KROHNE OPTIWAVE7300C Radar Level Meter for operation within tanks User Manual aussen 6 x A5 Page 6

Krohne America Inc Radar Level Meter for operation within tanks aussen 6 x A5 Page 6

Exhibit 8 User manual

Download: KROHNE OPTIWAVE7300C Radar Level Meter for operation within tanks User Manual aussen 6 x A5  Page 6
Mirror Download [FCC.gov]KROHNE OPTIWAVE7300C Radar Level Meter for operation within tanks User Manual aussen 6 x A5  Page 6
Document ID455219
Application IDdPYso+y4LX9rNjEkGkqweQ==
Document DescriptionExhibit 8 User manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize107.15kB (1339343 bits)
Date Submitted2004-07-30 00:00:00
Date Available2004-07-30 00:00:00
Creation Date2004-03-28 16:35:25
Producing SoftwareAcrobat Distiller 5.0.5 f.r Macintosh
Document Lastmod2004-03-30 11:46:44
Document Titleaussen 6 x A5 (Page 6)
Document CreatorQuarkXPress(R) 3.32

Quick-start
© KROHNE 04/2004
7.02287.21.00
CH
OPTIWAVE 7300 C
Radar Level Meter
Measurement of distance,
level and volume of liquids,
pastes and solids
• Easy installation
• Wizard driven
• Service and maintenance-free
Items supplied
General
This is a quick-start guide only. For further information please consult the handbook, data sheet,
special manuals and certificates supplied on
CD-ROM.
Installation, assembly, commissioning and servicing must only be undertaken by trained
personnel. Maintenance which is considered
relevant to safety in the sense of explosion protection must only be carried out by the manufacturer, his agents or under the supervision of
experts.
*If applicable
For use in hazardous areas, special codes and
regulations are applicable, which are supplied in
a separate document that describes all ATEX
hazardous area information.
Visual check
ty
an
Warr
Responsibility as to suitability and intended use
of this device rests solely with the user. The supplier does not accept any liability resulting from
misuse by the customer. Improper installation
and operation of our level gauges may lead to
loss of warranty. In addition, the "General conditions of sale", found on the back of the invoice
and forming the basis of the purchasing contract, are applicable.
If you need to return the device to the manufacturer or supplier, please complete the form
given on the CD-Rom and attach to the device.
KROHNE regrets that it cannot repair or check
your device unless accompanied by this completed form.
Quick-start OPTIWAVE 7300 C
Handling and installation instructions
Antenna must protrude from nozzle base.
max. 2°
Handling and installation instructions
Option
max. 150°C / 300°F
+80°C / +175°F
min. -40°C / -40°F Viton
min. -20°C / -5°F Kalrez
-40°C / -40°F
Install away from
entry pipe.
DN 40 / 50:
> 1/7 H, but max. 1/3 D
Mount off-centre
to avoid multiple
reflections.
DN 80:
> 1/10 H, but max. 1/3 D
Special considerations
Avoid too many objects
near to the radar beam
in tank.
Stray
reflections !
Stilling wells and bypass chambers
Too many
objects in tank:
use bypass
chamber
Foam:
use stilling well
Dimensions and Weights
Flange (Antenna DN 80)
Antenna DN 80 with antenna extension
approx. 11 kg /24.3 lb
approx. 12 kg /26.5 lb
Note:
Additional antenna extension of
105 mm / 4.1" length available.
Dimensions and Weights
Flange (Antenna DN 40/50)
Thread
Dimensions in mm and inch
Antenna type
mm / inch
mm / inch
mm / inch
Antenna DN 40
39 / 1.5
38.5 / 1.5 343.8 / 13.5
Antenna DN 50
43 / 1.7
50 / 2
355.3 / 14
Note:
Cable glands are not delivered
with the device.
Terminal Compartment and Terminals
Wiring options
HART®
Configuration
Software
HHC
Non-Ex
HART®
Modem
min.250Ω
L–
L+
Connection procedure
• Unscrew terminal
compartment cover.
• Wire up using standard
procedures.
Explosion Proof (XP) / Ex d
• Apply grease to thread
of cover before closing.
Ex
HART®
Configuration
Software
HHC
non-Ex
HART®
Modem
min.250Ω
L–
L+
–
Intrinsically Safe (IS) / Ex i
Output 1
4 ... 20 mA/HART
or
3.8 ... 20.5 mA/HART
acc. to NAMUR NE 43
Ex
HART®
Configuration
Software
HHC
non-Ex
HART®
Modem
min.250Ω
Note: Other options how to connect the HHC and modem to the
HART® loop are available.
L–
L+
Quick-start OPTIWAVE 7300 C
Technical data extract
Application conditions
Temperature
Ambient temperature
-40…+80°C / -40…+175°F;
EEx i: -40…+60°C / -40…+140°F
Storage temperature
-40…+85°C / -40…+185°F
Flange temperature
-40…+150°C / -40…+300°F (Viton gasket)
-20…+150°C / -5…+300°F (Kalrez 6375 gasket)
Thermal shock resistance
100°C/min
Process conditions
Operating pressure
-1…40 bar / -14.5…580 psig;
subject to process connection used and flange
temperature
Dielectric constant
1.5
Vibration resistance
IEC 68-2-6 and prEN 50178
(10...57Hz: 0.075 mm / 57...150 Hz: 1 g)
Protection category
IP 66/67 equiv. to NEMA 6-6X
Output
Output signal
Output 1
4 … 20 mA HART® or 3.8 … 20.5 mA
acc. to NAMUR NE 43
Accuracy
0.05% (rel. 20 mA; 20°C / 68°F)
Resolution
±2 µA
Temperature drift
Typically 50 ppm/K
Error signal
High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43
Max. Load
350 ohm
Approvals
Overfill protection
WHG
ATEX
ATEX II G/D 1, 1/2, 2 EEx ia IIC T6;
ATEX II G/D 1/2, 2 EEx d ia IIC T6
FM
CSA
IS class I Div. 1 Gr. A...G; XP class I Div. 1 Gr. A…G
IS class I Div. 1 Gr. A...G; XP class I Div. 1 Gr. A…G
For futher data see data sheet, approvals and handbook on CD-ROM
Hotline: +33(0)4.75.05.44.00 · Fax: +33(0)4.75.05.44.97
www.krohne.com for local contacts · E-mail: level@krohne.fr
Human interface
Normal mode:
Selects type of
information
displayed.
Normal mode:
Selects display style.
Program mode:
Program mode:
Moves cursor to right or
selects next menu level.
ESC
Moves menu
selector up the
list or increments
parameter value.
Program mode:
Saves or confirms
parameter.
Normal mode:
Selects measurement
parameters to be displayed.
Program mode:
ESC-function returns to
previous menu. If top
menu reached, returns
to normal mode.
Any paramenter value
entered is not stored.
Program mode:
Moves menu selector down list
or decrements parameter value.
Human interface
Hot keys
Mode
Normal
Program
Normal
All modes
Hot key activated when:
☞
☞
☞
Enters program mode
3 seconds
☞
Saves current function
used as quick link
3 seconds
Active screen stored as
default screen
3 seconds
HMI will reset to default
language
3 seconds
Returns to normal mode
(last screen displayed)
3 seconds
Signal editing function
☞
Normal
(signal screen)
☞
Program
Action
Startup procedure
After mechanical and electrical installation, start-up, then
the device performs a selftest and is ready for use.
WIZARD
10
The Wizard automatically displays parameter setup steps
on-screen.
HELP
10 sec
ERROR
If false parameter value is inputted (e.g. outside limits) an error
message / icon occurs, and after
10 seconds the screen switches
to HELP function.
If error persists, download log file
using PACTware and send to email address given on back rear
page. For further information see
PACTware handbook on CD-ROM.
Setup procedure
Press 3 sec
Normal Mode
Program Mode
Complete
Installation
Quick setup
Empty Spectrum
Test
Advanced setup
Conversion
Service
Output
11
Quick links
Quick link #1
The customer can assign
any menu point to one of
the quick links (including
overwriting factory presets)
to avoid going through full
setup proce-dure.
Quick link #2
Quick link #3
Quick link #4
Quick link #5
Access to default or user-defined functions
Setup procedure
1. Installation type
2. Tank height
3. Measuring range
4. Application type
5. Stillwell diameter*
6. Blocking distance
7. Settings summary
8. Save ?
*if stillwell selected in step 4
1.
2.
3.
4.
5.
6.
7.
Calculation will not work if tank full. Continue ?
Are all moving parts on?
Is tank partially filled or empty ?
Level measurement value. Edit ?
Start recording
Display calculated spectrum
Save ?
1.
2.
3.
4.
5.
6.
7.
8.
Output 1 (Hart)
4 mA setting
20 mA setting
Output range
Error handling
HART address
Settings summary
Save?
Full details see
handbook on
CD-ROM
12
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
Conversion wizard type
Length unit
Density of product 1 (yes or no)
Density unit and value
Tank shape
Sphere Diameter
Tank Bottom Shape
Tank Diameter (Cyllindrical)
Tank Height (Cyllindrcal)
Tank Height 1 (Rectangular with Conical end)
Tank Height 2 (Rectangular with Conical end)
Tank Width (Rectangular with Conical end)
Tank Depth (Rectangular with Conical end)
Cone Depth (Rectangular with Conical end)
Tank Diameter (Cyllindrical with Conical end)
Tank Height 1 (Cyllindrical with Conical end)
Tank Height 2 (Cyllindrical with Conical end)
Cone Diameter (Cyllindrical with Conical end)
Tank Depth (Rectangular)
Tank Width (Rectangular)
Tank Height (Rectangular)
Angle of inclination X degrees
Conversion unit
Volume table values. Edit, save and exit setup (29)
Mass values. Save and exit the setup (29)
Length free unit name
Conversion free unit name
Enter free unit values, save and exit the setup (29)
Exit Setup

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2004:03:28 16:35:25Z
Modify Date                     : 2004:03:30 11:46:44+03:00
Creator                         : QuarkXPress(R) 3.32
Page Count                      : 12
Creation Date                   : 2004:03:28 16:35:25Z
Mod Date                        : 2004:03:30 11:46:44+03:00
Producer                        : Acrobat Distiller 5.0.5 f.r Macintosh
Metadata Date                   : 2004:03:30 11:46:44+03:00
Title                           : aussen 6 x A5 (Page 6)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JH5-OPTIWAVE7300C

Navigation menu