Kamstrup A S FLOWX250 flowIQ 2250 or flowIQ 3250 User Manual user man 3250
Kamstrup A/S flowIQ 2250 or flowIQ 3250 user man 3250
Contents
- 1. user man 2250
- 2. user man 3250
user man 3250
Optical eye for reading and configuration Digital display showing consumption and billing in 100s of ft3 Optional customer label, (not an option for Encoded Output version) Bar code with serial number, extended availability and production year Nominal meter size Max. flow for continous operation Toggle between volume, flow and SW version via fingertouch Type number (includes information on meter size, overall length etc.) Maximum admissible pressure FCC identification Temperature range Protection Class IP68 (Waterproof/submersible) Mounting of antenna Step 1: Push the base of the helix antenna through the seal housing. Step 2: Align the antenna by using the terminals and steering pin before clicking it into place. Note: The antenna must only be mounted on the meter with the antenna pointing upwards. Make sure the terminal is dry and clean before clicking the antenna into place. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. RF Exposure compliance statement: This device may be used with no restrictions, since the source-based time-averaged output power is ≤ 60/f(GHz) mW. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1 This device may not cause harmful interfenrence, and 2 This device must accept any interference received, including interference that may cause undesired operation. FCC Cautions The adjacent piping must be parallel and match the meter in- and outlet. flowIQ® 3250 Kamstrup A/S • DRAFT_55122150_B1_US_fccID_08.2017 Installation guide 1 General information Read this guide before installing the water meter. flowIQ® 3250 is a compact electronic water meter used for water consumption measurement in the tap water supplies of homes, commercial and industrial buildings. flowIQ® 3250 is hermetically closed, and it is, therefore, impossible to service the meter without breaking the seal. This means that all service, must be carried out by an authorized Kamstrup Service Centre. Certain changes of configuration, however, are possible via the built-in optical eye without dismounting the meter from the installation. Further details appear in the data sheet. 1.1 Permissible operating conditions/measuring ranges Fluid temperature: - 2 part body meter: Pressure stage: Mechanical environment: Electromagnetic environmental class: Protection class: Climatic environment: 33 °F...120 °F 250 PSI Fixed installation with minimum vibration. Residential and commercial IP68-rated (waterproof-submersible) 35 °F...140 °F. Condensing humidity. (indoors mounted in utility rooms and outdoors in meter pits). Installation in direct sunlight must be avoided. The meter must be protected from freezing as well. Service When the meter has been mounted in the system neither welding nor freezing is allowed. Dismount the meter from the system before starting such work. In order to facilitate replacement of the meter, shut off valves should be mounted on either side of the meter. Under normal operating conditions no pipe strainer is required in front of the meter. Check valves must be mounted in accordance with local regulations. 1.3 Installation angle of flowIQ® 3250 flowIQ® 3250 can be mounted at all angles and positions. Kamstrup Headquarters recommend that the display is mounted so that it is easy to read, if possible. Thus, the meter can be mounted in a plain horizontal installation. It can be mounted vertically on an ascending pipe, it can be mounted at any angle and it can be mounted with the display pointing downwards, e.g under a roof. Recommended water meter position. Recommended water meter position. Used for ‘pit installation’. Air ‘build-up’ may occur. The meter functions optimally, but the display is ’upside down’. 1.4 Straight inlet Please check that stop valves are tight and operate as intended and that the pipe system is without corrosion and damages. Damaged components, if any, must be replaced. 1.5 Operating pressure Having assembled the pipe system, all sealing surfaces of existing couplings must be cleaned to remove possible remaining pieces of gasket. Remove adhesive wafers from the meter’s inlet and outlet and mount the meter. Always use new gaskets in original quality. The flow direction is indicated by an arrow on the meter. Install the meter with an orientation that makes it easy for the consumer to read the display. During installation it must be secured that the meter is mounted without mechanical bias in the connection pipes. Do not attempt to correct oblique piping by means of the meter. At the same time make sure that the threaded length of the couplings does not prevent proper tightening of the sealing surface and that couplings with similar pressure ratings are used.If meters are mounted in meter pits or outdoors, both the meter pit and the meter must be protected against freezing. The table below describes the different info codes in the display. Info code flashes in the Meaning display Flow The three segments will switch on alternately to indicate flow in the meter Backflow Indication if there is reverse flow Leak The water has not been stagnant in the meter during the past 24 hours. This can be a sign of a leaky faucet or toilet. The water flow has exceeded a preprogrammed limit for a minimum of 30 minutes, which is a sign of a burst pipe. The meter is not water-filled. Dry 1.2 Installation requirements Close the main stop valve in front of the meter and let a tap run until the pressure in the system has been equalized. Close the stop valve after the meter before disassembling the pipe system. When flowIQ® 3250 leaves Kamstrup Headquarters, it has been tested and verified and the counter has been reset. The number of gallons or cu ft are displayed by nine large digits. Bars over and under each digit are fully customizable, meaning that they can be used to indicate numbers after the decimal point or indicate if the customer is billed in e.g. tens or hundreds of gallons. Burst Prior to installation of flowIQ® 3250, the system should be flushed while a fitting piece replaces the meter. 1.6 Info codes and display flowIQ® 3250 requires neither straight inlet nor straight outlet to meet applicable AWWA standards. A straight inlet section will only be necessary in case of heavy flow disturbances before the meter. In order to avoid cavitation and secure correct measurement under all circumstances the operating pressure in the pipe installation should observe the test conditions of AWWA M6 manual. The static pressure, immediately after the meter (downstream), must always be minimum 20 PSI (1.4 bar). Tamper Attempt of fraud. The meter is no longer valid for billing purposes. Radio OFF Flow unit The meter is still in transport mode with the built-in radio transmitter turned off. The transmitter turns on automatically when the frst 1/4 gallon of water has run though the meter. Indicates the configured flow unit. Battery Indication of the battery state. Active meter indication Meter adjustment A small square is flashing to indicate that the meter is active. If the meter has been dismounted, tested and the basic flow measurement has been adjusted this info code will appear.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2017:08:29 08:24:59+02:00 Creator : Adobe InDesign CC 2017 (Windows) Modify Date : 2017:08:29 08:25:19+02:00 Has XFA : No Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Metadata Date : 2017:08:29 08:25:19+02:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:4bc8a2ea-b6fa-4e26-b3b2-e0bba1d4d17b Original Document ID : xmp.did:CE01E6A1DFEFE0118D6AC478EE4E4D07 Document ID : xmp.id:bce494e6-6567-e041-bb97-c978619090e8 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:39d74e4d-212a-4241-93c7-be9a5c5243ee Derived From Document ID : xmp.did:eab60ae7-fcef-f54f-ac55-8760e167ea50 Derived From Original Document ID: xmp.did:CE01E6A1DFEFE0118D6AC478EE4E4D07 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:08:29 08:24:59+02:00 Canto Metadata : (Binary data 1267976 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Layout : SinglePage Page Count : 2 Signing Date : 2017:08:29 08:25:19+02:00 Signing Authority : ARE Acrobat Product v8.0 P23 0002337 Annotation Usage Rights : Create, Delete, Modify, Copy, Import, ExportEXIF Metadata provided by EXIF.tools