Jasco OAMTX Digital Wireless Thermometer(433MHz Transmitter) User Manual 103 M3

Jasco Products Company Digital Wireless Thermometer(433MHz Transmitter) 103 M3

User Manual

Download: Jasco OAMTX Digital Wireless Thermometer(433MHz Transmitter) User Manual 103 M3
Mirror Download [FCC.gov]Jasco OAMTX Digital Wireless Thermometer(433MHz Transmitter) User Manual 103 M3
Document ID342934
Application IDlhSUrJ8aQLZSQyLgDPGqcw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize17.02kB (212749 bits)
Date Submitted2003-07-25 00:00:00
Date Available2003-07-25 00:00:00
Creation Date2003-05-22 15:13:44
Producing SoftwareAcrobat Distiller 4.05 for Macintosh
Document Lastmod2003-06-25 16:09:31
Document Title103-M3
Document CreatorAdobe PageMaker 6.52
Document Author: LCD-eMac

MULTI-CHANNEL CABLE FREE
IN-OUT THERMOMTER
ENGLISH
MODEL: GE5805WS4
USER'S MANUAL
INTRODUCTION
SPECIFICATIONS
Fig.1
The GE5805WS4 is very easy to use. No wire installation is required between
the main unit and the remote units.
Designated
Display
A.
OUTDOOR TEMPERATURE
Shows the temperature of the selected remote channel
B.
INDOOR TEMPERATURE
Shows the temperature taken indoor
C.
D.
E.
Fig.2
Remote
Display
Channel One
Remote
Display
Channel Two
Remote
Display
Channel Three
[MAX/MIN] BUTTON
Displays current, maximum or minimum temperature
F.
RESET BUTTON
Returns all settings to default values
G.
BATTERY COMPARTMENT
Accommodates two (2) UM-3 or “AA” size 1.5V batteries
H.
°C/°F SLIDE SWITCH
Selects between degrees Centigrade (C) and Fahrenheit (F)
I.
TABLE STAND
Rotates out to support the unit on a flat surface
J.
WALL-MOUNT HOLE
For mounting the unit on a wall
LED INDICATOR
Flashes when the remote unit transmits a reading
Fig.3
-20.0°C to +60.0°C (-4.0°F to 140.0°F)
0.1°C (0.2°F)
433 MHz
The maximum and minimum recorded indoor temperatures and those of each
channel will be automatically stored in memory.
RF Transmission Range
30 meters (open area)
Temperature sensing cycle
around 30 seconds
Main unit
use 2 pcs UM-3 or ”AA” 1.5V battery
Remote sensing unit
use 2 pcs UM-3 or “AA” 1.5V battery
To display them,
1.
Press [CH] to locate the desired channel.
2.
Press [MAX/MIN] repeatedly to display the current, maximum (MAX)
and minimum (MIN) temperatures. The readings of the indoor
temperatures will also be displayed.
Power
Weight
To clear the memory of a particular channel,
Main unit
TBC g (without battery)
1.
Press [CH] to locate the desired channel.
Remote sensing unit
TBC g (without battery)
2.
Press [CLEAR]. Note it will also erase the memory for the indoor
temperatures. If you press [MAX/MIN] now, the maximum and minimum
temperatures will have the same values as the current ones until different
readings are recorded.
Main unit
66.5 x 74 x 30 mm (L x W x T)
Remote sensing unit
80 x 70 x 33.5 mm (L x W x T)
Dimension
ICE WARNING FUNCTION
NOTE ON COMPLIANCE
The GE5805WS4 includes an ice warning function. This feature is built into
remote sensor CHANNEL 1 functions.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including interference
that may cause undesired operations.
When the temperature recorded at CHANNEL 1 falls to between -2°C (28.4°F)
to +3°C (37.4°F) the current outdoor temperature will flash.
TO DEACTIVATE THIS FUNCTION, SET THE REMOTE SENSOR TO
CHANNEL 2 or CHANNEL 3.
Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment.
FCC :
DISCONNECTED SIGNALS
If without obvious reasons the display for a particular channel goes blank,
press [CH] and [MAX/MIN] to enforce an immediate search. If that fails,
check if the remote unit of that channel is still in place. Make sure the
transmission is within range and path is clear of obstacles and interference. No
reading will be shown if no remote unit is assigned to that channel.
C.
RESET BUTTON
D.
BATTERY COMPARTMENT
LOW BATTERY WARNING
Accommodates two (2) UM-3 or “AA” size 1.5V batteries
E.
BATTERY DOOR
When it is time to replace batteries, the respective low-battery indicator will
show up when the respective channel is selected. The battery level of the main
unit will be shown on the indoor temperature when it is running low.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
■
Reorient or relocate the receiving antenna.
■
Increase the separation between the equipment and receiver.
HOW TO USE THE TABLE STAND OR WALL
MOUNTING (Fig. 5)
■
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer of an experienced radio/TV technician for help.
•
Assign different channels to different remote units.
•
Insert batteries for remote units before doing so for the main unit.
Set the main and remote units within range (20 to 30 meters).
Flip the table stand out to place the main unit on a flat surface. Or you can hide
the stand and mount the unit on a wall using the recessed hole.
■
•
•
Try different set-ups for best transmission and reception.
As for the remote unit, mount the unit on a wall using the recessed hole.
•
Position the remote units away from direct sunlight, rain or snow.
Company Name: GE Wiring Devices & Specialty Products, Inc.
(d/b/a GE Home Electric Products, Inc.)
THE RESET BUTTON
Address: 1975 Noble Rd, Cleveland, OH 44112 USA
BATTERY AND CHANNEL INSTALLATION:
REMOTE UNIT (Fig. 3)
The [RESET] button is used to enhance synchronization of signals after battery
replacement or when the unit is operating in an unfavorable way or
malfunctioning. Use a blunt stylus to hold down the button. All settings will
return to their default values.
1.
Remove the screws on the battery compartment.
2.
Select the channel number on the CHANNEL slide switch.
3.
Install 2 batteries (UM-3 or “AA” size 1.5V) strictly according to the
polarities shown.
MAINTENANCE
4.
Replace the battery compartment door and secure its screws.
When handled properly, this unit is engineered to give you years of satisfactory
service. Here are a few product care instructions:
Note that once a channel is assigned to a remote unit, you can only change it by
removing the batteries or resetting the unit.
Fig.5
Proposed operating range
Temperature resolution
Maximum of 3
Returns all settings to default values
Fig.4
Remote unit
CHANNEL SLIDE SWITCH
HINTS FOR BEST OPERATION
0.1°C (0.2°F)
No. of Remote unit
B.
Designates the remote unit Channel 1, Channel 2 or Channel 3
-5.0°C to +50.0°C (23.0°F to 122.0°F)
MAXIMUM AND MINIMUM TEMPERATURES
MAIN FEATURES: REMOTE UNIT (Fig. 2)
A.
Temperature resolution
RF Transmission Frequency :
[CH] BUTTON
Selects among different channels
[CLEAR] BUTTON
Clears the memory for the indoor temperature and that for the selected
channel
Proposed operating range
Temperature Display in °C or °F
To start an automatic scan on all channels, press and hold [CH] for two seconds.
The main unit will scan from one channel to another and back. The reading for
individual channel will be displayed for five seconds. Press any key to end the
automatic scan.
MAIN FEATURES (Fig. 1)
Main unit
Indoor Temperature measurement
Congratulations on your purchasing of the GE5805WS4 Multi-channel Cable
Free In-out Thermomter.
The basic package comes with a main unit and a remote sensor. The main unit
can support up to three remote sensors.
Temperature Measurement
Kinetic-wave
Icon
1.
Do not immerse the unit in water. If the unit comes in contact with water,
dry it immediately with a soft lint-free cloth.
2.
Do not clean the unit with abrasive or corrosive materials. Abrasive
cleaning agents may scratch the plastic parts and corrode the electronic
circuit.
BATTERY INSTALLATION: MAIN UNIT (Fig. 4)
1.
Open the battery compartment door.
2.
Insert two (2) UM-3 or “AA” size 1.5V batteries.
3.
Press RESET.
4.
Replace the battery compartment door.
GETTING STARTED
Once batteries are in place for the remote units, they will start transmitting
sampling roughly at 30-second intervals.
The main unit will also start receiving once batteries are installed. The
temperature of the selected channel will be displayed on the main display and
the indoor temperature on the secondary display. The main unit will
automatically update its readings at 30-second intervals.
If no signals are received, blanks will be displayed. Press [CH] and [MAX/
MIN] simultaneously to enforce an immediate search. This is useful in
synchronizing the transmission and reception of the remote and main units.
INDOOR AND OUTDOOR TEMPERATURES
The indoor temperature is shown on the secondary display.
As for the remote sites or channels, press [CH] repeatedly to go from one
channel to another. The kinetic wave display on the channel number indicates
the reception of that particular channel is in good order.
3.
Do not subject the unit to excessive: force, shock, dust, temperature, or
humidity. Such treatment may result in malfunction, a shorter electronic
life span, damaged batteries, or distorted parts.
4.
Do not tamper with the unit’s internal components. Doing so will terminate
the unit’s warranty and may cause damage. The unit contains no userserviceable parts.
5.
Only use new batteries as specified in this instruction manual. Do not mix
new and old batteries as the old batteries may leak.
6.
Read this instruction manual thoroughly before operating the unit.
Contact Person: Beth Eskra
Telephone Number: 216-266-3188
Name and model number of the product:
In/Out Thermo GE5805WS4
CAUTION
- The content of this manual is subject to change without further notice.
- Due to printing limitation, the displays shown in this manual may differ
from the actual display.
- The contents of this manual may not be reproduced without the
permission of the manufacturer.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 2003:05:22 15:13:44Z
Subject                         : 103-M3
Modify Date                     : 2003:06:25 16:09:31+08:00
Page Count                      : 1
Creation Date                   : 2003:05:22 15:13:44Z
Producer                        : Acrobat Distiller 4.05 for Macintosh
Keywords                        : 
Author                          : LCD-eMac
Mod Date                        : 2003:06:25 16:09:31+08:00
Metadata Date                   : 2003:06:25 16:09:31+08:00
Description                     : 103-M3
Title                           : 103-M3
Creator                         : LCD-eMac
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QOBOAMTX

Navigation menu