Japan Radio NKE2044 MARINE RADAR User Manual 5
Japan Radio Co Ltd. MARINE RADAR 5
Contents
- 1. User Manual 1
- 2. User Manual 2
- 3. User Manual 3
- 4. User Manual 4
- 5. User Manual 5
User Manual 5
Chapter 8 DETAIL PERFORMANCE SETTING Chapter 9 MAINTENANCE AND CHECK 9 - 1 R O U TI N E M AI NT E N AN C E For operating the radar equipment in the good conditions, it is necessary to make the maintenance work as described below. If maintenance is made properly, troubles will reduce. It is recommended to make regular maintenance work. Common points of maintenance for each unit are as follow: Clean the equipment. Remove the dust, dirt, and sea water rest on the equipment cabinet with a piece of dry cloth. Especially, clean the air vents with a brush for good ventilation. 138 Chapter 9 MAINTENANCE AND CHECK 9 - 2 M AI N T EN A N C E OF E A C H U NI T 9-2-1 SCANNER NKE-1066 DANGER When conducting maintenance work on the antenna, make sure to turn its main power off. Failure to comply may result in electrocution or injuries. 139 Chapter 9 MAINTENANCE AND CHECK 9-2-2 SCANNER NKE-2044 DANGER When conducting maintenance work on the antenna, make sure to turn its main power off. Failure to comply may result in electrocution or injuries. 140 Chapter 9 MAINTENANCE AND CHECK 9-2-3 DISPLAY NCD-2256 DANGER When cleaning the display screen, do not wipe it too strongly with a dry cloth. Also, do not use gasoline or thinner to clean the screen. Failure to comply will result in damage to the screen surface. Dust accumulated on the screen will reduce clarity and darken the video. For cleaning it, wipe it with a piece of soft cloth (flannel or cotton). Do not wipe it strongly with a piece of dry cloth nor use gasoline or thinner. 141 Chapter 9 MAINTENANCE AND CHECK 9 - 3 P E R F OR M A NC E C H EC K Make operational check on the radar equipment regularly and if any problem is found, investigate it immediately. Pay special attention to the high voltage sections in checking and take full care that no trouble is caused by any error or carelessness in measurement. Take note of the results of checking, which can be used effectively in the next check work. Operational check shall be made in accordance with Table 4.3-1 Function Check List in the order as specified in it. Table 9-3-1 Performance Check List 142 Chapter 9 MAINTENANCE AND CHECK 9-3-1 TEST MENU The performance status of this radar equipment can be checked on the Test Menu. 9-3-2 SYSTEM INFORMATION Displays the current system information. (software version information). 9-3-3 SYSTEM TIME Displays the following system time information. ■ Indicator Running Time ■ Scanner Transmit Time ■ Scanner Motor Time ■ Scanner Running Time 143 Chapter 9 MAINTENANCE AND CHECK 9-3-4 SCANNER INFORMATION Displays the following scanner information. ■ Transmitted output power ■ Motor Type ■ Magnetron Current 9-3-5 HARDWARE INFORMATION Displays the following hardware information. ■ Serial Number ■ MAC Address ■ Temperature 9-3-6 ERROR LOG The error log displays previously occurred system alarms with the dates and times when they occurred. 9-3-7 LINE MONITOR Serial communication data can be seen on the built-in Line monitor. Line monitor can be used to make sure that the serial data are received properly 144 Chapter 9 MAINTENANCE AND CHECK 9-3-8 SELF TEST The following tests can be performed. ■ Key Test ■ Buzzer Test ■ Key Light Test ■ Monitor Display Test ■ Memory Test ■ Line Test ■ Sensor Test 145 Chapter 9 146 MAINTENANCE AND CHECK Chapter 9 MAINTENANCE AND CHECK 9 - 4 R E P L AC E M EN T O F MAJ O R P A R T S 147 Chapter 9 MAINTENANCE AND CHECK 9-4-1 PARTS REQUIRED FOR PERIODIC REPLACEMENT Here are parts required for periodic replacement. PARTS NAME 148 1. MAGNETRON 2. MOTOR INTERVAL 4,000 HOURS 10,000 HOURS Chapter 9 MAINTENANCE AND CHECK 9 - 5 F A U L T FI N DI NG 9-5-1 ALARMS AND OTHER DISPLAY LISTS 9-5-2 FUSE 9 - 6 T R O UB L E S H OO T IN G 9-6-1 INCLUDED ACCESSORIES 9-6-2 SPECIAL PARTS Location Parts No. Name Type Code Manufacture NKE-1066 V101 Magnetron M1624 NKE-2044 V101 Magnetron MSF1421B 5VMAA00092 New JRC NKE-2044 A101 Circulator FCX68R 5AJIX00027 Orient Microwave NKE-2044 A102 Diode Limiter NJS6930 5ATBT00006 New JRC New JRC 149 Chapter 9 MAINTENANCE AND CHECK 9-6-3 CIRCUIT BLOCK TO BE REPAIRED JMA-1032 Location Circuit Block Type Remarks Scanner Motor unit H-7BDRD0053 Scanner Modulation circuit CME-396 Include IF Amplifier Scanner Micro wave unit Transmitter/ receiver CMN-924/NZT-1066 Include Receiver frontend Display Unit Power Supply circuit CBD-1928 Display Unit Process Circuit CDC-1433 Display Unit LCD Panel NZP-2256 JMA-1034 Location 150 Circuit Block Type Remarks Scanner Motor unit H7BDRD0052A Scanner Modulation circuit CME-397 Scanner Receiver NRG-242 Display Unit Power Supply circuit CBD-1928 Display Unit Process Circuit CDC-1433 Display Unit LCD Panel NZP-2256 NZT-2044 Chapter 9 MAINTENANCE AND CHECK 151 Chapter 10 AFTER-SALE SERVICE Chapter 10 AFTER-SALE SERVICE 1 0 - 1 K E E PI N G P E RI O D O F M AI N T EN A NC E P A R TS Keeping period of maintenance parts is ten years from the production is discontinued. 1 0 - 2 W H E N Y O U R E Q U E ST F O R R E P AI R If you suppose the product may be out of order, read the description in "9-2-5 FAULT FINDING" and "9-2-6 TROUBLE SHOOTING", and check the suspected point again. If it is still out of order, you are recommended to stop operation of the equipment and consult with the dealer from whom you purchased the product, or our branch office in your country or district, the sales department in our main office in Tokyo. ● Repair within the Warranty Period If any failure occurs in the product during its normal operation in accordance with the instruction manual, the dealer or JRC will repair free of charge. In case that any failure is caused due to misuse, faulty operation, negligence or force major such as natural disaster and fire, the product will be repaired with charges. ● Repair after the Warranty Period. If any defective function of the product is recoverable by repair, the repair of it will be made at your own charge upon your request. ● Necessary Information for Repair Product name, model, manufacturing date and serial number Trouble conditions (as detailed as possible. Refer to page "10-4 Radar failure check list".) Name of company/organization, address and telephone number 1 0 - 3 R E C OM M E N D ED M AI NT E N AN C E The performance of the product may deteriorate due to the secular change of the parts used in it, though such deterioration depends upon the conditions of operation. So checkup and maintenance is recommendable for the product in addition to your daily care. For maintenance, consult with the near-by dealer or our sales department. Such maintenance will be made with charges. For further details of after-sale service, contact the JRC Offices. 152 Chapter 10 AFTER-SALE SERVICE 1 0 - 4 R A DA R F AI L U RE C H E C K LI S T 153 Chapter 11 DISPOSAL Chapter 11 DISPOSAL 1 1 - 1 DI S P O S A L O F T H E U NI T When disposing of this unit, be sure to follow the local laws and regulations for the place of disposal. 154 Chapter 11 DISPOSAL 1 1 - 2 DI S P O S A L O F U S E D M A GN E T R ON A magnetron is used for the scanner (NKE-1066) (NKE-2044). ☆ When the magnetron is replaced with a new one, return the used magnetron to our dealer or business office. For detail, consult with our dealer or business office. 1 1 - 3 C HI N A R O H S 155 Chapter 11 156 DISPOSAL Chapter 12 SPECIFICATIONS Chapter 12 SPECIFICATIONS NKE-1066 scanner NCD-2256 display 1.5ft scanner 4kw Radome diameter φ450mm NKE-2044 scanner Display 7inches wide LCD 2ft Scanner 4kw Radome diameter φ620mm 158 Chapter 12 SPECIFICATIONS 1 2 - 1 S C A NN E R DI M E N SI O N 12-1-1 NKE-1066 NKE-1066 1.5ft scanner 4kw radome φ450mm 4-φ40 RUBBER PLATE 159 Chapter 12 SPECIFICATIONS 12-1-2 NKE-2044 160 Chapter 12 SPECIFICATIONS 1 2 - 2 DI S P L A Y DI M EN SI O N 12-2-1 NCD-2256 161 Chapter 12 162 SPECIFICATIONS Chapter 12 SPECIFICATIONS 1 2 - 3 E Q UI PM E N T OU T LI N E 1)This equipment is a marine radar for vessels and work boats which consists of the display unit including 7 inch wide VGA color LCD Monitor unit, Keyboard unit, Processing unit and consists of the 1.5 ft /2ft radome type scanner unit. The processing unit uses SOC (LUPIM) developed by JRC and the LCD monitor unit uses panel with touch sensor (resistance film type). The operation can be realized intuitive and simple. 12-3-1 CONFIGULATION CONFIGURATION 12-3-1 1) Display unit NCD-2256 ・ Integrated the 7 inch wide VGA color LCD Monitor unit, Keyboard unit and Processing unit 2) Scanner unit ・ X-band 1.5ft(4kW) ・ X-band 2ft(4kW) radome type is NKE-1066 radome type is NKE-2044 12-3-2 FEATURE 1) The screen resolution is 800x480dots (WVGA). The LCD monitor unit with touch sensor (resistance film type). 2) Highly efficient signal processing using the SOC including DSP. 3) TT and AIS function are prepared by SOC using. 12-3-3 RADAR MODEL JMA-1032 JMA-1034 1.5ft Scanner unit 2.ft Scanner unit 163 Chapter 12 SPECIFICATIONS 12-3-4 SYSTEM DIAGRAM JMA-1030 Series system diagram 1.5feet Scanner Unit (NKE-1066) Radome diameter 450mm 2feet Scanner Unit (NKE-2044) Radome diameter 620mm CFQ9924-5,10,15,20,300 *STANDARD LENGTH 10m OPTION: (cablelength:5m/15m/20m/30) JMA-1032 RADAR JMA-1034 RADAR External Navigational Signal input. NMEA 3 input ports (GPS,AIS,DEPTH) Ship’s Main Power (10.8-31.2VDC) CFQ-9900 (cable length 2m) *INCLUDING FUSE IN PLUS LINE FUSE TYPE: 7.5A/58V 164 7inch WIDE VGA COLOUR LCD DISPLAY (NCD-2256) Chapter 12 SPECIFICATIONS 1 2 - 4 G E N E RA L S P E C IFI C A TI O N S (1) Class of Emission P0N (2) Display Color Raster Scan (3)Display capability WVGA (800x480dots) Screen (4) Screen 7-inch Color LCD with touch sensor (resistance film type) (5) Range Scale 0.0625, 0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24, 48NM (48 NM: only 2feet type scanner is available) User can add 1, 2, 4, 8, 16, and 32NM (32 NM: only 2feet type scanner is available) (6) Range Resolution Less than 30m (7) Minimum Detective Range Less than 40m (8) Range Accuracy Less than 1% of the maximum distance of the range scale in use or less than 15m whichever is greater. (9) Bearing Accuracy Less than ±1° (10) Bearing Indication RM: Head-up, North-up, Course-up TM: North-up, Course-up (11) Ambient Condition Standards IEC60945 Ed.4.0 Temperature Scanner Operation: -25 to +55°C / Storage: -25 to +70°C Other Unit except Scanner Operation: -15 to +55°C / Storage: -15 to +70°C Relative Humidity +40°C, 93% Vibration 2 to 13.2 Hz, amplitude±1mm 13.2 to 100 Hz 0.7 G Velocity of the wind 100kn Waterproof/dustproof Scanner IP26 Display unit IP55 (12) Power Supply Input DC 10.8-31.2V (DC12-24V-10%+30%) (13) Power Consumption Approx. 50W (NKE-1066/NKE-2044). Maximum: 50W (NKE-1066: SP1, NKE-2044: LP2 transmitting) (14) Pre heat time Approx. within 1min30sec. (15) Display unit Refer to Display unit Specifications (16)Inter-unit Cables Using common scanner connecting cable CFQ-9924-10 Standard Length 10m Maximum cable length 30m 165 Chapter 12 SPECIFICATIONS 1 2 - 5 S C A NN E R 12-5-1 SCANNER (NKE-1066) SPECIFICATION (1) Dimensions Height 231mm×Diameter of radome 450mm (2) Mass Approx. 5.5kg (3) Polarization Horizontal (antenna length 1.5 feet) (4) Antenna Directivity Horizontal Beam Width (-3dB) 5.2° Vertical Beam Width (-3dB) 25° Side lobe Level Less than -21dB (less than ±10° from the main lobe) (5) Rotation Approx. 27rpm (16/27/36/48rpm are available) (6) Transmitting Frequency 9410±30MHz (7) Peak Power 4 kW (8)Transmitting Tube Magnetron [M1624] (9) Pulse width/ Repetition Frequency (Bandwidth) SP1: 0.08µs/4000 Hz (Wide 20MHz) SP2: 0.08µs/2250 Hz (Wide 20MHz) SP3: 0.13µs/1700 Hz (Wide 20MHz) MP1: 0.25µs/1700 Hz (Middle 6MHz) MP2: 0.5µs/1200 Hz (Narrow 3MHz) LP1: 0.8µs/750 Hz (Narrow3 MHz) (S: Short pulse, M: Middle pulse, L: Long pulse) (10) Range Information (11) Duplexer 0.0625NM SP1 0.125NM SP1 0.25 NM SP1 0.5 NM SP1 / MP1 0.75 NM SP2 / MP1 1.5 NM SP2 / MP1 / MP2 3 NM SP3 / MP1 / MP2 6 NM MP2 / LP1 12 NM MP2 / LP1 24 NM LP1 Circulator + Diode Limiter (Diode Limiter is included in the frontend) 166 (12) Front End Module MIC (13) IF Frequency 60MHz (14) IF AMP Log Amplifier (Gain: more than 90dB) (15) Overall Noise Figure 6dB(Average) (16) Tuning Manual/Auto Chapter 12 SPECIFICATIONS 12-5-2 SCANNER (NKE-2044) SPECIFICATION (1) Dimensions Height 280mm×Diameter of radome 620mm (2) Mass Approx. 10.5kg (3) Polarization Horizontal (antenna length 2 feet) (4) Directional Characteristic Horizontal Beam Width (-3dB) 4° Vertical Beam Width (-3dB) 25° Side lobe Level -21dB or less (less than ±10° from the main lobe) (5) Rotation Approx. 27rpm (16/27/36/48rpm are available) (6) Transmitting Frequency 9410±30MHz (7) Peak Power 4 kW (8)Transmitting Tube Magnetron [MSF1421B] (9) Pulse width/ Repetition Frequency (Bandwidth) SP1: 0.08µs/4000 Hz (Wide 20MHz) SP2: 0.08µs/2250 Hz (Wide 20MHz) SP3: 0.13µs/1700 Hz (Wide 20MHz) MP1: 0.25µs/1700 Hz (Middle 6MHz) MP2: 0.5µs/1200 Hz (Narrow 3MHz) LP1: 0.8µs/750 Hz (Narrow3 MHz) LP2:1.0us/650Hz (Narrow:3MHZ) (S: Short pulse, M: Middle pulse, L: Long pulse) (10) Range Information 0.0625NM SP1 0.125NM SP1 0.25 NM SP1 0.5 NM SP1 / MP1 0.75 NM SP2 / MP1 1.5 NM SP2 / MP1 / MP2 3 NM SP3 / MP1 / MP2 6 NM MP2 / LP1/ LP2 12 NM MP2 / LP1/ LP2 24 NM LP2 48 NM LP2 (11) Duplexer Circulator + Diode Limiter (12) Front End Module MIC (13) IF Frequency 60MHz (14) IF AMP Log Amplifier (Gain: more than 90dB) (15) Overall Noise Figure 6dB(Average) (16) Tuning Manual/Auto 167 Chapter 12 SPECIFICATIONS 1 2 - 6 DI S P L A Y 12-6-1 INTEGRATED DISPLAY UNIT (NCD-2256) 1) Structure Desk Top Integrated Type (LCD Monitor Unit/Keyboard Unit/Processor Unit Integrated Structure) Vertical installation only desk top integrated type Option: Overhead Mounted kit installation 2) Dimensions Height 235.2mm × Width 162mm × Depth 77.3mm (The U style mount base and the both sides knob bolts are included.) 3) Mass Approx. 1.8kg 4) Tune Method Manual / Auto (Bar-graph indication is displayed at the time of adjustment.) 5) STC (SEA) Manual / Auto 6) FTC (RAIN) Manual / Auto 7) Radar Interference Rejection Built-in (The effect can be adjusted by three stages.) 8) Bearing Marker 360° in 5° digit 9) Heading Line Electronic 10) Off Center move to the defined coordinates of 4 patterns (4 patterns are back side 64dots,left side 92dots, front side 92dots, right side 92dots from the default center position) Transition of the radar trails is possible during Off Center mode. 11) True Motion Unit Built-in (Not available at the maximum range) 12) True Motion Reset Position 40% of radius of any range 13) Radar trail indication True motion mode: Only true motion trails Relative motion mode: Only relative motion trails Trail time length: 15 sec to 15 min/Continuous 30 sec to 30 min/Continuous 1 min to 1 hr/Continuous 30 min to 12 hr/Continuous Arbitrary trail time length can be displayed at any time. Possible to display time series trail and continuous trail by color classification. * When switching to true/relative trails, the radar trails are cleared. Transition of the trails is possible during Off Center mode (Relative motion). (Scroll) When the bearing mode is switched (RM (T), TM), the radar trails are taken over at between RM (T) and TM. 168 Chapter 12 SPECIFICATIONS 14) Variety of Pulse width SP1/ SP2/ SP3/ MP1/ MP2/ LP1/ LP2 (LP2 is JMA-1034 only) 15) Target enhance 3 stages 16) Plotting 3 marks 17) Display color Radar echo 16 stages, 8 colors (Yellow, Green, Blue, White, Magenta, Gold, Amber, Color) Radar trails 1 stage, Time trails: 3 colors (Green, Blue, Cyan) Continuous trails: 3 colors (Green, Blue, Cyan) Background PPI: 3 colors (Black, Blue, White) Characters 7 colors (White, Cyan, Green, Black, Red, Gold, Amber) AIS/TT 3 colors (Cyan, Green, White) EBL/VRM 4 colors (Cyan, Black, Magenta, White) Cursor 4 colors (White, Red, Magenta, Yellow) Own Ship's 6 colors (Cyan, Green, Red, White, Gold, Amber) Range Ring 6 colors (Cyan, Green, Red, White, Gold, Amber) Alarm Zone 5 colors (White, Green, Orange, Black, Red) 18) Simulator Built-in 19) Multiple languages English, Spanish, Turkish, Indonesian, Thai, Malay, Vietnamese, Chinese, Russian, Korean, Japanese, Other optional language 20) Range Unit NM, Km, sm 21) Navigation information during STBY Built-in 22) AIS information display (MMSI, ship name) List display, WPT setting, Can display ship name only 169 Chapter 12 SPECIFICATIONS 12-6-2 OPERATIONAL PANEL 1) Structure Integrated on the display unit PWR/CLR 2) Key Short push: Power ON ( at the time of Power OFF) Long push: Power OFF PWR/CLR 3) Knob Controller Short push: input cancel, back to a up-layer PUSH : Menu or Icon selection and execution, control EBL/VRM, number input, Enter, etc. PUSH + rotation: Brilliance control 4) Touch control Tap: Menu or Icon selection and execution, control, etc. Double tap: Brilliance menu Icon Double tap: EBL/VRM disappear Icon Long tap: Entry of short cut Icon 12-6-3 AIS FUNCTION (STANDARD BUILT IN) 1) Display Number of targets Up to 50 targets (stores up to 500 ship static data) Target information Displays MMSI, call sign, ship name, COG, SOG, CPA, TCPA, direction, distance, latitude, longitude, status, etc. Filters Distance only Active targets Not available Dangerous ship targets No CPA/TCPA decision 2) Operation Built-in 12-6-4 TT FUNCTION (STANDARD BUILT IN) 1) Acquisition MANUAL/AUTO (by automatic acquisition/activation zone) 2) Tracking 10 targets (Automatic tracking) 3) Display Tracking data 1 ship (AIS or TT) Maximum tracking range 20NM (This varies depending on the range) Target information Displays items selected from true bearing, distance, true course, true speed, CPA, TCPA. Display of Vectors 4) Operation 170 True/Relative Built-in Chapter 12 SPECIFICATIONS 1 2 - 7 IN P U T/ O U T PU T SI G N AL Telecommunications standard NMEA0183 / 61162 -1/2 Communications protocol 4800 bps, start 1bit, data 8bit, stop 1bit, non parity Input sentence NMEA0183: V1,5: GGA/ GLL/ RMC V2,0: GGA/G LL/ RMC/ZDA V2,3 : GGA/GLL/RMC/GNS/ZDA (Talker=”GP” etc.) Information classification position and time GGA/G NS/G LL/RMC date ZDA/RMC Time ZDA/GGA/GNS/GLL/RMC 12-7-1 INPUT ENABLE SIGNAL (Three-port input GPS/HDG/AIS) (1) Navigation equipment IEC61162-1/2(※1) L/L: GGA>RMC>RMA>GNS>GLL SOG/COG: RMC>RMA>VTG Log speed: VBW>VHW HEADING: THS>HDT>HDG>HDM DEPTH: DPT>DBT WATER TEMP: MTW ROT: ROT RUDDER: RSA AIS: VDM, VDO, ALR WIND: MWV>VWT, VWR WAYPOINT: WPL (2) Bearing signal JRC-NSK format (JLR-10/20/30)(by NMEA3 port) IEC61162-1/2(※1) 4800bps/38400bps: THS>HDT>HDG>HDM (3) Speed signal IEC61162 4800bps: VBW, VHW ※1:IEC61162-2 Conformity is unnecessary. (Insulation is unnecessary. Input electrical tests are unnecessary.) 171 Chapter 12 SPECIFICATIONS 12-7-2 OUTPUT POSSIBLE SIGNAL (THREE-LINE GPS/HDG/TTM) (1) Navigation equipment Radar date: RSD Own ship’s data: OSD TT data: TTM, TTL, TTD Latitude/ Longitude data: GGA, RMC, GNS, GLL, COG/SOG: VTG (Received GPS data) Bearing signal: THS, HDT (Received GPS Compass data) (2) External Buzzer Factory presetting: normal open contacts (3) Output RGB signal To incorporate optional kit (NQA-2447) is necessary ※In this case, waterproofing (IPx5) of rear side of display unit is not guaranteed (4) Slave display no function (5) LAN no function 12-7-3 STANDARD CONFIGURATION Scanner: 1unit Display Unit: 1unit Sun cover: 1unit Scanner cable: 1pc. (10m) Power cable: 1pc. (2m) Standard included accessories: 1set (2 pieces. fuse) Instruction /Installation/Quick manual: 1 book 12-7-4 OPTION CABLE Scanner cable: 5m, 15m, 20m,30m NMEA cable (waterproof (IPx5)): 1m 172 Chapter 13 APPENDIX Chapter 13 APPENDIX NKE-1066(1.5FT) SCANNER INTRCONNECTION DIAGRAM FIG A1 APPENDIX-1 Chapter 13 APPENDIX NKE-2044(2FT) SCANNER INTRCONNECTION DIAGRAM FIG A2 APPENDIX-2 Chapter 13 APPENDIX NCD-2256 DISPLAY UNIT INTER CONNECTION DIAGRAM FIG A3 APPENDIX-3 Chapter 13 APPENDIX JMA-1030 PRIMARY POWER SUPPLY DIAGRAM FIG A4 APPENDIX-4 Chapter 13 APPENDIX JMA-1030 INTER CONNECTION DIAGRAM FIG A5 APPENDIX-5 Chapter 13 APPENDIX 90mm 140 mm FIG A6 APPENDIX-6 Chapter 13 APPENDIX O P E RA TI O N S H E E T 90mm GAIN RAIN SEA VRM GURDZONE MARK CURSOR SETTING MENU TT ACTIV TT ST-BY DAY 140 mm AIS ACTIV USER1 NIGHT TX-STBY AIS SLEEP USER2 MODE RIVER RANGE MOB BRILLIANCE EBL OFFCENTER MODE STANDARD MODE COAST MODE FIOAT MODE OFF FIG A7 APPENDIX-7 MENU FUNCTION LIST M EN U F U NC TI O N LI S T Main Menu Item Setting Contents 1. RADAR Echo 1. Pulse Length SP/MP/LP 2. IR OFF / Low / Middle / High 3. Target Enhance OFF / Level1 / Level2 / Level3 4. Process OFF / 3Scan COREL / 4Scan COREL / 5Scan COREL / Remain / Peak Hold 5. Zoom OFF / ON 6. Video Latitude Narrow / Normal / Wide1 / Wide2 7. Video Noise Rejection OFF / Level1 / Level2 / Level3 8. Timed TX OFF / ON 2. Tuning 3. Motion Mode 1. Motion RM, TM 2. Bearing Mode HUP/NUP/CUP 4. Radar trail 1. Trails REF Level Level1 / Level2 / Level3 / Level4 2. Time/All Combine OFF / ON 3. Trails Mode True/Relative 4. Trails Interval OFF/15sec/30sec/1min/2min/3min/4min/5min/6min/10min/15min/CONT 5. Vector Length 1. Vector Mode True/Relative 2. Vector Length 1 - 60min 6. Maker 1. Maker Mode True/Relative 2. VRM Unit NM/km/sm 3. EBL Bearing Mode Heading Fix / Screen Fix 4. Range Rings(RR) OFF / ON 7. Target 1. Function ON/OFF 1. TT OFF / ON 2. AIS OFF / ON 2. CPA Limit 0.1 - 9.9NM 3. TCPA Limit 1 - 99min APPENDIX-8 MENU FUNCTION LIST Item Setting Contents 4. CPA Ring Display OFF / ON 5. Target Number Display 1. TT OFF / ON 2. AIS OFF / ON 6. ALR Alarm From AIS OFF / ON 7. AIS Display Targets 20 / 30 / 40 / 50 8. AIS List Display OFF / ON 8. NMEA Info. Set APPENDIX-9 MENU FUNCTION LIST Initial setting Menu Item 1. Basic Adjustment 1. Bearing Adjustment 2. Range Adjustment 3. Tune Adjustment 4. Antenna Height 5. Noise Level 6. Language 2. RADAR Echo 1. Main Bang Suppression 1. MBS Level 2. MBS Area 2. Target Enhance Level 3. Gain Preset 4. STC 1. STC Curve Select 2. STC Slope Correction 3. STC Offset 1. FTC 1. FTC Curve Select 2. FTC Slope Correction 3. FTC Offset 6. RADAR Alarm 1. RADAR Alarm1 Level 2. RADAR Alarm2 Level Setting Contents 0.0 - 359.9 0 - 999 0 - 127 ~5m/5~10m/10~20m/20m~ 0 - 255 English/Spanish/Turkish/Indonesian/Thai/Malay/Vietnamese/ Chinese/Japanese/Korean/Russian 0 - 255 0 - 255 Level1/Level2/Level3/Level4 0 - 255 Sea/River 0.0 - 2.0 0 - FF Sea/River 0.0 - 2.0 0 - FF Level1/Level2/Level3/Level4 Level1/Level2/Level3/Level4 3. RADAR Trails 1. MAX Interval 2. Suppression Distance Short/Middle/Long/Super Long 0 - 1000 4. TT 1. Vector Constant 2. Gate Display 3. Gate Size 1-8 OFF / ON 0 - 64 5. Scanner 1. PRF Fine Tuning 2. Stagger Trigger 3. Antenna Rotation Speed 1. SP1 2. SP2 3. SP3 4. MP1 5. MP2 6. LP1 7. LP2 (*NKE-2044 only) 4. PRF Mode 5. Timed TX 1. TX Time 2. STBY Time 3. Adaptation 6. Tune Peak Adjustment 7. Tune Indicator Level 6. I/F Device 1. Heading Equipment 2. Manual Heading 3. Speed Equipment 4. Manual Speed 5. MAG Compass Setting 1. Heading Correction 2. Correct Value APPENDIX-10 0 - 31 OFF / ON 0-7 0-7 0-7 0-7 0-7 0-7 0-7 Normal/Economy/High Power 1 - 99 1 - 99 ON/OFF 0 – 127 0 - 127 AUTO/GYRO/Compass/GPS/Manual 0.0 - 359.9 GPS/Log/2axis Log/Manual 0.0 - 100.0kn OFF / ON W9.9 - E9.9° MENU FUNCTION LIST Item Setting Contents 7. COM Port Setting 1. Baud Rate 1. NMEA1 2. NMEA2 3. NMEA3 2. RX Port 1. GPS 2. Log 3. 2axis Log 4. Depth 5. Temperature 6. Wind 7. WPT 8.Rate of Turn 9. Rudder 3. TX Port 1. TTM 2. TLL 3. TTD 4. TLB 5. GGA 6. GLL 7. RMC 8. GNS 9. VTG 10. THS 11. HDT 12. OSD 13. RSD 4. TX Data Format 1. TX Interval 2. NMEA Version 3. NMEA Talker 5. Target Info. TX 1. TX Target 2. TTM Range Accuracy 3. TT Average Mode 4. TT Average Scan AUTO/4800bps/38400bps AUTO/4800bps/38400bps AUTO/4800bps/38400bps AUTO/NMEA1/NMEA2/NMEA3 AUTO/NMEA1/NMEA2/NMEA3 AUTO/NMEA1/NMEA2/NMEA3 AUTO/NMEA1/NMEA2/NMEA3 AUTO/NMEA1/NMEA2/NMEA3 AUTO/NMEA1/NMEA2/NMEA3 AUTO/NMEA1/NMEA2/NMEA3 AUTO/NMEA1/NMEA2/NMEA3 AUTO/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 OFF/NMEA1/NMEA2/NMEA3 1 - 9sec V1.5/V2.0/V2.3 Normal/GP TT/AIS/TT-AIS 1/2/3 OFF / ON 2 - 10 8. JRC GPS 1. GPS Status 2. GPS Setting 1. NMEA Version 2. Correction Method 3. Fix Mode 4. Elevate Mask 5. HDOP 6. Smoothing LL 7. Smoothing SOG 8. Smoothing COG AUTO/V1.5/V2.0/V2.3 GPS Single/SBAS/Beacon/AUTO 2D/3D/AUTO 5 - 89° 4/10/20 0 - 99sec 0 - 99sec 0 - 99sec 0 - 99sec (R29.04 - R33.99) 1 - 99sec (R26.01 - R29.03) 0sec/10sec/40sec OFF/10/30/50/100m 9. Smoothing 10. Smoothing 11. RAIM Accuracy Level 12. Exclusion Satellite 1. Exclusion Satellite1 2. Exclusion Satellite2 3. Exclusion Satellite3 4. Exclusion Satellite4 5. Exclusion Satellite5 6. Exclusion Satellite6 0 - 32 0 - 32 0 - 32 0 - 32 0 - 32 0 - 32 APPENDIX-11 MENU FUNCTION LIST Item Setting Contents 13. Send Data 14. GPS Adjust 1. Position 2. Antenna Height 3. Time 4. Date 5. Master Reset 6. Send Data 3. Beacon Setting 1. Station Select 2. Frequency 3. Baud Rate 4. Send Data 4. SBAS Setting 1. Satellite Search 2. Ranging 3. SBAS Satellite Number 4. Send Data 9. Control 1. Touch Panel Calibration 2. Bearing Reference (*NKE-2044 only) 3. Buzzer 1. Key ACK 2. Operation Error 3. CPA/TCPA 4. AZ/Alarm Zone 5. Target Lost 6. System Alarm 10. Maintenance 1. Partial Reset 1. All Menu 2. RADAR Echo 3. Function Setting 4. Initial Setting Menu 5. Main Menu 6. Adjust Menu (*NKE-2044 only) 7. System Information 1 (*NKE-2044 only) 8. System Information 2 (*NKE-2044 only) 2. All Reset 3. System Time Clear 4. Scanner Time Clear 1. TX Time Clear 2. Motor Time Clear 3. ANT to DISP Unit 4. DISP to ANT Unit 5. Table Update 1. Initial Value 1. All Menu 2. RADAR Echo 3. Function Setting 4. Initial Setting Menu 5. Main Menu 6. Adjust Menu (*NKE-2044 only) 7. System Information 1 (*NKE-2044 only) 8. System Information 2 (*NKE-2044 only) 2. Insert Language 3. Echo Simulation (*NKE-2044 only) 4. STC Curve 5. Color Pallet (*NKE-2044 only) APPENDIX-12 0 - 8191m 00:00:00 - 23:59:59 2013/1/1/ - 2099/12/31 AUTO/Manual 283.5 - 325.0kHz 50 / 100 / 200bps AUTO/Manual OFF / ON 120 - 138 True/Relative OFF/1 - 5 OFF/1 - 5 OFF/1 - 5 OFF/1 - 5 OFF/1 - 5 OFF/1 – 5 MENU FUNCTION LIST Item Setting Contents 6. Internal Setting 1. Internal Memory to USB 1. All Menu 2. RADAR Echo 3. Function Setting 4. Initial Setting Menu 5. Main Menu 6. Mark Setting 7. Adjust Menu (*NKE-2044 only) 8. System Information 1 (*NKE-2044 only) 9. System Information 2 (*NKE-2044 only) 2. USB to Internal Memory 1.All Menu 2. RADAR Echo 3. Function Setting 4. Initial Setting Menu 5. Main Menu 6. Mark Setting 7. Adjust Menu (*NKE-2044 only) 8. System Information 1 (*NKE-2044 only) 9. System Information 2 (*NKE-2044 only) 7. USB Format 11. System Setting 1. Master/Slave/DEMO 2. Own Ship Outline 1. All Length 2. All Width 3. Scanner (from Bow) 4. Scanner (from Cntr.) 3. Unit 1. Range 2. Distance 3. Speed 4. Depth 5. User Depth 6. Temperature 7. Wind 4. Move Own Ship 1. Ship's Move Method 5. Range 1. NM Master/Slave/Demo 0.0 - 600.0m 0.0 - 200.0m 0.0 - 600.0m -100.0 – 100.0m NM/km/sm NM/km/sm kn/ km/h /mph ft/fm/m/user 0.1 - 10.0 °C /°F m/s / km/h / kn / Bft. LL / COG/SOG 1. 0.0625NM 2. 0.125NM 3. 0.25NM 4. 0.5NM (*NKE-2044 only) 5. 0.75NM (*NKE-2044 only) 4. 1NM 5. 2NM 6. 4NM 7. 8NM 8. 16NM 9. 24NM 10. 32NM 11. 48NM OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON APPENDIX-13 MENU FUNCTION LIST Item Setting Contents 2. km 1. 0.15km 2. 0.3km 3. 0.5km (*NKE-2044 only) 4. 1.2km 5. 2km 6. 8km 7. 16km 8. 32km OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON 1. 0.0625sm 2. 0.125sm 3. 0.25sm 4. 1sm 5. 2sm 6. 4sm 7. 8sm 8. 16sm 9. 24sm 10. 32sm 11. 48sm OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON OFF / ON 3. sm 12. Display Screen 1. Own Vector Display 2. STBY Disp. Select 3. Operation Num Disp. 4. Display Color 1. PPI 1. Color 2. Brilliance 2. Inner PPI (*NKE-2044 only) 1. Color (*NKE-2044 only) 2. Brilliance (*NKE-2044 only) 3. Character 1. Color 2. Brilliance 4. RADAR Echo 1. Color 2. Brilliance 5. RADAR Trails (Time) 1. Color 2. Brilliance 6. RADAR Trails (All) 1. Color 2. Brilliance 7. Own Ship's 1. Color 2. Brilliance 8. Target (TT/AIS) 1. Color 2. Brilliance 9. EBL/VRM 1. Color 2. Brilliance 10. Range Ring 1. Color 2. Brilliance 11. Cursor 1. Color 2. Brilliance APPENDIX-14 OFF / ON Normal / Graphical / Numeric Display OFF / ON Black/ Blue/ White Level1/ Level2/ Level3/ Level4 Black/ Blue/ White Level1/ Level2/ Level3/ Level4 White/Cyan/Green/Black/Red/Gold/Amber Level1/ Level2/ Level3/ Level4 Yellow/Green/Blue/White/Magenta/Gold/Amber/Color Level1/ Level2/ Level3/ Level4 Green/Blue/Cyan Level1/ Level2/ Level3/ Level4 Green/Blue/Cyan Level1/ Level2/ Level3/ Level4 Cyan/Green/Red/White/Gold/Amber Level1/ Level2/ Level3/ Level4 Cyan/Green/White Level1/ Level2/ Level3/ Level4 Cyan/Black/Magenta/White Level1/ Level2/ Level3/ Level4 Cyan/Green/Red/White/Gold/Amber Level1/ Level2/ Level3/ Level4 White/Red/Magenta/Yellow Level1/ Level2/ Level3/ Level4 MENU FUNCTION LIST Item Setting Contents 12. AZ/Alarm Zone 1. Color 2. Brilliance White/Green/Orange/Black/Red Level1/ Level2/ Level3/ Level4 ON/OFF 0.0 - 48.0 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 - 999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 – 999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 - 999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 - 999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 3. Connection Device (*NKE-2044 only) 1. GYRO(Time Out) (*NKE-2044 only) 1. Alarm Sensitivity (*NKE-2044 only) 2. Sensitivity Time (*NKE-2044 only) 2. Log(Time Out) (*NKE-2044 only) 1. Alarm Sensitivity (*NKE-2044 only) 2. Sensitivity Time (*NKE-2044 only) 3. GPS(Time Out) (*NKE-2044 only) 1. Alarm Sensitivity (*NKE-2044 only) 2. Sensitivity Time (*NKE-2044 only) OFF / ON 5. Waypoint Display 6. AIS Filter 13. Error Alarm Mask 1. Scanner 1. Scanner(Time Out) 2. Scanner(Data) 3. Scanner(Video) 4. Scanner (Trigger) 5. Scanner(AZI) 6. Scanner(HL) 7. Scanner(MHV) 8. Scanner(Heater) 2. Display Unit 1. Display Unit(Video) 2. Display Unit(Trigger) 3. Display Unit(AZI) 4. Display Unit(HL) 5. Display Unit(DSP) 6. COM Port OFF / ON 0 -999sec OFF / ON 0 -999sec OFF / ON 0 -999sec APPENDIX-15 MENU FUNCTION LIST Item Setting Contents 4. RX Data 1. GYRO 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Alarm Sensitivity 2. Sensitivity Time OFF / ON 0 -999sec 1. Indicator Software 2. Boot 3. DSP (MC) 4. DSP (V) 5. Test Bench 6. Scanner Software 7. Update 1.0.0 01.06 01.00.00.00 01.00.00.00 01.04 04.02 01.06 2. Compass 3. Log 4. 2Axis Log 5. Course/Speed 6. Depth 7. Temperature 8. Wind 9. Rate of Turn 10. Rudder 11. WPT 12. LAT/LON 13. Datum 14. Status 15. HDOP 16. AIS 14. Test 1. System Information APPENDIX-16 MENU FUNCTION LIST Item Setting Contents 2. System Time 1. Scanner Transmit Time 2. Scanner Motor Time 3. Scanner Running Time 4. Indicator Running Time 3. Scanner Information 1. Scanner Transmit Power 2. Motor Type 3. Magnetron Current 4. Hardware Information 1. Serial Number 2. MAC Address 5. Error Log 1. Display 2. Erase 6. Line Monitor 1. Scanner 2. NMEA1 3. NMEA2 4. NMEA3 7. Self Test 1. Key Test 2. Touch Panel Test 3. Buzzer Test 4. Key Light Test 5. Monitor Display Test Pattern1 Pattern2 Pattern3 Pattern4 Pattern5 Pattern6 Pattern7 RGB Setting Red Green Blue Display 6. Memory Test 1. SDRAM 2. Flash ROM 3. USB 7. Line Test 1. Scanner 2. NMEA1 or GPS(JRC) 3. NMEA2 4. NMEA3 or NSK 8. Scanner Test 1. SSW Off 2. BP 3. BZ 4. Mod.HV 5. Trigger 6. Video APPENDIX-17 MENU FUNCTION LIST APPENDIX-18 Not use the asbestos JRC website http://www.jrc.co.jp/ Marine Service Department Telephone: +81-3-3492-1305 Facsimile: +81-3-3379-1420 e-mail tmsc@.jrc.co.jp Amsterdam branch Telephone: +31-(0)20-658-0750 Facsimile +31-(0)20-658-0755 e-mail service@jrceurope.com Seattle branch Telephone: +1-(0)206-654-5644 Facsimile: +1-(0)206-654-7030 e-mail service@jrcamerica.com 01JTM ISO 9001 and ISO 14001 Certified Code No.7ZPRD0895 Dec, 2013 creation The 1st edition JRC
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Create Date : 2014:01:06 13:55:43-08:00 Creator : CubePDF Modify Date : 2014:01:06 15:36:10-08:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:01:06 15:36:10-08:00 Creator Tool : CubePDF Format : application/pdf Document ID : uuid:bb7a5245-e377-424a-bc14-6c7c270a69e2 Instance ID : uuid:d86d102c-f0ef-4b82-a738-c293568fcf56 Producer : GPL Ghostscript 9.07; modified using iTextSharp™ 5.4.2 ©2000-2012 1T3XT BVBA (AGPL-version) Page Count : 57EXIF Metadata provided by EXIF.tools