Juniper Networks 200 DUAL MODE 2.4GHz / 5GHz ACCESS POINT User Manual Trapeze Mobility Point Installation Guide

Juniper Networks, Inc. DUAL MODE 2.4GHz / 5GHz ACCESS POINT Trapeze Mobility Point Installation Guide

USERS MANUAL

Download: Juniper Networks 200 DUAL MODE 2.4GHz / 5GHz ACCESS POINT User Manual Trapeze Mobility Point Installation Guide
Mirror Download [FCC.gov]Juniper Networks 200 DUAL MODE 2.4GHz / 5GHz ACCESS POINT User Manual Trapeze Mobility Point Installation Guide
Document ID527008
Application ID5eNzZkA0LjswFUj0AJ2YeA==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize74.67kB (933345 bits)
Date Submitted2005-03-28 00:00:00
Date Available2005-03-28 00:00:00
Creation Date2005-03-24 11:47:46
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2005-03-25 09:56:54
Document TitleTrapeze Mobility Point Installation Guide
Document CreatorFrameMaker 7.0
Document Author: Trapeze Networks Technical Publications

Trapeze
Mobility Point™
MP-372 Installation Guide
Part Number 730-9502-0052, Revision C
Trapeze Networks, Inc.
5753 W. Las Positas Blvd.
Pleasanton, CA 94588
Tel: +1 925-474-2200
Fax: +1 925-251-0642
Toll-Free: 877-FLY-TRPZ (877-359-8779)
www.trapezenetworks.com
© 2005 Trapeze Networks, Inc. All rights reserved.
Trademarks
Trapeze Networks, the Trapeze Networks logo, the Trapeze Networks flyer icon, Mobility System, Mobility
Exchange, MX, Mobility Point, MP, Mobility System Software, MSS, RingMaster, AAA Integration and
RADIUS Scaling, ActiveScan, AIRS, Bonded Auth, FastRoaming, Granular Transmit Power Setting, GTPS,
GuestPass, Layer 3 Path Preservation, Location Policy Rule, LPR, Mobility Domain, Mobility Profile,
Passport-Free Roaming, SentryScan, Time-of-Day Access, TDA, TAPA, Trapeze Access Point Access
Protocol, Virtual Private Group, VPG, Virtual Service Set, Virtual Site Survey and WebAAA are trademarks
of Trapeze Networks, Inc. Trapeze Networks SafetyNet is a service mark of Trapeze Networks, Inc. All other
products and services are trademarks, registered trademarks, service marks or registered service marks of their
respective owners.
Disclaimer
All statements, specifications, recommendations, and technical information are current or planned as of the
date of the publication of this document. They are reliable as of the time of this writing and are presented
without warranty of any kind, expressed or implied. In an effort to continuously improve the product and add
features, Trapeze Networks reserves the right to change any specifications contained in this document without
prior notice of any kind.
Comments and Feedback
Your feedback on Trapeze documentation is important to us. Send any comments and suggestions to
doc-bugs@trapezenetworks.com.
For the most current version of this document, see www.trapezenetworks.com.
Note. The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. Such modifications
could void the user’s authority to operate the equipment.
ii
Customer Service
For general information about Trapeze Networks Mobility System™ products and
services, visit www.trapezenetworks.com. For warranty, license, and support
information, visit the following sites:
●
Warranty and software licenses. Current Trapeze Networks warranty and
software licenses are available at www.trapezenetworks.com/services/
warranty.asp.
●
Support services. For information about Trapeze support services, visit
www.trapezenetworks.com/services/. Or call 1-866-877-9822 (in the US or
Canada) or +1 925-474-2400 and select option 5.
Note. TRAPEZE NETWORKS SELLS AND SERVICES ITS PRODUCTS PRIMARILY
THROUGH ITS AUTHORIZED RESELLERS AND DISTRIBUTORS. If you purchased
your product from an authorized Trapeze reseller or distributor and do not have
a service contract with Trapeze Networks, you must contact your local reseller
or distributor for technical assistance.
Contacting the Technical Assistance Center
Contact the Trapeze Networks Technical Assistance Center (TAC) by telephone,
email, or fax. If you have a service contract or are a Trapeze Authorized Partner,
log in to www.trapezenetworks.com/services/sup_programs.asp for more help.
●
Within the US and Canada, call 1-866-TRPZTAC (1-866-877-9822).
●
Within Europe, call +31 35 64 78 193.
●
From locations outside the US and Canada, call +1 925-474-2400.
●
In non-emergencies, send email to support@trapezenetworks.com.
●
When your case is active, you can fax more information to +1 925-474-2423.
iii
TAC Response Time
TAC responds to service requests as follows:
Contact
method
Priority
Response time
Telephone
Emergency
One hour
Non-emergency Next business day
Email
Non-emergency Next business day
Information to Have Available
To expedite your service request, have the following information available when
you call or write to TAC for technical assistance:
iv
●
Your company name and address
●
Your name, telephone number, cell phone or pager number, and email address
●
Name, model, and serial number of the product(s) requiring service
●
Software version and release number
●
Output of the show tech-support command
●
Wireless client information
●
License levels for RingMaster™ and Mobility Exchange™ (MX™) products
●
Description of the problem and status of the troubleshooting effort
Trapeze Mobility Point Installation Guide
Contents
Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
1 Introducing the Trapeze Networks Mobility System . . . . . . . . . . . . . . . . 1
Trapeze Networks Mobility System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Advisory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Text and Syntax Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 MP Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
External Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cable Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
External Antenna Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Kensington Security Slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
MP Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Connection Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3 Installing and Connecting an MP-372 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Unpacking an MP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Installation Requirements and Recommendations . . . . . . . . . . . . . . . . . . . . 18
RingMaster Network Plan and Work Orders . . . . . . . . . . . . . . . . . . . . . 18
MX Switch Recommendation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Wall Installation Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
MP Radio Safety Advisories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Radio Frequency Exposure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Additional Radio Safety Advisories . . . . . . . . . . . . . . . . . . . . . . . . 19
Cable Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Installing an MP-372 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Installation Hardware and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Suspended Ceiling Installation—Flush Ceiling Tiles . . . . . . . . . . . . . . 24
Suspended Ceiling Installation—Drop Ceiling Tiles . . . . . . . . . . . . . . . 30
Contents
Junction Box Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Solid Wall or Ceiling Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Tabletop Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Connecting an MP to an External Antenna . . . . . . . . . . . . . . . . . . . . . . 49
Connecting an MP to an MX Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Verifying MP Health . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
A MP Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
B MP Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
C Translated Warning Conventions and Warnings . . . . . . . . . . . . . . . . . . . 61
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
vi
Trapeze Mobility Point Installation Guide
1
Introducing the Trapeze
Networks Mobility System
Trapeze Networks Mobility System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
This guide shows you how to install a Trapeze Networks™ Mobility Point™
(MP™) access point in a Trapeze Networks Mobility System™ wireless LAN
(WLAN).
Read this guide if you are a network administrator or other person installing MP
access points in a network.
Trapeze Networks Mobility System
The Trapeze Networks Mobility System is an enterprise-class WLAN solution
that seamlessly integrates with an existing wired enterprise network. The Trapeze
system provides secure connectivity to both wireless and wired users in large
environments such as office buildings, hospitals, and university campuses.
The Trapeze Mobility System fulfills the three fundamental requirements of an
enterprise WLAN: It eliminates the distinction between wired and wireless
networks, allows users to work safely from anywhere (secure mobility), and
provides a comprehensive suite of intuitive tools for planning and managing the
network before and after deployment, greatly easing the operational burden on IT
resources.
Introducing the Trapeze Networks Mobility System
Documentation
Chapter 1
The Trapeze Networks Mobility System consists of the following components:
●
RingMaster tool suite—A full-featured graphical user interface (GUI) client
application used to plan, configure, and deploy a WLAN and its users. It also
provides a centralized service application for WLAN and user monitoring,
reporting, and diagnostics
●
One or more Mobility Exchange™ (MX™) switches—Distributed,
intelligent machines for managing user connectivity, connecting and
powering Mobility Point (MP) access points, and connecting the WLAN to
the wired network backbone
●
Multiple Mobility Point™ (MP™) access points—Wireless access points
(APs) that transmit and receive radio frequency (RF) signals to and from
wireless users and connect them to an MX switch
●
Mobility System Software™ (MSS™)—The operating system that runs all
MX switches and MP access points in a WLAN, and is accessible through a
command-line interface (CLI), the Web View interface, or the RingMaster
GUI
Documentation
Consult the following documents to plan, install, configure, and manage a Trapeze
Networks Mobility System.
Planning, Configuration, and Deployment
Trapeze RingMaster User’s Guide. Instructions for planning, configuring,
deploying, and managing the entire WLAN with the RingMaster tool suite. Read
this guide to learn how to plan wireless services, how to configure and deploy
Trapeze equipment to provide those services, and how to optimize and manage
your WLAN.
Trapeze RingMaster Reference Manual. Detailed instructions and information for
all RingMaster planning, configuration, and management features.
Trapeze Mobility Point Installation Guide
Documentation
Chapter 1
Installation
●
Trapeze Mobility System Software Quick Start Guide. Instructions for
performing basic setup of secure (802.1X) and guest (Web AAA) access, for
configuring a Mobility Domain for roaming, and for accessing a sample
network plan in RingMaster for advanced configuration and management
●
Trapeze Mobility Exchange Installation and Basic Configuration Guide.
Instructions and specifications for installing an MX switch in a Trapeze
Mobility System WLAN, and basic instructions for deploying a secure IEEE
802.11 wireless service
●
Trapeze Mobility Point Installation Guide. Instructions and specifications for
installing an MP access point and connecting it to an MX switch
●
Trapeze Regulatory Information. Important safety instructions and
compliance information that you must read before installing Trapeze
Networks products
Configuration and Management
●
Trapeze RingMaster Reference Manual. Instructions for planning,
configuring, deploying, and managing the entire WLAN with the RingMaster
tool suite
●
Trapeze Mobility System Software Configuration Guide. Instructions for
configuring and managing the system through the MSS CLI
●
Trapeze Mobility System Software Command Reference. Functional and
alphabetic reference to all MSS commands supported on MX switches and
MP access points
Introducing the Trapeze Networks Mobility System
Documentation
Chapter 1
Safety and Advisory Notices
The following kinds of safety and advisory notices appear in this manual. (For
translations of the warning conventions and of all warnings in this manual, see
Appendix C, “Translated Warning Conventions and Warnings,” on page 61.)
Caution! This situation or condition can lead to data loss or damage to the
product or other property.
Warning! This situation or condition can cause injury.
Warning! High voltage. This situation or condition can cause injury due to
electric shock.
Warning! Radiation. This situation or condition can cause injury due to
improper handling of fiber-optic equipment.
Note. This information is of special interest.
Trapeze Mobility Point Installation Guide
Documentation
Chapter 1
Text and Syntax Conventions
Trapeze manuals use the following text and syntax conventions:
Convention
Use
Monospace text
Sets off command syntax or sample commands and
system responses.
Bold text
Highlights commands that you enter or items you
select.
Italic text
Designates command variables that you replace
with appropriate values, or highlights publication
titles or words requiring special emphasis.
Menu Name > Command Indicates a menu item that you select. For example,
File > New indicates that you select New from the
File menu.
[ ] (square brackets)
Enclose optional parameters in command syntax.
{ } (curly brackets)
Enclose mandatory parameters in command syntax.
| (vertical bar)
Separates mutually exclusive options in command
syntax.
Introducing the Trapeze Networks Mobility System
Documentation
Chapter 1
Trapeze Mobility Point Installation Guide
2
MP Overview
External Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Connection Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
A Trapeze Networks Mobility Point (MP) access point provides IEEE 802.11
wireless access to the network. MP access points are designed for use with a
Trapeze Networks Mobility Exchange (MX) switch. MP access points require
hardware installation only. All configuration for an MP access point takes place
on the MX switch.
This guide describes MP model MP-372. The MP-372 has one 802.11a radio and
one 802.11b/g radio. Both radios have internal diversity omnidirectional antennas.
In addition, both radios have separate jacks for attachment of optional external
sectorized or directional antennas. The antennas must be ordered separately.
Warning! Installation must be performed by qualified service personnel only.
Read and follow all warning notices and instructions marked on the product or
included in the documentation. Before installing the product, read the Trapeze
Regulatory Information document. (For translations of this warning, see
“Qualified Service Personnel Warning” on page 63.)
Note. The MP radios are disabled by default and can be enabled only by a
system administrator using the MX switch.
MP Overview
External Hardware Features
Chapter 2
External Hardware Features
Figure 1 and Figure 2 show the external hardware features of the MP-372.
Figure 1.
MP Access Point Model MP-372—Top View
Diameter
16.76 cm
(6.6 inches)
Figure 2.
840-9502-0040
Height
4.69 cm
(1.85 inches)
MP Access Point Model MP-372—Bottom View
External antenna
connectors
Kensington security
slot
802.11a
840-9502-0007
Unlock
802.11b/g
RJ-45
ports
Port 2
Port 1
Trapeze Mobility Point Installation Guide
External Hardware Features
Chapter 2
Cable Ports
The MP-372 has two RJ-45 ports. (See Figure 2.) Each port provides a
10/100BASE-TX Ethernet connection to an MX switch. The connection can be
direct to an MX-switch or indirect through an intermediate Layer 2 or Layer 3
network.
The MP receives power and data through the RJ-45 ports. Use a Category 5
(Cat 5) cable with straight-through signaling and standard RJ-45 connectors to
connect an MP to an MX switch or other device in the network. The MP-372
supports 802.3af, and also can receive PoE from Trapeze switches and
Trapeze-approved power injectors. (See the Release Notes for Trapeze Networks
Mobility Point Access Points.)
The two RJ-45 ports support dual-homed configurations for redundancy. An MP
uses only one link for booting, configuration, and data transfer. If the link
becomes unavailable, the MP can reboot using the other link. The ports are
identical except for logical numbering (1 or 2). You can use either port to connect
an MP access point to an MX switch. However, an MP always attempts to boot on
MP port 1 first. Only if the boot attempt on port 1 fails does the MP attempt to
boot on port 2. If one port becomes unavailable, the other port can provide full
power to the MP.
Note. MP access points do not support daisy-chain configurations. Do not
connect the MP access point to another MP access point.
MP Overview
External Hardware Features
Chapter 2
External Antenna Connectors
The MP-372 has connectors for attaching optional external antennas. (See
Figure 2.) Table 1 lists the external antenna models.
Table 1.
Trapeze External Antenna Models
Model
Type
Gain
802.11a
ANT-5120
(ASTN6T)
Beamwidth
Horizontal
Vertical
14.5 dBi
60°
14°
802.11a
12.5 dBi
120°
14°
ANT-5180
(ASTN6H)
802.11a
10.8 dBi
180°
14°
ANT-1060
802.11b/g
10 dBi
60°
65°
ANT-1120
802.11b/g
7 dBi
120°
60°
ANT-1180
802.11b/g
6 dBi
180°
40°
ANT-5060
(ASTN6S)
1.
The numbers in parentheses are the numbers that appear on the back of an 802.11a antenna’s reflector plate.
To verify an 802.11a external antenna’s model number, look for the number in parentheses.
Note. The MP-372 radios are certified for use only with these external
antennas.
Figure 3 shows the 802.11b/g antennas.
10
Trapeze Mobility Point Installation Guide
External Hardware Features
Chapter 2
Figure 3.
External 802.11b/g Antennas
Model ANT-1120
Model ANT-1180
840-9502-0077
Model ANT-1060
The 802.11a external antennas look similar to the 802.11b/g model ANT-1180, but
each has a reflector plate specific to the model number. You can identify an
802.11a external antenna’s model by looking on the back of its reflector plate. Do
not reverse or remove the reflector plate. It is required for antenna operation.
Each antenna comes with a connector cable, mounting hardware, and installation
instructions.
Caution! The external connectors on the MP are labeled: 11B/G and 11A.
Each connector is a standard SMA connector. Make sure you attach the
antenna to the correct connector.
Note. Operation in the band 5.15–5.25 Ghz is restricted to indoor use only.
MP Overview
11
External Hardware Features
Chapter 2
Kensington Security Slot
Models MP-372 has a slot for attachment of a Kensington security cable. The
cable is not included with the MP but can be ordered separately.
MP Mounting Options
You can mount an MP access point on any of the following types of surfaces:
●
Suspended T-bar ceiling
●
Junction box
●
Solid surface wall or ceiling
●
Tabletop
Note. The solid surface mounting option requires Cat 5 cable that does not
have strain relief. The other mounting options can use Cat 5 cable with or
without strain relief.
Status LEDs
The MP has LEDs that provide status information for the device. Figure 4 shows
the locations of the LEDs. Table 2 describes the LEDs.
Health and Radio LEDs—MP-372
Radio 1 LED
Radio 2 LED
Health LED
12
840-9502-0010
Figure 4.
Trapeze Mobility Point Installation Guide
External Hardware Features
Chapter 2
Table 2.
MP Access Point LEDs—MP-372
LED
Appearance
Meaning
Health
Solid green
All the following are true:
• Management link with an MX switch is
operational.
• MP access point has booted.
• MP access point has received a valid
configuration from an MX switch.
• At least one radio is enabled or is in sentry
mode.
Solid amber
MP access point is waiting to receive boot
instructions and a configuration file from an MX
switch.
Alternating green and MP access point is booting and receiving its
amber
configuration file from an MX switch.
Radio 1
Radio 2
Solid green
A client is associated with the radio.
Blinking green
Associated client is sending or receiving traffic.
Blinking amber
Non-associated client is sending or receiving
traffic.
Alternating green and Radio is unable to transmit. This state can occur
amber
due to any of the following:
• Excessive radio interference in the
environment is preventing the radio from
sending beacons.
• The radio has failed.
Unlit
Means one of the following:
• Radio is disabled.
• Radio is enabled, but no clients are associated
with the radio and there is no traffic activity.
MP Overview
13
Connection Options
Chapter 2
Connection Options
You can connect an MP access port directly to an MX switch port or indirectly to
MX switches through an intermediate Layer 2 or Layer 3 network. In either case,
use Category 5 (CAT 5) cable with straight-through signaling for each MP
connection.
You also can provide data link redundancy by connecting both of its ports directly
to MX switch ports or indirectly to MX switches through the network.
You can provide MX management redundancy even on a single MP Ethernet port
by connecting the MP indirectly to multiple MX switches through an intermediate
Layer 2 or Layer 3 network.
Note. Install the Cat 5 cables for the MP access point at the installation site
before installing the access point itself. During installation, you will insert the
Cat 5 cable(s) into the MP port(s) before attaching the access point to the
bracket.
14
Trapeze Mobility Point Installation Guide
3
Installing and Connecting
an MP-372
Unpacking an MP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Installation Requirements and Recommendations . . . . . . . . . . . . . . . . . . . . . 18
Installing an MP-372 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Connecting an MP to an MX Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Verifying MP Health . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Note. Before installing an MP access point, you might need to generate a
network plan and an MP work order with RingMaster. (See “RingMaster Network
Plan and Work Orders” on page 18.)
Installing and Connecting an MP-372
15
Unpacking an MP
Chapter 3
Unpacking an MP
The shipping carton for an MP access point contains the following items:
●
One MP access point
●
Mounting kit:
●
16
●
One universal mounting bracket (attached to the MP)
●
One paper mounting template (used for marking cutting areas and screw
holes)
●
One two-piece 14.2-mm (9/16-inch) T-bar clamp
●
One two-piece 15.9-mm (5/8-inch) T-bar clamp
●
One two-piece 23.9-mm (15/16-inch) T-bar clamp
●
Two #6 sheet metal screws and two drywall anchors
●
Three adhesive rubber feet
One documentation pack that includes quick mounting instructions and a
registration card (not shown)
Trapeze Mobility Point Installation Guide
Unpacking an MP
Chapter 3
Figure 5 shows the contents of the shipping carton for model MP-372.
Figure 5.
MP-372 Shipping Carton Contents
Mounting template
Rubber feet
T-bar clamps
Universal
mounting bracket
840-9502-0001
Mobility point
Mounting hardware
Before you begin installation:
Open the carton and carefully remove the contents, if you have not already
done so.
Place the packing materials back in the carton and save the carton.
Verify that you received each item in the previous list. If any item is missing
or damaged, contact Trapeze Networks.
Installing and Connecting an MP-372
17
Installation Requirements and Recommendations
Chapter 3
Installation Requirements and
Recommendations
For best results, follow these requirements and recommendations before installing
an MP access point.
RingMaster Network Plan and Work Orders
If you are using RingMaster to plan your Trapeze Networks Mobility System
installation, you might want to create and verify a network plan for the entire
Trapeze network installation and generate an MP work order, before installing MP
access points. A network plan and the MP work orders generated from it provide
the following information about MP access point installation and configuration:
●
Number of MP access points required for adequate WLAN capacity in each
coverage area
●
Detailed installation location for each MP access point
●
Settings for all MP access points in the WLAN
(For information about installing RingMaster, creating and verifying a network
plan, and generating an MP work order, see the Trapeze RingMaster User’s Guide
and Trapeze RingMaster Reference Manual.)
MX Switch Recommendation
Trapeze Networks recommends that you install and configure the MX switch
before installing an MP access point. If the switch is already installed and
configured for the MP access point(s), you can immediately verify the cable
connection(s) when you plug the cable(s) into the MP access point.
Caution! MP model MP-372 is designed to receive power only from an
802.3af-compliant source, a Trapeze Networks Mobility Exchange (MX) switch,
or a Trapeze-approved power injector. Connecting an MP access point to a
Power over Ethernet (PoE) device that is not approved by Trapeze Networks
can damage the equipment.
18
Trapeze Mobility Point Installation Guide
Installation Requirements and Recommendations
Chapter 3
(For information about connecting an MP access point to an MX switch port, see
“Connecting an MP to an MX Switch” on page 50.)
Wall Installation Recommendations
If you plan to install an MP on a partial wall or other vertical surface, orient the
top of the access point (the side with the LEDs) toward the intended coverage
area. The radio antennas transmit through the top of the access point but not
through the bottom (where the bracket is).
This recommendation does not apply if you plan to use external antennas. You can
orient the antennas independently of the MP itself. Orient an external antenna to
face the intended coverage area.
MP Radio Safety Advisories
When you enable the MP radio(s) as part of MX switch configuration, the radios
are able to receive and transmit radio frequency energy as soon as you connect the
MP access point(s) to the MX switch, either directly or through the network.
Radio Frequency Exposure
Federal Communications Commission (FCC) Docket 96-8 for Spread Spectrum
Transmitters specifies a safety standard for human exposure to radio frequency
electromagnetic energy emitted by FCC-certified equipment. When used with the
proper antennas (shipped in the product), Trapeze Networks MP access point
products meet the uncontrolled environmental limits found in OET-65 and
ANSI C95.1-1991. Proper installation of the MP access point according to the
instructions in this manual will result in user exposure that is below the FCC
recommended limits.
Additional Radio Safety Advisories
(For translations of warnings, see “Radio Safety Warnings” on page 64.)
Warning! In the U.S., locate the MP access point and any externally attached
antennas a minimum of 20 cm (7.9 inches) away from people. This safety
warning conforms with FCC radio frequency exposure limits for dipole antennas
such as those used in the MP access point.
Installing and Connecting an MP-372
19
Installation Requirements and Recommendations
Chapter 3
Warning! Do not operate the MP access point near unshielded blasting caps
or in an otherwise explosive environment unless the device has been modified
for such use by qualified personnel.
Warning! Do not touch or move the MP access point when the antennas are
transmitting or receiving.
Warning! Do not hold any radio device so that the antenna is very close to or
touching the face, eyes, or other exposed body part while the device's radio
antenna is transmitting.
Warning! Before using a wireless device in a hazardous location, consult the
local codes, national codes, and safety directors of the location for usage
constraints.
Cable Requirements
Warning! Do not connect or disconnect cables or otherwise work with the MP
access point hardware during periods of lightning activity. (For translations of
this warning, see “Lightning Warning” on page 67.)
Note. The MP access point is intended for indoor use only. Do not install the
device outdoors, unless you install it in a properly installed Trapeze Networks
outdoor MP enclosure.
Note. To reduce the possibility of connection interference caused by dust,
clean the Cat 5 connector pins before inserting a cable into an MP access point.
20
Trapeze Mobility Point Installation Guide
Installation Requirements and Recommendations
Chapter 3
Cat 5 cable with straight-through signaling must be installed at the site before you
install an MP access point. A single connection requires one cable. A dual-homed
connection requires two cables.
Table 3 lists the pin signals for 10/100 Ethernet straight-through wiring. Pins 4, 5,
7, and 8 are used when Trapeze Power over Ethernet (PoE) is enabled on the port.
RD means Receive Data and TD means Transmit Data.
Table 3.
10/100 Ethernet Straight-Through Pin Signals
MX Switch
Other Device
Pin
Function
Pin
Function
RD+
TD+
RD-
TD-
TD+
RD+
PoE+
PoE+
PoE+
PoE+
TD-
RD-
PoE-
PoE-
PoE-
PoE-
Mounting an MP access point on a solid surface requires Cat 5 cable that does not
have strain relief. For installation on all other surfaces, you can use Cat 5 cable
with or without strain relief.
(For more information about cables, see “Cable Ports” on page 9.)
Installing and Connecting an MP-372
21
Installing an MP-372
Chapter 3
Installing an MP-372
To install an MP-372, use one of the procedures in this section.
Installation Hardware and Tools
Table 4 lists the mounting hardware and tools required for each type of
installation.
Table 4.
Required Mounting Hardware and Tools—Model MP-372
Mounting Option
Required Hardware and Tools
Included with the
Product
Suspended ceiling—flush
ceiling tiles
Mounting template
Yes
Universal mounting bracket
Yes
T-bar clamp
Yes
Note: A T-bar clamp is not required
for a 23.9-mm (15/16-inch) T-bar
ceiling with flush ceiling tiles.
Suspended ceiling—drop
ceiling tiles
22
Box cutter
No
Small screwdriver (3-mm or
1/8-inch)
No
Mounting template
Yes
Universal mounting bracket
Yes
T-bar clamp
Yes
Box cutter
No
Small screwdriver (3-mm or
1/8-inch)
No
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Table 4.
Required Mounting Hardware and Tools—Model MP-372
Mounting Option
Required Hardware and Tools
Included with the
Product
Junction box
Junction box
No
Two #6-32 x 1-inch machine screws Yes
Solid wall or ceiling
Tabletop
Universal mounting bracket
Yes
Small screwdriver (3-mm or
1/8-inch)
No
#2 Phillips-head screwdriver
No
Two #6 sheet metal screws and two Yes
drywall anchors
Universal mounting bracket
Yes
Hammer
No
Small screwdriver (3-mm or
1/8-inch)
No
#2 Phillips-head screwdriver
No
Universal mounting bracket
Yes
Three adhesive rubber feet
Yes
Small screwdriver (3-mm or
1/8-inch)
No
Note. The MP-372 model is UL2043 plenum rated, so it also can be installed in
the space above the ceiling if preferred.
Figure 6 shows the universal mounting bracket.
Installing and Connecting an MP-372
23
Installing an MP-372
Chapter 3
Figure 6.
Universal Mounting Bracket
Port connector
opening
T-bar flanges
840-9502-0018
Screw holes
Suspended Ceiling Installation—Flush Ceiling Tiles
(For required mounting hardware and tools, see Table 4 on page 22.)
Select an installation location that is centered over a T-bar in the ceiling.
Cut a hole as follows in the ceiling tile for the Cat 5 cable(s):
24
Place the mounting template over the area where you plan to install the
MP access point.
Use the box cutter to cut along the line marking the opening for the port
connectors.
Remove the mounting template and the material you cut from the ceiling
panel.
Determine whether to install a T-bar clamp onto the ceiling T-bar:
●
If the T-bar width is 14.2 mm (9/16 inches), you need to install the
14.2-mm (9/16-inch) T-bar clamp. Go to step 4.
●
If the T-bar width is 23.9 mm (15/16 inches), the universal mounting
bracket fits directly onto the T-bar. Go to step 5.
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Figure 7.
Install the 14.2-mm (9/16-inch) T-bar clamp onto the ceiling T-bar as shown
in Figure 7.
Slide each half of the clamp onto the T-bar so that the clamp lip is fully on
the T-bar.
Slide the two halves of the clamp toward each other until the tabs are
inserted completely into the holes and the clamp fits snugly on the T-bar.
Step 4—Installing a T-bar Clamp
T-bar
Slide together
840-9502-0003
T-bar clamp halves
Unlock the universal mounting bracket from the MP access point by inserting
the 3-mm or 1/8-inch screwdriver into the Unlock hole on the MP access point
as shown in Figure 8.
Caution! To avoid damage to the MP access point’s lock mechanism
or electronic components, do not use excessive force when inserting a
tool into the Unlock or Lock hole.
Installing and Connecting an MP-372
25
Installing an MP-372
Chapter 3
Step 5—Unlocking the Bracket
840-9502-0011
Figure 8.
Remove the bracket as shown in Figure 9.
Step 6—Removing the Bracket
840-9502-0008
Figure 9.
Install the universal mounting bracket as follows onto the T-bar or T-bar
clamp:
26
As shown in Figure 10, place the universal mounting bracket against the
T-bar or clamp so that the two screw holes face downward and the two
T-bar flanges face upward and are adjacent to the T-bar edges.
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Figure 10. Step 7—Top View
Universal mounting
bracket
T-bar
840-9502-0005
Port connector
opening
(Viewed from above ceiling tiles, looking down.)
Properly align the bracket for mounting by placing the bracket so that its
port connector opening is to the left of the hole you cut for the cables.
Rotate the universal mounting bracket clockwise until the flanges snap
into place on the T-bar or clamp as shown in Figure 11.
Figure 11. Step 7—Bottom View
Port connector
opening
Universal mounting bracket
840-9502-0004
T-bar
Pull the Cat 5 cable(s) about 15 cm (about 6 inches) out of the hole in the
ceiling tile and through the port connector opening to create enough slack to
insert the cable(s).
Installing and Connecting an MP-372
27
Installing an MP-372
Chapter 3
10
11
Insert the Cat 5 cable(s) into the connector(s):
●
For a single connection, use the connector for port 1.
●
For redundancy, insert one cable into each connector.
Install the Kensington lock, if you plan to used one.
Loop the Kensington lock’s cable around an object that cannot be moved
or damaged by a person pulling on the cable.
Insert the key into the Kensington lock.
Insert the Kensington lock into the security slot on the MP.
Rotate the key right or left to secure the lock to the MP.
Pull on the lock to verify that it is secured to the MP.
Remove the key.
Lift the MP access point into place on the universal mounting bracket as
shown in Figure 12.
Make sure the cable feeds properly into the ceiling as you lift the device, and
does not become trapped between the access point and the bracket.
840-9502-0002
Figure 12. Step 10—Placing the MP Access Point on the Bracket
28
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
12
Lock the MP access point onto the bracket by inserting the 3-mm or 1/8-inch
screwdriver into the Lock hole on the access point as shown in Figure 13.
Caution! To prevent possible damage to the MP access point, make
sure the device is fully locked onto the bracket before letting go of it.
Figure 13. Step 11—Locking the Bracket
Lock
840-9502-0006
T-bar
13
To ensure that the MP access point is fully locked onto the bracket, gently pull
down on the access point and attempt to rotate it from side to side.
14
If the access point comes off the bracket, relock the device onto the bracket as
described in step 12 on page 29.
15
If the MP requires an external antenna, install and connect the antenna. (See
“Connecting an MP to an External Antenna” on page 49.)
16
If the other ends of the Cat 5 cable(s) are not already connected and the link
activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise,
go to “Verifying MP Health” on page 52.
Installing and Connecting an MP-372
29
Installing an MP-372
Chapter 3
Suspended Ceiling Installation—Drop Ceiling Tiles
(For required mounting hardware and tools, see Table 4 on page 22.)
Select an installation location that is centered over a T-bar in the ceiling.
Cut a hole as follows in the ceiling tile for the Cat 5 cable(s):
Place the mounting template over the area where you plan to install the
MP access point.
Use the box cutter to cut along the line marking the opening for the port
connectors.
Remove the mounting template and the material you cut from the ceiling
panel.
Install the T-bar clamp that fits the T-bar:
Slide each half of the clamp onto the T-bar so that the clamp lip is fully on
the T-bar.
Slide the two halves of the clamp toward each other until the tabs are
inserted completely into the holes and the clamp fits snugly on the T-bar.
Figure 14 shows an example for a 23.9-mm (15/16-inch) T-bar. Figure 15
shows an example for a 15.9-mm (5/8-inch) T-bar.
Figure 14. Step 3—Installing the T-bar Clamp for a 23.9-mm
(15/16-inch) T-bar
T-bar
Slide together
840-9502-0003
T-bar clamp halves
30
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Figure 15. Step 3—Installing the T-bar Clamp for a 15.9-mm
(5/8-inch) T-bar
T-bar
Slide together
840-9502-0066
T-bar clamp halves
Unlock the universal mounting bracket from the MP access point by inserting
the 3-mm or 1/8-inch screwdriver into the Unlock hole on the MP access point
as shown in Figure 16.
Caution! To avoid damage to the MP access point’s lock mechanism
or electronic components, do not use excessive force when inserting a
tool into the Unlock or Lock hole.
840-9502-0011
Figure 16. Step 4—Unlocking the Bracket
Installing and Connecting an MP-372
31
Installing an MP-372
Chapter 3
Remove the bracket as shown in Figure 17.
840-9502-0008
Figure 17. Step 5—Removing the Bracket
32
Install the universal mounting bracket as follows onto the T-bar clamp:
As shown in Figure 18, place the universal mounting bracket against the
T-bar clamp so that the two screw holes face downward and the two T-bar
flanges face upward and are adjacent to the T-bar edges.
Properly align the bracket for mounting by placing the bracket so that its
port connector opening is to the left of the hole you cut for the cables.
Rotate the universal mounting bracket clockwise until the flanges snap
into place on the T-bar clamp as shown in Figure 19.
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Figure 18. Step 6—Top View
Universal mounting
bracket
T- bar
840-9502-0012
T-bar clamps
(attached
to T-bar)
Port connector
opening
(Viewed from above ceiling tiles, looking down.)
Figure 19. Step 6—Bottom View
Port connector
opening
Universal mounting bracket
840-9502-0004
T-bar
Pull the Cat 5 cable(s) about 15 cm (about 6 inches) out of the hole in the
ceiling tile and through the port connector opening to create enough slack to
insert the cable(s).
Insert the Cat 5 cable(s) into the connector(s):
●
For a single connection, use the connector for port 1.
●
For redundancy, insert one cable into each connector.
Installing and Connecting an MP-372
33
Installing an MP-372
Chapter 3
10
Install the Kensington lock, if you plan to used one.
Loop the Kensington lock’s cable around an object that cannot be moved
or damaged by a person pulling on the cable.
Insert the key into the Kensington lock.
Insert the Kensington lock into the security slot on the MP.
Rotate the key right or left to secure the lock to the MP.
Pull on the lock to verify that it is secured to the MP.
Remove the key.
Lift the MP access point into place on the universal mounting bracket as
shown in Figure 20.
Make sure the cable feeds properly into the ceiling as you lift the device, and
does not become trapped between the access point and the bracket.
840-9502-0002
Figure 20. Step 9—Placing the MP Access Point on the Bracket
11
Lock the MP access point onto the bracket by inserting the 3-mm or 1/8-inch
screwdriver into the Lock hole on the access point as shown in Figure 21.
Caution! To prevent possible damage to the MP access point, make
sure the device is fully locked onto the bracket before letting go of it.
34
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Figure 21. Step 10—Locking the Bracket
Lock
840-9502-0006
T-bar
12
To ensure that the MP access point is fully locked onto the bracket, gently pull
down on the access point and attempt to rotate it from side to side.
If the access point comes off the bracket, relock the device onto the bracket as
described in step 11 on page 34.
13
If the MP requires an external antenna, install and connect the antenna. (See
“Connecting an MP to an External Antenna” on page 49.)
14
If the other ends of the Cat 5 cable(s) are not already connected and the link
activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise,
go to “Verifying MP Health” on page 52.
Installing and Connecting an MP-372
35
Installing an MP-372
Chapter 3
Junction Box Installation
(For required mounting hardware and tools, see Table 4 on page 22.)
Unlock the universal mounting bracket from the MP access point by inserting
the 3-mm or 1/8-inch screwdriver into the Unlock hole on the MP access point
as shown in Figure 22.
Caution! To avoid damage to the MP access point’s lock mechanism
or electronic components, do not use excessive force when inserting a
tool into the Unlock or Lock hole.
840-9502-0011
Figure 22. Step 1—Unlocking the Bracket
36
Remove the bracket as shown in Figure 23.
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
840-9502-0008
Figure 23. Step 2—Removing the Bracket
Attach the universal mounting bracket to the junction box as shown in
Figure 24:
Place the universal mounting bracket against the junction box so that the
two screw holes face the junction box and align over the screw holes in
the box.
Insert the #6-32 x 1-inch machine screws in the universal mounting
bracket’s screw holes, and use a #2 Phillips-head screwdriver to tighten
them.
Installing and Connecting an MP-372
37
Installing an MP-372
Chapter 3
Figure 24. Step 3—Placing the Bracket on the Junction Box
Junction box
840-9502-0017
Port connector
opening
Pull the Cat 5 cable(s) about 15 cm (about 6 inches) out of the junction box
and through the port connector opening to create enough slack to insert the
cable(s) into the port connectors.
Insert the Cat 5 cable(s) into the connector(s):
38
●
For a single connection, use the connector for port 1.
●
For redundancy, insert one cable into each connector.
Install the Kensington lock, if you plan to used one.
Loop the Kensington lock’s cable around an object that cannot be moved
or damaged by a person pulling on the cable.
Insert the key into the Kensington lock.
Insert the Kensington lock into the security slot on the MP.
Rotate the key right or left to secure the lock to the MP.
Pull on the lock to verify that it is secured to the MP.
Remove the key.
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Lift the MP access point into place on the universal mounting bracket.
Make sure the cable feeds properly into the junction box as you lift the device,
and does not become trapped between the access point and the bracket.
Lock the MP access point onto the bracket by inserting the 3-mm or 1/8-inch
screwdriver into the Lock hole on the access point as shown in Figure 25.
Caution! To prevent possible damage to the MP access point, make
sure the device is fully locked onto the bracket before letting go of it.
840-9502-0062
Figure 25. Step 7—Locking the Bracket
Lock
To ensure that the MP access point is fully locked onto the bracket, gently pull
down on the access point and attempt to rotate it from side to side.
If the access point comes off the bracket, relock the device onto the bracket as
described in step 8 on page 39.
10
If the MP requires an external antenna, install and connect the antenna. (See
“Connecting an MP to an External Antenna” on page 49.)
11
If the other ends of the Cat 5 cable(s) are not already connected and the link
activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise,
go to “Verifying MP Health” on page 52.
Installing and Connecting an MP-372
39
Installing an MP-372
Chapter 3
Solid Wall or Ceiling Installation
Note. The solid surface mounting option requires Cat 5 cable that does not
have strain relief, unless you plan to route the cable through a hole in the wall
or ceiling. The other options can use Cat 5 cable with or without strain relief.
(For required mounting hardware and tools, see Table 4 on page 22.)
Prepare holes in the wall or ceiling for the universal mounting bracket, using
the following steps:
Place the paper mounting template over the location where you want to
install the MP access point.
Mark the screw hole location(s).
❍
❍
If you plan to route the Cat 5 cable externally along the wall or
ceiling, mark the locations of both the center screw hole and the
screw hole by the port connector opening.
If you plan to route the Cat 5 cable through a hole in the wall or
ceiling, mark the location of the center screw hole only. You cannot
use the screw hole by the port connector opening if you cut a hole for
the opening.
Note. Do not mark the four holes on the edges of the bracket. (These
are the holes indicated by the dashed lines in Figure 28.) The MP access
point fits into these holes. They are not screw holes.
40
Remove the template.
Install the drywall anchor(s):
Hammer a drywall anchor into each hole, up to the beginning of the
threads on the anchor.
Screw each anchor the rest of the way into its hole using a
#2 Phillips-head screwdriver.
Remove the screw from each anchor and save the screw(s) for step 6 on
page 42.
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Unlock the universal mounting bracket from the MP access point by inserting
the 3-mm or 1/8-inch screwdriver into the Unlock hole on the MP access point
as shown in Figure 26.
Caution! To avoid damage to the MP access point’s lock mechanism
or electronic components, do not use excessive force when inserting a
tool into the Unlock or Lock hole.
840-9502-0011
Figure 26. Step 3—Unlocking the Bracket
Remove the bracket as shown in Figure 27.
840-9502-0008
Figure 27. Step 4—Removing the Bracket
Installing and Connecting an MP-372
41
Installing an MP-372
Chapter 3
As shown in Figure 28, feed the Cat 5 cable(s) through the port connector
opening and align the universal mounting bracket over the drywall anchors so
that the two screw holes in the bracket face the drywall anchors.
Insert the #6 sheet metal screws into the screw holes, and tighten them to
secure the universal mounting bracket to the wall or ceiling.
(If you routed the Cat 5 cable through a hole in the wall or ceiling, insert the
screw into the center screw hole only.)
Note. Do not insert screws in the four holes on the edges of the
bracket. (These are the holes indicated by the dashed lines in
Figure 28.) The MP access point fits into these holes. They are not
screw holes.
840-9502-0015
Figure 28. Steps 5 and 6—Bracket Placement on Solid Wall or Ceiling
42
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Insert the Cat 5 cable(s) into the connector(s):
●
For a single connection, use the connector for port 1.
●
For redundancy, insert one cable into each connector.
Install the Kensington lock, if you plan to used one.
Loop the Kensington lock’s cable around an object that cannot be moved
or damaged by a person pulling on the cable.
Insert the key into the Kensington lock.
Insert the Kensington lock into the security slot on the MP.
Rotate the key right or left to secure the lock to the MP.
Pull on the lock to verify that it is secured to the MP.
Remove the key.
As shown in Figure 29, place the MP access point on the bracket, making sure
to remove any slack that occurs in the cable between the bracket and the MP
access point.
Figure 29. Step 8—Cable Placement
Cable
840-9502-0016
Universal mounting bracket
Installing and Connecting an MP-372
43
Installing an MP-372
Chapter 3
10
Lock the MP access point onto the bracket by inserting the 3-mm or 1/8-inch
screwdriver into the Lock hole on the access point as shown in Figure 30.
Caution! To prevent possible damage to the MP access point, make
sure the device is fully locked onto the bracket before letting go of it.
Lock
11
840-9502-0062
Figure 30. Step 9—Locking the Bracket
To ensure that the MP access point is fully locked onto the bracket, gently pull
on the access point and attempt to rotate it from side to side.
If the access point comes off the bracket, relock the device onto the bracket as
described in step 10 on page 44.
44
12
If the MP requires an external antenna, install and connect the antenna. (See
“Connecting an MP to an External Antenna” on page 49.)
13
If the other ends of the Cat 5 cable(s) are not already connected and the link
activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise,
go to “Verifying MP Health” on page 52.
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Tabletop Installation
(For required mounting hardware and tools, see Table 4 on page 22.)
Reverse the universal mounting bracket:
Unlock the universal mounting bracket from the MP access point by
inserting the 3-mm or 1/8-inch screwdriver into the Unlock hole on the
MP access point as shown in Figure 31.
Caution! To avoid damage to the MP access point’s lock mechanism
or electronic components, do not use excessive force when inserting a
tool into the Unlock or Lock hole.
840-9502-0011
Figure 31. Step 1a—Unlocking the Bracket
Installing and Connecting an MP-372
45
Installing an MP-372
Chapter 3
Remove the bracket as shown in Figure 32.
840-9502-0008
Figure 32. Step 1b—Removing the Bracket
Turn over the universal mounting bracket, then align the bracket over the
cable ports and the four mounting posts as shown in Figure 33.
840-9502-0061
Figure 33. Step 1c—Turning Over the Bracket
46
Once the bracket is fully seated, lock the bracket onto the MP access point
by inserting the 3-mm or 1/8-inch screwdriver into the Lock hole on the
access point as shown in Figure 34.
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
840-9502-0062
Figure 34. Step 1d—Locking the Bracket
Lock
Attach the three rubber adhesive feet onto the universal mounting bracket, in
the three location circles, as shown in Figure 35.
840-9502-0013
Figure 35. Step 2—Installing the Rubber Feet
Insert the Cat 5 cable(s) into the connector(s):
●
For a single connection, use the connector for port 1.
●
For redundancy, insert one cable into each connector.
Installing and Connecting an MP-372
47
Installing an MP-372
Chapter 3
48
Install the Kensington lock, if you plan to used one.
Loop the Kensington lock’s cable around an object that cannot be moved
or damaged by a person pulling on the cable.
Insert the key into the Kensington lock.
Insert the Kensington lock into the security slot on the MP.
Rotate the key right or left to secure the lock to the MP.
Pull on the lock to verify that it is secured to the MP.
Remove the key.
Place the MP access point in the desired location on the table.
If the MP requires an external antenna, install and connect the antenna. (See
“Connecting an MP to an External Antenna” on page 49.)
If the other ends of the Cat 5 cable(s) are not already connected and the link
activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise,
go to “Verifying MP Health” on page 52.
Trapeze Mobility Point Installation Guide
Installing an MP-372
Chapter 3
Connecting an MP to an External Antenna
Each radio in an MP-372 can use an optional Trapeze external antenna. To mount
the antenna, see the instructions that come with the antenna.
Caution! The external antenna must be installed at least 20 cm from the MP
access point.
To connect a mounted external antenna to an MP-372:
Attach the exterior antenna cable that is shipped with the antenna to the MP
external antenna connector.
Both connectors are labeled to indicate the radio type. The MP has standard
SMA connectors for attachment to the 802.11b/g antenna and to the 802.11a
antenna.
(For the location of the external antenna connectors, see Figure 2 on page 8.)
Caution! The external connectors on the MP are labeled: 11B/G and
11A. Each connector is a standard SMA connector. Make sure you attach
the antenna to the correct connector.
Note. If the MP is installed in a Trapeze Networks outdoor MP
enclosure, attach the antenna cable to the lightning surge arrestor (if
installed) or the enclosure’s SMA bulkhead connector.
Attach the other end of the antenna cable to the antenna.
If the other ends of the Cat 5 cable(s) are not already connected and the link
activated, go to “Connecting an MP to an MX Switch” on page 50. Otherwise,
go to “Verifying MP Health” on page 52.
Installing and Connecting an MP-372
49
Connecting an MP to an MX Switch
Chapter 3
Connecting an MP to an MX Switch
You can connect an MP access point directly to an MX switch or indirectly to the
switch through an intermediate Layer 2 or Layer 3 network.
●
To connect the MP directly to an MX switch, configure the MX switch port as
an MP access port and use the following procedure to insert the cable into the
MX switch and verify the link.
●
To connect the MP indirectly to an MX switch though the network, configure
a Distributed MP connection on the MX switch.
You can use the CLI or RingMaster to configure an MP access port or Distributed
MP connection. (See the Trapeze Mobility System Software Configuration Guide
or the Trapeze RingMaster User’s Guide.)
Figure 36 shows how to insert a Cat 5 cable into 10/100 Ethernet port on an MX
switch. Refer to this figure as you perform the procedure.
Figure 36. 10/100 Cat 5 Cable Installation
Ethernet port
MX-20
Ethernet cable
(Cat 5 cable)
50
MP, switch, server
or other device
Insert a Cat 5 cable with a standard RJ-45 connector as shown in Figure 36.
For connection to an MP access point, use a straight-through cable.
Trapeze Mobility Point Installation Guide
840-9502-0058
ange
y Exch
Mobilit
Connecting an MP to an MX Switch
Chapter 3
When the link is activated, observe the MP LED for the port on the MX
switch:
MP LED Appearance
Meaning
Solid green
For an MP access point’s active link, all the
following are true:
• MP access point has booted.
• MP access point has received a valid
configuration from the MX switch.
• Management link with an MP access point is
operational.
• At least one radio is enabled or is in sentry
mode.
For an MP access point’s secondary link, the
link is present.
Alternating green and
amber
MP access point is booting with an image
received from the MX switch. After the access
point boots and receives its configuration, this
LED appearance persists until a radio is enabled
or is placed in sentry mode.
Solid amber
PoE is on.
Blinking amber
MP is unresponsive or there is a PoE problem.
Unlit
PoE is off.
Note. An MX switch’s 10/100 Ethernet ports are configured as wired network
ports by default. You or the system administrator must change the port type for
an MX port directly connected to an MP to activate the link. (See the Trapeze
Mobility Exchange Installation and Basic Configuration Guide.)
Installing and Connecting an MP-372
51
Verifying MP Health
Chapter 3
Verifying MP Health
After you install the MP access point and enable PoE on the Ethernet cable
connected to the MP, you can easily verify the MP’s status by observing the LEDs,
particularly the health LED. (See Figure 4 on page 12.)
The health or LINK LED indicates whether the MP access point is ready for
operation.
52
●
If the LED is green and glowing steadily, the MP has been booted
successfully by the MX switch and is ready for operation.
●
If the LED is not steadily glowing green, contact the system administrator for
the MX switch or, if you are the system administrator, see Appendix A, “MP
Troubleshooting,” on page 53.
Trapeze Mobility Point Installation Guide
A
MP Troubleshooting
After you insert a Cat 5 cable into an MP access point’s port connector and enable
PoE on the cable, observe the device’s health or LINK LED to determine the
status of the connection with the MX switch.
●
If the LED is green and is glowing steadily, the MP has been booted
successfully by the MX switch and is ready for operation.
●
If the LED is not steadily glowing green, see Table 5.
(For descriptions of all the LEDs, see “Status LEDs” on page 12.)
MP Troubleshooting
53
Appendix A
Table 5.
Health LED States
Health or LINK
LED Appearance
Diagnosis
Remedy
Not solid green
MP radio needs to be
enabled.
Enable at least one of the radios. If
the LED is still not solid green, try
the remedy listed in this table
based on the LED’s appearance.
Unlit
MP access point is not
receiving power.
Check the Cat 5 cable
connection(s).
For a direct connection to an MX
switch:
• Set the port type on the MX
switch to an MP port.
• Verify that Power over Ethernet
(PoE) is enabled on the MX
switch port connected to the
MP access point.
For an indirect connection through
the network:
• Configure a Distributed MP
connection on an MX switch.
• Verify that a Trapeze-approved
PoE source is supplying power
to the MP.
Slowly alternating
green and amber
MP access point is booting Wait a few seconds for the boot
with an image received from process to complete. If this LED
an MX switch.
appearance persists, enable a radio
or place a radio in sentry mode.
Solid amber
MP access point is waiting to
receive boot instructions and
a configuration file from an
MX switch.
54
Wait a few seconds for the boot
process to begin.
If the LED remains amber, try the
remedies for the other health LED
appearances.
If the LED still remains amber,
make sure the MP access point is
securely connected to its PoE
source and to the network or MX
switch.
Trapeze Mobility Point Installation Guide
B
MP Technical Specifications
This appendix lists the technical specifications for the Trapeze Networks MP-372
access point. Table 6 lists the mechanical and compliance specifications. (For
detailed compliance information, see the Trapeze Regulatory Information
document.) Table 7, Table 8, and Table 9 list the radio specifications. Table 10
lists the MAC address allocation scheme.
(For specifications for the MX switch, see the Trapeze Mobility Exchange
Installation and Basic Configuration Guide.)
Note. This Listed Accessory is designed and approved to be used only with
Trapeze Networks Mobility Exchange (MX) models MX-20, MX-8, and MXR-2.
(The MX-400 switch does not directly connect to the MP.)
Note. The MP radios are disabled by default and can be enabled only by the
system administrator using the RingMaster management application or the MX
switch’s command-line interface (CLI).
Note. The radio frequency band, operating channels, and transmit power
depend on the country of operation specified by the system administrator using
RingMaster or the MX switch’s CLI.
MP Technical Specifications
55
Appendix B
Table 6.
MP Mechanical and Compliance Specifications
Specification
Description
Size
Diameter: 16.76 cm (6.6 inches)
Height: 4.69 cm (1.85 inches)
Weight
Without mounting bracket: 0.35 kg (12.5 ounces)
With mounting bracket: 0.40 kg (14 ounces)
Operating Temperature
0° C to +50° C (32° F to 122° F)
Storage Temperature
-20° C to +70° C (-4° F to +158° F)
Humidity
10% to 95% noncondensing
Power over Ethernet
(PoE)
42 VDC to 57 VDC (46 VDC nominal)
IEEE 802.3af (MP-341, MP-352, and MP-52)
Status indicators
Health/MX and radio LEDs
(For descriptions of the LEDs, see “Status LEDs” on page 12.)
Wired network ports
Two RJ-45 ports for 10/100BASE-T Ethernet and Power over
Ethernet (PoE)
Standards compliance
IEEE 802.11
IEEE 802.11a
IEEE 802.11b
IEEE 802.11g
IEEE 802.3af
Safety and
electromagnetic
compliance
FCC Part 15, UL 60950
IC Part 15, CSA 22.2 N0-950, RSS-139-1 and RSS-210
ETS 300 328 (2.4 GHz) and 301 893 (5 GHz), EN 301 489-17
R&TTE Directive 1999/5/EC
TELEC, ARIB T66
GBT-15941-1995, GBT-16841-1997
LP0002
56
Trapeze Mobility Point Installation Guide
Appendix B
Table 6.
MP Mechanical and Compliance Specifications (continued)
Specification
Description
Encryption
Wi-Fi Protected Access (WPA)
Advanced Encryption Standard (AES)
40-bit/104-bit Wired-Equivalent Privacy (WEP)
General
Power-save mode supported
Transmit power control in 1 dBm increments
Supports up to 250 clients per radio
Table 7.
802.11a Radio Specifications
Specification
Description
Antenna type
Integrated diversity omnidirectional
External sectorized or directional (optional)
Antenna gain
Internal: 2 dBi
External:
• ANT-5060—14.5 dBi
• ANT-5120—12.5 dBi
• ANT-5180—10.8 dBi
Frequency band
5.15 GHz to 5.85 GHz based on country regulations
Operating channels
Based on the country of operation specified by the system
administrator
Association rates
54 Mbps, 48 Mbps, 36 Mbps, 24 Mbps, 18 Mbps, 12 Mbps,
9 Mbps, and 6 Mbps, with automatic fallback
Modulation
Orthogonal frequency division multiplexing (OFDM)
Transmit power
Based on the country of operation specified by the system
administrator
MP Technical Specifications
57
Appendix B
Table 8.
802.11b Radio Specifications
Specification
Description
Antenna type
Integrated diversity omnidirectional
External sectorized or directional (optional)
Antenna gain
Internal: 2 dBi
External:
• ANT-1060—greater than 10 dBi
• ANT-1120—7 dBi or more
• ANT-1180—6 dBi or more
Frequency band
2.4 GHz to 2.4835 GHz based on country regulations
Operating channels
Based on the country of operation specified by the system
administrator
Association rates
11 Mbps, 5.5 Mbps, 2 Mbps, and 1 Mbps, with automatic
fallback
Modulation
Direct-sequence spread-spectrum (DSSS)
Transmit power
Based on the country of operation specified by the system
administrator
Table 9.
802.11g Radio Specifications
Specification
Description
Antenna type
Integrated diversity omnidirectional
External sectorized or directional (optional)
Antenna gain
Internal: 2 dBi
External:
• ANT-1060—greater than 10 dBi
• ANT-1120—7 dBi or more
• ANT-1180—6 dBi or more
Frequency band
2.4 GHz to 2.4835 GHz based on country regulations
Operating channels
Based on the country of operation specified by the system
administrator
58
Trapeze Mobility Point Installation Guide
Appendix B
Table 9.
802.11g Radio Specifications (continued)
Specification
Description
Association rates
54 Mbps, 48 Mbps, 36 Mbps, 24 Mbps, 18 Mbps, 12 Mbps,
9 Mbps, and 6 Mbps, with automatic fallback
Modulation
Orthogonal frequency division multiplexing (OFDM)
Transmit power
Based on the country of operation specified by the system
administrator
MAC Addresses
Each MP-372 is assigned a unique block of 64 MAC addresses. Each radio has 32
MAC addresses and can therefore support up to 32 SSIDs, with one MAC address
assigned to each SSID as its BSSID.
An MP’s MAC address block is listed on a label on the back of the MP. If the MP
is already deployed and running on the network, you can display the MAC
address assignments by using the show {ap | dap} status command.
All MAC addresses on an MP are assigned based on the MP’s base MAC address,
as described in Table 10.
Table 10. MAC Address Allocations on MP-372
MP base MAC
Address
• The MP has a base MAC address. All the other addresses are
assigned based on this address.
Ethernet Port
MAC Addresses
• Ethernet port 1 equals the MP base MAC address.
• Ethernet port 2 equals the MP base MAC address + 1.
802.11a Radio
and SSID MAC
Addresses
• The 802.11a radio equals the MP base MAC address + 1.
• The BSSIDs for the SSIDs configured on the 802.11a radio end
in odd numbers. The first BSSID is equal to the MP’s base
MAC address + 1. The next BSSID is equal to the MP’s base
MAC address + 3, and so on.
• The 802.11b/g radio equals the MP base MAC address.
The BSSIDs for the SSIDs configured on the 802.11b/g radio
end in even numbers. The first BSSID is equal to the MP’s base
MAC address. The next BSSID is equal to the MP’s base MAC
address + 2, and so on.
802.11b/g Radio •
and SSID MAC
Addresses
MP Technical Specifications
59
Appendix B
60
Trapeze Mobility Point Installation Guide
C
Translated Warning
Conventions and Warnings
The following warning conventions and warnings apply to this manual.
Warning Conventions
Warning! This situation or condition can cause injury.
Waarschuwing! Deze situatie of omstandigheid kan letsel veroorzaken.
Warnung! Diese Situation oder dieser Zustand kann zu Verletzungen führen.
Avertissement ! Cette situation ou cette condition peuvent provoquer des
blessures.
Aviso Esta situación o condición puede causar lesiones.
Translated Warning Conventions and Warnings
61
Appendix C
Warning! High voltage. This situation or condition can cause injury due to
electric shock.
Waarschuwing! Hoog voltage. Deze situatie of omstandigheid kan letsel
veroorzaken door elektrische schokken.
Warnung! Hochspannung. Diese Situation oder dieser Zustand kann einen
Elektroschock verursachen.
Avertissement ! Haute tension. Cette situation ou cette condition peuvent
provoquer des blessures dues à des décharges électriques.
Aviso Alta tensión. Esta situación o condición puede causar lesiones por
descarga eléctrica.
Warning! Radiation. This situation or condition can cause injury due to
improper handling of fiber-optic equipment.
Waarschuwing! Straling. Deze situatie of omstandigheid kan letsel
veroorzaken door onjuist gebruik van glasvezelapparatuur.
Warnung! Strahlung. Diese Situation oder dieser Zustand kann durch
falschen Umgang mit glasfaserbasierten Geräten zu Verletzungen führen.
Avertissement ! Radiation. Cette situation ou cette condition peuvent
provoquer des blessures dues à une manipulation inappropriée d’appareils
équipés de fibres optiques.
Aviso Radiación. Esta situación o condición puede causar lesiones debido a un
manejo inadecuado del equipamiento de fibra óptica.
62
Trapeze Mobility Point Installation Guide
Appendix C
Qualified Service Personnel Warning
Warning! Installation must be performed by qualified service personnel only.
Read and follow all warning notices and instructions marked on the product or
included in the documentation. Before installing the product, read the Trapeze
Regulatory Information document.
Waarschuwing! De installatie mag alleen worden uitgevoerd door bevoegd
onderhoudspersoneel. Het is essentieel dat u kennis neemt van alle
waarschuwingen en instructies aangebracht op het product zelf en/of
opgenomen in de documentatie. Voordat u het product installeert, dient u
Trapeze Regulatory Information in zijn geheel te hebben gelezen.
Warnung! Die Installation darf nur von einem qualifizierten
Kundendienstmitarbeiter vorgenommen werden. Lesen Sie alle Warnhinweise
und Anweisungen auf dem Produkt oder in der Dokumentation und befolgen Sie
sie. Bevor Sie das Produkt installieren, sollten Sie Trapeze Regulatory
Information vollständig lesen.
Avertissement ! L’installation doit être effectuée uniquement par des
techniciens qualifiés. Lisez et suivez toutes les notices d’avertissement et les
instructions figurant sur le produit ou comprises dans la documentation. Lisez l
Trapeze Regulatory Information avant d’installer ce produit.
Aviso Sólo puede realizar la instalación personal cualificado de asistencia
técnica. Lea y siga todas las notas de advertencia e instrucciones indicadas en
el producto o incluidas en la documentación. Antes de instalar el producto, lea
Trapeze Regulatory Information.
Translated Warning Conventions and Warnings
63
Appendix C
Radio Safety Warnings
Warning! Do not operate the MP access point near unshielded blasting caps
or in an otherwise explosive environment unless the device has been modified
for such use by qualified personnel.
Waarschuwing! Het MP-toegangspunt mag niet worden gebruikt in de
nabijheid van onafgeschermde slaghoedjes of in een andere explosieve
omgeving tenzij het apparaat voor een dergelijk gebruik is aangepast door
bevoegd personeel.
Warnung! Die MP-Zugriffspunkte sollten nicht neben ungeschirmten
Sprengkapseln betrieben oder in einer explosiven Umgebung eingesetzt
werden. Für einen solchen Einsatz muss das Gerät von einem qualifizierten
Kundendienstmitarbeiter entsprechend angepasst werden.
Avertissement ! Le point d’accès MP ne doit pas fonctionner près de
détonateurs non blindés ou dans un autre environnement qui présent un risque
d’explosion, à moins que cet appareil n’ait été adapté en vue d’une telle
utilisation par du personnel qualifié.
Aviso No utilice el punto de acceso de MP cerca de detonadores no blindados
ni en un entorno explosivo, a menos que haya sido modificado el dispositivo con
ese fin por personal cualificado.
64
Trapeze Mobility Point Installation Guide
Appendix C
Warning! Do not touch or move the MP access point when the antennas are
transmitting or receiving.
Waarschuwing! Het MP-toegangspunt mag niet worden aangeraakt of
verplaatst terwijl de antennes uitzenden of ontvangen.
Warnung! Berühren oder bewegen Sie den MP-Zugriffspunkt nicht, während
die Antennen senden oder empfangen.
Avertissement ! Ne touchez ni ne déplacez le point d’accès MP lorsque les
antennes sont en cours de transmission ou de réception.
Aviso No toque ni mueva el punto de acceso de MP cuando las antenas estén
transmitiendo o recibiendo señales.
Warning! Do not hold any radio device so that the antenna is very close to or
touching the face, eyes, or other exposed body part while the device's radio
antenna is transmitting.
Waarschuwing! De antenne van een apparaat dat radiogolven aan het
uitzenden is, mag nooit vlakbij of tegen het gezicht, de ogen of een andere
onbedekt deel van het lichaam worden gehouden.
Warnung! Halten Sie die drahtlosen Geräte während der Übertragung mit
der Antenne nicht nahe ans Gesicht, an die Augen oder an andere ungeschützte
Körperteile und berühren Sie die Antenne nicht.
Avertissement ! Ne maintenez pas l’antenne d’un appareil radio près du
visage, des yeux ou d’une autre partie du corps exposée ou en contact avec ces
parties du corps, lorsqu’elle est en cours de transmission.
Aviso No coloque ningún dispositivo de radio demasiado cerca de la antena ni
en contacto con la cara, los ojos u otras partes del cuerpo que estén al
descubierto mientras la antena de radio del dispositivo esté transmitiendo
señales.
Translated Warning Conventions and Warnings
65
Appendix C
Warning! Before using a wireless device in a hazardous location, consult the
local codes, national codes, and safety directors of the location for usage
constraints.
Waarschuwing! Voordat u een draadloos apparaat gebruikt op een
gevaarlijke locatie, dient u de plaatselijke en landelijke voorschriften, en de
veiligheidsvoorschriften voor de locatie te raadplegen over eventuele
gebruiksbeperkingen.
Warnung! Bevor Sie drahtlose Geräte an einem gefährlichen Standort
einsetzen, sollten Sie die lokalen und nationalen Regelungen und
Sicherheitsbestimmungen des Standorts auf Nutzungsbeschränkungen
überprüfen.
Avertissement ! Avant d’utiliser un appareil sans fil dans un endroit
dangereux, consultez la réglementation locale et nationale ainsi que les
responsables de la sécurité de l’endroit concerné pour obtenir des informations
relatives aux conditions et aux limites d’utilisation de cet appareil.
Aviso Antes de utilizar un dispositivo inalámbrico en una ubicación peligrosa,
consulte los códigos locales y nacionales y a los responsables de seguridad de
la ubicación para conocer las restricciones de uso.
66
Trapeze Mobility Point Installation Guide
Appendix C
Lightning Warning
Warning! Do not connect or disconnect cables or otherwise work with the MP
access point hardware during periods of lightning activity.
Waarschuwing! Tijdens onweer met bliksem mogen kabels nooit worden
aangekoppeld aan of losgekoppeld van het MP-toegangspunt of andere
werkzaamheden aan het MP-toegangspunt worden verricht.
Warnung! Verbinden und trennen Sie während eines Gewitters keine Kabel
zum MP-Zugriffspunkt und arbeiten Sie nicht damit.
Avertissement ! Ne connectez pas et ne déconnectez pas de câbles et, de
manière générale, ne travaillez pas sur le matériel du point d’accès MP lorsqu’il
y a un risque de foudre.
Aviso No conecte ni desconecte cables, ni tampoco trabaje con el hardware
del punto de acceso de MP durante una tormenta eléctrica.
Translated Warning Conventions and Warnings
67
Appendix C
68
Trapeze Mobility Point Installation Guide
Index
access point. See MP (Mobility Point)
activating an MP 50
advisory notices, explanations of 4
ANT-1060 10
ANT-1120 10
ANT-1180 10
ANT-5060 10
ANT-5120 10
ANT-5180 10
antennas, external 10
documentation conventions 5
documentation, product 2
drop ceiling installation 30
dual-homed connections 9
bracket 12
cable ports 9
cable requirements 20
solid surface 40
Category 5 cables 9
strain relief 40
ceiling installation
drop tiles 30
solid 40
suspended, flush tiles 24
connections
dual-homed 9
external antenna 49
LEDs 51
MX (Mobility Exchange) 50
troubleshooting 53
conventions, text and syntax 5
customer service iii
Ethernet
cable requirements 20
connections to an MX switch, instructions
50
connections to an MX switch, MP port
locations 9
LEDs 51
ports 9
external antenna
connections to an MP, instructions 49
external antennas 10
flush ceiling installation 24
hardware
bottom view 8
features 8
inventory 16
mounting bracket 12
required, list of 22
top view 8
Index
69
health LED
description 13
troubleshooting with 53
verifying MP health with 52
installation
junction box 36
MP 15, 22
requirements 18
requirements, tools 22
solid surface 40
suspended ceilings 30
suspended ceilings, flush tiles 24
tabletop 45
T-bar ceilings. See suspended ceilings
warnings, cables 20
warnings, radio 19
warnings, service 7
warnings, translations 61
IP addresses 59
MAC addresses 59
manuals, product 2
Mobility Exchange. See MX
Mobility Point. See MP
model numbers
external antennas 10
mounting bracket 12
mounting options 12
MP (Mobility Point)
description of 7
installation 15, 22
specifications 55
troubleshooting 53
warnings 61
MX (Mobility Exchange)
connections 14, 50
MP LEDs 51
recommendation 18
network plan, RingMaster 18
junction box installation 36
PoE (Power over Ethernet)
dual-homed connections 9
pin signals 21
specifications 56
use with Trapeze devices only 18
ports 9
product documentation 2
Kensington security slot 12
LEDs 12
health 13, 52, 53
MP (on MX) 51
radio 13
links
dual-homed 9
LEDs 51
MP 51
troubleshooting 53
70
radio LEDs 13
radios
default state 7
health 53
radio LEDs 13
specifications 55
status 13
Trapeze Mobility Point Installation Guide
troubleshooting 53
warnings 19
redundancy 9
requirements 18
cables 20
hardware 22
RingMaster
wall installation recommendations 19
work order 18
RJ-45s 9
wall installation
junction box 36
recommendations 19
solid 40
warnings
cable 20
installation 7
radio 19
translations 61
work order, RingMaster 18
safety notices, explanations of 4
solid surface installation 40
specifications 55
status LEDs. See LEDs
status lights. See LEDs
suspended ceilings, installation
drop tiles 30
flush tiles 24
switch. See MX (Mobility Exchange)
syntax conventions 5
tabletop installation 45
TAC (Technical Assistance Center) iii
T-bar ceilings. See suspended ceilings
Technical Assistance Center iii
technical specifications 55
technical support iii
tools 22
translated warnings 61
Trapeze customer service iii
Trapeze Networks Mobility System 1
troubleshooting 53
universal mounting bracket 12
unpacking an MP 16
Index
71
72
Trapeze Mobility Point Installation Guide

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 78
Page Mode                       : UseOutlines
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:1305293b-d897-4340-82dc-45b633401fc0
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Create Date                     : 2005:03:24 11:47:46Z
Modify Date                     : 2005:03:25 09:56:54+08:00
Metadata Date                   : 2005:03:25 09:56:54+08:00
Creator Tool                    : FrameMaker 7.0
Document ID                     : uuid:e6039cfd-636b-4e8a-bbf4-43dec9e09a01
Format                          : application/pdf
Creator                         : Trapeze Networks Technical Publications
Title                           : Trapeze Mobility Point Installation Guide
Author                          : Trapeze Networks Technical Publications
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QZE200

Navigation menu