JBL_Control_24C-CT_Manual_csman JBL Control 24CT (B-Stock) | Background/ Foreground Ceiling Loudspeaker

DOC_1048 JBL - Manuals+

19csman JBL - Manuals+

csman JBL - Manuals+

JBL_Control_Contractor_Ceiling_Owners_Manual JBL Control 26CT (B-Stock) | 6.5 Ceiling Loudspeaker Transducer Assembly

User Manual: JBL JBL Control 26CT (B-Stock) | 6.5 Ceiling Loudspeaker Transducer Assembly

Open the PDF directly: View PDF PDF.
Page Count: 19

DownloadJBL - CEILING SPEAKER OWNERS MANUAL TEXT Control Contractor
Open PDF In BrowserView PDF
Control Contractor
Ceiling Loudspeakers
Owner’s Manual

Table of Contents
Product Description......................................................................................... 2
Product Feature Identification......................................................................... 3
Installation Preparations.................................................................................. 4
Step-By-Step Installation and Wiring............................................................. 6
Painting the Speaker...................................................................................... 15
Safety Agency Compliance........................................................................... 16
Maintenance .................................................................................................. 16
Replacement Parts......................................................................................... 17
Contacting JBL.............................................................................................. 17

1

Thank you for purchasing JBL Control Contractor ceiling loudspeakers.
Read through this manual to familiarize yourself with the features, applications and
precautions before you use these products.

Product Descriptions
The JBL Control Contractor ceiling loudspeakers utilize innovative design and
materials to provide premium level performance from compact in-ceiling speakers.
CONTROL 24C & 24CT – Most compact of the JBL ceiling speakers, the Control
24C contains a coaxially mounted 4” woofer and ¾” titanium-coated tweeter,
providing high-fidelity full-range sound over an extremely wide coverage area. The
optional Control 24CT includes a multi-tap transformer for 70V or 100V systems.
CONTROL 26C & 26CT – The Control 26C is a powerhouse ceiling speaker
containing a coaxially mounted 6.5” woofer and ¾” titanium-coated tweeter, able to
deliver maximum sound level over a wide coverage area. The optional Control 26CT
includes a multitap transformer for a 70V or 100V line distribution system.
CONTROL 19CS & 19CST Subwoofer – The unique Nested Chamber design and
Linear Dynamics port allows powerful low-frequency reinforcement from a
compact in-ceiling enclosure. The Control 19CS is an ideal addition to any system,
resulting in full-fidelity high level sound. The optional Control 19CST includes a
special subwoofer-band transformer for use on 70V or 100V line distribution systems.

2

Product Feature Identification
(Control 24C Shown)

Steel Backcan

Loudspeaker
Di
Tap Selector (on T-versions)

Attachment Screws

Strain Relief Fitting
Removable Locking Input Connector

Seismic Tab
(secondary support point)

Terminal Cover Plate Assembly

Rotating Mounting Tabs

Perforated Press-In Grille

JBL Logo

3

Installation Preparations
The entire installation can be accomplished, if necessary, without requiring access
above the ceiling. Bracketry for use with either suspended ceilings or sheetrock
ceilings is included. The speaker is held securely in place via mounting ears which
lock into place. Inputs are attached to a removable locking connector (included)
which can be prewired before installing the speaker for ultra-fast snap-on installation.

OPTIONAL PRE-INSTALLATION BRACKETS
IN MOST CASES, NO BRACKETS OTHER THAN THE ONES INCLUDED WITH
YOUR SPEAKER ARE REQUIRED. Everything needed for most installations of
these loudspeakers is provided with your Control Contractor ceiling speaker.
However, a particular procedure that is sometimes used for installation into sheet rock
(typically gypsum board) can be facilitated by the use of JBL’s optional preinstallation
brackets before the sheetrock is installed. The preinstallation bracket provides a
bracket to which wiring can be tied behind the sheetrock and it can function as a
cutout template when many cutouts are to be made in a production-line style
installation. Two types of pre-installation brackets are available from JBL
Professional as optional accessories:
1) The optional NEW-CONSTRUCTION BRACKET is made of flat sheetmetal,
with wings to attach to the building structure. Holes are drilled for nails or screws at
16 inches (406 mm) and 24 inches (610 mm) on-center. Additional holes can be
drilled by the installer at other spacings up to a maximum of 24-3/4 inches (630 mm)
apart. Sheet rock installs over the bracket, and the bracket provides a template for
blind cutout of the hole in the sheet rock. The sheet rock is typically cut with a routertype cutting tool, using the bracket ring as a cutout guide.

Figure 1:
Optional New -Construction Bracket

4

2) The optional PLASTER-RING BRACKET (or “mud ring”) contains a circular
offset, forming a edge guide for sheet rock plastering. The bracket has wings that
attach to the building structure. Sheet rock is typically either precut or cut with a
rotary cutting tool using the outside of the plaster ring circle as a guide. The sheet
rock hole is then plastered (or “mudded”) up to the ring to create a seamless cutout.

Figure 2:
Optional Plaster Ring Bracket

Model

New
Construction
Bracket

Plaster-Ring
Bracket

Control 24C & 24CT

MTC-24NC

MTC-24MR

Control 26C & 26CT

MTC-26NC

MTC-26MR

Control 19CS & 19CST

MTC-19NC

MTC-19MR

USING INCLUDED C-BRACKET WITH SHEETROCK

For most installations, the INCLUDED C-shaped backing plate to provides adequate
reinforcement to the ceiling material, spreading out the clamping force from the tab
clamps.

CUTOUT SIZES

Packaged with the speakers are cardboard cutout templates for scribing the cutout hole
onto your ceiling surface.

Model

Cutout Size
(diameter)

Control 24C & 24CT

168 mm (6.6 in)

Control 26C & 26CT

220 mm (8.75 in)

Control 19CS & 19CST

305 mm (12.0 in)

5

STEP-BY-STEP
INSTALLATION AND WIRING
The installation system has been designed so that the entire installation can be
accomplished from beneath the ceiling, for instances when access above the tile is not
possible or practical. However, in some cases it may be easier with removable ceiling
tiles to access from both the top and bottom of the ceiling tile during various phases of
the installation.
Step 1 – Cut the Hole. Cutout the hole size either by tracing the cardboard cutout
template or with a circular cutter set to the cutout sizes listed above. Pull the wiring
through the cutout hole.

Figure 3:
Hole Cutout

Step 2 – Insert Backing Hardware Through the Hole. Packaged with the speakers
are two types of backing hardware – a C-shaped backing-plate bracket and two tile
rails.
Suspended Ceilings – Insert the C-plate through the hole cut in the ceiling tile.
Place the C-plate around the hole with the tabs located as shown on Figure 4.
Insert the tile rails through the cut hole in the ceiling tile. Snap the two rails into the
two tabs in the C-plate and align the rails so that the ends extend OVER the Tchannel grid on the side of the tile. Secure the rails onto the C-bracket tabs by
inserting a screw though each tab into the rail. This can all be accomplished from
below the ceiling tile, if necessary.
 ! " #
ALL included support brackets – C-plate and tile rails -- MUST be used
when installing into suspended ceiling tiles.
6

Figure 4:
C-Bracket and Tile Rail
Positioning on Ceiling Tile

Tile Rails: The tile rails are designed to fit either standard 24-inch wide tiles or 600-mm wide tiles.
The tile rail pieces do NOT physically attach to the T-grid struts. Instead, the inverted-V shape at the
ends of the rails sit OVER the T-grid strut. During normal operation, the rails are supported by the edge
of the tile. In the unlikely even that the tile comes out or falls apart, the ends of the support rails are
designed to catch onto the T-grid, providing secure support to hold the loudspeaker assembly in place.
Vibration Reduction: These loudspeakers can generate substantial vibration, which can cause buzzing
of the ceiling materials or structure. Depending on the character of the ceiling tile and structure, the
installer might need to place neoprene or other dampening material under the tile rails or the edges of
the tiles to eliminate rattles.
Cutout Placement: The tile rails are pre-punched with attachment holes along their length. Placement
is not limited to the center of the tile as is the case with many other tile rail support systems.

Non-Suspended Ceiling Types – The C-bracket can be optionally used by itself to
shore up the ceiling material and to spread out the clamping force from the tab
clamps. Insert the C-plate through the cut hole in the ceiling and place it on the
back side of the hole before inserting the speaker.

Step 3 – Connect the Wiring to the Removable Locking Connector – Connect the
wiring to the removable locking connector that is INCLUDED with the speaker by
stripping the insulation back about 5 mm (about 3/16 inch), inserting the bare end of
wire into the connector and screwing down the hold-down screw until tight using a
small flatblade screwdriver. Tighten any unused screws to avoid vibration.

Figure 5:
Connecting Wires to
Removeable Locking Connector

7

Guide to the Pins for Connection -- The removable locking input connector
contains 4 terminals, as marked on the connector. The pin functions are listed on
the label located on the terminal cover plate.
CONNECTION

1 2 3 4

Figure 6: Connector Pins

+

–

Loop
Thru

Loop
Thru

+

–

IN

IN

Pins 2 & 3 are the “+” and “-” inputs to the loudspeaker. Pins 2 & 3 are looped to
pins 1 & 4, respectively (Pin 1 connects to Pin 2 and Pin 3 connects to Pin 4) inside
the speaker. Pins 1 & 4 are intended as loop-through connections to subsequent
loudspeakers. There are two possible hookup schemes for connecting subsequent
speakers, determined by the desired result from the circuit whenever this speaker’s
connector gets disconnected during troubleshooting:
Paralleling Input Terminals -- Connect the wire pair of the subsequent
speaker to pins 2 & 3 (in parallel with the input wire pair). Whenever the
connector is pulled out of the speaker for troubleshooting, subsequent speakers
will stay connected. This can be useful during troubleshooting to be able to
disconnect a single loudspeaker at a time. In this hookup scheme, no wires get
connected to pins 1 & 4.
Figure 7:
Paralleling Input Terminals

From Amplifier or
Previous Speaker

1 2 3 4

+

–

–

+

To Subsequent
Speakers

Figure 8:
Parallel System
Hookup Diagram
+
–
1

+

Power Amplifier

8

–

2

3 4

Speaker 1

1

2

3 4

Speaker 2

1

2

3 4

Speaker 3

To
Subsequent
Speakers

Using Loop-Through Terminals (Pins 1 & 4) -- By connecting the wire pair of
the subsequent speaker to pins 1 & 4, then all subsequent speakers will be
disconnected when this speaker’s connector is disconnected during for
troubleshooting,. This can be useful as a way to isolate problems to a section of
the distributed line while leaving the wires attached to the connector.
Figure 9:
Using LoopThrough Terminals

1 2 3 4

From Amplifier or +
Previous Speaker –

– To Subsequent
+

Speakers

Figure 10:
Loop-Through
System Hookup
Diagram

+
–
1

+
Power Amplifier

–

2

3

Speaker 1

4

1

2

3

Speaker 2

4

1

2

3

To
Subsequent
Speakers

4

Speaker 3

Choose whichever hookup pattern accommodates your installation best.

Step 4 – Plug connector into connector socket in the speaker’s terminal cup.

Figure 11:
Plugging Connector Into
Connector Socket

9

Step 5 – Tighten the Strain Relief Fitting & Close the Terminal Cover
First, remove the horizontal screw indicated in the drawing below.

Figure 12:
Opening the
Strain-Relief Fitting

Next, loosen the screws holding the fitting’s sliding pieces onto the input-terminal
cover by about a half turn. Run the wires through the opening in the fitting.

Figure 13:
Running Wires
Through Opening
In Strain Relief
Fitting

10

The strain relief can be tightened in two ways, choose whichever is best for your
application:
a) Tightening onto plenum cable or bare wire -- Slide the wiring through the
strain relief fitting on the terminal cover plate. In the case of bare wire and
plenum cable it is often possible to provide acceptable strain relief force by
simply tightening the screws holding the sliding strain relief onto the terminal
cover plate. To achieve a tight fit, use a clamping mechanism (such as slipjoint
pliers) to hold the strain relief pieces together while tightening the hold-down
screws.
It is optional to reinsert the horizontal screw that was previously removed and to
tighten the two horizontal screws, clamping the wire securely between them.
Figure 14:
Tightening Fitting
Onto Plenum Cable (shown)
Or Bare Wire

11

b) Tightening onto flexible or hard conduit – The supplied fitting
accommodates up to 3/8 inch (9.5mm) flexible conduit. Slide the wiring
through the strain relief fitting on the terminal cover plate. Insert the conduit
into the strain relief fitting. Reinsert the horizontal screw that was previously
removed. Use the two horizontal screws that clamp the fitting together,
clamping the conduit securely between them.

Figure 15:
Tightening Fitting
Onto Conduit

Using an Alternate Fitting – The existing strain relief fitting accommodates many
common fitting requirements. Sometimes, alternate fittings are required, such as
for larger diameter conduit or to meet specific code requirements.
In these cases, the existing fitting can be easily replaced with a number of available
off-the-shelf fittings. Simply remove the existing fitting by unscrewing the two
hold-down screws, exposing a 7/8 inch (22mm) knockout hole. Install the alternate
fitting.





Always use the proper fitting in accordance with your area’s
building codes and regulations.
Close the Terminal Cover – Close the hinged terminal cover and secure it in place
with the hold-down screw.

12

Step 6 – Insert the Speaker Into the Ceiling and Tighten.
Insert the speaker into the ceiling as far as it goes, until the front baffle rim touches the
ceiling.

Figure 16:
Inserting Speaker
Into Ceiling

Turn the attachment screws to tighten the mounting tabs, by using the following
directions: IMPORTANT -- For each attachment screw, FIRST turn ½ turn
COUNTER-CLOCKWISE to release the mounting tab from its guide.
Then tighten the mounting tabs by turning the screw CLOCKWISE until tight. The
first ¼ clockwise turn rotates the attachment tabs outward and the remaining turns
tighten the tabs down onto the back of the ceiling surface. DO NOT
OVERTIGHTEN.
Figure 17:
Tightening Mounting Tabs

13

 



       

Model

Number of Attachment Screws

Control 24C & 24CT

3 screws

Control 26C & 26CT

4 screws

Control 19CS & 19CST

5 screws

Step 6 – Connect a Secondary Support Line to Seismic Tab – A tab is provided on
the back of each speaker for connection to a independent secondary support point.
Some construction codes require using this secondary support point, which requires
connecting a support line to a separate secure support point. Consult construction
codes in your region.

 ! 
Control Contractor ceiling speakers can generate substantial vibration . It is
HIGHLY RECOMMENDED to use the seismic tab as a secondary support
point in case the ceiling tile or structure breaks.

7.5
3.7

10

7.5
15

V 30
70 15

Step 7 for “T” Versions Only: Adjust Tap Selector – On T-version models
(Control 24CT, 26CT and 19CST) the tap selector switch is located on the front baffle.
Adjust the tap setting before inserting the grille. In some installations it is advisable to
leave the grilles OFF until final adjustment of the taps for the system.

V

30

0

14

Figure 18:
Tap Selector
(Shown: Control 24CT)

Step 8 – Insert the Grille – Consider which direction the logo is facing and press the
grille into place until the front of the grille is flush with the rim. Make sure grille is
securely seated to prevent it from vibrating loose and falling.
Removing the Grille -- The grille presents a tight fit in order to make sure that it
won’t fall out, even with high vibrations that can be produced by these speakers.
If you need to remove the grille, it is easiest to do so by inserting 2 pointed objects
(such as push pins) into 2 nearby holes in the grille, presenting slow even pressure
to pull down on the grille until that section of the grille comes out approximately 6
mm (1/4 inch) . Work your way around the grille, loosening a section at a time
until the grille comes out.

Painting the Speaker
The speaker’s textured white finish complements most decor and does not need further
finishing. Where the interior design requires it, these speakers are easy to paint.
The rim can be painted before installation or in cases where the rim needs to be finished
along with the ceiling, the speaker rim can be painted after attaching into the ceiling.
Type of Paint – The speaker’s polystyrene rim accepts almost any type of latex or oil
based paint. Two coats are recommended.
Painting Process – For best results, it is recommended to use the following
proceedure:
• Clean the rim and grille with a light solvent such as mineral spirits by rubbing the
item with a lightly dampened cloth. Do not, however, use abrasives such as
sandpaper or steel wool. Nor should you use gasoline, kerosene, acetone, MEK,
paint thinner, harsh detergents or other chemicals. Use of these cleaners may result
in permanent damage to the enclosure.
• After cleaning, apply two or more two thin coats of either latex or oil-based paints.
Latex paint will adhere better if an oil-based primer is used first. Application can
be made by rolling, brushing or spraying.
Painting the Speaker Along With the Ceiling – Insert the clear plastic paint shield
into the front of the speaker to mask the drivers and internal baffle, paint the speaker,
then remove the shield.
Painting the Grille – Painting the grille requires removal of the logo and the internal
grille cloth, they spray painting. If the grille is rolled or brush painted, the mesh may
become clogged with paint and poor sound quality may result. Replace the internal
grille cloth and JBL logo.
15

Safety Agency Compliance





  

 

Complies with the requirements of UL-2043 Fire Tests for Heat and Visible Smoke
Release for Discrete Products and their Accessories Installed in Air Handling Spaces,
NFPA-70 National Electric Code 1996, Article 300-22(C), and NFPA-90A Installation
of Air Conditioning and Ventilation Systems, Section 2-3.10.1 (a), Exception 3. Listed
UL1480-5 Speakers for Fire Protective Signaling Systems. For installation instructions
refer to JBL manual #CLNG SPKR MANUAL.
SUITABLE FOR USE IN AIR HANDLING SPACES.

These products are in compliance with the EMC Directive 89/336/EEC and Article 10 (1)
of the directive. In compliance with Technical Regulations EN50081-1 and EN50082-1.
For a copy of the model-specific CE Declaration of Conformity, contact JBL at the
address listed at the end of this manual.

Maintenance
No maintenance is required when installed in accordance with installation and wiring
guidelines described in this manual.

16

Replacement Parts
There are no user serviceable parts inside these speakers. The following replacement
parts are for reference only. Refer servicing to an authorized JBL Service Center. For
the name of an authorized Service Center in your area, contact JBL Professional at the
address listed below.
Control
24C
Driver (Speaker)
Transformer
Crossover
Network

Control
24CT

124-13000-00

Control
26CT

Control
19CS

124-16000-00

Control
19CST

124-58000-00

None

56200035-00

None

56200036-00

none

56200037-00

12920046-00

12920045-00

12920047-00

12920048-00

12910037-00

12910038-00

453-80000-00

Fuse (internal)
Protection Lamp

Control
26C

SK2

SK3

Input Connector

424-00092-00

Mounting Tab

885-00050-00

Warranty & Contacting JBL
These products are designed and backed by JBL Professional, the world leader in sound
reinforcement. For complete JBL warranty information, to order replacement parts or to
ask for clarifications to this manual, contact JBL Professional:
WITHIN THE UNITED STATES: Contact the Applications Dept, JBL Professional,
PO Box 2200, 8400 Balboa Blvd, Northridge CA 91329 USA. In the USA you
may call Monday through Fiday 8:00 am to 5:00 pm Pacific Coast Time (818) 8948850.
IN OTHER AREAS THROUGHOUT THE WORLD: Contact the JBL Professional
Distributor in your country.
A list of JBL Professional Distributors and U.S. Service Centers can be attained from
the JBL Professional WWW.JBLPRO.COM website.

17

JBL Professional
8500 Balboa Blvd, P.O. Box 2200
Northridge, CA 91329 U.S.A.

18

A Harman International Company

CEILING SPKR MANUAL
Rev D



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
About                           : uuid:573cc155-d81d-49b1-8456-09fce2548bd0
Producer                        : Acrobat Distiller 3.01 for Windows
Modify Date                     : 2006:12:12 12:09:10-08:00
Create Date                     : 1998:09:22 14:16:15Z
Creator Tool                    : ADOBEPS4.DRV Version 4.10
Metadata Date                   : 2006:12:12 12:09:10-08:00
Document ID                     : uuid:dd7597d0-a02f-446d-ac1b-baf0ee2c5b49
Instance ID                     : uuid:6eadee26-6f2c-47ea-8755-40d236b36bba
Format                          : application/pdf
Title                           : Microsoft Word - CEILING SPEAKER OWNERS MANUAL TEXT.rtf
Creator                         : mpaganin
Has XFA                         : No
Page Count                      : 19
Author                          : mpaganin
EXIF Metadata provided by EXIF.tools

Navigation menu