Itron SNIC1 Smart Network Interface Card Module User Manual Manual

Itron, Inc. Smart Network Interface Card Module Manual

Manual

    5015 B.U. Bowman Drive  Buford, GA 30518 USA   Certification Exhibit     FCC ID:  SK9SNIC1 IC: 864G-SNIC1  FCC Rule Part: 15.247 ISED Canada Radio Standards Specification: RSS-247  Project Number:  72124916   Manufacturer: Itron, Inc. Model: SNIC1     Manual
  OpenWay® Riva™ Smart Network Interface Card (NIC)  User Guide
  Identification OpenWay® Riva™ Smart Network Interface Card (NIC)  User Guide - Draft 24 March 2017   TDC-XXXX-YYY OpenWay® Riva™ Smart Network Interface Card (NIC)    Copyright ©  2017 Itron, Inc. All rights reserved.  Confidentiality Notice The information contained herein is proprietary and confidential and is being provided subject to the condition that (i) it be held in confidence except to the extent required otherwise by law and (ii) it will be used only for the purposes described herein. Any third party that is given access to this information shall be similarly bound in writing.  Trademark Notice Itron is a registered trademark of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.  Suggestions For more information about Itron or Itron products, see www.itron.com. If you have questions or comments about the software or hardware product, contact Itron Technical Support Services.  Contact • Email:  support@itron.com • Internet:  support.itron.com • Telephone Itron Technical Support North America:  1-877-487-6602 For technical support contact information by region, go to www.itron.com and select your country and language.   FCC Part 15, Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.   Changes or modifications to this device not expressly approved by Itron, Inc. could void the user’s authority to operate the equipment.  Regulatory Compliance
  Innovation, Science and Economic Development Canada (ISED) This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à la norme Canadienne sur le matériel brouilleur. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif ne peut pas causer d'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris les interférences pouvant entraîner un fonctionnement indésirable. Under Innovation, Science and Economic Development Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Innovation, Science and Economic Development Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. RF Exposure (FCC/ISED) The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Under ISED regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by ISED . To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Professional Installation These antennas are intended for professional installation by the integrator. The OEM integrator is still responsible for the FCC compliance requirement of the end product, which integrates this antenna. Modification and Repairs To ensure FCC compliance and system performance, this device, antenna and/or coaxial assembly shall not be changed or modified without the express written approval of Itron.  Any unauthorized modification will void the user’s authority to operate the equipment. This device contains no user serviceable parts. Attempts to repair this device by unauthorized personnel may subject the person to shock hazard if removal of protected covers is attempted. Unauthorized repair will void the warranty and/or maintenance contract with your company.
    Labeling The following requirements apply to any products that use this module. The end product or host label includes the following text:    • Contains: • FCC ID: SK9SNIC1 • IC: 864G-SNIC1, Model: SNIC1  The user’s manual for any product that contains this module must contain the following text.  If the device is large enough, then this must also be placed on the label.   "This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation."    The product you have purchased may contain a battery (or batteries), circuit boards, and switches. The batteries are recyclable. At the end of the product’s useful life, under various state and local laws, it may be illegal to dispose of certain components into the municipal waste system. Check with your local solid waste officials for details about recycling options or proper disposal.  Recycling Information
 IT Department User Guide  v     Regulatory Compliance................................................................................................. ii FCC Part 15, Class B ................................................................................................................ ii Changes or modifications to this device not expressly approved by Itron, Inc. could void the user’s authority to operate the equipment. ............................................................................... ii Innovation, Science and Economic Development Canada (ISED) .......................................... iii RF Exposure (FCC/ISED) ........................................................................................................ iii Professional Installation ................................................................................................. iii Modification and Repairs ............................................................................................... iii Labeling ......................................................................................................................... iv Recycling Information .................................................................................................. iv Overview......................................................................................................................... 1 Module Description ....................................................................................................... 3 Module boards ..................................................................................................................................... 3 Module enclosure (option) ................................................................................................................... 4 Module enclosure nameplate .............................................................................................................. 5 Module enclosure installed in optional host ........................................................................................ 5 Enclosed module in optional host showing label ................................................................................ 6 Enclosed module in optional host ....................................................................................................... 6 Module Specifications ....................................................... Error! Bookmark not defined. Power ................................................................................................. Error! Bookmark not defined. Environmental .................................................................................... Error! Bookmark not defined. Interfaces ............................................................................................ Error! Bookmark not defined.   Contents
Contents  IT Department User Guide  vi      Labeling   The following requirements will be applied to any products that use this module:    The end product or host label will include the following text:    • Contains: • FCC ID: SK9SNIC1 • IC: 864G-SNIC1, Model: SNIC1  The user’s manual for any product that contains this module will contain the following text.  If the device is large enough, then this will also be placed on the label.    “This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.”  Regulatory Compliance   The user’s manual for any product that contains this module will contain the following text:      FCC Part 15, Class B This equipment has been tested and found to comply with the limits for a Class B digital    device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:     • Reorient or relocate the receiving antenna.     • Increase the separation between the equipment and receiver.     • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.     • Consult the dealer or an experienced radio/TV technician for help.
Contents   IT Department User Guide  vii     Changes or modifications to this device not expressly approved by Itron, Inc. could void the user’s authority to operate the equipment.    Innovation, Science and Economic Development Canada (ISED)  This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.   Cet appareillage numérique de la classe B répond à la norme Canadienne sur le matériel brouilleur. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif ne peut pas causer d'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris les interférences pouvant entraîner un fonctionnement indésirable.  Under Innovation, Science and Economic Development Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Innovation, Science and Economic Development Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.  RF Exposure (FCC/ISED) “This equipment complies with radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.”  “Cet équipement est conforme aux limites d'exposition aux radiations dans un environnement non contrôlé. Cet équipement  do it être installé et utilisé à distance minimum de 20 cm entre le radiateur et votre corps. Cet émetteur ne doit pas être  co-localisées ou opérant en conjonction avec tout autre antenne ou transmetteur.”  Miscellaneous    The user’s manual for any product that contains this module will contain the following text:    Professional Installation  This module is intended for professional installation by the integrator. The OEM integrator is still responsible for the FCC compliance requirement of the end product, which integrates this module.  Modification and Repairs   To ensure FCC compliance and system performance, this device, antenna and/or coaxial assembly shall not be changed or modified without the express written approval of Itron.  Any unauthorized modification will void the user’s authority to operate the equipment.  WARNING! This device contains no user serviceable parts. Attempts to repair this device by unauthorized personnel may subject the person to shock hazard if removal of protective covers is attempted.  Unauthorized repair will void the warranty and/or maintenance contract with your company.  General Description The Itron SNIC1 is a communications module which includes a 902.4 MHz to 927.6 MHz transmitter as well as Wi-Fi.
Contents  IT Department User Guide  viii      The module operates on DC voltage which is supplied by a optional power board or host device.       Recycling Information  The product you have purchased contains circuit boards. At the end of the modules useful life, under various state and local laws, it may be illegal to dispose of certain components into the municipal waste system. Check with your local solid waste officials for details about recycling options or proper disposal.  About this Manual This technical reference guide describes the installation of the SNIC1 for the Itron Range Extender.
 IT Department User Guide  1     This document provides information on the design, construction, and operation of the OpenWay Riva Smart Network Interface Card (NIC) module.  The module consists of two major components: the communications board and the antenna. The sample module housing is constructed using polycarbonate material that provides protection for the internal components. Power may be supplied from optional power board or supplied from a host supply. This module contains the cutting edge communication technology featuring IPv6 RF and Power Line Carrier Communications. OpenWay features an innovative multimedia IPv6 network that uses both RF and PLC links within a mesh to route messages and data between standards-based smart meters (DLMS/COSEM) and the head-end system. Itron’s communication module also enables secure two-way communication with home energy management devices using G3 PLC, Wi-Fi and protocol stacks SEP 2.0 and ECHONET Lite. The communication module enables utilities to deploy the network without specific network planning and segregation for RF and PLC environments. Intelligence in the module chooses the communication link quality and modulation scheme that support the best possible data rate. Data rates of up to 500kbps are achievable by this multimedia mesh. This is done automatically in real-time by the modules without any need for pre-programming or path hard-coding. The communication modules create their own multi-hop environment using the best available physical path for communication where the routing is managed by standardized IETF routing protocols that are independent of the physical link. Itron’s technology offers a unique way to deploy the same communication module anywhere, regardless of traditional network design considerations, such as geography, density, or structural environment.  CH A P T E R  1  Overview
Overview  IT Department User Guide  2
 IT Department User Guide  3       Module boards The Smart NIC Module contains 2 boards: the network interface card and the antenna board (shown with optional power board). The power board and the NIC board are separated by a plastic standoff as shown in the illustration.  CH A P T E R  2  Module Description
Module Description  IT Department User Guide  4      Illustration Callout  # Field 1  NIC Board 2  Power Board 3  Plastic Standoff  4  Antenna Board   Module enclosure (option) The Smart NIC modules can be enclosed in the sealed polycarbonate enclosure shown in the illustration for installation various optional hosts.
Module Description  IT Department User Guide  5     Module enclosure nameplate  Module enclosure installed in optional host
Module Description  IT Department User Guide  6      Enclosed module in optional host showing label  Enclosed module in optional host
Module Specifications  IT Department User Guide  7      Power  Requirements  Description Peak Power Consumption:  Total Instantaneous Peak @ 24vdc:  13W  Long Term Thermal Average @ 24vdc:   3.5W  Idle Average (Receive Only) @ 24vdc only:  2W   Environmental Environmental  Description Operating Temperature  -25°C to +70°C  Normal operating temperature  -40°C to +85°C  Limited operating temperature* Note*: Limited operating temperature is defined as being type tested at temperature extremes for operation up to 16 hours. Humidity  5% to 95%  Noncondensing   Interfaces Signals  Description Power Line Carrier (PLC)  Single Phase Connection  2-pin interface  Protection & Coupling included on Host device/meter  Protocol  IEEE 1901.2  Adaptive Tone Mapping, Mesh Operational Bands(one of three bands, based on target markets)  FCC above CENELEC  ~ 155kHz to 488kHz  ARIB2  ~ 155kHz to 403kHz Modulations  Data Rates  D8PSK  DQPSK  200 kbps  165 kbps   CH A P T E R  3  Module Specifications
Module Specifications  IT Department User Guide  8      DBPSK  ROBO  Super-ROBO  100 kbps  34 kbps  23 kbps    Radio Frequency (RF)  Embedded Antenna  For devices/meters with plastic enclosure  Optional RF Connector  For devices/meters with metal enclosure or special needs Protocol  IEEE 802.15.4g/e  Frequency Hopping, Mesh Operational Bands (one of three bands, based on target markets)  900 MHz ISM  Channels adjusted for market specific needs  870 MHz  Channels adjusted for market specific needs  (For international markets where permitted) Output Power  1 Watt  Maximum EIRP. Power adjusted to meet local requirements Modulations  Data Rates  802.15.4g OFDM option 3   200 kbps,600 kbps and 1.2Mbps      802.15.4g FSK   150 kbps (or 50 kbps mandatory mode)  Long Range mode   6.25 kbps, 12.5 kbps Wireless  Wi-Fi  802.11 b/g/n
 IT Department User Guide  9      CH A P T E R  4

Navigation menu