Instruction Manual
47-1004F, 47—1004G & 47—1004H
RE M OTE CONTROL INSTALLATION
1. Locate and connect the input and output terminals to the correct terminals.
OF M OIP az OIP es
Output 'l'emnnal $41 : 300W (Incandescent Lamp)
Output Terminal #2: 1200W(Re515tive Load)
Output Tenninal #3: lZOOW (Resistive Load)
Remark: fhe total max. output for Terminal #2 & #3 is lZOOW.
REMOTE CONTROL
The remote control has a range of approximately 50 ft. (15.25m), it does not have to be pointed the
fireplace and can pass through most obstacles (including walls), It is supplied with one of 2187
independent frequencies to prevent interference with other units, The frequency designation is
indicated on the back of the transmitter.
A. Remote Control Initialization
This procedure is required every time there is a loss of power to the remote control with the receiver.
(i.e. power failure, breaker tripped, main power switch is tumed off).
1. Ensure that power is supplied through the receiver
2. Locate manual controls (Blue,“ - "), (Grey “ + ”) and (Black “ GND ") Wires
3. Activate main power switch, red indicator light 1 will flash.
4. Press and hold the ON switch (short Grey & Black Wires) for 5 seconds. The second red
indicator“ light will flash.
5. Press ON button located on the remote control transmitter. This will synchronize the
remote control transmitter and receiver.
B. Remote Control Usage
The remote control operates the system levels sequentially. The level is increased every time the
ON button on the transmitter is pressed. The receiver can he turned off at any point by pressing the
OFF button on the remote control transmitter.
Remark: Output Terminal #1: Indicator #1 (Red Wire)
Output Terminal #2: Indicator #2 (Orange wire)
Output Terminal #3: Indicator #3 (Yellow wire)
C. Manual Control
The fireplace can also be controlled in a similar manner to the remote control with switches located
on the receiver,
1. On Switch (short Grey & Black wires)
Operates receiver in the same manner as the remote control transmitter. Pressing this
button has the same effect as the ON button on the remote control. Pressing once to the
activates Level 1, twice activates Level 2, three times activates Level 3.
2. Off Switch (short Blue & Black wires)
Pressing this button has the same effect as the OFF button on the remote control. Pressing
once to shut the unit off,
WARNING
Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
7 Reorient or relocate the receiving antenna.
7 increase the separation between the equipment and receiver,
l i Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
l, l Li Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation.
Specifications
lnput Rating .................................................................................................... AC 120V, 60m
Output Rating ....................................................................................... . AC 120V. 601-12
Resistive Load ....................................................................................................... lZOOW
incandescent Lamp ...,300w
Operation Temperature, 0 — 40“C
Storage Temperature . ., -25 - 60°C

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2006:09:28 09:46:38
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ELY547-47-1004-R

Navigation menu