KATHREIN SE 86010148V01 Positioning tool for antennas User Manual Datenblatt 9364624a 86010148V01

KATHREIN-Werke KG Positioning tool for antennas Datenblatt 9364624a 86010148V01

user manual

Type No. 86010148V01Protocols compliant to AISG 1.1 and 3GPP/AISG 2.0Logical interface ex factory 1) 3GPP/AISG 2.0Input voltage range 10 ... 30 V (pin 1, pin 6)Power consumption < 1 W (stand by); < 10 W (motor activated)Connectors 2) 3) 2 x 8 pin connector according to IEC 60130-9; according to AISG Daisy chain in: male; Daisy chain out: femaleHardware interfaces RS 485A/B (pin 5, pin 3);power supply (pin 1, pin 6); DC return (pin 7);according to AISG / 3GPPAdjustment time (full range) 40 sec (typically, depending on antenna type)Adjustment cycles > 50,000Temperature range –40 °C … +60 °CProtection class IP 24Lightning protection AISG interface (each pin)2.5 kA (10/350 µs)8 kA (8/20 µs)Housing material Profi le: Aluminum anodized; cover: Aluminum die cast coatedWeight 455 g (0.99 lbs)Packing size 245 x 93 x 102 mm, (9.6 x 3.6 x 4 inches)Dimensions (H x W x D) 177.5 x 59.5 x 49.5 mm, (7.0 x 2.3 x 1.9 inches)1)  The protocol of the logical interface can be switched from 3GPP/AISG 2.0 AISG 1.1 to with a vendor specifi c command. Start-up operation of the RCU is only possible in a RET  system supporting 3GPP/AISG 2.0!The protocol can also be changed as follows: 3GPP to AISG 1.1: Enter “AISG1” into the additional data fi eld “Installer’s ID” and perform a layer 2 reset or a power reset. AISG 1.1 to 3 GPP: Enter “3GPP” into the additional data fi led “Installer’s ID” and perform a layer 7 reset or a power reset. After switching the protocol any other information can be entered into the “Installer’s ID” fi eld.Please note:If the Primary of the RET system doesn’t support the standard of the ‘logical interface ex factory’, the RCU must be switched to the appropriate standard of the Primary before installation. Please contact Kathrein for further information.2)  The tightening torque for fi xing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’). The connector should be tightened by hand or using the torque screwdriver (85010080) as described in the connecting cable data sheet (85010007, ...)3)  The RCU get‘s the information stored in the antenna after power on automatically if a corresponding antenna is used. It is not necessary to confi gurate the RCU manually.Standards: EN 60950-1 (Safety)EN 60950-22 (Safety – Equipment installed outdoor)EN 55022 (Emission)EN 55024 (Immunity)ETS 300019-1-4 (Environmental)UL 60950-1; 1st editionCertifi cation: CE, FCCScope of supply: Remote Control UnitAssembly pasteKATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820www.kathrein.de 86010148V01   Page 1 of 5936.4624/a     Subject to alteration.Remote Control Unit (RCU)Remote Control Unit (RCU) for Kathrein base station antennas with adjustable  electrical down-tilt and appropriate mechanical interface.● Compliant to AISG 1.1 and 3GPP/AISG 2.0  ● Daisy Chain feasibility● Compact size  ● Suitable for operation under outdoor condition● Automatic Confi guration173.6 mm(6.8ʺ)33.2 mm(1.27ʺ)M42x1.528.5 mm(1.1ʺ)Ø 46 mm(Ø 1.8ʺ)59.5 mm(2.34ʺ)49.5 mm(1.95ʺ)8 mm(0.31ʺ)Daisy chain in(male)Daisy chain out(female)Bottom view of RCU
Please note:  Additional grounding of the RCU is not required if the RCU is fi xed to an antenna with proper ground-ing. Please assure that grounding of the antenna has been carried out according to all relevant local  regulations.Please note: As a result of more stringent legal regulations and judgements regarding product liability, we are  obliged to point out certain risks that may arise when products are used under extraordinary  operating conditions.The mechanical design is based on the environmental conditions as  stipulated in ETS 300 019-1-4 and thereby respects the static mechanical load imposed on an  antenna by wind at maximum velocity. Wind loads are  calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional  dynamic stress (e.g. strain caused by oscillating support structures), may result in the  breakage of an  antenna or even cause it to fall to the ground. These facts must be considered during the site planning process.The installation team must be properly qualifi ed and also be familiar with the relevant national safety regulations.The details given in our data sheets have to be  followed carefully when installing the antennas and  accessories.The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must be obeyed.Any previous datasheet issues have now become  invalid.KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820www.kathrein.dePage 2 of 5   86010148V01936.4624/a     Subject to alteration.Remote Control Unit (RCU)Description of the adjustment mechanism (protective cap removed):➀  Adjustment wheel with twist-lock function.➁  Downtilt spindle with integrated scale.➀  Thread for fi xing the pro tective cap or the RCU (Remote Control Unit).➁  Gearwheel for RCU power drive.To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gear-wheel must be used for alignment.1221
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820www.kathrein.de 86010148V01   Page 3 of 5936.4624/a     Subject to alteration.Instructions for RCU InstallationAttaching the RCU (Remote Control Unit) for remote-controlled downtilt adjustment:Twist off the protective cap com-pletely from the antenna.Check the proper function of the phase shifter over the  entire adjustment range by twisting the adjustment wheel in such a way, that the spindle moves completely in and out.Reset the downtilt to 0 degree.Completely remove the black  adjustment wheel by simply  pulling it downwards.Clean the thread surface. Apply the assembly-paste evenly onto the full circumference of the thread as illustrated in the fi gure.Note!Avoid ingestion and contact with eyes.In case of contact with eyes rinse thoroughly with plenty of water. In case of irritation seek medical advice.Avoid long-term contact with skin.In case of contact with skin wash off with soap and water.For further information please read the safety data-sheet ‘Klüberplex AG 11-461’ by companyKlüber Lubrication München KGGeisenhausenerstraße 7D-81379 Münchenhttp://www.klueber.comPush the attachment nut of the RCU down towards the housing.Place the RCU carefully over the adjustment spindle, observ ing the correct alignment of the RCU with regards to the antenna, i.e. the fl at surfaces of the attachment fi xture on the antenna side and those inside the RCU housing must lie fl at against each other.Push-up the RCU carefully to the stop at the antenna.Please note!Do not twist the RCU during  attaching to the antenna, as this may damage the adjust-ment spindle.Tighten the RCU attachment nut using a torque-wrench; wrench width = 41 mm, min. torque = 15 Nm,max. torque = 18 Nm.Connect the RCU control cable immediately after attachment of the RCU. The tightening torque for fi xing the control cable connec-tor must be 0.5 – 1.0 Nm (‘hand-tightened’).Please note!In cases where a mechanical downtilt unit is installed, this must not be set for a downtilt of more than 14 degrees.Connecting the control cables:Connect a control cable to the daisy chain input of the RCU.The tightening torque for fi xing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’).The connector should be tightened by hand only!Please note: If the daisy chain output is not used, do not remove the protection cap.For daisy chain operation, remove the protection cap and attach a control cable to interconnect with the daisy chain input of the subsequent RCU.Please note: Do not remove the protection cap on the daisy chain output of the last RCU device.
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820www.kathrein.dePage 4 of 5   86010148V01936.4624/a     Subject to alteration.FCC – StatementsFCC – Statements  FCC § 15.19 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC § 15.105 Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Canada CNR-Gen Section 7.1.3 This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. ICES-003 This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  FCC § 15.21 (Warning Statement) [Any] changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820www.kathrein.de 86010148V01   Page 5 of 5936.4624/a     Subject to alteration.FCC – StatementsCompliance Information Statement (Declaration of Conformity Procedure) Responsible Party:  Kathrein Inc., Scala Division Address:  PO Box 4580, Medford Oregon . 97501 Telephone: (+01)541 779 6500 Type of Equipment:    Model Name: Remote Control Unit (RCU)   FCC ID SP3-86010148V01

Navigation menu