JVC KENWOOD 371310 VHF Transmitter User Manual
JVC KENWOOD Corporation VHF Transmitter Users Manual
Contents
- 1. Users Manual
- 2. Users Manual Safety Info
Users Manual
NXR-700/ NXR-800 VHF DIGITAL BASE-REPEATER/ UHF DIGITAL BASE-REPEATER INSTRUCTION MANUAL BASE-RELAIS NUMÉRIQUE VHF/ BASE-RELAIS NUMÉRIQUE UHF MODE D'EMPLOI BASE-REPETIDOR DIGITAL VHF / BASE-REPETIDOR DIGITAL UHF MANUAL DE INSTRUCCTIONES BASE-RIPETITORE DIGITALE VHF/ BASE-RIPETITORE DIGITALE UHF MANUALE DI ISUTRUZIONI VHF DIGITAL BASE-REPEATER/ UHF DIGITAL BASE-REPEATER BEDIENUNGSANLEITUNG VHF DIGITALE BASIS REPEATER/ UHF DIGITALE BASIS REPEATER GEBRUIKSAANWIJZING © B62-XXXX-00 (E) 09 08 07 06 05 04 03 02 01 00 NXR-700 / NXR-800 INSTRUCTION MANUAL VHF DIGITAL BASE-REPEATER / UHF DIGITAL BASE-REPEATER THANK YOU! UNPACKING AND CHECKING EQUIPMENT We are grateful you purchased this Kenwood repeater. We believe this easy-to-program repeater will be highly effective in your communications system, and will keep personnel operating at peak eficiency. Kenwood incorporates the latest in advanced technology into all of our products. As a result, we feel strongly that you will be pleased with the quality and features of this product. Note: The following unpacking information is for use by your Kenwood dealer, an authorized Kenwood service center, or the factory. Carefully unpack the repeater. We recommend that you identify the items listed in the following table before discarding the packing material. If any items are missing or have been damaged during shipment, ile a claim with the carrier immediately. Item PRECAUTIONS • • • • • Front glass Dressed screw Bracket Flat head machine screw Handle and screw set DC cord Lead wire with connector (15 pin) Fuse (15 A) Instruction Manual Do not expose the unit to rain or moisture; to prevent ire or electric shock. Do not open the unit under any circumstances; to avoid risk of electric shock. Do not expose the unit to long periods of direct sunlight, nor place it close to heating appliances. Do not place the unit in excessively dusty and/or humid areas, nor on unstable surfaces. If you detect an abnormal odor or smoke coming from the unit, disconnect the power from the unit immediately. Contact your Kenwood service center or dealer. Part Number Quantity B10-2781-XX N08-0563-XX J29-0725-XX N32-4008-XX K01-0421-XX E30-3344-XX E37-1381-XX F05-1537-XX B62-XXXX-XX INSTALLATION To install the handles onto the front panel of the repeater, align the handles with the holes on the front panel, then secure the handles using the supplied screws. Please consult your dealer for installing the repeater and antenna. NOTICES TO THE USER ◆ Government law prohibits the operation of unlicensed radio transmitters within the territories under government control. ◆ Illegal operation is punishable by ine and/or imprisonment. ◆ Refer service to qualiied technicians only. MICROPHONE Connect an optional KMC-30, KMC-35, or KMC-9C Kenwood microphone to the MICROPHONE jack on the front panel. OCXO UNIT (KXK-3):Option ◆ This repeater is intended for use as a ixed base station with the antenna located outdoors on the rooftop or on an antenna tower. (except U.S.A. and Canada) ◆ This repeater is designed for a 13.2 V DC power source! Never use a 24 V DC or higher source to power the repeater. ◆ Use only the supplied DC cord. ◆ Do not remove the ferrite core attached to the DC cord. Doing so may cause interference with radio communications. The OCXO unit (KXK-3) is an Oven Controlled Crystal Oscillator (OCXO) unit. The AMBE+2 voice coding Technology embodied in this product is protected by intellectual property rights including patent rights, copyrights and trade secrets of Digital Voice Systems, Inc. This voice coding Technology is licensed solely for use within this Communications Equipment. The user of this Technology is explicitly prohibited from attempting to extract, remove, decompile, reverse engineer, or disassemble the Object Code, or in any other way convert the Object Code into a human-readable form. U.S. Patent Nos. #5,870,405, #5,826,222, #5,754,974, #5,701,390, #5,715,365, #5,649,050, #5,630,011, #5,581,656, #5,517,511, #5,491,772, #5,247,579, #5,226,084 and #5,195,166. CONTROLS AND FUNCTIONS ■ Front Panel STATUS 1 2 3 4 5 6 7 8 VOLUME TAKE RPT MON OVER DISABLE CTRL OCXO BUSY TX POWER COM !2 !1 !0 o i q Speaker w CH/STATUS Display Two 17-segment digits display the channel number, name, or status. e STATUS indicator Indicates the status of the repeater. (NXDN mode) r Programmable Function keys Press these keys to activate their programmable functions. t COM jack Connect to the PC using a RS-232C standard DB9 (Female) cross cable. y VOLUME control Turn clockwise until a click sounds, to unmute the audio. Rotate to adjust the audio. Turn counterclockwise fully to mute the audio. u MICROPHONE jack Connect a microphone to this 8-pin modular jack. POWER indicator Lights green when power is supplied to the DC 13.2V jack. Blinks red when an abnormal voltage is present. ■ Rear Panel TEST/SPKR CONTROL I/O SYNC LAN REF OUT OFF/ MICROPHONE While blinking, the repeater cannot be used. o TX indicator Lights red while transmitting. !0 BUSY indicator Lights green while a signal is being received. !1 OCXO indicator The OCXO indicator shows the state of the reference 10 MHz oscillator : Lights Green when using a reference signal from an optional OCXO unit (KXK-3). Lights Orange when using a reference signal from another repeater. Lights red when no reference signal is available or when an error occurs. Does not light when the reference signal is an internal VCXO signal. !2 CTRL indicator The CTRL indicator shows the control channel status while using Digital trunking : Lights Green when the repeater is used as control channel. Blinks Green when using a non-dedicated control channel. FUSE DC 13.2V ⑩ REF IN 15 RX TX FUSE 15A q RX IN jack Connect an RX antenna or a duplexer to this BNC receptacle. w TEST/SPKR jack Test input/output jack. Connect an external speaker to this jack. e CONTROL I/O jack Connect a repeater controller or a remote panel to this DB-25 interface. r SYNC 1 / 2 jack Connect to another repeater to use synchronous frame signaling for digital trunking. t LAN jack Connect to Ethernet. y REF OUT jack Connect to another repeater within the site to supply a reference signal. u REF IN jack Connect from another repeater within the site to receive a reference signal. i FUSE Insert 15 A blade fuse into this fuse holder. o DC 13.2V jack Connect a 13.2 V DC power supply to this jack. ⑩ TX OUT jack Connect a TX antenna or a duplexer to this BNC receptacle. TRANSCEIVER OPERATION REPEATER OPERATION ■ Receive Note: Please consult your dealer for programming the repeater. Due to the frequency stability on the 6.25 kHz bandwidth channel, when operating the repeater using an optional OCXO unit, allow the unit to warm up for 24 hours after turning the power on. After turning on the power, wait for approximately 10 seconds for the VCXO or 5 minutes for the OCXO (when mounting) to warm up. During this time, the CH/STATUS Display will blink. The keys will function when they are pressed. Adjust the volume to your desired level. You may need to readjust the volume if you are having interference while receiving a message from your dispatcher or another member in your leet. The BUSY indicator lights green while a signal is being received. When power is applied to the unit, the POWER indicator lights green. Turn the VOLUME control clockwise until a click sounds, to unmute the audio. Rotate to adjust the audio. Turn the VOLUME control counterclockwise fully to mute the audio. The BUSY indicator lights green while receiving a signal and the TX indicator lights red while transmitting. ■ Transmit 1 Listen to the channel before transmitting, to make sure it is not being used. 2 Press the microphone PTT switch, then speak in your normal speaking voice. The TX indicator lights red while transmitting. 3 When you inish speaking, release the PTT switch. NOTIFICATION This equipment complies with the essential requirements of Directive 1999/5/EC. The use of the warning symbol means the equipment is subject to restrictions of use in certain countries. This equipment requires a licence and is intended for use in the countries as below. NOTIFICATION Cet équipement est conforme aux principales exigences de la Directive 1999/5/CE. signiie que l’équipement L’usage du symbole d’avertissement est soumis à des restrictions d’usage dans certains pays. Cet équipement nécessite un contrat de licence et il est destiné à être utilisé dans les pays ci-dessous. AVISO Este equipo cumple con los requisitos esenciales de la Directiva 1999/5/CE. El uso del símbolo de advertencia signiica que el equipo está sujeto a restricciones de uso en ciertos países. Este equipo requiere una licencia y está destinado para utilizarse en los siguientes países. AT IE SE LT BE IT CH MT DK LI GB PL FI LU CY SK FR NL CZ SI DE NO EE BG GR PT HU RO IS ES LV ISO3166 AVVISO La presente apparecchiatura è conforme ai requisiti fondamentali della Direttiva 1999/5/CE. L’uso del simbolo di avvertenza indica che l’apparecchiatura è soggetta alle limitazioni d’uso in vigore in determinati paesi. Questa apparecchiatura e’concepita per essere utilizzata in tutti L’apparecchiatura deve essere provvista di licenza e n’è consentito l'uso nei seguenti paesi. HINWEIS Dieses Gerät erfüllt die grundlegenden Anforderungen der Direktive 1999/5/EG. be-deutet, dass dieses Gerät in manchen Ländern Das Alert-Zeichen bestimmten Verwendung-seinschränkungen unterliegt. Für dieses Gerät ist eine Lizenz erforderlich; es ist für die Verwendung in den unten aufgeführten Ländern vorgesehen. KENNISGEVING Deze apparatuur voldoet aan de vereisten van Richtlijn 1999/5/EG. Het gebruik van het waarschuwings-symbool betekent dat dit apparaat in bepaalde landen aan gebruiksbe-perkingen onderhevig is. Voor deze apparatuur is een licentie nodig en is bedoeld voor gebruik in onderstaande landen. AT BE DK FI FR DE GR IS IE IT LI LU NL NO PT ES SE CH GB CY CZ EE HU LV LT MT PL SK SI BG RO ISO3166 One or more of the following statements may be applicable: FCC WARNING This equipment generates or uses radio frequency energy. Changes or modiications to this equipment may cause harmful interference unless the modiications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modiication is made. INFORMATION TO THE DIGITAL DEVICE USER REQUIRED BY THE FCC This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can generate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer for technical assistance. B59-2669-00 Addendum Terminal Description Control I/O (D-SUB 25 Pin) CONNECTOR MIC (Modular Jack) Pin NO. Pin Name NC Description Specification I/O Notes Pin NO. Pin Name Description Specification I/O Not used Not used − NC Not used Not used − Notes SB Power Output 13.8 V NC Not used Not used − GND GND GND − NC Not used Not used − PTT PTT Signal Input Impedance 100 kΩ AI1 Programmable Function Input 1 Input Impedance 47 kΩ MICG MIC GND MIC GND − AI2 Programmable Function Input 2 Input Impedance 47 kΩ MIC MIC Input 600 Ω AI3 Programmable Function Input 3 Input Impedance 47 kΩ HOOK Hook Detection Input Impeadance 100 kΩ DG Digital GND Digital GND − NC Not used Not used − TD TX Audio Input Input Impedance 600 Ω not Pre-emphasis TA TX Audio Input Input Impedance 600 Ω Pre-emphasis 10 RD RX Audio Output Load Impedance 4.7 kΩ not De-emphasis 11 RX Audio Output Load Impedance 4.7 kΩ De-emphasis 12 RXG RX Signal GND RX Signal GND − 13 SPM Speaker Mute Input Impedance 47 kΩ 14 BER CLK For Bit Error Rate Clock CMOS 15 EMON External Monitor Switch Input Impedance 47 kΩ 16 EPTT External PTT Switch Input Impedance 47 kΩ 17 SC Squelch Control Output level 0 or 3.3 V COM (D-SUB 9 Pin) CONNECTOR Pin NO. Pin Name CD Description Carrier Detect Specification Conform to RS-232C standard I/O Notes RD Receive Data Conform to RS-232C standard SD Send Data Conform to RS-232C standard DTR Data Terminal Ready Conform to RS-232C standard SG GND GND − DSR Data Set Ready Conform to RS-232C standard RTS Request to Send Conform to RS-232C standard CTS Clear to Send Conform to RS-232C standard CI Ringer DET Conform to RS-232C standard TEST/ SPEAKER CONNECTOR Pin NO. Pin Name Description Specification I/O SB Power Output 13.8 V SB Power Output 13.8 V NC Not used Not used − GND GND GND − GND GND GND − SPG Speaker GND Speaker GND − RD RX Audio Output Load impedance 4.7 kΩ RSSI RSSI Signal Output Output Level 0 to 5 V SPI Internal Speaker Input Short with "SPO" 10 AO1 Open Collector Terminal Allowable current value MAX 200mA 11 Open Collector Terminal Allowable current value MAX 200mA AO2 12 SPO External Speaker Output Output Level 3W (5%Distortion) 13 AO3 Open Collector Terminal Allowable current value MAX 200mA 14 AO4 Open Collector Terminal Allowable current value MAX 200mA 15 AO5 Open Collector Terminal Allowable current value MAX 200mA Notes RA 18 BER DAT For Bit Error Rate Data CMOS 19 TXG TX Signal GND TX Signal GND 20 IO1 Programmable Function I/O 1 Input Impedance 47 kΩ I/O Output level 0 or 5 V 21 IO2 Programmable Function I/O 2 Input Impedance 47 kΩ I/O Output level 0 or 5 V 22 IO3 Programmable Function I/O 3 Input Impedance 47 kΩ I/O Output level 0 or 5 V 23 IO4 Programmable Function I/O 4 Input Impedance 47 kΩ I/O Output level 0 or 5 V 24 IO5 Programmable Function I/O 5 Input Impedance 47 kΩ I/O Output level 0 or 5 V 25 IO6 Programmable Function I/O 6 Input Impedance 47 kΩ I/O Output level 0 or 5 V − LAN (Modular Jack) Pin NO. not De-emphasis Pin Name Description Specification I/O Notes TD+ TX Signal + Comform to IEEE802.3 standard 100 Mbps TD- TX Signal − Comform to IEEE802.3 standard 100 Mbps RD+ RX Signal + Use Designated Transformer 100 Mbps NC Not used Not used − NC Not used Not used − RD- RX Signal − Use Designated Transformer NC Not used Not used − NC Not used Not used − 100 Mbps SYNC 1, 2 Connector (There are two connectors) Pin NO. Pin Name Description Specification FRMA RS-485 Differential Signal A Conform to RS485 NC Not used Not used NC Not used Not used FRMB RS-485 Differential Signal B Conform to RS485 RX ANT TX ANT Impedance 50 Ω Impedance 50 Ω REF IN REF OUT External Reference Signal Input (10 MHz). Impedance : more than 1 kΩ Reference Signal Distribution (10 MHz). Load Impedance : more than 20 Ω I/O Notes I/O − − I/O B59-2539-00 Addendum Description de la borne CONNECTEUR Commande E/S (D-SUB 25 broches) MIC (Prise modulaire) N° de broche Nom de broche Description Caractéristiques E/S Remarques N° de broche Nom de broche Description Caractéristiques E/S Remarques Non utilisé − NC Non utilisé Non utilisé − Puissance développée 13,8 V NC Non utilisé Non utilisé − GND (terre) GND (terre) − NC Non utilisé Non utilisé − Signal PTT (poussez-pour-parler) Impédance entrée 100 kΩ AI1 Entrée fonction programmable 1 Impédance entrée 47 kΩ MICG MIC GND MIC GND − AI2 Entrée fonction programmable 2 Impédance entrée 47 kΩ MIC Entrée MIC 600 Ω AI3 Entrée fonction programmable 3 Impédance entrée 47 kΩ HOOK Détection de support Impédance entrée 100 kΩ DG GND numérique GND numérique − NC Non utilisé Non utilisé − TD TX Entrée audio Impédance entrée 600 Ω pas de pré-accentuation TA TX Entrée audio Impédance entrée 600 Ω Pré-accentuation 10 RD RX Sortie Audio Impédance de charge 4,7 kΩ pas de désaccentuation 11 RA RX Sortie Audio Impédance de charge 4,7 kΩ Désaccentuation 12 RXG GND Signal RX GND Signal RX − 13 SPM Haut parleur en sourdine Impédance entrée 47 kΩ 14 BER CLK Pour l'horloge des taux d'erreur sur les bits CMOS NC SB GND PTT Non utilisé CONNECTEUR COM (D-SUB 9 broches) N° de broche Nom de broche Description Caractéristiques Conforme au standard RS-232C E/S CD Détection de porteuse RD Réception de données Conforme au standard RS-232C SD Emission de données Conforme au standard RS-232C DTR Terminal de données prêt Conforme au standard RS-232C SG GND (terre) GND (terre) − DSR Poste de données prêt Conforme au standard RS-232C RTS Demande pour émettre Conforme au standard RS-232C CTS Voie libre Conforme au standard RS-232C CI Tonalité DET Conforme au standard RS-232C Remarques CONNECTEUR TEST/MICROPHONE N° de broche Nom de broche Description Puissance développée Caractéristiques E/S SB SB NC GND GND SPG Haut parleur GND Haut parleur GND − RD RX Sortie Audio Impédance de charge 4,7 kΩ RSSI RSSI Sortie signal Niveau de sortie 0 à 5 V SPI Entrée haut parleur interne Court avec "SPO" 10 AO1 Borne de collecteur ouvert Valeur de courant admissible 200mA 11 AO2 Borne de collecteur ouvert Valeur de courant admissible 200mA 12 SPO Sortie haut parleur externe 13 AO3 Borne de collecteur ouvert 14 AO4 Borne de collecteur ouvert Valeur de courant admissible 200mA 15 AO5 Borne de collecteur ouvert Valeur de courant admissible 200mA Remarques 15 EMON Commutateur de moniteur externe Impédance entrée 47 kΩ 16 EPTT Commutateur PTT externe Impédance entrée 47 kΩ 17 SC Commande du silencieux Niveau de sortie 0 ou 3,3 V 18 BER DAT Pour les données des taux d'erreur sur les bits CMOS 19 TXG GND Signal de transmission GND Signal de transmission 20 IO1 Fonction programmable E/S 1 Impédance entrée 47 kΩ E/S Niveau de sortie 0 ou 5 V 21 IO2 Fonction programmable E/S 2 Impédance entrée 47 kΩ E/S Niveau de sortie 0 ou 5 V − 22 IO3 Fonction programmable E/S 3 Impédance entrée 47 kΩ E/S Niveau de sortie 0 ou 5 V 23 IO4 Fonction programmable E/S 4 Impédance entrée 47 kΩ E/S Niveau de sortie 0 ou 5 V 24 IO5 Fonction programmable E/S 5 Impédance entrée 47 kΩ E/S Niveau de sortie 0 ou 5 V 25 IO6 Fonction programmable E/S 6 Impédance entrée 47 kΩ E/S Niveau de sortie 0 ou 5 V 13,8 V Puissance développée 13,8 V Non utilisé Non utilisé − GND (terre) GND (terre) − N° de broche GND (terre) GND (terre) − TD+ TD- Signal − TX Comforme au standard IEEE802.3 100 Mbps RD+ Signal + RX Utiliser le transformateur désigné 100 Mbps NC Non utilisé Non utilisé − NC Non utilisé Non utilisé − RD- Signal − RX Utiliser le transformateur désigné NC Non utilisé Non utilisé − Niveau de sortie 3W (Distorsion 5%) NC Non utilisé Non utilisé − Valeur de courant admissible 200mA LAN (Prise modulaire) pas de désaccentuation Nom de broche Description Signal + TX Caractéristiques Comforme au standard IEEE802.3 E/S Remarques 100 Mbps 100 Mbps Connecteurs SYNC 1, 2 (Il y a deux connecteurs) N° de broche Nom de broche Description Caractéristiques FRMA Signal Différentiel A RS-485 Conforme au RS485 NC Non utilisé Non utilisé NC Non utilisé Non utilisé FRMB Signal Différentiel B RS-485 Conforme au RS485 RX ANT TX ANT Impédance 50 Ω Impédance 50 Ω REF IN REF OUT Entrée signal de référence externe (10 MHz). Impédance : supérieure à 1 kΩ Distribution signal de référence (10 MHz). Impédance de charge : supérieure à 20 Ω E/S Remarques E/S − − E/S B59-2539-00 B59-2539-00_NXR-700-800_French.iA A 2008/02/21 10:18:29 MANDATORY SAFETY INSTRUCTIONS TO INSTALLERS AND USERS • Use only manufacturer or dealer supplied antennas. • Antenna Minimum Safe Distance: 180 cm (6 feet). • Antenna Gain: 0 dBd referenced to a dipole. The Federal Communications Commission has adopted a safety standard for human exposure to RF (Radio Frequency) energy which is below the OSHA (Occupational Safety and Health Act) limits. • Antenna Mounting: The antenna supplied by the manufacturer or radio dealer must not be mounted at a location such that during radio transmission, any person or persons can come closer than the above indicated minimum safe distance to the antenna, i.e. 180 cm (6 feet). • To comply with current FCC RF Exposure limits, the antenna must be installed at or exceeding the minimum safe distance shown above, and in accordance with the requirements of the antenna manufacturer or supplier. • Vehicle installation: The antenna can be mounted at the center of a vehicle metal roof or trunk lid, if the minimum safe distance is observed. • Base Station Installation: The antenna should be ixed-mounted on an outdoor permanent structure. RF Exposure compliance must be addressed at the time of installation. Antenna substitution: Do not substitute any antenna for the one supplied or recommended by the manufacturer or radio dealer. You may be exposing person or persons to excess radio frequency radiation. You may contact your radio dealer or the manufacturer for further instructions. Maintain a separation distance from the antenna to person(s) of at least 180 cm (6 feet). You, as the qualiied end-user of this radio device must control the exposure conditions of bystanders to ensure the minimum separation distance (above) is maintained between the antenna and nearby persons for satisfying RF Exposure compliance. The operation of this transmitter must satisfy the requirements of Occupational/Controlled Exposure Environment, for work-related use, transmit only when person(s) are at least the minimum distance from the properly installed, externally mounted antenna. Transmit only when people outside the vehicle are at least the recommended minimum lateral distance away from the antenna/vehicle. B59-2667-00
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Create Date : 2011:05:20 10:22:05+09:00 Creator : Adobe InDesign CS2_J (4.0.5) Modify Date : 2011:06:07 10:30:28-04:00 Title : Trapped : False XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2011:06:07 10:30:28-04:00 Creator Tool : Adobe InDesign CS2_J (4.0.5) Format : application/pdf Document ID : uuid:28dabc03-8f21-4c8c-b3d4-37759402540e Instance ID : uuid:1572daee-c99d-4dfa-b6ba-9f759869e28b Producer : Adobe PDF Library 7.0 Page Count : 8EXIF Metadata provided by EXIF.tools