Japan Radio NKE1066 MARINE RADAR User Manual 2
Japan Radio Co Ltd. MARINE RADAR 2
Contents
- 1. User Manual 1
- 2. User Manual 2
- 3. User Manual 3
- 4. User Manual 4
- 5. User Manual 5
User Manual 2
Chapter 2 START THE BASIC OPERATION Chapter 2 START THE BASIC OPERATION When * basic adjustment is made by the serviceman etc. beforehand, please perform as it is. (In case of no adjustment is done by the serviceman etc. beforehand, please through eyes to Chapter 5 for the time being, and after getting to know the outline of operation of this radar, perform Initial setting of Chapter 7.) The screen is a touch screen and can be operated by tracing a screen by a finger flip or touching. The term of operation: TAP: Push a screen display position once by a fingertip. Flick: Rub a screen display position by a fingertip. (A state recognized according to the rubbed direction) Swipe: Rub a screen display position keeping on touch by a fingertip. Long tap: Pushing a screen display position, continued more than 3 seconds or more by a fingertip. The operation of a Rotary knob: Click: Push in a Rotary knob once. Rotating and choosing the state of a screen, then click and fix. General using : The touch panel function is select absolute positions on panel, on the other hands, Rotary knob select sequential data up and down. and, at selection data appeared then click and fix. Only Cross cursor is individual moving, no relation to another. 29 Chapter 2 START THE BASIC OPERATION Power on startup screen. Push PWR/CLR button. Startup screen. (3 Startup screen possible to select.) Swipe on the screen for select the startup screen. 30 Chapter 2 START THE BASIC OPERATION Rotary knob. Push Rotary knob and rotate to select the starting item.. Select the icon you needed by turning the knob Tap icon at bottm side, then full icons can be seen. Full icons will be appeared. Keep press and rotate the rotary knob, then screen brillance menu will be open. The turn while pressing Brillance menu will be appeared. Rotate Rotary knob at suitanble brilliande level. Release Rotary knob, then the brillance level is fixed 31 Chapter 2 START THE BASIC OPERATION Sleep Cursor Tap Sleep TX/STBY Tap TX/STBY Tap TX/STBY Activate Cursor Tap Activate TX/STBY After a few seconds, the icons fade out. Push or click the Rotary knob. Crick the Rotary knob will appear the icons 32 Chapter 2 START THE BASIC OPERATION 2 - 1 G UI D E F OR O P E R A TI ON Front view Multi-Touch screen. ☆ Operate using “tap” “flick” long tap” “swipe” by fingertip. Rotary knob. ☆ Rotation: select the sequential menu. ☆ Push or click fix menu data. POWER ON OFF, CLEAR PUSH BUTTON. ☆ POWER ON/OFF ☆ CLEAR OF MENU 2 - 2 P O W ER O N ( S T A N D B Y F O R TR A N SMI T) PRESS PWR / BUTTON Startup screen Start to display screen. 33 Chapter 2 START THE BASIC OPERATION 2 - 3 DI S P L A Y S C R E EN 2-3-1 SCREEN LAYOUT Course Speed (through ground) Own ship. Range Longitude/Latitude. depth. Range interval Own ship position mark. Alarm Speaker USB Port 34 POWER ON OFF,CLEAR PUSH BUTTON. Push Rotary knob, then appears some menu. ☆ POWER ON/OFF Rotation of Rotary knob can select menu of activated icon. ☆ CLEAR OF MENU Function call icon will be displayed. Chapter 2 START THE BASIC OPERATION Various ST-BY screen. Tap White dot Tap △ Normal ST-BY screen, Normal ST-BY screen, * ST-BY Disp, Select.: Normal ST-BY screen, “Normal” Tap White dot Graphical ST-BY screen * ST-BY Disp, Select.: Course Tap △ Graphical ST-BY screen ”Graphical” Speed Course Tap White dot Numeric Display ST-BY screen. Course Speed Speed Tap △ Own ship position Own ship position * ST-BY Disp, Select.: Graphical ST-BY screen Numeric Display ST-BY screen. Own ship position Numeric Display ST-BY screen. “Numeric Display” 35 Chapter 2 START THE BASIC OPERATION TX screen. Push Rotary knob, select TX icon by rotating Rotary knob and push Rotary knob. Push Rotary knob & select TX icon by rotating. Set focus to TX icon. Or Start TX Push Rotary knob Tap TX icon Tap △ Tap ▽ Push Rotary knob 36 Tap UP icon Tap DOWN icon Chapter 2 START THE BASIC OPERATION 2-3-2 ICON’S TABLE The icons which will appear by screen operation. GAIN RAIN VRM GURDZONE CURSOR MODE RIVER SETTING MODE FIOAT SEA MARK MENU MODE OFF BRILLIANCE AIS USER1 DAY TX-STBY TT USER2 NIGHT RANGE MOB EBL OFFCENTER MODE STANDARD MODE COAST 37 Chapter 2 START THE BASIC OPERATION Display the function icons. Appear icons after Pushing Rotary knob No operation about 10 second. Push Rotary knob Rotate for icon selection. Selected icon is focused. Push Rotary knob, then appear the setting menu. Set level by Rotary knob or flick bar graph.. Then push Rotary knob, data is fixed. 38 Rotate Rotary knob Chapter 2 START THE BASIC OPERATION Tap TX/STBY icon, or Push rotary knob when TX/STBY icon is focused. TX Scanned display is appeared ST-BY Tap icon or push rotary knob Tap icon or push rotary knob 39 Chapter 2 START THE BASIC OPERATION Tap GAIN Adjust icon, or Push rotary knob when GAIN Adjust icon is focused. The case of ST-BY The case of TX Adjustment Gain Adjustment Gain Bar is appeared Bar is appeared Tap “Auto” of Gain setting mode Tap “Auto” of Gain setting mode Gain is set automatically. Rotate the rotary knob with monitoring green bar. Flick the green bar Or Tap “+” or “-“ Or ※In TX mode, can be adjusted while monitoring the display echo. Tap return icon Push Rotary knob Or The data is fixed, and then return 40 Chapter 2 START THE BASIC OPERATION Tap SEA Adjust icon, or Push rotary knob when SEA Adjust icon is focused. Adjustment Bar is appeared Tap “Auto” of SEA setting mode Tap “Auto” of SEA setting mode SEA is set automatically. Rotate the rotary knob with monitoring green bar. Flick the green bar Or Tap “+” or “-“ Or ※Can be adjusted while monitoring the display echo. Tap return icon Push Rotary knob Or The data is fixed, and then return 41 Chapter 2 START THE BASIC OPERATION Tap RAIN Adjust icon, or Push rotary knob when RAIN Adjust icon is focused. Adjustment Bar is appeared Tap “Auto” of RAIN setting mode Tap “Auto” of RAIN setting mode RAIN is set automatically. Rotate the rotary knob with monitoring green bar. Flick the green bar Tap “+” or “-“ Or Or ※Can be adjusted while monitoring the display echo. Tap return icon Push Rotary knob Or The data is fixed, and then return 42 Chapter 2 START THE BASIC OPERATION 2-3-3 BRIEF EXPLANATION OF ICON’S FUNCTION Brief explanation of each icon. GAIN (gain control) adjustment: Set up the sensitivity of Radar echo.. SEA (sea-clutter rejection) adjustment: Control the sea clutter level near the ship. Long distant echo gain is remaining as it is, and gain is lowered as to short distance. Adjust the target ship is clearly observe and reject the sea clutter on screen as much as possible. RAIN (rain-and-snow-clutter rejection) adjustment: This type radar uses (X) band microwave (wavelength: 3cm). This microwave can detectable more far range in fine weather, but in rain or snow weather, the detectable range decrease remarkably. The control is adjusted for separate the target and rain or snow as long as possible. BRILL (brightness) adjustment: Set up the brightness of a screen. It sets up brightly daytime and sets up not dazzle at night MOB (Man Over the Boat): When the crew fall into over the boat by accident. Carry out a tap MOB icon immediately. The radar memorizes the place latitude and longitude information, and continues displaying the (MOB)place on a screen. When going to rescue, navigator can take course to the(MOB)point on screen. (Important: GPS signal must be connected in this function.) TT DATA (target tracking) Data which is tracking automatically is displayed. Data is display the direction, the distance, the speed. This function must be required the heading signal and log signal. Measures reading of a direction can select from north(N-UP) and measure from self-ship (H-UP). The speed display can select the relative speed mode or absolute speed mode. 43 Chapter 2 START THE BASIC OPERATION AIS DATA (when received the AIS signal, the data of MMSI of the vessel which has transmitted, latitude, longitude, a direction of movement, speed, rate of turn, etc. is displayed.) (AIS receiver signal is necessary.) EBL (electronic bearing line) Measure the target direction by using cursor line. VRM (variable range marker) Measure the target distance by using circle line. Off-center (Normally own position is the center of screen, but it is possible to move own position from fixed center of screen). Tap the icon will shift the own position. Shifting point are fixed 5 positions only. TX (transmission), ST-BY (standby) Whenever it carries out a tap, transmission and ST-BY are changed. RANGE (range scale) The range scale to observe is changed. The maximum range is limited by the scanner type which is connected. NKE-1066 scanner 0.0625NM 0.125NM 0.25NM 0.5NM .075NM 1.5NM 3NM 6NM 12NM 24NM. (Also 1NM, 2NM, 4NM, 8NM, 16NM are possible by system menu setting.) NKE-2044 scanner 0.0625NM 0.125NM 0.25NM 0.5NM .075NM 1.5NM 3NM 6NM 12NM 24NM 48NM. (Also 1NM, 2NM, 4NM, 8NM, 16NM, 32NM are possible by system menu setting.) 44 Chapter 2 START THE BASIC OPERATION Various system setups. Tap the icon, the adjustment menu will be displayed. Choose the item to set up individually. Code input “0” is setting for service menu. Next User menu Special setting menu for user. 45 Chapter 2 START THE BASIC OPERATION GUARD ZONE setup Set up the watching area around own-ship. If a target goes into the set-up area, generate the alarm sound or signal.. On the other hand, if a target goes out the set-up area, generate the alarm sound or signal, too. One of both is possible to select. Cursor: A tap is carried out, start, drag and tap off on the target. The position of this cursor is indicated. Various kinds of pointing actions uses this cursor.. Tracking of target, AIS data display, setting of guard zone, etc. MARK: Use when plot a mark on the screen. Moreover, also when deleting an unnecessary mark, it uses. 46 Chapter 2 START THE BASIC OPERATION 2 - 4 T R A N SMI T (90 seconds pre-heat time is required for cold start, because of the Magnetron heater.) After 90 seconds, anytime transmitting is possible. Various ST-BY screen. Power ON Push PWR/CLR button 47 Chapter 2 START THE BASIC OPERATION Start by “the tapping white dot” or “the pushing rotary knob” White dot White dot rotary knob “Tap TX/ST-BY icon” or “Select TX/ST-BY icon and push rotary knob”, and then transmitting. TX/ST-BY icon Select TX/ST-BY icon and push rotary knob rotary knob Transmitting screen. No operation of 10 second, small menu will be fade out. 48 Chapter 2 START THE BASIC OPERATION 2 - 5 L E A V E T H E U S E F U L I C O N O N S C R E EN How to copy icon. Basic icon display. Fixed icon (TX/ST-BY, Gain) User free area of menu icon. Tap UP icon Full icon display icons that can be copied to user free area. Fixed icon (TX/ST-BY, Gain) User free area of menu icon. Tap and hold the icon, Tapped icon is copied to free menu area Up to 4 icons can copy the user free area. 49 Chapter 2 START THE BASIC OPERATION How to remove icon. Full icon display Basic icon display. Tap and hold the icon, on user free area Tapped icon is removed from free menu area Then the remaining icons are shifted to the left. How to add another icon. Tap and hold the icon, Tapped icon is copied to free menu area 50 Chapter 2 START THE BASIC OPERATION 2 - 6 F U N C TIO N C A LL B Y S C R E E N T A P Various types of icon. (1) Start function immediately. (2) Move into function setting. (3) Double tap start from resist setting state and open menu. TX, ST-BY Every tap changes TX, ST-BY alternately Change Range tap increase range tap decrease range Or While range icon focused Or Rotate the rotary knob with monitoring range. Or Change brightness by Flick the green belt. Tap “+” or “-“ 51 Chapter 2 START THE BASIC OPERATION Screen brightness adjustment Tap the icon, then display Adjust menu. Or Or Rotate the rotary knob with monitoring green bar. Change brightness by Flick the green belt. Tap “+” or “-“ Setting level is displayed down side of each icon. Green bar length is proportion to setting level. Also using Rotary knob is possible to adjust. Keep press on the Rotary knob and turn. Anytime it’s possible to change Keep press on the Rotary knob. *”POWER ON–OFF” is operate from “PWR/CLR BUTTON!” only. Can’t control from screen menu. 52 Chapter 3 ADJUST THE RADAR ECHO Chapter 3 ADJUST THE RADAR ECHO ▽ △ 3 - 1 C H A NG E R AN G E tap decrease range tap increase range This picture is selected 1.5 nm range. Outer dashed line shows the maximum observation RANGE range. RANGE RING INTAVAL Gain is easily changed by the tap of increase / decrease icon as shown in the figure below tap increase range tap decrease range Or 1.5NM Adjust while range icon focused by tapping or selection of rotary knob Or Rotate the rotary knob with monitoring green bar. Or Change brightness by Flick the green belt. Tap “+” or “-“ 53 Chapter 3 ADJUST THE RADAR ECHO Range scale, NKE-1066 scanner It changes to 0.0625NM 0.125NM 0.25NM 0.5NM .075NM 1NM 1.5NM 2NM 3NM 4NM 6NM 8NM 12NM 16NM 24NM and order. NKE-2044 scanner It changes to 0.0625NM 0.125NM 0.25NM 0.5NM .075NM 1NM 1.5NM 2NM 3NM 4NM 6NM 8NM 12NM 16NM 24NM 32NM 48NM and order. A picture will change on a scale as shown in the following figure, as range changes. The radius of the circle shows the range. Example: Video change 0.0625NM 0.125NM 0.25NM 1.5NM 2NM 3NM 12NM 16NM 24NM 32NM 0.5NM 0.75NM 1NM 4NM 6NM 8NM 48NM is NKE-2044scanner only 54 Chapter 3 ADJUST THE RADAR ECHO 3 - 2 A D J U S T S G AI N ( R AD A R S E N SI TI VI T Y) Radar must be set suitable gain, or can’t use as a radar Adjust while Gain icon focused by tapping or selection of rotary knob icon’s green belt show the adjusted level of GAIN How to change the Gain: See the method of Gain adjustment of Chapter2 Example of echo sensitivity as following echo sensitivity Low 6NM echo sensitivity Middle echo sensitivity 6NM High 6NM If GAIN control is the maximum, noise will appear on whole screen. GAIN set Exceed On clear weather normally set almost maximum GAIN. When rough weather or rough sea or heavy rain and, snow, adjust mix up SEA,RAIN GAIN. And select suitable level each. 6NM 55 Chapter 3 ADJUST THE RADAR ECHO 3 - 3 A D J U S T S E A ( C L U T TE R C ON T R O L) Radar must be set suitable sea control, or can’t use as a radar Adjust while SEA icon focused by tapping or selection of rotary knob icon’s green belt show the set level of SEA How to change the SEA: See the method of SEA adjustment of Chapter2 SEA Level Low 0.5NM 56 SUITABLE Level 0.5NM Chapter 3 ADJUST THE RADAR ECHO 3-4 ADJUST RAIN AND SNOW CLUTTER CONTROL Radar must be set suitable rain and snow control, or can’t display the suitable picture. Adjust while RAIN icon focused by tapping or selection of rotary knob icon’s green belt show the set level of RAIN How to change the RAIN: See the method of RAIN adjustment of Chapter2 RAIN Small (usually) 6NM RAIN Excessive (the target of the radius direction becomes small.) clear weather (RAIN 0) (RAIN *). Rain control is effective, if the weather light rain or snow. Too much suppression will disappear the small target, so set a little. 6NM not clear weather (RAIN 0). (RAIN *) 57 Chapter 3 ADJUST THE RADAR ECHO 3 - 5 A D J U S T B RI L LI A N C E OF S C R E E N Double TAP of screen can change BRILLANCE of screen. Normal TAP, Flick operations also possible to change screen brilliance. range. Double Tap icon’s green belt show the set level of BRILLIANCE How to change the BRILLIANCE: See the method of BRILLIANCE adjustment of Chapter2 58 Chapter 3 ADJUST THE RADAR ECHO ****FOR REFERENCE**** **** **** Observing the Radar screen, GANI and SEA control adjustment is essential adjustment. RAIN: Normally set “0”, when light rain or snow, turn proportion to reject rain noise on screen. GAIN: Set the GAIN adjustment for long range (more than 6nm) target can observe clear. Under this conditions, short range near own ship, cannot observe small target because of high clutter and high gain. To avoid this failure, use SEA control, and suppress near range clutter noise. If suitable adjustment is done, costumer can observe clear target from short range to long range. ACTUAL OPERATION Set RAIN Minimum position ① Set 6nm RANGE, and observe more farther special target. Set GAIN control so as to the special target is observe clearly. Change to 0.5nm RANGE Set SEA control so as to the near target can observe clearly. ② Basically, RAIN control is minimum state, but according to the weather conditions, to reject rain or snow clutter, little bit turn to effective point. 59
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2014:01:06 13:51:25-08:00 Create Date : 2014:01:06 13:50:58-08:00 Metadata Date : 2014:01:06 13:51:25-08:00 Creator Tool : CubePDF Format : application/pdf Document ID : uuid:a1e1a33b-81d0-4176-ad43-c908e57a07b4 Instance ID : uuid:fa2a3784-c8a3-4e81-9847-f913ac13a5ce Producer : GPL Ghostscript 9.07; modified using iTextSharp™ 5.4.2 ©2000-2012 1T3XT BVBA (AGPL-version) Has XFA : No Page Count : 31 Creator : CubePDFEXIF Metadata provided by EXIF.tools