JL MARINE SYSTEMS EA071 Boat mounted remote control User Manual 16 2088 Manual Coverx

JL MARINE SYSTEMS, INC. Boat mounted remote control 16 2088 Manual Coverx

Manual

Download: JL MARINE SYSTEMS EA071 Boat mounted remote control User Manual 16 2088   Manual Coverx
Mirror Download [FCC.gov]JL MARINE SYSTEMS EA071 Boat mounted remote control User Manual 16 2088   Manual Coverx
Document ID3803646
Application IDbB820drh1/PPviyqJr0RVA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize142.14kB (1776789 bits)
Date Submitted2018-04-02 00:00:00
Date Available2018-04-02 00:00:00
Creation Date2018-04-02 19:21:55
Producing SoftwareGPL Ghostscript 9.21
Document Lastmod2018-04-02 19:21:55
Document TitleMicrosoft Word - 16-2088 - Manual Cover.docx
Document CreatorMicrosoft Word - 16-2088 - Manual Cover.docx
Document Author: geris-je

Certification Exhibit
FCC ID: A7FEA071
IC: 11454A-EA071
FCC Rule Part: 15.247
ISED Canada’s Radio Standards Specification: RSS-247
TÜV SÜD Project Number: 16-2088
Manufacturer: JL Marine Systems, Inc.
Model: EA071
Manual
3998 NW 8th Ave (FAU Blvd) Suite 310, Boca Raton, FL 33431 USA Voice: 561-961-5585
General Statement (for all devices)
Warning: Changes or modifications to this device not expressly approved by JL Marine Systems, Inc. could
void the user’s authority to operate the equipment.
FCC Specific Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generate, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television receptio, which
can be dteremined by turning the equipment off and on, he user is encouraged to try to correct the interferecne
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
FCC Part 15.19 Warning Statement – (Required for all Part 15 devices) THIS DEVICE COMPLIES WITH
PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1)
THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
FCC/ISED RF Exposure
ENGLISH: This equipment complies with radiation exposure limits set forth for an uncontrolled environment.
This equipment is in direct contact with the body of the user under normal operating conditions. The transmitter
must not be co-located or operating in conjuction with any other antenna or transmitter.
FRENCH: Cet équipment est conforme aux limites d’exposition aux radiations dans un environment
non controle. Cet équipment est en contact direct avec le corps de l’utilisateur dans des conditions de
fonctionnement normales. Cet émetteur ne doit pas être co-localisées ou opérant en conjunction avec tout autre
antenne ou transmetteur.
WIRELESS STANDARD FOOT SWITCH
INSTRUCTIONS
Congratulations on your purchase of the Power-Pole® Standard Foot Switch featuring
C-Monster 2.0 Control System Wireless Technology.
To add the Power-Pole Foot Switch follow these simple step by step instructions.
NOTE: Only compatible with C-Monster 2.0
Hardware:
Installation Tools:
Qty. (1) Up button
Qty. (1) Down button
Qty. (2) #8 x 1&1/2” Pan head screws
Qty. (4) #8 x 1 & ¼” Pan head screws
• #2 Phillips-head screwdriver
• 1/8” drill bit
• Electric or battery operated drill
ENGLISH: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2) this device must not accept
any interference, including interference that may cause undesired operation of the device.
FRENCH: Le présent est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts
de license. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire
de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
To activate your warranty or find a Power-Pole
Certified Warranty Center, go to www.power-pole.com
Hardware missing? Need help? Contact our
Technical Support Team at 1 + 813.689.9932 Option 2
9010 Palm River Road, Tampa, Florida 33619
phone 813.689.9932 fax 813.689.8883 • power-pole.com
©2017 all rights reserved. Power-Pole Shallow Water Anchor U.S. Patent No. 6,041,730
Hardware missing? Need help? Contact our
Technical Support Team at 1 + 813.689.9932 Option 2
Pairing and Operation
Changing the Battery and Installation
Hydraulic Pump Unit (HPU)
Pairing Foot Switchs:
1. Press and hold the PROGRAM button on the top of the HPU
unit for 3 seconds until the LED turns green in color (HPU will
also beep).The unit is now ready to be paired with the foot
switches.
LED
UP button
PROGRAM button
1. Remove the (3) screws with a #2 Phillips-head
screwdriver.
DOWN button
2. Press the UP foot switch button for 1 second and release
FIG. 1 The green LED on the unit will initially turn off, then
flash green steadily (HPU will also beep) indicating that the
pairing is complete.
IMPORTANT: The first time your foot switch is paired to a recently updated pump it may perform
a firmware update. When this occurs the foot switch will blink for approximately one
minute. Please do not interrupt power to either the pump or foot switch during this
process. When the blinking has ceased your foot switch has finished updating and is
ready to use. The pump will not update an unpaired foot switch.
NOTE: If dual units are installed, repeat Steps 1-3 to pair multiple units to a single foot switch.
Up to ten (10) wireless controllers can be programmed to each unit.
3. For the DOWN foot switch button, repeat Step 1 to enter programming mode. Next, press the
DOWN foot switch button for 1 second and release. FIG.2 The green LED on the unit will
initially turn off, then flash green steadily (HPU will also beep) indicating that the pairing
is complete.
4. The foot switches are now paired to the unit. Test their functionality by following the operating
instructions to ensure that the pairing procedure was completed successfully.
Figure 1
Changing the Battery:
Figure 2
2. Take the foot switch to a dry location and separate the
foot switch cover from its base using a small flat head
screwdriver FIG. 1
Figure 1
3. Remove the rubber switch membrane and the circuit
board from the foot switch base FIG. 2
SWITCH COVER
4. Remove the battery from the holder on the back of
the circuit board and replace with any CR2032 3V
Lithium Coin Battery.
CIRCUIT BOARD
5. Inspect the inside of the foot switch case for signs of
moisture or damage to the rubber seal. If the rubber
seal appears damaged, or if moisture is found, please
contact our technical support staff at
813-689-9932 option 2.
Figure 2
CIRCUIT BOARD
6. Place the circuit board back into its base with circuit
board level and small black caps placed over each
circuit board button FIG. 3
BLACK CAPS
NOTE: Each small black cap when pressed should push
down and come up when released. If the black cap
does not push down remove black cap and rotate
1 quarter turn and re-install.
Figure 3
SWITCH COVER
7. Install rubber switch membrane back into the foot
switch base and ensure that the rubber switch
membrane is seated properly prior to installing the
cover FIG. 4
Figure 4
Operating Instructions:
1. To raise or lower the Power-Pole anchor, press and hold either the UP or the DOWN foot switch
button. The anchor will only continue to move so long as you keep the button depressed.
Auto Mode: Double tapping (depressing and releasing 2 times within 1 second) either the UP
or the DOWN foot switch button will cause the anchor to retract or deploy automatically. The
anchor will continue to move in said direction until it either retracts completely (up) or senses a
solid bottom surface (down).
NOTE: The wireless foot switch comes set to 70% speed setting. This can be adjusted by
downloading the C-Monster App and connecting to the system via Bluetooth with your
Android or iOS powered smart phone.
Installation Instructions:
1. Locate a suitable area with a flat surface to mount
the UP and DOWN foot switches.
2. Mark and drill a hole with 1/8” drill bit. Fasten
foot switches using the (6) screws C and D
supplied (do not over tighten).

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Page Count                      : 3
XMP Toolkit                     : 3.1-701
Create Date                     : 2017:06:07 08:01:20-04:00
Modify Date                     : 2017:06:07 08:03:00-04:00
Creator Tool                    : Microsoft Word - 16-2088 - Manual Cover.docx
Metadata Date                   : 2017:06:07 08:03:00-04:00
Document ID                     : uuid:8d8dd9fc-b526-5e9d-72d9-51ebb3588a49
Instance ID                     : uuid:b9807bfa-2014-2d82-f94d-8e0d304d9e96
Producer                        : Nuance PDF Create
Creator                         : geris-je
Title                           : Microsoft Word - 16-2088 - Manual Cover.docx
Author                          : geris-je
EXIF Metadata provided by EXIF.tools
FCC ID Filing: A7FEA071

Navigation menu