
2.4GZ OpenWay Remote Mount Gas Module Meter Compatibility List..............................................3
Installation Prerequisites .....................................................................................................................7
Chapter 2 Mounting the 2.4GZ OpenWay Remote Mount Gas Module .................... 8
Installation Options ..............................................................................................................................8
Mounting Screw Specifications ............................................................................................................8
Mounting Installation Considerations ..................................................................................................9
Mounting the 2.4GZ OpenWay Remote Mount Gas Module on a Pipe ............................................10
Mounting the Endpoint on a Wall or Other Flat Vertical Surface ..................................16
Chapter 3 Rotary Meter Installation .......................................................................... 19
Required Installation Materials Available from Itron ..........................................................................20
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to the Rotary Meter Cable ...............20
®
Programming 2.4GZ OpenWay Remote Mount Gas Module for Dresser ROOTS Rotary Meters .24
B3, LMMA & S3A CTR/TC Meter Pulse Rates for Remote Module Programming ...........................24
Installing the 2.4GZ OpenWay Remote Mount Gas Module to the Elster American Meter RPM
Series Rotary Meter ................................................................................................................25
Mounting the 2.4GZ Remote Mount Module .....................................................................................30
Installing the 2.4GZ OpenWay Remote Mount Gas Module to the Romet Electronically
®
Compensated Meter (ECM2 ) ................................................................................................30
®
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to the Romet ECM2 Meter ............31
Romet ECM2 Mounting Requirement .....................................................................................31
Programming the 2.4GZ OpenWay Remote Mount Gas Module Assembly .....................................34
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
ii
Contents
Chapter 4 Electronic Instrument Installation ........................................................... 36
Installation Prerequisites ...................................................................................................................37
Installation Overview .........................................................................................................................37
Programming the Mercury Instrument ...............................................................................................38
Code Settings..........................................................................................................................38
Wiring the 2.4GZ OpenWay Remote Mount Gas Module to the Mercury Instrument.......................40
Wiring Dual Endpoints to a Mercury Instrument Corrector ...............................................................42
Required Tools .......................................................................................................................42
Wiring the Remote Module to the Mercury TCI .................................................................................44
Connecting the 2.4GZ Remote Gas Module to the Dresser ROOTS® IMC/W2 or MC2 Cable .......48
®
Installing the Endpoint to the Dresser ROOTS Micro Corrector (IMC/W2 or MC2) ........................51
Programming the 2.4GZ OpenWay Remote Mount Gas Module Assembly.....................................55
Chapter 5 Diaphragm Meter Installation ................................................................... 57
Tools and Materials Supplied By You ...............................................................................................57
Materials Available from Itron ............................................................................................................58
Replacement Gaskets .............................................................................................................58
Installing the 2.4GZ OpenWay Remote Mount Gas Module .............................................................59
Installing 2.4GZ OpenWay OpenWay Remote Mount Gas Module Encoders .................................60
Programming the OpenWay Remote Mount Gas Module Assembly ................................................69
Chapter 6 Curb Diaphragm Meter Installation .......................................................... 71
Materials Available from Itron ............................................................................................................71
Tools and Materials Supplied By You ...............................................................................................72
Installing the 2.4GZ Remote Mount Gas Module on the Curb Meter ................................................73
Programming the 2.4GZ OpenWay OpenWay Remote Mount Gas Module Assembly....................81
Chapter 7 Dattus Meter Installation .......................................................................... 83
Installation Prerequisites ...................................................................................................................83
Programming the Dattus Meter .........................................................................................................83
Installation Overview ..........................................................................................................................84
Installing the 2.4GZ Remote Mount Gas Module to Itron Dattus Meters ..........................................84
Direct Mounting the 2.4GZ OpenWay Remote Mount Gas Module to the Dattus Meter ..................85
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to a Dattus meter ............................86
Mounting the 2.4GZ OpenWay Remote Mount Gas Module .............................................................87
Programming the 2.4GZ OpenWay Remote Mount Gas Module Assembly .....................................87
Chapter 8 Sensus Sonix Meter Installation .............................................................. 90
Programming the Sensus Sonix Meter .............................................................................................90
Adjusting the Pulse Output for Sonix 600 and 880 Meters ................................................................90
Installing the 2.4GZ OpenWay Remote Mount Gas Module with Sensus Sonix Meters ...................91
Sensus Sonix2000 Pulse Output Wiring ............................................................................................91
Direct Mounting the 2.4GZ OpenWay Remote Mount Gas Module to the Sonix Meter ....................92
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to a
Sensus Sonix 600 or 880 Meter ..............................................................................................93
Programming the 2.4GZ OpenWay Remote Mount Gas Module Assembly .....................................94
Index ............................................................................................................................. 96
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
iii
Before You Begin
Before You Begin
Document Conventions
The following documentation conventions are used:
Caution A Caution warns the user that failure to heed the information in the
note could result in loss of data. Be sure to carefully read a Caution note and
follow the advice/instructions.
Warning A Warning alerts you of potential physical harm to the user or
hardware. It is critical that you pay strict attention to WARNING notes, read
the information carefully, and follow the advice/instructions.
Tip A Tip provides the user with extra hints/tips to make a task easier to
perform or a concept easier to understand.
Note A Note supplies generic information to the user. The user can ignore the
information and continue the task without suffering any adverse consequences.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
iv
CHAPTER 1
2.4GZ OpenWay Remote Mount Gas Module Installation
2.4GZ OpenWay remote mount gas modules are radio-frequency (RF) devices operating over the 2.4 GHz
frequency. The 2.4GZ OpenWay remote mount gas modules communicate with ZigBee®-compliant electric
meters to transmit gas consumption data. Modules can store 40 days of hourly intervals and are programmed
to bubble-up every 12 or 24 hours. Alternatively, the 2.4GZ OpenWay remote mount gas module can be
awakened with an Itron magnet for programming or for binding to an OpenWay electric meter. When 2.4GZ
Openway gas modules are installed alongside Itron OpenWay electric meters, the OpenWay solution for
combo gas and electric utilities provides unprecedented management flexibility.
This installation guide provides step-by-step instructions to install the 2.4GZ OpenWay remote mount gas
module on a wide variety of meters. 2.4GZ OpenWay remote mount gas module compatible meters are listed
in the Meter Compatibility List.
Transmission Modes
The 2.4GZ OpenWay remote mount gas module can be set to transmit to Standard, Daily or Hourly Mode.
Standard Mode. The 2.4GZ remote mount gas module transmits the current index read and Daily Freeze
Time read; Daily Freeze Time read is programmable for any hour.
Daily Mode. In addition to transmitting Standard Mode information, the 2.4GZ remote mount gas module
transmits 40 days of daily interval data based on Daily Freeze Time reads.
Hourly Mode. In addition to transmitting Standard Mode information, the 2.4GZ remote mount gas
module transmits the last 24 hourly intervals.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
2.4GZ OpenWay Remote Mount Gas Module Installation
Programming Modes
The 2.4GZ OpenWay gas module is programmed or reprogrammed to Normal, Sleep, or Doze Mode as
defined in the configuration file. The table below describes these modes.
Mode
Description/Use Case
Radio
Metering
How to Enter
(counting) this Mode
On
Mag Swipe or
Programmer
How to Exit this Mode
Normal
Normal Operating Mode. Used for On
Field Programming when electric
meters are present or being
installed.
Sleep
For Shipping or Storage of
modules
Off
Off
Programmer
Mag Swipe (to normal) or
Programmer (to specified)
Programmer (can reprogram
to any mode specified)
Uses the least amount of battery
current since the module does not
communicate with the electric
meter.
Snooze
Pre-program modules and deploy
so they try to join the network
automatically when they are
installed in the field. The flow of
gas or Mag Swipe triggers the
module to change to Normal
Mode.
Off
On
Programmer
Mag Swipe (to normal)
Programmer (to specified) or
Count Increment (to normal)
Doze
Pre-program meters in factory and Off
deploy so they do not try to join
the network when installed (for
example, install gas before electric
OR in factory counts will be added
after programming and user does
not want the radio turned on).
On
Programmer
Mag Swipe (to normal) or
Programmer (to specified)
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
2.4GZ OpenWay Remote Mount Gas Module Installation
Specifications
The following tables list the functional and operational specifications for the 2.4GZ OpenWay remote mount
gas module.
Functional Specifications
Power Source
Description
Two "A" cell lithium batteries
Tamper Detection
Tilt tamper
FCC Compliance
Part 15 certified
Industry Canada Compliance
RSS-210 certified
Measurement Canada Approval
Pending
Intrinsic Safety
UL Class I, Division 1, Groups C and D
Product Identification
Numeric and bar coded and serial number
Construction Materials
Gray polycarbonate housing and back plate with encapsulated
electronics
Operational Specifications
Operating Temperatures
Description
-40° to 158° F (-40° to +70° C)
Operating Humidity
5 to 95% relative humidity
Frequency Band
2.405 to 2.475 GHz ISM band
Modulation
Direct Sequence Spread Spectrum
Data Integrity
Verified in every data message
Related Documents
Document Title
Gas Endpoint Meter Compatibility List
Document Part Number
PUB-0117-002
Gas Endpoint Ordering Guide
PUB-0117-001
2.4GZ OpenWay Gas Module Specification Sheet
Publication 100818SP-XX
Endpoint Link Programming Guide
TDC-0744
2.4GZ OpenWay Gas Module Entity Parameters
ENG-2400-500
2.4GZ OpenWay Remote Mount Gas Module Meter Compatibility
List
Note This table lists meters compatible with the 2.4GZ OpenWay remote mount gas module. Due to
continuous research, product improvements, and enhancements Itron reserves the right to change this list
without notice.
Meter
Model
Description
Class
Comments
Endpoint Type
ERT Part
Number
Elster/American/
Canadian
AC250
Aluminum case
coated with twocomponent
polyurethane. Must
have top-reading
odometer-style index
Residential
IPP*
2.4GZ OpenWay Remote
OWG-5001-501
SEP*
2.4GZ OpenWay Remote
OWG-5002-501
AC250 Extended Top
Curb meter
2.5' cable with encoder
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
2.4GZ OpenWay Remote Mount Gas Module Installation
Meter
Model
Description
Class
Comments
Endpoint Type
ERT Part
Number
Elster/American/
Canadian
AC425
Aluminum case
coated with twocomponent
polyurethane. Must
have top-reading
odometer-style index
Residential
IPP*
2.4GZ OpenWay Remote
OWG-5001-501
SEP*
2.4GZ OpenWay Remote
OWG-5002-501
Aluminum case
coated with twocomponent
polyurethane. Must
have top-reading
odometer-style index
Residential
IPP*
2.4GZ OpenWay Remote
OWG-5001-501
SEP*
2.4GZ OpenWay Remote
OWG-5002-501
Iron case
Residential
IPP*
2.4GZ OpenWay Remote
OWG-5001-501
SEP*
2.4GZ OpenWay Remote
OWG-5002-501
Elster/American/
Canadian
Elster/American/
Canadian
AC425 Extended Top
Curb meter
AC630
AC630 Extended Top
Curb Meter
10 Metric (10B)
2.5' cable with encoder
2.5' cable with encoder
2.5' cable with encoder
Sensus/Invensys
National/ Lancaster
Sonix
12,16,25,57,
600,880,2000
All meters
Pulser
Metric
Cubic foot
Commercial
Where direct mount is Residential
not compatible
IPP*
2.4GZ OpenWay Remote 12" OWG-5001-503
lead wires
SEP*
2.4GZ OpenWay Remote 12" OWG-5002-503
lead wires
IPP*
2.4GZ OpenWay Remote
OWG-5001-501
2.4GZ OpenWay Remote
OWG-5002-501
IPP*
2.4GZ OpenWay Remote
OWG-5001-501
SEP*
2.4GZ OpenWay Remote
OWG-5002-501
IPP*
2.4GZ OpenWay Remote
OWG-5001-501
SEP*
2.4GZ OpenWay Remote
OWG-5002-501
IPP*
2.4GZ OpenWay Remote
OWG-5001-501
SEP*
2.4GZ OpenWay Remote
OWG-5002-501
IPP*
2.4GZ OpenWay Remote
OWG-5001-501
SEP*
2.4GZ OpenWay Remote
OWG-5002-501
SEP*
2.5' foot cable with encoder
Itron/Actaris
Schlumberger/ Sprague
1A
Where direct mount is Residential
not compatible
2.5' cable with encoder
Itron/Actaris/
Schlumberger/
Sprague
Metris 250
Straight Face meter
Residential
2.5' cable with encoder
Schlumberger/
Sprague
400
#3 flat-face meter
2.5' cable with encoder
Itron/Actaris/
Schlumberger/
Sprague
675, 1000
Front mount index
Commercial
2.5' cable with encoder
Also requires thicker gasket
for magnet hub to clear index
box.
1-hole gasket: FAB-0014-001
2-hole gasket: FAB-0014-002
4-hole gasket: FAB-0014-003
Elster/American
TC and STD
CTR
American RPM series Commercial
rotary meters
including TC and
non-TC.
IPP*
2.4GZ OpenWay Remote 12" OWG-5001-503
lead wires
SEP*
2.4GZ OpenWay Remote 12" OWG-5002-503
lead wires
Meter must have a factory
installed pulser with connector
output. Purchase endpoint
from Itron and correct cable
interface from appropriate
meter manufacturer.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
2.4GZ OpenWay Remote Mount Gas Module Installation
Meter
Model
Description
Class
Comments
Endpoint Type
ERT Part
Number
Romet
STD CTR
RM series
Commercial
IPP*
2.4GZ OpenWay SE1.0
Remote with 12” lead wires
OWG-5001-503
SEP*
2.4GZ OpenWay SE1.0
Remote with 12” lead wires
OWG-5002-503
600 through 56000
TC
2000-23000
Romet
Meter must have factoryinstalled pulser with connector
output. Purchase endpoint
from Itron and correct cable
interface from appropriate
meter manufacturer.
RM Series 600 through ECM2 Electronically
56000
compensated meter
Commercial
IPP*
SEP*
2.4GZ OpenWay Remote 12" OWG-5001-503
lead wires
2.4GZ OpenWay Remote 12" OWG-5002-503
lead wires
Meter must have connector
pin with factory-installed pulse
output. Purchase endpoint
from Itron and correct cable
interface from Romet. ECM2
must be configured for 750ms
"off-time" between pulses.
The ECM2 must have
firmware version J or later.
Dresser ROOTS®
Dresser ROOTS®
B3/LMMA
Integral Micro
Corrector IMC\W2
MC2
Itron/Actaris
Dattus fM2/fM3
Dresser ROOTS®
rotary meters
equipped with
WeigandWire solid
state pulsers
Commercial
IPP*
2.4GZ OpenWay Remote 12" OWG-5001-503
lead wires
SEP*
2.4GZ OpenWay Remote 12" OWG-5002-503
lead wires
Meter must have factoryinstalled pulser with connector
output. Purchase endpoint
from Itron and correct cable
interface from Dresser.
Dresser pulser must be version
17 or higher to be compatible.
Commercial
Electronic Volume
Corrector for Series A
(LMMA) and Series
B ROOTS® rotary
meters
IPP*
2.4GZ OpenWay SE 1.0
Remote with 12" lead wires
OWG-5001-503
SEP*
2.4GZ OpenWay SE 1.0
Remote with 12" lead wires
OWG-5002-503
Commercial
IPP*
2.4GZ OpenWay Remote 5'
cable
OWG-5001-502
SEP*
2.4GZ OpenWay Remote 5'
cable
OWG-5002-502
Endpoint compatibile with
IMC/W2 firmware version
1.91A or earlier. Pulse width
must be set for 125ms. Pulse
output must be at 100CF(CM)
or higher.
For all meter types, pulse
width must be set to .050
seconds. Meter type 11M or
smaller must have pulse
weight minimum of 10 cubic
feet or 1 cubic meter. Meter
type 16M or greater must
have pulse weight minimum
of 100 cubic feet or 1 cubic
meter.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
2.4GZ OpenWay Remote Mount Gas Module Installation
Meter
Model
Description
Mercury Correctors
EC-AT
Mini-P
Mini-AT
Class
Comments
Endpoint Type
ERT Part
Number
Commercial
Pressure and
temperature electronic
volume correctors
IPP*
2.4GZ OpenWay Remote
5'cable
2.4GZ OpenWay Remote
5'cable
OWG-5001-502
Commercial
IPP*
2.4GZ OpenWay SE 1.0
Remote with 12" lead wires
2.4GZ OpenWay SE 1.0
Remote with 12" lead wires
OWG-5001-504
Mini-Max
Mercury Correctors
TCI
Temperature
Compensating index
SEP*
Correctors must have a Form
A board; Form C is NOT
supported. Item #056 Pulse
Scaling Factor must be set to
2.0. Item #096 Cor Vol
Display must be set at 1, 2, 3,
or 4 blanks. Endpoint does
NOT support 8 digits (0
blanks). Item #1014 set to the
preset "Itron" selection in the
drop-down menu. Item #115
Output Pulse Code must be
set at 1, 2, 3, or 4 (not "0").
SEP*
OWG-5002-502
OWG-5002-504
Correctors must have a Form
A board, Form C is NOT
supported. Item #56 Pulse
Scaling Factor must be 2.0.
Item #96 must be 7, 6, 5, or 4
digits (1, 2, 3, & 4 blanks).
Endpoint does NOT support 8
digits (0 blanks). Item # 1014
set to the preset “Itron”
selection in the drop down
menu. Compatible firmware
versions on TCI are 1.06,
1.07, and 1.10.
*IPP: Itron Private Profile
*SEP: Smart Energy Profile
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
2.4GZ OpenWay Remote Mount Gas Module Installation
Installation Prerequisites
The following tools are required to install, program, and check the 2.4GZ OpenWay remote mount gas
module. Some specific tools may be required dependent on meter or instrument type.
Medium flat-blade screwdriver
Small flat-blade screwdriver
Medium Phillips-drive screwdriver
Hand pliers
Side-cutting pliers
1/4-inch nut driver or similar blunt tool
One-inch width putty knife
Adjustable wrench
3M crimping tool: E-9R, E-9BM, E-9C/CW, E-9E, or E-9Y. Itron recommends the E-9R tool.
All-weather electrical tape
Size T-10 Torx screwdriver
Itron programming device to program and check 2.4GZ OpenWay remote mount gas module installation
and operation:
FC300 with SRead with Endpoint-Link or Endpoint Link Pro version 5.5 or higher or
FC200 (with Bluetooth-enabled) handheld computer loaded with Endpoint-Link or Endpoint-Link Pro
software to program and check endpoint.
ZigBee Belt-clip Radio with Endpoint-Link or EndPoint-Link Pro software - to program and check
2.4GZ OpenWay remote mount gas module installation and operation.
Caution You must program the 2.4GZ OpenWay remote mount gas module with a Bluetoothenabled FC200 or FC300 with SRead handheld computer and ZigBee Belt Clip Radio loaded
with EndPoint-Link Pro software version 5.3.1.26 or version 5.5 for Itron Private Profile (IPP)
gas modules (OWG-5001-XXX).
Endpoint-Link Pro software version 5.5 must be used for Smart Energy Profile (SEP) gas
modules (OWG-5002-XXX).
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
CHAPTER 2
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
This chapter provides the instructions to mount the 2.4GZ OpenWay remote mount gas module on a pipe or
other flat vertical surface (wall).
Installation Options
Mount the 2.4GZ OpenWay remote mount gas module using the Pipe Mount or Wall Mount (Flat Surface)
procedure.
Pipe Mount. Pipe mounting is used in conjunction with the Remote Mount Kit (Itron part number CFG0005-003). The pipe mount option places the endpoint on a pipe near the meter or instrument (not on a
wall surface). This option requires a meter manufacturer's cable to connect the endpoint to the meter or
instrument.
Flat Vertical (Wall) Mount. Installation using the wall mount option places the endpoint on a wall or
other vertical surface. A cable connects the endpoint to the meter or instrument.
Mounting Screw Specifications
Application
Itron Part
Number
Description
To mount adapter plates on
pipe brackets
575-9930-016
8-16 x 1/2-inch length, Type 8 slotted pan-head
tapping screw - corrosion-resistant steel
To mount endpoints on adapter 575-9930-032
plates
8-16 x 1-inch Type 8, slotted pan-head tapping
screw, corrosion-resistant steel
To mount endpoints on sheet
metal surfaces (to mount
endpoints to wood surfaces, a
comparable wood screw is
required)
10-16 x 1 1/2-inch Type AB thread for sheet
metal, Phillips pan-head tapping screw, corrosionresistant steel
SCR-0009-001
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
Mounting Installation Considerations
Select a proper mounting location. Itron recommends mounting the 2.4GZ OpenWay remote mount gas
module in close proximity to the meter or instrument. Some applications may require an extended cablelength. The 2.4GZ OpenWay remote mount gas module supports cable lengths up to 300 feet.
Mount the 2.4GZ OpenWay remote mount gas module in a vertical position with the endpoint label
directional arrow pointed upward or downward.
Caution Vertical mounting position is important to maximize RF performance. You can
mount a 2.4GZ OpenWay remote gas module with the module's label arrow pointing up or
down, dependent upon the application as noted in relevant sections of this installation
manual. The module's arrow must never point to either side. The module's tilt tamper
functionality is designed to operate with the module installed vertically. The 2.4GZ
module's tilt tamper will operate with the label arrow pointed up or down. The module's tilt
tamper will not operate with the module installed horizontally (the label arrow pointed to
either side).
Warning Do not mount the 2.4GZ OpenWay remote mount gas module in an orientation
other than vertical (endpoint label arrow pointed upward or downward). Violating the
mounting orientation requirements will void the product warranty.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
Mounting the 2.4GZ OpenWay Remote Mount Gas Module on a Pipe
The following items are required to mount the 2.4GZ OpenWay remote mount gas module on a pipe or
vertical flat surface (wall):
Itron Part Number
Description
OWG-5001/5002-501
2.4GZ OpenWay remote mount gas
module
OWG-5001/5002-502
OWG-5001/5002-503
OWG-5001/5002-504
OWG-5001-501 shown
CFG-0005-003
Remote Mount Installation Kit
Kit includes:
(2) two band clamps
(2) two tamper seals
pipe bracket
cable ties
adapter plate
Screws - (2) 1/2" - to
attach the adapter
plate to pipe bracket
(2) 1" - to attach the endpoint to the
adapter plate
(3) 1 1/2" - to attach the endpoint to a
vertical surface (wall)
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
10
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
To mount the pipe bracket on a vertical pipe
Caution Vertical mounting position is important to maximize RF performance. You can mount
a 2.4GZ OpenWay remote gas module with the module's label arrow pointing up or down,
dependent upon the application as noted in relevant sections of this installation manual. The
module's arrow must never point to either side. The module's tilt tamper functionality is
designed to operate with the module installed vertically. The 2.4GZ module's tilt tamper will
operate with the label arrow pointed up or down. The module's tilt tamper will not operate with
the module installed horizontally (the label arrow pointed to either side).
1. Remove the pipe bracket and band clamp from the Remote Mount Installation Kit (Itron part number
CFG-0005-003).
2.
Loosen the band clamp screw until the end of the band releases.
3. Push the end of the clamp's band (1) through the holes (2) in the pipe bracket. The pipe bracket must be
oriented as shown below.
4. Place the band clamp around the pipe. The band will loosely wrap around the pipe. Push the end of the
band through the band clamp screw assembly. Turn the band clamp's screw assembly to fit into the pipe
bracket opening. Tighten the clamp screw until the band clamp is secure on the pipe.
Caution The pipe bracket must fit firmly against the pipe to prevent slippage.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
11
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
To mount the adapter plate on the pipe bracket
Caution Vertical mounting position is important to maximize RF performance. You can mount
a 2.4GZ OpenWay remote gas module with the module's label arrow pointing up or down,
dependent upon the application as noted in relevant sections of this installation manual. The
module's arrow must never point to either side. The module's tilt tamper functionality is
designed to operate with the module installed vertically. The 2.4GZ module's tilt tamper will
operate with the label arrow pointed up or down. The module's tilt tamper will not operate with
the module installed horizontally (the label arrow pointed to either side).
1. Place the adapter plate on the pipe bracket with the mounting lug at the top or bottom. The adapter plate
screw bosses fit into the pipe bracket recess.
2. Ensure the adapter plate is positioned as shown below with the mounting lug (1) at the top or bottom. To
install the adapter plate on a vertical pipe, use the two shortest (1/2-inch) adapter plate mounting screws
from the Remote Mount Installation Kit. Place the mounting screws (2) in the holes shown below.
Upright module mounting
Inverted module mounting (curb meter)
3. Tighten both screws securely in an alternating fashion. Itron recommends 9 to 12-inch-pounds torque.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
12
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
To mount the 2.4GZ OpenWay remote mount gas module on the adapter plate
1. Take the 2.4GZ OpenWay remote mount gas module and the two 1-inch mounting screws from the
Remote Mount Installation kit. Place the back of the remote endpoint against the face of the adapter plate.
The adapter plate mounting lug (1) must be positioned just above the endpoint mounting lug recess (2).
2. Push up on the 2.4GZ OpenWay remote mount gas module until the adapter plate mounting lug (1) is as
far as possible inside the endpoint mounting lug recess (2).
3. Install the two 1" endpoint-mounting screws from the installation kit.
4. Tighten the endpoint mounting screws evenly in an alternating fashion. Itron recommends 9 to 12 inchpounds torque.
Adapter Plate Mounting Positions
The following pictures show adapter plates mounted on horizontal or 45-degree angle pipes.
Caution Regardless of the pipe's direction, the adapter plate mounting lug must always be at the top or
bottom. (Bottom lug installation for inverted curb meter module mounting).
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
13
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
If the pipe is a 45-degree angle up to the right, install the adapter plate as shown below.
Typical module mounting Inverted module mounting
(curb meter)
Mounted adapter plate
back view
If the pipe is a 45-degree angle up to the left, install the adapter plate as shown below.
Typical module mounting Inverted module mounting
(curb meter)
Mounted adapter plate
back view
If the pipe is horizontal, install the adapter plate as shown below.
Typical module mounting Inverted module mounting
(curb meter)
Mounted adapter plate
back view
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
14
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
To install tamper seals and cable ties
1. Ensure the label arrow points up or down (1). Place the new tamper seals from the Remote Mount
Installation Kit over the 2.4GZ OpenWay remote mount gas module mounting screws (2, 3). Firmly push
both tamper seals all the way into place with a 1/4-inch nut driver or similar blunt tool.
Note A tamper seal is fully seated when the top of the tamper seal is approximately 1/16-inch below the
top of the screw recess.
2. Gather any excess endpoint cable. Loop a cable tie around the pipe and excess endpoint cable.
3. Insert the chiseled end of the cable tie into the locking end and pull the cable tie tight. Cut off and properly
dispose the excess cable tie.
2.4GZ OpenWay remote mount gas module pipe mount installation is complete.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
15
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
Mounting the Endpoint on a Wall or Other Flat Vertical Surface
Caution Vertical mounting position is important to maximize RF performance. You can mount a
2.4GZ OpenWay remote gas module with the module's label arrow pointing up or down, dependent
upon the application as noted in the relevant section of this installation manual. The module's arrow
must never point to either side. The module's tilt tamper functionality is designed to operate with the
module installed vertically. The 2.4GZ module's tilt tamper will operate with the label arrow pointed
up or down. The module's tilt tamper will not operate with the module installed horizontally (the label
arrow pointed to either side).
To mount the 2.4GZ OpenWay remote mount gas module on a wall or other flat vertical
surface
Note For easier installation, you may drill three pilot holes in the mounting surface (use the proper size
drill bit to accommodate the endpoint mounting screws, see the Drilling Template below). When drilling
pilot holes to mount the 2.4GZ OpenWay remote mount gas module, the holes for the two bottom screws
must be on a horizontal line. If the endpoint will be mounted on a sheet metal surface, use the mounting
screws included with the 2.4GZ OpenWay remote mount gas module mounting kit. Use a comparable
wood screw to mount the endpoint on a vertical wood surface.
Carefully select a mounting location free from electrical wires. The mounting location must have the
proper clearance to accommodate the 1-1/2-inch endpoint mounting screws so nothing is damaged by the
drill or mounting screws.
2.4GZ OpenWay remote mount gas module drilling template
A 3 inches
B 1-11/16 inches
C 3-3/8 inches
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
16
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
1. Using the three 1-1/2-inch mounting screws from the Remote Mount Installation Kit, turn the mounting
screw for the mounting lug (top of endpoint) part way into the mounting surface.
2. Place the 2.4GZ OpenWay remote mount gas module mounting lug recess (on the top of the endpoint
backplate) just under the screw head. Slide the endpoint upward until the screw head fits completely inside
the mounting lug recess. Several adjustments may be necessary to properly position the screw for endpoint
mounting.
3. Install the bottom two mounting screws. Fasten screws in an alternating fashion until fully tightened to
secure the endpoint firmly in position.
To install tamper seals and cable ties
1. Place a new tamper seal (from the Remote Mount Installation Kit) over each endpoint mounting screw.
2. Firmly push both tamper seals into place with a 1/4-inch nut driver or similar blunt tool.
Note A tamper seal is fully seated when the top of the tamper seal is approximately 1/16 inch below the
top of the screw recess.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
17
Mounting the 2.4GZ OpenWay Remote Mount Gas Module
3. To reduce the risk of cable damage, secure the excess endpoint cable with the cable ties from the Remote
Mount Installation Kit. Pull the cable tight. Remove and properly dispose the excess cable tie.
2.4GZ OpenWay remote mount gas module installation on a vertical flat surface or wall is complete.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
18
CHAPTER 3
Rotary Meter Installation
This chapter provides the instructions to install the 2.4GZ OpenWay remote mount gas module on rotary
gas meters. Reference the Gas Endpoint Meter Compatibility List (see Related Documents on page 3) for
rotary meters compatible with the 2.4GZ OpenWay remote mount gas module.
American rotary meter
Dresser ROOTS®Series LMMA rotary meter
Dresser ROOTS® series B3 meter
Dresser ROOTS®IMC\W2 meter
Romet Imperial series RM meter
Romet Imperial ECM2 meter
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
19
Rotary Meter Installation
Required Installation Materials Available from Itron
The materials in the following table are required to install a 2.4GZ OpenWay remote mount gas module.
Itron Part Number
OWG-5001-503
OWG-5002-503
Note: this remote mount endpoint comes
standard with 12" lead wires and may be
shipped directly to the meter manufacturer for a
factory-installed cable (interface).
Important The interface cable must be purchased directly from the meter manufacturer.
CFG-0005-003
Remote Endpoint Mounting Kit
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to
the Rotary Meter Cable
You may ship the Itron 2.4GZ OpenWay remote mount gas module directly to the meter manufacturer for a
factory-installed cable. If you connect the endpoint to the meter using an existing cable purchased from the
meter manufacturer, complete the following cable installation procedure.
Caution The purchased cable must have a mating connector compatible to the meter receptacle.
Dresser ROOTS® cables may be wired in different configurations for specific applications. If
necessary, contact Dresser ROOTS® Meters for wiring diagrams for your specific application.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
20
Rotary Meter Installation
To connect the 2.4GZ OpenWay remote mount gas module to the rotary meter cable
1. Remove the backplate (4 screws) from the 2.4GZ OpenWay Remote and expose the module's lead
wires. The backplate and screws will be re-installed on the gas module later in this procedure so store
them (temporarily) in a safe, secure place.
2. Insert the lead wires from the 2.4GZ OpenWay remote mount gas module into new 3M gel connectors
(Itron part number CON-0023-001) together with the same colored lead wire from the meter cable (see
the wiring table below) and crimp using a 3M hand-held crimping tool.
Note Do not strip lead wire prior to inserting the wire in the gel connector.
Rotary Meter to Remote Module Wire Table
Rotary Meter Wire Remote module wire
Red
Red
White
White
Blue
Blue
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
21
Rotary Meter Installation
3. After completing the wiring connections, install a cable tie to the meter cable just below the exposed
colored lead wires on the cable insulation. Remove the excess cable tie using a hand-held sidecutter
pliers. The cable tie performs as a cable strain relief to mitigate the risk of destructive tension on the
lead wires.
4.
Tuck the three gel connectors and cable tie inside the module housing. Position the cable tie as shown
in the placement schematic below.
5. Install the 2.4GZ OpenWay remote mount gas module backplate using the four screws previously
removed from the module and a Torx T-15 screwdriver. Install the new 2.4GZ OpenWay remote mount
gas module on the wall or a pipe using the Remote Endpoint Mount Kit (Itron part number CFG-0005003). See Mounting the 2.4GZ OpenWay Remote Mount Gas Module on page 8 for mounting
instructions.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
22
Rotary Meter Installation
To connect the 2.4GZ OpenWay remote mount gas module cable assembly to the rotary
meter
Caution Verify the cable connector mates with the meter connector. Meter manufacturers use
different connector styles (types).
1. Align the large lug on the 2.4GZ OpenWay remote mount gas module connector with the large notch on
the meter connector.
2. Align the lock ring notches on the module cable connector with the pins on the meter connector.
3. Hold the lock ring on the module connector back and push the plug into the meter connector until it is
securely seated.
4. Turn the lock ring clockwise as far as it will go. You will feel it snap into place when it locks.
Warning To remove the module connector plug from the meter connector jack, push in on the lock
ring, turn the lock ring counterclockwise as far as possible, and pull out the plug body. Do not pull on
the module's connector cable.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
23
Rotary Meter Installation
Programming 2.4GZ OpenWay Remote Mount Gas Modules for
Dresser ROOTS® Rotary Meters
To program 2.4GZ OpenWay remote mount gas modules for use with Dresser ROOTS® rotary meters, use
the meter drive rates from the drive rate table in this section.
B3, LMMA & S3A CTR/TC Meter Pulse Rates for Remote Module
Programming
Caution Do not use these meter drive rates to program residential direct-drive or commercial directdrive modules. Use the information in the following tables to program 2.4GZ OpenWay remote mount
gas modules connected to Dresser ROOTS® rotary meters.
B3 CTR Meter Size
B3 CTR Meter Pulse Rate
LMMA CTR Meter Size
LMMA CTR Meter Pulse Rate
8C
10
1.5M
10
11C
10
3M
10
15C
10
5M
10
2M
10
7M
10
3M
10
11M
10
5M
10
16M
100
7M
10
23M
100
11M
10
38M
100
16M
100
56M
100
23M
100
102M
100
38M
100
56M
100
LMMA CTR Meter Size
LMMA CTR Meter Pulse Rate
LMMA TC Meter Size
LMMA TC Meter Pulse Rate
1.5M
10
1.5M
10
3M
10
3M
10
5M
10
5M
10
7M
10
7M
10
11M
10
11M
10
16M
100
16M
100
23M
100
38M
100
56M
100
102M
100
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
24
Rotary Meter Installation
Meters built 1/99 and beyond
B3 TC Meter Size
B3 TC Meter Pulse Rate
Meters built prior to 1/99
B3 TC Meter Size
B3 TC Meter Pulse Rate
8C
10
8C
50
11C
10
11C
50
15C
10
15C
50
2M
10
2M
50
3M
10
3M
50
5M
10
5M
50
7M
10
7M
50
11M
10
11M
50
16M
100
16M
500
S3A CTR Meter Size
S3A CTR Meter Pulse Rate
S3A TC Meter Size
S3A TC Meter Pulse Rate
1.5M
10
1.5M
10
3M
10
3M
10
5M
10
5M
10
7M
10
7M
10
11M
10
11M
10
16M
100
16M
100
Installing the 2.4GZ OpenWay remote mount gas module to
the Elster American Meter RPM Series Rotary Meter
Some meter manufacturers provide endpoint mounting kits and installation procedures for their meters. If
2.4GZ OpenWay remote mount gas module to Elster American RPM meter installation instructions are not
available, follow the installation procedure in this section.
Elster American Meter RPM Series Rotary Meter
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
25
Rotary Meter Installation
To install the 2.4GZ OpenWay remote mount gas module on an Elster American RPM
series meter
1. Remove the meter's top plate by removing the two (2) 5mm screws and carefully prying up on the plate.
The plate is secured with an o-ring seal. Remove the o-ring from the plate.
Caution If the o-ring is damaged during removal, obtain a replacement from Elster American Meter
Co.
2. Look into the meter tower and find the meter switch lead and connector (4-pin).
3. If the lead and connector are not visible or cannot be found, remove the four (4) 5mm mounting screws
and the register cover. The meter switch lead and connector will be visible inside the cover.
Note Save any meter tags. You will re-install them later in the installation process.
4. Feed the lead and connector into the register cover tower.
5. If you removed the register cover, replace the cover using the four (4) 5mm mounting screws.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
26
Rotary Meter Installation
6. Attach the 4-pin male connector on the Elster American Meter adapter plate to the 4-pin female
connector inside the meter's tower. The connectors will slide together and latch.
7. Carefully push the connectors and wires into the meter tower housing.
8. Lubricate the o-ring with o-ring lubricant and install the o-ring on the adapter plate. Insert the adapter
plate into the tower and tighten the (2) 5 mm screws.
To connect the manufacturer cable to the endpoint
Note Connection to an Elster American Meter requires a cable interface compatible to an Elster
American Meter RPM rotary meter.
1. Trim the 2.4GZ OpenWay remote mount gas module wires to 3.5-inches.
2. Carefully strip the insulation covering from the meter cable (purchased from the meter manufacturer)
approximately 1-1/2-inces from the end.
Caution Do not cut through the individual wire insulation.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
27
Rotary Meter Installation
3. Separate the black, white, and blue wires for connection to the 2.4GZ OpenWay remote mount gas
module. Cut off the unused wires even with the outer covering (insulation).
Caution Do not strip the individual wires.
4. Connect the meter cable to the 2.4GZ OpenWay remote mount gas module using 3M gel-cap
connectors. Follow the wire connection table and wiring diagrams below. See Installation Prerequisites
on page 7 for appropriate 3M crimping tools.
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for
crimping gel-connects. The crimping tool provides an even pressured crimp to make a secure
connection. Apply pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time
for the low viscosity silicone-based gel to flow. If the silicone gel flows out of the crimped connector,
avoid touching the gel. Gel flowing from the connector provides environmental protection for the
connection.
American RPM Meter to 2.4GZ Remote Mount Module Wire Connections
American RPM Meter wire
2.4GZ remote mount module wire
Red
Red
White
White
Black
Blue
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
28
Rotary Meter Installation
5. Insert the meter cable through the slot on the module backplate. Install a cable tie to the meter cable
wire below the meter cable insulation to provide strain relief. Position the cable tie as shown in the
position schematic below.
6. Tuck the connectors and cable tie into the endpoint housing. Place backplate on the assembly and
tighten the four backplate screws using a size T-10 Torx screwdriver.
Important Verify the cable tie and gel connectors are inside the endpoint housing and the cable
extends out of the slot in the backplate. Torque the backplate mounting screws to 9 - 12 inch-pounds.
To install the 2.4GZ OpenWay remote mount gas module cable
1. Insert the plug on the cable connected to the module into the receptacle on the meter adapter plate.
2. Tighten the threaded collar on the plug onto the American Meter interface receptacle. Verify the
connection is hand-tight.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
29
Rotary Meter Installation
Mounting the 2.4GZ OpenWay Remote Mount Module
Select an appropriate mounting location on adjacent piping close to the meter. Using the pipe bracket,
mounting plate and band clamps from the Remote Mount Kit (Itron part number CFG-0005-003), secure the
2.4GZ OpenWay remote mount gas module. Use the cable ties from the kit to secure any excess wire to the
piping (see Mounting the 2.4GZ Remote Mount Module on a Pipe on page 9).
Installing the 2.4GZ OpenWay Remote Mount Gas module to
the Romet Electronically Compensated Meter (ECM2®)
The Romet ECM2® meter has three Form "A" outputs that can be configured at the factory to provide any
combination of the following three outputs:
Uncorrected volume (UNC VOL)
Corrected volume (COR VOL)
Alarm
The pulse weight for the volumetric outputs is configured in SetUp Mode at Menu items>SET UNC OUT
and SET COR OUT. Since Setup Mode is fully configurable, the ECM2® module is universally adaptable
to all Romet TC meter bodies. Reference the Romet technical manual for specific details on the ECM2®.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
30
Rotary Meter Installation
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to
the Romet ECM2® Meter
Connect the correct interface wirings and set the output pulse spacing to complete 2.4GZ OpenWay remote
mount gas module installation with the Romet ECM2® meter. See the ECM2® Interface Wiring Table below
to complete wire connections.
Function
(+)UC
(-)UC
(+)CC
(-)CC
(+)ALM
Endpoint Wire
White and
Blue
Red
White and
Blue
Red
White and
Blue
Red
34-125-20
34-125-40
34-125-41
34-125-42
Pin location
for Cannon
Connector
Part Number
34-125-43
(-)ALM (+)Aux.CC (-)Aux.CC
34-125-44
34-125-45
34-125-50
34-125-51
White and
Blue
Red
Caution Set the ECM2® output pulse spacing to 750ms for operation with the 2.4GZ OpenWay
remote mount gas module. Output spacing represents an off-time between pulses.
Romet ECM2 Mounting Requirement
This mounting procedure requires the Romet ECM2/ERT Mounting Kit (Romet part number 34-444-1KIT).
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
31
Rotary Meter Installation
To mount the 2.4GZ OpenWay remote mount gas module on the Romet ECM2 meter
1. Remove the module screw from the back of the ECM2 meter and discard.
2. Insert the mounting screw fitted with the three lock washers. Two lock washers are used as spacers as
shown.
3. Attach the mounting plate to the meter. Insert the mounting screw where the module screw was
removed. Torque the mounting screw to 5 - 7 ft.lbs. to secure the plate to the Romet meter.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
32
Rotary Meter Installation
4. Mount the 2.4GZ OpenWay remote mount gas module using the pre-drilled holes on the mounting plate
and the module mounting screws. Place new tamper seals over the two screws. Press tamper seals into
place using an 11/32" nut driver or similar blunt tool. Connect the module to the meter using the
previously installed cable interface.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
33
Rotary Meter Installation
Programming the 2.4GZ OpenWay Remote Mount Gas Module
Assembly
Caution The 2.4GZ Remote Mount Gas Module must be programmed before use.
Program the 2.4GZ OpenWay remote mount gas module with a Bluetooth-enabled FC200 or FC300
with SRead handheld computer and ZigBee Belt Clip Radio loaded with Endpoint-Link or EndpointLink Pro software version 5.3.1.26 or version 5.5 for Itron Private Profile (IPP) gas modules (OWG5001-XXX). Endpoint-Link Pro software version 5.5 must be used for Smart Energy Profile (SEP) gas
modules (OWG-5002-XXX). See the Endpoint-Link Endpoint Programming Guide (TDC-0744) for
more complete programming information. An Itron magnet is also required for programming.
FC200SR
FC300 with SRead Zigbee Belt Clip Radio Itron Magnet
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
34
Rotary Meter Installation
To program the 2.4GZ OpenWay remote mount gas module
1. Program the meter drive rate into the 2.4GZ OpenWay remote mount gas module using the handheld
computer and Belt Clip Radio. Programming parameters are based on the configuration file loaded into
the handheld computer.
2. Place the magnet over the barcode on the module cover label with the magnet face (inked Itron logo and
part number) arrow pointed up toward the top of the module.
3. Hold the magnet in place for 5 seconds and remove it.
4. The LED will blink red three times. This signifies the 2.4GZ OpenWay remote mount gas module is
searching for a programming device. Within a few seconds of locating the handheld computer, the red
LED will blink five more times. The handheld computer will confirm programming success or failure.
5. Read the 2.4GZ OpenWay remote mount gas module using the handheld computer and Belt Clip Radio.
If the read result is higher than the number programmed in Step 1, the 2.4GZ OpenWay remote
mount gas module is counting correctly.
If the read result is not higher than the number programmed in Step 1, replace the 2.4GZ OpenWay
remote mount gas module.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
35
CHAPTER 4
Electronic Instrument Installation
This section provides the instructions to install the 2.4GZ OpenWay remote mount gas module on the
Mercury Instruments Mini-P, Mini-AT, Mini-Max, and EC-AT and Dresser ROOTS® Micro Correctors.
Mini-AT
TCI
Mini-Max
IMC/W2
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
EC-AT
MC2
36
Electronic Instrument Installation
Installation Prerequisites
2.4GZ OpenWay remote mount gas module installation to a Mercury Instrument requires:
2.4GZ OpenWay remote mount gas module compatible to a Mercury Instrument (see the 2.4GZ OpenWay
Remote Mount Gas Module Meter Compatibility List on page 3).
Mercury Instrument compatible with the remote endpoint.
Proper tools and devices for installation and programming (see Installation Prerequisites on page 7).
Installation Overview
Installing the 2.4GZ OpenWay remote mount gas module to a Mercury Instrument involves five tasks:
1. Programming the Mercury Instrument on page 37 (reference the Mercury Instrument Programming Guide
for more information).
2. Installing Mercury retrofit parts (if necessary).
3. Attaching the 2.4GZ OpenWay remote mount gas module to a pipe or vertical flat surface (wall) (see
Mounting the 2.4GZ OpenWay Remote Mount Gas Module on page 8).
4. Wiring the 2.4GZ OpenWay remote mount gas module to the Mercury Instrument (see Wiring the 2.4GZ
OpenWay Remote Mount Gas Module to the Mercury Instrument on page 39).
5. Programming the 2.4GZ OpenWay remote mount gas module (see Programming the 2.4GZ OpenWay
Remote Mount Gas Module).
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
37
Electronic Instrument Installation
Programming the Mercury Instrument
Code Settings
Volume
Corrector
Type
Item Code Settings and Corresponding Terminal Board Channel
Pulse Output Options Channel A
Channel B
Terminal Board Connections*
Channel C
Number of
Pulse Output Spacing
Blanked digits on
CorVol Display
Ka, Ya = Channel A
#056
#93 #057 #094 #058 #095 #96
#115
#1014
#1015
Pulse Board Ver-1(3)
Form-C
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Module does not support a Form-C
pulse output board.
Pulse Board Ver-2(3)
Form-A
2.0000
2.0000 0
2.0000 0
1, 2, 3, or 4
1, 2, 3, or 4
n/a
n/a
Ka, Kb, Kc (Red Wire)
Ya, Yb, Yc (Blue & White Wire)
Connection must be on same terminal
board channel (for example, Ka/Ya;
Kb/Yb; Kc/Yc).
Pulse Board Ver-3(2)
Form-C1 Form-A
n/a
n/a
n/a
n/a
2.0000 0
1, 2, 3, or 4
1, 2, 3, or 4
n/a
n/a
Kc (Red Wire) Y (Blue & White
Wire). For this option, module must be
connected to Channel C.
Mini with
Form A
Mainboard
Main Board Type-2
2.0000
n/a
n/a
n/a
n/a
1, 2, 3, or 4
1, 2, 3, or 4
n/a
n/a
K (Red Wire) Y (Blue & White Wire).
For optional SPA Bd., jumper must be
installed on J1-B as indicated in the
Mercury Quick Reference Guide (page
148) for Form A.
Mini-AT
JB29, JB30 & JB31
Jumpered for Form-A
2.0000
2.0000 0
n/a
n/a
1, 2, 3, or 4
1, 2, 3, or 4
n/a
n/a
K (Red Wire) Y (Blue & White Wire).
For optional SPA Bd., jumper must be
installed on J1-B as indicated in the
Mercury Quick Reference Guide (page
148) for Form-A.
JB29, JB30 & JB31
Jumpered for Form-C
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Module does not support a Form-C
pulse output board.
All Main Boards
n/a
n/a
1, 2, 3, or 4
1, 2, or 4
n/a
n/a
K (Red Wire) Ya or Yb (Blue & White
Wire)
Form C Main Board
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Module does not support a Form-C
pulse output board.
Form A Main Board
2.0000
2.0000 0
n/a
n/a
1, 2, 3, or 4 blanks n/a
(7, 6, 5, or 4 active)
ECAT
Mini-Max
n/a
n/a
n/a
Itron selection Itron selection
in dropdown in dropdown
menu.
menu
Connections to channels of output
pulses are made through loose
unterminated cable wires and gel
connect connectors.
Notes:
Code 0 for items 093, 094 & 095 = Corrected Volume Pulse Data
Code 1 for item 115 = 1.000 Sec.
Code 2 for item 115 = 2.000 Sec.
Code 1 for item 096 = blank 1 digit and display 7 digits
Code 2 for item 096 = blank 2 digits and display 6 digits
Code 3 for item 096 = blank 3 digits and display 5 digits
Code 4 for item 096 = blank 4 digits and display 4 digits
*For more information, see pages 11-20 of the "Basic Pulse Information for Mercury Instruments, Inc., Electronic Volume Correctors" manual, or contact Mercury Instruments at 513-2721111.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
38
Electronic Instrument Installation
Mercury corrector programming parameters:
Caution A Mercury Instrument Volume Correctors must have a Form A board. A Form C board
is not compatible with the 2.4GZ OpenWay remote mount gas module.
For TCI, when using both outputs, items 1014 and 1015 must be set to Itron.
Item #056: Pulse A Scaling. Set at 2.0000 for a form A switch.
Item #057: Pulse A Scaling. Set at 2.0000 for a form A switch.
Item #058: Pulse A Scaling. Set at 2.0000 for a form A switch.
Item #090: Corrected Volume Units: Code (0-20) selects the unit of measure for Corrected Volume
(Item000) and other "CorrVol" related items.
Item #092: Uncorrected Volume Units: Code (0-20) selects the unit of measure for Uncorrected Volume
(Item002) and other "UncVol" related items.
Item # 093, 094, 095: Type of gas volume information to be sent. For "CorrVol" selected, must be set at 0.
Item # 096: Corrected Volume Display: Must be set at 1, 2, 3 or 4 blanks. Endpoint does not support a
setting of 0 blanks.
Item # 097: Uncorrected Volume Display: Must be set at 1, 2, 3, or 4 blanks. Endpoint does not support a
setting of blanks.
Item # 098: Check drive rate of the corrector. Should be the same as the plate above the uncorrected dials
and the same as the plate on the index drive of the meter.
Item # 115: Output Pulse Code: Must be set at 1 or 2.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
39
Electronic Instrument Installation
Wiring the 2.4GZ OpenWay Remote Mount Gas Module to the
Mercury Instrument
Use the Terminal strip connector (Phoenix connector) in the Mercury Instrument to connect the 2.4GZ
OpenWay remote mount gas module to the instrument.
Note In Mercury Instrument EC-AT correctors, the connector may be soldered to the pulse
board.
The 2.4GZ OpenWay remote mount gas module has three lead wires (red, white, and blue). The red wire is
attached according to Mercury Instrument Code Settings (see Code Settings on page 38).
The blue and white wires are twisted together and attached according to Mercury Instrument's Code Settings
(see Code Settings on page 38).
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
40
Electronic Instrument Installation
To wire the 2.4GZ OpenWay remote mount gas module to the Mercury Instrument
1. Insert the module cable into the instrument's compression connector.
2. Strip one inch of the outer insulation from the 2.4GZ OpenWay remote mount gas module. Strip 1/4-inch
individual wire insulation from the red, white, and blue lead wires.
A White wire
B Blue wire
C Red wire
Caution Keep wires away from the rotating magnetic spindle in the Mercury Instrument.
3.
See Mounting the 2.4GZ OpenWay Remote Mount Gas Module on page 8 for module mounting
instructions.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
41
Electronic Instrument Installation
Wiring Dual Modules to a Mercury Instrument
This section includes the information to wire dual endpoints to a single Mercury Instrument. Installation
requires the correct programming parameters (see Code Settings on page 38).
With Itron 2.4GZ OpenWay remote mount gas modules, utilities can receive corrected and uncorrected
consumption values by installing two modules. The module for corrected reads is attached to the instrument's
pulse output. The module for uncorrected reads is attached to the input switch board. The corrected pulse
output is programmable; the uncorrected pulse output is dependent on the connected meter's drive rate.
Important Some Mercury Instruments have two pulse outputs so the
uncorrected pulse output could be connected to the additional output, but the
connection should be to the input switch board in case the instrument battery
fails. Counts will be collected if the uncorrected pulse is connected to the switch
board since the board is not dependent on battery power.
Dual remote modules mounted on a Mercury Instrument
To install dual 2.4GZ OpenWay remote mount gas modules to a Mercury Instrument Mini-Max
Case Corrector using Mercury Kit 22-1077
Required Tools
Drill with 3/16-inch bit
Screw drivers: slotted and Phillips head (medium size)
1-inch open-end wrench or medium-size adjustable wrench
7/16-inch open- or closed-end wrench
Clean shop rag
Alcohol wipe
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
42
Electronic Instrument Installation
1. Place the Mercury Instrument in shutdown condition and disconnect all power from the Mini-Max main
board.
2. Remove the battery pack from the corrector and set aside.
3. Remove the four screws from the main board and the board from the enclosure. Set the board aside.
4. Remove the two hex screws from the input switchboard and the switchboard from the enclosure and set
aside.
Warning The battery pack, main board and switchboard may be damaged if left in the Mercury
Instrument while completing this installation.
5. Drill two 3/16-inch holes in the back of the Mini-Max enclosure as specified by the information included
in the kit. Remove any metal shavings from the enclosure.
6. Clean the 2.4GZ OpenWay remote mount gas modules with the alcohol wipe where you will place the
Corrected and Uncorrected labels (included in the kit).
Note Clean the 2.4GZ OpenWay remote mount gas modules with the alcohol wipe to ensure good label
adhesion.
7. Mount the module for corrected pulse outputs on the left bracket mounting space. Insert three #8-32 x 1/2inch screws in a triangular pattern. Install the top screw so the head of the screw is approximately 1/8-inch
from the module mounting bracket surface. Slide the module onto the screw so the mounting lug fits
securely onto the screw. If necessary, remove the module and make any necessary adjustment to the screw
depth to ensure a secure fit. Install the two bottom screws in an alternating fashion.
8. Mount the module for uncorrected pulse outputs on the right bracket mounting space. Insert three #8-32 x
1/2-inch screws in a triangular pattern. Install the top screw so the head of the screw is approximately 1/8inch from the Module Mounting Bracket surface. Slide the module onto the screw so the mounting lug fits
securely onto the screw. If necessary, remove the module and make any necessary adjustment to the screw
depth to ensure a secure fit. Install the two bottom screws in an alternating fashion.
9. Route the module cables under the bracket edge and toward the rear of the Mercury Instrument.
10. Mount the Module Mounting Bracket (Mercury Instrument part number 22-1077, included in the kit) onto
the Mini-Max enclosure. Place a #8 metal flat washer followed by a rubber sealing washer onto both #832 x 3/8-inch screws. Align the lower threaded holes in the mounting bracket with the drilled enclosure
holes and insert a screw/washer through the enclosure housing. Screws heads must be inside the enclosure.
Tighten both screws using a screwdriver.
Note Aligning the second bracket threaded hole and drilled hole may require some manipulation of the
mounting bracket.
11. Insert the module cables (both units) through the large cable strain relief on the left rear of the corrector's
enclosure. Leave a one-half to one inch drip loop under the cable strain relief.
12. Secure three cable ties on the module cables in three places on the cables as specified by information
included in the kit.
13. Re-install the input switchboard, main board, and battery pack removed in Step 2.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
43
Electronic Instrument Installation
14. Connect the corrected module wires to TB1 on the Mini-Max board following the table below. Use
Mercury upgrade kit 40-2678-1 to provide the second pulse output channel for the uncorrected module.
Corrected Module Connections
Module
Red wire
Mini-Max TB1
K terminal
Blue wire*
Ya terminal
White wire*
Ya terminal
*Twist the blue and white module wires together before connecting to the Mini-Max board.
Tighten terminal connections securely.
15. Connect the uncorrected module wires to the Input Switch Board UNC.VOL following the table below.
Uncorrected Module Connections
Endpoint
Red wire
Mini-Max Input
Switch Board UNC. Vol.
COM terminal
Blue wire
NO terminal
White wire
NO terminal
*Twist the blue and white module wires together before connecting to the Mini-Max board.
16. Tighten terminal connections securely.
17. Tighten the large strain relief securely.
Warning Do not crush the module through cables when tightening the strain relief.
18. Re-install or reconnect the power or battery sources.
19. Close the instrument case and tighten the case screw securely. Replace any locks that were removed for
installation.
Wiring the Remote Module to the Mercury TCI
The Mercury Instruments Temperature Compensating Index (TCI) provides two Form-A volume pulse
outputs and one Form-B alarm output. These outputs are electronic switches. The first two pulse outputs are
configurable for compensated or uncompensated volume. The third output (Form-B) is for alarm output use
only.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
44
Electronic Instrument Installation
Connections to the three output pulse channels are completed using loose unterminated wires (the individual
wires from a cable) and gel-connectors. The TCI unit has six unterminated wires and six gel-connectors (Itron
part number CON-0023-001) to enable pulse connections to ancillary devices. Loose wires are located inside
the gray adapter plate behind the black strain relief fitting.
Adapter plate with black strain relief
Loose cable wires
The three switch contacts on the TCI PC board are MOSFET output type opto-isolators that provide high
voltage isolation between the sensitive processor components of the TCI board and the outside world.
Wire Color
Description
Function
Orange
Volume output channel A
Comp/uncomp volume pulse
Yellow
Volume output channel A
(configurable pulse timing)
White
Volume output channel B
Comp/uncomp volume pulse
Green
Volume Output channel B
(configurable pulse timing)
Brown
Alarm channel
Alarm event signal
Blue
Alarm channel
(Pulse timing)
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
45
Electronic Instrument Installation
To make TCI pulse connections
Note Connect one endpoint/channel to the alarm output if the endpoints are used on channels A and B.
Configuration for two endpoints connected to one TCI
Channel A
OWG-500x-504
TCI
White
Orange and brown
Red
Yellow
Blue
Blue (alarm)
Channel B
OWG-500x-504
TCI
White
White
Red
Green
Blue
White
1. Remove strain relief fitting by unscrewing from the gray adapter plate.
Note Do not remove the fitting's hex nut. Un-screw the entire fitting from the gray adapter plate. A tether
line is secured to the strain relief fitting. When the strain relief fitting is removed, the tether line pulls the
unterminated wires out of the adapter plate for access to the loose wires.
2. Loosen the strain relief fitting hex nut and remove the white plug from the center.
3. Place the strain relief fitting onto the field pulse cable.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
46
Electronic Instrument Installation
4. If the field pulse cable is smaller than a 0.2-inch diameter, install the rubber tube supplied with the TCI
onto the cable so the strain relief will clamp onto the tube after it is re-installed.
5. Connect the individual external pulse cable conductors to the un-terminated wires following
Configuration for two endpoints connected to one TCI at the beginning of these instructions. Insert one
un-terminated wire into an opening of a gel-connector (six gel-connectors were included with the TCI).
Insert the appropriate field cable wire into the other gel-connector opening.
6. Verify both wires are fully inserted into the gel-connector prior to crimping.
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection.
7. Insert the gel-connected wires into the threaded gray adapter plate hole.
8. Replace the strain relief and tighten until secure.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
47
Electronic Instrument Installation
Connecting the OpenWay Remote Mount Gas Module to the
Dresser ROOTS IMC/W2 or MC2 Cable
®
You may ship the Itron 2.4GZ OpenWay remote mount gas module directly to Dresser ROOTS® Meters for a
factory-installed cable. If you connect the module to the meter using an existing cable purchased from Dresser
ROOTS®, complete the following cable installation procedure.
Caution The purchased cable must have a mating connector compatible with the IMC/W2
or MC2 receptacle. Dresser ROOTS® cables may be wired in different configurations for
specific applications. If necessary, contact Dresser ROOTS® Meters for wiring diagrams for
your specific application.
To connect the 2.4GZ OpenWay remote mount gas module to the IMC/W2 or MC2 cable
1. Remove the backplate (4 screws) from the 2.4GZ remote module and expose the endpoint lead wires. The
backplate and screws will be re-installed on the endpoint module later in this procedure so store them
(temporarily) in a safe, secure place.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
48
Electronic Instrument Installation
2. Insert the lead wires from the 2.4GZ OpenWay remote mount gas module into new 3M gel connectors
(Itron part number CON-0023-001) together with the same colored lead wire from the meter cable (see the
wiring table below) and crimp using a 3M hand-held crimping tool.
Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping
gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply
pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity
silicone-based gel to flow. If the silicone gel flows out of the crimped connector, avoid touching the gel.
Gel flowing from the connector provides environmental protection for the connection.
Note Do not strip lead wire prior to inserting the wire in the gel connector.
IMC/W2 to Remote Endpoint Wire Table
IMC/W2 Wire
Remote endpoint wire
Red
Red
White
White
Blue
Blue
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
49
Electronic Instrument Installation
3. Dresser ROOTS® IMC/W2 and MC2 cables are typically delivered with a cable tie installed. If the meter
cable does not include a cable tie, install a tie to the cable just below the exposed colored lead wires on the
cable insulation. Remove the excess cable tie using a hand-held sidecutter pliers. The cable tie performs as
a cable strain relief to mitigate the risk of destructive tension on the lead wires.
4. Tuck the three gel connectors and cable tie inside the endpoint housing, as shown. Position the cable tie as
shown by the arrow in the position schematic below.
5. Install the 2.4GZ OpenWay remote mount gas module backplate using the four screws previously
removed from the endpoint and a Torx T-15 screwdriver.
Important Verify the cable tie and gel connectors are inside the endpoint housing and the cable extends
out of the slot in the backplate. Torque the backplate mounting screws to 9-12 inch-pounds.
TDC-0838-001 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Proprietary and Confidential
50

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2010:09:20 07:05:06-05:00
Creator                         : Microsoft® Office Word 2007
Modify Date                     : 2010:09:20 07:05:30-05:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2010:09:20 07:05:30-05:00
Creator Tool                    : Microsoft® Office Word 2007
Format                          : application/pdf
Document ID                     : uuid:4c067447-aa03-4f92-b5fe-e51cdb9ca565
Instance ID                     : uuid:6cb7992c-03a2-4b99-9fa3-d0f77006fbb2
Producer                        : Microsoft® Office Word 2007
Page Count                      : 56
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EO924GZRB

Navigation menu