Juniper Networks AP41 Premium Ei-Fi & BLE Array AP User Manual Hardware installation guide Rev3
Mist Systems, Inc. Premium Ei-Fi & BLE Array AP Hardware installation guide Rev3
Contents
- 1. User manual.pdf
- 2. User manual
- 3. Users Manual_rev
User manual.pdf
Overview: The Mist AP41 delivers 4x4 MIMO with four spatial streams when operating in multi-user (MU) or single-user (SU) mode that that supports the IEEE 802.11ac Wave 2 specification. Understanding the Product: Included in the box: • AP41 • IoT mating connector • Mounting bracket with mounting hardware I/O ports and Kensington lock Reset USB 12VDC IoT Module Eth1 Eth0+PoE Reset to the factory default settings USB2.0 support interface Support for the 12VDC power supply recommended by Mist 8-pin pin interface for digital input, digital output, analog input, and ground 10/100/1000 BaseT RJ45 interface 10/100/1000 BaseT RJ45 interface 10/100/1000 BaseT RJ45 interface that supports 802.3at PoE PD Mounting kit installation: Technical Specifications: Feature Power options Powering adaptor Dimensions Weight Operating temperature Operating humidity Operating altitude Electromagnetic emissions I/O RF Maximum PHY rate Indicators Compliance standards Description 802.3at PoE 12V/3A DC power supply 100-240VAC, 50-60 Hz, input All regions (output): 12V/3A DC output 215mm x 215mm x 52mm (8.46in x 8.46in x 2.05in) 1.6 kg (3.53 lbs) Internal antenna 0° to 40° C External antenna -20° to 50° C 10% to 90% maximum relative humidity, non-condensing 3,048m (10,000 ft) FCC Part 15 Class B 1 - 10/100/1000BASE-T auto-sensing RJ-45 with PoE 1 – 10/100/1000BASE-T auto-sensing RJ-45 1 – 10/100/1000BASE-T auto-sensing RJ-45 USB2.0 IoT terminal block 12VDC 2.4GHz - 4x4:4 spatial streams 802.11ac MU-MIMO & SU-MIMO 5GHz - 4x4:4 spatial streams 802.11ac MU-MIMO & SU-MIMO 2.4GHz / 5GHz scanning radio 2.4GHz BLE with Dynamic Antenna Array Total maximum PHY rate – 2533Mbps 5GHz – 1733 Mbps 2.4GHz – 800Mbps Multi-color status LED UL 60950-1 CAN/CSA-C22.2 No. 60950-1 UL 2043 FCC Part 15.247, 15.407, 15.107, and 15.109 RSS-247 ICES-003 (Canada) Warranty Information: The AP41 family of Access Points comes with a limited lifetime warranty. Ordering Information: Access Points AP41-US AP41E-US Premium Wi-Fi & BLE Array AP with internal antennas for the US and Canada Regulatory domain Premium Wi-Fi & BLE Array AP with external antenna connectors for the AP41-US-M AP41E-US-M US and Canada Regulatory domain Premium Wi-Fi & BLE Array AP with internal antennas for the US and Canada Regulatory domain – Multi-Pack Premium Wi-Fi & BLE Array AP with external antenna connectors for the US and Canada Regulatory domain – Multi-Pack Mounting brackets AP41BR1 AP41BR2 Premium AP T-bar ceiling mounting bracket kit Premium AP drywall ceiling mounting bracket kit Power Supply options 12V DC supply 100-240VAC, 50-60 Hz, input All regions (output): 12V/3A DC output Regulatory Compliance Information: This product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections as defined by the 802.3at Standard. FCC Requirement for Operation in the United States of America: FCC Guideline for Human Exposure This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 25cm between the radiator & your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. FCC Caution • Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. • This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. • For operation within 5.15 ~ 5.25GHz / 5.47 ~5.725GHz frequency range, it is restricted to indoor environment. • The band from 5600-5650MHz will be disabled by the software during the manufacturing and cannot be changed by the end user. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules. Industry Canada This device complies with RSS-247 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme à la norme CNR-247 d'Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclaration d'exposition aux radiations:Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. IC Caution (i) The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems; (ii) The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall be such that the equipment still complies with the e.i.r.p. limit; (iii) The maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-topoint and non-point-to-point operation as appropriate; and (iv) Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices. Avertissement Le guide d’utilisation des dispositifs pour réseaux locaux doit inclure des instructions précises sur les restrictions susmentionnées, notamment : (i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux; (ii) le gain maximal d'antenne permis pour les dispositifs utilisant les bandes de 5250 à 5 350 MHz et de 5470 à 5725 MHz doit être conforme à la limite de la p.i.r.e; (iii) le gain maximal d'antenne permis (pour les dispositifs utilisant la bande de 5 725 à 5 850 MHz) doit être conforme à la limite de la p.i.r.e. spécifiée pour l'exploitation point à point et l’exploitation non point à point, selon le cas; (iv) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour les bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract Page Mode : UseNone XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : PDFCreator 2.2.1.0 Keywords : Modify Date : 2016:02:15 11:11:20+08:00 Create Date : 2016:02:02 13:29:30+08:00 Creator Tool : PDFCreator 2.2.1.0 Metadata Date : 2016:02:15 11:11:20+08:00 Document ID : uuid:6ebc9fa5-cbc9-11e5-0000-e2550ae62f4e Instance ID : uuid:76345270-fec8-4797-9acd-646c7b4a7a8b Format : application/pdf Title : Hardware installation guide - Rev3 Creator : melchen Description : Page Count : 7 Page Layout : SinglePage Subject : Author : melchenEXIF Metadata provided by EXIF.tools