KERLINK KLK915WIFC LoRa gateway for IoT chain User Manual
KERLINK SA LoRa gateway for IoT chain
KERLINK >
User Manual
User Manual User Manual of Wirnet iFemtoCell 1 Normal conditions of use The Wirnet iFemtoCell is an indoor LoRa Nano Gateway for IoT chain. It is based on LoRa® technology provided by Semtech Company, it is compatible and interoperable with existing LoRa LPWAN. The Wirnet iFemtoCell is declined into three versions to cover different countries and areas around the world: Geographical area ISM band Downstream bandwidth (Tx of the Wirnet iFemtoCell) Upstream bandwidth (Rx of the Wirnet iFemtoCell) Certifications Wirnet iFemtoCell 868MHz Wirnet iFemtoCell 915MHz Europe, Russia Africa Middle East, India North America Central America South America with the exception of Brazil 863 - 876 MHz 902 - 928 MHz Wirnet iFemtoCell 923MHz Asia: Indonesia, Malaysia, Korea, Japan, Taiwan, Hong Kong, Thailand, Vietnam, Papua New Guinea, Singapore, Philippines Oceania: Australia, New Zealand Brazil 915 - 928 MHz 863 - 873MHz 902 - 928 MHz 915 - 928 MHz 863 - 873 MHz 902 - 928 MHz 915 - 928 MHz EN 300 220 FCC and IC CB scheme for: Mexico, Argentina, Chile, Bolivia, Colombia, Venezuela, Uruguay, Peru, Ecuador FCC and EN 300 220 CB scheme for: Japan, Korea, Australia, Singapore, Indonesia, New-Zealand, Brazil Please check the appropriate version for the dedicated country. Contact your reseller if required. The present document addresses all the above Wirnet iFemtoCell versions. 2 Description of features Here are the main functionalities of the Wirnet iFemtoCell: LongRange support: o Incorporate LoRa (TM) bidirectional communications technology: 868MHz version RX: 863- 873MHz , TX: 863-873MHz (according to HW capabilities) 915MHz version 902-928 MHz ISM band-hybrid mode (according to HW capabilities) 923MHz version RX: 915-928 MHz, TX: 915-928MHz (according to HW capabilities) o 49 LoRa demodulators over 9 channels + 1 x GFSK Embedded, remote and open low power communication station Open development framework based on standard Linux OS Internet connectivity over Wi-Fi, Ethernet or 3G/4G (with optional USB dongle) USB host interface allowing local software upgrade with USB mass-storage key 3 Safety 3.1 Warnings in this manual Warnings provide important safety informations. Warnings must be read before any action is taken that poses risks to persons or equipment. WARNING 3.2 Refers to a critical situation. In case of non-compliance, it may result in property damage. Refers to useful information during manipulations. Safety instructions Please read this user manual carefully. It is an integral part of the described equipment and it must be available at all times. User Manual • • • • • WARNING Only use the Wirnet iFemtoCell for its intended use, see chapter 1 "Normal conditions of use". Only use the Wirnet iFemtoCell in the normal operating conditions described in chapter 10 "Technical characteristics". Maintenance and repair must be carried out by qualified personnel authorized by the manufacturer. The enclosure of the Wirnet iFemtoCell must not be opened by customer. The Wirnet iFemtoCell should only be used with accessories or spare parts supplied by your reseller. 4 Overview of Wirnet iFemtoCell 14 10 11 15 12 13 (EU version used here as example non contractual view) Nomenclature: N° Components Wirnet iFemtoCell Silkscreened KERLINK marking Jack connector (for power supply) USB connector RJ45 connector (Ethernet) N° 10 11 12 13 3 bicolor LEDs 14 Wall mounting oblong holes Sticker with markings 15 16 Components SMA connector for LoRa antenna Silkscreened Wi-Fi (WPS) marking Wi-Fi (WPS) push button Silkscreened Reset marking Reset push button LoRa antenna (862-873MHz , 902-928MHZ, 3dBi, 50Ω; vertical polarization) AC power supply User manual (this document) 5 Markings 5.1 Markings on sticker Symbol Wirnet iFemtoCell Description Type of equipment Power supply informations Board ID Final product ID MAC ADDR Symbol Description QR code or other marking CE marking indicating that the product complies with current European directives, or other marking depending on the country Serial number of board Marking indicating that the product complies with RoHS directives Serial number of product Do not dispose of with domestic waste MAC address Product must be installed on a non-flammable substrate (UL 94V0) Refer to the installation instructions before powering up User Manual 5.2 Markings on packaging Symbol Wirnet iFemtoCell Final product ID Packaging ID Software version MAC ADDR Description Symbol Type of equipment Serial number of product Description QR code or other marking CE marking indicating that the product complies with current European directives, or other marking depending on the country Identifier of packaging Marking indicating that the product complies with RoHS directives Version of embedded software Do not dispose of with domestic waste MAC address Product must be installed on a non-flammable substrate (UL 94V0) Refer to the installation instructions before powering up 6 Installation of Wirnet iFemtoCell 6.1 Mounting of the enclosure WARNING The Wirnet iFemtoCell enclosure must be mounted on any concrete pedestal, concrete wall or any non-flammable surface (UL94-V0). It must not be mounted on a flammable surface. The Wirnet iFemtoCell may be mounted on a wall using the two oblong holes. Only two screws (not included) are needed, all mounting informations are mentioned on the following drawing: 6.2 Setting connections WARNING Before setting all connections, ensure that the power supply is not connected to the mains supply. When the Wirnet iFemtoCell is installed, three configurations are possible regarding the technology used to access Internet: Ethernet connection, requiring an Ethernet access through a dedicated RJ45 cable Wi-Fi connection, requiring a Wi-Fi access point 3G/4G connection via USB dongle (optional) and an USIM subscription (not included) The three configurations may be used in parallel. A typical example is the possibility to insure Ethernet backup by a 3G/4G link. The required connections needed to operate the Wirnet iFemtoCell are listed below (see chapter 4 “Overview” for details of connectors): Power supply Ethernet cable (not included) LoRa antenna USB mass-storage key (not included) 3G/4G USB dongle (optional) and an USIM subscription (not included) The Ethernet cable is not provided and must consist of two RJ45 T 568A (or 568B) plugs on each side. KERLINK recommends using a cable with the following characteristics: • Category: 6A • Shielding: STP (U/FTP) or SSTP (S/FTP) • Section conductors: AWG26 • External jacket: LSZH or PUR • Maximum length: 100 meters • Operating temperature range:-20°C to +55°C In case of 3G/4G connection with USB dongle: • KERLINK recommends using a validated USB dongle (contact your reseller to have the list of validated USB dongles). Alternative dongle may require additional drivers and firmware update to be used. • To optimize the radio performances, when possible, KERLINK strongly recommends dissociating the 3G/4G USB dongle away from the enclosure and the LoRa antenna by using a 1 meter extension cable. User Manual 6.3 Power ON Once the LoRa RF antenna, the Ethernet cable (if used) or the optional 3G/4G USB dongle (with USIM card inserted) and the power supply jack connector are connected, the Wirnet iFemtoCell can be powered ON by connecting the power supply onto the 230VAC mains supply. 6.4 The power supply is provided with E/F type cable (Europe) or B type cable (USA). First connection When the Wirnet iFemtoCell is installed, the first connection can be done by two different ways: Using Wi-Fi connection: o Press the WPS button (Wi-Fi Protected Setup) on the Wirnet iFemtoCell (see chapter 4 “Overview”) then press the WPS button on the Wi-Fi access point of the installation o The connection will be established automatically Using Ethernet connection: o Plug the Wirnet iFemtoCell to your box or internet router with an Ethernet cable o The connection will be established automatically 6.5 Functional check To ensure the Wirnet iFemtoCell is started up, check the behavior of the LED indicators: LED LED 1: Power Specification RED blinking during the kernel boot GREEN blinking during system boot GREEN when boot is finished RED during boot If the applicative software provided by KERLINK is installed: • RED if applicative software is disconnected • GREEN blinking during applicative software connection • GREEN fix if applicative software is connected RED during boot If the applicative software provided by KERLINK is installed: • Applicative software management • Rx: GREEN blinking • Tx: RED blinking LED 2: Backhaul LED 3: LoRa traffic 6.6 Applicative software stands for embedded software running on the Wirnet iFemtoCell like KERLINK Small Private Network or another Packet Forwarder (software that forwards RF packets received to a server and emits RF packets that are sent by the server). Please contact your reseller to know the LEDs behavior if the applicative software installed on the Wirnet iFemtoCell is not the one officially provided by KERLINK. Configuration Once the connection is established (Ethernet or Wi-Fi), a Web configuration interface is accessible from the Wirnet iFemtoCell. This Web interface is accessible on any IP address that has been allocated by the network. You first have to get the IP address that has been allocated to the Wirnet iFemtoCell by DHCP on either Ethernet or Wi-Fi and then point your Web browser to it. You can find this information from your Wi-Fi/Ethernet router on its administration interface. For example: http://192.168.1.13/ The login credentials are “admin” for user and “admin” for password. User Manual The Web interface allows to configure the following items: Ethernet setup (frame 1): o IPV4 configuration: manual or automatic (DHCP) o In case of manual configuration: Address Netmask Gateway Wi-Fi setup (frame 2): o Network name o Password o IPV4 configuration: manual or automatic (DHCP) o In case of manual configuration: Address Netmask Gateway The Web interface allows to get some status (frame 3): Hardware status: o CPU used o RAM used o System disk used o User disk used Software versions: o Linux o Firmware 7 Problems Problem Cause The LEDs never turn on The Wirnet iFemtoCell is not well powered No LoRa data received The LoRa antenna is not well connected No Internet access No technology to access Internet is activated/available on the Wirnet iFemtoCell How to fix? • Check the position/good connection of the power supply jack connector • Check that the power supply is properly connected to the mains supply • Check that a LoRa endpoint is within range of the Wirnet iFemtoCell • Check the tightening of the LoRa antenna (SMA connector) • Check that the LoRa antenna is not deteriorated In case of Ethernet connection: • Check the position/good connection of the RJ45 Ethernet connector • Check that the RJ45 cable is not deteriorated In case of Wi-Fi connection: • Check that the Wi-Fi access point is within range of the Wirnet iFemtoCell In case of 3G/4G connection: • Check that the USB dongle is well plugged • Check that the USB dongle is well supported by firmware In case of a problem that cannot be resolved immediately from the table, contact your reseller. Do not use the Wirnet iFemtoCell to prevent further damage. User Manual 8 Disposal / Recycling Do not dispose of the product with domestic waste. For proper disposal, contact a waste disposal company. The packaging of the product (cardboard and liners) can be disposed of with the used paper. 9 Warranty Contact your reseller for warranty conditions of the Wirnet iFemtoCell. WARNING The Wirnet iFemtoCell is not warranted by KERLINK in case the enclosure is opened by customer for any reason. 10 Technical characteristics Characteristic Enclosure material LED gasket material Dimensions L x H x P in mm: • Without LoRa antenna • With LoRa antenna Weight in g (with AC power supply and LoRa RF antenna) Operating temperature range Power supply output voltage Power consumption: • CPU module (20% load), Ethernet link ON • Wi-Fi (25%Tx,75%Rx) • 3G/4G USB dongle (HSPA, 25% Tx, 75% Rx) • Radio in Rx mode (x8 demodulator on) Ingress protection Humidity Impact resistance Flammability rating Connectors Wirnet iFemtoCell PC + ABS Elastomer compound based on styrene-butadiene-styrene (SBS) 160 x 90 x 35 mm 220 x 125 x 35 mm 280g Enclosure: -20°C to +55°C Power supply: country dependent, please refer to power supply itself or contact your reseller 12 VDC 1.3W max 0.5W max 1W max 1.6W max IP31 / EN 60529 95% non-condensing IK07 UL94-V0 1 x SMA or RP-SMA (LoRa antenna) 1 x jack connector (power supply) 1 x USB 1 x RJ45 11 Declaration of conformity 11.1 Wirnet iFemtoCell 868MHz The Wirnet iFemtoCell 868 complies with requirements listed in the article 3 of the RED 2014/53/EU directive: 1. Electromagnetic compatibility (article 3.1-b of the RED Directive) Applied standard(s): EN 301 489-1 issue 1.9.2 EN 301 489-3 issue 1.6.1 EN 301 489-17 issue 2.2.1 2. Efficient use of the radio frequency spectrum (article 3.2 of the RED Directive) Applied standard(s): EN 300 328 issue 2.1.1 EN 300 220-1 issue 3.1.1 EN 300 220-2 issue 3.1.1 3. Safety (article 3.1-a of the RED Directive) Applied standard(s): EN 60 950-1 Ed. 2006+A11:2009+A1:2010+A12:2011+A2:2013 Magnetic field exposure Applied standard(s): Ed. 2002 4. EN 50 385 User Manual The Wirnet iFemtoCell 868 is considered as a category 2 receiver according to the EN 300 220-1. The Wirnet iFemtoCell 868 has CE marking. In Europe, the Wirnet iFemtoCell 868 station must comply with the ERC 70-3 requirements regarding duty cycle and maximum EIRP. They are summarized in the following table: ERC 70-03 Band h1.3 h1.3 h1.4 h1.5 h1.6 h1.7 h2 h2.1 Annex2/c Frequency (MHz) 863-865 865-868 868-868,6 868,7-869,2 869,4-869,65 869,7-870 870-873 870-873 870-873 Power 14dBm ERP 14dBm ERP 14dBm ERP 14dBm ERP 27dBm ERP 14dBm ERP 14dBm ERP 14dBm ERP 27dBm ERP Duty cycle 0,1% 1% 1% 0,1% 10% 1% 0,1% 1% 2,5% The power supply of the Wirnet iFemtoCell 868 must be a limited power source. • If the LoRa antenna is changed, the output power must be adjusted to take into account the gain of the antenna to not overrule the ERC 70-3 regulation. • Be careful, some countries in Europe may have specific frequency range, EIRP and duty cycles regulations. Check the local regulations before installing and commissioning the Wirnet iFemtoCell 868. • For other countries, outside Europe, check the frequency range, the maximum EIRP and duty cycle allowed. 11.2 Wirnet iFemtoCell 915MHz The Wirnet iFemtoCell 915 complies to: IEC 60950-1:2005/A1:2009/A2:2013 UL 60950 -1 : 2007, Amendment A1:2011, Amendment A2:2014 CAN/CSA-C22.2 NO. 60950-1-07 / A1: 2011 / A2: 2014 The Wirnet iFemtoCell 915 complies to both FCC and IC regulations. Applicable documents: CFR 47 FCC Part 15: o FCC 47 CFR Part 15 : 2016 - Part 15- Radio frequency devices o FCC PART 15.247 - Operation within the bands 902–928 MHz, 2400–2483.5 MHz, and 5725–5850 MHz (frequency hopping and digitally modulated) FCC Part 15.207 conducted emissions on AC mains in the band 150kHz – 30MHz FCC Part 15.247 intentional radiated emissions FCC Part 15.215 Additional provisions to the general radiated emissions limitations RSS 247: o RSP-100 Issue 11, January 2016 - Certification of Radio Apparatus o RSS-Gen – Issue 4, November 2014- General requirements and Information for the Certification of radio Apparatus o RSS-247 Issue 1, May 2015 - Digital Transmission Systems (DTSS), Frequency Hopping Systems (FHSS) and License-Exempt Local Area Network (LE-LAN) Devices The associated FCC and IC identifiers of the Wirnet iFemtoCell 915 are: Model: Wirnet iFemtoCell 915 FCC ID: 2AFYS-KLK915WIFC IC: 20637-KLK915WIFC The power supply of the Wirnet iFemtoCell 915 must be a limited power source. Any changes or modifications to this equipment not expressly by Kerlink may cause, interference and void the FCC authorization to operate this equipment. This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation of the device. User Manual WARNING • Some conditions have to be respected to maintain the FCC and IC compliance of the devices in USA and Canada. Please contact your reseller to have details. • For others countries, check the specific regulations regarding maximum EIRP and duty cycle allowed. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help This equipment complies with RSS102’s and FCC radiation exposure limits set forth for an uncontrolled environment under the following conditions: 1. This equipment should be installed and operated such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and user’s/nearby person’s body at all times. 2. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 11.3 Wirnet iFemtoCell 923MHz (certification on going) The Wirnet iFemtoCell 923 will be compliant to: IEC 60950-1:2005/A1:2009/A2:2013 CENELEC EN 60 950-1 (Ed. 2006/A11 : 2009/A1 : 2010/A12:2011/A2:2013) AS/NZS 60950.1 : 2011 GB4943-2011 K60950-1 J60950-1 The Wirnet iFemtoCell 923 will also be compliant to both FCC and CE regulations. Applicable documents: Article 3.2 of the RED Directive: Applied standard(s): o EN 300 220-1, issue 3.1.1 o EN 300 220-2, issue 3.1.1 o EN 300 328, issue 2.1.1 The Wirnet iFemtoCell 923 is considered as a category 2 receiver according to the EN 300 220-1. AS/NZS 4268 2017 : Radio equipment and systems – Short range devices – Limits and methods of measurement ARIB STD-T108 - 920MHz-Band Telemeter, Telecontrol and Data Transmission Radio Equipment Clause 2, Article 58-2 of Radio Waves Act (Republic of Korea) IMDA Technical Specifications for Short Range Devices (IMDA TS SRD) – Issue 1 Rev 1, October 2016 The power supply of the Wirnet iFemtoCell 923 must be a limited power source. • Depending on the countries, check the specific regulations applying, especially regarding frequency range, maximum EIRP, duty cycle allowed, maximum transmit duration, carrier sense mandatory or not… • Please contact your reseller to have details on specific rules for specific countries. 12 Contact For additional information, please contact your reseller.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Warning : Info object (114 0 obj) not found at 1060835EXIF Metadata provided by EXIF.tools