Itron IMU516 RF Module for Utility Gas Meter User Manual IMU200 Wiring Rev01

Silver Spring Networks RF Module for Utility Gas Meter IMU200 Wiring Rev01

Contents

User Manual (Wiring)

Download: Itron IMU516 RF Module for Utility Gas Meter User Manual IMU200 Wiring Rev01
Mirror Download [FCC.gov]Itron IMU516 RF Module for Utility Gas Meter User Manual IMU200 Wiring Rev01
Document ID1459821
Application IDeLhGiNf1qcxxxTsk7oWL4A==
Document DescriptionUser Manual (Wiring)
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize2.76kB (34456 bits)
Date Submitted2011-05-05 00:00:00
Date Available2011-05-12 00:00:00
Creation Date2011-02-25 15:20:30
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2011-02-25 15:20:30
Document TitleMicrosoft Word - IMU200_Wiring_Rev01.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: rbgrumm

IMU-200 Remote Mount
Pulser Wiring Information
Rev. 01, February 25, 2011
1 Overview
This document is intended to describe the wiring of the IMU-200 Remote Mount Module to
various partner devices. Internally these projects are referred to as ComGas 1 and ComGas 2.
The ComGas 1 consists of a Remote Mount IMU connected to a Riotronics pulser with a tamper
interface.
The ComGas 2 connects a Remote Mount IMU to a Mercury Corrector Unit, with support for
tamper and 2 channels of data, both uncorrected and corrected. This requires 4 channels of
input data to the IMU and tamper detection.
Doc:
Silver Spring Networks - Confidential and Proprietary
Page 1 of 4
2 Architecture
The Remote Mount IMU pulse input is compatible with a Form A (normally open) switch. The
voltage to the input is provided by an internal pull-up as shown in Figure 1. The voltage and
timing for a valid input pulse to the Remote Mount IMU is shown in Table 1 and Figure 2.
Figure 1 – Pulse Input Electrical Diagram
Table 1 – Pulse Electrical Parameters
Spec
Nom.
Min.
Max.
VBAT
2.1V
1.9V
2.14V
VIL
--
-0.5V
0.36V
VIH
--
1.5V
2.3V
tFall
--
--
10 ms
tLow
--
15 ms
100ms
tRise
--
--
140 ms
tPeriod
--
500 ms
--
Figure 2 – Pulse Diagram
Doc:
Silver Spring Networks - Confidential and Proprietary
Page 2 of 4
2.1 Connection Definitions
The Remote Mount IMU has been tested with two devices to support current customer needs.
These devices are the Riotronics –PS4 model and the Mercury Corrector. Signal connections to
each of the devices are shown in Table 2.
Table 2 – PCBA Connections
Pin
IMU-300
Riotronics –PS4
Mercury Corrector
Pulse IN Ch. 1
Pulse Out
Pulse Out Ch. A +
Ground
Ground
Ground
Pulse IN Ch. 2
N/C
Pulse Out Ch. B +
Ground
N/C
N/C
Pulse IN Ch. 3
N/C
Pulse Out Ch. A Corrected +
Ground
N/C
N/C
Pulse IN Ch. 4
N/C
Pulse Out Ch. B Corrected +
Ground
N/C
N/C
Tamper+
Tamper
Tamper +
10
Tamper-
N/C
N/C
2.1.1 Riotronics –PS4
The Riotronics –PS4 is a single channel form A switch with tamper detection. The wire definitions
for the Riotronics –PS4 is as follows:
Table 3 – PCBA Connections
Pin
Signal
Pulse Out
Red
Ground
Black
Tamper
Bare wire
w/ wire end sheath
Wire
2.1.2 Mercury Corrector
The Mercury Corrector uses differential channels for each of the signals, meaning that there is a
Pulse Out Ch. A + and a Pulse Out Ch. A -. All of the negative or return path signals should be
connected together at the Mercury Corrector unit and connected to the Ground wire on the cable
to the Remote Mount IMU.
Doc:
Silver Spring Networks - Confidential and Proprietary
Page 3 of 4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2011:02:25 15:20:30-08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2011:02:25 15:20:30-08:00
Format                          : application/pdf
Title                           : Microsoft Word - IMU200_Wiring_Rev01.doc
Creator                         : rbgrumm
Document ID                     : uuid:eac8a5bc-d8c3-45c7-a1e8-bcc2d73d185d
Instance ID                     : uuid:a0b263d5-4ede-4e06-aca0-e7104b7ea738
Page Count                      : 3
Author                          : rbgrumm
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OWS-IMU516

Navigation menu