INTRODUCTION

CONTROLS,
INDICATORS AND
CONNECTORS
BASIC SYSTEM
CONNECTIONS AND
ADJUSTMENTS

POWER SUPPLY

PREPARATIONS

SETTING AND
ADJUSTMENTS
BEFORE SHOOTING

DV CAMCORDER

SHOOTING
OPERATION

GY-DV500

PLAYBACK MODE

INSTRUCTIONS

TIME CODE
OPERATION

S.S.F. (Super Scene
Finder)

yyy
,,,
,,,
yyy

USING EXTERNAL
COMPONENTS

SETUP MENU

FEATURES OF THE
CAMERA SECTION

OTHERS

* The illustration shows the GY-DV500 DV Camcorder with the optional lens viewfinder attached.
Thank you for purchasing this JVC product. Before operating
this unit, please read the instructions carefully to ensure the
best possible performance.
For Customer Use :
Enter below the Serial No. which is located on the body.
Retain this information for future reference.

This instruction manual is made from 100% recycled paper.

Model No. GY-DV500
Serial No.
SC96874-003

IMPORTANT SAFEGUARDS
1.
2.
3.
4.
5.
6.
7.

8.

9.

10.

11.

12.
13.
14.
15.
16.
17.

18.

19.

2

Read all of these instructions.
Save these instructions for later use.
All warnings on the product and in the operating instructions should be adhered to.
Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners.
Use a damp cloth for cleaning.
Do not use attachments not recommended by the appliance manufacturer as they may cause hazards.
Do not use this appliance near water – for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet
basement, or near a swimming pool, etc.
Do not place this appliance on an unstable cart, stand, or table. The appliance may fall, causing serious injury to a child or adult, and serious damage to the appliance.
Use only with a cart or stand recommended by the manufacturer, or sold with the appliance.
Wall or shelf mounting should follow the manufacturer’s instructions, and should use a mounting
kit approved by the manufacturer.
An appliance and cart combination should be moved with care. Quick stops, excessive force,
and uneven surfaces may cause the appliance and cart combination to overturn.
Slots and openings in the cabinet and the back or bottom are provided for ventilation, and to
insure reliable operation of the appliance and to protect it from overheating, these openings
must not be blocked or covered. The openings should never be blocked by placing the appliance on a bed, sofa, rug,
or other similar surface. This appliance should never be placed near or over a radiator or heat register. This appliance
should not be placed in a built-in installation such as a bookcase unless proper ventilation is provided.
This appliance should be operated only from the type of power source indicated on the marking label. If you are not
sure of the type of power supplied to your home, consult your dealer or local power company. For appliance designed
to operate from battery power, refer to the operating instructions.
This appliance system is equipped with a 3-wire grounding type plug (a plug having a third (grounding) pin). This plug
will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the
outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding
plug.
For added protection for this product during a lightning storm, or when it is left unattended and unused for long
periods of time, unplug it from the wall outlet and disconnect the antenna or cable system. This will prevent damage
to the product due to lightning and power-line surges.
Do not allow anything to rest on the power cord. Do not locate this appliance where the cord will be abused by
persons walking on it.
Follow all warnings and instructions marked on the appliance.
Do not overload wall outlets and extension cords as this can result in fire or electric shock.
Never push objects of any kind into this appliance through cabinet slots as they may touch dangerous voltage points
or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the appliance.
Do not attempt to service this appliance yourself as opening or removing covers may expose you to dangerous
voltage or other hazards. Refer all servicing to qualified service personnel.
Unplug this appliance from the wall outlet and refer servicing to qualified service personnel under the following
conditions:
a. When the power cord or plug is damaged or frayed.
b. If liquid has been spilled into the appliance.
c. If the appliance has been exposed to rain or water.
d. If the appliance does not operate normally by following the operating instructions. Adjust only those controls that
are covered by the operating instructions as improper adjustment of other controls may result in damage and will
often require extensive work by a qualified technician to restore the appliance to normal operation.
e. If the appliance has been dropped or the cabinet has been damaged.
f. When the appliance exhibits a distinct change in performance – this indicates a need for service.
When replacement parts are required, be sure the service technician has used replacement parts specified by the
manufacturer that have the same characteristics as the original part. Unauthorized substitutions may result in fire,
electric shock, or other hazards.
Upon completion of any service or repairs to this appliance, ask the service technician to perform routine safety
checks to determine that the appliance is in safe operating condition.

SAFETY PRECAUTIONS
FOR USA AND CANADA
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN

AUTION :

TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE.
This unit should be used with 12V DC only.
CAUTION:
To prevent electric shocks and fire hazards, do NOT use
any other power source.
NOTE:

The lightning flash with arrowhead symbol, within an
equilateral triangle is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the
product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in
the literature accompanying the appliance.

INFORMATION FOR USA
INFORMATION
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmfull interfrence to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
● Consult the dealer or an experienced radio/TV technician for help.
CAUTION
CHANGES OR MODIFICATIONS NOT APPROVED BY JVC
COULD VOID USER’S AUTHORITY TO OPERATE THE
EQUIPMENT.

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS : (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION

The rating plate (serial number plate) is on the top frame.

CAUTION
To prevent electric shock, do not open the cabinet. No user serviceable parts inside. Refer servicing to qualified service personnel.

AVERTISSEMENT :
POUR EVITER LES RISQUES D’INCENDIE OU
D’ELECTROCUTION, NE PAS EXPOSER
L’APPAREIL A L’HUMIDITE OU A LA PLUIE.
Ce magnétoscope ne doit être utilisé que sur du courant
direct en 12V.
ATTENTION :
Afin d’eviter tout resque d’incendie ou d’électrocution,
ne pas utillser d’autres sources d’alimentation électrique.
REMARQUE :
La plaque d’identification (numéro de série) se trouve sur le panneau
arrière de l’appareil.

WARNING ON LITHIUM BATTERY
The battery used in this device may present a fire or chemical burn
hazard if mistreated. Do not recharge, disassemble, heat avobe 100°C
(212°F) or incinerate.
Replace battery with Matsushita Electric CR2032, use of another
battery may present a risk of fire or explosion.
• Dispose of used battery promptly.
• Keep away from children.
• Do not disassemble and do not dispose of in fire.

INFORMATION (FOR CANADA)
RENSEIGNEMENT (POUR CANADA)
This Class B digital apparatus complies with Canadian
ICES-003.
Cet appareil numérique de la Class B est conforme à la norme
NMB-003 du Canada.

3

Thank you for purchasing the DV Camcorder GY-DV500.
These instructions are for GY-DV500U.

This unit is a MiniDV video system format camcorder.
Videocassettes which are not marked with the MiniDV
symbol cannot be used with this unit.
The following phenomena may occur when tapes recorded
on other units (including another GY-DV500) are recorded
or played back on this camcorder.
● The transient section between scenes recorded on other
units and those recorded on this unit may appear
disturbed.
● Digital noise may appear during playback due to tracking
errors.

● This unit records and plays back in the SP mode.
Recording or playback in the LP mode is not possible.
● Due to manufacturing dispersion of tapes, we
recommend not to record pictures within the first 2 to 3
minutes from the beginning of the tape.
● Before recording important scenes, be sure to perform a
test recording and confirm that both video and audio are
recorded correctly.
● Recorded video and audio contents are for private use.
Other use may infringe on the rights of copyright holders.
● JVC cannot assume liabilities that may derive from the
impossibility of normal recording or playback of video or
audio due to malfunction of the camcorder or the
videocassette.

MAIN FEATURES
● Compact, lightweight design
Employment of magnesium die cast has resulted in an
operation-condition weight as low as approximately 5 kg
including lens, viewfinder, battery, and cassette.

● LOLUX for 0.75 lux (F1.4) illumination
Employment of LOLUX mode ensures +33 dB gain. This is
ideal for difficult shooting conditions with almost no
illumination.

● DV high-quality digital format
The 4:1:1, 8-bit, 25 Mbps component digital processing of
the format ensures recording and playback with high picture
quality.

● Multi-Zone Auto Iris Detection Circuit
Multi-zone auto iris detection circuit ensures optimum iris
position even in backlit conditions or when a bright subject
moves in a frame. Switch provided for selecting over or under
level.

● High sound quality thanks to PCM audio
Two types of sampling, 16-bit, 48 kHz sampling and 12-bit,
32 kHz sampling, ensure high-quality digital audio.
● Concentrated LCD display (back-lit)
The concentrated LCD panel shows the time code and CTL
counter, tape remaining time, remaining battery power, audio
levels, VCR section setup menus, hour meter data, and a
variety of warning indications. The display is back-lit to
facilitate viewing in dark locations.
● Time code reader/generator
The built-in time code reader/generator can be used to record
SMPTE time code and user's bits.
● AEF (Automatic Edit Function) enables neat switching
between recorded scenes.
● Built-in monitor loudspeaker for audio checking
The input audio can be monitored in recording or EE mode.
The playback sound can be monitored in the playback mode.
The loudspeaker also outputs an alarm tone in case an
abnormal condition occurs in the unit.
● Rec check function for convenient recording review
● Camera section designed with 3-CCD system for high-quality
picture
Three 1/2" CCDs with 380,000 effective pixels employed.
Digital signal processing for reproduction of DV high-quality
picture.
● Super sensitivity F/11, 2000 lux
2000 lux standard sensitivity increased to F/11 while high S/
N is retained. Enables shooting at normal indoor illumination
eliminating the need for extra illumination.

4

● Safety Zone indication in viewfinder
Three types of safety zone indicator functions provided.
● Zebra pattern video level indication in viewfinder
● Full Auto Shooting (FAS) function
Eliminating the need for troublesome switch or filter
operations, the FAS function automatically provides a wide
range of compatibility with shooting conditions which varies
as you move between indoors and outdoors or between bright
and dark locations.
● Color temperature conversion filters for "3200K", "5600K",
"5600 K + ND" provided.
● Variable scan shutter
Eliminates flicker when shooting other screen pictures than
NTSC, such as computer monitor screens.
Copes with the range from 60.1 Hz to 2084.6 Hz.
● DV (i. LINK) connector
DV connector (4-pin) provided. Enables transfer of digital data
to other equipment provided with DV connector, such as a
non-linear editing controller.
● S.S.F. (Super Scene Finder) function
Enables memorization of the start point and ending point of
each scene or memorization of CUE points.
● 1/2" bayonet type lens
● Camera output, VCR playback output (composite/YC) possible
● External sync input connector
● Built-in color bar (SMPTE type)
● Superior operability with shutter speed and menus selected
by dial.

CONTENTS
BASIC OPERATIONS

INTRODUCTION
MAIN FEATURES ............................................................... 4

5. PREPARATIONS

1. INTRODUCTION

5-1
5-2
5-3

1-1
1-2
1-3
1-4
1-5
1-6
1-7

Main Unit Configuration ..............................................
Precautions for Proper Use ........................................
Routine and Periodical Maintenance .........................
Videocassette to be Used ..........................................
Battery Pack to be Used ............................................
Condensation .............................................................
Characteristic CCD Phenomena ................................

6
7
8
8
9
9
9

2. CONTROLS, INDICATORS AND CONNECTORS
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
2-9

Front Section ............................................................
Right Side Section ....................................................
Left Side Section ......................................................
Top Section ..............................................................
Rear Section ............................................................
Counter Display Contents ........................................
Lens (optional) .........................................................
1.5-Inch Viewfinder (optional) ...................................
Indications in Viewfinder ...........................................
• Warning LED Indicators Inside the Viewfinder .......
• Viewfinder Screen Display .....................................

10
12
18
19
20
22
23
24
25
25
25

PREPARATIONS

Turning the Power ON .............................................. 39
Cassette Loading and Unloading ............................. 40
Setting the Date and Time ........................................ 41

6. SETTING AND ADJUSTMENTS BEFORE
SHOOTING
6-1
6-2
6-3
6-4
6-5

6-6
6-7
6-8
6-9

Camera Settings ......................................................
Viewfinder Adjustment .............................................
External Monitor Adjustment ....................................
Back Focus Adjustment ............................................
White Balance Adjustment .......................................
• White Balance Adjustment .....................................
• Full-Time Auto White Balance (FAW) .....................
Switch Settings of the VCR Section .........................
Audio Input Signal Selection ....................................
Recording Level Adjustment ....................................
Monitoring Audio during Recording ..........................

42
43
43
44
45
45
45
46
47
48
49

7. SHOOTING OPERATION
7-1
7-2
7-3
7-4

Basic Recording Operation ...................................... 50
VCR Save Mode ....................................................... 52
If Unit is Left in Record-Pause (Standby) Mode ....... 52
Checking Recorded Contents in Record-Pause Mode
(Recording Check Function) .................................... 53

3. BASIC SYSTEM CONNECTIONS AND
8. PLAYBACK MODE

ADJUSTMENTS
3-1
3-2
3-3
3-4
3-5
3-6
3-7

Basic System ...........................................................
Attaching the Zoom Lens (optional) .........................
Attaching the Viewfinder ...........................................
Attaching the Microphone (provided) .......................
Attaching the Microphone (optional) ........................
Attaching the Tripod Base (provided) .......................
Inserting and Replacing Backup Lithium Batteries ..

30
31
31
32
32
33
34

8-1
8-2
8-3

Playback Procedure ................................................. 54
Fast-Forward, Rewind .............................................. 55
Search ...................................................................... 55

APPLICATION
9. TIME CODE OPERATION

4. POWER SUPPLY
4-1
4-2

AC Operation ...........................................................
Battery Pack Operation ............................................
• Attaching a Flat Shape Type Battery Pack .............
• Using an Anton-Bauer Battery Pack ......................
• Remaining Battery Power Display/Precautions for
the Battery Pack .....................................................

35
35
36
37
38

9-1
9-2

9-3
9-4

Displaying Time Code ..............................................
Presetting and Recording of Time Code ..................
• Time Code Presetting Procedure ...........................
• Presetting User's Bit Data ......................................
Recording Time Codes in Continuation of
Time Codes Recorded on Tape ...............................
Reproducing Time Codes .........................................

56
56
57
57
58
59

10. S.S.F. (Super Scene Finder) FUNCTION
10-1
10-2
10-3
10-4
10-5
10-6

Explanation of the S.S.F. Function ...........................
How to Use the S.S.F. Function ................................
Deleting S.S.F. Data .................................................
Resetting S.S.F. Data ...............................................
Writing S.S.F. Data to Tape .......................................
Outputting S.S.F. Data ..............................................

60
61
62
62
63
63

5

1.

INTRODUCTION

1-1 Main Unit Configuration
11. USING EXTERNAL COMPONENTS

The GY-DV500 configuration is as shown below.

11-1 Connecting a Video Component with DV Connector 64
11-2 Connecting a PC ...................................................... 65

12. SETUP MENU
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
AUTO IRIS

FULL AUTO BLACK

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

ON

HML
SAVE STBY

VTR

GAIN

CAM
AUTO KNEE BARS
OFF

66
66
67
68
70
71
72
73
74
75
75
76
77
78

PRST A B

12-1 VCR Setup Menu .....................................................
• VCR Setup Menu Configuration .............................
• Displaying and Setting VCR Setup Menus .............
• VCR Setup Menu Contents ....................................
12-2 Camera Menu Screen Flow .....................................
12-3 How to Select from the Camera Menu .....................
12-4 VF Display Screen ...................................................
12-5 OPERATION Screen ................................................
12-6 PROCESS Screen ...................................................
12-7 ADVANCED PROCESS Screen ...............................
12-8 SKIN COLOR ADJUST Screen ................................
12-9 FILE MANAGE Screen .............................................
12-10 SETUP Screen .........................................................
12-11 Resetting of Camera Menu Setting Values ..............

BAL
OUTPUT WHT.

POWER

NG
ON

OFF

Camcorder (GY-DV500)

13. FEATURES OF THE CAMERA SECTION
13-1 Full-Time Auto White Balance (FAW) .......................
13-2 IRIS (Brightness) Adjustment ...................................
• Adjustment of Lens Iris ..........................................
• Zebra Pattern Display during Manual Adjustment ......
13-3 Shooting the Screen Image on a Computer Monitor
13-4 Gain (Sensitivity) Adjustment ...................................
• Gain Switching .......................................................
• Gain Boost under LOLUX Condition ......................
13-5 Switch Setup According to Illumination and Subject
• Switch Functions ....................................................
• Full Auto Shooting (FAS) Function .........................
13-6 How to Use Skin Detail ............................................

79
80
80
80
81
82
82
82
83
83
83
84

2
203
CR V
3

Lithium battery
Microphone

Head cleaning tape

OTHERS
Tripod base

14. OTHERS
14-1 Troubleshooting ........................................................
• Alarm Indications ...................................................
• Warnings in Viewfinder ...........................................
• Troubles with Error Code Outputs ..........................
• Troubles without Error Code Outputs .....................
14-2 Hour Meter Display ..................................................
14-3 Specifications ...........................................................
• Optional Accessories .............................................
• External Dimensions ..............................................

6

86
86
88
90
91
92
93
94
94

CAUTION :
● The front base mount may be locked while the pin of the
tripod base is not inserted into the hole on the rear base
mount of the unit. Therefore, after mounting, make sure
that these parts are engaged properly.
● When moving the GY-DV500 mounted on a tripod, any
impact or vibration should be avoided as this may cause
the unit to become detached and to drop from the tripod.
Be sure to remove the unit from the tripod before
transporting it.

1. INTRODUCTION

1-2 Precautions for Proper Use
● Supply voltage
Make sure that the power is between 11 V and 15 V DC. If
the power voltage is too low, abnormal color and increased
noise may occur. Do not exceed 15 V DC in any case, or the
unit could be damaged.
● Allowable ambient temperature and humidity
Be sure to use the unit within the allowable temperature range
of 0°C to 40°C and a relative humidity of 30% to 80%. Using
the unit at a temperature or humidity outside the allowable
ranges could result not only in malfunction but the impact on
the CCD elements could be serious as small white spots
may be generated. When storing the GY-DV500 for a long
time, the storage temperatures should be -20°C to 60°C.
● Strong electromagnetic waves or magnetism
Where there are strong electromagnetic waves or magnetism,
for example near a radio or TV transmitter, transformer, motor,
etc., the picture may contain noise and the colors may be
incorrect.
● Use of wireless microphone near the camera
When a wireless microphone or wireless microphone tuner
is used near the camera during recording, the tuner could
pick up noise.
● Avoid using or placing the unit in places;
• subject to extreme heat or cold;
• with excessive dirt or dust;
• with high humidity or moisture;
• subject to smoke or vapour such as near a cooking stove;
• subject to strong vibrations or on an unstable surface.
• also do not leave the unit for long hours in a parked car
under direct sunlight or near room heating equipment.
● Protect the unit from being splashed with water (especially
when shooting in the rain).
● Protect the unit from being wet when shooting on a beach.
In addition, salt and sand may adhere to the camera body.
Be sure to clean the camera after use.
● Protect the unit against penetration of dust when using it in a
place subject to sandy dust.
● Optical performance of lens
Due to the optical performance of the lens, color divergence
phenomena (magnification chromatic aberration) may occur
at the periphery of the image. This is not a camera
malfunction.

● Setup level
The video signal of the unit's video output is provided with a
setup level when shipped from the factory. If you want to turn
OFF the setup level, please consult the person in charge of
professional video equipment at your nearest JVC-authorized
service agent. The setup level is never attached to the video
signal recorded on the tape.
● Use the unit in an upright position.
If placed on its side, heat release efficiency will deteriorate,
adversely affecting the tape transport. Depending on
circumstances the tape may also be damaged.
● Vibrations
Colors may fail to appear during VCR playback in locations
subjected to vibrations.
● Precautions for transportation
Do not drop or hit the unit against a hard object.
● Remove the videocassette before transporting the unit.
● Do not insert an object other than a videocassette in the
cassette insertion slot. Be sure to close the cassette cover
when the unit is not to be used for a long period
● Do not set the POWER switch to OFF or remove the power
cable during recording or playback. Otherwise the tape may
be damaged.
● When the unit is not in use, be sure to set the POWER switch
to OFF in order to reduce power consumption.
● Cleaning the body: Wipe body with a dry, soft cloth. When it is
extremely dirty, soak the cloth in a solution of neutral
detergent, wring it out and then wipe. To prevent deformation
of the body, etc. and to avoid operation hazards, do not allow
volatile liquids such as benzine and thinner to touch the body,
and do not wipe it with a cloth soaked in such a liquid.
● The camera may be unstable in the period immediately after
the power is turned on, but this is not a malfunction.
● If a tape containing recorded PAL signals is played back, the
GY-DV500 automatically enters the STOP mode. If this
happens, remove the videocassette so that the unit returns
to its normal state.

● Noise may appear in the viewfinder when switching between
the playback picture and the EE picture.

CAUTION :
● Do not point the lens or viewfinder directly at the sun or other strong light source.
• Eye damage could result.
• If the lens or viewfinder is left pointed at the sun, rays may collect inside the unit and cause damage or a fire.
● When carrying the camera, be sure to hold the carrying handle. Holding the lens or viewfinder may result in damage.

7

1. INTRODUCTION

1-3 Routine and Periodical Maintenance
The GY-DV500 incorporates precision mechanical parts, which will collect dirt, wear out and deteriorate as the unit is used. On the
other hand, when the unit has been used for a long period in a normal environment, the heads, drums and tape transport mechanisms
also collect dirt deposited on them. Furthermore, dust which penetrates the inside of the VCR section especially during outdoor use
will promote the wear and deterioration of mechanical parts by causing poor contact between tape and heads or failing to maintain
the video and audio quality at high levels. To prevent wear and deterioration, clean the mechanical parts using a head cleaning tape
as routine maintenance. However, cleaning with a head cleaning tape alone is not enough for cleaning the entire tape transport
mechanism, it is also recommended to apply periodical maintenance (inspection) to prevent troubles that may be caused by the
sudden occurrence of failure. As the replacement, adjustment and servicing of parts require advanced skill and equipment, please
consult the person in charge of professional video equipment at your nearest JVC-authorized service agent.

Head Cleaning

Periodical Maintenance

● To maintain beautiful pictures and sound, be sure to use a
head cleaning tape to clean the head periodically. (Read the
separate sheet “Precautions for Use of Head Cleaning Tape”.)
If head cleaning is not performed periodically, a type of mosaic
noise called block noise may appear in the picture or sound
may be interrupted.

Contents : Check or replace the following mechanical parts
according to the running time.
Running Time
Drum ass’y (including heads)
Head cleaner
Tape guides & rollers
Rotary encoder
Belts & gears
Drive parts

500H
V
>
V
–
>
V

1000 H
V
v
>
>
v
V

1500H
V
>
>
–
>
>

2000H
v
v
v
v
v
v

V: Clean, check and adjust.
>: Clean and check. Replace as required.
v: Replace.

Block Noise
● Use the provided head cleaning tape. Do not use head
cleaning tapes other than specified. For instructions on how
to use the head cleaning tape and precautions for its use,
read the separate sheet “Precautions for Use of Head
Cleaning Tape”.
● When dirt adheres to the heads of the GY-DV500, the
following indications appear during playback and recording
check using the RET button on the lens section.
• “RF” appears on the display panel.
• “HEAD CLOG” appears on the counter display.
• “VTR WARNING (HEAD)” appears in the viewfinder.
● If this kind of indication appears, please stop the recording.
Head cleaning is required. This indicator disappears when
the POWER is turned OFF, or when the cleaning tape is
played back.
"RF" indicator
CH 1
40 30

CH 2
32k
AUD LOCK

20

10

OVER
0 dB
OVER

• The maintenance contents vary depending on the operating
environment and method. Therefore, the above data should be
considered as a reference.

Time management
The accumulated running time of the unit can be confirmed
with the hour meter display (which shows the accumulated drum
running time). For details, see "HOUR METER DISPLAY" on
page 92.
For consultations related to the maintenance programming
or cost, please contact the person in charge of professional
video equipment at your nearest JVC-authorized service
agent.

RF

48k

SP

MENU

"HEAD CLOG" indicator

1-4 Videocassette to be Used

8

● Use JVC’s videocassette tapes marked with MiniDV for
this unit.
Please use DVM60 or DVM30 type videocassettes.
● Videocassettes cannot be used upside down.
● Avoid storing a videocassette with unevenly wound tape,
as this may damage the tape. Rewind it to the beginning
before placing a cassette into storage.
● Store videocassettes in a place with little humidity and good
ventilation where mould does not form.
● After a videocassette tape has been used repeatedly,
it becomes unable to maintain full performance due to
an increase in noise caused by dropouts, etc. Do not
continue to use a dirty or damaged tape, as this will
reduce the rotary head life.
● Note that if an ME80 videocassette is used at low
temperatures, block noise tends to occur due to head
contamination.

● Videocassette tapes marked MiniDV are provided with
a switch on the back for use in preventing accidental
erasure.
● Slide the switch to SAVE to protect the required recording
in the tape from being overwritten.
● To record on the tape, slide the switch to REC.
Switch
REC
SAVE

1. INTRODUCTION

1-5 Battery Pack to be Used
The GY-DV500 can use any of the following battery packs.
● Flat shape type
● Anton-Bauer battery pack: Trimpack 13/14 Series
Magnum 13/14 Series
Compack 13/14 Series
Propack 13/14 Series

* An Anton-Bauer battery pack cannot be connected directly
to the camera. It is necessary to mount the optional battery
holder.
● Battery holder: Anton-Bauer QRQ27
For details on how to mount the battery holder, see page
37.

To display the remaining battery power accurately, set the
VCR Setup Menu item No. 396 BATTERY TYPE according
to the type of the battery pack in use. (See page 69)

1-6 Condensation
● If the unit has been cooled down in a cold place and is then
carried to a warm place, the moisture contained in the warm
air may adhere to the head drum or tape guides and be cooled
into water droplets. This phenomenon is referred to as
condensation (dewing). When this occurs, the head drum and
tape guides are covered with droplets allowing the tape to be
stuck to them, leading to tape damage.
● Condensation occurs in the following cases:
• When the unit is suddenly
moved from a cold place to a
Head drum
warm place.
• When a room heater has just
star ted or when the unit is
exposed directly to cold air from
an air conditioner.
Video tape
• When the unit is placed in a very
humid place.

● When condensation occurs in this unit, the DEW indicator
on the display lights up, and the WARNING LED blinks red.
(See page 86)
To remedy, leave the unit with the power ON and wait until
the WARNING LED stops blinking red and the DEW indicator
disappears from the counter display.

DEW
indicator

OPERATE/WARNING
CH 1
40 30

CH 2
32k
AUD LOCK

20

48k

10

OVER
0 dB
OVER

PB

AUTO OFF DEW
NDF

HOLD

SP

MENU

Do not leave the videocassette inserted when moving the
camera under conditions where the temperature
environment changes.

1-7 Characteristic CCD Phenomena
Smear and Blooming

Moire or Aliasing

Due to the physical structure of a CCD it is possible to induce
vertical streaking (called "smear") when shooting an extremely
bright light source. Another effect is the expansion of light around
a bright light or object (called "blooming").
The CCD employed in this unit is characterized by inducing
very little smear or blooming. Nevertheless, please be careful
when shooting a bright light source.

Shooting stripes or fine patterns may cause a jagged effect or
a banding in fine mesh patterns.

Smear
(Vertical pale streaking
appearing at high
luminous object)

White dots
High temperatures can cause CCD sensor pixels to malfunction
with the effect of white dots in the image. This condition is
conspicuous especially when gain is applied.
This is a characteristic of the charged-coupled device (CCD).
As far as possible, use the unit under conditions where the
temperature of the unit does not increase.

High luminous object
(Electric light, sunlight, etc.)

Monitor screen

Blooming
(Blurring in highlight)

9

2. CONTROLS, INDICATORS AND CONNECTORS
2-1 Front Section
4 [LENS] Lens control connector
Connect 12-pin lens control cable from lens.
Pin No.

q
w

!1
VF

!0

Function

Pin No.

Function

1

RET switch

7

IRIS position

2
3
4

VCR trigger
GND
Lens AUTO/MANU control

8
9
10

IRIS A/R INPUT
EXTENDER position
ZOOM position

5
6

IRIS control
+12V DC

11
12

—
—

5 [ZEBRA] Switch

e

OFF
ON

ZEBRA
SKIN
AREA

AUTO
WHITE

o

ACCU
FOCUS

r
t

VTR AUDIO
LEVEL CH-1

TAKE

i
u

y

1 Viewfinder mount base, sliding securing ring
Mount the viewfinder on the base and secure it using the
sliding securing ring.
☞ See "Attaching the Viewfinder" on page 31.

2 [VF] Viewfinder connector (6-pin)
Connect the cable from the viewfinder here.

3 [MIC IN] Microphone input connector (XLR 3-pin)
Balanced 3-pin connector for camera microphone.
• When the camera microphone to be connected is a
phantom microphone or other type of microphone, set
the CAM MIC 48V item on the Camera Setup menu. See
page 77.
• When using a microphone with this connector, set the
AUDIO INPUT switches 7 8 on page 14 to FRONT in
accordance with the audio channel (CH1 or CH2) to be
recorded.
☞ See page 14.
Pin No.

1
3
2

Function

1

GND

2

HOT

3

COLD

CAUTION:
● The provided microphone is a phantom microphone.
Please confirm that the CAM MIC 48 V item on the
Camera SETUP Menu is set to “ON”.
● When using a microphone other than a phantom
microphone, first set the CAM MIC 48 V item to “OFF”
before connecting the microphone. Otherwise the
microphone may be damaged.

10

When this switch is ON, a zebra pattern is superimposed
on the viewfinder areas having video levels with a luminance
level of 70% to 80%. This pattern can be used as a reference
for manual adjustment of the lens iris.
* The zebra patterns are only displayed on the viewfinder
screen. The zebra patterns are not generated for the
MONITOR OUT or Y/C OUT output.
☞ See "Zebra Pattern during Manual Adjustment" on page
80.
• The default value is 70% - 80%. The luminance level can
be changed with the ZEBRA setting in the VF DISPLAY
Menu screen.
☞ See "ZEBRA" item on page 72.
While this switch is pressed to the SKIN AREA side, the
color tone areas specified with the SKIN DTL ADJUST item
on the ADVANCED PROCESS MENU are indicated in the
viewfinder. The switch returns to the OFF position when
released.
☞ See “How to Use Skin Detail” on page 84.
• The Skin Detail color tone areas are not indicated while
the VTR playback picture is shown in the viewfinder.

6 [VTR] VTR trigger button (record start/stop button)
Record start/stop can be effected with this button.
(It is interlocked with the VTR trigger button on the lens
section.)

7 [AUDIO LEVEL CH-1] CH-1 recording level control
Adjusts the recording level of the CH1 audio signal input.
Normally, the camera is used with the control set to the
maximum (10) position.
• To use this control, set the VCR Setup Menu item No.
246 FRONT VOLUME ENABLE to "ENABLE".
Note:
Even when the VCR Setup Menu item No. 246 is set to
DISABLE, the recording level changes slightly when this
control is turned.

8 [AUTOWHITE./ACCU FOCUS] switch
AUTO WHITE:
• First, position a white object to occupy 80% of the centre
of the image.
• Setting this switch to the upper position ("AUTO WHT")
will provide automatic adjustment for white balance.
* It is not activated in preset, full auto shooting, full-time
auto white balance and color bar modes.
☞ See "White Balance Adjustment" on page 45.

2. CONTROLS, INDICATORS AND CONNECTORS

2-1 Front Section (Cont’d)
ACCU-FOCUS:
• When this switch is set to "ACCU FOCUS" in the lower
position, the lens iris will be forced to open for
approximately ten seconds.
• The depth of field can be reduced and the lens focusing
can be adjusted more accurately.
CAUTION:
• As the automatic shutter is activated here, flicker may
appear on the screen depending on the lighting
conditions (such as a fluorescent lamp, etc.)
• This operation is not possible in the LOLUX mode.

9 [TAKE] button
The Super Scene Finder (S.S.F.) function retains the time
code data for IN point and OUT point or CUE point in the
unit's memory.
☞ See “S.S.F. Function on” page 60.

0 Lens mounting ring/Lens lock lever
Hold the lens and use the lever to turn the ring anticlockwise
to release lens.
To mount lens make sure the lens guide pin fits well, and
then turn the ring clockwise until firm.
☞ See "Attaching the Zoom Lens" on page 31.

! [FILTER] Color temperature conversion filter
control knob
This knob changes the internal color temperature filter.
☞ See "Camera Settings" on page 42.

11

2. CONTROLS, INDICATORS AND CONNECTORS

2-2 Right Side Section
[Camera Setting Section]

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

AUDIO CH-2
LEVEL

LOLUX

GAIN

B
PRST A

HML

STRETCH
NORMAL
COMPRESS

OFF ON
AUTO KNEE

AUTO IRIS

VTR

A
B
C

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

BARS CAM

8
9
0

OPERATE/WARNING
RESET

SAVE STBY

1
2
3
4
5
6
7

T.BAL
OUTPUT WH

POWER

NG
ON

OFF

D

1 [ALARM] Volume control
Turn to adjust the volume of the alarm tone that is output
from the monitoring loudspeaker or earphone in case of a
warning or other abnormal condition occurring with the GYDV500.
Turn this control anticlockwise to reduce the volume. Setting
this control to the minimum position mutes the alarm tone.

2 [MONITOR] Audio monitor volume control
Adjusts the volume of the monitoring loudspeaker and
earphone. The audio is muted when this control is set to
the minimum position.

3 [STATUS] Status/menu button
Pressing this button in the normal screen mode (condition
when menu is not shown) displays a status screen in the
viewfinder. The displayed status mode changes each time
the button is pressed.
☞ See "Status Screens" on page 25.
Pressing this button for more than 1 second in the normal
screen mode displays the Camera Menu screen in the
viewfinder. Pressing this button while the menu screen is
displayed in the viewfinder makes the menu screen
disappear.
☞ See “How to Select from the Camera Menu” on page 71.

4 [SHUTTER/MENU] dial
• Pressing this dial once in the normal screen mode
(condition when menu is not shown) displays the shutter
speed for approximately 5 seconds. When this dial is
turned upwards while the shutter speed is displayed, the
shutter speed becomes slower. When turned downwards,
the shutter speed becomes faster. The selected shutter
speed is memorised for each file. To return the memorised
shutter speed to the factory preset, press the dial one
more time while the shutter speed is displayed.
• When this dial is turned upwards or downwards while the
menu screen is displayed, the cursor (>) also moves
upwards or downwards to allow selection of items in the
menu. To change the setting value of the item, press this
dial. When the setting value starts blinking, turn this dial
upwards or downwards to change the setting.
☞ See "How to Select Camera Menus" on page 71.

12

5 [LOLUX] LOLUX On/Off button
This button toggles the LOLUX mode on and off.
• LOLUX gain gives extremely low light level sensitivity for
special applications. This will result in an increase of 33
dB (approximately 45 times) in the LOLUX mode.
• LOLUX operation takes priority over normal gain setting.
• If the unit is placed in the LOLUX mode when it is in full
auto shooting mode, the auto level control (ALC) (one of
the full auto shooting functions) will be made inactive, so
that the LOLUX mode is given preference (FAW still
remains active).
☞ See "GAIN BOOST UNDER LOLUX CONDITION" on
page 82.

6 [BLACK] Black stretch/black compression switch
Switches the gain for the dark section of the image.
Set to an appropriate position depending on the video signal
to be shot.
STRETCH
: By stretching the signal only for the dark
section, contrast in the dark portion of the
image is enhanced.
NORMAL
: Standard mode.
COMPRESS : When an entire image is relatively light and
the contrast is low, the gain of the dark
section is compressed to increase the
contrast.

7 [FULL AUTO] Full auto shooting ON/OFF button
and indicator
• This switch toggles the full auto shooting function on and
off.
• The indicator lights when in the full auto mode.
• Full auto shooting combines the auto iris, auto level control
(ALC) to automatically adjust the video signal level and
the white balance to their optimum levels.
• The iris is placed in automatic mode even if the iris mode
switch of the lens is in manual.
• The gain will vary continuously to the maximum of +12 dB.
The shutter speed will vary continuously to the minimum
of 1/240 of a second.
☞ See "Full Auto Shooting (FAS) function" on page 83.

2. CONTROLS, INDICATORS AND CONNECTORS

2-2 Right Side Section [Camera Setting Section]
8 [AUTO IRIS] Auto iris level switch

This switch selects the automatic iris adjustment
reference value according to the condition in which the
camera is used.
BACK. L : Under back light (Opens the iris about 1
step from the standard level.)
NORMAL: Normal condition
SPOT. L : Under spotlight (Closes the iris about 1 step
from the standard level.)
☞ See "SWITCH FUNCTIONS" on page 83.

9 [GAIN] switch

Electronically boosts the light sensitivity when there is
insufficient illumination on the subject. The boosting
level differs depending on the switch position as follows:
(Factory presets)
L : 0 dB (no boosting is applied)
M : 9 dB (boosted to approximately 3 times the original)
H : 18 dB (boosted to approximately 8 times the original)
• The boosting level for each switch position can be
changed with the OPERATION menu screen. (☞ See
page 73.)
The more the boosting level is increased, the more the
resulting image will be noisy.

0 [VTR SAVE/STBY] switch

Used to select the status of the GY-DV500 when the
power is turned ON and a videocassette is loaded.
STBY: The GY-DV500 is in the standby mode.
When a recordable videocassette is loaded, the
GY-DV500 enters the record-pause mode.
SAVE: The GY-DV500 is in the save mode.
• The status of the GY-DV500 is displayed on the Status
screen 1 in the viewfinder.

@ [WHT.BAL] White balance switch

Three white balance modes are selectable with this switch.
B
: If white balance is performed with the
switch in this position, it will be
memorised into B.
A
: If white balance is performed with the
switch in this position, it will be
memorised into A.
PRST (PRESET) : A non-erasable white balance setting at
3200K.
• FAW (Full-time Auto White) mode can be set to A, B or
PRESET with the OPERATION MENU (see page 73).
In the FAW mode, video color temperatures are constantly
sampled for automatic adjustment to a proper white
balance.

# [NG] button
Pressing this button while recording or in the record-pause
mode deletes the S.S.F. data stored in the memory of the
GY-DV500 with the S.S.F. (Super Scene Finder) function.
This function is only valid in the MARK mode.
☞ See "S.S.F. (Super Scene Finder) Function" on page 60.

$ [POWER] switch

Turn the power ON and OFF with this switch.
When this switch set to ON while a videocassette is loaded,
the GY-DV500 status differs depending on the setting of
the VTR (SAVE/STBY) switch 0.

! [OUTPUT] Color bar/Camera/Auto knee switch

This switch is used to select the output signal. When
the video signal from the shooting camera is selected,
the auto knee function is available.
CAM. AUTO KNEE ON:
Outputs the video signal from the shooting
camera. In this mode, the auto knee function is
available.
CAM. AUTO KNEE OFF:
Outputs the video signal from the shooting
camera. In this mode, the auto knee function is
not available.
BARS: Outputs the color bar signal. In this mode, the
auto knee function is not available. Set to this
position when adjusting the video monitor or
when recording the color bar signal.
AUTO KNEE function
When shooting a foreground subject, such as a human
being, etc., with a high-brightness background, if the
brightness level is set for the foreground subject, the
background image will be blurred with white. In such a
case, a clearer background is obtained when the auto
knee function is used.
It is effective especially in the following cases:
• When shooting a human being indoors with a view
to the landscape out through a window.
• When shooting a human being in the shade on a
fine day.
• When shooting a high-contrast scene.
CAUTION:
If a fast moving high-brightness section like a car
in sunlight is shot, the auto knee function may
change the brightness of the entire image along
with the motion of the object. In this case, set the
auto knee function to OFF.

13

2. CONTROLS, INDICATORS AND CONNECTORS

2-2 Right Side Section (Cont'd)
[Audio Setting Section]

t

y

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

r

AUTO
MANUAL

AUDIO SELECT
AUDIO INPUT
CH-1

SHUTTER STATUS

CH-1

MONITOR

AUDIO CH-2
LEVEL

CH-2
FRONT
REAR

MENU
CH-1 AUDIO CH-2

LEVEL
FULL AUTO BLACK

GAIN

B

u

PRST A

HML

BARS CAM

SAVE STBY

VTR

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

BAL
OUTPUT WHT.

ON

OFF

q

w e

1 Monitoring loudspeaker
• Enables EE monitoring of the input audio signal during
recording, in the record-pause mode or in the stop mode.
Outputs the playback sound in the playback mode.
The sound to be output can be selected using the
MONITOR SELECT switch 4.
• The loudspeaker volume can be adjusted with the
MONITOR volume control 2 on page 12.
The audio from the loudspeaker is not output when an
earphone is plugged into the EARPHONE jack 2 on page
20. The warning alarm tones are also output through this
loudspeaker.
☞ See “ALARM INDICATIONS” on pages 86.

2 [CH1 AUDIO LEVEL] CH1 recording level control
Adjust the recording level of the CH1 audio channel with
this control.
• To use this control, set the CH1 AUDIO SELECT switch
5 to “MANUAL”.
This control works regardless of the setting of the VCR
Setup Menu item No. 246 FRONT VOLUME ENABLE.
To use this control, set the AUDIO LEVEL CH-1 recording
level control (7 on page 10) on the front section to the
maximum (10) position, or set the VCR Setup Menu item
No. 246 FRONT VOLUME ENABLE to “DISABLE”.

3 [CH2 AUDIO LEVEL] CH2 recording level control
Adjust the recording level of the CH2 audio channel with
this control.
• This control is valid only when the CH2 AUDIO SELECT
switch 6 is set to "MANUAL".

4 [MONITOR SELECT] audio monitor selector
switch
This switch is used to select the monitor sound output from
the MONITORING LOUDSPEAKER 1 or via the
EARPHONE jack 2 on page 20.
CH-1 : The CH1 channel audio is output.
MIX : CH1 and CH2 channel audio are output mixed.
CH-2 : The CH2 channel audio is output.
CAUTION:
Make sure to move switches all the way. Do not leave a
switch stopped in a midway position. Noise will be
generated and operation irregularities will occur.

14

i

POWER

NG

5 [CH-1 AUDIO SELECT] selector switch
This switch is used to select the method for adjusting the
recording level of the CH-1 audio channel.
AUTO
: The recording level is held at the reference level
even when sounds greater than the reference
level are input.
The recording level does not increase when the
input level is low.
MANUAL: The recording level can be adjusted with the CH1 AUDIO LEVEL control 2 or the CH-1 AUDIO
LEVEL control 7 on page 10.
To use the AUDIO LEVEL CH-1 recording level
control on the front section, set the VCR Setup
Menu item No. 246 FRONT VOLUME ENABLE
to “ENABLE”.

6 [CH-2 AUDIO SELECT] selector switch
This switch is used to select the method for adjusting the
recording level of the CH-2 audio channel.
AUTO
: The recording level is held at the reference level
even when sounds greater than the reference
level are input.
The recording level does not increase when the
input level is low.
MANUAL: The recording level can be adjusted with the CH2 AUDIO LEVEL control 3.

7 [CH-1 AUDIO INPUT] selector switch
This switch is used to select the input section of the CH1
audio channel.
FRONT : The sound from the MIC IN connector on the
front side section is input.
REAR : The sound from the CH-1 AUDIO IN connector
on the rear side section is input.

8 [CH-2 AUDIO INPUT] selector switch
This switch is used to select the input section of the CH2
audio channel.
FRONT : The sound from the MIC IN connector on the
front side section is input.
REAR : The sound from the CH-2 AUDIO IN connector
on the rear side section is input.

2. CONTROLS, INDICATORS AND CONNECTORS

2-2 Right Side Section (Cont'd)
[VCR Setup Block]

u
CH-1

AUDIO
LEVEL

CH-2
CH-1

OPERATE/WARNING
ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

PRESET
REGEN

AUDIO SELECT
AUDIO INPUT

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

TC GENERATOR

CH-2
AUTO
MANUAL

LIGHT
RESET

CH-1

i

CH-2

FREE
REC

CONTINUE

MENU

FRONT
REAR

MONITOR

LITHIUM BATT.
MENU

GROUP

ITEM

HOLD

SHIFT

SELECT

DATA SET

ADVANCE PRESET

CH-1 AUDIO CH-2

LEVEL
FULL AUTO BLACK

GAIN

B
PRST A

HML

BARS CAM

SAVE STBY

VTR

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

BAL
OUTPUT WHT.

o

POWER

NG
ON

OFF

1 [MENU] button
Press this button to enter the VCR setup menu mode.
When the VCR setup menu mode is engaged, the "MENU"
indicator in the LCD display lights and the counter display
and viewfinder display are changed to the menu indication.
In the VCR setup menu mode, pressing this button resumes
the normal mode.

2 [HOLD/GROUP] button
• Press this button when presetting the time code or user's
bit. The presently displayed data is held (the "HOLD"
indicator lights on the display) and the leftmost digit of
the counter blinks. Pressing this button during presetting
of time code or user's bit cancels the operation and recalls
the previous display contents.
• In setup menu mode, this button is used to select the
menu group.

3 [SHIFT/ITEM] button
• During presetting of time code or user's bit, press this
button to select the digit to be set. Each press of the button
shifts the digit to be set (which blinks) to the right.
• In setup menu mode, this button is used to select the
menu item.

4 [ADVANCE/SELECT] button
• During presetting of time code or user's bit, press to select
the value of the digit to be set. Each press of the button
increases the number by 1.
• In setup menu mode, this button is used to select the
value of a menu item.

5 [PRESET/DATA SET] button
• During presetting of time code or user's bit, press to save
the set value in the preset memory. The set time code or
user's bit will be preset in the time code generator.
• In setup menu mode, this button is used to confirm the
menu item setting and save the data in the memory.
• For details of the presetting of time code or user's
bit, see page 56.
• For details on the setup menus, see page 67.

w e r t
y q

6 [CONTINUE] button
If this button is pressed simultaneously with the LOG button
8 on page 19 during the stop mode, the tape winds to the
last S.S.F. data OUT point.
☞ See “Scene End Cue Up Function” on page 63.

TIME CODE GENERATOR setting switches

7 [PRESET/REGEN] switch
Toggles the time code generator mode between PRESET
and REGEN.
PRESET: Preset mode. Set to this position when newly
presetting and recording the time code.
REGEN : Regeneration mode, in which the unit reads
existing time codes on the tape and records time
codes in continuation of the existing ones. Set to
this position when you want to add additional time
codes to time codes already recorded on the
tape.

8 [REC/FREE] run switch
Selects the time code running mode while the time code
generator is in preset mode. This switch is not effective in
the REGEN mode.
REC
: The time code runs only during recording. This
position allows you to record continuous time
codes when recording scenes one after another.
FREE : The time code runs permanently.
* If this position is used when recording scenes one after
another, the time codes become discontinuous at the
change points between scenes.

9 Lithium Battery Installation Compartment
Install a lithium battery (CR2032) in this compartment. The
battery is used for the backup of the time code and time
date. The GY-DV500 is delivered without the battery
installed.
The provided lithium battery is for test use. It is recommended
to install a new lithium battery. A new lithium battery can
power the backup for about one year. See "How to Replace
Backup Lithium Batteries" on page 34.

15

2. CONTROLS, INDICATORS AND CONNECTORS

2-2 Right Side Section (Cont'd)
[VCR Display Section]

21

6

5

F

CH 1
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

40 30

3

MONITOR

4

MENU

7
8

CH 2
32k
AUD LOCK

20

OVER
0 dB
OVER

10

48k

PB

E

AUTO OFF DEW
SERVO RF L i
NDF

HOLD

SP

MENU

H

M

REMAIN

REV FWD

CH-1 AUDIO CH-2

S

F

E BATT F

LEVEL
FULL AUTO BLACK

BAL
OUTPUT WHT.

A

9 0

B

C

D

POWER

NG
ON

OFF

1 [OPERATE/WARNING] indicator
Normally lights green.
Lights orange during the VTR SAVE (tape protect) mode.
This indicator lights or blinks in red in the case of a warning
condition related to the remaining tape time, remaining
battery power or other abnormal condition in the unit.
For details, see "ALARM INDICATIONS" on pages 86.

2 [RESET] button
• Press to reset the CTL counter value.
• Pressing the button during presetting of time code or
user's bit resets the time code or user's bit data to
"00:00:00:00".

3 [LIGHT] switch
Turns the illumination of the back-lit display ON or OFF.
ON : The display is illuminated.
OFF : The display is not illuminated.
(Keep this switch at OFF during battery operation of the
GY-DV500 or when it is required to reduce the power
consumption for some reason.)
Note:
When a videocassette is loaded and the VTR switch is
set to SAVE mode, the illumination will go out even if the
backlight is ON.

4 [COUNTER] switch
Selects the contents displayed on the LCD counter display.
The displayed contents when TC or UB is set can be
selected using the VCR Setup Menu item No. 516 DISPLAY
SELECT.
CTL : Set to this position to display the CTL counter.
TC : Set to this position to display time codes or for
presetting the time code. (When the Menu item No.
516 DISPLAY SELECT is set to “TC”.)
Time (Hour, Min., Sec.) is displayed. (When the Menu
item No. 516 DISPLAY SELECT is set to “CLOCK”.)
UB : Set to this position to display the user's bits of time
codes or presetting the user's bit. (When the Menu
item No. 516 DISPLAY SELECT is set to “TC”.)
Date (Month, Day, Year) is displayed. (When the Menu
item No. 516 DISPLAY SELECT is set to “CLOCK”.)

16

M

B

OFF ON
AUTO KNEE

HML

GAIN

BARS CAM

SAVE STBY

VTR

H

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

PRST A

AUTO IRIS

☞ See “VCR Setup Menu Contents” on page 69.

5 Audio level meters
Show the audio input level of the CH-1 and CH-2 channels
in the record mode or EE mode.
In the playback mode, the meters show the playback audio
level.
"OVER" lights in case of excessive input.
CAUTION:
Immediately after the power is switched ON, the level
meters may fluctuate. This is not a malfunction.

6 32K/48K sampling frequency indication
Indicates whether audio recording or playback occurs with
12-bit, 32 kHz sampling or 16-bit 48 kHz sampling.
• In the recording mode, the sampling frequency is set using
the VCR Setup Menu item No. 245 SAMPLING RATE.
In the playback mode, the indication conforms to the
sampling rate of the recorded sound.

7 [AUD LOCK] indicator
Indicates whether the audio signal is locked to the video
signal during recording and playback.

8 [MENU] indicator
Appears when the MENU button 1 on page 15 is pressed
to select the VCR Setup Menu.

9 SP indicator
Indicates the tape speed in record mode.

0 Cassette indicator
Lights when the unit is loaded with a
videocassette. Blinks during ejection or tape
loading.

! [REMAIN] indicator
The remaining tape time (minutes and seconds) is shown.
For details, see page “Remaining Tape Time Display” on
page 22.

2. CONTROLS, INDICATORS AND CONNECTORS

2-2 Right Side Section (Cont'd)
@ Tape transport direction indicators
REV FWD

One of the indicators lights according to the
tape transport direction.
is displayed in the record-pause
mode and in the still picture mode.

# Remaining Battery Power Display
The 7-dot segment bar display shows the remaining battery
power.
* To display the remaining battery power accurately, set
the VCR Setup Menu item No. 396 BATTERY TYPE
according to the type of the battery pack in use.
☞ See "Remaining Battery Power Display" on page 22.

$ Counter display
• Usually, this section shows the data of the CTL counter,
time code or user's bit. The display mode can be selected
with the 4 COUNTER switch.
• Displays the VCR setup menu data when the GY-DV500
is in the VCR setup menu mode by pressing the MENU
button 1 on page 15. The VCR setup menu includes the
hour meter (accumulated drum operating time).
• This section shows an error code when an abnormal
condition occurs with the unit.
☞ See "Counter Display Contents" on page 22.
☞ See "TROUBLES WITH ERROR CODE OUTPUTS"
on page 90.

% Section for time code related indications

n [PB] Time code playback indicator
Lights when the time code is in playback mode.
n [NDF] Non-drop frame indicator
Lights when the internal time code generator or the
playback time code framing mode is non-drop frame. “DF”
is displayed in the drop-frame mode.
• It never lights when the CTL counter is displayed.

^ Warning indicators

n [AUTO OFF] indicator
Lights when a non-recoverable error (e.g. tape winding
error, drum stopped, etc.) occurs with the unit. This
indicator also lights if condensation occurs.
☞ See "TROUBLES WITH ERROR CODE OUTPUTS"
on page 90.
n [DEW] indicator
Lights when condensation (dewing) occurs on the drum
or other mechanism in the unit.
The unit rejects all operations while this indicator is lit.
When the condensation has disappeared, the indicator
turns off and the unit accepts operations again.
n [SERVO] indicator
Lights in the case of trouble with the drum servo during
recording to indicate that normal recording is not being
accomplished.
n [RF] indicator
Lights when the video head is clogged. Head clogging is
detected during playback and recording check using the
RET button on the lens section. Note that it is not detected
during recording.

* Should this indicator light up, clean the head using the
provided head cleaning tape. For instructions on head
cleaning tape, read the separate sheet “Precautions for
Use of Head Cleaning Tape”.
n [Li] Lithium battery indicator
Lights and indicates the necessity of replacement when
the lithium battery that backs up data of the built-in time
code generator is nearly exhausted.
☞ See "How to Replace Backup Lithium Batteries" on
page 34.

n [HOLD] indicator
Lights when the time code generator display is held by
pressing the HOLD button in the time code setting block.
The time code or user's bit can be preset while this
indicator is lit.
☞ See “Displaying Time Code” on page 56.

17

2. CONTROLS, INDICATORS AND CONNECTORS

2-3 Left Side Section
PUSH

i

q
DV CAMCORDER

GY-DV500

u

w
e
r

y
LINE OUT
Y/C OUT MONITOR OUT CH-1
CH-2

SYNC IN

TEST OUT

t

VTR
REMOTE
MIC IN
LENS

1 Cassette cover
Pressing the EJECT switch on top of the section opens this
cover so that a videocassette can be inserted or removed
from the unit. The cover can be locked automatically by
pushing and closing it.
* If the cassette cover is not closed, the GY-DV500 will
remain inoperative.
Memo:
To prevent penetration of foreign objects into the unit,
do not leave the unit with the cassette cover open.

2 [MONITOR OUT] monitor output connector (BNC)
• Composite video signal output connector.
• Setup level signals are output.
An EE image or the playback image is output through the
VCR section.
An EE image is output during other modes than the
playback mode.
* Data for the Camera and VCR setup menus or time code
is not output.
• A setup level signal is not attached to the IEEE1394
signal’s EE image.

3 [Y/C OUT] connector (4P)
Separate YC video signal output connector.

4 [LINE OUT CH-1/CH-2] connector (RCA)
Output connector for audio signals.
• Outputs the input audio signal in the record and stop
modes.
• Outputs the playback audio signal in the playback mode.
• Alarm sound is not output.

5 [TEST OUT] connector (BNC)
Composite video signal output connector.
Outputs the camera image.
Setup level signals are output.

6 [SYNC.IN] connector (BNC)
For inputting the sync signal when the GY-DV500’s camera
image is synchronized with an external component.

18

Memo:
• The camera cannot be synchronized with a VCR
playback signal.
• When the power is switched ON while an external sync
signal is input, the screen moves in a vertical direction
for a few seconds. This is not a malfunction.
• Only for the combined H (horizontal)/V (vertical)
synchronizing signal. Synchronization with the SC (subcarrier) of the input signal is not possible.
Even if SC adjustment is performed, a phase shift will
take place at the time of power on/off. The SC phase
must be adjusted each time the power is turned on.
• If the external sync signal is disrupted during recording,
the “SYNC INH” (SYNC INHIBIT) indicator is displayed
on the counter display and recording stops.
• If the external sync signal is disrupted during playback,
playback of the disturbed video image continues.
Start playback again after synchronization is obtained
and the signal is stabilized.

[VTR REMOTE] connector
A part of the unit's functions can be controlled externally. To
remote control the unit using the control signal of this
connector, the VCR Setup Menu item No. 050 REMOTE
SELECT must be set to "RS232C".
For details, please consult your JVC dealer.
Note:
• When a cable is connected to the VTR REMOTE
connector, the VTR Setup Menu is not displayed in
the viewfinder. Make settings on the VTR Setup Menu
while the cable is not connected.
• When a cable is connected to the VTR REMOTE
connector, the VCR operation mode will not be
displayed correctly on the Status 1 screen in the
viewfinder.

8 Microphone attachment holes
For attaching the microphone holder KA-A50 (optional).
☞ See "Attaching the Microphone (optional)" on page 32.

2. CONTROLS, INDICATORS AND CONNECTORS

2-4 Top Section
q

w

EJECT

PUSH OPEN
LOG

Slide to the side when inser ting or ejecting the
videocassette. Sliding this switch opens the cassette cover.
If the switch is moved while the power is off, the cassette
cover opens but it is not possible to insert or eject the
cassette.

2 Operation cover
Open this cover when operating in the playback mode.
Otherwise, keep this cover closed.

3 [PLAY] button
Press to start playback. In play mode, the unit outputs the
video and audio signals of normal playback and the LED
indicator above the PLAY button lights.
* If the auto tracking is active at the moment the play mode
is entered, the playback video will be interfered with digital
noise.

4 [STOP] button
Press to enter stop mode. The drum keeps rotating in stop
mode. However, when stop mode has continued for about
30 minutes, the unit enters the tape protect mode, in which
the drum stops rotation and the tape tensioner is released.
It takes more time than usual to enter the record or play
mode from the tape protect mode.
* The time until the tape protect mode is initiated can be
set to 3 or 30 minutes with the VCR Setup Menu item No.
307 LONG PAUSE TIME. When used in a cold
environment, the setting will be 3 minutes regardless of
the setting on the VCR Setup Menu.
☞ See page 69.

5 [STILL] button
Press to enter the still picture mode during playback or in
the search or stop mode.
When the still picture mode has continued for about 30
minutes, the unit automatically switches to the stop mode.
(Tape protect mode)
* The time until the tape protect mode is initiated can be
set to 3 or 30 minutes with the VCR Setup Menu item No.
307 LONG PAUSE TIME.

STOP

FF

PLAY

STILL

e r t y u i

w

1 [EJECT] switch

REW

When used in a cold environment, the setting will be 3
minutes regardless of the setting on the VCR Setup Menu.

6 [REW] button
Press to rewind the tape.
• Pressing the button in stop or fast forward mode initiates
the rewind mode. The LED indicator above the REW
button lights in this mode.
• Pressing the button during playback, still or forward search
initiates reverse search at about 10 times the normal play
speed. The LED indicators above the PLAY and REW
buttons light during reverse search.

7 [FF] button
Press to fast forward tape.
• Pressing the button in stop or rewind mode initiates fast
forward mode. The LED indicator above the FF button
lights in this mode.
• Pressing the button during playback, still or reverse search
initiates forward search at about 10 times the normal play
speed. The LED indicators above the PLAY and FF
buttons light during forward search.

8 [LOG] button
• When the REW button is pressed while this button is kept
pressed, the S.S.F. data stored in the unit’s memory are
written to the tape. The LED indicator above the LOG
button lights while S.S.F. data is being written to the tape.
• When the CONTINUE button (6 on page 15) is pressed
while this button is kept pressed in the stop mode, the
tape winds to the S.S.F. data’s last OUT point, after which
the unit enters the record-pause mode. (Scene End Cue
Up)
The FF button’s LED blinks during Scene End Cue Up.
☞ See "Writing S.S.F. Data to Tape" on page 63.
CAUTION:
• Only the EJECT switch and STOP button work during
recording.
• If the cassette cover is open, all operations are
rejected.

19

2. CONTROLS, INDICATORS AND CONNECTORS

2-5 Rear Section
!1
PUSH

0

DV CAMCORDER

GY-DV500

i
o

q
DV

EARPHONE

w

CH-1 AUDIO IN CH-2
LINE

DC INPUT

MIC
+48V
ON

LINE

MIC
+48V
ON

TALLY

LINE OUT
Y/C OUT MONITOR OUT CH-1
CH-2

SYNC IN

TEST OUTPUT

B
VTR
REMOTE

u

MIC

DC OUTPUT

e

LENS
BREAKER

r

t

y
Bottom side

1 [DV] connector

4 [DC INPUT] connector (XLR 4-pin)

Using a DV cable (optional), a digital video component with
DV connector can be connected here.
This connector is used for input and output of the DV signal
or to input the VCR control signal from the digital video
component with DV connector.
• To record the DV signal from this connector, set the VCR
Setup Menu item No. 126 INPUT SELECT to "IEEE1394".
• To remote control the VCR with a VCR control signal from
this connector, set the VCR Setup Menu item No. 050
REMOTE SELECT to "IEEE1394".

Power input connector for 12 V DC. Connect with the AAP250 optional AC power adapter. When a cable is connected
here, the power supply from the battery pack is interrupted
and the source is switched to the power supplied through
this connector.
No.
1

4
2

2 [EAR.] earphone jack
This is a stereo mini-jack for connecting an audio monitoring
earphone. Plug in an earphone or headphone with a 3.5
mm diameter plug. (Monaural mini jack)
The earphone can also be used to monitor alarm tones
depending on situations.
The sound from the monitoring loudspeaker is interrupted
when an earphone is connected here.
Memo:
Only the left-channel sound is heard when a stereo minijack is used.

3 [DC OUTPUT] connector

3

3

1

2

(Surface profile)

20

Signal

1

GND

2

—

3

—

4

DC +12V (power through)

GND

2

—

3

—

4

+12V

3-pin)
Connect the external audio equipment or microphone to
this connector. Set the CH-1 AUDIO IN LINE/MIC select
switch 8 according to the connected equipment.
The audio signal input through this connector is recorded
on the CH-1 audio channel. To record the audio of this
connector, set the CH-1 AUDIO INPUT switch 7 on page
14 to "REAR".
(AUDIO IN connector)
No.
2

No.

1

5 [CH-1 AUDIO IN] CH-1 audio input connector (XLR

Power output connector to a wireless microphone
transmitter, etc. The supply voltage is identical to the voltage
supplied to the unit (DC 12V max. 0.1 A).
4

Signal

1
3

Signal

1

GND

2

HOT

3

COLD

2. CONTROLS, INDICATORS AND CONNECTORS

2-5 Rear Section (Cont'd)
6 [CH-2 AUDIO IN] CH-2 audio input connector (XLR
3-pin)
Connect the external audio equipment or microphone to
this connector. Set the CH-2 AUDIO IN LINE/MIC select
switch 9 according to the connected equipment.
The audio signal input through this connector is recorded
on the CH-2 audio channel. To record the audio of this
connector, set the CH-2 AUDIO INPUT switch 8 on page
14 to "REAR".

7 Back tally lamp
This lamp lights up when the GY-DV500 enters the record
mode. It blinks during the transition to the record mode.
• Use the VCR Setup Menu item No. 082 BACK TALLY
MODE to select whether or not the lamp should light and
the lighting pattern.
☞ See "BACK TALLY MODE" on page 68.

! Battery holder lock release knob
This knob is used to open the battery case cover. Press the
knob to open the cover.

@ [BRAKER]
The braker trips when the power consumption exceeds the
capacity.
If the braker trips, confirm that the power consumption does
not exceed the wattage rating. Then press BRAKER before
turning the power ON again to put the camera in the
operating status.
If the unit still does not work normally, please consult the
person in charge of professional video equipment at your
nearest JVC-authorized service agent.

8 [CH-1 AUDIO IN LINE/MIC] CH-1 AUDIO select
switch
Selects the audio signal input to the 5 CH-1 AUDIO IN
connector.
LINE : Set to this position when connected to audio
equipment, etc. The reference input level is +4 dBs.
MIC : Set to this position when the microphone is
connected. The reference input level is -60 dBs.
MIC +48V ON:
Set to this position when the microphone requiring
+48 V power supply (phantom microphone, etc.) is
connected.
This connector supplies +48 V DC current.

9 [CH-2 AUDIO IN LINE/MIC] CH-2 AUDIO select
switch
Selects the audio signal input to the CH-2 AUDIO IN
connector 6.
LINE : Set to this position when connected to audio
equipment, etc. The reference input level is +4 dBs.
MIC : Set to this position when the microphone is
connected. The reference input level is -60 dBs.
MIC +48V ON:
Set to this position when a microphone requiring +48
V power supply (phantom microphone, etc.) is
connected. This connector supplies +48 V DC
current.
CAUTION:
When connecting a component that does not require +48
V power supply, make sure that the switch is not set to this
position before the connection is made.

0 Battery holder
Mount a Flat Shape type battery pack here.
☞ See "Attaching a Flat Shape Type Battery Pack" on page
36.

21

2. CONTROLS, INDICATORS AND CONNECTORS

2-6 Counter Display Contents
The counter display shows the following 4 types of information.
OPERATE/WARNING
CH 1

RESET

40 30

CH 2
32k
AUD LOCK

MONITOR
SELECT

20

OVER
0 dB
OVER

10

48k

AUTO OFF DEW
SERVO RF L i

PB

NDF

1. Tape counter display

LIGHT
ON
OFF

HOLD

SP

MENU

H

M

REMAIN

REV FWD
H

S

F

E BATT F

M

COUNTER

COUNTER
switch

CTL
TC
UB

Counter display

1. Tape counter display
CTL
TC
UB

“TC”

“CTL”

CTL
TC
UB

M

S

F

H

M

S

F

Time code

“TC”

CTL
TC

VCR Setup UB
Menu No. 516
DISPLAY SELECT
CTL
TC
UB

CTL counter
H

User’s bit

“UB”
Hour Min

Time display

“TC”
H

“CLOCK”

CTL
TC
UB

Sec

M

S

Date display

“UB”
Month Day

Year

The counter display usually functions as a tape counter
(hour, minute, second, frame). It can be switched to a CTL
counter, time code or user's bit display by using the
COUNTER switch. (When the VCR Setup Menu item No.
516 DISPLAY SELECT is set to “TC”.)
• CTL counter: Time between -9 hr. 59 min. 59 sec. 29
frames and 9 hr. 59 min. 59 sec. 29 frames
can be displayed. Running mode is fixed as
non-drop frame.
* CTL counter indication may also corrupt
at playback of segment which time code
signal is not continuously recorded.
• Time code : Time between 0 hour and 23 hr. 59 min. 59
sec. 29 frames can be displayed.
• User's bit : Hexadecimal number from 0 to F is displayed
in 8 digits.
When the VCR Setup Menu item No. 516 DISPLAY SELECT
is set to “CLOCK”, the date and time are displayed. Set the
COUNTER switch to TC or UB.
TC: Time (Hour, Min., Sec.) is displayed.
UB: Date (Month, Day, Year) is displayed.
• Press the MENU button to switch to the VCR Setup Menu
setting display.

2. VCR Setup Menu setting display
2. VCR Setup Menu display

4. Error code display

This display is used when setting the setup menus. After
setting of the setup menus, the tape counter display returns.
For details, see "DISPLAYING AND SETTING VCR SETUP
MENUS" on page 67.

3. Hour meter display
3. Hour meter display

4. Alarm display
H

The hour meter is displayed by selecting the HM group from
the VCR Setup Menu.
The hour meter data refers to the accumulated head drum
running time.

4. Error code/Alarm display

Remaining Tape Time Display
This display shows the remaining tape time (minutes/seconds)
in record and play modes.
• Example: 30 minutes of remaining tape.

REMAIN
H

M

• This indicator blinks when remaining tape time is equivalent
to less than 2 minutes.
* An alarm sounds as a warning when remaining tape time is
equivalent to less than 2 minutes in the record mode

The error code or alarm indicator is displayed automatically
in case an abnormal condition occurs with the unit.
☞ See “TROUBLES WITH ERROR CODE OUTPUTS” on
page 90.
☞ See “ALARM INDICATIONS” on page 86.

Remaining Battery Power Display
The 7-dot segment bar display shows the remaining battery
power. The lighted segment bars decrease as the remaining
battery power decreases.
• To display the remaining battery power accurately, set the
VCR Setup Menu item No. 396 BATTERY TYPE according
to the type of the battery pack in use.

E BATT F

REMAIN
H

M

• The following display appears when no videocassette is
loaded or during the calculation of remaining tape that takes
place immediately after a videocassette is inserted.

REMAIN

22

E BATT

E BATT
H

All segment bars light when a fully charged
battery pack is attached.

M

The last 2 segment bars and "BATT" start
to blink when the batter y is nearly
exhausted. Replace with a fully charged
battery pack.
When the battery capacity has run out, "E"
and "BATT" blink and the unit stops
operation automatically.

2. CONTROLS, INDICATORS AND CONNECTORS

2-7 Lens (optional)
[S14 x 7.3B12]

7 IRIS mode switch
e

w

A: Activates the auto iris feature.
M: Allows manual iris control.

q

8 Momentary auto iris button
When the IRIS MODE switch 7 is at "M", pushing this button
activates the Auto Iris Function while it is held down only.

9 [S] IRIS speed adjusting control
For adjusting the iris operation speed.

RET

Memo:
If the speed becomes too fast, hunting may occur.
• To avoid the phenomena described above, perform
adjustment again.

M
A

W

T

0 FILTER thread
Protect the lens with a clear filter or UV filter by screwing
the filter onto the thread inside the lens hood from the front.
Other filters can be used for various effects.

r

t

y

u i o

!0

CAUTION:
The filter thread section rotates, so pay attention when
mounting a polarizing filter.

!4

! ZOOM servo connector
Connect an optional zoom servo unit here.

MACRO

@ ZOOM mode knob
S: Servo zoom mode. Allows operation by the zoom servo
control lever 6.
M: Manual zoom mode. Allows zoom control by the zoom
lever/ring 2.

# BACK FOCUS ring/fixing screw

1 FOCUS ring

!1

!2

!3

Manual focus ring.

2 ZOOM lever/ring
This is the manual zoom ring equipped with a zoom lever.
To adjust the zoom manually, turn the zoom mode knob @
to position "M".

3 IRIS ring
Manual iris ring. To activate the auto iris feature, set the Iris
Mode switch 7 to A.

4 [VTR] Trigger button
To start/stop shooting.

5 [RET] return video button
The return video signal from the VCR section can be
monitored in the viewfinder only while this button is pushed.
* The playback picture can be viewed in the viewfinder
during this operation.

6 ZOOM servo control lever

For back focus adjustment only. Secure with the screw knob
after adjustment.
☞ See “Back Focus Adjustment” on page 44.

$ Macro focusing ring (for close-up shooting)
By rotating this ring in the direction of the arrow, close-up
shooting of very small objects becomes possible.
Normal focus adjustment and zooming are not available in
the macro mode.
To shoot images in the macro mode, set the focus ring 1 to
the infinite position and the zoom ring 2 to the maximum
wide-angle position. To adjust the focus of the macro image,
rotate this ring in the direction of the arrow until the object
is focused.
CAUTION:
• The back-focus knob is located close to the macro ring,
be careful not to mistake the back-focus knob for the
macro ring.
• After the required operation, be sure to return the macro
focusing ring to the normal position.
☞ See “Attaching the Zoom Lens (optional)” on page 31.
☞ See “Back Focus Adjustment” on page 44.

To operate the servo zoom feature with this lever, set the
ZOOM knob @ to S.
• Pressing the W section of this lever increases the angle
of the lens for a wider shooting angle.
• Pressing the T section of this lever narrows the lens angle
perspective for telephoto shots.
• Pushing harder changes the speed of the zoom.

23

2. CONTROLS, INDICATORS AND CONNECTORS

2-8 1.5-Inch Viewfinder (optional)
1 Stopper screw

[VF-P115B]

This screw prevents the viewfinder from coming off the
camera.
6

2 Mounting guide
To attach on the camera.

3 Connector
Connect to the camera.

4 [CONT] contrast adjustment
To adjust the contours of the viewfinder image.
1

5 [BRIGHT] brightness adjustment
To adjust the brightness of the viewfinder.

6 [TALLY] switch
4

2

5

3

Set this switch to OFF to prevent the tally light 7 from turning
on and informing people that they are being recorded.
However, the REC indicator lamp in the eyepiece will not
turn off.

7 Tally light
Lights when recording is in progress. To prevent this light
from coming on, set the tally switch 6 to "OFF".

8 Eyepiece
Ensures that ambient light does not reach the viewfinder
screen or falls into the eye of the cameraman.
The eyepiece can be opened to allow direct observation of
the viewfinder screen.

9 Eyepiece focusing ring
Loosen this ring to move the eyepiece back or forth to adjust
the diopter.

7

8
9

24

2. CONTROLS, INDICATORS AND CONNECTORS

2-9 Indications in Viewfinder
n WARNING LED INDICATORS INSIDE THE VIEWFINDER

BATT

REC

ALARM

BATT
Lamp

The viewfinder has two LED indicators below the screen. These
LEDs light or blink to indicate the present status of the camera
or the VCR.
● [BATT] battery lamp
This lights red when the battery voltage becomes too low for
operating the camera.
● REC/ALARM lamp
This lights or blinks green under the following circumstances.
Steady green : During recording.
Blinks green : • While the GY-DV500 switches from recordpause to recording.
• Immediately before the tape is running out
or when it has run out.
• When an error occurs in the GY-DV500.

REC/ALARM
Lamp

n VIEWFINDER SCREEN DISPLAY
The following indications are displayed on the viewfinder screen. (However, this information is not displayed while the VCR section
is playing back a tape.)
n Status screens (screens for use in checking the current camera settings)
n Alarm message display
n Safety zone display
n Setting screen (screen for use in the camera and VCR setup)
n Auto white balance display
n Shutter speed display

n Status Screens
Press the STATUS button during normal screen display to show one of the status
screens in the viewfinder. One of the three status screens will be displayed every
time the button is pressed.
OPERATE/WARNING

STATUS
button

LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK

GAIN

OFF ON
AUTO KNEE

HML

BARS CAM

SAVE STBY

VTR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

PRST A B

AUTO IRIS

.BAL
OUTPUT WHT

POWER

NG
ON

OFF

ACCU - FOCUS

ACCU - FOCUS

G

G

F

F

I
SD
B

I
SD
B
F5 . 6
STBY

Status 0

CH1
CH2

- - - -+- - - - -+- < 60

Status 1

SCENE F I L E
WH I TE BA L
F I L TER
SHUT TER
GA I N
I R I S L EVE L
I R I S DETECT
FUL L AUTO
REC T I ME

A
A
3 . 2K
1 / 1000
6 dB
NORMA L
NORMA L
OF F
<60

M 09 9
1 2 . 4V

Status 2

25

2. CONTROLS, INDICATORS AND CONNECTORS

2-9 Indications in Viewfinder (Cont'd)
1
2
3
4
5
6

ACCU - FOCUS
G
F
I
SD
B

1
2
3
4
5
6
C

ACCU - FOCUS
G
F
I
SD
B

7
CH1
CH2

F5 . 6
STBY

7

9

Status 0

- - - -+- - - - -+- < 60

B

M 09 9
1 2 . 4V

0 8

SCENE F I L E
WH I TE BA L
F I L TER
SHUT TER
GA I N
I R I S L EVE L
I R I S DETECT
FUL L AUTO
REC T I ME

A
A
3 . 2K
1 / 1000
6 dB
NORMA L
NORMA L
OF F
<60

A

Status 1

Status 2

● Status 0
Display Position

1

Display
ACCU-FOCUS

SKIN AREA

3
4
5
6
7

Blinks during the ACCU-FOCUS operation.
Blinks while the skin tone detail color area is displayed.
Displayed when the SHUTTER or V-SCAN is ON.

S

2

Function

FAS

Displayed when the Full Auto Shooting is ON.

ALC

Displayed when the ALC alone is ON.

G

Displayed in other modes than 0 dB, LOLUX and ALC.

L

Displayed during LOLUX operation.

F

Displayed when FAW alone is ON.

I

Displayed when IRIS BACK LIGHT or IRIS SPOT LIGHT is selected.

SD

Displayed while the Skin Detail function is in operation.
Displayed when BLACK STRETCH or BLACK COMPRESSION is selected.

B
Event display

See the table below.

7 Event display
Event is displayed in the viewfinder for only about 2 seconds when any of the following switches is operated.
Switch

26

Event Display Contents

ZEBRA

ZEBRA

ON, OFF

BLACK

BLACK

STRETCH, NORMAL, COMPRESS

GAIN

GAIN

–3 dB, 0 dB, 6 dB, 9 dB, 12 dB, 18 dB, ALC

WHT. BAL

WHITE BAL

A, B, PRESET, FAW

FULL AUTO

FULL AUTO

ON, OFF

AUTO IRIS

IRIS

BACK.L, NORMAL, SPOT.L

LOLUX

LOLUX

ON, OFF

FILTER knob

FILTER

3.2K, 5.6K, 5.6K+ND

VTR

VTR

STBY, SAVE

AUTO KNEE

AUTO KNEE

ON, OFF

2. CONTROLS, INDICATORS AND CONNECTORS

2-9 Indications in Viewfinder (Cont'd)
● Status 1
In addition to the information on the Status 0 screen, this screen displays audio indicators and information on remaining tape,
voltage and lens F-number.
Display position

8
9

0

Function

Display
(Example)
CH1- - - - + - CH2- - - - + - STBY
SAVE
STOP
REC
FF
REW
EJECT
(Example)
< 60
(Example)
12: 34: 56: 20

Shows the input level of the audio input channel.
Display ON/OFF can be selected using the VF DISPLAY menu screen.
☞ See "AUDIO DISPLAY" on page 72.
VCR in standby mode
Note:
VCR in save mode
When the RS-232C cable
VCR in stop mode
is connected, the VCR
VCR in record mode
operation mode may not
VCR in fast-forward mode
be displayed correctly.
VCR in rewind mode
VCR in reverse search mode
Remaining tape indication (displayed in 1-minute steps)
When the tape is used for a long time, the remaining tape may not be
indicated accurately. At the beginning of the tape, in particular, the indication
may show smaller value than the actual one.
Time code display
Time code display is available when the "REC TIME" item on the VF DISPLAY
menu screen is set to TIME CODE.
☞ See "REC TIME" on page 72.
Voltage indication (displayed in 0.1 V steps)

A

(Example)
12.4V

B

OPEN, F2, F2.8, F4,
F5.6, F8, F11, F16,
CLOSE

Shows the F-number of the connected lens.
It is not displayed when the lens is removed. For some lenses, no display
appears.
Display ON/OFF can be selected on the VF DISPLAY menu screen.
☞ See "F NO.DISPLAY" on page 72.

C

(Example)
M:99

In the Super Scene Finder (S.S.F.) mode, the number of memorized scenes
is shown.
M : In MARK mode
C : In CUE mode
Number: Number of memorized scenes

● Status 2
This screen displays the camera setup statuses.
Event display is not available while this screen is displayed.
Indication

Indication Contents

SCENE FILE

A, B, OFF

WHITE BAL

A, B, PRESET, FAW

FILTER

3.2K, 5.6K, 5.6K+ND

SHUTTER

OFF, 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/60.1 to 1/2084.6 (in VARIABLE mode),
EEI (in ALC mode)

GAIN

-3dB, 0dB, 6dB, 9dB, 12dB, 18dB, LOLUX, ALC

IRIS LEVEL

NORMAL, BACK L, SPOT L

FULL AUTO

ON, OFF

REC TIME

Remaining tape time or time code.

27

2. CONTROLS, INDICATORS AND CONNECTORS

2-9 Indications in Viewfinder (Cont'd)
n Alarm Message Display
ACCU - FOCUS
G

Alarm message display
F
I

The following alarm messages are displayed on the status 0 and status 1
screens.

B
F5 . 6
STBY

CH1
CH2

- - - -+- - - - -+- < 60

1 2 . 4V

Indication

Contents

LOW BATTERY
CLOSE CASSETTE COVER

The battery capacity is nearly exhausted.
The cassette cover is not closed.

VTR WARNING [HEAD]
VTR WARNING [SERVO]
VTR WARNING [DEW]
VTR WARNING [HARD]
VTR WARNING [STOP]
VTR WARNING [REW]

Head clogging
Servo error
Condensation
Hardware error
Operation stopped
Rewinding abnormality

TAPE NEAR END
TAPE END
REC INHIBIT

Remaining tape time is less than about 2 minutes in the record mode
Tape end reached
An unrecordable videocassette (the switch on the back of the cassette is set to SAVE) is
inserted.
VTR trigger is pressed with no tape loaded.

NO TAPE

28

2. CONTROLS, INDICATORS AND CONNECTORS

2-9 Indications in Viewfinder (Cont'd)
n Safety Zone
Three types of safety zone items can be displayed in the viewfinder. Select the required one with the SAFETY ZONE item on the
VF DISPLAY menu screen.

OFF

ZONE 1

ZONE 2

ZONE 3

n Setting the Screen Display
- - - CAMERA MENU - - SCENE F I L E
VF D I SP L AY MENU
OPERAT I ON MENU
PROCESS MENU
F I L E MANAGE
SETUP MENU
EX I T

:A

Screen used for making various settings of the camera and VCR.
☞ See "Camera Menu" on page 70.
☞ See "VCR Setup Menu" on page 66.

n Auto White Balance Display
This screen appears during the auto white balance adjustment operation to display various
data.
☞ See "White Balance Adjustment" on page 45.
A U T O WH I T E A
OP E R A T I ON

n Shutter Speed Display
When the SHUTTER dial is pressed, a shutter speed is displayed (for approx. 5 sec.).
In addition, whenever the shutter speed is altered by using the SHUTTER dial, the shutter
speed is displayed. While this display is shown, other displays disappear.
☞ See "SHUTTER Dial" on page 12.
S HU T T E R 1 / 1 0 0 0

29

3. BASIC SYSTEM CONNECTIONS AND ADJUSTMENTS
3-1 Basic System
For information on connection with the individual attachments, refer to the page explaining the respective connection methods.

VIEWFINDER
VF-P400

BATTERY
NP-1B TYPE

EARPHONE

MICROPHONE
MV-P615

BATTERY CHARGER

3P

BATTERY
NP-1B TYPE

SHOULDER BELT
MIC HOLDER
KA-A50

VF HOLDER

1.5" VIEW FINDER
VF-P115B
VF-P116

BATTERY HOLDER
BH-P27
DVC CAMCORDER

MICROPHONE

BATTERY
NB-G1

NB-G1 (4PACK) BATTERY CHARGER
(AC POWER ADAPTER)
AA-G10(B)

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK

HML

SAVE STBY

GAIN

OFF
BARS CAM
AUTO KNEE
ON

MACRO

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

VTR

PRST A B

AUTO IRIS

4P

OUTPUT WHT.BAL

POWER

NG
ON

4P

OFF

VC-710 (5m)

VIDEO LIGHT
(ANTON BAUER. PROTEC)

ZOOM LENS
S14 x 7.3B12(FUJINON)
S16 x 6.7B12(FUJINON)
S19 x 6.5B12(FUJINON)
YH14 x 7.3K12(CANON)
YH18 x 6.7K12(CANON)

FOCUS MANUAL UNIT
HZ-FM13 (FUJINON)
HZ-FM15 (CANON)

TRIPOD BASE
KA-510

GY-DV500
STANDARD PACKAGE
ANTON BAUER
BATTERY HOLDER
(QRQ27)

ANTON BAUER BATTERY
(PRO PAC, MAGNUM,
TRIMPAC, HYTRON)

TRIPOD
TP-P300

ZOOM SERVO UNIT
HZ-ZS13B

ANTON BAUER
BATTERY CHARGER

IEEE1394 CABLE
CARRYING CASE

DOLLY
TP-P205

* HZ-FM13 cannot be used with S14X7.3B12/U.
Please use the Focus Manual Unit (FMM-8, CHF-3, CFC-12-990) manufactured by Fujinon.

30

AC

AC POWER ADAPTER
(NB-G1 BATTERY CHARGER)
AA-P250

RS232C CABLE
VC-P893 (For PC/AT)
Y/C CABLE
VCG30, VCG50
BNC CABLE

3. BASIC SYSTEM CONNECTIONS AND ADJUSTMENTS

3-2 Attaching the Zoom Lens (optional)

1.

1. Loosen the mount ring.
2. Connect the cable connector.
3. Attach the lens with its pin aligned with the hole in the mount.
4. Tighten the mount ring.

4.

CAUTION:

3

Be sure to tighten the mount ring completely. Incomplete
tightening may result in the lens dropping off or disturbed
back focus.

2.
Pin

Hole

Mount ring

When unplugging the cable connector, first remove the lens
itself. Then grasp this portion and pull straight out.

3-3 Attaching the Viewfinder
5.
Sliding
securing ring

1.
4.

Mounting guide

base and attach the viewfinder.

Stopper
screw

4. Tighten the stopper screw.
5. Tighten the sliding securing ring.

3.
Viewfinder
mount
base

2.

1. Loosen the stopper screw on the viewfinder.
2. Connect the connector.
3. Align the mounting guide with the camera’s viewfinder mount

* To detach the viewfinder, reverse the mounting procedure.
Connector

31

3. BASIC SYSTEM CONNECTIONS AND ADJUSTMENTS

3-4 Attaching the Microphone (provided)
Provided Microphone

Connecting the provided microphone to the viewfinder.
The provided microphone is a phantom microphone.

1.3.

1. Loosen the stopper screw on the viewfinder.
2. Attach the microphone to the attachment guide on the
4.
2.

viewfinder as illustrated.

3. Confirm that there is no gap between the microphone and
the viewfinder, and then tighten the stopper screw.

4. Tighten the microphone screw. The microphone should be
firmly attached.

5. Connect the cable from the microphone to the MIC IN
connector on the front section of the camera.

6. Secure the microphone cable using the cable clamp
5.

provided on the front side of the microphone holder.
CAUTION:
When this microphone is attached, the range that the
viewfinder can be moved to the left will be reduced. Please
purchase a separately sold microphone if you prefer to
observe through the viewfinder using your left eye.

3-5 Attaching the Microphone (optional)
1.

With the optional KA-A50 microphone holder, the optional
microphones MV-P615 (Phantom microphone) can be used.

2. 4.

n Attaching the Microphone with KA-A50

1. Secure the microphone holder with 2 screws.
2. Turn the small knob located on the outer side of the
microphone holder anticlockwise to loosen it, and loosen
the large knob located on the inner side in the same way.
Rotate the large knob fully anticlockwise to open the holder.

3. Attach the microphone to the microphone holder so that
the microphone does not interfere with the cassette cover.

4. Set the microphone holder so that the height is level, and
KA-A50

Microphone holder

tighten the inside and outside knobs to secure the
microphone.

5. Connect

3.

the microphone cable to the MIC IN input
connector.
• When the microphone is connected to CH-1 AUDIO or
CH-2 AUDIO connector on the rear panel, set the CH-1
or CH-2 Audio select switch according to the microphone
used.

6. Secure the microphone cable using the cable clamp
provided on the front side of the microphone holder.

7. Make sure to perform the correct settings for use of a
phantom microphone.
☞ See “CAM, MIC, 48V” on page 77.

MV-P615
Microphone cable
MIC IN connector

32

Note:
• When the light mounted on the camera is used at the
same time, if the microphone in use has a long sound
collecting section (ultra-directional type, etc.), the
microphone's shadow may influence the image.

3. BASIC SYSTEM CONNECTIONS AND ADJUSTMENTS

3-6 Attaching the Tripod Base (provided)
Use the provided tripod base to place the camera on a tripod.

1. Attach the tripod base on the tripod by using the hole that
balances the unit most optimally.

2. While pushing the safety lever, pull the lock lever toward

1. Tripod mounting holes

the front until the front mount clip clicks into place.

3. Place the unit on the tripod base by aligning the rear base

Front mount clip

mount of the unit with the pin on the tripod base.

4. Push the unit from the upward direction and slide it toward

2. Safety lever
2.
Lock lever

4.
Front
base
mount

3.

the front so that the front base mount of the unit is locked
by the front mount clip of the tripod base as it clicks into
place.
CAUTION:
• The front base mount may be locked while the pin of the
tripod base is not inserted into the hole on the rear base
mount of the unit. Therefore, after mounting, make sure
that these parts are engaged properly.
• When moving the unit mounted on a tripod, any impact
or vibration should be avoided as this may cause the unit
to become detached and to drop from the tripod.
Be sure to remove the unit from the tripod before
transporting it.

Rear base
mount

Front mount clip

Pin

4.

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

PRST A B

HML

GAIN

BARS CAM

STRETCH
NORMAL
COMPRESS

SAVE STBY

VTR

AUDIO CH-2
LEVEL

LOLUX

OFF ON
AUTO KNEE

AUTO IRIS

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

33

3. BASIC SYSTEM CONNECTIONS AND ADJUSTMENTS

3-7 Inserting and Replacing Backup Lithium Batteries
The GY-DV500 uses a lithium battery for backup of the time code data and time date data. Install the provided lithium battery before
actually using the unit.

● Lithium battery: CR2032
"Li" indicator
CAUTION:
If the unit is not used for a lengthy period of time (one
month or more), remove the lithium battery. If the voltage
of the lithium battery becomes low, the set may malfunction.
OPERATE/WARNING
RESET
MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

ALARM

CH 1
40 30

CH 2
32k
AUD LOCK

20

PB

MENU

H

AUTO OFF DEW
SERVO RF L i
NDF

M

REMAIN

REV FWD
H

SHUTTER STATUS

OVER
0 dB
OVER

10

48k

LIGHT
ON
OFF

HOLD

SP

M

S

E BATT F

F

COUNTER
CTL
TC
UB

CH-1

CH-2

AUDIO
LEVEL

CH-1

PRESET
REGEN

AUDIO SELECT
AUDIO INPUT

MENU

CH-1

CH-1 AUDIO CH-2

LEVEL
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

B

LITHIUM BATT.
PRST A

HML

BARS CAM

SAVE STBY

FREE
REC

CONTINUE

CH-2

MENU

FRONT
REAR

LOLUX
STRETCH
NORMAL
COMPRESS

OFF ON
AUTO KNEE

AUTO IRIS

VTR

TC GENERATOR

CH-2
AUTO
MANUAL

MONITOR

GROUP

ITEM

HOLD

SHIFT

SELECT

DATA SET

ADVANCE PRESET

.BAL
OUTPUT WHT

GAIN

POWER

NG
ON

OFF

Lithium battery case
Power switch
When the lithium battery is not in place or the battery is exhausted and requires a replacement, the "Li" indicator in the LCD display
will light up.
Replace lithium batteries with the POWER switch set to ON. Doing it with the POWER switch set to OFF will cause the loss of
backup data.

n How to Install the Lithium Battery

n How to Remove Lithium Batteries

Lithium battery cover
CR

CR

20

20

32

LITHIUM BATT.

32

CR

20

32

1. Push the lithium battery cover in the direction of the arrow
as illustrated and remove the cover.

2. Slide the battery into place with its

marked surface facing

upward.

3. Return the lithium battery cover to its original position in the
unit.

34

n The lithium battery is easily removed
if you press at the edge of the
lithium batter y at the place
indicated in the illustration on the
left and then pull the battery out.

4. POWER SUPPLY
The GY-DV500 is operable with AC power supply or battery pack.

4-1 AC Operation
Use the JVC AA-P250 AC power adapter (max. rated output 12.5 V DC, 3.5 A) as the AC power supply.

Do not use any power source with large fluctuations in the
power source voltage, or power sources generating noise,
such as ripples.

1. After making sure that the power switches of the GY-DV500
and of the AA-P250 are set to OFF, connect the DC cable
from the AA-P250 to the DC INPUT connector of the GYDV500 as shown in the illustration.
DC cable

EARPHONE

DV

CH-1 AUDIO IN CH-2
LINE

DC INPUT

MIC
+48V
ON

LINE

MIC
+48V
ON

TALLY

DC OUTPUT

2. When the AA-P250 is used, set the CHARGE/CAMERA
switch to CAMERA.

AC power adapter

3. Press the POWER switch of the GY-DV500 to ON. Power is
Note:
Do not remove or connect the DC cable while recording is
being performed.

supplied to the VCR section and the camera.
* For details, read the instruction manual of the AA-P250.

4-2 Battery Pack Operation
The GY-DV500 can be operated with the following battery packs.
n Flat shape type battery pack
n Anton-Bauer battery pack
• Propack 13/14 Series
• Trimpack 13/14 Series
• Magnum 13/14 Series
• Compack 13/14 Series







* An Anton-Bauer battery pack cannot be connected
directly to the GY-DV500. It is necessary to mount the
optional battery holder.
Battery holder: Anton-Bauer QRQ27
For details on how to mount the battery holder, see
page 37.

● When the DC cable is connected to the DC INPUT connector, the power supply from the battery pack is interrupted and the
power starts to be supplied through the DC INPUT connector.
● Do not connect or disconnect the DC cable while operating with a battery pack.
The following symptoms may occur if the DC cable is connected or disconnected while operating with a battery pack.
• The power is cut off for a moment when the DC cable is disconnected.
• Noise to the video and audio signals occurs. Audio signal are muted.
● When operation is continued with DC input after the battery pack capacity has been used up, set the POWER switch to OFF
after the DC power is applied. Then switch ON again.
● If the GY-DV500 is left with the battery pack attached, a small amount of power is consumed even if the POWER switch on
the GY-DV500 is set to OFF. Remove the battery pack when the GY-DV500 is not going to be used.

35

4. POWER SUPPLY

4-2 Battery Pack Operation (Cont'd)
Attaching a Flat Shape Type Battery Pack

1. Open the battery case cover while pushing the lock release
lever.

2. Insert the battery pack into the battery case with its electrodes
facing the unit.

3. Close the battery case cover.
Lock release
lever

36

Be sure to set the POWER switch to OFF before replacing
the battery pack.

4. POWER SUPPLY

4-2 Battery Pack Operation (Cont'd)
Using an Anton-Bauer Battery Pack
To use an Anton-Bauer battery pack (Propack 13/14, Trimpack 13/14, Magnum 13/14, Compack 13/14 Series), it is necessary to
detach the battery case from the GY-DV500 and replace it with the Anton-Bauer battery holder. Use the following battery holder.
• Battery holder: Anton-Bauer QRQ27

Detaching the Battery Case From the GY-DV500 and Attaching The AntonBauer Battery
Attaching the Anton-Bauer Battery Holder
Anton-Bauer Battery Holder

1.

Black screw A

Connector
Compartment

1. Remove the two black screws A on the battery case.
2. Remove the lower half of the battery case cover in the
downward direction.

3. Connector
Anton-Bauer
Battery holder

3. Mount screw B

4. Connect the connectors protruding from the GY-DV500 with
the connectors on the battery holder.
* Following connection of the connectors, insert them into
the connector compartment and secure with the clamp.

5. Secure the battery holder to the GY-DV500 with the four
mount screws provided with the battery holder.

3. Mount screw B
3. To remove the battery case, remove the four screws B fixing

* Take care not to pinch the wires. This could result in
damage.

the battery case and the connector connecting the battery
case to this unit.

Attaching and Detaching an Anton-Bauer Battery Pack
Guide pins

Release lever

Cassette cover
side panel
Guide Battery pack
holes (Trimpack)
(x3)

Release
lever

Attaching the Battery Pack

1. Align the 3 guide pins of the battery pack with
the guide holes on the battery holder, and push
straight to insert the battery pack.
The battery cannot be attached properly if the
guide pins are not inserted straight.

LIGHT
ON
OFF

COUNTER
CTL
TC
UB

2. Slide the battery pack toward the side panel
Battery

Side panel
with display

where the cassette cover is located until it clicks.
Now the battery pack has been attached.

Detaching the Battery Pack
n While pushing and holding the release lever, slide
the battery pack toward the side panel where the
LCD display is located, then pull the battery pack
outward to remove.

37

4. POWER SUPPLY

4-2 Battery Pack Operation (Cont'd)
REMAINING BATTERY POWER DISPLAY
WARNING
indicator

To display the remaining battery power accurately, set the
VCR Setup Menu item No. 396 BATTERY TYPE according
to the type of the battery pack in use.
☞ See page 69.

Remaining battery
power indication

E BATT F
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

HML

SAVE STBY

GAIN

OFF
BARS CAM
AUTO KNEE
ON

VTR

AUDIO CH-2
LEVEL

E BATT

LOLUX
STRETCH
NORMAL
COMPRESS

PRST A B

AUTO IRIS

L
OUTPUT WHT.BA

TALLY lamp

POWER

NG
ON

OFF

Viewfinder

LOW BATTERY

REC

BATT lamp

BATT

The status of the remaining battery power can be checked by
the remaining battery power indication.
☞ See page 22.
n When the remaining battery power is nearly exhausted, the
following warning messages will appear. In this case, replace
with a fully charged battery as soon as possible.
● Remaining battery power indication:
Segment bar and "BATT" indicator start to blink
● WARNING indicator and TALLY lamp blink
● Viewfinder:
• BATT lamp and TALLY lamp blink
• "LOW BATTERY" character indication (Status 0 or Status
1 mode)
● Alarm sound beeps

ALARM

After the remaining battery power warnings appear, the
GY-DV500 automatically stops operation if the battery
power operation is continued.

Operating Time with Battery Pack
When the VF-P115B is used as the viewfinder and a fully
charged battery pack is attached, the approximate continuous
operating time is as follows:
Battery Pack

Continuous Operating Time (at 25 ˚C)

NP-1B

60 minutes

Magnum 14

130 minutes

NP-L40

80 minutes

● Battery operating time may differ depending on the number
of times the battery has been charged, charging conditions
and the operating environment, etc. Use the values in the
table on the left for approximate reference times.
● Operating time is reduced in areas with a cold environment.
● Operating time is reduced when the power zoom lens is used
frequently.

PRECAUTIONS FOR THE BATTERY PACK
● When the battery pack is not in use, it must be stored in a
cool, dry place.
Do not leave the battery pack in a place where it might be
subject to a high temperature (under direct sunlight in a car,
etc.), this could cause leakage of the fluid or shorten service
life.
● When the terminal section of the battery pack gets dirty, the
operating time will be shortened.
● If the operating time becomes greatly reduced even
immediately after recharging, the service life of the battery
pack is nearly finished. Purchase a new battery pack.

38

Recharging
● Recharge the battery pack after completely discharging it.
Repeated recharging with residual charge remaining could
result in reduced battery capacity.
● If the battery capacity is reduced by repeating incomplete
recharging, or recharging without discharging, once discharge
the battery pack completely, then recharge it to restore the
battery capacity.
● If the battery pack is recharged with its internal temperature
raised immediately after use, recharging may not be
performed completely.

5. PREPARATIONS
5-1 Turning the Power ON

AUTO IRIS

FULL AUTO BLACK
BACK L
NORMAL
SPOT L

LOLUX
STRETCH
NORMAL
COMPRESS

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

COUNTER

SAVE STB

MONITOR

Y

MENU
CH-1
FULL AUTO BLACK

OFF
BARS CAM
AUTO KNEE
ON

HML

SAVE STBY

GAIN

VTR

AUDIO CH-2
LEVEL

VTR

GAIN

T.BAL
OUTPUT WH

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

PRST A B

AUTO IRIS

HML

SHUTTER STATUS

OFF
E BARS CAM
AUTO KNE
ON

CTL
TC
UB

ALARM

PRST A B

FILTER
1 3200k
2 5600k
3 5600k+ND

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

POWER

NG
ON

OFF

2. VTR switch 1. POWER switch
1. Turn the POWER switch to ON.

n The power is then supplied to the unit.
• Video image is output to the viewfinder.
• The display of the VCR section is turned on.

2. Select the GY-DV500 operation mode with the VTR switch.
• The GY-DV500 operation mode may differ when the power is turned ON and when the cassette is loaded depending on the
setting of the VTR switch as follows:
VTR switch setting

GY-DV500 operation mode

SAVE

GY-DV500 enters the SAVE mode (tape protect mode) and stops the drum motor. "SAVE" is
displayed in the VCR operation indicating section of the Status 1 mode screen in the viewfinder.
In this mode, the tape is effectively protected.
In this condition, press the VTR trigger button to start recording. However, it takes longer for
the operation to take place from this condition than from the STBY mode.

STBY

When a recordable videocassette is loaded, the GY-DV500 enters the record-pause mode
automatically. (The drum motor is still rotating.)
"STBY" is displayed on the Status 1 screen in the viewfinder.
In this condition, pressing the VTR trigger button starts recording immediately.

CAUTION:
Wait at least 5 seconds before turning the power ON again once it has been turned OFF.
When the power is turned OFF, the unit automatically enters the tape protect mode. It takes approximately 5 seconds to enter
the tape protect mode. Do not turn the power ON again within this interval.

39

5. PREPARATIONS

5-2 Cassette Loading and Unloading
Cassette rear switch
EJECT

Videocassette
EJECT switch

LOG

OFF
E BARS CAM
AUTO KNE
ON

HML

SAVE STB

Y

GAIN

FF

PLAY

STILL

T.BAL
OUTPUT WH

POWER

NG
ON

VTR switch

STOP

PRST A B

VTR

REW

OFF

Cassette cover

POWER switch

• A cassette cannot be loaded or unloaded while the GY-DV500 is in POWER OFF mode.
• Use a videocassette tape marked MiniDV.
• The videocassette should be held vertical and inserted straight into the slot.

Loading the Cassette

1. Set the POWER switch to ON.
2. Slide the EJECT switch to the side to open the cassette

CAUTION:
The GY-DV500 cannot be operated while the cassette cover
is open. Make sure to close the cover before operating the
unit.

cover.

3. Insert a videocassette into the cassette slot after removing
the tape slack.
Ensure that the videocassette is fully inserted.
The cassette indicator on the display blinks
during tape loading and lights steadily after
the loading has been completed.

4. Slowly close the cassette cover by pushing it in all the way.
When the cassette cover is closed, the OPERATE LED lights
up green and the unit is in the condition where it can be
operated. In the SAVE mode, the OPERATE LED lights
orange.
• The condition at the completion of loading varies depending
on the position of the VTR switch and the switch on the back
of the videocassette as shown below.
VTR switch
STBY

SAVE

Switch on Back of Videocassette
REC

SAVE

Enters recordpause mode after
back-spacing.

The unit enters
stop mode.
“REC INH” is
In the record-pause displayed for a few
mode and the drum seconds on the
rotation is stopped. counter display.

* Recording can be started by pressing the VTR trigger button
from the record-pause condition. For details on how to record,
see page 50.
After the cassette cover is closed, it takes about 8 seconds
before the unit can start recording or before it enters the
stop mode.

40

Unloading the Cassette

1. Set the POWER switch to ON.
2. Slide the EJECT switch all the way to the side to start tape
ejection.
The cassette indicator on the display blinks
during tape ejection and turns off after the
ejection has been completed.
• It takes a few seconds before the cassette is ejected after
the EJECT switch is moved.

3. Take out the videocassette.
4. Close the cassette cover.
CAUTION:
Do not leave the unit for a long period with the cassette
cover open as dirt or other foreign objects may enter the
VCR section and cause malfunction.

5. PREPARATIONS

5-3 Setting the Date and Time
The date and time of the built-in clock should be set. During shooting, the date and time data are recorded in the sub-time code area
on the tape.
During playback, the data are shown on the counter display. Powered by the backup lithium battery, the set date and time data
continue to count even when the power is switched off.
n Check that the lithium battery has been inserted.

CH-1

CH-2

AUDIO
LEVEL

CH-1

OPERATE/WARNING
CH 1

RESET

40 30

CH 2
32k
AUD LOCK

MONITOR
SELECT

20

OVER
0 dB
OVER

10

48k

PB

PRESET
REGEN

H

SERVO RF L i
NDF

M

REMAIN

ON
OFF

HOLD

REV FWD
H

S

F

E BATT F

M

AUDIO SELECT
AUDIO INPUT

LIGHT

SP

MENU

M

AUTO OFF DEW

COUNTER
CTL
TC
UB

2.
COUNTER
switch

ONITOR

TC GENERATOR

CH-2
AUTO
MANUAL

CH-1

FREE
REC

CONTINUE

CH-2

MENU

FRONT
REAR

LITHIUM BATT.

GROUP

ITEM

HOLD

SHIFT

SELECT

DATA SET

ADVANCE PRESET

CH-1 AUDIO CH-2

LEVEL

3. HOLD
button

4. SHIFT button
Lithium battery compartment

5. PRESET button
4. ADVANCE button

1. Turn ON the power and set the counter display to the date/
Time display (COUNTER switch: TC)
Hour Min.

Sec.

HOLD

H

M

S

HOLD

H

M

time mode.
• Set the VCR Setup Menu item No. 516 DISPLAY SELECT
to “CLOCK”.
☞ See “Displaying and Setting VCR Setup Menus” on
page 67.
☞ See “VCR Setup Menu Contents” on page 69.

2. Set the COUNTER switch to TC or UB.

n To set the time: Set the switch to TC.
The time (Hour, Min., Sec.) is indicated on the counter
display. (24-hour clock system)
n To set the date: Set the switch to UB.
The date (Month, Day, Year) is indicated on the counter
display.

S

3. Press the HOLD button to enter the setting mode.
H

M

The “HOLD” indicator lights up on the display to indicate
that the unit is in the setting mode.
The leftmost digit on the counter blinks.

S

4. Set the date and time.
Date display (COUNTER switch: UB)
Month Day

Year

HOLD

HOLD

• Each time the ADVANCE button is pressed, the value of
the blinking digit increases.
• Each time the SHIFT button is pressed, the digit to the
right of the currently blinking one starts blinking. When
pressed while the rightmost digit is blinking, the leftmost
digit starts blinking again.
Repeat the above procedure to set the value of all the
digits.

5. To decide the set date and time data, press the PRESET
button.
The “HOLD” indicator on the display turns off and the date/
time display stops blinking.
The time starts counting.
Memo:
To display and set the time code or user’s bit, set the VCR
Setup Menu item No. 516 DISPLAY SELECT to “TC”.

41

6. SETTING AND ADJUSTMENTS BEFORE SHOOTING
6-1 Camera Settings
1. POWER ON
3.
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK

PRST A B

HML

GAIN

BARS CAM

SAVE STBY

VTR

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

AL
OUTPUT WHT.B

POWER

NG
ON

OFF

2.

1.
AUTO IRIS

FULL AUTO BLACK

LOLUX

POWER

NG

VTR

BA

GAIN

C

ON

OFF

AUDIO CH-2
LEVEL

2. SWITCH positions
A.
B.
C.
D.
E.

Set the VTR switch to STBY.
AUTO IRIS switch; set to NORMAL.
GAIN switch; set to L. The L position is 0 dB.
OUTPUT switch; set to CAM\AUTO KNEE OFF.
WHT. BAL (Auto White Balance) switch; set to A or B.

3. Set the lens' iris mode switch to "A" (AUTO IRIS side)
4. Choose the proper color temperature conversion filter.

PRST A B

OFF ON
AUTO KNEE

HML

STRETCH
NORMAL
COMPRESS

BARS CAM

SAVE STBY

BACK L
NORMAL
SPOT L

1 First place a charged battery pack in the battery case on
the rear section of the unit. If battery pack is not used,
connect DC power to the DC INPUT connector on the
rear section of the unit using the AC power adapter (AAP250) to supply DC 12 V current.
2 Set the POWER switch on the unit to ON.

OUTPUT

WHT.BAL

D

FILTER

E

Suitable Location

1 3200K

Indoors, dark outdoors

2 5600K

Outdoors

3 5600K+ND

Outdoors under clear sky

5. Using the SHUTTER dial, set the shutter speed to OFF.

VF

OFF
ON

4.
5.

ZEBRA
SKIN
AREA

AUTO
WHITE
ACCU
FOCUS

VTR AUDIO
LEVEL CH-1

42

TAKE

6. SETTING AND ADJUSTMENTS BEFORE SHOOTING

6-2 Viewfinder Adjustment
1. Adjust the position and angle of the viewfinder.
2. Diopter adjustment

1.
Eyepiece

Rotate the eyepiece focusing ring until the viewfinder screen
image is clearly visible.

1.

3. Brightness and contrast adjustment

2. Eyepiece

When the ambient brightness changes, etc., the brightness
and contrast of the viewfinder screen can be adjusted with
the BRIGHT and CONT controls.

focusing ring

1.
3.

3.
CONT

BRIGHT

6-3 External Monitor Adjustment
Display the camera built-in color bar signal on the video monitor
and adjust the colors, contrast and brightness.

PUSH

1. Connect a color video monitor to the MONITOR OUT

Colour video monitor

connector of the GY-DV500.
DV CAMCORDER

1.

2. Set the OUTPUT switch to BARS to output the color bar

GY-DV500

signal (SMTPE type color bars).

3. Set the monitor's BLUE CHECK function to ON so that the
LINE OUT
Y/C OUT MONITOR OUT CH-1
CH-2

SYNC IN

screen turns entirely blue.

TEST OUTPUT

VTR
REMOTE
MIC IN

3.~8.

LENS

4. Adjust the CHROMA control of the monitor so that there is
no difference in brightness between the color bars 1 and
8, 7 and D.

2.
SPOT L

5. With the BLUE CHECK function ON, adjust the PHASE
control of the monitor so that there is no difference in
brightness between the color bars 3 and 0, 5 and B.

COMPRESS

OFF
BARS CAM
AUTO KNEE
ON

PRST A B

HML

SAVE STBY

GAIN

VTR

6. If the phase control adjustment above causes a difference

T.BAL
OUTPUT WH

in brightness between the color bars 1 and 8, 7 and D,
start again from the CHROMA control adjustment in step 4.

POWER

NG
ON

OFF

7. Set the monitor's BLUE CHECK function to OFF to switch
the monitor back to the standard screen (R, G and B will all
appear).

8. Use the monitor's brightness control to adjust so that the

n SMTPE type color bars

White

Yellow

Cyan

1

2

3

Blue

8

color bars H and I disappear but J is visible.

Green Magenta

4

Black Magenta Black

9

0

A

Black

White

Black

E

F

G

Red

Blue

5

6

7

Cyan

Black

White

B

C

D

H IJ K
43

6. SETTING AND ADJUSTMENTS BEFORE SHOOTING

6-4 Back Focus Adjustment
3. 4. 6.

It is only necessary to perform this when the lens is attached
for the first time or when focusing is not correct in both the
telephoto and wide-angle positions. Adjust the viewfinder for
sharpness first.

5.

It is easier to adjust back focus when the subject is more
than 3 meters from the camera.
The optimal subject for this adjustment is a Siemens star
chart.
RET

M
A

W

T

1. Set the IRIS mode switch to M (Manual).
2. Set the zoom mode to MANU (Manual).
3. Open the iris ring. If the illumination is too strong, reduce it

1.

or move to a darker place.

MACRO

4. Turn the zoom lever until the lens is at the maximum

2.

7. 8. 10.

telephoto position.

5. Bring the subject into focus.
6. Set the lens to maximum wide-angle.
7. Loosen the back focus ring retaining knob.
8. View the same subject and adjust the back focus ring for
the best possible focus.

9. Repeat steps 4. through 8. about three times for fine
adjustment until the subject remains in focus in both the
telephoto position and the wide-angle position.

10.Tighten the back focus ring retaining knob to secure the
ring.
Memo:
ACCU FOCUS can also be used in the above step 3.

Siemens star chart

44

6. SETTING AND ADJUSTMENTS BEFORE SHOOTING

6-5 White Balance Adjustment
Since the color of light (color temperature) varies depending on the light source, it is necessary to re-adjust the white balance when
the main light source illuminating the subject changes.
Note:
When a subject illuminated by a halogen lamp with a color temperature of 3,200K is shot while the color temperature conversion
filter setting is set to 5,600K, a proper white balance adjustment and (FAW) Full Time Auto White balance may not be
accomplishable. In this case, change the color temperature conversion filter setting to 3,200K and then carry out the white
balance adjustment and (FAW) again.
● Do not adjust using any highly reflective objects, such as metal, etc., as this may result in improper white balance adjustment.

WHITE BALANCE ADJUSTMENT
2. FILTER knob

Two kinds of white balance adjustment results can be stored in
memories AUTO1 and AUTO2.
n Adjustment procedure

1. Set the following switches.

1. IRIS mode

• Set the POWER switch to ON.
• Set the OUTPUT switch to CAM-AUTO KNEE OFF.
• Set the IRIS mode switch of the lens to A (Auto).

switch

3. WHT.BAL switch
1. OUTPUT switch
1. POWER switch

5. AUTO WHT.
/ACCU FOCUS switch

A U T O WH I T E A

2. Set the FILTER knob according to the current lighting.
3. Set the WHT.BAL switch to A or B.
4. Place a white object near the centre of the screen under
the same lighting conditions as the target subject and zoom
in to fill the screen with white.

5.Tilt the AUTO WHT./ACCU FOCUS switch upward (to AUTO
A U T O WH I T E A

OP E R A T I ON

OK

During operation

Result message

WHITE) once and release it.
"AUTO WHITE A, B OPERATION" is displayed in the
viewfinder while the auto white balance adjustment circuit
operates.
"AUTO WHITE A, B OK" is displayed when the white balance
has been adjusted properly.
Error messages
• NG: OBJECT (Improper object)

A U T O WH I T E A
NG : OB J E C T

Improper object

A U T O WH I T E A
E RROR : L OW L I GH T

Insufficient illumination

Displayed when there is not enough white color on an object
or the color temperature is not suitable.
Replace the color temperature conversion filter or use another
white object and re-adjust the white balance.
• ERROR: LOW LIGHT (Insufficient illumination)

A U T O WH I T E A
E RROR : OV E R L I GH T

Excessive illumination

Displayed when the illumination is dim. Increase the
illumination and then re-adjust the white balance.
• ERROR: OVER LIGHT (Excessive illumination)
Displayed when the light is excessively bright. Decrease the
illumination and then re-adjust the white balance.

FULL-TIME AUTO WHITE BALANCE (FAW)
The FAW function adjusts the white balance value
automatically as the lighting condition changes.
This mode is convenient when you have no time to adjust the
white balance or when the camera is moved frequently in and
out of places under different lighting conditions.
n Setting procedure
The FAW function can be activated with item "FAW" on the
OPERATION MENU.
This item allows allocation of the FAW function to one of the
WHT.BAL switch positions, A, B or PRESET.
☞ See "OPERATION SCREEN" on page 73.

CAUTION:
• The FAW (Full-time Auto White balance) function cannot
provide optimum white balance with a subject outside
the FAW adjustment range, for example when it contains
only a single color or not enough white color.
• The accuracy of the FAW (Full-time Auto White balance)
is inferior to that of the manual white balance.
• When the power is turned on with the FAW mode
selected, it takes about 10 seconds for the FAW
adjustment to be completed. Do not shoot within this
interval.

45

6. SETTING AND ADJUSTMENTS BEFORE SHOOTING

6-6 Switch Settings of the VCR Section

REC/FREE

PRESET/REGEN switch

switch

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND
SHUTTER STATUS

CH-1

AUDIO
LEVEL

CH-1
CH-1
FULL AUTO BLACK

LITHIUM BATT.
B

CH-2

FREE
REC

CONTINUE

MENU

GROUP

ITEM

HOLD

SHIFT

SELECT

DATA SET

ADVANCE PRESET

PRST A

OFF ON
AUTO KNEE

BARS CAM

HML

SAVE STBY

PRESET
REGEN

FRONT
REAR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

GAIN

TC GENERATOR

CH-2
AUTO
MANUAL

MONITOR

BACK L
NORMAL
SPOT L

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

n Audio input signal selection
Use the AUDIO INPUT switch to select whether the sound
recorded on audio channel 1 or 2 is the sound from the
microphone connector on the front section or the sound from
the AUDIO INPUT connector on the rear section.
☞ See page 47.
n Audio recording level adjustment selection
Select "AUTO" or "MANUAL" for the recording level
adjustment mode for each audio channel.
☞ See page 48.
n VCR Setup Menu setting
● REMOTE SELECT
Confirm that “LOCAL” is selected if you want to operate on
the GY-DV500 only.
● BACK TALLY MODE
Select the lightning pattern of the BACK TALLY lamp.
● INPUT SELECT
Select the input video signal. To record the GY-DV500's
camera image, set to "CAMERA".
● LOW CUT IN
For each audio input connector, select whether or not the
lower frequency components of the audio signal are cut.
Set to this position to eliminate the wind noise of the
microphone.
● SAMPLING RATE
Select the sampling rate for audio recording (48 kHz or 32
kHz).
● FRONT VOLUME ENABLE
Set whether or not the front section's audio volume control
should be used. The front section's audio volume control only
affects the CH1 audio channel.
● LONG PAUSE TIME
Select the time (in minutes) until the GY-DV500 enters the
tape protection mode (drum rotation stops) when the recordpause mode is continued for long time.
● SSF MODE
Select the mode of the S.S.F. (Super Scene Finder) function.
S.S.F. function: Stores the time code of desired scenes or
cue points in the unit's memory.
☞ See “S.S.F. function” on page 60.
● DISPLAY SELECT
Select the counter display (time code or date/time indication)
when the COUNTER switch is set to “TC” or “UB”.

46

CH-1

AUDIO SELECT
AUDIO INPUT

MENU

AUTO IRIS

VTR

CH-2

COUNTER
CTL
TC
UB

ALARM

n Setting the time code recording function
The GY-DV500 records SMPTE-standard time code during
recording. Set the switches according to applications.
● To record a time code as set in the built-in time code
generator:
• Set the PRESET/REGEN switch to PRESET.
• Set the REC/FREE switch.
If it is required to record continual time codes across different
scenes, set the switch to REC.
• VCR Setup Menu setting
Select the time code generator's framing mode as drop
frame or non-drop using the VCR Setup Menu item No. 416
"NON DROP/DROP".
● To record a time code in continuation of the existing time
code on the tape:
• Set the PRESET/REGEN switch to REGEN.
For details on the time code operations including time code
presetting, see "TIME CODE OPERATION" on page 56.

6. SETTING AND ADJUSTMENTS BEFORE SHOOTING

6-7 Audio Input Signal Selection

OPERATE/WARNING
LIGHT
RESET

VF

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

CH-1
FULL AUTO BLACK

VTR

ZEBRA
SKIN
AREA

AUTO
WHITE
ACCU
FOCUS

VTR AUDIO
LEVEL CH-1

GAIN

B
PRST A

BARS CAM

HML

SAVE STBY

OFF
ON

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

CH-2 AUDIO
LINE/MIC
switch

CH-1 AUDIO
LINE/MIC
switch

MENU

L
OUTPUT WHT.BA
EARPHONE

POWER

NG
ON

DV

CH-1 AUDIO IN CH-2
LINE

DC INPUT

OFF

MIC
+48V
ON

LINE

MIC
+48V
ON

TALLY

DC OUTPUT

TAKE

Microphone input
connector

CH-1 AUDIO
INPUT
connector

AUTO
MANUAL

CH-2 AUDIO
INPUT
connector

AUDIO SELECT
AUDIO INPUT
CH-1

CH-1

AUDIO CH-2
LEVEL

CH-1 AUDIO
INPUT switch

The GY-DV500 is provided with the microphone connector on
the front section and the two AUDIO INPUT connectors at the
rear section for audio input.
On the other hand, two channels of sound can be recorded on
the tape in digital PCM format.
Using the AUDIO INPUT switch, select for each channel (CH1
and CH2) whether the sound to be recorded should be the
sound from the microphone connector on the front section or
the sound from the AUDIO INPUT connectors on the rear
section.
n Selecting the CH-1 channel input sound
Make the selection using the CH-1 AUDIO INPUT switch.
FRONT : The sound from the microphone connector on the
front section is recorded on the CH-1 channel.
REAR : The sound from the CH-1 AUDIO INPUT
connector on the rear section is recorded on the
CH-1 channel.
n Selecting the CH-2 channel input sound
Make the selection using the CH-2 AUDIO INPUT switch.
FRONT : The sound from the microphone connector on the
front section is recorded on the CH-2 channel.
REAR : The sound from the CH-2 AUDIO INPUT
connector on the rear section is recorded on the
CH-2 channel.

CH-2
FRONT
REAR

CH-2 AUDIO
INPUT switch

n Selecting the front section's microphone connector
A microphone (phantom microphone, etc.) requiring +48 V
power supply or other type of camera microphone
(monaural) can be connected.
• In accordance with the connected microphone, specify
the phantom microphone or other type of microphone
using the Camera Setup Menu item CAM MIC +48V.
• The reference input level is -60 dBs.
n Selection of rear audio input connectors
Select the audio signal input to the AUDIO INPUT connector
using the [LINE/MIC] switch. Make settings for the CH-1
and CH-2 AUDIO IN connectors separately.
LINE
: Set to this position when connected to audio
equipment, etc.
The reference input level is +4 dBs.
MIC
: Set to this position when using a monaural
microphone.
The reference input level is -60 dBs.
MIC +48 V : Set to this position when a microphone
(phantom microphone) requiring +48 V DC
power supply is connected.

CAUTION:
When connecting a component that does not require
+48 V power supply, make sure that the LINE/MIC switch
is not set to MIC +48V.
When using the microphone on the front section, set the
Camera SETUP screen item “CAM, MIC, 48V” to “OFF”.
Neglecting this could cause damage to the connected
component.

47

6. SETTING AND ADJUSTMENTS BEFORE SHOOTING

6-8 Recording Level Adjustment
CH-1 Audio
select switch

CH-2 Audio
select switch

OPERATE/WARNING
LIGHT
RESET

VF

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND
SHUTTER STATUS

AUTO
MANUAL

COUNTER
CTL
TC
UB

ALARM

AUDIO SELECT
AUDIO INPUT
CH-1

MONITOR

CH-1
MENU
CH-1
FULL AUTO BLACK

VTR

ZEBRA
SKIN
AREA

AUTO
WHITE
ACCU
FOCUS

VTR AUDIO
LEVEL CH-1

GAIN

LOLUX

B
PRST A

BARS CAM

HML

SAVE STBY

OFF
ON

CH-2
FRONT
REAR

STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

AUDIO CH-2
LEVEL

AUDIO CH-2
LEVEL

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

TAKE

CH-1 recording level control

CH-1 recording level control

For each audio channel, use the AUDIO SELECT switches to
select whether the recording level adjustment should be set to
AUTO mode or MANUAL mode.
• When set to AUTO: Recording level is fixed. In this mode,
the recording level control does not
function.
• When set to MANUAL: Recording level can be adjusted
using the recording level controls for
each audio input.
n Adjusting the recording level control of the front section
The recording level control on the front section only affects
the CH-1 channel sound.
To use the recording level control on the front section, make
the following settings.
• Set the CH-1 AUDIO SELECT switch to MANUAL.
• Set the VCR Setup Menu item No. 246 FRONT VOLUME
ENABLE to "ENABLE".
CAUTION:
The recording level controls on the side section work
regardless of the setting of the VCR Setup Menu item No.
246 FRONT VOLUME ENABLE.

CH-2 recording level control

n How to use the recording level control on
the front section
1 Set the recording level control on the front section to
maximum (10) position.
2 Initially, adjust the recording level using the CH1 recording
level control on the side.
3 When a loud sound is input during recording, use the
recording level control on the front section to lower the
recording level.
Level meter

CH 1
40 30

CH 2
32k
AUD LOCK

20

OVER
0 dB
OVER

10

48k

AUTO OFF DEW
SERVO RF L i

PB

NDF

HOLD

SP

MENU

H

M

REMAIN

S

REV FWD
H

F

E BATT F

M

Viewfinder Status 1 Mode
ACCU - FOCUS

Manual Adjustment of Recording Level

G

The recording level can be adjusted manually when the GYDV500 is in the record, record-pause or stop mode.

F

1. Set the AUDIO SELECT switch of the channel whose

I
SD
B

recording level that you want to adjust manually to MANUAL.

2. Rotate the recording level control corresponding to the audio
input to be adjusted.
• Adjust so that the peak level does not exceed the -3dB
point when a loud sound is input.
• With microphone input, since the limiter circuit is activated,
the recording level will not exceed 0 dB even if the
recording level control is turned up.

CH1
CH2

F5 . 6
STBY

- - - -+- - - - -+- < 60

M 09 9
1 2 . 4V

Audio leve
Indicator level (reference)
–38

–32

–26

–20

–14

–8 –2dB

CAUTION:
When the AUDIO INPUT LINE/MIC switch on the rear
section is set to MIC, be sure to check that the microphone
is connected to the AUDIO INPUT connector. If the
microphone is not connected, increasing the recording level
could cause noise from the input connector to be recorded
on the tape. When the microphone is not connected to the
AUDIO INPUT connector on the rear panel, set the LINE/
MIC switch to LINE or turn down the recording level control.

48

6. SETTING AND ADJUSTMENTS BEFORE SHOOTING

6-9 Monitoring Audio during Recording

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK

HML

SAVE STBY

GAIN

OFF
BARS CAM
AUTO KNEE
ON

VTR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

PRST A B

AUTO IRIS

AL
OUTPUT WHT.B

POWER

NG
ON

OFF

EARPHONE
jack
ALARM
control

MONITOR
control

MONITOR SELECT
switch
Monitoring
loudspeaker

The audio input during recording, in record-pause or stop mode
can be monitored through the monitoring loudspeaker or
earphone.
• The monitoring audio is not output from the loudspeaker while
the EARPHONE jack is in use.
• Select the audio channel to be monitored using the MONITOR
SELECT switch.
CH-1 : The sound input to the CH-1 channel is output.
MIX : The sound input to the CH1 and CH2 channels is
output mixed.
CH-2 : The sound input to the CH-2 channel is output.
• The MONITOR volume control adjusts the monitoring
volume.
• The loudspeaker or earphone outputs an alarm tone in the
case of an abnormal condition occurring in the unit.
An alarm tone is also output when the tape end is reached
or when the battery is running down. The alarm tone volume
can be adjusted with the ALARM control. For details on the
alarm tone, see page 87.
* Do not increase the audio monitoring volume excessively;
otherwise howling with the camera microphone may
occur.

49

7. SHOOTING OPERATION
7-1 Basic Recording Operation
1. “DEW”
CH 1
40 30

20

CH 2
32k
AUD LOCK

3.

AUTO OFF DEW

OVER
0 dB
OVER

10

48k

SERVO RF L i

PB

NDF

HOLD

SP

MENU

H

M

S

Power is supplied to the unit.
Check that the condensation indicator "DEW" does not
appear on the display. If it is lit, wait until the indicator goes
out.

F

2. Set the VTR switch to the STBY position.

Eject switch

EJECT

1. Set the POWER switch to ON.

5.
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

Even when the VTR switch is set to the "SAVE" position,
pressing the VTR trigger button will start recording.
However, in this case, it is necessary to wait a short time
until the recording actually starts.
For details on the SAVE mode, see page 52.

MONITOR

MENU

3. Slide the EJECT switch to open the cassette cover.

CH-1 AUDIO CH-2

LEVEL
FULL AUTO BLACK

LOLUX
STRETCH
NORMAL
COMPRESS

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

SKIN
AREA

OFF

2.

ZEBRA
AUTO
WHITE

• Ensure that the switch on the back of the videocassette
is set to REC and insert the cassette correctly.
When the cassette is inserted, the tape is loaded and
the unit enters the record-pause mode.
• Slowly close the cassette cover.

B

OFF ON
AUTO KNEE

HML

SAVE STBY

GAIN

VTR

BARS CAM

BACK L
NORMAL
SPOT L

PRST A

AUTO IRIS

4.

ACCU
FOCUS

B
PRST A

T.BAL
OUTPUT WH

GAIN

VTR

OFF ONE
AUTO KNE

SAVE STB

6.

BARS CAM

TAKE

Y

LEVEL CH-1

HML

VTR AUDIO

POWER

NG
ON

OFF

1.

• Use a videocassette marked MiniDV.
• If the cassette cover is not closed, the GY-DV500 will
remain inoperative.
• Following loading of the cassette and when the POWER
switch is turned ON/OFF, the built-in head cleaner will
emit a sound while operating. This does not indicate a
malfunction.
• After the cassette cover is closed, it takes about 8
seconds before the unit is ready for recording.

4. Set the switches as required.
• GAIN
: Sensitivity suitable for the subject
• OUTPUT : "CAM/AUTO KNEE ON"
• WHT-BAL : "A" or "B"
• Set the IRIS switch of the lens to "A".

5. Select the FILTER according to the lighting condition.
RET

Position 1 (3200K) : For shooting indoors or outdoors when
illumination is not sufficient
Position 2 (5600K) : For shooting outdoors
Position 3 (5600K + ND):
For shooting outdoors under a clear
sky.

M
A

W

T

4.

6. Adjust the white balance.
☞ See "White Balance Adjustment" on page 45.

7. Point the camera at the subject and determine the angle of
view and focus with the zoom lever and the focusing ring.

MACRO

7.

50

7. SHOOTING OPERATION

7-1 Basic Recording Operation (Cont'd)
8. 9. 10.
VTR trigger button

8. Press the VTR trigger button on the GY-DV500 or lens to
start recording.
Once recording has started, the BACK TALLY lamp on the
rear section of the unit and the tally lamp on the viewfinder
light red, and the REC indication in the viewfinder lights
green.
Note:
* The lightning conditions of the BACK TALLY lamp on
the rear section of the unit can be changed by setting
the VCR Setup Menu item No. 082 BACK TALLY MODE.
* The lamp in the viewfinder and on the front section will
blink from when the button is pressed and until recording
actually starts.

9. To stop recording, press the VTR trigger button again. The
TALLY lamp and REC indicator lamp go out and the unit
enters the record-pause mode.
When the VTR trigger button is pressed, the unit enters the
record-pause mode after rewinding the tape for about 2
seconds (back-spacing).

8. TALLY lamp
OFF
ON

ZEBRA
SKIN
AREA

AUTO
WHITE
ACCU
FOCUS

VTR AUDIO
LEVEL CH-1

10. To restart recording:

TAKE

Press the VTR trigger button on the GY-DV500 or lens.

11.
GAIN

B

8. 9. 10.

PRST A

OFF ONE
AUTO KNE

HML

Y
SAVE STB

VTR

BARS CAM

11. Ending recording:
T.BAL
OUTPUT WH

VTR trigger button
POWER

NG
ON

OFF

Enter record-pause mode and perform the following
operations as required.
n When it is required to unload the videocassette:
• Slide the EJECT switch.
n When it is required to put the unit in save mode:
• Set the VTR switch to SAVE.
Drum rotation stops and the GY-DV500 enters the tape
protection/power-saving mode.

12. When shooting is completely finished, eject the cassette

12.

and set the POWER switch to “OFF”.
When the unit is not going to be used for a long period,
detach the battery pack.

About the QUICK REC START Mode
REC
BATT

ALARM

8.

If the VTR trigger button is pressed immediately after the
videocassette is inserted, the mode becomes the QUICK
REC START mode that enables quick start of recording.
However, when shooting starts in the middle of the tape, a
blank space appears as the new scene will not be linked
smoothly with the previous image.
Also, the time code does not continue. (Some overlap may
also occur.)

8. TALLY lamp
Note:
● The unit enters stop mode at tape-end automatically, and if kept longer than 3 or 30 minutes in this mode, SAVE mode is
maintained. ☞ See “Menu No. 307: LONG PAUSE TIME” on page 69.
● If the VTR trigger button is pushed very quickly and repeatedly, or the POWER switch is moved immediately after being
pressed, the viewfinder REC indicator lamp may blink and the GY-DV500 may not enter the record mode. To remedy this
condition set the POWER switch to OFF and wait for 5 seconds or more before turning the power on again.
● A neat transition to the next recorded scene cannot be guaranteed if you end a recording by turning the POWER switch
or DC power supply OFF, or by removing the battery pack.
● Before recording a scene that is particularly important, perform test shooting to ensure that normal recording is possible.
● The power consumption can be reduced by setting the LIGHT switch on the display and TALLY lamp to OFF.
● The microphone may pick up the sound of the lens’ iris if the iris is changed abruptly or the iris is manually moved abruptly
during recording. If you find the noise annoying, please purchase an optional microphone in order to move the microphone
away from the lens or ensure that the iris is not changed abruptly during shooting.
51

7. SHOOTING OPERATION

7-2 VCR Save Mode
When a recordable videocassette is loaded, the GY-DV500
enters the record-pause mode. However, the record-pause
operation condition differs depending on the setting of the VTR
switch.

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

● VTR switch setting

MENU
CH-1 AUDIO CH-2

LEVEL
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

LOLUX
STRETCH
NORMAL
COMPRESS

OFF
BARS CAM
AUTO KNEE
ON

OUTPUT WHT.BAL

POWER

GAIN

VTR

B
PRST A

Y
SAVE STB

VTR
switch

OFF

HML

ON

OFF ONE
AUTO KNE

SAVE STBY

NG

BARS CAM

HML

GAIN

B

VTR

PRST A

AUTO IRIS

T.BAL
OUTPUT WH

POWER

NG
ON

OFF

Viewfinder
ACCU - FOCUS

STBY : The GY-DV500 enters the record-pause mode, and
the drum is rotating at this time. (Standby mode)
The "STBY" indicator appears in the VCR operation
status display in the viewfinder (in Status 1 mode).
• In this condition, recording starts immediately when
the VTR trigger button is pressed.
SAVE : The GY-DV500 enters the record-pause mode but
the drum is not rotating. (Save mode).
The tape is protected.
The "SAVE" indicator appears in the viewfinder (in
Status 1 mode).
The OPERATE indicator lights orange. The display
backlight turns off.
Note:
When the VCR Setup Menu item No. 396 SSF MODE is
set to the CUE MODE or MARK mode, the VCR save
mode is not entered.

G
F
I
SD
B

VCR operation
status display
STBY
or
SAVE

F5 . 6
STBY

CH1
CH2

- - - -+- - - - -+- < 60

M 09 9
1 2 . 4V

(Status 1 mode)

Recording from the Save mode
● In the save mode, pressing the VTR trigger button will start
recording.
However, in this case, it takes several seconds before the
GY-DV500 starts recording.
● Pressing the VTR trigger button again interrupts the recording
and the GY-DV500 enters the save mode again.

7-3 If Unit is Left in Record-Pause (Standby) Mode
When the GY-DV500 has remained in record-pause (standby)
mode for about 30 minutes, the unit enters the save mode, in
which the drum rotation is stopped automatically and the tape
tension is released. (Save mode)
n To start recording from the save mode, press the VTR trigger
button; the drum starts to rotate and recording starts in about
3 seconds.
n To return to the record-pause mode from the save mode,
press the VTR trigger button TWICE; the drum starts to rotate.

52

• The time until the unit enters the save mode after it is
placed in record-pause mode can be set to 3 minutes or
30 minutes with the VCR Setup Menu item No. 307 LONG
PAUSE TIME.
When used in a cold environment, the setting will be 3
minutes regardless of the setting on the VCR Setup
Menu.
☞ See page 69.

7. SHOOTING OPERATION

7-4 Checking Recorded Contents in Record-Pause Mode (Recording Check Function)
The recording check function is only valid in the standby mode
(VTR switch set to STBY).
In the record-pause mode, approximately 2 seconds of the last
recorded portion can be played back.

1. RET button

• The recorded contents can be checked in the viewfinder or
on a monitor connected to the MONITOR OUT or Y/C OUT
connectors.
• In the viewfinder or on the monitor connected to the
MONITOR OUT or Y/C OUT connectors, the video image
from the VCR section is output.

1. In the record-pause mode, press the RET button on the

* This function does not work when the GY-DV500 is in
the save mode or stop mode.
* During recording check, the following indications will
appear if the error rate increases due to head clogging,
etc.
• “RF” appears on the display panel.
• “HEAD CLOG” appears on the counter display.
• “VTR WARNING (HEAD)” appears in the viewfinder.

camera lens section.
• The tape is slightly rewound and played back for approximately 2 seconds.
After playback is finished, the tape returns to the position
at which the RET button is pressed and the record-pause
mode resumes.
n When the RET button is kept pressed, the tape is rewound
and played back for approximately 10 seconds at maximum.
• While the RET button is pressed, the record-mode is not
entered even if the VTR trigger button is pressed.

53

8. PLAYBACK MODE
8-1 Playback Procedure
2.
2. EJECT switch
EJECT
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

LOG

MENU
CH-1
FULL AUTO BLACK

GAIN

STOP

FF

PLAY

STILL

B
PRST A

BARS CAM

HML

SAVE STBY

VTR

REW

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

6. STOP button
1. POWER switch

4. STILL button
3. PLAY button
5.

Operation

1. Set the POWER switch to ON.
2. Load the recorded videocassette correctly.
• Slide the EJECT switch to the side. When the cassette
cover opens, insert the videocassette and then close the
cassette cover again.
n When a recordable videocassette (with the switch on the
back of the cassette set to REC) is loaded, the unit enters
the record-pause mode (STBY mode).
In this case, press the STOP button to release the recordpause mode.

3. Press the PLAY button.

a The PLAY indicator lights and playback starts.

4. Press the STILL button to stop playback temporarily.

a The STILL indicator lights and the unit enters the still
mode.

5. To re-start playback, press the PLAY button.

a The STILL indicator goes out and playback starts again.

6. To stop playback, press the STOP button.

a The PLAY indicator goes out and the unit enters the
stop mode.

54

CAUTION:
• When the still picture mode or stop mode has continued
for about 30 minutes, the unit automatically switches to
the save mode to protect the tape.
The time until the tape protect mode is initiated can be
set to 3 or 30 minutes with the VCR Setup Menu item
No. 307 LONG PAUSE TIME.
When used in a cold environment, the setting will be 3
minutes regardless of the setting on the VCR Setup
Menu.
• Noise may appear in the picture during still mode.
• When the automatic tracking function is activated at the
start of the playback mode, digital noise may appear on
the playback image.
• This unit does not allow manual tracking adjustment.
• When playing back a tape recorded on another unit,
digital noise may appear during playback.
• Following the loading, the built-in head cleaner will emit
a sound while operating. This does not indicate a
malfunction.

8. PLAYBACK MODE

8-2 Fast-Forward, Rewind
REW button FF button

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

LOG

REW

STOP

FF

PLAY

STILL

MONITOR

MENU
CH-1
FULL AUTO BLACK

B

OFF ON
AUTO KNEE

BARS CAM

HML

SAVE STBY

L
OUTPUT WHT.BA

GAIN

VTR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

PRST A

AUTO IRIS

POWER

NG
ON

OFF

STOP button

n Press the FF button in stop mode to fast forward the tape.
Press the REW button in stop mode to rewind the tape.
n Press the STOP button to stop fast forwarding or rewinding.

• When the tape approaches the end during fast forwarding
or rewinding, the tape speed decelerates to protect the
tape.
• The time required for fast forwarding and rewinding may
become longer when used in a cold environment. This is
not a malfunction.

8-3 Search
REW button FF button

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

LOG

REW

STOP

FF

PLAY

STILL

MONITOR

MENU
CH-1
FULL AUTO BLACK

GAIN

B
PRST A

BARS CAM

HML

SAVE STBY

VTR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

STOP button PLAY button

n Press the FF button in play mode to search the tape in the
forward direction at about 10 times the normal speed.
• Press the REW button in play mode to search the tape in
the reverse direction at about 10 times the normal speed.

• The audio is reproduced during the search.
• Video noise may be observed or the image may become
unstable during the search, but this is not a malfunction.

n Press the PLAY button to resume normal playback.
n Press the STOP button to stop.

55

9. TIME CODE OPERATION
The GY-DV500 records SMPTE-standard time codes and user's bits. In the play or the record mode, the reproduced time codes or
user's bits are shown on the counter display.
• Time code data cannot be output through the unit's connectors.

9-1 Displaying Time Code

Hour Min. Sec. Frame

Time code display
OPERATE/WARNING
CH 1

RESET

40 30

20

OVER
0 dB
OVER

10

CH 2

MONITOR
SELECT

32k
AUD LOCK

48k

SERVO RF L i
NDF

LIGHT

M

S

F

User’s bit display

ON
OFF

HOLD

SP

MENU

H

M

REMAIN

ALARM

AUTO OFF DEW

PB

H

S

REV FWD
H

F

E BATT F

M

COUNTER
CTL
TC
UB

COUNTER switch

MONITOR

CH-1 AUDIO CH-2

LEVEL
LOLUX

The selected time codes can be shown on the counter display
during playback and recording as follows.
n Set the VCR Setup Menu item No. 516 DISPLAY SELECT to
“TC”.
☞ See page 69.

PRST

T.BAL

F

n Set the COUNTER switch to "TC" or "UB".
TC: Time codes are displayed.
UB: User's bit data of time codes are displayed.

9-2 Presetting and Recording of Time Code
The time code or user's bit data to be recorded onto the tape can be preset to a desired value.
PRESET/REGEN
switch
CH-1

AUDIO
LEVEL

REC/FREE
switch

CH-2
CH-1

TC GENERATOR

CH-2
PRESET
REGEN

AUTO
MANUAL

AUDIO SELECT
AUDIO INPUT

CH-1

CH-2

FREE
REC

CONTINUE

MENU

FRONT
REAR

LITHIUM BATT.

GROUP

ITEM

HOLD

SHIFT

SELECT

DATA SET

ADVANCE PRESET

Drop frame/Non-drop frame mode
In the NTSC system, the actual number of frames per 1
second is approximately 29.97 frames, but the number of
frames that becomes the processing reference of the time
code is 30 frames. To compensate for this difference, the
mode called drop mode drops frame 00 and 01 for every
minute that cannot be divided by 10.
The non-drop frame mode is when no frames are dropped
and the actual time shift is neglected.
Note:
When the VCR Setup Menu item No. 398 SSF MODE is set
to CUE MODE or MARK MODE, the time code generator’s
running method is internally set to the REGEN mode.
When this is the case and you want to enter the preset
mode, set the VCR Setup Menu item No. 398 SSF MODE
to "OFF", or set the PRESET/REGEN switch to the
PRESET position again.

56

n Setting the time code related switches
• Set the PRESET/REGEN switch to "PRESET".
• Set the REC/FREE switch.
REC : The data preset in the time code generator runs
only during recording.
Use this setting if it is required to record continual
time codes across different scenes.
* However, approximately ±1-frame variations may
occur in scene transition accuracy.
FREE : The time code starts to run from the time it is preset
in the time code generator.
n Setting the VCR Setup Menu
• Set the VCR Setup Menu item No. 516 DISPLAY SELECT to
“TC”.
Select the time code generator's framing mode using the VCR
Setup Menu item No. 416 NON DROP/DROP.
DROP
: The time code generator's running method is set
to the drop frame mode.
Use this setting when placing emphasis on the
recording time.
The “DF” indicator lights up on the display in the
drop-frame mode.
NON DROP : The time code generator's running method is set
to the non drop frame mode.
Use this setting when placing emphasis on the
number of frames.
In the NON DROP frame mode, the "NDF" indicator lights on
the display.
NDF

H

M

S

F

9. TIME CODE OPERATION

TIME CODE PRESETTING PROCEDURE

2. HOLD button
CH-1

4. SHIFT button

CH-2

AUDIO
LEVEL

CH-1

TC GENERATOR

CH-2
PRESET
REGEN

AUTO
MANUAL

AUDIO SELECT
AUDIO INPUT

CH-1

CH-2

Press the HOLD button.
• The "HOLD" indicator lights on the display to indicate
the preset mode. The first digit of the counter display
blinks.

MENU

FRONT
REAR

LITHIUM BATT.

GROUP

ITEM

HOLD

SHIFT

SELECT

Set the COUNTER switch to "TC".
• Time code up to 23 hrs. 59 min. 59 sec. 29 frames can be
preset.

2. Place the time code generator in preset mode.

FREE
REC

CONTINUE

1. Display the time code on the counter display.

DATA SET

ADVANCE PRESET

3. Set the value of the blinking digit.
6.

3. ADVANCE

PRESET
button

button

M

S

F

5. Set the desired value for all digits.

HOLD

H

M

S

Repeat steps 3. and 4. for each digit.

F

6. Preset the set data in the memory.
Press the PRESET button.
• The set data is saved as the time code generator value.
Following the above operation, the "HOLD" indicator
disappears from the display, the counter stops blinking
and the time code is preset.
• If the REC/FREE switch is set to FREE, the time code
starts to run.

HOLD

H

M

S

F
HOLD

H

M

4. Change the blinking digit.
Press the SHIFT button.
• The blinking digit changes.

HOLD

H

Press the ADVANCE button.
• The value of the blinking digit changes.

S

F

n If you preset a wrong time code, perform steps 2. 3. 4. 5. and
6. again.
Note:
Time code presetting is not possible in the SAVE mode.

PRESETTING USER'S BIT DATA
RESET button
OPERATE/WARNING
RESET

CH 1
40 30

20

OVER
0 dB
OVER

10

CH 2

MONITOR
SELECT

32k
AUD LOCK

48k

PB

AUTO OFF DEW
SERVO RF L i
NDF

LIGHT
ON
OFF

HOLD

n Display user's bit data on the counter display and perform
the same procedure as the time code presetting procedure.
• The user's bit can be specified using numerals or alphabetic
letters from 0 to F for each digit.

SP

MENU

H

M

REMAIN

REV FWD
H

M

S

F

E BATT F

COUNTER
CTL
TC
UB

Note:
Do not set “F” to all user's bit, or the data can not be read.

• Pressing the RESET button in the preset mode resets
the time code or user's bit data to 00 00 00 00.
• If you press the HOLD button by mistake, press the HOLD
button once more to return to the previous display.

57

9. TIME CODE OPERATION

9-3 Recording Time Codes in Continuation of Time Codes Recorded on Tape
The GY-DV500 also incorporates a time code reader. Therefore, when the unit enters record mode from record-pause mode, it can
read the time code data recorded on the tape and record time codes in continuation of the existing data. The recorded user's bit
data is identical to the user's bit data recorded on tape.
* However, approximately ±1-frame variations may occur in scene transition accuracy.
To enable this, set the time code related switches as follows before starting recording.

PRESET/REGEN switch
CH-1

AUDIO
LEVEL

CH-2
CH-1

TC GENERATOR

CH-2
PRESET
REGEN

AUTO
MANUAL

AUDIO SELECT
AUDIO INPUT

CH-1

CH-2

FREE
REC

CONTINUE

MENU

FRONT
REAR

LITHIUM BATT.

58

GROUP

ITEM

HOLD

SHIFT

SELECT

DATA SET

ADVANCE PRESET

Setting
n Set the VCR Setup Menu item No. 516 DISPLAY SELECT to
“TC”.
☞ See page 69.
n Set the counter display to show time codes or user's bit data.
n Set the PRESET/REGEN switch to REGEN.
• The time code run mode becomes unrelated to the REC/
FREE switch settings.
• The time code framing mode automatically becomes the
mode (drop frame or non drop frame) already recorded on
the tape.

9. TIME CODE OPERATION

9-4 Reproducing Time Codes
The GY-DV500 incorporates a time code reader. During playback, the time code or user's bit data recorded on the tape is displayed
on the counter display.

n Set the VCR Setup Menu item No. 516 DISPLAY SELECT to
“TC”.
☞ See page 69.
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

n Reproducing time codes
Press the PLAY button.
• The “PB” indicator lights up on the display and the time
code or userís bit data are indicated.

MONITOR

MENU
CH-1
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

PRST A B

HML

GAIN

BARS CAM

SAVE STBY

VTR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

OFF ON
AUTO KNEE

AUTO IRIS

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

• When passing sections where the time code does not
continue during playback, the time code stops running.
The playback mode continues.

PB

H

n Set the counter display to indicate time code or user's bit
data.

M

S

F

Note:
Time code more than two hours can not be displayed
correctly by consumer DV equipment, which has no
capability to display more than two hours.

59

10. S.S.F. (Super Scene Finder) FUNCTION
10-1 Explanation of the S.S.F. Function
During recording, the SSF function records the time code data at the point of time of a desired recorded scene in the unit's memory.
Using the S.S.F. data stored in memory during after-processing of the recorded image allows efficient use of the tape.
The S.S.F. function comprises the two modes CUE and MARK. Select the mode using the VCR Setup Menu item No. 398 S.S.F.
MODE.
When the VCR Setup Menu item No. 398 SSF MODE is set to CUE MODE or MARK MODE, the time code generator’s running
method is internally set to the REGEN mode.
When shooting in either of the modes, the time code data is stored in the unit's memory when the TAKE button on the front section
is pressed.
n CUE Mode:
When the TAKE button is pressed at the desired scene during shooting of a given cut, the time code data at that point is stored
as CUE data in the unit's memory. The time code data at the time when recording is started or stopped with the VTR TRIGGER
button are stored in the unit's memory as scene data.
Scene
Shooting started
with VTR trigger

5 sec or more

REC start
IN
time code data

5 sec or more

REC pause

CUE 1
time code data

CUE 2
time code data

CUE 3
time code data

TAKE button

TAKE button

TAKE button

OUT
time code data

Note:
• Leave an interval of at least 5 seconds between memorization of CUE data.
If the TAKE button is pressed within 5 seconds from the previous point, the new point is not memorized.
• In the CUE mode, time code log data stored on the camera memory may differ from the actual time code recorded on tape at
the time of pressing the TAKE button. This difference may be within 3 frames and it is not a malfunction.
n MARK MODE
During shooting of a given cut, press the TAKE button at beginning of a desired scene and then press the TAKE button again at
the ending of the scene.
The time code data at the point where the TAKE button is pressed first becomes the start point of the scene and time code data
at the point where the TAKE button is pressed the second time becomes the ending point, and both are stored in the unit's
memory.
Cut
Shooting started
with VTR trigger

REC start

REC pause
IN
time code data

OUT
time code data

IN time
code data

Scene 1

TAKE button

TAKE button

OUT
time code data
Scene 2

TAKE button

TAKE button

• In the MARK mode up to 119 scenes can be stored in memory. When the memory becomes full, the indication showing the
number of recorded scenes on the viewfinder screen becomes “M: - - -”.
However, if mixed with the CUE mode, the maximum number of scenes that can be stored decreases for each scene.
• In the CUE mode up to 237 points can be stored in memory.
However, for each REC start/stop the maximum number of points that can be stored decreases by two points for each scene.
The same is true when the CUE mode is mixed with the MARK mode.
• When recording in the S.S.F. mode, the reel number (cassette number) for each cassette is recorded in the memory of the
GY-DV500 and on tape.
• When the videocassette is replaced, new S.S.F. data is generated. S.S.F. data for six videocassettes can be stored in the
internal memory.
• Before recording the seventh cassette in the S.S.F. mode, be sure that necessary data has been transferred from the
memory to the non-linear editing controller or other component, or write data to the tape for each recording. See page 63.
Note:
• When recording is not performed in the S.S.F. mode, be sure to set the VCR SETUP MENU item No. 398 SSF MODE to OFF.
• Be sure to record S.S.F. data continuously on the same tape. It is not possible to rewind the tape for overwriting during the
recording.
If the tape is rewound in the middle of a recording, or after similar operation is performed, be sure to use the Scene End Cue
Up function in order to ensure that new data are recorded in continuation of the existing data.
☞ See “About the Scene End Cue Up Function” on page 63.
• In the S.S.F. mode, the STBY/SAVE switch does not activate the VTR save mode. (The save mode is activated by a long pause.)

60

10. S.S.F. (Super Scene Finder) FUNCTION

10-2 How to Use the S.S.F. Function

VF

OFF
ON

ZEBRA
SKIN
AREA

AUTO
WHITE
ACCU
FOCUS

VTR AUDIO
LEVEL CH-1

TAKE button

TAKE

VTR trigger button

MARK Mode
1. Set the S.S.F. mode as MARK mode.

CUE Mode
1. Set the S.S.F. mode as CUE mode.
Set the VCR Setup Menu item No. 398 S.S.F. MODE to
"CUE".
☞ See page 69.
• The CUE mode is indicated in the lower part of the Status
1 screen in the viewfinder.

F5 . 6
STBY

CH1
CH2

Set the VCR Setup Menu item No. 398 S.S.F. MODE to
"MARK".
☞ See page 69.
• The MARK mode is indicated in the lower part of the
Status 1 screen in the viewfinder.

ACCU - FOCUS

ACCU - FOCUS

G

G

F

F

I
SD
B

I
SD
B

- - - -+- - - - -+- < 60

C 09 9
1 2 . 4V

CUE mode
Number of
memorized
scenes
* This indicator
is not indicating the number
of the CUE
point.

2. Press the VTR trigger button to start the recording.
3. When you reach the point that you want to memorize as
the CUE point, press the TAKE button.
• The time code data of the point where the TAKE button is
pressed is stored in the unit's memory as CUE data.
The LOG button’s LED lights during memorization of the
CUE point and the “∗” mark is shown in the viewfinder.
n Press the TAKE button each time you reach a point that
you want to memorize as CUE data.

4. Stop the recording.
Press the VTR trigger button.

F5 . 6
STBY

CH1
CH2

- - - -+- - - - -+- < 60

M 09 9
1 2 . 4V

MARK mode
Number of
memorized
scenes

2. Press the VTR trigger button to start the recording.
3. When you reach the scene that you want to memorize, press
the TAKE button.
• The time code data of the point where the TAKE button is
pressed is stored in the unit's memory as the start point
of the scene.
4. When you reach the scene that you want to memorize as
the ending point, press the TAKE button again.
• The time code data of the point where the TAKE button is
pressed is stored in the unit's memory as the ending point
of the scene.
• The LOG button’s LED lights during memorization of the
IN point and the “∗” mark is shown in the viewfinder.
The LOG button’s LED remains off during memorization
of the OUT point and the “∗” mark is not shown in the
viewfinder.
n For each scene that you want to memorize, repeat steps
3. and 4.
5. Stop the recording.
Press the VTR trigger button.

Note:
• Once the S.S.F. data has been written to a videocassette, it is not possible to record S.S.F. data to the tape again.
• Once a tape with recorded S.S.F. data is rewound but not ejected before playback or recording is performed on it again, the
previous S.S.F. data cannot be automatically erased when S.S.F. data are recorded (when you overwrite the previous image).
Therefore, the S.S.F. data of the overlapped sections will not correspond to the video image.
Furthermore, please note that the time code data may differ from the actual data if recording is started in the CUE mode in
this situation.

61

10. S.S.F. (Super Scene Finder) FUNCTION

10-3 Deleting S.S.F. Data
The S.S.F. data recorded in the unit's memory can be deleted
in the record mode and the record-pause mode.
This function is only valid in the MARK mode.
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
AUTO IRIS

FULL AUTO BLACK

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

ON
PRST A B

CAM
AUTO KNEE BARS
OFF

L
OUTPUT WHT.BA

HML
SAVE STBY

GAIN

VTR

POWER

NG
ON

OFF

n In the record mode, press the NG button after the IN point
has been stored or after the scene has been stored.
• The S.S.F. data of the cut that you are currently shooting is
deleted.
When the NG button is pressed after the IN point has been
stored, the scene number is not updated.
* The S.S.F. data of previous cuts are not deleted.
n In the record-pause mode, press the NG button.
At the point when the TAKE button is used to store the next
scene, the S.S.F. data of the immediately preceding cut is
deleted.

NG button

Note:
The NG button is only valid for the immediately preceding
scene. The erase of scene data by the NG button cannot
be confirmed on the unit.

10-4 Resetting S.S.F. Data
Operation
LOG

2.

REW

STOP

LOG button

FF

1.

PLAY

STILL

STOP button

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK

PRST A B

HML

GAIN

BARS CAM

SAVE STBY

VTR

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

2.

62

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

RESET button

1. Press the STOP button to enter the stop mode.
2. Press the RESET button while the LOG button is kept
pressed.
• All the S.S.F. data held in the memory are erased.
However, the reel number is not cleared.

Note:
The unit is not provided with a function for reading out
the S.S.F. data from a tape.
Necessary data should be moved to another device
before resetting. Also, to read out the S.S.F. data from a
tape, please use the optional DV Videocassette
Recorder BR-DV600.

10. S.S.F. (Super Scene Finder) FUNCTION

10-5 Writing S.S.F. Data to Tape
S.S.F. data stored in the unitís memory can be written to the
beginning of tape.
LOG

REW

STOP

FF

PLAY

Precautions when writing S.S.F. data

STILL

When S.S.F. data stored in the memory of the GY-DV500 is
written to the beginning of the rewound tape, approximately 5
seconds of recorded video and/or sound will be erased at the
beginning.
In the case of important recordings, leave 5 seconds or more
of the tape unrecorded before starting recording.

1. STOP button
2. LOG button 2. REW button

Operation

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

1. Press the STOP button to enter the stop mode.
2. Press the REW button while the LOG button is kept pressed.

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK

• The REW indicator blinks during tape transport in the
writing position.
The LOG indicator lights while S.S.F. data are being
written to the tape.
• When writing to the tape is completed, the LOG indicator
goes out.

PRST A B

HML

GAIN

BARS CAM

SAVE STBY

VTR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

L
OUTPUT WHT.BA

POWER

NG
ON

CH-1

OFF

AUDIO
LEVEL

CH-2
CH-1

TC GENERATOR

CH-2
PRESET
REGEN

AUTO
MANUAL

AUDIO SELECT
AUDIO INPUT

CH-1

CH-2

FREE
REC

CONTINUE

MENU

FRONT
REAR

LITHIUM BATT.

GROUP

ITEM

HOLD

SHIFT

SELECT

About the Scene End Cue Up Function

DATA SET

ADVANCE PRESET

n When the CONTINUE button is pressed while the LOG
button is kept pressed in the stop mode, the tape winds
to the S.S.F. data’s last OUT point, after which the unit
enters the record-pause mode. (Scene End Cue Up)
The FF button’s LED blinks during the Scene End Cue
Up mode.

CONTINUE button

Note:
Once a tape with recorded S.S.F. data is ejected and then
reinserted again, the previous data will be erased if new
S.S.F. data are recorded on the tape.

10-6 Outputting S.S.F. Data
The S.S.F. data stored in the unit's memory can be output by
RS-232C control via the VTR REMOTE connector.
For how to connect, see
“Connecting a PC” on page 65.

PUSH

DV CAMCORDER

GY-DV500

LINE OUT
Y/C OUT MONITOR OUT CH-1
CH-2

SYNC IN

TEST OUT

VTR
REMOTE
MIC IN
LENS

VTR REMOTE connector

63

11. USING EXTERNAL COMPONENTS
11-1 Connecting a Video Component with DV Connector
Rear section of GY-DV500

Video component with DV Connector
EARPHONE

DV

CH-1 AUDIO IN CH-2
LINE

DC INPUT

MIC
+48V
ON

LINE

MIC
+48V
ON

TALLY

DC OUTPUT

DV connector

DV connector

DV cable
When connecting the GY-DV500 to a non-linear editing controller or other component with DV connector, be sure to observe the
following procedure.
n When using the GY-DV500 as playback component

n When using the GY-DV500 as recording component

1. Turn ON both units.
2. Confirm that the VCR Setup Menu item No.126 INPUT

1. Turn ON both units.
2. Set the VCR Setup Menu item No.126 INPUT SELECT to

SELECT is set to “CAMERA”(cA).
* If set to “IEEE1394”, set it to “CAMERA” and then turn
ON the power again.

3. Insert the videocassette.
4. Connect the DV cable.
Memo:
When the GY-DV500 is controlled through the DV
connector, set the VCR Setup Menu item No.050
REMOTE SELECT to “IEEE1394”.
However, the following functions may not work
depending on the component that the GY-DV500 is
connected to.
• REC
• FF (FWD search is possible)
• REW (REV search is possible)

“IEEE1394”(iE).

3. Insert the videocassette.
4. Connect the DV cable.
Memo:
• When recording while controlling the GY-DV500
through the DV connector from another component
with DV connector, set the VCR Setup Menu item
No.050 REMOTE SELECT to “IEEE1394”.
In this case, it takes approximately 2 to 3 seconds
before recording starts on the GY-DV500.
• When video is input through the DV connector, the
EE picture is not displayed in the viewfinder.
n When the GY-DV500 is used as camera, and a backup
recording is made on another component via the DV
connector, set the VCR Setup Menu item No.126 INPUT
SELECT to “CAMERA”.

Note:
If the above procedure is not performed correctly, the playback picture may be disturbed or the sound may fall out. If this
happens, redo the connection by performing steps 1. to 4. described above.

64

11. USING EXTERNAL COMPONENTS

11-2 Connecting a PC
PUSH

DV CAMCORDER

GY-DV500

RS-232C
DV connector

LINE OUT
Y/C OUT MONITOR OUT CH-1
CH-2

SYNC IN

TEST OUT

VTR
REMOTE

PC

MIC IN
LENS

VTR
REMOTE connector

MONITOR
OUT
connector

AUDIO OUT

TTL RS-232C
converter cable
(Optional VC-P893)

RS-232C

AUDIO IN
VIDEO IN
Non-linear editing controller
DV connector

Connections
Connect the GY-DV500's VTR REMOTE connector to the RS-232C connector on the PC or the non-linear editing controller using
the TTL ⇔ RS-232C converter cable.
Or connect the GY-DV500’s DV connector and the DV connector of the non-linear editing controller using a DV cable.
For compatible non-linear editing controller, consult with your JVC dealer.

Settings
• To remote control the PC or non-linear editing controller by means of RS-232C, set the VCR Setup Menu item No. 050 REMOTE
SELECT to "RS232C". ☞ See page 68.
• To remote control the GY-DV500’s VCR using the DV connector’s IEEE1394 option, set the VCR Setup Menu item No. 050
REMOTE SELECT to “IEEE1394”. ☞ See page 68.
Note:
• When a cable is connected to the VTR REMOTE connector, the VTR Setup Menu is not displayed in the viewfinder. Make
settings on the VTR Setup Menu while the cable is not connected.
• When a cable is connected to the VTR REMOTE connector, the VCR operation mode will not be displayed correctly on the
Status1 screen in the viewfinder.
n The S.S.F. data stored in the unit's memory can be output from the VTR REMOTE connector.

65

12. SETUP MENU
12-1 VCR Setup Menu
The setup menus for the VCR section can be set while observing the menu in the viewfinder and on the unit's counter display.
The set contents are stored in the memory and retained even after the power is switched OFF.

VCR SETUP MENU CONFIGURATION
The VCR Setup Menu is a two-layer construction.
The VCR Setup Menu consists of seven group menus divided according to functions. When a Group menu is selected, the menu's
Item menu opens. Each Item menu contains one or several items, and the various items can be set individually as required.

VCR Setup Menu
Group Name

Item Menu Contents

000

SERVO/SYSTEM

100
200

VIDEO
AUDIO

300

SYSTEM

400

TIME CODE

Selection of remote control to control the unit
Selection of BACK TALLY lamp lighting pattern
Selection of video input
Selection of low cut for audio input signals
Selection of sampling frequency for audio input signals
Selection of front section audio volume control
Selection of long pause/still duration
Selection of battery type
Selection of S.S.F. (Super Scene Finder) mode
Selection of time code framing mode

500

ON SCREEN

Selection of counter display method (Time code/Date/Time)

HM

HOUR METER

Display of hour meter (accumulated running time of head drum)

Viewfinder display

MENU button

Normal screen
MENU button

000
100
200
300
400
500
HM

: SERVO / SYSTEM
: V I DEO
: AUD I O
: SYSTEM
: T I ME CODE
: ON SCREEN
: HOUR METER

DATA SET button
Counter display

66

Item Menu
(example: AUDIO)

Group Menu

2 4 4 : LOW CUT

SELECT button

OF F

2 4 5 : SAMP L E RATE
4 8K
2 4 6 : FRONT VOLUME

MENU button

ENAB L E

12. SETUP MENU

12-1 VCR Setup Menu (Cont'd)
DISPLAYING AND SETTING VCR SETUP MENUS
CH-1

AUDIO
LEVEL

CH-2
CH-1

PRESET
REGEN

AUDIO SELECT
AUDIO INPUT

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

CH-1

LITHIUM BATT.

MONITOR

FREE
REC

CONTINUE

CH-2

MENU

FRONT
REAR

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

TC GENERATOR

CH-2
AUTO
MANUAL

GROUP

ITEM

HOLD

SHIFT

SELECT

DATA SET

ADVANCE PRESET

MENU
CH-1
FULL AUTO BLACK

GAIN

B

OFF ON
AUTO KNEE

BARS CAM

HML

SAVE STBY

VTR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

PRST A

AUTO IRIS

1.
6.

L
OUTPUT WHT.BA

2. 4. 3. 5.

POWER

NG
ON

OFF

"MENU" indication

1. Engaging the VCR Setup Menu mode.

Viewfinder
000
100
200
300
400
500
HM

Press the MENU button.
• The "MENU" indication in the display section starts
blinking and the VCR Setup Menu appears in the
viewfinder and on the counter display.

: SERVO / SYSTEM
: V I DEO
: AUD I O
: SYSTEM
: T I ME CODE
: ON SCREEN
: HOUR METER

Note:
When a cable is connected to the VTR REMOTE connector,
the VTR Setup Menu is not displayed in the viewfinder.

GROUP menu screen
Counter display

2 4 4 : LOW CUT

2. Selecting the GROUP.
Press the GROUP button.
• Each time the GROUP button is pressed the selected
GROUP number is shown blinking on the viewfinder
screen. The counter display shows the selected group.

3. Open the Item menu of the selected GROUP.
OF F

2 4 5 : SAMP L E RATE
4 8K
2 4 6 : FRONT VOLUME
ENAB L E

Item menu screen

DATA SET

Press the SELECT button.

4. Selecting the Item.
Press the ITEM button.
• Each time the ITEM button is pressed the selected item
number is shown blinking on the viewfinder screen. The
counter display shows the selected item.

5. Changing the setting value of the item.
Press the SELECT button and select the setting value.
n When multiple items should be set, repeat the operations
of steps 4. and 5.
n To set menu items in other groups, press the MENU
button. When the relevant group menu is displayed,
perform the setting.
n When the GROUP button is pressed, the items of the
higher order group menu are displayed.

6. Saving the setting value.
DATA SET display

Press the DATA SET button.
• "DATA SET" appears in the viewfinder and on the counter
display and the setting value is saved in the GY-DV500's
memory. The display returns to the normal screen mode
when data has been saved.
n If the MENU button is pressed without pressing the DATA
SET button, the display returns to the normal screen mode
without the setting value being changed.

67

12. SETUP MENU

12-1 VCR Setup Menu (Cont'd)
VCR SETUP MENU CONTENTS
Setting
Value
Upper row: Viewfinder display
Lower row: Counter display indication
Item

Group

SERVO
/SYSTEM

050: REMOTE SELECT

rnSL

082: BACK TALLY MODE

rtMd

VIDEO

AUDIO

Lc
IE
23

OFF
ON
BLINK
oF
on
bL

126: INPUT SELECT

CAMERA
IEEE1394

vld

cA
IEEE1394

244: LOW CUT

LctF

245: SAMPLING RATE
snPL

246: FRONT VOLUME
ENABLE
FruL

68

LOCAL
IEEE1394
RS232C

OFF
CH1
CH2
CH1 &
CH2
oF
01
02
on
32K
48K
32
48

DISABLE
ENABLE
oF
on

Contents

Factory
Setting

Selection of the method for remote control of the VCR.
LOCAL : Choose this setting when the VCR should
be controlled using the operation buttons
on the GY-DV500 only.
IEEE1394 : Choose this setting when the VCR should
be remote controlled from a DV connector
equipped video component connected to
the DV connector on the rear section of the
GY-DV500.
RS232C : Choose this setting for control by means of
the VCR remote control signal from the VTR
REMOTE connector on the GY-DV500.
* The operation buttons on the GY-DV500 remain
effective even when set to IEEE1394 or RS232C.

LOCAL

Selection of the lighting pattern of the BACK TALLY lamp
on the rear section during recording.
OFF
: The lamp is always off.
ON
: The lamp lights during recording. It remains
off until the VTR trigger button is pressed
to start the recording.
BLINK
: The lamp lights during recording. It blinks
when the VTR trigger button is pressed to
start the recording.

BLINK

Selection of the input video signal.
Settings cannot be changed during recording.
CAMERA : Camera image is input.
IEEE1394 : The image from the DV connector equipped
video component connected to the DV
connector on the rear section is input.

CAMERA

To select whether or not the low frequencies of the audio
signal from the audio input connectors are cut. Set to
ON to reduce the wind noise of the microphone.
OFF
: The CH1 and CH2 low frequencies are not cut.
CH1
: Only the low frequencies of the audio signal
input to the CH1 channel are cut.
CH2
: Only the low frequencies of the audio signal
input to the CH2 channel are cut.
CH1& CH2 :The low frequencies are cut for both CH1
and CH2.

OFF

To select the sampling rate for digital PCM audio recording.
32K
: Digital recording occurs with 12-bit, 32 kHz
sampling
48K
: Digital recording occurs with 16-bit 48 kHz
sampling.
* The DV format offers recording tracks for up to 4
channel when recording using 12-bit, 32 kHz
sampling. The GY-DV500 records two of these tracks.
The GY-DV500 does not allow after-recording.

48K

To select whether or not the front section recording level
control should be operative. The front section recording
level control only affects the audio signal recorded on CH1.
DISABLE : Use of the front section recording level
control is disabled.
ENABLE : Use of the front section recording level
control is enabled.
* The CH-1 recording level control on the side section
works regardless of the setting.

ENABLE

12. SETUP MENU

12-1 VCR Setup Menu (Cont'd)
Setting
Value
Upper row: Viewfinder display
Lower row: Counter display indication
Item

Group

SYSTEM

TIME CODE

307: LONG PAUSE
TIME

3MIN
30MIN

LGPt

03
30

396: BATTERY TYPE

12V
13.2V
14.4V

bAtt

12
13
14

398: SSF MODE

OFF
CUE MODE
MARK MODE

SSF

oF
cU
nr

416: NON DROP/DROP

Selection of the time code generator's framing mode as
DROP
NON DROP either drop or non-drop mode.
DROP : The internal time code generator runs in drop
mode. Choose this setting when emphasizing
dF
the recorded time.
nF
NON DROP: The internal time code generator runs in
non drop mode. Choose this setting when
emphasizing the frame number.

tcG

ON
SCREEN

Contents

516: DISPLAY SELECT

TC
CLOCK

dSP

tc
cL

To select the time (minutes) before the save mode (drum
head rotation stopped) is engaged when the recordpause, still or stop condition continues.
3MIN : 3 minutes
30MIN : 30 minutes
* When used in a cold environment, the setting will be
3 minutes regardless of the setting.
To be set in accordance with the used battery back type.
12V
: Choose this setting when using 12V battery
(12V DC Flat Shape type).
13.2V : Choose this setting when using 13.2V battery
(Anton-Bauer Trimpack 13, Propack 13,
Magnum 13, Compack 13).
14.4V : Choose this setting when using 14.4V battery
(Anton-Bauer Trimpack 14, Propack 14,
Magnum 14, Compack 14).
Note:
• If this setting is neglected, the unit’s display of
remaining of battery power and generation of
battery alarm will not work correctly.
• This setting is valid when battery pack is used. It
is invalid when a DC power supply is used.
Selection of the S.S.F. (Super Scene Finder) mode.
S.S.F. function:While recording, the time code data of a
desired recorded scene is stored in the unit's memory
when the TAKE button on the front section is pressed.
Settings cannot be changed during recording or SAVE
mode.
OFF
: S.S.F. function is not available.
CUE MODE : Selects the CUE mode.
When the TAKE button is pressed, the
time code data of the scene recorded
at that point is stored in the memory.
MARK MODE : Selects the MARK mode.
When the TAKE button is pressed the
first time, the time code of this point is
stored as start point of the scene. When
the TAKE button is pressed the second
time, the time code of this point is stored
as ending point of the scene.
For details on the S.S.F. function, see page 60.
• When the VCR Setup Menu item No. 398 S.S.F. MODE
is set to CUE or MARK, the time code generator’s
running method is internally set to the REGEN mode.

Selection of the appearance of the counter display when
the COUNTER switch is set to “TC” or “UB”.
TC
: The time code is displayed.
CLOCK: The date/time is displayed.

Factory
Setting
30MIN

12V

OFF

DROP

TC

69

12. SETUP MENU

12-2 Camera Menu Screen Flow
Camera Menu Screen Flow
As illustrated below, the Camera Menu is a menu screen comprising several layers. The first layer of the CAMERA MENU screen is
for choosing and setting the menus required in accordance with functions or purposes.
The unit also allows the contents of menu settings to be stored in three files (SCENE FILE A, B, OFF).
• SCENE FILE A, B ........... By performing the FILE STORE operation on the FILE MANAGE screen, the contents of menu
settings can be stored and retained in the unit. However, the SET UP menu contents are stored
even if the FILE STORE operation is not performed.
Use SCENE FILE A or B to store and retain the contents of menu settings that remain more or less
fixed.
• SCENE FILE OFF ........... Whenever you want to change the menu settings, use this SCENE FILE.
The menu setting contents are stored in the unit even if the FILE STORE operation is not performed.
When shooting, select the file with the menu settings to be used from among the three SCENE FILE files on the CAMERA MENU
screen.
- - - VF D I SP L AY - - SCENE F I L E A
F . NO D I SP L AY
: ON
AUD I O D I SP L AY
: ON
: OFF
SAFETY ZONE
REC T I ME
: REMA I N
ZEBRA
: 7 0 - 8 0%
PAGE BACK

- - - OPERAT I ON - - SCENE F I L E A
SHUT TER
: STEP
: NONE
FAW
: 0 dB
GA I N L
GA I N M
: 9dB
GA I N H
: 1 8dB
SMOOTH TRANS
: OFF
PAGE BACK

- - - CAMERA MENU - - SCENE F I L E
VF D I SP L AY MENU . .
OPERAT I ON MENU . .
PROCESS MENU . .
F I L E MANAGE . .
SETUP MENU . .
EX I T

:A

- - - PROCESS - - SCENE F I L E A
MASTER B L ACK
: NORMA L
: NORMA L
DETA I L
: NORMA L
DT L . V / H BA L
DT L . FREQUENCY
: M I DDL E
SK I N DT L DETECT
: OF F
V RESOLUT I ON
: NORMA L
ADVANCED PROCESS
PAGE BACK

- - - ADVANCED PROC ES S - - SCENE F I L E A
COLOR MATR I X
: ON
GAMMA
: NORMA L
SK I N COLOR ADJUST . .
PAGE BACK

- - - F I L E MANAGE - - SCENE F I L E A
STORE F I L E
:A
STORE
: OFF
RESET F I L E
RESET
PAGE BACK
STORE OK ?

Normal screen

- - - SETUP - - H PHASE
SC PHASE
CAM M I C + 4 8 V
PAGE BACK

- - SK I N COLOR AD J U ST

--

: 128
: 128
: OFF

ERORR
EXECUTE
SK I N COL OR DET .
SK I N COL OR RANGE
: NORMA L
PAGE BACK

70

12. SETUP MENU

12-3 How to Select from the Camera Menu
1. Press the STATUS button for 1 second to display the
CAMERA MENU screen in the viewfinder.

2. Choose the file with the camera menu settings to be used.
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

HML

SAVE STBY

GAIN

OFF
BARS CAM
AUTO KNEE
ON

VTR

AUDIO CH-2
LEVEL

LOLUX

PRST A B

AUTO IRIS

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

STATUS button

2. 3. 4. 5. 6. 8.

(SCENE FILE A, B or OFF)
1 Turn the SHUTTER dial up or down to align the cursor
with SCENE FILE, and then press the SHUTTER dial
in the direction of the arrow.
• The area with the setting value starts blinking, and the
value can now be changed.
2 Turn the SHUTTER dial up or down to select the setting
value. (A, B or OFF)
3 Press the SHUTTER dial in the direction of the arrow.
• The setting value stops blinking but remains lit.

3. Turn the SHUTTER dial up or down to align the cursor with

SHUTTER dial

SHUTTER

the menu item to be set, and then press the SHUTTER dial
in the direction of the arrow.
• The selected menu screen appears in the viewfinder.

4. Choose the menu item from the menu screen.
MENU

CURSOR Item

Setting value

- - - CAMERA MENU - - SCENE F I L E
VF D I SP L AY MENU
OPERAT I ON MENU
PROCESS MENU
F I L E STORE
SETUP MENU
EX I T

:A

Turn the SHUTTER dial up or down to align the cursor with
the menu item to be set, and then press the SHUTTER dial
in the direction of the arrow.
• The area with the setting value starts blinking, and the
value can now be changed.

5. Change the setting value.
Turn the SHUTTER dial up or down to change the setting
value, and then press the SHUTTER dial in the direction of
the arrow.
• The setting value stops blinking but remains lit.
n To change multiple items, repeat steps 4. and 5. above.

6. Return to the CAMERA MENU screen.

CAMERA MENU screen

Turn the SHUTTER dial up or down to align the cursor with
the PAGE BACK item, and then press the SHUTTER dial in
the direction of the arrow.
n To change the settings of other menu screens, perform
the operations described in steps 3. to 6. above.

7. If SCENE FILE A or B is selected, choose the FILE
Item

Setting value
- - - VF D I SP L AY - - -

SCENE F I L E A
F . NO D I SP L AY
: ON
AUD I O D I SP L AY
: ON
: OFF
SAFE TY ZONE
REC T I ME
: REMA I N
ZEBRA
: 7 0 - 8 0%
PAGE BACK

MANAGE item from the CAMERA MENU screen and
perform the operations for storing a file.
☞ See "FILE MANAGE Screen" on page 76.
* It is not necessary to perform the file storage operations
for changes made to the SETUP MENU.

8. Complete the CAMERA MENU setting.
Turn the SHUTTER dial up or down to align the cursor with
the EXIT item on the CAMERA MENU screen, and then
press the SHUTTER dial in the direction of the arrow.
• The normal screen returns in the viewfinder.

VF DISPLAY MENU screen

71

12. SETUP MENU

12-4 VF Display Screen
Item

Function, Operation

Variation Range Initial Setting

F NO.
DISPLAY

Selects whether or not the F-number of the lens iris is displayed on the
Status 1 screen.
ON ........................ F-number is displayed.
OFF ....................... F-number is not displayed.

ON
OFF

ON

AUDIO
DISPLAY

Selects whether or not the audio indicator is displayed on the Status 1
screen.
ON ........................ Audio indicator is displayed.
OFF ....................... Audio indicator is not displayed.

ON
OFF

ON

SAFETY ZONE

Selects the safety zone setting.
☞ See "Safety Zone" on page 29.

OFF
ZONE 1
ZONE 2
ZONE 3

OFF

REC TIME

Sets whether the remaining tape recording time or TIME CODE is displayed
on the Status 1 screen.
TIME CODE .......... TIME CODE is displayed.
* The time code is displayed even if the VCR Setup
Menu item No. 516 DISPLAY SELECT is set to
“CLOCK”.
REMAIN ................ Remaining time is displayed.

TIME CODE
REMAIN

REMAIN

ZEBRA

Switches the luminance level of the subject sections where the zebra
pattern is displayed.
70-80% ................. Zebra pattern is displayed in sections with luminance
levels between 70% and 80%.
85-95% ................. Zebra pattern is displayed in sections with luminance
levels between 85% and 90%.
OVER 95% ............ Zebra pattern is displayed in sections with luminance
levels over 95%.
OVER 100% .......... Zebra pattern is displayed in sections with luminance
levels over 100%.

70-80%
85-95%
OVER95%
OVER100%

70-80%

PAGE BACK

The CAMERA MENU returns when the SHUTTER dial is pressed with
the cursor at this position.

–

–

72

12. SETUP MENU

12-5 OPERATION Screen
Item

Function, Operation

Variation Range Initial Setting

SHUTTER

The SHUTTER button on the right side section is used to select STEP for
fixed shutter speed or V.SCAN variable scanning rate for shooting computer
monitor screens.
STEP .............. Enables setting of different fixed shutter speeds. [1/100,
1/250, 1/500, 1/1000, 1/2000]
VARIABLE ....... Selected when shooting computer monitor screens, etc.
[Variable range: 60.1 to 2084.6 Hz]

STEP
VARIABLE

STEP

FAW

Selects the W.BAL switch (@ on page 13) position to which the FAW (FullTime Auto White Balance Adjustment) function is to be assigned.
NONE ............. FAW function is not used.
A ..................... FAW is assigned to the A position.
B ..................... FAW is assigned to the B position.
PRESET ......... FAW is assigned to the PRESET position.

NONE
A
B
PRESET

NONE

GAIN L
GAIN M
GAIN H

Selects the gain value in each position of the GAIN switch (9 on page
13).

–3dB
0dB
6dB
9dB
12dB
18dB
ALC

L: 0dB
M: 9dB
H: 18dB

SMOOTH
TRANS

Smoothens the transition when the GAIN switch (9 on page 13), or
WHT.BAL switch (@ ) is switched over and achieves gradual change in
place of sudden change.
However, the smooth transition function does not function when switching
the GAIN switch set in ALC, FAS button and the LOLUX button.
ON .................. Activates the smooth transition function.
OFF ................. Deactivates the smooth transition function.

ON
OFF

OFF

PAGE BACK

The CAMERA MENU returns when the SHUTTER dial is pressed with
the cursor at this position.

–

–

73

12. SETUP MENU

12-6 PROCESS Screen
Item

Function, Operation

Variation Range Initial Setting

MASTER
BLACK

Adjusts the pedestal level (master black), which is the reference of black.
• To increase the pedestal level ...... Increase the number. (UP)
• To decrease the pedestal level .... Decrease the number. (DOWN)

MAX (100)
99 201
gradations
to
NORMAL (0)
to
-99
MIN (-100)

NORMAL

DETAIL

Adjusts the detail enhancement level.
• To sharpen details ....................... Increase the number. (UP)
• To soften details ........................... Decrease the number. (DOWN)

MAX (9)
8
16
gradations
to
NORMAL (0)
to
-5
MIN (-6)

NORMAL

DTL. V/H
BAL

Sets the direction, horizontal (H) or vertical (V), in which stronger detail
enhancement is applied.
To strengthen the H enhancement ... .. Increase the number (UP).
To strengthen the V enhancement ... .. Decrease the number (DOWN).

H-MAX (4)
3
9
gradations
to
NORMAL (0)
to
-3
H-MIN (-4)

NORMAL

Note:
While the LOLUX function is operating, the setting value is fixed at
NORMAL and “FIX” is displayed.
DTL.
FREQUENCY

Varies the detail enhancement level by changing the detail enhancement
frequency. Set in accordance with the subject
HIGH ............. Applies strong detail enhancement.
Used to shoot subjects with fine patterns.
MIDDLE ........ Applies medium detail enhancement.
LOW .............. Applies weak detail enhancement.
Used to shoot subjects with large patterns.
Note:
While the LOLUX function is operating, the setting value is fixed at
MIDDLE and “FIX” is displayed.

HIGH
MIDDLE
LOW

MIDDLE

SKIN DTL
DETECT

Sets the Skin Detail function to ON or OFF.
ON ................ Skin Detail function activated.
OFF ............... Skin Detail function not activated.
☞ See "Using the Skin Detail Function" on page 84.

ON
OFF

OFF

V.
RESOLUTION

Increases the vertical resolution.
• NORMAL .... Vertical resolution 380 lines.
• V.MAX ......... Vertical resolution 450 lines

NORMAL
V.MAX

NORMAL

–

–

Note:
The sensitivity is degraded and the bright sections may be colored
depending on the subject.
ADVANCED
PROCESS

ADVANCED PROCESS
Displays the ADVANCED PROCESS Screen.
☞ See "ADVANCED PROCESS Screen" on page 75.

PAGE BACK

The CAMERA MENU returns when the SHUTTER dial is pressed with
the cursor at this position.

74

12. SETUP MENU

12-7 ADVANCED PROCESS Screen
Item
COLOR
MATRIX

Function, Operation
Sets the color matrix
OFF ...... Deactivates the color matrix function
ON ....... The color reproducibility is enhanced, but noise increases.

Variation Range Initial Setting
ON
OFF

ON

MAX (8)
7
17
gradations
to
NORMAL (0)
to
-7
MIN (-8)

NORMAL

–

–

CAUTION:
During the LOLUX operation, COLOR MATRIX is fixed to the OFF
setting and "FIX" is displayed.

GAMMA

Correction of the gamma curve to decide the reproducibility of black color.
• To enhance the black color reproducibility. However, halftones will be
lost for white section
............... Increase the number
• When reproducibility of the black color is not so important
............... Decrease the number
CAUTION:
• During LOLUX operation, "FIX" is displayed because GAMMA is fixed
at the MIN value.

SKIN COLOR
ADJUST

Pressing the SHUTTER dial once when the cursor is at this position
switches the screen to display the SKIN COLOR ADJUST screen.

PAGE BACK

The PROCESS MENU returns when the SHUTTER dial is pressed with
the cursor at this position.

12-8 SKIN COLOR ADJUST Screen
Item

Function, Operation

Variation Range Initial Setting

SKIN COLOR
DETECT

Sets whether it is possible to change the color used by the Skin Detail
function.
EXECUTE ...... Choose this setting to allow detection of the color used by
the Skin Detail function.
STOP ............. Choose this setting to stop detection of the color used by
the Skin Detail function.
☞ See "Using the Skin Detail Function" on page 84.

STOP
EXECUTE

STOP

SKIN COLOR
RANGE

The setting of this item can only be changed when the SKIN COLOR
DETECT item is set to EXECUTE.
This setting is for adjusting the skin color range where Skin Detail functions.
(When this item is selected, the area where the Skin Detail function is
applicable is indicated by zebra patterns on the screen.)
While viewing the zebra pattern range, perform the adjustment.
Increasing the range ........ Increase the number
Increasing the range . ...... Decrease the number

WIDE
+19
(33 gradations)
to
NORMAL
to
-11
NARROW

NORMAL

PAGE BACK

The ADVANCED PROCESS MENU returns when the SHUTTER dial is
pressed with the cursor at this position.

–

–

75

12. SETUP MENU

12-9 FILE MANAGE Screen
The unit has three files that can be used for storing camera menus. The FILE MANAGE screen is for performing the operations for
saving the set CAMERA MENU.
• When menu settings are made using SCENE FILE A or B, the contents of the settings will be invalid if the storage operations
are not performed on this screen. However, the SETUP MENU settings will be valid even if the storage operations are not
performed.
• When menu settings are made using SCENE FILE OFF, the contents are stored in the unit at the time settings are changed
on each menu screen even if the storage operations are not performed.

Storage Operation

1. Press the STATUS button for about 1 second to display the
CAMERA MENU screen.

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

2. Turn the SHUTTER dial to align the cursor with the FILE
MANAGE item, and then press the SHUTTER dial in the
direction of the arrow.
• The FILE MANAGE screen appears in the viewfinder.

MONITOR

MENU
CH-1
FULL AUTO BLACK

L
OUTPUT WHT.BA

ON

SHUTTER dial

3. Choose the file to save in (A or B).

POWER

NG

2. 3. 4. 5.

PRST A B

HML

GAIN

BARS CAM

SAVE STBY

VTR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

OFF

1 Turn the SHUTTER dial to select the STORE FILE item,
and then press the SHUTTER dial in the direction of
the arrow.
2 Turn the SHUTTER dial to select the file to save in (A or
B), and then press the SHUTTER dial in the direction of
the arrow.

1. STATUS button

SHUTTER

4. Save the menu settings.
Turn the SHUTTER dial to align the cursor with the STORE
item, and then press the SHUTTER dial in the direction of
the arrow.
• The “STORE OK?” message appears in the lower section
of the centre of the screen.
When the SHUTTER dial is pressed in the direction of
the arrow once more, the menu settings are stored in
the selected STORE FILE.

MENU

- - - CAMERA MENU - - -

Cursor

SCENE F I L E
VF D I SP L AY MENU
OPERAT I ON MENU
PROCESS MENU
F I L E MANAGE
SETUP MENU
EX I T

:A

5. Close the FILE MANAGE screen
Turn the SHUTTER dial to align the cursor with PAGE BACK,
and then press the SHUTTER dial in the direction of the
arrow.
• The CAMERA MENU screen returns in the viewfinder.
Memo:
•

CAMERA MENU screen
- - - F I L E MANAGE - - -

Cursor

SCENE F I L E A
STORE F I L E
:A
STORE
: OFF
RESET F I L E
RESET
PAGE BACK
STORE OK ?

FILE MANAGE screen

•

n

When changing the menu settings in SCENE FILE A
and saving in STORE FILE B:
SCENE FILE B: The contents become the menu
contents of the changed settings.
SCENE FILE A: The contents become the menu
contents valid before the settings were changed.
When changing the menu settings in SCENE FILE OFF
and saving in STORE FILE B:
SCENE FILE B: The contents become the menu
contents of the changed settings.
SCENE FILE OFF: The contents become the menu
contents of the changed settings.
Resetting the menu settings to the initial settings is also
done using the FILE MANAGE screen.
☞ See "Resetting the Camera Menu Settings" on page 78.

76

12. SETUP MENU

12-10 SETUP Screen
Item

Function, Operation

Variation Range Initial Setting

H PHASE

For adjusting the horizontal phase of the unit in relation to the signal
(external sync signal) input through the SYNC IN connector on the left
side of the unit.
Delaying the horizontal phase of the unit in relation to the external sync
signal .
................... Increase the number
Speeding up the horizontal phase of the unit in relation to the external
sync signal .
................... Decrease the number
* Adjustment is not possible if the external sync signal is not input. Possible
values are indicated by ***.

0
to
256

SC PHASE

For adjusting the sub-carrier (SC) of the unit in relation to the signal
(external sync signal) input through the SYNC IN connector on the left
side of the unit.
Rotating the sub-carrier clockwise in relation to the external sync signal
................... Increase the number
Rotating the sub-carrier anticlockwise in relation to the external sync signal
................... Decrease the number
* Adjustment is not possible if the external sync signal is not input. Possible
values are indicated by ***.
The phase will change when the power is turned on/off. The SC phase
must be adjusted each time the power is turned on.

0
to
256

CAM MIC +48V

To set whether or not 48V voltage should be applied to the MIC IN connector
on the front section.
ON ............. 48V applied.
OFF ............ 48V not applied.

ON
OFF

ON

PAGE BACK

The CAMERA MENU returns when the SHUTTER dial is pressed with
the cursor at this position.

–

–

128

128

77

12. SETUP MENU

12-11 Resetting of Camera Menu Setting Values
Using the FILE MANAGE screen, the CAMERA MENU settings can be reset to the initial setting values. On the FILE MANAGE
screen, select the file of the CAMERA MENU to be reset, and then perform the resetting operation.

Reset Operation

1. Press the STATUS button for about 1 second to display the
CAMERA MENU screen.
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

GAIN

L
OUTPUT WHT.BA

POWER

NG
ON

2. 3. 4. 5.
SHUTTER dial

3. Choose the file of the CAMERA MENU to be reset (A, B,

PRST A B

HML

BARS CAM

SAVE STBY

VTR

AUDIO CH-2
LEVEL

LOLUX

OFF

1. STATUS button

SHUTTER

Turn the SHUTTER dial to align the cursor with the RESET
item, and then press the SHUTTER dial in the direction of
the arrow.
• The “RESET OK?” message message appears in the
lower section of the centre of the screen.
When the SHUTTER dial is pressed in the direction of the
arrow once more, the CAMERA MENU settings of the
selected file are reset to the initial settings.

- - - CAMERA MENU - - SCENE F I L E
VF D I SP L AY MENU
OPERAT I ON MENU
PROCESS MENU
F I L E MANAGE
SETUP MENU
EX I T

:A

CAMERA MENU screen

- - - F I L E MANAGE - - -

Cursor

SCENE F I L E A
STORE F I L E
:A
STORE
: OFF
RESET F I L E
RESET
PAGE BACK
RESET OK ?

FILE MANAGE screen

78

OFF or ALL)
• If ALL is selected, all the CAMERA MENU files will be
reset.
1 Turn the SHUTTER dial to align the cursor with the
RESET FILE item, and then press the SHUTTER dial in
the direction of the arrow.
2 Turn the SHUTTER dial to select the file to be reset,
and then press the SHUTTER dial in the direction of the
arrow.

4. Reset the camera menu settings.

MENU

Cursor

MANAGE item, and then press the SHUTTER dial in the
direction of the arrow.
• The FILE MANAGE screen appears in the viewfinder.

STRETCH
NORMAL
COMPRESS

OFF ON
AUTO KNEE

AUTO IRIS

2. Turn the SHUTTER dial to align the cursor with the FILE

5. Close the FILE MANAGE screen
Turn the SHUTTER dial to align the cursor with PAGE BACK,
and then press the SHUTTER dial in the direction of the
arrow.
• The CAMERA MENU screen returns in the viewfinder.

13. FEATURES OF THE CAMERA SECTION
13-1 Full-Time Auto White Balance (FAW)
The FAW function adjusts the white balance
value automatically as the lighting condition
changes.

- - - OPERAT I ON - - SCENE F I L E A
SHUT TER
: STEP
: NONE
FAW
: 0 dB
GA I N L
GA I N M
: 9dB
GA I N H
: 1 8dB
SMOOTH TRANS
: OFF
PAGE BACK

This mode is convenient when you have no time to adjust the
white balance or when the camera is moved frequently in and
out of places under different lighting conditions.

Setting procedure
The FAW function can be activated with item "FAW" on the
OPERATION Menu.
This item allows allocation of the FAW function to the A, B or
PRST position of the WHT.BAL selector switch.
☞ See "OPERATION Screen" on page 73.
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1
FULL AUTO BLACK

B

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

FULL AUTO BLACK
BACK L
NORMAL
SPOT L

GAIN

B
PRST A

BARS CAM

HML

Y
SAVE STB

VTR

LOLUX
STRETCH
NORMAL
COMPRESS

OFF ONE
AUTO KNE

AUTO IRIS

PRST A

BARS CAM

HML

SAVE STBY

GAIN

VTR

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ON
AUTO KNEE

AUTO IRIS

CAUTION:
The FAW (Full-time Auto White balance) function cannot
provide optimum white balance with a subject outside the
FAW adjustment range, for example when it contains only
a single color or not enough white color.

T.BAL
OUTPUT WH

POWER

NG
ON

OFF

WHT.BAL selector switch

79

13. FEATURES OF THE CAMERA SECTION

13-2 IRIS (Brightness) Adjustment
ADJUSTMENT OF LENS IRIS

The lens iris can be adjusted using any of the
following three methods.
• Automatic adjustment
Set the iris mode switch to "A" (Auto).
The iris is adjusted automatically according to the brightness
of the object.

Iris ring

• Manual adjustment
Set the iris mode switch to "M" (Manual).
The iris can be adjusted manually by rotating the iris ring.

RET

• Temporary auto iris adjustment
During manual iris adjustment, the auto iris adjustment mode
is activated only while this button is held depressed.

M
A

W

T

n Changing the auto iris adjustment setup
Temporary auto iris
button
Iris mode switch

Under special lighting conditions such as backlight, it is often
appropriate to change the value set by the auto iris
adjustment.
This can be done by the following methods.
• Setting the AUTO IRIS LEVEL switch of the camera
☞ See "SWITCH FUNCTIONS" on page 83.

ZEBRA PATTERN DISPLAY DURING MANUAL ADJUSTMENT

OFF
ON

ZEBRA
SKIN
AREA

AUTO
WHITE
ACCU
FOCUS

VTR AUDIO
LEVEL CH-1

ZEBRA switch

TAKE

By setting the ZEBRA switch to ON, oblique stripes (zebra
pattern) can be displayed in the sections with a luminance level
of 70% to 80% or sections with levels over 100% in the
viewfinder.
The zebra pattern can be used as a reference for manual iris
adjustment.
When adjusting the iris manually, adjust it so that the zebra
patterns are displayed in the section that you want to stress in
the subject.
• The initial setting is 70 to 80%. However, using the "ZEBRA"
setting on the VF DISPLAY MENU, zebra patterns can be
displayed in the sections with a luminance level of 85 to 95%,
over 95% and over 100%.
☞ See "VF DISPLAY MENU Screen" on page 72.

80

13. FEATURES OF THE CAMERA SECTION

13-3 Shooting the Screen Image on a Computer Monitor
n Outline
Band

Video monitor

The following operation allows the alignment of the shutter
speed of the camera with the variable scanning rate of a
computer monitor or display.
When a computer monitor screen or display is shot with the
camera, a bright horizontal line indicating excessive exposure
is displayed in cases when the scanning rate of the monitor
is faster than the shutter speed of the camera. A dark
horizontal line indicating insufficient exposure is displayed in
cases when the monitor's scanning rate is slower than the
camera's shutter speed.
The scanning frequency of a monitor varies due to various
reasons during the computer operation. Adjust the scanning
rate to obtain a stable image while observing the image in
the viewfinder.

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

n Variable Scan [V.SCAN]

MENU
CH-1
FULL AUTO BLACK
STRETCH
NORMAL
COMPRESS

PRST A B

HML

SAVE STBY

GAIN

BARS CAM

BACK L
NORMAL
SPOT L

VTR

AUDIO CH-2
LEVEL

LOLUX

OFF ON
AUTO KNEE

AUTO IRIS

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

SHUTTER dial

- - - OPERAT I ON - - SCENE F I L E A
SHUT TER
: VAR I ABL E
: NONE
FAW
: 0 dB
GA I N L
GA I N M
: 9dB
GA I N H
: 1 8dB
SMOOTH TRANS
: OFF
PAGE BACK

• Basic operation
Set the SHUTTER item on the OPERATION MENU screen
to VARIABLE. Then move the SHUTTER knob upwards or
downwards to change the shutter speed.
(The speed is displayed on the viewfinder screen.)
• Compatible frequencies
The variable scan function is compatible with scanning
frequencies in the following range.
60.1 to 2084.6 Hz
CAUTION:
This function is not compatible with slow-speed computer
monitors with a vertical scanning speed of 50 Hz.

OPERATION MENU screen

81

13. FEATURES OF THE CAMERA SECTION

13-4 Gain (Sensitivity) Adjustment
The gain should be switched when the brightness is insufficient due to poor lighting conditions.

GAIN SWITCHING
This switch allows the gain to be boosted when the illumination
of the subject is insufficient.

GAIN switch

FULL AUTO BLACK

Factory-Set Gain

L

0dB

M

9dB

H

18dB

STRETCH
NORMAL
COMPRESS

BARS CAM

HML

Y
SAVE STB

OFF ONE
AUTO KNE

BACK L
NORMAL
SPOT L

T.BAL
OUTPUT WH

GAIN

VTR

Switch Position
LOLUX

B
PRST A

AUTO IRIS

When the GAIN switch is switched, the newly set gain is
displayed for about 2 seconds on the Status 0 or Status 1 screen
in the viewfinder.
Set it to L (0 dB) in normal use.

POWER

NG
ON

OFF

n The gain set for each of the switch positions can be changed
with "GAIN" on the OPERATION MENU screen.
n It is also possible to use the ALC function that varies the gain
automatically.
☞ See page 73 for details.
CAUTION:
When gain is set to "ALC", gain is boosted automatically
as the illumination becomes darker. However, noise will
increase a little because the screen becomes brighter as
the ALC (Auto Level Control) function boosts the gain more
than in the case of manual adjustment.

n To make the gain transition smoother, set “SMOOTH TRANS”
on the OPERATION MENU to “ON”.
☞ See page 73.
However, note that the SMOOTH TRANS function is not
available if gain is set to ALC.

GAIN BOOST UNDER LOLUX CONDITION
LOLUX on/off button
FULL AUTO BLACK

B
PRST A

BARS CAM

HML

Y
SAVE STB

T.BAL
OUTPUT WH

GAIN

VTR

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

OFF ONE
AUTO KNE

AUTO IRIS

The LOLUX button is used when the illumination is still
insufficient after compensating with the GAIN switch.
Press the button to enter the LOLUX mode in which the gain is
boosted by about 33 dB.
"LOLUX ON" is displayed for about 2 seconds on the Status 0
or Status 1 mode screen in the viewfinder.
Pressing the button again cancels the LOLUX mode.
"LOLUX OFF" is displayed for about 2 seconds.

POWER

NG
ON

n When the LOLUX function is in use, the image definition on
the screen will degrade to increase residual images, but this
is not a malfunction.

OFF

[Relationship between gain, iris and shutter]
0.7 Lx

8 Lx

32 Lx

2000 Lx

4200 Lx

18000 Lx

FULL AUTO SHOOTING
33 dB

12dB
LOLUX

0 dB

ALC
F1.4

82

1/60
AUTOMATIC IRIS

1/240
EEI

F11

F16

13. FEATURES OF THE CAMERA SECTION

13-5 Switch Setup According to Illumination and Subject
Various switch settings are performed to accommodate the conditions of the illumination and the subject when shooting.

SWITCH FUNCTIONS
1AUTO IRIS LEVEL switch

AUTO IRIS LEVEL
switch
AUTO IRIS

This switch allows the reference value for the auto iris
adjustment to be changed according to the lighting condition.
BACK. L : When the subject is in backlit conditions.
Sets the Auto Iris reference value to a value that
is about 1 step wider than the standard setting.
NORMAL: Normal lighting condition.
SPOT. L : When the subject is under a spotlight.
Sets the Auto Iris reference value to a value that
is about 1 step narrower than the standard setting.

BLACK stretch/black
compress setting switch

FULL AUTO BLACK

LOLUX

OFF ONE
AUTO KNE

BARS CAM

HML

Y
SAVE STB

T.BAL
OUTPUT WH

GAIN

VTR

B
PRST A

STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

2BLACK stretch/black compress switch
This switch makes the image easier to see by varying the
black gain.
BLACK STRETCH : Boosts the gain of black areas to
improve the reproducibility of black.
NORMAL
: Normal black gain.
BLACK COMPRESS : Attenuates the gain of black areas
to make the image sharper.

POWER

NG
ON

OFF

FULL AUTO SHOOTING (FAS) FUNCTION

FULL AUTO
indicator

FULL AUTO\
shooting button
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

GAIN

B
PRST A

BARS CAM

HML

Y
SAVE STB

VTR

LOLUX
STRETCH
NORMAL
COMPRESS

OFF ONE
AUTO KNE

AUTO IRIS

T.BAL
OUTPUT WH

POWER

NG
ON

The FAS function provides a wide range of compatibility with
shooting conditions that varies as you move between indoors
and outdoors or between bright and dark locations. It eliminates
the need to change the switch and filter positions every time
you move.
The FAS function provides an integrated control of the ALC
(Automatic Level Control), Auto iris and FAW (Full-time Auto
White balance) functions.

OFF

Operation

1. Simply press the FULL AUTO button to enter the FAS mode,
in which the FULL AUTO indicator lights and "FAS" is
displayed to the right in the viewfinder.

2. Pressing the FULL AUTO button again cancels the FAS
mode and turns the FULL AUTO indicator off.

n Automatic Setting Contents
• If you have been displaying the color bars, the screen is
switched automatically to the camera image.
• The auto iris adjustment mode is entered even if the iris mode
switch of the lens is set to manual.
CAUTION:
• When the power is turned on while the camera is in the
FAS mode, it takes about 10 seconds before the
automatic adjustment of FAS is completed.
• In the FAS mode, the audio recording level is not set
automatically to the AUTO mode.
To select the AUTO mode, set the AUTO/MANUAL switch
of the VCR section to AUTO.

• The GAIN switch and WHT.BAL switch settings are defeated
in the FAS mode.
• The LOLUX button setting is active even in the FAS mode.
However, the ALC and EEI are defeated in the LOLUX mode,
in which only the auto iris adjustment and FAW are used.
• All of the previous setting contents are recalled when the
FAS mode is cancelled.
• The SMOOTH TRANS function is defeated during switch to
the FAS function.

83

13. FEATURES OF THE CAMERA SECTION

13-6 How to Use Skin Detail
The contour emphasis in the skin color areas of the video signal can be controlled and made to appear gentle and smooth.

n Setting the Color and Range of the Skin Detail
Function
OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1 AUDIO CH-2

1. Press the STATUS button for about 1 second to display the
CAMERA MENU screen.

LEVEL
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

GAIN

B

2. Turn the SHUTTER dial downward to align the cursor (>)

OUTPUT WHT.BAL

POWER

NG
ON

2. ~ 8.

PRST A

HML

BARS CAM

SAVE STBY

VTR

LOLUX
STRETCH
NORMAL
COMPRESS

OFF ON
AUTO KNEE

AUTO IRIS

OFF

1. STATUS button

3. Turn the SHUTTER dial downward to align the cursor (>)

SHUTTER dial

with the ADVANCED PROCESS item. Then press the
SHUTTER dial in the direction of the arrow to display the
ADVANCED PROCESS screen.

SHUTTER

MENU

4. Turn the SHUTTER dial downward to align the cursor (>)

- - - CAMERA MENU - - -

Cursor

with the PROCESS item. Then press the SHUTTER dial in
the direction of the arrow to display the PROCESS screen.

SCENE F I L E
VF D I SP L AY MENU
OPERAT I ON MENU
PROCESS MENU
F I L E MANAGE
SETUP MENU
EX I T

:A

with the SKIN COLOR ADJUST item. Then press the
SHUTTER dial in the direction of the arrow to display the
SKIN COLOR ADJUST screen.
• The frame shown on the screen indicates the detection
area of the skin detail function.

5. When the cursor (>) is aligned with the SKIN COLOR DET.
item, the SHUTTER dial is pressed in the direction of the
arrow and EXECUTE selected, the skin color detection
mode is activated.

- - - PROCESS - - SCENE F I L E A
MASTER B L ACK
: NORMA L
: NORMA L
DETA I L
: NORMA L
DT L . V / H BA L
DT L . FREQUENCY
: LOW
SK I N COLOR DETECT : OF F
V RESOLUT I ON
: NORMA L
ADVANCED PROCESS
PAGE BACK

PROCESS screen
- - - ADVANCED PROC ES S - - SCENE F I L E A
COLOR MATR I X
: ON
GAMMA
: NORMA L
SK I N COLOR A D J US T
PAGE BACK

ADVANCED PROCESS screen
- - SK I N CO LOR AD J U ST

--

Detection
area
ERORR
: EXECUTE
SK I N COL OR DET .
SK I N COL OR RANGE
: NORMA L
PAGE BACK

SKIN COLOR ADJUST screen

6. Shoot so that the area with the color that you want to detect
is brought within the detection area frame. To decide on the
color for the detection, press the SHUTTER dial to set SKIN
COLOR DET. to STOP.
• The areas recognized by the skin detail function appear
with superimposed zebra patterns.
• If the color is not recognized as a color that the skin detail
function works with, "ERROR" is displayed on the screen.

7. If you want to change the color range recognized by the
skin detail function, perform the following operations.
Set the SKIN COLOR DET. item to EXECUTE.
1 Turn the SHUTTER dial to align the cursor (>) with SKIN
COLOR RANGE, and then press the SHUTTER dial in the
direction of the arrow.
a The area with the setting value starts blinking, and
the value can now be changed.
2 Turn the SHUTTER dial up or down to widen or narrow the
color range.
• Adjust the range while observing the zebra patterns.
3 To decide the color range, press the SHUTTER dial in
the direction of the arrow.
a The setting value stops blinking but remains lit.

8. To stop the SKIN COLOR ADJUST operation, align the
cursor (>) with BACK PAGE and press the SHUTTER dial
in the direction of the arrow.

SKIN COLOR ADJUST screen

84

13. FEATURES OF THE CAMERA SECTION

13-6 How to Use Skin Detail (Cont’d)
n Confirming the color tone area adjusted
with the Skin Detail function
When the ZEBRA switch on the front section is pressed to the
“SKIN AREA” side, the color tone areas adjusted with Skin Detail
are displayed in the viewfinder.

OFF
ON

ZEBRA
SKIN
AREA

AUTO
WHITE
ACCU
FOCUS

VTR AUDIO
LEVEL CH-1

TAKE

ZEBRA switch

ACCU - FOCUS

n Using the Skin Detail Function

G

To use the skin detail function set on the SKIN COLOR ADJUST
screen, set the SKIN DTL DETECT item on the PROCESS
menu to “ON”.

F
I
SD
B

"SD"
display

While the Skin Detail function operates, the “SD” indicator is
displayed on the Status 0 and Status 1 screen in the viewfinder.

STATUS 0

85

14. OTHERS
14-1 Troubleshooting
Warnings concerning problems with the unit are provide in the form of indicators, display indications and monitor tones.
The warnings are of the following two types.
• Alarm indications : These indications are given to provide warning on the status of the unit, for example when the tape or battery
pack should be replaced.
• Error code display : In case an error occurs during operation, the unit self-diagnoses the cause and shows the diagnostics results
on the counter display. When this happens, the unit stops operation automatically or ejects the videocassette.

ALARM INDICATIONS
SERVO
indicator

WARNING indicator

RF indicator

CH 1
40 30
OPERATE/WARNING

CH 2
32k
AUD LOCK

LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

20

OVER
0 dB
OVER

10

48k

PB

Li indicator

AUTO OFF DEW
SERVO RF L i
NDF

HOLD

SP

MENU
CH-1
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

GAIN

OUTPUT

ON

M

B

REV FWD

S

F

E BATT F

WHT.BAL

TALLY lamp

POWER

NG

H

REMAIN
PRST A

BARS CAM

HML

SAVE STBY

VTR

MENU

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

OFF ON
AUTO KNEE

AUTO IRIS

OFF

H

M

Remaining tape
time display

ALARM

Remaining battery
power display

When an alarm is indicated, the unit operates in the following ways.
Alarm Indicator
on VCR Display

Symptom

VCR Operation and Remedy

DEW

Indicates dew formation (condensation).

SERVO
(Counter display)
“SYnc inh”

Lights in the case of troubles with the drum servo
during recording. Lights when the input sync
signal is disturbed or the unit is subjected to
physical shock. (Displayed only in record mode)

RF
(Counter display)
“HEAd CLoG”

Lights in case of video head clogging.
(Head clogging is detected and indicated during
playback and recording check using the RET
button on the lens section.)

Operation : Continues.
Remedy : Clean the head with the special head
cleaning tape. (See page 7 and the
separate sheet “Precautions for Use
of Head Cleaning Tape”.)

(Counter display)
Pc TAPE

Improper cassette type

Li

Lights when the lithium battery for backup of time
code generator and date/time data is exhausted.

Remaining tape time

* About 2 minutes before tape end. (The TALLY
lamp and alarm sound are activated only in
the record mode.)

Operation : Operation stops.
Remedy : Use recordable MiniDV cassette for
recording video and audio.
Operation : Continues.
Remedy : Replace with a new lithium battery.
See page 34.
Operation : Continues.

REMAIN
H

M

Remaining battery power

* When the tape has ended completely.

Operation : Stops.

When the remaining battery capacity is low.

Operation : Continues.
Remedy : Replace battery pack early.

When the battery capacity drops to an insufficient
level.

Operation : Stops automatically.
The camera may generate abnormal signals.
This is not a malfunction.

E BATT

E BATT

86

Operation : The VTR rejects operation.
Remedy : Leave the power on, and wait until
the indication disappears.
Operation : During recording the mode becomes
the stop mode.
During playback, playback of the
disturbed video image continues.
Remedy : • Also check the input sync signal.
• Signal is disturbed when the unit
is subject to a violent shock.
In other cases, please consult the person in
charge of professional video equipment at your
nearest JVC-authorized service agent.

14. OTHERS

14-1 Troubleshooting (Cont'd)
Alarm Indications (Cont'd)
Depending on the alarm conditions, the warning indicators in the LCD display, the WARNING indicator, the TALLY lamp, alarm
tones and the viewfinder appear as shown in the following table.
Alarm Indications
LCD Display

TALLY Alarm Tone
Indicator Lamp
WARNING

Viewfinder
WARNING Lamp
REC Lamp

"DEW"
indicator

On Screen Display

BATT. Lamp

VTR WARNING (DEW)

"SERVO"
indicator
"SYnc inh"
indicator
"RF"
indicator
"HEAd CLoG"
indicator

VTR WARNING (SERVO)

VTR WARNING (HEAD)
(Only during the interval from when the VTR trigger
button is pressed and until recording starts.)

"Li"
indicator
Remaining
tape time

TAPE NEAR END

REMAIN
H

M

(In record mode only)

About 2 min. before tape end.

TAPE END
Remaining
battery power

E BATT

E BATT

(Except for play
/search mode)

LOW BATTERY

LOW BATTERY

Viewfinder
On Screen
Display
VTR WARNING (SERVO)

REC

BATT lamp

BATT

ALARM

REC lamp

87

14. OTHERS

14-1 Troubleshooting (Cont'd)
WARNINGS IN VIEWFINDER
Viewfinder Warning Lamps

1.

When an abnormality occurs in the unit or an improper operation
is performed, one of the following warning messages will appear
in the viewfinder.

REC
BATT

ALARM

Battery lamp

2.
REC/ALARM lamp

1. BATTERY lamp
This red lamp lights under the following circumstance.
Lights red : • When the battery voltage becomes too low
for the camera to operate.

2. REC/ALARM lamp
This lamp lights or blinks green under the following
conditions.
Lights Green : • While recording
Blinks Green : • During the interval where the unit
switches from record-pause to record
mode.
• Immediately before the tape runs out or
has run out.
• If the unit malfunctions.
n Character display warnings:
LOW BATTERY

: This blinks when the battery level
becomes too low.
TAPE NEAR END : Less than 3 minutes tape remaining.
TAPE END
: The tape has run out.
n Function Failures

• VTR WARNING (HEAD):
Lights in case of video head clogging.
(Head clogging is detected and indicated during playback
and recording check using the RET button on the lens
section.)
• VTR WARNING (SERVO):
Lights in the case of drum servo trouble during recording.
• VTR WARNING (DEW):
Lights when condensation occurs in the unit.
• VTR WARNING (STOP):
Lights in case the unit stops operating.
• VTR WARNING (HARD):
Lights when abnormality occurs in the unit.
• VTR WARNING (REW):
Lights when abnormality occurs with tape rewind operation.
• CLOSE CASSETTE COVER:
Lights when the cassette cover has not been closed.
• REC INHIBIT:
Indicated when an unrecordable videocassette (the switch
on the back of the cassette is set to SAVE) is loaded.
• NO TAPE:
Lights when the VTR trigger button is pressed with no
videocassette loaded.
n Warnings on the White Balance Function

V T R WA RN I NG ( H E A D )

Status 0 or
Status 1 mode

• AUTO WHITE A, B
NG: OBJECT

Improper object.
• Check whether the object being
shot is white enough.
• Check that selected filter suits the
• AUTO WHITE A, B
illumination conditions.
ERROR: LOW LIGHT Amount of incident light insufficient.
• Check to see if it is necessary to
increase illumination or perform
• AUTO WHITE A, B
iris adjustment.
ERROR: OVER LIGHT Amount of incident light excessive.
• Check to see if illumination and iris
adjustment are appropriate.

A U T O WH I T E A
NG : OB J E C T

88

14. OTHERS

14-1 Troubleshooting (Cont'd)
In the case of troubles occurring during operation of the GY-DV500, it performs a self-test to identify the cause and displays the
result in the form of an error code. The error code consists of the "main code" which indicates its contents and the "sub-code" which
indicates the details. Depending on the status of the GY-DV500 at this time, indications may also appear on the LCD display, the
WARNING indicator may activate and the alarm tone may be generated.
In the viewfinder, the "VTR WARNING (DEW)" indication appears when condensation is detected, and the "VTR WARNING (STOP)",
"VTR WARNING (HARD)" or "VTR WARNING (REW)" indication appears depending on the contents of the error code when some
of the other error codes are displayed.
WARNING indicator
TALLY lamp

VTR WARNING (HARD)

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

MENU
CH-1 AUDIO CH-2

LEVEL
FULL AUTO BLACK

GAIN

B
PRST A

BARS CAM

HML

SAVE STBY

VTR

TALLY
lamp

STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

VTR WARNING (DEW)

LOLUX

OFF ON
AUTO KNEE

AUTO IRIS

L
OUTPUT WHT.BA

POWER

NG
ON

OFF

EARPHONE

ALARM
tone
Auto-OFF indicator:
Lights depending on the error code.
When this indicator lights, the
GY-DV500 will automatically stop
operation or eject the cassette. The
GY-DV500 does not accept any
operation.

Dew condensation
indicator

AUTO OFF

DEW

Main code
Sub-code

WARNING indicator

Alarm Tone

Display

Red. blinking

Continuous

"Error code"

• Automatically ejects the cassette. It can be inserted again.

"Error code"
plus
"AUTO OFF"

• Automatically stops operation or ejects the cassette.
(Auto OFF) * The GY-DV500 does not accept any operation.

"DEW "

• Dew condensation inside the unit.
The GY-DV500 does not accept any operation until the DEW indicator
disappears from the display.

Red, blinking

Intermittent

GY-DV500 Operation

* In the Auto OFF status, it is impossible to operate the GYDV500. This condition can be cancelled by switching the
POWER switch OFF and then switching it ON again. If the
same problem occurs again after the power is turned ON,
there may be something wrong with the GY-DV500. Please
consult the person in charge of professional video equipment
at your nearest JVC-authorized service agent.

The GY-DV500 is a microcomputer-controlled piece of
equipment, which may malfunction due to external noise
or interference. In this case, set the POWER switch to OFF,
remove the lithium backup battery, and then set the
POWER switch to ON again after a few minutes.

89

14. OTHERS

14-1 Troubleshooting (Cont'd)
TROUBLES WITH ERROR CODE OUTPUTS
Error Code

Error Details

GY-DV500 Operation

Remedy
Switch the power OFF and then
switch it back ON. However, the tape
may be damaged depending on the
situation. Please consult the person
in charge of professional video
equipment at your nearest JVCauthorized service agent.

3200

Tape loading impossible.

Operation stops. All operations
are rejected.

3300

Tape unloading impossible.

Operation stops. All operations
are rejected.

4100

Irregular eject operation.

Operation stops. All operations
are rejected.

4200

Cassette housing abnormality.

Operation stops. All operations
are rejected.

5605

Tape is cut.

Operation stops. All operations
are rejected.

Open the cassette cover by using the
EJECT switch and then switch the
power ON again.

5606 to 5607

Tape is slack.

Operation stops. All operations
are rejected.

5702

Tape end sensor error.

Operation stops. All operations
are rejected.

5802

Tape beginning sensor error.

Operation stops. All operations
are rejected.

Switch the power OFF and then
switch it back ON. However, the tape
may be damaged depending on the
situation. Please consult the person
in charge of professional video
equipment at your nearest JVCauthorized service agent.

7001

Drum rotation stopped.

Operation stops. All operations
are rejected.

7101

Capstan rotation stopped.

Operation stops. All operations
are rejected.

7202 to 7203

Supply reel rotation error.

Operation stops. All operations
are rejected.

7302 to 7303

Take up reel rotation error.

Operation stops. All operations
are rejected.

7305

Irregular tape winding when
unloading.

Operation stops. All operations
are rejected.

90

Switch the power OFF and then
switch it back ON. However, the tape
may be damaged depending on the
situation. Please consult the person
in charge of professional video
equipment at your nearest JVCauthorized service agent.

14. OTHERS

14-1 Troubleshooting (Cont'd)
TROUBLES WITHOUT ERROR CODE OUTPUTS
Symptoms

Remedy

Power cannot be switched ON.

• Is power supply connected properly?
• Is battery pack recharged?
• When the lithium battery is depleted, it may not be possible to turn on the power.
• Was the power turned ON immediately after being turned OFF?
Wait at least 5 seconds before turning the power ON again once it has been turned
OFF.

Operation buttons on the GY-DV500 don't
work.

• Is the cassette cover open?
The GY-DV500 remains inoperative as long as the cassette door is open.

Recording is not possible.

• Is switch on cassette set to REC? If it is set to SAVE, set it to REC.
• When not connected via the DV connector, is the VCR Setup Menu item No. 126
INPUT SELECT set to “IEEE1394”?
If so, set to “CAMERA”.

Even if the image appears in the
viewfinder, the signal is not output to the
MONITOR OUT or YC OUT connectors.

• When not connected via the DV connector, is the VCR Setup Menu item No. 126
INPUT SELECT set to “IEEE1394”?
If so, set to “CAMERA”.

Noise interferes with playback video.

• Video head may be clogged with dirt. Clean head with the special head cleaning
tape. (See page 7 and the separate sheet “Precautions for Use of Head Cleaning
Tape”.)

Sound and picture are disturbed during
playback.

• Is the sync signal input to the SYNC IN connector disturbed? If so, check and
remedy the input sync signal.

Time code data is not shown as onscreen-display.

• Time code data is not shown as on-screen-display during recording or playback.
The data is shown only on the counter display.

Time code and user's bit data are not
shown on the counter display.

• Is the COUNTER switch set to "CTL"? If so, set the switch to "TC" or "UB".

Remaining battery power display is
incorrect.

• The VCR Setup Menu item No. 396 BATTERY TYPE may not be set correctly in
accordance with the type of battery in use. If the menu item setting is incorrect, set
it correctly using the VCR setup menu item BATTERY TYPE.
• Is the battery old?

Battery alarm is displayed and the GYDV500 enters the non-operating mode
even when a fully charged battery is used.
Cassette cannot be ejected after the
power is turned ON.

• The capacity of the power supply may be insufficient. Check the power voltage.

Viewfinder image looks dark or unclear.

• Adjust the viewfinder's contrast and bright controls.
• Is the filter turret set to 5600K+ND?
• Is the iris closed?
• Is the shutter speed too fast?
• Is the viewfinder cable correctly connected?

Noise appears when playing back a tape
recorded on another unit.

• When a tape recorded on another unit is played back or used for recording, this
phenomenon may occur due to tracking errors.

The transient section between scenes
recorded on other units and those
recorded on this unit may appear
disturbed.
The front section's recording level control
doesn’t work.

• Is the VCR Setup Menu item No. 246 FRONT VOLUME ENABLE set to "DISABLE".
If so, set to "ENABLE".

The front section's recording level control
doesn’t change the recording level of the
sound input to CH2.

• The front section's recording level control cannot be used to change the recording
level of the sound input to CH2. Use the side section's CH2 recording level control
for this purpose.

Recording operation stopped.

• Is the SERVO indicator or “SYNC INH” displayed on the counter display?
If so, check the input sync signal.

91

14. OTHERS

14-2 Hour Meter Display
The unit can display the accumulated running time of the head drum as hour meter data on the counter display. The hour meter can
be displayed by selecting HM (HOUR METER) on the VCR Setup Menu. Use this as a guide for periodical maintenance.
☞ See page 7.
Note:
The hour meter is not shown correctly when no
videocassette is inserted.

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

CH-1

SHUTTER STATUS

MONITOR

AUDIO
LEVEL

CH-2
CH-1

LEVEL
FULL AUTO BLACK
BACK L
NORMAL
SPOT L

CH-1

LOLUX

B

LITHIUM BATT.

PRST A

OFF ON
AUTO KNEE

BARS CAM

HML

GAIN

AL
OUTPUT WHT.B

ON

GROUP

ITEM

HOLD

SHIFT

SELECT

MENU

DATA SET

ADVANCE PRESET

2. 5.
MENU button

5. DATA SET button

POWER

NG

FREE
REC

CONTINUE

CH-2

FRONT
REAR

STRETCH
NORMAL
COMPRESS

SAVE STBY

VTR

PRESET
REGEN

AUDIO SELECT
AUDIO INPUT

CH-1 AUDIO CH-2
AUTO IRIS

TC GENERATOR

CH-2
AUTO
MANUAL

MENU

OFF

3. GROUP button

4. SELECT button

1. POWER switch

1. Set the POWER switch to ON.
2. Press the MENU button to display the VCR Setup Menu.

Counter display

Accumulated drum running time: 200 hrs.

Viewfinder

"MENU" lights in the display, and the VCR Setup Menu's
group menu appears in the viewfinder and on the counter
display.

( HOUR METER )
DH : DRUM HOUR METER
0 0 0 2 0 0H

3. Press the GROUP button and choose "HM: HOUR METER".
• "HM HOUR METER" is shown blinking in the viewfinder.
The counter display shows "Hour".

4. Press the SELECT button.
The accumulated running time of the head drum is indicated
in the viewfinder and on the counter display.

5. To return to the normal mode, press the DATA SET button.
• Pressing the MENU button returns you to the group menu.

92

14. OTHERS

14-3 Specifications
n CAMERA SECTION

n INPUT/OUTPUT SIGNALS

Image pickup devices:1/2-inch interline CCD x 3
Color separation optical system:
F1.4 3-color separation prism
Number of effective pixels:
380,000 pixels ((H) 768 x (V) 494)
Color system
: NTSC (R-Y, B-Y encoder)
Color bars
: SMPTE color bar
Sync system
: Internal sync (built-in SSG)
External sync (VBS or BB)
Lens mount
: Bayonet system
(compatible with 1/2-inch lenses)
Optical filter
: 3200 K, 5600 K, 5600 K + ND
Sensitivity
: F11, 2000 lx
Minimum illumination: 0.75 lx (F1.4, LOLUX mode)
Gain
: -3, 0, 6, 9, 12, 18 dB, ALC, LOLUX,
Shutter speed
: 1/100, 1/250, 1/500, 1/1000, 1/2000
V.SCAN speed
: 60.1 Hz to 2084.6 Hz
Registration
: 0.05% or less (excluding lens
distortion)
Contour correction : Horizontal: dual-edged. Vertical: 2 H

F.F/Rewind time

[VIDEO]
Recording format

: Mini DV (SP mode only)
: 18.812 mm/s
: 60 minutes
(With M-DV60ME cassette)
: Approx. 3 minutes 30 seconds
(With M-DV60ME cassette)

: 8-bit, 13.5 MHz, 4:1:1 component
recording

[AUDIO]
Recording format

: 16-bit, 48 kHz, 2-channel PCM
audio/12-bit, 32 kHz 2-channel
PCM audio
Frequency response : 20 Hz to 20 kHz (48 kHz mode)
Wow & flutter
: Below measurable limit

[Time Code System]
Time code signal

: 1 V (p-p), 75 ohms (BNC)
unbalanced composite output.
YC output
: Y 1 V (p-p) 75 ohms unbalance
C 0.286 V (p-p) 75 ohms
unbalance (4-pin)
Lens
: 12-pin connector
Audio input
: Microphone -60dBs, 3 kohm
balanced (XLR-4)
Line
+4dBs, 10 kohm
balanced (XLR-4)
Audio output
: -6 dBs, low impedance,
unbalanced
Earphone output
: -60 dBs to -17 dBs, at 8-ohm load
(Monaural mini jack)
DC input
: 12V DC (11 to 15 V DC) (XLR-4)
Auxiliary power output : 12 V DC, max. 0.1A (11 to 15 V DC)
(4-pin)
DV connector
: 4-pin
RS-232C
: Mini DIN 6-pin
n GENERAL

n VCR SECTION
Format
Tape speed
Record/Play time

Video signal output

Power consumption : 1 8 W w i t h V F - P 1 1 5 B ( w h e n
recording)
Mass
: Approx. 5.0 kg (with lens, viewfinder,
battery, videocassette). Approximately 2.9 kg (main unit only)
Operating temperatures : 0 °C to 40 °C
Operating humidity : 30 % RH to 80 % RH
Storage temperatures: -20 °C to 60 °C
n ACCESSORIES
Microphone
Tripod base
Lithium battery
Head cleaning tape
Instruction Manual
Precautions for Use of Head Cleaning Tape

:
:
:
:
:
:

x1
x1
x 1 (CR2032)
x1
x1
x1

: Compliance with SMPTE standard
Design and specifications are subject to change without
notice.

93

14. OTHERS

14-3 Specifications (Cont'd)
OPTIONAL ACCESSORIES
Viewfinder
Power zoom lens

: VF-P115B, VF-P116
: S14 x 7.3B12, S16 x 6.7B12, S19 x 6.5B12 (FUJINON)
YH14 x 7.3K12, YH18 x 6.7K12 (CANON)
: AA-P250
: MV-P615
: KA-A50

AC power adapter
Microphone
Microphone holder

EXTERNAL DIMENSIONS (unit: mm)

PUSH OPEN

OPERATE/WARNING
LIGHT
RESET

ON
OFF

MONITOR
SELECT

FILTER
1 3200k
2 5600k
3 5600k+ND

COUNTER
CTL
TC
UB

ALARM

SHUTTER STATUS

MONITOR

243

VF

MENU
CH-1
FULL AUTO BLACK

HML

SAVE STBY

GAIN

OFF
BARS CAM
AUTO KNEE
ON

VTR
OFF
ON

AUDIO CH-2
LEVEL

LOLUX
STRETCH
NORMAL
COMPRESS

BACK L
NORMAL
SPOT L

PRST A B

AUTO IRIS

BAL
OUTPUT WHT.

ZEBRA
SKIN
AREA

AUTO
WHITE

POWER

NG
ON

OFF

ACCU
FOCUS

VTR AUDIO
LEVEL CH-1

124

TAKE

302

26.5

* Design and specifications are subject to change without notice.

94

14. OTHERS

95

GY-DV500 @DV CAMCORDER

VICTOR COMPANY OF JAPAN, LIMITED

®
®

is a registered trademark owned by VICTOR COMPANY OF JAPAN, LTD.
is a registered trademark in Japan, the U.S.A., the U.K. and many other countries.

© 1999 VICTOR COMPANY OF JAPAN, LIMITED

Printed in Japan
SC96874-003



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Author                          : kawasima
Create Date                     : 2000:01:24 16:32:58Z
Modify Date                     : 2012:09:22 05:26:46+02:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Format                          : application/pdf
Creator                         : kawasima
Title                           : GY-DV500(U.S.A)/E(1).65J
Creator Tool                    : PageMaker 6.5J
Metadata Date                   : 2012:09:22 05:26:46+02:00
Producer                        : Acrobat Distiller 3.01 for Power Macintosh
Document ID                     : uuid:2d075386-d774-284a-8c14-31f68e24145b
Instance ID                     : uuid:074f8463-ebf0-504f-b3b8-c46e7bed968a
Page Count                      : 96
EXIF Metadata provided by EXIF.tools

Navigation menu