Itron CCU100 AMR transceiver device reading AMR endpoints User Manual CCU 100 and Repeater 100 Installation Guide

Itron, Inc. AMR transceiver device reading AMR endpoints CCU 100 and Repeater 100 Installation Guide

Contents

Users Manual

    ChoiceConnect CCU 100 and Repeater 100 Installation Guide
  Identification CCU 100 and Repeater 100 Installation Guide  10/25/2010   TDC-0971-000  Copyright ©  2010 Itron, Inc. All rights reserved.  Confidentiality Notice The information contained herein is proprietary and confidential and is being provided subject to the condition that (i) it be held in confidence except to the extent required otherwise by law and (ii) it will be used only for the purposes described herein. Any third party that is given access to this information shall be similarly bound in writing.  Trademark Notice Itron is a registered trademark of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.  Suggestions If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com If you have questions or comments about the software or hardware product, contact Itron Technical Support:  Contact • Internet: www.itron.com • E-mail: support@itron.com • Phone: 1 877 487 6602  Compliance This device complies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following two conditions: • This device may not cause harmful interference.  • This device must accept any interference that may cause undesirable operation.  This device must be permanently mounted such that it retains a distance of 22.7 centimeters (9 inches) from all persons in order to comply with FCC RF exposure levels.  USA, FCC Class B - Part 15 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio or TV technician for help. This equipment has been tested and found to comply with the limits, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following conditions:  • This device may not cause interference. • This device must accept any interference that may cause undesired operation of the device.   CANADA, DOC ICES-003 This digital apparatus does not exceed the class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications, standard ICES-003. This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules.  Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Avis de conformite aux normes du Ministere des Communications du Canada. Le present appareil numerique n emet pas de bruits radioelectriques depassant les limites applicable aux appareils numeriques classe B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le Ministere des Communications du Canada, NMB-003.   Caution  ELECTROMAGNETIC COMPATIBILITY Use only approved accessories with this equipment. In general all cables must be high quality, shielded, and correctly terminated. Unapproved modifications or operation beyond or in conflict with these instructions for use, may void authorization by the authorities to operate the equipment.
  CCU 100 and Repeater 100 Installation Guide    iii  Proprietary and Confidential  Before You Begin........................................................................................................... v Documentation Conventions ........................................................................................................... v Related Documents ....................................................................................................................... vi Chapter 1 CCU/Repeater Basics ................................................................................. 1 CCU Configuration .........................................................................................................................1 CCU/Repeater Components ...........................................................................................................2 CCU/Repeater Module .........................................................................................................2 Remote GPS/WAN Antenna System ....................................................................................3 Endpoint Antenna .................................................................................................................5 Chapter 2 Planning a CCU/Repeater Installation ....................................................... 7 Installation Profiles .........................................................................................................................7 Siting CCUs/Repeaters ..................................................................................................................8 Propagation Study and CCU/Repeater Site Selection ...........................................................8 GPS and WAN Coverage .....................................................................................................8 AC Service Requirements ....................................................................................................9 External Ethernet Connections .............................................................................................9 Remote Endpoint Antenna Placement ..................................................................................9 Grounding the Antenna System .......................................................................................... 10 Lightning Arrestor ......................................................................................................................... 11 AC Mains Power .......................................................................................................................... 12 DC Mains Power .......................................................................................................................... 12 Materials Not Provided by Itron..................................................................................................... 13 Coaxial Cable ..................................................................................................................... 13 Antenna Connectors ........................................................................................................... 14 Mounting Hardware ............................................................................................................ 15 Chapter 3 Installing the CCU/Repeater ..................................................................... 17 Installation Overview .................................................................................................................... 17 Attaching the GPS/WAN Remote Antennas .................................................................................. 18 Attaching the Direct Mount Endpoint Antenna ............................................................................... 19 Attaching the CCU/Repeater ........................................................................................................ 21 Mounting Hardware ............................................................................................................ 21 Pipe Mount ......................................................................................................................... 22 Pole Mount ......................................................................................................................... 24 Wall Mount ......................................................................................................................... 26 Davit Arm Mount ................................................................................................................ 27 Connecting Cables ....................................................................................................................... 29 Installing the Battery ..................................................................................................................... 30 Providing Power ........................................................................................................................... 32 AC Mains Non-Remote Installation Diagram ................................................................................. 33 Tower Installation ......................................................................................................................... 33 Contents
Contents  iv   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  Tower Installation Overview ................................................................................................ 34 TCU Components............................................................................................................... 35 AC Tower Installation Diagram ........................................................................................... 38 Solar Powered Installation ............................................................................................................ 39 Solar Installation Overview ................................................................................................. 39 Solar Wiring Diagram ......................................................................................................... 40 Solar Installation Diagram................................................................................................... 41 Chapter 4 Battery Care and Replacement ................................................................ 43 Shipping Requirements ................................................................................................................ 43 Battery Storage and Charging ...................................................................................................... 44 Long-Term Storage ............................................................................................................ 44 State of Charge .................................................................................................................. 45 Charge the Battery ............................................................................................................. 45 Battery Service Life ...................................................................................................................... 46 Calendar Life ...................................................................................................................... 46 Preventative Maintenance .................................................................................................. 46 Replacing the Integrated Battery .................................................................................................. 47 Appendix A Detailed CCU/Repeater Specifications................................................. 49 CCU/Repeater Dimensions and Weight ........................................................................................ 49 Antenna Specifications - 100 ........................................................................................................ 50 Environmental Specifications ........................................................................................................ 51 Transmitter ................................................................................................................................... 51 CCU/Repeater Power Operating Range ....................................................................................... 51 Battery Pack................................................................................................................................. 52 Appendix B Status and Diagnostics ......................................................................... 53 Status Indicator ............................................................................................................................ 53 Diagnostic Port ............................................................................................................................. 54 Performing an Antenna Sweep Test ............................................................................................. 55 Index ............................................................................................................................. 57
  CCU 100 and Repeater 100 Installation Guide    v  Proprietary and Confidential    Important  Proper installation of the CCU/Repeater ensures trouble-free operation of the Itron Fixed Network system. The installation of both the collector and repeater must be done by professional installers.   Documentation Conventions This document uses the following conventions. Convention Example Key presses are in bold. Click OK to finish. Menu paths are in bold. Select Start > File > Save As.  Computer commands to be typed by the user are in a monospace font.  At the C: prompt, type cd itron/bin File names are in a monospace font. The data is uploaded to the upload.dat file Hypertext links are blue.  See the Copyright page for the contact information.   Note  A note indicates neutral or positive information that stresses or supplements important points of the main text. A note supplies information that may apply only in special cases.   Caution  A caution advises users that failure to take or avoid a specified action could result in a loss of data.    Warning  A warning advises users that failure to take or avoid a specified action could result in physical harm to the user or the hardware.    Tip  A tip helps users apply the techniques and procedures described in the text to their specific needs. A tip is not essential to the basic understanding of the text.   Before You Begin
Before You Begin    vi   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential   Related Documents For more information about CCUs/Repeaters and the Fixed Network, see the following:  • Collector Configuration Application v4.0 User Guide Fixed Network system administrators must use this document to properly configure CCU 100s before they are installed in the field.  • Network Collection Engine v4.0 User Guide • Motorola R56 Manual- Standards and Guidelines for Communication Sites Available from Motorola. This manual illustrates industry best practices for mounting and grounding antenna systems, and routing antenna cables into buildings. Use this guide as a reference when remotely mounting the endpoint antenna.
  CCU 100 and Repeater 100 Installation Guide    1  Proprietary and Confidential  The CCU 100 (also known as a cell control unit or collector) and the Repeater 100 are configurable for different installation locations, including: • On a water or communications tower. • On a pole (such as an electricity or light pole). • On a wall (indoor or outdoor). • On a pipe (between 2 and 3.5 inches in diameter). Integrated mounting and coupling brackets secure the device in high winds and under heavy ice loads.  The CCU 100 also supports an optional solar power kit.  Kits are sized by peak sun hour calculations which vary regionally across the country.  The kit includes solar panels and a large battery backup unit.  Size and weights vary by package type (based on peak sun hours). A CCU/Repeater consists of a number of components in a single weatherproof device. Electrical components are encased in a plastic enclosure that provides double insulation and a high level of safety for the installer.  Caution  Only authorized Itron personnel may open the CCU or Repeater. Unauthorized access to the module voids the warranty. Modification of this device voids the warranty and could cause non-compliance with FCC rules.   CCU Configuration A Fixed Network system administrator must configure each CCU 100 before it can be installed in the field. Verify with your supervisor or the system administrator that all CCUs are configured before you attempt to install them.  Please see the Collector Configuration Application v4.0 User Guide for more information.   CHAPTER 1  CCU/Repeater Basics
Chapter 1 CCU/Repeater Basics  2   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  CCU/Repeater Components The CCU 100 and Repeater 100 come in two basic configurations, non-remote and remote. The remote CCU/Repeater configuration replaces the internal antennas with external antenna connectors allowing both GPS and WAN antennas to be mounted in a remote location. In the case of the Repeater 100, only an external GPS connection is provided; a WAN modem is not present in a repeater. Both non-remote and remote configurations allow for remotely mounting the endpoint antenna by removing the antenna from the unit and attaching it to a remote antenna mounting plate. Since the CCU/Repeater may be installed in an outdoor environment, each component of the CCU/Repeater is weather-tight and can withstand wind requirements in excess of 100 MPH.   Note When determining the configuration of the CCU/Repeater, be sure to review the Itron CCU 100 Ordering Guide or the Itron Repeater 100 Ordering Guide for specific part numbers, cable lengths, and various options for the components.    CCU/Repeater Module The CCU/Repeater operates in the 902 to 928 MHz frequency range.  The CCU/Repeater case houses the backup battery, GPS receiver, optional WAN radio, processing board and endpoint radio. The antennas for the radios can be either internally connected or remotely connected, depending on the CCU/Repeater configuration.  Caution Only authorized Itron personnel may open the CCU/Repeater. Unauthorized access to the module voids the warranty.  An example of the remote CCU is shown below; the component connections are described in the following table.
 CCU/Repeater Components   CCU 100 and Repeater 100 Installation Guide    3  Proprietary and Confidential  Item Description 1 CCU/Repeater module Processes data from the antennas and relays it on to the Fixed Network Application Software. Only authorized Itron personnel may open this module.  2 Endpoint antenna This 900MHz antenna receives messages from and sends messages to endpoints and repeaters in the network. The connection for this antenna is a Type N female. 3 CCU/Repeater label Displays the collector identification number, model number, and other associated information. 4 Power connector Supplies power to the CCU/Repeater module. AC mains, DC, or solar power options are available. A three pin cable connects the CCU/Repeater to the mains supply. A two pin cable connects the CCU/Repeater to a DC supply. A five pin cable connects the CCU/Repeater to the solar system. 5 Remote GPS antenna connector  This female SMA connector is only on the remote CCU/Repeater. Use this connector when remotely mounting the GPS antenna.  6 Remote WAN antenna connector This female N connector is only on the remote CCU.  Use this connector when remotely mounting the WAN antenna.  7 Ethernet Connects the CCU/Repeater to the Ethernet backhaul. Also used to connect the CCU/Repeater to a router for initial collector setup. Mating weatherproof cables are available from Itron. These cables are sealed industrial ethernet circular IP67 connectors (CONEC) Note  A waterproof cap seals the Ethernet port from the elements in the field. Be sure to securely attach the cap once the collector is installed. 8 Ground lug The ground lug is provided on both the CCU and the Repeater and should be attached to earth ground according to local regulations. This ground helps protect the internal circuitry from high voltage transient events. The ground lug accepts AWG minimum wire size 14, and maximum wire size 4. 9 Status indicator This indicator displays the current operational status of the CCU/Repeater. See Status Indicator on page 53 for more information. * (Not shown) Battery door Removal of this door allows access to the replaceable battery pack.    Remote GPS/WAN Antenna System The remote CCU/Repeater configuration uses a GPS/WAN antenna kit that is connected to the CCU/Repeater by one or two separate pieces of coaxial cable.  • The WAN antenna is only connected in CCU installations that use a wide area network backhaul system.  • The GPS antenna is used in all deployments of this system.  The antennas must be installed in a location that allows reception of GPS and WAN signals.
Chapter 1 CCU/Repeater Basics  4   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  Itron recommends using a handheld GPS unit to verify that your GPS antenna mounting location can receive a signal from at least three satellites. If you are using a GPRS WAN backhaul, Itron recommends testing the GPRS antenna at your desired installation to ensure that GPRS service is available at that location. For more information, see GPS and WAN Coverage on page 8.  Caution  The GPS antenna must be oriented vertically when installed, and it must have an unobstructed view of the sky to properly receive a GPS signal.  The GPS/WAN antenna system is shown below.   Item Description 1 GPS antenna Receives GPS data from orbiting satellites. The cable connection on the bottom of this antenna is TNC Female.    2 Mounting bracket Attaches the antenna to your desired mounting location.  3 Antenna masts  Provide support for the GPS and WAN antennas. Cables for each antenna are routed through the masts. Clamps on the front of the mounting bracket secure the masts.  4 WAN antenna (CCU only) Provides the wide-area network (WAN) signal for the CCU. The Repeater does not use this antenna. The cable connection on the bottom of this antenna is N Female.
 CCU/Repeater Components   CCU 100 and Repeater 100 Installation Guide    5  Proprietary and Confidential   Endpoint Antenna The Endpoint antenna transmits and receives data messages from endpoints and repeaters in the network.  There are five possible antennas (two direct attached antennas and three remote antennas) that may be used for the endpoint radio link.   • A standard vertically or horizontally polarized antenna that is directly attached to the CCU/Repeater. • A standard vertically or horizontally polarized antenna that can be connected remotely, in place of the direct attached solution. • A high-gain vertically polarized remote antenna (8.15dBi) that is mounted remotely in place of the direct attached solution.  This antenna is only approved for the Tower CCU with proper cable loss to meet FCC regulations. • Remote antennas must be properly grounded during installation. When a remote antenna is used, a lightning arrestor is supplied for this purpose.  • The remote antenna's maximum allowed installation height above ground is 100 feet. Installation heights are determined by RF propagation studies by Itron systems engineering. If additional height is needed for the antenna, the tower version of the CCU is recommended. • Coaxial cable used to connect the endpoint antenna to the CCU/Receiver must be properly grounded. See Lightning Arrestor on page 11 for more information. • All coaxial cable connections must be properly weather-proofed per industry standards, unless otherwise specified. If the CCU/Repeater is installed indoors, only the connections located outside need to be weather-proofed.   When the CCU/Repeater is ordered with a remote antenna kit, some associated mounting hardware is included. Coaxial cables for the remote antennas are not included in the kit. These cables must be provided by the installer. Please see Coaxial Cable on page 13 for coaxial cable specifications. For more information, see: • Antenna Specifications on page 50 • Remote Endpoint Antenna Placement on page 9 • Grounding the Remote Antenna System on page 10
Chapter 1 CCU/Repeater Basics  6   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential
  CCU 100 and Repeater 100 Installation Guide    7  Proprietary and Confidential  This chapter describes how to prepare for a CCU/repeater installation.   Installation Profiles The CCU/Repeater can be installed in a variety of configurations and locations.  Depending on the installation location, the CCU or Repeater components may be installed all in the same place (as an integrated solution), or the antennas may be installed remotely from the CCU/Repeater (as a distributed solution).  For example, the CCU/Repeater can be installed at the base of a water tower, the GPS/WAN antenna system can be mounted up to 12 feet away for optimum reception, and the endpoint antenna can be placed at the top of the water tower.  The following profiles have been identified for CCU installation.  Location Description Utility pole The CCU/Repeater is installed on a utility pole. The CCU/Repeater should be mounted as high as possible on the pole for optimum reception.  Light pole The CCU/Repeater is installed on either a light pole or the davit arm that extends from the light pole. The CCU/Repeater should be mounted as high as possible on the pole for optimum reception.  Outdoor wall or pipe with remote antenna The CCU/Repeater is installed on an outside wall or pipe with the endpoint antenna remotely mounted to achieve the maximum elevation and reception. Indoor wall or pipe with remote antenna The CCU/Repeater is installed inside an equipment room with the endpoint antenna remotely (and externally) mounted to achieve maximum elevation and reception.  The WAN (or other digital cellular) and GPS antenna are remotely (and externally) mounted to provide acceptable coverage. Pipe The CCU/Repeater is secured to a pipe or fence railing  (from 2 to 3.5 inches in diameter). This type of installation typically occurs on the tops of water towers. For more information on these various profiles, as well as the Itron-recommended profile, see Chapter 3, Installing the CCU/Repeater on page 17. CHAPTER 2  Planning a CCU/Repeater Installation
Chapter 2 Planning a CCU/Repeater Installation  8   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential   Siting CCUs/Repeaters CCUs/Repeaters are installed in the field on a variety of surfaces, such as wooden or metal walls, metal pipes, fence railing, and utility poles. When determining where to place the CCU/Repeater, there are four primary considerations: • Siting for optimum RF reception. • Siting for optimum GPS and/or WAN reception.  • Availability of Ethernet connection (if required). • Availability of power connection. • Availability of a structure or location that can physically support the CCU/Repeater and its mounting hardware.    Caution  Always ensure that you have permission to install a CCU/Repeater at your chosen site prior to beginning installation.    Propagation Study and CCU/Repeater Site Selection Prior to installing a CCU/Repeater in the field, consult with Itron to perform a propagation study. This study:  • Evaluates the quantity and types of endpoints in the network. • Assesses environmental and geographical considerations related to CCU/Repeater installation.  • Optimizes CCU/Repeater placement in the network for the best possible reception. • Helps influence the physical and structural implications of mounting a CCU/Repeater to a given surface.  Once the propagation study is complete, you can determine exactly where to install CCUs/Repeaters and what they will be mounted to.   GPS and WAN Coverage CCUs/Repeaters must be installed in locations where a GPS signal is strong and consistent. If WAN is being used as the communications backhaul for the network, a strong and consistent WAN signal is required as well (for CCUs only). If the signal is too weak, or its availability fluctuates, the CCU/Repeater can not gather accurate date/time information or communicate with the Fixed Network software.  Itron recommends using a handheld GPS unit to verify that your CCU/Repeater or remote GPS antenna mounting location can receive a signal from at least three satellites. If you are using a GPRS WAN backhaul, Itron recommends testing the CCU or remote GPRS antenna at your desired installation to ensure that GPRS service is available at that location.
 Siting CCUs/Repeaters   CCU 100 and Repeater 100 Installation Guide    9  Proprietary and Confidential  To ensure the best possible signal, avoid installing the CCU/Repeater or the remote antennas in the following ways:  • Adjacent to or between tall buildings, signs, towers, or bridges. • Near swaying limbs, branches, or cables that could strike and damage the antenna.  • Between, beneath, or near highway overpasses, elevated train platforms, or tunnels. • Near objects or devices attached to the same pole. • Within 500 feet of high power radio frequency (RF) transmitters (such as paging transmitters, cellular transmitters, and municipal communications transmitters). • Near potential broadband sources of radiated RF energy (such as power line transformers, RADAR transmitters, cellular antennas, and neon or fluorescent signs). • Inside metal enclosures (the antenna will not communicate if surrounded by metal) or inside a building. The CCU/Repeater can be installed in a building or other metal enclosure, but the antennas must be installed remotely.    Warning!  Before installing a CCU/Repeater near or on the same pole as a transformer, consult the National Electrical Safety Code (NESC), local utilities, municipalities, and cable and telephone companies for recommended distances from transformers and power lines.   AC Service Requirements A 90 to 265 VAC 10A power source is required at the installation site for the CCU/Repeater, unless you are using the DC CCU/Repeater or the solar CCU/Repeater. For more information on these options, see Mains Power Installation Profiles on page 12 or Solar Power Installation Profiles on page 39.   External Ethernet Connections If the Ethernet connection is used as the communications backhaul, the CCU installation site must have Ethernet access. Also, be sure to use weatherproof cables in this type of installation.   Caution  When using Ethernet as the communications backhaul, the CCU must be identified as Ethernet-based when performing Initial Collector Setup (ICS). Failure to do so prohibits the CCU from communicating with the Network Collection Engine.     Remote Endpoint Antenna Placement Antenna placement is one of the most important factors in determining your overall system performance. Careful consideration must be given to proper antenna placement. Follow the general guidelines below when determining the ideal location for a remote-mounted endpoint antenna.     • The antenna needs to be mounted in a location where it has a clear unobstructed 360 degree view of the horizon.
Chapter 2 Planning a CCU/Repeater Installation  10   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  • The antenna receives and transmits in all directions. Any objects such as building walls, nearby metal surfaces or other obstructions will interfere with the proper operation of the antenna.   • Do not mount the antenna near existing RF radiating antennas. If existing RF radiators are nearby, the horizontal separation distance to the radiator must be a minimum of 100 feet and/or 10 feet of vertical separation. In instances where nearby RF radiators are present, conduct an intermodulation interference study to evaluate the potential for interference and any effects it may have on system performance. Consult with your Itron systems engineer for more information.   • When mounting the antenna, evaluate nearby buildings and the effect they may have on system performance.  Mounting on a rooftop, where nearby buildings are higher than the installation location, is not an ideal location for the antenna.   • Height is preferred for optimal performance. Mount the antenna as high as possible, but no higher than 100 feet. If the antenna is going to be more than 100 feet above the CCU, you should use a Tower CCU 100.  A side arm antenna installation must be done if the endpoint antenna is mounted where it does not have an unobstructed 360-degree view. Refer to the following guidelines for a side arm antenna installation. • For the endpoint antenna, the minimum standoff distance is 24 inches, where the interfering structural members are four inches or less in diameter and spaced more than eight feet apart.  • For structural members between 4 and 10 inches in diameter, a sliding scale of 2 to 5 feet is to be used. (For example, a 24 inch standoff at 4 inch diameter to a 60 inch standoff at 10 inch member diameter.)   • When local site conditions do not meet this requirement (for example, when structural members are greater than 10 inches in diameter and/or members are less than 8 feet apart), additional analysis is required to determine the effect on the pattern. Adjustment to the propagation model may be needed. Provide Itron with the diameter of the structural members and the distance between them so that a thorough analysis can be performed. If the structure covers more than 30 degrees of the pattern (as measured from the proposed standoff distance), the site is considered as a 180 degree sector from a systems design perspective and another CCU/Repeater and antenna need to be installed on the opposite side of the structure.  Grounding the Antenna System To minimize the potential for a lightning event, it is essential that the remote antenna system be properly grounded. Proper grounding prevents the accumulation of static charges on the antenna system and also provides a direct discharge to ground for any acquired charges. All grounding materials and procedures must meet or exceed local codes. Use coaxial grounding kits recommended by the coaxial cable manufacturer.  Warning  Under no circumstances should the antenna grounding wires be run inside a building.  Always install ground bars and grounding material on the exterior of buildings.
 Lightning Arrestor   CCU 100 and Repeater 100 Installation Guide    11  Proprietary and Confidential  The recommended procedure for grounding the antenna system is as follows:  • Mount a copper ground bar near the antenna. This is the top ground bar.  • Mount a second copper ground bar near the CCU/Repeater. This is the bottom ground bar.  • Connect the two ground bars with a #6 gauge green jacketed stranded wire or a #2 solid copper wire.  • Ground the antenna mount and the top coaxial ground kit to the top ground bar.  • Ground the bottom coaxial ground kit and the lightning arrestor to the bottom ground bar.  • Connect the bottom ground bar to one or more earth ground rods.  • All ground wires should be connected straight to ground, with no right angle turns or sharp bends in the wires.  • Install ground leads on coaxial grounding kits without loops or bends and install grounding kits in the proper orientation per the manufacturer's specifications.   Lightning Arrestor A lightning arrestor (or surge protector) capable of withstanding multiple lightning strikes should be installed when using a remote mount antenna. This helps protect the CCU/Repeater in the event of a lightning strike.  The lightning arrestor is fitted to the coaxial antenna cable at the SURGE end and the RF jumper cable that connects to the CCU/Repeater module at the PROTECTED end. It includes a bulkhead connector interface that mounts to a ground plate with a washer and nut. The arrestor is also furnished with a ground lug, if your installation does not have provisions for a ground plate. The ground lug on the arrestor is designed for #2AWG solid or stranded wire. The ground wire must be crimped to this lug, never soldered.  Caution  The lightning arrestor must be connected to an earth-ground.
Chapter 2 Planning a CCU/Repeater Installation  12   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  The top and bottom ends of the coaxial cable attached to the tower should be electrically grounded with kits for lightning protection. The antenna input connection cannot serve as the top ground point. For cable lengths in excess of 200 feet, ground the vertical cable run at the midpoint and then each additional 200 feet.   Note  The installer must supply any mounting brackets and cable-management clips to secure the coaxial cable to the tower or structure, when using a remote mount antenna. Consult your cable manufacturer for specifications on proper clips and grounding kits. Conduit clamps and tie wraps are not satisfactory methods for securing coaxial cables. For remote installation with a high gain antenna, a lightning arrestor is supplied by Itron in the CCU 100/Repeater 100 kit materials.   AC Mains Power The AC mains wiring to the CCU/Repeater utilizes a three conductor cable. This cable can be terminated with either a NEMA L5-15 (125V, 15A) or a NEMA L6-15 (250V, 15A) locking plug in order to meet local electrical codes. The CCU should be powered by a dedicated 10A circuit. The CCU/Repeater should not be connected to a circuit protected by a GFCI breaker. Power wiring on the Itron supplied power cable follows conventional color coding for AC wiring: Green/Ground, White/Neutral, Black/Hot.  DC Mains Power The DC wiring to the CCU/Repeater utilizes a two conductor cable. The CCU should be connected to a 10A DC circuit breaker or fuse. Wiring of the Itron supplied two conductor cable is accomplished by attaching the red wire to a +12V source and attaching the black wire to ground.
 Materials Not Provided by Itron   CCU 100 and Repeater 100 Installation Guide    13  Proprietary and Confidential   Materials Not Provided by Itron The following materials are not provided by Itron in the CCU/Repeater kit, but are required for installation.  Please acquire these items prior to beginning an installation.  • Coaxial cable on page 13 • Connectors on page 14 • Mounting hardware on page 14  Coaxial Cable When remote mounting the antennas, coaxial cable must be supplied to connect the antenna to the CCU/Repeater. The proper size of cable is dependent on total cable length and frequency. Coaxial cable also requires proper hoisting grips, ground kits, connectors, jumpers, hangers, and weather proofing material. Coaxial cable and accessories are not provided by Itron. Coaxial cable systems must be installed according to the manufacturer's specifications. Itron recommends using qualified radio installation contractors to install the remote antenna system. See Motorola R56 guidelines for recommended practices on cable installation. Cable lengths should not exceed 12 feet, except when used with the high-gain antenna. Remote Mount Endpoint Antenna on a Standard CCU/Repeater When selecting cable for the remote mount unity gain endpoint antenna on the standard (non-tower) CCU/Repeater, total cable loss cannot exceed 1.5 dB to maintain system performance. Allow 0.1 dB loss for each connector. Remote Mount High Gain (8.15 dBi) Endpointed Antenna on a Tower CCU When selecting cable for the remote mount high gain (8.15 dBi) endpoint antenna on the tower CCU, total calculated loss between the tower cabinet and the antenna must be greater than 2 dB, but less than 3.5 dB.   Warning  This 2 dB loss is required to prevent exceeding the maximum EIRP, as set by the FCC. Allow 0.1 dB loss for each connector. If required, a 1 dB attenuator (similar to the Pasternack PE7002-1) may be used to attain the desired power at the antenna.
Chapter 2 Planning a CCU/Repeater Installation  14   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  Antenna Sweep Test After remote antenna installation perform an antenna system sweep test and verify that VSWR (voltage standing wave ratio) does not exceed 1.5:1. For more information, see Perform an Antenna Sweep Test on page 55.    Caution  All coaxial cable used to connect an antenna to the CCU/Repeater must be properly grounded at the top and bottom of the coaxial line. Additionally, any cable lengths of 200 feet or greater must be grounded each 100 feet. See Lightning Arrestor on page 11 for more information. The following table lists the possible coaxial cable lengths and specifications.  Total Coaxial length Coax specification  0-120 ft. 121-200 ft. (high-gain antenna only) 201-250 ft. (high-gain antenna only) Standard black jacket cable AVA5-50 AVA6-50 AVA7-50 Optional fire retardant cable AVA5RK-50 AVA6RK-50 AVA7RK-50 Cable diameter (nominal) 7/8 in.   1-1/4 in.  1-5/8 in. Cable weight (lb./ft.)  0.33 0.46 0.70 Minimum bend radius 10 in. 8 in. 15 in. Cable attenuation @ 915 MHz ~ 1.2 dB/100 ft. ~ 0.84 dB/100 ft. ~0.70 dB/100 ft.   Antenna Connectors Connectors for the endpoint and WAN antenna cables need to be male Type N connectors and must be sized according to the type of coaxial cable used. The GPS cable requires TNC male and SMA male connectors. These connectors are available from a variety of manufacturers.   Important  All coaxial cable connections must be properly weather-proofed per industry standards unless otherwise specified. If the CCU/Repeater is installed indoors, only the connections located outside need to be weather-proofed.
 Materials Not Provided by Itron   CCU 100 and Repeater 100 Installation Guide    15  Proprietary and Confidential   Mounting Hardware Depending on your installation location and configuration, the following mounting hardware must be supplied by the installer to properly attach the CCU/Repeater to the mounting surface.    Caution  Since each installation is unique, you must ensure that the mounting hardware you supply can securely support the CCU/Repeater. The CCU/Repeater (minus attachment hardware) weighs 7 pounds. Itron recommends consulting with a qualified engineer to verify load requirements and safety issues. Also, be sure to check and comply with local codes when installing the CCU/Repeater.     Profile Mounting surface Suggested hardware/sizing Utility pole Wood or steel pole  High-strength stainless steel straps Light pole Steel light pole High-strength stainless steel straps Outdoor wall or pole with remote antenna Concrete, wood, or steel wall  1/4 inch-20 lag screws or 1/4 inch-20 molly bolts Wood or steel pole High-strength stainless steel straps Indoor wall or pole with remote antenna  Concrete, wood, sheetrock, or steel wall  1/4 inch-20 lag screws or 1/4 inch-20 molly bolts Wood or steel pole High-strength stainless steel straps Pipe 2.5 inch to 3.5 inch galvanized steel pipe Two pipe mount brackets for pipes up to 3.5 inches in diameter, supplied by Itron (part number FAB-0192-001, two brackets are required for each CCU/Repeater).
Chapter 2 Planning a CCU/Repeater Installation  16   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential
  CCU 100 and Repeater 100 Installation Guide    17  Proprietary and Confidential  This chapter shows you how to install a CCU/Repeater in the field, using the Itron-recommended installation method.  The CCU/Repeater can be installed in a variety of ways. Several different CCU/Repeater installation profiles are shown in this chapter, for both mains powered and solar powered CCU/Repeaters.   Warning  Before installing a CCU/Repeater, ensure that the selected location can support the weight of the CCU/Repeater and mounting hardware. A thorough structural analysis should be performed by a qualified engineer at your desired location prior to installation. Itron is not responsible for improper installations or for installations at a site that cannot adequately support the CCU/Repeater.     Installation Overview The following section shows you how to install a CCU/Repeater using the Itron-recommended profile. This profile calls for the CCU/Repeater to be mounted to a 2 inch diameter vertical pipe. A 110V source supplies mains power to the CCU/Repeater.   Caution  Prior to installing a CCU in the field, be sure to configure it as described in the Collector Configuration Application v4.0 User Guide. A CCU cannot be configured after it has been installed in the field. Repeaters do not require pre-installation configuration. There are several main steps to perform. Each step is described in more detail in the following sections.  1. Attach the remote antennas on page 18 (if necessary). 2. Attach the direct mount endpoint antenna on page 19 (if necessary). 3. Attach the CCU/Repeater to the mounting surface on page 21. 4. Connect the cables on page 29. 5. Install the battery on page 30. Caution  Do not move or transport the CCU without first disconnecting the battery.  Moving or tilting a CCU with the battery connected may cause the CCU to reset to the factory image. 6. Provide power on page 32. 7. Perform an antenna sweep test on page 55.  CHAPTER 3  Installing the CCU/Repeater
Chapter 3 Installing the CCU/Repeater  18   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  Attaching the GPS/WAN Remote Antennas The GPS and WAN remote antennas can be attached to pipes, poles, walls, and davit arms. A typical pole mount assembly is shown below.      To attach the GPS/WAN remote antennas • For step-by-step assembly instructions, see the GPS/WAN Remote Antenna Mounting Kit Assembly Guide included with the GPS/WAN Remote Antenna Mounting Kit.
 Attaching the Direct Mount Endpoint Antenna   CCU 100 and Repeater 100 Installation Guide    19  Proprietary and Confidential   Attaching the Direct Mount Endpoint Antenna Attach the direct mount endpoint antenna before mounting the CCU/Repeater in its permanent location.  To attach the direct mount endpoint antenna 1. Screw the antenna onto the top of the CCU/Repeater. Be careful not to cross-thread the connectors. Do not over tighten.  2. Slide the antenna sleeve over the antenna, ensuring that the front of the antenna sleeve (1) is to the front of the CCU/Repeater.
Chapter 3 Installing the CCU/Repeater  20   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  3. Using the included screws, washers, and lock washers, screw the antenna sleeve to the top of the CCU/Repeater. Tighten the screws to 5 to 6 in/lbs.
 Attaching the CCU/Repeater   CCU 100 and Repeater 100 Installation Guide    21  Proprietary and Confidential   Attaching the CCU/Repeater The CCU/Repeater may be attached to a variety of surfaces. See the following sections for diagrams showing some of the possible configurations. • Pipe mount on page 22 • Pole mount on page 24 • Wall mount on page 26 • Davit arm mount on page 27  Mounting Hardware This set of hardware can be adapted to mount the CCU/Repeater in many different locations. For pole or pipe mounts, the mounting hardware consists of a mounting plate, two brackets, four bolts, and a set screw.   For a wall mount, use two metal brackets (not shown below), four mounting bolts, nuts, and lock washers to prepare the CCU for mounting. Itron does not supply the hardware necessary to mount the CCU wall mounting brackets to the wall. An integrated mounting support on the back of the CCU/Repeater enclosure slides into the slot in the center of the mounting bracket.  A set screw locks the CCU/Repeater to the mounting bracket.  Orientation of the enclosure may be adjusted +/- 16 degrees horizontal to compensate for different angles.
Chapter 3 Installing the CCU/Repeater  22   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential   Pipe Mount The image below illustrates a typical vertical pipe installation.  The CCU/Repeater may also be attached to a horizontal pipe. In this case the CCU/Repeater mounting plate is attached to the vertical pipe with the mounting brackets and the CCU/Repeater enclosure is secured to the mounting plate.  The power cable is connected to the available AC service with either the un-terminated pigtail power cable or the grounded outlet plug power cable (optional).   To mount the CCU/Repeater on a pipe 1. Using the two mounting brackets and four bolts, attach the mounting plate to the pipe.
 Attaching the CCU/Repeater   CCU 100 and Repeater 100 Installation Guide    23  Proprietary and Confidential  2. Insert the mounting disc into the mounting plate keyhole.  3. Using the provided set screws, secure the CCU to the mounting plate in the upright position.
Chapter 3 Installing the CCU/Repeater  24   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  Pole Mount If the vertical pipe or pole exceeds 6.75 inches in diameter, metal bands may be used in place of the mounting brackets to secure the mounting plate to the pipe or pole.  Two sets of slots (1.5 in. long) on the mounting plate are provided for the metal bands.  If the pole is large in diameter, Itron recommends that the endpoint antenna be remote mounted to achieve optimum RF performance.    To mount the CCU/Repeater on a pole 1. Insert the mounting disc (on the back of the CCU) into the mounting plate keyhole.
 Attaching the CCU/Repeater   CCU 100 and Repeater 100 Installation Guide    25  Proprietary and Confidential  2. Using the provided set screws, secure the CCU to the mounting plate in the upright position.  3. Using two steel straps, attach the mounting plate to the pole.
Chapter 3 Installing the CCU/Repeater  26   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential   Wall Mount The following image illustrates a wall mount installation.  In this scenario two brackets are secured to the flat wall surface and the CCU/Repeater is bolted to the brackets.  The power cable may be connected to a standard outlet or other available AC service.  It may be necessary to use the remote antenna kit to achieve optimum RF performance and GPS coverage if mounted indoors or if the wall obstructs the desired RF path.   To mount the CCU/Repeater on a wall 1. Using four bolts, secure the CCU to the two wall mounting brackets. 2. Using four appropriate screws or bolts (not provided by Itron), attach the mounting brackets to the wall.
 Attaching the CCU/Repeater   CCU 100 and Repeater 100 Installation Guide    27  Proprietary and Confidential  Davit Arm Mount The figure below illustrates a typical utility pole or street light pole installation.  The CCU/Repeater is mounted on a davit arm or the street light arm.  Two types of power connections are typical.  A photocell adapter cable may be used when the CCU/Repeater is mounted on a street light arm.  This cable plugs into the photocell sensor of the street light.  If the CCU/Repeater is mounted on a davit arm with no street light, the un-terminated pigtail power cable may be connected to the AC service at the pole.     To mount the CCU/Repeater on a davit arm 1. Using the two mounting brackets and four bolts, attach the mounting plate to the davit arm.
Chapter 3 Installing the CCU/Repeater  28   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  2. Insert the mounting disc into the mounting plate keyhole. The following photos are shown off the davit arm for clarity.  3. Using the provided set screws, secure the CCU to the mounting plate in the upright position.
 Connecting Cables   CCU 100 and Repeater 100 Installation Guide    29  Proprietary and Confidential   Connecting Cables Connect the remote antenna cables (if needed), Ethernet cable (if needed), and grounding wire.  Because of the variable requirements for cable length, cables are not provided by Itron.  Important  All coaxial cable connections must be properly weather-proofed per industry standards unless otherwise specified. If the CCU/Repeater is installed indoors, only the connections located outside need to be weather-proofed.    To connect cables 1. The GPS cable has an SMA connector on one end and a TNC connector on the other end. Connect the SMA connector end of the GPS antenna cable to the CCU/Repeater. Connect the TNC end of the GPS cable to the remote GPS antenna.   2. The WAN cable has a TNC connector on one end and an N connector on the other end. Connect the N connector end of the WAN antenna cable to the CCU. Connect the TNC end of the cable to the remote WAN antenna.  Note  Repeaters do not use WAN antennas.
Chapter 3 Installing the CCU/Repeater  30   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  3. If you are using a remote endpoint antenna, attach the endpoint antenna cable to the connector on the top of the CCU/Repeater. Important  Using weatherproof tape, wrap the remote endpoint antenna connection on the top of the CCU/Repeater.  Wrap from the CCU/Repeater up to the antenna cable.  4. If you are using an Ethernet backhaul, attach the Ethernet cable ensuring the weather-tight connector is properly secured. If the Ethernet connection is not used, secure the weatherproof cap. 5. The grounding lug should be attached to earth ground according to local codes.  Installing the Battery To install the battery 1. Remove the battery cover by loosening the four screws securing it.  These are captive screws and do not need to be fully removed from the battery cover.
 Installing the Battery   CCU 100 and Repeater 100 Installation Guide    31  Proprietary and Confidential  2. Plug in the four pin battery wiring harness. The harness should snap into place, providing a secure connection.   3. Slide the battery into the battery compartment.   4. Replace the battery compartment cover, and torque the screws to 6 inch-pounds.
Chapter 3 Installing the CCU/Repeater  32   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential   Providing Power The final step of the CCU/Repeater installation is to provide power to the CCU. Depending on the CCU/Repeater model, either a two pin cable (DC), three pin cable (AC), or a five pin cable (solar) is required.   Caution  Do not move or tilt the CCU for one minute after connecting power. Moving or tilting a CCU too soon after connecting power may cause it to reset to the factory image.    To provide power 1. Plug the appropriate cable in to the CCU/Repeater.  Note  The connector is keyed so that the cable can connect in only one orientation.  2. Securely fasten the power cable to the CCU/Repeater by tightening the retaining nut on the cable.
 AC Mains Non-Remote Installation Diagram   CCU 100 and Repeater 100 Installation Guide    33  Proprietary and Confidential  AC Mains Non-Remote Installation Diagram   Tower Installation   Warning  Before installing a Tower CCU, ensure that the selected location can support the weight of the Tower CCU and mounting hardware. A thorough structural analysis should be performed by a qualified engineer at your desired location prior to installation. Itron is not responsible for improper installations or for installations at a site that cannot adequately support the Tower CCU.   All coaxial cable connections must be properly weather-proofed per industry standards unless otherwise specified. This includes any connections for the antennas and the Tower CCU. If the Tower CCU is installed indoors, only the connections located outside need to be weather-proofed.   Important  To prevent exceeding the maximum EIRP set by the FCC, there must be at least 2 dB of loss between the antenna connector at the base of the tower cabinet and the high gain endpoint antenna. Do not exceed 3.5 dB of loss to maintain system performance. Only use the Itron approved high gain antenna. Because of the size and weight of the Tower CCU, Itron recommends that more than one person be present for the installation. See Antenna Specifications on page 49 for more information.
Chapter 3 Installing the CCU/Repeater  34   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential    Tower Installation Overview The Tower CCU 100 (TCU)  installation differs significantly from other CCU 100 installation profiles in that the CCU 100 is installed within a cabinet enclosure at the base of a radio tower and all of the antennas are mounted remotely. The standard cabinet protects the hardware from adverse environmental conditions and provides easy access for servicing the CCU and its related components. The TCU box comes preassembled except for the CCU.  The CCU must have the ICS procedure performed prior to installing the CCU in the TCU box.
 Tower Installation   CCU 100 and Repeater 100 Installation Guide    35  Proprietary and Confidential  TCU Components  1 RF Filter 2 Battery 3 Surge protection devices (SPDs), receptacle, terminal blocks 4 CCU mounting plate 5 Roxtec™ block 6 Wiring diagram 7 Document holder 8 Air filters  There are two air filters, one shown at (8) and another behind the fan (9). 9 Fan
Chapter 3 Installing the CCU/Repeater  36   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential   To assemble the Tower CCU 100 1. Attach CCU to CCU mounting plate. a. Insert the CCU mounting disc into the mounting plate keyhole. b. Slide the CCU down until you feel it click into place. 2. Connect cable from CCU to RF filter.  3. Connect ground wire to CCU.  4. (optional) Connect the Ethernet cable to the CCU and the top of  the 10/100 BT SPD.  Feed the external Ethernet cable through the Roxtec block and connect it to the bottom of the 10/100 BT SPD. Instructions for using a Roxtec Block are supplied in the TCU cabinet.
 Tower Installation   CCU 100 and Repeater 100 Installation Guide    37  Proprietary and Confidential  5. Connect the battery to the connector on the battery door of the CCU. The battery door connection is only present on CCUs designed for TCU installations.  6. Feed the GPS and WAN (if required) antenna cables through the Roxtec block and connect them to the CCU.  7. Connect the power cable to the CCU.  8. See Attaching the Remote Antennas on page 18 for instructions on installing the antennas. 9. Connect power to the cabinet. See the wiring diagram on the inside of the cabinet door.
Chapter 3 Installing the CCU/Repeater  38   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  AC Tower Installation Diagram
 Solar Powered Installation   CCU 100 and Repeater 100 Installation Guide    39  Proprietary and Confidential   Solar Powered Installation All coaxial cable connections must be properly weather-proofed per industry standards unless otherwise specified. This includes any connections for the antennas and the CCU/Repeater. If the CCU/Repeater is installed indoors, only the connections located outside must be weather-proofed.  Warning  Before installing a CCU/Repeater, ensure that the selected location can support the weight of the CCU/Repeater, mounting hardware, solar panels, and batteries. A thorough structural analysis should be performed by a qualified engineer at your desired location prior to installation. Itron is not responsible for improper installations or for installations at a site that cannot adequately support the CCU/Repeater.  Because of the size and weight of the solar system, Itron recommends that more than one person be present for the installation.  Solar Installation Overview The Solar CCU/Repeater installation differs slightly from other CCU 100 installation profiles in that the power comes from a separate cabinet enclosure which houses the solar controller and batteries.  The Solar CCU/Repeater is mounted like other CCU/Repeaters, but the power comes from the solar cabinet which houses the solar controller and batteries. The picture below shows a solar tower installation.
Chapter 3 Installing the CCU/Repeater  40   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  Solar Wiring Diagram The diagram below illustrates how a solar panel system must be wired to connect to the CCU/Repeater. This enclosure is pre-wired. You are required to connect only the power and the ground.    To assemble the Solar CCU 100 1. Mount the solar panels and battery box as described in the Installation, Operation, and Maintenance Manual supplied with the solar system. 2. Wire the five conductor power cable to the solar cabinet, as shown in the Solar Wiring Diagram on page 40. Use the watertight grommet supplied with the solar cabinet. 3. Mount the CCU/Repeater in the desired location. Note  The power cable from the solar battery box to the CCU/Repeater should be less than 12 feet long. 4. Connect ground wire to CCU. 5. If required, connect the antenna and Ethernet cables to the CCU/Repeater. 6. Connect the battery to the CCU. 7. Connect the power cable to the CCU. 8. See Attaching the Remote Antennas on page 18 for instructions on installing the antennas.
 Solar Powered Installation   CCU 100 and Repeater 100 Installation Guide    41  Proprietary and Confidential  Solar Installation Diagram The diagram below shows a typical solar powered installation.
Chapter 3 Installing the CCU/Repeater  42   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential
  CCU 100 and Repeater 100 Installation Guide    43  Proprietary and Confidential  In this chapter, you will learn how to perform field maintenance on the CCU/Repeater battery. With some routine care, the batteries used by CCUs/Repeaters will perform at optimal levels for several years.  The following sections show you how to store and charge spare CCU/Repeater batteries, as well as how to replace a CCU/Repeater battery in the field.   Shipping Requirements   Warning!  Electrical fire hazard—protect against shorting. Terminals can short circuit and cause a fire if not insulated during shipping.  Requirements for shipping batteries:  • Batteries must be labeled "NONSPILLABLE" during shipping. Follow all federal shipping regulations. See CFR 49 Parts 171 through 180, available online at www.gpoaccess.gov • Batteries must have short circuit protection during shipping. Exposed terminals, connectors, or lead wires must be insulated with a durable inert material to prevent exposure during shipping. Failure to comply with these requirements can cause a fire during shipping and handling.    CHAPTER 4  Battery Care and Replacement
Chapter 4 Battery Care and Replacement  44   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential   Battery Storage and Charging To ensure maximum lifespan and efficiency from your CCU/Repeater batteries, Itron recommends the following storage and maintenance procedures.   Long-Term Storage Batteries may be stored for up to two years at room temperature (25°C or 77°F), and then may be recharged with no loss in cell reliability or performance capabilities. The example storage time versus temperature chart below is a plot of maximum storage time as a function of storage temperature. This curve shows the maximum number of days at any given temperature, from 10°C (50°F) to 65°C (149°F), for the battery to discharge from a fully charged state of about 6.42 volts (2.14 volts per cell) down to a zero charge state of 5.79 volts or (1.93 volts per cell). The battery should not be allowed to discharge below 5.79 volts because of the danger of damaging the performance characteristics of the battery permanently.  When batteries are stored at or near 25°C (77°F) it is recommend to conduct an open circuit voltage (OCV) audit every six months and recharge when OCV readings approach 6 volts (2.00 volts per cell). If storage temperatures are significantly higher than 25°C (77°F), even for short durations, the frequency of OCV audits must increase. It is important to recognize that the self-discharge rate of the battery is non-linear. The rate of self-discharge changes as the state of charge (SOC) of the battery changes. The time taken for a battery to discharge from a 100% SOC to 90% SOC is different from the time it takes to self-discharge from a 20% SOC to a 10% SOC.
 Battery Storage and Charging   CCU 100 and Repeater 100 Installation Guide    45  Proprietary and Confidential  State of Charge The state of charge (SOC) of the battery can be approximated by using the curve shown in the chart below. This curve is accurate to within 20% of the true SOC of the cell under consideration, if it has not been charged or discharged within the past 24 hours. The curve is accurate to within 5% if the cell has not seen any activity, charge or discharge, for the past five days.   Charge the Battery You can charge spare CCU/Repeater batteries individually or in groups to save time.  When charging batteries, there are several items you need:  • Power Sonic PSC-124000A-C charger • Molex 39-01-4046 connector • CCU/Repeater batteries The recommended method for charging the batteries is to utilize the Power Sonic PSC-124000A-C charger. The Power Sonic charger needs to be modified so that it can be plugged directly into the battery. This is done by retrofitting the output of the charger to a Molex 39-01-4046 connector with the red wire going to pin one and the black wire going to pin two of the connector. Follow the instructions that come with the charger for correct operation. After charging, the battery should be removed from the charger for at least 24 hours. After this time the open circuit voltage should be measured to verify that it is at or above 6.4 volts.   Note  Batteries in storage need to be charged routinely for maximum shelf life. For more information, see Long Term Storage on page 44.
Chapter 4 Battery Care and Replacement  46   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  Battery Service Life All batteries have extremely variable service life, depending upon the type of cycle, environment, and charge to which the cell or battery is subjected during its life. There are two basic types of service life: cycle life and calendar life. The battery in the CCU/Repeater is called in to service only during power outages, so in this case only calendar (or float) life is applicable.   Calendar Life The design calendar (or float) life of the battery is up to eight to ten years at room temperature (25°C/77°F) and under proper charging conditions.  This design life has been confirmed by the use of accelerated testing methods that are widely accepted by both manufacturers and users of sealed-lead batteries. High temperatures are used to accelerate the aging process of the battery under test. The float life of a cell is cut in half for roughly every 8°C (14.4°F) rise in ambient temperature. The example below shows the relationship between ambient temperature and float life for batteries that have a float life of ten years at 25°C (77°F).  A ten year battery lasts for five years at 33°C (91.4°F) and only 2½ years at 41°C (105.8°F).  Preventative Maintenance Itron recommends a preventative maintenance cycle of a two-year replacement in extreme environments (average temperatures greater than 110°F/44°C), or five years in non-extreme environments (average temperatures less then 90°F/31°C).
 Replacing the Integrated Battery   CCU 100 and Repeater 100 Installation Guide    47  Proprietary and Confidential  Replacing the Integrated Battery The following procedure shows you how to replace the integrated battery once it has been installed in the field.    Warning  Risk of explosion if battery is replaced by an incorrect type. Always replace with Itron part number BAT-0045-001.  For information on battery disposal or recycling, contact EnerSys at 1.800.363.7797 or recycling@enersys.com.  To replace the battery 1. Remove the battery compartment cover by loosening the four screws securing it.  2. Slide the battery out of the battery compartment.  3. Carefully, disconnect the four pin connector. 4. Connect the new battery's four pin connector. 5. Slide the new battery into the battery compartment. 6. Replace the battery compartment cover, and torque the screws to 6 inch-pounds.
Chapter 4 Battery Care and Replacement  48   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential
  CCU 100 and Repeater 100 Installation Guide    49  Proprietary and Confidential  CCU/Repeater Dimensions and Weight Weight is shown in pounds and dimensions are shown in inches. Component Weight CCU/Repeater 7 lbs AC tower unit 76 lbs Remote GPS/WAN antenna system 6 lbs Remote 900 MHz antenna system 3.5 lbs 900 MHz antenna (standard, unity gain) 1 lb Pole mounting kit 3 lbs Wall mounting kit 2 lbs   APPENDIX A  Detailed CCU/Repeater Specifications
Appendix A Detailed CCU/Repeater Specifications  50   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  Antenna Specifications - 100 Specifications for the standard (unity gain) endpoint antenna and high gain antenna are shown in the following table.   Important  All coaxial cable connections must be properly weather-proofed per industry standards unless otherwise specified. This includes any connections for the antennas and the CCU/Repeater components. If the CCU/Repeater is installed indoors, only the connections located outside need to be weather-proofed.  This device has been designed to operate with the antennas listed below that have a maximum gain of 8.15 dBi. Antennas not included in this list or having a gain greater than 8.15 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Specification Vertically polarized High gain (8.15dBi) Horizontally polarized Part number MSE-0316-001 MSE-0373-001 MSE-0303-001 Gain 0 dBd (2.15 dBi) 6.0 dBd (8.15 dBi) 2 dBd (4.15dBi) Horizontal beamwidth Omnidirectional Omnidirectional Omnidirectional Vertical beamwidth  -3dB minimum, =/- 40 degrees from horizontal 17 degrees 45 degrees Electrical downtilt available 0 degrees 0 degrees 0 degrees Power rating 10W 200W 10W Impedance 50 ohms 50 ohms 50 ohms Termination Type N male Type N female Type N male Lightning protection Direct ground Direct ground Direct ground Overall length radome diameter 13 in. 2.375 in. OD 65 in. 1.310 in. OD 13 in. 2.375 in. OD Mounting area length n/a ~8 in.  n/a Weight (without clamps) 1 lbs.  6 lbs.  1 lb. Maximum wind speed 160 mph 125 mph 160 mph Wind load @ rated wind speed n/a 57 lbs.  n/a  For the latest antenna part numbers, see the CCU 100 Ordering Guide or contact your Itron representative. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication.
 Environmental Specifications   CCU 100 and Repeater 100 Installation Guide    51  Proprietary and Confidential   Environmental Specifications The following environmental specifications are associated with a CCU/Repeater.  Specification Value Operating temperature Components    GPS/WAN antenna system: -33° C to 60° C   CCU/Repeater: -33° C to 60° C Storage temperature  -40° C to 85° C Note  Batteries may be stored for up to two years at 25° C without periodic recharging. When batteries are stored at this temperature, an open circuit voltage audit should be conducted every six months.  If the storage temperature is significantly higher than 25° C, the frequency of the audits must be increased.  Humidity 0 to 90% non-condensing    Transmitter Detailed specifications for the CCU/Repeater transmitter are described in the following table.  Specification Value Maximum transmit power at antenna 27 dBm Frequency 903.0 MHz to 926.8 MHz (USA)   CCU/Repeater Power Operating Range   Specification Value Voltage 90 VAC to 265 VAC Frequency 47 Hz to 63 Hz  Average power 10 Watts (battery trickle charge) Peak power 50 Watts
Appendix A Detailed CCU/Repeater Specifications  52   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential   Battery Pack The battery pack is contained in its own compartment. The battery pack is a three-cell, sealed, lead acid battery pack (6V, 4.5 amp-hours) that is field replaceable and designed to last five years under normal circumstances. To ensure minimal impact upon battery life, a preventative maintenance schedule of two year replacement is required in an extreme environment, such as a desert installation. Normal preventative maintenance is every five years for non-hot environment installations.     Warning   Risk of explosion if battery is replaced by an incorrect type. Always replace with Itron part number BAT-0045-001. The batteries can power the system for a duration of 90 minutes in the case of a power outage.   If Then AC power fails  The CCU/Repeater battery pack maintains system functions for approximately 90 minutes. A message indicating the AC failure is sent to the Network Software.  AC power is restored A message is sent to the Network Software indicating that AC power has been restored.  The battery pack specifications are listed below.  Specification Value Type Sealed-lead acid, rechargeable Power 6V, 4.5 amp-hours Life Five years at 33° C. Battery life decreases by 50% for each 8° C rise in temperature above 25°C.  Charge time 10 hours at 25° C The battery in the CCU/Repeater uses three EnerSys Cyclon lead-acid cells connected in series to provide a nominal voltage of 6 volts. The battery is terminated with a four position Molex connector (Molex P/N #39-01-4041) with the following pinout: Pin # Wire Color Signal 1  Red +V BATT 2  Black Ground 3  White Thermistor 4  White Thermistor For information on battery disposal/recycling contact EnerSys at 1.800.363.7797 or recycling@enersys.com.
  CCU 100 and Repeater 100 Installation Guide    53  Proprietary and Confidential  Status Indicator The LED Status Indicator is primarily intended to support installation personnel for immediate feedback. The following sequences define the Fixed Network solution's operational characteristics:  1. Each status sequence is repeated at 20 second intervals. The following status indicators are enabled at power-up or upon a communication failure with endpoints or backhaul.   Initial power-on and CPU has initialized, but neither endpoint or backhaul communication has started: Morse "P" (● ▬ ▬ ●)  2. Super Raptor radio is seeing bubble-up endpoints but has not connected to the backhaul: Morse "N" (▬ ●)  3. Backhaul radio is communicating, but no communication from endpoints: Morse "B" ( ▬ ● ● ●)  4. Connected to backhaul radio & receiving endpoint packets: Morse "BN" ( ▬ ● ● ● ▬ ● )  After 15 minutes of successful communication with backhaul and endpoints following a power-up (or communication failure), the sequence changes to LED on for 10 mSec, at 60 second intervals. This will continue until the next power-up.  Sequence details: The dot time: 100 mSec The dash time is 300 mSec  Off Time between B and N: 700 mSec  Off time between dot and dash: 100 mSec APPENDIX B  Status and Diagnostics
Appendix B Status and Diagnostics  54   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential   Diagnostic Port The wireless diagnostic port is based on the IEEE 802.11 LAN/MAN wireless specification. The 802.11 Wi-Fi interface has been exclusively designed to support system diagnostic capabilities and is intended to be available for field personnel use. • The diagnostic radio is available only at power up of the system or by the reception of a wake-up message that is received by the 900 MHz radio. Once the wake-up message is validated by the 900 MHz radio the CCU 100 host powers on the diagnostic radio interface and configures it for communications. By default, the operation period of the diagnostic port is set to 30 minutes. Once this operational time has expired the radio interface is disabled and eventually powers down until the next system power up event or a wake-up command is sent to the 900 MHz radio.  • The diagnostic radio provides a dynamic Web-based hosted interface for environmental sensors and system health. The local diagnostic Web port for the CCU 100 provides:  • Network operations information  •    Contents of report list       •     Number of endpoints on the list        •    IDs of endpoints on the list  •    Contents of management list        •    Number of endpoints on the list        •    IDs of endpoints on the list  •    Contents of the ignore List        •    Number of endpoints on the list        •    IDs of endpoints on the list  •    Content of total endpoints received list        •    Number of endpoints on the list        •    ID’s of endpoints on the list  •    Endpoint read reliability statistics table   •    History of FNAS commands received      •    Source of time (GPS or NTP)  •    List of pending 2-way commands
 Performing an Antenna Sweep Test   CCU 100 and Repeater 100 Installation Guide    55  Proprietary and Confidential  • CCU/Repeater status •    Power source (AC or battery)  •    Battery state  •    Internal temperature  •    GPS status (number of satellites + GPS time and lat/lon position)  •    Firmware versions  •    Hardware versions  • Event logs  •    Power outage logs  •    WiFi access logs  •    High temp/Low temp alarms  • Configuration collection  •    TX power  •    Endpoint filtering settings  •    Configuration items settings  •    Firmware update interface  •    Force reboot   Performing an Antenna Sweep Test If the endpoint antenna is remotely mounted for your installation, an antenna sweep test must be performed to verify that the antenna functions within acceptable tolerances at your installation site.  This test should be performed under the following conditions:  • Beginning Frequency:  902 • Ending Frequency:  928 • VSWR Expected Results:  Must be 1.5 or less for the specified frequency band. • Return Loss:  Must be –18dB or better for the specified frequency band. Any deviations from this return loss warrant further investigation. • Test Point:  Feed line connected to the antenna at the top; test from the lightning (or surge) arrestor to the antenna port. • Results: Test results must be saved in. PDF format.  • Test Gear: Current and proper calibration; be sure that calibration is turned on during the test. A qualified operator of the test equipment must perform the test.   Note  If the system does not perform to the above test specifications, the reasons for system failure and possible remedies must be identified before leaving the installation site.
Appendix B Status and Diagnostics  56   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential
  CCU 100 and Repeater 100 Installation Guide    57  Proprietary and Confidential  A AC service requirements • 9 antenna placement • 9 antenna specifications • 50 antennas • 3, 5, 9, 10, 11, 18, 19, 50, 55 attaching the CCU/Repeater • 21 attaching the direct mount antenna • 19 attaching the remote antennas • 18 B battery • 44 battery pack • 52 battery storage • 44 brackets • 15, 21 C calendar life • 46 CCU configuration • 1 CCU power operating range • 51 CCU specifications • 49 charging • 44 coaxial cable • 13 components • 2 connecting cables • 29 connectors • 14 D davit arm mount • 27 diagnostic port • 54 dimensions • 49 E endpoint antenna • 5, 9, 10, 11, 18, 19, 50, 55 environmental specifications • 51 Ethernet connections • 9 external Ethernet connections • 9 G GPS antenna • 3, 8, 10, 11, 18, 50, 55 GPS coverage • 8 grounding • 1, 5, 10, 11, 13, 50 I installation profiles • 7 installing the battery • 30 installing the CCU/Repeater • 17 L lightning arrestor • 11 long-term storage • 44 M mains powered installation • 12 maintenance • 43 materials not provided by Itron • 13 module • 2 mounting hardware • 15, 21 O operating range • 51 P performing an antenna sweep test • 55 pipe mount • 22 planning • 7 pole mount • 24 power operating range • 51 preventative maintenance • 46 profiles • 7, 12, 39 propagation study • 8 providing power • 32 R remote antenna placement • 9 remote antennas • 3, 5, 9, 10, 11, 18, 50, 55 Repeater power operating range • 51 Repeater specifications • 49 replacing the battery • 47 S service life • 46 shipping requirements • 43 site selection • 8 siting • 8 Index
Index    58   CCU 100 and Repeater 100 Installation Guide  Proprietary and Confidential  solar installation diagram • 41 solar powered installation • 39 solar wiring diagram • 40 specifications • 49, 50, 51 state of charge • 45 status indicator • 53 storage • 44 T transmitter • 51 W wall mount • 26 WAN antenna • 3, 8, 10, 11, 18, 50, 55 WAN coverage • 8

Navigation menu