JCM Technologies FREE30R Reader User Manual 1247030 FREE 15 30 R 1 3 GB

JCM Technologies, S.A. Reader 1247030 FREE 15 30 R 1 3 GB

User Manual

COD. 1247030-GB / 1.3
FREE 15 R / FREE 30 R
1
Hands free activator.
TECHNICAL CHARACTERISTICS
FREE 15 R
FREE 30 R
Operating frequency 125kHz
Electricity 12/24V(ac)/(dc) +/- 10%
Consumption 50mA
Radiated power <25mW
Wiring 4 wires
Op. temperature -20ºC - +55ºC
Airtightness IP66
Size 87 x 78 x 15,5 mm 205 x 183 x 14 mm
Enabling area (hands-free mode) 1.5m 3m
INSTALLATION (figure A)
The activator is formed by two parts: a compact box (1) with a plastic front part and the wiring outlet at the back and an
adhesive trim (2). It is designed to be fitted directly to or built into the wall. It is secured by two screws (3), separated by
60mm (ideal separation if it is built-into a standard plug or socket box). The adhesive is fitted over Position 2 in the Figure,
ensuring that the led (5) is visible through the adhesive window. Before fitting the adhesive, screw in and configure the
activator.
N.B.: The activator should not be installed on metal surfaces, as this may reduce the enabling area.
COD. 1247030-GB / 1.3
FREE 15 R / FREE 30 R
2
CONNECTION
Connection is made through the wiring from the rear, which is connected directly to the auxiliary power supply.
Signal Cable colour
+ (12V) Red
- (GND) Black
Sync IN Green
Sync OUT White
Wiring diagram for the installation of an activator: Where one activator only is to be used, the IN and OUT synch. signals
must be short circuited.
Wiring diagram for the installation of more than one activator in series (maximum 4) and avoiding interference between
them. To do so, the OUT synch. signal must be connected to the IN synch. signal of the following activator.
COD. 1247030-GB / 1.3
FREE 15 R / FREE 30 R
3
CONFIGURATION OF CHANNELS AND GROUPS
Use the button (4) to configure the activator’s operating mode.
Channel configuration: Keep the configuration button pressed down until the number of long red signals is equal to the
channel to be configured. For example, if you want to configure channel 2, release the button after the second long red
signal.
Group configuration: Press the configuration button and keep it pressed down. The led will issue the red channel
configuration signals followed by a series of flashing green signals to indicate that the open group will start the group
selection sequence (long green signals indicating groups 1 to 7). Release the button at the required group. For example, if
you want to configure group 5, release the button after the fifth long green signal.
The procedure can be carried out as many times as required.
Channel: This allows for the channel to be sent to the receiver to be selected.
Group: This allows for the installation of more independently enabled doors (to a total of 22).
COD. 1247030-GB / 1.3
FREE 15 R / FREE 30 R
4
OPERATING
When the equipment is switched on, the LED will make as many red flashes as the channel you have configured and
so many green flashes as the group has set. Then the LED will be green fixed.
By bringing the tag/transmitter close to the hands-free activator or pressing the button, the activator will send a signal to
the receiver in which it is programmed.
USE OF THE EQUIPMENT
This equipment is designed for be used in the access control for automatic doors. It is not guaranteed for other uses.
The manufacturer reserves the right to modify equipment specifications without prior notice.
WARNING
Some structural elements of a building can affect the propagation of the signal that activates the tag. This can lead
to accidental activation of the tag when the unit is at a distance greater than 3m from the activator. If this
happens move the tag or the activator of his current location.
JCM TECHNOLOGIES, S.A. declares that the product FREE 15 R is compliant with the requirements of the 1999/5/EEC
Radio Equipment and Telecommunication Terminal Equipment Directive, provided it is used as established.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or
modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the
equipment.
CE DECLARATION OF CONFORMITY
See website: www.jcm-tech.com