Jacuzzi J 280 User Manual To The Ed8f074a 927f 4927 B6e4 75c0ef49c33b

User Manual: Jacuzzi J-280 to the manual

Open the PDF directly: View PDF PDF.
Page Count: 60

DownloadJacuzzi J-280 User Manual  To The Ed8f074a-927f-4927-b6e4-75c0ef49c33b
Open PDF In BrowserView PDF
owner’s manual

J-200™

J - 280
J - 270
J - 230
J - 210
2530-277U Rev. C

Series

Attention New Spa Owner!®

Congratulations on the purchase of your new Jacuzzi spa! The following
is a list of automated functions performed by your spa. These functions are
listed below in an attempt to alleviate any operational concerns you may
have during the first 24-hours of ownership! Also listed below are important
maintenance recommendations you should observe on a regular basis to
protect your new investment.
Automated Operations
Approximately two minutes after power is applied to the spa, the first
filtration/heating cycle turns on pump 1. With models J-270 and J-280 an
automatic five minute “blow-out” function also activates pump 2 for a period
of five minutes to flush all lines. Then, after five minutes, pump 2 turns off
and pump 1 continues to operate for the duration of the cycle.

Note: This function only occurs during the first filtration/heating cycle
each day.
Maintain Healthy Spa Water
Always maintain your spa’s water chemistry within the following parameters
as defined by the Association of Pool And Spa Professionals/USA:
pH

7.4-7.6

Free Chlorine

3.0-4.0 ppm

Free Bromine

2.0-4.0 ppm

Total Alkalinity

100-120 ppm

Calcium Hardness

150-250 ppm

!

TO DECREASE RISK OF INFECTION OR DISEASE! Always maintain
your spas filter as outlined below to ensure healthy spa water. Refer page 37
“Water Quality Maintenance” for additional information.
Required Filter Maintenance
Your new spa is equipped with an advanced water filtration system that
provides unsurpassed water quality! To ensure maximum water quality at
all times, you should clean the filter cartridge once a month, or earlier as
necessary. See page 32 for detailed filter cartridge cleaning/replacement
instructions.
Required Water Replacement
! TO DECREASE RISK OF INFECTION OR DISEASE! You should
replace the spa’s water every 3 months. The frequency depends on a number
of variables including frequency of use, number of users, and attention paid to
water quality maintenance. You will know it is time for a change when you
cannot control sudsing and/or you can no longer get the normal feel or
sparkle to the water, even though the key water balance measurements are
all within the proper parameters. See page 37 for additional information.

Table of Contents
1.0
2.0

Important Spa Owner Information���������������������������������������������� 1
FCC Notice����������������������������������������������������������������������������������� 1

3.0
3.1
3.2
3.3
3.4

Important Safety Instructions for all Spa Owners�������������������� 2
Entrapment Risk���������������������������������������������������������������������������� 6
Hyperthermia��������������������������������������������������������������������������������� 7
Important CSA Safety Instructions (Canada Only)������������������������ 8
General Electrical Safety Instructions�������������������������������������������� 8

4.0
4.1
4.2

Choosing A Location������������������������������������������������������������������� 9
Outdoor Location������������������������������������������������������������������������� 10
Indoor Location���������������������������������������������������������������������������� 10

5.0
6.0
7.0
8.0

General Electrical Safety Instructions������������������������������������� 12
Power Requirements����������������������������������������������������������������� 13
Electrical Wiring Instructions��������������������������������������������������� 16
Spa Fill Up Procedure��������������������������������������������������������������� 19

9.0
9.1
9.2

Control Functions���������������������������������������������������������������������� 24
Control Panel������������������������������������������������������������������������������� 24
General Spa Features and Controls�������������������������������������������� 25

10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7

Operating Instructions�������������������������������������������������������������� 26
Setting Water Temperature ��������������������������������������������������������� 26
Activate Jet Pumps���������������������������������������������������������������������� 26
Standard Light Operation������������������������������������������������������������ 26
Optional Multi-Colored LED Light System Operation������������������ 27
Adjusting Individual Jet Flow������������������������������������������������������� 27
Selecting Desired Massage Action���������������������������������������������� 27
Air Controls���������������������������������������������������������������������������������� 28

11.0
11.1

Automatic Filtration Cycles������������������������������������������������������ 28
Standard Filtration/Heating Modes For Models Without
Circulation Pump Option (All Models)������������������������������������������ 28
Standard Filtration/Heating Modes For Models With
Circulation Pump Option (J-230, J-270 and J-280 Only)������������� 28
Economy Filtration/Heating Modes (All Models)�������������������������� 29
Lock Modes - L1-L2 (All Models)������������������������������������������������� 29
Selecting The Filtration/Heating Mode���������������������������������������� 29
Filtration Modes for Spas Without Circulation Pump
Option (All Models)���������������������������������������������������������������������� 29
Filtration Modes for Spas With Circulation Pump
Option (J-230, J‑270 and J-280 Only)����������������������������������������� 30

11.2
11.3
11.4
11.5
11.6
11.7

© 2009 Jacuzzi Hot Tubs, Inc. All Rights Reserved

12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8

Spa Maintenance����������������������������������������������������������������������� 32
Cleaning The Filters�������������������������������������������������������������������� 32
Draining and Refilling������������������������������������������������������������������ 35
Pillow Care���������������������������������������������������������������������������������� 35
Cleaning The Spa Interior������������������������������������������������������������ 36
Maintaining the Cover������������������������������������������������������������������ 36
Maintaining The Synthetic Cabinet���������������������������������������������� 36
Winterizing����������������������������������������������������������������������������������� 36
Restarting Your Spa in Cold Weather������������������������������������������ 37

13.0
13.1
13.2
13.3

Water Quality Maintenance������������������������������������������������������� 37
pH Control����������������������������������������������������������������������������������� 38
Sanitizing������������������������������������������������������������������������������������� 38
Optional CD Ozone Water Maintenance System������������������������ 39

14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.9

Error Conditions/Error Messages�������������������������������������������� 39
Summer Logic (Spas With Circulation Pump Option)������������������ 39
Panel Displays COL��������������������������������������������������������������������� 39
Panel Displays ICE���������������������������������������������������������������������� 40
Panel Displays SN1��������������������������������������������������������������������� 40
Panel Displays SN2��������������������������������������������������������������������� 40
Panel Flashes FL1 or FL2 (Spas Without Circulation Pump
Option)����������������������������������������������������������������������������������������� 40
Panel Flashes FL1 or FL2 (Spas With Circulation Pump Option)���� 40
Panel Displays OH���������������������������������������������������������������������� 41
Panel Displays (- - -)�������������������������������������������������������������������� 41

15.0
15.1
15.2
15.3
15.4
15.5

Troubleshooting Procedures���������������������������������������������������� 42
None of the Components Operate (e.g. Pump, Light) ���������������� 42
Pump Does Not Operate But Light Does������������������������������������� 42
Poor Jet Action���������������������������������������������������������������������������� 42
Water is Too Hot�������������������������������������������������������������������������� 42
No Heat��������������������������������������������������������������������������������������� 43

16.0
16.1
16.2
16.3
16.4

Circuit Board Diagrams ����������������������������������������������������������� 44
North American J-230, J-270 and J-280 Models������������������������� 44
North American J-210 Convertible Models���������������������������������� 45
Export 50 Hz J-230, J-270 and J-280 Models����������������������������� 46
Export 50 Hz J-210 Models��������������������������������������������������������� 47

17.0

Optional Stereo Receiver Functions���������������������������������������� 48

J-200 Series
1.0

Important Spa Owner Information

Your Jacuzzi® J-200 series spa is constructed to the highest standards
and is capable of providing many years of trouble-free use. However,
because heat retentive materials are utilized to insulate the spa for
efficient operation, an uncovered spa surface directly exposed to sunlight
and high temperatures for an extended period is subject to permanent
damage. Damage caused by exposing the spa to this abuse is not
covered under warranty. We recommend that you always keep the spa
full of water when it is exposed to direct sunlight and that you keep the
Jacuzzi premium insulating cover in place at all times when the spa is not
in use. Read and carefully follow the requirements for your spa’s support
base found in section 4.0 titled, “Choosing A Location” (page 9).
Jacuzzi constantly strives to offer the finest spas available,
therefore modifications and enhancements may be made which
affect the specifications, illustrations and/or instructions contained
herein.

2.0

FCC Notice

This equipment has been tested and found to comply with the limits for
a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
1. Rearrange or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver
3. Connect the equipment into an outlet on a circuit different from the
circuit connected.
4. Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party
responsible for FCC compliance could void the user’s authority to
operate this equipment.

1

J-200 Series
3.0

Important Safety Instructions for all Spa Owners

READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY!
This spa was manufactured to meet the standards and specifications
outlined in the “Virginia Graeme Baker Pool and Spa Safety Act” (VGB
Safety Act). When installing and using this spa, basic safety precautions
should always be followed, including:
! DANGER: Risk of Severe Injury or Drowning!
1.
• Extreme caution must be exercised to prevent unauthorized access by
children.
• To avoid accidents, ensure that children do not use this spa unless
supervised at all times. Adult supervision is a critical safety factor in
preventing children from drowning.
• Use the straps and clip tie downs to secure the spa cover when not in
use. This will help discourage unsupervised children from entering the
spa. Keep the spa cover secure in high-wind conditions.
• There is no representation that the cover, clip tie-downs, or actual locks
will prevent access to the spa.
! DANGER: Risk of Severe Injury or Drowning!
2.
• Keep hair, loose articles of clothing or hanging jewelry away from
suction fittings, rotating jets or other moving components to avoid
entrapment that could lead to drowning or severe injury.
• Never use the spa unless all suction guards, filter, filter lid, or skimmer
assembly are installed to prevent body and/or hair entrapment.
• Never operate or use the spa if the filter, filter lid, or skimmer assembly
are broken or any part of the skimmer assembly is missing. Please
contact your dealer or nearest service center for service.
• The suction fittings and suction covers in this spa are sized to match the
specific water flow created by the pump(s). If it is necessary to replace
the suction fittings, suction covers or pump(s), be sure that the flow
rates are compatible and are in compliance with the VGB Safety Act.
• Never replace a suction fitting or suction cover with one rated less
than the flow rate marked on the original suction fitting. Using improper
suction fittings or suction covers can create a body or hair suction
entrapment hazard that may lead to drowning or severe injury.

3.
•

2

DANGER: Risk of Severe Injury from Electric
Shock or Death from Electrocution!
Install the spa at least 5 feet (1.5m), from all metal surfaces. As an
alternative, a spa may be installed within 5 feet of metal surfaces if each
metal surface is permanently connected (bonded) by a minimum No. 8
AWG (8.4 mm²) solid copper conductor attached to the wire connector
on the grounding lug, inside the equipment compartment on the
equipment box.
!

J-200 Series
•

•
•
•
•

•

A grounding wire connector is provided on this unit to connect a
minimum No. 8 AWG (8.4 mm²) solid copper conductor between this
unit and any metal equipment, metal enclosures of electrical equipment,
metal water pipe, or conduit within 5 feet (1.5m) of the unit.
Never permit any electrical appliance, such as a light, telephone, radio,
television, etc. within 5 feet (1.5m) of a spa unless such appliances are
built-in by the manufacturer.
Never bring any electrical appliances into or near the spa.
Never operate any electrical appliances from inside the spa or when you
are wet.
The electrical supply for this product must include a suitably rated switch
or circuit breaker to open all ungrounded supply conductors to comply
with section 422-20 of the National Electrical Code/USA, ANSI/NFPA 70.
The disconnecting means must be readily accessible and visible to the
spa occupant but installed at least 5 feet (1.5m), from the spa.
The electrical circuit supplied for the hot tub must include a suitable
ground fault circuit interrupter (GFCI) as required by NEC Article 680-42.

! WARNING: Risk of Severe Injury or Death!
4.
• Extreme caution must be exercised to prevent diving or jumping into
the spa or slipping and falling, which could result in unconsciousness,
drowning, or serious injury. Remember that wet surfaces can be very
slippery.
• Never stand, walk or sit on the top railing of the spa.

5.
•
•
•
•
•
•

!

WARNING: Risk of Hyperthermia (over-heating)
Causing Severe Injury, burns, welts or Death!
Water temperature in excess of 104°F (40°F) may be injurious to your
health.
Refer to section 3.2 Hyperthermia for specific causes and symptoms of
this condition.
The water in the spa should never exceed 104°F (40°C). Water
temperatures between 100°F (38°C) and 104°F (40°C) are considered
safe for a healthy adult.
Lower water temperatures are recommended for young children
(children are especially sensitive to hot water) and when spa use may
exceed 10 minutes.
The Consumer Products Safety Commission/USA has stated that the
water temperature in a spa should not exceed 104°F (40°C).
Always test the spa water temperature before entering the spa.
The user should measure the water temperature with an accurate
thermometer since the tolerance of water temperature-regulating
devices may vary as much as +/- 5°F (2°C).

3

J-200 Series
! WARNING: Risk of Severe Injury or Death!
6.
• Since excessive water temperatures have a high potential for causing
fetal damage during the early months of pregnancy, if pregnant or
possibly pregnant, consult your physician before using a spa.
• Pregnant or possibly pregnant women should limit spa water
temperatures to 100°F (38°C).
• Persons suffering from obesity or a medical history of heart disease,
low or high blood pressure, circulatory system problems, diabetes,
infectious diseases or immune deficiency syndromes should consult a
physician before using a spa.
• If you experience breathing difficulties in association with using or
operating your spa, discontinue use and consult your physician.
• Persons using medication should consult a physician before using
a spa since some medication may induce drowsiness, while other
medication may affect heart rate, blood pressure, and circulation.
• Persons suffering from any condition requiring medical treatment, the
elderly, or infants should consult with a physician before using a spa.
• The use of alcohol, drugs, or medication before or during spa use may
lead to unconsciousness with the possibility of drowning.
! WARNING: Risk of Severe Injury or Death!
7.
• Prolonged immersion in a spa may be injurious to your health.
• Observe a reasonable time limit when using the spa. Exposures at
higher temperatures can cause high body temperature (over-heating).
Symptoms may include dizziness, nausea, fainting, drowsiness, and
reduced awareness. These effects could possibly result in drowning or
serious injury.
• Never use a spa immediately following strenuous exercise. Enter and
exit the spa slowly. Wet surfaces can be slippery.

8.
•

•
•

4

! WARNING: To Decrease Risk of Infection or
Disease!
To reduce the risk of contracting a waterborne illness (e.g. an infection,
bacteria or virus) and/or respiratory ailments, maintain water chemistry
within the parameters listed on the inside cover of this manual and
consult with a licensed engineer regarding proper ventilation if installed
indoors or in an enclosed area.
People with infectious diseases should not use a spa to avoid water
contamination, which could result in spreading infections to others.
Always shower before and after using your spa. Maintain water chemistry in accordance with manufacturer’s instructions. Failure to do
so may result in contracting a waterborne illness (e.g. an infection,
bacteria or virus).

J-200 Series
9. CAUTION: To DECREASE Risk of Product Damage.
• Maintain water chemistry in accordance with manufacturer’s
instructions.
• Proper chemical maintenance of spa water is necessary to maintain
safe water and prevent possible damage to spa components.
10.	NOTE:
This spa is not intended nor designed to be used in a commercial or
public application. The spa buyer shall determine whether there are any
code restrictions on the use or installation of this spa since local code
requirements vary from one locality to another.

Hot Tub Safety Literature

To ensure you have a safe and enjoyable hot tub experience,
learn all you can about hot tub safety and emergency procedures.
Especially useful are the brochures listed below:
• Children Aren’t Waterproof
• Pool and Spa Emergency Procedures For Infants and Children
• Layers of Protection
• The Sensible Way to Enjoy Your Spa or Hot Tub
The Association of Pool and Spa Professionals publishes these
brochures. To acquire a brochure:
• Ask your hot tub dealer (they may have copies)
• Go to http://apsp.org
• Conduct your own search on the internet
• Write to the following address:
The Association of Pool and Spa Professionals
2111 Eisenhower Avenue
Alexandria VA 22314
703.838.0083

5

J-200 Series
3.1	Entrapment Risk
The Consumer Products Safety Commission/USA has reported that
users of pools and spas have become entrapped (stuck) to drain and/or
suction fittings causing death, drowning, or serious injury (see diagram
below). This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act”
(VGB Safety Act). Entrapment risk can be minimized if proper precautions are taken.

!

DANGER:

RISK OF PERSONAL INJURY OR DEATH!
Never operate the spa if a suction fitting, suction cover,
filter, filter lid or skimmer assembly are broken, damaged or
missing.
Filter, Filter
Lid, Skimmer
Assembly
(location and
style vary by
models)

Suction Fittings,
Suction Covers
(locations vary
by models)

1.

•
•
•

! DANGER: Risk of Severe Injury or Drowning!
Hair entrapment: May occur if hair is entangled, knotted or snagged
in a drain suction or skimmer assembly. This has been reported in
persons who when submerge themselves underwater, allowing hair
to come close and/or within the reach of the suction fittings, suction
covers or skimmer assembly.
Keep hair away from suction fittings, suction covers, filter, filter lid or
skimmer assembly.
Children are at risk for hair entrapment if swimming under water.
Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.

! DANGER: Risk of Severe Injury or Drowning!
2.
	Limb entrapment: May occur when a limb becomes entrapped,
inserted or sucked into a suction or outlet opening.
• Always keep suction fittings, suction covers, filter, filter lid or skimmer
assembly in place when operating to avoid limb entrapment.
• Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.

6

J-200 Series
3.
•

! DANGER: Risk of Severe Injury or Drowning!
Body entrapment: May occur when part of the torso becomes
entrapped, inserted or sucked into a suction or outlet opening.
Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.

! DANGER: Risk of Severe Injury or Drowning!
4.
	Evisceration (disembowelment) entrapment: May occur when the
buttocks becomes entrapped, inserted or sucked into a suction or
outlet opening.
• Never sit on suction fittings, suction covers, filter, filter lid or skimmer
assembly.
• Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.
! DANGER: Risk of Severe Injury or Drowning!
5.
	Mechanical entrapment: May occur when jewelry, swimsuit, or
hair accessories become entangled, knotted or snagged in a drain
suction or skimmer assembly.
• Never allow your jewelry, swimsuit, or hair accessories to come close
to the suction fittings, suction covers or skimmer assembly.
• Never allow children to play or get near the suction fittings, suction
covers, filter, filter lid or skimmer assembly.

3.2
Hyperthermia
Prolonged immersion in hot water may induce hyperthermia (overheating). The use of alcohol or drugs can greatly increase the risk of fatal
hyperthermia in spas. A description of the causes, symptoms, and effects
of hyperthermia are as follows:
Hyperthermia occurs when the internal temperature of the body reaches
a level several degrees above the normal body temperature of 98.6°F
(37°C). The symptoms of hyperthermia include drowsiness, lethargy
(fatigue), and an increase in the internal temperature of the body. The
effects of hyperthermia include:
•
•
•
•
•
•

Unawareness of impending hazard;
Failure to perceive heat;
Failure to recognize the need to exit spa;
Physical inability to exit spa;
Fetal damage in pregnant women; and
Unconsciousness and DANGER of drowning.
A Warning Sign is provided in your warranty packet. Please install at
a location near your spa, where it is visible to users of the spa. For
additional or replacement Warning Signs please contact your local
Jacuzzi dealer and reference item number #6530-082.

7

J-200 Series
3.3
Important CSA Safety Instructions (Canada Only)
When using this electrical equipment, basic safety precautions should
always be followed, including the following:
1.	 READ AND FOLLOW ALL INSTRUCTIONS.
2. A green colored terminal or a terminal marked G, Gr, Ground,
Grounding or the
symbol* is located inside the supply terminal box
or compartment. To reduce the risk of electric shock, this terminal
must be connected to the grounding means provided in the electric
supply service panel with a continuous copper wire equivalent in size
to the circuit conductors that supply this equipment (*IEC Publication
417, Symbol 5019).
3. At least two lugs marked “Bonding Lugs” are provided on the
external surface or on the inside of the supply terminal box/
compartment. To reduce the risk of electric shock, connect the local
common bonding grid in the area of the spa to these terminals with
an insulated or bare copper conductor not smaller than No. 6 AWG
(10 mm²).
4. All field installed metal components such as rails, ladders, drains or
other similar hardware within 10 feet (3m) of the spa shall be bonded
to the equipment grounding buss with copper conductors not smaller
than No. 6 AWG (10 mm²).
5. SAVE THESE INSTRUCTIONS.
3.4
General Electrical Safety Instructions
Your new Jacuzzi® spa is equipped with a “state-of-the-art” equipment
system. It contains the most advanced safety and self-protective
equipment in the industry. Nonetheless, this spa must be installed
properly to ensure dependable usage. Please contact your local Jacuzzi
dealer or local building department should you have any questions
regarding your installation.
Proper grounding is extremely important. Jacuzzi spas are equipped with
a current collector system. A pressure wire connector is provided on the
surface of the control box, located outside the equipment door (Figure
B, page 17) to permit connection of a bonding wire between this point
and any ground metal equipment, metal water pipe or conduit within 5
feet (1.5m) of the spa, or copper clad grounding rod buried within 5 feet
(1.5m) of the spa. Bonding wire must be at least No. 8 AWG (8.4 mm²)
solid copper wire. This is a most important safety assurance feature.
Before installing your spa, check with your local building department to
insure installation conforms to local building codes.

8

J-200 Series
4.0

Choosing A Location

IMPORTANT: Because of the combined weight of the spa, water and
users, it is extremely important that the base upon which the spa rests
be smooth, flat, level and capable of uniformly supporting this weight,
without shifting or settling, for the entire time the spa is in place. If the
spa is placed on a surface which does not meet these requirements,
damage to the skirt and/or the spa shell may result. Damage caused by
improper support is not covered under warranty. It is the responsibility
of the spa owner to assure the integrity of the support at all times.
We recommend a poured, reinforced concrete slab with a minimum
thickness of 4 inches (10 cm). Wood decking is also acceptable
provided it is constructed so that it meets the requirements outlined
above.

!

WARNING: For spas that are to rest on balconies,

roofs or other platforms not specifically tied into main
structural support, consult a professional Structural
Engineer with experience in this type of application.

The spa must be installed in such a manner as to provide drainage away
from it. Placing the spa in a depression without provisions for proper
drainage could allow rain, overflow and other casual water to flood the
equipment and create a wet condition in which it would sit in. For spas
which will be recessed into a floor or deck, install so as to permit access
to the equipment, either from above or below, for servicing. Make certain
that there are no obstructions which would prevent removal of all side
cabinet side panels and access to the jet components, especially on the
side with the equipment bay.
!

Caution: If the spa is indoors or located in an enclosed area,

proper ventilation should be discussed with an Engineer or authority
competent enough to understand the necessary provisions needed
to vent moist or heated air and air associated with chemical odors
outdoors. When the spa is in use considerable amounts of moisture
will escape potentially causing mold and mildew. This can cause
health risk. Over time, this can damage certain surfaces,
surroundings, and equipment.

9

J-200 Series
4.1	Outdoor Location
In selecting the ideal outdoor location for your spa, we suggest that you
take into consideration:
•
•
•
•
•
•

The proximity to changing area and shelter (especially in colder
weather).
The pathway to and from your spa (this should be free of debris so
that dirt and leaves are not easily tracked into the spa).
The closeness to trees and shrubbery (remember that leaves and
birds could create extra work in keeping the spa clean).
A sheltered environment (less wind and weather exposure can result
in lowered operation and maintenance costs).
The overall enhancement of your environment. It is preferable not to
place the spa under an unguttered roof overhang since run-off water
will shorten the life expectancy of the spa cover.
For spas that are to rest on balconies, roofs or other platforms not
specifically tied into main structural support, consult a professional
Structural Engineer with experience in this type of application.

4.2
Indoor Location
For indoor installations many factors need to be considered before
installing a spa indoors:
•

Proper Foundation: Consult a Structural Engineer when
considering a foundation that will adequately support the spa
the entire time it is in place. Proper support is critical especially
if the spa is to rest on a second story or higher. For spas that are
to rest on balconies, roofs or other platforms not specifically tied
into the main structural support, you should consult a professional
Structural Engineer with experience in this type of application.

•

Proper Drainage: It is extremely important to have in place
measures to sufficiently handle excessive water spillage. Be
sure the flooring in which the spa rests on has adequate drainage
and can handle the entire contents of the spa. Be sure to make
provisions for ceilings and other structures that may be below the
spas installation. Areas around your spa can become wet or moist so
all flooring and subsequent furniture, walls and adjacent structures
should be able to withstand or resist water and moisture.

•

Proper Ventilation: Proper ventilation should be discussed with
an Engineer or authority competent enough to understand the
necessary provisions needed to vent moist or heated air and air
associated with chemical odors outdoors. When the spa is in use
considerable amounts of moisture will escape, potentially causing
mold and mildew over time which can damage certain surfaces and/
or surroundings.

10

J-200 Series
•

Sufficient Access: In the unlikely event that you should ever need
to access or gain entry to any portion of the spa for servicing, it is
highly recommended that you plan your indoor installation to provide
full access to the entire spa.

•

Warranty: Damage caused by not following these guidelines or any
improper installation not in accordance to local codes or authorities is
not covered under the spas warranty. Please consult your local state
or city building ordinances.

!

WARNING: In addition to maintenance of filters and water
chemistry, proper ventilation is recommended to reduce the
risk of contracting a waterborne illness (e.g. an infection,
bacteria or virus) and/or respiratory ailments that could be
present in the air or water. Consult a licensed architect or
building contractor to determine your specific needs if
installing your hot tub indoors.

11

J-200 Series
5.0

General Electrical Safety Instructions

Your new Jacuzzi® spa is equipped with a “state-of-the-art”
equipment system. It contains the most advanced safety
and self-protective equipment in the industry.
Nonetheless, this spa must be installed properly to insure
dependable usage. Please contact your dealer or local building
department should you have any questions regarding your installation.
Proper grounding is extremely important. Jacuzzi spas are equipped with
a current collector system. A pressure wire connector is provided on the
surface of the control box, located outside the equipment door (Figure B,
page 17) to permit connection of a bonding wire between this point and
any ground metal equipment, metal water pipe or conduit within
5 feet (1.5m) of the spa, or copper clad grounding rod buried within 5 feet
(1.5m) of the spa. Bonding wire must be at least No. 8 AWG (8.4 mm²)
solid copper wire. This is a most important safety assurance feature.
Before installing this spa, check with the local building department to
insure installation conforms to local building codes.
120/240 Volt Convertible Models
A spa connected to a 120 VAC electrical service must be located close
enough to a grounded, grounding-type electrical outlet so that the
included 10 foot (3m) power cord can be plugged directly into it. DO NOT
USE AN EXTENSION CORD as this could cause damage to the spa’s
equipment due to insufficient voltage. The power supplied to this spa
must be a dedicated circuit with no other appliances or lights sharing the
power provided by the circuit.

12

J-200 Series
6.0	Power Requirements
Jacuzzi® spas are designed to provide optimum performance and
flexibility of use when connected to the maximum electrical service listed
below. Minor circuit board modifications can be performed to allow your
new spa to accept an electrical service other than the factory operation
setting.
Note: Refer to pages 44-47 for circuit board configuration details or
contact your authorized Jacuzzi dealer.
All North American J-270 and J-280 Models (60 Hz)
Circuit Breaker (2-Pole):
Number of Wires:
Frequency:
Current Draw:

240V/40A*

240V/50A**

240V/60A***

40A*

50A**

60A***

3

3

3

60 Hz

60 Hz

60 Hz

26A

36A

45A

In 40A configuration, the heater will not operate while either jets
pump is running in high speed. Note: pump 2 runs only in high
speed.
** In 50A configuration, the heater will not operate while both jets
pumps are running in high speed. This is the factory setting.
Note: pump 2 runs only in high speed.
*** In 60A configuration the heater will operate while both jets pumps
are running in high speed.
*

All North American J-230 Models (60 Hz)
Circuit Breaker (2-Pole):
Number of Wires:
Frequency:
Current Draw:
*
**

240V/40A*

240V/50A**

40A*

50A**

3

3

60 Hz

60 Hz

26A

36A

In 40A configuration, the heater will not operate while the jets
pump is running in high speed.
In 50A configuration, the heater will operate while the jets pump is
running in high speed. This is the factory setting.

13

J-200 Series
All North American J-210 Convertible Models (60 Hz)
120V/15A†

240V/30A†

240V/40A‡

Circuit Breaker:

15A†, 1-Pole

30A†, 2-Pole

40A‡, 2-Pole

Number of Wires:

3 (15A GFCI
Cord US
Only*)

4 (Hard Wire
Only)

4 (Hard Wire
Only)

60 Hz

60 Hz

60 Hz

12A

21A

30A

Frequency:
Current Draw:

* All Canadian spas must be hard wired per CSA Canadian standards.
(page 8)
† In 15A/30A configuration, the heater will not operate while the jets
pump is running in high speed. The factory setting is 120V/15A.
‡ In 40A configuration, remove jumper JP1-2 on the board, to allow the
heater to operate when the jets pump is running in high speed.
CAUTION (For 4-wire 240 VAC Heater Operation): Move the
red wire on the main terminal strip (TB1) from position #1 to
position #3. Make certain wires are connected exactly as shown
in Figure-D (Page 18) before applying power. Failure to do so will
result in damage to the circuit board and/or related components
and void the manufacturer’s warranty.

Export J-270 and J-280 Models (50 Hz)
Circuit Breaker:
Number of Wires:
Frequency:
Current Draw:

230V/20A*

230V/30A**

230V/40A***

20A*

30A**

40A***

3

3

3

50 Hz

50 Hz

50 Hz

15A

23A

29A

In 20A configuration, the heater will not operate while either jets
pump is running in high speed. This is the factory setting. Note:
pump 2 runs only in high speed.
** In 30A configuration, the heater will operate while one jets pump is
running in high speed. Note: pump 2 runs only in high speed.
*** In 40A configuration the heater will operate while both jets pumps
are running in high speed.
*

14

J-200 Series
Export J-210 and J-230 Models (50 Hz)
Circuit Breaker:
Number of Wires:
Frequency:

230V/20A*

230V/30A**

20A*

30A**

3

3

50 Hz

50 Hz

Current Draw:
15A
21A
* In 20A configuration, the heater will not operate while the jets
pump is running in high speed. This is the factory setting
** In 30A configuration, the heater will operate while the jets pump is
running in high speed.

15

J-200 Series
7.0	Electrical Wiring Instructions
IMPORTANT NOTICE: The electrical wiring of this spa
must meet the requirements of the National Electrical
Code/USA (NEC) and any applicable state or local codes.
The electrical circuit must be installed by a qualified electrician and
approved by a local building/electrical inspection authority.
1. Convertible 120/240V Power Models:
•

•

2.

3.
4.
•
•
•
•
5.

6.
7.

16

! DANGER: To DECREASE the risk of shock,
product damage or electrical fire.
120V “Plug-in” Operation: This spa must operate on the supplied
120V GFCI cord at its original length or must be hard-wired for longer
runs. NEVER USE AN EXTENSION CORD FOR ANY REASON!
Convertible 120/240V heater Operation: The included 120V
GFCI cord must be discarded for 240V heater operation. This spa
must be hard wired. Supplying power to either configuration above
which is not in accordance with these instructions will void both the
independent testing agency listing and the manufacturer’s warranty.
Dedicated 230V-240V models must be permanently connected
(hard-wired) to the power supply. No plug-in connections or
extension cords are to be used in conjunction with the operation
of this spa. Supplying power to the spa which is not in accordance
with these instructions will void both the independent testing agency
listing and the manufacturer’s warranty.
The power supplied to this spa must be a dedicated circuit with no
other appliances or lights sharing the power provided by the circuit.
To determine the current, voltage and wire size required, refer to
section 6.0 “Power Requirements” (page 13).
Wire size must be appropriate per NEC/USA and/or local codes.
We recommend type THHN wire.
All wiring must be copper to ensure proper connections. Do not use
aluminum wire.
When using wire larger than #6 (10 mm²), add a junction box near
the spa and reduce to short lengths of #8 (8.4 mm²) wire to connect
to the spa.
The electrical supply for this product must include a suitably rated
switch or circuit breaker to open all ungrounded supply conductors
to comply with Section 422-20 of the National Electrical Code/USA,
ANSI/NFPA 70. The disconnecting means must be readily accessible
to the spa’s occupant but installed at least 5 feet (1.5m) from spa
water.
The electrical circuit supplied for the spa must include a suitable
ground fault circuit interrupter (GFCI) as required by NEC/USA Article
680-42.
To gain access to the spa’s power terminal block, remove the screws
securing the synthetic cabinet panel under the control panel (Figure A).

J-200 Series
Then remove the four control box door screws and door (Figure B).
8. Select the power supply inlet you want to use (Figure A). Feed power
cable to control box, then install it through the large opening provided
in the bottom side of the box.
9. Connect wires, color to color, on terminal blocks TB1 and TB3
(Figure C, page 18). TIGHTEN SECURELY! All wires must be
hooked up securely or damage could result.
10. Install control box door and screws and reinstall the cabinet side
panels.
Figure-A
Equipment Area

9

7
8

1
Flow

4
6
2
1.
2.
3.
4.
5.

5

3
Note: Pump Locations Vary by Model

Control Box
Power Supply Inlet(s)
2-Speed Pump #1
Heater
Pump Drain Plug

6.
7.
8.
9.

5

2

1-Speed Pump #2
Optional CD Ozonator (Purchased Separately)
Ozone Injector
Control Panel

Figure-B - Control Box

2
TB1

1. Terminal Block
2. Bonding Lug
3. Grounding Terminal

1

3

17

J-200 Series
WHT

TB1

RED

1

Figure-D

to Circuit
Board

3

TB1

WHT

RED
BLK

BLK

BLK

2

WHT
1

BLK

BLK

Power In

WHT

Power In

Figure-C

BLK

2
RED

RED

3

to Circuit
Board

GRN

GRN

North American Convertible
Models: 120/240 VAC, 3-Wire
Connection 60 Hz

Move Red
Wire Here

North American Convertible
Models: 120/240 VAC, 4-Wire
Connection 60 Hz

CAUTION (For 4-wire 240 VAC Heater Operation): Move the
red wire on the main terminal strip (TB1) from position #1 to
position #3. Make certain wires are connected exactly as shown
in Figure-D before applying power. Failure to do so will result in
damage to the circuit board and/or related components and void
the manufacturer’s warranty.
RED
1

Power In

BLK
2
Green

TB1

RED
RED

TB1

Figure-F
1

BLK
BLK

to Circuit
Board
TB3

North American 240V Models:
240 VAC, 3-Wire Connection 60 Hz

BLUE
BLUE
BROWN
BROWN

Power In

Figure-E

2
Green

to Circuit
Board
TB3

All Export Models: 230 VAC, 3-Wire
Connection 50 Hz

Congratulations! You are now all set to get your new spa ready to use.
Simply follow the step-by-step procedure in Section 8.0, before long,
you will be enjoying your first glorious experience in your Jacuzzi J-200
Series spa.

18

J-200 Series
8.0	Spa Fill Up Procedure
For best results, read each step in its entirety before proceeding with that
step.
1. Prepare The Spa For Filling
• Clear all debris from the spa. (Although the spa shell has been
polished at the factory, you may want to treat it with a specially
formulated spa cleaner.) Consult your authorized Jacuzzi dealer for
additional information prior to filling spa.
• Remove filter cover, then remove filter cartridge as outlined in section
12.1 (page 32).
2. Fill Spa
• Place the end of your garden hose into the empty filter bucket.
CAUTION: TO DECREASE BUILD UP ON COMPONENTS AND
MINIMIZE ACRYLIC DAMAGE.
Never fill with water from a water softener. If your water is extremely
“hard”, it is preferable to fill half-way with hard water and the rest of
the way with softened water. You may fill entirely with hard water if
you use a special water additive available from your Jacuzzi dealer.
•

!

WARNING: to decrease RISK OF infection or
disease.
Fill hot tub with clean tap water from garden hose, to reduce risk of
contracting a waterborne illness (e.g. an infection, bacteria or virus)
and/or respiratory ailments. Fill until water covers all jets but does not
touch the bottom of the lowest headrest. (DO NOT OVERFILL!)

3. Turn On Power
Turn on power to spa at the home’s circuit breaker to start boot
up sequence (sec. 10.0, page 25). The heater and filter pump will
automatically activate after several seconds. If the control panel LED
flashes water temperature and “COL” or “ICE” this is normal, refer to
page 39 for additional information.
4. Activate Jets Pumps
Turn on jets pump(s) to ensure proper mixing when
adding start-up chemicals in step 5.

1

2

5. Add Start-Up Chemicals
Add the spa water chemicals as recommended by your authorized
Jacuzzi dealer. See section 13.0 “Water Quality Maintenance” (page 37)
for general guidance.

19

J-200 Series

!

WARNING: Risk of poisoning or death.
Never leave chemicals opened and accessible to anyone.
Use chemicals according to the vendors instructions. Always
store chemicals in a safe and/or locked location. Keep away
from and out of reach of children.

6. Establish A Stable Sanitizer Reading
Establish a stable sanitizer reading between 3.0-4.0 ppm chlorine or 2.04.0 ppm bromine. To ensure healthy water conditions, always maintain
a constant sanitizer reading within the levels recommended by the
Association of Pool And Spa Professionals/USA printed on the inside
cover of this manual. If sanitizer levels cannot be stabilized, perform the
decontamination procedure steps 9-16 on page 21-23.
Note: The “decontamination procedure” steps 9-16 should also be used
after the spa has been “Winterized” (section 12.7 page 36) or has been
sitting without power for an extended period.
7. Set Spa To Heat
To warm spa water to a comfortable temperature,
follow these steps:
• The LED display on the control panel displays the
actual temperature of the spa water. Press either
the COOLER ( ) or WARMER ( ) button once
to display the “set” temperature for 5 seconds. If you want the water
to heat to a different temperature, simply press COOLER ( ) or
WARMER ( ) within 5 seconds. The set temperature increases or
decreases by one degree each time one of these buttons is pressed.
• The heater will turn off when the temperature corresponding to the
thermostat setting is achieved.
Important Heater Details:
• The maximum water temperature setting for your spa is 104°F
(40°C) and the minimum setting is 65°F (18°C).
• For North America spas connected to a 40 amp service, jets pump
#1 must be set to low speed and jets pump #2 must be turned off to
operate the heater.
• For Export spas connected to a 20 amp service, jets pump #1 must
be set to low speed and jets pump #2 must be turned off to operate
the heater.
• Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
• The heater operates until the water reaches the programmed “set
temperature”, then turns off. The heater will reactivate after the
water cools to approximately 1.5° below the set temperature.

20

J-200 Series
8. Place Cover On Spa
• Keeping the insulating cover in place anytime the spa is not in
use will reduce the time required for heating, thereby minimizing
operating costs.
• The time required for initial heat-up will vary depending on the
starting water temperature.

!

DANGER: Risk of PERSONAL injury.
Check water temperature carefully before entering hot tub!
Excessive water temperature can cause burns, welts and
body temperature to rise, hyperthermia (over-heating).

Decontamination Procedure (Steps 9-16)
Steps 9-16 below are only required when sanitizer levels are unstable
after performing steps 1-6 above. Disregard steps 9-16 below if sanitizer
levels remain stable at 3.0-4.0 ppm chlorine or 2.0-4.0 ppm bromine after
performing steps 1-6.
9. Add 2.5 ounces of sodium dichlor for every 100 gallons of water.
Refer to the table below for approximate water fill volume by model.

!

CAUTION: Risk of PERSONAL injury OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub for
any reason! These chemical may damage components within
your hot tub, burn or irritate your skin, create a rash, and void
the manufacturer warranty for your spa.

Water Fill Volume by Model
Spa Model

Approximate Fill Volume

Sodium Dichlor

J-280

539 US Gallons (2,041 Liters)

14.0 oz

J-270

530 US Gallons (2,006 Liters)

13.0 oz

J-230

430 US Gallons (1,628 Liters)

11.0 oz

J-210

298 US Gallons (1,128 Liters)

8.0 oz

21

J-200 Series
10. Leave spa cover open during this step to allow
excessive chemical vapors to exit spa,
protecting pillows and plastic knobs from
chemical attack. If spa is indoors, open doors
and windows for proper ventilation. Turn on all
jet pumps for one hour, then place the massage
selector knob in the center “combo” position
and open all air controls (Figure A is for all
models except the J-210). For the J-210 models
(Figure B) turn the Diverter Jet in the “combo”
position.
Note: You will need to press the jets pump button(s)
every 20 minutes since these functions have an
automatic 20 minute time-out function that turns
them off.

!

Massage Selector

Figure A

A
B

C
Figure B

Set all air controls to
their full open
counterclockwise position

WARNING: risk of PERSONAL INJURY!

•

•

To decrease the risk of injury, drowning or entrapment,
never leave your hot tub unattended for any reason while
the cover is open and accessible, especially to small
children and animals!
Precautions should be taken to minimize your exposure
to chemical vapors (that could cause lung, brain, or skin
damage).

11. Turn off power to the spa at the circuit breaker, then drain spa as
outlined in section 12.2 “Draining And Refilling” (page 35).
12. Fill spa until water covers all jets but does not touch the bottom of
the lowest headrest. DO NOT OVERFILL.
CAUTION: TO DECREASE BUILD UP ON COMPONENTS AND
MINIMIZE ACRYLIC DAMAGE.
Never fill with water from a water softener. If your water is extremely
“hard”, it is preferable to fill half-way with hard water and the rest of
the way with softened water. You may fill entirely with hard water if
you use a special water additive available from your Jacuzzi dealer.
13. Consult your authorized Jacuzzi dealer for chemical
recommendations, then add chemicals to spa water to achieve a
constant sanitizer reading within the levels recommended by the
Association of Pool And Spa Professionals/USA printed on the inside
cover of this manual.
14. Turn on all jet pumps when adding chemicals to ensure proper
mixing and leave your spa cover open until the sanitizer level falls
below 4.0 ppm to protect pillows and plastic knobs from chemical
attack.

22

J-200 Series

!

WARNING: RISK OF PERSONAL INJURY.
•

•

To decrease the risk of injury, entrapment or drowning,
never leave your hot tub unattended for any reason,
especially if while the cover is open and accessible to
small children and animals!
To decrease the risk of contracting a waterborne illness
(e.g. an infection, bacteria or virus) and/or respiratory
ailments, maintain water chemistry within 6 step
parameters. If you or other bathers experience such a
condition, discontinue use and seek immediate medical
attention

15. Establish a sanitizer reading between 3.0-4.0 ppm chlorine or
2.0-4.0 ppm bromine, then allow the spa to set undisturbed for 8
hours. Retest water after 8 hours to determine if sanitizer levels
are stable. If sanitizer levels are stable, your spa is ready for use.
To ensure healthy water conditions, always maintain a constant
sanitizer reading within the levels recommended by the Association
of Pool And Spa Professionals/USA printed on the inside cover of
this manual. If sanitizer levels are not stable at this time, it will be
necessary to repeat this procedure in its entirety (steps 1-15) until
stable sanitizer readings are achieved.
16. After adequate sanitizer levels are achieved, close all spa air controls
by rotating them clockwise to maximize heat retention when spa is
not in use.

23

J-200 Series
9.0

Control Functions

9.1
Control Panel
A. LED Display: Can
display current water
temperature (default display), water
temperature set point,
selected filtration/
heating mode, and
error messages.

C

D

1
2

A

E

B

F

G

B. Heat Indicator: Lit when heater is on.
C. Jets 1 Button: Turns jets pump #1 on and off. Press once for low
speed; press a second time for high speed; press a third time to turn
pump off.
D. Jets 2 Button: Turns high-speed jets pump #2 on and off. Press
once to turn pump #2 on; press a second time to turn pump #2 off.
E. Light Button Options:
• With standard incandescent light: Turns underwater light on and off.
• With optional LED lighting system: Turns underwater light and top
rim accent lights on in one of three random modes or one of seven
solid colors. Refer to section 10.4 (page 27) for details.
F.

Warmer (

G. Cooler (

) Button: Increases water temperature set point.
) Button: Decreases water temperature set point.

Operation Details
• Temperature Adjustment: 65 to 104°F (18 to 40°C). Factory default
setting is 100°F (38°C).
• Standard light system: Incandescent light runs for 1 hour, then
automatically shut off for increased bulb life.
• Optional LED light system: All LED lights run for 1 hour, then
automatically shuts off.
• Jets 1/Jets 2 Button Operation: Jets run for 20 minutes when
activated, then turn off automatically to conserve energy. Simply
press either jets button to continue operation for an additional 20
minutes.

24

J-200 Series
9.2

General Spa Features and Controls

11

8

5

11

3

2

2
4

4

3
7

10

7

7

3

9

4

6a

11

6b

2
1

J-280 model illustrated Jet locations and features will vary by model.

1.
2.
3.
4.
5.
6.
•
•

Control Panel
Headrest Pillows (4 ea.)
Air Controls (4 ea.)
Cup Holders (4 ea.)
Massage Selector (1 ea.)
Lighting System Options:
Standard Underwater light system
includes incandescent light (6a)
Optional LED lighting system
includes LED footwell light (6a) and
multiple LED accents lights (6b).

3

2

11

4

12
7. Suction Fittings and Filters
(Filters protect massage selectors
from debris entrapment/damage.
Filters require periodic cleaning.)
8. Waterfall with flow rate control
lever.
9. Heater Return/Gravity Drain
10. Filter lid with one underlying filter
cartridge.
11. Optional audio system speakers
(4 ea.)
12. Optional audio system AM/FM/CD
stereo deck.

Specifications Subject to Change Without Notice.

25

J-200 Series
10.0	Operating Instructions
The spa control system has automatic functions that operate upon
start-up and normal operation to protect the system. Upon power up, the
readout displays the following information:
Spas with
Circulation

Spas without
Circulation

1. Control panel displays current software
Pump Option Pump Option
release (3.56 or 5.56 depending on spa
model) then;
1.
2. Control panel displays “888” and all
indicator LEDs are lit, permitting visual
2.
inspection of all display segments and
indicator lights for proper operation.
3. After the initial start-up sequence
3.
ends, the actual water temperature is
displayed. If water temperature at this
time is less then the factory default temperature setting of 100°F
(38°C) and the spa is set to either standard filtration/heating mode
(Sections 11.1-11.2, page 28), the heater will turn on and run until the
water temperature rises to the factory setting, then turn off.
Note: It is common for the heater to turn on after the spa is first filled
because tap water is often very cold.
10.1	Setting Water Temperature
The spa’s thermostat provides optimum control of
water temperature. The temperature set point (set
temperature) can be adjusted from 65-104°F (18-40°C).
To raise the set temperature, press the WARMER ( )
button. To lower the set temperature, press the COOLER ( ) button.
Note: The first press of either WARMER ( ) or COOLER ( ) button
displays the set temperature.
10.2	Activate Jet Pumps
1
The control panel JETS 1 button activates jets pump 1.
The first press activates low speed, the second press
2
activates high speed, and the third press shuts jets pump
1 off. The JETS 2 button activates jets pump 2. The
first press activates high speed, the second press turns jets pump 2 off.
When manually activated, either pump will automatically turn off after 20
minutes.
10.3	Standard Light Operation
The light button activates the foot well light in the spa
when pressed. Pressing the button turns the foot well
light off. When manually activated, the foot well light will
automatically turn off after one hour.

26

J-200 Series
10.4	Optional Multi-Colored LED Light System Operation
The multi-colored LED spa light offers seven constant color
variations and three unique random modes for enhanced
spa enjoyment. Press the Light button once to activate the
first light mode Random Fade, then continue pressing the
button to either turn the light off or to select one of seven
constant colors, random solid color mode or strobe mode as illustrated
below.
RANDOM
FADE

OFF

NEAR
WHITE

OFF

LIGHT
BLUE

OFF

VIOLET

OFF

DARK
GREEN

OFF

LIME
GREEN

DARK
BLUE

Spa Light Sequence

OFF

STROBE

RANDOM
SOLID

RED

OFF

OFF

Light Operation Tips:
You must press the light button within 3 seconds of any “off” condition
or the light sequence will revert back to “Random Fade” mode, when
reactivated.
Anytime the spa light is manually activated, it will remain on for 1 hour
then automatically shut off.
10.5	Adjusting Individual Jet Flow
The water flow through individual jets in your spa can be
adjusted or turned off by rotating the outside jet ring. Many
jets also offer an adjustable center nozzle that allows
you to change the water discharge angle. Simply tilt the center nozzle in
these jets to the desired angle to customize your personal massage.
Note: Always keep at least 6 adjustable jets open at all times to ensure
proper filtration characteristics within spa.
C

10.6	Selecting Desired Massage Action
All models incorporate a massage selector (Diverter
Jet for J-210, Figure A) valve that allows you to
B
A
customize the massage and performance by
A
diverting water between various jet systems within
B
the spa. Simply turn valve to positions A, B or C to
divert water pressure to various jet groups.
C
Note: The valve is intended to operate in positions
Figure A
A (Combo), B, or C for optimum performance. It is
considered normal for sound levels within the valve to increase between
these positions due to the large amounts of water flowing through it. For
optimum filtration benefits, always leave this valve in position A when the
spa is covered and select positions B or C for maximum jet performance
during spa use.

27

J-200 Series
10.7	Air Controls
Certain jet systems have their own air control. Each control
introduces air into the water lines that supply that specific
jet group. Simply turn the air control of choice
counterclockwise to open or clockwise to close. To
minimize heat loss, all air controls should be closed when the spa is not
in use.

11.0	Automatic Filtration Cycles
The control system activates a programmable “standard” or “economy”
filtration cycle to remove debris from your spa. These cycles use the low
speed jets pump 1 and filter cartridge to quickly clear “skim” the water
of debris and minimize their “bathtub ring” affect while the spa is in use
or during a programmed filter cycle. Models equipped with the optional
24-hour circulation pump offer the added benefit of 24-hour filtration for
pennies a day!
Apart from their filtration benefit, each filtration mode also effects the
operation of the spa heater. Refer to sections 11.1 and 11.2 for details.
11.1	Standard Filtration/Heating Modes For Models Without
Circulation Pump Option (All Models)
Standard filtration/heating modes (F1-F3) are typically selected by
customers in cold climates where heat up times are extended due
to lower ambient temperatures. In either of these modes, the water
temperature is regulated by the set temperature, low-speed jets pump
1 and heater which turns on as needed. After the programmed set
temperature is reached, the heater and low speed pump turn off, only to
turn back on during a heat call or during the next programmed filtration/
heating cycle.
11.2	Standard Filtration/Heating Modes For Models With
Circulation Pump Option (J-230, J-270 and J-280 Only)
Standard filtration/heating modes (F0-F3) are typically selected by
customers in cold climates where heat up times are extended due
to lower ambient temperatures. In either of these modes, the water
temperature is regulated by the set temperature, 24-hour circulation
pump and heater which turns on as needed. After the programmed set
temperature is reached, the heater turns off and the circulation pump
continues to operate 24-hours to filter and clean your spa.

28

J-200 Series
11.3	Economy Filtration/Heating Modes (All Models)
Economy filtration/heating modes (F4-F6) are typically selected by
customers in warm climates where heat up times are minimized due
to higher ambient temperatures. In either of these modes, the water
temperature is regulated by the set temperature, low-speed pump or
optional circulation pump, and heater only while a programmed filtration/
heating cycle is running.
Note: These modes can be used to conserve energy while on vacation
or out of town for several weeks since heater operation is minimized.
During such times, you can also minimize the spa set temperature to
maximize energy savings!
11.4	Lock Modes - L1-L2 (All Models)
These modes are designed for use during spa service or to prevent
unauthorized use.
11.5	Selecting The Filtration/Heating Mode
Press and hold both control panel WARMER ( ) and COOLER ( )
buttons at the same time, then release. Then press either WARMER
( ) or COOLER ( ) button to select either filtration/heating mode or
lock mode as outlined below.
11.6

Filtration Modes for Spas Without Circulation Pump Option
(All Models)
If your spa is equipped with the circulation pump option, disregard this
section and refer to page 30 for filter cycle programming details.
Standard Filtration/Heating Modes (F1-F3)
(Heater automatically turns on during any heat call while in any Standard
mode).
F1 4 hours of filtration/heating per day (one 2-hour cycle
every 12 hours).
F2 6 hours of filtration/heating per day (one 2-hour cycle
every 8 hours).
F3 8 hours of filtration/heating per day (one 2-hour cycle
every 6 hours)
Economy Filtration/Heating Modes (F4-F6)
(Heater can only turn on during an active filter cycle while in any
economy mode).
F4 4 hours of filtration/heating per day (one 2-hour cycle
every 12 hours).
F5 6 hours of filtration/heating per day (one 2-hour cycle
every 8 hours).
F6 8 hours of filtration/heating per day (one 2-hour cycle
every 6 hours)

29

J-200 Series
Lock Modes (L1-L2)
L1 Lock Out (disables all spa functions to permit filter
cleaning)
L2 Lock Mode (disables the jets and light buttons to
prevent unauthorized use of spa). Filtration/heating
cycle will continue to operate as programmed in
this mode. The temperature display flashes when this function is
enabled. Example: the “F3” filtration/heating cycle was enabled
prior to choosing lock mode. The spa continues to perform the
“F3” cycle until lock mode is canceled, allowing another cycle to be
selected.
To set a time for the first filtration/heating cycle, simply turn power on to
the spa two minutes prior to the desired time. Example: If you desire your
first filtration/heating cycle to begin at 10:00 AM turn off power to the spa
and turn it back on again at 9:58 AM.
Note: Start time is approximate and may vary slightly from day to day.
11.7

Filtration Modes for Spas With Circulation Pump Option
(J-230, J‑270 and J-280 Only)
If your spa is not equipped with the circulation pump option, disregard
this section and refer to page 29 for filter cycle programming details.
Standard Filtration/Heating Modes (F0-F3)
(Heater automatically turns on during any heat call while in any Standard
mode).
F0 5 minutes of filtration per day (one 5 minute “Blow-Out”
cycle every 24 hours to purge all plumbing lines)
F1 1 hour of filtration per day (one 30-minute cycle every
twelve hours); this is the factory default setting.
F2 1.5 hours of filtration per day (one 30-minute cycle
every eight hours).
F3 2 hours of filtration per day (one 30-minute cycle every
six hours).
Economy Filtration/Heating Modes (F4-F6)
(Heater can only turn on during an active filter cycle while in any
economy mode).
F4 1 hour of filtration/heating per day (one 30-minute
cycle every twelve hours).
F5 1.5 hours of filtration/heating per day (one 30-minute
cycle every eight hours).
F6 2 hours of filtration/heating per day (one 30-minute
cycle every six hours).

30

J-200 Series
Lock Modes (L1-L2)
L1 Lock Out (disables all spa functions to permit filter
cleaning).
L2 Lock Mode (disables the jets and light buttons to
prevent unauthorized use of spa). Filtration/heating
cycle will continue to operate as programmed in
this mode. The temperature display flashes when this function is
enable. Example: the “F3” filtration/heating cycle was enabled prior
to choosing lock mode. The spa continues to perform the “F3” cycle
until lock mode is canceled, allowing another cycle to be selected.
Filter Cycle Setup Example
To set a time for the first filtration/heating cycle, simply turn power on to
the spa two minutes prior to the desired time. Example: If you desire your
first filtration/heating cycle to begin at 10:00 AM turn off power to the spa
and turn it back on again at 9:58 AM.
Note: Start time is approximate and may vary slightly from day to day.

31

J-200 Series
12.0	Spa Maintenance
Proper and regular maintenance of your spa will help it retain its beauty
and performance. Your authorized Jacuzzi dealer can supply you with
all the information, supplies, and accessory products you will need to
accomplish this.
!

•
•
•
•

•

•

DANGER: Risk of Severe Injury or Drowning by
entrapment!
Keep hair, loose articles of clothing or hanging jewelry away from
suction fittings, rotating jets or other moving components to avoid
entrapment that could lead to drowning or severe injury.
Never use the spa unless all suction guards, filter, filter lid, or skimmer
assembly are installed to prevent body and/or hair entrapment.
Never operate or use the spa if the filter, filter lid, or skimmer assembly
are broken or any part of the skimmer assembly is missing. Please
contact your dealer or nearest service center for service.
The suction fittings and suction covers in this spa are sized to match
the specific water flow created by the pump(s). If it is necessary to
replace the suction fittings, suction covers or pump(s), be sure that the
flow rates are compatible and are in compliance with the VGB Safety
Act page 2.
Never replace a suction fitting or suction cover with one rated less
than the flow rate marked on the original suction fitting. Using improper
suction fittings or suction covers can create a body or hair suction
entrapment hazard that may lead to drowning or severe injury.
Owners must alert all spa users to the potential risk of Hair, Limb,
Body, Evisceration (disembowelment), and Mechanical Entrapment,
page 6.

12.1
Cleaning The Filters
TO DECREASE DROWNING OR ENTRAPMENT, ALWAYS TURN
POWER TO SPA OFF BEFORE CLEANING THE FILTER CARTRIDGE!
J-210 Models:
These model spas are equipped with a skimmer basket and filter
cartridge located in the skimmer/filter well. Filtering is accomplished
when jets pump #1 turns on in low speed initiating water flow through
the skimmer basket and polyester mesh filter cartridge. As this happens,
suspended particles become trapped on the filter’s surface.
To Clean Filter:
1. Turn off power to the spa at the home’s breaker panel or select the L1
“Lock Out” mode (page 29) to disable all spa functions.
2. Remove the filter strainer lid assembly.
3. Remove the filter cartridge by rotating it counterclockwise to unthread it
from the filter wall fitting, then lift it straight up to remove from filter well.
4. Using a garden hose with a high-pressure nozzle, rinse debris from
the filter pleats beginning at the top and working your way downward.
Continue, one section at a time, until you have rinsed all of the filter’s
pleats.

32

J-200 Series
To ensure optimum performance, clean and reuse the skimmer bag and
filter cartridge once a month or as necessary, depending on use.
J-210 models include filters on their footwell suction covers
(shown right) that prevent debris from entering the pump and
the massage selector(s), when operating. These filters must
remain in place to protect these components from debris
entrapment/damage. They should be cleaned every 2 months,
or when weak pump performance is observed.
J-230, J-270 and J-280 Models:
These model spas are equipped with a skimmer bag and one high
performance pleated filter cartridge located under the filter cover as
illustrated below. Debris are filtered by the optional circulation pump
(when equipped) drawing water through the skimmer bag and filter
cartridge 24-hours a day, or by jets pump 1 when running a programmed
filter cycle or when manually activated by spa use. Combined, both
filters provide unsurpassed water quality by trapping surface oils and
suspended particles. The filter cartridge should be cleared once a month,
or as needed for optimum performance.
J-230, J-270 and J-280 Models:
Refer to steps A-J below for complete filter cleaning/replacement
instructions.
A

DANGER: TURN POWER TO SPA OFF! TO DECREASE
RISK OF DEATH, DROWNING, OR ENTRAPMENT,
NEVER OPERATE SPA WHEN FILTER IS NOT PROPERLY
INSTALLED OR IF SKIMMER ASSEMBLY IS DAMAGED OR
ALTERED!

B

Lift upward on filter
skimmer cover handles
to remove it from
mating retainer clips.

(Inside Spa View)

(Filter Cover Back View)

(Inside Spa
View)

C

Remove skimmer bag
from clips, then clean
out debris.

D

Rotate filter
cartridge handle
counterclockwise to
unthread filter cartridge
from mating wall fitting.

33

J-200 Series

C

ar
tr

id
ge

Trapped
Air
Bubbles

E

Lift unthreaded filter
cartridge from skimmer
well.

F

Rinse debris from filter
cartridge pleats using
a garden hose and
high-pressure nozzle.
Start at the top and
work downward to the
handle. Repeat until all
pleats are clean

G Submerge filter cartridge
in spa. Tilt threaded
end upward to remove
trapped air bubbles,
then keep cartridge
submerged to prevent
air entrapment during
installation (step H).

(Inside Spa View)
(Inside Spa View)

(Filter Cover Back View)

H

Install filter cartridge
back onto wall
fitting by rotating
the cartridge handle
clockwise. DO NOT
OVERTIGHTEN!

I

Install clean skimmer
bag back onto the filter
cover clips as shown.

J

Install filter cover by
sliding it down into
position over mating
spa retainer clips. Turn
spa power back on
after skimmer cover is
installed.

Periodically, the filter cartridge will need a more thorough cleaning to
remove imbedded oils and minerals. For this, we suggest cleaning as
illustrated in step “F”, followed by soaking the filter overnight in a plastic
container filled with a solution of water and specially formulated filter
cleanser available from your authorized Jacuzzi dealer. The average life
expectancy of each filter is approximately two years with proper care and
water quality maintenance. Replacement cartridges may be purchased
from your authorized Jacuzzi dealer.

34

J-200 Series
12.2
Draining and Refilling
About every 3 months, you will want to replace the spa’s water. The
frequency depends on a number of variables including the amount of
use, attention paid to water quality maintenance, etc. You will know it is
time for a change when you cannot control sudsing and/or you can no
longer get the normal feel or sparkle to the water even though the key
water balance measurements are all within the proper parameters.
CAUTION! READ THIS BEFORE DRAINING: To prevent damage
to the spa’s components, turn off power to the spa at the circuit
breaker before draining it. Do not turn the power back on until
your spa has been refilled.
CAUTION: There are certain precautions to keep in mind when
draining your spa. If it is extremely cold, and the spa is outdoors,
freezing could occur in the lines or the equipment, see “WINTERIZING” (page 36). On the other hand, if it is hot outdoors, do not leave
the spa’s surface exposed to direct sunlight.
To drain your spa, perform the following steps:
Turn off power to spa at breaker.
1. Locate and remove the synthetic cabinet
door screws and door. The door is located
directly below the control panel.
2. Cut Zip Tie(s) and pull drain hose from
Figure - A
equipment area (Figure-A).
3. Hold drain hose above water line, then
unthread drain cap (1) from hose using a
counterclockwise rotation. Place drain hose
on ground, turn valve (2) counterclockwise
to start drain, making sure to direct water
away from spa (Figure B).
4. After spa is drained, turn valve clockwise to
Figure - B
close and reinstall drain cap on drain hose
fitting until finger tight! DO NOT OVERTIGHTEN!
5. Coil drain hose up and place back inside the spa equipment bay (Fig. A).
6. Reinstall synthetic cabinet door and screws, then refer to the “Spa
Fill Up Procedure” (page 19).
12.3	Pillow Care
Remove and clean each headrest by gently grasping both ends in each
hand and pulling upward to release each pillow “snap.” To reinstall,
simply “snap” each pillow back into place. Clean as needed with soapy
water using a cloth or soft-bristle brush. To maintain water resistance and
luster, apply a quality vinyl conditioner once a month. Always remove
the pillows when adding chemical shock treatment to the spa water. The
headrests can be returned to the spa when the sanitizer reading drops
below 4 ppm.

35

J-200 Series
12.4
Cleaning The Spa Interior
To preserve the sheen of your spa’s surface, it is crucial that you avoid
using abrasive cleaners or cleaners which have adverse chemical effect
on the surface. If you are not certain as to the suitability of a particular
cleanser, consult your authorized Jacuzzi dealer. Regardless of the
cleanser used, use extreme care to assure that no soap residue is left on
the surface. This could cause severe sudsing when the spa is refilled.
12.5	Maintaining the Cover
Using the Jacuzzi insulating spa cover anytime the spa is not in use will
significantly reduce your operating costs, heat-up time and maintenance
requirements. To prolong the life of the cover, handle it with care and
clean it regularly using mild soap and water. Periodic treatments with a
special conditioner developed for Jacuzzi spa covers will help protect
against deterioration caused by UV rays from the sun.
Never allow anyone to stand or sit on the cover, and avoid dragging it
across rough surfaces.
12.6
Maintaining The Synthetic Cabinet
Your new spa’s synthetic cabinet requires little or no maintenance of
any kind. To clean, simply wipe cabinet with a clean towel and mild soap
solution.
CAUTION: Never spray cabinet with a garden hose for any
reason since this action may induce an electrical short in the
spa’s electrical equipment.
12.7	Winterizing
Your Jacuzzi spa is designed to automatically protect itself against
freezing when operating properly. During periods of severe freezing
temperatures, you should check periodically to be certain that the
electrical supply to the spa has not been interrupted. In extreme, bitter
cold weather less than -20°F (-29°C), choose the F3 “Standard” filtration/
heating mode to prevent freezing (pages 29-30). If you do not intend to
use your spa, or if there is a prolonged power outage during periods of
severe freezing temperatures, it is important that all water be removed
from the spa and equipment to protect against damage from freezing.
For expert winterization of your spa, contact your authorized
Jacuzzi dealer. In emergency situations, damage can be minimized by
taking the following steps:

36

J-200 Series
CAUTION: Turn off power to hot tub!
Follow the directions on page 35 for draining the spa.
1. As the water level drops below the seats, use whatever means
necessary to get the water out of the recessed seating areas and
into the foot well.
2. When the water level ceases to drop, use whatever means available
to remove any remaining water from the foot well.
3. Turn off power to the spa.
4. Remove the synthetic cabinet panel under the control panel and
locate the drain plugs on the front of the pump(s), (Figure A, page
17). Remove plugs to allow water to drain out of pumps and heater.
Note: Approximately one to two gallons will be released during this
procedure. Use a wet/dry vacuum or other means to keep this from
flooding the equipment compartment. Replace the drain plugs.
5. Re-install synthetic cabinet side panel and cover spa so that no
casual moisture can enter into it.
Consult your authorized Jacuzzi dealer if you have any questions
regarding winter use or winterizing.
12.8	Restarting Your Spa in Cold Weather
If you want to start up your spa after it has sat empty for a time in
freezing temperatures, be aware that the water remaining in certain
sections of the piping may still be frozen. This situation will block water
flow preventing the spa from operating properly and possibly damaging
the equipment. We recommend you consult your authorized Jacuzzi
dealer for guidance before attempting to re-start your spa under these
conditions.

13.0	Water Quality Maintenance
To decrease the risk of contracting a waterborne illness (e.g. an infection,
bacteria or virus) and/or respiratory ailments, maintain water quality
within specified limits. This will enhance your enjoyment and prolong
the life of the hot tub’s equipment. Doing so requires regular attention
because the water chemistry involved is a balance of several factors.
Procrastination in regard to water maintenance will result in poor and
potentially unhealthful conditions for soaking and even damage to your
hot tub investment. For specific guidance on maintaining water quality,
consult your Authorized Jacuzzi dealer who can recommend appropriate
chemical products for sanitizing and maintaining your hot tub.

37

J-200 Series

!

WARNING: Failure to maintain water quality
can result in:
• Increase risk of contracting a waterborne illness (e.g. an
infection bacteria or virus) and/or respiratory ailments.
• Damage the equipment, components and spa shell, which
are not covered under the hot tub’s warranty.

CAUTION: Never store hot tub chemicals inside the hot tub’s equipment bay. The equipment bay may reach elevated temperatures,
this is where high voltage electronic devices are located. This area
is not intended for storage of any kind.
13.1
pH Control
pH is a measure of relative acidity or alkalinity of water and is measured
on a scale of 0 to 14. The midpoint of 7 is said to be neutral, above which
is alkaline and below which is acidic. In spa water, it is very important
to maintain a slightly alkaline condition of 7.4 to 7.6. Problems become
proportionately severe the further outside of this range the water gets.
A low pH will be corrosive to metals in the spa equipment. A high pH will
cause minerals to deposit on the interior surface (scaling).
In addition, the ability of the sanitation agents to keep the spa clean is
severely affected as the pH moves beyond the ideal range. That is why
almost all spa water test kits contain a measure for pH as well as the
sanitizer.
13.2	Sanitizing
To destroy bacteria and organic compounds in the spa water, a sanitizer
must be used regularly. Chlorine and bromine are the two most popular
sanitizers used to date. Many other additives are available for your spa.
Some are necessary to compensate for out-of-balance water, some aid
in cosmetic water treatment and others simply alter the feel or smell of
the water. Your authorized Jacuzzi dealer can advise you on the use
of these additives. When adding spa shock (chlorine or non-chlorine)
or pH balancing chemicals activate the jets pump(s) and leave the spa
cover open for a minimum of 20 minutes. By doing this you will allow
excessive chemical vapors to exit the spa, protecting pillows and plastic
knobs from chemical attack.

38

J-200 Series

!

WARNING: Risk of PERSONAL injury, drowning

OR entrapment!
Never leave your hot tub unattended for any reason while the
cover is open and accessible, especially to small children and
animals!

CAUTION: Risk of PERSONAL injury OR SPA DAMAGE!
Never add chlorine tablets (trichlor) or acid to your hot tub for
any reason! These chemical may damage components within
your hot tub, burn or irritate your skin, create a rash and void
the manufacturer warranty for your spa.
13.3	Optional CD Ozone Water Maintenance System
If you have elected to have your spa equipped with the optional Jacuzzi
CD ozone water purification system you will find that your water stays
fresh and clear with significantly less chemical sanitizer usage. You will
also probably be able to go longer between complete spa drainings.

14.0	Error Conditions/Error Messages
Your spa has a self-diagnostic control system. The system will
automatically display the following if a problem is detected.
14.1	Summer Logic (Spas With Circulation Pump
Option)
When the actual spa water temperature reaches up to
2°F (1°C) above the set temperature, the spa goes into
“summer logic.” The 24-hour circulation pump will turn off
automatically to avoid adding additional heat to the water, eventually
creating an overheat condition. This setting is not user-programmable.
Note: The summer logic does not take effect until the spa water
temperature reaches 95°F (35°C). This condition is more likely in
excessively hot weather. Remember, the spa’s ability to cool is directly
affected by the ambient temperature. An excessively hot ambient
temperature may prevent the spa from cooling down because it’s
fully insulated construction is designed to retain heat and to minimize
operating costs.
14.2	Panel Displays COL
Cool Condition - Temperature has dropped 20°F (11°C)
below the current set temperature. Jets pump 1, (or
optional circulation pump) and the heater have been activated to bring
the temperature to within 15°F (8°C) of the set temperature. No
corrective action is required!
Note: This condition is common during first time fill ups or during refills
since tap water is often very cold.

39

J-200 Series
14.3	Panel Displays ICE
Freeze Protection - A potential freeze condition has been
detected. No action is required. Jets pump (or optional
circulation pump) and heater will operate to circulate and warm water
through the plumbing until spa is out of DANGER. See “Winterizing”
(page 36).
14.4	Panel Displays SN1
Open sensor (heater is disabled) or shorted sensor (spa is
deactivated). The high-limit temperature sensor is not
functioning. Contact your authorized Jacuzzi dealer or qualified service
technician.
14.5	Panel Displays SN2
Open or shorted sensor (heater disabled). The temperature
sensor is not functioning. Contact your authorized Jacuzzi
dealer or qualified service technician.
14.6	Panel Flashes FL1 or FL2 (Spas Without
Circulation Pump Option)
A flashing “FL1” display means the pressure switch is not
closed when the jets pump 1 is activated. Proper water
flow is inhibited or the pressure switch has malfunctioned. A flashing
“FL2” display means the pressure switch is malfunctioning closed. In
either case, the heater is deactivated. To correct condition, perform to the
following:
1. Verify water level is one inch below lowest pillow. Add water if
necessary.
2. Check for clogged or dirty filter cartridge (sec. 12.1, page 32).
3. Purge “air lock” from jets pump 1 by loosening the upper pump head
drain screw (Figure A, page 17) for a few seconds to release trapped
air, then retighten drain screw. FINGER TIGHT ONLY!
4. If problem persists, contact your authorized Jacuzzi dealer.
14.7	Panel Flashes FL1 or FL2 (Spas With Circulation Pump
Option)
A flashing “FL1” display means the flow switch is
malfunctioning open, the filter cartridge is excessively
dirty or an “air lock” condition has occurred at the
circulation pump intake. A flashing “FL2” display means
the flow switch is malfunctioning closed. In either case,
the spa heater will deactivate and jets pump #1 may also deactivate. To
correct condition perform the following:

40

J-200 Series
1. Verify water level is 1" below lowest pillow. Add water if necessary.
2. Check for clogged or dirty filter cartridge (sec. 12.1, page 32).
3. Purge “air lock” from circulation pump intake by removing filter
cartridge. Hold your garden hose over the filter cartridge wall fitting
while using a rag as a seal around hose end. Ask a helper to turn
on water for 30 seconds, then turn off. Reinstall filter cartridge and
check spa (sec. 12.1, page 32).
4. If the circulation pump is not running, turn power off at the main
breaker, then turn power back on. This will reset the circulation pump
priming cycle. Once the pump is primed, the error should clear.
5. If problem persists, contact your authorized Jacuzzi dealer.
14.8	Panel Displays OH
!

WARNING: Risk of Hyperthermia (over-heating)
Causing Severe Injury, burns, or welts.

Water temperature is above acceptable limits. DO NOT
ENTER SPA! Water temperature has reached 112˚F
(44˚C) and the low speed jets pump 1 and optional
circulation pump (when equipped) has activated to circulate water
through heater. Contact your authorized Jacuzzi dealer or qualified
service technician.
14.9	Panel Displays (- - -)
!

WARNING: Risk of Hyperthermia (over-heating)
Causing Severe Injury, burns, or welts.

Water temperature is above acceptable limits. DO NOT
ENTER SPA! The safety “Watchdog” software has been
triggered and the spa is deactivated. A problem has been
detected which could cause damage to the spa or its
components. Contact your authorized Jacuzzi dealer or qualified service
technician.

41

J-200 Series
15.0	Troubleshooting Procedures
In the event your Jacuzzi® spa is not working the way it should, please
first review all the installation and operating instructions in this manual
and check the message on the panel display. If you are still not satisfied
it is working properly, please follow the appropriate troubleshooting
instructions below.
Note: If any of the supply cords to the accessories are damaged,
they must be replaced by authorized service personnel. Contact your
authorized Jacuzzi dealer or qualified service technician.
15.1	None of the Components Operate (e.g. Pump, Light)
Check the following:
1. Is there power to the spa?
2. Is the household circuit breaker tripped?
3. Contact your authorized Jacuzzi dealer or qualified service
technician.
15.2	Pump Does Not Operate But Light Does
Press the JETS 1 button:
1. If no water movement is detected, make sure power is going to
the spa and check the water level. If it does not solve the problem,
contact your authorized Jacuzzi dealer or qualified service
technician.
2. The main jets pump 1 operates but no water flows to jets. Check the
following:
• Jets may all be closed in spa. Verify all jets are in the open “on”
position (sec. 10.5, page 27).
• Pump may not be properly primed. This can happen after the spa is
drained and refilled. Press the JETS 1 button on the control panel
several times, never leaving the motor running for more than 5 to 10
seconds at a time. Turn power off and let the air out of spa plumbing
system by removing the filter cartridge (sec. 12.1, page 32). Make
certain you reinstall the filter cartridge before turning on spa power
and restarting the jets pump 1.
15.3	Poor Jet Action
1. Make sure jets are in the full open “on” position (page 27).
2. Press the JETS 1 button to make certain pump #1 is on.
3. Open all air controls to their full on position (counterclockwise).
4. Check for dirty filter. Clean, if necessary (section 12.1, page 32).
15.4	Water is Too Hot
Reduce thermostat setting.

42

J-200 Series
15.5	No Heat
1. Check thermostat setting.
2. Keep the spa cover in place while heating.
3. Check the settings to see if your spa is in economy filtration/heating
mode (page 28).
Should checking the above steps fail to correct the problem, please call
your dealer so that they may arrange service. We build the best spas in
the industry. Nonetheless, we are always striving to improve the quality
and features of our products.
Your input as a Jacuzzi spa owner is a cherished part of this process. If
you have any comments or suggestions, or if you wish to be informed on
any new products for your spa, please write to us.
CONGRATULATIONS on your good taste and welcome to the happiest
and most relaxed family in the world!

43

44

HI

HI

C

Not used on J-230

PUMP 2

PUMP 1

LO

* Shown
with Optional
Circulation
Pump

CIRC.
PUMP

O3

BLK

WHT

RED

BLK

WHT

BLK

WHT

BLK

WHT

WHT

BLK

WHT

OZONATOR (OPTIONAL)

OR

BLK

GRN

1

K6

K5

K4

K3

K2

K1

2

RED

J7
7

J8
6

Optional
Stereo

BLK

K7

K8

BLK

J10
4

J3

7
5
3
1

JP1

8
6
4
2

J2

RED

J9
2

J1

Heater
5.5 kW
240 VAC

This device complies with Part 15 of the
FCC rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful
interference.
2. This device must accept any inteference
received including interference that may
cause undesired operation.

FLOW SWITCH

HI - LIMIT / FREEZE SENSOR

TEMPERATURE SENSOR

Logic Jumper Settings (Factory Defaults Shown)
JP1 1-2 ON = 40A Logic
JP1 1-2 OFF = 50A Logic (Factory Default Setting)
JP1 3-4 ON = 2 Pump Operation (Not used on J-230)
JP1 3-4 OFF = 1 Pump Operation
JP1 5-6 ON = 60A Logic (Remove JP1 1-2 Jumper)
(Not used on J-230)
JP1 5-6 OFF = Leave of for 40A or 50A Logic
JP1 7-8 ON = °C Temperature Display
JP1 7-8 OFF = °F Temperature Display

Standard 240 VAC, 3-Wire Connection (60Hz, 1-Phase Service)
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST
BE APPROPRIATE PER NEC AND/OR LOCAL CODES

Power Supply

F1

J4

TRANSFORMER
240 VAC

F1
30A, 250V
SC-30

BLK
J5

RED BLK

TB1

RED
J6

J19

J18

J17

J16

J15

J14

J13

J11

J12

J21

J20

Control Panel

16.0

Standard
Footwell
Light

Optional
LED Lighting
System DCU

J-200 Series
Circuit Board Diagrams

16.1	North American J-230, J-270 and J-280 Models
This wiring diagram is used for all J-230, J-270 and J-280 240V
60 Hz North American spa models With or Without the Circulation Pump
Option.

J-200 Series
16.2	North American J-210 Convertible Models
This wiring diagram is used for all J-210 120/240V 60 Hz North American
convertible spa models.

J1 Logic Jumper Settings (Factory Defaults Shown)
JP1 1-2 ON = 30A Logic (4-wire 120/240 VAC operation only)
JP1 1-2 OFF = 40A Logic (4-wire 120/240 VAC operation only)
JP1 7-8 ON = °C Temperature Display
JP1 7-8 OFF = °F Temperature Display
J20

J21

8
6
4
2

Spa Light

Control
Panel

J1
7
5
3
1

Temperature Sensor
J2
Hi-limit/Freeze Sensor

BLK J12
Optional
Ozonator

O3

J3

J14

Pressure Switch

BLK J16

WHT

Transformer
120 VAC
F1

J11

WHT

J15

K5

J6

J17

TB1
3 BLK
BLK
2
WHT
1

WHT

J7

J8

RED BLK
RED

Heater OUT
J9

J10

RED BLK

This device complies with Part 15 of the
FCC rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful
interference.
2. This device must accept any inteference
received including interference that may
cause undesired operation.

THERM
SWITCH

Heater
1.0 kW @ 120 VAC (3-wire connection)
4.0 kW @ 240 VAC (4-wire connection)

GRN

BLK

K8

Heater IN

WHT

Main Pump
BLK
WHT
LO
HI

GROUND

Plug-in
GFCI
Cord (US
Models
Only) OR
Hard
Wire

F1
20A
250V
SC-20

K7

J5

J13

Standard 3-Wire 120 VAC Connection (60 Hz, 1 Phase, 15A Service)
Use copper conductors ONLY. Wire size must be appropriate per NEC and/or local codes.

RED*

WARNING, ELECTRICAL SHOCK HAZARD EXISTS! Always remove power to spa before wiring
and/or configuring the circuit board

GROUND
GRN

RED*

TB1
3
BLK
WHT

2
1

1. Remove and discard the factory installed GFCI Cord.
2. Move RED* wire from TB1 position #1 to TB1 position #3 as shown below.

Move Wi

re

Hard
Wire
Only

Optional 4-Wire 240/120 VAC Convertible Heater Connection
To circuit board

BLK

3. Permanently connect to the power supply. Use copper conductors ONLY.
Wire size must be appropriate per NEC and/or local codes.
4. If hot tub is to be operated on 30A service, make sure the jumper provided

WHT
RED*

at location JP1 #1&2 on the circuit board is installed. If hot tub is to be
operated on 40A service, remove the jumper JP1 #1&2 on the circuit board.

45

46

HI

HI

Not used on J-230

PUMP 2

PUMP 1

LO

CIRC.
* Shown PUMP
with Optional
C
Circulation
Pump

O3

OZONATOR (OPTIONAL)

SPA LIGHT

BLK

BRN

BLU

BLK

BRN

BLU

BRN

BLU

BRN

BLU

WHT

GRN

1

TB1

BLU
J6

J19

J18

J17

J16

J15

J14

J13

J12

J11

J21

J20

2

BLU

J7
7

J8
6
BRN

K7

K8

Optional Stereo And Power
Supply on J-335, J-345
Models Only.

BRN

J10
4

J3

7
5
3
1

JP1
8
6
4
2

J2

BLU

J9
2

J1

Heater
2.7 kW @
230 VAC

PRESSURE SWITCH

HI - LIMIT / FREEZE SENSOR

TEMPERATURE SENSOR

Logic Jumper Settings (Factory Defaults Shown)
JP1 1-2 ON = 20A Logic (Factory Default Setting)
JP1 1-2 OFF = 30A Logic
JP1 3-4 ON = 2 Pump Operation (Not used on J-230)
JP1 3-4 OFF = 1 Pump Operation
JP1 5-6 ON = 40A Logic (Remove JP1 1-2 Jumper)
(Not used on J-230)
JP1 5-6 OFF = Leave of for 20A or 30A Logic
JP1 7-8 ON = Celsius Temperature Display
JP1 7-8 OFF = Fahrenheit Temperature Display

230 VAC 3-Wire Connection (50Hz, 1-Phase Service)
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST BE
APPROPRIATE PER NEC AND/OR LOCAL CODES

Power Supply

F1

J4

TRANSFORMER
240 VAC

F1
20A, 250V
SC-20

BRN
J5

BLU BRN

K6

K5

K4

K3

K2

K1

Control Panel

J-200 Series

16.3	Export 50 Hz J-230, J-270 and J-280 Models
This wiring diagram is used for all J-230, J-270 and J-280 230V 50 Hz
Export spa models With or Without the Circulation Pump Option.

J-200 Series
16.4	Export 50 Hz J-210 Models
This wiring diagram is used for all J-210 230V 50 Hz Export spa models.

J1 Logic Jumper Settings
JP1 1-2 ON = 20A Logic (Factory Setting)
JP1 1-2 OFF = 30A Logic
JP1 7-8 ON = °C Temperature Display (Factory Setting)
JP1 7-8 OFF = °F Temperature Display

Control
Panel

J20

J21

8
6
4
2

Spa Light

J1
7
5
3
1

Temperature Sensor
J2
Hi-limit/Freeze Sensor

BLK J12
Optional
Ozonator

O3

J3

J14

BRN

J16

Transformer
230 VAC
F1*

J11

BLU

F1
20A
250V
SC-20

Hard
Wire
Only

J15

K5

J5
J13
BRN
J6

K7

K8

Heater IN
J17

J7

J8

Heater OUT
J9

J10

BLU BRN

Main Pump BLK
BRN
BLU
LO
HI

GROUND

GRN

Pressure Switch

THERM
SWITCH

Heater
2.7kW @ 230 VAC

BLU
BRN

TB1

BLU
BLU

Standard 3-Wire 230 VAC Connection (50 Hz, 1 Phase Service)

BRN

Use copper conductors ONLY. Wire size must be appropriate per NEC and/or
local codes.

BLU

2 BRN

BRN

1

47

J-200 Series
17.0	Optional Stereo Receiver Functions
1

8

9

2

10

3

11

4

12

13

5

14

6

15

7

16 17

J-230, J-270 and J-280 Models Only:
To start enjoying your new stereo receiver, please read the following
operation instructions in their entirety.
1. Power Button: Press PWR (Power) to turn deck on or off.
2. Equalization Button: Repeatedly press EQ/LD to choose from DSP
Off, Jazz, Pop, Classic, Rock or Vocal equalization options. Press
and hold EQ/LD for 2 seconds to enable or disable the “LOUD”
function.
Special Recommendation: After you have powered up your Aquatic
AV Audio System, we suggest you try one of the preset DSP (digital
sound presets) settings to customize the sound in your spas audio
system. It’s easy, simply press the EQ/LD button (2) to activate the
DSP. Then repeatedly press to choose from Jazz, Pop, Classical, Rock
and Vocal DSP settings. This will enhance your listening experience
and make it more enjoyable.
3. Mute Button: Press Mute to mute audio output. Press again to
return to previous volume level.
4. Open Button: Press Open to flip down the front access panel for CD
access. Gently insert CD into slot (DO NOT FORCE!) Make sure to
close the front panel to prevent damage to the unit.
Note: Never insert a wet or moist CD since it may damage the
mechanism and void the manufacturer warranty.
5. A/PS Button: Press A/PS to scan station presets. The tuner will
scan up, wait for a few seconds, then continue. Once a desired
station is found, press A/PS a second time to cancel scan. To

48

J-200 Series
automatically scan and store station presets, simply press and hold
A/PS for several seconds, then release.
6. DISP Button: Press DISP to switch between clock and station
frequency. When selected, the clock will display for 5 seconds then
automatically revert back to station frequency.
7. Source Button: Press Source to change input from audio or CD
mode to auxiliary mode. Press a second time to switch back.
8. Volume Buttons: Press + (Volume Up) or - (Volume Down) to
increase or decrease volume level.
9.
•
•
•
•
•

SEL Button: Press SEL to choose control function:
Bass
Treble
Balance
Fader
Volume

To adjust selection, press + (Volume Up) or - (Volume Down). Bass
control: Adjusts the amount of low frequency. Treble control: Adjusts
the amount of high frequency. Balance control adjusts the amount
of sound output to the left and right speakers. Fader control adjusts
the amount of sound output. You can decrease the sound level of the
rear speakers by pressing + (Volume Up). To decrease the sound
level of the front speakers press - (Volume Down).
Note: Bass and Treble settings are available only if EQ is set to DSP Off.
10. Preset 1/Pause Play Button: In tuner mode, any station can be
stored as preset 1 by pressing and holding this button for 2 seconds.
To recall the station preset, simply press and release this button. In
CD mode pressing this button will pause or play the CD.
11. Preset 2/INT Button: In tuner mode, any station can be stored as
preset 2 by simply pressing and holding this button for 2 seconds.
To recall the station preset, simply press and release this button. In
CD mode pressing this button will preview each song on the disc for
about 10 seconds. Simply press again to turn off this feature.
12. Preset 3/RPT Button: In tuner mode, any station can be stored
as preset 3 by simply pressing and holding this button for several
seconds. To recall the station preset, simply press and release this
button. In CD mode pressing this button will play a song repeatedly.
Press again to turn off this feature.

49

J-200 Series
1

8

9

2

10

3

11

4

12

13

5

14

6

15

7

16 17

13. Preset 4/RDM Button: In tuner mode, any station can be stored
as preset 4 by simply pressing and holding this button for several
seconds. To recall the station preset, simply press and release this
button. In CD mode press this button to randomly play song tracks.
Press again to turn off this feature.
14. Preset 5/DN Button: In tuner mode, any station can be stored
as preset 5 by simply pressing and holding this button for several
seconds. To recall the station preset, simply press and release this
button. In CD mode this button will browse the folders on CD-R and
CD-RW disks.
15. Preset 6/UP Button: In tuner mode, any station can be stored
as preset 6 by simply pressing and holding this button for several
seconds. To recall the station preset, simply press and release this
button. In CD mode this button will browse the folders on CD-R and
CD-RW disks.
16. BND Button: Press BND to select one of the following frequency
bands: FM1, FM2, FM3, AM1, AM2 and WB (weather band)
17. Tuning UP/DOWN Buttons: Press Track Up to manually adjust
station frequency up. Press and hold Track Up to scan for next
higher station. Scan mode stops as soon as a strong station is found.
Press Track Down to manually adjust frequency down. Press and
hold Track Down to scan for next lower station. Scan mode stops
as soon as a strong station is found. In CD mode pressing these
buttons will advance the CD up or down to the next or previous track.
To fast forward or rewind through a track, simply press and hold
either button as desired during CD playback.
18. Reset Button (Not Illustrated): If keys do not function at all and the
unit appears to be “locked up”, use a ballpoint pen to press the Reset
Button under the front panel (press OPEN to flip down front panel for
access). The Reset Button is located directly below the Eject Button.
Press to clear all memory (except station presets) and reset deck.
Note: This action will reset the display and clock to default setting.

50

J-200 Series
19. Eject Button (Not Illustrated): To eject CD, press OPEN and flipdown the front access panel, then press the Eject button located to
the left of CD slot.
20. USA/Europe Switch (Not Illustrated): You can switch between
American (USA) and European radio frequency bands by flipping a
switch located on the bottom of the deck. To change bands:
• Power down unit.
• Lift up sticker under the CD player.
• Choose desired frequency band as indicated on the sticker.
• Put sticker back in place and power up the unit.
21. Setting The Clock (Unit Must be Off): To set the current time, press
and hold Display (6) for 3 seconds until the clock display starts to
blink, then set hours using the Track Up and/or Track Down button
(17). Press Display a second time to set minutes, using the Track Up
and/or Track Down buttons. Press and hold Display a third time to
exit clock setup (or simply wait for 5 seconds).
22. Selecting Weather Band Mode: Press BND (16) while in tuner
mode until WB displays (deck automatically skips to the strongest
weather channel) or press BND a second time to return to previous
mode. When WB weather band mode is active:
• Press Track Up (17) to scan to higher weather channel.
• Press Track Down (17) to scan to lower weather channel.
• To save a weather channel preset, press and hold one of six numeric
keys 1-6.
Note: Weather channel 7 is not accessible through preset key.
23. Display information DISP:
When a retail music CD is inserted, press DISP (6) to change modes
as follows:
• Clock (displays for 5 seconds only).
• CD track no./Playtime
• When a CD containing MP3 files is inserted, press DISP (6) change
modes as follows:
• Clock (displays for 5 seconds only).
• Track no./Playtime
• Folder name
• File name
• Song name
• Artist’s name
• Album name
The system can only display the first 8 letters of ID3 tags. If the
recorded information is longer than 8 letters, text will scroll to the left
once, then the 8 first letters will be displayed. If specific info has not
been recorded on an MP3 disc, NO FOLD, NO TRK, NO TLT, NO
ALBM, NO ART will display.

51

J-200 Series
24. Playback Order of The MP3 File:
• A directory that does not include an MP3 file is skipped.
• We recommend that you make no more than two levels for each
disc.
• Maximum number of folders: 256
• Maximum number of folder levels: 8
• Maximum number of characters for MP3 file name and folder name:
32
• Sampling frequency: 16 kHz, 22.05 kHz, 24 kHz, 32 kHz, 44.1 kHz,
48kHz
• Bit rates: 8-320 Kbps
• MP3 decoding format: MPEG 1 and 2 Audio Layer 3
• Folder names and file names can be displayed with up to 8
characters (see Display key).
• The characters A-Z, 0-9 can be displayed on this unit, other
characters may not be displayed correctly.
• ID3 tag is supported (see Display key).
25. Reading files into a disc: When a disc containing MP3 data is
loaded, the unit checks all the data on the disc. If the disc contains
numerous folders with many levels, it takes a longer time to start
playback. In addition, it may take time for the unit to move to the
next MP3 file and the fast forward function may not be performed
smoothly. When selected to play, files and folders are accessed in
order in which they were written by the CD writer. Therefore, the
playing order may not be the same as the order in which they are
expected. For example, a disc with the following folder/file hierarchy
is subject to folder select, file select and playback order as illustrated
on page 53.
26.
•
•
•
•
•
•
•
•
•
•
•
•
•
•

52

Optional Audio Receiver Specifications
Marine Grade AM/FM/CD/CD-R/CD-RW/MP-3
7 Bands of Weather Band
Stainless Steel Sealed Chassis and Mounting Hardware
IPX5 Water Intrusion and CFR-46 Rated
Conformal Coated Printed Circuit Boards
ASTMB117 Salt Fog Tested 400 Hours
ASTM D4329 UV Stable Tested 400 Hours
Double Sealed Water Protection Transport Gaskets
White Low Current/Low Heat LCD
White Backlit Control Surfaces
5 Band Digital Sound Stage Settings
200 Watt, 50 x 4
MP3 with ID-3 Tag, Video
Switchable Tuner Frequency U.S. or Euro Band/CE Approved

Level 1 Level 2 Level 3 Level 4 Level 5

Example of a disc's folder/file hierarchy

Folder

File

to return 10 files behind.
to go 10 files forward.

(Track UP) to select folder up

Press

Press and hold 5
Press and hold 6

(Track Down) to select folder down

Press

Operation of the keys

J-200 Series

53

J-200 Series

Serial Number: _ ___________________________
Model Name:

_ ___________________________

Dealer Name: _ ___________________________
Notes: _ __________________________________
_________________________________________
_________________________________________
_________________________________________

54

J-200 Series

55

J-200 Series

56



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-701
Create Date                     : 2009:04:01 15:36:05-07:00
Modify Date                     : 2009:04:10 11:45:02-07:00
Metadata Date                   : 2009:04:10 11:45:02-07:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9742 bytes, use -b option to extract)
Version ID                      : 1
Instance ID                     : uuid:b3a0a6ca-25ff-11de-86d4-0003938051e2
Document ID                     : adobe:docid:indd:61b2599a-0e28-11de-9c7a-9b3769781067
Rendition Class                 : proof:pdf
Derived From Instance ID        : de081956-0e11-11de-9c7a-9b3769781067
Derived From Document ID        : adobe:docid:indd:c1125163-b165-11dd-880b-eacb89d98019
Derived From Version ID         : 1
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 150.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 480.00, 480.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 150.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 480.00, 480.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:9aaf888a-2e0b-11db-9be2-000a95b022d2, uuid:B5793F7609E711DC8DF9C775298A80B3, uuid:F2911F84093A11DC9E50AC84771A9CE4, uuid:98a04962-5042-074a-9436-9c83a83ebf7c, uuid:176537be-f41e-894f-a2af-2adaa879d9e6, uuid:176537be-f41e-894f-a2af-2adaa879d9e6, uuid:827f7feb-2c3c-4d43-9765-98d0e2e817e4, uuid:f6396936-17d3-834a-8cb3-290c001f4dd5, uuid:313cb15a-d10d-ff4b-b81b-b500eda51e6f, uuid:2331eaf7-d84b-ad43-ae64-a8a73dce724d, uuid:8f47f4a3-0d2a-c04b-98e5-824aa59b6a40, uuid:dc700de3-1e35-db46-90da-c1e9186cfb9a, uuid:805fbd49-6610-11dc-8188-0003938051e2, uuid:8c47fb2e-6610-11dc-8188-0003938051e2, uuid:805fbd49-6610-11dc-8188-0003938051e2, uuid:8c47fb2e-6610-11dc-8188-0003938051e2, uuid:ee2de150-2add-5d4a-a9c2-f574787ec11f, uuid:ed87cc12-78ac-9840-be7a-3bff0480ed1a, uuid:8c47fb2e-6610-11dc-8188-0003938051e2, uuid:805fbd49-6610-11dc-8188-0003938051e2, uuid:a30ece73-c487-7f41-ba93-52c206ca826e, uuid:499ede16-f1e1-e64c-b292-993000aab6a7, uuid:8c47fb2e-6610-11dc-8188-0003938051e2, uuid:805fbd49-6610-11dc-8188-0003938051e2, uuid:8c47fb2e-6610-11dc-8188-0003938051e2, uuid:805fbd49-6610-11dc-8188-0003938051e2, uuid:df0c6c8d-1431-f548-9003-8de4419eddff, uuid:ee2de150-2add-5d4a-a9c2-f574787ec11f, uuid:dc700de3-1e35-db46-90da-c1e9186cfb9a, uuid:3a971384-b124-a543-841a-5bb061876a87, uuid:4b74a70d-0e27-2d4a-860d-ec8ee87dba07, uuid:3a971384-b124-a543-841a-5bb061876a87, uuid:DAC66960EA9A11DB94DCA39C1DF0C6A2, uuid:4c0c106e-e04f-dd45-8071-1cec03125065, uuid:070238852AF7DC11A6DCB80924BAD0AA, uuid:8c47fb2e-6610-11dc-8188-0003938051e2, uuid:805fbd49-6610-11dc-8188-0003938051e2, uuid:8c47fb2e-6610-11dc-8188-0003938051e2, uuid:805fbd49-6610-11dc-8188-0003938051e2, uuid:00cab54e-242f-fc4c-a210-f1142ec90337, uuid:c3960b92-4523-ff4e-811e-f15c94772266, uuid:12026ab2-c60c-fb44-abb7-0b6c3b8a8dc0, uuid:c9b5b954-2cb5-1444-9b50-fa85f9726d80, uuid:c3960b92-4523-ff4e-811e-f15c94772266, uuid:12026ab2-c60c-fb44-abb7-0b6c3b8a8dc0, uuid:8126334a-aa1e-be4c-9588-9017cc5f71bd, uuid:aee100c5-5217-5644-b315-ab794b0866db, uuid:21bf7fa9-c948-ed44-bbcb-a70ec9703bef, uuid:13800da6-fe08-3249-a85a-0e8c2b46e851, uuid:3a31dd58-d25b-c548-b681-10f300e67ef2, uuid:65cd4fcf-2d23-d649-8b1a-034fdda34077, uuid:f1a3703b-3bb2-ca49-acb9-fbe0c5c0f681, uuid:ef2da56a-34cb-4b42-a79a-2a0634045481, uuid:61cf3c72-1a16-0946-93d4-a09e64c83363, uuid:1597174a-2d56-6449-8132-82cad847e43e, uuid:436648856C1A11DC926FAF5BADCF6A82, uuid:CE7DE36D6E7511DC81FF8D05CC597A90, uuid:176537be-f41e-894f-a2af-2adaa879d9e6, uuid:5097659f-5f1f-644a-abd9-83a29b1b8c6b, uuid:9f0aca30-e02d-0946-82e7-cb2d6155aa42, uuid:55555f0b-4937-f14f-adbe-2f21fa9c0034, uuid:127fa27c-172c-7247-a05f-32f2da0b304c, uuid:c41ac26d-9ff0-354a-a36e-78bca1c47de2, uuid:19987db5-e13c-0642-9949-72ce30ced623, uuid:19987db5-e13c-0642-9949-72ce30ced623, uuid:0ab53e77-a990-164c-90cb-28a5f0c68e94, uuid:70f01ea7-797a-9646-a2c9-95015409dc14, uuid:42308fa0-eed0-e244-95f6-697036eeb63d, uuid:95460130-a7d7-504e-80a3-fbf80270b2c8, uuid:845d2ecc-4b98-2a41-b137-d92b64bb29d8, uuid:97f34804-563b-fd44-9fb4-256d37a7860e, uuid:67f3cee7-3251-3a4b-b348-149c9480b4fe, uuid:67f3cee7-3251-3a4b-b348-149c9480b4fe, uuid:2b9071e5-6080-11dc-85b6-0003938051e2
Manifest Reference Document ID  : uuid:D6837D8D2F5C11DB8097C14093ECA18D, uuid:B5793F7509E711DC8DF9C775298A80B3, uuid:F2911F80093A11DC9E50AC84771A9CE4, uuid:6244E2EAFD03DE11A9ABDBFD82E1C91B, uuid:21F7CCD0F1F5DD1195CDCB8FC5A1DB15, uuid:21F7CCD0F1F5DD1195CDCB8FC5A1DB15, uuid:5965D5F55EDA11DC8122A4EAE3AE63C9, uuid:20E068FF6E9611DCA90CDA5DE3E0686D, uuid:20E069016E9611DCA90CDA5DE3E0686D, uuid:20E069036E9611DCA90CDA5DE3E0686D, uuid:20E069056E9611DCA90CDA5DE3E0686D, uuid:5965D5F95EDA11DC8122A4EAE3AE63C9, uuid:25A36F57676811DC8C4D982736C799FF, uuid:25A36F59676811DC8C4D982736C799FF, uuid:25A36F57676811DC8C4D982736C799FF, uuid:25A36F59676811DC8C4D982736C799FF, uuid:5965D5FD5EDA11DC8122A4EAE3AE63C9, uuid:94CD25785EE811DC8122A4EAE3AE63C9, uuid:25A36F59676811DC8C4D982736C799FF, uuid:25A36F57676811DC8C4D982736C799FF, uuid:94CD257A5EE811DC8122A4EAE3AE63C9, uuid:94CD257C5EE811DC8122A4EAE3AE63C9, uuid:25A36F59676811DC8C4D982736C799FF, uuid:25A36F57676811DC8C4D982736C799FF, uuid:25A36F59676811DC8C4D982736C799FF, uuid:25A36F57676811DC8C4D982736C799FF, uuid:94CD257E5EE811DC8122A4EAE3AE63C9, uuid:5965D5FD5EDA11DC8122A4EAE3AE63C9, uuid:5965D5F95EDA11DC8122A4EAE3AE63C9, uuid:770A6B02676C11DC8C4D982736C799FF, uuid:8D444B8C57B611DC8105C1F53590A943, uuid:770A6B02676C11DC8C4D982736C799FF, uuid:9E0D824CEA9611DB94DCA39C1DF0C6A2, uuid:F36094EB610B11DC882CA7B967742DC9, uuid:A0F35BA05EE811DC9E3EE7F827AD7C6E, uuid:25A36F59676811DC8C4D982736C799FF, uuid:25A36F57676811DC8C4D982736C799FF, uuid:25A36F59676811DC8C4D982736C799FF, uuid:25A36F57676811DC8C4D982736C799FF, uuid:F36094F0610B11DC882CA7B967742DC9, uuid:F36094F2610B11DC882CA7B967742DC9, uuid:2EE3D9CE611511DC882CA7B967742DC9, uuid:2EE3D9D0611511DC882CA7B967742DC9, uuid:F36094F2610B11DC882CA7B967742DC9, uuid:2EE3D9CE611511DC882CA7B967742DC9, uuid:2EE3D9D2611511DC882CA7B967742DC9, uuid:134D7C8A611D11DC882CA7B967742DC9, uuid:2EE3D9D7611511DC882CA7B967742DC9, uuid:217D9383644F11DCAFD7AB2973FFB4C9, uuid:134D7C8D611D11DC882CA7B967742DC9, uuid:134D7C8F611D11DC882CA7B967742DC9, uuid:134D7C91611D11DC882CA7B967742DC9, uuid:134D7C93611D11DC882CA7B967742DC9, uuid:A3F30539612811DC882CA7B967742DC9, uuid:A3F3053B612811DC882CA7B967742DC9, uuid:436648846C1A11DC926FAF5BADCF6A82, uuid:0C8C9B796E7411DC81FF8D05CC597A90, uuid:21F7CCD0F1F5DD1195CDCB8FC5A1DB15, uuid:99B0C3D762DF11DC9D8585B1E89643A1, uuid:51161E425C8711DC90A5B0E77EEF4D6F, uuid:51161E445C8711DC90A5B0E77EEF4D6F, uuid:2B368AE45C7B11DC90A5B0E77EEF4D6F, uuid:2B368AE65C7B11DC90A5B0E77EEF4D6F, uuid:9470812985B8DD11903DEAA9FCDD615A, uuid:9470812985B8DD11903DEAA9FCDD615A, uuid:51161E465C8711DC90A5B0E77EEF4D6F, uuid:51161E485C8711DC90A5B0E77EEF4D6F, uuid:756CAF40614411DC899DAB3B99CBE2EC, uuid:F826823B637111DCB128D9C13B03E348, uuid:31E1B5D36F3811DCA48183038BBEA605, uuid:F8268239637111DCB128D9C13B03E348, uuid:C34A60831CB211DC9ED9C33C1F016021, uuid:C34A60831CB211DC9ED9C33C1F016021, uuid:D13448EB61D711DC92E2A6B3085926A4
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 60
Page Layout                     : SinglePage
Creator                         : Adobe InDesign CS3 (5.0.4)
EXIF Metadata provided by EXIF.tools

Navigation menu